Sample records for cycle threshold ct

  1. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedam, S.; Archambault, L.; Starkschall, G.

    2007-11-15

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the deliverymore » gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation and delivery gate thresholds to within 0.3%. For patient data analysis, differences between simulation and delivery gate thresholds are reported as a fraction of the total respiratory motion range. For the smaller phase interval, the differences between simulation and delivery gate thresholds are 8{+-}11% and 14{+-}21% with and without audio-visual biofeedback, respectively, when the simulation gate threshold is determined based on the mean respiratory displacement within the 40%-60% gating phase interval. For the longer phase interval, corresponding differences are 4{+-}7% and 8{+-}15% with and without audio-visual biofeedback, respectively. Alternatively, when the simulation gate threshold is determined based on the maximum average respiratory displacement within the gating phase interval, greater differences between simulation and delivery gate thresholds are observed. A relationship between retrospective simulation gate threshold and prospective delivery gate threshold for respiratory gating is established and validated for regular and nonregular respiratory motion. Using this relationship, the delivery gate threshold can be reliably estimated at the time of 4D CT simulation, thereby improving the accuracy and efficiency of respiratory-gated radiation delivery.« less

  2. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation.

    PubMed

    Vedam, S; Archambault, L; Starkschall, G; Mohan, R; Beddar, S

    2007-11-01

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the delivery gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation and delivery gate thresholds to within 0.3%. For patient data analysis, differences between simulation and delivery gate thresholds are reported as a fraction of the total respiratory motion range. For the smaller phase interval, the differences between simulation and delivery gate thresholds are 8 +/- 11% and 14 +/- 21% with and without audio-visual biofeedback, respectively, when the simulation gate threshold is determined based on the mean respiratory displacement within the 40%-60% gating phase interval. For the longer phase interval, corresponding differences are 4 +/- 7% and 8 +/- 15% with and without audiovisual biofeedback, respectively. Alternatively, when the simulation gate threshold is determined based on the maximum average respiratory displacement within the gating phase interval, greater differences between simulation and delivery gate thresholds are observed. A relationship between retrospective simulation gate threshold and prospective delivery gate threshold for respiratory gating is established and validated for regular and nonregular respiratory motion. Using this relationship, the delivery gate threshold can be reliably estimated at the time of 4D CT simulation, thereby improving the accuracy and efficiency of respiratory-gated radiation delivery.

  3. The Purpose of Generating Fatigue Crack Growth Threshold Data

    NASA Technical Reports Server (NTRS)

    Forth, Scott

    2006-01-01

    Test data shows that different width and thickness C(T), M(T) and ESE(T) specimens generate different thresholds Structures designed for "infinite life" are being re-evaluated: a) Threshold changes from 6 to 3 ksi in(sup 1/2); b) Computational life changes from infinite to 4 missions. Multi-million dollar test programs required to substantiate operation. Using ASTM E647 as standard guidance to generate threshold data is not practical. A threshold test approach needs to be standardized that will provide positive margin for high cycle fatigue applications.

  4. Influence of technical parameters on epicardial fat volume quantification at cardiac CT.

    PubMed

    Bucher, Andreas M; Joseph Schoepf, U; Krazinski, Aleksander W; Silverman, Justin; Spearman, James V; De Cecco, Carlo N; Meinel, Felix G; Vogl, Thomas J; Geyer, Lucas L

    2015-06-01

    To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, P<0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each P<0.001). Bias values from Bland Altman Analysis were: CTAS15-CTAD15, 4.9%; CTAD15-CaScD45, -4.3%; CTAS15-CaScD45, 0.6%. Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Relationship Between Ebola Virus Real-Time Quantitative Polymerase Chain Reaction-Based Threshold Cycle Value and Virus Isolation From Human Plasma.

    PubMed

    Spengler, Jessica R; McElroy, Anita K; Harmon, Jessica R; Ströher, Ute; Nichol, Stuart T; Spiropoulou, Christina F

    2015-10-01

    We performed a longitudinal analysis of plasma samples obtained from 4 patients with Ebola virus (EBOV) disease (EVD) to determine the relationship between the real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR)-based threshold cycle (Ct) value and the presence of infectious EBOV. EBOV was not isolated from plasma samples with a Ct value of >35.5 or >12 days after onset of symptoms. EBOV was not isolated from plasma samples in which anti-EBOV nucleoprotein immunoglobulin G was detected. These data demonstrate the utility of interpreting qRT-PCR results in the context of the course of EBOV infection and associated serological responses for patient-management decisions. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  6. Assessment of real-time PCR cycle threshold values in Microsporum canis culture-positive and culture-negative cats in an animal shelter: a field study.

    PubMed

    Jacobson, Linda S; McIntyre, Lauren; Mykusz, Jenny

    2018-02-01

    Objectives Real-time PCR provides quantitative information, recorded as the cycle threshold (Ct) value, about the number of organisms detected in a diagnostic sample. The Ct value correlates with the number of copies of the target organism in an inversely proportional and exponential relationship. The aim of the study was to determine whether Ct values could be used to distinguish between culture-positive and culture-negative samples. Methods This was a retrospective analysis of Ct values from dermatophyte PCR results in cats with suspicious skin lesions or suspected exposure to dermatophytosis. Results One hundred and thirty-two samples were included. Using culture as the gold standard, 28 were true positives, 12 were false positives and 92 were true negatives. The area under the curve for the pretreatment time point was 96.8% (95% confidence interval [CI] 94.2-99.5) compared with 74.3% (95% CI 52.6-96.0) for pooled data during treatment. Before treatment, a Ct cut-off of <35.7 (approximate DNA count 300) provided a sensitivity of 92.3% and specificity of 95.2%. There was no reliable cut-off Ct value between culture-positive and culture-negative samples during treatment. Ct values prior to treatment differed significantly between the true-positive and false-positive groups ( P = 0.0056). There was a significant difference between the pretreatment and first and second negative culture time points ( P = 0.0002 and P <0.0001, respectively). However, there was substantial overlap between Ct values for true positives and true negatives, and for pre- and intra-treatment time points. Conclusions and relevance Ct values had limited usefulness for distinguishing between culture-positive and culture-negative cases when field study samples were analyzed. In addition, Ct values were less reliable than fungal culture for determining mycological cure.

  7. MPN estimation of qPCR target sequence recoveries from whole cell calibrator samples

    EPA Science Inventory

    DNA extracts from enumerated target organism cells (calibrator samples) have been used for estimating Enterococcus cell equivalent densities in surface waters by a comparative cycle threshold (Ct) qPCR analysis method. To compare surface water Enterococcus density estimates from ...

  8. Rapid and Accurate Diagnosis Based on Real-Time PCR Cycle Threshold Value for the Identification of Campylobacter jejuni, astA Gene-Positive Escherichia coli, and eae Gene-Positive E. coli.

    PubMed

    Kawase, Jun; Asakura, Hiroshi; Kurosaki, Morito; Oshiro, Hitoshi; Etoh, Yoshiki; Ikeda, Tetsuya; Watahiki, Masanori; Kameyama, Mitsuhiro; Hayashi, Fumi; Kawakami, Yuta; Murakami, Yoshiko; Tsunomori, Yoshie

    2018-01-23

    We previously developed a multiplex real-time PCR assay (Rapid Foodborne Bacterial Screening 24 ver.5, [RFBS24 ver.5]) for simultaneous detection of 24 foodborne bacterial targets. Here, to overcome the discrepancy of the results from RFBS24 ver.5 and bacterial culture methods (BC), we analyzed 246 human clinical samples from 49 gastroenteritis outbreaks using RFBS24 ver.5 and evaluated the correlation between the cycle threshold (CT) value of RFBS24 ver.5 and the BC results. The results showed that the RFBS24 ver.5 was more sensitive than BC for Campylobacter jejuni and Escherichia coli harboring astA or eae, with positive predictive values (PPV) of 45.5-87.0% and a kappa coefficient (KC) of 0.60-0.92, respectively. The CTs were significantly different between BC-positive and -negative samples (p < 0.01). All RFBS24 ver.5-positive samples were BC-positive under the lower confidence interval (CI) limit of 95% or 99% for the CT of the BC-negative samples. We set the 95% or 99% CI lower limit to the determination CT (d-CT) to discriminate for assured BC-positive results (d-CTs: 27.42-30.86), and subsequently the PPVs (94.7%-100.0%) and KCs (0.89-0.95) of the 3 targets were increased. Together, we concluded that the implication of a d-CT-based approach would be a valuable tool for rapid and accurate diagnoses using the RFBS24 ver.5 system.

  9. The impact of manual threshold selection in medical additive manufacturing.

    PubMed

    van Eijnatten, Maureen; Koivisto, Juha; Karhu, Kalle; Forouzanfar, Tymour; Wolff, Jan

    2017-04-01

    Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). The intra- and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-energy CT), and 0.55 mm (cone-beam CT). All STL models demonstrated inaccuracies ranging from -0.8 to +1.1 mm (multi-detector row CT), -0.7 to +2.0 mm (dual-energy CT), and -2.3 to +4.8 mm (cone-beam CT). This study demonstrates that manual threshold selection results in better STL models than default thresholding. The use of dual-energy CT and cone-beam CT technology in its present form does not deliver reliable or accurate STL models for medical additive manufacturing. New approaches are required that are based on pattern recognition and machine learning algorithms.

  10. Cost-utility comparison of neoadjuvant chemotherapy versus primary debulking surgery for treatment of advanced-stage ovarian cancer in patients 65 years old or older.

    PubMed

    Rowland, Michelle R; Lesnock, Jamie L; Farris, Coreen; Kelley, Joseph L; Krivak, Thomas C

    2015-06-01

    Treatment for advanced-stage epithelial ovarian cancer (AEOC) includes primary debulking surgery (PDS) or neoadjuvant chemotherapy (NACT). A randomized controlled trial comparing these treatments resulted in comparable overall survival (OS). Studies report more complications and lower chemotherapy completion rates in patients 65 years old or older receiving PDS. We sought to evaluate the cost implications of NACT relative to PDS in AEOC patients 65 years old or older. A 5 year Markov model was created. Arm 1 modeled PDS followed by 6 cycles of carboplatin and paclitaxel (CT). Arm 2 modeled 3 cycles of CT, followed by interval debulking surgery and then 3 additional cycles of CT. Parameters included OS, surgical complications, probability of treatment initiation, treatment cost, and quality of life (QOL). OS was assumed to be equal based on the findings of the international randomized control trial. Differences in surgical complexity were accounted for in base surgical cost plus add-on procedure costs weighted by occurrence rates. Hospital cost was a weighted average of diagnosis-related group costs weighted by composite estimates of complication rates. Sensitivity analyses were performed. Assuming equal survival, NACT produces a cost savings of $5616. If PDS improved median OS by 1.5 months or longer, PDS would be cost effective (CE) at a $100,000/quality-adjusted life-year threshold. If PDS improved OS by 3.2 months or longer, it would be CE at a $50,000 threshold. The model was robust to variation in costs and complication rates. Moderate decreases in the QOL with NACT would result in PDS being CE. A model based on the RCT comparing NACT and PDS showed NACT is a cost-saving treatment compared with PDS for AEOC in patients 65 years old or older. Small increases in OS with PDS or moderate declines in QOL with NACT would result in PDS being CE at the $100,000/quality-adjusted life-year threshold. Our results support further evaluation of the effects of PDS on OS, QOL and complications in AEOC patients 65 years old or older. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xiaohua; Yuan, Huishu; Duan, Jianghui

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lungmore » function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.« less

  12. Principal component analysis of the CT density histogram to generate parametric response maps of COPD

    NASA Astrophysics Data System (ADS)

    Zha, N.; Capaldi, D. P. I.; Pike, D.; McCormack, D. G.; Cunningham, I. A.; Parraga, G.

    2015-03-01

    Pulmonary x-ray computed tomography (CT) may be used to characterize emphysema and airways disease in patients with chronic obstructive pulmonary disease (COPD). One analysis approach - parametric response mapping (PMR) utilizes registered inspiratory and expiratory CT image volumes and CT-density-histogram thresholds, but there is no consensus regarding the threshold values used, or their clinical meaning. Principal-component-analysis (PCA) of the CT density histogram can be exploited to quantify emphysema using data-driven CT-density-histogram thresholds. Thus, the objective of this proof-of-concept demonstration was to develop a PRM approach using PCA-derived thresholds in COPD patients and ex-smokers without airflow limitation. Methods: Fifteen COPD ex-smokers and 5 normal ex-smokers were evaluated. Thoracic CT images were also acquired at full inspiration and full expiration and these images were non-rigidly co-registered. PCA was performed for the CT density histograms, from which the components with the highest eigenvalues greater than one were summed. Since the values of the principal component curve correlate directly with the variability in the sample, the maximum and minimum points on the curve were used as threshold values for the PCA-adjusted PRM technique. Results: A significant correlation was determined between conventional and PCA-adjusted PRM with 3He MRI apparent diffusion coefficient (p<0.001), with CT RA950 (p<0.0001), as well as with 3He MRI ventilation defect percent, a measurement of both small airways disease (p=0.049 and p=0.06, respectively) and emphysema (p=0.02). Conclusions: PRM generated using PCA thresholds of the CT density histogram showed significant correlations with CT and 3He MRI measurements of emphysema, but not airways disease.

  13. Rapid Isolation and Detection for RNA Biomarkers for TBI Diagnostics

    DTIC Science & Technology

    2016-10-01

    address the qualitative result of PCR by choosing the threshold crossover cycle (CT) as a surrogate measure of the RNA/DNA originally in the sample ...include developing DEP techniques for isolation of cell-free (cf) RNA from glioblastoma exosomes and TBI samples (IRB dependent); methods for on... Sample to Answer diagnostics. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF

  14. Evaluation of a shortened QIAsymphony DNA extraction protocol for stool samples using a multiplex real-time PCR for the detection of enteric pathogens.

    PubMed

    van Zanten, E; Wisselink, G J; Stoll, S; Alvarez, R; Kooistra-Smid, A M D

    2011-02-01

    A shortened DNA extraction protocol for the QIAsymphony SP was evaluated by quantitative and qualitative comparison of real-time PCR results of 150 co-extracted stool samples. The average ∆Cycle threshold value for positive pathogenic targets was 0.28 Ct. A consensus of 96.91%, with a correlation coefficient of 0.9880 was recorded. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Position-dependent effects of locked nucleic acid (LNA) on DNA sequencing and PCR primers

    PubMed Central

    Levin, Joshua D.; Fiala, Dean; Samala, Meinrado F.; Kahn, Jason D.; Peterson, Raymond J.

    2006-01-01

    Genomes are becoming heavily annotated with important features. Analysis of these features often employs oligonucleotides that hybridize at defined locations. When the defined location lies in a poor sequence context, traditional design strategies may fail. Locked Nucleic Acid (LNA) can enhance oligonucleotide affinity and specificity. Though LNA has been used in many applications, formal design rules are still being defined. To further this effort we have investigated the effect of LNA on the performance of sequencing and PCR primers in AT-rich regions, where short primers yield poor sequencing reads or PCR yields. LNA was used in three positional patterns: near the 5′ end (LNA-5′), near the 3′ end (LNA-3′) and distributed throughout (LNA-Even). Quantitative measures of sequencing read length (Phred Q30 count) and real-time PCR signal (cycle threshold, CT) were characterized using two-way ANOVA. LNA-5′ increased the average Phred Q30 score by 60% and it was never observed to decrease performance. LNA-5′ generated cycle thresholds in quantitative PCR that were comparable to high-yielding conventional primers. In contrast, LNA-3′ and LNA-Even did not improve read lengths or CT. ANOVA demonstrated the statistical significance of these results and identified significant interaction between the positional design rule and primer sequence. PMID:17071964

  16. Determination of a Testing Threshold for Lumbar Puncture in the Diagnosis of Subarachnoid Hemorrhage after a Negative Head Computed Tomography: A Decision Analysis.

    PubMed

    Taylor, Richard Andrew; Singh Gill, Harman; Marcolini, Evie G; Meyers, H Pendell; Faust, Jeremy Samuel; Newman, David H

    2016-10-01

    The objective was to determine the testing threshold for lumbar puncture (LP) in the evaluation of aneurysmal subarachnoid hemorrhage (SAH) after a negative head computed tomography (CT). As a secondary aim we sought to identify clinical variables that have the greatest impact on this threshold. A decision analytic model was developed to estimate the testing threshold for patients with normal neurologic findings, being evaluated for SAH, after a negative CT of the head. The testing threshold was calculated as the pretest probability of disease where the two strategies (LP or no LP) are balanced in terms of quality-adjusted life-years. Two-way and probabilistic sensitivity analyses (PSAs) were performed. For the base-case scenario the testing threshold for performing an LP after negative head CT was 4.3%. Results for the two-way sensitivity analyses demonstrated that the test threshold ranged from 1.9% to 15.6%, dominated by the uncertainty in the probability of death from initial missed SAH. In the PSA the mean testing threshold was 4.3% (95% confidence interval = 1.4% to 9.3%). Other significant variables in the model included probability of aneurysmal versus nonaneurysmal SAH after negative head CT, probability of long-term morbidity from initial missed SAH, and probability of renal failure from contrast-induced nephropathy. Our decision analysis results suggest a testing threshold for LP after negative CT to be approximately 4.3%, with a range of 1.4% to 9.3% on robust PSA. In light of these data, and considering the low probability of aneurysmal SAH after a negative CT, classical teaching and current guidelines addressing testing for SAH should be revisited. © 2016 by the Society for Academic Emergency Medicine.

  17. Near-threshold fatigue crack behaviour in EUROFER 97 at different temperatures

    NASA Astrophysics Data System (ADS)

    Aktaa, J.; Lerch, M.

    2006-07-01

    The fatigue crack behaviour in EUROFER 97 was investigated at room temperature (RT), 300, 500 and 550 °C for the assessment of cracks in first wall structures built from EUROFER 97 of future fusion reactors. For this purpose, fatigue crack growth tests were performed using CT specimens with two R-ratios, R = 0.1 and R = 0.5 ( R is the load ratio with R = Fmin/ Fmax where Fmin and Fmax are the minimum and maximum applied loads within a cycle, respectively). Hence, fatigue crack threshold, fatigue crack growth behaviour in the near-threshold range and their dependences on temperature and R-ratio were determined and described using an analytical formula. The fatigue crack threshold showed a monotonous dependence on temperature which is for R = 0.5 insignificantly small. The fatigue crack growth behaviour exhibited for R = 0.1 a non-monotonous dependence on temperature which is explained by the decrease of yield stress and the increase of creep damage with increasing temperature.

  18. Evaluation of bone formation in calcium phosphate scaffolds with μCT-method validation using SEM.

    PubMed

    Lewin, S; Barba, A; Persson, C; Franch, J; Ginebra, M-P; Öhman-Mägi, C

    2017-10-05

    There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography (μCT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μCT images. Commonly, segmentation of bone in μCT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μCT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μCT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μCT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in CaP scaffolds.

  19. Evaluation of Daphnid Grazing on Microscopic Zoosporic Fungi by Using Comparative Threshold Cycle Quantitative PCR

    PubMed Central

    Maier, Michelle A.; Uchii, Kimiko; Peterson, Tawnya D.

    2016-01-01

    ABSTRACT Lethal parasitism of large phytoplankton by chytrids (microscopic zoosporic fungi) may play an important role in organic matter and nutrient cycling in aquatic environments by shunting carbon away from hosts and into much smaller zoospores, which are more readily consumed by zooplankton. This pathway provides a mechanism to more efficiently retain carbon within food webs and reduce export losses. However, challenges in accurate identification and quantification of chytrids have prevented a robust assessment of the relative importance of parasitism for carbon and energy flows within aquatic systems. The use of molecular techniques has greatly advanced our ability to detect small, nondescript microorganisms in aquatic environments in recent years, including chytrids. We used quantitative PCR (qPCR) to quantify the consumption of zoospores by Daphnia in laboratory experiments using a culture-based comparative threshold cycle (CT) method. We successfully quantified the reduction of zoospores in water samples during Daphnia grazing and confirmed the presence of chytrid DNA inside the daphnid gut. We demonstrate that comparative CT qPCR is a robust and effective method to quantify zoospores and evaluate zoospore grazing by zooplankton and will aid in better understanding how chytrids contribute to organic matter cycling and trophic energy transfer within food webs. IMPORTANCE The study of aquatic fungi is often complicated by the fact that they possess complex life cycles that include a variety of morphological forms. Studies that rely on morphological characteristics to quantify the abundances of all stages of the fungal life cycle face the challenge of correctly identifying and enumerating the nondescript zoospores. These zoospores, however, provide an important trophic link between large colonial phytoplankton and zooplankton: that is, once the carbon is liberated from phytoplankton into the parasitic zoospores, the latter are consumed by zooplankton and carbon is retained in the aquatic food web rather than exported from the system. This study provides a tool to quantify zoospores and evaluate the consumption of zoospores by zooplankton in order to further our understanding of their role in food web dynamics. PMID:27107112

  20. Evaluation of Daphnid Grazing on Microscopic Zoosporic Fungi by Using Comparative Threshold Cycle Quantitative PCR.

    PubMed

    Maier, Michelle A; Uchii, Kimiko; Peterson, Tawnya D; Kagami, Maiko

    2016-07-01

    Lethal parasitism of large phytoplankton by chytrids (microscopic zoosporic fungi) may play an important role in organic matter and nutrient cycling in aquatic environments by shunting carbon away from hosts and into much smaller zoospores, which are more readily consumed by zooplankton. This pathway provides a mechanism to more efficiently retain carbon within food webs and reduce export losses. However, challenges in accurate identification and quantification of chytrids have prevented a robust assessment of the relative importance of parasitism for carbon and energy flows within aquatic systems. The use of molecular techniques has greatly advanced our ability to detect small, nondescript microorganisms in aquatic environments in recent years, including chytrids. We used quantitative PCR (qPCR) to quantify the consumption of zoospores by Daphnia in laboratory experiments using a culture-based comparative threshold cycle (CT) method. We successfully quantified the reduction of zoospores in water samples during Daphnia grazing and confirmed the presence of chytrid DNA inside the daphnid gut. We demonstrate that comparative CT qPCR is a robust and effective method to quantify zoospores and evaluate zoospore grazing by zooplankton and will aid in better understanding how chytrids contribute to organic matter cycling and trophic energy transfer within food webs. The study of aquatic fungi is often complicated by the fact that they possess complex life cycles that include a variety of morphological forms. Studies that rely on morphological characteristics to quantify the abundances of all stages of the fungal life cycle face the challenge of correctly identifying and enumerating the nondescript zoospores. These zoospores, however, provide an important trophic link between large colonial phytoplankton and zooplankton: that is, once the carbon is liberated from phytoplankton into the parasitic zoospores, the latter are consumed by zooplankton and carbon is retained in the aquatic food web rather than exported from the system. This study provides a tool to quantify zoospores and evaluate the consumption of zoospores by zooplankton in order to further our understanding of their role in food web dynamics. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  1. [The register of activity at the Ebola treatment center in Forecariah (Guinea) from april 23 to june 5, 2015: analysis and thoughts].

    PubMed

    Gaüzère, B-A; Ouellet, I; Nottebrock, D; Nied, J-C; Beya-Kadiebwe, B; Camara, A K; Camara, D; Camara, M L M; Camara, M; Soumah, A; Tounkara, M K; Monteil, V; Camara, A; Bauffe, F; Camara, A; Camara, I B; Sissoko, D; Simon, B; Jaspard, M; Tran-Minh, T; L'Hériteau, F

    2016-10-01

    The register of activity at the Ebola Treatment Center (ETC) in Forecariah (Guinea), from April 23 to June 5, 2015 is presented for analysis. The viral load of each patient is evaluated by the cycle threshold (Ct). One hundred and thirty patients were seen in Triage at the ETC, of which 24 (18.5%) patients who failed to meet theWHO case criteria for viral hemorrhagic fever were excluded from admission to the ETC. Of the 106 patients admitted in the ETC, 72 (67.9%) were declared non-cases after the results of their two PCR (drawn 48 hours apart) tests were negative. Thirty-four patients were tested positive for Ebola virus disease (EVD): 19 women and 15 men (sex ratio: male/female = 0.78), mean age of 33.51 ± 20.1 years (extremes of 42 days to 70 years), of which six children were aged below 8 years. The median initial Ct value was 21.6 ± 6.3 cycles in this group. Enquiry into patient contacts was only able to identify actual contacts in 20 of these patients (58.8%). Thirteen patients were ultimately cured of EVD (six men and seven women) - with a median age of 31.8 years (extremes of 4 to 54 years). These patients presented on admission with a median Ct value of 21.88 ± 6.2 cycles (extremes of 17.6 to 31.7). Of the six children aged below 8 years, only one survived. Twenty-one patients (61.76%) with EVD died (9 men and 12 women) - median age, 34 ± 21 years (extremes of 42 days to 70 years). They presented on admission with a median Ct value of 18 ± 7 cycles (extremes of 12 to 24). The single most important factor associated with lethality was the Ct value at the time of admission to the ETC (P = 0.0004), i.e., the lower the Ct value, the higher the lethality rate or simply stated, the higher the viral load, the greater the lethality. Age, sex, identification of contact, and delay between the onset of symptoms and admission did not prove to be predictive of death outcome in our series.

  2. Computed Tomography Aortic Valve Calcium Scoring in Patients With Aortic Stenosis.

    PubMed

    Pawade, Tania; Clavel, Marie-Annick; Tribouilloy, Christophe; Dreyfus, Julien; Mathieu, Tiffany; Tastet, Lionel; Renard, Cedric; Gun, Mesut; Jenkins, William Steven Arthur; Macron, Laurent; Sechrist, Jacob W; Lacomis, Joan M; Nguyen, Virginia; Galian Gay, Laura; Cuéllar Calabria, Hug; Ntalas, Ioannis; Cartlidge, Timothy Robert Graham; Prendergast, Bernard; Rajani, Ronak; Evangelista, Arturo; Cavalcante, João L; Newby, David E; Pibarot, Philippe; Messika Zeitoun, David; Dweck, Marc R

    2018-03-01

    Computed tomography aortic valve calcium scoring (CT-AVC) holds promise for the assessment of patients with aortic stenosis (AS). We sought to establish the clinical utility of CT-AVC in an international multicenter cohort of patients. Patients with AS who underwent ECG-gated CT-AVC within 3 months of echocardiography were entered into an international, multicenter, observational registry. Optimal CT-AVC thresholds for diagnosing severe AS were determined in patients with concordant echocardiographic assessments, before being used to arbitrate disease severity in those with discordant measurements. In patients with long-term follow-up, we assessed whether CT-AVC thresholds predicted aortic valve replacement and death. In 918 patients from 8 centers (age, 77±10 years; 60% men; peak velocity, 3.88±0.90 m/s), 708 (77%) patients had concordant echocardiographic assessments, in whom CT-AVC provided excellent discrimination for severe AS (C statistic: women 0.92, men 0.89). Our optimal sex-specific CT-AVC thresholds (women 1377 Agatston unit and men 2062 Agatston unit) were nearly identical to those previously reported (women 1274 Agatston unit and men 2065 Agatston unit). Clinical outcomes were available in 215 patients (follow-up 1029 [126-2251] days). Sex-specific CT-AVC thresholds independently predicted aortic valve replacement and death (hazard ratio, 3.90 [95% confidence interval, 2.19-6.78]; P <0.001) after adjustment for age, sex, peak velocity, and aortic valve area. Among 210 (23%) patients with discordant echocardiographic assessments, there was considerable heterogeneity in CT-AVC scores, which again were an independent predictor of clinical outcomes (hazard ratio, 3.67 [95% confidence interval, 1.39-9.73]; P =0.010). Sex-specific CT-AVC thresholds accurately identify severe AS and provide powerful prognostic information. These findings support their integration into routine clinical practice. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01358513, NCT02132026, NCT00338676, NCT00647088, NCT01679431. © 2018 American Heart Association, Inc.

  3. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    NASA Astrophysics Data System (ADS)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CT (μCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  4. Accuracy of cancellous bone volume fraction measured by micro-CT scanning.

    PubMed

    Ding, M; Odgaard, A; Hvid, I

    1999-03-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner supplied algorithm (method I). A significant deviation of volume fraction from method I was found: both the y-intercept and the slope of the regression line were significantly different from those of the Archimedes-based volume fraction (p < 0.001). New individual thresholds were determined based on a calibration of volume fraction to the Archimedes-based volume fractions (method II). The mean thresholds of the two methods were applied to segment 20 randomly selected specimens. The results showed that volume fraction using the mean threshold of method I was underestimated by 4% (p = 0.001), whereas the mean threshold of method II yielded accurate values. The precision of the measurement was excellent. Our data show that care must be taken when applying thresholds in generating 3-D data, and that a fixed threshold may be used to obtain reliable volume fraction data. This fixed threshold may be determined from the Archimedes-based volume fraction of a subgroup of specimens. The threshold may vary between different materials, and so it should be determined whenever a study series is performed.

  5. Can a toxin gene NAAT be used to predict toxin EIA and the severity of Clostridium difficile infection?

    PubMed

    Garvey, Mark I; Bradley, Craig W; Wilkinson, Martyn A C; Holden, Elisabeth

    2017-01-01

    Diagnosis of C. difficile infection (CDI) is controversial because of the many laboratory methods available and their lack of ability to distinguish between carriage, mild or severe disease. Here we describe whether a low C. difficile toxin B nucleic acid amplification test (NAAT) cycle threshold (CT) can predict toxin EIA, CDI severity and mortality. A three-stage algorithm was employed for CDI testing, comprising a screening test for glutamate dehydrogenase (GDH), followed by a NAAT, then a toxin enzyme immunoassay (EIA). All diarrhoeal samples positive for GDH and NAAT between 2012 and 2016 were analysed. The performance of the NAAT CT value as a classifier of toxin EIA outcome was analysed using a ROC curve; patient mortality was compared to CTs and toxin EIA via linear regression models. A CT value ≤26 was associated with ≥72% toxin EIA positivity; applying a logistic regression model we demonstrated an association between low CT values and toxin EIA positivity. A CT value of ≤26 was significantly associated ( p  = 0.0262) with increased one month mortality, severe cases of CDI or failure of first line treatment. The ROC curve probabilities demonstrated a CT cut off value of 26.6. Here we demonstrate that a CT ≤26 indicates more severe CDI and is associated with higher mortality. Samples with a low CT value are often toxin EIA positive, questioning the need for this additional EIA test. A CT ≤26 could be used to assess the potential for severity of CDI and guide patient treatment.

  6. SART-Type Half-Threshold Filtering Approach for CT Reconstruction

    PubMed Central

    YU, HENGYONG; WANG, GE

    2014-01-01

    The ℓ1 regularization problem has been widely used to solve the sparsity constrained problems. To enhance the sparsity constraint for better imaging performance, a promising direction is to use the ℓp norm (0 < p < 1) and solve the ℓp minimization problem. Very recently, Xu et al. developed an analytic solution for the ℓ1∕2 regularization via an iterative thresholding operation, which is also referred to as half-threshold filtering. In this paper, we design a simultaneous algebraic reconstruction technique (SART)-type half-threshold filtering framework to solve the computed tomography (CT) reconstruction problem. In the medical imaging filed, the discrete gradient transform (DGT) is widely used to define the sparsity. However, the DGT is noninvertible and it cannot be applied to half-threshold filtering for CT reconstruction. To demonstrate the utility of the proposed SART-type half-threshold filtering framework, an emphasis of this paper is to construct a pseudoinverse transforms for DGT. The proposed algorithms are evaluated with numerical and physical phantom data sets. Our results show that the SART-type half-threshold filtering algorithms have great potential to improve the reconstructed image quality from few and noisy projections. They are complementary to the counterparts of the state-of-the-art soft-threshold filtering and hard-threshold filtering. PMID:25530928

  7. SART-Type Half-Threshold Filtering Approach for CT Reconstruction.

    PubMed

    Yu, Hengyong; Wang, Ge

    2014-01-01

    The [Formula: see text] regularization problem has been widely used to solve the sparsity constrained problems. To enhance the sparsity constraint for better imaging performance, a promising direction is to use the [Formula: see text] norm (0 < p < 1) and solve the [Formula: see text] minimization problem. Very recently, Xu et al. developed an analytic solution for the [Formula: see text] regularization via an iterative thresholding operation, which is also referred to as half-threshold filtering. In this paper, we design a simultaneous algebraic reconstruction technique (SART)-type half-threshold filtering framework to solve the computed tomography (CT) reconstruction problem. In the medical imaging filed, the discrete gradient transform (DGT) is widely used to define the sparsity. However, the DGT is noninvertible and it cannot be applied to half-threshold filtering for CT reconstruction. To demonstrate the utility of the proposed SART-type half-threshold filtering framework, an emphasis of this paper is to construct a pseudoinverse transforms for DGT. The proposed algorithms are evaluated with numerical and physical phantom data sets. Our results show that the SART-type half-threshold filtering algorithms have great potential to improve the reconstructed image quality from few and noisy projections. They are complementary to the counterparts of the state-of-the-art soft-threshold filtering and hard-threshold filtering.

  8. SU-E-J-242: Volume-Dependence of Quantitative Imaging Features From CT and CE-CT Images of NSCLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fave, X; Fried, D; UT Health Science Center Graduate School of Biomedical Sciences, Houston, TX

    Purpose: To determine whether tumor volume plays a significant role in the values obtained for texture features when they are extracted from computed tomography (CT) images of non-small cell lung cancer (NSCLC). We also sought to identify whether features can be reliably measured at all volumes or if a minimum volume threshold should be recommended. Methods: Eleven features were measured on 40 CT and 32 contrast-enhanced CT (CECT) patient images for this study. Features were selected for their prognostic/diagnostic value in previous publications. Direct correlations between these textures and volume were evaluated using the Spearman correlation coefficient. Any texture thatmore » the Wilcoxon rank-sum test was used to compare the variation above and below a volume cutoff. Four different volume thresholds (5, 10, 15, and 20 cm{sup 3}) were tested. Results: Four textures were found to be significantly correlated with volume in both the CT and CE-CT images. These were busyness, coarseness, gray-level nonuniformity, and run-length nonuniformity with correlation coefficients of 0.92, −0.96, 0.94, and 0.98 for the CT images and 0.95, −0.97, 0.98, and 0.98 for the CE-CT images. After volume normalization, the correlation coefficients decreased substantially. For the data obtained from the CT images, the results of the Wilcoxon rank-sum test were significant when volume thresholds of 5–15 cm3 were used. No volume threshold was shown to be significant for the CE-CT data. Conclusion: Equations for four features that have been used in several published studies were found to be volume-dependent. Future studies should consider implementing normalization factors or removing these features entirely to prevent this potential source of redundancy or bias. This work was supported in part by National Cancer Institute grant R03CA178495-01. Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.« less

  9. Error minimization algorithm for comparative quantitative PCR analysis: Q-Anal.

    PubMed

    OConnor, William; Runquist, Elizabeth A

    2008-07-01

    Current methods for comparative quantitative polymerase chain reaction (qPCR) analysis, the threshold and extrapolation methods, either make assumptions about PCR efficiency that require an arbitrary threshold selection process or extrapolate to estimate relative levels of messenger RNA (mRNA) transcripts. Here we describe an algorithm, Q-Anal, that blends elements from current methods to by-pass assumptions regarding PCR efficiency and improve the threshold selection process to minimize error in comparative qPCR analysis. This algorithm uses iterative linear regression to identify the exponential phase for both target and reference amplicons and then selects, by minimizing linear regression error, a fluorescence threshold where efficiencies for both amplicons have been defined. From this defined fluorescence threshold, cycle time (Ct) and the error for both amplicons are calculated and used to determine the expression ratio. Ratios in complementary DNA (cDNA) dilution assays from qPCR data were analyzed by the Q-Anal method and compared with the threshold method and an extrapolation method. Dilution ratios determined by the Q-Anal and threshold methods were 86 to 118% of the expected cDNA ratios, but relative errors for the Q-Anal method were 4 to 10% in comparison with 4 to 34% for the threshold method. In contrast, ratios determined by an extrapolation method were 32 to 242% of the expected cDNA ratios, with relative errors of 67 to 193%. Q-Anal will be a valuable and quick method for minimizing error in comparative qPCR analysis.

  10. Detection of West Nile virus lineage 2 in the urine of acute human infections.

    PubMed

    Papa, Anna; Testa, Theodolinda; Papadopoulou, Elpida

    2014-12-01

    West Nile virus (WNV) lineage 2 emerged in Greece in 2010 and since then outbreaks in humans have been reported for four consecutive years. Laboratory diagnosis is based mainly on serology. A real-time RT-PCR was applied on urine samples obtained from 35 patients with acute WNV infection. WNV RNA was detected in 40% of the samples with cycle threshold (CT) values ranging from 26.95 to 39.89 (mean 33.11). WNV was isolated from two of four urine samples with low CT (<30). Viral load was not associated with patients' age, sex, day of illness, presence of WNV antibodies, and neurological symptoms. However, it seems that sample shipment and storage conditions are very important for virus detection and isolation. The usefulness of the WNV RNA detection in urine as a diagnostic tool of acute WNV infections is discussed. © 2014 Wiley Periodicals, Inc.

  11. Comparison of epicardial adipose tissue radiodensity threshold between contrast and non-contrast enhanced computed tomography scans: A cohort study of derivation and validation.

    PubMed

    Xu, Lingyu; Xu, Yuancheng; Coulden, Richard; Sonnex, Emer; Hrybouski, Stanislau; Paterson, Ian; Butler, Craig

    2018-05-11

    Epicardial adipose tissue (EAT) volume derived from contrast enhanced (CE) computed tomography (CT) scans is not well validated. We aim to establish a reliable threshold to accurately quantify EAT volume from CE datasets. We analyzed EAT volume on paired non-contrast (NC) and CE datasets from 25 patients to derive appropriate Hounsfield (HU) cutpoints to equalize two EAT volume estimates. The gold standard threshold (-190HU, -30HU) was used to assess EAT volume on NC datasets. For CE datasets, EAT volumes were estimated using three previously reported thresholds: (-190HU, -30HU), (-190HU, -15HU), (-175HU, -15HU) and were analyzed by a semi-automated 3D Fat analysis software. Subsequently, we applied a threshold correction to (-190HU, -30HU) based on mean differences in radiodensity between NC and CE images (ΔEATrd = CE radiodensity - NC radiodensity). We then validated our findings on EAT threshold in 21 additional patients with paired CT datasets. EAT volume from CE datasets using previously published thresholds consistently underestimated EAT volume from NC dataset standard by a magnitude of 8.2%-19.1%. Using our corrected threshold (-190HU, -3HU) in CE datasets yielded statistically identical EAT volume to NC EAT volume in the validation cohort (186.1 ± 80.3 vs. 185.5 ± 80.1 cm 3 , Δ = 0.6 cm 3 , 0.3%, p = 0.374). Estimating EAT volume from contrast enhanced CT scans using a corrected threshold of -190HU, -3HU provided excellent agreement with EAT volume from non-contrast CT scans using a standard threshold of -190HU, -30HU. Copyright © 2018. Published by Elsevier B.V.

  12. Feasibility of spectral CT imaging for the detection of liver lesions with gold-based contrast agents - A simulation study.

    PubMed

    Müllner, Marie; Schlattl, Helmut; Hoeschen, Christoph; Dietrich, Olaf

    2015-12-01

    To demonstrate the feasibility of gold-specific spectral CT imaging for the detection of liver lesions in humans at low concentrations of gold as targeted contrast agent. A Monte Carlo simulation study of spectral CT imaging with a photon-counting and energy-resolving detector (with 6 energy bins) was performed in a realistic phantom of the human abdomen. The detector energy thresholds were optimized for the detection of gold. The simulation results were reconstructed with the K-edge imaging algorithm; the reconstructed gold-specific images were filtered and evaluated with respect to signal-to-noise ratio and contrast-to-noise ratio (CNR). The simulations demonstrate the feasibility of spectral CT with CNRs of the specific gold signal between 2.7 and 4.8 after bilateral filtering. Using the optimized bin thresholds increases the CNRs of the lesions by up to 23% compared to bin thresholds described in former studies. Gold is a promising new CT contrast agent for spectral CT in humans; minimum tissue mass fractions of 0.2 wt% of gold are required for sufficient image contrast. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Development of a thresholding algorithm for calcium classification at multiple CT energies

    NASA Astrophysics Data System (ADS)

    Ng, LY.; Alssabbagh, M.; Tajuddin, A. A.; Shuaib, I. L.; Zainon, R.

    2017-05-01

    The objective of this study was to develop a thresholding method for calcium classification with different concentration using single-energy computed tomography. Five different concentrations of calcium chloride were filled in PMMA tubes and placed inside a water-filled PMMA phantom (diameter 10 cm). The phantom was scanned at 70, 80, 100, 120 and 140 kV using a SECT. CARE DOSE 4D was used and the slice thickness was set to 1 mm for all energies. ImageJ software inspired by the National Institute of Health (NIH) was used to measure the CT numbers for each calcium concentration from the CT images. The results were compared with a developed algorithm for verification. The percentage differences between the measured CT numbers obtained from the developed algorithm and the ImageJ show similar results. The multi-thresholding algorithm was found to be able to distinguish different concentrations of calcium chloride. However, it was unable to detect low concentrations of calcium chloride and iron (III) nitrate with CT numbers between 25 HU and 65 HU. The developed thresholding method used in this study may help to differentiate between calcium plaques and other types of plaques in blood vessels as it is proven to have a good ability to detect the high concentration of the calcium chloride. However, the algorithm needs to be improved to solve the limitations of detecting calcium chloride solution which has a similar CT number with iron (III) nitrate solution.

  14. A Method for Application of Classification Tree Models to Map Aquatic Vegetation Using Remotely Sensed Images from Different Sensors and Dates

    PubMed Central

    Jiang, Hao; Zhao, Dehua; Cai, Ying; An, Shuqing

    2012-01-01

    In previous attempts to identify aquatic vegetation from remotely-sensed images using classification trees (CT), the images used to apply CT models to different times or locations necessarily originated from the same satellite sensor as that from which the original images used in model development came, greatly limiting the application of CT. We have developed an effective normalization method to improve the robustness of CT models when applied to images originating from different sensors and dates. A total of 965 ground-truth samples of aquatic vegetation types were obtained in 2009 and 2010 in Taihu Lake, China. Using relevant spectral indices (SI) as classifiers, we manually developed a stable CT model structure and then applied a standard CT algorithm to obtain quantitative (optimal) thresholds from 2009 ground-truth data and images from Landsat7-ETM+, HJ-1B-CCD, Landsat5-TM and ALOS-AVNIR-2 sensors. Optimal CT thresholds produced average classification accuracies of 78.1%, 84.7% and 74.0% for emergent vegetation, floating-leaf vegetation and submerged vegetation, respectively. However, the optimal CT thresholds for different sensor images differed from each other, with an average relative variation (RV) of 6.40%. We developed and evaluated three new approaches to normalizing the images. The best-performing method (Method of 0.1% index scaling) normalized the SI images using tailored percentages of extreme pixel values. Using the images normalized by Method of 0.1% index scaling, CT models for a particular sensor in which thresholds were replaced by those from the models developed for images originating from other sensors provided average classification accuracies of 76.0%, 82.8% and 68.9% for emergent vegetation, floating-leaf vegetation and submerged vegetation, respectively. Applying the CT models developed for normalized 2009 images to 2010 images resulted in high classification (78.0%–93.3%) and overall (92.0%–93.1%) accuracies. Our results suggest that Method of 0.1% index scaling provides a feasible way to apply CT models directly to images from sensors or time periods that differ from those of the images used to develop the original models.

  15. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    PubMed

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  16. Rainfall thresholds for forecasting landslides in the Seattle, Washington, area - exceedance and probability

    USGS Publications Warehouse

    Chleborad, Alan F.; Baum, Rex L.; Godt, Jonathan W.

    2006-01-01

    Empirical rainfall thresholds and related information form a basis for forecasting landslides in the Seattle area. A formula for a cumulative rainfall threshold (CT), P3=3.5-0.67P15, defined by rainfall amounts (in inches) during the last 3 days (72 hours), P3, and the previous 15 days (360 hours), P15, was developed from analysis of historical data for 91 landslides that occurred as part of 3-day events of three or more landslides between 1933 and 1997. Comparison with historical records for 577 landslides (including some used in developing the CT) indicates that the CT captures more than 90 percent of historical landslide events of three or more landslides in 1-day and 3-day periods that were recorded from 1978 to 2003. However, the probability of landslide occurrence on a day when the CT is exceeded at any single rain gage (8.4 percent) is low, and additional criteria are needed to confidently forecast landslide occurrence. Exceedance of a rainfall intensity-duration threshold I=3.257D-1.13, for intensity, I, (inch per hour) and duration, D, (hours), corresponds to a higher probability of landslide occurrence (42 percent at any 3 rain gages or 65 percent at any 10 rain gages), but it predicts fewer landslides. Both thresholds must be used in tandem to forecast landslide occurrence in Seattle.

  17. Molecular Mechanism for Prostate Cancer Resistance to the Anti-tumor Activity of Vitamin D

    DTIC Science & Technology

    2006-11-01

    point where each curve crossed the threshold line (Ct) using the following equation : Rel. value = 2[Ct(control) Ct(test)]test gene / 2[Ct(control...by hypermethylation in human pancreatic cancer. J Hum Genet 2005;50:159–67. 41. Armes JE, Hammet F, de Silva M, et al. Candidate tumor-suppressor...line (Ct) using the equation : Rel. Value = 2 - [Ct(control) – Ct(test)]test gene/ 2 -[Ct(control) – Ct(test)]housekeeping gene [22]. Reactions were

  18. Early PET/CT scan is more effective than RECIST in predicting outcome of patients with liver metastases from colorectal cancer treated with preoperative chemotherapy plus bevacizumab.

    PubMed

    Lastoria, Secondo; Piccirillo, Maria Carmela; Caracò, Corradina; Nasti, Guglielmo; Aloj, Luigi; Arrichiello, Cecilia; de Lutio di Castelguidone, Elisabetta; Tatangelo, Fabiana; Ottaiano, Alessandro; Iaffaioli, Rosario Vincenzo; Izzo, Francesco; Romano, Giovanni; Giordano, Pasqualina; Signoriello, Simona; Gallo, Ciro; Perrone, Francesco

    2013-12-01

    Markers predictive of treatment effect might be useful to improve the treatment of patients with metastatic solid tumors. Particularly, early changes in tumor metabolism measured by PET/CT with (18)F-FDG could predict the efficacy of treatment better than standard dimensional Response Evaluation Criteria In Solid Tumors (RECIST) response. We performed PET/CT evaluation before and after 1 cycle of treatment in patients with resectable liver metastases from colorectal cancer, within a phase 2 trial of preoperative FOLFIRI plus bevacizumab. For each lesion, the maximum standardized uptake value (SUV) and the total lesion glycolysis (TLG) were determined. On the basis of previous studies, a ≤ -50% change from baseline was used as a threshold for significant metabolic response for maximum SUV and, exploratively, for TLG. Standard RECIST response was assessed with CT after 3 mo of treatment. Pathologic response was assessed in patients undergoing resection. The association between metabolic and CT/RECIST and pathologic response was tested with the McNemar test; the ability to predict progression-free survival (PFS) and overall survival (OS) was tested with the Log-rank test and a multivariable Cox model. Thirty-three patients were analyzed. After treatment, there was a notable decrease of all the parameters measured by PET/CT. Early metabolic PET/CT response (either SUV- or TLG-based) had a stronger, independent and statistically significant predictive value for PFS and OS than both CT/RECIST and pathologic response at multivariate analysis, although with different degrees of statistical significance. The predictive value of CT/RECIST response was not significant at multivariate analysis. PET/CT response was significantly predictive of long-term outcomes during preoperative treatment of patients with liver metastases from colorectal cancer, and its predictive ability was higher than that of CT/RECIST response after 3 mo of treatment. Such findings need to be confirmed by larger prospective trials.

  19. Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study.

    PubMed

    Queiroz, Polyane Mazucatto; Rovaris, Karla; Santaella, Gustavo Machado; Haiter-Neto, Francisco; Freitas, Deborah Queiroz

    2017-01-01

    To calculate root canal volume and surface area in microCT images, an image segmentation by selecting threshold values is required, which can be determined by visual or automatic methods. Visual determination is influenced by the operator's visual acuity, while the automatic method is done entirely by computer algorithms. To compare between visual and automatic segmentation, and to determine the influence of the operator's visual acuity on the reproducibility of root canal volume and area measurements. Images from 31 extracted human anterior teeth were scanned with a μCT scanner. Three experienced examiners performed visual image segmentation, and threshold values were recorded. Automatic segmentation was done using the "Automatic Threshold Tool" available in the dedicated software provided by the scanner's manufacturer. Volume and area measurements were performed using the threshold values determined both visually and automatically. The paired Student's t-test showed no significant difference between visual and automatic segmentation methods regarding root canal volume measurements (p=0.93) and root canal surface (p=0.79). Although visual and automatic segmentation methods can be used to determine the threshold and calculate root canal volume and surface, the automatic method may be the most suitable for ensuring the reproducibility of threshold determination.

  20. Pitfalls in interpretation of CT-values of RT-PCR in children with acute respiratory tract infections.

    PubMed

    Wishaupt, Jérôme O; Ploeg, Tjeerd van der; Smeets, Leo C; Groot, Ronald de; Versteegh, Florens G A; Hartwig, Nico G

    2017-05-01

    The relation between viral load and disease severity in childhood acute respiratory tract infections (ARI) is not fully understood. To assess the clinical relevance of the relation between viral load, determined by cycle threshold (CT) value of real-time reverse transcription-polymerase chain reaction assays and disease severity in children with single- and multiple viral ARI. 582 children with ARI were prospectively followed and tested for 15 viruses. Correlations were calculated between CT values and clinical parameters. In single viral ARI, statistically significant correlations were found between viral loads of Respiratory Syncytial Virus (RSV) and hospitalization and between viral loads of Human Coronavirus (HCoV) and a disease severity score. In multiple-viral ARI, statistically significant correlations between viral load and clinical parameters were found. In RSV-Rhinovirus (RV) multiple infections, a low viral load of RV was correlated with a high length of hospital stay and a high duration of extra oxygen use. The mean CT value for RV, HCoV and Parainfluenza virus was significantly lower in single- versus multiple infections. Although correlations between CT values and clinical parameters in patients with single and multiple viral infection were found, the clinical importance of these findings is limited because individual differences in host-, viral and laboratory factors complicate the interpretation of statistically significant findings. In multiple infections, viral load cannot be used to differentiate between disease causing virus and innocent bystanders. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Correlation between PET/CT parameters and KRAS expression in colorectal cancer.

    PubMed

    Chen, Shang-Wen; Chiang, Hua-Che; Chen, William Tzu-Liang; Hsieh, Te-Chun; Yen, Kuo-Yang; Chiang, Shu-Fen; Kao, Chia-Hung

    2014-08-01

    The objective of this study was to correlate the association between mutated KRAS and wild-type colorectal cancer (CRC) by using various F-FDG PET-related parameters. One hundred twenty-one CRC patients who had undergone preoperative PET/CT were included in this study. Several PET/CT-related parameters, including SUVmax and various thresholds of metabolic tumor volume, total lesion glycolysis, and PET/CT-based tumor width, were measured. Tumor- and PET/CT-related parameters were correlated with genomic expression between KRAS mutant and wild-type groups, using a Mann-Whitney U test and logistic regression analysis. Colorectal cancer tumors with a mutated KRAS exhibited higher SUVmax and an increased accumulation of FDG among several threshold methods. Multivariate analysis showed that SUVmax and using a 40% threshold level for maximal uptake of TW (TW40%) were the 2 predictors of KRAS mutations. The odds ratio was 1.23 for SUVmax (P = 0.02; 95% confidence interval, 1.01-1.52) and 1.15 for TW40% (P = 0.02; 95% confidence interval, 1.02-1.30). The accuracy of SUVmax for predicting mutated KRAS was higher in patients with colon or sigmoid colon cancers, whereas it was TW40% in those with rectal cancers. SUVmax and TW40% were associated in CRC with KRAS mutations. PET/CT parameters can supplement genomic analysis to determine KRAS expression in CRC.

  2. ACR appropriateness criteria(®) on abnormal vaginal bleeding.

    PubMed

    Bennett, Genevieve L; Andreotti, Rochelle F; Lee, Susanna I; Dejesus Allison, Sandra O; Brown, Douglas L; Dubinsky, Theodore; Glanc, Phyllis; Mitchell, Donald G; Podrasky, Ann E; Shipp, Thomas D; Siegel, Cary Lynn; Wong-You-Cheong, Jade J; Zelop, Carolyn M

    2011-07-01

    In evaluating a woman with abnormal vaginal bleeding, imaging cannot replace definitive histologic diagnosis but often plays an important role in screening, characterization of structural abnormalities, and directing appropriate patient care. Transvaginal ultrasound (TVUS) is generally the initial imaging modality of choice, with endometrial thickness a well-established predictor of endometrial disease in postmenopausal women. Endometrial thickness measurements of ≤5 mm and ≤4 mm have been advocated as appropriate upper threshold values to reasonably exclude endometrial carcinoma in postmenopausal women with vaginal bleeding; however, the best upper threshold endometrial thickness in the asymptomatic postmenopausal patient remains a subject of debate. Endometrial thickness in a premenopausal patient is a less reliable indicator of endometrial pathology since this may vary widely depending on the phase of menstrual cycle, and an upper threshold value for normal has not been well-established. Transabdominal ultrasound is generally an adjunct to TVUS and is most helpful when TVUS is not feasible or there is poor visualization of the endometrium. Hysterosonography may also allow for better delineation of both the endometrium and focal abnormalities in the endometrial cavity, leading to hysteroscopically directed biopsy or resection. Color and pulsed Doppler may provide additional characterization of a focal endometrial abnormality by demonstrating vascularity. MRI may also serve as an important problem-solving tool if the endometrium cannot be visualized on TVUS and hysterosonography is not possible, as well as for pretreatment planning of patients with suspected endometrial carcinoma. CT is generally not warranted for the evaluation of patients with abnormal bleeding, and an abnormal endometrium incidentally detected on CT should be further evaluated with TVUS. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Appearance of bony lesions on 3-D CT reconstructions: a case study in variable renderings

    NASA Astrophysics Data System (ADS)

    Mankovich, Nicholas J.; White, Stuart C.

    1992-05-01

    This paper discusses conventional 3-D reconstruction for bone visualization and presents a case study to demonstrate the dangers of performing 3-D reconstructions without careful selection of the bone threshold. The visualization of midface bone lesions directly from axial CT images is difficult because of the complex anatomic relationships. Three-dimensional reconstructions made from the CT to provide graphic images showing lesions in relation to adjacent facial bones. Most commercially available 3-D image reconstruction requires that the radiologist or technologist identify a threshold image intensity value that can be used to distinguish bone from other tissues. Much has been made of the many disadvantages of this technique, but it continues as the predominant method in producing 3-D pictures for clinical use. This paper is intended to provide a clear demonstration for the physician of the caveats that should accompany 3-D reconstructions. We present a case of recurrent odontogenic keratocyst in the anterior maxilla where the 3-D reconstructions, made with different bone thresholds (windows), are compared to the resected specimen. A DMI 3200 computer was used to convert the scan data from a GE 9800 CT into a 3-D shaded surface image. Threshold values were assigned to (1) generate the most clinically pleasing image, (2) produce maximum theoretical fidelity (using the midpoint image intensity between average cortical bone and average soft tissue), and (3) cover stepped threshold intensities between these two methods. We compared the computer lesions with the resected specimen and noted measurement errors of up to 44 percent introduced by inappropriate bone threshold levels. We suggest clinically applicable standardization techniques in the 3-D reconstruction as well as cautionary language that should accompany the 3-D images.

  4. Impact of view reduction in CT on radiation dose for patients

    NASA Astrophysics Data System (ADS)

    Parcero, E.; Flores, L.; Sánchez, M. G.; Vidal, V.; Verdú, G.

    2017-08-01

    Iterative methods have become a hot topic of research in computed tomography (CT) imaging because of their capacity to resolve the reconstruction problem from a limited number of projections. This allows the reduction of radiation exposure on patients during the data acquisition. The reconstruction time and the high radiation dose imposed on patients are the two major drawbacks in CT. To solve them effectively we adapted the method for sparse linear equations and sparse least squares (LSQR) with soft threshold filtering (STF) and the fast iterative shrinkage-thresholding algorithm (FISTA) to computed tomography reconstruction. The feasibility of the proposed methods is demonstrated numerically.

  5. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, Y; Bowsher, J; Yan, S

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medicalmore » Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.« less

  6. Detection of Pneumocystis jirovecii by Quantitative PCR To Differentiate Colonization and Pneumonia in Immunocompromised HIV-Positive and HIV-Negative Patients

    PubMed Central

    Hasseine, L.; Gari-Toussaint, M.; Casanova, V.; Marty, P. M.; Pomares, C.

    2016-01-01

    Pneumocystis jirovecii pneumonia (PCP) is an acute and life-threatening lung disease caused by the fungus Pneumocystis jirovecii. The presentation of PCP in HIV-positive patients is well-known and consists of a triad of dyspnea, fever, and cough, whereas the presentation of PCP in HIV-negative patients is atypical and consists of a sudden outbreak, O2 desaturation, and a rapid lethal outcome without therapy. Despite the availability of direct and indirect identification methods, the diagnosis of PCP remains difficult. The cycle threshold (CT) values obtained by quantitative PCR (qPCR) allow estimation of the fungal burden. The more elevated that the fungal burden is, the higher the probability that the diagnosis is pneumonia. The purposes of the present study were to evaluate the CT values to differentiate colonization and pneumonia in a population of immunocompromised patients overall and patients stratified on the basis of their HIV infection status. Testing of bronchoalveolar lavage (BAL) fluid samples from the whole population of qPCR-positive patients showed a mean CT value for patients with PCP of 28 (95% confidence interval [CI], 26 to 30) and a mean CT value for colonized patients of 35 (95% CI, 34 to 36) (P < 10−3). For the subgroup of HIV-positive patients, we demonstrated that a CT value below 27 excluded colonization and a CT value above 30 excluded PCP with a specificity of 100% and a sensitivity of 80%, respectively. In the subgroup of HIV-negative patients, we demonstrated that a CT value below 31 excluded colonization and a CT value above 35 excluded PCP with a specificity of 80% and a sensitivity of 80%, respectively. Thus, qPCR of BAL fluid samples is an important tool for the differentiation of colonization and pneumonia in P. jirovecii-infected immunocompromised patients and patients stratified on the basis of HIV infection status with different CT values. PMID:27008872

  7. Detection of Pneumocystis jirovecii by Quantitative PCR To Differentiate Colonization and Pneumonia in Immunocompromised HIV-Positive and HIV-Negative Patients.

    PubMed

    Fauchier, T; Hasseine, L; Gari-Toussaint, M; Casanova, V; Marty, P M; Pomares, C

    2016-06-01

    Pneumocystis jirovecii pneumonia (PCP) is an acute and life-threatening lung disease caused by the fungus Pneumocystis jirovecii The presentation of PCP in HIV-positive patients is well-known and consists of a triad of dyspnea, fever, and cough, whereas the presentation of PCP in HIV-negative patients is atypical and consists of a sudden outbreak, O2 desaturation, and a rapid lethal outcome without therapy. Despite the availability of direct and indirect identification methods, the diagnosis of PCP remains difficult. The cycle threshold (CT) values obtained by quantitative PCR (qPCR) allow estimation of the fungal burden. The more elevated that the fungal burden is, the higher the probability that the diagnosis is pneumonia. The purposes of the present study were to evaluate the CT values to differentiate colonization and pneumonia in a population of immunocompromised patients overall and patients stratified on the basis of their HIV infection status. Testing of bronchoalveolar lavage (BAL) fluid samples from the whole population of qPCR-positive patients showed a mean CT value for patients with PCP of 28 (95% confidence interval [CI], 26 to 30) and a mean CT value for colonized patients of 35 (95% CI, 34 to 36) (P < 10(-3)). For the subgroup of HIV-positive patients, we demonstrated that a CT value below 27 excluded colonization and a CT value above 30 excluded PCP with a specificity of 100% and a sensitivity of 80%, respectively. In the subgroup of HIV-negative patients, we demonstrated that a CT value below 31 excluded colonization and a CT value above 35 excluded PCP with a specificity of 80% and a sensitivity of 80%, respectively. Thus, qPCR of BAL fluid samples is an important tool for the differentiation of colonization and pneumonia in P. jirovecii-infected immunocompromised patients and patients stratified on the basis of HIV infection status with different CT values. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. SU-E-J-141: Comparison of Dose Calculation On Automatically Generated MRBased ED Maps and Corresponding Patient CT for Clinical Prostate EBRT Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schadewaldt, N; Schulz, H; Helle, M

    2014-06-01

    Purpose: To analyze the effect of computing radiation dose on automatically generated MR-based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast-field dual-echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out-of-phase (echo 1) and in-phase images (echo 2) allowed for water andmore » fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re-computed on the simCT in pinnacle{sup 3}. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.« less

  9. Colorectal Cancer: Cost-effectiveness of Colonoscopy versus CT Colonography Screening with Participation Rates and Costs.

    PubMed

    van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; Goede, S Lucas; Kuipers, Ernst J; Dekker, Evelien; Stoker, Jaap; van Ballegooijen, Marjolein

    2018-06-01

    Purpose To compare the cost-effectiveness of computed tomographic (CT) colonography and colonoscopy screening by using data on unit costs and participation rates from a randomized controlled screening trial in a dedicated screening setting. Materials and Methods Observed participation rates and screening costs from the Colonoscopy or Colonography for Screening, or COCOS, trial were used in a microsimulation model to estimate costs and quality-adjusted life-years (QALYs) gained with colonoscopy and CT colonography screening. For both tests, the authors determined optimal age range and screening interval combinations assuming a 100% participation rate. Assuming observed participation for these combinations, the cost-effectiveness of both tests was compared. Extracolonic findings were not included because long-term follow-up data are lacking. Results The participation rates for colonoscopy and CT colonography were 21.5% (1276 of 5924 invitees) and 33.6% (982 of 2920 invitees), respectively. Colonoscopy was more cost-effective in the screening strategies with one or two lifetime screenings, whereas CT colonography was more cost-effective in strategies with more lifetime screenings. CT colonography was the preferred test for willingness-to-pay-thresholds of €3200 per QALY gained and higher, which is lower than the Dutch willingness-to-pay threshold of €20 000. With equal participation, colonoscopy was the preferred test independent of willingness-to-pay thresholds. The findings were robust for most of the sensitivity analyses, except with regard to relative screening costs and subsequent participation. Conclusion Because of the higher participation rates, CT colonography screening for colorectal cancer is more cost-effective than colonoscopy screening. The implementation of CT colonography screening requires previous satisfactory resolution to the question as to how best to deal with extracolonic findings. © RSNA, 2018 Online supplemental material is available for this article.

  10. Effect of Chorda Tympani Nerve Transection on Salt Taste Perception in Mice

    PubMed Central

    Ishiwatari, Yutaka; Theodorides, Maria L.; Bachmanov, Alexander A.

    2011-01-01

    Effects of gustatory nerve transection on salt taste have been studied extensively in rats and hamsters but have not been well explored in the mouse. We examined the effects of chorda tympani (CT) nerve transection on NaCl taste preferences and thresholds in outbred CD-1 mice using a high-throughput phenotyping method developed in our laboratory. To measure taste thresholds, mice were conditioned by oral self-administration of LiCl or NaCl and then presented with NaCl concentration series in 2-bottle preference tests. LiCl-conditioned and control NaCl-exposed mice were given bilateral transections of the CT nerve (LiCl-CTX, NaCl-CTX) or were left intact as controls (LiCl-CNT, NaCl-CNT). After recovery from surgery, mice received a concentration series of NaCl (0–300 mM) in 48-h 2-bottle tests. CT transection increased NaCl taste thresholds in LiCl-conditioned mice and eliminated avoidance of concentrated NaCl in control NaCl-exposed mice. This demonstrates that in mice, the CT nerve is important for detection and recognition of NaCl taste and is necessary for the normal avoidance of high concentrations of NaCl. The results of this experiment also show that the method of high-throughput phenotyping of salt taste thresholds is suitable for detecting changes in the taste periphery in mouse genetic studies. PMID:21743094

  11. Impact of tumor size and tracer uptake heterogeneity in (18)F-FDG PET and CT non-small cell lung cancer tumor delineation.

    PubMed

    Hatt, Mathieu; Cheze-le Rest, Catherine; van Baardwijk, Angela; Lambin, Philippe; Pradier, Olivier; Visvikis, Dimitris

    2011-11-01

    The objectives of this study were to investigate the relationship between CT- and (18)F-FDG PET-based tumor volumes in non-small cell lung cancer (NSCLC) and the impact of tumor size and uptake heterogeneity on various approaches to delineating uptake on PET images. Twenty-five NSCLC cancer patients with (18)F-FDG PET/CT were considered. Seventeen underwent surgical resection of their tumor, and the maximum diameter was measured. Two observers manually delineated the tumors on the CT images and the tumor uptake on the corresponding PET images, using a fixed threshold at 50% of the maximum (T(50)), an adaptive threshold methodology, and the fuzzy locally adaptive Bayesian (FLAB) algorithm. Maximum diameters of the delineated volumes were compared with the histopathology reference when available. The volumes of the tumors were compared, and correlations between the anatomic volume and PET uptake heterogeneity and the differences between delineations were investigated. All maximum diameters measured on PET and CT images significantly correlated with the histopathology reference (r > 0.89, P < 0.0001). Significant differences were observed among the approaches: CT delineation resulted in large overestimation (+32% ± 37%), whereas all delineations on PET images resulted in underestimation (from -15% ± 17% for T(50) to -4% ± 8% for FLAB) except manual delineation (+8% ± 17%). Overall, CT volumes were significantly larger than PET volumes (55 ± 74 cm(3) for CT vs. from 18 ± 25 to 47 ± 76 cm(3) for PET). A significant correlation was found between anatomic tumor size and heterogeneity (larger lesions were more heterogeneous). Finally, the more heterogeneous the tumor uptake, the larger was the underestimation of PET volumes by threshold-based techniques. Volumes based on CT images were larger than those based on PET images. Tumor size and tracer uptake heterogeneity have an impact on threshold-based methods, which should not be used for the delineation of cases of large heterogeneous NSCLC, as these methods tend to largely underestimate the spatial extent of the functional tumor in such cases. For an accurate delineation of PET volumes in NSCLC, advanced image segmentation algorithms able to deal with tracer uptake heterogeneity should be preferred.

  12. Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT.

    PubMed

    Pan, Tinsu

    2005-02-01

    We proposed a data sufficiency condition (DSC) for four-dimensional-CT (4D-CT) imaging on a multislice CT scanner, designed a pitch factor for a helical 4D-CT, and compared the acquisition time, slice sensitivity profile (SSP), effective dose, ability to cope with an irregular breathing cycle, and gating technique (retrospective or prospective) of the helical 4D-CT and the cine 4D-CT on the General Electric (GE) LightSpeed RT (4-slice), Plus (4-slice), Ultra (8-slice) and 16 (16-slice) multislice CT scanners. To satisfy the DSC, a helical or cine 4D-CT acquisition has to collect data at each location for the duration of a breathing cycle plus the duration of data acquisition for an image reconstruction. The conditions for the comparison were 20 cm coverage in the cranial-caudal direction, a 4 s breathing cycle, and half-scan reconstruction. We found that the helical 4D-CT has the advantage of a shorter scan time that is 10% shorter than that of the cine 4D-CT, and the disadvantages of 1.8 times broadening of SSP and requires an additional breathing cycle of scanning to ensure an adequate sampling at the start and end locations. The cine 4D-CT has the advantages of maintaining the same SSP as slice collimation (e.g., 8 x 2.5 mm slice collimation generates 2.5 mm SSP in the cine 4D-CT as opposed to 4.5 mm in the helical 4D-CT) and a lower dose by 4% on the 8- and 16-slice systems, and 8% on the 4-slice system. The advantage of faster scanning in the helical 4D-CT will diminish if a repeat scan at the location of a breathing irregularity becomes necessary. The cine 4D-CT performs better than the helical 4D-CT in the repeat scan because it can scan faster and is more dose efficient.

  13. 3D GGO candidate extraction in lung CT images using multilevel thresholding on supervoxels

    NASA Astrophysics Data System (ADS)

    Huang, Shan; Liu, Xiabi; Han, Guanghui; Zhao, Xinming; Zhao, Yanfeng; Zhou, Chunwu

    2018-02-01

    The earlier detection of ground glass opacity (GGO) is of great importance since GGOs are more likely to be malignant than solid nodules. However, the detection of GGO is a difficult task in lung cancer screening. This paper proposes a novel GGO candidate extraction method, which performs multilevel thresholding on supervoxels in 3D lung CT images. Firstly, we segment the lung parenchyma based on Otsu algorithm. Secondly, the voxels which are adjacent in 3D discrete space and sharing similar grayscale are clustered into supervoxels. This procedure is used to enhance GGOs and reduce computational complexity. Thirdly, Hessian matrix is used to emphasize focal GGO candidates. Lastly, an improved adaptive multilevel thresholding method is applied on segmented clusters to extract GGO candidates. The proposed method was evaluated on a set of 19 lung CT scans containing 166 GGO lesions from the Lung CT Imaging Signs (LISS) database. The experimental results show that our proposed GGO candidate extraction method is effective, with a sensitivity of 100% and 26.3 of false positives per scan (665 GGO candidates, 499 non-GGO regions and 166 GGO regions). It can handle both focal GGOs and diffuse GGOs.

  14. A Quantitative Approach to Distinguish Pneumonia From Atelectasis Using Computed Tomography Attenuation.

    PubMed

    Edwards, Rachael M; Godwin, J David; Hippe, Dan S; Kicska, Gregory

    2016-01-01

    It is known that atelectasis demonstrates greater contrast enhancement than pneumonia on computed tomography (CT). However, the effectiveness of using a Hounsfield unit (HU) threshold to distinguish pneumonia from atelectasis has never been shown. The objective of the study is to demonstrate that an HU threshold can be quantitatively used to effectively distinguish pneumonia from atelectasis. Retrospectively identified CT pulmonary angiogram examinations that did not show pulmonary embolism but contained nonaerated lungs were classified as atelectasis or pneumonia based on established clinical criteria. The HU attenuation was measured in these nonaerated lungs. Receiver operating characteristic (ROC) analysis was performed to determine the area under the ROC curve, sensitivity, and specificity of using the attenuation to distinguish pneumonia from atelectasis. Sixty-eight nonaerated lungs were measured in 55 patients. The mean (SD) enhancement was 62 (18) HU in pneumonia and 119 (24) HU in atelectasis (P < 0.001). A threshold of 92 HU diagnosed pneumonia with 97% sensitivity (confidence interval [CI], 80%-99%) and 85% specificity (CI, 70-93). Accuracy, measured as area under the ROC curve, was 0.97 (CI, 0.89-0.99). We have established that a threshold HU value can be used to confidently distinguish pneumonia from atelectasis with our standard CT pulmonary angiogram imaging protocol and patient population. This suggests that a similar threshold HU value may be determined for other scanning protocols, and application of this threshold may facilitate a more confident diagnosis of pneumonia and thus speed treatment.

  15. Cutaneous lesions in pet rabbits following subcutaneous administration of a novel bivalent vaccine against myxomatosis and rabbit haemorrhagic disease.

    PubMed

    Selleri, Paolo; Di Girolamo, Nicola; Vögtlin, Andrea; Fileccia, Ivan; Hoop, Richard; Bongiovanni, Laura

    2014-12-01

    A novel bivalent vaccine to protect against myxomatosis and rabbit haemorrhagic disease is commercially available for pet rabbits. To describe the appearance of cutaneous lesions arising in pet rabbits positive for myxoma virus (MV) by RT-PCR evaluation shortly after vaccination. Four pet rabbits presenting with papular, crusting skin lesions ~10 days after vaccination. Histological evaluation of formalin-fixed skin biopsies obtained from lesional skin (case 1). Real-time polymerase chain reaction (RT-PCR) evaluation of paraffin-embedded tissue from skin biopsies (case 1) and crusts obtained from the lesion surface (cases 2-4) for myxoma virus are reported as cycle threshold (Ct ) values. Lesions affecting the ear pinna, dorsal aspect of the nose, vulva and/or conjunctiva are reported. Histopathological findings included severe ulcerative, necrotizing dermatitis and intralesional cytoplasmic inclusion bodies in myxoma cells. DNA was amplified from all the paraffin-embedded skin biopsies (Ct  = 34-35) and crusts (Ct  = 20-24). Although a wild virus challenge cannot be definitively excluded, veterinarians and pet-owners should be aware that cutaneous lesions have been observed after vaccination with this novel vaccine in low numbers of rabbits. © 2014 ESVD and ACVD.

  16. Small median tumor diameter at cure threshold (<20 mm) among aggressive non-small cell lung cancers in male smokers predicts both chest X-ray and CT screening outcomes in a novel simulation framework.

    PubMed

    Goldwasser, Deborah L; Kimmel, Marek

    2013-01-01

    The effectiveness of population-wide lung cancer screening strategies depends on the underlying natural course of lung cancer. We evaluate the expected stage distribution in the Mayo CT screening study under an existing simulation model of non-small cell lung cancer (NSCLC) progression calibrated to the Mayo lung project (MLP). Within a likelihood framework, we evaluate whether the probability of 5-year NSCLC survival conditional on tumor diameter at detection depends significantly on screening detection modality, namely chest X-ray and computed tomography. We describe a novel simulation framework in which tumor progression depends on cellular proliferation and mutation within a stem cell compartment of the tumor. We fit this model to randomized trial data from the MLP and produce estimates of the median radiologic size at the cure threshold. We examine the goodness of model fit with respect to radiologic tumor size and 5-year NSCLC survival among incident cancers in both the MLP and Mayo CT studies. An existing model of NSCLC progression under-predicts the number of advanced-stage incident NSCLCs among males in the Mayo CT study (p-value = 0.004). The probability of 5-year NSCLC survival conditional on tumor diameter depends significantly on detection modality (p-value = 0.0312). In our new model, selected solution sets having a median tumor diameter of 16.2-22.1 mm at cure threshold among aggressive NSCLCs predict both MLP and Mayo CT outcomes. We conclude that the median lung tumor diameter at cure threshold among aggressive NSCLCs in male smokers may be small (<20 mm). Copyright © 2012 UICC.

  17. Improved aortic enhancement in CT angiography using slope-based triggering with table speed optimization: a pilot study.

    PubMed

    Bashir, Mustafa R; Weber, Paul W; Husarik, Daniela B; Howle, Laurens E; Nelson, Rendon C

    2012-08-01

    To assess whether a scan triggering technique based on the slope of the time-attenuation curve combined with table speed optimization may improve arterial enhancement in aortic CT angiography compared to conventional threshold-based triggering techniques. Measurements of arterial enhancement were performed in a physiologic flow phantom over a range of simulated cardiac outputs (2.2-8.1 L/min) using contrast media boluses of 80 and 150 mL injected at 4 mL/s. These measurements were used to construct computer models of aortic attenuation in CT angiography, using cardiac output, aortic diameter, and CT table speed as input parameters. In-plane enhancement was calculated for normal and aneurysmal aortic diameters. Calculated arterial enhancement was poor (<150 HU) along most of the scan length using the threshold-based triggering technique for low cardiac outputs and the aneurysmal aorta model. Implementation of the slope-based triggering technique with table speed optimization improved enhancement in all scenarios and yielded good- (>200 HU; 13/16 scenarios) to excellent-quality (>300 HU; 3/16 scenarios) enhancement in all cases. Slope-based triggering with table speed optimization may improve the technical quality of aortic CT angiography over conventional threshold-based techniques, and may reduce technical failures related to low cardiac output and slow flow through an aneurysmal aorta.

  18. SU-E-J-219: A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maspero, M.; Meijer, G.J.; Lagendijk, J.J.W.

    2015-06-15

    Purpose: To develop an image processing method for MRI-based generation of electron density maps, known as pseudo-CT (pCT), without usage of model- or atlas-based segmentation, and to evaluate the method in the pelvic and head-neck region against CT. Methods: CT and MRI scans were obtained from the pelvic region of four patients in supine position using a flat table top only for CT. Stratified CT maps were generated by classifying each voxel based on HU ranges into one of four classes: air, adipose tissue, soft tissue or bone.A hierarchical region-selective algorithm, based on automatic thresholding and clustering, was used tomore » classify tissues from MR Dixon reconstructed fat, In-Phase (IP) and Opposed-Phase (OP) images. First, a body mask was obtained by thresholding the IP image. Subsequently, an automatic threshold on the Dixon fat image differentiated soft and adipose tissue. K-means clustering on IP and OP images resulted in a mask that, via a connected neighborhood analysis, allowing the user to select the components corresponding to bone structures.The pCT was estimated through assignment of bulk HU to the tissue classes. Bone-only Digital Reconstructed Radiographs (DRR) were generated as well. The pCT images were rigidly registered to the stratified CT to allow a volumetric and voxelwise comparison. Moreover, pCTs were also calculated within the head-neck region in two volunteers using the same pipeline. Results: The volumetric comparison resulted in differences <1% for each tissue class. A voxelwise comparison showed a good classification, ranging from 64% to 98%. The primary misclassified classes were adipose/soft tissue and bone/soft tissue. As the patients have been imaged on different table tops, part of the misclassification error can be explained by misregistration. Conclusion: The proposed approach does not rely on an anatomy model providing the flexibility to successfully generate the pCT in two different body sites. This research is founded by ZonMw IMDI Programme, project name: “RASOR sharp: MRI based radiotherapy planning using a single MRI sequence”, project number: 10-104003010.« less

  19. Comparison of five segmentation tools for 18F-fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer.

    PubMed

    Schinagl, Dominic A X; Vogel, Wouter V; Hoffmann, Aswin L; van Dalen, Jorn A; Oyen, Wim J; Kaanders, Johannes H A M

    2007-11-15

    Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with (18)F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition.

  20. Coronary artery calcium: a multi-institutional, multimanufacturer international standard for quantification at cardiac CT.

    PubMed

    McCollough, Cynthia H; Ulzheimer, Stefan; Halliburton, Sandra S; Shanneik, Kaiss; White, Richard D; Kalender, Willi A

    2007-05-01

    To develop a consensus standard for quantification of coronary artery calcium (CAC). A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.

  1. Application of machine learning methodology for pet-based definition of lung cancer

    PubMed Central

    Kerhet, A.; Small, C.; Quon, H.; Riauka, T.; Schrader, L.; Greiner, R.; Yee, D.; McEwan, A.; Roa, W.

    2010-01-01

    We applied a learning methodology framework to assist in the threshold-based segmentation of non-small-cell lung cancer (nsclc) tumours in positron-emission tomography–computed tomography (pet–ct) imaging for use in radiotherapy planning. Gated and standard free-breathing studies of two patients were independently analysed (four studies in total). Each study had a pet–ct and a treatment-planning ct image. The reference gross tumour volume (gtv) was identified by two experienced radiation oncologists who also determined reference standardized uptake value (suv) thresholds that most closely approximated the gtv contour on each slice. A set of uptake distribution-related attributes was calculated for each pet slice. A machine learning algorithm was trained on a subset of the pet slices to cope with slice-to-slice variation in the optimal suv threshold: that is, to predict the most appropriate suv threshold from the calculated attributes for each slice. The algorithm’s performance was evaluated using the remainder of the pet slices. A high degree of geometric similarity was achieved between the areas outlined by the predicted and the reference suv thresholds (Jaccard index exceeding 0.82). No significant difference was found between the gated and the free-breathing results in the same patient. In this preliminary work, we demonstrated the potential applicability of a machine learning methodology as an auxiliary tool for radiation treatment planning in nsclc. PMID:20179802

  2. Relationship Between ABCB1 Polymorphisms and Cold Pain Sensitivity Among Healthy Opioid-naive Malay Males.

    PubMed

    Zahari, Zalina; Lee, Chee Siong; Ibrahim, Muslih Abdulkarim; Musa, Nurfadhlina; Mohd Yasin, Mohd Azhar; Lee, Yeong Yeh; Tan, Soo Choon; Mohamad, Nasir; Ismail, Rusli

    2017-09-01

    Endogenous and exogenous opioids are substrates of the permeability glycoprotein (P-gp) efflux transporter, which is encoded by the ABCB1 (MDR1) gene. Genetic polymorphisms of ABCB1 may contribute to interindividual differences in pain modulation and analgesic responses. We investigated the relationship between ABCB1 polymorphisms and cold pain sensitivity among healthy males. Cold pain responses, including pain threshold and pain tolerance, were measured using the cold-pressor test (CPT). DNA was extracted from whole blood and genotyped for ABCB1 polymorphisms, including c.1236C>T (rs1128503), c.2677G>T/A (rs2032582), and c.3435C>T (rs1045642), using the allelic discrimination real-time polymerase chain reaction. A total of 152 participants were recruited in this observational study. Frequencies of mutated allele for c.1236C>T, c.2677G>T/A, and c.3435C>T polymorphisms were 56.6%, 49.7%, and 43.4%, respectively. Our results revealed an association of the CGC/CGC diplotype (c.1236C>T, c.2677G>T/A, and c.3435C>T) with cold pain sensitivity. Participants with the CGC/CGC diplotype had 90% and 72% higher cold pain thresholds (87.62 seconds vs. 46.19 seconds, P = 0.010) and cold pain tolerances (97.24 seconds vs. 56.54 seconds, P = 0.021), respectively, when compared with those without the diplotype. The CGC/CGC diplotype of ABCB1 polymorphisms was associated with variability in cold pain threshold and pain tolerance in healthy males. © 2016 World Institute of Pain.

  3. [Development of Audio Indicator System for Respiratory Dynamic CT Imaging].

    PubMed

    Muramatsu, Shun; Moriya, Hiroshi; Tsukagoshi, Shinsuke; Yamada, Norikazu

    We created the device, which can conduct a radiological technologist's voice to a subject during CT scanning. For 149 lung cancer, dynamic respiratory CT were performed. 92 cases were performed using this device, the others were without this device. The respiratory cycle and respiratory amplitude were analyzed from the lung density. A stable respirating cycle was obtained by using the audio indicator system. The audio indicator system is useful for respiratory dynamic CT.

  4. Dynamic-thresholding level set: a novel computer-aided volumetry method for liver tumors in hepatic CT images

    NASA Astrophysics Data System (ADS)

    Cai, Wenli; Yoshida, Hiroyuki; Harris, Gordon J.

    2007-03-01

    Measurement of the volume of focal liver tumors, called liver tumor volumetry, is indispensable for assessing the growth of tumors and for monitoring the response of tumors to oncology treatments. Traditional edge models, such as the maximum gradient and zero-crossing methods, often fail to detect the accurate boundary of a fuzzy object such as a liver tumor. As a result, the computerized volumetry based on these edge models tends to differ from manual segmentation results performed by physicians. In this study, we developed a novel computerized volumetry method for fuzzy objects, called dynamic-thresholding level set (DT level set). An optimal threshold value computed from a histogram tends to shift, relative to the theoretical threshold value obtained from a normal distribution model, toward a smaller region in the histogram. We thus designed a mobile shell structure, called a propagating shell, which is a thick region encompassing the level set front. The optimal threshold calculated from the histogram of the shell drives the level set front toward the boundary of a liver tumor. When the volume ratio between the object and the background in the shell approaches one, the optimal threshold value best fits the theoretical threshold value and the shell stops propagating. Application of the DT level set to 26 hepatic CT cases with 63 biopsy-confirmed hepatocellular carcinomas (HCCs) and metastases showed that the computer measured volumes were highly correlated with those of tumors measured manually by physicians. Our preliminary results showed that DT level set was effective and accurate in estimating the volumes of liver tumors detected in hepatic CT images.

  5. Effect of ionizing radiation on the quantitative detection of Salmonella using real-time PCR

    NASA Astrophysics Data System (ADS)

    Lim, Sangyong; Jung, Jinwoo; Kim, Minjeong; Ryu, Sangryeol; Kim, Dongho

    2008-09-01

    Food irradiation is an economically viable technology for inactivating foodborne pathogens, but irradiation can mask pathogens in unhygienically prepared food. The aim of this study was to investigate the effect of irradiation treatment on the detection of Salmonella using real-time PCR. Three commercially available kits were tested, of which the InstaGene Matrix procedure was most effective in preparing template DNA from Salmonella exposed to radiation in broth culture. The minimum level of detection by real-time PCR combined with InstaGene Matrix was 3 log units of Salmonella per milliliter. However, when pure cultures of Salmonella were irradiated at 3 and 5 kGy, the cycle threshold ( CT) increased 1-1.5-fold compared to irradiation at 0 and 1 kGy. This indicated that irradiation treatment may result in an underestimation of bacterial counts due to radiation-induced DNA lesions. We also compared CT values in inoculated chicken homogenates before and after irradiation, which in this model caused a 1.3-3.3-fold underestimation of bacterial counts with respect to irradiation dose.

  6. Multicenter evaluation of molecular and culture-dependent diagnostics for Shigella species and Entero-invasive Escherichia coli in the Netherlands.

    PubMed

    van den Beld, Maaike J C; Friedrich, Alexander W; van Zanten, Evert; Reubsaet, Frans A G; Kooistra-Smid, Mirjam A M D; Rossen, John W A

    2016-12-01

    An inter-laboratory collaborative trial for the evaluation of diagnostics for detection and identification of Shigella species and Entero-invasive Escherichia coli (EIEC) was performed. Sixteen Medical Microbiological Laboratories (MMLs) participated. MMLs were interviewed about their diagnostic methods and a sample panel, consisting of DNA-extracts and spiked stool samples with different concentrations of Shigella flexneri, was provided to each MML. The results of the trial showed an enormous variety in culture-dependent and molecular diagnostic techniques currently used among MMLs. Despite the various molecular procedures, 15 out of 16 MMLs were able to detect Shigella species or EIEC in all the samples provided, showing that the diversity of methods has no effect on the qualitative detection of Shigella flexneri. In contrast to semi quantitative analysis, the minimum and maximum values per sample differed by approximately five threshold cycles (Ct-value) between the MMLs included in the study. This indicates that defining a uniform Ct-value cut-off for notification to health authorities is not advisable. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Effect of androgen deprivation therapy on intraprostatic tumour volume identified on 18F choline PET/CT for prostate dose painting radiotherapy.

    PubMed

    Chan, Joachim; Carver, Antony; Brunt, John N H; Vinjamuri, Sobhan; Syndikus, Isabel

    2017-03-01

    Prostate dose painting radiotherapy requires the accurate identification of dominant intraprostatic lesions (DILs) to be used as boost volumes; these can be identified on multiparametric MRI (mpMRI) or choline positron emission tomography (PET)/CT. Planning scans are usually performed after 2-3 months of androgen deprivation therapy (ADT). We examine the effect of ADT on choline tracer uptake and boost volumes identified on choline PET/CT. Fluoroethylcholine ( 18 F choline) PET/CT was performed for dose painting radiotherapy planning in patients with intermediate- to high-risk prostate cancer. Initially, they were performed at planning. Owing to low visual tracer uptake, PET/CT for subsequent patients was performed at staging. We compared these two approaches on intraprostatic lesions obtained on PET using both visual and automatic threshold methods [prostate maximum standardized uptake value (SUV max ) 60%] when compared with mpMRI. PET/CT was performed during ADT in 11 patients (median duration of 85 days) and before ADT in 29 patients. ADT significantly reduced overall prostate volume by 17%. During ADT, prostate SUV max was lower although it did not reach statistical significance (4.2 vs 6.6, p = 0.06); three patients had no visually identifiable PET DIL; and visually defined PET DILs were significantly smaller than corresponding mpMRI DILs (p = 0.03). However, all patients scanned before ADT had at least one visually identifiable PET DIL, with no significant size difference between MRI and visually defined PET DILs. In both groups, threshold PET produced larger DILs than visual PET. Both PET methods have moderate sensitivity (0.50-0.68) and high specificity (0.85-0.98) for identifying MRI-defined disease. For visual contouring of boost volumes in prostate dose painting radiotherapy, 18 F choline PET/CT should be performed before ADT. For threshold contouring of boost volumes using our PET/CT scanning protocol, threshold levels of above 60% prostate SUV max may be more suitable. Additional use of PET with MRI for radiotherapy planning can significantly change the overall boost volumes compared with using MRI alone. Advances in knowledge: For prostate dose painting radiotherapy, the additional use of 18 F choline PET with MRI can significantly change the overall boost volumes, and PET should be performed before hormone therapy, especially if boost volumes are visually identified.

  8. Dietary Influences on Alpha-Methylacyl-CoA Racemase (AMACR) Expression in the Prostate

    DTIC Science & Technology

    2008-04-01

    calculated from the point where each curve crossed the threshold line (Ct) using the following equation : Rel. value = 2[Ct(control) Ct(test)]test...pancreatic cancer. J Hum Genet 2005;50:159–67. 41. Armes JE, Hammet F, de Silva M, et al. Candidate tumor-suppressor genes on chromosome arm 8p in early

  9. Variation in the Hearing Threshold in Women during the Menstrual Cycle

    PubMed Central

    Souza, Dayse da Silva; Luckwu, Brunna; Andrade, Wagner Teobaldo Lopes de; Pessoa, Luciane Spinelli de Figueiredo; Nascimento, João Agnaldo do; Rosa, Marine Raquel Diniz da

    2017-01-01

    Introduction  The hormonal changes that occur during the menstrual cycle and their relationship with hearing problems have been studied. However, they have not been well explained. Objective  The objective of our study is to investigate the variation in hearing thresholds in women during the menstrual cycle. Method  We conducted a cohort and longitudinal study. It was composed of 30 volunteers, aged 18–39 years old, of which 20 were women during the phases of the menstrual cycle and 10 were men (control group) who underwent audiometry and impedance exams, to correlate the possible audiological changes in each phase of the menstrual cycle. Results  There were significant changes in hearing thresholds observed during the menstrual cycle phases in the group of women who used hormonal contraceptives and the group who did not use such contraceptives. Improved hearing thresholds were observed in the late follicular phase in the group who did not use hormonal contraceptives and the hearing thresholds at high frequencies were better. Throughout the menstrual cycle phases, the mean variation was 3.6 db HL between weeks in the group who used hormonal contraceptives and 4.09 db HL in the group who did not use them. Conclusions  The present study found that there may be a relationship between hearing changes and hormonal fluctuations during the menstrual cycle based on changes in the hearing thresholds of women. In addition, this study suggests that estrogen has an otoprotective effect on hearing, since the best hearing thresholds were found when estrogen was at its maximum peak. PMID:29018493

  10. Variation in the Hearing Threshold in Women during the Menstrual Cycle.

    PubMed

    Souza, Dayse da Silva; Luckwu, Brunna; Andrade, Wagner Teobaldo Lopes de; Pessoa, Luciane Spinelli de Figueiredo; Nascimento, João Agnaldo do; Rosa, Marine Raquel Diniz da

    2017-10-01

    Introduction  The hormonal changes that occur during the menstrual cycle and their relationship with hearing problems have been studied. However, they have not been well explained. Objective  The objective of our study is to investigate the variation in hearing thresholds in women during the menstrual cycle. Method  We conducted a cohort and longitudinal study. It was composed of 30 volunteers, aged 18-39 years old, of which 20 were women during the phases of the menstrual cycle and 10 were men (control group) who underwent audiometry and impedance exams, to correlate the possible audiological changes in each phase of the menstrual cycle. Results  There were significant changes in hearing thresholds observed during the menstrual cycle phases in the group of women who used hormonal contraceptives and the group who did not use such contraceptives. Improved hearing thresholds were observed in the late follicular phase in the group who did not use hormonal contraceptives and the hearing thresholds at high frequencies were better. Throughout the menstrual cycle phases, the mean variation was 3.6 db HL between weeks in the group who used hormonal contraceptives and 4.09 db HL in the group who did not use them. Conclusions  The present study found that there may be a relationship between hearing changes and hormonal fluctuations during the menstrual cycle based on changes in the hearing thresholds of women. In addition, this study suggests that estrogen has an otoprotective effect on hearing, since the best hearing thresholds were found when estrogen was at its maximum peak.

  11. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Chan, F; Newman, B

    2014-06-15

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less

  12. Scope for energy improvement for hospital imaging services in the USA.

    PubMed

    Esmaeili, Amin; Twomey, Janet M; Overcash, Michael R; Soltani, Seyed A; McGuire, Charles; Ali, Kamran

    2015-04-01

    To aid radiologists by measuring the carbon footprint of CT scans by quantifying in-hospital and out-of-hospital energy use and to assess public health impacts. The study followed a standard life cycle assessment protocol to measure energy from a CT scan then expanding to all hospital electrical energy related to CT usage. In addition, all the fuel energy used to generate electricity and to manufacture the CT consumables was measured. The study was conducted at two hospitals. The entire life cycle energy for a CT scan was 24-34 kWh of natural resource energy per scan. The actual active patient scan energy that produces the images is only about 1.6% of this total life cycle energy. This large multiplier to get total CT energy is a previously undocumented environmental response to the direct radiology order for a patient CT scan. The CT in-hospital energy related to idle periods, where the machine is on but no patients are being scanned and is 14-30-fold higher than the energy used for the CT image. The in-hospital electrical energy of a CT scan makes up only about 25% of the total energy footprint. The rest is generated outside the hospital: 54-62% for generation and transmission of the electricity, while 13-22% is for all the energy to make the consumables. Different CT scanners have some influences on the results and could help guide purchase of CT equipment. The transparent, detailed life cycle approach allows the data from this study to be used by radiologists to examine details of both direct and of unseen energy impacts of CT scans. The public health (outside-the-hospital) impact (including the patients receiving a CT) needs to be measured and included. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. Is basal ultrasensitive measurement of calcitonin capable of substituting for the pentagastrin-stimulation test?

    PubMed

    Pina, Géraldine; Dubois, Séverine; Murat, Arnaud; Berger, Nicole; Niccoli, Patricia; Peix, Jean-Louis; Cohen, Régis; Guillausseau, Claudine; Charrie, Anne; Chabre, Olivier; Cornu, Catherine; Borson-Chazot, Françoise; Rohmer, Vincent

    2013-03-01

    To evaluate a second-generation assay for basal serum calcitonin (CT) measurements compared with the pentagastrin-stimulation test for the diagnosis of inherited medullary thyroid carcinoma (MTC) and the follow-up of patients with MTC after surgery. Recent American Thyroid Association recommendations suggest the use of basal CT alone to diagnose and assess follow-up of MTC as the pentagastrin (Pg) test is unavailable in many countries. Multicentric prospective study. A total of 162 patients with basal CT <10 ng/l were included: 54 asymptomatic patients harboured noncysteine 'rearranged during transfection' (RET) proto-oncogene mutations and 108 patients had entered follow-up of MTC after surgery. All patients underwent basal and Pg-stimulated CT measurements using a second-generation assay with 5-ng/l functional sensitivity. Ninety-five per cent of patients with basal CT ≥ 5 ng/l and 25% of patients with basal CT <5 ng/l had a positive Pg-stimulation test (Pg CT >10 ng/l). Compared with the reference Pg test, basal CT ≥ 5 ng/l had 99% specificity, a 95%-positive predictive value but only 35% sensitivity (P < 0.0001). Overall, there were 31% less false-negative results using a 5-ng/l threshold for basal CT instead of the previously used 10-ng/l threshold. The ultrasensitive CT assay reduces the false-negative rate of basal CT measurements when diagnosing familial MTC and in postoperative follow-up compared with previously used assays. However, its sensitivity to detect C-cell disease remains lower than that of the Pg-stimulation test. © 2012 Blackwell Publishing Ltd.

  14. A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay.

    PubMed

    Blakemore, Robert; Nabeta, Pamela; Davidow, Amy L; Vadwai, Viral; Tahirli, Rasim; Munsamy, Vanisha; Nicol, Mark; Jones, Martin; Persing, David H; Hillemann, Doris; Ruesch-Gerdes, Sabine; Leisegang, Felicity; Zamudio, Carlos; Rodrigues, Camilla; Boehme, Catharina C; Perkins, Mark D; Alland, David

    2011-11-01

    The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterial burden is an important biomarker for disease severity, infection control risk, and response to therapy. Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. Xpert MTB/RIF results were compared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r(s) = -0.77) and directly from sputum (r(s) =-0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r(s) = 0.68) and semiquantitative colony counts (r(s) = -0.56) was weaker than smear. Tests of paired same-patient sputum showed that high viscosity sputum samples contained ×32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier in microscopy. Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.

  15. Effects of High-Intensity Interval Training versus Continuous Training on Physical Fitness, Cardiovascular Function and Quality of Life in Heart Failure Patients.

    PubMed

    Benda, Nathalie M M; Seeger, Joost P H; Stevens, Guus G C F; Hijmans-Kersten, Bregina T P; van Dijk, Arie P J; Bellersen, Louise; Lamfers, Evert J P; Hopman, Maria T E; Thijssen, Dick H J

    2015-01-01

    Physical fitness is an important prognostic factor in heart failure (HF). To improve fitness, different types of exercise have been explored, with recent focus on high-intensity interval training (HIT). We comprehensively compared effects of HIT versus continuous training (CT) in HF patients NYHA II-III on physical fitness, cardiovascular function and structure, and quality of life, and hypothesize that HIT leads to superior improvements compared to CT. Twenty HF patients (male:female 19:1, 64±8 yrs, ejection fraction 38±6%) were allocated to 12-weeks of HIT (10*1-minute at 90% maximal workload-alternated by 2.5 minutes at 30% maximal workload) or CT (30 minutes at 60-75% of maximal workload). Before and after intervention, we examined physical fitness (incremental cycling test), cardiac function and structure (echocardiography), vascular function and structure (ultrasound) and quality of life (SF-36, Minnesota living with HF questionnaire (MLHFQ)). Training improved maximal workload, peak oxygen uptake (VO2peak) related to the predicted VO2peak, oxygen uptake at the anaerobic threshold, and maximal oxygen pulse (all P<0.05), whilst no differences were present between HIT and CT (N.S.). We found no major changes in resting cardiovascular function and structure. SF-36 physical function score improved after training (P<0.05), whilst SF-36 total score and MLHFQ did not change after training (N.S.). Training induced significant improvements in parameters of physical fitness, although no evidence for superiority of HIT over CT was demonstrated. No major effect of training was found on cardiovascular structure and function or quality of life in HF patients NYHA II-III. Nederlands Trial Register NTR3671.

  16. Quantification of pulmonary vessel diameter in low-dose CT images

    NASA Astrophysics Data System (ADS)

    Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate

    2015-03-01

    Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.

  17. TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podgorsak, A; Bednarek, D; Rudin, S

    2016-06-15

    Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence.more » The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.« less

  18. Spontaneous Subarachnoid Hemorrhage: A Systematic Review and Meta-Analysis Describing the Diagnostic Accuracy of History, Physical Exam, Imaging, and Lumbar Puncture with an Exploration of Test Thresholds

    PubMed Central

    Carpenter, Christopher R.; Hussain, Adnan M.; Ward, Michael J.; Zipfel, Gregory J.; Fowler, Susan; Pines, Jesse M.; Sivilotti, Marco L.A.

    2016-01-01

    Background Spontaneous subarachnoid hemorrhage (SAH) is a rare, but serious etiology of headache. The diagnosis of SAH is especially challenging in alert, neurologically intact patients, as missed or delayed diagnosis can be catastrophic. Objectives To perform a diagnostic accuracy systematic review and meta-analysis of history, physical examination, cerebrospinal fluid (CSF) tests, computed tomography (CT), and clinical decision rules for spontaneous SAH. A secondary objective was to delineate probability of disease thresholds for imaging and lumbar puncture (LP). Methods PUBMED, EMBASE, SCOPUS, and research meeting abstracts were searched up to June 2015 for studies of emergency department (ED) patients with acute headache clinically concerning for spontaneous SAH. QUADAS-2 was used to assess study quality and, when appropriate, meta-analysis was conducted using random effects models. Outcomes were sensitivity, specificity, positive (LR+) and negative (LR−) likelihood ratios. To identify test- and treatment-thresholds, we employed the Pauker-Kassirer method with Bernstein test-indication curves using the summary estimates of diagnostic accuracy. Results A total of 5,022 publications were identified, of which 122 underwent full text-review; 22 studies were included (average SAH prevalence 7.5%). Diagnostic studies differed in assessment of history and physical exam findings, CT technology, analytical techniques used to identify xanthochromia, and criterion standards for SAH. Study quality by QUADAS-2 was variable; however, most had a relatively low-risk of biases. A history of neck pain (LR+ 4.1 [95% CI 2.2-7.6]) and neck stiffness on physical exam (LR+ 6.6 [4.0-11.0]) were the individual findings most strongly associated with SAH. Combinations of findings may rule out SAH, yet promising clinical decision rules await external validation. Non-contrast cranial CT within 6 hours of headache onset accurately ruled-in (LR+ 230 [6-8700]) and ruled-out SAH (LR− 0.01 [0-0.04]); CT beyond 6 hours had a LR− of 0.07 [0.01-0.61]. CSF analyses had lower diagnostic accuracy, whether using red blood cell (RBC) count or xanthochromia. At a threshold RBC count of 1,000 × 106/L, the LR+ was 5.7 [1.4-23] and LR− 0.21 [0.03-1.7]. Using the pooled estimates of diagnostic accuracy and testing risks and benefits, we estimate LP only benefits CT negative patients when the pre-LP probability of SAH is on the order of 5%, which corresponds to a pre-CT probability greater than 20%. Conclusions Less than one in ten headache patients concerning for SAH are ultimately diagnosed with SAH in recent studies. While certain symptoms and signs increase or decrease the likelihood of SAH, no single characteristic is sufficient to rule-in or rule-out SAH. Within 6 hours of symptom onset, non-contrast cranial CT is highly accurate, while a negative CT beyond 6 hours substantially reduces the likelihood of SAH. LP appears to benefit relatively few patients within a narrow pre-test probability range. With improvements in CT technology and an expanding body of evidence, test-thresholds for LP may become more precise, obviating the need for a post-CT LP in more acute headache patients. Existing SAH clinical decision rules await external validation, but offer the potential to identify subsets most likely to benefit from post-CT LP, angiography, or no further testing. PMID:27306497

  19. A 2D threshold of the condylar-C1 interval to maximize identification of patients at high risk for atlantooccipital dislocation using computed tomography.

    PubMed

    Ravindra, Vijay M; Riva-Cambrin, Jay; Horn, Kevin P; Ginos, Jason; Brockmeyer, Russell; Guan, Jian; Rampton, John; Brockmeyer, Douglas L

    2017-04-01

    OBJECTIVE Measurement of the occipital condyle-C1 interval (CCI) is important in the evaluation of atlantooccipital dislocation (AOD) in pediatric trauma patients. The authors studied a large cohort of children with and without AOD to identify a 2D measurement threshold that maximizes the diagnostic yield of the CCI on cervical spine CT scans obtained in trauma patients. METHODS This retrospective, single-center study included all children who underwent CT of the cervical spine at Primary Children's Hospital from January 1, 2011, through December 31, 2014, for trauma evaluation. Bilateral CCI measurements in the coronal (3 measurements per side) and sagittal (4 measurements per side) planes were recorded. Using an iterative method, the authors determined optimal cutoffs for the maximal CCI in each plane in relation to AOD. The primary outcome was AOD requiring occipitocervical fusion. RESULTS A total of 597 pediatric patients underwent cervical spine CT for trauma evaluation: 578 patients without AOD and 19 patients with AOD requiring occipitocervical fusion. The authors found a statistically significant correlation between CCI and age (p < 0.001), with younger patients having higher CCIs. Using a 2D threshold requiring a sagittal CCI ≥ 2.5 mm and a coronal CCI ≥ 3.5 mm predicted AOD with a sensitivity of 95%, a specificity of 73%, positive predictive value of 10.3%, and negative predictive value of 99%. The accuracy of this 2D threshold was 84%. CONCLUSIONS In the present study population, age-dependent differences in the CCI were found on CT scans of the cervical spine in a large cohort of patients with and without AOD. A 2D CCI threshold as a screening method maximizes identification of patients at high risk for AOD while minimizing unnecessary imaging studies in children being evaluated for trauma.

  20. Sub-Volumetric Classification and Visualization of Emphysema Using a Multi-Threshold Method and Neural Network

    NASA Astrophysics Data System (ADS)

    Tan, Kok Liang; Tanaka, Toshiyuki; Nakamura, Hidetoshi; Shirahata, Toru; Sugiura, Hiroaki

    Chronic Obstructive Pulmonary Disease is a disease in which the airways and tiny air sacs (alveoli) inside the lung are partially obstructed or destroyed. Emphysema is what occurs as more and more of the walls between air sacs get destroyed. The goal of this paper is to produce a more practical emphysema-quantification algorithm that has higher correlation with the parameters of pulmonary function tests compared to classical methods. The use of the threshold range from approximately -900 Hounsfield Unit to -990 Hounsfield Unit for extracting emphysema from CT has been reported in many papers. From our experiments, we realize that a threshold which is optimal for a particular CT data set might not be optimal for other CT data sets due to the subtle radiographic variations in the CT images. Consequently, we propose a multi-threshold method that utilizes ten thresholds between and including -900 Hounsfield Unit and -990 Hounsfield Unit for identifying the different potential emphysematous regions in the lung. Subsequently, we divide the lung into eight sub-volumes. From each sub-volume, we calculate the ratio of the voxels with the intensity below a certain threshold. The respective ratios of the voxels below the ten thresholds are employed as the features for classifying the sub-volumes into four emphysema severity classes. Neural network is used as the classifier. The neural network is trained using 80 training sub-volumes. The performance of the classifier is assessed by classifying 248 test sub-volumes of the lung obtained from 31 subjects. Actual diagnoses of the sub-volumes are hand-annotated and consensus-classified by radiologists. The four-class classification accuracy of the proposed method is 89.82%. The sub-volumetric classification results produced in this study encompass not only the information of emphysema severity but also the distribution of emphysema severity from the top to the bottom of the lung. We hypothesize that besides emphysema severity, the distribution of emphysema severity in the lung also plays an important role in the assessment of the overall functionality of the lung. We confirm our hypothesis by showing that the proposed sub-volumetric classification results correlate with the parameters of pulmonary function tests better than classical methods. We also visualize emphysema using a technique called the transparent lung model.

  1. Limited reliability of computed tomographic perfusion acute infarct volume measurements compared with diffusion-weighted imaging in anterior circulation stroke.

    PubMed

    Schaefer, Pamela W; Souza, Leticia; Kamalian, Shervin; Hirsch, Joshua A; Yoo, Albert J; Kamalian, Shahmir; Gonzalez, R Gilberto; Lev, Michael H

    2015-02-01

    Diffusion-weighted imaging (DWI) can reliably identify critically ischemic tissue shortly after stroke onset. We tested whether thresholded computed tomographic cerebral blood flow (CT-CBF) and CT-cerebral blood volume (CT-CBV) maps are sufficiently accurate to substitute for DWI for estimating the critically ischemic tissue volume. Ischemic volumes of 55 patients with acute anterior circulation stroke were assessed on DWI by visual segmentation and on CT-CBF and CT-CBV with segmentation using 15% and 30% thresholds, respectively. The contrast:noise ratios of ischemic regions on the DWI and CT perfusion (CTP) images were measured. Correlation and Bland-Altman analyses were used to assess the reliability of CTP. Mean contrast:noise ratios for DWI, CT-CBF, and CT-CBV were 4.3, 0.9, and 0.4, respectively. CTP and DWI lesion volumes were highly correlated (R(2)=0.87 for CT-CBF; R(2)=0.83 for CT-CBV; P<0.001). Bland-Altman analyses revealed little systemic bias (-2.6 mL) but high measurement variability (95% confidence interval, ±56.7 mL) between mean CT-CBF and DWI lesion volumes, and systemic bias (-26 mL) and high measurement variability (95% confidence interval, ±64.0 mL) between mean CT-CBV and DWI lesion volumes. A simulated treatment study demonstrated that using CTP-CBF instead of DWI for detecting a statistically significant effect would require at least twice as many patients. The poor contrast:noise ratios of CT-CBV and CT-CBF compared with those of DWI result in large measurement error, making it problematic to substitute CTP for DWI in selecting individual acute stroke patients for treatment. CTP could be used for treatment studies of patient groups, but the number of patients needed to identify a significant effect is much higher than the number needed if DWI is used. © 2014 American Heart Association, Inc.

  2. The Development of a Cognitive Tool for Teaching and Learning Fractions in the Mathematics Classroom: A Design-Based Study

    ERIC Educational Resources Information Center

    Kong, S. C.

    2008-01-01

    Two cycles of design-based research of a cognitive tool (CT) for teaching fractions have been completed. Following the success of a quasi-experimental study of the enhanced CT derived from the second cycle of design-based research, this article reports the findings of a pre-test-post-test control group empirical study using the enhanced CT in the…

  3. xCT expression reduces the early cell cycle requirement for calcium signaling

    PubMed Central

    Lastro, Michele; Kourtidis, Antonis; Farley, Kate; Conklin, Douglas S.

    2009-01-01

    Calcium has long been recognized as an important regulator of cell cycle transitions although the mechanisms are largely unknown. A functional genomic screen has identified genes involved in the regulation of early cell cycle progression by calcium. These genes when overexpressed confer the ability to bypass the G1/S arrest induced by Ca2+- channel antagonists in mouse fibroblasts. Overexpression of the cystine-glutamate exchanger, xCT, had the greatest ability to evade calcium antagonist-induced cell cycle arrest. xCT carries out the rate limiting step of glutathione synthesis in many cell types and is responsible for the uptake of cystine in most human cancer cell lines. Functional analysis indicates that the cystine uptake activity of xCT overcomes the G1/S arrest induced by Ca2+- channel antagonists by bypassing the requirement for calcium signaling. Since cells overexpressing xCT were found to have increased levels and activity of the AP-1 transcription factor in G1, redox stimulation of AP-1 activity accounts for the observed growth of these cells in the presence of calcium channel antagonists. These results suggest that reduced calcium signaling impairs AP-1 activation and that xCT expression may directly affect cell proliferation. PMID:18054200

  4. A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times

    NASA Astrophysics Data System (ADS)

    Edmund, Jens M.; Kjer, Hans M.; Van Leemput, Koen; Hansen, Rasmus H.; Andersen, Jon AL; Andreasen, Daniel

    2014-12-01

    Radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, so-called MRI-only RT, would remove the systematic registration error between MR and computed tomography (CT), and provide co-registered MRI for assessment of treatment response and adaptive RT. Electron densities, however, need to be assigned to the MRI images for dose calculation and patient setup based on digitally reconstructed radiographs (DRRs). Here, we investigate the geometric and dosimetric performance for a number of popular voxel-based methods to generate a so-called pseudo CT (pCT). Five patients receiving cranial irradiation, each containing a co-registered MRI and CT scan, were included. An ultra short echo time MRI sequence for bone visualization was used. Six methods were investigated for three popular types of voxel-based approaches; (1) threshold-based segmentation, (2) Bayesian segmentation and (3) statistical regression. Each approach contained two methods. Approach 1 used bulk density assignment of MRI voxels into air, soft tissue and bone based on logical masks and the transverse relaxation time T2 of the bone. Approach 2 used similar bulk density assignments with Bayesian statistics including or excluding additional spatial information. Approach 3 used a statistical regression correlating MRI voxels with their corresponding CT voxels. A similar photon and proton treatment plan was generated for a target positioned between the nasal cavity and the brainstem for all patients. The CT agreement with the pCT of each method was quantified and compared with the other methods geometrically and dosimetrically using both a number of reported metrics and introducing some novel metrics. The best geometrical agreement with CT was obtained with the statistical regression methods which performed significantly better than the threshold and Bayesian segmentation methods (excluding spatial information). All methods agreed significantly better with CT than a reference water MRI comparison. The mean dosimetric deviation for photons and protons compared to the CT was about 2% and highest in the gradient dose region of the brainstem. Both the threshold based method and the statistical regression methods showed the highest dosimetrical agreement. Generation of pCTs using statistical regression seems to be the most promising candidate for MRI-only RT of the brain. Further, the total amount of different tissues needs to be taken into account for dosimetric considerations regardless of their correct geometrical position.

  5. High-Frequency Jet Ventilation for Complete Target Immobilization and Reduction of Planning Target Volume in Stereotactic High Single-Dose Irradiation of Stage I Non-Small Cell Lung Cancer and Lung Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, Peter, E-mail: p.h.fritz@t-online.d; Kraus, Hans-Joerg; Muehlnickel, Werner

    2010-09-01

    Purpose: To demonstrate the feasibility of complete target immobilization by means of high-frequency jet ventilation (HFJV); and to show that the saving of planning target volume (PTV) on the stereotactic body radiation therapy (SBRT) under HFJV, compared with SBRT with respiratory motion, can be predicted with reliable accuracy by computed tomography (CT) scans at peak inspiration phase. Methods and Materials: A comparison regarding different methods for defining the PTV was carried out in 22 patients with tumors that clearly moved with respiration. A movement span of the gross tumor volume (GTV) was defined by fusing respiration-correlated CT scans. The PTVmore » enclosed the GTV positions with a safety margin throughout the breathing cycle. To create a PTV from CT scans acquired under HFJV, the same margins were drawn around the immobilized target. In addition, peak inspiration phase CT images (PIP-CTs) were used to approximate a target immobilized by HFJV. Results: The resulting HFJV-PTVs were between 11.6% and 45.4% smaller than the baseline values calculated as respiration-correlated CT-PTVs (median volume reduction, 25.4%). Tentative planning by means of PIP-CT PTVs predicted that in 19 of 22 patients, use of HFJV would lead to a reduction in volume of {>=}20%. Using this threshold yielded a positive predictive value of 0.89, as well as a sensitivity of 0.94 and a specificity of 0.5. Conclusions: In all patients, SBRT under HFJV provided a reliable immobilization of the GTVs and achieved a reduction in PTVs, regardless of patient compliance. Tentative planning facilitated the selection of patients who could better undergo radiation in respiratory standstill, both with greater accuracy and lung protection.« less

  6. Remote sensing of aquatic vegetation distribution in Taihu Lake using an improved classification tree with modified thresholds.

    PubMed

    Zhao, Dehua; Jiang, Hao; Yang, Tangwu; Cai, Ying; Xu, Delin; An, Shuqing

    2012-03-01

    Classification trees (CT) have been used successfully in the past to classify aquatic vegetation from spectral indices (SI) obtained from remotely-sensed images. However, applying CT models developed for certain image dates to other time periods within the same year or among different years can reduce the classification accuracy. In this study, we developed CT models with modified thresholds using extreme SI values (CT(m)) to improve the stability of the models when applying them to different time periods. A total of 903 ground-truth samples were obtained in September of 2009 and 2010 and classified as emergent, floating-leaf, or submerged vegetation or other cover types. Classification trees were developed for 2009 (Model-09) and 2010 (Model-10) using field samples and a combination of two images from winter and summer. Overall accuracies of these models were 92.8% and 94.9%, respectively, which confirmed the ability of CT analysis to map aquatic vegetation in Taihu Lake. However, Model-10 had only 58.9-71.6% classification accuracy and 31.1-58.3% agreement (i.e., pixels classified the same in the two maps) for aquatic vegetation when it was applied to image pairs from both a different time period in 2010 and a similar time period in 2009. We developed a method to estimate the effects of extrinsic (EF) and intrinsic (IF) factors on model uncertainty using Modis images. Results indicated that 71.1% of the instability in classification between time periods was due to EF, which might include changes in atmospheric conditions, sun-view angle and water quality. The remainder was due to IF, such as phenological and growth status differences between time periods. The modified version of Model-10 (i.e. CT(m)) performed better than traditional CT with different image dates. When applied to 2009 images, the CT(m) version of Model-10 had very similar thresholds and performance as Model-09, with overall accuracies of 92.8% and 90.5% for Model-09 and the CT(m) version of Model-10, respectively. CT(m) decreased the variability related to EF and IF and thereby improved the applicability of the models to different time periods. In both practice and theory, our results suggested that CT(m) was more stable than traditional CT models and could be used to map aquatic vegetation in time periods other than the one for which the model was developed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Element-specific spectral imaging of multiple contrast agents: a phantom study

    NASA Astrophysics Data System (ADS)

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  8. Baseline Tumor Lipiodol Uptake after Transarterial Chemoembolization for Hepatocellular Carcinoma: Identification of a Threshold Value Predicting Tumor Recurrence.

    PubMed

    Matsui, Yusuke; Horikawa, Masahiro; Jahangiri Noudeh, Younes; Kaufman, John A; Kolbeck, Kenneth J; Farsad, Khashayar

    2017-12-01

    The aim of the study was to evaluate the association between baseline Lipiodol uptake in hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with early tumor recurrence, and to identify a threshold baseline uptake value predicting tumor response. A single-institution retrospective database of HCC treated with Lipiodol-TACE was reviewed. Forty-six tumors in 30 patients treated with a Lipiodol-chemotherapy emulsion and no additional particle embolization were included. Baseline Lipiodol uptake was measured as the mean Hounsfield units (HU) on a CT within one week after TACE. Washout rate was calculated dividing the difference in HU between the baseline CT and follow-up CT by time (HU/month). Cox proportional hazard models were used to correlate baseline Lipiodol uptake and other variables with tumor response. A receiver operating characteristic (ROC) curve was used to identify the optimal threshold for baseline Lipiodol uptake predicting tumor response. During the follow-up period (mean 5.6 months), 19 (41.3%) tumors recurred (mean time to recurrence = 3.6 months). In a multivariate model, low baseline Lipiodol uptake and higher washout rate were significant predictors of early tumor recurrence ( P = 0.001 and < 0.0001, respectively). On ROC analysis, a threshold Lipiodol uptake of 270.2 HU was significantly associated with tumor response (95% sensitivity, 93% specificity). Baseline Lipiodol uptake and washout rate on follow-up were independent predictors of early tumor recurrence. A threshold value of baseline Lipiodol uptake > 270.2 HU was highly sensitive and specific for tumor response. These findings may prove useful for determining subsequent treatment strategies after Lipiodol TACE.

  9. Midline Shift Threshold Value for Hemiparesis in Chronic Subdural Hematoma.

    PubMed

    Juković, Mirela F; Stojanović, Dejan B

    2015-01-01

    Chronic subdural hematoma (CSDH) has a variety of clinical presentations, with numerous neurological symptoms and signs. Hemiparesis is one of the leading signs that potentially indicates CSDH. Purpose of this study was to determine the threshold (cut-off) value of midsagittal line (MSL) shift after which hemiparesis is likely to appear. The study evaluated 83 patients with 53 unilateral and 30 bilateral CSDHs in period of three years. Evaluated computed tomography (CT) findings in patients with CSDH were diameter of the hematoma and midsagittal line shift, measured on non-contrast CT scan in relation with occurrence of hemiparesis. Threshold values of MSL shift for both types of CSDHs were obtained as maximal (equal) sensitivity and specificity (intersection of the curves). MSL is a good predictor for hemiparesis occurrence (total sample, AUROC 0.75, p=0.0001). Unilateral and bilateral CSDHs had different threshold values of the MSL for hemiparesis development. Results suggested that in unilateral CSDH the threshold values of MSL could be at 10 mm (AUROC=0.65; p=0.07). For bilateral CSDH the threshold level of MSL shift was 4.5 mm (AUROC=0.77; p=0.01). Our study pointed on the phenomenon that midsagittal line shift can predict hemiparesis occurrence. Hemiparesis in patients with bilateral CSDH was more related to midsagittal line shift compared with unilateral CSDH. When value of midsagittal line shift exceed the threshold level, hemiparesis occurs with certain probability.

  10. Comparison of an adaptive local thresholding method on CBCT and µCT endodontic images

    NASA Astrophysics Data System (ADS)

    Michetti, Jérôme; Basarab, Adrian; Diemer, Franck; Kouame, Denis

    2018-01-01

    Root canal segmentation on cone beam computed tomography (CBCT) images is difficult because of the noise level, resolution limitations, beam hardening and dental morphological variations. An image processing framework, based on an adaptive local threshold method, was evaluated on CBCT images acquired on extracted teeth. A comparison with high quality segmented endodontic images on micro computed tomography (µCT) images acquired from the same teeth was carried out using a dedicated registration process. Each segmented tooth was evaluated according to volume and root canal sections through the area and the Feret’s diameter. The proposed method is shown to overcome the limitations of CBCT and to provide an automated and adaptive complete endodontic segmentation. Despite a slight underestimation (-4, 08%), the local threshold segmentation method based on edge-detection was shown to be fast and accurate. Strong correlations between CBCT and µCT segmentations were found both for the root canal area and diameter (respectively 0.98 and 0.88). Our findings suggest that combining CBCT imaging with this image processing framework may benefit experimental endodontology, teaching and could represent a first development step towards the clinical use of endodontic CBCT segmentation during pulp cavity treatment.

  11. Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center

    PubMed Central

    Santana, Priscila do Carmo; de Oliveira, Paulo Marcio Campos; Mamede, Marcelo; Silveira, Mariana de Castro; Aguiar, Polyanna; Real, Raphaela Vila; da Silva, Teógenes Augusto

    2015-01-01

    Objective To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. PMID:25798004

  12. Adding bevacizumab to single agent chemotherapy for the treatment of platinum-resistant recurrent ovarian cancer: A cost effectiveness analysis of the AURELIA trial.

    PubMed

    Wysham, Weiya Z; Schaffer, Elisabeth M; Coles, Theresa; Roque, Dario R; Wheeler, Stephanie B; Kim, Kenneth H

    2017-05-01

    AURELIA, a randomized phase III trial of adding bevacizumab (B) to single agent chemotherapy (CT) for the treatment of platinum-resistant recurrent ovarian cancer, demonstrated improved progression free survival (PFS) in the B+CT arm compared to CT alone. We aimed to evaluate the cost effectiveness of adding B to CT in the treatment of platinum-resistant recurrent ovarian cancer. A decision tree model was constructed to evaluate the cost effectiveness of adding bevacizumab (B) to single agent chemotherapy (CT) based on the arms of the AURELIA trial. Costs, quality-adjusted life years (QALYs), and progression free survival (PFS) were modeled over fifteen months. Model inputs were extracted from published literature and public sources. Incremental cost effectiveness ratios (ICERs) per QALY gained and ICERs per progression free life year saved (PF-LYS) were calculated. One-way sensitivity analyses were performed to evaluate the robustness of results. The ICER associated with B+CT is $410,455 per QALY gained and $217,080 per PF-LYS. At a willingness to pay (WTP) threshold of $50,000/QALY, adding B to single agent CT is not cost effective for this patient population. Even at a WTP threshold of $100,000/QALY, B+CT is not cost effective. These findings are robust to sensitivity analyses. Despite gains in QALY and PFS, the addition of B to single agent CT for treatment of platinum-resistant recurrent ovarian cancer is not cost effective. Benefits, risks, and costs associated with treatment should be taken into consideration when prescribing chemotherapy for this patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Feasibility of tissue characterization of coronary plaques using 320-detector row computed tomography: comparison with integrated backscatter intravascular ultrasound.

    PubMed

    Takahashi, Shigekiyo; Kawasaki, Masanori; Miyata, Shusaku; Suzuki, Keita; Yamaura, Makoto; Ido, Takahisa; Aoyama, Takuma; Fujiwara, Hisayoshi; Minatoguchi, Shinya

    2016-01-01

    Recently, a new generation of multi-detector row computed tomography (CT) with 320-detector rows (DR) has become available in the clinical settings. The purpose of the present study was to determine the cutoff values of Hounsfield unit (HU) for discrimination of plaque components by comparing HU of coronary plaques with integrated backscatter intravascular ultrasound (IB-IVUS) serving as a gold standard. Seventy-seven coronary atherosclerotic lesions in 77 patients with angina were visualized by both 320-DR CT (Aquilion One, Toshiba, Japan) and IB-IVUS at the same site. To determine the thresholds for discrimination of plaque components, we compared HU with IB values as a gold standard. Optimal thresholds were determined from receiver operating characteristic (ROC) curves analysis. The HU values of lipid pool (n = 115), fibrosis (n = 93), vessel lumen and calcification (n = 73) were 28 ± 19 HU (range -18 to 69 HU), 98 ± 31 HU (44 to 195 HU), 357 ± 65 HU (227 to 534 HU) and 998 ± 236 HU (366 to 1,489 HU), respectively. The thresholds of 56 HU, 210 HU and 490 HU were the most reliable predictors of lipid pool, fibrosis, vessel lumen and calcification, respectively. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS (r = 0.63, p < 0.05), whereas fibrous volume measured by 320-DR CT was not. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS, whereas fibrous volume was not correlated with that measured by IB-IVUS because manual exclusion of the outside of vessel hindered rigorous discrimination between fibrosis and extravascular components.

  14. Mathematical Model of Naive T Cell Division and Survival IL-7 Thresholds.

    PubMed

    Reynolds, Joseph; Coles, Mark; Lythe, Grant; Molina-París, Carmen

    2013-01-01

    We develop a mathematical model of the peripheral naive T cell population to study the change in human naive T cell numbers from birth to adulthood, incorporating thymic output and the availability of interleukin-7 (IL-7). The model is formulated as three ordinary differential equations: two describe T cell numbers, in a resting state and progressing through the cell cycle. The third is introduced to describe changes in IL-7 availability. Thymic output is a decreasing function of time, representative of the thymic atrophy observed in aging humans. Each T cell is assumed to possess two interleukin-7 receptor (IL-7R) signaling thresholds: a survival threshold and a second, higher, proliferation threshold. If the IL-7R signaling strength is below its survival threshold, a cell may undergo apoptosis. When the signaling strength is above the survival threshold, but below the proliferation threshold, the cell survives but does not divide. Signaling strength above the proliferation threshold enables entry into cell cycle. Assuming that individual cell thresholds are log-normally distributed, we derive population-average rates for apoptosis and entry into cell cycle. We have analyzed the adiabatic change in homeostasis as thymic output decreases. With a parameter set representative of a healthy individual, the model predicts a unique equilibrium number of T cells. In a parameter range representative of persistent viral or bacterial infection, where naive T cell cycle progression is impaired, a decrease in thymic output may result in the collapse of the naive T cell repertoire.

  15. Preliminary study on the diagnostic value of single-source dual-energy CT in diagnosing cervical lymph node metastasis of thyroid carcinoma

    PubMed Central

    Zhao, Yanfeng; Li, Xiaolu; Wang, Xiaoyi; Lin, Meng; Zhao, Xinming; Luo, Dehong; Li, Jianying

    2017-01-01

    Background To investigate the value of single-source dual-energy spectral CT imaging in improving the accuracy of preoperative diagnosis of lymph node metastasis of thyroid carcinoma. Methods Thirty-four thyroid carcinoma patients were enrolled and received spectral CT scanning before thyroidectomy and cervical lymph node dissection surgery. Iodine-based material decomposition (MD) images and 101 sets of monochromatic images from 40 to 140 keV were reconstructed after CT scans. The iodine concentrations (IC) of lymph nodes were measured on the MD images and was normalized to that of common carotid artery to obtain the normalized iodine concentration (NIC). The CT number of lymph nodes as function of photon energy was measured on the 101 sets of images to generate a spectral HU curve and to calculate its slope λHU. The measurements between the metastatic and non-metastatic lymph nodes were statistically compared and receiver operating characteristic (ROC) curves were used to determine the optimal thresholds of these measurements for diagnosing lymph nodes metastasis. Results There were 136 lymph nodes that were pathologically confirmed. Among them, 102 (75%) were metastatic and 34 (25%) were non-metastatic. The IC, NIC and the slope λHU of the metastatic lymph nodes were 3.93±1.58 mg/mL, 0.70±0.55 and 4.63±1.91, respectively. These values were statistically higher than the respective values of 1.77±0.71 mg/mL, 0.29±0.16 and 2.19±0.91 for the non-metastatic lymph nodes (all P<0.001). ROC analysis determined the optimal diagnostic threshold for IC as 2.56 mg/mL, with the sensitivity, specificity and accuracy of 83.3%, 91.2% and 85.3%, respectively. The optimal threshold for NIC was 0.289, with the sensitivity, specificity and accuracy of 96.1%, 76.5% and 91.2%, respectively. The optimal threshold for the spectral curve slope λHU was 2.692, with the sensitivity, specificity and accuracy of 88.2%, 82.4% and 86.8%, respectively. Conclusions The measurements obtained in dual-energy spectral CT improve the sensitivity and accuracy for preoperatively diagnosing lymph node metastasis in thyroid carcinoma. PMID:29268547

  16. A prototype system for forecasting landslides in the Seattle, Washington, area

    USGS Publications Warehouse

    Chleborad, Alan F.; Baum, Rex L.; Godt, Jonathan W.; Powers, Philip S.

    2008-01-01

    Empirical rainfall thresholds and related information form the basis of a prototype system for forecasting landslides in the Seattle area. The forecasts are tied to four alert levels, and a decision tree guides the use of thresholds to determine the appropriate level. From analysis of historical landslide data, we developed a formula for a cumulative rainfall threshold (CT), P3  =  88.9 − 0.67P15, defined by rainfall amounts in millimeters during consecutive 3 d (72 h) periods, P3, and the 15 d (360 h) period before P3, P15. The variable CT captures more than 90% of historical events of three or more landslides in 1 d and 3 d periods recorded from 1978 to 2003. However, the low probability of landslide occurrence on a day when the CT is exceeded at one or more rain gauges (8.4%) justifies a low-level of alert for possible landslide occurrence, but it does trigger more vigilant monitoring of rainfall and soil wetness. Exceedance of a rainfall intensity-duration threshold I  =  82.73D−1.13, for intensity, I (mm/hr), and duration, D (hr), corresponds to a higher probability of landslide occurrence (30%) and forms the basis for issuing warnings of impending, widespread occurrence of landslides. Information about the area of exceedance and soil wetness can be used to increase the certainty of landslide forecasts (probabilities as great as 71%). Automated analysis of real-time rainfall and subsurface water data and digital quantitative precipitation forecasts are needed to fully implement a warning system based on the two thresholds.

  17. Use of an Internal Positive Control in a Multiplex Reverse Transcription-PCR To Detect West Nile Virus RNA in Mosquito Pools

    PubMed Central

    Eisler, Diane L.; McNabb, Alan; Jorgensen, Danielle R.; Isaac-Renton, Judith L.

    2004-01-01

    We report on the use of West Nile virus Armored RNA as an internal positive control (IPC) for the extraction and reverse transcription-PCR (RT-PCR) of RNA extracted from field-collected mosquitoes and on a multiplex real-time Taqman RT-PCR to simultaneously detect the 3′ noncoding region of West Nile virus and the West Nile virus NS5-2 region comprising the IPC. Mosquito pools from the province of British Columbia, Canada (n = 635), were tested in duplicate and found to be negative for West Nile virus and positive for the IPC. Known West Nile virus-positive supernatants from mosquito pools from the provinces of Alberta and Manitoba were tested in duplicate and found to be positive for both regions of the West Nile virus genome. The mean cycle threshold (Ct) value for the IPC in batch extraction controls ± 2 standard deviations was found to be 36.43 ± 1.78 cycles. IPCs of 98.4% (624) of West Nile virus-negative pools fell within this range, indicating the reproducibility of RNA extraction and RT-PCR for pools varying in mosquito genus and number. A comparison of mosquito pool genera revealed no significant genus effect on the Ct value of the IPC. The incorporation of West Nile virus Armored RNA as an IPC allows monitoring of RNA extraction and RT-PCR and detection of false-negative results due to failures in these processes or to PCR inhibition, respectively. PMID:14766868

  18. Diffuse Large B-Cell Lymphoma: Prospective Multicenter Comparison of Early Interim FLT PET/CT versus FDG PET/CT with IHP, EORTC, Deauville, and PERCIST Criteria for Early Therapeutic Monitoring

    PubMed Central

    Minamimoto, Ryogo; Fayad, Luis; Advani, Ranjana; Vose, Julie; Macapinlac, Homer; Meza, Jane; Hankins, Jordan; Mottaghy, Felix; Juweid, Malik

    2016-01-01

    Purpose To compare the performance characteristics of interim fluorine 18 (18F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (after two cycles of chemotherapy) by using the most prominent standardized interpretive criteria (including International Harmonization Project [IHP] criteria, European Organization for Research and Treatment of Cancer [EORTC] criteria, and PET Response Criteria in Solid Tumors (PERCIST) versus those of interim 18F fluorothymidine (FLT) PET/CT and simple visual interpretation. Materials and Methods This HIPAA-compliant prospective study was approved by the institutional review boards, and written informed consent was obtained. Patients with newly diagnosed diffuse large B-cell lymphoma (DLBCL) underwent both FLT and FDG PET/CT 18–24 days after two cycles of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone or rituximab, etoposide, prednisone, vincristine, cyclophosphamide, and doxorubicin. For FDG PET/CT interpretation, IHP criteria, EORTC criteria, PERCIST, Deauville criteria, standardized uptake value, total lesion glycolysis, and metabolic tumor volume were used. FLT PET/CT images were interpreted with visual assessment by two reviewers in consensus. The interim (after cycle 2) FDG and FLT PET/CT studies were then compared with the end-of-treatment FDG PET/CT studies to determine which interim examination and/or criteria best predicted the result after six cycles of chemotherapy. Results From November 2011 to May 2014, there were 60 potential patients for inclusion, of whom 46 patients (24 men [mean age, 60.9 years ± 13.7; range, 28–78 years] and 22 women [mean age, 57.2 years ± 13.4; range, 25–76 years]) fulfilled the criteria. Thirty-four patients had complete response, and 12 had residual disease at the end of treatment. FLT PET/CT had a significantly higher positive predictive value (PPV) (91%) in predicting residual disease than did any FDG PET/CT interpretation method (42%–46%). No difference in negative predictive value (NPV) was found between FLT PET/CT (94%) and FDG PET/CT (82%–95%), regardless of the interpretive criteria used. FLT PET/CT showed statistically higher (P < .001–.008) or similar NPVs than did FDG PET/CT. Conclusion Early interim FLT PET/CT had a significantly higher PPV than standardized FDG PET/CT–based interpretation for therapeutic response assessment in DLBCL. © RSNA, 2016 Online supplemental material is available for this article. PMID:26854705

  19. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nawfel, RD; Young, G

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dosemore » metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.« less

  20. The volume threshold of 300 versus 100 ml/day for chest tube removal after pulmonary lobectomy: a meta-analysis.

    PubMed

    Zhang, Tian-Xiang; Zhang, Ye; Liu, Zhi-Dong; Zhou, Shi-Jie; Xu, Shao-Fa

    2018-05-07

    In this meta-analysis, we conducted a pooled analysis of clinical studies comparing the efficacy of a volume threshold of 300 ml/day before removing a chest tube (CT) versus 100 ml/day after a lobectomy. According to the recommendations of the Cochrane Collaboration, we established a rigorous study protocol. We performed a systematic electronic search of PubMed, Embase, Cochrane Library, Web of Science databases, CNKI, the Wanfang database, CBMdisc and Google Scholar to identify articles to include in our meta-analysis. A literature search was performed using relevant keywords. A meta-analysis was performed using RevMan© software. Five studies, published between 2014 and 2015, including 615 patients (314 patients who had the CT removed when daily drainage was <300 ml and 301 patients who had the CT removed when daily drainage was <100 ml) met the selection criteria. From the available data, the patients using the volume threshold of 300 ml/day had a significantly decreased duration of drainage [MD = -44.07; 95% confidence interval (CI) -64.45 to -23.68; P < 0.0001] and hospital stay after operation (MD = -2.25; 95% CI -3.52 to -0.97; P = 0.0006) compared with patients using a volume threshold of 100 ml/day after a pulmonary lobectomy. However, no significant differences were observed in postoperative complications, such as pleural fluid reaccumulation [Odds ratio (OR) = 1.73; 95% CI = 0.74-4.07; P = 0.21] and atelectasis (OR = 0.97; 95% CI = 0.52-1.81; P = 0.93). Thoracentesis rates after removing the CT also showed no significant difference (OR = 1.53; 95% CI 0.55-4.22; P = 0.41). Our results showed that a higher volume threshold, up to 300 ml/day, is effective in reducing hospitalization times and duration of drainage in patients who undergo a lobectomy. Moreover, the volume threshold of 300 ml/day does not increase the occurrence of postoperative atelectasis, pleural fluid reaccumulation and thoracentesis rates. However, this review is limited by the methodological quality of the included trials, and additional studies according to the recommendations of Cochrane Library are appreciated.

  1. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun

    2008-12-15

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACTmore » from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma ({gamma}) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass {gamma} criteria. The average maximum and mean {gamma} indices were very low (well below 1), indicating good agreement between dose distributions. Increasing the cine duration generally increased the dose agreement. In the follow-up study, 49 of 50 patients had 100% of points within the PTV pass the {gamma} criteria. The average maximum and mean {gamma} indices were again well below 1, indicating good agreement. Dose calculation on RACT from cine CT is negligibly different from dose calculation on RACT from 4D-CT. Differences can be decreased further by increasing the cine duration of the cine CT scan.« less

  2. Evaluation of BD MAX Staph SR Assay for Differentiating Between Staphylococcus aureus and Coagulase-Negative Staphylococci and Determining Methicillin Resistance Directly From Positive Blood Cultures.

    PubMed

    Lee, Jaewoong; Park, Yeon Joon; Park, Dong Jin; Park, Kang Gyun; Lee, Hae Kyung

    2017-01-01

    We evaluated the performance of the BD MAX StaphSR Assay (SR assay; BD, USA) for direct detection of Staphylococcus aureus and methicillin resistance not only in S. aureus but also in coagulase-negative Staphylococci (CNS) from positive blood cultures. From 228 blood culture bottles, 103 S. aureus [45 methicillin-resistant S. aureus (MRSA), 55 methicillin-susceptible S. aureus (MSSA), 3 mixed infections (1 MRSA+Enterococcus faecalis, 1 MSSA+MRCNS, 1 MSSA+MSCNS)], and 125 CNS (102 MRCNS, 23 MSCNS) were identified by Vitek 2. For further analysis, we obtained the cycle threshold (Ct) values from the BD MAX system software to determine an appropriate cutoff value. For discrepancy analysis, conventional mecA/mecC PCR and oxacillin minimum inhibitory concentrations (MICs) were determined. Compared to Vitek 2, the SR assay identified all 103 S. aureus isolates correctly but failed to detect methicillin resistance in three MRSA isolates. All 55 MSSA isolates were correctly identified by the SR assay. In the concordant cases, the highest Ct values for nuc, mecA, and mec right-extremity junction (MREJ) were 25.6, 22, and 22.2, respectively. Therefore, we selected Ct values from 0-27 as a range of positivity, and applying this cutoff, the sensitivity/specificity of the SR assay were 100%/100% for detecting S. aureus, and 97.9%/98.1% and 99.0%/95.8% for detecting methicillin resistance in S. aureus and CNS, respectively. We propose a Ct cutoff value for nuc/mec assay without considering MREJ because mixed cultures of MSSA and MRCNS were very rare (0.4%) in the positive blood cultures.

  3. Computer-aided diagnosis of lung cancer: definition and detection of ground-glass opacity type of nodules by high-resolution computed tomography.

    PubMed

    Okada, Tohru; Iwano, Shingo; Ishigaki, Takeo; Kitasaka, Takayuki; Hirano, Yasushi; Mori, Kensaku; Suenaga, Yasuhito; Naganawa, Shinji

    2009-02-01

    The ground-glass opacity (GGO) of lung cancer is identified only subjectively on computed tomography (CT) images as no quantitative characteristic has been defined for GGOs. We sought to define GGOs quantitatively and to differentiate between GGOs and solid-type lung cancers semiautomatically with a computer-aided diagnosis (CAD). High-resolution CT images of 100 pulmonary nodules (all peripheral lung cancers) were collected from our clinical records. Two radiologists traced the contours of nodules and distinguished GGOs from solid areas. The CT attenuation value of each area was measured. Differentiation between cancer types was assessed by a receiver-operating characteristic (ROC) analysis. The mean CT attenuation of the GGO areas was -618.4 +/- 212.2 HU, whereas that of solid areas was -68.1 +/- 230.3 HU. CAD differentiated between solidand GGO-type lung cancers with a sensitivity of 86.0% and specificity of 96.5% when the threshold value was -370 HU. Four nodules of mixed GGOs were incorrectly classified as the solid type. CAD detected 96.3% of GGO areas when the threshold between GGO and solid areas was 194 HU. Objective definition of GGO area by CT attenuation is feasible. This method is useful for semiautomatic differentiation between GGOs and solid types of lung cancer.

  4. Spontaneous Subarachnoid Hemorrhage: A Systematic Review and Meta-analysis Describing the Diagnostic Accuracy of History, Physical Examination, Imaging, and Lumbar Puncture With an Exploration of Test Thresholds.

    PubMed

    Carpenter, Christopher R; Hussain, Adnan M; Ward, Michael J; Zipfel, Gregory J; Fowler, Susan; Pines, Jesse M; Sivilotti, Marco L A

    2016-09-01

    Spontaneous subarachnoid hemorrhage (SAH) is a rare, but serious etiology of headache. The diagnosis of SAH is especially challenging in alert, neurologically intact patients, as missed or delayed diagnosis can be catastrophic. The objective was to perform a diagnostic accuracy systematic review and meta-analysis of history, physical examination, cerebrospinal fluid (CSF) tests, computed tomography (CT), and clinical decision rules for spontaneous SAH. A secondary objective was to delineate probability of disease thresholds for imaging and lumbar puncture (LP). PubMed, Embase, Scopus, and research meeting abstracts were searched up to June 2015 for studies of emergency department patients with acute headache clinically concerning for spontaneous SAH. QUADAS-2 was used to assess study quality and, when appropriate, meta-analysis was conducted using random effects models. Outcomes were sensitivity, specificity, and positive (LR+) and negative (LR-) likelihood ratios. To identify test and treatment thresholds, we employed the Pauker-Kassirer method with Bernstein test indication curves using the summary estimates of diagnostic accuracy. A total of 5,022 publications were identified, of which 122 underwent full-text review; 22 studies were included (average SAH prevalence = 7.5%). Diagnostic studies differed in assessment of history and physical examination findings, CT technology, analytical techniques used to identify xanthochromia, and criterion standards for SAH. Study quality by QUADAS-2 was variable; however, most had a relatively low risk of biases. A history of neck pain (LR+ = 4.1; 95% confidence interval [CI] = 2.2 to 7.6) and neck stiffness on physical examination (LR+ = 6.6; 95% CI = 4.0 to 11.0) were the individual findings most strongly associated with SAH. Combinations of findings may rule out SAH, yet promising clinical decision rules await external validation. Noncontrast cranial CT within 6 hours of headache onset accurately ruled in (LR+ = 230; 95% CI = 6 to 8,700) and ruled out SAH (LR- = 0.01; 95% CI = 0 to 0.04); CT beyond 6 hours had a LR- of 0.07 (95% CI = 0.01 to 0.61). CSF analyses had lower diagnostic accuracy, whether using red blood cell (RBC) count or xanthochromia. At a threshold RBC count of 1,000 × 10(6) /L, the LR+ was 5.7 (95% CI = 1.4 to 23) and LR- was 0.21 (95% CI = 0.03 to 1.7). Using the pooled estimates of diagnostic accuracy and testing risks and benefits, we estimate that LP only benefits CT-negative patients when the pre-LP probability of SAH is on the order of 5%, which corresponds to a pre-CT probability greater than 20%. Less than one in 10 headache patients concerning for SAH are ultimately diagnosed with SAH in recent studies. While certain symptoms and signs increase or decrease the likelihood of SAH, no single characteristic is sufficient to rule in or rule out SAH. Within 6 hours of symptom onset, noncontrast cranial CT is highly accurate, while a negative CT beyond 6 hours substantially reduces the likelihood of SAH. LP appears to benefit relatively few patients within a narrow pretest probability range. With improvements in CT technology and an expanding body of evidence, test thresholds for LP may become more precise, obviating the need for a post-CT LP in more acute headache patients. Existing SAH clinical decision rules await external validation, but offer the potential to identify subsets most likely to benefit from post-CT LP, angiography, or no further testing. © 2016 by the Society for Academic Emergency Medicine.

  5. Forecasting Corrosion of Steel in Concrete Introducing Chloride Threshold Dependence on Steel Potential

    NASA Astrophysics Data System (ADS)

    Sanchez, Andrea Nathalie

    Corrosion initiates in reinforced concrete structures exposed to marine environments when the chloride ion concentration at the surface of an embedded steel reinforcing bar exceeds the chloride corrosion threshold (CT) value. The value of CT is generally assumed to have a conservative fixed value ranging from 0.2% to - 0.5 % of chloride ions by weight of cement. However, extensive experimental investigations confirmed that C T is not a fixed value and that the value of CT depends on many variables. Among those, the potential of passive steel embedded in concrete is a key influential factor on the value of CT and has received little attention in the literature. The phenomenon of a potential-dependent threshold (PDT) permits accounting for corrosion macrocell coupling between active and passive steel assembly components in corrosion forecast models, avoiding overly conservative long-term damage projections and leading to more efficient design. The objectives of this investigation was to 1) expand by a systematic experimental assessment the knowledge and data base on how dependent the chloride threshold is on the potential of the steel embedded in concrete and 2) introduce the chloride threshold dependence on steel potential as an integral part of corrosion-related service life prediction of reinforced concrete structures. Experimental assessments on PDT were found in the literature but for a limited set of conditions. Therefore, experiments were conducted with mortar and concrete specimens and exposed to conditions more representative of the field than those previously available. The experimental results confirmed the presence of the PDT effect and provided supporting information to use a value of -550 mV per decade of Cl- for the cathodic prevention slope betaCT, a critical quantitative input for implementation in a practical model. A refinement of a previous corrosion initiation-propagation model that incorporated PDT in a partially submerged reinforced concrete column in sea water was developed. Corrosion was assumed to start when the chloride corrosion threshold was reached in an active steel zone of a given size, followed by recalculating the potential distribution and update threshold values over the entire system at each time step. Notably, results of this work indicated that when PDT is ignored, as is the case in present forecasting model practice, the corrosion damage prediction can be overly conservative which could lead to structural overdesign or misguided future damage management planning. Implementation of PDT in next-generation models is therefore highly desirable. However, developing a mathematical model that forecasts the corrosion damage of an entire marine structure with a fully implemented PDT module can result in excessive computational complexity. Hence, a provisional simplified approach for incorporating the effect of PDT was developed. The approach uses a correction function to be applied to projections that have been computed using the traditional procedures.

  6. Repeated cycles of 5-fluorouracil chemotherapy impaired anti-tumor functions of cytotoxic T cells in a CT26 tumor-bearing mouse model.

    PubMed

    Wu, Yanhong; Deng, Zhenling; Wang, Huiru; Ma, Wenbo; Zhou, Chunxia; Zhang, Shuren

    2016-09-20

    Recently, the immunostimulatory roles of chemotherapeutics have been increasingly revealed, although bone marrow suppression is still a common toxicity of chemotherapy. While the numbers and ratios of different immune subpopulations are analyzed after chemotherapy, changes to immune status after each cycle of treatment are less studied and remain unclear. To determine the tumor-specific immune status and functions after different cycles of chemotherapy, we treated CT26 tumor-bearing mice with one to four cycles of 5-fluorouracil (5-FU). Overall survival was not improved when more than one cycle of 5-FU was administered. Here we present data concerning the immune statuses after one and three cycles of chemotherapy. We analyzed the amount of spleen cells from mice treated with one and three cycles of 5-FU as well as assayed their proliferation and cytotoxicity against the CT26 tumor cell line. We found that the absolute numbers of CD8 T-cells and NK cells were not influenced significantly after either one or three cycles of chemotherapy. However, after three cycles of 5-FU, proliferated CD8 T-cells were decreased, and CT26-specific cytotoxicity and IFN-γ secretion of spleen cells were impaired in vitro. After one cycle of 5-FU, there was a greater percentage of tumor infiltrating CD8 T-cells. In addition, more proliferated CD8 T-cells, enhanced tumor-specific cytotoxicity as well as IFN-γ secretion of spleen cells against CT26 in vitro were observed. Given the increased expression of immunosuppressive factors, such as PD-L1 and TGF-β, we assessed the effect of early introduction of immunotherapy in combination with chemotherapy. We found that mice treated with cytokine induced killer cells and PD-L1 monoclonal antibodies after one cycle of 5-FU had a better anti-tumor performance than those treated with chemotherapy or immunotherapy alone. These data suggest that a single cycle of 5-FU treatment promoted an anti-tumor immune response, whereas repeated chemotherapy cycles impaired anti-tumor immune functions. Though the amount of immune cells could recover after chemotherapy suspension, their anti-tumor functions were damaged by multiple rounds of chemotherapy. These findings also point towards early implementation of immunotherapy to improve the anti-tumor effect.

  7. Light-Induced resetting of the circadian pacemaker: quantitative analysis of transient versus steady-state phase shifts.

    PubMed

    Watanabe, K; Deboer, T; Meijer, J H

    2001-12-01

    The suprachiasmatic nuclei of the hypothalamus contain the major circadian pacemaker in mammals, driving circadian rhythms in behavioral and physiological functions. This circadian pacemaker's responsiveness to light allows synchronization to the light-dark cycle. Phase shifting by light often involves several transient cycles in which the behavioral activity rhythm gradually shifts to its steady-state position. In this article, the authors investigate in Syrian hamsters whether a phase-advancing light pulse results in immediate shifts of the PRC at the next circadian cycle. In a first series of experiments, the authors aimed a light pulse at CT 19 to induce a phase advance. It appeared that the steady-state phase advances were highly correlated with activity onset in the first and second transient cycle. This enabled them to make a reliable estimate of the steady-state phase shift induced by a phase-advancing light pulse on the basis of activity onset in the first transient cycle. In the next series of experiments, they presented a light pulse at CT 19, which was followed by a second light pulse aimed at the delay zone of the PRC on the next circadian cycle. The immediate and steady-state phase delays induced by the second light pulse were compared with data from a third experiment in which animals received a phase-delaying light pulse only. The authors observed that the waveform of the phase-delay part of the PRC (CT 12-16) obtained in Experiment 2 was virtually identical to the phase-delay part of the PRC for a single light pulse (obtained in Experiment 3). This finding allowed for a quantitative assessment of the data. The analysis indicates that the delay part of the PRC-between CT 12 and CT 16-is rapidly reset following a light pulse at CT 19. These findings complement earlier findings in the hamster showing that after a light pulse at CT 19, the phase-advancing part of the PRC is immediately shifted. Together, the data indicate that the basis for phase advancing involves rapid resetting of both advance and delay components of the PRC.

  8. A feature alignment score for online cone-beam CT-based image-guided radiotherapy for prostate cancer.

    PubMed

    Hargrave, Catriona; Deegan, Timothy; Poulsen, Michael; Bednarz, Tomasz; Harden, Fiona; Mengersen, Kerrie

    2018-05-17

    To develop a method for scoring online cone-beam CT (CBCT)-to-planning CT image feature alignment to inform prostate image-guided radiotherapy (IGRT) decision-making. The feasibility of incorporating volume variation metric thresholds predictive of delivering planned dose into weighted functions, was investigated. Radiation therapists and radiation oncologists participated in workshops where they reviewed prostate CBCT-IGRT case examples and completed a paper-based survey of image feature matching practices. For 36 prostate cancer patients, one daily CBCT was retrospectively contoured then registered with their plan to simulate delivered dose if (a) no online setup corrections and (b) online image alignment and setup corrections, were performed. Survey results were used to select variables for inclusion in classification and regression tree (CART) and boosted regression trees (BRT) modeling of volume variation metric thresholds predictive of delivering planned dose to the prostate, proximal seminal vesicles (PSV), bladder, and rectum. Weighted functions incorporating the CART and BRT results were used to calculate a score of individual tumor and organ at risk image feature alignment (FAS TV _ OAR ). Scaled and weighted FAS TV _ OAR were then used to calculate a score of overall treatment compliance (FAS global ) for a given CBCT-planning CT registration. The FAS TV _ OAR were assessed for sensitivity, specificity, and predictive power. FAS global thresholds indicative of high, medium, or low overall treatment plan compliance were determined using coefficients from multiple linear regression analysis. Thirty-two participants completed the prostate CBCT-IGRT survey. While responses demonstrated consensus of practice for preferential ranking of planning CT and CBCT match features in the presence of deformation and rotation, variation existed in the specified thresholds for observed volume differences requiring patient repositioning or repeat bladder and bowel preparation. The CART and BRT modeling indicated that for a given registration, a Dice similarity coefficient >0.80 and >0.60 for the prostate and PSV, respectively, and a maximum Hausdorff distance <8.0 mm for both structures were predictive of delivered dose ± 5% of planned dose. A normalized volume difference <1.0 and a CBCT anterior rectum wall >1.0 mm anterior to the planning CT anterior rectum wall were predictive of delivered dose >5% of planned rectum dose. A normalized volume difference <0.88, and a CBCT bladder wall >13.5 mm inferior and >5.0 mm posterior to the planning CT bladder were predictive of delivered dose >5% of planned bladder dose. A FAS TV _ OAR >0 is indicative of delivery of planned dose. For calculated FAS TV _ OAR for the prostate, PSV, bladder, and rectum using test data, sensitivity was 0.56, 0.75, 0.89, and 1.00, respectively; specificity 0.90, 0.94, 0.59, and 1.00, respectively; positive predictive power 0.90, 0.86, 0.53, and 1.00, respectively; and negative predictive power 0.56, 0.89, 0.91, and 1.00, respectively. Thresholds for the calculated FAS global of were low <60, medium 60-80, and high >80, with a 27% misclassification rate for the test data. A FAS global incorporating nested FAS TV _ OAR and volume variation metric thresholds predictive of treatment plan compliance was developed, offering an alternative to pretreatment dose calculations to assess treatment delivery accuracy. © 2018 American Association of Physicists in Medicine.

  9. Big data driven cycle time parallel prediction for production planning in wafer manufacturing

    NASA Astrophysics Data System (ADS)

    Wang, Junliang; Yang, Jungang; Zhang, Jie; Wang, Xiaoxi; Zhang, Wenjun Chris

    2018-07-01

    Cycle time forecasting (CTF) is one of the most crucial issues for production planning to keep high delivery reliability in semiconductor wafer fabrication systems (SWFS). This paper proposes a novel data-intensive cycle time (CT) prediction system with parallel computing to rapidly forecast the CT of wafer lots with large datasets. First, a density peak based radial basis function network (DP-RBFN) is designed to forecast the CT with the diverse and agglomerative CT data. Second, the network learning method based on a clustering technique is proposed to determine the density peak. Third, a parallel computing approach for network training is proposed in order to speed up the training process with large scaled CT data. Finally, an experiment with respect to SWFS is presented, which demonstrates that the proposed CTF system can not only speed up the training process of the model but also outperform the radial basis function network, the back-propagation-network and multivariate regression methodology based CTF methods in terms of the mean absolute deviation and standard deviation.

  10. Using biomarkers to predict TB treatment duration (Predict TB): a prospective, randomized, noninferiority, treatment shortening clinical trial.

    PubMed

    Chen, Ray Y; Via, Laura E; Dodd, Lori E; Walzl, Gerhard; Malherbe, Stephanus T; Loxton, André G; Dawson, Rodney; Wilkinson, Robert J; Thienemann, Friedrich; Tameris, Michele; Hatherill, Mark; Diacon, Andreas H; Liu, Xin; Xing, Jin; Jin, Xiaowei; Ma, Zhenya; Pan, Shouguo; Zhang, Guolong; Gao, Qian; Jiang, Qi; Zhu, Hong; Liang, Lili; Duan, Hongfei; Song, Taeksun; Alland, David; Tartakovsky, Michael; Rosenthal, Alex; Whalen, Christopher; Duvenhage, Michael; Cai, Ying; Goldfeder, Lisa C; Arora, Kriti; Smith, Bronwyn; Winter, Jill; Barry Iii, Clifton E

    2017-11-06

    Background : By the early 1980s, tuberculosis treatment was shortened from 24 to 6 months, maintaining relapse rates of 1-2%. Subsequent trials attempting shorter durations have failed, with 4-month arms consistently having relapse rates of 15-20%. One trial shortened treatment only among those without baseline cavity on chest x-ray and whose month 2 sputum culture converted to negative. The 4-month arm relapse rate decreased to 7% but was still significantly worse than the 6-month arm (1.6%, P<0.01).  We hypothesize that PET/CT characteristics at baseline, PET/CT changes at one month, and markers of residual bacterial load will identify patients with tuberculosis who can be cured with 4 months (16 weeks) of standard treatment. Methods : This is a prospective, multicenter, randomized, phase 2b, noninferiority clinical trial of pulmonary tuberculosis participants. Those eligible start standard of care treatment. PET/CT scans are done at weeks 0, 4, and 16 or 24. Participants who do not meet early treatment completion criteria (baseline radiologic severity, radiologic response at one month, and GeneXpert-detectable bacilli at four months) are placed in Arm A (24 weeks of standard therapy). Those who meet the early treatment completion criteria are randomized at week 16 to continue treatment to week 24 (Arm B) or complete treatment at week 16 (Arm C). The primary endpoint compares the treatment success rate at 18 months between Arms B and C. Discussion : Multiple biomarkers have been assessed to predict TB treatment outcomes. This study uses PET/CT scans and GeneXpert (Xpert) cycle threshold to risk stratify participants. PET/CT scans are not applicable to global public health but could be used in clinical trials to stratify participants and possibly become a surrogate endpoint. If the Predict TB trial is successful, other immunological biomarkers or transcriptional signatures that correlate with treatment outcome may be identified. NCT02821832.

  11. Direct comparison of Xpert MTB/RIF assay with liquid and solid mycobacterial culture for quantification of early bactericidal activity.

    PubMed

    Kayigire, Xavier A; Friedrich, Sven O; Venter, Amour; Dawson, Rodney; Gillespie, Stephen H; Boeree, Martin J; Heinrich, Norbert; Hoelscher, Michael; Diacon, Andreas H

    2013-06-01

    The early bactericidal activity of antituberculosis agents is usually determined by measuring the reduction of the sputum mycobacterial load over time on solid agar medium or in liquid culture. This study investigated the value of a quantitative PCR assay for early bactericidal activity determination. Groups of 15 patients were treated with 6 different antituberculosis agents or regimens. Patients collected sputum for 16 h overnight at baseline and at days 7 and 14 after treatment initiation. We determined the sputum bacterial load by CFU counting (log CFU/ml sputum, reported as mean ± standard deviation [SD]), time to culture positivity (TTP, in hours [mean ± SD]) in liquid culture, and Xpert MTB/RIF cycle thresholds (C(T), n [mean ± SD]). The ability to discriminate treatment effects between groups was analyzed with one-way analysis of variance (ANOVA). All measurements showed a decrease in bacterial load from mean baseline (log CFU, 5.72 ± 1.00; TTP, 116.0 ± 47.6; C(T), 19.3 ± 3.88) to day 7 (log CFU, -0.26 ± 1.23, P = 0.2112; TTP, 35.5 ± 59.3, P = 0.0002; C(T), 0.55 ± 3.07, P = 0.6030) and day 14 (log CFU, -0.55 ± 1.24, P = 0.0006; TTP, 54.8 ± 86.8, P < 0.0001; C(T), 2.06 ± 4.37, P = 0.0020). The best discrimination between group effects was found with TTP at day 7 and day 14 (F = 9.012, P < 0.0001, and F = 11.580, P < 0.0001), followed by log CFU (F = 4.135, P = 0.0024, and F = 7.277, P < 0.0001). C(T) was not significantly discriminative (F = 1.995, P = 0.091, and F = 1.203, P = 0.316, respectively). Culture-based methods are superior to PCR for the quantification of early antituberculosis treatment effects in sputum.

  12. Using biomarkers to predict TB treatment duration (Predict TB): a prospective, randomized, noninferiority, treatment shortening clinical trial

    PubMed Central

    Chen, Ray Y.; Via, Laura E.; Dodd, Lori E.; Walzl, Gerhard; Malherbe, Stephanus T.; Loxton, André G.; Dawson, Rodney; Wilkinson, Robert J.; Thienemann, Friedrich; Tameris, Michele; Hatherill, Mark; Diacon, Andreas H.; Liu, Xin; Xing, Jin; Jin, Xiaowei; Ma, Zhenya; Pan, Shouguo; Zhang, Guolong; Gao, Qian; Jiang, Qi; Zhu, Hong; Liang, Lili; Duan, Hongfei; Song, Taeksun; Alland, David; Tartakovsky, Michael; Rosenthal, Alex; Whalen, Christopher; Duvenhage, Michael; Cai, Ying; Goldfeder, Lisa C.; Arora, Kriti; Smith, Bronwyn; Winter, Jill; Barry III, Clifton E.

    2017-01-01

    Background: By the early 1980s, tuberculosis treatment was shortened from 24 to 6 months, maintaining relapse rates of 1-2%. Subsequent trials attempting shorter durations have failed, with 4-month arms consistently having relapse rates of 15-20%. One trial shortened treatment only among those without baseline cavity on chest x-ray and whose month 2 sputum culture converted to negative. The 4-month arm relapse rate decreased to 7% but was still significantly worse than the 6-month arm (1.6%, P<0.01).  We hypothesize that PET/CT characteristics at baseline, PET/CT changes at one month, and markers of residual bacterial load will identify patients with tuberculosis who can be cured with 4 months (16 weeks) of standard treatment. Methods: This is a prospective, multicenter, randomized, phase 2b, noninferiority clinical trial of pulmonary tuberculosis participants. Those eligible start standard of care treatment. PET/CT scans are done at weeks 0, 4, and 16 or 24. Participants who do not meet early treatment completion criteria (baseline radiologic severity, radiologic response at one month, and GeneXpert-detectable bacilli at four months) are placed in Arm A (24 weeks of standard therapy). Those who meet the early treatment completion criteria are randomized at week 16 to continue treatment to week 24 (Arm B) or complete treatment at week 16 (Arm C). The primary endpoint compares the treatment success rate at 18 months between Arms B and C. Discussion: Multiple biomarkers have been assessed to predict TB treatment outcomes. This study uses PET/CT scans and GeneXpert (Xpert) cycle threshold to risk stratify participants. PET/CT scans are not applicable to global public health but could be used in clinical trials to stratify participants and possibly become a surrogate endpoint. If the Predict TB trial is successful, other immunological biomarkers or transcriptional signatures that correlate with treatment outcome may be identified. Trial Registration: NCT02821832 PMID:29528048

  13. 3D-segmentation of the 18F-choline PET signal for target volume definition in radiation therapy of the prostate.

    PubMed

    Ciernik, I Frank; Brown, Derek W; Schmid, Daniel; Hany, Thomas; Egli, Peter; Davis, J Bernard

    2007-02-01

    Volumetric assessment of PET signals becomes increasingly relevant for radiotherapy (RT) planning. Here, we investigate the utility of 18F-choline PET signals to serve as a structure for semi-automatic segmentation for forward treatment planning of prostate cancer. 18F-choline PET and CT scans of ten patients with histologically proven prostate cancer without extracapsular growth were acquired using a combined PET/CT scanner. Target volumes were manually delineated on CT images using standard software. Volumes were also obtained from 18F-choline PET images using an asymmetrical segmentation algorithm. PTVs were derived from CT 18F-choline PET based clinical target volumes (CTVs) by automatic expansion and comparative planning was performed. As a read-out for dose given to non-target structures, dose to the rectal wall was assessed. Planning target volumes (PTVs) derived from CT and 18F-choline PET yielded comparable results. Optimal matching of CT and 18F-choline PET derived volumes in the lateral and cranial-caudal directions was obtained using a background-subtracted signal thresholds of 23.0+/-2.6%. In antero-posterior direction, where adaptation compensating for rectal signal overflow was required, optimal matching was achieved with a threshold of 49.5+/-4.6%. 3D-conformal planning with CT or 18F-choline PET resulted in comparable doses to the rectal wall. Choline PET signals of the prostate provide adequate spatial information amendable to standardized asymmetrical region growing algorithms for PET-based target volume definition for external beam RT.

  14. Effect of Short-Term, High-Intensity Exercise on Anaerobic Threshold in Women.

    ERIC Educational Resources Information Center

    Evans, Blanche W.

    This study investigated the effects of a six-week, high-intensity cycling program on anaerobic threshold (AT) in ten women. Subjects trained four days a week using high-intensity interval-type cycle exercises. Workouts included six 4-minute intervals cycling at 85 percent maximal oxygen uptake (VO sub 2 max), separated by 3-minute intervals of…

  15. Scatter and beam hardening reduction in industrial computed tomography using photon counting detectors

    NASA Astrophysics Data System (ADS)

    Schumacher, David; Sharma, Ravi; Grager, Jan-Carl; Schrapp, Michael

    2018-07-01

    Photon counting detectors (PCD) offer new possibilities for x-ray micro computed tomography (CT) in the field of non-destructive testing. For large and/or dense objects with high atomic numbers the problem of scattered radiation and beam hardening severely influences the image quality. This work shows that using an energy discriminating PCD based on CdTe allows to address these problems by intrinsically reducing both the influence of scattering and beam hardening. Based on 2D-radiographic measurements it is shown that by energy thresholding the influence of scattered radiation can be reduced by up to in case of a PCD compared to a conventional energy-integrating detector (EID). To demonstrate the capabilities of a PCD in reducing beam hardening, cupping artefacts are analyzed quantitatively. The PCD results show that the higher the energy threshold is set, the lower the cupping effect emerges. But since numerous beam hardening correction algorithms exist, the results of the PCD are compared to EID results corrected by common techniques. Nevertheless, the highest energy thresholds yield lower cupping artefacts than any of the applied correction algorithms. As an example of a potential industrial CT application, a turbine blade is investigated by CT. The inner structure of the turbine blade allows for comparing the image quality between PCD and EID in terms of absolute contrast, as well as normalized signal-to-noise and contrast-to-noise ratio. Where the absolute contrast can be improved by raising the energy thresholds of the PCD, it is found that due to lower statistics the normalized contrast-to-noise-ratio could not be improved compared to the EID. These results might change to the contrary when discarding pre-filtering of the x-ray spectra and thus allowing more low-energy photons to reach the detectors. Despite still being in the early phase in technological progress, PCDs already allow to improve CT image quality compared to conventional detectors in terms of scatter and beam hardening reduction.

  16. Accuracy of Rhenium-188 SPECT/CT activity quantification for applications in radionuclide therapy using clinical reconstruction methods.

    PubMed

    Esquinas, Pedro L; Uribe, Carlos F; Gonzalez, M; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2017-07-20

    The main applications of 188 Re in radionuclide therapies include trans-arterial liver radioembolization and palliation of painful bone-metastases. In order to optimize 188 Re therapies, the accurate determination of radiation dose delivered to tumors and organs at risk is required. Single photon emission computed tomography (SPECT) can be used to perform such dosimetry calculations. However, the accuracy of dosimetry estimates strongly depends on the accuracy of activity quantification in 188 Re images. In this study, we performed a series of phantom experiments aiming to investigate the accuracy of activity quantification for 188 Re SPECT using high-energy and medium-energy collimators. Objects of different shapes and sizes were scanned in Air, non-radioactive water (Cold-water) and water with activity (Hot-water). The ordered subset expectation maximization algorithm with clinically available corrections (CT-based attenuation, triple-energy window (TEW) scatter and resolution recovery was used). For high activities, the dead-time corrections were applied. The accuracy of activity quantification was evaluated using the ratio of the reconstructed activity in each object to this object's true activity. Each object's activity was determined with three segmentation methods: a 1% fixed threshold (for cold background), a 40% fixed threshold and a CT-based segmentation. Additionally, the activity recovered in the entire phantom, as well as the average activity concentration of the phantom background were compared to their true values. Finally, Monte-Carlo simulations of a commercial [Formula: see text]-camera were performed to investigate the accuracy of the TEW method. Good quantification accuracy (errors  <10%) was achieved for the entire phantom, the hot-background activity concentration and for objects in cold background segmented with a 1% threshold. However, the accuracy of activity quantification for objects segmented with 40% threshold or CT-based methods decreased (errors  >15%), mostly due to partial-volume effects. The Monte-Carlo simulations confirmed that TEW-scatter correction applied to 188 Re, although practical, yields only approximate estimates of the true scatter.

  17. A prospective gating method to acquire a diverse set of free-breathing CT images for model-based 4DCT

    NASA Astrophysics Data System (ADS)

    O'Connell, D.; Ruan, D.; Thomas, D. H.; Dou, T. H.; Lewis, J. H.; Santhanam, A.; Lee, P.; Low, D. A.

    2018-02-01

    Breathing motion modeling requires observation of tissues at sufficiently distinct respiratory states for proper 4D characterization. This work proposes a method to improve sampling of the breathing cycle with limited imaging dose. We designed and tested a prospective free-breathing acquisition protocol with a simulation using datasets from five patients imaged with a model-based 4DCT technique. Each dataset contained 25 free-breathing fast helical CT scans with simultaneous breathing surrogate measurements. Tissue displacements were measured using deformable image registration. A correspondence model related tissue displacement to the surrogate. Model residual was computed by comparing predicted displacements to image registration results. To determine a stopping criteria for the prospective protocol, i.e. when the breathing cycle had been sufficiently sampled, subsets of N scans where 5  ⩽  N  ⩽  9 were used to fit reduced models for each patient. A previously published metric was employed to describe the phase coverage, or ‘spread’, of the respiratory trajectories of each subset. Minimum phase coverage necessary to achieve mean model residual within 0.5 mm of the full 25-scan model was determined and used as the stopping criteria. Using the patient breathing traces, a prospective acquisition protocol was simulated. In all patients, phase coverage greater than the threshold necessary for model accuracy within 0.5 mm of the 25 scan model was achieved in six or fewer scans. The prospectively selected respiratory trajectories ranked in the (97.5  ±  4.2)th percentile among subsets of the originally sampled scans on average. Simulation results suggest that the proposed prospective method provides an effective means to sample the breathing cycle with limited free-breathing scans. One application of the method is to reduce the imaging dose of a previously published model-based 4DCT protocol to 25% of its original value while achieving mean model residual within 0.5 mm.

  18. Automatic delineation of functional lung volumes with 68Ga-ventilation/perfusion PET/CT.

    PubMed

    Le Roux, Pierre-Yves; Siva, Shankar; Callahan, Jason; Claudic, Yannis; Bourhis, David; Steinfort, Daniel P; Hicks, Rodney J; Hofman, Michael S

    2017-10-10

    Functional volumes computed from 68 Ga-ventilation/perfusion (V/Q) PET/CT, which we have shown to correlate with pulmonary function test parameters (PFTs), have potential diagnostic utility in a variety of clinical applications, including radiotherapy planning. An automatic segmentation method would facilitate delineation of such volumes. The aim of this study was to develop an automated threshold-based approach to delineate functional volumes that best correlates with manual delineation. Thirty lung cancer patients undergoing both V/Q PET/CT and PFTs were analyzed. Images were acquired following inhalation of Galligas and, subsequently, intravenous administration of 68 Ga-macroaggreted-albumin (MAA). Using visually defined manual contours as the reference standard, various cutoff values, expressed as a percentage of the maximal pixel value, were applied. The average volume difference and Dice similarity coefficient (DSC) were calculated, measuring the similarity of the automatic segmentation and the reference standard. Pearson's correlation was also calculated to compare automated volumes with manual volumes, and automated volumes optimized to PFT indices. For ventilation volumes, mean volume difference was lowest (- 0.4%) using a 15%max threshold with Pearson's coefficient of 0.71. Applying this cutoff, median DSC was 0.93 (0.87-0.95). Nevertheless, limits of agreement in volume differences were large (- 31.0 and 30.2%) with differences ranging from - 40.4 to + 33.0%. For perfusion volumes, mean volume difference was lowest and Pearson's coefficient was highest using a 15%max threshold (3.3% and 0.81, respectively). Applying this cutoff, median DSC was 0.93 (0.88-0.93). Nevertheless, limits of agreement were again large (- 21.1 and 27.8%) with volume differences ranging from - 18.6 to + 35.5%. Using the 15%max threshold, moderate correlation was demonstrated with FEV1/FVC (r = 0.48 and r = 0.46 for ventilation and perfusion images, respectively). No correlation was found between other PFT indices. To automatically delineate functional volumes with 68 Ga-V/Q PET/CT, the most appropriate cutoff was 15%max for both ventilation and perfusion images. However, using this unique threshold systematically provided unacceptable variability compared to the reference volume and relatively poor correlation with PFT parameters. Accordingly, a visually adapted semi-automatic method is favored, enabling rapid and quantitative delineation of lung functional volumes with 68 Ga-V/Q PET/CT.

  19. Dietary Influences on Alpha-Methylacyl-CoA Racemase (AMACR) Expression in the Prostate

    DTIC Science & Technology

    2007-04-01

    mRNA levels were calculated from the point where each curve crossed the threshold line (Ct) using the following equation : Rel. value = 2[Ct(control...Sunamura M, Horii A. Abrogation of DUSP6 by hypermethylation in human pancreatic cancer. J Hum Genet 2005;50:159–67. 41. Armes JE, Hammet F, de Silva M, et

  20. Latent class analysis of the diagnostic characteristics of PCR and conventional bacteriological culture in diagnosing intramammary infections caused by Staphylococcus aureus in dairy cows at dry off

    PubMed Central

    2012-01-01

    Background Staphylococcus aureus is one of the most common causes of intramammary infections in dairy cows at dry off. Reliable identification is important for disease management on herd level and for antimicrobial treatment of infected animals. Our objective was to evaluate the test characteristics of PathoProof ™ Mastitis PCR Assay and bacteriological culture (BC) in diagnosing bovine intramammary infections caused by S. aureus at dry off at different PCR cycle threshold (Ct)-value cut-offs. Methods Sterile quarter samples and non-sterile composite samples from 140 animals in seven herds were collected in connection with the dairy herd improvement (DHI) milk recording. All quarter samples were analyzed using BC whereas all composite samples were analyzed with PathoProof ™ Mastitis PCR Assay. Latent class analysis was used to estimate test properties for PCR and BC in the absence of a perfect reference test. The population was divided into two geographically divided subpopulations and the Hui-Walter 2-test 2-populations model applied to estimate Se, Sp for the two tests, and prevalence for the two subpopulations. Results The Se for PCR increased with increasing Ct-value cut-off, accompanied by a small decrease in Sp. For BC the Se decreased and Sp increased with increasing Ct-value cut-off. Most optimal test estimates for the real-time PCR assay were at a Ct-value cut-off of 37; 0.93 [95% posterior probability interval (PPI) 0.60-0.99] for Se and 0.95 [95% PPI 0.95-0.99] for Sp. At the same Ct-value cut-off, Se and Sp for BC were 0.83 [95% PPI 0.66-0.99] and 0.97 [95% PPI 0.91-0.99] respectively. Depending on the chosen PCR Ct-value cut-off, the prevalence in the subpopulations varied; the prevalence increased with increasing PCR Ct-value cut-offs. Conclusion Neither BC nor real-time PCR is a perfect test in detecting IMI in dairy cows at dry off. The changes in sensitivity and prevalence at different Ct-value cut-offs for both PCR and BC may indicate a change in the underlying disease definition. At low PCR Ct-value cut-offs the underlying disease definition may be a truly/heavily infected cow, whereas at higher PCR Ct-value cut-offs the disease definition may be a S. aureus positive cow. PMID:23164432

  1. Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT.

    PubMed

    Prell, D; Kalender, W A; Kyriakou, Y

    2010-12-01

    The purpose of this study was to develop, implement and evaluate a dedicated metal artefact reduction (MAR) method for flat-detector CT (FDCT). The algorithm uses the multidimensional raw data space to calculate surrogate attenuation values for the original metal traces in the raw data domain. The metal traces are detected automatically by a three-dimensional, threshold-based segmentation algorithm in an initial reconstructed image volume, based on twofold histogram information for calculating appropriate metal thresholds. These thresholds are combined with constrained morphological operations in the projection domain. A subsequent reconstruction of the modified raw data yields an artefact-reduced image volume that is further processed by a combining procedure that reinserts the missing metal information. For image quality assessment, measurements on semi-anthropomorphic phantoms containing metallic inserts were evaluated in terms of CT value accuracy, image noise and spatial resolution before and after correction. Measurements of the same phantoms without prostheses were used as ground truth for comparison. Cadaver measurements were performed on complex and realistic cases and to determine the influences of our correction method on the tissue surrounding the prostheses. The results showed a significant reduction of metal-induced streak artefacts (CT value differences were reduced to below 22 HU and image noise reduction of up to 200%). The cadaver measurements showed excellent results for imaging areas close to the implant and exceptional artefact suppression in these areas. Furthermore, measurements in the knee and spine regions confirmed the superiority of our method to standard one-dimensional, linear interpolation.

  2. Carbon cycling at the tipping point: Does ecosystem structure predict resistance to disturbance?

    NASA Astrophysics Data System (ADS)

    Gough, C. M.; Bond-Lamberty, B. P.; Stuart-Haentjens, E.; Atkins, J.; Haber, L.; Fahey, R. T.

    2017-12-01

    Ecosystems worldwide are subjected to disturbances that reshape their physical and biological structure and modify biogeochemical processes, including carbon storage and cycling rates. Disturbances, including those from insect pests, pathogens, and extreme weather, span a continuum of severity and, accordingly, may have different effects on carbon cycling processes. Some ecosystems resist biogeochemical changes following disturbance, until a critical threshold of severity is exceeded. The ecosystem properties underlying such functional resistance, and signifying when a tipping point will occur, however, are almost entirely unknown. Here, we present observational and experimental results from forests in the Great Lakes region, showing ecosystem structure is closely coupled with carbon cycling responses to disturbance, with shifts in structure predicting thresholds of and, in some cases, increases in carbon storage. We find, among forests in the region, that carbon storage regularly exhibits a non-linear threshold response to increasing disturbance levels, but the severity at which a threshold is reached varies among disturbed forests. More biologically and structurally complex forest ecosystems sometimes exhibit greater functional resistance than simpler forests, and consequently may have a higher disturbance severity threshold. Counter to model predictions but consistent with some theoretical frameworks, empirical data show moderate levels of disturbance may increase ecosystem complexity to a point, thereby increasing rates of carbon storage. Disturbances that increase complexity therefore may stimulate carbon storage, while severe disturbances at or beyond thresholds may simplify structure, leading to carbon storage declines. We conclude that ecosystem structural attributes are closely coupled with biogeochemical thresholds across disturbance severity gradients, suggesting that improved predictions of disturbance-related changes in the carbon cycle require better representation of ecosystem structure in models.

  3. [Analysis of the mRNA expression of the S100β protein in adipocytes of patients with diabetes mellitus, type 2].

    PubMed

    Hamasaki, Mike Yoshio; Hirata, Mario Hiroyuki; Hirata, Rosario Dominguez Crespo; Himelfarb, Silvia Tchernin; Campos, Leila Maria Guissoni; Nogueira, Maria Inês

    2012-10-01

    This study aims to explore the possible relationship between the expression level of S100β protein mRNA with diabetes mellitus type 2 in adipocytes from patients with this disease in comparison with normoglycemic individuals. Samples of adipose tissue of eight patients from the coronary section of the Institute Dante Pazzanese of Cardiology (IDPC), four in Group Diabetes and four of Normoglycemic group, were evaluated by RT-PCR real time. An increase around 15 times values, between the threshold cycle (ΔCt), of mRNA expression of S100β protein in adipocytes of the diabetes group was observed in comparison to the control group (p = 0.015). Our results indicate, for the first time, that there is coexistence of increased expression of the S100β and the type 2 diabetes mellitus gene.

  4. Pork detection in binary meat mixtures and some commercial food products using conventional and real-time PCR techniques.

    PubMed

    Al-Kahtani, Hassan A; Ismail, Elsayed A; Asif Ahmed, Mohammed

    2017-03-15

    Pork DNA was detected in meat mixtures using both conventional PCR and real-time PCR (RT-PCR). Thirty meat mixtures containing beef, chicken, camel, rabbit, goat and sheep with varying percentage of pork (0%, 1%, 5%, 10%, and 20%) and 75 commercial food products, were analyzed using conventional and RT-PCR to determine the presence of pork DNA. Pork DNA standard curves and cycle threshold (Ct) values were used for quantification. The detection limits for pork DNA in the mixtures were 0.22, 0.047, 0.048, 0.0000037, 0.015ng/μl respectively. Unlike conventional PCR, RT-PCR detected pork DNA in nine processed food samples [chicken sausages (2), chicken luncheon (2), turkey meat loaf, milk chocolate with soft nougat, jelly, cake, and candies] at pork DNA concentrations of 0.0001ng/μl or less. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Consolidation paclitaxel is more cost-effective than bevacizumab following upfront treatment of advanced epithelial ovarian cancer.

    PubMed

    Lesnock, Jamie L; Farris, Coreen; Krivak, Thomas C; Smith, Kenneth J; Markman, Maurie

    2011-09-01

    Randomized trials have demonstrated significant improvements in progression-free survival (PFS) with consolidation paclitaxel (P) and bevacizumab (B) following cytoreduction and adjuvant carboplatin/paclitaxel (CP) for advanced epithelial ovarian cancer (EOC). We sought to evaluate the cost-effectiveness (C/E) of these consolidation strategies. A decision model was developed based on Gynecologic Oncology Group (GOG) protocols #178 and #218. Arm 1 is 6 cycles of CP. Arm 2 is 6 cycles of CP followed by 12 cycles of P (CP+P). Arm 3 is 1 cycle of CP, 5 cycles of CPB, and 16 cycles of B (CPB+B). Parameters include PFS, overall survival (OS), cost, complications (neuropathy for P and bowel perforation for B), and quality-of-life utility values. Sensitivity analyses were performed. The incremental cost-effectiveness ratio (ICER) for CT+T is $13,402/quality adjusted life year (QALY) gained compared to CP. For CPB+B compared to CP, the ICER is $326,530/QALY. When compared simultaneously, CPB+B is dominated, i.e. is more costly and less effective than CP+P. Results were robust to parameter variation. At a willingness to pay threshold of $100,000/QALY, CP+P was the preferred option throughout most of the decision space. Sensitivity analyses suggest that CPB+B would become the preferred option if it were to improve OS by 6.1 years over CP+P. In this model, B consolidation for advanced EOC was associated with a modest improvement in effectiveness that is less than that with P consolidation and more costly. A statistically significant improvement in survival may improve the value of B consolidation. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Automated Protist Analysis of Complex Samples: Recent Investigations Using Motion and Thresholding

    DTIC Science & Technology

    2012-01-01

    Report No: CG-D-15-13 Automated Protist Analysis of Complex Samples: Recent Investigations Using Motion and Thresholding...Distribution Statement A: Approved for public release; distribution is unlimited. January 2012 Automated Protist Analysis of Complex Samples...Chelsea Street New London, CT 06320 Automated Protist Analysis of Complex Samples iii UNCLAS//PUBLIC | CG-926 R&DC | B. Nelson, et al

  7. Retrospective review of positron emission tomography with contrast-enhanced computed tomography in the posttreatment setting in human papillomavirus-associated oropharyngeal carcinoma.

    PubMed

    Chan, Jason Y K; Sanguineti, Giuseppe; Richmon, Jeremy D; Marur, Shanthi; Gourin, Christine G; Koch, Wayne; Chung, Christine H; Quon, Harry; Bishop, Justin A; Aygun, Nafi; Agrawal, Nishant

    2012-11-01

    To determine the value of positron emission tomography (PET) with contrast-enhanced computed tomography (CT) in assessing the need for neck dissection by retrospectively reviewing the pathology reports of patients with human papillomavirus (HPV)-associated oropharyngeal squamous cell carcinoma (SCC). Retrospective cohort study. Tertiary medical center. Seventy-seven patients with HPV-related SCC. Seventy-seven consecutive patients with a diagnosis of HPV-related SCC who were treated with radiotherapy as the primary treatment between August 2007 and October 2010 were retrospectively evaluated for radiologic and pathologic rate of persistence of nodal metastasis after completion of definitive radiotherapy. Pretreatment and posttreatment imaging included contrast-enhanced CT and PET. Response to treatment was measured on CT, PET at standardized uptake value (SUV) thresholds of 2 and 2.5, and PET/CT by a neuroradiologist in a blinded fashion. Then, the pathology report of the patients who underwent neck dissections was reviewed for nodal status after resection and correlated with the imaging findings. Of the 77 patients, 67 met the study criteria, with an average follow-up PET/CT scan at 90.5 days after completion of radiotherapy. Ten patients did not undergo follow-up PET/CT imaging. Twenty patients underwent neck dissections after completion of radiation therapy. Of these 20 patients, 4 had persistent tumor and 16 did not have viable tumor. Using the final pathology report to correlate with imaging responses, CT had a negative predictive value (NPV) of 85.7% (95% CI, 48.7%-97.4%), PET with SUV thresholds of 2 had an NPV of 91.7% (95% CI, 64.6%-98.5%), PET with a cutoff SUV of 2.5 had an NPV of 85.7% (95% CI, 60.1%-96.0%), PET/CT with an SUV of 2 had an NPV of 100% (95% CI, 59.8%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 85.7% (95% CI, 48.7%-97.4%). The 47 patients who did not undergo neck dissection had a median follow-up of 26 months without an isolated neck failure. Analysis of all 67 patients in the cohort revealed the following values: CT had an NPV of 95.7% (95% CI, 85.8%-98.8%), PET with an SUV of 2 had an NPV of 98.2% (95% CI, 90.4%-99.7%), PET with an SUV of 2.5 had an NPV of 95.0% (95% CI, 86.3%-98.3%), PET/CT with an SUV of 2 had an NPV of 100.0% (95% CI, 92.0%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 95.7% (95% CI, 85.8%-98.8%). Positron emission tomography combined with contrast-enhanced CT has a better NPV than either imaging modality alone in patients with HPV-associated oropharyngeal SCC. Furthermore, PET/CT with an SUV threshold of 2 used in patients with HPV-related SCC offers an imaging modality with a high NPV that may obviate the need for unnecessary neck dissections.

  8. Selection of Reference Genes for Quantitative Gene Expression in Porcine Mesenchymal Stem Cells Derived from Various Sources along with Differentiation into Multilineages

    PubMed Central

    Lee, Won-Jae; Jeon, Ryoung-Hoon; Jang, Si-Jung; Park, Ji-Sung; Lee, Seung-Chan; Baregundi Subbarao, Raghavendra; Lee, Sung-Lim; Park, Bong-Wook; King, William Allan; Rho, Gyu-Jin

    2015-01-01

    The identification of stable reference genes is a prerequisite for ensuring accurate validation of gene expression, yet too little is known about stable reference genes of porcine MSCs. The present study was, therefore, conducted to assess the stability of reference genes in porcine MSCs derived from bone marrow (BMSCs), adipose (AMSCs), and skin (SMSCs) with their in vitro differentiated cells into mesenchymal lineages such as adipocytes, osteocytes, and chondrocytes. Twelve commonly used reference genes were investigated for their threshold cycle (Ct) values by qRT-PCR. The Ct values of candidate reference genes were analyzed by geNorm software to clarify stable expression regardless of experimental conditions. Thus, Pearson's correlation was applied to determine correlation between the three most stable reference genes (NF3) and optimal number of reference genes (NFopt). In assessment of stability of reference gene across experimental conditions by geNorm analysis, undifferentiated MSCs and each differentiated status into mesenchymal lineages showed slightly different results but similar patterns about more or less stable rankings. Furthermore, Pearson's correlation revealed high correlation (r > 0.9) between NF3 and NFopt. Overall, the present study showed that HMBS, YWHAZ, SDHA, and TBP are suitable reference genes for qRT-PCR in porcine MSCs. PMID:25972899

  9. Normal Lung Quantification in Usual Interstitial Pneumonia Pattern: The Impact of Threshold-based Volumetric CT Analysis for the Staging of Idiopathic Pulmonary Fibrosis.

    PubMed

    Ohkubo, Hirotsugu; Kanemitsu, Yoshihiro; Uemura, Takehiro; Takakuwa, Osamu; Takemura, Masaya; Maeno, Ken; Ito, Yutaka; Oguri, Tetsuya; Kazawa, Nobutaka; Mikami, Ryuji; Niimi, Akio

    2016-01-01

    Although several computer-aided computed tomography (CT) analysis methods have been reported to objectively assess the disease severity and progression of idiopathic pulmonary fibrosis (IPF), it is unclear which method is most practical. A universal severity classification system has not yet been adopted for IPF. The purpose of this study was to test the correlation between quantitative-CT indices and lung physiology variables and to determine the ability of such indices to predict disease severity in IPF. A total of 27 IPF patients showing radiological UIP pattern on high-resolution (HR) CT were retrospectively enrolled. Staging of IPF was performed according to two classification systems: the Japanese and GAP (gender, age, and physiology) staging systems. CT images were assessed using a commercially available CT imaging analysis workstation, and the whole-lung mean CT value (MCT), the normally attenuated lung volume as defined from -950 HU to -701 Hounsfield unit (NL), the volume of the whole lung (WL), and the percentage of NL to WL (NL%), were calculated. CT indices (MCT, WL, and NL) closely correlated with lung physiology variables. Among them, NL strongly correlated with forced vital capacity (FVC) (r = 0.92, P <0.0001). NL% showed a large area under the receiver operating characteristic curve for detecting patients in the moderate or advanced stages of IPF. Multivariable logistic regression analyses showed that NL% is significantly more useful than the percentages of predicted FVC and predicted diffusing capacity of the lungs for carbon monoxide (Japanese stage II/III/IV [odds ratio, 0.73; 95% confidence intervals (CI), 0.48 to 0.92; P < 0.01]; III/IV [odds ratio. 0.80; 95% CI 0.59 to 0.96; P < 0.01]; GAP stage II/III [odds ratio, 0.79; 95% CI, 0.56 to 0.97; P < 0.05]). The measurement of NL% by threshold-based volumetric CT analysis may help improve IPF staging.

  10. Effect of exposure cycle on hot salt stress corrosion of a titanium alloy

    NASA Technical Reports Server (NTRS)

    Gray, H. R.; Johnston, J. R.

    1974-01-01

    The influence of exposure cycle on the hot-salt stress-corrosion cracking resistance of the Ti-8Al-1Mo-1V alloy was determined. Both temperature and stress were cycled simultaneously to simulate turbine-powered aircraft service cycles. Temperature and stress were also cycled independently to determine their individual effects. Substantial increases in crack threshold stresses were observed for cycles in which both temperature and stress or temperature alone were applied for 1 hour and removed for 3 hours. The crack threshold stresses for these cyclic exposures were twice those determined for continuous exposure for the same total time of 96 hours.

  11. TaqMan probe real-time polymerase chain reaction assay for the quantification of canine DNA in chicken nugget.

    PubMed

    Rahman, Md Mahfujur; Hamid, Sharifah Bee Abd; Basirun, Wan Jefrey; Bhassu, Subha; Rashid, Nur Raifana Abdul; Mustafa, Shuhaimi; Mohd Desa, Mohd Nasir; Ali, Md Eaqub

    2016-01-01

    This paper describes a short-amplicon-based TaqMan probe quantitative real-time PCR (qPCR) assay for the quantitative detection of canine meat in chicken nuggets, which are very popular across the world, including Malaysia. The assay targeted a 100-bp fragment of canine cytb gene using a canine-specific primer and TaqMan probe. Specificity against 10 different animals and plants species demonstrated threshold cycles (Ct) of 16.13 ± 0.12 to 16.25 ± 0.23 for canine DNA and negative results for the others in a 40-cycle reaction. The assay was tested for the quantification of up to 0.01% canine meat in deliberately spiked chicken nuggets with 99.7% PCR efficiency and 0.995 correlation coefficient. The analysis of the actual and qPCR predicted values showed a high recovery rate (from 87% ± 28% to 112% ± 19%) with a linear regression close to unity (R(2) = 0.999). Finally, samples of three halal-branded commercial chicken nuggets collected from different Malaysian outlets were screened for canine meat, but no contamination was demonstrated.

  12. Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.

    PubMed

    Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E

    2018-02-20

    Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2  > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.

  13. Conspicuity of renal calculi at unenhanced CT: effects of calculus composition and size and CT technique.

    PubMed

    Tublin, Mitchell E; Murphy, Michael E; Delong, David M; Tessler, Franklin N; Kliewer, Mark A

    2002-10-01

    To determine the effects of calculus size, composition, and technique (kilovolt and milliampere settings) on the conspicuity of renal calculi at unenhanced helical computed tomography (CT). The authors performed unenhanced CT of a phantom containing 188 renal calculi of varying size and chemical composition (brushite, cystine, struvite, weddellite, whewellite, and uric acid) at 24 combinations of four kilovolt (80-140 kV) and six milliampere (200-300 mA) levels. Two radiologists, who were unaware of the location and number of calculi, reviewed the CT images and recorded where stones were detected. These observations were compared with the known positions of calculi to generate true-positive and false-positive rates. Logistic regression analysis was performed to investigate the effects of stone size, composition, and technique and to generate probability estimates of detection. Interobserver agreement was estimated with kappa statistics. Interobserver agreement was high: the mean kappa value for the two observers was 0.86. The conspicuity of stone fragments increased with increasing kilovolt and milliampere levels for all stone types. At the highest settings (140 kV and 300 mA), the detection threshold size (ie, the size of calculus that had a 50% probability of being detected) ranged from 0.81 mm + 0.03 (weddellite) to 1.3 mm + 0.1 (uric acid). Detection threshold size for each type of calculus increased up to 1.17-fold at lower kilovolt settings and up to 1.08-fold at lower milliampere settings. The conspicuity of small renal calculi at CT increases with higher kilovolt and milliampere settings, with higher kilovolts being particularly important. Small uric acid calculi may be imperceptible, even with maximal CT technique.

  14. SU-F-J-113: Multi-Atlas Based Automatic Organ Segmentation for Lung Radiotherapy Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J; Han, J; Ailawadi, S

    Purpose: Normal organ segmentation is one time-consuming and labor-intensive step for lung radiotherapy treatment planning. The aim of this study is to evaluate the performance of a multi-atlas based segmentation approach for automatic organs at risk (OAR) delineation. Methods: Fifteen Lung stereotactic body radiation therapy patients were randomly selected. Planning CT images and OAR contours of the heart - HT, aorta - AO, vena cava - VC, pulmonary trunk - PT, and esophagus – ES were exported and used as reference and atlas sets. For automatic organ delineation for a given target CT, 1) all atlas sets were deformably warpedmore » to the target CT, 2) the deformed sets were accumulated and normalized to produce organ probability density (OPD) maps, and 3) the OPD maps were converted to contours via image thresholding. Optimal threshold for each organ was empirically determined by comparing the auto-segmented contours against their respective reference contours. The delineated results were evaluated by measuring contour similarity metrics: DICE, mean distance (MD), and true detection rate (TD), where DICE=(intersection volume/sum of two volumes) and TD = {1.0 - (false positive + false negative)/2.0}. Diffeomorphic Demons algorithm was employed for CT-CT deformable image registrations. Results: Optimal thresholds were determined to be 0.53 for HT, 0.38 for AO, 0.28 for PT, 0.43 for VC, and 0.31 for ES. The mean similarity metrics (DICE[%], MD[mm], TD[%]) were (88, 3.2, 89) for HT, (79, 3.2, 82) for AO, (75, 2.7, 77) for PT, (68, 3.4, 73) for VC, and (51,2.7, 60) for ES. Conclusion: The investigated multi-atlas based approach produced reliable segmentations for the organs with large and relatively clear boundaries (HT and AO). However, the detection of small and narrow organs with diffused boundaries (ES) were challenging. Sophisticated atlas selection and multi-atlas fusion algorithms may further improve the quality of segmentations.« less

  15. TU-H-207A-03: CT Hounsfield Unit Accuracy: Effect of Beam Hardening On Phantom and Clinical Whole-Body CT Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ai, H; Wendt, R

    2016-06-15

    Purpose: To assess the effect of beam hardening on measured CT HU values. Methods: An anthropomorphic knee phantom was scanned with the CT component of a GE Discovery 690 PET/CT scanner (120kVp, 300mAs, 40?0.625mm collimation, pitch=0.984, FOV=500mm, matrix=512?512) with four different scan setups, each of which induces different degrees of beam hardening by introducing additional attenuation media into the field of view. Homogeneous voxels representing “soft tissue” and “bone” were segmented by HU thresholding followed by a 3D morphological erosion operation which removes the non-homogenous voxels located on the interface of thresholded tissue mask. HU values of segmented “soft tissue”more » and “bone” were compared.Additionally, whole-body CT data with coverage from the skull apex to the end of toes were retrospectively retrieved from seven PET/CT exams to evaluate the effect of beam hardening in vivo. Homogeneous bone voxels were segmented with the same method previously described. Total In-Slice Attenuation (TISA) for each CT slice, defined as the summation of HU values over all voxels within a CT slice, was calculated for all slices of the seven whole-body CT datasets and evaluated against the mean HU values of homogeneous bone voxels within that slice. Results: HU values measured from the phantom showed that while “soft tissue” HU values were unaffected, added attenuation within the FOV caused noticeable decreases in the measured HU values of “bone” voxels. A linear relationship was observed between bone HU and TISA for slices of the torso and legs, but not of the skull. Conclusion: Beam hardening effect is not an issue of concern for voxels with HU in the soft tissue range, but should not be neglected for bone voxels. A linear relationship exists between bone HU and the associated TISA in non-skull CT slices, which can be exploited to develop a correction strategy.« less

  16. Metal Artifact Reduction in X-ray Computed Tomography Using Computer-Aided Design Data of Implants as Prior Information.

    PubMed

    Ruth, Veikko; Kolditz, Daniel; Steiding, Christian; Kalender, Willi A

    2017-06-01

    The performance of metal artifact reduction (MAR) methods in x-ray computed tomography (CT) suffers from incorrect identification of metallic implants in the artifact-affected volumetric images. The aim of this study was to investigate potential improvements of state-of-the-art MAR methods by using prior information on geometry and material of the implant. The influence of a novel prior knowledge-based segmentation (PS) compared with threshold-based segmentation (TS) on 2 MAR methods (linear interpolation [LI] and normalized-MAR [NORMAR]) was investigated. The segmentation is the initial step of both MAR methods. Prior knowledge-based segmentation uses 3-dimensional registered computer-aided design (CAD) data as prior knowledge to estimate the correct position and orientation of the metallic objects. Threshold-based segmentation uses an adaptive threshold to identify metal. Subsequently, for LI and NORMAR, the selected voxels are projected into the raw data domain to mark metal areas. Attenuation values in these areas are replaced by different interpolation schemes followed by a second reconstruction. Finally, the previously selected metal voxels are replaced by the metal voxels determined by PS or TS in the initial reconstruction. First, we investigated in an elaborate phantom study if the knowledge of the exact implant shape extracted from the CAD data provided by the manufacturer of the implant can improve the MAR result. Second, the leg of a human cadaver was scanned using a clinical CT system before and after the implantation of an artificial knee joint. The results were compared regarding segmentation accuracy, CT number accuracy, and the restoration of distorted structures. The use of PS improved the efficacy of LI and NORMAR compared with TS. Artifacts caused by insufficient segmentation were reduced, and additional information was made available within the projection data. The estimation of the implant shape was more exact and not dependent on a threshold value. Consequently, the visibility of structures was improved when comparing the new approach to the standard method. This was further confirmed by improved CT value accuracy and reduced image noise. The PS approach based on prior implant information provides image quality which is superior to TS-based MAR, especially when the shape of the metallic implant is complex. The new approach can be useful for improving MAR methods and dose calculations within radiation therapy based on the MAR corrected CT images.

  17. C-Tactile Mediated Erotic Touch Perception Relates to Sexual Desire and Performance in a Gender-Specific Way.

    PubMed

    Bendas, Johanna; Georgiadis, Janniko R; Ritschel, Gerhard; Olausson, Håkan; Weidner, Kerstin; Croy, Ilona

    2017-05-01

    Unmyelinated low-threshold mechanoreceptors-the so-called C-tactile (CT) afferents-play a crucial role in the perception and conduction of caressing and pleasant touch sensations and significantly contribute to the concept of erotic touch perception. To investigate the relations between sexual desire and sexual performance and the perception of touch mediated by CT afferents. Seventy healthy participants (28 men, 42 women; mean age ± SD = 24.84 ± 4.08 years, range = 18-36 years) underwent standardized and highly controlled stroking stimulation that varied in the amount of CT fiber stimulation by changing stroking velocity (CT optimal = 1, 3 and 10 cm/s; CT suboptimal = 0.1, 0.3, and 30 cm/s). Participants rated the perceived pleasantness, eroticism, and intensity of the applied tactile stimulation on a visual analog scale, completed the Sexual Desire Inventory, and answered questions about sexual performance. Ratings of perceived eroticism of touch were related to self-report levels of sexual desire and sexual performance. Pleasantness and eroticism ratings showed similar dependence on stroking velocity that aligned with the activity of CT afferents. Erotic touch perception was related to sexual desire and sexual performance in a gender-specific way. In women, differences in eroticism ratings between CT optimal and suboptimal velocities correlated positively with desire for sexual interaction. In contrast, in men, this difference correlated to a decreased frequency and longer duration of partnered sexual activities. The present results lay the foundation for future research assessing these relations in patients with specific impairments of sexual functioning (eg, hypoactive sexual desire disorder). The strength of the study is the combination of standardized neurophysiologic methods and behavioral data. A clear limitation of the study design is the exclusion of exact data on the female menstrual cycle and the recruitment of an inhomogeneous sample concerning sexual orientation. The present results provide further evidence that unmyelinated CT afferents play a role in the complex mechanism of erotic touch perception. The ability to differentiate between CT optimal and suboptimal stimuli relates to sexual desire and performance in a gender-specific way. Bendas J, Georgiadis JR, Ritschel G. C-Tactile Mediated Erotic Touch Perception Relates to Sexual Desire and Performance in a Gender-Specific Way. J Sex Med 2017;14:645-653. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  18. Respiratory Viral Detections During Symptomatic and Asymptomatic Periods in Young Andean Children

    PubMed Central

    Howard, Leigh M.; Johnson, Monika; Williams, John V.; Zhu, Yuwei; Gil, Ana I.; Edwards, Kathryn M.; Griffin, Marie R.; Lanata, Claudio F.; Grijalva, Carlos G.

    2015-01-01

    Background Viruses are commonly detected in children with acute respiratory illnesses (ARI) and in asymptomatic children. Longitudinal studies of viral detections during asymptomatic periods surrounding ARI could facilitate interpretation of viral detections but are currently scant. Methods We used reverse transcription-polymerase chain reaction (RT-PCR) to analyze respiratory samples from young Andean children for viruses during asymptomatic periods within 8-120 days of index ARI (cough or fever). We compared viral detections over time within children and explored RT-PCR cycle thresholds (CT) as surrogates for viral loads. Results At least one respiratory virus was detected in 367 (43%) of 859 samples collected during asymptomatic periods, with more frequent detections in periods with rhinorrhea (49%) than those without (34%, p<0.001). Relative to index ARI with human rhinovirus (HRV), adenovirus (AdV), respiratory syncytial virus (RSV), and parainfluenza virus (PIV) detected, the same virus was also detected during 32%, 22%, 10%, and 3% of asymptomatic periods, respectively. RSV was only detected 8-30 days after index RSV ARI, whereas HRV and AdV were detected throughout asymptomatic periods. Human metapneumovirus (MPV) and influenza were rarely detected during asymptomatic periods (<3%). No significant differences were observed in the CT for HRV or AdV during asymptomatic periods relative to ARI. For RSV, CT were significantly lower during ARI relative to the asymptomatic period (p=0.03). Conclusions These findings indicate that influenza, MPV, PIV, and RSV detections in children with ARI usually indicate a causal relationship. When HRV or AdV is detected during ARI, the causal relationship is less certain. PMID:26121205

  19. Real-Time PCR Detection of Paenibacillus spp. in Raw Milk To Predict Shelf Life Performance of Pasteurized Fluid Milk Products

    PubMed Central

    Ranieri, Matthew L.; Ivy, Reid A.; Mitchell, W. Robert; Call, Emma; Masiello, Stephanie N.; Wiedmann, Martin

    2012-01-01

    Psychrotolerant sporeformers, specifically Paenibacillus spp., are important spoilage bacteria for pasteurized, refrigerated foods such as fluid milk. While Paenibacillus spp. have been isolated from farm environments, raw milk, processing plant environments, and pasteurized fluid milk, no information on the number of Paenibacillus spp. that need to be present in raw milk to cause pasteurized milk spoilage was available. A real-time PCR assay targeting the 16S rRNA gene was designed to detect Paenibacillus spp. in fluid milk and to discriminate between Paenibacillus and other closely related spore-forming bacteria. Specificity was confirmed using 16 Paenibacillus and 17 Bacillus isolates. All 16 Paenibacillus isolates were detected with a mean cycle threshold (CT) of 19.14 ± 0.54. While 14/17 Bacillus isolates showed no signal (CT > 40), 3 Bacillus isolates showed very weak positive signals (CT = 38.66 ± 0.65). The assay provided a detection limit of approximately 3.25 × 101 CFU/ml using total genomic DNA extracted from raw milk samples inoculated with Paenibacillus. Application of the TaqMan PCR to colony lysates obtained from heat-treated and enriched raw milk provided fast and accurate detection of Paenibacillus. Heat-treated milk samples where Paenibacillus (≥1 CFU/ml) was detected by this colony TaqMan PCR showed high bacterial counts (>4.30 log CFU/ml) after refrigerated storage (6°C) for 21 days. We thus developed a tool for rapid detection of Paenibacillus that has the potential to identify raw milk with microbial spoilage potential as a pasteurized product. PMID:22685148

  20. Analysis of Diagnostic Findings From the European Mobile Laboratory in Guéckédou, Guinea, March 2014 Through March 2015.

    PubMed

    Kerber, Romy; Krumkamp, Ralf; Diallo, Boubacar; Jaeger, Anna; Rudolf, Martin; Lanini, Simone; Bore, Joseph Akoi; Koundouno, Fara Raymond; Becker-Ziaja, Beate; Fleischmann, Erna; Stoecker, Kilian; Meschi, Silvia; Mély, Stéphane; Newman, Edmund N C; Carletti, Fabrizio; Portmann, Jasmine; Korva, Misa; Wolff, Svenja; Molkenthin, Peter; Kis, Zoltan; Kelterbaum, Anne; Bocquin, Anne; Strecker, Thomas; Fizet, Alexandra; Castilletti, Concetta; Schudt, Gordian; Ottowell, Lisa; Kurth, Andreas; Atkinson, Barry; Badusche, Marlis; Cannas, Angela; Pallasch, Elisa; Bosworth, Andrew; Yue, Constanze; Pályi, Bernadett; Ellerbrok, Heinz; Kohl, Claudia; Oestereich, Lisa; Logue, Christopher H; Lüdtke, Anja; Richter, Martin; Ngabo, Didier; Borremans, Benny; Becker, Dirk; Gryseels, Sophie; Abdellati, Saïd; Vermoesen, Tine; Kuisma, Eeva; Kraus, Annette; Liedigk, Britta; Maes, Piet; Thom, Ruth; Duraffour, Sophie; Diederich, Sandra; Hinzmann, Julia; Afrough, Babak; Repits, Johanna; Mertens, Marc; Vitoriano, Inês; Bah, Amadou; Sachse, Andreas; Boettcher, Jan Peter; Wurr, Stephanie; Bockholt, Sabrina; Nitsche, Andreas; Županc, Tatjana Avšič; Strasser, Marc; Ippolito, Giuseppe; Becker, Stephan; Raoul, Herve; Carroll, Miles W; De Clerck, Hilde; Van Herp, Michel; Sprecher, Armand; Koivogui, Lamine; Magassouba, N'Faly; Keïta, Sakoba; Drury, Patrick; Gurry, Cèline; Formenty, Pierre; May, Jürgen; Gabriel, Martin; Wölfel, Roman; Günther, Stephan; Di Caro, Antonino

    2016-10-15

     A unit of the European Mobile Laboratory (EMLab) consortium was deployed to the Ebola virus disease (EVD) treatment unit in Guéckédou, Guinea, from March 2014 through March 2015.  The unit diagnosed EVD and malaria, using the RealStar Filovirus Screen reverse transcription-polymerase chain reaction (RT-PCR) kit and a malaria rapid diagnostic test, respectively.  The cleaned EMLab database comprised 4719 samples from 2741 cases of suspected EVD from Guinea. EVD was diagnosed in 1231 of 2178 hospitalized patients (57%) and in 281 of 563 who died in the community (50%). Children aged <15 years had the highest proportion of Ebola virus-malaria parasite coinfections. The case-fatality ratio was high in patients aged <5 years (80%) and those aged >74 years (90%) and low in patients aged 10-19 years (40%). On admission, RT-PCR analysis of blood specimens from patients who died in the hospital yielded a lower median cycle threshold (Ct) than analysis of blood specimens from survivors (18.1 vs 23.2). Individuals who died in the community had a median Ct of 21.5 for throat swabs. Multivariate logistic regression on 1047 data sets revealed that low Ct values, ages of <5 and ≥45 years, and, among children aged 5-14 years, malaria parasite coinfection were independent determinants of a poor EVD outcome.  Virus load, age, and malaria parasite coinfection play a role in the outcome of EVD. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.

  1. Analysis of Diagnostic Findings From the European Mobile Laboratory in Guéckédou, Guinea, March 2014 Through March 2015

    PubMed Central

    Kerber, Romy; Krumkamp, Ralf; Diallo, Boubacar; Jaeger, Anna; Rudolf, Martin; Lanini, Simone; Bore, Joseph Akoi; Koundouno, Fara Raymond; Becker-Ziaja, Beate; Fleischmann, Erna; Stoecker, Kilian; Meschi, Silvia; Mély, Stéphane; Newman, Edmund N. C.; Carletti, Fabrizio; Portmann, Jasmine; Korva, Misa; Wolff, Svenja; Molkenthin, Peter; Kis, Zoltan; Kelterbaum, Anne; Bocquin, Anne; Strecker, Thomas; Fizet, Alexandra; Castilletti, Concetta; Schudt, Gordian; Ottowell, Lisa; Kurth, Andreas; Atkinson, Barry; Badusche, Marlis; Cannas, Angela; Pallasch, Elisa; Bosworth, Andrew; Yue, Constanze; Pályi, Bernadett; Ellerbrok, Heinz; Kohl, Claudia; Oestereich, Lisa; Logue, Christopher H.; Lüdtke, Anja; Richter, Martin; Ngabo, Didier; Borremans, Benny; Becker, Dirk; Gryseels, Sophie; Abdellati, Saïd; Vermoesen, Tine; Kuisma, Eeva; Kraus, Annette; Liedigk, Britta; Maes, Piet; Thom, Ruth; Duraffour, Sophie; Diederich, Sandra; Hinzmann, Julia; Afrough, Babak; Repits, Johanna; Mertens, Marc; Vitoriano, Inês; Bah, Amadou; Sachse, Andreas; Boettcher, Jan Peter; Wurr, Stephanie; Bockholt, Sabrina; Nitsche, Andreas; Županc, Tatjana Avšič; Strasser, Marc; Ippolito, Giuseppe; Becker, Stephan; Raoul, Herve; Carroll, Miles W.; De Clerck, Hilde; Van Herp, Michel; Sprecher, Armand; Koivogui, Lamine; Magassouba, N'Faly; Keïta, Sakoba; Drury, Patrick; Gurry, Cèline; Formenty, Pierre; May, Jürgen; Gabriel, Martin; Wölfel, Roman; Günther, Stephan; Di Caro, Antonino

    2016-01-01

    Background. A unit of the European Mobile Laboratory (EMLab) consortium was deployed to the Ebola virus disease (EVD) treatment unit in Guéckédou, Guinea, from March 2014 through March 2015. Methods. The unit diagnosed EVD and malaria, using the RealStar Filovirus Screen reverse transcription–polymerase chain reaction (RT-PCR) kit and a malaria rapid diagnostic test, respectively. Results. The cleaned EMLab database comprised 4719 samples from 2741 cases of suspected EVD from Guinea. EVD was diagnosed in 1231 of 2178 hospitalized patients (57%) and in 281 of 563 who died in the community (50%). Children aged <15 years had the highest proportion of Ebola virus–malaria parasite coinfections. The case-fatality ratio was high in patients aged <5 years (80%) and those aged >74 years (90%) and low in patients aged 10–19 years (40%). On admission, RT-PCR analysis of blood specimens from patients who died in the hospital yielded a lower median cycle threshold (Ct) than analysis of blood specimens from survivors (18.1 vs 23.2). Individuals who died in the community had a median Ct of 21.5 for throat swabs. Multivariate logistic regression on 1047 data sets revealed that low Ct values, ages of <5 and ≥45 years, and, among children aged 5–14 years, malaria parasite coinfection were independent determinants of a poor EVD outcome. Conclusions. Virus load, age, and malaria parasite coinfection play a role in the outcome of EVD. PMID:27638946

  2. Attenuation correction of emission PET images with average CT: Interpolation from breath-hold CT

    NASA Astrophysics Data System (ADS)

    Huang, Tzung-Chi; Zhang, Geoffrey; Chen, Chih-Hao; Yang, Bang-Hung; Wu, Nien-Yun; Wang, Shyh-Jen; Wu, Tung-Hsin

    2011-05-01

    Misregistration resulting from the difference of temporal resolution in PET and CT scans occur frequently in PET/CT imaging, which causes distortion in tumor quantification in PET. Respiration cine average CT (CACT) for PET attenuation correction has been reported to improve the misalignment effectively by several papers. However, the radiation dose to the patient from a four-dimensional CT scan is relatively high. In this study, we propose a method to interpolate respiratory CT images over a respiratory cycle from inhalation and exhalation breath-hold CT images, and use the average CT from the generated CT set for PET attenuation correction. The radiation dose to the patient is reduced using this method. Six cancer patients of various lesion sites underwent routine free-breath helical CT (HCT), respiration CACT, interpolated average CT (IACT), and 18F-FDG PET. Deformable image registration was used to interpolate the middle phases of a respiratory cycle based on the end-inspiration and end-expiration breath-hold CT scans. The average CT image was calculated from the eight interpolated CT image sets of middle respiratory phases and the two original inspiration and expiration CT images. Then the PET images were reconstructed by these three methods for attenuation correction using HCT, CACT, and IACT. Misalignment of PET image using either CACT or IACT for attenuation correction in PET/CT was improved. The difference in standard uptake value (SUV) from tumor in PET images was most significant between the use of HCT and CACT, while the least significant between the use of CACT and IACT. Besides the similar improvement in tumor quantification compared to the use of CACT, using IACT for PET attenuation correction reduces the radiation dose to the patient.

  3. Correlation between carotid bifurcation calcium burden on non-enhanced CT and percentage stenosis, as confirmed by digital subtraction angiography

    PubMed Central

    Sarikaya, B; Lohman, B; Mckinney, A M; Gadani, S; Irfan, M; Lucato, L

    2012-01-01

    Objectives Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods 50 patients (aged 41–82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered “significant”. Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm3 were utilised and Pearson'S correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate–strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm3 was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a “score” that could predict high grade stenosis. PMID:21896662

  4. Exploiting the potential of free software to evaluate root canal biomechanical preparation outcomes through micro-CT images.

    PubMed

    Neves, A A; Silva, E J; Roter, J M; Belladona, F G; Alves, H D; Lopes, R T; Paciornik, S; De-Deus, G A

    2015-11-01

    To propose an automated image processing routine based on free software to quantify root canal preparation outcomes in pairs of sound and instrumented roots after micro-CT scanning procedures. Seven mesial roots of human mandibular molars with different canal configuration systems were studied: (i) Vertucci's type 1, (ii) Vertucci's type 2, (iii) two individual canals, (iv) Vertucci's type 6, canals (v) with and (vi) without debris, and (vii) canal with visible pulp calcification. All teeth were instrumented with the BioRaCe system and scanned in a Skyscan 1173 micro-CT before and after canal preparation. After reconstruction, the instrumented stack of images (IS) was registered against the preoperative sound stack of images (SS). Image processing included contrast equalization and noise filtering. Sound canal volumes were obtained by a minimum threshold. For the IS, a fixed conservative threshold was chosen as the best compromise between instrumented canal and dentine whilst avoiding debris, resulting in instrumented canal plus empty spaces. Arithmetic and logical operations between sound and instrumented stacks were used to identify debris. Noninstrumented dentine was calculated using a minimum threshold in the IS and subtracting from the SS and total debris. Removed dentine volume was obtained by subtracting SS from IS. Quantitative data on total debris present in the root canal space after instrumentation, noninstrumented areas and removed dentine volume were obtained for each test case, as well as three-dimensional volume renderings. After standardization of acquisition, reconstruction and image processing micro-CT images, a quantitative approach for calculation of root canal biomechanical outcomes was achieved using free software. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  5. New prospective 4D-CT for mitigating the effects of irregular respiratory motion

    NASA Astrophysics Data System (ADS)

    Pan, Tinsu; Martin, Rachael M.; Luo, Dershan

    2017-08-01

    Artifact caused by irregular respiration is a major source of error in 4D-CT imaging. We propose a new prospective 4D-CT to mitigate this source of error without new hardware, software or off-line data-processing on the GE CT scanner. We utilize the cine CT scan in the design of the new prospective 4D-CT. The cine CT scan at each position can be stopped by the operator when an irregular respiration occurs, and resumed when the respiration becomes regular. This process can be repeated at one or multiple scan positions. After the scan, a retrospective reconstruction is initiated on the CT console to reconstruct only the images corresponding to the regular respiratory cycles. The end result is a 4D-CT free of irregular respiration. To prove feasibility, we conducted a phantom and six patient studies. The artifacts associated with the irregular respiratory cycles could be removed from both the phantom and patient studies. A new prospective 4D-CT scanning and processing technique to mitigate the impact of irregular respiration in 4D-CT has been demonstrated. This technique can save radiation dose because the repeat scans are only at the scan positions where an irregular respiration occurs. Current practice is to repeat the scans at all positions. There is no cost to apply this technique because it is applicable on the GE CT scanner without new hardware, software or off-line data-processing.

  6. Fracture Prediction by Computed Tomography and Finite Element Analysis: Current and Future Perspectives.

    PubMed

    Johannesdottir, Fjola; Allaire, Brett; Bouxsein, Mary L

    2018-05-30

    This review critiques the ability of CT-based methods to predict incident hip and vertebral fractures. CT-based techniques with concurrent calibration all show strong associations with incident hip and vertebral fracture, predicting hip and vertebral fractures as well as, and sometimes better than, dual-energy X-ray absorptiometry areal biomass density (DXA aBMD). There is growing evidence for use of routine CT scans for bone health assessment. CT-based techniques provide a robust approach for osteoporosis diagnosis and fracture prediction. It remains to be seen if further technical advances will improve fracture prediction compared to DXA aBMD. Future work should include more standardization in CT analyses, establishment of treatment intervention thresholds, and more studies to determine whether routine CT scans can be efficiently used to expand the number of individuals who undergo evaluation for fracture risk.

  7. Ultimobranchial gland respond in a different way in male and female fresh water teleost Mastacembelus armatus (Lacepede) during reproductive cycle.

    PubMed

    Verma, Sushant Kumar; Alim, Abdul

    2015-05-01

    The present study was carried out to analyze the differences in the activity of ultimobranchial gland (UBG) between male and female fresh water teleost Mastacembelus armatus during reproductive cycle. Considerable variations in the nuclear diameter of UBG cells and plasma calcitonin (CT) levels during different reproductive phases of testicular and ovarian cycle suggested that the activity of the UBG depends upon the sexual maturity of fishes. A positive correlation was observed between plasma CT and sex steroid levels and the gonadosomatic index in both sexes which further confirmed the involvement of UBG in the processes related to gonadal development in fishes irrespective of the sex. Sudden increase in the level of plasma CT and nuclear diameter of UBG cells after administration of 17 α-methyltestosterone in males and 17 β-estradiol in females during resting phase of the reproductive cycle clearly showed that UBG becomes hyperactive with increases in the level of sex steroids. Plasma calcium level was also found to be positively correlated with gonadal maturation in females. However no such change in plasma calcium level in relation to testicular cycle was observed. Thus it can be concluded that UBG becomes hyperactive during gonadal maturation but its role differs between male and female fishes. In females it may involved in both gonadal maturation and plasma calcium regulation while in males its involvement in calcium regulation was not justified. Variations in the level of CT during various phases of testicular cycle evidenced its involvement in gonadal maturation only. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  9. Microstructure Evolution from X-CT Measurements for Concrete/mortar under Multi-actions of Composite Salts Dry-wet Cycles and Loading

    NASA Astrophysics Data System (ADS)

    Chen, Yanjuan; Gao, Jianming; Shen, Daman

    2017-08-01

    Inthis research, microstructure evolution forconcrete/mortar under multi-actions of composite salts dry-wet cycles and loading was investigated through X-CT measurements. The evolution process of pores and micro-cracking with the erosion time were tracked. Compared the different erosion actions, it was found that dry-wet cycles promoted the pores become connected gradually. Besides, the dry-wet cycles accelerated the damage seriously on interface area between concrete and aggregate, whistle, loading contributes to the cracking propagation toward the internal. Moreover, fly ash played a positive role in the increasing of the number of harmless holes again and contributed to the durability of concrete.

  10. Retrospective Review of Positron Emission Tomography With Contrast-Enhanced Computed Tomography in the Posttreatment Setting in Human Papillomavirus–Associated Oropharyngeal Carcinoma

    PubMed Central

    Chan, Jason Y. K.; Sanguineti, Giuseppe; Richmon, Jeremy D.; Marur, Shanthi; Gourin, Christine G.; Koch, Wayne; Chung, Christine H.; Quon, Harry; Bishop, Justin A.; Aygun, Nafi; Agrawal, Nishant

    2013-01-01

    Objective To determine the value of positron emission tomography (PET) with contrast-enhanced computed tomography (CT) in assessing the need for neck dissection by retrospectively reviewing the pathology reports of patients with human papillomavirus (HPV)- associated oropharyngeal squamous cell carcinoma (SCC). Design Retrospective cohort study. Setting Tertiary medical center. Patients Seventy-seven patients with HPV-related SCC. Main Outcome Measures Seventy-seven consecutive patients with a diagnosis of HPV-related SCC who were treated with radiotherapy as the primary treatment between August 2007 and October 2010 were retrospectively evaluated for radiologic and pathologic rate of persistence of nodal metastasis after completion of definitive radiotherapy. Pretreatment and posttreatment imaging included contrast-enhanced CT and PET. Response to treatment was measured on CT, PET at standardized uptake value (SUV) thresholds of 2 and 2.5, and PET/CT by a neuroradiologist in a blinded fashion. Then, the pathology report of the patients who underwent neck dissections was reviewed for nodal status after resection and correlated with the imaging findings. Results Of the 77 patients, 67 met the study criteria, with an average follow-up PET/CT scan at 90.5 days after completion of radiotherapy. Ten patients did not undergo follow-up PET/CT imaging. Twenty patients underwent neck dissections after completion of radiation therapy. Of these 20 patients, 4 had persistent tumor and 16 did not have viable tumor. Using the final pathology report to correlate with imaging responses, CT had a negative predictive value (NPV) of 85.7% (95% CI, 48.7%-97.4%), PET with SUV thresholds of 2 had an NPV of 91.7% (95% CI, 64.6%-98.5%), PET with a cutoff SUV of 2.5 had an NPV of 85.7% (95% CI, 60.1%-96.0%), PET/CT with an SUV of 2 had an NPV of 100% (95% CI, 59.8%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 85.7% (95% CI, 48.7%-97.4%). The 47 patients who did not undergo neck dissection had a median follow-up of 26 months without an isolated neck failure. Analysis of all 67 patients in the cohort revealed the following values: CT had an NPV of 95.7% (95% CI, 85.8%-98.8%), PET with an SUV of 2 had an NPV of 98.2% (95% CI, 90.4%-99.7%), PET with an SUV of 2.5 had an NPV of 95.0% (95% CI, 86.3%-98.3%), PET/CT with an SUV of 2 had an NPV of 100.0% (95% CI, 92.0%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 95.7% (95% CI, 85.8%-98.8%). Conclusions Positron emission tomography combined with contrast-enhanced CT has a better NPV than either imaging modality alone in patients with HPV-associated oropharyngeal SCC. Furthermore, PET/CT with an SUV threshold of 2 used in patients with HPV-related SCC offers an imaging modality with a high NPV that may obviate the need for unnecessary neck dissections. PMID:23165378

  11. Automatic estimation of detector radial position for contoured SPECT acquisition using CT images on a SPECT/CT system.

    PubMed

    Liu, Ruijie Rachel; Erwin, William D

    2006-08-01

    An algorithm was developed to estimate noncircular orbit (NCO) single-photon emission computed tomography (SPECT) detector radius on a SPECT/CT imaging system using the CT images, for incorporation into collimator resolution modeling for iterative SPECT reconstruction. Simulated male abdominal (arms up), male head and neck (arms down) and female chest (arms down) anthropomorphic phantom, and ten patient, medium-energy SPECT/CT scans were acquired on a hybrid imaging system. The algorithm simulated inward SPECT detector radial motion and object contour detection at each projection angle, employing the calculated average CT image and a fixed Hounsfield unit (HU) threshold. Calculated radii were compared to the observed true radii, and optimal CT threshold values, corresponding to patient bed and clothing surfaces, were found to be between -970 and -950 HU. The algorithm was constrained by the 45 cm CT field-of-view (FOV), which limited the detected radii to < or = 22.5 cm and led to occasional radius underestimation in the case of object truncation by CT. Two methods incorporating the algorithm were implemented: physical model (PM) and best fit (BF). The PM method computed an offset that produced maximum overlap of calculated and true radii for the phantom scans, and applied that offset as a calculated-to-true radius transformation. For the BF method, the calculated-to-true radius transformation was based upon a linear regression between calculated and true radii. For the PM method, a fixed offset of +2.75 cm provided maximum calculated-to-true radius overlap for the phantom study, which accounted for the camera system's object contour detect sensor surface-to-detector face distance. For the BF method, a linear regression of true versus calculated radius from a reference patient scan was used as a calculated-to-true radius transform. Both methods were applied to ten patient scans. For -970 and -950 HU thresholds, the combined overall average root-mean-square (rms) error in radial position for eight patient scans without truncation were 3.37 cm (12.9%) for PM and 1.99 cm (8.6%) for BF, indicating BF is superior to PM in the absence of truncation. For two patient scans with truncation, the rms error was 3.24 cm (12.2%) for PM and 4.10 cm (18.2%) for BF. The slightly better performance of PM in the case of truncation is anomalous, due to FOV edge truncation artifacts in the CT reconstruction, and thus is suspect. The calculated NCO contour for a patient SPECT/CT scan was used with an iterative reconstruction algorithm that incorporated compensation for system resolution. The resulting image was qualitatively superior to the image obtained by reconstructing the data using the fixed radius stored by the scanner. The result was also superior to the image reconstructed using the iterative algorithm provided with the system, which does not incorporate resolution modeling. These results suggest that, under conditions of no or only mild lateral truncation of the CT scan, the algorithm is capable of providing radius estimates suitable for iterative SPECT reconstruction collimator geometric resolution modeling.

  12. Local noise reduction for emphysema scoring in low-dose CT images

    NASA Astrophysics Data System (ADS)

    Schilham, Arnold; Prokop, Mathias; Gietema, Hester; van Ginneken, Bram

    2005-04-01

    Computed Tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure for emphysema derived from CT is the Pixel Index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on intensity, this measure is strongly influenced by noise. This effect shows up clearly when comparing the PI score for a high-dose scan to the PI score for a low-dose (i.e. noisy) scan of the same subject. This paper presents a class of noise filters that make use of a local noise estimate to specify the filtering strength: Local Noise Variance Weighted Averaging (LNVWA). The performance of the filter is assessed by comparing high-dose and low-dose PI scores for 11 subjects. LNVWA improves the reproducibility of high-dose PI scores: For an emphysema threshold of -910 HU, the root-mean-square difference in PI score drops from 10% of the lung volume to 3.3% of the lung volume if LNVWA is used.

  13. Rationale and Application of Tangential Scanning to Industrial Inspection of Hardwood Logs

    Treesearch

    Nand K. Gupta; Daniel L. Schmoldt; Bruce Isaacson

    1998-01-01

    Industrial computed tomography (CT) inspection of hardwood logs has some unique requirements not found in other CT applications. Sawmill operations demand that large volumes of wood be scanned quickly at high spatial resolution for extended duty cycles. Current CT scanning geometries and commercial systems have both technical and economic [imitations. Tangential...

  14. Non-Invasive Ultrasonic Diagnosing and Monitoring of Intracranial Pressure/Volume

    DTIC Science & Technology

    2001-10-01

    these risks, intracranial pressure is usually monitored only in the severely head injured patients and only if there is clinical or CT or MRI ...proportion of patients for whom the computer tomography (CT) or magnetic resonance imaging ( MRI ) scan do not show the evidence of the raised pressure...thresholds and the Cushing phenomenon induced by upper brainstem ischemia. During ICH it was demonstrated that there is an increase of sympathetic

  15. Palonosetron versus other 5-HT₃ receptor antagonists for prevention of chemotherapy-induced nausea and vomiting in patients with hematologic malignancies treated with emetogenic chemotherapy in a hospital outpatient setting in the United States.

    PubMed

    Craver, Chris; Gayle, Julie; Balu, Sanjeev; Buchner, Deborah

    2011-01-01

    This study evaluated the rate of uncontrolled chemotherapy-induced nausea and vomiting (CINV) after initiating antiemetic prophylaxis with palonosetron versus other 5-HT₃ receptor antagonists (RAs) in patients diagnosed with hematologic malignancies (lymphoma and leukemia) and receiving highly emetogenic chemotherapy (HEC) or moderately emetogenic chemotherapy (MEC) in a hospital outpatient setting. Patients aged ≥ 18 years and diagnosed with hematologic malignancies initiating HEC or MEC and antiemetic prophylaxis with palonosetron (Group 1) and other 5-HT₃ RAs (Group 2) for the first time in a hospital outpatient setting between 4/1/2007 and 3/31/2009 were identified from the Premier Perspective Database. Within each cycle, CINV events were identified (in the hospital outpatient, inpatient, and emergency room settings) through ICD-9 codes for nausea, vomiting, and/or volume depletion (from each CT administration day 1 until the end of the CT cycle), or use of rescue medications (day 2 until the end of the CT cycle). Negative binomial distribution generalized linear multivariate regression model estimating the CINV event rate on CT, specific CT cycles, and cancer diagnosis (leukemia/lymphoma)-matched groups in the follow-up period (first of 8 cycles or 6 months) was developed. Of 971 identified patients, 211 initiated palonosetron (Group 1). Group 1 patients comprised of more females [50.2 vs. 41.4%; p = 0.0226], Whites [74.4 vs. 70.4%, and Hispanics [7.6 vs. 6.3%; all races p = 0.0105], received more HEC treatments [89.6 vs. 84.2%; all CT types p = 0.0129], and had more lymphoma diagnosed patients [89.6 vs. 76.3%; all cancer types p = 0.0033] at baseline. After controlling for differences in several demographic and clinical variables, the regression model predicted a 20.4% decrease in CINV event rate per CT cycle for Group 1 versus Group 2 patients. Study limitations include potential lack of generalizability, absence of data on certain confounders including alcohol consumption and prior history of motion sickness, potential underestimation of incidence of uncontrolled CINV, and inability to draw conclusions pertaining to cause and effect relationship. In this retrospective hospital study, patients with hematologic malignancies treated with HEC or MEC and initiated on antiemetic prophylaxis with palonosetron in the hospital outpatient setting were more likely to experience significantly lower CINV event rates (in the hospital outpatient, inpatient, and emergency room settings) versus patients initiated on other 5-HT₃ RAs.

  16. Diagnostic efficacy of the Liver Imaging-Reporting and Data System (LI-RADS) with CT imaging in categorising small nodules (10-20 mm) detected in the cirrhotic liver at screening ultrasound.

    PubMed

    Abd Alkhalik Basha, M; Abd El Aziz El Sammak, D; El Sammak, A A

    2017-10-01

    To estimate the diagnostic accuracy of the Liver Imaging-Reporting and Data System (LI-RADS) with computed tomography (CT) for diagnosing hepatic nodules (10-20 mm) detected in cirrhotic livers. Fifty-five patients with liver cirrhosis and a solitary nodule (10-20 mm in diameter) detected via ultrasound surveillance, underwent hepatic CT and fine-needle biopsy. All the CT images were analysed and the lesions were categorised into five categories according to the LI-RADS. Final diagnoses of the 55 nodules were as follows: 34 hepatocellular carcinomas (HCCs), one intrahepatic cholangiocarcinomas, one adrenocortical carcinoma metastasis, and 19 benign lesions. None (0%) of four LI-RADS category 1 lesions, two (22%) of nine category 2 lesions, seven (50%) of 14 category 3 lesions, two (67%) of three category 4 lesions, 22 (96%) of 23 category 5 lesions and one (50%) of two lesions classified as other malignancies was HCC. One category 5 lesion was adrenocortical carcinoma metastasis and one of two lesions categorised as other malignancies was intrahepatic cholangiocarcinoma. In patients with nodules detected at surveillance ultrasound, the best threshold for confident HCC diagnosis was more than LI-RADS category 3. The use of this threshold produced a sensitivity and specificity of 72.7% and 90%, respectively. So combining LI-RADS 4 and 5 categories for confident HCC diagnosis would improve accuracy and sensitivity with no significant impairment of specificity or positive predictive value. LIRADS with CT provides a strong validity for the diagnosis of small hepatic nodules, and is very useful to improve the accuracy of CT reports. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  17. Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study.

    PubMed

    Kawai, Tatsuya; Takeuchi, Mitsuru; Hara, Masaki; Ohashi, Kazuya; Suzuki, Hirochika; Yamada, Kiyotaka; Sugimura, Yuya; Shibamoto, Yuta

    2013-10-01

    The effects of a tin filter on virtual non-enhanced (VNE) images created by dual-energy CT have not been well evaluated. To compare the accuracy of VNE images between those with and without a tin filter. Two different types of columnar phantoms made of agarose gel were evaluated. Phantom A contained various concentrations of iodine (4.5-1590 HU at 120 kVp). Phantom B consisted of a central component (0, 10, 25, and 40 mgI/cm(3)) and a surrounding component (0, 50, 100, and 200 mgI/cm(3)) with variable iodine concentration. They were scanned by dual-source CT in conventional single-energy mode and dual-energy mode with and without a tin filter. CT values on each gel at the corresponding points were measured and the accuracy of iodine removal was evaluated. On VNE images, the CT number of the gel of Phantom A fell within the range between -15 and +15 HU under 626 and 881 HU at single-energy 120 kVp with and without a tin filter, respectively. With attenuation over these thresholds, iodine concentration of gels was underestimated with the tin filter but overestimated without it. For Phantom B, the mean CT numbers on VNE images in the central gel component surrounded by the gel with iodine concentrations of 0, 50, 100, and 200 mgI/cm(3) were in the range of -19-+6 HU and 21-100 HU with and without the tin filter, respectively. Both with and without a tin filter, iodine removal was accurate under a threshold of iodine concentration. Although a surrounding structure with higher attenuation decreased the accuracy, a tin filter improved the margin of error.

  18. Analysis of free breathing motion using artifact reduced 4D CT image data

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Jan; Werner, Rene; Frenzel, Thorsten; Lu, Wei; Low, Daniel; Handels, Heinz

    2007-03-01

    The mobility of lung tumors during the respiratory cycle is a source of error in radiotherapy treatment planning. Spatiotemporal CT data sets can be used for studying the motion of lung tumors and inner organs during the breathing cycle. We present methods for the analysis of respiratory motion using 4D CT data in high temporal resolution. An optical flow based reconstruction method was used to generate artifact-reduced 4D CT data sets of lung cancer patients. The reconstructed 4D CT data sets were segmented and the respiratory motion of tumors and inner organs was analyzed. A non-linear registration algorithm is used to calculate the velocity field between consecutive time frames of the 4D data. The resulting velocity field is used to analyze trajectories of landmarks and surface points. By this technique, the maximum displacement of any surface point is calculated, and regions with large respiratory motion are marked. To describe the tumor mobility the motion of the lung tumor center in three orthogonal directions is displayed. Estimated 3D appearance probabilities visualize the movement of the tumor during the respiratory cycle in one static image. Furthermore, correlations between trajectories of the skin surface and the trajectory of the tumor center are determined and skin regions are identified which are suitable for prediction of the internal tumor motion. The results of the motion analysis indicate that the described methods are suitable to gain insight into the spatiotemporal behavior of anatomical and pathological structures during the respiratory cycle.

  19. Validation of Marek's disease diagnosis and monitoring of Marek's disease vaccines from samples collected in FTA cards.

    PubMed

    Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M

    2009-12-01

    The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P < 0.05) within Ct ratios was detected between samples collected fresh and in FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.

  20. Neurometric amplitude-modulation detection threshold in the guinea-pig ventral cochlear nucleus

    PubMed Central

    Sayles, Mark; Füllgrabe, Christian; Winter, Ian M

    2013-01-01

    Amplitude modulation (AM) is a pervasive feature of natural sounds. Neural detection and processing of modulation cues is behaviourally important across species. Although most ecologically relevant sounds are not fully modulated, physiological studies have usually concentrated on fully modulated (100% modulation depth) signals. Psychoacoustic experiments mainly operate at low modulation depths, around detection threshold (∼5% AM). We presented sinusoidal amplitude-modulated tones, systematically varying modulation depth between zero and 100%, at a range of modulation frequencies, to anaesthetised guinea-pigs while recording spikes from neurons in the ventral cochlear nucleus (VCN). The cochlear nucleus is the site of the first synapse in the central auditory system. At this locus significant signal processing occurs with respect to representation of AM signals. Spike trains were analysed in terms of the vector strength of spike synchrony to the amplitude envelope. Neurons showed either low-pass or band-pass temporal modulation transfer functions, with the proportion of band-pass responses increasing with increasing sound level. The proportion of units showing a band-pass response varies with unit type: sustained chopper (CS) > transient chopper (CT) > primary-like (PL). Spike synchrony increased with increasing modulation depth. At the lowest modulation depth (6%), significant spike synchrony was only observed near to the unit's best modulation frequency for all unit types tested. Modulation tuning therefore became sharper with decreasing modulation depth. AM detection threshold was calculated for each individual unit as a function of modulation frequency. Chopper units have significantly better AM detection thresholds than do primary-like units. AM detection threshold is significantly worse at 40 dB vs. 10 dB above pure-tone spike rate threshold. Mean modulation detection thresholds for sounds 10 dB above pure-tone spike rate threshold at best modulation frequency are (95% CI) 11.6% (10.0–13.1) for PL units, 9.8% (8.2–11.5) for CT units, and 10.8% (8.4–13.2) for CS units. The most sensitive guinea-pig VCN single unit AM detection thresholds are similar to human psychophysical performance (∼3% AM), while the mean neurometric thresholds approach whole animal behavioural performance (∼10% AM). PMID:23629508

  1. Reducing the number of CTs performed to monitor personalized dosimetry during peptide receptor radionuclide therapy (PRRT).

    PubMed

    Chicheportiche, Alexandre; Artoul, Faozi; Schwartz, Arnon; Grozinsky-Glasberg, Simona; Meirovitz, Amichay; Gross, David J; Godefroy, Jeremy

    2018-06-19

    Peptide receptor radionuclide therapy (PRRT) with [ 177 Lu]-DOTA-TATE is an effective treatment of neuroendocrine tumors (NETs). After each cycle of treatment, patient dosimetry evaluates the radiation dose to the risk organs, kidneys, and bone marrow, the most radiosensitive tissues. Absorbed doses are calculated from the radioactivity in the blood and from single photon emission computed tomography (SPECT) images corrected by computed tomography (CT) acquired after each course of treatment. The aim of this work is to assess whether the dosimetry along all treatment cycles can be calculated using a single CT. We hypothesize that the absorbed doses to the risk organs calculated with a single CT will be accurate enough to correctly manage the patients, i.e., whether or not to continue PRRT. Twenty-four patients diagnosed with metastatic NETs undergoing PRRT with [ 177 Lu]-DOTA-TATE were retrospectively included in this study. We compared radiation doses to the kidneys and bone marrow using two protocols. In the "classical" one, dosimetry is calculated based on a SPECT and a CT after each treatment cycle. In the new protocol, dosimetry is calculated based on a SPECT study after each cycle but with the first acquired CT for all cycles. The decision whether or not to stop PRRT because of unsafe absorbed dose to the risk organs would have been the same had the classical or the new protocol been used. The agreement between the cumulative doses to the kidneys and bone marrow obtained from the two protocols was excellent with Pearson's correlation coefficients r = 0.95 and r = 0.99 (P < 0.0001) and mean relative differences of 5.30 ± 6.20% and 0.48 ± 4.88%, respectively. Dosimetry calculations for a given patient can be done using a single CT registered to serial SPECTs. This new protocol reduces the need for a hybrid camera in the follow-up of patients receiving [ 177 Lu]-DOTA-TATE.

  2. Quantitative analysis of SMN1 gene and estimation of SMN1 deletion carrier frequency in Korean population based on real-time PCR.

    PubMed

    Lee, Tae-Mi; Kim, Sang-Wun; Lee, Kwang-Soo; Jin, Hyun-Seok; Koo, Soo Kyung; Jo, Inho; Kang, Seongman; Jung, Sung-Chul

    2004-12-01

    Spinal muscular atrophy (SMA) is an autosomal recessive disorder, caused by homozygous absence of the survival motor neuron gene (SMN1) in approximately 94% of patients. Since most carriers have only one SMN1 gene copy, several SMN1 quantitative analyses have been used for the SMA carrier detection. We developed a reliable quantitative real-time PCR with SYBR Green I dye and studied 13 patients with SMA and their 24 parents, as well as 326 healthy normal individuals. The copy number of the SMN1 gene was determined by the comparative threshold cycle (Ct) method and albumin was used as a reference gene. The homozygous SMN1 deletion ratio of patients was 0.00 and the hemizygous SMN1 deletion ratio of parents ranged from 0.39 to 0.59. The deltadelta Ct ratios of 7 persons among 326 normal individuals were within the carrier range, 0.41-0.57. According to these data, we estimated the carrier and disease prevalence of SMA at 1/47 and 1/8,496 in Korean population, respectively. These data indicated that there would be no much difference in disease prevalence of SMA compared with western countries. Since the prevalence of SMA is higher than other autosomal recessive disorders, the carrier detection method using real-time PCR could be a useful tool for genetic counseling.

  3. Toward computer-aided emphysema quantification on ultralow-dose CT: reproducibility of ventrodorsal gravity effect measurement and correction

    NASA Astrophysics Data System (ADS)

    Wiemker, Rafael; Opfer, Roland; Bülow, Thomas; Rogalla, Patrik; Steinberg, Amnon; Dharaiya, Ekta; Subramanyan, Krishna

    2007-03-01

    Computer aided quantification of emphysema in high resolution CT data is based on identifying low attenuation areas below clinically determined Hounsfield thresholds. However, the emphysema quantification is prone to error since a gravity effect can influence the mean attenuation of healthy lung parenchyma up to +/- 50 HU between ventral and dorsal lung areas. Comparing ultra-low-dose (7 mAs) and standard-dose (70 mAs) CT scans of each patient we show that measurement of the ventrodorsal gravity effect is patient specific but reproducible. It can be measured and corrected in an unsupervised way using robust fitting of a linear function.

  4. Allee effect in the selection for prime-numbered cycles in periodical cicadas.

    PubMed

    Tanaka, Yumi; Yoshimura, Jin; Simon, Chris; Cooley, John R; Tainaka, Kei-ichi

    2009-06-02

    Periodical cicadas are well known for their prime-numbered life cycles (17 and 13 years) and their mass periodical emergences. The origination and persistence of prime-numbered cycles are explained by the hybridization hypothesis on the basis of their lower likelihood of hybridization with other cycles. Recently, we showed by using an integer-based numerical model that prime-numbered cycles are indeed selected for among 10- to 20-year cycles. Here, we develop a real-number-based model to investigate the factors affecting the selection of prime-numbered cycles. We include an Allee effect in our model, such that a critical population size is set as an extinction threshold. We compare the real-number models with and without the Allee effect. The results show that in the presence of an Allee effect, prime-numbered life cycles are most likely to persist and to be selected under a wide range of extinction thresholds.

  5. Optical implementation of inner product neural associative memory

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang (Inventor)

    1995-01-01

    An optical implementation of an inner-product neural associative memory is realized with a first spatial light modulator for entering an initial two-dimensional N-tuple vector and for entering a thresholded output vector image after each iteration until convergence is reached, and a second spatial light modulator for entering M weighted vectors of inner-product scalars multiplied with each of the M stored vectors, where the inner-product scalars are produced by multiplication of the initial input vector in the first iterative cycle (and thresholded vectors in subsequent iterative cycles) with each of the M stored vectors, and the weighted vectors are produced by multiplication of the scalars with corresponding ones of the stored vectors. A Hughes liquid crystal light valve is used for the dual function of summing the weighted vectors and thresholding the sum vector. The thresholded vector is then entered through the first spatial light modulator for reiteration of the process cycle until convergence is reached.

  6. Spatial clustering of high load ocular Chlamydia trachomatis infection in trachoma: a cross-sectional population-based study.

    PubMed

    Last, Anna; Burr, Sarah; Alexander, Neal; Harding-Esch, Emma; Roberts, Chrissy H; Nabicassa, Meno; Cassama, Eunice Teixeira da Silva; Mabey, David; Holland, Martin; Bailey, Robin

    2017-07-31

    Chlamydia trachomatis (Ct) is the most common cause of bacterial sexually transmitted infection and infectious cause of blindness (trachoma) worldwide. Understanding the spatial distribution of Ct infection may enable us to identify populations at risk and improve our understanding of Ct transmission. In this study, we sought to investigate the spatial distribution of Ct infection and the clinical features associated with high Ct load in trachoma-endemic communities on the Bijagós Archipelago (Guinea Bissau). We collected 1507 conjunctival samples and corresponding detailed clinical data during a cross-sectional population-based geospatially representative trachoma survey. We used droplet digital PCR to estimate Ct load on conjunctival swabs. Geostatistical tools were used to investigate clustering of ocular Ct infections. Spatial clusters (independent of age and gender) of individuals with high Ct loads were identified using local indicators of spatial association. We did not detect clustering of individuals with low load infections. These data suggest that infections with high bacterial load may be important in Ct transmission. These geospatial tools may be useful in the study of ocular Ct transmission dynamics and as part of trachoma surveillance post-treatment, to identify clusters of infection and thresholds of Ct load that may be important foci of re-emergent infection in communities. © FEMS 2017.

  7. Results of a pilot study using self-collected mid-turbinate nasal swabs for detection of influenza virus infection among pregnant women.

    PubMed

    Thompson, Mark G; Ferber, Jeannette R; Odouli, Roxana; David, Donna; Shifflett, Pat; Meece, Jennifer K; Naleway, Allison L; Bozeman, Sam; Spencer, Sarah M; Fry, Alicia M; Li, De-Kun

    2015-05-01

    We evaluated the feasibility of asking pregnant women to self-collect and ship respiratory specimens. In a preliminary laboratory study, we compared the RT-PCR cycle threshold (CT) values of influenza A and B viruses incubated at 4 storage temperatures (from 4 to 35°C) for 6 time periods (8, 24, 48, 72, and 168 hours and 30 days), resulting in 24 conditions that were compared to an aliquot tested after standard freezing (-20°C) (baseline condition). In a subsequent pilot study, during January-February, 2014, we delivered respiratory specimen collection kits to 53 pregnant women with a medically attended acute respiratory illness using three delivery methods. CT values were stable after storage at temperatures <27°C for up to 72 hours for influenza A viruses and 48 hours for influenza B viruses. Of 53 women who received kits during the pilot, 89% collected and shipped nasal swabs as requested. However, 30% (14/47) of the women took over 2 days to collect and ship their specimen. The human control gene, ribonuclease P (RNase P), was detected in 100% of nasal swab specimens. However, the mean CT values for RNase P (26.5, 95% confidence interval [CI] = 26.0-27.1) and for the 8 influenza A virus positives in our pilot (32.2, 95% CI = 28.9-35.5) were significantly higher than the CTs observed in our 2010-2012 study using staff-collected nasal pharyngeal swabs (P-values < 0.01). Self-collection of respiratory specimens is a promising research method, but further research is needed to quantify the sensitivity and specificity of the approach. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  8. Comparison of Simplexa HSV 1 & 2 PCR with culture, immunofluorescence, and laboratory-developed TaqMan PCR for detection of herpes simplex virus in swab specimens.

    PubMed

    Gitman, Melissa R; Ferguson, David; Landry, Marie L

    2013-11-01

    The Simplexa HSV 1 & 2 direct PCR assay was compared with conventional cell culture, cytospin-enhanced direct fluorescent antibody (DFA), and a laboratory-developed real-time TaqMan PCR (LDT HSV PCR) using extracted nucleic acid for the detection of herpes simplex virus (HSV) in dermal, genital, mouth, ocular, and other swab samples. One hundred seventy-one swabs were tested prospectively, and 58 were positive for HSV (34 HSV-1 and 24 HSV-2). Cytospin-DFA detected 50 (86.2%), conventional cell culture 51 (87.9%), Simplexa direct 55 (94.8%), and LDT HSV PCR 57 (98.3%) of 58 true positives. Simplexa direct detected more positives than DFA and culture, but the differences were not significant (P = 0.0736 and P = 0.3711, respectively, by the McNemar test). Samples that were positive by all methods (n = 48) were strong positives (LDT cycle threshold [CT] value, 14.4 to 26.1). One strongly positive sample was falsely negative by LDT HSV PCR due to a failure of TaqMan probe binding. Three samples falsely negative by Simplexa direct had high CT values by LDT HSV PCR (LDT CT, 35.8 to 38.2). Omission of the DNA extraction step by Simplexa direct led to a drop in sensitivity compared to the sensitivity of LDT HSV PCR using extracted samples (94.8% versus 98.3%, respectively), but the difference was not significant (P = 0.6171). Simplexa HSV 1 & 2 direct PCR was the most expensive but required the least training of the assays used, had the lowest hands-on time and fastest assay time (75 min, versus 3 h by LDT HSV PCR), and provided the HSV type.

  9. Comparison of Simplexa HSV 1 & 2 PCR with Culture, Immunofluorescence, and Laboratory-Developed TaqMan PCR for Detection of Herpes Simplex Virus in Swab Specimens

    PubMed Central

    Gitman, Melissa R.; Ferguson, David

    2013-01-01

    The Simplexa HSV 1 & 2 direct PCR assay was compared with conventional cell culture, cytospin-enhanced direct fluorescent antibody (DFA), and a laboratory-developed real-time TaqMan PCR (LDT HSV PCR) using extracted nucleic acid for the detection of herpes simplex virus (HSV) in dermal, genital, mouth, ocular, and other swab samples. One hundred seventy-one swabs were tested prospectively, and 58 were positive for HSV (34 HSV-1 and 24 HSV-2). Cytospin-DFA detected 50 (86.2%), conventional cell culture 51 (87.9%), Simplexa direct 55 (94.8%), and LDT HSV PCR 57 (98.3%) of 58 true positives. Simplexa direct detected more positives than DFA and culture, but the differences were not significant (P = 0.0736 and P = 0.3711, respectively, by the McNemar test). Samples that were positive by all methods (n = 48) were strong positives (LDT cycle threshold [CT] value, 14.4 to 26.1). One strongly positive sample was falsely negative by LDT HSV PCR due to a failure of TaqMan probe binding. Three samples falsely negative by Simplexa direct had high CT values by LDT HSV PCR (LDT CT, 35.8 to 38.2). Omission of the DNA extraction step by Simplexa direct led to a drop in sensitivity compared to the sensitivity of LDT HSV PCR using extracted samples (94.8% versus 98.3%, respectively), but the difference was not significant (P = 0.6171). Simplexa HSV 1 & 2 direct PCR was the most expensive but required the least training of the assays used, had the lowest hands-on time and fastest assay time (75 min, versus 3 h by LDT HSV PCR), and provided the HSV type. PMID:24006008

  10. Block training periodization in alpine skiing: effects of 11-day HIT on VO2max and performance.

    PubMed

    Breil, Fabio A; Weber, Simone N; Koller, Stefan; Hoppeler, Hans; Vogt, Michael

    2010-08-01

    Attempting to achieve the high diversity of training goals in modern competitive alpine skiing simultaneously can be difficult and may lead to compromised overall adaptation. Therefore, we investigated the effect of block training periodization on maximal oxygen consumption (VO2max) and parameters of exercise performance in elite junior alpine skiers. Six female and 15 male athletes were assigned to high-intensity interval (IT, N = 13) or control training groups (CT, N = 8). IT performed 15 high-intensity aerobic interval (HIT) sessions in 11 days. Sessions were 4 x 4 min at 90-95% of maximal heart rate separated by 3-min recovery periods. CT continued their conventionally mixed training, containing endurance and strength sessions. Before and 7 days after training, subjects performed a ramp incremental test followed by a high-intensity time-to-exhaustion (tlim) test both on a cycle ergometer, a 90-s high-box jump test as well as countermovement (CMJ) and squat jumps (SJ) on a force plate. IT significantly improved relative VO2max by 6.0% (P < 0.01; male +7.5%, female +2.1%), relative peak power output by 5.5% (P < 0.01) and power output at ventilatory threshold 2 by 9.6% (P < 0.01). No changes occurred for these measures in CT. tlim remained unchanged in both groups. High-box jump performance was significantly improved in males of IT only (4.9%, P < 0.05). Jump peak power (CMJ -4.8%, SJ -4.1%; P < 0.01), but not height decreased in IT only. For competitive alpine skiers, block periodization of HIT offers a promising way to efficiently improve VO2max and performance. Compromised explosive jump performance might be associated with persisting muscle fatigue.

  11. Comparison of one commercial and two in-house TaqMan multiplex real-time PCR assays for detection of enteropathogenic, enterotoxigenic and enteroaggregative Escherichia coli.

    PubMed

    Hahn, Andreas; Luetgehetmann, Marc; Landt, Olfert; Schwarz, Norbert Georg; Frickmann, Hagen

    2017-11-01

    Enteropathogenic, enterotoxigenic and enteroaggregative Escherichia coli (EPEC, ETEC, EAEC) are among the most frequent causes of diarrhoea during travel or on military deployments. Cost-efficient and reliable real-time multiplex PCR (mPCR) assays are desirable for surveillance or point prevalence studies in remote and resource-limited tropical settings. We compared one commercial PCR kit and two in-house assays without using a gold standard to estimate sensitivity and specificity of each assay. Residual materials from nucleic acid extractions of stool samples from two groups with presumably different prevalences and increased likelihood of being infected or colonised by diarrhoeagenic E. coli were included in the assessment. One group comprised samples from returnees from tropical deployments, the second group was of migrants and study participants from high-endemicity settings. Each sample was assessed with all of the PCR assays. Cycle threshold (Ct) values were descriptively compared. The calculated sensitivities for the commercial test vs. the in-house tests were for EPEC 0.84 vs. 0.89 and 0.96, for ETEC 0.83 vs. 0.76 and 0.61, and for EAEC 0.69 vs. 0.54 and 0.69. False positive results were rare - specificity was 0.94 and 0.97 for two EPEC tests and 1.0 for all other tests. Most positive samples had late Ct values corresponding to low quantities of pathogens. Discordant test results were associated with late Ct values. As commercial and in-house assays showed comparable results, in-house tests can be assumed to be safe while affording considerable savings, making them a valuable alternative for surveillance testing in resource-limited tropical areas. © 2017 John Wiley & Sons Ltd.

  12. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    PubMed

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Comparative Evaluation of Three Homogenization Methods for Isolating Middle East Respiratory Syndrome Coronavirus Nucleic Acids From Sputum Samples for Real-Time Reverse Transcription PCR.

    PubMed

    Sung, Heungsup; Yong, Dongeun; Ki, Chang Seok; Kim, Jae Seok; Seong, Moon Woo; Lee, Hyukmin; Kim, Mi Na

    2016-09-01

    Real-time reverse transcription PCR (rRT-PCR) of sputum samples is commonly used to diagnose Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Owing to the difficulty of extracting RNA from sputum containing mucus, sputum homogenization is desirable prior to nucleic acid isolation. We determined optimal homogenization methods for isolating viral nucleic acids from sputum. We evaluated the following three sputum-homogenization methods: proteinase K and DNase I (PK-DNase) treatment, phosphate-buffered saline (PBS) treatment, and N-acetyl-L-cysteine and sodium citrate (NALC) treatment. Sputum samples were spiked with inactivated MERS-CoV culture isolates. RNA was extracted from pretreated, spiked samples using the easyMAG system (bioMérieux, France). Extracted RNAs were then subjected to rRT-PCR for MERS-CoV diagnosis (DiaPlex Q MERS-coronavirus, SolGent, Korea). While analyzing 15 spiked sputum samples prepared in technical duplicate, false-negative results were obtained with five (16.7%) and four samples (13.3%), respectively, by using the PBS and NALC methods. The range of threshold cycle (Ct) values observed when detecting upE in sputum samples was 31.1-35.4 with the PK-DNase method, 34.7-39.0 with the PBS method, and 33.9-38.6 with the NALC method. Compared with the control, which were prepared by adding a one-tenth volume of 1:1,000 diluted viral culture to PBS solution, the ranges of Ct values obtained by the PBS and NALC methods differed significantly from the mean control Ct of 33.2 (both P<0.0001). The PK-DNase method is suitable for homogenizing sputum samples prior to RNA extraction.

  14. Comparative Evaluation of Three Homogenization Methods for Isolating Middle East Respiratory Syndrome Coronavirus Nucleic Acids From Sputum Samples for Real-Time Reverse Transcription PCR

    PubMed Central

    Yong, Dongeun; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Lee, Hyukmin

    2016-01-01

    Background Real-time reverse transcription PCR (rRT-PCR) of sputum samples is commonly used to diagnose Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Owing to the difficulty of extracting RNA from sputum containing mucus, sputum homogenization is desirable prior to nucleic acid isolation. We determined optimal homogenization methods for isolating viral nucleic acids from sputum. Methods We evaluated the following three sputum-homogenization methods: proteinase K and DNase I (PK-DNase) treatment, phosphate-buffered saline (PBS) treatment, and N-acetyl-L-cysteine and sodium citrate (NALC) treatment. Sputum samples were spiked with inactivated MERS-CoV culture isolates. RNA was extracted from pretreated, spiked samples using the easyMAG system (bioMérieux, France). Extracted RNAs were then subjected to rRT-PCR for MERS-CoV diagnosis (DiaPlex Q MERS-coronavirus, SolGent, Korea). Results While analyzing 15 spiked sputum samples prepared in technical duplicate, false-negative results were obtained with five (16.7%) and four samples (13.3%), respectively, by using the PBS and NALC methods. The range of threshold cycle (Ct) values observed when detecting upE in sputum samples was 31.1–35.4 with the PK-DNase method, 34.7–39.0 with the PBS method, and 33.9–38.6 with the NALC method. Compared with the control, which were prepared by adding a one-tenth volume of 1:1,000 diluted viral culture to PBS solution, the ranges of Ct values obtained by the PBS and NALC methods differed significantly from the mean control Ct of 33.2 (both P<0.0001). Conclusions The PK-DNase method is suitable for homogenizing sputum samples prior to RNA extraction. PMID:27374711

  15. Lessons from a large norovirus outbreak: impact of viral load, patient age and ward design on duration of symptoms and shedding and likelihood of transmission.

    PubMed

    Partridge, D G; Evans, C M; Raza, M; Kudesia, G; Parsons, H K

    2012-05-01

    Hospital norovirus outbreaks cause significant financial and operational disruption which should be minimised by optimal handling of affected areas and use of isolation facilities. To identify factors associated with increased duration of symptoms and viral excretion and increased probability of transmission. Retrospective observational study of a large norovirus outbreak at a UK teaching hospital in the winter of 2009-2010 where patients were diagnosed using a real-time polymerase chain reaction (PCR) assay. Symptom duration was significantly associated with patient age (Spearman rank correlation coefficient: 0.197; P = 0.002) but not with PCR cycle threshold (C(T)) value. Duration of viral excretion was found to be longer in patients with higher viral loads. Transmission within a ward bay was not significantly associated either with age or with C(T) value but was more likely to occur in some ward blocks than others, which may relate to differences in ward design. Transfer of patients into isolation rooms or cohorted area within two days of symptom onset did not significantly influence probability of onward transmission (52% vs 47%; P = 0.67). The presented data suggest that C(T) value may guide timing of repeat sample collection if ongoing gastrointestinal symptoms may relate to other pathologies, and that patients developing symptoms of norovirus may remain in their current bay rather than being moved into isolation facilities. The bay or ward should be closed to new admissions but it should be anticipated that duration of symptoms and therefore closure will be longer when the outbreak involves elderly patients. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Virus detection by PCR following vaccination of naive calves with intranasal or injectable multivalent modified-live viral vaccines.

    PubMed

    Walz, Paul H; Newcomer, Benjamin W; Riddell, Kay P; Scruggs, Daniel W; Cortese, Victor S

    2017-09-01

    We evaluated duration of PCR-positive results following administration of modified-live viral (MLV) vaccines to beef calves. Twenty beef calves were randomly assigned to either group 1 and vaccinated intranasally with a MLV vaccine containing bovine alphaherpesvirus 1 (BoHV-1), bovine respiratory syncytial virus (BRSV), and bovine parainfluenza virus 3 (BPIV-3), or to group 2 and vaccinated subcutaneously with a MLV vaccine containing bovine viral diarrhea virus 1 and 2 (BVDV-1, -2), BoHV-1, BRSV, and BPIV-3. Deep nasopharyngeal swabs (NPS) and transtracheal washes (TTW) were collected from all calves, and whole blood was collected from group 2 calves and tested by PCR. In group 1, the proportions of calves that tested PCR-positive to BVDV, BoHV-1, BRSV, and BPIV-3 on any sample at any time were 0%, 100%, 100%, and 10%, respectively. In group 1 calves, 100% of calves became PCR-positive for BoHV-1 by day 3 post-vaccination and 100% of calves became PCR-positive for BRSV by day 7 post-vaccination. In group 2, the proportions of calves that tested positive to BVDV, BoHV-1, BRSV, and BPIV-3 on any sample at any time were 50%, 40%, 10%, and 0%, respectively. All threshold cycle (Ct) values were >30 in group 2 calves, irrespective of virus; however, Ct values <25 were observed in group 1 calves from PCR-positive results for BoHV-1 and BRSV. All calves were PCR-negative for all viruses after day 28. Following intranasal MLV viral vaccination, PCR results and Ct values for BRSV and BoHV-1 suggest that attempts to differentiate vaccine virus from natural infection is unreliable.

  17. Imaging Characteristics of Pathologically Proven Thymic Hyperplasia: Identifying Features That Can Differentiate True From Lymphoid Hyperplasia

    PubMed Central

    Araki, Tetsuro; Sholl, Lynette M.; Gerbaudo, Victor H.; Hatabu, Hiroto; Nishino, Mizuki

    2014-01-01

    OBJECTIVE The purpose of this article is to investigate the imaging characteristics of pathologically proven thymic hyperplasia and to identify features that can differentiate true hyperplasia from lymphoid hyperplasia. MATERIALS AND METHODS Thirty-one patients (nine men and 22 women; age range, 20–68 years) with pathologically confirmed thymic hyperplasia (18 true and 13 lymphoid) who underwent preoperative CT (n = 27), PET/CT (n = 5), or MRI (n = 6) were studied. The length and thickness of each thymic lobe and the transverse and anterior-posterior diameters and attenuation of the thymus were measured on CT. Thymic morphologic features and heterogeneity on CT and chemical shift on MRI were evaluated. Maximum standardized uptake values were measured on PET. Imaging features between true and lymphoid hyperplasia were compared. RESULTS No significant differences were observed between true and lymphoid hyperplasia in terms of thymic length, thickness, diameters, morphologic features, and other qualitative features (p > 0.16). The length, thickness, and diameters of thymic hyperplasia were significantly larger than the mean values of normal glands in the corresponding age group (p < 0.001). CT attenuation of lymphoid hyperplasia was significantly higher than that of true hyperplasia among 15 patients with contrast-enhanced CT (median, 47.9 vs 31.4 HU; Wilcoxon p = 0.03). The receiver operating characteristic analysis yielded greater than 41.2 HU as the optimal threshold for differentiating lymphoid hyperplasia from true hyperplasia, with 83% sensitivity and 89% specificity. A decrease of signal intensity on opposed-phase images was present in all four cases with in- and opposed-phase imaging. The mean maximum standardized uptake value was 2.66. CONCLUSION CT attenuation of the thymus was significantly higher in lymphoid hyperplasia than in true hyperplasia, with an optimal threshold of greater than 41.2 HU in this cohort of patients with pathologically confirmed thymic hyperplasia. PMID:24555583

  18. Assessment of body fat based on potential function clustering segmentation of computed tomography images

    NASA Astrophysics Data System (ADS)

    Zhang, Lixin; Lin, Min; Wan, Baikun; Zhou, Yu; Wang, Yizhong

    2005-01-01

    In this paper, a new method of body fat and its distribution testing is proposed based on CT image processing. As it is more sensitive to slight differences in attenuation than standard radiography, CT depicts the soft tissues with better clarity. And body fat has a distinct grayness range compared with its neighboring tissues in a CT image. An effective multi-thresholds image segmentation method based on potential function clustering is used to deal with multiple peaks in the grayness histogram of a CT image. The CT images of abdomens of 14 volunteers with different fatness are processed with the proposed method. Not only can the result of total fat area be got, but also the differentiation of subcutaneous fat from intra-abdominal fat has been identified. The results show the adaptability and stability of the proposed method, which will be a useful tool for diagnosing obesity.

  19. Automatic anatomy recognition on CT images with pathology

    NASA Astrophysics Data System (ADS)

    Huang, Lidong; Udupa, Jayaram K.; Tong, Yubing; Odhner, Dewey; Torigian, Drew A.

    2016-03-01

    Body-wide anatomy recognition on CT images with pathology becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem because various diseases result in various abnormalities of objects such as shape and intensity patterns. We previously developed an automatic anatomy recognition (AAR) system [1] whose applicability was demonstrated on near normal diagnostic CT images in different body regions on 35 organs. The aim of this paper is to investigate strategies for adapting the previous AAR system to diagnostic CT images of patients with various pathologies as a first step toward automated body-wide disease quantification. The AAR approach consists of three main steps - model building, object recognition, and object delineation. In this paper, within the broader AAR framework, we describe a new strategy for object recognition to handle abnormal images. In the model building stage an optimal threshold interval is learned from near-normal training images for each object. This threshold is optimally tuned to the pathological manifestation of the object in the test image. Recognition is performed following a hierarchical representation of the objects. Experimental results for the abdominal body region based on 50 near-normal images used for model building and 20 abnormal images used for object recognition show that object localization accuracy within 2 voxels for liver and spleen and 3 voxels for kidney can be achieved with the new strategy.

  20. Estimation of the tumor size at cure threshold among aggressive non-small cell lung cancers (NSCLCs): evidence from the surveillance, epidemiology, and end results (SEER) program and the national lung screening trial (NLST).

    PubMed

    Goldwasser, Deborah L

    2017-03-15

    The National Lung Screening Trial (NLST) demonstrated that non-small cell lung cancer (NSCLC) mortality can be reduced by a program of annual CT screening in high-risk individuals. However, CT screening regimens and adherence vary, potentially impacting the lung cancer mortality benefit. We defined the NSCLC cure threshold as the maximum tumor size at which a given NSCLC would be curable due to early detection. We obtained data from 518,234 NSCLCs documented in the U.S. SEER cancer registry between 1988 and 2012 and 1769 NSCLCs detected in the NLST. We demonstrated mathematically that the distribution function governing the cure threshold for the most aggressive NSCLCs, G(x|Φ = 1), was embedded in the probability function governing detection of SEER-documented NSCLCs. We determined the resulting probability functions governing detection over a range of G(x|Φ = 1) scenarios and compared them with their expected functional forms. We constructed a simulation framework to determine the cure threshold models most consistent with tumor sizes and outcomes documented in SEER and the NLST. Whereas the median tumor size for lethal NSCLCs documented in SEER is 43 mm (males) and 40 mm (females), a simulation model in which the median cure threshold for the most aggressive NSCLCs is 10 mm (males) and 15 mm (females) best fit the SEER and NLST data. The majority of NSCLCs in the NLST were treated at sizes greater than our median cure threshold estimates. New technology is needed to better distinguish and treat the most aggressive NSCLCs when they are small (i.e., 5-15 mm). © 2016 UICC.

  1. Automated segmentation of the lungs from high resolution CT images for quantitative study of chronic obstructive pulmonary diseases

    NASA Astrophysics Data System (ADS)

    Garg, Ishita; Karwoski, Ronald A.; Camp, Jon J.; Bartholmai, Brian J.; Robb, Richard A.

    2005-04-01

    Chronic obstructive pulmonary diseases (COPD) are debilitating conditions of the lung and are the fourth leading cause of death in the United States. Early diagnosis is critical for timely intervention and effective treatment. The ability to quantify particular imaging features of specific pathology and accurately assess progression or response to treatment with current imaging tools is relatively poor. The goal of this project was to develop automated segmentation techniques that would be clinically useful as computer assisted diagnostic tools for COPD. The lungs were segmented using an optimized segmentation threshold and the trachea was segmented using a fixed threshold characteristic of air. The segmented images were smoothed by a morphological close operation using spherical elements of different sizes. The results were compared to other segmentation approaches using an optimized threshold to segment the trachea. Comparison of the segmentation results from 10 datasets showed that the method of trachea segmentation using a fixed air threshold followed by morphological closing with spherical element of size 23x23x5 yielded the best results. Inclusion of greater number of pulmonary vessels in the lung volume is important for the development of computer assisted diagnostic tools because the physiological changes of COPD can result in quantifiable anatomic changes in pulmonary vessels. Using a fixed threshold to segment the trachea removed airways from the lungs to a better extent as compared to using an optimized threshold. Preliminary measurements gathered from patient"s CT scans suggest that segmented images can be used for accurate analysis of total lung volume and volumes of regional lung parenchyma. Additionally, reproducible segmentation allows for quantification of specific pathologic features, such as lower intensity pixels, which are characteristic of abnormal air spaces in diseases like emphysema.

  2. Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral CT by Direct Usage of the X-ray Tube Spectrum

    NASA Astrophysics Data System (ADS)

    Liu, Xuejin; Chen, Han; Bornefalk, Hans; Danielsson, Mats; Karlsson, Staffan; Persson, Mats; Xu, Cheng; Huber, Ben

    2015-02-01

    The variation among energy thresholds in a multibin detector for photon-counting spectral CT can lead to ring artefacts in the reconstructed images. Calibration of the energy thresholds can be used to achieve homogeneous threshold settings or to develop compensation methods to reduce the artefacts. We have developed an energy-calibration method for the different comparator thresholds employed in a photon-counting silicon-strip detector. In our case, this corresponds to specifying the linear relation between the threshold positions in units of mV and the actual deposited photon energies in units of keV. This relation is determined by gain and offset values that differ for different detector channels due to variations in the manufacturing process. Typically, the calibration is accomplished by correlating the peak positions of obtained pulse-height spectra to known photon energies, e.g. with the aid of mono-energetic x rays from synchrotron radiation, radioactive isotopes or fluorescence materials. Instead of mono-energetic x rays, the calibration method presented in this paper makes use of a broad x-ray spectrum provided by commercial x-ray tubes. Gain and offset as the calibration parameters are obtained by a regression analysis that adjusts a simulated spectrum of deposited energies to a measured pulse-height spectrum. Besides the basic photon interactions such as Rayleigh scattering, Compton scattering and photo-electric absorption, the simulation takes into account the effect of pulse pileup, charge sharing and the electronic noise of the detector channels. We verify the method for different detector channels with the aid of a table-top setup, where we find the uncertainty of the keV-value of a calibrated threshold to be between 0.1 and 0.2 keV.

  3. Some novel insights on HPV16 related cervical cancer pathogenesis based on analyses of LCR methylation, viral load, E7 and E2/E4 expressions.

    PubMed

    Das Ghosh, Damayanti; Bhattacharjee, Bornali; Sen, Shrinka; Premi, Laikangbam; Mukhopadhyay, Indranil; Chowdhury, Rahul Roy; Roy, Sudipta; Sengupta, Sharmila

    2012-01-01

    This study was undertaken to decipher the interdependent roles of (i) methylation within E2 binding site I and II (E2BS-I/II) and replication origin (nt 7862) in the long control region (LCR), (ii) expression of viral oncogene E7, (iii) expression of the transcript (E7-E1/E4) that encodes E2 repressor protein and (iv) viral load, in human papillomavirus 16 (HPV16) related cervical cancer (CaCx) pathogenesis. The results revealed over-representation (p<0.001) of methylation at nucleotide 58 of E2BS-I among E2-intact CaCx cases compared to E2-disrupted cases. Bisulphite sequencing of LCR revealed overrepresentation of methylation at nucleotide 58 or other CpGs in E2BS-I/II, among E2-intact cases than E2-disrupted cases and lack of methylation at replication origin in case of both. The viral transcript (E7-E1/E4) that produces the repressor E2 was analyzed by APOT (amplification of papillomavirus oncogenic transcript)-coupled-quantitative-RT-PCR (of E7 and E4 genes) to distinguish episomal (pure or concomitant with integrated) from purely integrated viral genomes based on the ratio, E7 C(T)/E4 C(T). Relative quantification based on comparative C(T) (threshold cycle) method revealed 75.087 folds higher E7 mRNA expression in episomal cases over purely integrated cases. Viral load and E2 gene copy numbers were negatively correlated with E7 C(T) (p = 0.007) and E2 C(T) (p<0.0001), respectively, each normalized with ACTB C(T), among episomal cases only. The k-means clustering analysis considering E7 C(T) from APOT-coupled-quantitative-RT-PCR assay, in conjunction with viral load, revealed immense heterogeneity among the HPV16 positive CaCx cases portraying integrated viral genomes. The findings provide novel insights into HPV16 related CaCx pathogenesis and highlight that CaCx cases that harbour episomal HPV16 genomes with intact E2 are likely to be distinct biologically, from the purely integrated viral genomes in terms of host genes and/or pathways involved in cervical carcinogenesis.

  4. Quantitative assessment of smoking-induced emphysema progression in longitudinal CT screening for lung cancer

    NASA Astrophysics Data System (ADS)

    Suzuki, H.; Mizuguchi, R.; Matsuhiro, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.; Moriyama, N.

    2015-03-01

    Computed tomography has been used for assessing structural abnormalities associated with emphysema. It is important to develop a robust CT based imaging biomarker that would allow quantification of emphysema progression in early stage. This paper presents effect of smoking on emphysema progression using annual changes of low attenuation volume (LAV) by each lung lobe acquired from low-dose CT images in longitudinal screening for lung cancer. The percentage of LAV (LAV%) was measured after applying CT value threshold method and small noise reduction. Progression of emphysema was assessed by statistical analysis of the annual changes represented by linear regression of LAV%. This method was applied to 215 participants in lung cancer CT screening for five years (18 nonsmokers, 85 past smokers, and 112 current smokers). The results showed that LAV% is useful to classify current smokers with rapid progression of emphysema (0.2%/year, p<0.05). This paper demonstrates effectiveness of the proposed method in diagnosis and prognosis of early emphysema in CT screening for lung cancer.

  5. Algorithm of pulmonary emphysema extraction using thoracic 3-D CT images

    NASA Astrophysics Data System (ADS)

    Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Ohmatsu, Hironobu; Tominaga, Keigo; Eguchi, Kenji; Moriyama, Noriyuki

    2008-03-01

    Emphysema patients have the tendency to increase due to aging and smoking. Emphysematous disease destroys alveolus and to repair is impossible, thus early detection is essential. CT value of lung tissue decreases due to the destruction of lung structure. This CT value becomes lower than the normal lung- low density absorption region or referred to as Low Attenuation Area (LAA). So far, the conventional way of extracting LAA by simple thresholding has been proposed. However, the CT value of CT image fluctuates due to the measurement conditions, with various bias components such as inspiration, expiration and congestion. It is therefore necessary to consider these bias components in the extraction of LAA. We removed these bias components and we proposed LAA extraction algorithm. This algorithm has been applied to the phantom image. Then, by using the low dose CT(normal: 30 cases, obstructive lung disease: 26 cases), we extracted early stage LAA and quantitatively analyzed lung lobes using lung structure.

  6. An exploratory study of volumetric analysis for assessing tumor response with (18)F-FAZA PET/CT in patients with advanced non-small-cell lung cancer (NSCLC).

    PubMed

    Kerner, Gerald S M A; Bollineni, Vikram R; Hiltermann, Thijo J N; Sijtsema, Nanna M; Fischer, Alexander; Bongaerts, Alphons H H; Pruim, Jan; Groen, Harry J M

    2016-12-01

    Hypoxia is associated with resistance to chemotherapy and radiotherapy and is randomly distributed within malignancies. Characterization of changes in intratumoral hypoxic regions is possible with specially developed PET tracers such as (18)F-fluoroazomycin arabinoside ((18)F-FAZA) while tumor metabolism can be measured with 2-deoxy-2-[(18)F]fluoro-D-glucose ((18)F-FDG). The purpose of this study was to study the effects of chemotherapy on (18)F-FAZA and (18)F-FDG uptake simultaneously in non-small-cell lung cancer (NSCLC) patients At baseline and after the second chemotherapy cycle, both PET/CT with (18)F-FDG and (18)F-FAZA was performed in seven patients with metastasized NSCLC. (18)F-FAZA and (18)F-FDG scans were aligned with deformable image registration using Mirada DBx. The primary tumors were contoured, and on the (18)F-FDG scan, volumes of interest (VOI) were drawn using a 41 % adaptive threshold technique. Subsequently, the resulting VOI was transferred to the (18)F-FAZA scan. (18)F-FAZA maximum tumor-to-background (T/Bgmax) ratio and the fractional hypoxic volume (FHV) were assessed. Measurements were corrected for partial volume effects. Finally, a voxel-by-voxel analysis of the primary tumor was performed to assess regional uptake differences. In the primary tumor of all seven patients, median (18)F-FDG standard uptake value (SUVmax) decreased significantly (p = 0.03). There was no significant decrease in (18)F-FAZA uptake as measured with T/Bgmax (p = 0.24) or the FHV (p = 0.35). Additionally, volumetric voxel-by-voxel analysis showed that low hypoxic tumors did not significantly change in hypoxic status between baseline and two cycles of chemotherapy, whereas highly hypoxic tumors did. Individualized volumetric voxel-by-voxel analysis revealed that hypoxia and metabolism were not associated before and after 2 cycles of chemotherapy. Tumor hypoxia and metabolism are independent dynamic events as measured by (18)F-FAZA PET and (18)F-FDG PET, both prior to and after treatment with chemotherapy in NSCLC patients.

  7. Microgravity validation of a novel system for RNA isolation and multiplex quantitative real time PCR analysis of gene expression on the International Space Station.

    PubMed

    Parra, Macarena; Jung, Jimmy; Boone, Travis D; Tran, Luan; Blaber, Elizabeth A; Brown, Mark; Chin, Matthew; Chinn, Tori; Cohen, Jacob; Doebler, Robert; Hoang, Dzung; Hyde, Elizabeth; Lera, Matthew; Luzod, Louie T; Mallinson, Mark; Marcu, Oana; Mohamedaly, Youssef; Ricco, Antonio J; Rubins, Kathleen; Sgarlato, Gregory D; Talavera, Rafael O; Tong, Peter; Uribe, Eddie; Williams, Jeffrey; Wu, Diana; Yousuf, Rukhsana; Richey, Charles S; Schonfeld, Julie; Almeida, Eduardo A C

    2017-01-01

    The International Space Station (ISS) National Laboratory is dedicated to studying the effects of space on life and physical systems, and to developing new science and technologies for space exploration. A key aspect of achieving these goals is to operate the ISS National Lab more like an Earth-based laboratory, conducting complex end-to-end experimentation, not limited to simple microgravity exposure. Towards that end NASA developed a novel suite of molecular biology laboratory tools, reagents, and methods, named WetLab-2, uniquely designed to operate in microgravity, and to process biological samples for real-time gene expression analysis on-orbit. This includes a novel fluidic RNA Sample Preparation Module and fluid transfer devices, all-in-one lyophilized PCR assays, centrifuge, and a real-time PCR thermal cycler. Here we describe the results from the WetLab-2 validation experiments conducted in microgravity during ISS increment 47/SPX-8. Specifically, quantitative PCR was performed on a concentration series of DNA calibration standards, and Reverse Transcriptase-quantitative PCR was conducted on RNA extracted and purified on-orbit from frozen Escherichia coli and mouse liver tissue. Cycle threshold (Ct) values and PCR efficiencies obtained on-orbit from DNA standards were similar to Earth (1 g) controls. Also, on-orbit multiplex analysis of gene expression from bacterial cells and mammalian tissue RNA samples was successfully conducted in about 3 h, with data transmitted within 2 h of experiment completion. Thermal cycling in microgravity resulted in the trapping of gas bubbles inside septa cap assay tubes, causing small but measurable increases in Ct curve noise and variability. Bubble formation was successfully suppressed in a rapid follow-up on-orbit experiment using standard caps to pressurize PCR tubes and reduce gas release during heating cycles. The WetLab-2 facility now provides a novel operational on-orbit research capability for molecular biology and demonstrates the feasibility of more complex wet bench experiments in the ISS National Lab environment.

  8. Microgravity validation of a novel system for RNA isolation and multiplex quantitative real time PCR analysis of gene expression on the International Space Station

    PubMed Central

    Boone, Travis D.; Tran, Luan; Blaber, Elizabeth A.; Brown, Mark; Chin, Matthew; Chinn, Tori; Cohen, Jacob; Doebler, Robert; Hoang, Dzung; Hyde, Elizabeth; Lera, Matthew; Luzod, Louie T.; Mallinson, Mark; Marcu, Oana; Mohamedaly, Youssef; Ricco, Antonio J.; Rubins, Kathleen; Sgarlato, Gregory D.; Talavera, Rafael O.; Tong, Peter; Uribe, Eddie; Williams, Jeffrey; Wu, Diana; Yousuf, Rukhsana; Richey, Charles S.; Schonfeld, Julie

    2017-01-01

    The International Space Station (ISS) National Laboratory is dedicated to studying the effects of space on life and physical systems, and to developing new science and technologies for space exploration. A key aspect of achieving these goals is to operate the ISS National Lab more like an Earth-based laboratory, conducting complex end-to-end experimentation, not limited to simple microgravity exposure. Towards that end NASA developed a novel suite of molecular biology laboratory tools, reagents, and methods, named WetLab-2, uniquely designed to operate in microgravity, and to process biological samples for real-time gene expression analysis on-orbit. This includes a novel fluidic RNA Sample Preparation Module and fluid transfer devices, all-in-one lyophilized PCR assays, centrifuge, and a real-time PCR thermal cycler. Here we describe the results from the WetLab-2 validation experiments conducted in microgravity during ISS increment 47/SPX-8. Specifically, quantitative PCR was performed on a concentration series of DNA calibration standards, and Reverse Transcriptase-quantitative PCR was conducted on RNA extracted and purified on-orbit from frozen Escherichia coli and mouse liver tissue. Cycle threshold (Ct) values and PCR efficiencies obtained on-orbit from DNA standards were similar to Earth (1 g) controls. Also, on-orbit multiplex analysis of gene expression from bacterial cells and mammalian tissue RNA samples was successfully conducted in about 3 h, with data transmitted within 2 h of experiment completion. Thermal cycling in microgravity resulted in the trapping of gas bubbles inside septa cap assay tubes, causing small but measurable increases in Ct curve noise and variability. Bubble formation was successfully suppressed in a rapid follow-up on-orbit experiment using standard caps to pressurize PCR tubes and reduce gas release during heating cycles. The WetLab-2 facility now provides a novel operational on-orbit research capability for molecular biology and demonstrates the feasibility of more complex wet bench experiments in the ISS National Lab environment. PMID:28877184

  9. Effect of Deep Cryogenic Treatment on Cyclic Fatigue of Endodontic Rotary Nickel Titanium Instruments

    PubMed Central

    Yazdizadeh, Mohammad; Skini, Masoumeh; Hoseini Goosheh, Seyyed Mohsen; Jafarzadeh, Mansour; Shamohammadi, Milad; Rakhshan, Vahid

    2017-01-01

    Introduction: Cyclic fatigue is the common reason for breakage of rotary instruments. This study was conducted to evaluate the effect of cryogenic treatment (CT) in improving the resistance to cyclic fatigue of endodontic rotary instruments. Methods and Materials: In this in vitro study, 20 RaCe and 20 Mtwo files were randomly divided into two groups of negative control and CT. CT files were stored in liquid nitrogen at -196°C for 24 h, and then were gradually warmed to the room temperature. All files were used (at torques and speeds recommended by their manufacturers) in a simulated canal with a 45° curvature until breakage. The time to fail (TF) was recorded and used to calculate the number of cycle to fail (NCF). Groups were compared using independent-samples t-test. Results: Mean NCFs were 1248.2±68.1, 1281.6±78.6, 4126.0±179.2, and 4175.4±190.1 cycles, for the Mtwo-control, Mtwo-CT, RaCe-control, and RaCe-CT, respectively. The difference between the controls and their respective CT groups were not significant (P>0.3). The difference between the systems was significant. Conclusion: Deep CT did not improve resistance to cyclic fatigue of the evaluated rotary files. PMID:28512489

  10. Innovative qPCR using interfacial effects to enable low threshold cycle detection and inhibition relief

    PubMed Central

    Harshman, Dustin K.; Rao, Brianna M.; McLain, Jean E.; Watts, George S.; Yoon, Jeong-Yeol

    2015-01-01

    Molecular diagnostics offers quick access to information but fails to operate at a speed required for clinical decision-making. Our novel methodology, droplet-on-thermocouple silhouette real-time polymerase chain reaction (DOTS qPCR), uses interfacial effects for droplet actuation, inhibition relief, and amplification sensing. DOTS qPCR has sample-to-answer times as short as 3 min 30 s. In infective endocarditis diagnosis, DOTS qPCR demonstrates reproducibility, differentiation of antibiotic susceptibility, subpicogram limit of detection, and thermocycling speeds of up to 28 s/cycle in the presence of tissue contaminants. Langmuir and Gibbs adsorption isotherms are used to describe the decreasing interfacial tension upon amplification. Moreover, a log-linear relationship with low threshold cycles is presented for real-time quantification by imaging the droplet-on-thermocouple silhouette with a smartphone. DOTS qPCR resolves several limitations of commercially available real-time PCR systems, which rely on fluorescence detection, have substantially higher threshold cycles, and require expensive optical components and extensive sample preparation. Due to the advantages of low threshold cycle detection, we anticipate extending this technology to biological research applications such as single cell, single nucleus, and single DNA molecule analyses. Our work is the first demonstrated use of interfacial effects for sensing reaction progress, and it will enable point-of-care molecular diagnosis of infections. PMID:26601245

  11. 18F-FDG PET/CT Can Predict Development of Thyroiditis due to Immunotherapy for Lung Cancer.

    PubMed

    Eshghi, Naghmehossadat; Garland, Linda; Nia, Emily Saghar; Betancourt, Robert; Krupinski, Elizabeth; Kuo, Phillip H

    2018-03-29

    Objective: For patients undergoing immunotherapy with nivolumab for lung cancer, determine if increased 18 F-FDG uptake in the thyroid gland predicts development of thyroiditis with subsequent hypothyroidism. Secondarily, determine if 18 F-FDG uptake in the thyroid gland correlates with administered cycles of nivolumab. Materials and Methods: Retrospective chart review over 2 years found 18 lung cancer patients treated with nivolumab and with 18 F-FDG PET/CT scans pre- and during therapy. Standardized uptake value (SUV) mean and maximum and total lesion glycolysis (TLG) of the thyroid gland were measured. SUVs were also measured for the pituitary gland, liver and spleen. Patients obtained monthly thyroid testing. PET/CT parameters were analyzed by unpaired t-test for differences between two groups (patients who developed hypothyroidism and those who did not). Correlation between development of thyroiditis and number of cycles of nivolumab received was also tested. Results: Six of eighteen patients developed hypothyroidism. T-test comparing the two groups (patients who developed hypothyroidism and those who did not) demonstrated significant differences in SUVmean ( P = 0.04), SUV max ( P = 0.04) and TLG ( P = 0.02) of the thyroid gland. Two of four patients who developed thyroiditis and had increased 18 F-FDG uptake in the thyroid gland, had normal TSH at time of follow-up 18 F-FDG PET/CT. Patients who developed thyroiditis with subsequent hypothyroidism stayed longer on therapy (10.6 cycles) compared to patients without thyroiditis (7.6 cycles), but the trend was not statistically significant. No significant difference in PET/CT parameters was observed for pituitary gland, liver or spleen. Conclusion: 18 F-FDG PET/CT can predict the development of thyroiditis with subsequent hypothyroidism before laboratory testing. Further study is required to confirm the positive trend between thyroiditis and duration of therapy. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Acquiring 4D Thoracic CT Scans Using Ciné CT Acquisition

    NASA Astrophysics Data System (ADS)

    Low, Daniel

    One method for acquiring 4D thoracic CT scans is to use ciné acquisition. Ciné acquisition is conducted by rotating the gantry and acquiring x-ray projections while keeping the couch stationary. After a complete rotation, a single set of CT slices, the number corresponding to the number of CT detector rows, is produced. The rotation period is typically sub second so each image set corresponds to a single point in time. The ciné image acquisition is repeated for at least one breathing cycle to acquire images throughout the breathing cycle. Once the images are acquired at a single couch position, the couch is moved to the abutting position and the acquisition is repeated. Post-processing of the images sets typically resorts the sets into breathing phases, stacking images from a specific phase to produce a thoracic CT scan at that phase. Benefits of the ciné acquisition protocol include, the ability to precisely identify the phase with respect to the acquired image, the ability to resort images after reconstruction, and the ability to acquire images over arbitrarily long times and for arbitrarily many images (within dose constraints).

  13. Absolute Cerebral Blood Flow Infarction Threshold for 3-Hour Ischemia Time Determined with CT Perfusion and 18F-FFMZ-PET Imaging in a Porcine Model of Cerebral Ischemia

    PubMed Central

    Cockburn, Neil; Kovacs, Michael

    2016-01-01

    CT Perfusion (CTP) derived cerebral blood flow (CBF) thresholds have been proposed as the optimal parameter for distinguishing the infarct core prior to reperfusion. Previous threshold-derivation studies have been limited by uncertainties introduced by infarct expansion between the acute phase of stroke and follow-up imaging, or DWI lesion reversibility. In this study a model is proposed for determining infarction CBF thresholds at 3hr ischemia time by comparing contemporaneously acquired CTP derived CBF maps to 18F-FFMZ-PET imaging, with the objective of deriving a CBF threshold for infarction after 3 hours of ischemia. Endothelin-1 (ET-1) was injected into the brain of Duroc-Cross pigs (n = 11) through a burr hole in the skull. CTP images were acquired 10 and 30 minutes post ET-1 injection and then every 30 minutes for 150 minutes. 370 MBq of 18F-FFMZ was injected ~120 minutes post ET-1 injection and PET images were acquired for 25 minutes starting ~155–180 minutes post ET-1 injection. CBF maps from each CTP acquisition were co-registered and converted into a median CBF map. The median CBF map was co-registered to blood volume maps for vessel exclusion, an average CT image for grey/white matter segmentation, and 18F-FFMZ-PET images for infarct delineation. Logistic regression and ROC analysis were performed on infarcted and non-infarcted pixel CBF values for each animal that developed infarct. Six of the eleven animals developed infarction. The mean CBF value corresponding to the optimal operating point of the ROC curves for the 6 animals was 12.6 ± 2.8 mL·min-1·100g-1 for infarction after 3 hours of ischemia. The porcine ET-1 model of cerebral ischemia is easier to implement then other large animal models of stroke, and performs similarly as long as CBF is monitored using CTP to prevent reperfusion. PMID:27347877

  14. The potential advantages of (18)FDG PET/CT-based target volume delineation in radiotherapy planning of head and neck cancer.

    PubMed

    Moule, Russell N; Kayani, Irfan; Moinuddin, Syed A; Meer, Khalda; Lemon, Catherine; Goodchild, Kathleen; Saunders, Michele I

    2010-11-01

    This study investigated two fixed threshold methods to delineate the target volume using (18)FDG PET/CT before and during a course of radical radiotherapy in locally advanced squamous cell carcinoma of the head and neck. Patients were enrolled into the study between March 2006 and May 2008. (18)FDG PET/CT scans were carried out 72h prior to the start of radiotherapy and then at 10, 44 and 66Gy. Functional volumes were delineated according to the SUV Cut Off (SUVCO) (2.5, 3.0, 3.5, and 4.0bwg/ml) and percentage of the SUVmax (30%, 35%, 40%, 45%, and 50%) thresholds. The background (18)FDG uptake and the SUVmax within the volumes were also assessed. Primary and lymph node volumes for the eight patients significantly reduced with each increase in the delineation threshold (for example 2.5-3.0bwg/ml SUVCO) compared to the baseline threshold at each imaging point. There was a significant reduction in the volume (p⩽0.0001-0.01) after 36Gy compared to the 0Gy by the SUVCO method. There was a negative correlation between the SUVmax within the primary and lymph node volumes and delivered radiation dose (p⩽0.0001-0.011) but no difference in the SUV within the background reference region. The volumes delineated by the PTSUVmax method increased with the increase in the delivered radiation dose after 36Gy because the SUVmax within the region of interest used to define the edge of the volume was equal or less than the background (18)FDG uptake and the software was unable to effectively differentiate between tumour and background uptake. The changes in the target volumes delineated by the SUVCO method were less susceptible to background (18)FDG uptake compared to those delineated by the PTSUVmax and may be more helpful in radiotherapy planning. The best method and threshold have still to be determined within institutions, both nationally and internationally. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  15. Extracting alveolar structure of human lung tissue specimens based on surface skeleton representation from 3D micro-CT images

    NASA Astrophysics Data System (ADS)

    Ishimori, Hiroyuki; Kawata, Yoshiki; Niki, Noboru; Nakaya, Yoshihiro; Ohmatsu, Hironobu; Matsui, Eisuke; Fujii, Masashi; Moriyama, Noriyuki

    2007-03-01

    We have developed a Micro CT system for understanding lung function at a high resolution of the micrometer order (up to 5µm in spatial resolution). Micro CT system enables the removal specimen of lungs to be observed at micro level, has expected a big contribution for micro internal organs morphology and the image diagnosis study. In this research, we develop system to visualize lung microstructures in three dimensions from micro CT images and analyze them. They characterize in that high CT value of the noise area is, and the difficulty of only using threshold processing to extract the alveolar wall of micro CT images. Thus, we are developing a method of extracting the alveolar wall with surface thinning algorithm. In this report, we propose the method which reduces the excessive degeneracy of figure which caused by surface thinning process. And, we apply this algorithm to the micro CT image of the actual pulmonary specimen. It is shown that the extraction of the alveolus wall becomes possible in the high precision.

  16. Radioembolization with 90Y glass microspheres for hepatocellular carcinoma: significance of pretreatment 11C-acetate and 18F-FDG PET/CT and posttreatment 90Y PET/CT in individualized dose prescription.

    PubMed

    Ho, Chi Lai; Chen, Sirong; Cheung, Shing Kee; Leung, Yim Lung; Cheng, Kam Chau; Wong, Ka Nin; Wong, Yuet Hung; Leung, Thomas Wai Tong

    2018-06-11

    The aim of this study was to establish an algorithm for the prescription of 90 Y glass microsphere radioembolization ( 90 Y-GMRE) of HCC in individual patients based on the relationship between tumour dose (TD) and response validated by 90 Y PET/CT dosimetry and dual-tracer PET/CT metabolic parameters. The study group comprised 62 HCC patients prospectively recruited for 90 Y-GMRE who underwent pretreatment dual-tracer ( 11 C-acetate and 18 F-FDG) PET/CT as surrogate markers of HCC cellular differentiation. Pretreatment tumour-to-nontumour ratio on 99m Tc-MAA SPECT/CT (T/NT MAA ) was correlated with posttreatment 90 Y PET/CT T/NT 90Y after quantification validation. The TD-response relationship for HCC of different tracer groups was assessed on follow-up PET/CT 2 months after treatment. 90 Y PET/CT was accurate in the measurement of recovery of injected 90 Y activity (81.9-99.9%, median 94.8%). Pretreatment SPECT/CT T/NT MAA was strongly correlated with posttreatment 90 Y PET/CT T/NT 90Y (5.6 ± 3.2 versus 5.9 ± 3.5, T/NT 90Y 1.01 × T/NT MAA  + 0.161, r = 0.918, P < 0.05). The response rates were 72.4% (21/29), 70.6% (12/17) and 25% (4/16) for well, moderately and poorly differentiated HCC, respectively. The cut-off TD for a good response was significantly different between poorly differentiated and well/moderately differentiated HCC (262 Gy versus 152/174 Gy) with 89.2% sensitivity and 88% specificity. At a limiting tolerated liver dose of 70 Gy, the T/NT MAA thresholds for predicting a good response in poorly differentiated and well/moderately differentiated HCC were 3.5 and 2.0/2.3. Disregarding HCC cellular differentiation, the cut-off TD became 170 Gy, with lower sensitivity (70.3%) and specificity (76%). 90 Y PET/CT can provide accurate dosimetry for 90 Y-GMRE. Pretreatment T/NT MAA predicts posttreatment T/NT 90Y . The TD thresholds for a good response are tracer-dependent, with a strong correlation between HCC radiosensitivity and cellular differentiation and other PET-based parameters. These cytokinetic factors improve treatment efficacy while minimizing organ damage for the prescription of personalized 90 Y-GMRE.

  17. Segmentation of bone structures in 3D CT images based on continuous max-flow optimization

    NASA Astrophysics Data System (ADS)

    Pérez-Carrasco, J. A.; Acha-Piñero, B.; Serrano, C.

    2015-03-01

    In this paper an algorithm to carry out the automatic segmentation of bone structures in 3D CT images has been implemented. Automatic segmentation of bone structures is of special interest for radiologists and surgeons to analyze bone diseases or to plan some surgical interventions. This task is very complicated as bones usually present intensities overlapping with those of surrounding tissues. This overlapping is mainly due to the composition of bones and to the presence of some diseases such as Osteoarthritis, Osteoporosis, etc. Moreover, segmentation of bone structures is a very time-consuming task due to the 3D essence of the bones. Usually, this segmentation is implemented manually or with algorithms using simple techniques such as thresholding and thus providing bad results. In this paper gray information and 3D statistical information have been combined to be used as input to a continuous max-flow algorithm. Twenty CT images have been tested and different coefficients have been computed to assess the performance of our implementation. Dice and Sensitivity values above 0.91 and 0.97 respectively were obtained. A comparison with Level Sets and thresholding techniques has been carried out and our results outperformed them in terms of accuracy.

  18. PET/CT with (18)F-choline after radical prostatectomy in patients with PSA ≤2 ng/ml. Can PSA velocity and PSA doubling time help in patient selection?

    PubMed

    Chiaravalloti, Agostino; Di Biagio, Daniele; Tavolozza, Mario; Calabria, Ferdinando; Schillaci, Orazio

    2016-07-01

    To investigate the performance of (18)F-fluorocholine ((18)F-FCH) PET/CT in relation to the prostate-specific antigen (PSA) kinetic indexes, PSA doubling time (PSAdt) and PSA velocity (PSAve), in detecting recurrent prostate cancer (PC) in a selected population of patients treated with radical prostatectomy and with PSA ≤2 ng/ml. The study group comprised 79 patients (mean age 70 ± 7 years, range 58 - 77 years) who had been treated with radical surgery 30 to 90 months previously and with biochemical failure (defined as a measurable serum PSA level) who were evaluated with (18)F-FCH PET/CT. In order to establish the optimal threshold for PSAdt and PSAve, the diagnostic performance of PSA, PSAdt and PSAve were compared by receiver operating characteristic analysis. In the population examined, PSA (mean ± SD) was 1.37 ± 0.44 ng/ml (range 0.21 - 2 ng/ml) before PET/CT examination, PSAdt was 10.04 ± 16.67 months and PSAve was 2.75 ± 3.11 ng/ml per year. (18)F-FCH PET/CT was positive in 44 patients (55 %). PSAve and PSAdt were significantly different between patients with a positive and a negative (18)F-FCH PET/CT scan. Thresholds of 6 months for PSAdt and 1 ng/ml per year for PSAve were selected. For PSAdt ≤6 months the detection rate (DR) was 65 %, and for PSAve >1 ng/ml per year the DR was 67 %. PSA values were not significantly different between patients with a positive and a negative PET/CT scan. The results of our study suggest that (18)F-FCH PET/CT could be considered for the evaluation of patients with biochemical recurrence of PC and with low PSA levels. Fast PSA kinetics could be useful in the selection of these patients.

  19. Internal validation of the GlobalFiler™ Express PCR Amplification Kit for the direct amplification of reference DNA samples on a high-throughput automated workflow.

    PubMed

    Flores, Shahida; Sun, Jie; King, Jonathan; Budowle, Bruce

    2014-05-01

    The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Respiration-Averaged CT for Attenuation Correction of PET Images – Impact on PET Texture Features in Non-Small Cell Lung Cancer Patients

    PubMed Central

    Cheng, Nai-Ming; Fang, Yu-Hua Dean; Tsan, Din-Li

    2016-01-01

    Purpose We compared attenuation correction of PET images with helical CT (PET/HCT) and respiration-averaged CT (PET/ACT) in patients with non-small-cell lung cancer (NSCLC) with the goal of investigating the impact of respiration-averaged CT on 18F FDG PET texture parameters. Materials and Methods A total of 56 patients were enrolled. Tumors were segmented on pretreatment PET images using the adaptive threshold. Twelve different texture parameters were computed: standard uptake value (SUV) entropy, uniformity, entropy, dissimilarity, homogeneity, coarseness, busyness, contrast, complexity, grey-level nonuniformity, zone-size nonuniformity, and high grey-level large zone emphasis. Comparisons of PET/HCT and PET/ACT were performed using Wilcoxon signed-rank tests, intraclass correlation coefficients, and Bland-Altman analysis. Receiver operating characteristic (ROC) curves as well as univariate and multivariate Cox regression analyses were used to identify the parameters significantly associated with disease-specific survival (DSS). A fixed threshold at 45% of the maximum SUV (T45) was used for validation. Results SUV maximum and total lesion glycolysis (TLG) were significantly higher in PET/ACT. However, texture parameters obtained with PET/ACT and PET/HCT showed a high degree of agreement. The lowest levels of variation between the two modalities were observed for SUV entropy (9.7%) and entropy (9.8%). SUV entropy, entropy, and coarseness from both PET/ACT and PET/HCT were significantly associated with DSS. Validation analyses using T45 confirmed the usefulness of SUV entropy and entropy in both PET/HCT and PET/ACT for the prediction of DSS, but only coarseness from PET/ACT achieved the statistical significance threshold. Conclusions Our results indicate that 1) texture parameters from PET/ACT are clinically useful in the prediction of survival in NSCLC patients and 2) SUV entropy and entropy are robust to attenuation correction methods. PMID:26930211

  1. Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model.

    PubMed

    Marx, Mirko; Ehrhardt, Jan; Werner, René; Schlemmer, Heinz-Peter; Handels, Heinz

    2014-05-01

    Four-dimensional CT imaging is widely used to account for motion-related effects during radiotherapy planning of lung cancer patients. However, 4D CT often contains motion artifacts, cannot be used to measure motion variability, and leads to higher dose exposure. In this article, we propose using 4D MRI to acquire motion information for the radiotherapy planning process. From the 4D MRI images, we derive a time-continuous model of the average patient-specific respiratory motion, which is then applied to simulate 4D CT data based on a static 3D CT. The idea of the motion model is to represent the average lung motion over a respiratory cycle by cyclic B-spline curves. The model generation consists of motion field estimation in the 4D MRI data by nonlinear registration, assigning respiratory phases to the motion fields, and applying a B-spline approximation on a voxel-by-voxel basis to describe the average voxel motion over a breathing cycle. To simulate a patient-specific 4D CT based on a static CT of the patient, a multi-modal registration strategy is introduced to transfer the motion model from MRI to the static CT coordinates. Differences between model-based estimated and measured motion vectors are on average 1.39 mm for amplitude-based binning of the 4D MRI data of three patients. In addition, the MRI-to-CT registration strategy is shown to be suitable for the model transformation. The application of our 4D MRI-based motion model for simulating 4D CT images provides advantages over standard 4D CT (less motion artifacts, radiation-free). This makes it interesting for radiotherapy planning.

  2. Clinics in diagnostic imaging (7). Omental caking due to ovarian carcinoma.

    PubMed

    Helpert, C; Peh, W C; Ng, T Y

    1995-12-01

    A 52-year-old Chinese woman with previously resected ovarian carcinoma was found to have ascites and a mass in the Pouch of Douglas on follow-up examination. A large omental cake was detected on computerised tomography (CT), and subsequently confirmed during laparotomy. After completion of four cycles of chemotherapy, a near complete resolution of omental metastases was demonstrated on both CT and laparotomy. The role of CT in ovarian cancer is discussed and the CT appearances of omental tumour are described.

  3. Molecular Mechanism for Prostate Cancer Resistance to the Anti-Tumor Activity

    DTIC Science & Technology

    2005-11-01

    Furukawa, T., Kanai, N., Sunamura, M., and Horii, A. (2005) J Hum Genet 50(4), 159-167 31. Armes, J. E., Hammet , F., de Silva, M., Ciciulla, J., Ramus...Relative mRNA levels were calculated 13 from the point where each curve crossed the threshold line (Ct) using the equation : Rel. Value = 2 -[Ct...JE, Hammet F, de Silva M, et al. Candidate tumor-suppressor genes on chromosome arm 8p in early-onset and high-grade breast cancers. Oncogene 2004 Jul

  4. MO-DE-207A-12: Toward Patient-Specific 4DCT Reconstruction Using Adaptive Velocity Binning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, E.D.; Glide-Hurst, C.; Wayne State University, Detroit, MI

    2016-06-15

    Purpose: While 4DCT provides organ/tumor motion information, it often samples data over 10–20 breathing cycles. For patients presenting with compromised pulmonary function, breathing patterns can change over the acquisition time, potentially leading to tumor delineation discrepancies. This work introduces a novel adaptive velocity-modulated binning (AVB) 4DCT algorithm that modulates the reconstruction based on the respiratory waveform, yielding a patient-specific 4DCT solution. Methods: AVB was implemented in a research reconstruction configuration. After filtering the respiratory waveform, the algorithm examines neighboring data to a phase reconstruction point and the temporal gate is widened until the difference between the reconstruction point and waveformmore » exceeds a threshold value—defined as percent difference between maximum/minimum waveform amplitude. The algorithm only impacts reconstruction if the gate width exceeds a set minimum temporal width required for accurate reconstruction. A sensitivity experiment of threshold values (0.5, 1, 5, 10, and 12%) was conducted to examine the interplay between threshold, signal to noise ratio (SNR), and image sharpness for phantom and several patient 4DCT cases using ten-phase reconstructions. Individual phase reconstructions were examined. Subtraction images and regions of interest were compared to quantify changes in SNR. Results: AVB increased signal in reconstructed 4DCT slices for respiratory waveforms that met the prescribed criteria. For the end-exhale phases, where the respiratory velocity is low, patient data revealed a threshold of 0.5% demonstrated increased SNR in the AVB reconstructions. For intermediate breathing phases, threshold values were required to be >10% to notice appreciable changes in CT intensity with AVB. AVB reconstructions exhibited appreciably higher SNR and reduced noise in regions of interest that were photon deprived such as the liver. Conclusion: We demonstrated that patient-specific velocity-based 4DCT reconstruction is feasible. Image noise was reduced with AVB, suggesting potential applications for low-dose acquisitions and to improve 4DCT reconstruction for irregular breathing patients. The submitting institution holds research agreements with Philips Healthcare.« less

  5. A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, subfailure material properties, CT-thresholding, and element characteristics.

    PubMed

    Arregui-Dalmases, Carlos; Del Pozo, Eduardo; Duprey, Sonia; Lopez-Valdes, Francisco J; Lau, Anthony; Subit, Damien; Kent, Richard

    2010-06-01

    The objectives of this study were to examine the axial response of the clavicle under quasistatic compressions replicating the body boundary conditions and to quantify the sensitivity of finite element-predicted fracture in the clavicle to several parameters. Clavicles were harvested from 14 donors (age range 14-56 years). Quasistatic axial compression tests were performed using a custom rig designed to replicate in situ boundary conditions. Prior to testing, high-resolution computed tomography (CT) scans were taken of each clavicle. From those images, finite element models were constructed. Factors varied parametrically included the density used to threshold cortical bone in the CT scans, the presence of trabecular bone, the mesh density, Young's modulus, the maximum stress, and the element type (shell vs. solid, triangular vs. quadrilateral surface elements). The experiments revealed significant variability in the peak force (2.41 +/- 0.72 kN) and displacement to peak force (4.9 +/- 1.1 mm), with age (p < .05) and with some geometrical traits of the specimens. In the finite element models, the failure force and location were moderately dependent upon the Young's modulus. The fracture force was highly sensitive to the yield stress (80-110 MPa). Neither fracture location nor force was strongly dependent on mesh density as long as the element size was less than 5 x 5 mm(2). Both the fracture location and force were strongly dependent upon the threshold density used to define the thickness of the cortical shell.

  6. Effects of arc current on the life in burner rig thermal cycling of plasma sprayed ZrOsub2-Ysub2Osub3

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Mcdonald, G.

    1982-01-01

    An analysis of thermal cycle life data for four sets of eight thermal barrier coated specimens representing arc currents (plasma gun power) of 525, 600, 800, or 950 amps is presented. The ZrO2-8Y2O3/NiCrAlY plasma spray coated Rene 41 rods were thermal cycled to 1040 C in a Mach 0.3-Jet A/air burner flame. The experimental results indicate the existance of a minimum or threshold power level which coating life expectancy is less than 500 cycles. Above the threshold power level, coating life expectancy more than doubles and increases with arc current.

  7. Effects of arc current on the life in burner rig thermal cycling of plasma sprayed ZrOsub2-Ysub2Osub3

    NASA Astrophysics Data System (ADS)

    Hendricks, R. C.; McDonald, G.

    1982-02-01

    An analysis of thermal cycle life data for four sets of eight thermal barrier coated specimens representing arc currents (plasma gun power) of 525, 600, 800, or 950 amps is presented. The ZrO2-8Y2O3/NiCrAlY plasma spray coated Rene 41 rods were thermal cycled to 1040 C in a Mach 0.3-Jet A/air burner flame. The experimental results indicate the existance of a minimum or threshold power level which coating life expectancy is less than 500 cycles. Above the threshold power level, coating life expectancy more than doubles and increases with arc current.

  8. Detecting fatigue thresholds from electromyographic signals: A systematic review on approaches and methodologies.

    PubMed

    Ertl, Peter; Kruse, Annika; Tilp, Markus

    2016-10-01

    The aim of the current paper was to systematically review the relevant existing electromyographic threshold concepts within the literature. The electronic databases MEDLINE and SCOPUS were screened for papers published between January 1980 and April 2015 including the keywords: neuromuscular fatigue threshold, anaerobic threshold, electromyographic threshold, muscular fatigue, aerobic-anaerobictransition, ventilatory threshold, exercise testing, and cycle-ergometer. 32 articles were assessed with regard to their electromyographic methodologies, description of results, statistical analysis and test protocols. Only one article was of very good quality. 21 were of good quality and two articles were of very low quality. The review process revealed that: (i) there is consistent evidence of one or two non-linear increases of EMG that might reflect the additional recruitment of motor units (MU) or different fiber types during fatiguing cycle ergometer exercise, (ii) most studies reported no statistically significant difference between electromyographic and metabolic thresholds, (iii) one minute protocols with increments between 10 and 25W appear most appropriate to detect muscular threshold, (iv) threshold detection from the vastus medialis, vastus lateralis, and rectus femoris is recommended, and (v) there is a great variety in study protocols, measurement techniques, and data processing. Therefore, we recommend further research and standardization in the detection of EMGTs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Selection of Reliable Reference Genes for Gene Expression Studies of a Promising Oilseed Crop, Plukenetia volubilis, by Real-Time Quantitative PCR.

    PubMed

    Niu, Longjian; Tao, Yan-Bin; Chen, Mao-Sheng; Fu, Qiantang; Li, Chaoqiong; Dong, Yuling; Wang, Xiulan; He, Huiying; Xu, Zeng-Fu

    2015-06-03

    Real-time quantitative PCR (RT-qPCR) is a reliable and widely used method for gene expression analysis. The accuracy of the determination of a target gene expression level by RT-qPCR demands the use of appropriate reference genes to normalize the mRNA levels among different samples. However, suitable reference genes for RT-qPCR have not been identified in Sacha inchi (Plukenetia volubilis), a promising oilseed crop known for its polyunsaturated fatty acid (PUFA)-rich seeds. In this study, using RT-qPCR, twelve candidate reference genes were examined in seedlings and adult plants, during flower and seed development and for the entire growth cycle of Sacha inchi. Four statistical algorithms (delta cycle threshold (ΔCt), BestKeeper, geNorm, and NormFinder) were used to assess the expression stabilities of the candidate genes. The results showed that ubiquitin-conjugating enzyme (UCE), actin (ACT) and phospholipase A22 (PLA) were the most stable genes in Sacha inchi seedlings. For roots, stems, leaves, flowers, and seeds from adult plants, 30S ribosomal protein S13 (RPS13), cyclophilin (CYC) and elongation factor-1alpha (EF1α) were recommended as reference genes for RT-qPCR. During the development of reproductive organs, PLA, ACT and UCE were the optimal reference genes for flower development, whereas UCE, RPS13 and RNA polymerase II subunit (RPII) were optimal for seed development. Considering the entire growth cycle of Sacha inchi, UCE, ACT and EF1α were sufficient for the purpose of normalization. Our results provide useful guidelines for the selection of reliable reference genes for the normalization of RT-qPCR data for seedlings and adult plants, for reproductive organs, and for the entire growth cycle of Sacha inchi.

  10. 545 N McClurg Ct, February 2015, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    The field gamma measurements within the excavation during the excavation process did not exceed theinstrument threshold previously stated and ranged from a minimum of 5,700 cpm to a maximum of 13,500cpm unshielded.

  11. 600 N McClurg Ct, April 2012, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Field gamma measurements did not exceed the respective field instrument threshold values previously stated andranged from 3,400 to 9,500 cpm unshielded with a maximum of 4,500 cpm shielded in the bottom of theexcavation

  12. Effects of CT resolution and radiodensity threshold on the CFD evaluation of nasal airflow.

    PubMed

    Quadrio, Maurizio; Pipolo, Carlotta; Corti, Stefano; Messina, Francesco; Pesci, Chiara; Saibene, Alberto M; Zampini, Samuele; Felisati, Giovanni

    2016-03-01

    The article focuses on the robustness of a CFD-based procedure for the quantitative evaluation of the nasal airflow. CFD ability to yield robust results with respect to the unavoidable procedural and modeling inaccuracies must be demonstrated to allow this tool to become part of the clinical practice in this field. The present article specifically addresses the sensitivity of the CFD procedure to the spatial resolution of the available CT scans, as well as to the choice of the segmentation level of the CT images. We found no critical problems concerning these issues; nevertheless, the choice of the segmentation level is potentially delicate if carried out by an untrained operator.

  13. CHANGES IN THE ANAEROBIC THRESHOLD IN AN ANNUAL CYCLE OF SPORT TRAINING OF YOUNG SOCCER PLAYERS

    PubMed Central

    Andrzejewski, M.; Wieczorek, A.; Barinow-Wojewódzki, A.; Jadczak, Ł.; Adrian, S.; Pietrzak, M.; Wieczorek, S.

    2013-01-01

    The aim of the study was to assess changes in the anaerobic threshold of young soccer players in an annual training cycle. A group of highly trained 15-18 year old players of KKS Lech Poznań were tested. The tests included an annual training macrocycle, and its individual stages resulted from the time structure of the sports training. In order to assess the level of exercise capacities of the players, a field exercise test of increasing intensity was carried out on a soccer pitch. The test made it possible to determine the 4 millimolar lactate threshold (T LA 4 mmol · l-1) on the basis of the lactate concentration in blood [LA], to establish the threshold running speed and the threshold heart rate [HR]. The threshold running speed at the level of the 4 millimolar lactate threshold was established using the two-point form of the equation of a straight line. The obtained indicators of the threshold running speed allowed for precise establishment of effort intensity used in individual training in developing aerobic endurance. In order to test the significance of differences in mean values between four dates of tests, a non-parametric Friedman ANOVA test was used. The significance of differences between consecutive dates of tests was determined using a post-hoc Friedman ANOVA test. The tests showed significant differences in values of selected indicators determined at the anaerobic threshold in various stages of an annual training cycle of young soccer players. The most beneficial changes in terms of the threshold running speed were noted on the fourth date of tests, when the participants had the highest values of 4.01 m · s-1 for older juniors, and 3.80 m · s-1 for younger juniors. This may be indicative of effective application of an individualized programme of training loads and of good preparation of teams for competition in terms of players’ aerobic endurance. PMID:24744480

  14. Changes in the anaerobic threshold in an annual cycle of sport training of young soccer players.

    PubMed

    Sliwowski, R; Andrzejewski, M; Wieczorek, A; Barinow-Wojewódzki, A; Jadczak, L; Adrian, S; Pietrzak, M; Wieczorek, S

    2013-06-01

    The aim of the study was to assess changes in the anaerobic threshold of young soccer players in an annual training cycle. A group of highly trained 15-18 year old players of KKS Lech Poznań were tested. The tests included an annual training macrocycle, and its individual stages resulted from the time structure of the sports training. In order to assess the level of exercise capacities of the players, a field exercise test of increasing intensity was carried out on a soccer pitch. The test made it possible to determine the 4 millimolar lactate threshold (T LA 4 mmol · l(-1)) on the basis of the lactate concentration in blood [LA], to establish the threshold running speed and the threshold heart rate [HR]. The threshold running speed at the level of the 4 millimolar lactate threshold was established using the two-point form of the equation of a straight line. The obtained indicators of the threshold running speed allowed for precise establishment of effort intensity used in individual training in developing aerobic endurance. In order to test the significance of differences in mean values between four dates of tests, a non-parametric Friedman ANOVA test was used. The significance of differences between consecutive dates of tests was determined using a post-hoc Friedman ANOVA test. The tests showed significant differences in values of selected indicators determined at the anaerobic threshold in various stages of an annual training cycle of young soccer players. The most beneficial changes in terms of the threshold running speed were noted on the fourth date of tests, when the participants had the highest values of 4.01 m · s(-1) for older juniors, and 3.80 m · s(-1) for younger juniors. This may be indicative of effective application of an individualized programme of training loads and of good preparation of teams for competition in terms of players' aerobic endurance.

  15. Histotripsy beyond the “Intrinsic” Cavitation Threshold using Very Short Ultrasound Pulses: “Microtripsy”

    PubMed Central

    Lin, Kuang-Wei; Kim, Yohan; Maxwell, Adam D.; Wang, Tzu-Yin; Hall, Timothy L.; Xu, Zhen; Fowlkes, J. Brian; Cain, Charles A.

    2014-01-01

    Histotripsy produces tissue fractionation through dense energetic bubble clouds generated by short, high-pressure, ultrasound pulses. Conventional histotripsy treatments have used longer pulses from 3 to 10 cycles wherein the lesion-producing bubble cloud generation depends on the pressure-release scattering of very high peak positive shock fronts from previously initiated, sparsely distributed bubbles (the “shock-scattering” mechanism). In our recent work, the peak negative pressure (P−) for generation of dense bubble clouds directly by a single negative half cycle, the “intrinsic threshold,” was measured. In this paper, the dense bubble clouds and resulting lesions (in RBC phantoms and canine tissues) generated by these supra-intrinsic threshold pulses were studied. A 32-element, PZT-8, 500 kHz therapy transducer was used to generate very short (< 2 cycles) histotripsy pulses at a pulse repetition frequency (PRF) of 1 Hz and P− from 24.5 to 80.7 MPa. The results showed that the spatial extent of the histotripsy-induced lesions increased as the applied P− increased, and the sizes of these lesions corresponded well to the estimates of the focal regions above the intrinsic cavitation threshold, at least in the lower pressure regime (P− = 26–35 MPa). The average sizes for the smallest reproducible lesions were approximately 0.9 × 1.7 mm (lateral × axial), significantly smaller than the −6dB beamwidth of the transducer (1.8 × 4.0 mm). These results suggest that, using the intrinsic threshold mechanism, well-confined and microscopic lesions can be precisely generated and their spatial extent can be estimated based on the fraction of the focal region exceeding the intrinsic cavitation threshold. Since the supra-threshold portion of the negative half cycle can be precisely controlled, lesions considerably less than a wavelength are easily produced, hence the term “microtripsy.” PMID:24474132

  16. The influence of respiratory motion on CT image volume definition.

    PubMed

    Rodríguez-Romero, Ruth; Castro-Tejero, Pablo

    2014-04-01

    Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. 4DCT acquisitions provided volume and position accuracies within ± 3% and ± 2 mm for structure dimensions >2 cm, breath amplitude ≤ 15 mm, and breath period ≥ 3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath patterns of higher frequency and amplitude motion. Larger volume differences (>10%) and inconsistencies between the relative positions of objects were detected in image studies acquired without respiratory control. Increasing the 3DCT rotation period caused a higher distortion in structures without obtaining their envelope. Simulated data showed that the slice acquisition time should be at least twice the breath period to average object movement. Respiratory 4DCT images provide accurate volume and position of organs affected by breath motion detecting higher volume discrepancies as amplitude length or breath frequency are increased. For 3DCT acquisitions, a CT should be considered slow enough to include lesion envelope as long as the slice acquisition time exceeds twice the breathing period. If this requirement cannot be satisfied, a fast CT (along with breath-hold inhale and exhale CTs to estimate roughly the ITV) is recommended in order to minimize structure distortion. Even with an awareness of a patient's respiratory cycle, its coupling with 3DCT acquisition cannot be predicted since patient anatomy is not accurately known. © 2014 American Association of Physicists in Medicine.

  17. The influence of respiratory motion on CT image volume definition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodríguez-Romero, Ruth, E-mail: rrromero@salud.madrid.org; Castro-Tejero, Pablo, E-mail: pablo.castro@salud.madrid.org

    Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move knownmore » geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath patterns of higher frequency and amplitude motion. Larger volume differences (>10%) and inconsistencies between the relative positions of objects were detected in image studies acquired without respiratory control. Increasing the 3DCT rotation period caused a higher distortion in structures without obtaining their envelope. Simulated data showed that the slice acquisition time should be at least twice the breath period to average object movement. Conclusions: Respiratory 4DCT images provide accurate volume and position of organs affected by breath motion detecting higher volume discrepancies as amplitude length or breath frequency are increased. For 3DCT acquisitions, a CT should be considered slow enough to include lesion envelope as long as the slice acquisition time exceeds twice the breathing period. If this requirement cannot be satisfied, a fast CT (along with breath-hold inhale and exhale CTs to estimate roughly the ITV) is recommended in order to minimize structure distortion. Even with an awareness of a patient's respiratory cycle, its coupling with 3DCT acquisition cannot be predicted since patient anatomy is not accurately known.« less

  18. Patient-specific lean body mass can be estimated from limited-coverage computed tomography images.

    PubMed

    Devriese, Joke; Beels, Laurence; Maes, Alex; van de Wiele, Christophe; Pottel, Hans

    2018-06-01

    In PET/CT, quantitative evaluation of tumour metabolic activity is possible through standardized uptake values, usually normalized for body weight (BW) or lean body mass (LBM). Patient-specific LBM can be estimated from whole-body (WB) CT images. As most clinical indications only warrant PET/CT examinations covering head to midthigh, the aim of this study was to develop a simple and reliable method to estimate LBM from limited-coverage (LC) CT images and test its validity. Head-to-toe PET/CT examinations were retrospectively retrieved and semiautomatically segmented into tissue types based on thresholding of CT Hounsfield units. LC was obtained by omitting image slices. Image segmentation was validated on the WB CT examinations by comparing CT-estimated BW with actual BW, and LBM estimated from LC images were compared with LBM estimated from WB images. A direct method and an indirect method were developed and validated on an independent data set. Comparing LBM estimated from LC examinations with estimates from WB examinations (LBMWB) showed a significant but limited bias of 1.2 kg (direct method) and nonsignificant bias of 0.05 kg (indirect method). This study demonstrates that LBM can be estimated from LC CT images with no significant difference from LBMWB.

  19. Design and Application of a Circuit for Measuring Frequency and Duty Cycle of Stimulated Bioelectrical Signal

    NASA Astrophysics Data System (ADS)

    Tang, Li-Ming; Chang, Ben-Kang; Liu, Tie-Bing; Wu, Min; Ling, Gang

    2002-12-01

    To design a new type of circuit for measuring frequency & duty cycle of stimulated bioelectrical signal for the project of 'the map of neuron-threshold in human brain and its clinical application'. This circuit was designed according to the character of stimulated bioelectrical signals. It was tested and improved and then used in the neuron -threshold stimulator. The circuit was found to be very accurate for measuring frequency and the error for measuring duty cycle was below 0.2%. This circuit is well-designed, simple, easy to use, and can be applied in many systems.

  20. A cytotoxic protein (BF-CT1) purified from Bungarus fasciatus venom acts through apoptosis, modulation of PI3K/AKT, MAPKinase pathway and cell cycle regulation.

    PubMed

    Bhattacharya, Shamik; Das, Tanaya; Biswas, Archita; Gomes, Aparna; Gomes, Antony; Dungdung, Sandhya Rekha

    2013-11-01

    BF-CT1, a 13 kDa protein isolated from Bungarus fasciatus snake venom through CM cellulose ion exchange chromatography at 0.02 M NaCl salt gradient showed cytotoxicity in in vitro and in vivo experimental models. In in vivo Ehrlich ascites carcinoma (EAC) induced BALB/c mice model, BF-CT1 treatment reduced EAC cell count significantly through apoptotic cell death pathway as evidenced by FACS analysis, increased caspase 3, 9 activity and altered pro, antiapoptotic protein expression. BF-CT1 treatment caused cell shrinkage, chromatin condensation and induced apoptosis through increased caspase 3, caspase 9 activity, PARP cleavage and down regulation of heat shock proteins in U937 leukemic cell line. Cytosolic cytochrome C production was increased after BF-CT1 treatment upon U937 cell line. BF-CT1 treated U937 cell showed cell cycle arrest at sub G1 phase through cyclin D and CDK down regulation with up regulation of p15 and p16. It also down regulated PI3K/AKT pathway and MAPkinase pathway and promoted apoptosis and regulated cell proliferation in U937 cells. BF-CT1 prevented angiogenesis in in vitro U937 cell line through decreased VEGF and TGF-β1 production. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. MicroCT with energy-resolved photon-counting detectors

    PubMed Central

    Wang, X; Meier, D; Mikkelsen, S; Maehlum, G E; Wagenaar, D J; Tsui, BMW; Patt, B E; Frey, E C

    2011-01-01

    The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with Kabsorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences. PMID:21464527

  2. Lung vessel segmentation in CT images using graph-cuts

    NASA Astrophysics Data System (ADS)

    Zhai, Zhiwei; Staring, Marius; Stoel, Berend C.

    2016-03-01

    Accurate lung vessel segmentation is an important operation for lung CT analysis. Filters that are based on analyzing the eigenvalues of the Hessian matrix are popular for pulmonary vessel enhancement. However, due to their low response at vessel bifurcations and vessel boundaries, extracting lung vessels by thresholding the vesselness is not sufficiently accurate. Some methods turn to graph-cuts for more accurate segmentation, as it incorporates neighbourhood information. In this work, we propose a new graph-cuts cost function combining appearance and shape, where CT intensity represents appearance and vesselness from a Hessian-based filter represents shape. Due to the amount of voxels in high resolution CT scans, the memory requirement and time consumption for building a graph structure is very high. In order to make the graph representation computationally tractable, those voxels that are considered clearly background are removed from the graph nodes, using a threshold on the vesselness map. The graph structure is then established based on the remaining voxel nodes, source/sink nodes and the neighbourhood relationship of the remaining voxels. Vessels are segmented by minimizing the energy cost function with the graph-cuts optimization framework. We optimized the parameters used in the graph-cuts cost function and evaluated the proposed method with two manually labeled sub-volumes. For independent evaluation, we used 20 CT scans of the VESSEL12 challenge. The evaluation results of the sub-volume data show that the proposed method produced a more accurate vessel segmentation compared to the previous methods, with F1 score 0.76 and 0.69. In the VESSEL12 data-set, our method obtained a competitive performance with an area under the ROC curve of 0.975, especially among the binary submissions.

  3. Automatic detection of cardiovascular risk in CT attenuation correction maps in Rb-82 PET/CTs

    NASA Astrophysics Data System (ADS)

    Išgum, Ivana; de Vos, Bob D.; Wolterink, Jelmer M.; Dey, Damini; Berman, Daniel S.; Rubeaux, Mathieu; Leiner, Tim; Slomka, Piotr J.

    2016-03-01

    CT attenuation correction (CTAC) images acquired with PET/CT visualize coronary artery calcium (CAC) and enable CAC quantification. CAC scores acquired with CTAC have been suggested as a marker of cardiovascular disease (CVD). In this work, an algorithm previously developed for automatic CAC scoring in dedicated cardiac CT was applied to automatic CAC detection in CTAC. The study included 134 consecutive patients undergoing 82-Rb PET/CT. Low-dose rest CTAC scans were acquired (100 kV, 11 mAs, 1.4mm×1.4mm×3mm voxel size). An experienced observer defined the reference standard with the clinically used intensity level threshold for calcium identification (130 HU). Five scans were removed from analysis due to artifacts. The algorithm extracted potential CAC by intensity-based thresholding and 3D connected component labeling. Each candidate was described by location, size, shape and intensity features. An ensemble of extremely randomized decision trees was used to identify CAC. The data set was randomly divided into training and test sets. Automatically identified CAC was quantified using volume and Agatston scores. In 33 test scans, the system detected on average 469mm3/730mm3 (64%) of CAC with 36mm3 false positive volume per scan. The intraclass correlation coefficient for volume scores was 0.84. Each patient was assigned to one of four CVD risk categories based on the Agatston score (0-10, 11-100, 101-400, <400). The correct CVD category was assigned to 85% of patients (Cohen's linearly weighted κ0.82). Automatic detection of CVD risk based on CAC scoring in rest CTAC images is feasible. This may enable large scale studies evaluating clinical value of CAC scoring in CTAC data.

  4. MicroCT with energy-resolved photon-counting detectors.

    PubMed

    Wang, X; Meier, D; Mikkelsen, S; Maehlum, G E; Wagenaar, D J; Tsui, B M W; Patt, B E; Frey, E C

    2011-05-07

    The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with K-absorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences.

  5. Utility of the PET-CT in the evaluation of early response to treatment in the diffuse large B-cell lymphoma. Preliminary results.

    PubMed

    Cortés Romera, M; Gámez Cenzano, C; Caresia Aróztegui, A P; Martín-Comín, J; González-Barca, E; Ricart Brulles, Y; Palacios Abufón, A; Robles Barba, J; Rodríguez-Bel, L; Rossi Seoane, S; Fernández de Sevilla, A

    2012-01-01

    To assess the role of FDG-PET/CT performed after the first cycles of chemotherapy in the prediction of response to treatment in patients with diffuse large B-cell lymphoma. Twenty patients (mean age: 48 years) were included, 16 initial staging and 4 relapse. All patients underwent PET/CT at 3 times: 1) Baseline, 2) After 1-3 cycles of chemotherapy (early response assessment), and 3) End of treatment (evaluation of final response). Early PET/CT findings were correlated to the end-treatment PET/CT and follow-up. The evaluation of the response was established according to the decrease in uptake of the lesions (SUVmax). In the early assessment, a good response indicator (GRI) was obtained when the lesion disappeared or had more than 50% reduction in SUVmax. At the end of the treatment, a complete metabolic response (CMR) was determined in negative PET scans. Follow-up was superior to 19 months and final outcome was established as progression/relapse or no evidence of disease (NED). At the early treatment evaluation, 16/16 patients of initial staging (100%) and 2/4 of relapse (50%) achieved GRI. At the end of treatment evaluation, 14/16 patients of initial staging with GRI achieved CMR and 1/16 PMR: 14 were alive with NED in the follow-up while 1 relapsed. In the second group, 2/2 patients with GRI achieved CMR (100%): 1 continued with NED in the follow-up and another relapsed. FDG-PET/CT after the first cycles of chemotherapy is useful to monitor treatment due to its high negative predictive value (87.5%), using it to modify treatment early in the non-responders. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.

  6. Patient-Specific Circulating Tumor DNA Detection during Neoadjuvant Chemotherapy in Triple-Negative Breast Cancer.

    PubMed

    Riva, Francesca; Bidard, Francois-Clement; Houy, Alexandre; Saliou, Adrien; Madic, Jordan; Rampanou, Aurore; Hego, Caroline; Milder, Maud; Cottu, Paul; Sablin, Marie-Paule; Vincent-Salomon, Anne; Lantz, Olivier; Stern, Marc-Henri; Proudhon, Charlotte; Pierga, Jean-Yves

    2017-03-01

    In nonmetastatic triple-negative breast cancer (TNBC) patients, we investigated whether circulating tumor DNA (ctDNA) detection can reflect the tumor response to neoadjuvant chemotherapy (NCT) and detect minimal residual disease after surgery. Ten milliliters of plasma were collected at 4 time points: before NCT; after 1 cycle; before surgery; after surgery. Customized droplet digital PCR (ddPCR) assays were used to track tumor protein p53 ( TP53 ) mutations previously characterized in tumor tissue by massively parallel sequencing (MPS). Forty-six patients with nonmetastatic TNBC were enrolled. TP53 mutations were identified in 40 of them. Customized ddPCR probes were validated for 38 patients, with excellent correlation with MPS ( r = 0.99), specificity (≥2 droplets/assay), and sensitivity (at least 0.1%). At baseline, ctDNA was detected in 27/36 patients (75%). Its detection was associated with mitotic index ( P = 0.003), tumor grade ( P = 0.003), and stage ( P = 0.03). During treatment, we observed a drop of ctDNA levels in all patients but 1. No patient had detectable ctDNA after surgery. The patient with rising ctDNA levels experienced tumor progression during NCT. Pathological complete response (16/38 patients) was not correlated with ctDNA detection at any time point. ctDNA positivity after 1 cycle of NCT was correlated with shorter disease-free ( P < 0.001) and overall ( P = 0.006) survival. Customized ctDNA detection by ddPCR achieved a 75% detection rate at baseline. During NCT, ctDNA levels decreased quickly and minimal residual disease was not detected after surgery. However, a slow decrease of ctDNA level during NCT was strongly associated with shorter survival. © 2016 American Association for Clinical Chemistry.

  7. Determination of Anaerobic Threshold by Heart Rate or Heart Rate Variability using Discontinuous Cycle Ergometry.

    PubMed

    Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan

    The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.

  8. Transcranial direct current stimulation and cognitive training in the rehabilitation of Alzheimer disease: A case study.

    PubMed

    Penolazzi, Barbara; Bergamaschi, Susanna; Pastore, Massimiliano; Villani, Daniele; Sartori, Giuseppe; Mondini, Sara

    2015-01-01

    In the present study we tested the cognitive effects of transcranial direct current stimulation (tDCS) in a case of probable Alzheimer disease (AD). The patient (male, 60 years, mild AD) underwent two cycles of treatments, separated by 2 months. In the first cycle, active stimulation (10 sessions, 2 mA for 20 min; anode over the left dorsolateral prefrontal cortex) was followed by computerised tasks (CTs) specifically chosen to engage the most impaired cognitive processes in the patient (tDCS+CT condition). In the second cycle, which was structured as the first, CTs were administered after placebo stimulation (sham+CT condition). Effects on cognitive performance were evaluated not only by the CTs, but also by neuropsychological tests assessing global cognitive functioning. Statistical analyses revealed that whereas the tDCS+CT condition had few effects on the CTs, it induced a stability of the patient's global cognitive functioning lasting approximately 3 months, which was not achieved when the patient underwent sham+CT condition. Therefore, the synergetic use of tDCS and CTs appeared to slow down the cognitive decline of our patient. This preliminary result, although in need of further confirmation, suggests the potentiality of tDCS as an adjuvant tool for cognitive rehabilitation in AD.

  9. Classification of pulmonary emphysema from chest CT scans using integral geometry descriptors

    NASA Astrophysics Data System (ADS)

    van Rikxoort, E. M.; Goldin, J. G.; Galperin-Aizenberg, M.; Brown, M. S.

    2011-03-01

    To gain insight into the underlying pathways of emphysema and monitor the effect of treatment, methods to quantify and phenotype the different types of emphysema from chest CT scans are of crucial importance. Current standard measures rely on density thresholds for individual voxels, which is influenced by inspiration level and does not take into account the spatial relationship between voxels. Measures based on texture analysis do take the interrelation between voxels into account and therefore might be useful for distinguishing different types of emphysema. In this study, we propose to use Minkowski functionals combined with rotation invariant Gaussian features to distinguish between healthy and emphysematous tissue and classify three different types of emphysema. Minkowski functionals characterize binary images in terms of geometry and topology. In 3D, four Minkowski functionals are defined. By varying the threshold and size of neighborhood around a voxel, a set of Minkowski functionals can be defined for each voxel. Ten chest CT scans with 1810 annotated regions were used to train the method. A set of 108 features was calculated for each training sample from which 10 features were selected to be most informative. A linear discriminant classifier was trained to classify each voxel in the lungs into a subtype of emphysema or normal lung. The method was applied to an independent test set of 30 chest CT scans with varying amounts and types of emphysema with 4347 annotated regions of interest. The method is shown to perform well, with an overall accuracy of 95%.

  10. Metastatic renal cell carcinoma: CT-guided immunotherapy as a technically feasible and safe approach to delivery of gene therapy for treatment.

    PubMed

    Suh, Robert D; Goldin, Jonathan G; Wallace, Amanda B; Sheehan, Ramon E; Heinze, Stefan B; Gitlitz, Barbara J; Figlin, Robert A

    2004-05-01

    To assess the technical feasibility and safety of weekly outpatient percutaneous computed tomographic (CT)-guided intratumoral injections of interleukin-2 (IL-2) plasmid DNA in a wide variety of superficial and deep tumor sites. Twenty-nine patients with metastatic renal cell carcinoma and a total of 30 lesions measuring 1.0 cm(2) or greater in accessible thoracic (n = 15) or abdominal (n = 15) locations underwent up to three cycles of six weekly intratumoral IL-2 plasmid DNA injections. CT was used to guide needle placement and injection. After injection cycle 1, patients whose tumors demonstrated stable (< or =25% increase and < or =50% decrease in product of lesion diameters) or decreased size (>50% decrease in product of lesion diameters) advanced to injection cycle 2. Patients whose lesions decreased in size by more than 50% over the course of injection cycle 2 were eligible to begin injection cycle 3. An acceptable safety and technical feasibility profile for this technique was deemed to be (a) a safety and feasibility profile similar to that of single-needle biopsy and (b) an absence of serious adverse events (as defined in Title 21 of the Code of Federal Regulations) and/or unacceptable toxicities (as graded according to the National Cancer Institute Common Toxicity Criteria). A total of 284 intratumoral injections were performed, with a mean of 9.8 injections (range, 6-18 injections) received by each patient. Technical success (needle placement and injection of gene therapy agent) was achieved in all cases. Complications were experienced after 42 (14.8%) of the 284 injections. The most common complication was pneumothorax (at 32 [28.6%] of 112 intrathoracic injections), for which only one patient required catheter drainage. Complications occurred randomly throughout injection cycles and did not appear to increase as patients received more injections (P =.532). No patient experienced serious adverse events or unacceptable toxicities. Percutaneous CT-guided intratumoral immunotherapy injections are technically feasible and can be safely performed.

  11. Association between textural and morphological tumor indices on baseline PET-CT and early metabolic response on interim PET-CT in bulky malignant lymphomas.

    PubMed

    Ben Bouallègue, Fayçal; Tabaa, Yassine Al; Kafrouni, Marilyne; Cartron, Guillaume; Vauchot, Fabien; Mariano-Goulart, Denis

    2017-09-01

    We investigated whether metabolic, textural, and morphological tumoral indices evaluated on baseline PET-CT were predictive of early metabolic response on interim PET-CT in a cohort of patients with bulky Hodgkin and non-Hodgkin malignant lymphomas. This retrospective study included 57 patients referred for initial PET-CT examination. In-house dedicated software was used to delineate tumor contours using a fixed 30% threshold of SUV max and then to compute tumoral metabolic parameters (SUV max, mean, peak, standard deviation, skewness and kurtosis, metabolic tumoral volume (MTV), total lesion glycolysis, and area under the curve of the cumulative histogram), textural parameters (Moran's and Geary's indices, energy, entropy, contrast, correlation derived from the gray-level co-occurrence matrix, area under the curve of the power spectral density, auto-correlation distance, and granularity), and shape parameters (surface, asphericity, convexity, surfacic extension, and 2D and 3D fractal dimensions). Early metabolic response was assessed on interim PET-CT using the Deauville 5-point scale and patients were ranked according to the Lugano classification as complete or not complete metabolic responders. The impact of the segmentation method (alternate threshold at 41%) and image resolution (Gaussian postsmoothing of 3, 5, and 7 mm) was investigated. The association of the proposed parameters with early response was assessed in univariate and multivariate analyses. Their added predictive value was explored using supervised classification by support vector machines (SVM). We evaluated in leave-one-out cross-validation three SVMs admitting as input features (a) MTV, (b) MTV + histological type, and (c) MTV + histology + relevant texture/shape indices. Features associated with complete metabolic response were low MTV (P = 0.01), low TLG (P = 0.003), high power spectral density AUC (P = 0.007), high surfacic extension (P = 0.006), low 2D fractal dimension (P = 0.007), and low 3D fractal dimension (P = 0.003). The prognostic value of these metrics was optimal with the 30% segmentation threshold and overall was progressively altered with decreasing image resolution. In cross-validation, the SVM accounting for texture and shape achieved the highest predictive value with ROC AUC of 0.82 and 80% accuracy (compared with 0.68 and 61% for MTV, and 0.65 and 68% for MTV + histology). The combination of usual prognostic factors with appropriately chosen textural and shape parameters evaluated on baseline PET-CT improves the prediction of early metabolic response in bulky lymphoma. © 2017 American Association of Physicists in Medicine.

  12. Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)

    NASA Astrophysics Data System (ADS)

    McCollough, Cynthia; Zhang, Jie; Bruesewitz, Michael; Bartholmai, Brian

    2006-03-01

    To create a repository of clinical data, CT images and tissue samples and to more clearly understand the pathogenetic features of pulmonary fibrosis and emphysema, the National Heart, Lung, and Blood Institute (NHLBI) launched a cooperative effort known as the Lung Tissue Resource Consortium (LTRC). The CT images for the LTRC effort must contain accurate CT numbers in order to characterize tissues, and must have high-spatial resolution to show fine anatomic structures. This study was performed to optimize the CT image reconstruction algorithms to achieve these criteria. Quantitative analyses of phantom and clinical images were conducted. The ACR CT accreditation phantom containing five regions of distinct CT attenuations (CT numbers of approximately -1000 HU, -80 HU, 0 HU, 130 HU and 900 HU), and a high-contrast spatial resolution test pattern, was scanned using CT systems from two manufacturers (General Electric (GE) Healthcare and Siemens Medical Solutions). Phantom images were reconstructed using all relevant reconstruction algorithms. Mean CT numbers and image noise (standard deviation) were measured and compared for the five materials. Clinical high-resolution chest CT images acquired on a GE CT system for a patient with diffuse lung disease were reconstructed using BONE and STANDARD algorithms and evaluated by a thoracic radiologist in terms of image quality and disease extent. The clinical BONE images were processed with a 3 x 3 x 3 median filter to simulate a thicker slice reconstructed in smoother algorithms, which have traditionally been proven to provide an accurate estimation of emphysema extent in the lungs. Using a threshold technique, the volume of emphysema (defined as the percentage of lung voxels having a CT number lower than -950 HU) was computed for the STANDARD, BONE, and BONE filtered. The CT numbers measured in the ACR CT Phantom images were accurate for all reconstruction kernels for both manufacturers. As expected, visual evaluation of the spatial resolution bar patterns demonstrated that the BONE (GE) and B46f (Siemens) showed higher spatial resolution compared to the STANDARD (GE) or B30f (Siemens) reconstruction algorithms typically used for routine body CT imaging. Only the sharper images were deemed clinically acceptable for the evaluation of diffuse lung disease (e.g. emphysema). Quantitative analyses of the extent of emphysema in patient data showed the percent volumes above the -950 HU threshold as 9.4% for the BONE reconstruction, 5.9% for the STANDARD reconstruction, and 4.7% for the BONE filtered images. Contrary to the practice of using standard resolution CT images for the quantitation of diffuse lung disease, these data demonstrate that a single sharp reconstruction (BONE/B46f) should be used for both the qualitative and quantitative evaluation of diffuse lung disease. The sharper reconstruction images, which are required for diagnostic interpretation, provide accurate CT numbers over the range of -1000 to +900 HU and preserve the fidelity of small structures in the reconstructed images. A filtered version of the sharper images can be accurately substituted for images reconstructed with smoother kernels for comparison to previously published results.

  13. Quiescent period respiratory gating for PET∕CT

    PubMed Central

    Liu, Chi; Alessio, Adam; Pierce, Larry; Thielemans, Kris; Wollenweber, Scott; Ganin, Alexander; Kinahan, Paul

    2010-01-01

    Purpose: To minimize respiratory motion artifacts, this work proposes quiescent period gating (QPG) methods that extract PET data from the end-expiration quiescent period and form a single PET frame with reduced motion and improved signal-to-noise properties. Methods: Two QPG methods are proposed and evaluated. Histogram-based quiescent period gating (H-QPG) extracts a fraction of PET data determined by a window of the respiratory displacement signal histogram. Cycle-based quiescent period gating (C-QPG) extracts data with a respiratory displacement signal below a specified threshold of the maximum amplitude of each individual respiratory cycle. Performances of both QPG methods were compared to ungated and five-bin phase-gated images across 21 FDG-PET∕CT patient data sets containing 31 thorax and abdomen lesions as well as with computer simulations driven by 1295 different patient respiratory traces. Image quality was evaluated in terms of the lesion SUVmax and the fraction of counts included in each gate as a surrogate for image noise. Results: For all the gating methods, image noise artifactually increases SUVmax when the fraction of counts included in each gate is less than 50%. While simulation data show that H-QPG is superior to C-QPG, the H-QPG and C-QPG methods lead to similar quantification-noise tradeoffs in patient data. Compared to ungated images, both QPG methods yield significantly higher lesion SUVmax. Compared to five-bin phase gating, the QPG methods yield significantly larger fraction of counts with similar SUVmax improvement. Both QPG methods result in increased lesion SUVmax for patients whose lesions have longer quiescent periods. Conclusions: Compared to ungated and phase-gated images, the QPG methods lead to images with less motion blurring and an improved compromise between SUVmax and fraction of counts. The QPG methods for respiratory motion compensation could effectively improve tumor quantification with minimal noise increase. PMID:20964223

  14. Selection and evaluation of reference genes for expression studies with quantitative PCR in the model fungus Neurospora crassa under different environmental conditions in continuous culture.

    PubMed

    Cusick, Kathleen D; Fitzgerald, Lisa A; Pirlo, Russell K; Cockrell, Allison L; Petersen, Emily R; Biffinger, Justin C

    2014-01-01

    Neurospora crassa has served as a model organism for studying circadian pathways and more recently has gained attention in the biofuel industry due to its enhanced capacity for cellulase production. However, in order to optimize N. crassa for biotechnological applications, metabolic pathways during growth under different environmental conditions must be addressed. Reverse-transcription quantitative PCR (RT-qPCR) is a technique that provides a high-throughput platform from which to measure the expression of a large set of genes over time. The selection of a suitable reference gene is critical for gene expression studies using relative quantification, as this strategy is based on normalization of target gene expression to a reference gene whose expression is stable under the experimental conditions. This study evaluated twelve candidate reference genes for use with N. crassa when grown in continuous culture bioreactors under different light and temperature conditions. Based on combined stability values from NormFinder and Best Keeper software packages, the following are the most appropriate reference genes under conditions of: (1) light/dark cycling: btl, asl, and vma1; (2) all-dark growth: btl, tbp, vma1, and vma2; (3) temperature flux: btl, vma1, act, and asl; (4) all conditions combined: vma1, vma2, tbp, and btl. Since N. crassa exists as different cell types (uni- or multi-nucleated), expression changes in a subset of the candidate genes was further assessed using absolute quantification. A strong negative correlation was found to exist between ratio and threshold cycle (CT) values, demonstrating that CT changes serve as a reliable reflection of transcript, and not gene copy number, fluctuations. The results of this study identified genes that are appropriate for use as reference genes in RT-qPCR studies with N. crassa and demonstrated that even with the presence of different cell types, relative quantification is an acceptable method for measuring gene expression changes during growth in bioreactors.

  15. The Assessment of Estrogen Receptor Status and Its Intratumoral Heterogeneity in Patients With Breast Cancer by Using 18F-Fluoroestradiol PET/CT.

    PubMed

    Yang, Zhongyi; Sun, Yifei; Xu, Xiaoping; Zhang, Yongping; Zhang, Jianping; Xue, Jing; Wang, Mingwei; Yuan, Huiyu; Hu, Silong; Shi, Wei; Zhu, Beiling; Zhang, Yingjian

    2017-06-01

    The aim of this study was to investigate the clinical value of F-fluoroestradiol (F-FES) PET/CT in the assessment of the estrogen receptor (ER) and its intratumoral heterogeneity in breast cancer patients. Forty-six female patients (50 lesions) with histologically confirmed invasive breast cancer who underwent both F-FES and F-FDG PET/CT in our center were retrospectively included. All the patients enrolled were scheduled to undergo biopsy. The F-FES and FDG uptakes were compared with pathological features (tumor size, ER, progesterone receptor, human epidermal growth factor receptor 2, and Ki67%). The optimal threshold to discriminate ER-positive and ER-negative lesions was determined by receiver operating characteristic curve analysis. Furthermore, we observed the intratumoral heterogeneity by a heterogeneity index (SUVmax/SUVmean) and compared the results with the Chang-Gung Image Texture Analysis. There was good agreement between F-FES uptake and ER, progesterone receptor, and human epidermal growth factor receptor 2 expression (P < 0.001), and the use of SUVmean instead of SUVmax can provide a slightly better correlation. The optimal threshold for F-FES PET/CT to discriminate between ER-positive and ER-negative lesions, as determined by receiver operating characteristic curve analysis, was an SUVmax of 1.82 (sensitivity = 88.2% and specificity = 87.5%) and SUVmean of 1.21 (sensitivity = 85.3% and specificity = 93.7). Our simplified heterogeneity index-FES can easily observe ER heterogeneity. In addition, our results suggested that recurrent/metastatic patients and lesions located other than breast might have greater heterogeneity. F-FES PET/CT is a feasible, noninvasive method for assessing ER expression in breast cancer patients. Because intratumoral heterogeneity exists, F-FES PET/CT might better reflect the ER expression, especially in metastatic patients after treatment, thus assisting in making individualized treatment decisions.

  16. Gamma-ray blazar spectra with H.E.S.S. II mono analysis: The case of PKS 2155-304 and PG 1553+113

    NASA Astrophysics Data System (ADS)

    H.E.S.S. Collaboration; Abdalla, H.; Abramowski, A.; Aharonian, F.; Ait Benkhali, F.; Akhperjanian, A. G.; Andersson, T.; Angüner, E. O.; Arrieta, M.; Aubert, P.; Backes, M.; Balzer, A.; Barnard, M.; Becherini, Y.; Becker Tjus, J.; Berge, D.; Bernhard, S.; Bernlöhr, K.; Blackwell, R.; Böttcher, M.; Boisson, C.; Bolmont, J.; Bordas, P.; Brun, F.; Brun, P.; Bryan, M.; Bulik, T.; Capasso, M.; Carr, J.; Casanova, S.; Cerruti, M.; Chakraborty, N.; Chalme-Calvet, R.; Chaves, R. C. G.; Chen, A.; Chevalier, J.; Chrétien, M.; Colafrancesco, S.; Cologna, G.; Condon, B.; Conrad, J.; Couturier, C.; Cui, Y.; Davids, I. D.; Degrange, B.; Deil, C.; Devin, J.; deWilt, P.; Dirson, L.; Djannati-Ataï, A.; Domainko, W.; Donath, A.; Drury, L. O.'C.; Dubus, G.; Dutson, K.; Dyks, J.; Edwards, T.; Egberts, K.; Eger, P.; Ernenwein, J.-P.; Eschbach, S.; Farnier, C.; Fegan, S.; Fernandes, M. V.; Fiasson, A.; Fontaine, G.; Förster, A.; Funk, S.; Füßling, M.; Gabici, S.; Gajdus, M.; Gallant, Y. A.; Garrigoux, T.; Giavitto, G.; Giebels, B.; Glicenstein, J. F.; Gottschall, D.; Goyal, A.; Grondin, M.-H.; Hadasch, D.; Hahn, J.; Haupt, M.; Hawkes, J.; Heinzelmann, G.; Henri, G.; Hermann, G.; Hervet, O.; Hillert, A.; Hinton, J. A.; Hofmann, W.; Hoischen, C.; Holler, M.; Horns, D.; Ivascenko, A.; Jacholkowska, A.; Jamrozy, M.; Janiak, M.; Jankowsky, D.; Jankowsky, F.; Jingo, M.; Jogler, T.; Jouvin, L.; Jung-Richardt, I.; Kastendieck, M. A.; Katarzyński, K.; Katz, U.; Kerszberg, D.; Khélifi, B.; Kieffer, M.; King, J.; Klepser, S.; Klochkov, D.; Kluźniak, W.; Kolitzus, D.; Komin, Nu.; Kosack, K.; Krakau, S.; Kraus, M.; Krayzel, F.; Krüger, P. P.; Laffon, H.; Lamanna, G.; Lau, J.; Lees, J.-P.; Lefaucheur, J.; Lefranc, V.; Lemière, A.; Lemoine-Goumard, M.; Lenain, J.-P.; Leser, E.; Lohse, T.; Lorentz, M.; Liu, R.; López-Coto, R.; Lypova, I.; Marandon, V.; Marcowith, A.; Mariaud, C.; Marx, R.; Maurin, G.; Maxted, N.; Mayer, M.; Meintjes, P. J.; Meyer, M.; Mitchell, A. M. W.; Moderski, R.; Mohamed, M.; Mohrmann, L.; Morå, K.; Moulin, E.; Murach, T.; de Naurois, M.; Niederwanger, F.; Niemiec, J.; Oakes, L.; O'Brien, P.; Odaka, H.; Öttl, S.; Ohm, S.; Ostrowski, M.; Oya, I.; Padovani, M.; Panter, M.; Parsons, R. D.; Paz Arribas, M.; Pekeur, N. W.; Pelletier, G.; Perennes, C.; Petrucci, P.-O.; Peyaud, B.; Pita, S.; Poon, H.; Prokhorov, D.; Prokoph, H.; Pühlhofer, G.; Punch, M.; Quirrenbach, A.; Raab, S.; Reimer, A.; Reimer, O.; Renaud, M.; de los Reyes, R.; Rieger, F.; Romoli, C.; Rosier-Lees, S.; Rowell, G.; Rudak, B.; Rulten, C. B.; Sahakian, V.; Salek, D.; Sanchez, D. A.; Santangelo, A.; Sasaki, M.; Schlickeiser, R.; Schüssler, F.; Schulz, A.; Schwanke, U.; Schwemmer, S.; Settimo, M.; Seyffert, A. S.; Shafi, N.; Shilon, I.; Simoni, R.; Sol, H.; Spanier, F.; Spengler, G.; Spies, F.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Stinzing, F.; Stycz, K.; Sushch, I.; Tavernet, J.-P.; Tavernier, T.; Taylor, A. M.; Terrier, R.; Tibaldo, L.; Tiziani, D.; Tluczykont, M.; Trichard, C.; Tuffs, R.; Uchiyama, Y.; van der Walt, D. J.; van Eldik, C.; van Soelen, B.; Vasileiadis, G.; Veh, J.; Venter, C.; Viana, A.; Vincent, P.; Vink, J.; Voisin, F.; Völk, H. J.; Vuillaume, T.; Wadiasingh, Z.; Wagner, S. J.; Wagner, P.; Wagner, R. M.; White, R.; Wierzcholska, A.; Willmann, P.; Wörnlein, A.; Wouters, D.; Yang, R.; Zabalza, V.; Zaborov, D.; Zacharias, M.; Zdziarski, A. A.; Zech, A.; Zefi, F.; Ziegler, A.; Żywucka, N.; LAT Collaboration; Ackermann, M.; Ajello, M.; Baldini, L.; Barbiellini, G.; Bellazzini, R.; Blandford, R. D.; Bonino, R.; Bregeon, J.; Bruel, P.; Buehler, R.; Caliandro, G. A.; Cameron, R. A.; Caragiulo, M.; Caraveo, P. A.; Cavazzuti, E.; Cecchi, C.; Chiang, J.; Chiaro, G.; Ciprini, S.; Cohen-Tanugi, J.; Costanza, F.; Cutini, S.; D'Ammando, F.; de Palma, F.; Desiante, R.; Di Lalla, N.; Di Mauro, M.; Di Venere, L.; Donaggio, B.; Favuzzi, C.; Focke, W. B.; Fusco, P.; Gargano, F.; Gasparrini, D.; Giglietto, N.; Giordano, F.; Giroletti, M.; Guillemot, L.; Guiriec, S.; Horan, D.; Jóhannesson, G.; Kamae, T.; Kensei, S.; Kocevski, D.; Larsson, S.; Li, J.; Longo, F.; Loparco, F.; Lovellette, M. N.; Lubrano, P.; Maldera, S.; Manfreda, A.; Mazziotta, M. N.; Michelson, P. F.; Mizuno, T.; Monzani, M. E.; Morselli, A.; Negro, M.; Nuss, E.; Orienti, M.; Orlando, E.; Paneque, D.; Perkins, J. S.; Pesce-Rollins, M.; Piron, F.; Pivato, G.; Porter, T. A.; Principe, G.; Rainò, S.; Razzano, M.; Simone, D.; Siskind, E. J.; Spada, F.; Spinelli, P.; Thayer, J. B.; Torres, D. F.; Torresi, E.; Troja, E.; Vianello, G.; Wood, K. S.

    2017-04-01

    Context. The addition of a 28 m Cherenkov telescope (CT5) to the H.E.S.S. array extended the experiment's sensitivityto lower energies. The lowest energy threshold is obtained using monoscopic analysis of data taken with CT5, providing access to gamma-ray energies below 100 GeV for small zenith angle observations. Such an extension of the instrument's energy range is particularly beneficial for studies of active galactic nuclei with soft spectra, as expected for those at a redshift ≥0.5. The high-frequency peaked BL Lac objects PKS 2155-304 (z = 0.116) and PG 1553+113 (0.43 < z < 0.58) are among the brightest objects in the gamma-ray sky, both showing clear signatures of gamma-ray absorption at E > 100 GeV interpreted as being due to interactions with the extragalactic background light (EBL). Aims: The aims of this work are twofold: to demonstrate the monoscopic analysis of CT5 data with a low energy threshold, and to obtain accurate measurements of the spectral energy distributions (SED) of PKS 2155-304 and PG 1553+113 near their SED peaks at energies ≈100 GeV. Methods: Multiple observational campaigns of PKS 2155-304 and PG 1553+113 were conducted during 2013 and 2014 using the full H.E.S.S. II instrument (CT1-5). A monoscopic analysis of the data taken with the new CT5 telescope was developed along with an investigation into the systematic uncertainties on the spectral parameters which are derived from this analysis. Results: Using the data from CT5, the energy spectra of PKS 2155-304 and PG 1553+113 were reconstructed down to conservative threshold energies of 80 GeV for PKS 2155-304, which transits near zenith, and 110 GeV for the more northern PG 1553+113. The measured spectra, well fitted in both cases by a log-parabola spectral model (with a 5.0σ statistical preference for non-zero curvature for PKS 2155-304 and 4.5σ for PG 1553+113), were found consistent with spectra derived from contemporaneous Fermi-LAT data, indicating a sharp break in the observed spectra of both sources at E ≈ 100 GeV. When corrected for EBL absorption, the intrinsic H.E.S.S. II mono and Fermi-LAT spectrum of PKS 2155-304 was found to show significant curvature. For PG 1553+113, however, no significant detection of curvature in the intrinsic spectrum could be found within statistical and systematic uncertainties.

  17. Optimization of dose and image quality in adult and pediatric computed tomography scans

    NASA Astrophysics Data System (ADS)

    Chang, Kwo-Ping; Hsu, Tzu-Kun; Lin, Wei-Ting; Hsu, Wen-Lin

    2017-11-01

    Exploration to maximize CT image and reduce radiation dose was conducted while controlling for multiple factors. The kVp, mAs, and iteration reconstruction (IR), affect the CT image quality and radiation dose absorbed. The optimal protocols (kVp, mAs, IR) are derived by figure of merit (FOM) based on CT image quality (CNR) and CT dose index (CTDIvol). CT image quality metrics such as CT number accuracy, SNR, low contrast materials' CNR and line pair resolution were also analyzed as auxiliary assessments. CT protocols were carried out with an ACR accreditation phantom and a five-year-old pediatric head phantom. The threshold values of the adult CT scan parameters, 100 kVp and 150 mAs, were determined from the CT number test and line pairs in ACR phantom module 1and module 4 respectively. The findings of this study suggest that the optimal scanning parameters for adults be set at 100 kVp and 150-250 mAs. However, for improved low- contrast resolution, 120 kVp and 150-250 mAs are optimal. Optimal settings for pediatric head CT scan were 80 kVp/50 mAs, for maxillary sinus and brain stem, while 80 kVp /300 mAs for temporal bone. SNR is not reliable as the independent image parameter nor the metric for determining optimal CT scan parameters. The iteration reconstruction (IR) approach is strongly recommended for both adult and pediatric CT scanning as it markedly improves image quality without affecting radiation dose.

  18. Conventional 3D staging PET/CT in CT simulation for lung cancer: impact of rigid and deformable target volume alignments for radiotherapy treatment planning.

    PubMed

    Hanna, G G; Van Sörnsen De Koste, J R; Carson, K J; O'Sullivan, J M; Hounsell, A R; Senan, S

    2011-10-01

    Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans. 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTV(CT)) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice's similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan. When the GTV(CT) delineated on the staging scan after both rigid registration and deformation was compared with the GTV(CT)on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p = 0.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration. No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.

  19. Effects of self-paced interval and continuous training on health markers in women.

    PubMed

    Connolly, Luke J; Bailey, Stephen J; Krustrup, Peter; Fulford, Jonathan; Smietanka, Chris; Jones, Andrew M

    2017-11-01

    To compare the effects of self-paced high-intensity interval and continuous cycle training on health markers in premenopausal women. Forty-five inactive females were randomised to a high-intensity interval training (HIIT; n = 15), continuous training (CT; n = 15) or an inactive control (CON; n = 15) group. HIIT performed 5 × 5 min sets comprising repetitions of 30-s low-, 20-s moderate- and 10-s high-intensity cycling with 2 min rest between sets. CT completed 50 min of continuous cycling. Training was completed self-paced, 3 times weekly for 12 weeks. Peak oxygen uptake (16 ± 8 and 21 ± 12%), resting heart rate (HR) (-5 ± 9 and -4 ± 7 bpm) and visual and verbal learning improved following HIIT and CT compared to CON (P < 0.05). Total body mass (-0.7 ± 1.4 kg), submaximal walking HR (-3 ± 4 bpm) and verbal memory were enhanced following HIIT (P < 0.05), whereas mental well-being, systolic (-5 ± 6 mmHg) and mean arterial (-3 ± 5 mmHg) blood pressures were improved following CT (P < 0.05). Participants reported similar levels of enjoyment following HIIT and CT, and there were no changes in fasting serum lipids, fasting blood [glucose] or [glucose] during an oral glucose tolerance test following either HIIT or CT (P > 0.05). No outcome variable changed in the CON group (P > 0.05). Twelve weeks of self-paced HIIT and CT were similarly effective at improving cardiorespiratory fitness, resting HR and cognitive function in inactive premenopausal women, whereas blood pressure, submaximal HR, well-being and body mass adaptations were training-type-specific. Both training methods improved established health markers, but the adaptations to HIIT were evoked for a lower time commitment.

  20. Automated segmentation of knee and ankle regions of rats from CT images to quantify bone mineral density for monitoring treatments of rheumatoid arthritis

    NASA Astrophysics Data System (ADS)

    Cruz, Francisco; Sevilla, Raquel; Zhu, Joe; Vanko, Amy; Lee, Jung Hoon; Dogdas, Belma; Zhang, Weisheng

    2014-03-01

    Bone mineral density (BMD) obtained from a CT image is an imaging biomarker used pre-clinically for characterizing the Rheumatoid arthritis (RA) phenotype. We use this biomarker in animal studies for evaluating disease progression and for testing various compounds. In the current setting, BMD measurements are obtained manually by selecting the regions of interest from three-dimensional (3-D) CT images of rat legs, which results in a laborious and low-throughput process. Combining image processing techniques, such as intensity thresholding and skeletonization, with mathematical techniques in curve fitting and curvature calculations, we developed an algorithm for quick, consistent, and automatic detection of joints in large CT data sets. The implemented algorithm has reduced analysis time for a study with 200 CT images from 10 days to 3 days and has improved the robust detection of the obtained regions of interest compared with manual segmentation. This algorithm has been used successfully in over 40 studies.

  1. Fatigue Crack Growth Threshold Testing of Metallic Rotorcraft Materials

    NASA Technical Reports Server (NTRS)

    Newman, John A.; James, Mark A.; Johnson, William M.; Le, Dy D.

    2008-01-01

    Results are presented for a program to determine the near-threshold fatigue crack growth behavior appropriate for metallic rotorcraft alloys. Four alloys, all commonly used in the manufacture of rotorcraft, were selected for study: Aluminum alloy 7050, 4340 steel, AZ91E Magnesium, and Titanium alloy Ti-6Al-4V (beta-STOA). The Federal Aviation Administration (FAA) sponsored this research to advance efforts to incorporate damage tolerance design and analysis as requirements for rotorcraft certification. Rotorcraft components are subjected to high cycle fatigue and are typically subjected to higher stresses and more stress cycles per flight hour than fixed-wing aircraft components. Fatigue lives of rotorcraft components are generally spent initiating small fatigue cracks that propagate slowly under near-threshold cracktip loading conditions. For these components, the fatigue life is very sensitive to the near-threshold characteristics of the material.

  2. Twelve automated thresholding methods for segmentation of PET images: a phantom study.

    PubMed

    Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M

    2012-06-21

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical (18)F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.

  3. Twelve automated thresholding methods for segmentation of PET images: a phantom study

    NASA Astrophysics Data System (ADS)

    Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M.

    2012-06-01

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.

  4. Response of pMOS dosemeters on gamma-ray irradiation during its re-use.

    PubMed

    Pejovic, Milic M; Pejovic, Momcilo M; Jaksic, Aleksandar B

    2013-08-01

    Response of pMOS dosemeters during two successive irradiations with gamma-ray irradiation to a dose of 35 Gy and annealing at room and elevated temperature has been studied. The response was followed on the basis of threshold voltage shift, determined from transfer characteristics, as a function of absorbed dose or annealing time. It was shown that the threshold voltage shifts during first and second irradiation for the gate bias during irradiation of 5 and 2.5 V insignificantly differ although complete fading was not achieved after the first cycle of annealing. In order to analyse the defects formed in oxide and at the interface during irradiation and annealing, which are responsible for threshold voltage shift, midgap and charge-pumping techniques were used. It was shown that during first irradiation and annealing a dominant influence to threshold voltage shift is made by fixed oxide traps, while at the beginning of the second annealing cycle, threshold voltage shift is a consequence of both fixed oxide traps and slow switching traps.

  5. Ultra-high spatial resolution multi-energy CT using photon counting detector technology

    NASA Astrophysics Data System (ADS)

    Leng, S.; Gutjahr, R.; Ferrero, A.; Kappler, S.; Henning, A.; Halaweish, A.; Zhou, W.; Montoya, J.; McCollough, C.

    2017-03-01

    Two ultra-high-resolution (UHR) imaging modes, each with two energy thresholds, were implemented on a research, whole-body photon-counting-detector (PCD) CT scanner, referred to as sharp and UHR, respectively. The UHR mode has a pixel size of 0.25 mm at iso-center for both energy thresholds, with a collimation of 32 × 0.25 mm. The sharp mode has a 0.25 mm pixel for the low-energy threshold and 0.5 mm for the high-energy threshold, with a collimation of 48 × 0.25 mm. Kidney stones with mixed mineral composition and lung nodules with different shapes were scanned using both modes, and with the standard imaging mode, referred to as macro mode (0.5 mm pixel and 32 × 0.5 mm collimation). Evaluation and comparison of the three modes focused on the ability to accurately delineate anatomic structures using the high-spatial resolution capability and the ability to quantify stone composition using the multi-energy capability. The low-energy threshold images of the sharp and UHR modes showed better shape and texture information due to the achieved higher spatial resolution, although noise was also higher. No noticeable benefit was shown in multi-energy analysis using UHR compared to standard resolution (macro mode) when standard doses were used. This was due to excessive noise in the higher resolution images. However, UHR scans at higher dose showed improvement in multi-energy analysis over macro mode with regular dose. To fully take advantage of the higher spatial resolution in multi-energy analysis, either increased radiation dose, or application of noise reduction techniques, is needed.

  6. Ring test evaluation of the detection of influenza A virus in swine oral fluids by real-time reverse-transcription polymerase chain reaction and virus isolation

    PubMed Central

    Goodell, Christa K.; Zhang, Jianqiang; Strait, Erin; Harmon, Karen; Patnayak, Devi; Otterson, Tracy; Culhane, Marie; Christopher-Hennings, Jane; Clement, Travis; Leslie-Steen, Pamela; Hesse, Richard; Anderson, Joe; Skarbek, Kevin; Vincent, Amy; Kitikoon, Pravina; Swenson, Sabrina; Jenkins-Moore, Melinda; McGill, Jodi; Rauh, Rolf; Nelson, William; O’Connell, Catherine; Shah, Rohan; Wang, Chong; Main, Rodger; Zimmerman, Jeffrey J.

    2016-01-01

    The probability of detecting influenza A virus (IAV) in oral fluid (OF) specimens was calculated for each of 13 assays based on real-time reverse-transcription polymerase chain reaction (rRT-PCR) and 7 assays based on virus isolation (VI). The OF specimens were inoculated with H1N1 or H3N2 IAV and serially diluted 10-fold (10−1 to 10−8). Eight participating laboratories received 180 randomized OF samples (10 replicates × 8 dilutions × 2 IAV subtypes plus 20 IAV-negative samples) and performed the rRT-PCR and VI procedure(s) of their choice. Analysis of the results with a mixed-effect logistic-regression model identified dilution and assay as variables significant (P < 0.0001) for IAV detection in OF by rRT-PCR or VI. Virus subtype was not significant for IAV detection by either rRT-PCR (P = 0.457) or VI (P = 0.101). For rRT-PCR the cycle threshold (Ct) values increased consistently with dilution but varied widely. Therefore, it was not possible to predict VI success on the basis of Ct values. The success of VI was inversely related to the dilution of the sample; the assay was generally unsuccessful at lower virus concentrations. Successful swine health monitoring and disease surveillance require assays with consistent performance, but significant differences in reproducibility were observed among the assays evaluated. PMID:26733728

  7. Discerning Viable from Nonviable Yersinia pestis pgm- and Bacillus anthracis Sterne using Propidium Monoazide in the Presence of White Powders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hess, Becky M.; Kaiser, Brooke LD; Sydor, Michael A.

    ABSTRACT Aims To develop and optimize an assay to determine viability status of Bacillus anthracis Sterne and Yersinia pestis pgm- strains in the presence of white powders by coupling propidium monoazide (PMA) treatment with real-time PCR (qPCR) analysis. Methods and Results PMA selectively enters nonviable cells and binds DNA, thereby increasing qPCR assay cycle threshold (CT) values compared to untreated samples. Dye concentration, cell number and fitness, incubation time, inactivation methods, and assay buffer were optimized for B. anthracis Sterne and Y. pestis pgm-. Differences in CT values in nonviable cells compared to untreated samples were consistently > 9 formore » both B. anthracis Sterne vegetative cells and Y. pestis pgm- in the presence and absence of three different white powders. Our method eliminates the need for a DNA extraction step prior to detection by qPCR. Conclusions The developed assay enables simultaneous identification and viability assessment for B. anthracis Sterne and Y. pestis pgm- under laboratory conditions, even in the presence of white powders. Eliminating the DNA extraction step that is typically used reduces total assay time and labor requirements for sample analysis. Significance and Impact of the Study The method developed for simultaneous detection and viability assessment for B. anthracis and Y. pestis can be employed in forming decisions about the severity of a biothreat event or the safety of food. Keywords Bacillus anthracis, Yersinia pestis, Propidium Monoazide, qPCR, White Powders, Rapid Viability Detection« less

  8. Development of real-time PCR assay for genetic identification of the mottled skate, Beringraja pulchra.

    PubMed

    Hwang, In Kwan; Lee, Hae Young; Kim, Min-Hee; Jo, Hyun-Su; Choi, Dong-Ho; Kang, Pil-Won; Lee, Yang-Han; Cho, Nam-Soo; Park, Ki-Won; Chae, Ho Zoon

    2015-10-01

    The mottled skate, Beringraja pulchra is one of the commercially important fishes in the market today. However, B. pulchra identification methods have not been well developed. The current study reports a novel real-time PCR method based on TaqMan technology developed for the genetic identification of B. pulchra. The mitochondrial cytochrome oxidase subunit 1 (COI) nucleotide sequences of 29 B. pulchra, 157 skates and rays reported in GenBank DNA database were comparatively analyzed and the COI sequences specific to B. pulchra was identified. Based on this information, a system of specific primers and Minor Groove Binding (MGB) TaqMan probe were designed. The assay successfully discriminated in 29 specimens of B. pulchra and 27 commercial samples with unknown species identity. For B. pulchra DNA, an average Threshold Cycle (Ct) value of 19.1±0.1 was obtained. Among 27 commercial samples, two samples showed average Ct values 19.1±0.0 and 26.7±0.1, respectively and were confirmed to be B. pulchra based on sequencing. The other samples tested showed undetectable or extremely weak signals for the target fragment, which was also consistent with the sequencing results. These results reveal that the method developed is a rapid and efficient tool to identify B. pulchra and might prevent fraud or mislabeling during the distribution of B. pulchra products. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Evaluation of endogenous control gene(s) for gene expression studies in human blood exposed to 60Co γ-rays ex vivo.

    PubMed

    Vaiphei, S Thangminlal; Keppen, Joshua; Nongrum, Saibadaiahun; Chaubey, R C; Kma, L; Sharan, R N

    2015-01-01

    In gene expression studies, it is critical to normalize data using a stably expressed endogenous control gene in order to obtain accurate and reliable results. However, we currently do not have a universally applied endogenous control gene for normalization of data for gene expression studies, particularly those involving (60)Co γ-ray-exposed human blood samples. In this study, a comparative assessment of the gene expression of six widely used housekeeping endogenous control genes, namely 18S, ACTB, B2M, GAPDH, MT-ATP6 and CDKN1A, was undertaken for a range of (60)Co γ-ray doses (0.5, 1.0, 2.0 and 4.0 Gy) at 8.4 Gy min(-1) at 0 and 24 h post-irradiation time intervals. Using the NormFinder algorithm, real-time PCR data obtained from six individuals (three males and three females) were analyzed with respect to the threshold cycle (Ct) value and abundance, ΔCt pair-wise comparison, intra- and inter-group variability assessments, etc. GAPDH, either alone or in combination with 18S, was found to be the most suitable endogenous control gene and should be used in gene expression studies, especially those involving qPCR of γ-ray-exposed human blood samples. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  10. SUVmax/THKmax as a Biomarker for Distinguishing Advanced Gastric Carcinoma from Primary Gastric Lymphoma

    PubMed Central

    Fu, Liping; Li, Hongming; Wang, Hui; Xu, Baixuan; Fan, Yong; Tian, Jiahe

    2012-01-01

    Background Gastric carcinoma and primary gastric lymphoma (PGL) are the two most common malignancies in stomach. The purpose of this study was to screen and validate a biomarker of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for distinguishing advanced gastric carcinoma (AGC) from PGL for clinical applications. Methodology/Principal Findings We reviewed PET/CT scans collected from January 2008 to April 2012 of 69 AGC and 38 PGL (14 low-grade mucosa-associated lymphoid tissue [MALT], 24 non-MALT aggressive non-Hodgkin lymphoma [ANHL]) with a focus on FDG intensity (maximum standardized uptake value [SUVmax]) of primary lesions and its CT-detected abnormalities, including maximal gastrointestinal wall thickness (THKmax) and mucosal ulcerations. Gastric FDG uptake was found in 69 (100%) patients with AGC and 36 (95%, 12 MALT vs. 24 ANHL)with PGL. The presence of CT-detected abnormalities of AGC and PGL were 97% (67/69) and 89% (12 MALT vs. 22 ANHL), respectively. After controlling for THKmax, SUVmax was higher with ANHL than AGC (17.10±8.08 vs. 9.65±5.24, p<0.05) and MALT (6.20±3.60, p<0.05). THKmax did not differ among MALT, ANHL and AGC. Mucosal ulceration was more common with AGC (n = 9) than PGL (n = 2),but the difference was not statistically significant (p>0.05). Cross-validation analysis showed that for distinguishing ANHL from AGC, the classifier with SUVmax as a feature achieved a correct classification rate of 81% with thresholds 13.40±1.12 and the classifier with SUVmax/THKmax as a feature achieved a correct classification rate of 83% with thresholds 7.51±0.63. Conclusions/Significance SUVmax/THKmax may be as a promising biomarker of FDG-PET/CT for distinguishing ANHL from AGC. Structural CT abnormalities alone may not be reliable but can help with PET assessment of gastric malignancies. 18F-FDG PET/CT have potential for distinguishing AGC from PGL at the individual level. PMID:23226547

  11. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    PubMed

    Mui, Leonora W; Engelsohn, Eliyahu; Umans, Hilary

    2007-02-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury.

  12. Microhematuria Associated With a Special Operations Craft Mission

    DTIC Science & Technology

    2004-09-22

    proteinuria at 5 minutes and 1 hour following three 60-second Wingate tests, a 60-minute treadmill run at 90% of anaerobic threshold , a 60-minute cycle...ergometer ride at 90% of anaerobic threshold , and three 400-meter sprints. Of these only the sprints produced microhematuria on average. All ten...Ulmer, H., et al. (2003). The effect of marathon cycling on renal function. Int J Sports Med, 24(2), 131-137. [7] Alvarez, C., Mir, J., Obaya, S

  13. Neoadjuvant chemotherapy in breast cancer: prediction of pathologic response with PET/CT and dynamic contrast-enhanced MR imaging--prospective assessment.

    PubMed

    Tateishi, Ukihide; Miyake, Mototaka; Nagaoka, Tomoaki; Terauchi, Takashi; Kubota, Kazunori; Kinoshita, Takayuki; Daisaki, Hiromitsu; Macapinlac, Homer A

    2012-04-01

    To clarify whether fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging performed after two cycles of neoadjuvant chemotherapy (NAC) can be used to predict pathologic response in breast cancer. Institutional human research committee approval and written informed consent were obtained. Accuracy after two cycles of NAC for predicting pathologic complete response (pCR) was examined in 142 women (mean age, 57 years: range, 43-72 years) with histologically proved breast cancer between December 2005 and February 2009. Quantitative PET/CT and DCE MR imaging were performed at baseline and after two cycles of NAC. Parameters of PET/CT and of blood flow and microvascular permeability at DCE MR were compared with pathologic response. Patients were also evaluated after NAC by using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 based on DCE MR measurements and European Organization for Research and Treatment of Cancer (EORTC) criteria and PET Response Criteria in Solid Tumors (PERCIST) 1.0 based on PET/CT measurements. Multiple logistic regression analyses were performed to examine continuous variables at PET/CT and DCE MR to predict pCR, and diagnostic accuracies were compared with the McNemar test. Significant decrease from baseline of all parameters at PET/CT and DCE MR was observed after NAC. Therapeutic response was obtained in 24 patients (17%) with pCR and 118 (83%) without pCR. Sensitivity, specificity, and accuracy to predict pCR were 45.5%, 85.5%, and 82.4%, respectively, with RECIST and 70.4%, 95.7%, and 90.8%, respectively, with EORTC and PERCIST. Multiple logistic regression revealed three significant independent predictors of pCR: percentage maximum standardized uptake value (%SUV(max)) (odds ratio [OR], 1.22; 95% confidence interval [CI]: 1.11, 1.34; P < .0001), percentage rate constant (%k(ep)) (OR, 1.07; CI: 1.03, 1.12; P = .002), and percentage area under the time-intensity curve over 90 seconds (%AUC(90)) (OR, 1.04; CI: 1.01, 1.07; P = .048). When diagnostic accuracies are compared, PET/CT is superior to DCE MR for the prediction of pCR (%SUV(max) [90.1%] vs %κ(ep) [83.8%] or %AUC(90) [76.8%]; P < .05). The sensitivities of %SUV(max) (66.7%), %k(ep) (51.7%), and %AUC(90) (50.0%) at (18)F-FDG PET/CT and DCE MR after two cycles of NAC are not acceptable, but the specificities (96.4%, 92.0%, and 95.2%, respectively) are high for stratification of pCR cases in breast cancer. © RSNA, 2012.

  14. Longitudinal studies of the 18F-FDG kinetics after ipilimumab treatment in metastatic melanoma patients based on dynamic FDG PET/CT.

    PubMed

    Sachpekidis, Christos; Anwar, Hoda; Winkler, Julia K; Kopp-Schneider, Annette; Larribere, Lionel; Haberkorn, Uwe; Hassel, Jessica C; Dimitrakopoulou-Strauss, Antonia

    2018-06-05

    Immunotherapy has raised the issue of appropriate treatment response evaluation, due to the unique mechanism of action of the immunotherapeutic agents. Aim of this analysis is to evaluate the potential role of quantitative analysis of 2-deoxy-2-( 18 F)fluoro-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) data in monitoring of patients with metastatic melanoma undergoing ipilimumab therapy. 25 patients with unresectable metastatic melanoma underwent dynamic PET/CT (dPET/CT) of the thorax and upper abdomen as well as static, whole body PET/CT with 18 F-FDG before the start of ipilimumab treatment (baseline PET/CT), after two cycles of treatment (interim PET/CT) and at the end of treatment after four cycles (late PET/CT). The evaluation of dPET/CT studies was based on semi-quantitative (standardized uptake value, SUV) calculation as well as quantitative analysis, based on two-tissue compartment modeling and a fractal approach. Patients' best clinical response, assessed at a mean of 59 weeks, was used as reference. According to their best clinical response, patients were dichotomized in those demonstrating clinical benefit (CB, n = 16 patients) and those demonstrating no clinical benefit (no-CB, n = 9 patients). No statistically significant differences were observed between CB and no-CB regarding either semi-quantitative or quantitative parameters in all scans. On contrary, the application of the recently introduced PET response evaluation criteria for immunotherapy (PERCIMT) led to a correct classification rate of 84% (21/25 patients). Quantitative analysis of 18 F-FDG PET data does not provide additional information in treatment response evaluation of metastatic melanoma patients receiving ipilimumab. PERCIMT criteria correlated better with clinical response.

  15. Concomitant chemoradiotherapy versus induction docetaxel, cisplatin and 5 fluorouracil (TPF) followed by concomitant chemoradiotherapy in locally advanced head and neck cancer: a phase II randomized study.

    PubMed

    Paccagnella, A; Ghi, M G; Loreggian, L; Buffoli, A; Koussis, H; Mione, C A; Bonetti, A; Campostrini, F; Gardani, G; Ardizzoia, A; Dondi, D; Guaraldi, M; Cavallo, R; Tomio, L; Gava, A

    2010-07-01

    Concomitant chemoradiotherapy (CT/RT) is the standard treatment of locally advanced squamous cell carcinoma of the head and neck (SCCHN). We evaluated the efficacy of induction docetaxel (Taxotere), cisplatin, and 5-fluorouracil (TPF) before CT/RT versus CT/RT alone. Patients with stage III-IVM0 SCCHN, Eastern Cooperative Oncology Group performance status of zero to one, were randomly assigned to receive CT/RT alone (arm A: two cycles of cisplatin 20 mg/m(2), days1-4, plus 5-fluorouracil 800 mg/m(2)/day 96 h continuous infusion, during weeks 1 and 6 of radiotherapy) or three cycles of TPF (arm B: docetaxel 75 mg/m(2) and cisplatin 80 mg/m(2), day 1, and 5-fluorouracil 800 mg/m(2)/day 96 h continuous infusion, every 3 weeks) followed by the same CT/RT. The primary end point was the rate of radiologic complete response (CR) at 6-8 weeks after the end of CT/RT. A total of 101 patients were randomly allocated to the study (51 arm A; 50 arm B). CR rates were 21.2% (arm A) versus 50% (arm B). Median progression-free survival and overall survival were, respectively, 19.7 and 33.3 months (arm A) and 30.4 and 39.6 months (arm B). Hematologic and non-hematologic toxic effects during CT/RT were similar in the two arms. Induction TPF followed by CT/RT was associated with higher radiologic CR in patients with locally advanced SCCHN with no negative impact on CT/RT feasibility.

  16. A Climatology of dust emission in northern Africa using surface observations from 1984-2012

    NASA Astrophysics Data System (ADS)

    Cowie, Sophie; Knippertz, Peter; Marsham, John

    2014-05-01

    The huge quantity of mineral dust emitted annually from northern Africa makes this area crucial to the global dust cycle. Once in the atmosphere, dust aerosols have a significant impact on the global radiation budget, clouds, the carbon cycle and can even act as a fertilizer to rain forests in South America. Current model estimates of dust production from northern Africa are uncertain. At the heart of this problem is insufficient understanding of key dust emitting processes such as haboobs (cold pools generated through evaporation of convective precipitation), low-level jets (LLJs) and dry convection (dust devils and dust plumes). Scarce observations in this region, in particular in the Sahara, make model evaluation difficult. This work uses long-term surface observations from 70 stations situated in the Sahara and Sahel to explore the diurnal, seasonal and geographical variations in dust emission events and thresholds. Quality flags are applied to each station to indicate a day-time bias or gaps in the time period 1984-2012. The frequency of dust emission (FDE) is calculated using the present weather codes (WW) of SYNOP reports, where WW = 07,08,09,30-35 and 98. Thresholds are investigated by estimating the wind speeds for which there is a 25%, 50% and 75% probability of dust emission. The 50% threshold is used to calculate strong wind frequency (SWF) and the diagnostic parameter dust uplift potential (DUP); a thresholded cubic function of wind-speed which quantifies the dust generating power of winds. Stations are grouped into 6 areas (North Algeria, Central Sahara, Egypt, West Sahel, Central Sahel and Sudan) for more in-depth analysis of these parameters. Spatially, thresholds are highest in northern Algeria and lowest in the Sahel around the latitude band 16N-21N. Annual mean FDE is anti-correlated with the threshold, showing the importance of spatial variations in thresholds for mean dust emission. The annual cycles of FDE and SWF for the 6 grouped areas are highly correlated (0.95 to 0.99). These correlations are barely reduced when annual-mean thresholds are used, showing that seasonal variations in thresholds are not the main control on the seasonal variations in FDE. Relationships between annual cycles in FDE and DUP are more complex than between FDE and SWF, reflecting the seasonal variations in the types and intensities of dust events. FDE is highest in spring north of 23N. South of this, where stations are directly influenced by the summer monsoon, the annual cycle in FDE is much more variable. Half of the total DUP occurs at wind-speeds greater than ~ 28 ms-1, which highlights the importance of rare high-energy wind events. The likely meteorological mechanisms generating these patterns are discussed.

  17. Cost-effectiveness of sialendoscopy versus medical management for radioiodine-induced sialadenitis.

    PubMed

    Kowalczyk, David M; Jordan, J Randall; Stringer, Scott P

    2018-03-30

    The medical management and radiographic identification of radioiodine-induced sialadenitis (RAIS) is challenging. This study utilizes a cost-effectiveness analysis to compare upfront sialendoscopy as both a diagnostic and therapeutic option versus multiple modalities of diagnostic radiography along with medical management. Literature review and cost-effectiveness analysis. A literature review was performed to identify the outcomes of medical management, sialendoscopy, diagnostic radiography, and surgical complications. All charges were obtained from the University of Mississippi Budget Office in 2017 US dollars and converted to costs using the 2017 Medicare Cost-to-Charge Ratio for urban medical centers. A cost-effectiveness analysis was used to evaluate the four treatment arms-sialendoscopy, medical management- ultrasound, medical management-computed tomography (CT) sialography, and medical management-magnetic resonance (MR) sialography. Sensitivity analyses were used to evaluate the confidence levels of the economic evaluation. The incremental cost-effectiveness ratio for upfront sialendoscopy versus medical management-ultrasound was $30,402.30, which demonstrates that sialendoscopy is the more cost-effective option given a willingness-to-pay threshold of $50,000. The probability that this decision is correct at a willingness-to-pay of $50,000 is 64.5%. Sialendoscopic improvement was the most sensitive variable requiring a threshold of 0.70. Of the three imaging modalities, ultrasound dominated MR and CT sialography, both of which required a willingness-to-pay of greater than $90,000 to realize a difference. Upfront sialendoscopy is more cost-effective compared to medical management utilizing diagnostic ultrasound assuming a willingness-to-pay threshold of $50,000. There is a clear cost-effectiveness to using ultrasound with medical management over CT and MR sialography in the diagnosis and management of RAIS. NA. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Aortic valve calcifications on chest films: how much calcium do I need?

    PubMed

    Mahnken, Andreas H; Dohmen, Guido; Koos, Ralf

    2011-08-01

    Aortic valve calcifications (AVC) as seen on conventional chest films or on CT are associated with aortic valve stenosis (AVS). The absence of AVC on chest films does not exclude high grade AVS. The aim of this study was to analyse if there is a threshold for the detection of AVC from conventional chest films in patients suffering from high grade AVS. The explanted aortic valves of 29 patients (16 male, mean age 72.3 +/- 11.5 years) with high grade AVS were examined by dual-source CT. AVC were quantified using the Agatston AVC score. In all patients conventional chest films obtained the day before surgery were evaluated for the presence of AVC. Results were analysed with students t-test, Spearman's rank correlation and ROC analysis. On conventional chest films AVC were visible in 18 patients. On CT all specimen presented with AVC with an Agatston AVC score ranging from 40.7 to 1870 (mean 991.3 +/- 463.1). In patients with AVC visible on chest films the AVC score was significantly higher (1264.0 +/- 318.2) when compared with patients without visible calcifications (544.9 +/- 274.4; P < 0.0001). There was a strong correlation between the AVC score and the visibility of AVC on chest films (r = 0.781). ROC analysis identified an ideal threshold of 718 for AVC score to separate conventional chest films with and without visible AVC. Unlike in coronary calcifications, there is a threshold for identifying AVC from conventional chest films. This finding may be of diagnostic value, as conventional chest films may be used to semiquantitatively evaluate the extent of AVC.

  19. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Nan-Jie; Wong, Chun-Sing, E-mail: drcswong@gmail.com; Chu, Yiu-Ching

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using themore » proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.« less

  20. Comparison of four software packages for CT lung volumetry in healthy individuals.

    PubMed

    Nemec, Stefan F; Molinari, Francesco; Dufresne, Valerie; Gosset, Natacha; Silva, Mario; Bankier, Alexander A

    2015-06-01

    To compare CT lung volumetry (CTLV) measurements provided by different software packages, and to provide normative data for lung densitometric measurements in healthy individuals. This retrospective study included 51 chest CTs of 17 volunteers (eight men and nine women; mean age, 30 ± 6 years), who underwent spirometrically monitored CT at total lung capacity (TLC), functional residual capacity (FRC), and mean inspiratory capacity (MIC). Volumetric differences assessed by four commercial software packages were compared with analysis of variance (ANOVA) for repeated measurements and benchmarked against the threshold for acceptable variability between spirometric measurements. Mean lung density (MLD) and parenchymal heterogeneity (MLD-SD) were also compared with ANOVA. Volumetric differences ranged from 12 to 213 ml (0.20 % to 6.45 %). Although 16/18 comparisons (among four software packages at TLC, MIC, and FRC) were statistically significant (P < 0.001 to P = 0.004), only 3/18 comparisons, one at MIC and two at FRC, exceeded the spirometry variability threshold. MLD and MLD-SD significantly increased with decreasing volumes, and were significantly larger in lower compared to upper lobes (P < 0.001). Lung volumetric differences provided by different software packages are small. These differences should not be interpreted based on statistical significance alone, but together with absolute volumetric differences. • Volumetric differences, assessed by different CTLV software, are small but statistically significant. • Volumetric differences are smaller at TLC than at MIC and FRC. • Volumetric differences rarely exceed spirometric repeatability thresholds at MIC and FRC. • Differences between CTLV measurements should be interpreted based on comparison of absolute differences. • MLD increases with decreasing volumes, and is larger in lower compared to upper lobes.

  1. Physiological differences between cycling and running: lessons from triathletes.

    PubMed

    Millet, Gregoire P; Vleck, V E; Bentley, D J

    2009-01-01

    The purpose of this review was to provide a synopsis of the literature concerning the physiological differences between cycling and running. By comparing physiological variables such as maximal oxygen consumption (V O(2max)), anaerobic threshold (AT), heart rate, economy or delta efficiency measured in cycling and running in triathletes, runners or cyclists, this review aims to identify the effects of exercise modality on the underlying mechanisms (ventilatory responses, blood flow, muscle oxidative capacity, peripheral innervation and neuromuscular fatigue) of adaptation. The majority of studies indicate that runners achieve a higher V O(2max) on treadmill whereas cyclists can achieve a V O(2max) value in cycle ergometry similar to that in treadmill running. Hence, V O(2max) is specific to the exercise modality. In addition, the muscles adapt specifically to a given exercise task over a period of time, resulting in an improvement in submaximal physiological variables such as the ventilatory threshold, in some cases without a change in V O(2max). However, this effect is probably larger in cycling than in running. At the same time, skill influencing motor unit recruitment patterns is an important influence on the anaerobic threshold in cycling. Furthermore, it is likely that there is more physiological training transfer from running to cycling than vice versa. In triathletes, there is generally no difference in V O(2max) measured in cycle ergometry and treadmill running. The data concerning the anaerobic threshold in cycling and running in triathletes are conflicting. This is likely to be due to a combination of actual training load and prior training history in each discipline. The mechanisms surrounding the differences in the AT together with V O(2max) in cycling and running are not largely understood but are probably due to the relative adaptation of cardiac output influencing V O(2max) and also the recruitment of muscle mass in combination with the oxidative capacity of this mass influencing the AT. Several other physiological differences between cycling and running are addressed: heart rate is different between the two activities both for maximal and submaximal intensities. The delta efficiency is higher in running. Ventilation is more impaired in cycling than in running. It has also been shown that pedalling cadence affects the metabolic responses during cycling but also during a subsequent running bout. However, the optimal cadence is still debated. Central fatigue and decrease in maximal strength are more important after prolonged exercise in running than in cycling.

  2. Clinical outcome of patients with early stage favorable Hodgkin lymphoma treated with ABVD × two cycles followed by FDG-PET/CT restaging and 20 Gy of involved-site radiotherapy.

    PubMed

    Kamran, Sophia C; Jacene, Heather A; Chen, Yu-Hui; Mauch, Peter M; Ng, Andrea K

    2018-06-01

    Our purpose was to assess outcome of patients with early-stage, favorable (per GHSG criteria) Hodgkin Lymphoma (HL) staged with FDG-PET/CT and treated with two cycles of adriamycin, bleomycin, vincristine, and dacarbazine (ABVD) followed by PET/CT assessment and involved-site radiotherapy (ISRT) to 20 Gy. Records of 23 patients who met eligibility criteria, treated between 2008 and 2016, were reviewed. PET response after two cycles of ABVD was independently assessed by a nuclear medicine physician. After two cycles of ABVD, 91.3% of patients had a Deauville score of 1-2; 1 patient had a score of 3. Median follow-up was 45.3 months. As of this analysis, all patients are alive without disease. One patient had an out-of-field relapse, yielding a 4-year relapse-free survival rate of 92.9% (95%CI [59.1, 99.0]). Our results showed that with careful patient selection by initial disease characteristics and FDG-PET response to chemotherapy, the use of a more restricted treatment volume of ISRT to 20 Gy following ABVD × 2 is associated with excellent outcomes.

  3. Assessment of benefits of conservation agriculture on soil functions in arable production systems in Europe

    USDA-ARS?s Scientific Manuscript database

    Conventional tillage (CT), with reduced alternatives in crop rotation (monocropping), is the norm in European farming. CT may cause adverse effects on some of the five major soil functions, viz. primary productivity, carbon sequestration and regulation, nutrient cycling and provision, water regulati...

  4. (99m)Tc-3PRGD 2 SPECT/CT predicts the outcome of advanced nonsquamous non-small cell lung cancer receiving chemoradiotherapy plus bevacizumab.

    PubMed

    Ma, Qingjie; Min, Kaiyin; Wang, Ting; Chen, Bin; Wen, Qiang; Wang, Fan; Ji, Tiefeng; Gao, Shi

    2015-07-01

    Functional imaging can help clinicians assess the individual response of advanced nonsquamous non-small cell lung cancer (NSCLC) to chemoradiation therapy plus bevacizumab. Our purpose is to investigate the ability of (99m)Tc-3PRGD2 single photon emission computed tomography/computed tomography (SPECT/CT) in predicting the early response to treatment. Patients with advanced nonsquamous NSCLC diagnosed by histological or cytological examination were imaged with (99m)Tc-3PRGD2 SPECT/CT at 3 time points: 1-3 days before the start of treatment (SPECT1), 40 Gy radiotherapy with 2 cycles of chemotherapy plus bevacizumab (SPECT2) and 4 weeks after chemoradiotherapy plus bevacizumab (SPECT3). The images were evaluated semiquantitatively by measuring the tumor to non-tumor ratio (T/N) and calculating the percentage change in T/N ratio. Short-term outcome was assessed by the treatment response evaluation according to the Response Evaluation Criteria in Solid Tumors criteria as: complete response (CR), partial response (PR), stable disease (SD) and progressive disease (PD). Patients were divided two groups: responders (CR and PR) and nonresponders (SD and PD). To determine a threshold for percent reduction in T/N ratios, receiver-operating characteristic (ROC) curve analysis was used. Patients were grouped again based on the threshold of P1 (the change percentage from SPECT1 to SPECT2) and P2 (the change percentage from SPECT1 to SPECT3): P1 responders and P1 nonresponders; P2 responders and P2 nonresponders. Patients were followed up starting 4 weeks after completion of therapy and then every 3 months for the first 2 years and every 6 months after 2 years. OS of P1 responders, P1 nonresponders, P2 responders and P2 nonresponders was estimated and graphically illustrated using the Kaplan-Meier method and the log-rank test was used to test the null hypotheses of equal OS in subgroups of patients. A total of 28 patients completed all imaging and treatment. All primary lung tumors were well visualized on SPECT1. The mean T/N ratio of SPECT1 in responders and nonresponders was not statistically different (2.73 ± 0.59 vs. 2.59 ± 0.52, p > 0.05). At SPECT2 and SPECT3, the mean T/N ratios were both lower in the responders compared with the nonresponders and had statistical significance (p < 0.05). P1 and P2 in the responders was larger than the nonresponders with significant difference (P1: 34.18 ± 21.55 % vs. 9.02 ± 14.02 %, p < 0.05; P2: 53.02 ± 15.50 % vs. 7.74 ± 37.95 %, p < 0.05). The optimal threshold of P1 that can discriminate between P1 responders and P1 nonresponders was greater than 25.9 % reduction, and that of P2 that can discriminate between P2 responders and P2 nonresponders was 34.0 % reduction. The area under the ROC curve (AUC) of P1 and P2 for determining residual disease was 0.856 and 0.909, respectively; but there was no statistical significance between them (p > 0.05). There was a significant difference for OS between P1 responders and P1 nonresponders (p < 0.05), and also for OS between P2 responders and P2 nonresponders (p < 0.05). But there was no difference between the P1 responders and P2 responders (p > 0.05), or between the P1 nonresponders and P2 nonresponders (p > 0.05). A (99m)Tc-3PRGD2 SPECT/CT after two cycles of chemoradiotherapy plus bevacizumab can predict patients who will have a better response to treatment and survival.

  5. VirSSPA- a virtual reality tool for surgical planning workflow.

    PubMed

    Suárez, C; Acha, B; Serrano, C; Parra, C; Gómez, T

    2009-03-01

    A virtual reality tool, called VirSSPA, was developed to optimize the planning of surgical processes. Segmentation algorithms for Computed Tomography (CT) images: a region growing procedure was used for soft tissues and a thresholding algorithm was implemented to segment bones. The algorithms operate semiautomati- cally since they only need seed selection with the mouse on each tissue segmented by the user. The novelty of the paper is the adaptation of an enhancement method based on histogram thresholding applied to CT images for surgical planning, which simplifies subsequent segmentation. A substantial improvement of the virtual reality tool VirSSPA was obtained with these algorithms. VirSSPA was used to optimize surgical planning, to decrease the time spent on surgical planning and to improve operative results. The success rate increases due to surgeons being able to see the exact extent of the patient's ailment. This tool can decrease operating room time, thus resulting in reduced costs. Virtual simulation was effective for optimizing surgical planning, which could, consequently, result in improved outcomes with reduced costs.

  6. Validation of a new algorithm for a quick and easy RT-PCR-based ALK test in a large series of lung adenocarcinomas: Comparison with FISH, immunohistochemistry and next generation sequencing assays.

    PubMed

    Marchetti, Antonio; Pace, Maria Vittoria; Di Lorito, Alessia; Canarecci, Sara; Felicioni, Lara; D'Antuono, Tommaso; Liberatore, Marcella; Filice, Giampaolo; Guetti, Luigi; Mucilli, Felice; Buttitta, Fiamma

    2016-09-01

    Anaplastic Lymphoma Kinase (ALK) gene rearrangements have been described in 3-5% of lung adenocarcinomas (ADC) and their identification is essential to select patients for treatment with ALK tyrosine kinase inhibitors. For several years, fluorescent in situ hybridization (FISH) has been considered as the only validated diagnostic assay. Currently, alternative methods are commercially available as diagnostic tests. A series of 217 ADC comprising 196 consecutive resected tumors and 21 ALK FISH-positive cases from an independent series of 702 ADC were investigated. All specimens were screened by IHC (ALK-D5F3-CDx-Ventana), FISH (Vysis ALK Break-Apart-Abbott) and RT-PCR (ALK RGQ RT-PCR-Qiagen). Results were compared and discordant cases subjected to Next Generation Sequencing. Thirty-nine of 217 samples were positive by the ALK RGQ RT-PCR assay, using a threshold cycle (Ct) cut-off ≤35.9, as recommended. Of these positive samples, 14 were negative by IHC and 12 by FISH. ALK RGQ RT-PCR/FISH discordant cases were analyzed by the NGS assay with results concordant with FISH data. In order to obtain the maximum level of agreement between FISH and ALK RGQ RT-PCR data, we introduced a new scoring algorithm based on the ΔCt value. A ΔCt cut-off level ≤3.5 was used in a pilot series. Then the algorithm was tested on a completely independent validation series. By using the new scoring algorithm and FISH as reference standard, the sensitivity and the specificity of the ALK RGQ RT-PCR(ΔCt) assay were 100% and 100%, respectively. Our results suggest that the ALK RGQ RT-PCR test could be useful in clinical practice as a complementary assay in multi-test diagnostic algorithms or even, if our data will be confirmed in independent studies, as a standalone or screening test for the selection of patients to be treated with ALK inhibitors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Evaluation of Two Matrices for Long-Term, Ambient Storage of Bacterial DNA.

    PubMed

    Miernyk, Karen M; DeByle, Carolynn K; Rudolph, Karen M

    2017-12-01

    Culture-independent molecular analyses allow researchers to identify diverse microorganisms. This approach requires microbiological DNA repositories. The standard for DNA storage is liquid nitrogen or ultralow freezers. These use large amounts of space, are costly to operate, and could fail. Room temperature DNA storage is a viable alternative. In this study, we investigated storage of bacterial DNA using two ambient storage matrices, Biomatrica DNAstable ® Plus and GenTegra ® DNA. We created crude and clean DNA extracts from five Streptococcus pneumoniae isolates. Extracts were stored at -30°C (our usual DNA storage temperature), 25°C (within the range of temperatures recommended for the products), and 50°C (to simulate longer storage time). Samples were stored at -30°C with no product and dried at 25°C and 50°C with no product, in Biomatrica DNAstable Plus or GenTegra DNA. We analyzed the samples after 0, 1, 2, 4, 8, 16, 32, and 64 weeks using the Nanodrop 1000 to determine the amount of DNA in each aliquot and by real-time PCR for the S. pneumoniae genes lytA and psaA. Using a 50°C storage temperature, we simulated 362 weeks of 25°C storage. The average amount of DNA in aliquots stored with a stabilizing matrix was 103%-116% of the original amount added to the tubes. This is similar to samples stored at -30°C (average 102%-121%). With one exception, samples stored with a stabilizing matrix had no change in lytA or psaA cycle threshold (Ct) value over time (Ct range ≤2.9), similar to samples stored at -30°C (Ct range ≤3.0). Samples stored at 25°C with no stabilizing matrix had Ct ranges of 2.2-5.1. DNAstable Plus and GenTegra DNA can protect dried bacterial DNA samples stored at room temperature with similar effectiveness as at -30°C. It is not effective to store bacterial DNA at room temperature without a stabilizing matrix.

  8. Ice-Sheet Dynamics and Millennial-Scale Climate Variability in the North Atlantic across the Middle Pleistocene Transition (Invited)

    NASA Astrophysics Data System (ADS)

    Hodell, D. A.; Nicholl, J.

    2013-12-01

    During the Middle Pleistocene Transition (MPT), the climate system evolved from a more linear response to insolation forcing in the '41-kyr world' to one that was decidedly non-linear in the '100-kyr world'. Smaller ice sheets in the early Pleistocene gave way to larger ice sheets in the late Pleistocene with an accompanying change in ice sheet dynamics. We studied Sites U1308 (49° 52.7'N, 24° 14.3'W; 3871 m) and U1304 (53° 3.4'N, 33° 31.8'W; 3024 m) in the North Atlantic to determine how ice sheet dynamics and millennial-scale climate variability evolved as glacial boundary conditions changed across the MPT. The frequency of ice-rafted detritus (IRD) in the North Atlantic was greater during glacial stages prior to 650 ka (MIS 16), reflecting more frequent crossing of an ice volume threshold when the climate system spent more time in the 'intermediate ice volume' window, resulting in persistent millennial scale variability. The rarity of Heinrich Events containing detrital carbonate and more frequent occurrence of IRD events prior to 650 ka may indicate the presence of 'low-slung, slippery ice sheets' that flowed more readily than their post-MPT counterparts (Bailey et al., 2010). Ice volume surpassed a critical threshold across the MPT that permitted ice sheets to survive boreal summer insolation maxima, thereby increasing ice volume and thickness, lengthening glacial cycles, and activating the dynamical processes responsible for Laurentide Ice Sheet instability in the region of Hudson Strait (i.e., Heinrich events). The excess ice volume during post-MPT glacial maxima provided a large, unstable reservoir of freshwater to be released to the North Atlantic during glacial terminations with the potential to perturb Atlantic Meridional Overtunring Circulation. We speculate that orbital- and millennial-scale variability co-evolved across the MPT and the interaction of processes on orbital and suborbital time scales gave rise to the changing patterns of glacial-interglacial cycles through the Quaternary. Bailey, I., Bolton, C.T., DeConto, R.M., Pollard, D., Schiebel, R. and Wilson, P.A. (2010) A low threshold for North Atlantic ice rafting from "low-slung slippery" late Pliocene ice sheets. Paleoceanography, 25, PA1212-[14pp]. (doi:10.1029/2009PA001736).

  9. MO-F-CAMPUS-J-05: Toward MRI-Only Radiotherapy: Novel Tissue Segmentation and Pseudo-CT Generation Techniques Based On T1 MRI Sequences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aouadi, S; McGarry, M; Hammoud, R

    Purpose: To develop and validate a 4 class tissue segmentation approach (air cavities, background, bone and soft-tissue) on T1 -weighted brain MRI and to create a pseudo-CT for MRI-only radiation therapy verification. Methods: Contrast-enhanced T1-weighted fast-spin-echo sequences (TR = 756ms, TE= 7.152ms), acquired on a 1.5T GE MRI-Simulator, are used.MRIs are firstly pre-processed to correct for non uniformity using the non parametric, non uniformity intensity normalization algorithm. Subsequently, a logarithmic inverse scaling log(1/image) is applied, prior to segmentation, to better differentiate bone and air from soft-tissues. Finally, the following method is enrolled to classify intensities into air cavities, background, bonemore » and soft-tissue:Thresholded region growing with seed points in image corners is applied to get a mask of Air+Bone+Background. The background is, afterward, separated by the scan-line filling algorithm. The air mask is extracted by morphological opening followed by a post-processing based on knowledge about air regions geometry. The remaining rough bone pre-segmentation is refined by applying 3D geodesic active contours; bone segmentation evolves by the sum of internal forces from contour geometry and external force derived from image gradient magnitude.Pseudo-CT is obtained by assigning −1000HU to air and background voxels, performing linear mapping of soft-tissue MR intensities in [-400HU, 200HU] and inverse linear mapping of bone MR intensities in [200HU, 1000HU]. Results: Three brain patients having registered MRI and CT are used for validation. CT intensities classification into 4 classes is performed by thresholding. Dice and misclassification errors are quantified. Correct classifications for soft-tissue, bone, and air are respectively 89.67%, 77.8%, and 64.5%. Dice indices are acceptable for bone (0.74) and soft-tissue (0.91) but low for air regions (0.48). Pseudo-CT produces DRRs with acceptable clinical visual agreement to CT-based DRR. Conclusion: The proposed approach makes it possible to use T1-weighted MRI to generate accurate pseudo-CT from 4-class segmentation.« less

  10. Enhancing robustness and immunization in geographical networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang Liang; Department of Physics, Lanzhou University, Lanzhou 730000; Yang Kongqing

    2007-03-15

    We find that different geographical structures of networks lead to varied percolation thresholds, although these networks may have similar abstract topological structures. Thus, strategies for enhancing robustness and immunization of a geographical network are proposed. Using the generating function formalism, we obtain an explicit form of the percolation threshold q{sub c} for networks containing arbitrary order cycles. For three-cycles, the dependence of q{sub c} on the clustering coefficients is ascertained. The analysis substantiates the validity of the strategies with analytical evidence.

  11. Chromosome Territories

    PubMed Central

    Cremer, Thomas; Cremer, Marion

    2010-01-01

    Chromosome territories (CTs) constitute a major feature of nuclear architecture. In a brief statement, the possible contribution of nuclear architecture studies to the field of epigenomics is considered, followed by a historical account of the CT concept and the final compelling experimental evidence of a territorial organization of chromosomes in all eukaryotes studied to date. Present knowledge of nonrandom CT arrangements, of the internal CT architecture, and of structural interactions with other CTs is provided as well as the dynamics of CT arrangements during cell cycle and postmitotic terminal differentiation. The article concludes with a discussion of open questions and new experimental strategies to answer them. PMID:20300217

  12. SU-E-J-252: A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, I; Ahmad, S; Alsbou, N

    Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embeddedmore » into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.« less

  13. Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study

    NASA Astrophysics Data System (ADS)

    Werner, René; Gauer, Tobias

    2015-03-01

    Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.

  14. Semi-automated segmentation of solid and GGO nodules in lung CT images using vessel-likelihood derived from local foreground structure

    NASA Astrophysics Data System (ADS)

    Yaguchi, Atsushi; Okazaki, Tomoya; Takeguchi, Tomoyuki; Matsumoto, Sumiaki; Ohno, Yoshiharu; Aoyagi, Kota; Yamagata, Hitoshi

    2015-03-01

    Reflecting global interest in lung cancer screening, considerable attention has been paid to automatic segmentation and volumetric measurement of lung nodules on CT. Ground glass opacity (GGO) nodules deserve special consideration in this context, since it has been reported that they are more likely to be malignant than solid nodules. However, due to relatively low contrast and indistinct boundaries of GGO nodules, segmentation is more difficult for GGO nodules compared with solid nodules. To overcome this difficulty, we propose a method for accurately segmenting not only solid nodules but also GGO nodules without prior information about nodule types. First, the histogram of CT values in pre-extracted lung regions is modeled by a Gaussian mixture model and a threshold value for including high-attenuation regions is computed. Second, after setting up a region of interest around the nodule seed point, foreground regions are extracted by using the threshold and quick-shift-based mode seeking. Finally, for separating vessels from the nodule, a vessel-likelihood map derived from elongatedness of foreground regions is computed, and a region growing scheme starting from the seed point is applied to the map with the aid of fast marching method. Experimental results using an anthropomorphic chest phantom showed that our method yielded generally lower volumetric measurement errors for both solid and GGO nodules compared with other methods reported in preceding studies conducted using similar technical settings. Also, our method allowed reasonable segmentation of GGO nodules in low-dose images and could be applied to clinical CT images including part-solid nodules.

  15. Lumbopelvic Core Stabilization Exercise and Pain Modulation Among Individuals with Chronic Nonspecific Low Back Pain.

    PubMed

    Paungmali, Aatit; Joseph, Leonard H; Sitilertpisan, Patraporn; Pirunsan, Ubon; Uthaikhup, Sureeporn

    2017-11-01

    Lumbopelvic stabilization training (LPST) may provide therapeutic benefits on pain modulation in chronic nonspecific low back pain conditions. This study aimed to examine the effects of LPST on pain threshold and pain intensity in comparison with the passive automated cycling intervention and control intervention among patients with chronic nonspecific low back pain. A within-subject, repeated-measures, crossover randomized controlled design was conducted among 25 participants (7 males and 18 females) with chronic nonspecific low back pain. All the participants received 3 different types of experimental interventions, which included LPST, the passive automated cycling intervention, and the control intervention randomly, with 48 hours between the sessions. The pressure pain threshold (PPT), hot-cold pain threshold, and pain intensity were estimated before and after the interventions. Repeated-measures analysis of variance showed that LPST provided therapeutic effects as it improved the PPT beyond the placebo and control interventions (P < 0.01). The pain intensity under the LPST condition was significantly better than that under the passive automated cycling intervention and controlled intervention (P < 0.001). Heat pain threshold under the LPST condition also showed a significant trend of improvement beyond the control (P < 0.05), but no significant effects on cold pain threshold were evident. Lumbopelvic stabilization training may provide therapeutic effects by inducing pain modulation through an improvement in the pain threshold and reduction in pain intensity. LPST may be considered as part of the management programs for treatment of chronic low back pain. © 2017 World Institute of Pain.

  16. The Rate of Return to Schooling and the Business Cycle: Additional Estimates.

    ERIC Educational Resources Information Center

    Kniesner, Thomas J.; And Others

    1980-01-01

    Illustrates that the business cycle does indeed disturb relative Black/White rates of return to schooling. Blacks fare relatively poorly in times of high unemployment. Data tables and formulas are presented to support the argument. (CT)

  17. SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahi-Anwar, M; Lo, P; Kim, H

    Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifiesmore » the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel component to automatically verify image acquisition parameters and automated adherence to specifications. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant support from: U01 CA181156.« less

  18. SU-C-BRA-02: Gradient Based Method of Target Delineation On PET/MR Image of Head and Neck Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dance, M; Chera, B; Falchook, A

    2015-06-15

    Purpose: Validate the consistency of a gradient-based segmentation tool to facilitate accurate delineation of PET/CT-based GTVs in head and neck cancers by comparing against hybrid PET/MR-derived GTV contours. Materials and Methods: A total of 18 head and neck target volumes (10 primary and 8 nodal) were retrospectively contoured using a gradient-based segmentation tool by two observers. Each observer independently contoured each target five times. Inter-observer variability was evaluated via absolute percent differences. Intra-observer variability was examined by percentage uncertainty. All target volumes were also contoured using the SUV percent threshold method. The thresholds were explored case by case so itsmore » derived volume matched with the gradient-based volume. Dice similarity coefficients (DSC) were calculated to determine overlap of PET/CT GTVs and PET/MR GTVs. Results: The Levene’s test showed there was no statistically significant difference of the variances between the observer’s gradient-derived contours. However, the absolute difference between the observer’s volumes was 10.83%, with a range from 0.39% up to 42.89%. PET-avid regions with qualitatively non-uniform shapes and intensity levels had a higher absolute percent difference near 25%, while regions with uniform shapes and intensity levels had an absolute percent difference of 2% between observers. The average percentage uncertainty between observers was 4.83% and 7%. As the volume of the gradient-derived contours increased, the SUV threshold percent needed to match the volume decreased. Dice coefficients showed good agreement of the PET/CT and PET/MR GTVs with an average DSC value across all volumes at 0.69. Conclusion: Gradient-based segmentation of PET volume showed good consistency in general but can vary considerably for non-uniform target shapes and intensity levels. PET/CT-derived GTV contours stemming from the gradient-based tool show good agreement with the anatomically and metabolically more accurate PET/MR-derived GTV contours, but tumor delineation accuracy can be further improved with the use PET/MR.« less

  19. A Size Effect on the Fatigue Crack Growth Rate Threshold of Alloy 718

    NASA Technical Reports Server (NTRS)

    Garr, K. R.; Hresko, G. C., III

    1998-01-01

    Fatigue crack growth rate (FCGR) tests were conducted on Alloy 718 in the solution annealed and aged condition at room temperature. In each test, the FCGR threshold was measured using the decreasing (Delta)K method. Initial testing was at two facilities, one of which used C(T) specimens with W = 127 mm. Previous data at the other facility had been obtained with specimens with W = 50.8 mm. A comparison of test results at R = 0.1 showed that the threshold for the 127 mm specimen was considerably higher than that of the 50.8 mm specimen. A check showed that this difference was not due to a heat-to-heat or lab-to-lab variation. Additional tests were conducted on specimens with W = 25.4 mm and at other R values. Data for the various specimens is presented along with parameters usually used to describe threshold behavior.

  20. Impact of radiotherapy and chemotherapy on biomarkers of oxidative DNA damage in lung cancer patients.

    PubMed

    Crohns, Marika; Saarelainen, Seppo; Erhola, Marina; Alho, Hannu; Kellokumpu-Lehtinen, Pirkko

    2009-07-01

    To assess oxidative damage to DNA during lung cancer (LC) treatments. Urinary levels of 8-oxoguanine (8-oxoGua) and levels of 8-oxo-2'-deoxyguanosine (8-oxodG) from urine and whole blood were determined in 36 non-cancer controls and 65 LC patients before any treatments. Samples were also obtained of LC patients during and after radiotherapy (RT, n=33) and chemotherapy (CT, n=16). Stage IV LC patients had higher urinary 8-oxoGua and 8-oxodG levels than patients with stage I-III disease (p=0.044 and p=0.034, respectively). Urinary 8-oxodG levels increased during the first week of RT (p<0.001). Nuclear 8-oxodG increased during RT and 3 months after start of RT. Nuclear 8-oxodG levels also rose between the first two CT cycles (p=0.043), and urinary 8-oxodG levels during the sixth CT cycle (p=0.009). Urinary DNA damage biomarker levels may be associated with LC stage. Both RT and CT increase the parameters of DNA oxidation.

  1. Radium-223 IN metastatic hormone-sensitive high-grade prostate cancer: initial experience.

    PubMed

    Osvaldo, García-Pérez Francisco; Salvador, Medina-Ornelas Sevastián; Zael, Santana-Ríos; Nora, Sobrevilla-Moreno

    2017-01-01

    Our study evaluates the feasibility of compassionate exemption of Radium-223 ( 223 Ra) treatment in metastatic hormone-sensitive high-grade prostate cancer (mHSHGPC) patients with concomitant androgen deprivation-therapy (ADT). Seven patients with mHSHGPC, were treated with six cycles of 223 Ra plus ADT. All patients had undergone to 18 F-NaF-PET/CT. A qualitative analyses of the 18 F-NaF-PET/CT was performed in conjunction with Alkaline Phosphatase (ALP), Lactate-dehydrogenase (LDH) and Prostatic-Specific Antigen (PSA) values. The mean of SUVmax values were used as a quantitative measure of tumoral burden. Changes in PSA, ALP, LDH from baseline were evaluated, and were defined as increase or decrease of at least 30%. Clinical response was achieved if there was pain reduction using visual analogic scale. Four patients showed a significant reduction in mean SUVmax after 3 cycles of 223 Ra, and one after 6 cycles. Patients who showed reductions in mean SUVmax after Ra-223 also showed reductions in PSA, ALP and LDH. Four weeks after the last cycle of 223 Ra all patients had decreased total PSA, ALP and LDH values ≥ 30% also significant improvement on pain. No progress disease was documented after 14 ± 4 weeks. We found slight to moderate decreases in neutrophils and hemoglobin in two patients. We concluded that 223 Ra plus ADT can be useful in mHSHGPC; the semi-quantitative 18 F-NaF-PET/CT as a method effective to monitor the treatment response. Due to concomitant administration of ADT, 18 F-NaF-PET/CT cannot differentiate whether the findings were due to androgen blockade or the 223 Ra; nevertheless, data supporting the efficacy of 223 Ra is the significant improvement on pain.

  2. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1981-03-03

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings aremore » inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.« less

  3. A coarse-to-fine approach for pericardial effusion localization and segmentation in chest CT scans

    NASA Astrophysics Data System (ADS)

    Liu, Jiamin; Chellamuthu, Karthik; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald M.

    2018-02-01

    Pericardial effusion on CT scans demonstrates very high shape and volume variability and very low contrast to adjacent structures. This inhibits traditional automated segmentation methods from achieving high accuracies. Deep neural networks have been widely used for image segmentation in CT scans. In this work, we present a two-stage method for pericardial effusion localization and segmentation. For the first step, we localize the pericardial area from the entire CT volume, providing a reliable bounding box for the more refined segmentation step. A coarse-scaled holistically-nested convolutional networks (HNN) model is trained on entire CT volume. The resulting HNN per-pixel probability maps are then threshold to produce a bounding box covering the pericardial area. For the second step, a fine-scaled HNN model is trained only on the bounding box region for effusion segmentation to reduce the background distraction. Quantitative evaluation is performed on a dataset of 25 CT scans of patient (1206 images) with pericardial effusion. The segmentation accuracy of our two-stage method, measured by Dice Similarity Coefficient (DSC), is 75.59+/-12.04%, which is significantly better than the segmentation accuracy (62.74+/-15.20%) of only using the coarse-scaled HNN model.

  4. Automatic co-segmentation of lung tumor based on random forest in PET-CT images

    NASA Astrophysics Data System (ADS)

    Jiang, Xueqing; Xiang, Dehui; Zhang, Bin; Zhu, Weifang; Shi, Fei; Chen, Xinjian

    2016-03-01

    In this paper, a fully automatic method is proposed to segment the lung tumor in clinical 3D PET-CT images. The proposed method effectively combines PET and CT information to make full use of the high contrast of PET images and superior spatial resolution of CT images. Our approach consists of three main parts: (1) initial segmentation, in which spines are removed in CT images and initial connected regions achieved by thresholding based segmentation in PET images; (2) coarse segmentation, in which monotonic downhill function is applied to rule out structures which have similar standardized uptake values (SUV) to the lung tumor but do not satisfy a monotonic property in PET images; (3) fine segmentation, random forests method is applied to accurately segment the lung tumor by extracting effective features from PET and CT images simultaneously. We validated our algorithm on a dataset which consists of 24 3D PET-CT images from different patients with non-small cell lung cancer (NSCLC). The average TPVF, FPVF and accuracy rate (ACC) were 83.65%, 0.05% and 99.93%, respectively. The correlation analysis shows our segmented lung tumor volumes has strong correlation ( average 0.985) with the ground truth 1 and ground truth 2 labeled by a clinical expert.

  5. Automated segmentation of hepatic vessel trees in non-contrast x-ray CT images

    NASA Astrophysics Data System (ADS)

    Kawajiri, Suguru; Zhou, Xiangrong; Zhang, Xuejin; Hara, Takeshi; Fujita, Hiroshi; Yokoyama, Ryujiro; Kondo, Hiroshi; Kanematsu, Masayuki; Hoshi, Hiroaki

    2007-03-01

    Hepatic vessel trees are the key structures in the liver. Knowledge of the hepatic vessel trees is important for liver surgery planning and hepatic disease diagnosis such as portal hypertension. However, hepatic vessels cannot be easily distinguished from other liver tissues in non-contrast CT images. Automated segmentation of hepatic vessels in non-contrast CT images is a challenging issue. In this paper, an approach for automated segmentation of hepatic vessels trees in non-contrast X-ray CT images is proposed. Enhancement of hepatic vessels is performed using two techniques: (1) histogram transformation based on a Gaussian window function; (2) multi-scale line filtering based on eigenvalues of Hessian matrix. After the enhancement of hepatic vessels, candidate of hepatic vessels are extracted by thresholding. Small connected regions of size less than 100 voxels are considered as false-positives and are removed from the process. This approach is applied to 20 cases of non-contrast CT images. Hepatic vessel trees segmented from the contrast-enhanced CT images of the same patient are used as the ground truth in evaluating the performance of the proposed segmentation method. Results show that the proposed method can enhance and segment the hepatic vessel regions in non-contrast CT images correctly.

  6. Menstrual cycle and the temporal discrimination threshold.

    PubMed

    Mc Govern, Eavan M; O'Connor, Emer; Beiser, Ines; Williams, Laura; Butler, John S; Quinlivan, Brendan; Narasimham, Shruti; Beck, Rebecca; Reilly, Richard B; O'Riordan, Sean; Hutchinson, Michael

    2017-02-01

    The temporal discrimination threshold (TDT) is a proposed pre-clinical biomarker (endophenotype) for adult onset isolated focal dystonia (AOIFD). Age- and sex-related effects on temporal discrimination demonstrate that women, before the age of 40 years, have faster temporal discrimination than men but their TDTs worsen with age at almost three times the rate of men. Thus after 40 years the TDT in women is progressively worse than in men. AOIFD is an increasingly female-predominant disorder after the age of 40; it is not clear whether this age-related sexually-dimorphic difference observed for both the TDT and sex ratio at disease onset in AOIFD is a hormonal or chromosomal effect. The aim of this study was to examine temporal discrimination at weekly intervals during two consecutive menstrual cycles in 14 healthy female volunteers to determine whether physiological hormonal changes affected temporal discrimination. We observed no significant differences in weekly temporal discrimination threshold values during the menstrual cycles and no significant correlation with the menstrual cycle stage. This observed stability of temporal discrimination during cyclical hormonal change raises interesting questions concerning the age-related sexually-dimorphic decline observed in temporal discrimination. Our findings pave the way for future studies exploring potential pathomechanisms for this age-related deterioration.

  7. Rapid Communication: MiR-92a as a housekeeping gene for analysis of bovine mastitis-related microRNA in milk.

    PubMed

    Lai, Y C; Fujikawa, T; Ando, T; Kitahara, G; Koiwa, M; Kubota, C; Miura, N

    2017-06-01

    Our aim was to identify a suitable microRNA housekeeping gene for real-time PCR analysis of bovine mastitis-related microRNA in milk. We identified , , and as housekeeping gene candidates on the basis of previous Solexa sequencing results. Threshold cycle (CT) values for , , and did not differ between milk from control cows and milk from mastitis-affected cows. NormFinder software identified as the most stable single housekeeping gene. We evaluated the suitability of the housekeeping gene candidates by using them to assess expression levels of the inflammation-related gene . Regardless of the housekeeping gene candidates used for normalization, relative expression levels of were significantly higher in mastitis-affected samples than in control samples. However, of all the housekeeping genes and gene combinations investigated, normalization with alone generated the difference in relative expression between mastitis-affected and control samples with the highest significance. These results suggest that is suitable for use as a housekeeping gene for analysis of bovine mastitis-related microRNA in milk.

  8. Gene transcription in sea otters (Enhydra lutris); development of a diagnostic tool for sea otter and ecosystem health

    USGS Publications Warehouse

    Bowen, Lizabeth; Miles, A. Keith; Murray, Michael; Haulena, Martin; Tuttle, Judy; van Bonn, William; Adams, Lance; Bodkin, James L.; Ballachey, Brenda E.; Estes, James A.; Tinker, M. Tim; Keister, Robin; Stott, Jeffrey L.

    2012-01-01

    Gene transcription analysis for diagnosing or monitoring wildlife health requires the ability to distinguish pathophysiological change from natural variation. Herein, we describe methodology for the development of quantitative real-time polymerase chain reaction (qPCR) assays to measure differential transcript levels of multiple immune function genes in the sea otter (Enhydra lutris); sea otter-specific qPCR primer sequences for the genes of interest are defined. We establish a ‘reference’ range of transcripts for each gene in a group of clinically healthy captive and free-ranging sea otters. The 10 genes of interest represent multiple physiological systems that play a role in immuno-modulation, inflammation, cell protection, tumour suppression, cellular stress response, xenobiotic metabolizing enzymes, antioxidant enzymes and cell–cell adhesion. The cycle threshold (CT) measures for most genes were normally distributed; the complement cytolysis inhibitor was the exception. The relative enumeration of multiple gene transcripts in simple peripheral blood samples expands the diagnostic capability currently available to assess the health of sea otters in situ and provides a better understanding of the state of their environment.

  9. Quantifying fracture geometry with X-ray tomography: Technique of Iterative Local Thresholding (TILT) for 3D image segmentation

    DOE PAGES

    Deng, Hang; Fitts, Jeffrey P.; Peters, Catherine A.

    2016-02-01

    This paper presents a new method—the Technique of Iterative Local Thresholding (TILT)—for processing 3D X-ray computed tomography (xCT) images for visualization and quantification of rock fractures. The TILT method includes the following advancements. First, custom masks are generated by a fracture-dilation procedure, which significantly amplifies the fracture signal on the intensity histogram used for local thresholding. Second, TILT is particularly well suited for fracture characterization in granular rocks because the multi-scale Hessian fracture (MHF) filter has been incorporated to distinguish fractures from pores in the rock matrix. Third, TILT wraps the thresholding and fracture isolation steps in an optimized iterativemore » routine for binary segmentation, minimizing human intervention and enabling automated processing of large 3D datasets. As an illustrative example, we applied TILT to 3D xCT images of reacted and unreacted fractured limestone cores. Other segmentation methods were also applied to provide insights regarding variability in image processing. The results show that TILT significantly enhanced separability of grayscale intensities, outperformed the other methods in automation, and was successful in isolating fractures from the porous rock matrix. Because the other methods are more likely to misclassify fracture edges as void and/or have limited capacity in distinguishing fractures from pores, those methods estimated larger fracture volumes (up to 80 %), surface areas (up to 60 %), and roughness (up to a factor of 2). In conclusion, these differences in fracture geometry would lead to significant disparities in hydraulic permeability predictions, as determined by 2D flow simulations.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diaz-Furlong, Alfonso; Diaz-Cruz, J. L.; Dual CP Institute of High Energy Physics

    We want to evaluate the three-body flavor-violating Higgs decays, i.e. h{sup 0}{yields}cW{sup -}b-bar, which could compete with the two-body decays h{sup 0}{yields}bb-bar, cc-bar, {tau}{sup +}{tau}{sup -}, below the threshold for the mode h{sup 0}{yields}ct-bar. Here we evaluate the mode h{sup 0}{yields}ct-bar; this mode would require m{sub h{sup 0}}>m{sub t}+m{sub c}, which may be in conflict with Electro-Weak precision tests. We work within the Randall-Sundrum set up, which is known to offer an alternative solution to the hierarchy problem.

  11. Automated detection system for pulmonary emphysema on 3D chest CT images

    NASA Astrophysics Data System (ADS)

    Hara, Takeshi; Yamamoto, Akira; Zhou, Xiangrong; Iwano, Shingo; Itoh, Shigeki; Fujita, Hiroshi; Ishigaki, Takeo

    2004-05-01

    An automatic extraction of pulmonary emphysema area on 3-D chest CT images was performed using an adaptive thresholding technique. We proposed a method to estimate the ratio of the emphysema area to the whole lung volume. We employed 32 cases (15 normal and 17 abnormal) which had been already diagnosed by radiologists prior to the study. The ratio in all the normal cases was less than 0.02, and in abnormal cases, it ranged from 0.01 to 0.26. The effectiveness of our approach was confirmed through the results of the present study.

  12. Gamma-ray blazar spectra with H.E.S.S. II mono analysis: The case of PKS 2155$-$304 and PG 1553+113

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdalla, H.; Abramowski, A.; Aharonian, F.

    In this paper, the addition of a 28 m Cherenkov telescope (CT5) to the H.E.S.S. array extended the experiment’s sensitivityto lower energies. The lowest energy threshold is obtained using monoscopic analysis of data taken with CT5, providing access to gamma-ray energies below 100 GeV for small zenith angle observations. Such an extension of the instrument’s energy range is particularly beneficial for studies of active galactic nuclei with soft spectra, as expected for those at a redshift ≥0.5. The high-frequency peaked BL Lac objects PKS 2155–304 (z = 0.116) and PG 1553+113 (0.43 < z < 0.58) are among the brightestmore » objects in the gamma-ray sky, both showing clear signatures of gamma-ray absorption at E > 100 GeV interpreted as being due to interactions with the extragalactic background light (EBL). Furthermore, the aims of this work are twofold: to demonstrate the monoscopic analysis of CT5 data with a low energy threshold, and to obtain accurate measurements of the spectral energy distributions (SED) of PKS 2155–304 and PG 1553+113 near their SED peaks at energies ≈100 GeV. Multiple observational campaigns of PKS 2155–304 and PG 1553+113 were conducted during 2013 and 2014 using the full H.E.S.S. II instrument (CT1–5). A monoscopic analysis of the data taken with the new CT5 telescope was developed along with an investigation into the systematic uncertainties on the spectral parameters which are derived from this analysis. As a result, using the data from CT5, the energy spectra of PKS 2155–304 and PG 1553+113 were reconstructed down to conservative threshold energies of 80 GeV for PKS 2155–304, which transits near zenith, and 110 GeV for the more northern PG 1553+113. The measured spectra, well fitted in both cases by a log-parabola spectral model (with a 5.0σ statistical preference for non-zero curvature for PKS 2155–304 and 4.5σ for PG 1553+113), were found consistent with spectra derived from contemporaneous Fermi-LAT data, indicating a sharp break in the observed spectra of both sources at E ≈ 100 GeV. When corrected for EBL absorption, the intrinsic H.E.S.S. II mono and Fermi-LAT spectrum of PKS 2155–304 was found to show significant curvature. For PG 1553+113, however, no significant detection of curvature in the intrinsic spectrum could be found within statistical and systematic uncertainties.« less

  13. Gamma-ray blazar spectra with H.E.S.S. II mono analysis: The case of PKS 2155$-$304 and PG 1553+113

    DOE PAGES

    Abdalla, H.; Abramowski, A.; Aharonian, F.; ...

    2017-04-05

    In this paper, the addition of a 28 m Cherenkov telescope (CT5) to the H.E.S.S. array extended the experiment’s sensitivityto lower energies. The lowest energy threshold is obtained using monoscopic analysis of data taken with CT5, providing access to gamma-ray energies below 100 GeV for small zenith angle observations. Such an extension of the instrument’s energy range is particularly beneficial for studies of active galactic nuclei with soft spectra, as expected for those at a redshift ≥0.5. The high-frequency peaked BL Lac objects PKS 2155–304 (z = 0.116) and PG 1553+113 (0.43 < z < 0.58) are among the brightestmore » objects in the gamma-ray sky, both showing clear signatures of gamma-ray absorption at E > 100 GeV interpreted as being due to interactions with the extragalactic background light (EBL). Furthermore, the aims of this work are twofold: to demonstrate the monoscopic analysis of CT5 data with a low energy threshold, and to obtain accurate measurements of the spectral energy distributions (SED) of PKS 2155–304 and PG 1553+113 near their SED peaks at energies ≈100 GeV. Multiple observational campaigns of PKS 2155–304 and PG 1553+113 were conducted during 2013 and 2014 using the full H.E.S.S. II instrument (CT1–5). A monoscopic analysis of the data taken with the new CT5 telescope was developed along with an investigation into the systematic uncertainties on the spectral parameters which are derived from this analysis. As a result, using the data from CT5, the energy spectra of PKS 2155–304 and PG 1553+113 were reconstructed down to conservative threshold energies of 80 GeV for PKS 2155–304, which transits near zenith, and 110 GeV for the more northern PG 1553+113. The measured spectra, well fitted in both cases by a log-parabola spectral model (with a 5.0σ statistical preference for non-zero curvature for PKS 2155–304 and 4.5σ for PG 1553+113), were found consistent with spectra derived from contemporaneous Fermi-LAT data, indicating a sharp break in the observed spectra of both sources at E ≈ 100 GeV. When corrected for EBL absorption, the intrinsic H.E.S.S. II mono and Fermi-LAT spectrum of PKS 2155–304 was found to show significant curvature. For PG 1553+113, however, no significant detection of curvature in the intrinsic spectrum could be found within statistical and systematic uncertainties.« less

  14. High Incidence of Preharvest Colonization of Huanglongbing-Symptomatic Citrus sinensis Fruit by Lasiodiplodia theobromae (Diplodia natalensis) and Exacerbation of Postharvest Fruit Decay by That Fungus

    PubMed Central

    Zhao, Wei; Bai, Jinhe; McCollum, Greg

    2014-01-01

    Huanglongbing (HLB), presumably caused by the bacterium “Candidatus Liberibacter asiaticus,” is a devastating citrus disease associated with excessive preharvest fruit drop. Lasiodiplodia theobromae (diplodia) is the causal organism of citrus stem end rot (SER). The pathogen infects citrus fruit under the calyx abscission zone (AZ-C) and is associated with cell wall hydrolytic enzymes similar to plant enzymes involved in abscission. By means of DNA sequencing, diplodia was found in “Ca. Liberibacter asiaticus”-positive juice from HLB-symptomatic fruit (S) but not in “Ca. Liberibacter asiaticus”-negative juice. Therefore, the incidence of diplodia in fruit tissues, the impact on HLB-related postharvest decay, and the implications for HLB-related preharvest fruit drop were investigated in Hamlin and Valencia oranges. Quantitative PCR results (qPCR) revealed a significantly (P < 0.001) greater incidence of diplodia in the AZ-C of HLB-symptomatic (S; “Ca. Liberibacter asiaticus” threshold cycle [CT] of <30) than in the AZ-C of in asymptomatic (AS; “Ca. Liberibacter asiaticus” CT of ≥30) fruit. In agreement with the qPCR results, 2 weeks after exposure to ethylene, the incidences of SER in S fruit were 66.7% (Hamlin) and 58.7% (Valencia), whereas for AS fruit the decay rates were 6.7% (Hamlin) and 5.3% (Valencia). Diplodia colonization of S fruit AZ-C was observed by scanning electron microscopy and confirmed by PCR test and morphology of conidia in isolates from the AZ-C after surface sterilization. Diplodia CT values were negatively correlated with ethylene production (R = −0.838 for Hamlin; R = −0.858 for Valencia) in S fruit, and positively correlated with fruit detachment force (R = 0.855 for Hamlin; R = 0.850 for Valencia), suggesting that diplodia colonization in AZ-C may exacerbate HLB-associated preharvest fruit drop. PMID:25344245

  15. CT-P6 compared with reference trastuzumab for HER2-positive breast cancer: a randomised, double-blind, active-controlled, phase 3 equivalence trial.

    PubMed

    Stebbing, Justin; Baranau, Yauheni; Baryash, Valeriy; Manikhas, Alexey; Moiseyenko, Vladimir; Dzagnidze, Giorgi; Zhavrid, Edvard; Boliukh, Dmytro; Stroyakovskii, Daniil; Pikiel, Joanna; Eniu, Alexandru; Komov, Dmitry; Morar-Bolba, Gabriela; Li, Rubi K; Rusyn, Andriy; Lee, Sang Joon; Lee, Sung Young; Esteva, Francisco J

    2017-07-01

    CT-P6 is a proposed biosimilar to reference trastuzumab. In this study, we aimed to establish equivalence of CT-P6 to reference trastuzumab in neoadjuvant treatment of HER2-positive early-stage breast cancer. In this randomised, double-blind, active-controlled, phase 3 equivalence trial, we recruited women aged 18 years or older with stage I-IIIa operable HER2-positive breast cancer from 112 centres in 23 countries. Inclusion criteria were an Eastern Cooperative Oncology Group performance status score of 0 or 1; a normal left ventricular ejection fraction of at least 55%; adequate bone marrow, hepatic, and renal function; at least one measureable lesion; and known oestrogen and progesterone receptor status. Exclusion criteria included bilateral breast cancer, previous breast cancer treatment, previous anthracycline treatment, and pregnancy or lactation. We randomly allocated patients 1:1 to receive neoadjuvant CT-P6 or reference trastuzumab intravenously (eight cycles, each lasting 3 weeks, for 24 weeks; 8 mg/kg on day 1 of cycle 1 and 6 mg/kg on day 1 of cycles 2-8) in conjunction with neoadjuvant docetaxel (75 mg/m 2 on day 1 of cycles 1-4) and FEC (fluorouracil [500 mg/m 2 ], epirubicin [75 mg/m 2 ], and cyclophosphamide [500 mg/m 2 ]; day 1 of cycles 5-8) therapy. We stratified randomisation by clinical stage, receptor status, and country and used permuted blocks. We did surgery within 3-6 weeks of the final neoadjuvant study drug dose, followed by an adjuvant treatment period of up to 1 year. We monitored long-term safety and efficacy for 3 years after the last patient was enrolled. Participants and investigators were masked to treatment until study completion. The primary efficacy endpoint, analysed in the per-protocol population, was pathological complete response, assessed via specimens obtained during surgery, analysed by masked central review of local histopathology reports. The equivalence margin was -0·15 to 0·15. This trial is registered with ClinicalTrials.gov, number NCT02162667, and is ongoing, but no longer recruiting. Between Aug 7, 2014, and May 6, 2016, we randomly allocated 549 patients (271 [49%] to CT-P6 vs 278 [51%] to reference trastuzumab). A similar proportion of patients achieved pathological complete response with CT-P6 (116 [46·8%; 95% CI 40·4-53·2] of 248 patients) and reference trastuzumab (129 [50·4%; 44·1-56·7] of 256 patients). The 95% CI of the estimated treatment outcome difference (-0·04% [95% CI -0·12 to 0·05]) was within the equivalence margin. 19 (7%) of 271 patients in the CT-P6 group reported serious treatment-emergent adverse events versus 22 (8%) of 278 in the reference trastuzumab group; frequent (occurring in more than one patient) serious adverse events were febrile neutropenia (four [1%] vs one [<1%]) and neutropenia (one [<1%] vs two [1%]). Grade 3 or worse treatment-related adverse events occurred in 17 (6%) of 271 patients in the CT-P6 group versus 23 (8%) of 278 in the reference trastuzumab group; the most frequently reported adverse event was neutropenia in ten (4%) versus 14 (5%). CT-P6 showed equivalent efficacy to reference trastuzumab and adverse events were similar. Availability of trastuzumab biosimilars could increase access to this targeted therapy for HER2-positive early-stage cancer. Celltrion Inc. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner.

    PubMed

    Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal

    2016-01-01

    The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.

  17. Cat-Scratch Disease: A Pitfall for Lymphoma Evaluation by FDG-PET/CT.

    PubMed

    Dubreuil, Julien; Dony, Arthur; Salles, Gilles; Traverse-Glehen, Alexandra; Giammarile, Francesco; Skanjeti, Andrea

    2017-02-01

    FDG-PET/CT is a standard of care in staging and response assessment of Hodgkin lymphoma. Hence, it is important to recognize pitfalls owing to the potential therapeutic impact. We report a case of a 29-year-old woman affected by stage III bulky Hodgkin lymphoma. The interim FDG-PET/CT showed a complete metabolic response. After three new cycles of chemotherapy, the patient showed fever and lymphadenopathy at clinic examination, PET/CT revealed several FDG uptakes at lymph nodes in inguinal and iliac region. Pathologic analyses, after biopsy and serologic examinations, led to the diagnosis of cat-scratch disease.

  18. Fuzzy pulmonary vessel segmentation in contrast enhanced CT data

    NASA Astrophysics Data System (ADS)

    Kaftan, Jens N.; Kiraly, Atilla P.; Bakai, Annemarie; Das, Marco; Novak, Carol L.; Aach, Til

    2008-03-01

    Pulmonary vascular tree segmentation has numerous applications in medical imaging and computer-aided diagnosis (CAD), including detection and visualization of pulmonary emboli (PE), improved lung nodule detection, and quantitative vessel analysis. We present a novel approach to pulmonary vessel segmentation based on a fuzzy segmentation concept, combining the strengths of both threshold and seed point based methods. The lungs of the original image are first segmented and a threshold-based approach identifies core vessel components with a high specificity. These components are then used to automatically identify reliable seed points for a fuzzy seed point based segmentation method, namely fuzzy connectedness. The output of the method consists of the probability of each voxel belonging to the vascular tree. Hence, our method provides the possibility to adjust the sensitivity/specificity of the segmentation result a posteriori according to application-specific requirements, through definition of a minimum vessel-probability required to classify a voxel as belonging to the vascular tree. The method has been evaluated on contrast-enhanced thoracic CT scans from clinical PE cases and demonstrates overall promising results. For quantitative validation we compare the segmentation results to randomly selected, semi-automatically segmented sub-volumes and present the resulting receiver operating characteristic (ROC) curves. Although we focus on contrast enhanced chest CT data, the method can be generalized to other regions of the body as well as to different imaging modalities.

  19. Simultaneous whole body 18F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with 18F-fluorodeoxyglucose positron emission tomography computed tomography

    PubMed Central

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-01-01

    AIM: To describe our preliminary experience with simultaneous whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. METHODS: This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated 18F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. RESULTS: A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student’s t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10-3 mm2/s. The 1.0 × 10-3 ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar’s test). CONCLUSION: These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients. PMID:27028112

  20. Simultaneous whole body (18)F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with (18)F-fluorodeoxyglucose positron emission tomography computed tomography.

    PubMed

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-03-28

    To describe our preliminary experience with simultaneous whole body (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated (18)F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student's t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10(-3) mm(2)/s. The 1.0 × 10(-3) ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar's test). These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients.

  1. Repeatability of quantitative parameters of 18F-fluoride PET/CT and biochemical tumour and specific bone remodelling markers in prostate cancer bone metastases.

    PubMed

    Wassberg, Cecilia; Lubberink, Mark; Sörensen, Jens; Johansson, Silvia

    2017-12-01

    18F-fluoride PET/CT exhibits high sensitivity to delineate and measure the extent of bone metastatic disease in patients with prostate cancer. 18F-fluoride PET/CT could potentially replace traditional bone scintigraphy in clinical routine and trials. However, more studies are needed to assess repeatability and biological uptake variation. The aim of this study was to perform test-retest analysis of quantitative PET-derived parameters and blood/serum bone turnover markers at the same time point. Ten patients with prostate cancer and verified bone metastases were prospectively included. All underwent two serial 18F-fluoride PET/CT at 1 h post-injection. Up to five dominant index lesions and whole-body 18F-fluoride skeletal tumour burden were recorded per patient. Lesion-based PET parameters were SUVmax, SUVmean and functional tumour volume applying a VOI with 50% threshold (FTV 50% ). The total skeletal tumour burden, total lesion 18F-fluoride (TLF), was calculated using a threshold of SUV of ≥15. Blood/serum biochemical bone turnover markers obtained at the time of each PET were PSA, ALP, S-osteocalcin, S-beta-CTx, 1CTP and BAP. A total of 47 index lesions and a range of 2-122 bone metastases per patient were evaluated. Median time between 18F-fluoride PET/CT was 7 days (range 6-8 days). Repeatability coefficients were for SUVmax 26%, SUVmean 24%, FTV 50% for index lesions 23% and total skeletal tumour burden (TLF) 35%. Biochemical bone marker repeatability coefficients were for PSA 19%, ALP 23%, S-osteocalcin 18%, S-beta-CTx 22%, 1CTP 18% and BAP 23%. Quantitative 18F-fluoride uptake and simultaneous biochemical bone markers measurements are reproducible for prostate cancer metastases and show similar magnitude in test-retest variation.

  2. Time efficient 124I-PET volumetry in benign thyroid disorders by automatic isocontour procedures: mathematic adjustment using manual contoured measurements in low-dose CT.

    PubMed

    Freesmeyer, Martin; Kühnel, Christian; Westphal, Julian G

    2015-01-01

    Benign thyroid diseases are widely common in western societies. However, the volumetry of the thyroid gland, especially when enlarged or abnormally formed, proves to be a challenge in clinical routine. The aim of this study was to develop a simple and rapid threshold-based isocontour extraction method for thyroid volumetry from (124)I-PET/CT data in patients scheduled for radioactive iodine therapy. PET/CT data from 45 patients were analysed 30 h after 1 MBq (124)I administration. Anatomical reference volume was calculated using manually contoured data from low-dose CT images of the neck (MC). In addition, we applied an automatic isocontour extraction method (IC0.2/1.0), with two different threshold values (0.2 and 1.0 kBq/ml), for volumetry of the PET data-set. IC0.2/1.0 shape data that showed significant variation from MC data were excluded. Subsequently, a mathematical correlation using a model of linear regression with multiple variables and step-wise elimination (mIC0.2/1.0), between IC0.2/1.0 and MC, was established. Data from 41 patients (IC0.2), and 32 patients (IC1.0) were analysed. The mathematically calculated volume, mIC, showed a median deviation from the reference (MC), of ±9 % (1-54 %) for mIC0.2 and of ±8.2 % (1-50 %) for mIC1.0 CONCLUSION: Contour extraction with both, mIC1.0 and mIC0.2 gave rapid and reliable results. However, mIC0.2 can be applied to significantly more patients (>90 %) and is, therefore, deemed to be more suitable for clinical routine, keeping in mind the potential advantages of using (124)I-PET/CT for the preparation of patients scheduled for radioactive iodine therapy.

  3. Characterization of Mode 1 and Mode 2 delamination growth and thresholds in graphite/peek composites

    NASA Technical Reports Server (NTRS)

    Martin, Roderick H.; Murri, Gretchen B.

    1988-01-01

    Composite materials often fail by delamination. The onset and growth of delamination in AS4/PEEK, a tough thermoplastic matrix composite, was characterized for mode 1 and mode 2 loadings, using the Double Cantilever Beam (DCB) and the End Notched Flexure (ENF) test specimens. Delamination growth per fatigue cycle, da/dN, was related to strain energy release rate, G, by means of a power law. However, the exponents of these power laws were too large for them to be adequately used as a life prediction tool. A small error in the estimated applied loads could lead to large errors in the delamination growth rates. Hence strain energy release rate thresholds, G sub th, below which no delamination would occur were also measured. Mode 1 and 2 threshold G values for no delamination growth were found by monitoring the number of cycles to delamination onset in the DCB and ENF specimens. The maximum applied G for which no delamination growth had occurred until at least 1,000,000 cycles was considered the threshold strain energy release rate. Comments are given on how testing effects, facial interference or delamination front damage, may invalidate the experimental determination of the constants in the expression.

  4. Characterization of Mode I and Mode II delamination growth and thresholds in AS4/PEEK composites

    NASA Technical Reports Server (NTRS)

    Martin, Roderick H.; Murri, Gretchen Bostaph

    1990-01-01

    Composite materials often fail by delamination. The onset and growth of delamination in AS4/PEEK, a tough thermoplastic matrix composite, was characterized for mode 1 and mode 2 loadings, using the Double Cantilever Beam (DCB) and the End Notched Flexure (ENF) test specimens. Delamination growth per fatigue cycle, da/dN, was related to strain energy release rate, G, by means of a power law. However, the exponents of these power laws were too large for them to be adequately used as a life prediction tool. A small error in the estimated applied loads could lead to large errors in the delamination growth rates. Hence strain energy release rate thresholds, G sub th, below which no delamination would occur were also measured. Mode 1 and 2 threshold G values for no delamination growth were found by monitoring the number of cycles to delamination onset in the DCB and ENF specimens. The maximum applied G for which no delamination growth had occurred until at least 1,000,000 cycles was considered the threshold strain energy release rate. Comments are given on how testing effects, facial interference or delamination front damage, may invalidate the experimental determination of the constants in the expression.

  5. Validated Automatic Brain Extraction of Head CT Images

    PubMed Central

    Muschelli, John; Ullman, Natalie L.; Mould, W. Andrew; Vespa, Paul; Hanley, Daniel F.; Crainiceanu, Ciprian M.

    2015-01-01

    Background X-ray Computed Tomography (CT) imaging of the brain is commonly used in diagnostic settings. Although CT scans are primarily used in clinical practice, they are increasingly used in research. A fundamental processing step in brain imaging research is brain extraction – the process of separating the brain tissue from all other tissues. Methods for brain extraction have either been 1) validated but not fully automated, or 2) fully automated and informally proposed, but never formally validated. Aim To systematically analyze and validate the performance of FSL's brain extraction tool (BET) on head CT images of patients with intracranial hemorrhage. This was done by comparing the manual gold standard with the results of several versions of automatic brain extraction and by estimating the reliability of automated segmentation of longitudinal scans. The effects of the choice of BET parameters and data smoothing is studied and reported. Methods All images were thresholded using a 0 – 100 Hounsfield units (HU) range. In one variant of the pipeline, data were smoothed using a 3-dimensional Gaussian kernel (σ = 1mm3) and re-thresholded to 0 – 100 HU; in the other, data were not smoothed. BET was applied using 1 of 3 fractional intensity (FI) thresholds: 0.01, 0.1, or 0.35 and any holes in the brain mask were filled. For validation against a manual segmentation, 36 images from patients with intracranial hemorrhage were selected from 19 different centers from the MISTIE (Minimally Invasive Surgery plus recombinant-tissue plasminogen activator for Intracerebral Evacuation) stroke trial. Intracranial masks of the brain were manually created by one expert CT reader. The resulting brain tissue masks were quantitatively compared to the manual segmentations using sensitivity, specificity, accuracy, and the Dice Similarity Index (DSI). Brain extraction performance across smoothing and FI thresholds was compared using the Wilcoxon signed-rank test. The intracranial volume (ICV) of each scan was estimated by multiplying the number of voxels in the brain mask by the dimensions of each voxel for that scan. From this, we calculated the ICV ratio comparing manual and automated segmentation: ICVautomatedICVmanual. To estimate the performance in a large number of scans, brain masks were generated from the 6 BET pipelines for 1095 longitudinal scans from 129 patients. Failure rates were estimated from visual inspection. ICV of each scan was estimated and and an intraclass correlation (ICC) was estimated using a one-way ANOVA. Results Smoothing images improves brain extraction results using BET for all measures except specificity (all p < 0.01, uncorrected), irrespective of the FI threshold. Using an FI of 0.01 or 0.1 performed better than 0.35. Thus, all reported results refer only to smoothed data using an FI of 0.01 or 0.1. Using an FI of 0.01 had a higher median sensitivity (0.9901) than an FI of 0.1 (0.9884, median difference: 0.0014, p < 0.001), accuracy (0.9971 vs. 0.9971; median difference: 0.0001, p < 0.001), and DSI (0.9895 vs. 0.9894; median difference: 0.0004, p < 0.001) and lower specificity (0.9981 vs. 0.9982; median difference: −0.0001, p < 0.001). These measures are all very high indicating that a range of FI values may produce visually indistinguishable brain extractions. Using smoothed data and an FI of 0.01, the mean (SD) ICV ratio was 1.002 (0.008); the mean being close to 1 indicates the ICV estimates are similar for automated and manual segmentation. In the 1095 longitudinal scans, this pipeline had a low failure rate (5.2%) and the ICC estimate was high (0.929, 95% CI: 0.91, 0.945) for successfully extracted brains. Conclusion BET performs well at brain extraction on thresholded, 1mm3 smoothed CT images with an FI of 0.01 or 0.1. Smoothing before applying BET is an important step not previously discussed in the literature. Analysis code is provided. PMID:25862260

  6. Enumeration of verocytotoxigenic Escherichia coli (VTEC) O157 and O26 in milk by quantitative PCR.

    PubMed

    Mancusi, Rocco; Trevisani, Marcello

    2014-08-01

    Quantitative real-time polymerase chain reaction (qPCR) can be a convenient alternative to the Most Probable Number (MPN) methods to count VTEC in milk. The number of VTEC is normally very low in milk; therefore with the aim of increasing the method sensitivity a qPCR protocol that relies on preliminary enrichment was developed. The growth pattern of six VTEC strains (serogroups O157 and O26) was studied using enrichment in Buffered Peptone Water (BPW) with or without acriflavine for 4-24h. Milk samples were inoculated with these strains over a five Log concentration range between 0.24-0.50 and 4.24-4.50 Log CFU/ml. DNA was extracted from the enriched samples in duplicate and each extract was analysed in duplicate by qPCR using pairs of primers specific for the serogroups O157 and O26. When samples were pre-enriched in BPW at 37°C for 8h, the relationship between threshold cycles (CT values) and VTEC Log numbers was linear over a five Log concentration range. The regression of PCR threshold cycle numbers on VTEC Log CFU/ml had a slope coefficient equal to -3.10 (R(2)=0.96) which is indicative of a 10-fold difference of the gene copy numbers between samples (with a 100 ± 10% PCR efficiency). The same 10-fold proportion used for inoculating the milk samples with VTEC was observed, therefore, also in the enriched samples at 8h. A comparison of the CT values of milk samples and controls revealed that the strains inoculated in milk grew with 3 Log increments in the 8h enrichment period. Regression lines that fitted the qPCR and MPN data revealed that the error of the qPCR estimates is lower than the error of the estimated MPN (r=0.982, R(2)=0.965 vs. r=0.967, R(2)=0.935). The growth rates of VTEC strains isolated from milk should be comparatively assessed before qPCR estimates based on the regression model are considered valid. Comparative assessment of the growth rates can be done using spectrophotometric measurements of standardized cultures of isolates and reference strains cultured in BPW at 37°C for 8h. The method developed for the serogroups O157 and O26 can be easily adapted to the other VTEC serogroups that are relevant for human health. The qPCR method is less laborious and faster than the standard MPN method and has been shown to be a good technique for quantifying VTEC in milk. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Studies in Above- and Below-Threshold Harmonics in Argon with an Infrared Femtosecond Laser

    NASA Astrophysics Data System (ADS)

    Chew, Andrew; Yin, Yanchun; Li, Jie; Ren, Xiaoming; Cunningham, Eric; Wu, Yi; Chang, Zenghu

    2016-05-01

    We investigate and compare the above- and below-threshold harmonics in Argon gas using our recently-developed 1 kHz, two-cycle (11.4 fs), 3mJ, and carrier-envelope-phase(CEP)-stable laser at 1.6 μm. Such ultraviolet pulses can serve as pump or probe for studying dynamics in atoms and molecules. Unlike high harmonics with photon energy well above the ionization potential, the mechanism for generating harmonics near the ionization threshold is still under intense investigation. Previous work by Chini et al. on below-threshold harmonics was done using a 0.8 μm few-cycle Ti:Sapphire spectrally-broadened source with energy up to 300 μJ. It has been predicted by theory that free-free transitions dominate the below threshold harmonic generation as the laser wavelength increase from near infrared to mid-infrared. We are therefore interested in investigating how using a longer wavelength laser might lead to changes to the behavior of below-threshold harmonics when we vary various parameters. We report the π-periodity CEP dependence and ellipticity dependence of the above- and below-threshold harmonics. This material was based on work supported by National Science Foundation (1068604), Army Research Office (W911NF-14-1-0383), Air Force Office of Scientific Research (FA9550-15-1-0037) and the DARPA PULSE program by a Grant from AMRDEC (W31P4Q1310017).

  8. A Knowledge Discovery Approach to Diagnosing Intracranial Hematomas on Brain CT: Recognition, Measurement and Classification

    NASA Astrophysics Data System (ADS)

    Liao, Chun-Chih; Xiao, Furen; Wong, Jau-Min; Chiang, I.-Jen

    Computed tomography (CT) of the brain is preferred study on neurological emergencies. Physicians use CT to diagnose various types of intracranial hematomas, including epidural, subdural and intracerebral hematomas according to their locations and shapes. We propose a novel method that can automatically diagnose intracranial hematomas by combining machine vision and knowledge discovery techniques. The skull on the CT slice is located and the depth of each intracranial pixel is labeled. After normalization of the pixel intensities by their depth, the hyperdense area of intracranial hematoma is segmented with multi-resolution thresholding and region-growing. We then apply C4.5 algorithm to construct a decision tree using the features of the segmented hematoma and the diagnoses made by physicians. The algorithm was evaluated on 48 pathological images treated in a single institute. The two discovered rules closely resemble those used by human experts, and are able to make correct diagnoses in all cases.

  9. A biochemical logic gate using an enzyme and its inhibitor. Part II: The logic gate.

    PubMed

    Sivan, Sarit; Tuchman, Samuel; Lotan, Noah

    2003-06-01

    Enzyme-Based Logic Gates (ENLOGs) are key components in bio-molecular systems for information processing. This report and the previous one in this series address the characterization of two bio-molecular switching elements, namely the alpha-chymotrypsin (alphaCT) derivative p-phenylazobenzoyl-alpha-chymotrypsin (PABalphaCT) and its inhibitor (proflavine), as well as their assembly into a logic gate. The experimental output of the proposed system is expressed in terms of enzymic activity and this was translated into logic output (i.e. "1" or "0") relative to a predetermined threshold value. We have found that an univalent link exists between the dominant isomers of PABalphaCT (cis or trans), the dominant form of either acridine (proflavine) or acridan and the logic output of the system. Thus, of all possible combinations, only the trans-PABalphaCT and the acridan lead to an enzymic activity that can be defined as logic output "1". The system operates under the rules of Boolean algebra and performs as an "AND" logic gate.

  10. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    PubMed

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  11. Hyoid bone development: An assessment of optimal CT scanner parameters and 3D volume rendering techniques

    PubMed Central

    Cotter, Meghan M.; Whyms, Brian J.; Kelly, Michael P.; Doherty, Benjamin M.; Gentry, Lindell R.; Bersu, Edward T.; Vorperian, Houri K.

    2015-01-01

    The hyoid bone anchors and supports the vocal tract. Its complex shape is best studied in three dimensions, but it is difficult to capture on computed tomography (CT) images and three-dimensional volume renderings. The goal of this study was to determine the optimal CT scanning and rendering parameters to accurately measure the growth and developmental anatomy of the hyoid and to determine whether it is feasible and necessary to use these parameters in the measurement of hyoids from in vivo CT scans. Direct linear and volumetric measurements of skeletonized hyoid bone specimens were compared to corresponding CT images to determine the most accurate scanning parameters and three-dimensional rendering techniques. A pilot study was undertaken using in vivo scans from a retrospective CT database to determine feasibility of quantifying hyoid growth. Scanning parameters and rendering technique affected accuracy of measurements. Most linear CT measurements were within 10% of direct measurements; however, volume was overestimated when CT scans were acquired with a slice thickness greater than 1.25 mm. Slice-by-slice thresholding of hyoid images decreased volume overestimation. The pilot study revealed that the linear measurements tested correlate with age. A fine-tuned rendering approach applied to small slice thickness CT scans produces the most accurate measurements of hyoid bones. However, linear measurements can be accurately assessed from in vivo CT scans at a larger slice thickness. Such findings imply that investigation into the growth and development of the hyoid bone, and the vocal tract as a whole, can now be performed using these techniques. PMID:25810349

  12. Hyoid Bone Development: An Assessment Of Optimal CT Scanner Parameters and Three-Dimensional Volume Rendering Techniques.

    PubMed

    Cotter, Meghan M; Whyms, Brian J; Kelly, Michael P; Doherty, Benjamin M; Gentry, Lindell R; Bersu, Edward T; Vorperian, Houri K

    2015-08-01

    The hyoid bone anchors and supports the vocal tract. Its complex shape is best studied in three dimensions, but it is difficult to capture on computed tomography (CT) images and three-dimensional volume renderings. The goal of this study was to determine the optimal CT scanning and rendering parameters to accurately measure the growth and developmental anatomy of the hyoid and to determine whether it is feasible and necessary to use these parameters in the measurement of hyoids from in vivo CT scans. Direct linear and volumetric measurements of skeletonized hyoid bone specimens were compared with corresponding CT images to determine the most accurate scanning parameters and three-dimensional rendering techniques. A pilot study was undertaken using in vivo scans from a retrospective CT database to determine feasibility of quantifying hyoid growth. Scanning parameters and rendering technique affected accuracy of measurements. Most linear CT measurements were within 10% of direct measurements; however, volume was overestimated when CT scans were acquired with a slice thickness greater than 1.25 mm. Slice-by-slice thresholding of hyoid images decreased volume overestimation. The pilot study revealed that the linear measurements tested correlate with age. A fine-tuned rendering approach applied to small slice thickness CT scans produces the most accurate measurements of hyoid bones. However, linear measurements can be accurately assessed from in vivo CT scans at a larger slice thickness. Such findings imply that investigation into the growth and development of the hyoid bone, and the vocal tract as a whole, can now be performed using these techniques. © 2015 Wiley Periodicals, Inc.

  13. Automated extraction method for the center line of spinal canal and its application to the spinal curvature quantification in torso X-ray CT images

    NASA Astrophysics Data System (ADS)

    Hayashi, Tatsuro; Zhou, Xiangrong; Chen, Huayue; Hara, Takeshi; Miyamoto, Kei; Kobayashi, Tatsunori; Yokoyama, Ryujiro; Kanematsu, Masayuki; Hoshi, Hiroaki; Fujita, Hiroshi

    2010-03-01

    X-ray CT images have been widely used in clinical routine in recent years. CT images scanned by a modern CT scanner can show the details of various organs and tissues. This means various organs and tissues can be simultaneously interpreted on CT images. However, CT image interpretation requires a lot of time and energy. Therefore, support for interpreting CT images based on image-processing techniques is expected. The interpretation of the spinal curvature is important for clinicians because spinal curvature is associated with various spinal disorders. We propose a quantification scheme of the spinal curvature based on the center line of spinal canal on CT images. The proposed scheme consists of four steps: (1) Automated extraction of the skeletal region based on CT number thresholding. (2) Automated extraction of the center line of spinal canal. (3) Generation of the median plane image of spine, which is reformatted based on the spinal canal. (4) Quantification of the spinal curvature. The proposed scheme was applied to 10 cases, and compared with the Cobb angle that is commonly used by clinicians. We found that a high-correlation (for the 95% confidence interval, lumbar lordosis: 0.81-0.99) between values obtained by the proposed (vector) method and Cobb angle. Also, the proposed method can provide the reproducible result (inter- and intra-observer variability: within 2°). These experimental results suggested a possibility that the proposed method was efficient for quantifying the spinal curvature on CT images.

  14. Stationarity of extreme bursts in the solar wind

    NASA Astrophysics Data System (ADS)

    Moloney, N. R.; Davidsen, J.

    2014-05-01

    Recent results have suggested that the statistics of bursts in the solar wind vary with solar cycle. Here, we show that this variation is basically absent if one considers extreme bursts. These are defined as threshold-exceeding events over the range of high thresholds for which their number decays as a power law. In particular, we find that the distribution of duration times and energies of extreme bursts in the solar wind ɛ parameter and similar observables are independent of the solar cycle and in this sense stationary, and show robust asymptotic power laws with exponents that are independent of the specific threshold. This is consistent with what has been observed for solar flares and, thus, provides evidence in favor of a link between solar flares and extreme bursts in the solar wind.

  15. Subsurface characterization with localized ensemble Kalman filter employing adaptive thresholding

    NASA Astrophysics Data System (ADS)

    Delijani, Ebrahim Biniaz; Pishvaie, Mahmoud Reza; Boozarjomehry, Ramin Bozorgmehry

    2014-07-01

    Ensemble Kalman filter, EnKF, as a Monte Carlo sequential data assimilation method has emerged promisingly for subsurface media characterization during past decade. Due to high computational cost of large ensemble size, EnKF is limited to small ensemble set in practice. This results in appearance of spurious correlation in covariance structure leading to incorrect or probable divergence of updated realizations. In this paper, a universal/adaptive thresholding method is presented to remove and/or mitigate spurious correlation problem in the forecast covariance matrix. This method is, then, extended to regularize Kalman gain directly. Four different thresholding functions have been considered to threshold forecast covariance and gain matrices. These include hard, soft, lasso and Smoothly Clipped Absolute Deviation (SCAD) functions. Three benchmarks are used to evaluate the performances of these methods. These benchmarks include a small 1D linear model and two 2D water flooding (in petroleum reservoirs) cases whose levels of heterogeneity/nonlinearity are different. It should be noted that beside the adaptive thresholding, the standard distance dependant localization and bootstrap Kalman gain are also implemented for comparison purposes. We assessed each setup with different ensemble sets to investigate the sensitivity of each method on ensemble size. The results indicate that thresholding of forecast covariance yields more reliable performance than Kalman gain. Among thresholding function, SCAD is more robust for both covariance and gain estimation. Our analyses emphasize that not all assimilation cycles do require thresholding and it should be performed wisely during the early assimilation cycles. The proposed scheme of adaptive thresholding outperforms other methods for subsurface characterization of underlying benchmarks.

  16. Concurrent chemotherapy and pelvic radiation therapy compared with pelvic radiation therapy alone as adjuvant therapy after radical surgery in high-risk early-stage cancer of the cervix.

    PubMed

    Peters, W A; Liu, P Y; Barrett, R J; Stock, R J; Monk, B J; Berek, J S; Souhami, L; Grigsby, P; Gordon, W; Alberts, D S

    2000-04-01

    To determine whether the addition of cisplatin-based chemotherapy (CT) to pelvic radiation therapy (RT) will improve the survival of early-stage, high-risk patients with cervical carcinoma. Patients with clinical stage IA(2), IB, and IIA carcinoma of the cervix, initially treated with radical hysterectomy and pelvic lymphadenectomy, and who had positive pelvic lymph nodes and/or positive margins and/or microscopic involvement of the parametrium were eligible for this study. Patients were randomized to receive RT or RT + CT. Patients in each group received 49.3 GY RT in 29 fractions to a standard pelvic field. Chemotherapy consisted of bolus cisplatin 70 mg/m(2) and a 96-hour infusion of fluorouracil 1,000 mg/m(2)/d every 3 weeks for four cycles, with the first and second cycles given concurrent to RT. Between 1991 and 1996, 268 patients were entered onto the study. Two hundred forty-three patients were assessable (127 RT + CT patients and 116 RT patients). Progression-free and overall survival are significantly improved in the patients receiving CT. The hazard ratios for progression-free survival and overall survival in the RT only arm versus the RT + CT arm are 2.01 (P =.003) and 1.96 (P =. 007), respectively. The projected progression-free survivals at 4 years is 63% with RT and 80% with RT + CT. The projected overall survival rate at 4 years is 71% with RT and 81% with RT + CT. Grades 3 and 4 hematologic and gastrointestinal toxicity were more frequent in the RT + CT group. The addition of concurrent cisplatin-based CT to RT significantly improves progression-free and overall survival for high-risk, early-stage patients who undergo radical hysterectomy and pelvic lymphadenectomy for carcinoma of the cervix.

  17. Mathematics of quantitative kinetic PCR and the application of standard curves.

    PubMed

    Rutledge, R G; Côté, C

    2003-08-15

    Fluorescent monitoring of DNA amplification is the basis of real-time PCR, from which target DNA concentration can be determined from the fractional cycle at which a threshold amount of amplicon DNA is produced. Absolute quantification can be achieved using a standard curve constructed by amplifying known amounts of target DNA. In this study, the mathematics of quantitative PCR are examined in detail, from which several fundamental aspects of the threshold method and the application of standard curves are illustrated. The construction of five replicate standard curves for two pairs of nested primers was used to examine the reproducibility and degree of quantitative variation using SYBER Green I fluorescence. Based upon this analysis the application of a single, well- constructed standard curve could provide an estimated precision of +/-6-21%, depending on the number of cycles required to reach threshold. A simplified method for absolute quantification is also proposed, in which quantitative scale is determined by DNA mass at threshold.

  18. Clinical experience with a computer-aided diagnosis system for automatic detection of pulmonary nodules at spiral CT of the chest

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2001-05-01

    The purpose of the study was to evaluate a computer aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Two radiologists in consensus reported 88 consecutive spiral CT examinations. All examinations were reviewed using a UNIX-based CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm was designed to detect nodules with at least 5 mm diameter. The results of automatic nodule detection were compared to the consensus reporting of two radiologists as gold standard. Additional CAD findings were regarded as nodules initially missed by the radiologists or as false positive results. A total of 153 nodules were detected with all modalities (diameter: 85 nodules <5mm, 63 nodules 5-9 mm, 5 nodules >= 10 mm). Reasons for failure of automatic nodule detection were assessed. Sensitivity of radiologists for nodules >=5 mm was 85%, sensitivity of CAD was 38%. For nodules >=5 mm without pleural contact sensitivity was 84% for radiologists at 45% for CAD. CAD detected 15 (10%) nodules not mentioned in the radiologist's report but representing real nodules, among them 10 (15%) nodules with a diameter $GREW5 mm. Reasons for nodules missed by CAD include: exclusion because of morphological features during region analysis (33%), nodule density below the detection threshold (26%), pleural contact (33%), segmentation errors (5%) and other reasons (2%). CAD improves detection of pulmonary nodules at spiral CT significantly and is a valuable second opinion in a clinical setting for lung cancer screening. Optimization of region analysis and an appropriate density threshold have a potential for further improvement of automatic nodule detection.

  19. Improved CT-based estimate of pulmonary gas trapping accounting for scanner and lung-volume variations in a multicenter asthmatic study.

    PubMed

    Choi, Sanghun; Hoffman, Eric A; Wenzel, Sally E; Castro, Mario; Lin, Ching-Long

    2014-09-15

    Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. Copyright © 2014 the American Physiological Society.

  20. Improved CT-based estimate of pulmonary gas trapping accounting for scanner and lung-volume variations in a multicenter asthmatic study

    PubMed Central

    Choi, Sanghun; Hoffman, Eric A.; Wenzel, Sally E.; Castro, Mario

    2014-01-01

    Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. PMID:25103972

  1. Economic Evaluations in the Diagnosis and Management of Traumatic Brain Injury: A Systematic Review and Analysis of Quality.

    PubMed

    Alali, Aziz S; Burton, Kirsteen; Fowler, Robert A; Naimark, David M J; Scales, Damon C; Mainprize, Todd G; Nathens, Avery B

    2015-07-01

    Economic evaluations provide a unique opportunity to identify the optimal strategies for the diagnosis and management of traumatic brain injury (TBI), for which uncertainty is common and the economic burden is substantial. The objective of this study was to systematically review and examine the quality of contemporary economic evaluations in the diagnosis and management of TBI. Two reviewers independently searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, NHS Economic Evaluation Database, Health Technology Assessment Database, EconLit, and the Tufts CEA Registry for comparative economic evaluations published from 2000 onward (last updated on August 30, 2013). Data on methods, results, and quality were abstracted in duplicate. The results were summarized quantitatively and qualitatively. Of 3539 citations, 24 economic evaluations met our inclusion criteria. Nine were cost-utility, five were cost-effectiveness, three were cost-minimization, and seven were cost-consequences analyses. Only six studies were of high quality. Current evidence from high-quality studies suggests the economic attractiveness of the following strategies: a low medical threshold for computed tomography (CT) scanning of asymptomatic infants with possible inflicted TBI, selective CT scanning of adults with mild TBI as per the Canadian CT Head Rule, management of severe TBI according to the Brain Trauma Foundation guidelines, management of TBI in dedicated neurocritical care units, and early transfer of patients with TBI with nonsurgical lesions to neuroscience centers. Threshold-guided CT scanning, adherence to Brain Trauma Foundation guidelines, and care for patients with TBI, including those with nonsurgical lesions, in specialized settings appear to be economically attractive strategies. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  2. Unenhanced CT imaging is highly sensitive to exclude pheochromocytoma: a multicenter study.

    PubMed

    Buitenwerf, Edward; Korteweg, Tijmen; Visser, Anneke; Haag, Charlotte M S C; Feelders, Richard A; Timmers, Henri J L M; Canu, Letizia; Haak, Harm R; Bisschop, Peter H L T; Eekhoff, Elisabeth M W; Corssmit, Eleonora P M; Krak, Nanda C; Rasenberg, Elise; van den Bergh, Janneke; Stoker, Jaap; Greuter, Marcel J W; Dullaart, Robin P F; Links, Thera P; Kerstens, Michiel N

    2018-05-01

    A substantial proportion of all pheochromocytomas is currently detected during the evaluation of an adrenal incidentaloma. Recently, it has been suggested that biochemical testing to rule out pheochromocytoma is unnecessary in case of an adrenal incidentaloma with an unenhanced attenuation value ≤10 Hounsfield Units (HU) at computed tomography (CT). We aimed to determine the sensitivity of the 10 HU threshold value to exclude a pheochromocytoma. Retrospective multicenter study with systematic reassessment of preoperative unenhanced CT scans performed in patients in whom a histopathologically proven pheochromocytoma had been diagnosed. Unenhanced attenuation values were determined independently by two experienced radiologists. Sensitivity of the 10 HU threshold was calculated, and interobserver consistency was assessed using the intraclass correlation coefficient (ICC). 214 patients were identified harboring a total number of 222 pheochromocytomas. Maximum tumor diameter was 51 (39-74) mm. The mean attenuation value within the region of interest was 36 ± 10 HU. Only one pheochromocytoma demonstrated an attenuation value ≤10 HU, resulting in a sensitivity of 99.6% (95% CI: 97.5-99.9). ICC was 0.81 (95% CI: 0.75-0.86) with a standard error of measurement of 7.3 HU between observers. The likelihood of a pheochromocytoma with an unenhanced attenuation value ≤10 HU on CT is very low. The interobserver consistency in attenuation measurement is excellent. Our study supports the recommendation that in patients with an adrenal incidentaloma biochemical testing for ruling out pheochromocytoma is only indicated in adrenal tumors with an unenhanced attenuation value >10 HU. © 2018 European Society of Endocrinology.

  3. 718F-FDG PET/CT metabolic tumor parameters and radiomics features in aggressive non-Hodgkin's lymphoma as predictors of treatment outcome and survival.

    PubMed

    Parvez, Aatif; Tau, Noam; Hussey, Douglas; Maganti, Manjula; Metser, Ur

    2018-05-12

    To determine whether metabolic tumor parameters and radiomic features extracted from 18 F-FDG PET/CT (PET) can predict response to therapy and outcome in patients with aggressive B-cell lymphoma. This institutional ethics board-approved retrospective study included 82 patients undergoing PET for aggressive B-cell lymphoma staging. Whole-body metabolic tumor volume (MTV) using various thresholds and tumor radiomic features were assessed on representative tumor sites. The extracted features were correlated with treatment response, disease-free survival (DFS) and overall survival (OS). At the end of therapy, 66 patients (80.5%) had shown complete response to therapy. The parameters correlating with response to therapy were bulky disease > 6 cm at baseline (p = 0.026), absence of a residual mass > 1.5 cm at the end of therapy CT (p = 0.028) and whole-body MTV with best performance using an SUV threshold of 3 and 6 (p = 0.015 and 0.009, respectively). None of the tumor texture features were predictive of first-line therapy response, while a few of them including GLNU correlated with disease-free survival (p = 0.013) and kurtosis correlated with overall survival (p = 0.035). Whole-body MTV correlates with response to therapy in patient with aggressive B-cell lymphoma. Tumor texture features could not predict therapy response, although several features correlated with the presence of a residual mass at the end of therapy CT and others correlated with disease-free and overall survival. These parameters should be prospectively validated in a larger cohort to confirm clinical prognostication.

  4. Development and Validation of the Suprathreshold Stochastic Resonance-Based Image Processing Method for the Detection of Abdomino-pelvic Tumor on PET/CT Scans.

    PubMed

    Saroha, Kartik; Pandey, Anil Kumar; Sharma, Param Dev; Behera, Abhishek; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    The detection of abdomino-pelvic tumors embedded in or nearby radioactive urine containing 18F-FDG activity is a challenging task on PET/CT scan. In this study, we propose and validate the suprathreshold stochastic resonance-based image processing method for the detection of these tumors. The method consists of the addition of noise to the input image, and then thresholding it that creates one frame of intermediate image. One hundred such frames were generated and averaged to get the final image. The method was implemented using MATLAB R2013b on a personal computer. Noisy image was generated using random Poisson variates corresponding to each pixel of the input image. In order to verify the method, 30 sets of pre-diuretic and its corresponding post-diuretic PET/CT scan images (25 tumor images and 5 control images with no tumor) were included. For each sets of pre-diuretic image (input image), 26 images (at threshold values equal to mean counts multiplied by a constant factor ranging from 1.0 to 2.6 with increment step of 0.1) were created and visually inspected, and the image that most closely matched with the gold standard (corresponding post-diuretic image) was selected as the final output image. These images were further evaluated by two nuclear medicine physicians. In 22 out of 25 images, tumor was successfully detected. In five control images, no false positives were reported. Thus, the empirical probability of detection of abdomino-pelvic tumors evaluates to 0.88. The proposed method was able to detect abdomino-pelvic tumors on pre-diuretic PET/CT scan with a high probability of success and no false positives.

  5. High-permeability region size on perfusion CT predicts hemorrhagic transformation after intravenous thrombolysis in stroke

    PubMed Central

    Puig, Josep; Blasco, Gerard; Daunis-i-Estadella, Pepus; van Eendendburg, Cecile; Carrillo-García, María; Aboud, Carlos; Hernández-Pérez, María; Serena, Joaquín; Biarnés, Carles; Nael, Kambiz; Liebeskind, David S.; Thomalla, Götz; Menon, Bijoy K.; Demchuk, Andrew; Wintermark, Max; Pedraza, Salvador

    2017-01-01

    Objective Blood-brain barrier (BBB) permeability has been proposed as a predictor of hemorrhagic transformation (HT) after tissue plasminogen activator (tPA) administration; however, the reliability of perfusion computed tomography (PCT) permeability imaging for predicting HT is uncertain. We aimed to determine the performance of high-permeability region size on PCT (HPrs-PCT) in predicting HT after intravenous tPA administration in patients with acute stroke. Methods We performed a multimodal CT protocol (non-contrast CT, PCT, CT angiography) to prospectively study patients with middle cerebral artery occlusion treated with tPA within 4.5 hours of symptom onset. HT was graded at 24 hours using the European-Australasian Acute Stroke Study II criteria. ROC curves selected optimal volume threshold, and multivariate logistic regression analysis identified predictors of HT. Results The study included 156 patients (50% male, median age 75.5 years). Thirty-seven (23,7%) developed HT [12 (7,7%), parenchymal hematoma type 2 (PH-2)]. At admission, patients with HT had lower platelet values, higher NIHSS scores, increased ischemic lesion volumes, larger HPrs-PCT, and poorer collateral status. The negative predictive value of HPrs-PCT at a threshold of 7mL/100g/min was 0.84 for HT and 0.93 for PH-2. The multiple regression analysis selected HPrs-PCT at 7mL/100g/min combined with platelets and baseline NIHSS score as the best model for predicting HT (AUC 0.77). HPrs-PCT at 7mL/100g/min was the only independent predictor of PH-2 (OR 1, AUC 0.68, p = 0.045). Conclusions HPrs-PCT can help predict HT after tPA, and is particularly useful in identifying patients at low risk of developing HT. PMID:29182658

  6. Pulmonary airways tree segmentation from CT examinations using adaptive volume of interest

    NASA Astrophysics Data System (ADS)

    Park, Sang Cheol; Kim, Won Pil; Zheng, Bin; Leader, Joseph K.; Pu, Jiantao; Tan, Jun; Gur, David

    2009-02-01

    Airways tree segmentation is an important step in quantitatively assessing the severity of and changes in several lung diseases such as chronic obstructive pulmonary disease (COPD), asthma, and cystic fibrosis. It can also be used in guiding bronchoscopy. The purpose of this study is to develop an automated scheme for segmenting the airways tree structure depicted on chest CT examinations. After lung volume segmentation, the scheme defines the first cylinder-like volume of interest (VOI) using a series of images depicting the trachea. The scheme then iteratively defines and adds subsequent VOIs using a region growing algorithm combined with adaptively determined thresholds in order to trace possible sections of airways located inside the combined VOI in question. The airway tree segmentation process is automatically terminated after the scheme assesses all defined VOIs in the iteratively assembled VOI list. In this preliminary study, ten CT examinations with 1.25mm section thickness and two different CT image reconstruction kernels ("bone" and "standard") were selected and used to test the proposed airways tree segmentation scheme. The experiment results showed that (1) adopting this approach affectively prevented the scheme from infiltrating into the parenchyma, (2) the proposed method reasonably accurately segmented the airways trees with lower false positive identification rate as compared with other previously reported schemes that are based on 2-D image segmentation and data analyses, and (3) the proposed adaptive, iterative threshold selection method for the region growing step in each identified VOI enables the scheme to segment the airways trees reliably to the 4th generation in this limited dataset with successful segmentation up to the 5th generation in a fraction of the airways tree branches.

  7. In vivo assessment of the gastric mucosal tolerance dose after single fraction, small volume irradiation of liver malignancies by computed tomography-guided, high-dose-rate brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Streitparth, Florian; Pech, Maciej; Boehmig, Michael

    2006-08-01

    Purpose: The aim of this study was to assess the tolerance dose of gastric mucosa for single-fraction computed tomography (CT)-guided, high-dose-rate (HDR) brachytherapy of liver malignancies. Methods and Materials: A total of 33 patients treated by CT-guided HDR brachytherapy of liver malignancies in segments II and/or III were included. Dose planning was performed upon a three-dimensional CT data set acquired after percutaneous applicator positioning. All patients received gastric protection post-treatment. For further analysis, the contours of the gastric wall were defined in every CT slice using Brachyvision Software. Dose-volume histograms were calculated for each treatment and correlated with clinical datamore » derived from questionnaires assessing Common Toxicity Criteria (CTC). All patients presenting symptoms of upper GI toxicity were examined endoscopically. Results: Summarizing all patients the minimum dose applied to 1 ml of the gastric wall (D{sub 1ml}) ranged from 6.3 to 34.2 Gy; median, 14.3 Gy. Toxicity was present in 18 patients (55%). We found nausea in 16 (69%), emesis in 9 (27%), cramping in 13 (39%), weight loss in 12 (36%), gastritis in 4 (12%), and ulceration in 5 patients (15%). We found a threshold dose D{sub 1ml} of 11 Gy for general gastric toxicity and 15.5 Gy for gastric ulceration verified by an univariate analysis (p = 0.01). Conclusions: For a single fraction, small volume irradiation we found in the upper abdomen a threshold dose D{sub 1ml} of 15.5 Gy for the clinical endpoint ulceration of the gastric mucosa. This in vivo assessment is in accordance with previously published tolerance data.« less

  8. Genetic Alterations in Colorectal Cancer Have Different Patterns on 18F-FDG PET/CT.

    PubMed

    Chen, Shang-Wen; Lin, Chien-Yu; Ho, Cheng-Man; Chang, Ya-Sian; Yang, Shu-Fen; Kao, Chia-Hung; Chang, Jan-Gowth

    2015-08-01

    The aim of this study was to understand the association between various genetic mutation and (18)F-FDG PET-related parameters in patients with colorectal cancer (CRC). One hundred three CRC patients who had undergone preoperative PET/CTs were included in this study. Several PET/CT-related parameters, including SUV(max), and various thresholds of metabolic tumor volume, total lesion glycolysis, and PET/CT-based tumor width (TW) were measured. Using high-resolution melting methods for genetic mutation analysis, tumor- and PET/CT-related parameters were correlated with various genetic alterations including TP53, KRAS, APC, BRAF, and PIK3CA. Mann-Whitney U test and logistic regression analysis were carried out for this analysis. Genetic alterations in TP53, KRAS, and APC were found in 41 (40%), 34 (33%), and 27 (26%) of tumors, respectively. PIK3CA and BRAF were exhibited by 5 and 4 of the patients with CRC. TP53 mutants exhibited higher SUV(max). The odds ratio was 1.28 (P = 0.04; 95% confidence interval, 1.01-1.61). Tumors with a mutated KRAS had an increased accumulation of FDG using a 40% threshold level for maximal uptake of TW (TW(40%)), whereas the odds ratio was 1.15 (P = 0.001; 95% confidence interval, 1.06-1.24). The accuracy of SUV(max) greater than 10 in predicting TP53 mutation was 60%, whereas that for TW(40%) for KRAS was 61%. Increased SUV(max) and TW(40%) were associated in CRC tumors with TP53 and KRAS mutations, respectively. Further studies are required because of the low predictive accuracy.

  9. Expression of CCK Receptors in Carcinoma Gallbladder and Cholelithiasis: A Pilot Study.

    PubMed

    Faridi, Mohammad Shazib; Jaiswal, Mahabir Saran Das; Goel, Sudhir K

    2015-07-01

    Gastrin and cholecystokinin (CCK) receptors are trophic for various gastrointestinal malignancies. Their role in gallbladder cancer has not been widely studied. To identify expression of CCK-A and CCK-B receptors in the tissue and blood of patients suffering from carcinoma (CA) gallbladder and gallstone disease and to compare expression of CCK A and B receptors in the gall bladder tissue and blood of healthy individuals and patients of CA gallbladder, and gallstone diseases. Forty nine subjects of both genders were recruited, comprising of 22 patients of CA gall bladder, 19 cases of cholelithiasis and, 8 normal gallbladders obtained from patients operated for trauma of the biliary system or Whipple's procedure. RNA extraction and cDNA formation for CCK-A and CCK-B receptors were carried out. Real Time PCR was performed on cDNA and threshold cycle (Ct) value of each sample was obtained and ΔCt was calculated. Chi-square test for comparing two groups and ANOVA test for comparing multiple groups were applied and if p<0.05 then Dunnett-C test was performed. Both CCK-A and CCK-B receptors were expressed irrespective of its origin in all tissues and blood samples studied; be it normal, Cholelithiasis or CA gallbladder and there was no difference among them (p>0.05). This preliminary study showed higher expression of CCK-A receptors in patients of cholelithiasis and decreased expression of CCK-A receptors in patients of CA gallbladder as compared to normal gallbladder although it did not rise to statistical significance.

  10. Expression of CCK Receptors in Carcinoma Gallbladder and Cholelithiasis: A Pilot Study

    PubMed Central

    Jaiswal, Mahabir Saran Das; Goel, Sudhir K.

    2015-01-01

    Background: Gastrin and cholecystokinin (CCK) receptors are trophic for various gastrointestinal malignancies. Their role in gallbladder cancer has not been widely studied. Objectives: To identify expression of CCK-A and CCK-B receptors in the tissue and blood of patients suffering from carcinoma (CA) gallbladder and gallstone disease and to compare expression of CCK A and B receptors in the gall bladder tissue and blood of healthy individuals and patients of CA gallbladder, and gallstone diseases. Materials and Methods: Forty nine subjects of both genders were recruited, comprising of 22 patients of CA gall bladder, 19 cases of cholelithiasis and, 8 normal gallbladders obtained from patients operated for trauma of the biliary system or Whipple’s procedure. RNA extraction and cDNA formation for CCK-A and CCK-B receptors were carried out. Real Time PCR was performed on cDNA and threshold cycle (Ct) value of each sample was obtained and ΔCt was calculated. Chi-square test for comparing two groups and ANOVA test for comparing multiple groups were applied and if p<0.05 then Dunnett-C test was performed. Observation and Results: Both CCK-A and CCK-B receptors were expressed irrespective of its origin in all tissues and blood samples studied; be it normal, Cholelithiasis or CA gallbladder and there was no difference among them (p>0.05). Conclusion: This preliminary study showed higher expression of CCK-A receptors in patients of cholelithiasis and decreased expression of CCK-A receptors in patients of CA gallbladder as compared to normal gallbladder although it did not rise to statistical significance. PMID:26393162

  11. Comparison between Awake Endoscopy and Computed Tomography to Define Lingual Tonsil Hypertrophy.

    PubMed

    Tang, Jessica A; Gorelick, Gleb; Friedman, Michael

    2017-11-01

    Objectives To analyze correlations between endoscopic lingual tonsil grade (LTG) by the Friedman Lingual Tonsil Hypertrophy grading system and computed tomography (CT) measurements of lingual tonsil thickness (LTT). Study Design Retrospective chart review. Setting Single-center database, September 2016 to April 2017. Subjects and Methods Patients who received CT covering base of tongue and endoscopic LTG were included. LTT was measured on axial and sagittal CT. LTT measurements were compared against endoscopic LTG. One-way analysis of variance with Tukey's post hoc adjustment for multiple comparisons was performed. Results Seventy-five charts were included for a total of 150 LTT measurements. Axial CT measurements of LTG 1 and LTG 2 were each significantly different from LTG 3 ( P < .001 for both), and LTG 1 and LTG 2 also differed significantly ( P = .010). Mean sagittal CT measurements were significantly different between LTG 1 and LTG 3 ( P < .001) and between LTG 2 and LTG 3 ( P = .002) but not between LTG 1 and LTG 2 ( P = .186). Those without lingual tonsil hypertrophy had a mean axial CT thickness of 6.45 ± 1.39 mm and mean sagittal CT thickness of 6.58 ± 1.53 mm, which was significantly different from both the mean axial CT thickness of 8.48 ± 1.52 mm and the mean sagittal CT thickness of 8.07 ± 1.16 mm in the LTG 3 group ( P < .001 for both). Threshold analysis showed a potential cutoff of approximately 7.5 mm on axial and sagittal CT for defining clinically significant lingual tonsil hypertrophy. Conclusion Awake endoscopy grading of lingual tonsil hypertrophy is a subjective measurement that seems to correlate with objective CT measurements. LTT measurements of LTG 1 and LTG 2 on awake endoscopy differed significantly from LTG 3.

  12. The mobile hospital technology industry: focus on the computerized tomography scanner.

    PubMed

    Hartley, D; Moscovice, I

    1996-01-01

    This study of firms offering mobile hospital technology to rural hospitals in eight northwestern states found that several permanently parked computerized tomography (CT) units were found where mobile routes had atrophied due to the purchase of fixed units by former mobile CT hospital clients. Based on a criterion of 140 scans per month per unit as a threshold of profitable production, units owned by larger firms (those that operate five or more units) were more likely to be profitable than units owned by smaller firms (71% versus 20%, P = 0.03). A substantial number of rural hospitals lose money on mobile CT due to low Medicare reimbursement. In some areas, mobile hospital technology is a highly competitive industry. Evidence was found that several firms compete in some geographic areas and that some firms have lost hospital clients to competing vendors.

  13. Robust segmentation of trabecular bone for in vivo CT imaging using anisotropic diffusion and multi-scale morphological reconstruction

    NASA Astrophysics Data System (ADS)

    Chen, Cheng; Jin, Dakai; Zhang, Xiaoliu; Levy, Steven M.; Saha, Punam K.

    2017-03-01

    Osteoporosis is associated with an increased risk of low-trauma fractures. Segmentation of trabecular bone (TB) is essential to assess TB microstructure, which is a key determinant of bone strength and fracture risk. Here, we present a new method for TB segmentation for in vivo CT imaging. The method uses Hessian matrix-guided anisotropic diffusion to improve local separability of trabecular structures, followed by a new multi-scale morphological reconstruction algorithm for TB segmentation. High sensitivity (0.93), specificity (0.93), and accuracy (0.92) were observed for the new method based on regional manual thresholding on in vivo CT images. Mechanical tests have shown that TB segmentation using the new method improved the ability of derived TB spacing measure for predicting actual bone strength (R2=0.83).

  14. Cycling Power Outputs Predict Functional Threshold Power And Maximum Oxygen Uptake.

    PubMed

    Denham, Joshua; Scott-Hamilton, John; Hagstrom, Amanda D; Gray, Adrian J

    2017-09-11

    Functional threshold power (FTP) has emerged as a correlate of lactate threshold and is commonly assessed by recreational and professional cyclists for tailored exercise programing. To identify whether results from traditional aerobic and anaerobic cycling tests could predict FTP and V˙ O2max, we analysed the association between estimated FTP, maximum oxygen uptake (V˙ O2max [mlkgmin]) and power outputs obtained from a maximal cycle ergometry cardiopulmonary exercise test (CPET) and a 30-s Wingate test in a heterogeneous cohort of cycle-trained and untrained individuals (N=40, mean±SD; age: 32.6±10.6 y; relative V˙ O2max: 46.8±9.1 mlkgmin). The accuracy and sensitivity of the prediction equations was also assessed in young men (N=11) before and after a 6-wk sprint interval training intervention.Moderate to strong positive correlations were observed between FTP, relative V˙ O2max and power outputs achieved during incremental and 30-s Wingate cycling tests (r=.39-.965, all P<.05). While maximum power achieved during incremental cycle testing (Pmax) and relative V˙ O2max were predictors of FTP (r =.93), age and FTP (Wkg) estimated relative V˙ O2max (r=.80). Our findings confirm that FTP predominantly relies on aerobic metabolism and indicate both prediction models are sensitive enough to detect meaningful exercise-induced changes in FTP and V˙ O2max. Thus, coaches should consider limiting the time and load demands placed on athletes by conducting a maximal cycle ergometry CPET to estimate FTP. Additionally, a 20-min FTP test is a convenient method to assess V˙ O2max and is particularly relevant for exercise professionals without access to expensive CPET equipment.

  15. Evaluation of thresholding techniques for segmenting scaffold images in tissue engineering

    NASA Astrophysics Data System (ADS)

    Rajagopalan, Srinivasan; Yaszemski, Michael J.; Robb, Richard A.

    2004-05-01

    Tissue engineering attempts to address the ever widening gap between the demand and supply of organ and tissue transplants using natural and biomimetic scaffolds. The regeneration of specific tissues aided by synthetic materials is dependent on the structural and morphometric properties of the scaffold. These properties can be derived non-destructively using quantitative analysis of high resolution microCT scans of scaffolds. Thresholding of the scanned images into polymeric and porous phase is central to the outcome of the subsequent structural and morphometric analysis. Visual thresholding of scaffolds produced using stochastic processes is inaccurate. Depending on the algorithmic assumptions made, automatic thresholding might also be inaccurate. Hence there is a need to analyze the performance of different techniques and propose alternate ones, if needed. This paper provides a quantitative comparison of different thresholding techniques for segmenting scaffold images. The thresholding algorithms examined include those that exploit spatial information, locally adaptive characteristics, histogram entropy information, histogram shape information, and clustering of gray-level information. The performance of different techniques was evaluated using established criteria, including misclassification error, edge mismatch, relative foreground error, and region non-uniformity. Algorithms that exploit local image characteristics seem to perform much better than those using global information.

  16. An alternative method for quantifying coronary artery calcification: the multi-ethnic study of atherosclerosis (MESA).

    PubMed

    Liang, C Jason; Budoff, Matthew J; Kaufman, Joel D; Kronmal, Richard A; Brown, Elizabeth R

    2012-07-02

    Extent of atherosclerosis measured by amount of coronary artery calcium (CAC) in computed tomography (CT) has been traditionally assessed using thresholded scoring methods, such as the Agatston score (AS). These thresholded scores have value in clinical prediction, but important information might exist below the threshold, which would have important advantages for understanding genetic, environmental, and other risk factors in atherosclerosis. We developed a semi-automated threshold-free scoring method, the spatially weighted calcium score (SWCS) for CAC in the Multi-Ethnic Study of Atherosclerosis (MESA). Chest CT scans were obtained from 6814 participants in the Multi-Ethnic Study of Atherosclerosis (MESA). The SWCS and the AS were calculated for each of the scans. Cox proportional hazards models and linear regression models were used to evaluate the associations of the scores with CHD events and CHD risk factors. CHD risk factors were summarized using a linear predictor. Among all participants and participants with AS > 0, the SWCS and AS both showed similar strongly significant associations with CHD events (hazard ratios, 1.23 and 1.19 per doubling of SWCS and AS; 95% CI, 1.16 to 1.30 and 1.14 to 1.26) and CHD risk factors (slopes, 0.178 and 0.164; 95% CI, 0.162 to 0.195 and 0.149 to 0.179). Even among participants with AS = 0, an increase in the SWCS was still significantly associated with established CHD risk factors (slope, 0.181; 95% CI, 0.138 to 0.224). The SWCS appeared to be predictive of CHD events even in participants with AS = 0, though those events were rare as expected. The SWCS provides a valid, continuous measure of CAC suitable for quantifying the extent of atherosclerosis without a threshold, which will be useful for examining novel genetic and environmental risk factors for atherosclerosis.

  17. Modeling and analysis of energy quantization effects on single electron inverter performance

    NASA Astrophysics Data System (ADS)

    Dan, Surya Shankar; Mahapatra, Santanu

    2009-08-01

    In this paper, for the first time, the effects of energy quantization on single electron transistor (SET) inverter performance are analyzed through analytical modeling and Monte Carlo simulations. It is shown that energy quantization mainly changes the Coulomb blockade region and drain current of SET devices and thus affects the noise margin, power dissipation, and the propagation delay of SET inverter. A new analytical model for the noise margin of SET inverter is proposed which includes the energy quantization effects. Using the noise margin as a metric, the robustness of SET inverter is studied against the effects of energy quantization. A compact expression is developed for a novel parameter quantization threshold which is introduced for the first time in this paper. Quantization threshold explicitly defines the maximum energy quantization that an SET inverter logic circuit can withstand before its noise margin falls below a specified tolerance level. It is found that SET inverter designed with CT:CG=1/3 (where CT and CG are tunnel junction and gate capacitances, respectively) offers maximum robustness against energy quantization.

  18. Comparison of CT-derived Ventilation Maps with Deposition Patterns of Inhaled Microspheres in Rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacob, Rick E.; Lamm, W. J.; Einstein, Daniel R.

    2015-04-01

    Purpose: Computer models for inhalation toxicology and drug-aerosol delivery studies rely on ventilation pattern inputs for predictions of particle deposition and vapor uptake. However, changes in lung mechanics due to disease can impact airflow dynamics and model results. It has been demonstrated that non-invasive, in vivo, 4DCT imaging (3D imaging at multiple time points in the breathing cycle) can be used to map heterogeneities in ventilation patterns under healthy and disease conditions. The purpose of this study was to validate ventilation patterns measured from CT imaging by exposing the same rats to an aerosol of fluorescent microspheres (FMS) and examiningmore » particle deposition patterns using cryomicrotome imaging. Materials and Methods: Six male Sprague-Dawley rats were intratracheally instilled with elastase to a single lobe to induce a heterogeneous disease. After four weeks, rats were imaged over the breathing cycle by CT then immediately exposed to an aerosol of ~1µm FMS for ~5 minutes. After the exposure, the lungs were excised and prepared for cryomicrotome imaging, where a 3D image of FMS deposition was acquired using serial sectioning. Cryomicrotome images were spatially registered to match the live CT images to facilitate direct quantitative comparisons of FMS signal intensity with the CT-based ventilation maps. Results: Comparisons of fractional ventilation in contiguous, non-overlapping, 3D regions between CT-based ventilation maps and FMS images showed strong correlations in fractional ventilation (r=0.888, p<0.0001). Conclusion: We conclude that ventilation maps derived from CT imaging are predictive of the 1µm aerosol deposition used in ventilation-perfusion heterogeneity inhalation studies.« less

  19. The retrospective binning method improves the consistency of phase binning in respiratory-gated PET/CT

    NASA Astrophysics Data System (ADS)

    Didierlaurent, D.; Ribes, S.; Batatia, H.; Jaudet, C.; Dierickx, L. O.; Zerdoud, S.; Brillouet, S.; Caselles, O.; Courbon, F.

    2012-12-01

    This study assesses the accuracy of prospective phase-gated PET/CT data binning and presents a retrospective data binning method that improves image quality and consistency. Respiratory signals from 17 patients who underwent 4D PET/CT were analysed to evaluate the reproducibility of temporal triggers used for the standard phase-based gating method. Breathing signals were reprocessed to implement retrospective PET data binning. The mean and standard deviation of time lags between automatic triggers provided by the Real-time Position Management (RPM, Varian) gating device and inhalation peaks derived from respiratory curves were computed for each patient. The total number of respiratory cycles available for 4D PET/CT according to the binning mode (prospective versus retrospective) was compared. The maximum standardized uptake value (SUVmax), biological tumour volume (BTV) and tumour trajectory measures were determined from the PET/CT images of five patients. Compared to retrospective binning (RB), prospective gating approach led to (i) a significant loss in breathing cycles (15%) and (ii) the inconsistency of data binning due to temporal dispersion of triggers (average 396 ms). Consequently, tumour characterization could be impacted. In retrospective mode, SUVmax was up to 27% higher, where no significant difference appeared in BTV. In addition, prospective mode gave an inconsistent spatial location of the tumour throughout the bins. Improved consistency with breathing patterns and greater motion amplitude of the tumour centroid were observed with retrospective mode. The detection of the tumour motion and trajectory was improved also for small temporal dispersion of triggers. This study shows that the binning mode could have a significant impact on 4D PET images. The consistency of triggers with breathing signals should be checked before clinical use of gated PET/CT images, and our RB method improves 4D PET/CT image quantification.

  20. Gas ultrasonic flow rate measurement through genetic-ant colony optimization based on the ultrasonic pulse received signal model

    NASA Astrophysics Data System (ADS)

    Hou, Huirang; Zheng, Dandan; Nie, Laixiao

    2015-04-01

    For gas ultrasonic flowmeters, the signals received by ultrasonic sensors are susceptible to noise interference. If signals are mingled with noise, a large error in flow measurement can be caused by triggering mistakenly using the traditional double-threshold method. To solve this problem, genetic-ant colony optimization (GACO) based on the ultrasonic pulse received signal model is proposed. Furthermore, in consideration of the real-time performance of the flow measurement system, the improvement of processing only the first three cycles of the received signals rather than the whole signal is proposed. Simulation results show that the GACO algorithm has the best estimation accuracy and ant-noise ability compared with the genetic algorithm, ant colony optimization, double-threshold and enveloped zero-crossing. Local convergence doesn’t appear with the GACO algorithm until -10 dB. For the GACO algorithm, the converging accuracy and converging speed and the amount of computation are further improved when using the first three cycles (called GACO-3cycles). Experimental results involving actual received signals show that the accuracy of single-gas ultrasonic flow rate measurement can reach 0.5% with GACO-3 cycles, which is better than with the double-threshold method.

  1. In-situ X-ray CT results of damage evolution in L6 ordinary chondrite meteorites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuadra, Jefferson A.; Hazeli, Kavan; Ramesh, K. T.

    2016-06-17

    These are slides about in-situ X-ray CT results of damage evolution in L6 ordinary chondrite meteorites. The following topics are covered: mechanical and thermal damage characterization, list of Grosvenor Mountain (GRO) meteorite samples, in-situ x-ray compression test setup, GRO-chipped reference at 0 N - existing cracks, GRO-chipped loaded at 1580 N, in-situ x-ray thermal fatigue test setup, GRO-B14 room temperature reference, GRO-B14 Cycle 47 at 200°C, GRO-B14 Cycle 47 at room temperature, conclusions from qualitative analysis, future work and next steps. Conclusions are the following: Both GRO-Chipped and GRO-B14 had existing voids and cracks within the volume. These sites withmore » existing damage were selected for CT images from mechanically and thermally loaded scans since they are prone to damage initiation. The GRO-Chipped sample was loaded to 1580 N which resulted in a 14% compressive engineering strain, calculated using LVDT. Based on the CT cross sectional images, the GRO-B14 sample at 200°C has a thermal expansion of approximately 96 μm in height (i.e. ~1.6% engineering strain).« less

  2. CMOS Active Pixel Sensors as energy-range detectors for proton Computed Tomography.

    PubMed

    Esposito, M; Anaxagoras, T; Evans, P M; Green, S; Manolopoulos, S; Nieto-Camero, J; Parker, D J; Poludniowski, G; Price, T; Waltham, C; Allinson, N M

    2015-06-03

    Since the first proof of concept in the early 70s, a number of technologies has been proposed to perform proton CT (pCT), as a means of mapping tissue stopping power for accurate treatment planning in proton therapy. Previous prototypes of energy-range detectors for pCT have been mainly based on the use of scintillator-based calorimeters, to measure proton residual energy after passing through the patient. However, such an approach is limited by the need for only a single proton passing through the energy-range detector in a read-out cycle. A novel approach to this problem could be the use of pixelated detectors, where the independent read-out of each pixel allows to measure simultaneously the residual energy of a number of protons in the same read-out cycle, facilitating a faster and more efficient pCT scan. This paper investigates the suitability of CMOS Active Pixel Sensors (APSs) to track individual protons as they go through a number of CMOS layers, forming an energy-range telescope. Measurements performed at the iThemba Laboratories will be presented and analysed in terms of correlation, to confirm capability of proton tracking for CMOS APSs.

  3. Selection of Reliable Reference Genes for Gene Expression Studies of a Promising Oilseed Crop, Plukenetia volubilis, by Real-Time Quantitative PCR

    PubMed Central

    Niu, Longjian; Tao, Yan-Bin; Chen, Mao-Sheng; Fu, Qiantang; Li, Chaoqiong; Dong, Yuling; Wang, Xiulan; He, Huiying; Xu, Zeng-Fu

    2015-01-01

    Real-time quantitative PCR (RT-qPCR) is a reliable and widely used method for gene expression analysis. The accuracy of the determination of a target gene expression level by RT-qPCR demands the use of appropriate reference genes to normalize the mRNA levels among different samples. However, suitable reference genes for RT-qPCR have not been identified in Sacha inchi (Plukenetia volubilis), a promising oilseed crop known for its polyunsaturated fatty acid (PUFA)-rich seeds. In this study, using RT-qPCR, twelve candidate reference genes were examined in seedlings and adult plants, during flower and seed development and for the entire growth cycle of Sacha inchi. Four statistical algorithms (delta cycle threshold (ΔCt), BestKeeper, geNorm, and NormFinder) were used to assess the expression stabilities of the candidate genes. The results showed that ubiquitin-conjugating enzyme (UCE), actin (ACT) and phospholipase A22 (PLA) were the most stable genes in Sacha inchi seedlings. For roots, stems, leaves, flowers, and seeds from adult plants, 30S ribosomal protein S13 (RPS13), cyclophilin (CYC) and elongation factor-1alpha (EF1α) were recommended as reference genes for RT-qPCR. During the development of reproductive organs, PLA, ACT and UCE were the optimal reference genes for flower development, whereas UCE, RPS13 and RNA polymerase II subunit (RPII) were optimal for seed development. Considering the entire growth cycle of Sacha inchi, UCE, ACT and EF1α were sufficient for the purpose of normalization. Our results provide useful guidelines for the selection of reliable reference genes for the normalization of RT-qPCR data for seedlings and adult plants, for reproductive organs, and for the entire growth cycle of Sacha inchi. PMID:26047338

  4. Atmospheric CO2 at Waliguan station in China: Transport climatology, temporal patterns and source-sink region representativeness

    NASA Astrophysics Data System (ADS)

    Cheng, Siyang; An, Xingqin; Zhou, Lingxi; Tans, Pieter P.; Jacobson, Andy

    2017-06-01

    In order to explore where the source and sink have the greatest impact on CO2 background concentration at Waliguan (WLG) station, a statistical method is here proposed to calculate the representative source-sink region. The key to this method is to find the best footprint threshold, and the study is carried out in four parts. Firstly, transport climatology, expressed by total monthly footprint, was simulated by FLEXPART on a 7-day time scale. Surface CO2 emissions in Eurasia frequently transported to WLG station. WLG station was mainly influenced by the westerlies in winter and partly controlled by the Southeast Asian monsoon in summer. Secondly, CO2 concentrations, simulated by CT2015, were processed and analyzed through data quality control, screening, fitting and comparing. CO2 concentrations displayed obvious seasonal variation, with the maximum and minimum concentration appearing in April and August, respectively. The correlation of CO2 fitting background concentrations was R2 = 0.91 between simulation and observation. The temporal patterns were mainly correlated with CO2 exchange of biosphere-atmosphere, human activities and air transport. Thirdly, for the monthly CO2 fitting background concentrations from CT2015, a best footprint threshold was found based on correlation analysis and numerical iteration using the data of footprints and emissions. The grid cells where monthly footprints were greater than the best footprint threshold were the best threshold area corresponding to representative source-sink region. The representative source-sink region of maximum CO2 concentration in April was primarily located in Qinghai province, but the minimum CO2 concentration in August was mainly influenced by emissions in a wider region. Finally, we briefly presented the CO2 source-sink characteristics in the best threshold area. Generally, the best threshold area was a carbon sink. The major source and sink were relatively weak owing to less human activities and vegetation types in this high altitude area. CO2 concentrations were more influenced by human activities when air mass passed through many urban areas in summer. Therefore, the combination of footprints and emissions is an effective approach for assessing the source-sink region representativeness of CO2 background concentration.

  5. A Registration Method Based on Contour Point Cloud for 3D Whole-Body PET and CT Images

    PubMed Central

    Yang, Qiyao; Wang, Zhiguo; Zhang, Guoxu

    2017-01-01

    The PET and CT fusion image, combining the anatomical and functional information, has important clinical meaning. An effective registration of PET and CT images is the basis of image fusion. This paper presents a multithread registration method based on contour point cloud for 3D whole-body PET and CT images. Firstly, a geometric feature-based segmentation (GFS) method and a dynamic threshold denoising (DTD) method are creatively proposed to preprocess CT and PET images, respectively. Next, a new automated trunk slices extraction method is presented for extracting feature point clouds. Finally, the multithread Iterative Closet Point is adopted to drive an affine transform. We compare our method with a multiresolution registration method based on Mattes Mutual Information on 13 pairs (246~286 slices per pair) of 3D whole-body PET and CT data. Experimental results demonstrate the registration effectiveness of our method with lower negative normalization correlation (NC = −0.933) on feature images and less Euclidean distance error (ED = 2.826) on landmark points, outperforming the source data (NC = −0.496, ED = 25.847) and the compared method (NC = −0.614, ED = 16.085). Moreover, our method is about ten times faster than the compared one. PMID:28316979

  6. Comparison of electron-beam and ungated helical CT in detecting coronary arterial calcification by using a working heart phantom and artificial coronary arteries.

    PubMed

    Hopper, Kenneth D; Strollo, Diane C; Mauger, David T

    2002-02-01

    To determine the sensitivity and specificity of cardiac gated electron-beam computed tomography (CT) and ungated helical CT in detecting and quantifying coronary arterial calcification (CAC) by using a working heart phantom and artificial coronary arteries. A working heart phantom simulating normal cardiac motion and providing attenuation equal to that of an adult thorax was used. Thirty tubes with a 3-mm inner diameter were internally coated with pulverized human cortical bone mixed with epoxy glue to simulate minimal (n = 10), mild (n = 10), or severe (n = 10) calcified plaques. Ten additional tubes were not coated and served as normal controls. The tubes were attached to the same location on the phantom heart and scanned with electron-beam CT and helical CT in horizontal and vertical planes. Actual plaque calcium content was subsequently quantified with atopic spectroscopy. Two blinded experienced radiologic imaging teams, one for each CT system, separately measured calcium content in the model vessels by using a Hounsfield unit threshold of 130 or greater. The sensitivity and specificity of electron-beam CT in detecting CAC were 66.1% and 80.0%, respectively. The sensitivity and specificity of helical CT were 96.4% and 95.0%, respectively. Electron-beam CT was less reliable when vessels were oriented vertically (sensitivity and specificity, 71.4% and 70%; 95% CI: 39.0%, 75.0%) versus horizontally (sensitivity and specificity, 60.7% and 90.0%; 95% CI: 48.0%, 82.0%). When a correction factor was applied, the volume of calcified plaque was statistically better quantified with helical CT than with electron-beam CT (P =.004). Ungated helical CT depicts coronary arterial calcium better than does gated electron-beam CT. When appropriate correction factors are applied, helical CT is superior to electron-beam CT in quantifying coronary arterial calcium. Although further work must be done to optimize helical CT grading systems and scanning protocols, the data of this study demonstrated helical CT's inherent advantage over currently commercially available electron-beam CT systems in CAC detection and quantification.

  7. Consistent Evaluation of ACOS-GOSAT, BESD-SCIAMACHY, CarbonTracker, and MACC Through Comparisons to TCCON

    NASA Technical Reports Server (NTRS)

    Kulawik, Susan; Wunch, Debra; O’Dell, Christopher; Frankenberg, Christian; Reuter, Maximilian; Chevallier, Frederic; Oda, Tomohiro; Sherlock, Vanessa; Buchwitz, Michael; Osterman, Greg; hide

    2016-01-01

    Consistent validation of satellite CO2 estimates is a prerequisite for using multiple satellite CO2 measurements for joint flux inversion, and for establishing an accurate long-term atmospheric CO2 data record. Harmonizing satellite CO2 measurements is particularly important since the differences in instruments, observing geometries, sampling strategies, etc. imbue different measurement characteristics in the various satellite CO2 data products. We focus on validating model and satellite observation attributes that impact flux estimates and CO2 assimilation, including accurate error estimates, correlated and random errors, overall biases, biases by season and latitude, the impact of coincidence criteria, validation of seasonal cycle phase and amplitude, yearly growth, and daily variability. We evaluate dry-air mole fraction (X(sub CO2)) for Greenhouse gases Observing SATellite (GOSAT) (Atmospheric CO2 Observations from Space, ACOS b3.5) and SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) (Bremen Optimal Estimation DOAS, BESD v2.00.08) as well as the CarbonTracker (CT2013b) simulated CO2 mole fraction fields and the Monitoring Atmospheric Composition and Climate (MACC) CO2 inversion system (v13.1) and compare these to Total Carbon Column Observing Network (TCCON) observations (GGG2012/2014). We find standard deviations of 0.9, 0.9, 1.7, and 2.1 parts per million vs. TCCON for CT2013b, MACC, GOSAT, and SCIAMACHY, respectively, with the single observation errors 1.9 and 0.9 times the predicted errors for GOSAT and SCIAMACHY, respectively. We quantify how satellite error drops with data averaging by interpreting according to (error(sup 2) equals a(sup 2) plus b(sup 2) divided by n (with n being the number of observations averaged, a the systematic (correlated) errors, and b the random (uncorrelated) errors). a and b are estimated by satellites, coincidence criteria, and hemisphere. Biases at individual stations have year-to-year variability of 0.3 parts per million, with biases larger than the TCCON predicted bias uncertainty of 0.4 parts per million at many stations. We find that GOSAT and CT2013b under-predict the seasonal cycle amplitude in the Northern Hemisphere (NH) between 46 and 53 degrees North latitude, MACC over-predicts between 26 and 37 degrees North latitude, and CT2013b under-predicts the seasonal cycle amplitude in the Southern Hemisphere (SH). The seasonal cycle phase indicates whether a data set or model lags another data set in time. We find that the GOSAT measurements improve the seasonal cycle phase substantially over the prior while SCIAMACHY measurements improve the phase significantly for just two of seven sites. The models reproduce the measured seasonal cycle phase well except for at Lauder_125HR (CT2013b) and Darwin (MACC). We compare the variability within 1 day between TCCON and models in June-July-August; there is correlation between 0.2 and 0.8 in the NH, with models showing 10-50 percent the variability of TCCON at different stations and CT2013b showing more variability than MACC. This paper highlights findings that provide inputs to estimate flux errors in model assimilations, and places where models and satellites need further investigation, e.g., the SH for models and 45-67 degrees North latitude for GOSAT and CT2013b.

  8. Variability of space climate and its extremes with successive solar cycles

    NASA Astrophysics Data System (ADS)

    Chapman, Sandra; Hush, Phillip; Tindale, Elisabeth; Dunlop, Malcolm; Watkins, Nicholas

    2016-04-01

    Auroral geomagnetic indices coupled with in situ solar wind monitors provide a comprehensive data set, spanning several solar cycles. Space climate can be considered as the distribution of space weather. We can then characterize these observations in terms of changing space climate by quantifying how the statistical properties of ensembles of these observed variables vary between different phases of the solar cycle. We first consider the AE index burst distribution. Bursts are constructed by thresholding the AE time series; the size of a burst is the sum of the excess in the time series for each time interval over which the threshold is exceeded. The distribution of burst sizes is two component with a crossover in behaviour at thresholds ≈ 1000 nT. Above this threshold, we find[1] a range over which the mean burst size is almost constant with threshold for both solar maxima and minima. The burst size distribution of the largest events has a functional form which is exponential. The relative likelihood of these large events varies from one solar maximum and minimum to the next. If the relative overall activity of a solar maximum/minimum can be estimated, these results then constrain the likelihood of extreme events of a given size for that solar maximum/minimum. We next develop and apply a methodology to quantify how the full distribution of geomagnetic indices and upstream solar wind observables are changing between and across different solar cycles. This methodology[2] estimates how different quantiles of the distribution, or equivalently, how the return times of events of a given size, are changing. [1] Hush, P., S. C. Chapman, M. W. Dunlop, and N. W. Watkins (2015), Robust statistical properties of the size of large burst events in AE, Geophys. Res. Lett.,42 doi:10.1002/2015GL066277 [2] Chapman, S. C., D. A. Stainforth, N. W. Watkins, (2013) On estimating long term local climate trends , Phil. Trans. Royal Soc., A,371 20120287 DOI:10.1098/rsta.2012.0287

  9. Comparison of standardized uptake value-based positron emission tomography and computed tomography target volumes in esophageal cancer patients undergoing radiotherapy.

    PubMed

    Vali, Faisal S; Nagda, Suneel; Hall, William; Sinacore, James; Gao, Mingcheng; Lee, Steven H; Hong, Robert; Shoup, Margaret; Emami, Bahman

    2010-11-15

    To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV ≥2, ≥2.5, ≥3, ≥3.5 (SUV(n)); ≥40%, ≥45%, and ≥50% of the maximum (SUV(n%)); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV(Lnσ)). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV(2.5) (0.47 ± 0.03) and SUV(L4σ) (0.48 ± 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV(2.5) (1.18 ± 0.36) and SUV(L4σ) (1.09 ± 0.15). The mean value of the SUVs calculated using the SUV(L4σ) approach was 2.4. Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients. Copyright © 2010 Elsevier Inc. All rights reserved.

  10. Instability and breakdown of the coral-algae symbiosis upon exceedence of the interglacial pCO2 threshold (>260 ppmv): the "missing" Earth-System feedback mechanism

    NASA Astrophysics Data System (ADS)

    Wooldridge, Scott A.

    2017-12-01

    Changes in the atmospheric partial pressure of CO2 ( pCO2) leads to predictable impacts on the surface ocean carbonate system. Here, the importance of atmospheric pCO2 <260 ppmv is established for the optimum performance (and stability) of the algal endosymbiosis employed by a key suite of tropical reef-building coral species. Violation of this symbiotic threshold is revealed as a prerequisite for major historical reef extinction events, glacial-interglacial feedback climate cycles, and the modern decline of coral reef ecosystems. Indeed, it is concluded that this symbiotic threshold enacts a fundamental feedback mechanism needed to explain the characteristic dynamics (and drivers) of the coupled land-ocean-atmosphere carbon cycle of the Earth System since the mid-Miocene, some 25 million yr ago.

  11. Measurement of time delay for a prospectively gated CT simulator.

    PubMed

    Goharian, M; Khan, R F H

    2010-04-01

    For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient's breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) 'X-Ray ON' status signal from the CT scanner in a text file. The TTL 'X-Ray ON' indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 +/- 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery; otherwise the simulation and treatment may not be correlated with the patient's breathing.

  12. The effect of signal duration on the underwater hearing thresholds of two harbor seals (Phoca vitulina) for single tonal signals between 0.2 and 40 kHz.

    PubMed

    Kastelein, Ronald A; Hoek, Lean; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F

    2010-02-01

    The underwater hearing sensitivities of two 2-year-old female harbor seals were quantified in a pool built for acoustic research by using a behavioral psycho-acoustic technique. The animals were trained only to respond when they detected an acoustic signal ("go/no-go" response). Detection thresholds were obtained for pure tone signals (frequencies: 0.2-40 kHz; durations: 0.5-5000 ms, depending on the frequency; 59 frequency-duration combinations). Detection thresholds were quantified by varying the signal amplitude by the 1-up, 1-down staircase method, and were defined as the stimulus levels, resulting in a 50% detection rate. The hearing thresholds of the two seals were similar for all frequencies except for 40 kHz, for which the thresholds differed by, on average, 3.7 dB. There was an inverse relationship between the time constant (tau), derived from an exponential model of temporal integration, and the frequency [log(tau)=2.86-0.94 log(f);tau in ms and f in kHz]. Similarly, the thresholds increased when the pulse was shorter than approximately 780 cycles (independent of the frequency). For pulses shorter than the integration time, the thresholds increased by 9-16 dB per decade reduction in the duration or number of cycles in the pulse. The results of this study suggest that most published hearing thresholds

  13. Segmentation of the ovine lung in 3D CT Images

    NASA Astrophysics Data System (ADS)

    Shi, Lijun; Hoffman, Eric A.; Reinhardt, Joseph M.

    2004-04-01

    Pulmonary CT images can provide detailed information about the regional structure and function of the respiratory system. Prior to any of these analyses, however, the lungs must be identified in the CT data sets. A popular animal model for understanding lung physiology and pathophysiology is the sheep. In this paper we describe a lung segmentation algorithm for CT images of sheep. The algorithm has two main steps. The first step is lung extraction, which identifies the lung region using a technique based on optimal thresholding and connected components analysis. The second step is lung separation, which separates the left lung from the right lung by identifying the central fissure using an anatomy-based method incorporating dynamic programming and a line filter algorithm. The lung segmentation algorithm has been validated by comparing our automatic method to manual analysis for five pulmonary CT datasets. The RMS error between the computer-defined and manually-traced boundary is 0.96 mm. The segmentation requires approximately 10 minutes for a 512x512x400 dataset on a PC workstation (2.40 GHZ CPU, 2.0 GB RAM), while it takes human observer approximately two hours to accomplish the same task.

  14. Joint Segmentation of Anatomical and Functional Images: Applications in Quantification of Lesions from PET, PET-CT, MRI-PET, and MRI-PET-CT Images

    PubMed Central

    Bagci, Ulas; Udupa, Jayaram K.; Mendhiratta, Neil; Foster, Brent; Xu, Ziyue; Yao, Jianhua; Chen, Xinjian; Mollura, Daniel J.

    2013-01-01

    We present a novel method for the joint segmentation of anatomical and functional images. Our proposed methodology unifies the domains of anatomical and functional images, represents them in a product lattice, and performs simultaneous delineation of regions based on random walk image segmentation. Furthermore, we also propose a simple yet effective object/background seed localization method to make the proposed segmentation process fully automatic. Our study uses PET, PET-CT, MRI-PET, and fused MRI-PET-CT scans (77 studies in all) from 56 patients who had various lesions in different body regions. We validated the effectiveness of the proposed method on different PET phantoms as well as on clinical images with respect to the ground truth segmentation provided by clinicians. Experimental results indicate that the presented method is superior to threshold and Bayesian methods commonly used in PET image segmentation, is more accurate and robust compared to the other PET-CT segmentation methods recently published in the literature, and also it is general in the sense of simultaneously segmenting multiple scans in real-time with high accuracy needed in routine clinical use. PMID:23837967

  15. Development of automated extraction method of biliary tract from abdominal CT volumes based on local intensity structure analysis

    NASA Astrophysics Data System (ADS)

    Koga, Kusuto; Hayashi, Yuichiro; Hirose, Tomoaki; Oda, Masahiro; Kitasaka, Takayuki; Igami, Tsuyoshi; Nagino, Masato; Mori, Kensaku

    2014-03-01

    In this paper, we propose an automated biliary tract extraction method from abdominal CT volumes. The biliary tract is the path by which bile is transported from liver to the duodenum. No extraction method have been reported for the automated extraction of the biliary tract from common contrast CT volumes. Our method consists of three steps including: (1) extraction of extrahepatic bile duct (EHBD) candidate regions, (2) extraction of intrahepatic bile duct (IHBD) candidate regions, and (3) combination of these candidate regions. The IHBD has linear structures and intensities of the IHBD are low in CT volumes. We use a dark linear structure enhancement (DLSE) filter based on a local intensity structure analysis method using the eigenvalues of the Hessian matrix for the IHBD candidate region extraction. The EHBD region is extracted using a thresholding process and a connected component analysis. In the combination process, we connect the IHBD candidate regions to each EHBD candidate region and select a bile duct region from the connected candidate regions. We applied the proposed method to 22 cases of CT volumes. An average Dice coefficient of extraction result was 66.7%.

  16. Development of automatic visceral fat volume calculation software for CT volume data.

    PubMed

    Nemoto, Mitsutaka; Yeernuer, Tusufuhan; Masutani, Yoshitaka; Nomura, Yukihiro; Hanaoka, Shouhei; Miki, Soichiro; Yoshikawa, Takeharu; Hayashi, Naoto; Ohtomo, Kuni

    2014-01-01

    To develop automatic visceral fat volume calculation software for computed tomography (CT) volume data and to evaluate its feasibility. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30) in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy.

  17. MO-DE-207A-09: Low-Dose CT Image Reconstruction Via Learning From Different Patient Normal-Dose Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, H; Xing, L; Liang, Z

    Purpose: To investigate a novel low-dose CT (LdCT) image reconstruction strategy for lung CT imaging in radiation therapy. Methods: The proposed approach consists of four steps: (1) use the traditional filtered back-projection (FBP) method to reconstruct the LdCT image; (2) calculate structure similarity (SSIM) index between the FBP-reconstructed LdCT image and a set of normal-dose CT (NdCT) images, and select the NdCT image with the highest SSIM as the learning source; (3) segment the NdCT source image into lung and outside tissue regions via simple thresholding, and adopt multiple linear regression to learn high-order Markov random field (MRF) pattern formore » each tissue region in the NdCT source image; (4) segment the FBP-reconstructed LdCT image into lung and outside regions as well, and apply the learnt MRF prior in each tissue region for statistical iterative reconstruction of the LdCT image following the penalized weighted least squares (PWLS) framework. Quantitative evaluation of the reconstructed images was based on the signal-to-noise ratio (SNR), local binary pattern (LBP) and histogram of oriented gradients (HOG) metrics. Results: It was observed that lung and outside tissue regions have different MRF patterns predicted from the NdCT. Visual inspection showed that our method obviously outperformed the traditional FBP method. Comparing with the region-smoothing PWLS method, our method has, in average, 13% increase in SNR, 15% decrease in LBP difference, and 12% decrease in HOG difference from reference standard for all regions of interest, which indicated the superior performance of the proposed method in terms of image resolution and texture preservation. Conclusion: We proposed a novel LdCT image reconstruction method by learning similar image characteristics from a set of NdCT images, and the to-be-learnt NdCT image does not need to be scans from the same subject. This approach is particularly important for enhancing image quality in radiation therapy.« less

  18. Modification of atrioventricular nodal electrophysiology by selective radiofrequency delivery on the anterior or posterior approaches.

    PubMed

    Chorro, F J; Sanchis, J; Such, L; Artal, L; Llavador, J J; Llavador, E; Monmeneu, J V; López-Merino, V

    1997-05-01

    An analysis was made in 14 isolated and perfused rabbit hearts of the electrophysiological effects of selective radiofrequency (RF) delivery in the anterior (group I, n = 7) or posterior zone (group II, n = 7) of the Koch triangle, with the aim of modifying atrioventricular nodal (AVN) conduction without suppressing 1:1 transmission. After opening the right atrium, RF was delivered (0.5 W) with a 1-mm diameter unipolar electrode positioned in the selected zone until a prolongation of no less than 15% was obtained in the Wenckebach cycle length (WCL). Before and after (30 min) RF, anterograde and retrograde AVN refractoriness and conduction were evaluated, stimulating from the crista terminalis (CT), the interatrial septum (IAS), and from the RV epicardium. After RF, the following percentage increments were observed in group I: AH(CT) = 36% +/- 9%, AH(IAS) = 38% +/- 11%, WCL(CT) = 28% +/- 8%, WCL(IAS) = 22% +/- 6%, functional refractory period (FRP) of the AVN(CT) = 13% +/- 11%, FRP-AVN(IAS) = 13% +/- 8%, retrograde WCL = 20% +/- 19%, and retrograde FRPVA = 13% +/- 16%. The increments observed in group II and the significances of the differences with respect to group I were: AH(CT) = 11% +/- 14% (P < 0.01), AH(IAS) = 19% +/- 32% (NS), WCL(CT) = 42% +/- 14% (P < 0.05), WCL(IAS) = 42% +/- 16% (P < 0.01), FRP-AVN(CT) = 28% +/- 28% (NS), FRP-AVN(LAS) = 21% +/- 19% (NS), retrograde WCL = 35% +/- 24% (NS), and retrograde FRP = 16% +/- 13% (NS). In both groups, the AH interval variations were not correlated with those of the rest of the parameters analyzed. Truncated nodal function curves suggestive of a dual AV nodal pathway were obtained in three experiments, though in only one of them was this observed under basal conditions. In the other two experiments, with dual AV nodal physiology only after RF (one from each group), AV nodal reentrant tachycardias were triggered with atrial extrastimulus at coupling intervals equal to or shorter than at those that cause a sudden lengthening of the AH interval, RF delivered in the anterior and posterior zones of the Koch triangle produced effects of different magnitude on the AH interval and Wenckebach cycle length. In the anterior zone the AH interval was prolonged to a greater extent, while in the posterior zone the effects were greater on the Wenckebach cycle length. No correlation existed between the variations in AH interval and Wenckebach cycle length, regardless of where RF was delivered. The evaluation of anterograde AV nodal refractoriness was similar when stimulating from the crista terminalis or from the interatrial septum. By delivering RF, it was possible to induce dual AV nodal physiology and reentrant tachycardias.

  19. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guidemore » provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.« less

  20. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    NASA Astrophysics Data System (ADS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  1. K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging

    PubMed Central

    Ghadiri, H; Ay, M R; Shiran, M B; Soltanian-Zadeh, H

    2013-01-01

    Objective: Recently introduced energy-sensitive X-ray CT makes it feasible to discriminate different nanoparticulate contrast materials. The purpose of this work is to present a K-edge ratio method for differentiating multiple simultaneous contrast agents using spectral CT. Methods: The ratio of two images relevant to energy bins straddling the K-edge of the materials is calculated using an analytic CT simulator. In the resulting parametric map, the selected contrast agent regions can be identified using a thresholding algorithm. The K-edge ratio algorithm is applied to spectral images of simulated phantoms to identify and differentiate up to four simultaneous and targeted CT contrast agents. Results: We show that different combinations of simultaneous CT contrast agents can be identified by the proposed K-edge ratio method when energy-sensitive CT is used. In the K-edge parametric maps, the pixel values for biological tissues and contrast agents reach a maximum of 0.95, whereas for the selected contrast agents, the pixel values are larger than 1.10. The number of contrast agents that can be discriminated is limited owing to photon starvation. For reliable material discrimination, minimum photon counts corresponding to 140 kVp, 100 mAs and 5-mm slice thickness must be used. Conclusion: The proposed K-edge ratio method is a straightforward and fast method for identification and discrimination of multiple simultaneous CT contrast agents. Advances in knowledge: A new spectral CT-based algorithm is proposed which provides a new concept of molecular CT imaging by non-iteratively identifying multiple contrast agents when they are simultaneously targeting different organs. PMID:23934964

  2. Discussion on the alteration of FDG uptake by the breast according to the menstrual cycle in 18F-FDG PET/CT

    NASA Astrophysics Data System (ADS)

    Park, H. H.; Park, M. S.; Lee, C. H.; Cho, J. H.; Dong, K. R.; Chung, W. K.

    2012-09-01

    18F-FDG (fluorodeoxyglucose) PET (positron emission tomography)/CT (computed tomography) is a useful modality for identifying high-glucose-consuming cells, such as cancer cells, by the glucose metabolism of FDG. FDG is taken up by cancer and inflammatory cells, but occasionally there is also some FDG uptake by normal tissues as a result of their individual physiological characteristics. In particular, in fertile females, unusual FDG uptake in the breast changes according to the stages in the menstrual cycle, which can adversely affect a diagnosis. Therefore, this study examined the change in breast FDG uptake in the menstrual cycle on 18F-FDG PET/CT. One hundred and sixty females (34±3.5 years old), who had not undergone a gynecologic anamnesis and had a regular menstrual cycle over the previous 6 months, were examined from March 2010 to February 2011. The subjects were divided into the following four groups (each with 40 patients): flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator Ver. 0.14 and history taking. Discovery Ste was used as the PET/CT. The standardized uptake values (SUVs) on the accumulated region on the breast were analyzed, and three nuclear medicine specialists performed a blind test. The SUVs on the breast were the flow phase (1.64±0.25), proliferative phase (0.93±0.28), ovulatory phase (1.66±0.26) and secretory phase (1.77±0.28). A high uptake value was observed in the secretory, flow and ovulatory phases. The FDG accumulation of the breast was divided into the following three grades compared with the lung and liver by gross analysis: the breast uptake was equal to the lung (Grade I), between the lung and liver (Grade II) and equal to or greater than the liver (Grade III). These results showed a high uptake value in the secretory, flow and ovulatory phases. In fertile females, the FDG uptake of the breast showed changes according to the menstrual cycle, which can be used to improve the diagnosis of breast disease. Therefore, the false-negative findings of breast disease can be reduced by performing an examination at the appropriate period through history taking and considering the individual menstrual cycle.

  3. Synthesis and characterization of 2D molybdenum carbide (MXene)

    DOE PAGES

    Halim, Joseph; Kota, Sankalp; Lukatskaya, Maria R.; ...

    2016-02-17

    Large scale synthesis and delamination of 2D Mo 2CT x (where T is a surface termination group) has been achieved by selectively etching gallium from the recently discovered nanolaminated, ternary transition metal carbide Mo 2Ga 2C. Different synthesis and delamination routes result in different flake morphologies. The resistivity of free-standing Mo 2CT x films increases by an order of magnitude as the temperature is reduced from 300 to 10 K, suggesting semiconductor-like behavior of this MXene, in contrast to Ti 3C 2T x which exhibits metallic behavior. At 10 K, the magnetoresistance is positive. Additionally, changes in electronic transport aremore » observed upon annealing of the films. When 2 μm thick films are tested as electrodes in supercapacitors, capacitances as high as 700 F cm –3 in a 1 m sulfuric acid electrolyte and high capacity retention for at least 10,000 cycles at 10 A g –1 are obtained. Free-standing Mo 2CT x films, with ≈8 wt% carbon nanotubes, perform well when tested as an electrode material for Li-ions, especially at high rates. In conclusion, at 20 and 131 C cycling rates, stable reversible capacities of 250 and 76 mAh g –1, respectively, are achieved for over 1000 cycles.« less

  4. Composite Aircraft Life Cycle Cost Estimating Model

    DTIC Science & Technology

    2011-03-01

    X. The masked fit of the lines are as follows: • Part Count Percentage Reduction for Design hours ( HRE %) = • Part Count Percentage Reduction...multiplied by the respective labor rate (LR). Currently, CT is a percentage of total non- recurring development cost. HRE corresponds to recurring...Empty Weight Velocity RENGR HRE CRE 46 Figure 14: Non-Recurring Engineering CER Currently, CT is a percentage of non-recurring development

  5. Effect of artificial aging on the bond durability of fissure sealants.

    PubMed

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p < 0.05). Longer thermocycling (10,000 cycles) resulted in more decreases in µTBS for group PEL and PPC, while the strength of the UX group remained relatively unchanged. After thermocycling, considerable silver penetration could be seen at the sealant/enamel interface of the EL group in micro-CT images. The etch-and-rinse procedure for sealant application promotes higher bond strength under artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  6. Discrimination of clinically significant calcium salts using MARS spectral CT

    NASA Astrophysics Data System (ADS)

    Kirkbride, T. E.; Raja, A.; Mueller, K.; Bateman, C. J.; Becce, F.; Anderson, N.

    2017-03-01

    Calcium compounds within tissues are usually a sign of pathology, and calcium crystal type is often a pointer to the diagnosis. There are clinical advantages in being able to determine the quantity and type of calcifications non-invasively in cardiovascular, genitourinary and musculoskeletal disorders, and treatment differs depending on the crystal type and quantity. The problem arises when trying to distinguish between different calcium compounds within the same image due to their similar attenuation properties. There are spectroscopic differences between calcium salts at very low energies. As calcium oxalate and calcium hydroxyapatite can co-exist in breast and musculoskeletal pathologies of the breast, we wished to determine whether Spectral CT could distinguish between them in the same image at clinical X-ray energy ranges. Energy thresholds of 15, 22, 29 and 36keV and tube voltages of 50, 80 and 110kVp were chosen, and images were analysed to determine the percentage difference in the attenuation coefficients of calcium hydroxyapatite samples at concentrations of 54.3, 211.7, 808.5 and 1169.3mg/ml, and calcium oxalate at a concentration of 2000 mg/ml. The two lower concentrations of calcium hydroxyapatite were distinguishable from calcium oxalate at all energies and all tube voltages, whereas the ability to discriminate oxalate from hydroxyapatite at higher concentrations was dependent on the threshold energy but only mildly dependent on the tube voltage used. Spectral CT shows promise for distinguishing clinically important calcium salts.

  7. Three-dimensional reconstruction of teeth and jaws based on segmentation of CT images using watershed transformation.

    PubMed

    Naumovich, S S; Naumovich, S A; Goncharenko, V G

    2015-01-01

    The objective of the present study was the development and clinical testing of a three-dimensional (3D) reconstruction method of teeth and a bone tissue of the jaw on the basis of CT images of the maxillofacial region. 3D reconstruction was performed using the specially designed original software based on watershed transformation. Computed tomograms in digital imaging and communications in medicine format obtained on multispiral CT and CBCT scanners were used for creation of 3D models of teeth and the jaws. The processing algorithm is realized in the stepwise threshold image segmentation with the placement of markers in the mode of a multiplanar projection in areas relating to the teeth and a bone tissue. The developed software initially creates coarse 3D models of the entire dentition and the jaw. Then, certain procedures specify the model of the jaw and cut the dentition into separate teeth. The proper selection of the segmentation threshold is very important for CBCT images having a low contrast and high noise level. The developed semi-automatic algorithm of multispiral and cone beam computed tomogram processing allows 3D models of teeth to be created separating them from a bone tissue of the jaws. The software is easy to install in a dentist's workplace, has an intuitive interface and takes little time in processing. The obtained 3D models can be used for solving a wide range of scientific and clinical tasks.

  8. Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

    PubMed

    Fischer, N; Pinggera, L; Weichbold, V; Dejaco, D; Schmutzhard, J; Widmann, G

    2015-02-01

    Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and to evaluate its influence on auditory outcome. This retrospective single-center study analyzed a consecutive series of 63 cochlear implantations with various straight electrodes. The placement of the electrode array was evaluated by using multiplanar reconstructed conebeam CT images. For the auditory outcome, we compared the aided hearing thresholds and the charge units of maximum comfortable loudness level at weeks 6, 12, and 24 after implantation. In 7.9% of the cases, the electrode array showed scalar dislocation. In all cases, the electrode array penetrated the basal membrane within 45° of the electrode insertion. All 3 cases of cochleostomy were dislocated in the first 45° segment. No hearing differences were noted, but the charge units of maximum comfortable loudness level seemed to increase with time in patients with dislocations. The intracochlear dislocation rate of various straight electrodes detected by conebeam CT images is relatively low. Scalar dislocation may not negatively influence the hearing threshold but may require an increase of the necessary stimulus charge and should be reported by the radiologist. © 2015 by American Journal of Neuroradiology.

  9. 3D Structure of Tillage Soils

    NASA Astrophysics Data System (ADS)

    González-Torre, Iván; Losada, Juan Carlos; Falconer, Ruth; Hapca, Simona; Tarquis, Ana M.

    2015-04-01

    Soil structure may be defined as the spatial arrangement of soil particles, aggregates and pores. The geometry of each one of these elements, as well as their spatial arrangement, has a great influence on the transport of fluids and solutes through the soil. Fractal/Multifractal methods have been increasingly applied to quantify soil structure thanks to the advances in computer technology (Tarquis et al., 2003). There is no doubt that computed tomography (CT) has provided an alternative for observing intact soil structure. These CT techniques reduce the physical impact to sampling, providing three-dimensional (3D) information and allowing rapid scanning to study sample dynamics in near real-time (Houston et al., 2013a). However, several authors have dedicated attention to the appropriate pore-solid CT threshold (Elliot and Heck, 2007; Houston et al., 2013b) and the better method to estimate the multifractal parameters (Grau et al., 2006; Tarquis et al., 2009). The aim of the present study is to evaluate the effect of the algorithm applied in the multifractal method (box counting and box gliding) and the cube size on the calculation of generalized fractal dimensions (Dq) in grey images without applying any threshold. To this end, soil samples were extracted from different areas plowed with three tools (moldboard, chissel and plow). Soil samples for each of the tillage treatment were packed into polypropylene cylinders of 8 cm diameter and 10 cm high. These were imaged using an mSIMCT at 155keV and 25 mA. An aluminium filter (0.25 mm) was applied to reduce beam hardening and later several corrections where applied during reconstruction. References Elliot, T.R. and Heck, R.J. 2007. A comparison of 2D and 3D thresholding of CT imagery. Can. J. Soil Sci., 87(4), 405-412. Grau, J, Médez, V.; Tarquis, A.M., Saa, A. and Díaz, M.C.. 2006. Comparison of gliding box and box-counting methods in soil image analysis. Geoderma, 134, 349-359. González-Torres, Iván. Theory and application of multifractal analysis methods in images for the study of soil structure. Master thesis, UPM, 2014. Houston, A.N.; S. Schmidt, A.M. Tarquis, W. Otten, P.C. Baveye, S.M. Hapca. Effect of scanning and image reconstruction settings in X-ray computed tomography on soil image quality and segmentation performance. Geoderma, 207-208, 154-165, 2013a. Houston, A, Otten, W., Baveye, Ph., Hapca, S. Adaptive-Window Indicator Kriging: A Thresholding Method for Computed Tomography, Computers & Geosciences, 54, 239-248, 2013b. Tarquis, A.M., R.J. Heck, D. Andina, A. Alvarez and J.M. Antón. Multifractal analysis and thresholding of 3D soil images. Ecological Complexity, 6, 230-239, 2009. Tarquis, A.M.; D. Giménez, A. Saa, M.C. Díaz. and J.M. Gascó. Scaling and Multiscaling of Soil Pore Systems Determined by Image Analysis. Scaling Methods in Soil Systems. Pachepsky, Radcliffe and Selim Eds., 19-33, 2003. CRC Press, Boca Ratón, Florida. Acknowledgements First author acknowledges the financial support obtained from Soil Imaging Laboratory (University of Gueplh, Canada) in 2014.

  10. Evaluation and management of 2 ferocactus spines in the orbit.

    PubMed

    Russell, David J; Kim, Tim I; Kubis, Kenneth

    2013-01-01

    A 49-year-old woman, who had fallen face first in a cactus 1 week earlier, presented with a small, mobile, noninflamed subcutaneous nodule at the rim of her right lateral orbit with no other functional deficits. A CT scan was obtained, which revealed a 4-cm intraorbital tubular-shaped foreign body resembling a large cactus spine. A second preoperative CT scan, obtained for an intraoperative guidance system, demonstrated a second cactus spine, which was initially not seen on the first CT scan. Both spines were removed surgically without complication. The authors discuss factors that can cause diagnosis delay, review the radiographic features of cactus spines, and discuss the often times benign clinical course of retained cactus spine foreign bodies. To the authors' knowledge, this is the first case report of cactus spines in the orbit. Health-care professionals should have a low threshold for imaging in cases of traumatic injuries involving cactus spines.

  11. Repeatability of Quantitative Whole-Body 18F-FDG PET/CT Uptake Measures as Function of Uptake Interval and Lesion Selection in Non-Small Cell Lung Cancer Patients.

    PubMed

    Kramer, Gerbrand Maria; Frings, Virginie; Hoetjes, Nikie; Hoekstra, Otto S; Smit, Egbert F; de Langen, Adrianus Johannes; Boellaard, Ronald

    2016-09-01

    Change in (18)F-FDG uptake may predict response to anticancer treatment. The PERCIST suggest a threshold of 30% change in SUV to define partial response and progressive disease. Evidence underlying these thresholds consists of mixed stand-alone PET and PET/CT data with variable uptake intervals and no consensus on the number of lesions to be assessed. Additionally, there is increasing interest in alternative (18)F-FDG uptake measures such as metabolically active tumor volume and total lesion glycolysis (TLG). The aim of this study was to comprehensively investigate the repeatability of various quantitative whole-body (18)F-FDG metrics in non-small cell lung cancer (NSCLC) patients as a function of tracer uptake interval and lesion selection strategies. Eleven NSCLC patients, with at least 1 intrathoracic lesion 3 cm or greater, underwent double baseline whole-body (18)F-FDG PET/CT scans at 60 and 90 min after injection within 3 d. All (18)F-FDG-avid tumors were delineated with an 50% threshold of SUVpeak adapted for local background. SUVmax, SUVmean, SUVpeak, TLG, metabolically active tumor volume, and tumor-to-blood and -liver ratios were evaluated, as well as the influence of lesion selection and 2 methods for correction of uptake time differences. The best repeatability was found using the SUV metrics of the averaged PERCIST target lesions (repeatability coefficients < 10%). The correlation between test and retest scans was strong for all uptake measures at either uptake interval (intraclass correlation coefficient > 0.97 and R(2) > 0.98). There were no significant differences in repeatability between data obtained 60 and 90 min after injection. When only PERCIST-defined target lesions were included (n = 34), repeatability improved for all uptake values. Normalization to liver or blood uptake or glucose correction did not improve repeatability. However, after correction for uptake time the correlation of SUV measures and TLG between the 60- and 90-min data significantly improved without affecting test-retest performance. This study suggests that a 15% change of SUVmean/SUVpeak at 60 min after injection can be used to assess response in advanced NSCLC patients if up to 5 PERCIST target lesions are assessed. Lower thresholds could be used in averaged PERCIST target lesions (<10%). © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Crossing Critical Thresholds at the Bob Steele Reading Center: Transforming Potentiality into Actuality.

    ERIC Educational Resources Information Center

    Demetrion, George

    The Bob Steele Reading Center was established in Hartford, Connecticut, in 1986 under board and staff leadership of the Literacy Volunteers of America-Connecticut (LVA-CT). The center has been under the management of Literacy Volunteers of Greater Hartford (LVGH) since 1989. Located in an alternative high school in a predominantly Hispanic…

  13. [Correlation of perceptive temperature threshold of oral mucosa and sympathetic skin response].

    PubMed

    Wang, Z G; Dong, T Z; Li, J; Chen, G

    2018-02-09

    Objectives: To explore the critical values of temperature perception in various mucosa sites of oral cavity and to draw the perceptive temperature threshold maps in healthy volunteers. To observe the interrelationship between subjective cognitive perception and sympathetic skin response (SSR) under various levels of thermal stimuli. Methods: Forty-two healthy volunteers (recruited from the students of Tianjin Medical University, 16 females and 26 males) were enrolled in the present study. The whole oral mucosa of each subject was divided into multiple partitions according to the mucosa type as well as tooth position. Peltier patch (commodity name) semiconductor chip was placed in the central part of each subarea of the mucosa. The stimulus was increased or decreased at 1 ℃ each time from a baseline temperature of 37 ℃. Warm (WT) and cold (CT) perception thresholds were measured thereafter respectively. A topographic temperature map of the oral mucosa for each subject was drew. Furthermore, the SSR was elicited and recorded at three temperature levels of 50 ℃, 55 ℃, 60 ℃ respectively. Analog test with visual analogue scale (VAS) and McGill scales were also performed. Data were statistically analyzed with variance and generalized estimation equation. Results: The tip of the tongue was the most sensitive area with both WT [(38.8±2.1) ℃, P< 0.05] and CT [(23.5±4.2) ℃, P< 0.05]. The highest heat threshold of gingival mucosa was in the left lower posterior teeth area [(49.9±3.7) ℃, P< 0.05], and the highest cold threshold of gingival mucosa was in the left upper posterior teeth area [(15.9±5.5) ℃, P< 0.05]. The perceptive temperature threshold increased gradually from the midline to both left and right sides were observed symmetrically and bilaterally. There was no statistically significant differences in temperature perception threshold between males and females [WT, male (44.8±3.1) ℃, female (44.8±3.2) ℃, OR= 1.100, P= 0.930; CT, Male (18.4±4.9) ℃, female (20.8±4.8) ℃, OR= 0.157, P= 0.210]. The SSR amplitude at sites of the tongue tip and the lower lip were increased with the rise of temperature [tongue tip (4.58±4.04) mv, P< 0.05, lower lip (2.89±3.01) mv, P< 0.05]. However, SSR amplitude values had no significant differences between males and females [tongue tip, male (2.00±2.16) mv, female (1.89±1.20) mv, P= 0.890; lower lip, male (0.94±0.82) mv, female (0.85±0.68) mv, P= 0.887]. Nevertheless, the amplitude of SSR and the VAS score of subjects showed a similar trend. Conclusions: The temperature perception levels were different amongst sites of lip, buccal mucosa, tongue dorsal mucosa and gingival mucosa. SSR amplitude values could reflect the responses of the mouth to the thermal stimuli.

  14. Processing of CT sinograms acquired using a VRX detector

    NASA Astrophysics Data System (ADS)

    Jordan, Lawrence M.; DiBianca, Frank A.; Zou, Ping; Laughter, Joseph S.; Zeman, Herbert D.

    2000-04-01

    A 'variable resolution x-ray detector' (VRX) capable of resolving beyond 100 cycles/main a single dimension has been proposed by DiBianca, et al. The use of detectors of this design for computed-tomography (CT) imaging requires novel preprocessing of data to correct for the detector's non- uniform imaging characteristics over its range of view. This paper describes algorithms developed specifically to adjust VRX data for varying magnification, source-to-detector range and beam obliquity and to sharpen reconstructions by deconvolving the ray impulse function. The preprocessing also incorporates nonlinear interpolation of VRX raw data into canonical CT sinogram formats.

  15. Dynamics of Perceived Exertion in Constant-Power Cycling: Time- and Workload-Dependent Thresholds

    ERIC Educational Resources Information Center

    Balagué, Natàlia; Hristovski, Robert; García, Sergi; Aguirre, Cecilia; Vázquez, Pablo; Razon, Selen; Tenenbaum, Gershon

    2015-01-01

    Purpose: The purpose of this study was to test the dynamics of perceived exertion shifts (PES) as a function of time and workload during constant-power cycling. Method: Fifty-two participants assigned to 4 groups performed a cycling task at 4 different constant workloads corresponding to their individual rates of perceived exertion (RPEs = 13, 15,…

  16. 75 FR 57696 - Change to FMCSA Policy on Calculating and Publicizing the Driver, Vehicle, and Hazardous...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-22

    ... document revises the date used to calculate the threshold crash and OOS rates, from calendar year cycles to fiscal year cycles, from October 1 of a given year to September 30 of the following year. This will... determine HMSP eligibility, before the motor carrier HMSP registration cycle begins on January 1. DATES...

  17. Interlaminar shear fracture toughness and fatigue thresholds for composite materials

    NASA Technical Reports Server (NTRS)

    Obrien, T. Kevin; Murri, Gretchen B.; Salpekar, Satish A.

    1987-01-01

    Static and cyclic end notched flexure tests were conducted on a graphite epoxy, a glass epoxy, and graphite thermoplastic to determine their interlaminar shear fracture toughness and fatigue thresholds for delamination in terms of limiting values of the mode II strain energy release rate, G-II, for delamination growth. The influence of precracking and data reduction schemes are discussed. Finite element analysis indicated that the beam theory calculation for G-II with the transverse shear contribution included was reasonably accurate over the entire range of crack lengths. Cyclic loading significantly reduced the critical G-II for delamination. A threshold value of the maximum cyclic G-II below which no delamination occurred after one million cycles was identified for each material. Also, residual static toughness tests were conducted on glass epoxy specimens that had undergone one million cycles without delamination. A linear mixed-mode delamination criteria was used to characterize the static toughness of several composite materials; however, a total G threshold criterion appears to characterize the fatigue delamination durability of composite materials with a wide range of static toughness.

  18. Breast density quantification with cone-beam CT: A post-mortem study

    PubMed Central

    Johnson, Travis; Ding, Huanjun; Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee

    2014-01-01

    Forty post-mortem breasts were imaged with a flat-panel based cone-beam x-ray CT system at 50 kVp. The feasibility of breast density quantification has been investigated using standard histogram thresholding and an automatic segmentation method based on the fuzzy c-means algorithm (FCM). The breasts were chemically decomposed into water, lipid, and protein immediately after image acquisition was completed. The percent fibroglandular volume (%FGV) from chemical analysis was used as the gold standard for breast density comparison. Both image-based segmentation techniques showed good precision in breast density quantification with high linear coefficients between the right and left breast of each pair. When comparing with the gold standard using %FGV from chemical analysis, Pearson’s r-values were estimated to be 0.983 and 0.968 for the FCM clustering and the histogram thresholding techniques, respectively. The standard error of the estimate (SEE) was also reduced from 3.92% to 2.45% by applying the automatic clustering technique. The results of the postmortem study suggested that breast tissue can be characterized in terms of water, lipid and protein contents with high accuracy by using chemical analysis, which offers a gold standard for breast density studies comparing different techniques. In the investigated image segmentation techniques, the FCM algorithm had high precision and accuracy in breast density quantification. In comparison to conventional histogram thresholding, it was more efficient and reduced inter-observer variation. PMID:24254317

  19. Dual energy CT kidney stone differentiation in photon counting computed tomography

    NASA Astrophysics Data System (ADS)

    Gutjahr, R.; Polster, C.; Henning, A.; Kappler, S.; Leng, S.; McCollough, C. H.; Sedlmair, M. U.; Schmidt, B.; Krauss, B.; Flohr, T. G.

    2017-03-01

    This study evaluates the capabilities of a whole-body photon counting CT system to differentiate between four common kidney stone materials, namely uric acid (UA), calcium oxalate monohydrate (COM), cystine (CYS), and apatite (APA) ex vivo. Two different x-ray spectra (120 kV and 140 kV) were applied and two acquisition modes were investigated. The macro-mode generates two energy threshold based image-volumes and two energy bin based image-volumes. In the chesspattern-mode four energy thresholds are applied. A virtual low energy image, as well as a virtual high energy image are derived from initial threshold-based images, while considering their statistically correlated nature. The energy bin based images of the macro-mode, as well as the virtual low and high energy image of the chesspattern-mode serve as input for our dual energy evaluation. The dual energy ratio of the individually segmented kidney stones were utilized to quantify the discriminability of the different materials. The dual energy ratios of the two acquisition modes showed high correlation for both applied spectra. Wilcoxon-rank sum tests and the evaluation of the area under the receiver operating characteristics curves suggest that the UA kidney stones are best differentiable from all other materials (AUC = 1.0), followed by CYS (AUC ≍ 0.9 compared against COM and APA). COM and APA, however, are hardly distinguishable (AUC between 0.63 and 0.76). The results hold true for the measurements of both spectra and both acquisition modes.

  20. Variational-based segmentation of bio-pores in tomographic images

    NASA Astrophysics Data System (ADS)

    Bauer, Benjamin; Cai, Xiaohao; Peth, Stephan; Schladitz, Katja; Steidl, Gabriele

    2017-01-01

    X-ray computed tomography (CT) combined with a quantitative analysis of the resulting volume images is a fruitful technique in soil science. However, the variations in X-ray attenuation due to different soil components keep the segmentation of single components within these highly heterogeneous samples a challenging problem. Particularly demanding are bio-pores due to their elongated shape and the low gray value difference to the surrounding soil structure. Recently, variational models in connection with algorithms from convex optimization were successfully applied for image segmentation. In this paper we apply these methods for the first time for the segmentation of bio-pores in CT images of soil samples. We introduce a novel convex model which enforces smooth boundaries of bio-pores and takes the varying attenuation values in the depth into account. Segmentation results are reported for different real-world 3D data sets as well as for simulated data. These results are compared with two gray value thresholding methods, namely indicator kriging and a global thresholding procedure, and with a morphological approach. Pros and cons of the methods are assessed by considering geometric features of the segmented bio-pore systems. The variational approach features well-connected smooth pores while not detecting smaller or shallower pores. This is an advantage in cases where the main bio-pores network is of interest and where infillings, e.g., excrements of earthworms, would result in losing pore connections as observed for the other thresholding methods.

  1. 18F-FDG PET/CT for Monitoring Response of Merkel Cell Carcinoma to the Novel Programmed Cell Death Ligand 1 Inhibitor Avelumab.

    PubMed

    Eshghi, Naghmehossadat; Lundeen, Tamara F; MacKinnon, Lea; Avery, Ryan; Kuo, Phillip H

    2018-05-01

    An 85-year-old man with stage IIIA Merkel cell carcinoma of the left arm was initially treated with local excision and axillary node dissection followed by radiation therapy. Eight months after surgery, whole-body FDG PET/CT demonstrated intensely hypermetabolic hepatic metastases and abdominal lymphadenopathy. Given his age and comorbidities, he was considered a poor candidate for chemotherapy, and therefore the novel programmed cell death ligand 1 inhibitor avelumab was initiated. FDG PET/CT after 4 cycles showed complete resolution of hepatic and nodal metastases. Whole-body FDG PET/CT can be used for monitoring response of multisystem metastases from Merkel cell carcinoma to active immunotherapy.

  2. SU-C-17A-01: MRI-Based Radiotherapy Treatment Planning In Pelvis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, S; Cao, Y; Jolly, S

    2014-06-15

    Purpose: To support radiotherapy dose calculation, synthetic CT (MRCT) image volumes need to represent the electron density of tissues with sufficient accuracy. This study compares CT and MRCT for pelvic radiotherapy. Methods: CT and multi-contrast MRI acquired using T1- based Dixon, T2 TSE, and PETRA sequences were acquired on an IRBapproved protocol patient. A previously published method was used to create a MRCT image volume by applying fuzzy classification on T1- weighted and calculated water image volumes (air and fluid voxels were excluded using thresholds applied to PETRA and T2-weighted images). The correlation of pelvic bone intensity between CT andmore » MRCT was investigated. Two treatment plans, based on CT and MRCT, were performed to mimic treatment for: (a) pelvic bone metastasis with a 16MV parallel beam arrangement, and (b) gynecological cancer with 6MV volumetric modulated arc therapy (VMAT) using two full arcs. The CT-calculated fluence maps were used to recalculate doses using the MRCT-derived density grid. The dose-volume histograms and dose distributions were compared. Results: Bone intensities in the MRCT volume correlated linearly with CT intensities up to 800 HU (containing 96% of the bone volume), and then decreased with CT intensity increase (4% volume). There was no significant difference in dose distributions between CT- and MRCTbased plans, except for the rectum and bladder, for which the V45 differed by 15% and 9%, respectively. These differences may be attributed to normal and visualized organ movement and volume variations between CT and MR scans. Conclusion: While MRCT had lower bone intensity in highly-dense bone, this did not cause significant dose deviations from CT due to its small percentage of volume. These results indicate that treatment planning using MRCT could generate comparable dose distributions to that using CT, and further demonstrate the feasibility of using MRI-alone to support Radiation Oncology workflow. NIH R01EB016079.« less

  3. Comparative characteristics of quantitative indexes for 18F-FDG uptake and metabolic volume in sequentially obtained PET/MRI and PET/CT.

    PubMed

    Lee, Soo Jin; Paeng, Jin Chul; Goo, Jin Mo; Lee, Jeong Min; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June-Key; Kang, Keon Wook

    2017-04-01

    The purpose of this study was to compare quantitative indexes for fluorine-18 fluorodeoxyglucose uptake and metabolic volume between PET/MRI and PET/CT. Sixty-six patients with solid tumors (32 with lung cancer and 34 with pancreatic cancer) who underwent sequential fluorine-18 fluorodeoxyglucose PET/MRI and PET/CT were retrospectively enrolled. On PET images, maximum and peak standardized uptake values (SUVmax and SUVpeak, respectively), and maximum tumor-to-liver ratio (TLRmax) were measured. Metabolic tumor volume (MTV) and total-lesion glycolysis (TLG) with margin thresholds of 50% SUVmax and SUV 2.5 (MTV50%, MTV2.5; TLG50%, TLG2.5, respectively) were compared between PET/MRI and PET/CT, with patients classified into two groups using imaging protocol (the PET/MRI-first and PET/CT-first groups). There were significant correlations of all tested indexes between PET/MRI and PET/CT (r=0.867-0.987, P<0.001). SUVmax and SUVpeak were lower on PET/MRI regardless of imaging protocol (P<0.001 in the PET/MRI-first group). In contrast, TLRmax exhibited reverse results between the PET/MRI-first and PET/CT-first groups. MTV50% and TLG values varied between PET/MRI and PET/CT, as well as between the PET/MRI-first and PET/CT-first groups. However, MTV2.5 was relatively robust against imaging protocol and modality. There are significant correlations of the quantitative indexes between PET/MRI and PET/CT. However, uptake indexes of SUVmax and SUVpeak are lower on PET/MRI than on PET/CT, and volumetric indexes of MTV50% and TLG values also exhibited significant differences. It may be suggested that TLRmax and MTV2.5 are relatively more appropriate indexes than others when PET/MRI and PET/CT are used interchangeably.

  4. Feasibility of MR-only proton dose calculations for prostate cancer radiotherapy using a commercial pseudo-CT generation method

    NASA Astrophysics Data System (ADS)

    Maspero, Matteo; van den Berg, Cornelis A. T.; Landry, Guillaume; Belka, Claus; Parodi, Katia; Seevinck, Peter R.; Raaymakers, Bas W.; Kurz, Christopher

    2017-12-01

    A magnetic resonance (MR)-only radiotherapy workflow can reduce cost, radiation exposure and uncertainties introduced by CT-MRI registration. A crucial prerequisite is generating the so called pseudo-CT (pCT) images for accurate dose calculation and planning. Many pCT generation methods have been proposed in the scope of photon radiotherapy. This work aims at verifying for the first time whether a commercially available photon-oriented pCT generation method can be employed for accurate intensity-modulated proton therapy (IMPT) dose calculation. A retrospective study was conducted on ten prostate cancer patients. For pCT generation from MR images, a commercial solution for creating bulk-assigned pCTs, called MR for Attenuation Correction (MRCAT), was employed. The assigned pseudo-Hounsfield Unit (HU) values were adapted to yield an increased agreement to the reference CT in terms of proton range. Internal air cavities were copied from the CT to minimise inter-scan differences. CT- and MRCAT-based dose calculations for opposing beam IMPT plans were compared by gamma analysis and evaluation of clinically relevant target and organ at risk dose volume histogram (DVH) parameters. The proton range in beam’s eye view (BEV) was compared using single field uniform dose (SFUD) plans. On average, a (2%, 2 mm) gamma pass rate of 98.4% was obtained using a 10% dose threshold after adaptation of the pseudo-HU values. Mean differences between CT- and MRCAT-based dose in the DVH parameters were below 1 Gy (<1.5% ). The median proton range difference was 0.1 mm, with on average 96% of all BEV dose profiles showing a range agreement better than 3 mm. Results suggest that accurate MR-based proton dose calculation using an automatic commercial bulk-assignment pCT generation method, originally designed for photon radiotherapy, is feasible following adaptation of the assigned pseudo-HU values.

  5. Beam hardening correction in CT myocardial perfusion measurement

    NASA Astrophysics Data System (ADS)

    So, Aaron; Hsieh, Jiang; Li, Jian-Ying; Lee, Ting-Yim

    2009-05-01

    This paper presents a method for correcting beam hardening (BH) in cardiac CT perfusion imaging. The proposed algorithm works with reconstructed images instead of projection data. It applies thresholds to separate low (soft tissue) and high (bone and contrast) attenuating material in a CT image. The BH error in each projection is estimated by a polynomial function of the forward projection of the segmented image. The error image is reconstructed by back-projection of the estimated errors. A BH-corrected image is then obtained by subtracting a scaled error image from the original image. Phantoms were designed to simulate the BH artifacts encountered in cardiac CT perfusion studies of humans and animals that are most commonly used in cardiac research. These phantoms were used to investigate whether BH artifacts can be reduced with our approach and to determine the optimal settings, which depend upon the anatomy of the scanned subject, of the correction algorithm for patient and animal studies. The correction algorithm was also applied to correct BH in a clinical study to further demonstrate the effectiveness of our technique.

  6. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    PubMed

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  7. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  8. Simulating the nasal cycle with computational fluid dynamics

    PubMed Central

    Patel, Ruchin G.; Garcia, Guilherme J. M.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.

    2015-01-01

    Objectives (1) Develop a method to account for the confounding effect of the nasal cycle when comparing pre- and post-surgery objective measures of nasal patency. (2) Illustrate this method by reporting objective measures derived from computational fluid dynamics (CFD) models spanning the full range of mucosal engorgement associated with the nasal cycle in two subjects. Study Design Retrospective Setting Academic tertiary medical center. Subjects and Methods A cohort of 24 nasal airway obstruction patients was reviewed to select the two patients with the greatest reciprocal change in mucosal engorgement between pre- and post-surgery computed tomography (CT) scans. Three-dimensional anatomic models were created based on the pre- and post-operative CT scans. Nasal cycling models were also created by gradually changing the thickness of the inferior turbinate, middle turbinate, and septal swell body. CFD was used to simulate airflow and to calculate nasal resistance and average heat flux. Results Before accounting for the nasal cycle, Patient A appeared to have a paradoxical worsening nasal obstruction in the right cavity postoperatively. After accounting for the nasal cycle, Patient A had small improvements in objective measures postoperatively. The magnitude of the surgical effect also differed in Patient B after accounting for the nasal cycle. Conclusion By simulating the nasal cycle and comparing models in similar congestive states, surgical changes in nasal patency can be distinguished from physiological changes associated with the nasal cycle. This ability can lead to more precise comparisons of pre and post-surgery objective measures and potentially more accurate virtual surgery planning. PMID:25450411

  9. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, S; Wang, Y; Weng, H

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiationmore » dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.« less

  10. Proton range shift analysis on brain pseudo-CT generated from T1 and T2 MR.

    PubMed

    Pileggi, Giampaolo; Speier, Christoph; Sharp, Gregory C; Izquierdo Garcia, David; Catana, Ciprian; Pursley, Jennifer; Amato, Francesco; Seco, Joao; Spadea, Maria Francesca

    2018-05-29

    In radiotherapy, MR imaging is only used because it has significantly better soft tissue contrast than CT, but it lacks electron density information needed for dose calculation. This work assesses the feasibility of using pseudo-CT (pCT) generated from T1w/T2w MR for proton treatment planning, where proton range comparisons are performed between standard CT and pCT. MR and CT data from 14 glioblastoma patients were used in this study. The pCT was generated by using conversion libraries obtained from tissue segmentation and anatomical regioning of the T1w/T2w MR. For each patient, a plan consisting of three 18 Gy beams was designed on the pCT, for a total of 42 analyzed beams. The plan was then transferred onto the CT that represented the ground truth. Range shift (RS) between pCT and CT was computed at R 80 over 10 slices. The acceptance threshold for RS was according to clinical guidelines of two institutions. A γ-index test was also performed on the total dose for each patient. Mean absolute error and bias for the pCT were 124 ± 10 and -16 ± 26 Hounsfield Units (HU), respectively. The median and interquartile range of RS was 0.5 and 1.4 mm, with highest absolute value being 4.4 mm. Of the 42 beams, 40 showed RS less than the clinical range margin. The two beams with larger RS were both in the cranio-caudal direction and had segmentation errors due to the partial volume effect, leading to misassignment of the HU. This study showed the feasibility of using T1w and T2w MRI to generate a pCT for proton therapy treatment, thus avoiding the use of a planning CT and allowing better target definition and possibilities for online adaptive therapies. Further improvements of the methodology are still required to improve the conversion from MRI intensities to HUs.

  11. Radiology metrics for safe use and regulatory compliance with CT imaging

    NASA Astrophysics Data System (ADS)

    Paden, Robert; Pavlicek, William

    2018-03-01

    The MACRA Act creates a Merit-Based Payment System, with monitoring patient exposure from CT providing one possible quality metric for meeting merit requirements. Quality metrics are also required by The Joint Commission, ACR, and CMS as facilities are tasked to perform reviews of CT irradiation events outside of expected ranges, review protocols for appropriateness, and validate parameters for low dose lung cancer screening. In order to efficiently collect and analyze irradiation events and associated DICOM tags, all clinical CT devices were DICOM connected to a parser which extracted dose related information for storage into a database. Dose data from every exam is compared to the appropriate external standard exam type. AAPM recommended CTDIvol values for head and torso, adult and pediatrics, coronary and perfusion exams are used for this study. CT doses outside the expected range were automatically formatted into a report for analysis and review documentation. CT Technologist textual content, the reason for proceeding with an irradiation above the recommended threshold, is captured for inclusion in the follow up reviews by physics staff. The use of a knowledge based approach in labeling individual protocol and device settings is a practical solution resulting in efficiency of analysis and review. Manual methods would require approximately 150 person-hours for our facility, exclusive of travel time and independent of device availability. An efficiency of 89% time savings occurs through use of this informatics tool including a low dose CT comparison review and low dose lung cancer screening requirements set forth by CMS.

  12. Group-wise feature-based registration of CT and ultrasound images of spine

    NASA Astrophysics Data System (ADS)

    Rasoulian, Abtin; Mousavi, Parvin; Hedjazi Moghari, Mehdi; Foroughi, Pezhman; Abolmaesumi, Purang

    2010-02-01

    Registration of pre-operative CT and freehand intra-operative ultrasound of lumbar spine could aid surgeons in the spinal needle injection which is a common procedure for pain management. Patients are always in a supine position during the CT scan, and in the prone or sitting position during the intervention. This leads to a difference in the spinal curvature between the two imaging modalities, which means a single rigid registration cannot be used for all of the lumbar vertebrae. In this work, a method for group-wise registration of pre-operative CT and intra-operative freehand 2-D ultrasound images of the lumbar spine is presented. The approach utilizes a pointbased registration technique based on the unscented Kalman filter, taking as input segmented vertebrae surfaces in both CT and ultrasound data. Ultrasound images are automatically segmented using a dynamic programming approach, while the CT images are semi-automatically segmented using thresholding. Since the curvature of the spine is different between the pre-operative and the intra-operative data, the registration approach is designed to simultaneously align individual groups of points segmented from each vertebra in the two imaging modalities. A biomechanical model is used to constrain the vertebrae transformation parameters during the registration and to ensure convergence. The mean target registration error achieved for individual vertebrae on five spine phantoms generated from CT data of patients, is 2.47 mm with standard deviation of 1.14 mm.

  13. Tropical Cyclone Diurnal Cycle as Observed by TRMM

    NASA Technical Reports Server (NTRS)

    Leppert, Kenneth D., II; Cecil, D. J.

    2015-01-01

    Using infrared satellite data, previous work has shown a consistent diurnal cycle in the pattern of cold cloud tops around mature tropical cyclones. In particular, an increase in the coverage by cold cloud tops often occurs in the inner core of the storm around the time of sunset and subsequently propagates outward to several hundred kilometers over the course of the following day. This consistent cycle may have important implications for structure and intensity changes of tropical cyclones and the forecasting of such changes. Because infrared satellite measurements are primarily sensitive to cloud top, the goal of this study is to use passive and active microwave measurements from the Tropical Rainfall Measurement Mission (TRMM) Microwave Imager (TMI) and Precipitation Radar (PR), respectively, to examine and better understand the tropical cyclone diurnal cycle throughout a larger depth of the storm's clouds. The National Hurricane Center's best track dataset was used to extract all PR and TMI pixels within 1000 km of each tropical cyclone that occurred in the Atlantic basin between 1998-2011. Then the data was composited according to radius (100-km bins from 0-1000 km) and local standard time (LST; 3-hr bins). Specifically, PR composites involved finding the percentage of pixels with reflectivity greater than or equal to 20 dBZ at various heights (i.e., 2-14 km in increments of 2 km) as a function of radius and time. The 37- and 85- GHz TMI channels are especially sensitive to scattering by precipitation-sized ice in the mid to upper portions of clouds. Hence, the percentage of 37- and 85-GHz polarization corrected temperatures less than various thresholds were calculated using data from all storms as a function of radius and time. For 37 GHz, thresholds of 260 K, 265 K, 270 K, and 275 K were used, and for 85 GHz, thresholds of 200-270 K in increments of 10 K were utilized. Note that convection forced by the interactions of a tropical cyclone with land (e.g., due to frictional convergence) may disrupt the natural convective cycle of a cyclone. Hence, only data pertaining to storms whose centers were greater than 300 km from land were included in the composites. Early results suggest the presence of a diurnal cycle in the PR composites of all Atlantic basin tropical cyclones from a height of 2-12 km from approximately 0-400 km radius, but the cycle is most apparent above 6 km. At a height of 8 km, there is a peak (minimum) in the percentage of PR pixels greater than or equal to 20 dBZ near 0 (21) LST in the inner core with some indication that this signal propagates outward with time. In contrast, the 37- and 85-GHz composites show little indication of a diurnal cycle at any radii, regardless of the threshold used. Ongoing work with this project will involve sub-setting the composites according to storm intensity to see if the diurnal cycle varies with storm strength. Moderate to strong vertical wind shear often leads to asymmetries in tropical cyclone convection and may disrupt the cyclone's natural diurnal cycle. Therefore, wind shear thresholds will be applied to the composites to determine if the diurnal cycle becomes more apparent in a low shear environment. Finally, other work to be completed will involve developing composites for other tropical cyclone basins, including the East Pacific, Northwest Pacific, South Pacific, and Indian Ocean.

  14. Targeted overexpression of calcitonin in gonadotrophs of transgenic mice leads to chronic hypoprolactinemia.

    PubMed

    Yuan, Ren; Kulkarni, Trupti; Wei, Fu; Shah, Girish V

    2005-01-14

    It was previously shown that calcitonin-like pituitary peptide (pit-CT) is synthesized and secreted by gonadotrophs, and pit-CT inhibits PRL gene transcription and lactotroph cell proliferation. Present studies examined long-term consequences of pit-CT overexpression on the functioning of mouse anterior pituitary (AP) gland. Targeted overexpression of pit-CT in gonadotrophs of mouse pituitaries was achieved by generating mice overexpressing bovine luteinizing hormone (LH)-alpha subunit promoter-pit-CT cDNA transgene. Transgenic (pit-CT+) mice displayed chronic but selective overexpression of pit-CT in gonadotrophs. The mice also displayed a dramatic decline in PRL gene expression as assessed by PRL mRNA abundance, PRL immunohistochemistry (IHC) and serum PRL levels. LH secretion in pit-CT+ mice was also reduced, without any change in FSH secretion. Reproductive abnormalities such as prolonged estrous cycles, reduced pregnancy rate, delivery of smaller litters, increased neonatal mortality and deficient lactation were also observed. Administration of PRL during early pregnancy significantly increased the pregnancy rate and neonatal survival of newborns. These results demonstrate that overexpression of pit-CT leads to chronic hypoprolactinemia and reproductive dysfunction in female mice, and reinforces the possibility that gonadotroph-derived pit-CT is an important paracrine regulator of lactotroph function.

  15. Automatic segmentation of lung parenchyma based on curvature of ribs using HRCT images in scleroderma studies

    NASA Astrophysics Data System (ADS)

    Prasad, M. N.; Brown, M. S.; Ahmad, S.; Abtin, F.; Allen, J.; da Costa, I.; Kim, H. J.; McNitt-Gray, M. F.; Goldin, J. G.

    2008-03-01

    Segmentation of lungs in the setting of scleroderma is a major challenge in medical image analysis. Threshold based techniques tend to leave out lung regions that have increased attenuation, for example in the presence of interstitial lung disease or in noisy low dose CT scans. The purpose of this work is to perform segmentation of the lungs using a technique that selects an optimal threshold for a given scleroderma patient by comparing the curvature of the lung boundary to that of the ribs. Our approach is based on adaptive thresholding and it tries to exploit the fact that the curvature of the ribs and the curvature of the lung boundary are closely matched. At first, the ribs are segmented and a polynomial is used to represent the ribs' curvature. A threshold value to segment the lungs is selected iteratively such that the deviation of the lung boundary from the polynomial is minimized. A Naive Bayes classifier is used to build the model for selection of the best fitting lung boundary. The performance of the new technique was compared against a standard approach using a simple fixed threshold of -400HU followed by regiongrowing. The two techniques were evaluated against manual reference segmentations using a volumetric overlap fraction (VOF) and the adaptive threshold technique was found to be significantly better than the fixed threshold technique.

  16. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, W; Xue, M; Patel, K

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) andmore » the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.« less

  17. X-ray computed tomography comparison of individual and parallel assembled commercial lithium iron phosphate batteries at end of life after high rate cycling

    NASA Astrophysics Data System (ADS)

    Carter, Rachel; Huhman, Brett; Love, Corey T.; Zenyuk, Iryna V.

    2018-03-01

    X-ray computed tomography (X-ray CT) across multiple length scales is utilized for the first time to investigate the physical abuse of high C-rate pulsed discharge on cells wired individually and in parallel.. Manufactured lithium iron phosphate cells boasting high rate capability were pulse power tested in both wiring conditions with high discharge currents of 10C for a high number of cycles (up to 1200) until end of life (<80% of initial discharge capacity retained). The parallel assembly reached end of life more rapidly for reasons unknown prior to CT investigations. The investigation revealed evidence of overdischarge in the most degraded cell from the parallel assembly, compared to more traditional failure in the individual cell. The parallel-wired cell exhibited dissolution of copper from the anode current collector and subsequent deposition throughout the separator near the cathode of the cell. This overdischarge-induced copper deposition, notably impossible to confirm with other state of health (SOH) monitoring methods, is diagnosed using CT by rendering the interior current collector without harm or alteration to the active materials. Correlation of CT observations to the electrochemical pulse data from the parallel-wired cells reveals the risk of parallel wiring during high C-rate pulse discharge.

  18. [Detection of Plasmodium falciparum by using magnetic nanoparticles separation-based quantitative real-time PCR assay].

    PubMed

    Wang, Fei; Tian, Yin; Yang, Jing; Sun, Fu-Jun; Sun, Ning; Liu, Bi-Yong; Tian, Rui; Ge, Guang-Lu; Zou, Ming-qiang; Deng, Cong-liang; Liu, Yi

    2014-10-01

    To establish a magnetic nanoparticles separation-based quantitative real-time PCR (RT-PCR) assay for fast and accurate detection of Plasmodium falciparum and providing a technical support for improving the control and prevention of imported malaria. According to the conserved sequences of the P. falciparum genome 18SrRNA, the species-specific primers and probe were designed and synthetized. The RT-PCR was established by constructing the plasmid standard, fitting the standard curve and using magnetic nanoparticles separation. The sensitivity and specificity of the assay were evaluated. The relationship between the threshold cycle (Ct) and logarithm of initial templates copies was linear over a range of 2.5 x 10(1) to 2.5 x 10(8) copies/μl (R2 = 0.999). Among 13 subjects of entry frontier, a P. falciparum carrier with low load was detected by using the assay and none was detected with the conventional examinations (microscopic examinations and rapid tests). This assay shows a high sensitivity in detection of P. falciparum, with rapid and accurate characteristics, and is especially useful in diagnosis of P. falciparum infectors with low parasitaemia at entry-exit frontier ports.

  19. A rib-specific multimodal registration algorithm for fused unfolded rib visualization using PET/CT

    NASA Astrophysics Data System (ADS)

    Kaftan, Jens N.; Kopaczka, Marcin; Wimmer, Andreas; Platsch, Günther; Declerck, Jérôme

    2014-03-01

    Respiratory motion affects the alignment of PET and CT volumes from PET/CT examinations in a non-rigid manner. This becomes particularly apparent if reviewing fine anatomical structures such as ribs when assessing bone metastases, which frequently occur in many advanced cancers. To make this routine diagnostic task more efficient, a fused unfolded rib visualization for 18F-NaF PET/CT is presented. It allows to review the whole rib cage in a single image. This advanced visualization is enabled by a novel rib-specific registration algorithm that rigidly optimizes the local alignment of each individual rib in both modalities based on a matched filter response function. More specifically, rib centerlines are automatically extracted from CT and subsequently individually aligned to the corresponding bone-specific PET rib uptake pattern. The proposed method has been validated on 20 PET/CT scans acquired at different clinical sites. It has been demonstrated that the presented rib- specific registration method significantly improves the rib alignment without having to run complex deformable registration algorithms. At the same time, it guarantees that rib lesions are not further deformed, which may otherwise affect quantitative measurements such as SUVs. Considering clinically relevant distance thresholds, the centerline portion with good alignment compared to the ground truth improved from 60:6% to 86:7% after registration while approximately 98% can be still considered as acceptably aligned.

  20. Enumeration and targeted analysis of KRAS, BRAF and PIK3CA mutations in CTCs captured by a label-free platform: Comparison to ctDNA and tissue in metastatic colorectal cancer.

    PubMed

    Kidess-Sigal, Evelyn; Liu, Haiyan E; Triboulet, Melanie M; Che, James; Ramani, Vishnu C; Visser, Brendan C; Poultsides, George A; Longacre, Teri A; Marziali, Andre; Vysotskaia, Valentina; Wiggin, Matthew; Heirich, Kyra; Hanft, Violet; Keilholz, Ulrich; Tinhofer, Ingeborg; Norton, Jeffrey A; Lee, Mark; Sollier-Christen, Elodie; Jeffrey, Stefanie S

    2016-12-20

    Treatment of advanced colorectal cancer (CRC) requires multimodal therapeutic approaches and need for monitoring tumor plasticity. Liquid biopsy biomarkers, including CTCs and ctDNA, hold promise for evaluating treatment response in real-time and guiding therapeutic modifications. From 15 patients with advanced CRC undergoing liver metastasectomy with curative intent, we collected 41 blood samples at different time points before and after surgery for CTC isolation and quantification using label-free Vortex technology. For mutational profiling, KRAS, BRAF, and PIK3CA hotspot mutations were analyzed in CTCs and ctDNA from 23 samples, nine matched liver metastases and three primary tumor samples. Mutational patterns were compared. 80% of patient blood samples were positive for CTCs, using a healthy baseline value as threshold (0.4 CTCs/mL), and 81.4% of captured cells were EpCAM+ CTCs. At least one mutation was detected in 78% of our blood samples. Among 23 matched CTC and ctDNA samples, we found a concordance of 78.2% for KRAS, 73.9% for BRAF and 91.3% for PIK3CA mutations. In several cases, CTCs exhibited a mutation that was not detected in ctDNA, and vice versa. Complementary assessment of both CTCs and ctDNA appears advantageous to assess dynamic tumor profiles.

  1. The characterization of small hypoattenuating renal masses on contrast-enhanced CT☆

    PubMed Central

    Patel, Neesha S.; Poder, Liina; Wang, Zhen J.; Yeh, Benjamin M.; Qayyum, Aliya; Jin, Hua; Coakley, Fergus V.

    2011-01-01

    Purpose To determine if small hypoattenuating renal masses can be characterized as simple cysts or renal cell carcinomas on contrast-enhanced computed tomography (CT). Materials and methods We retrospectively identified 20 small (≤1.5 cm) hypoattenuating renal masses seen on contrast enhanced CT, consisting of 14 simple cysts and six renal cell carcinomas. Three independent readers recorded subjective visual impression (five-point scale from 1=definitely fluid to 5=definitely solid), CT attenuation, border (well circumscribed or ill defined), and shape (ovoid or irregular) for each lesion. Results The overall area under the receiver operator characteristic curves for subjective visual impression, CT attenuation, border, and shape were 0.97, 0.82, 0.59, and 0.55, respectively. Using dichotomized ratings (1–2=cyst and 3–5=carcinoma), subjective impression had a sensitivity and specificity of 100% and 79–100%, respectively, for the diagnosis of renal cell carcinoma. Using a threshold of 50 Hounsfield Units (HU) or more, CT attenuation had a sensitivity and specificity of 100% and 43–64%, respectively. Conclusion Small hypoattenuating renal masses can be characterized with reasonable accuracy by subjective impression and CT attenuation; lesions that appear solid on visual inspection or have an attenuation value of 50 HU or more are likely to be renal cell carcinoma. © 2009 Elsevier Inc. All rights reserved. PMID:19559352

  2. Applications of Micro-CT scanning in medicine and dentistry: Microstructural analyses of a Wistar Rat mandible and a urinary tract stone

    NASA Astrophysics Data System (ADS)

    Latief, F. D. E.; Sari, D. S.; Fitri, L. A.

    2017-08-01

    High-resolution tomographic imaging by means of x-ray micro-computed tomography (μCT) has been widely utilized for morphological evaluations in dentistry and medicine. The use of μCT follows a standard procedure: image acquisition, reconstruction, processing, evaluation using image analysis, and reporting of results. This paper discusses methods of μCT using a specific scanning device, the Bruker SkyScan 1173 High Energy Micro-CT. We present a description of the general workflow, information on terminology for the measured parameters and corresponding units, and further analyses that can potentially be conducted with this technology. Brief qualitative and quantitative analyses, including basic image processing (VOI selection and thresholding) and measurement of several morphometrical variables (total VOI volume, object volume, percentage of total volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity) were conducted on two samples, the mandible of a wistar rat and a urinary tract stone, to illustrate the abilities of this device and its accompanying software package. The results of these analyses for both samples are reported, along with a discussion of the types of analyses that are possible using digital images obtained with a μCT scanning device, paying particular attention to non-diagnostic ex vivo research applications.

  3. Yield of diagnostic procedures for invasive fungal infections in neutropenic febrile patients with chest computed tomography abnormalities.

    PubMed

    Ho, Dora Y; Lin, Margaret; Schaenman, Joanna; Rosso, Fernando; Leung, Ann N C; Coutre, Steven E; Sista, Ramachandra R; Montoya, Jose G

    2011-01-01

    Haematological patients with neutropenic fever are frequently evaluated with chest computed tomography (CT) to rule out invasive fungal infections (IFI). We retrospectively analysed data from 100 consecutive patients with neutropenic fever and abnormal chest CT from 1998 to 2005 to evaluate their chest CT findings and the yield of diagnostic approaches employed. For their initial CTs, 79% had nodular opacities, with 24.1% associated with the halo sign. Other common CT abnormalities included pleural effusions (48%), ground glass opacities (37%) and consolidation (31%). The CT findings led to a change in antifungal therapy in 54% of the patients. Fifty-six patients received diagnostic procedures, including 46 bronchoscopies, 25 lung biopsies and seven sinus biopsies, with a diagnostic yield for IFI of 12.8%, 35.0% and 83.3%, respectively. In conclusion, chest CT plays an important role in the evaluation of haematological patients with febrile neutropenia and often leads to a change in antimicrobial therapy. Pulmonary nodules are the most common radiological abnormality. Sinus or lung biopsies have a high-diagnostic yield for IFI as compared to bronchoscopy. Patients with IFI may not have sinus/chest symptoms, and thus, clinicians should have a low threshold for performing sinus/chest imaging, and if indicated and safe, a biopsy of the abnormal areas. © 2009 Blackwell Verlag GmbH.

  4. Some Further Evidence on the Rate of Return to Schooling and the Business Cycle.

    ERIC Educational Resources Information Center

    King, Randall H.

    1980-01-01

    The business cycle has a strong impact on calculated rates of return to schooling. Cross-sectional rates of return are positively related to the unemployment rate in the year the cross-section is taken. The sensitivity of the relationship was not found to be substantially different among the races. (CT)

  5. Cognitive Reserve in Dementia: Implications for Cognitive Training

    PubMed Central

    Mondini, Sara; Madella, Ileana; Zangrossi, Andrea; Bigolin, Angela; Tomasi, Claudia; Michieletto, Marta; Villani, Daniele; Di Giovanni, Giuseppina; Mapelli, Daniela

    2016-01-01

    Cognitive reserve (CR) is a potential mechanism to cope with brain damage. The aim of this study was to evaluate the effect of CR on a cognitive training (CT) in a group of patients with dementia. Eighty six participants with mild to moderate dementia were identified by their level of CR quantified by the CR Index questionnaire (CRIq) and underwent a cycle of CT. A global measure of cognition mini mental state examination (MMSE) was obtained before (T0) and after (T1) the training. Multiple linear regression analyses highlighted CR as a significant factor able to predict changes in cognitive performance after the CT. In particular, patients with lower CR benefited from a CT program more than those with high CR. These data show that CR can modulate the outcome of a CT program and that it should be considered as a predictive factor of neuropsychological rehabilitation training efficacy in people with dementia. PMID:27199734

  6. Effects of Temperature on the Histotripsy Intrinsic Threshold for Cavitation.

    PubMed

    Vlaisavljevich, Eli; Xu, Zhen; Maxwell, Adam; Mancia, Lauren; Zhang, Xi; Lin, Kuang-Wei; Duryea, Alexander; Sukovich, Jonathan; Hall, Tim; Johnsen, Eric; Cain, Charles

    2016-05-10

    Histotripsy is an ultrasound ablation method that depends on the initiation of a dense cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated that a cavitation cloud can be formed by a single acoustic pulse with one high amplitude negative cycle, when the negative pressure amplitude exceeds a threshold intrinsic to the medium. The intrinsic thresholds in soft tissues and tissue phantoms that are water-based are similar to the intrinsic threshold of water over an experimentally verified frequency range of 0.3-3 MHz. Previous work studying the histotripsy intrinsic threshold has been limited to experiments performed at room temperature (~20°C). In this study, we investigate the effects of temperature on the histotripsy intrinsic threshold in water, which is essential to accurately predict the intrinsic thresholds expected over the full range of in vivo therapeutic temperatures. Based on previous work studying the histotripsy intrinsic threshold and classical nucleation theory, we hypothesize that the intrinsic threshold will decrease with increasing temperature. To test this hypothesis, the intrinsic threshold in water was investigated both experimentally and theoretically. The probability of generating cavitation bubbles was measured by applying a single pulse with one high amplitude negative cycle at 1 MHz to distilled, degassed water at temperatures ranging from 10°C-90°C. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results indicate that the intrinsic threshold (the negative pressure at which the cavitation probability=0.5) significantly decreases with increasing temperature, showing a nearly linear decreasing trend from 29.8±0.4 MPa at 10˚C to 14.9±1.4 MPa at 90˚C. Overall, the results of this study support our hypothesis that the intrinsic threshold is highly dependent upon the temperature of the medium, which may allow for better predictions of cavitation generation at body temperature in vivo and at the elevated temperatures commonly seen in high intensity focused ultrasound (HIFU) regimes.

  7. Effects of Temperature on the Histotripsy Intrinsic Threshold for Cavitation

    PubMed Central

    Vlaisavljevich, Eli; Xu, Zhen; Maxwell, Adam; Mancia, Lauren; Zhang, Xi; Lin, Kuang-Wei; Duryea, Alexander; Sukovich, Jonathan; Hall, Tim; Johnsen, Eric; Cain, Charles

    2018-01-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a dense cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated that a cavitation cloud can be formed by a single acoustic pulse with one high amplitude negative cycle, when the negative pressure amplitude exceeds a threshold intrinsic to the medium. The intrinsic thresholds in soft tissues and tissue phantoms that are water-based are similar to the intrinsic threshold of water over an experimentally verified frequency range of 0.3–3 MHz. Previous work studying the histotripsy intrinsic threshold has been limited to experiments performed at room temperature (~ 20°C). In this study, we investigate the effects of temperature on the histotripsy intrinsic threshold in water, which is essential to accurately predict the intrinsic thresholds expected over the full range of in vivo therapeutic temperatures. Based on previous work studying the histotripsy intrinsic threshold and classical nucleation theory, we hypothesize that the intrinsic threshold will decrease with increasing temperature. To test this hypothesis, the intrinsic threshold in water was investigated both experimentally and theoretically. The probability of generating cavitation bubbles was measured by applying a single pulse with one high amplitude negative cycle at 1 MHz to distilled, degassed water at temperatures ranging from 10°C–90°C. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results indicate that the intrinsic threshold (the negative pressure at which the cavitation probability = 0.5) significantly decreases with increasing temperature, showing a nearly linear decreasing trend from 29.8±0.4 MPa at 10°C to 14.9±1.4 MPa at 90°C. Overall, the results of this study support our hypothesis that the intrinsic threshold is highly dependent upon the temperature of the medium, which may allow for better predictions of cavitation generation at body temperature in vivo and at the elevated temperatures commonly seen in high intensity focused ultrasound (HIFU) regimes. PMID:28113706

  8. Increased sensitivity of RT-PCR for Potato virus Y detection using RNA isolated by a procedure with differential centrifugation.

    PubMed

    Zhang, Jianhua; Nie, Xianzhou; Boquel, Sébastien; Al-Daoud, Fadi; Pelletier, Yvan

    2015-12-01

    The sensitivity of reverse transcription-polymerase chain reaction (RT-PCR) for virus detection is influenced by many factors such as specificity of primers and quality of templates. These factors become extremely important for successful detection when virus concentration is low. Total RNA isolated from Potato virus Y (PVY)-infected potato plants using the sodium sulfite RNA isolation method or RNeasy plant mini kit contains a high proportion of host RNA and may also contain trace amount of phenolic and polysaccharide residues, which may inhibit RT-PCR. The goal of this study was to enhance the sensitivity of PVY detection by reducing host RNA in the extract by differential centrifugation followed by extraction using an RNeasy mini kit (DCR method). One-step RT-PCR had relatively low amplification efficiency for PVY RNA when a high proportion of plant RNA was present. SYBR Green-based real time RT-PCR showed that the RNA isolated by the DCR method had a higher cycle threshold value (Ct) for the elongation factor 1-α mRNA (Ef1α) of potato than the Ct value of the RNA extracted using the RNeasy plant mini kit, indicating that the DCR method significantly reduced the proportion of potato RNA in the extract. The detectable amount of RNA extracted using the DCR method was <0.001ng when plant sap from 10 PVY-infected and PVY-free potato leaflets in a 1.5:100 fresh weight ratio was extracted, compared with 0.01 and 0.02ng of RNA using the RNeasy plant mini kit and sodium sulfite RNA isolation methods, respectively. Copyright © 2015. Published by Elsevier B.V.

  9. Rapid concentration and sensitive detection of hookworm ova from wastewater matrices using a real-time PCR method.

    PubMed

    Gyawali, P; Sidhu, J P S; Ahmed, W; Jagals, P; Toze, S

    2015-12-01

    The risk of human hookworm infections from land application of wastewater matrices could be high in regions with high hookworm prevalence. A rapid, sensitive and specific hookworm detection method from wastewater matrices is required in order to assess human health risks. Currently available methods used to identify hookworm ova to the species level are time consuming and lack accuracy. In this study, a real-time PCR method was developed for the rapid, sensitive and specific detection of canine hookworm (Ancylostoma caninum) ova from wastewater matrices. A. caninum was chosen because of its morphological similarity to the human hookworm (Ancylostoma duodenale and Necator americanus). The newly developed PCR method has high detection sensitivity with the ability to detect less than one A. caninum ova from 1 L of secondary treated wastewater at the mean threshold cycle (CT) values ranging from 30.1 to 34.3. The method is also able to detect four A. caninum ova from 1 L of raw wastewater and from ∼4 g of treated sludge with mean CT values ranging from 35.6 to 39.8 and 39.8 to 39.9, respectively. The better detection sensitivity obtained for secondary treated wastewater compared to raw wastewater and sludge samples could be attributed to sample turbidity. The proposed method appears to be rapid, sensitive and specific compared to traditional methods and has potential to aid in the public health risk assessment associated with land application of wastewater matrices. Furthermore, the method can be adapted to detect other helminth ova of interest from wastewater matrices. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  10. Comparative Evaluation of the Diagnostic Performance of the Prototype Cepheid GeneXpert Ebola Assay

    PubMed Central

    Jansen van Vuren, Petrus; Grobbelaar, Antoinette; Storm, Nadia; Conteh, Ousman; Konneh, Kelfala; Kamara, Abdul; Sanne, Ian

    2015-01-01

    The Ebola virus disease (EVD) outbreak in West Africa has highlighted an urgent need for point-of-care (POC) assays for the diagnosis of this devastating disease in resource-limited African countries. The diagnostic performance characteristics of a prototype Cepheid GeneXpert Ebola POC used to detect Ebola virus (EBOV) in stored serum and plasma samples collected from suspected EVD cases in Sierra Leone in 2014 and 2015 was evaluated. The GeneXpert Ebola POC is a self-contained single-cartridge automated system that targets the glycoprotein (GP) and nucleoprotein (NP) genes of EBOV and yields results within 90 min. Results from 281 patient samples were compared to the results of a TaqMan real-time reverse transcription-PCR (RT-PCR) targeting the polymerase gene and performed on two real-time PCR machines. Agreement between the three platforms was 100% at cycle threshold (CT) values of ≤34.99, but discordant results were noted between CT values of 35 and 45.The diagnostic sensitivity of the three platforms was 100% in 91 patient samples that were confirmed to be infectious by virus isolation. All three molecular platforms detected viral EBOV RNA in additional samples that did not contain viable EBOV. The analytical sensitivity of the GeneXpert Ebola POC for the detection of NP was higher, and comparable to that of polymerase gene detection, than that for the detection of GP when using a titrated laboratory stock of EBOV. There was no detectable cross-reactivity with other hemorrhagic fever viruses or arboviruses. The GeneXpert Ebola POC offers an easy to operate and sensitive diagnostic tool that can be used for the rapid screening of suspected EVD cases in treatment or in holding centers during EVD outbreaks. PMID:26637383

  11. Computer-aided detection of bladder mass within non-contrast-enhanced region of CT Urography (CTU)

    NASA Astrophysics Data System (ADS)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Zhou, Chuan

    2016-03-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). We have previously developed methods for detection of bladder masses within the contrast-enhanced region of the bladder. In this study, we investigated methods for detection of bladder masses within the non-contrast enhanced region. The bladder was first segmented using a newly developed deep-learning convolutional neural network in combination with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensityprojection- based method. The non-contrast region was smoothed and a gray level threshold was employed to segment the bladder wall and potential masses. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify lesion candidates as a prescreening step. The lesion candidates were segmented using our autoinitialized cascaded level set (AI-CALS) segmentation method, and 27 morphological features were extracted for each candidate. Stepwise feature selection with simplex optimization and leave-one-case-out resampling were used for training and validation of a false positive (FP) classifier. In each leave-one-case-out cycle, features were selected from the training cases and a linear discriminant analysis (LDA) classifier was designed to merge the selected features into a single score for classification of the left-out test case. A data set of 33 cases with 42 biopsy-proven lesions in the noncontrast enhanced region was collected. During prescreening, the system obtained 83.3% sensitivity at an average of 2.4 FPs/case. After feature extraction and FP reduction by LDA, the system achieved 81.0% sensitivity at 2.0 FPs/case, and 73.8% sensitivity at 1.5 FPs/case.

  12. 50. VIEW LOOKING SOUTHEAST AT A MOTORGENERATOR SET LOCATED UNDER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. VIEW LOOKING SOUTHEAST AT A MOTOR-GENERATOR SET LOCATED UNDER CONTROL ROOM. THREE 450 kva., 2500 VOLT, 60 CYCLE MOTOR-GENERATOR UNITS PROVIDED POWER FOR THE RAILROAD SIGNAL SYSTEM. 25 CYCLE POWER WAS PROVIDED TO THE MOTOR (LEFT BACKGROUND). THE MOTOR TURNED THE GENERATOR (CENTER FOREGROUND) WHICH PRODUCED 60 CYCLE POWER TO OPERATE LIGHTS AND SIGNALING DEVICES. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  13. Interobserver agreement of interim and end-of-treatment 18F-FDG PET/CT in diffuse large B-cell lymphoma (DLBCL): impact on clinical practice and trials.

    PubMed

    Burggraaff, Coreline N; Cornelisse, Alexander C; Hoekstra, Otto S; Lugtenburg, Pieternella J; de Keizer, Bart; Arens, Anne I J; Celik, Filiz; Huijbregts, Julia E; De Vet, Henrica C W; Zijlstra, Josee M

    2018-05-04

    We aimed to assess the interobserver agreement of Interim PET (I-PET) and End-of-Treatment PET (EoT-PET) using the Deauville 5-point scale (DS) in first-line DLBCL patients. Methods: I-PET and EoT-PET scans of DLBCL patients were performed in the HOVON84 study (2007-2012), an international multicenter randomized controlled trial. Patients received R-CHOP14 and were randomized to receive rituximab intensification in the first 4 cycles or not. I-PET was made after 4 cycles (for observational purposes), and EoT-PET scan after 6 or 8 cycles. Two independent central reviewers retrospectively scored all scans according to the DS-system, blinded to clinical outcomes. Results were dichotomised as 'negative' (DS: 1-3) or 'positive' (DS: 4-5). Besides percentage overall agreement we calculated agreement for positive and negative scores, expressed as positive agreement (PA) and negative agreement (NA), respectively. Results: 465 I-PET and 457 EoT-PET scans were centrally reviewed; baseline 18 F-FDG PET(/CT) was available in 75-77%, and CT in the remaining cases. Percentage overall agreement for I-PET and EoT-PET were 87.7% and 91.7% ( P =0.049), with NA of 92.0% and 95.0% ( P =0.091), and PA of 73.7% and 76.3% ( P =0.656), respectively. Conclusion: Interobserver agreement using DS in DLBCL patients in I-PET and EoT-PET yields high overall and negative agreement. The lower positive agreement suggests that EoT-PET/CT treatment evaluation in daily practice and I-PET adapted trials may benefit from dual reads and central review, respectively. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Computerized method for automatic evaluation of lean body mass from PET/CT: comparison with predictive equations.

    PubMed

    Chan, Tao

    2012-01-01

    CT has become an established method for calculating body composition, but it requires data from the whole body, which are not typically obtained in routine PET/CT examinations. A computerized scheme that evaluates whole-body lean body mass (LBM) based on CT data from limited-whole-body coverage was developed. The LBM so obtained was compared with results from conventional predictive equations. LBM can be obtained automatically from limited-whole-body CT data by 3 means: quantification of body composition from CT images in the limited-whole-body scan, based on thresholding of CT attenuation; determination of the range of coverage based on a characteristic trend of changing composition across different levels and pattern recognition of specific features at strategic positions; and estimation of the LBM of the whole body on the basis of a predetermined relationship between proportion of fat mass and extent of coverage. This scheme was validated using 18 whole-body PET/CT examinations truncated at different lengths to emulate limited-whole-body data. LBM was also calculated using predictive equations that had been reported for use in SUV normalization. LBM derived from limited-whole-body data using the proposed method correlated strongly with LBM derived from whole-body CT data, with correlation coefficients ranging from 0.991 (shorter coverage) to 0.998 (longer coverage) and SEMs of LBM ranging from 0.14 to 0.33 kg. These were more accurate than results from different predictive equations, which ranged in correlation coefficient from 0.635 to 0.970 and in SEM from 0.64 to 2.40 kg. LBM of the whole body could be automatically estimated from CT data of limited-whole-body coverage typically acquired in PET/CT examinations. This estimation allows more accurate and consistent quantification of metabolic activity of tumors based on LBM-normalized standardized uptake value.

  15. Development and validation of a prediction model for measurement variability of lung nodule volumetry in patients with pulmonary metastases.

    PubMed

    Hwang, Eui Jin; Goo, Jin Mo; Kim, Jihye; Park, Sang Joon; Ahn, Soyeon; Park, Chang Min; Shin, Yeong-Gil

    2017-08-01

    To develop a prediction model for the variability range of lung nodule volumetry and validate the model in detecting nodule growth. For model development, 50 patients with metastatic nodules were prospectively included. Two consecutive CT scans were performed to assess volumetry for 1,586 nodules. Nodule volume, surface voxel proportion (SVP), attachment proportion (AP) and absolute percentage error (APE) were calculated for each nodule and quantile regression analyses were performed to model the 95% percentile of APE. For validation, 41 patients who underwent metastasectomy were included. After volumetry of resected nodules, sensitivity and specificity for diagnosis of metastatic nodules were compared between two different thresholds of nodule growth determination: uniform 25% volume change threshold and individualized threshold calculated from the model (estimated 95% percentile APE). SVP and AP were included in the final model: Estimated 95% percentile APE = 37.82 · SVP + 48.60 · AP-10.87. In the validation session, the individualized threshold showed significantly higher sensitivity for diagnosis of metastatic nodules than the uniform 25% threshold (75.0% vs. 66.0%, P = 0.004) CONCLUSION: Estimated 95% percentile APE as an individualized threshold of nodule growth showed greater sensitivity in diagnosing metastatic nodules than a global 25% threshold. • The 95 % percentile APE of a particular nodule can be predicted. • Estimated 95 % percentile APE can be utilized as an individualized threshold. • More sensitive diagnosis of metastasis can be made with an individualized threshold. • Tailored nodule management can be provided during nodule growth follow-up.

  16. Reproducibility of image quality for moving objects using respiratory-gated computed tomography: a study using a phantom model

    PubMed Central

    Fukumitsu, Nobuyoshi; Ishida, Masaya; Terunuma, Toshiyuki; Mizumoto, Masashi; Hashimoto, Takayuki; Moritake, Takashi; Okumura, Toshiyuki; Sakae, Takeji; Tsuboi, Koji; Sakurai, Hideyuki

    2012-01-01

    To investigate the reproducibility of computed tomography (CT) imaging quality in respiratory-gated radiation treatment planning is essential in radiotherapy of movable tumors. Seven series of regular and six series of irregular respiratory motions were performed using a thorax dynamic phantom. For the regular respiratory motions, the respiratory cycle was changed from 2.5 to 4 s and the amplitude was changed from 4 to 10 mm. For the irregular respiratory motions, a cycle of 2.5 to 4 or an amplitude of 4 to 10 mm was added to the base data (i.e. 3.5-s cycle, 6-mm amplitude) every three cycles. Images of the object were acquired six times using respiratory-gated data acquisition. The volume of the object was calculated and the reproducibility of the volume was decided based on the variety. The registered image of the object was added and the reproducibility of the shape was decided based on the degree of overlap of objects. The variety in the volumes and shapes differed significantly as the respiratory cycle changed according to regular respiratory motions. In irregular respiratory motion, shape reproducibility was further inferior, and the percentage of overlap among the six images was 35.26% in the 2.5- and 3.5-s cycle mixed group. Amplitude changes did not produce significant differences in the variety of the volumes and shapes. Respiratory cycle changes reduced the reproducibility of the image quality in respiratory-gated CT. PMID:22966173

  17. Experimental Evaluation of a Deformable Registration Algorithm for Motion Correction in PET-CT Guided Biopsy.

    PubMed

    Khare, Rahul; Sala, Guillaume; Kinahan, Paul; Esposito, Giuseppe; Banovac, Filip; Cleary, Kevin; Enquobahrie, Andinet

    2013-01-01

    Positron emission tomography computed tomography (PET-CT) images are increasingly being used for guidance during percutaneous biopsy. However, due to the physics of image acquisition, PET-CT images are susceptible to problems due to respiratory and cardiac motion, leading to inaccurate tumor localization, shape distortion, and attenuation correction. To address these problems, we present a method for motion correction that relies on respiratory gated CT images aligned using a deformable registration algorithm. In this work, we use two deformable registration algorithms and two optimization approaches for registering the CT images obtained over the respiratory cycle. The two algorithms are the BSpline and the symmetric forces Demons registration. In the first optmization approach, CT images at each time point are registered to a single reference time point. In the second approach, deformation maps are obtained to align each CT time point with its adjacent time point. These deformations are then composed to find the deformation with respect to a reference time point. We evaluate these two algorithms and optimization approaches using respiratory gated CT images obtained from 7 patients. Our results show that overall the BSpline registration algorithm with the reference optimization approach gives the best results.

  18. Total protein of whole saliva as a biomarker of anaerobic threshold.

    PubMed

    Bortolini, Miguel Junior Sordi; De Agostini, Guilherme Gularte; Reis, Ismair Teodoro; Lamounier, Romeu Paulo Martins Silva; Blumberg, Jeffrey B; Espindola, Foued Salmen

    2009-09-01

    Saliva provides a convenient and noninvasive matrix for assessing specific physiological parameters, including some biomarkers of exercise. We investigated whether the total protein concentration of whole saliva (TPWS) would reflect the anaerobic threshold during an incremental exercise test. After a warm-up period, 13 nonsmoking men performed a maximum incremental exercise on a cycle ergometer. Blood and stimulated saliva were collected during the test. The TPWS anaerobic threshold (PAT) was determined using the Dmax method. The PAT was correlated with the blood lactate anaerobic threshold (AT; r = .93, p < .05). No significant difference (p = .16) was observed between PAT and AT. Thus, TPWS provides a convenient and noninvasive matrix for determining the anaerobic threshold during incremental exercise tests.

  19. Investigation of the accuracy of breast tissue segmentation methods for the purpose of developing breast deformation models for use in adaptive radiotherapy

    NASA Astrophysics Data System (ADS)

    Juneja, P.; Harris, E. J.; Evans, P. M.

    2014-03-01

    Realistic modelling of breast deformation requires the breast tissue to be segmented into fibroglandular and fatty tissue and assigned suitable material properties. There are a number of breast tissue segmentation methods proposed and used in the literature. The purpose of this study was to validate and compare the accuracy of various segmentation methods and to investigate the effect of the tissue distribution on the segmentation accuracy. Computed tomography (CT) data for 24 patients, both in supine and prone positions were segmented into fibroglandular and fatty tissue. The segmentation methods explored were: physical density thresholding; interactive thresholding; fuzzy c-means clustering (FCM) with three classes (FCM3) and four classes (FCM4); and k-means clustering. Validation was done in two-stages: firstly, a new approach, supine-prone validation based on the assumption that the breast composition should appear the same in the supine and prone scans was used. Secondly, outlines from three experts were used for validation. This study found that FCM3 gave the most accurate segmentation of breast tissue from CT data and that the segmentation accuracy is adversely affected by the sparseness of the fibroglandular tissue distribution.

  20. Zero-point Energy is Needed in Molecular Dynamics Calculations to Access the Saddle Point for H+HCN→H2CN* and cis/trans-HCNH* on a New Potential Energy Surface.

    PubMed

    Wang, Xiaohong; Bowman, Joel M

    2013-02-12

    We calculate the probabilities for the association reactions H+HCN→H2CN* and cis/trans-HCNH*, using quasiclassical trajectory (QCT) and classical trajectory (CT) calculations, on a new global ab initio potential energy surface (PES) for H2CN including the reaction channels. The surface is a linear least-squares fit of roughly 60 000 CCSD(T)-F12b/aug-cc-pVDZ electronic energies, using a permutationally invariant basis with Morse-type variables. The reaction probabilities are obtained at a variety of collision energies and impact parameters. Large differences in the threshold energies in the two types of dynamics calculations are traced to the absence of zero-point energy in the CT calculations. We argue that the QCT threshold energy is the realistic one. In addition, trajectories find a direct pathway to trans-HCNH, even though there is no obvious transition state (TS) for this pathway. Instead the saddle point (SP) for the addition to cis-HCNH is evidently also the TS for direct formation of trans-HCNH.

  1. Microcomputed tomography with a second generation photon-counting x-ray detector: contrast analysis and material separation

    NASA Astrophysics Data System (ADS)

    Wang, X.; Meier, D.; Oya, P.; Maehlum, G. E.; Wagenaar, D. J.; Tsui, B. M. W.; Patt, B. E.; Frey, E. C.

    2010-04-01

    The overall aim of this work was to evaluate the potential for improving in vivo small animal microCT through the use of an energy resolved photon-counting detector. To this end, we developed and evaluated a prototype microCT system based on a second-generation photon-counting x-ray detector which simultaneously counted photons with energies above six energy thresholds. First, we developed a threshold tuning procedure to reduce the dependence of detector uniformity and to reduce ring artifacts. Next, we evaluated the system in terms of the contrast-to-noise ratio in different energy windows for different target materials. These differences provided the possibility to weight the data acquired in different windows in order to optimize the contrast-to-noise ratio. We also explored the ability of the system to use data from different energy windows to aid in distinguishing various materials. We found that the energy discrimination capability provided the possibility for improved contrast-to-noise ratios and allowed separation of more than two materials, e.g., bone, soft-tissue and one or more contrast materials having K-absorption edges in the energy ranges of interest.

  2. Assessment of the spatial pattern of colorectal tumour perfusion estimated at perfusion CT using two-dimensional fractal analysis.

    PubMed

    Goh, Vicky; Sanghera, Bal; Wellsted, David M; Sundin, Josefin; Halligan, Steve

    2009-06-01

    The aim was to evaluate the feasibility of fractal analysis for assessing the spatial pattern of colorectal tumour perfusion at dynamic contrast-enhanced CT (perfusion CT). Twenty patients with colorectal adenocarcinoma underwent a 65-s perfusion CT study from which a perfusion parametric map was generated using validated commercial software. The tumour was identified by an experienced radiologist, segmented via thresholding and fractal analysis applied using in-house software: fractal dimension, abundance and lacunarity were assessed for the entire outlined tumour and for selected representative areas within the tumour of low and high perfusion. Comparison was made with ten patients with normal colons, processed in a similar manner, using two-way mixed analysis of variance with statistical significance at the 5% level. Fractal values were higher in cancer than normal colon (p < or = 0.001): mean (SD) 1.71 (0.07) versus 1.61 (0.07) for fractal dimension and 7.82 (0.62) and 6.89 (0.47) for fractal abundance. Fractal values were lower in 'high' than 'low' perfusion areas. Lacunarity curves were shifted to the right for cancer compared with normal colon. In conclusion, colorectal cancer mapped by perfusion CT demonstrates fractal properties. Fractal analysis is feasible, potentially providing a quantitative measure of the spatial pattern of tumour perfusion.

  3. Classification of CT examinations for COPD visual severity analysis

    NASA Astrophysics Data System (ADS)

    Tan, Jun; Zheng, Bin; Wang, Xingwei; Pu, Jiantao; Gur, David; Sciurba, Frank C.; Leader, J. Ken

    2012-03-01

    In this study we present a computational method of CT examination classification into visual assessed emphysema severity. The visual severity categories ranged from 0 to 5 and were rated by an experienced radiologist. The six categories were none, trace, mild, moderate, severe and very severe. Lung segmentation was performed for every input image and all image features are extracted from the segmented lung only. We adopted a two-level feature representation method for the classification. Five gray level distribution statistics, six gray level co-occurrence matrix (GLCM), and eleven gray level run-length (GLRL) features were computed for each CT image depicted segment lung. Then we used wavelets decomposition to obtain the low- and high-frequency components of the input image, and again extract from the lung region six GLCM features and eleven GLRL features. Therefore our feature vector length is 56. The CT examinations were classified using the support vector machine (SVM) and k-nearest neighbors (KNN) and the traditional threshold (density mask) approach. The SVM classifier had the highest classification performance of all the methods with an overall sensitivity of 54.4% and a 69.6% sensitivity to discriminate "no" and "trace visually assessed emphysema. We believe this work may lead to an automated, objective method to categorically classify emphysema severity on CT exam.

  4. CT findings of persistent pure ground glass opacity: can we predict the invasiveness?

    PubMed

    Liu, Li-Heng; Liu, Ming; Wei, Ran; Jin, Er-Hu; Liu, Yu-Hui; Xu, Liang; Li, Wen-Wu; Huang, Yong

    2015-01-01

    To investigate whether CT findings can predict the invasiveness of persistent cancerous pure ground glass opacity (pGGO) by correlating the CT imaging features of persistent pGGO with pathological changes. Ninety five patients with persistent pGGOs were included. Three radiologists evaluated the morphologic features of these pGGOs at high resolution CT (HRCT). Binary logistic regression was used to assess the association between CT findings and histopathological classification (pre-invasive and invasive groups). Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of diameters. A total of 105 pGGOs were identified. Between pre-invasive (atypical adenomatous hyperplasia, AAH, and adenocarcinoma in situ, AIS) and invasive group (minimally invasive adenocarcinoma, MIA and invasive lung adenocarcinomas, ILA), there were significant differences in diameter, spiculation and vessel dilatation (p<0.05). No difference was found in air-bronchogram, bubble- lucency, lobulated-margin, pleural indentation or vascular convergence (p>0.05). The optimal threshold value of the diameters to predict the invasiveness of pGGO was 12.50mm. HRCT features can predict the invasiveness of persistent pGGO. The pGGO with a diameter more than 12.50mm, presences of spiculation and vessel dilatation are important factors to differentiate invasive adenocarcinoma from pre-invasive cancerous lesions.

  5. A pore-scale study of fracture dynamics in rock using X-ray micro-CT under ambient freeze-thaw cycling.

    PubMed

    De Kock, Tim; Boone, Marijn A; De Schryver, Thomas; Van Stappen, Jeroen; Derluyn, Hannelore; Masschaele, Bert; De Schutter, Geert; Cnudde, Veerle

    2015-03-03

    Freeze-thaw cycling stresses many environments which include porous media such as soil, rock and concrete. Climate change can expose new regions and subject others to a changing freeze-thaw frequency. Therefore, understanding and predicting the effect of freeze-thaw cycles is important in environmental science, the built environment and cultural heritage preservation. In this paper, we explore the possibilities of state-of-the-art micro-CT in studying the pore scale dynamics related to freezing and thawing. The experiments show the development of a fracture network in a porous limestone when cooling to -9.7 °C, at which an exothermal temperature peak is a proxy for ice crystallization. The dynamics of the fracture network are visualized with a time frame of 80 s. Theoretical assumptions predict that crystallization in these experiments occurs in pores of 6-20.1 nm under transient conditions. Here, the crystallization-induced stress exceeds rock strength when the local crystal fraction in the pores is 4.3%. The location of fractures is strongly related to preferential water uptake paths and rock texture, which are visually identified. Laboratory, continuous X-ray micro-CT scanning opens new perspectives for the pore-scale study of ice crystallization in porous media as well as for environmental processes related to freeze-thaw fracturing.

  6. Cutaneous afferents mediating the cutaneous silent period in the upper limbs: evidences for a role of low-threshold sensory fibres.

    PubMed

    Serrao, M; Parisi, L; Pierelli, F; Rossi, P

    2001-11-01

    To evaluate the contribution of the low-threshold afferents to the production of the cutaneous silent period (CSP) in the upper limbs. The CSP was studied in 10 healthy adults and 4 patients with Friedreich's ataxia. The following neurophysiological aspects were studied: (a) relationship between sensory threshold (ST), sensory action potential (SAP) amplitude and CSP parameters; (b) habituation and recovery cycle of the CSP at different stimulus intensities (2xST and 8xST); (c) pattern of responses in distal and proximal muscles at different stimulus intensities (2xST and 8xST). (a) The CSP occurred at low intensities (1xST and 2xST) and increased abruptly between 3.5xST and 4xST (corresponding to the pain threshold). The SAP amplitude was saturated before CSP saturation. In the patients with Friedreich's ataxia, the CSP appeared only at higher stimulus intensities (6xST-8xST). (b) The CSP evoked at 2xST showed a fast habituation and slow recovery cycle whereas the opposite behaviour was found at 8xST. (c) Low-threshold stimuli induced an inhibitory response restricted to the distal muscles. High-intensity stimulation produced an electromyographic suppression, significantly increasing from proximal to distal muscles. Our findings support the notion that low-threshold afferents participate in the production of the CSP in the upper limbs. The different afferents may activate different central neural networks with separate functional significance.

  7. PET response assessment in apatinib-treated radioactive iodine-refractory thyroid cancer.

    PubMed

    Wang, Chen; Zhang, Xin; Yang, Xue; Li, Hui; Cui, Ruixue; Guan, Wenmin; Li, Xin; Zhu, Zhaohui; Lin, Yansong

    2018-06-01

    This work evaluated the use of the positron emission tomography (PET)/computed tomography (CT) technique to assess the early therapeutic response and predict the prognosis of patients with radioactive iodine-refractory differentiated thyroid cancer (RAIR-DTC) who underwent apatinib therapy. Standardised uptake value (SUV), metabolic tumour volume (MTV) and total lesion glycolysis (TLG), derived from 18 F-FDG PET/CT and SUV from 68 Ga-NOTA-PRGD2 PET/CT were evaluated. Tumour response was evaluated using the Response Evaluation Criteria in Solid Tumors (RECIST) 1.1. Sixteen of 20 patients achieved partial response (PR) and four of 20 had stable disease (SD) after apatinib therapy. Six progression-free survival (PFS) events occurred. A strong correlation was observed between the best change in the sum of the longest diameters of target lesions (ΔCT%) and 18 F-FDG PET/CT indices after the completion of the first treatment cycle (ΔMTV% ( P  = 0.0019), ΔTLG% ( P  = 0.0021) and ΔSUVmax% ( P  = 0.0443)). A significant difference in PFS was observed between patients with ΔMTV% <-45% and ≥-45% ( P  = 0.0019) and between patients with ΔTLG% <-80% and ≥-80% ( P  = 0.0065). Ten of 11 patients presented a decrease in SUVmax on 68 Ga-NOTA-PRGD2 PET/CT after two cycles of apatinib therapy and showed PR, whereas one patient presenting an increase in SUVmax only showed SD as the best response. When a cut-off value of the target/background ratio at -20% was used, two PFS curves showed a significant difference ( P  = 0.0016). Hence, early assessment by 18 F-FDG and 68 Ga-NOTA-PRGD2 PET/CT was effective in the prediction and evaluation of RAIR-DTC treated with apatinib. © 2018 Society for Endocrinology.

  8. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences.

    PubMed

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-02-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n = 15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 degrees for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9 +/- 3.1 mm vs 19.0 +/- 9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases.

  9. Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.

    PubMed

    Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari

    2014-07-01

    [Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.

  10. Residence time control on hot moments of net nitrate production and uptake in the hyporheic zone

    USGS Publications Warehouse

    Briggs, Martin A.; Lautz, Laura K.; Hare, Danielle K.

    2014-01-01

    moments of net production and uptake, enhancing NO3- production as residence times approach the anaerobic threshold, and changing zones of net NO3- production to uptake as residence times increase past the net sink threshold. The anaerobic and net sink thresholds for beaver-influenced streambed morphology occur at much shorter residence times (1.3 h and 2.3 h, respectively) compared to other documented hyporheic systems, and the net sink threshold compares favorably to the lower boundary of the anaerobic threshold determined for this system with the new oxygen Damkohler number. The consistency of the residence time threshold values of NO3- cycling in this study, despite environmental variability and disparate morphology, indicates that NO3- hot moment dynamics are primarily driven by changes in physical hydrology and associated residence times.

  11. Metabolic Tumor Volume and Total Lesion Glycolysis in Oropharyngeal Cancer Treated With Definitive Radiotherapy: Which Threshold Is the Best Predictor of Local Control?

    PubMed

    Castelli, Joël; Depeursinge, Adrien; de Bari, Berardino; Devillers, Anne; de Crevoisier, Renaud; Bourhis, Jean; Prior, John O

    2017-06-01

    In the context of oropharyngeal cancer treated with definitive radiotherapy, the aim of this retrospective study was to identify the best threshold value to compute metabolic tumor volume (MTV) and/or total lesion glycolysis to predict local-regional control (LRC) and disease-free survival. One hundred twenty patients with a locally advanced oropharyngeal cancer from 2 different institutions treated with definitive radiotherapy underwent FDG PET/CT before treatment. Various MTVs and total lesion glycolysis were defined based on 2 segmentation methods: (i) an absolute threshold of SUV (0-20 g/mL) or (ii) a relative threshold for SUVmax (0%-100%). The parameters' predictive capabilities for disease-free survival and LRC were assessed using the Harrell C-index and Cox regression model. Relative thresholds between 40% and 68% and absolute threshold between 5.5 and 7 had a similar predictive value for LRC (C-index = 0.65 and 0.64, respectively). Metabolic tumor volume had a higher predictive value than gross tumor volume (C-index = 0.61) and SUVmax (C-index = 0.54). Metabolic tumor volume computed with a relative threshold of 51% of SUVmax was the best predictor of disease-free survival (hazard ratio, 1.23 [per 10 mL], P = 0.009) and LRC (hazard ratio: 1.22 [per 10 mL], P = 0.02). The use of different thresholds within a reasonable range (between 5.5 and 7 for an absolute threshold and between 40% and 68% for a relative threshold) seems to have no major impact on the predictive value of MTV. This parameter may be used to identify patient with a high risk of recurrence and who may benefit from treatment intensification.

  12. Life cycle assessment of mobility options using wood based fuels--comparison of selected environmental effects and costs.

    PubMed

    Weinberg, Jana; Kaltschmitt, Martin

    2013-12-01

    An environmental assessment and a cost analysis were conducted for mobility options using electricity, hydrogen, ethanol, Fischer-Tropsch diesel and methane derived from wood. Therefore, the overall life cycle with regard to greenhouse gas emissions, acidifying emissions and fossil energy demand as well as costs is analysed. The investigation is carried out for mobility options in 2010 and gives an outlook to the year 2030. Results show that methane utilization in the car is beneficial with regard to environmental impacts (e.g. 58.5 g CO2-eq./km) and costs (23.1 €-ct./km) in 2010, especially in comparison to hydrogen usage (132.4 g CO2-eq./km and 63.9 €-ct./km). The electric vehicle construction has high environmental impacts and costs compared to conventional vehicles today, but with technical improvements and further market penetration, battery electric vehicles can reach the level of concepts with combustion engines in future applications (e.g. cost decrease from 38.7 to 23.4 €-ct./km). Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Monitoring of ovarian activity by measurement of urinary excretion rates using the Ovarian Monitor, Part IV: the relationship of the pregnanediol glucuronide threshold to basal body temperature and cervical mucus as markers for the beginning of the post-ovulatory infertile period.

    PubMed

    Blackwell, Leonard F; Vigil, Pilar; Alliende, María Elena; Brown, Simon; Festin, Mario; Cooke, Delwyn G

    2016-02-01

    Do the basal body temperature (BBT) shift and the cervical mucus markers for the beginning of the post-ovulatory infertile phase (POIP) of a menstrual cycle agree with the corresponding urinary pregnanediol glucuronide (PdG) threshold value? Perfect agreement between the cervical mucus markers and BBT shift and the hormonal definition of the start of post-ovulatory infertility occurred for only 7-17% of the cycles. The PdG threshold of 7.0 µmol/24 h is an objective and accurate marker for the beginning of the POIP. The rise in serum progesterone also produces the BBT shift and changes in cervical mucus which determine the mucus peak. Serum progesterone and urinary PdG are closely correlated when variations in urine volume are taken into account. Individual menstrual cycle profiles of urinary PdG excretion rates for 91 fertile cycles from normally cycling women were analysed to identify the day of the beginning of the POIP. These days were compared with those determined by the day of the BBT shift +2 days, the day of the mucus peak +4 days and the later of these two indicators. The study lasted 3 years. A total of 62 women with normal menstrual cycles were recruited from three centres: Palmerston North, New Zealand; Sydney, Australia and Santiago, Chile. The cycles were displayed individually in a proprietary database program which recorded the PdG excretion rates, the BBT shift day and the cervical mucus peak day. A group of 15 women from a separate Chilean study had PdG urinary data measured as well as their day of ovulation determined by ultrasound. The BBT and cervical mucus markers differed significantly in their identification of the beginning of the POIP when compared with the PdG excretion rate of 7.0 µmol/24 h. The observation that the BBT shift day and the mucus peak day could be identified even though the PdG excretion rates were still at baseline levels in some cycles could lead to an unexpected pregnancy for women using these natural family planning (NFP) indicators. The study consisted only of fertile cycles from women with regular cycles of 20-40 days duration. All the women were intending to avoid a pregnancy during the study, thus the limits of the fertile window were not tested. The NFP signals occurring earlier than the PdG threshold day could lead to an unexpected pregnancy. The signals occurring on the same day or later than the PdG threshold would not lead to unexpected pregnancies, but would require extra abstinence that could lead to non-compliance with the NFP method. A possible improvement in reliability of NFP methods is suggested. This study (project #90905) was funded by the NDP/UNFPA/UNICEF/WHO/World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP). D.G.C. currently works for a diagnostic development company, Science Haven Ltd. The other authors have nothing to declare. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. A novel pre-processing technique for improving image quality in digital breast tomosynthesis.

    PubMed

    Kim, Hyeongseok; Lee, Taewon; Hong, Joonpyo; Sabir, Sohail; Lee, Jung-Ryun; Choi, Young Wook; Kim, Hak Hee; Chae, Eun Young; Cho, Seungryong

    2017-02-01

    Nonlinear pre-reconstruction processing of the projection data in computed tomography (CT) where accurate recovery of the CT numbers is important for diagnosis is usually discouraged, for such a processing would violate the physics of image formation in CT. However, one can devise a pre-processing step to enhance detectability of lesions in digital breast tomosynthesis (DBT) where accurate recovery of the CT numbers is fundamentally impossible due to the incompleteness of the scanned data. Since the detection of lesions such as micro-calcifications and mass in breasts is the purpose of using DBT, it is justified that a technique producing higher detectability of lesions is a virtue. A histogram modification technique was developed in the projection data domain. Histogram of raw projection data was first divided into two parts: One for the breast projection data and the other for background. Background pixel values were set to a single value that represents the boundary between breast and background. After that, both histogram parts were shifted by an appropriate amount of offset and the histogram-modified projection data were log-transformed. Filtered-backprojection (FBP) algorithm was used for image reconstruction of DBT. To evaluate performance of the proposed method, we computed the detectability index for the reconstructed images from clinically acquired data. Typical breast border enhancement artifacts were greatly suppressed and the detectability of calcifications and masses was increased by use of the proposed method. Compared to a global threshold-based post-reconstruction processing technique, the proposed method produced images of higher contrast without invoking additional image artifacts. In this work, we report a novel pre-processing technique that improves detectability of lesions in DBT and has potential advantages over the global threshold-based post-reconstruction processing technique. The proposed method not only increased the lesion detectability but also reduced typical image artifacts pronounced in conventional FBP-based DBT. © 2016 American Association of Physicists in Medicine.

  15. A spatially encoded dose difference maximal intensity projection map for patient dose evaluation: A new first line patient quality assurance tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu Weigang; Graff, Pierre; Boettger, Thomas

    2011-04-15

    Purpose: To develop a spatially encoded dose difference maximal intensity projection (DD-MIP) as an online patient dose evaluation tool for visualizing the dose differences between the planning dose and dose on the treatment day. Methods: Megavoltage cone-beam CT (MVCBCT) images acquired on the treatment day are used for generating the dose difference index. Each index is represented by different colors for underdose, acceptable, and overdose regions. A maximal intensity projection (MIP) algorithm is developed to compress all the information of an arbitrary 3D dose difference index into a 2D DD-MIP image. In such an algorithm, a distance transformation is generatedmore » based on the planning CT. Then, two new volumes representing the overdose and underdose regions of the dose difference index are encoded with the distance transformation map. The distance-encoded indices of each volume are normalized using the skin distance obtained on the planning CT. After that, two MIPs are generated based on the underdose and overdose volumes with green-to-blue and green-to-red lookup tables, respectively. Finally, the two MIPs are merged with an appropriate transparency level and rendered in planning CT images. Results: The spatially encoded DD-MIP was implemented in a dose-guided radiotherapy prototype and tested on 33 MVCBCT images from six patients. The user can easily establish the threshold for the overdose and underdose. A 3% difference between the treatment and planning dose was used as the threshold in the study; hence, the DD-MIP shows red or blue color for the dose difference >3% or {<=}3%, respectively. With such a method, the overdose and underdose regions can be visualized and distinguished without being overshadowed by superficial dose differences. Conclusions: A DD-MIP algorithm was developed that compresses information from 3D into a single or two orthogonal projections while hinting the user whether the dose difference is on the skin surface or deeper.« less

  16. Influence of genetic polymorphisms of FPGS, GGH, and MTHFR on serum methotrexate levels in Chinese children with acute lymphoblastic leukemia.

    PubMed

    Wang, Shu-mei; Sun, Lu-lu; Zeng, Wei-xin; Wu, Wan-shui; Zhang, Guo-liang

    2014-08-01

    To investigate the correlation between common genetic polymorphisms of folylpolyglutamate synthase (FPGS), gamma-glutamyl hydrolase (GGH), and methylenetetrahydrofolate reductase (MTHFR) and serum levels of methotrexate (MTX) in Chinese children with acute lymphoblastic leukemia (ALL). Ninety-one children with ALL who received high-dose MTX were recruited. The polymorphisms FPGS (rs1544105 G>A), GGH (rs3758149 C>T), and MTHFR (rs1801133 C>T) were genotyped through polymerase chain reaction-restriction fragment length polymorphism analysis. Serum MTX was measured by fluorescence polarization immunoassay. The association between targeted polymorphisms and MTX concentration-to-dose (C/D) ratios was assessed, and between targeted polymorphisms and the percent of MTX above the therapeutic threshold (40 µmol/L). The minor allele frequencies of rs1544105 G (34.1%), rs3758149 T (19.2%), and rs1801133 C (48.4%) observed in our population were significantly lower than those reported for European populations (64.2, 30.8, and 69.0%, respectively). The association between the GGH rs3758149 polymorphism and MTX C/D was gender-specific; in girls, the MTX C/D at 24 h of GGH rs3758149 CC carriers (12.09 μmol/L per g/m(2)) was significantly lower than that of CT or TT carriers (16.80 μmol/L per g/m(2)). The percent of serum MTX above the therapeutic threshold in GGH rs3758149 CC carriers (18.3%) was significantly lower than that of CT and TT carriers (38.7%). The MTX C/D ratios at 24 h and the percent of MTX >40 µmol/L for the A-T-T (three variant alleles) haplotype were significantly higher than those for other haplotypes combined (P < 0.05). These data indicate that FPGS rs1544105, GGH rs3758149, and MTHFR rs1801133 polymorphisms contribute to the variability of MTX pharmacokinetics, and their genotyping may be useful to reduce toxicities associated with MTX therapy.

  17. Semiautomatic segmentation of liver metastases on volumetric CT images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Jiayong; Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@cumc.columbia.edu

    2015-11-15

    Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accuratelymore » delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.« less

  18. Effects of Ultrasound Frequency and Tissue Stiffness on the Histotripsy Intrinsic Threshold for Cavitation

    PubMed Central

    Vlaisavljevich, Eli; Lin, Kuang-Wei; Maxwell, Adam; Warnez, Matthew; Mancia, Lauren; Singh, Rahul; Putnam, Andrew J.; Fowlkes, Brian; Johnsen, Eric; Cain, Charles; Xu, Zhen

    2015-01-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated a cavitation cloud can be formed by a single pulse with one high amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1–2 cycles produced by 345 kHz, 500 kHz, 1.5 MHz, and 3 MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results demonstrated that the intrinsic threshold (the negative pressure at which probability=0.5) is independent of stiffness for Young’s moduli (E) < 1 MPa with only a small increase (~2–3 MPa) in the intrinsic threshold for tendon (E=380 MPa). Additionally, results for all samples showed only a small increase of ~2–3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7–30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly impacted by tissue stiffness or ultrasound frequency in hundreds of kHz to MHz range. PMID:25766571

  19. Effects of ultrasound frequency and tissue stiffness on the histotripsy intrinsic threshold for cavitation.

    PubMed

    Vlaisavljevich, Eli; Lin, Kuang-Wei; Maxwell, Adam; Warnez, Matthew T; Mancia, Lauren; Singh, Rahul; Putnam, Andrew J; Fowlkes, Brian; Johnsen, Eric; Cain, Charles; Xu, Zhen

    2015-06-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has indicated that a cavitation cloud can be formed by a single pulse with one high-amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue, and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1-2 cycles produced by 345-kHz, 500-kHz, 1.5-MHz and 3-MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured versus pressure amplitude. The results revealed that the intrinsic threshold (the negative pressure at which probability = 0.5) is independent of stiffness for Young's moduli (E) <1 MPa, with only a small increase (∼2-3 MPa) in the intrinsic threshold for tendon (E = 380 MPa). Additionally, results for all samples revealed only a small increase of ∼2-3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7 and 30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly affected by tissue stiffness or ultrasound frequency in the hundreds of kilohertz to megahertz range. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180.

    PubMed

    Ding, George X; Alaei, Parham; Curran, Bruce; Flynn, Ryan; Gossman, Michael; Mackie, T Rock; Miften, Moyed; Morin, Richard; Xu, X George; Zhu, Timothy C

    2018-05-01

    With radiotherapy having entered the era of image guidance, or image-guided radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning and target localization. The imaging dose delivered may result in excessive dose to sensitive organs and potentially increase the chance of secondary cancers and, therefore, needs to be managed. This task group was charged with: a) providing an overview on imaging dose, including megavoltage electronic portal imaging (MV EPI), kilovoltage digital radiography (kV DR), Tomotherapy MV-CT, megavoltage cone-beam CT (MV-CBCT) and kilovoltage cone-beam CT (kV-CBCT), and b) providing general guidelines for commissioning dose calculation methods and managing imaging dose to patients. We briefly review the dose to radiotherapy (RT) patients resulting from different image guidance procedures and list typical organ doses resulting from MV and kV image acquisition procedures. We provide recommendations for managing the imaging dose, including different methods for its calculation, and techniques for reducing it. The recommended threshold beyond which imaging dose should be considered in the treatment planning process is 5% of the therapeutic target dose. Although the imaging dose resulting from current kV acquisition procedures is generally below this threshold, the ALARA principle should always be applied in practice. Medical physicists should make radiation oncologists aware of the imaging doses delivered to patients under their care. Balancing ALARA with the requirement for effective target localization requires that imaging dose be managed based on the consideration of weighing risks and benefits to the patient. © 2018 American Association of Physicists in Medicine.

  1. Computer-aided detection of lung nodules via 3D fast radial transform, scale space representation, and Zernike MIP classification.

    PubMed

    Riccardi, Alessandro; Petkov, Todor Sergueev; Ferri, Gianluca; Masotti, Matteo; Campanini, Renato

    2011-04-01

    The authors presented a novel system for automated nodule detection in lung CT exams. The approach is based on (1) a lung tissue segmentation preprocessing step, composed of histogram thresholding, seeded region growing, and mathematical morphology; (2) a filtering step, whose aim is the preliminary detection of candidate nodules (via 3D fast radial filtering) and estimation of their geometrical features (via scale space analysis); and (3) a false positive reduction (FPR) step, comprising a heuristic FPR, which applies thresholds based on geometrical features, and a supervised FPR, which is based on support vector machines classification, which in turn, is enhanced by a feature extraction algorithm based on maximum intensity projection processing and Zernike moments. The system was validated on 154 chest axial CT exams provided by the lung image database consortium public database. The authors obtained correct detection of 71% of nodules marked by all radiologists, with a false positive rate of 6.5 false positives per patient (FP/patient). A higher specificity of 2.5 FP/patient was reached with a sensitivity of 60%. An independent test on the ANODE09 competition database obtained an overall score of 0.310. The system shows a novel approach to the problem of lung nodule detection in CT scans: It relies on filtering techniques, image transforms, and descriptors rather than region growing and nodule segmentation, and the results are comparable to those of other recent systems in literature and show little dependency on the different types of nodules, which is a good sign of robustness.

  2. Management Strategies for Dual-Career Couples.

    ERIC Educational Resources Information Center

    Kater, Donna

    1985-01-01

    Suggestions are presented that focus on strategies to alleviate those stresses arising from internal sources. These strategies include enhancing communication skills, relieving role overload, and minimizing multiple role-cycling. (CT)

  3. A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images.

    PubMed

    Dall'Ara, E; Varga, P; Pahr, D; Zysset, P

    2011-05-01

    The accuracy of QCT-based homogenized finite element (FE) models is strongly related to the accuracy of the prediction of bone volume fraction (BV/TV) from bone mineral density (BMD). The goal of this study was to establish a calibration methodology to relate the BMD computed with QCT with the BV/TV computed with micro-CT (microCT) over a wide range of bone mineral densities and to investigate the effect of region size in which BMD and BV/TV are computed. Six human vertebral bodies were dissected from the spine of six donors and scanned submerged in water with QCT (voxel size: 0.391 x 0.391 x 0.450 mm3) and microCT (isotropic voxel size: 0.018(3) mm3). The microCT images were segmented with a single level threshold. Afterward, QCT-grayscale, microCT-grayscale, and microCT-segmented images were registered. Two isotropic grids of 1.230 mm (small) and 4.920 mm (large) were superimposed on every image, and QCT(BMD) was compared both with microCT(BMD) and microCT(BV/TV) for each grid cell. The ranges of QCT(BMD) for large and small regions were 9-559 mg/cm3 and -90 to 1006 mg/cm3, respectively. QCT(BMD) was found to overestimate microCT(BMD). No significant differences were found between the QCT(BMD)-microCT(BV/TV) regression parameters of the two grid sizes. However, the R2 was higher, and the standard error of the estimate (SEE) was lower for large regions when compared to small regions. For the pooled data, an extrapolated QCTBMD value equal to 1062 mg/ cm3 was found to correspond to 100% microCT(BV/TV). A calibration method was defined to evaluate BV/TV from QCTBMD values for cortical and trabecular bone in vitro. The QCT(BMD-microCT(BV/TV) calibration was found to be dependent on the scanned vertebral section but not on the size of the regions. However, the higher SEE computed for small regions suggests that the deleterious effect of QCT image noise on FE modelling increases with decreasing voxel size.

  4. MPN estimation of qPCR target sequence recoveries from whole cell calibrator samples.

    PubMed

    Sivaganesan, Mano; Siefring, Shawn; Varma, Manju; Haugland, Richard A

    2011-12-01

    DNA extracts from enumerated target organism cells (calibrator samples) have been used for estimating Enterococcus cell equivalent densities in surface waters by a comparative cycle threshold (Ct) qPCR analysis method. To compare surface water Enterococcus density estimates from different studies by this approach, either a consistent source of calibrator cells must be used or the estimates must account for any differences in target sequence recoveries from different sources of calibrator cells. In this report we describe two methods for estimating target sequence recoveries from whole cell calibrator samples based on qPCR analyses of their serially diluted DNA extracts and most probable number (MPN) calculation. The first method employed a traditional MPN calculation approach. The second method employed a Bayesian hierarchical statistical modeling approach and a Monte Carlo Markov Chain (MCMC) simulation method to account for the uncertainty in these estimates associated with different individual samples of the cell preparations, different dilutions of the DNA extracts and different qPCR analytical runs. The two methods were applied to estimate mean target sequence recoveries per cell from two different lots of a commercially available source of enumerated Enterococcus cell preparations. The mean target sequence recovery estimates (and standard errors) per cell from Lot A and B cell preparations by the Bayesian method were 22.73 (3.4) and 11.76 (2.4), respectively, when the data were adjusted for potential false positive results. Means were similar for the traditional MPN approach which cannot comparably assess uncertainty in the estimates. Cell numbers and estimates of recoverable target sequences in calibrator samples prepared from the two cell sources were also used to estimate cell equivalent and target sequence quantities recovered from surface water samples in a comparative Ct method. Our results illustrate the utility of the Bayesian method in accounting for uncertainty, the high degree of precision attainable by the MPN approach and the need to account for the differences in target sequence recoveries from different calibrator sample cell sources when they are used in the comparative Ct method. Published by Elsevier B.V.

  5. Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections.

    PubMed

    Jones, Ryan M; O'Reilly, Meaghan A; Hynynen, Kullervo

    2015-07-01

    Experimentally verify a previously described technique for performing passive acoustic imaging through an intact human skull using noninvasive, computed tomography (CT)-based aberration corrections Jones et al. [Phys. Med. Biol. 58, 4981-5005 (2013)]. A sparse hemispherical receiver array (30 cm diameter) consisting of 128 piezoceramic discs (2.5 mm diameter, 612 kHz center frequency) was used to passively listen through ex vivo human skullcaps (n = 4) to acoustic emissions from a narrow-band fixed source (1 mm diameter, 516 kHz center frequency) and from ultrasound-stimulated (5 cycle bursts, 1 Hz pulse repetition frequency, estimated in situ peak negative pressure 0.11-0.33 MPa, 306 kHz driving frequency) Definity™ microbubbles flowing through a thin-walled tube phantom. Initial in vivo feasibility testing of the method was performed. The performance of the method was assessed through comparisons to images generated without skull corrections, with invasive source-based corrections, and with water-path control images. For source locations at least 25 mm from the inner skull surface, the modified reconstruction algorithm successfully restored a single focus within the skull cavity at a location within 1.25 mm from the true position of the narrow-band source. The results obtained from imaging single bubbles are in good agreement with numerical simulations of point source emitters and the authors' previous experimental measurements using source-based skull corrections O'Reilly et al. [IEEE Trans. Biomed. Eng. 61, 1285-1294 (2014)]. In a rat model, microbubble activity was mapped through an intact human skull at pressure levels below and above the threshold for focused ultrasound-induced blood-brain barrier opening. During bursts that led to coherent bubble activity, the location of maximum intensity in images generated with CT-based skull corrections was found to deviate by less than 1 mm, on average, from the position obtained using source-based corrections. Taken together, these results demonstrate the feasibility of using the method to guide bubble-mediated ultrasound therapies in the brain. The technique may also have application in ultrasound-based cerebral angiography.

  6. Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections

    PubMed Central

    Jones, Ryan M.; O’Reilly, Meaghan A.; Hynynen, Kullervo

    2015-01-01

    Purpose: Experimentally verify a previously described technique for performing passive acoustic imaging through an intact human skull using noninvasive, computed tomography (CT)-based aberration corrections Jones et al. [Phys. Med. Biol. 58, 4981–5005 (2013)]. Methods: A sparse hemispherical receiver array (30 cm diameter) consisting of 128 piezoceramic discs (2.5 mm diameter, 612 kHz center frequency) was used to passively listen through ex vivo human skullcaps (n = 4) to acoustic emissions from a narrow-band fixed source (1 mm diameter, 516 kHz center frequency) and from ultrasound-stimulated (5 cycle bursts, 1 Hz pulse repetition frequency, estimated in situ peak negative pressure 0.11–0.33 MPa, 306 kHz driving frequency) Definity™ microbubbles flowing through a thin-walled tube phantom. Initial in vivo feasibility testing of the method was performed. The performance of the method was assessed through comparisons to images generated without skull corrections, with invasive source-based corrections, and with water-path control images. Results: For source locations at least 25 mm from the inner skull surface, the modified reconstruction algorithm successfully restored a single focus within the skull cavity at a location within 1.25 mm from the true position of the narrow-band source. The results obtained from imaging single bubbles are in good agreement with numerical simulations of point source emitters and the authors’ previous experimental measurements using source-based skull corrections O’Reilly et al. [IEEE Trans. Biomed. Eng. 61, 1285–1294 (2014)]. In a rat model, microbubble activity was mapped through an intact human skull at pressure levels below and above the threshold for focused ultrasound-induced blood–brain barrier opening. During bursts that led to coherent bubble activity, the location of maximum intensity in images generated with CT-based skull corrections was found to deviate by less than 1 mm, on average, from the position obtained using source-based corrections. Conclusions: Taken together, these results demonstrate the feasibility of using the method to guide bubble-mediated ultrasound therapies in the brain. The technique may also have application in ultrasound-based cerebral angiography. PMID:26133635

  7. Can adaptive threshold-based metabolic tumor volume (MTV) and lean body mass corrected standard uptake value (SUL) predict prognosis in head and neck cancer patients treated with definitive radiotherapy/chemoradiotherapy?

    PubMed

    Akagunduz, Ozlem Ozkaya; Savas, Recep; Yalman, Deniz; Kocacelebi, Kenan; Esassolak, Mustafa

    2015-11-01

    To evaluate the predictive value of adaptive threshold-based metabolic tumor volume (MTV), maximum standardized uptake value (SUVmax) and maximum lean body mass corrected SUV (SULmax) measured on pretreatment positron emission tomography and computed tomography (PET/CT) imaging in head and neck cancer patients treated with definitive radiotherapy/chemoradiotherapy. Pretreatment PET/CT of the 62 patients with locally advanced head and neck cancer who were treated consecutively between May 2010 and February 2013 were reviewed retrospectively. The maximum FDG uptake of the primary tumor was defined according to SUVmax and SULmax. Multiple threshold levels between 60% and 10% of the SUVmax and SULmax were tested with intervals of 5% to 10% in order to define the most suitable threshold value for the metabolic activity of each patient's tumor (adaptive threshold). MTV was calculated according to this value. We evaluated the relationship of mean values of MTV, SUVmax and SULmax with treatment response, local recurrence, distant metastasis and disease-related death. Receiver-operating characteristic (ROC) curve analysis was done to obtain optimal predictive cut-off values for MTV and SULmax which were found to have a predictive value. Local recurrence-free (LRFS), disease-free (DFS) and overall survival (OS) were examined according to these cut-offs. Forty six patients had complete response, 15 had partial response, and 1 had stable disease 6 weeks after the completion of treatment. Median follow-up of the entire cohort was 18 months. Of 46 complete responders 10 had local recurrence, and of 16 partial or no responders 10 had local progression. Eighteen patients died. Adaptive threshold-based MTV had significant predictive value for treatment response (p=0.011), local recurrence/progression (p=0.050), and disease-related death (p=0.024). SULmax had a predictive value for local recurrence/progression (p=0.030). ROC curves analysis revealed a cut-off value of 14.00 mL for MTV and 10.15 for SULmax. Three-year LRFS and DFS rates were significantly lower in patients with MTV ≥ 14.00 mL (p=0.026, p=0.018 respectively), and SULmax≥10.15 (p=0.017, p=0.022 respectively). SULmax did not have a significant predictive value for OS whereas MTV had (p=0.025). Adaptive threshold-based MTV and SULmax could have a role in predicting local control and survival in head and neck cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. The cost-effectiveness of CT-guided sacroiliac joint injections: a measure of QALY gained.

    PubMed

    Bydon, Mohamad; Macki, Mohamed; De la Garza-Ramos, Rafael; Youssef, Mina; Gokaslan, Ziya L; Meleka, Sherif; Bydon, Ali

    2014-10-01

    The purpose of this study is to estimate the total cost and the quality of life years (QALY) gained for computer tomography (CT)-guided sacroiliac joint (SIJ) injections. The cost per QALY gained for the procedure is the primary end-point of this study. In our 1-year prospective institutional study, we gathered 30 patients undergoing CT-guided SIJ injections for degenerative changes at the SIJ space. Patient-reported outcomes included both the US population-based EQ-5D (EuroQol) index score and the EQ-visual analog scale (VAS). The EQ-5D is based on mobility, self-care, usual activities, pain/discomfort, and anxiety depression. Utility expenditures were based on hospital charges at our institution. All 30 patients had one pre-injection physician visit followed by 43 initial injections (13 bilateral). Each patient underwent one CT scan, and three patients required additional plain films. In the 1 year following the injections, 26 physician visits were documented. Five patients required repeat CT-guided injections. Total 1-year cost for all 30 patients was $34 874·00. Mean decrease in EQ-VAS was 0·60 (P  =  0·187). The mean 1-year gain of 0·58 EQ-5D QALY reached statistical significance (P < 0·001). The cost per QALY gained by CT-guided sacroiliac injections was $2004·29. In one of the first cost analyses of CT-guided sacroiliac injections, we found that the procedure improves pain and activities of daily living. The cost per QALY gained by CT-guided sacroiliac injections falls well below the threshold cost of 1 QALY, suggesting that the procedure is strongly cost-effective.

  9. Intra-tumour 18F-FDG uptake heterogeneity decreases the reliability on target volume definition with positron emission tomography/computed tomography imaging.

    PubMed

    Dong, Xinzhe; Wu, Peipei; Sun, Xiaorong; Li, Wenwu; Wan, Honglin; Yu, Jinming; Xing, Ligang

    2015-06-01

    This study aims to explore whether the intra-tumour (18) F-fluorodeoxyglucose (FDG) uptake heterogeneity affects the reliability of target volume definition with FDG positron emission tomography/computed tomography (PET/CT) imaging for nonsmall cell lung cancer (NSCLC) and squamous cell oesophageal cancer (SCEC). Patients with NSCLC (n = 50) or SCEC (n = 50) who received (18)F-FDG PET/CT scanning before treatments were included in this retrospective study. Intra-tumour FDG uptake heterogeneity was assessed by visual scoring, the coefficient of variation (COV) of the standardised uptake value (SUV) and the image texture feature (entropy). Tumour volumes (gross tumour volume (GTV)) were delineated on the CT images (GTV(CT)), the fused PET/CT images (GTV(PET-CT)) and the PET images, using a threshold at 40% SUV(max) (GTV(PET40%)) or the SUV cut-off value of 2.5 (GTV(PET2.5)). The correlation between the FDG uptake heterogeneity parameters and the differences in tumour volumes among GTV(CT), GTV(PET-CT), GTV(PET40%) and GTV(PET2.5) was analysed. For both NSCLC and SCEC, obvious correlations were found between uptake heterogeneity, SUV or tumour volumes. Three types of heterogeneity parameters were consistent and closely related to each other. Substantial differences between the four methods of GTV definition were found. The differences between the GTV correlated significantly with PET heterogeneity defined with the visual score, the COV or the textural feature-entropy for NSCLC and SCEC. In tumours with a high FDG uptake heterogeneity, a larger GTV delineation difference was found. Advance image segmentation algorithms dealing with tracer uptake heterogeneity should be incorporated into the treatment planning system. © 2015 The Royal Australian and New Zealand College of Radiologists.

  10. Cyst-based measurements for assessing lymphangioleiomyomatosis in computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo, P., E-mail: pechinlo@mednet.edu.ucla; Brown, M. S.; Kim, H.

    Purpose: To investigate the efficacy of a new family of measurements made on individual pulmonary cysts extracted from computed tomography (CT) for assessing the severity of lymphangioleiomyomatosis (LAM). Methods: CT images were analyzed using thresholding to identify a cystic region of interest from chest CT of LAM patients. Individual cysts were then extracted from the cystic region by the watershed algorithm, which separates individual cysts based on subtle edges within the cystic regions. A family of measurements were then computed, which quantify the amount, distribution, and boundary appearance of the cysts. Sequential floating feature selection was used to select amore » small subset of features for quantification of the severity of LAM. Adjusted R{sup 2} from multiple linear regression and R{sup 2} from linear regression against measurements from spirometry were used to compare the performance of our proposed measurements with currently used density based CT measurements in the literature, namely, the relative area measure and the D measure. Results: Volumetric CT data, performed at total lung capacity and residual volume, from a total of 49 subjects enrolled in the MILES trial were used in our study. Our proposed measures had adjusted R{sup 2} ranging from 0.42 to 0.59 when regressing against the spirometry measures, with p < 0.05. For previously used density based CT measurements in the literature, the best R{sup 2} was 0.46 (for only one instance), with the majority being lower than 0.3 or p > 0.05. Conclusions: The proposed family of CT-based cyst measurements have better correlation with spirometric measures than previously used density based CT measurements. They show potential as a sensitive tool for quantitatively assessing the severity of LAM.« less

  11. Impact of Emergent Circulating Tumor DNA RAS Mutation in Panitumumab-Treated Chemoresistant Metastatic Colorectal Cancer.

    PubMed

    Kim, Tae Won; Peeters, Marc; Thomas, Anne L; Gibbs, Peter; Hool, Kristina; Zhang, Jianqi; Ang, Agnes; Bach, Bruce Allen; Price, Timothy

    2018-06-13

    The accumulation of emergent RAS mutations during anti-epidermal growth factor receptor (EGFR) therapy is of interest as a mechanism for acquired resistance to anti-EGFR treatment. Plasma analysis of circulating tumor (ct) DNA is a minimally invasive and highly sensitive method to determine RAS mutational status. This biomarker analysis of the global phase III ASPECCT study used next-generation sequencing to detect expanded RAS ctDNA mutations in panitumumab-treated patients. Plasma samples collected at baseline and posttreatment were analyzed categorically for the presence of RAS mutations by the Plasma Select -R™ 64-gene panel at 0.1% sensitivity. Among panitumumab-treated patients with evaluable plasma samples at baseline (n = 238), 188 (79%) were wild-type (WT) RAS, and 50 (21%) were mutant RAS Of the 188 patients with baseline ctDNA WT RAS status, 164 had evaluable posttreatment results with a 32% rate of emergent RAS mutations. The median overall survival (OS) for WT and RAS mutant status by ctDNA at baseline was 13.7 (95% confidence interval: 11.5-15.4) and 7.9 months (6.4-9.6), respectively ( P < 0.0001). Clinical outcomes were not significantly different between patients with and without emergent ctDNA RAS mutations. Although patients with baseline ctDNA RAS mutations had worse outcomes than patients who were WT RAS before initiating treatment, emergent ctDNA RAS mutations were not associated with less favorable patient outcomes in panitumumab-treated patients. Further research is needed to determine a clinically relevant threshold for baseline and emergent ctDNA RAS mutations. Copyright ©2018, American Association for Cancer Research.

  12. Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tselikas, Lambros, E-mail: lambros.tselikas@gmail.com; Joskin, Julien, E-mail: j.joskin@gmail.com; Roquet, Florian, E-mail: florianroquet@hotmail.com

    2015-02-15

    PurposeThis study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance).MethodsSixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared.ResultsAll biopsiesmore » were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01).ConclusionsFP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.« less

  13. Masking potency and whiteness of noise at various noise check sizes.

    PubMed

    Kukkonen, H; Rovamo, J; Näsänen, R

    1995-02-01

    The masking effect of spatial noise can be increased by increasing either the rms contrast or check size of noise. In this study, the authors investigated the largest noise check size that still mimics the effect of white noise in grating detection and how it depends on the bandwidth and spatial frequency of a grating. The authors measured contrast energy thresholds, E, for vertical cosine gratings at various spatial frequencies and bandwidths. Gratings were embedded in two-dimensional spatial noise. The side length of the square noise checks was varied in the experiments. The spectral density, N(0,0), of white spatial noise at zero frequency was calculated by multiplying the noise check area by the rms contrast of noise squared. The physical signal-to-noise ratio at threshold [E/N(0,0)]0.5 was initially constant but then started to decrease. The largest noise check that still produced a constant physical signal-to-noise ratio at threshold was directly proportional to the spatial frequency. When expressed as a fraction of grating cycle, the largest noise check size depended only on stimulus bandwidth. The smallest number of noise checks per grating cycle needed to mimic the effect of white noise decreased from 4.2 to 2.6 when the number of grating cycles increased from 1 to 64. Spatial noise can be regarded as white in grating detection if there are at least four square noise checks per grating cycle at all spatial frequencies.

  14. Moderate Intensity Cycling Exercise after Upper Extremity Resistance Training Interferes Response to Muscle Hypertrophy but Not Strength Gains

    PubMed Central

    Tomiya, Shigeto; Kikuchi, Naoki; Nakazato, Koichi

    2017-01-01

    The purpose of the present study was to examine the effect of 30-min moderate intensity cycling exercise immediately after upper-body resistance training on the muscle hypertrophy and strength gain. Fourteen subjects were randomly divided between two groups. One group performed moderate intensity (55% of maximum oxygen consumption [VO2max], 30 min) cycle training immediately after arm resistance training as concurrent training (CT; n = 7, age: 21.8 ± 0.7 years, height: 1.68 ± 0.06 m, weight: 60.3 ± 7.4 kg); the second group performed the same endurance and arm RT on separate days as control group (SEP; n=7, age: 22.1 ± 0.7 years, height: 1.76 ± 0.05 m, weight: 63.8 ± 3.6 kg). The supervised progressive RT program was designed to induce muscular hypertrophy (3-5 sets of 10 repetitions) with bilateral arm-curl exercise using 75% of the one repetition maximum (1RM) with 2-min rest intervals. The RT program was performed for 8 weeks, twice per week. Muscle cross-sectional area (CSA), 1RM, and VO2max were measured pre- and post-training. Significant increases in muscle CSA from pre- to post-training were observed in both the SEP (p = 0.001, effect size [ES] = 0.84) and the CT groups (p = 0.004, ES = 0.45). A significant increase in 1RM from pre- to post-training was observed in the SEP (p = 0.025, ES = 0.91) and CT groups (p = 0.001, ES = 2.38). There were no interaction effects (time × group) for CSA, 1RM, or VO2max. A significantly higher percentage change of CSA was observed in the SEP group (12.1 ± 4.9%) compared to the CT group (5.0 ± 2.7%, p = 0.029), but no significant difference was observed in the 1RM (SEP: 19.8 ± 16.8%, CT: 24.3 ± 11.1%). The data suggest that significant improvement of CSA and strength can be expected with progressive resistance training with subsequent endurance exercise performed immediately or on a different day. Changes in CSA might be affected by subsequent cycling exercise after 8 weeks of training. Key points Moderate intensity cycling exercise immediately after upper-body resistance training influences the magnitude of muscle hypertrophy and relative value of CSA changes. There was no statistically significant difference in the % change in 1RM between groups after concurrent strength training and moderate intensity endurance training. Timing of endurance training could alter the degree of muscular growth induced by resistance training. PMID:28912657

  15. Centrifugal unbalance detection system

    DOEpatents

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  16. Prevalence of Imaging Biomarkers to Guide the Planning of Acute Stroke Reperfusion Trials.

    PubMed

    Jiang, Bin; Ball, Robyn L; Michel, Patrik; Jovin, Tudor; Desai, Manisha; Eskandari, Ashraf; Naqvi, Zack; Wintermark, Max

    2017-06-01

    Imaging biomarkers are increasingly used as selection criteria for stroke clinical trials. The goal of our study was to determine the prevalence of commonly studied imaging biomarkers in different time windows after acute ischemic stroke onset to better facilitate the design of stroke clinical trials using such biomarkers for patient selection. This retrospective study included 612 patients admitted with a clinical suspicion of acute ischemic stroke with symptom onset no more than 24 hours before completing baseline imaging. Patients with subacute/chronic/remote infarcts and hemorrhage were excluded from this study. Imaging biomarkers were extracted from baseline imaging, which included a noncontrast head computed tomography (CT), perfusion CT, and CT angiography. The prevalence of dichotomized versions of each of the imaging biomarkers in several time windows (time since symptom onset) was assessed and statistically modeled to assess time dependence (not lack thereof). We created tables showing the prevalence of the imaging biomarkers pertaining to the core, the penumbra and the arterial occlusion for different time windows. All continuous imaging features vary over time. The dichotomized imaging features that vary significantly over time include: noncontrast head computed tomography Alberta Stroke Program Early CT (ASPECT) score and dense artery sign, perfusion CT infarct volume, and CT angiography collateral score and visible clot. The dichotomized imaging features that did not vary significantly over time include the thresholded perfusion CT penumbra volumes. As part of the feasibility analysis in stroke clinical trials, this analysis and the resulting tables can help investigators determine sample size and the number needed to screen. © 2017 American Heart Association, Inc.

  17. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

    PubMed

    Goo, Hyun Woo; Park, Sang Hyub

    2017-11-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy.

  18. Microstructure analysis of the secondary pulmonary lobules by 3D synchrotron radiation CT

    NASA Astrophysics Data System (ADS)

    Fukuoka, Y.; Kawata, Y.; Niki, N.; Umetani, K.; Nakano, Y.; Ohmatsu, H.; Moriyama, N.; Itoh, H.

    2014-03-01

    Recognition of abnormalities related to the lobular anatomy has become increasingly important in the diagnosis and differential diagnosis of lung abnormalities at clinical routines of CT examinations. This paper aims a 3-D microstructural analysis of the pulmonary acinus with isotropic spatial resolution in the range of several micrometers by using micro CT. Previously, we demonstrated the ability of synchrotron radiation micro CT (SRμCT) using offset scan mode in microstructural analysis of the whole part of the secondary pulmonary lobule. In this paper, we present a semiautomatic method to segment the acinar and subacinar airspaces from the secondary pulmonary lobule and to track small vessels running inside alveolar walls in human acinus imaged by the SRμCT. The method beains with and segmentation of the tissues such as pleural surface, interlobular septa, alveola wall, or vessel using a threshold technique and 3-D connected component analysis. 3-D air space are then conustructed separated by tissues and represented branching patterns of airways and airspaces distal to the terminal bronchiole. A graph-partitioning approach isolated acini whose stems are interactively defined as the terminal bronchiole in the secondary pulmonary lobule. Finally, we performed vessel tracking using a non-linear sate space which captures both smoothness of the trajectories and intensity coherence along vessel orientations. Results demonstrate that the proposed method can extract several acinar airspaces from the 3-D SRμCT image of secondary pulmonary lobule and that the extracted acinar airspace enable an accurate quantitative description of the anatomy of the human acinus for interpretation of the basic unit of pulmonary structure and function.

  19. Automatic tube current modulation technique for multidetector CT: is it effective with a 64-detector CT?

    PubMed

    Funama, Yoshinori; Awai, Kazuo; Hatemura, Masahiro; Shimamura, Masamitchi; Yanaga, Yumi; Oda, Seitaro; Yamashita, Yasuyuki

    2008-01-01

    To investigate whether it is possible to obtain adequate images at uniform image noise levels and reduced radiation exposure with our automatic tube current modulation (ATCM) technique for 64-detector CT. The study population consisted of 64 patients with known or suspected lung or abdominal disease. We used a 64-detector CT scanner (LightSpeed VCT, GE Healthcare, Waukesha, WI, USA) and a combined angular and longitudinal tube current modulation technique (Smart mA, GE Healthcare, Waukesha, WI, USA) to examine 34 patients. The scanning parameters were identical; the minimum and maximum tube current thresholds were 50 and 800 mA, respectively. For study of the constant tube current technique, 30 additional patients were examined at 350 mA. The CT number and image noise (SD of the CT number) were measured in the 64 patients at six levels, i.e., the center of the left ventricle, the liver dome, the porta hepatis, the center of the spleen and the right and left renal pelvis. When we used the ATCM technique, the mean image noise ranged from 8.40 at the center of the left ventricle to 11.31 at the porta hepatis; the mean tube current ranged from 105.9 mAs at the center of the left ventricle to 169.6 mAs at the center of the spleen. The mean dose reduction rate per constant tube current at 175 mAs ranged from 3.1 to 39.5%. By use of the ATCM technique, it is possible to maintain a constant image noise level with a 64-detector CT.

  20. SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, H; Fatemi, A; Sahgal, A

    Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy.more » The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.« less

  1. Caries-removal effectiveness of a papain-based chemo-mechanical agent: A quantitative micro-CT study.

    PubMed

    Neves, Aline A; Lourenço, Roseane A; Alves, Haimon D; Lopes, Ricardo T; Primo, Laura G

    2015-01-01

    The aim of this study was to access the effectiveness and specificity of a papain-based chemo-mechanical caries-removal agent in providing minimum residual caries after cavity preparation. In order to do it, extracted carious molars were selected and scanned in a micro-CT before and after caries-removal procedures with the papain-based gel. Similar parameters for acquisition and reconstruction of the image stacks were used between the scans. After classification of the dentin substrate based on mineral density intervals and establishment of a carious tissue threshold, volumetric parameters related to effectiveness (mineral density of removed dentin volume and residual dentin tissue) and specificity (relation between carious dentin in removed volume and initial caries) of this caries-removal agent were obtained. In general, removed dentin volume was similar or higher than the initial carious volume, indicating that the method was able to effectively remove dentin tissue. Samples with an almost perfect accuracy in carious dentin removal also showed an increased removal of caries-affected tissue. On the contrary, less or no affected dentin was removed in samples where some carious tissue was left in residual dentin. Mineral density values in residual dentin were always higher or similar to the threshold for mineral density values in carious dentin. In conclusion, the papain-based gel was effective in removing carious dentin up to a conservative in vitro threshold. Lesion characteristics, such as activity and morphology of enamel lesion, may also influence caries-removal properties of the method. © Wiley Periodicals, Inc.

  2. Texture-based segmentation and analysis of emphysema depicted on CT images

    NASA Astrophysics Data System (ADS)

    Tan, Jun; Zheng, Bin; Wang, Xingwei; Lederman, Dror; Pu, Jiantao; Sciurba, Frank C.; Gur, David; Leader, J. Ken

    2011-03-01

    In this study we present a texture-based method of emphysema segmentation depicted on CT examination consisting of two steps. Step 1, a fractal dimension based texture feature extraction is used to initially detect base regions of emphysema. A threshold is applied to the texture result image to obtain initial base regions. Step 2, the base regions are evaluated pixel-by-pixel using a method that considers the variance change incurred by adding a pixel to the base in an effort to refine the boundary of the base regions. Visual inspection revealed a reasonable segmentation of the emphysema regions. There was a strong correlation between lung function (FEV1%, FEV1/FVC, and DLCO%) and fraction of emphysema computed using the texture based method, which were -0.433, -.629, and -0.527, respectively. The texture-based method produced more homogeneous emphysematous regions compared to simple thresholding, especially for large bulla, which can appear as speckled regions in the threshold approach. In the texture-based method, single isolated pixels may be considered as emphysema only if neighboring pixels meet certain criteria, which support the idea that single isolated pixels may not be sufficient evidence that emphysema is present. One of the strength of our complex texture-based approach to emphysema segmentation is that it goes beyond existing approaches that typically extract a single or groups texture features and individually analyze the features. We focus on first identifying potential regions of emphysema and then refining the boundary of the detected regions based on texture patterns.

  3. A volumetric pulmonary CT segmentation method with applications in emphysema assessment

    NASA Astrophysics Data System (ADS)

    Silva, José Silvestre; Silva, Augusto; Santos, Beatriz S.

    2006-03-01

    A segmentation method is a mandatory pre-processing step in many automated or semi-automated analysis tasks such as region identification and densitometric analysis, or even for 3D visualization purposes. In this work we present a fully automated volumetric pulmonary segmentation algorithm based on intensity discrimination and morphologic procedures. Our method first identifies the trachea as well as primary bronchi and then the pulmonary region is identified by applying a threshold and morphologic operations. When both lungs are in contact, additional procedures are performed to obtain two separated lung volumes. To evaluate the performance of the method, we compared contours extracted from 3D lung surfaces with reference contours, using several figures of merit. Results show that the worst case generally occurs at the middle sections of high resolution CT exams, due the presence of aerial and vascular structures. Nevertheless, the average error is inferior to the average error associated with radiologist inter-observer variability, which suggests that our method produces lung contours similar to those drawn by radiologists. The information created by our segmentation algorithm is used by an identification and representation method in pulmonary emphysema that also classifies emphysema according to its severity degree. Two clinically proved thresholds are applied which identify regions with severe emphysema, and with highly severe emphysema. Based on this thresholding strategy, an application for volumetric emphysema assessment was developed offering new display paradigms concerning the visualization of classification results. This framework is easily extendable to accommodate other classifiers namely those related with texture based segmentation as it is often the case with interstitial diseases.

  4. Reduction in growth threshold for pulmonary metastases: an opportunity for volumetry and its impact on treatment decisions.

    PubMed

    Vogel, M N; Schmücker, S; Maksimovic, O; Hartmann, J; Claussen, C D; Horger, M

    2012-07-01

    This study compares tumour response assessment by automated CT volumetry and standard manual measurements regarding the impact on treatment decisions and patient outcome. 58 consecutive patients with 203 pulmonary metastases undergoing baseline and follow-up multirow detector CT (MDCT) under chemotherapy were assessed for response to chemotherapy. Tumour burden of pulmonary target lesions was quantified in three ways: (1) following response evaluation criteria in solid tumours (RECIST); (2) following the volume equivalents of RECIST (i.e. with a threshold of -65/+73%); and (3) using calculated limits for stable disease (SD). For volumetry, calculated limits had been set at ±38% prior to the study by repeated quantification of nodules scanned twice. Results were compared using non-weighted κ-values and were evaluated for their impact on treatment decisions and patient outcome. In 15 (17%) of the 58 patients, the results of response assessment were inconsistent with 1 of the 3 methods, which would have had an impact on treatment decisions in 8 (13%). Patient outcome regarding therapy response could be verified in 5 (33%) of the 15 patients with inconsistent measurement results and was consistent with both RECIST and volumetry in 1, with calculated limits in 3 and with none in 1. Diagnosis as to the overall response was consistent with RECIST in six patients, with volumetry in six and with calculated limits in eight cases. There is an impact of different methods for therapy response assessment on treatment decisions. A reduction of threshold for SD to ±30-40% of volume change seems reasonable when using volumetry.

  5. Presence of a temperature gradient among genital tract portions and the thermal changes within these portions over the estrous cycle in beef cows.

    PubMed

    El-Sheikh Ali, Hossam; Kitahara, Go; Tamura, Youji; Kobayashi, Ikuo; Hemmi, Koichiro; Torisu, Shidow; Sameshima, Hiroshi; Horii, Yoichiro; Zaabel, Samy; Kamimura, Shunichi

    2013-01-01

    The aim of the present study was to describe the temperature of the different portions of the female genital tract and their relation to rectal temperature and to investigate the effect of steroid hormones profiles on these variables over the estrous cycle in cattle. Four nonpregnant Japanese Black cows were investigated daily over two successive estrous cycles using a digital thermometer with a long probe and rounded-end sensor to record the temperature of the rectum (RT), vagina (VT), cervix (CT), uterine body (UBT) and uterine horns (UHT). Blood samples were collected immediately before temperature recording to assay peripheral levels of progesterone (P(4)) and estradiol-17β (E(2)). Moreover, transrectal ultrasonography was carried out after temperature recording to monitor the ovulatory follicle and track ovulation. During the experiment, the ambient temperature and relative humidity were recorded for further calculation of the temperature humidity index (THI). The temperature within the genital tracts in these cows progressively increased towards the uterine horns from the vagina. The VT, CT, UBT and UHTs were significantly higher in association with peripheral P(4) concentrations greater than 4 ng/ml (mid-luteal phase) when compared with lower peripheral P(4) concentrations. The VT was more significantly (P<0.01) correlated to the CT, UBT and UHTs than RT. In conclusion, a temperature gradient was present among the vagina, cervix and uterus over the estrous cycle, and changes in peripheral P(4) concentrations were associated with the thermal variations within these portions. The VT could be more beneficial than RT in monitoring temperature of deeper portions of the female genital tract in bovine.

  6. Presence of a Temperature Gradient Among Genital Tract Portions and the Thermal Changes Within These Portions Over the Estrous Cycle in Beef Cows

    PubMed Central

    EL-SHEIKH ALI, Hossam; KITAHARA, Go; TAMURA, Youji; KOBAYASHI, Ikuo; HEMMI, Koichiro; TORISU, Shidow; SAMESHIMA, Hiroshi; HORII, Yoichiro; ZAABEL, Samy; KAMIMURA, Shunichi

    2012-01-01

    Abstract The aim of the present study was to describe the temperature of the different portions of the female genital tract and their relation to rectal temperature and to investigate the effect of steroid hormones profiles on these variables over the estrous cycle in cattle. Four nonpregnant Japanese Black cows were investigated daily over two successive estrous cycles using a digital thermometer with a long probe and rounded-end sensor to record the temperature of the rectum (RT), vagina (VT), cervix (CT), uterine body (UBT) and uterine horns (UHT). Blood samples were collected immediately before temperature recording to assay peripheral levels of progesterone (P4) and estradiol-17β (E2). Moreover, transrectal ultrasonography was carried out after temperature recording to monitor the ovulatory follicle and track ovulation. During the experiment, the ambient temperature and relative humidity were recorded for further calculation of the temperature humidity index (THI). The temperature within the genital tracts in these cows progressively increased towards the uterine horns from the vagina. The VT, CT, UBT and UHTs were significantly higher in association with peripheral P4 concentrations greater than 4 ng/ml (mid-luteal phase) when compared with lower peripheral P4 concentrations. The VT was more significantly (P<0.01) correlated to the CT, UBT and UHTs than RT. In conclusion, a temperature gradient was present among the vagina, cervix and uterus over the estrous cycle, and changes in peripheral P4 concentrations were associated with the thermal variations within these portions. The VT could be more beneficial than RT in monitoring temperature of deeper portions of the female genital tract in bovine. PMID:23095515

  7. Estimation of critical end-test torque using neuromuscular electrical stimulation of the quadriceps in humans.

    PubMed

    Janzen, Natalie R; Hight, Robert E; Patel, Darshit S; Campbell, Jason A; Larson, Rebecca D; Black, Christopher D

    2018-05-02

    Characterization of critical power/torque (CP/CT) during voluntary exercise requires maximal effort, making difficult for those with neuromuscular impairments. To address this issue we sought to determine if electrically stimulated intermittent isometric exercise resulted in a critical end-test torque (ETT) that behaved similar to voluntary CT. In the first experiment participants (n = 9) completed four bouts of stimulated exercise at a 3:2 duty cycle, at frequencies of 100, 50, 25 Hz, and a low frequency below ETT (Sub-ETT; ≤ 15 Hz). The second experiment (n = 20) consisted of four bouts at a 2:2 duty cycle-two bouts at 100 Hz, one at an intermediate frequency (15-30 Hz), and one at Sub-ETT. The third experiment (n = 12) consisted of two bouts at 50 Hz at a 3:2 duty* cycle with proximal blood flow occlusion during one of the bouts. ETT torque was similar (p ≥ 0.43) within and among stimulation frequencies in experiment 1. No fatigue was observed during the Sub-ETT bouts (p > 0.05). For experiment 2, ETT was similar at 100 Hz and at the intermediate frequency (p ≥ 0.29). Again, Sub-ETT stimulation did not result in fatigue (p > 0.05). Altering oxygen delivery by altering the duty cycle (3:2 vs. 2:2; p = 0.02) and by occlusion (p < 0.001) resulted in lower ETT values. Stimulated exercise resulted in an ETT that was consistent from day-to-day and similar regardless of initial torque, as long as that torque exceeded ETT, and was sensitive to oxygen delivery. As such we propose it represents a parameter similar to voluntary CT.

  8. Measurement and Modeling of Fugitive Dust from Off Road DoD Activities

    DTIC Science & Technology

    2017-12-08

    each soil and vehicle type (see Table 2). Note, no tracked vehicles were run at YTC. CT is the curve track sampling location, CR is the curve ridge...Soil is SL = sandy loam. ...................... 116 Figure 35. Single-event Wind Erosion Evaluation Program (SWEEP) Run example results. ... 121...Figure 36. Single-event Wind Erosion Evaluation Program (SWEEP) Threshold Run example results screen

  9. Optimizing computer-aided colonic polyp detection for CT colonography by evolving the Pareto front1

    PubMed Central

    Li, Jiang; Huang, Adam; Yao, Jack; Liu, Jiamin; Van Uitert, Robert L.; Petrick, Nicholas; Summers, Ronald M.

    2009-01-01

    A multiobjective genetic algorithm is designed to optimize a computer-aided detection (CAD) system for identifying colonic polyps. Colonic polyps appear as elliptical protrusions on the inner surface of the colon. Curvature-based features for colonic polyp detection have proved to be successful in several CT colonography (CTC) CAD systems. Our CTC CAD program uses a sequential classifier to form initial polyp detections on the colon surface. The classifier utilizes a set of thresholds on curvature-based features to cluster suspicious colon surface regions into polyp candidates. The thresholds were previously chosen experimentally by using feature histograms. The chosen thresholds were effective for detecting polyps sized 10 mm or larger in diameter. However, many medium-sized polyps, 6–9 mm in diameter, were missed in the initial detection procedure. In this paper, the task of finding optimal thresholds as a multiobjective optimization problem was formulated, and a genetic algorithm to solve it was utilized by evolving the Pareto front of the Pareto optimal set. The new CTC CAD system was tested on 792 patients. The sensitivities of the optimized system improved significantly, from 61.68% to 74.71% with an increase of 13.03% (95% CI [6.57%, 19.5%], p=7.78×10−5) for the size category of 6–9 mm polyps, from 65.02% to 77.4% with an increase of 12.38% (95% CI [6.23%, 18.53%], p=7.95×10−5) for polyps 6 mm or larger, and from 82.2% to 90.58% with an increase of 8.38% (95%CI [0.75%, 16%], p=0.03) for polyps 8 mm or larger at comparable false positive rates. The sensitivities of the optimized system are nearly equivalent to those of expert radiologists. PMID:19235388

  10. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, JM; Samei, E; Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistencymore » and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.« less

  11. CT derived left atrial size identifies left heart disease in suspected pulmonary hypertension: Derivation and validation of predictive thresholds.

    PubMed

    Currie, Benjamin J; Johns, Chris; Chin, Matthew; Charalampopolous, Thanos; Elliot, Charlie A; Garg, Pankaj; Rajaram, Smitha; Hill, Catherine; Wild, Jim W; Condliffe, Robin A; Kiely, David G; Swift, Andy J

    2018-06-01

    Patients with pulmonary hypertension due to left heart disease (PH-LHD) have overlapping clinical features with pulmonary arterial hypertension making diagnosis reliant on right heart catheterization (RHC). This study aimed to investigate computed tomography pulmonary angiography (CTPA) derived cardiopulmonary structural metrics, in comparison to magnetic resonance imaging (MRI) for the diagnosis of left heart disease in patients with suspected pulmonary hypertension. Patients with suspected pulmonary hypertension who underwent CTPA, MRI and RHC were identified. Measurements of the cardiac chambers and vessels were recorded from CTPA and MRI. The diagnostic thresholds of individual measurements to detect elevated pulmonary arterial wedge pressure (PAWP) were identified in a derivation cohort (n = 235). Individual CT and MRI derived metrics were tested in validation cohort (n = 211). 446 patients, of which 88 had left heart disease. Left atrial area was a strong predictor of elevated PAWP>15 mm Hg and PAWP>18 mm Hg, area under curve (AUC) 0.854, and AUC 0.873 respectively. Similar accuracy was also identified for MRI derived LA volume, AUC 0.852 and AUC 0.878 for PAWP > 15 and 18 mm Hg, respectively. Left atrial area of 26.8 cm 2 and 30.0 cm 2 were optimal specific thresholds for identification of PAWP > 15 and 18 mm Hg, had sensitivity of 60%/53% and specificity 89%/94%, respectively in a validation cohort. CTPA and MRI derived left atrial size identifies left heart disease in suspected pulmonary hypertension with high specificity. The proposed diagnostic thresholds for elevated left atrial area on routine CTPA may be a useful to indicate the diagnosis of left heart disease in suspected pulmonary hypertension. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  12. MO-F-CAMPUS-J-05: Using 2D Relative Gamma Analysis From EPID Image as a Predictor of Plan Deterioration Due to Anatomical Changes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piron, O; Varfalvy, N; Archambault, L

    2015-06-15

    Purpose: One of the side effects of radiotherapy for head and neck (H&N) cancer is the patient’s anatomical changes. The changes can strongly affect the planned dose distribution. In this work, our goal is to demonstrate that relative analysis of EPID images is a fast and simple method to detect anatomical changes that can have a strong dosimetric impact on the treatment plan for H&N patients. Methods: EPID images were recorded at every beam and all fractions for 50 H&N patients. Of these, five patients that showed important anatomical changes were selected to evaluate dosimetric impacts of these changes andmore » to correlate them with a 2D relative gamma analysis of EPID images. The planning CT and original contours were deformed onto CBCTs (one mid treatment and one at the end of treatment). By using deformable image registration, it was possible to map accurate CT numbers from the planning CT to the anatomy of the day obtained with CBCTs. Clinical treatment plan were then copied on the deformed dataset and dose was re-computed. In parallel, EPID images were analysed using the gamma index (3%3mm) relative to the first image. Results: It was possible to divide patients in two distinct, statistically different (p<0.001) categories using an average gamma index of 0.5 as a threshold. Below this threshold no significant dosimetric degradation of the plan are observed. Above this threshold two types of plan deterioration were seen: (1) target dose increases, but coverage remains adequate while dose to at least one OAR increases beyond tolerances; (2) the OAR doses remain low, but the target dose is reduced and coverage becomes inadequate. Conclusion: Relative analysis gamma of EPID images could indeed be a fast and simple method to detect anatomical changes that can potentially deteriorates treatment plan for H&N patients. This work was supported in part by Varian Medical System.« less

  13. A “loop” shape descriptor and its application to automated segmentation of airways from CT scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pu, Jiantao; Jin, Chenwang, E-mail: jcw76@163.com; Yu, Nan

    2015-06-15

    Purpose: A novel shape descriptor is presented to aid an automated identification of the airways depicted on computed tomography (CT) images. Methods: Instead of simplifying the tubular characteristic of the airways as an ideal mathematical cylindrical or circular shape, the proposed “loop” shape descriptor exploits the fact that the cross sections of any tubular structure (regardless of its regularity) always appear as a loop. In implementation, the authors first reconstruct the anatomical structures in volumetric CT as a three-dimensional surface model using the classical marching cubes algorithm. Then, the loop descriptor is applied to locate the airways with a concavemore » loop cross section. To deal with the variation of the airway walls in density as depicted on CT images, a multiple threshold strategy is proposed. A publicly available chest CT database consisting of 20 CT scans, which was designed specifically for evaluating an airway segmentation algorithm, was used for quantitative performance assessment. Measures, including length, branch count, and generations, were computed under the aid of a skeletonization operation. Results: For the test dataset, the airway length ranged from 64.6 to 429.8 cm, the generation ranged from 7 to 11, and the branch number ranged from 48 to 312. These results were comparable to the performance of the state-of-the-art algorithms validated on the same dataset. Conclusions: The authors’ quantitative experiment demonstrated the feasibility and reliability of the developed shape descriptor in identifying lung airways.« less

  14. Reactive Strength Index: A Poor Indicator of Reactive Strength?

    PubMed

    Healy, Robin; Kenny, Ian; Harrison, Drew

    2017-11-28

    The primary aim was to assess the relationships between reactive strength measures and associated kinematic and kinetic performance variables achieved during drop jumps. A secondary aim was to highlight issues with the use of reactive strength measures as performance indicators. Twenty eight national and international level sprinters, consisting of fourteen men and women, participated in this cross-sectional analysis. Athletes performed drop jumps from a 0.3 m box onto a force platform with dependent variables contact time (CT), landing time (TLand), push-off time (TPush), flight time (FT), jump height (JH), reactive strength index (RSI, calculated as JH / CT), reactive strength ratio (RSR, calculated as FT / CT) and vertical leg spring stiffness (Kvert) recorded. Pearson's correlation test found very high to near perfect relationships between RSI and RSR (r = 0.91 to 0.97), with mixed relationships found between RSI, RSR and the key performance variables, (Men: r = -0.86 to -0.71 between RSI/RSR and CT, r = 0.80 to 0.92 between RSI/RSR and JH; Women: r = -0.85 to -0.56 between RSR and CT, r = 0.71 between RSI and JH). This study demonstrates that the method of assessing reactive strength (RSI versus RSR) may be influenced by the performance strategies adopted i.e. whether an athlete achieves their best reactive strength scores via low CTs, high JHs or a combination. Coaches are advised to limit the variability in performance strategies by implementing upper and / or lower CT thresholds to accurately compare performances between individuals.

  15. Peripleural lung disease detection based on multi-slice CT images

    NASA Astrophysics Data System (ADS)

    Matsuhiro, M.; Suzuki, H.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.

    2015-03-01

    With the development of multi-slice CT technology, obtaining accurate 3D images of lung field in a short time become possible. To support that, a lot of image processing methods need to be developed. Detection peripleural lung disease is difficult due to its existence out of lung region, because lung extraction is often performed based on threshold processing. The proposed method uses thoracic inner region extracted by inner cavity of bone as well as air region, covers peripleural lung diseased cases such as lung nodule, calcification, pleural effusion and pleural plaque. We applied this method to 50 cases including 39 peripleural lung diseased cases. This method was able to detect 39 peripleural lung disease with 2.9 false positive per case.

  16. Non-linear responses of glaciated prairie wetlands to climate warming

    USGS Publications Warehouse

    Johnson, W. Carter; Werner, Brett; Guntenspergen, Glenn R.

    2016-01-01

    The response of ecosystems to climate warming is likely to include threshold events when small changes in key environmental drivers produce large changes in an ecosystem. Wetlands of the Prairie Pothole Region (PPR) are especially sensitive to climate variability, yet the possibility that functional changes may occur more rapidly with warming than expected has not been examined or modeled. The productivity and biodiversity of these wetlands are strongly controlled by the speed and completeness of a vegetation cover cycle driven by the wet and dry extremes of climate. Two thresholds involving duration and depth of standing water must be exceeded every few decades or so to complete the cycle and to produce highly functional wetlands. Model experiments at 19 weather stations employing incremental warming scenarios determined that wetland function across most of the PPR would be diminished beyond a climate warming of about 1.5–2.0 °C, a critical temperature threshold range identified in other climate change studies.

  17. Factors affecting performance in an ultraendurance triathlon.

    PubMed

    Laursen, P B; Rhodes, E C

    2001-01-01

    In the recent past, researchers have found many key physiological variables that correlate highly with endurance performance. These include maximal oxygen uptake (VO2max), anaerobic threshold (AT), economy of motion and the fractional utilisation of oxygen uptake (VO2). However, beyond typical endurance events such as the marathon, termed 'ultraendurance' (i.e. >4 hours), performance becomes harder to predict. The ultraendurance triathlon (UET) is a 3-sport event consisting of a 3.8 km swim and a 180 km cycle, followed by a 42.2 km marathon run. It has been hypothesised that these triathletes ride at approximately their ventilatory threshold (Tvent) during the UET cycling phase. However, laboratory assessments of cycling time to exhaustion at a subject's AT peak at 255 minutes. This suggests that the AT is too great an intensity to be maintained during a UET, and that other factors cause detriments in prolonged performance. Potential defeating factors include the provision of fuels and fluids due to finite gastric emptying rates causing changes in substrate utilisation, as well as fluid and electrolyte imbalances. Thus, an optimum ultraendurance intensity that may be relative to the AT intensity is needed to establish ultraendurance intensity guidelines. This optimal UET intensity could be referred to as the ultraendurance threshold.

  18. Three-dimensional automatic computer-aided evaluation of pleural effusions on chest CT images

    NASA Astrophysics Data System (ADS)

    Bi, Mark; Summers, Ronald M.; Yao, Jianhua

    2011-03-01

    The ability to estimate the volume of pleural effusions is desirable as it can provide information about the severity of the condition and the need for thoracentesis. We present here an improved version of an automated program to measure the volume of pleural effusions using regular chest CT images. First, the lungs are segmented using region growing, mathematical morphology, and anatomical knowledge. The visceral and parietal layers of the pleura are then extracted based on anatomical landmarks, curve fitting and active contour models. The liver and compressed tissues are segmented out using thresholding. The pleural space is then fitted to a Bezier surface which is subsequently projected onto the individual two-dimensional slices. Finally, the volume of the pleural effusion is quantified. Our method was tested on 15 chest CT studies and validated against three separate manual tracings. The Dice coefficients were 0.74+/-0.07, 0.74+/-0.08, and 0.75+/-0.07 respectively, comparable to the variation between two different manual tracings.

  19. MO-F-CAMPUS-J-04: Tissue Segmentation-Based MR Electron Density Mapping Method for MR-Only Radiation Treatment Planning of Brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, H; Lee, Y; Ruschin, M

    2015-06-15

    Purpose: Automatically derive electron density of tissues using MR images and generate a pseudo-CT for MR-only treatment planning of brain tumours. Methods: 20 stereotactic radiosurgery (SRS) patients’ T1-weighted MR images and CT images were retrospectively acquired. First, a semi-automated tissue segmentation algorithm was developed to differentiate tissues with similar MR intensities and large differences in electron densities. The method started with approximately 12 slices of manually contoured spatial regions containing sinuses and airways, then air, bone, brain, cerebrospinal fluid (CSF) and eyes were automatically segmented using edge detection and anatomical information including location, shape, tissue uniformity and relative intensity distribution.more » Next, soft tissues - muscle and fat were segmented based on their relative intensity histogram. Finally, intensities of voxels in each segmented tissue were mapped into their electron density range to generate pseudo-CT by linearly fitting their relative intensity histograms. Co-registered CT was used as a ground truth. The bone segmentations of pseudo-CT were compared with those of co-registered CT obtained by using a 300HU threshold. The average distances between voxels on external edges of the skull of pseudo-CT and CT in three axial, coronal and sagittal slices with the largest width of skull were calculated. The mean absolute electron density (in Hounsfield unit) difference of voxels in each segmented tissues was calculated. Results: The average of distances between voxels on external skull from pseudo-CT and CT were 0.6±1.1mm (mean±1SD). The mean absolute electron density differences for bone, brain, CSF, muscle and fat are 78±114 HU, and 21±8 HU, 14±29 HU, 57±37 HU, and 31±63 HU, respectively. Conclusion: The semi-automated MR electron density mapping technique was developed using T1-weighted MR images. The generated pseudo-CT is comparable to that of CT in terms of anatomical position of tissues and similarity of electron density assignment. This method can allow MR-only treatment planning.« less

  20. Extreme 13C depletions in seawater-derived brines and their implications for the past geochemical carbon cycle

    NASA Astrophysics Data System (ADS)

    Lazar, Boaz; Erez, Jonathan

    1990-12-01

    Extreme depletions in the 13C content of the total dissolved inorganic carbon (CT) were found in brines overlying microbial mat communities. Total alkalinity (AT) and CT in the brines suggest that intense photosynthetic activity of the microbial mat communities depletes the CT from the brine. We suggest that this depletion drives a large, kinetic, negative fractionation of carbon isotopes similar to that observed in highly alkaline solutions. In brines of extreme salinity where microbial mat communities no longer exist, the 13C content of the CT increases, probably because photosynthesis no longer dominates the gas-exchange processes. This mechanism explains light carbon-isotope compositions of carbonate rocks from evaporitic sections and bears on the interpretation of δ13C values in bedded stromatolitic limestones that are ca. 3.5 b.y. old.

  1. Electric stimulation of the tuberomamillary nucleus affects epileptic activity and sleep-wake cycle in a genetic absence epilepsy model.

    PubMed

    Blik, Vitaliya

    2015-01-01

    Deep brain stimulation (DBS) is a promising approach for epilepsy treatment, but the optimal targets and parameters of stimulation are yet to be investigated. Tuberomamillary nucleus (TMN) is involved in EEG desynchronization-one of the proposed mechanisms for DBS action. We studied whether TMN stimulation could interfere with epileptic spike-wave discharges (SWDs) in WAG/Rij rats with inherited absence epilepsy and whether such stimulation would affect sleep-wake cycle. EEG and video registration were used to determine SWD occurrence and stages of sleep and wake during three-hours recording sessions. Stimulation (100Hz) was applied in two modes: closed-loop (with previously determined interruption threshold intensity) or open-loop mode (with 50% or 70% threshold intensity). Closed-loop stimulation successfully interrupted SWDs but elevated their number by 148 ± 54% compared to baseline. It was accompanied by increase in number of episodes but not total duration of both active and passive wakefulness. Open-loop stimulation with amplitude 50% threshold did not change measured parameters, though 70% threshold stimulation reduced SWDs number by 40 ± 9%, significantly raised the amount of active wakefulness and decreased the amount of both slow-wave and rapid eye movement sleep. These results suggest that the TMN is unfavorable as a target for DBS as its stimulation may cause alterations in sleep-wake cycle. A careful choosing of parameters and control of sleep-wake activity is necessary when applying DBS in epilepsy. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    PubMed Central

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe

    2015-01-01

    Purpose We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method. PMID:25793178

  3. Adaptive quantification and longitudinal analysis of pulmonary emphysema with a hidden Markov measure field model.

    PubMed

    Hame, Yrjo; Angelini, Elsa D; Hoffman, Eric A; Barr, R Graham; Laine, Andrew F

    2014-07-01

    The extent of pulmonary emphysema is commonly estimated from CT scans by computing the proportional area of voxels below a predefined attenuation threshold. However, the reliability of this approach is limited by several factors that affect the CT intensity distributions in the lung. This work presents a novel method for emphysema quantification, based on parametric modeling of intensity distributions and a hidden Markov measure field model to segment emphysematous regions. The framework adapts to the characteristics of an image to ensure a robust quantification of emphysema under varying CT imaging protocols, and differences in parenchymal intensity distributions due to factors such as inspiration level. Compared to standard approaches, the presented model involves a larger number of parameters, most of which can be estimated from data, to handle the variability encountered in lung CT scans. The method was applied on a longitudinal data set with 87 subjects and a total of 365 scans acquired with varying imaging protocols. The resulting emphysema estimates had very high intra-subject correlation values. By reducing sensitivity to changes in imaging protocol, the method provides a more robust estimate than standard approaches. The generated emphysema delineations promise advantages for regional analysis of emphysema extent and progression.

  4. Automated segmentations of skin, soft-tissue, and skeleton, from torso CT images

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Hara, Takeshi; Fujita, Hiroshi; Yokoyama, Ryujiro; Kiryu, Takuji; Hoshi, Hiroaki

    2004-05-01

    We have been developing a computer-aided diagnosis (CAD) scheme for automatically recognizing human tissue and organ regions from high-resolution torso CT images. We show some initial results for extracting skin, soft-tissue and skeleton regions. 139 patient cases of torso CT images (male 92, female 47; age: 12-88) were used in this study. Each case was imaged with a common protocol (120kV/320mA) and covered the whole torso with isotopic spatial resolution of about 0.63 mm and density resolution of 12 bits. A gray-level thresholding based procedure was applied to separate the human body from background. The density and distance features to body surface were used to determine the skin, and separate soft-tissue from the others. A 3-D region growing based method was used to extract the skeleton. We applied this system to the 139 cases and found that the skin, soft-tissue and skeleton regions were recognized correctly for 93% of the patient cases. The accuracy of segmentation results was acceptable by evaluating the results slice by slice. This scheme will be included in CAD systems for detecting and diagnosing the abnormal lesions in multi-slice torso CT images.

  5. SU-G-JeP2-01: A New Approach for MR-Only Treatment Planning: Tissue Segmentation-Based Pseudo-CT Generation Using T1-Weighted MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, H; Leszczynski, K; Lee, Y

    Purpose: To evaluate MR-only treatment planning for brain Stereotactic Ablative Radiotherapy (SABR) based on pseudo-CT (pCT) generation using one set of T1-weighted MRI. Methods: T1-weighted MR and CT images from 12 patients who were eligible for brain SABR were retrospectively acquired for this study. MR-based pCT was generated by using a newly in-house developed algorithm based on MR tissue segmentation and voxel-based electron density (ED) assignment (pCTv). pCTs using bulk density assignment (pCTb where bone and soft tissue were assigned 800HU and 0HU,respectively), and water density assignment (pCTw where all tissues were assigned 0HU) were generated for comparison of EDmore » assignment techniques. The pCTs were registered with CTs and contours of radiation targets and Organs-at-Risk (OARs) from clinical CT-based plans were copied to co-registered pCTs. Volumetric-Modulated-Arc-Therapy(VMAT) plans were independently created for pCTv and CT using the same optimization settings and a prescription (50Gy/10 fractions) to planning-target-volume (PTV) mean dose. pCTv-based plans and CT-based plans were compared with dosimetry parameters and monitor units (MUs). Beam fluence maps of CT-based plans were transferred to co-registered pCTs, and dose was recalculated on pCTs. Dose distribution agreement between pCTs and CT plans were quantified using Gamma analysis (2%/2mm, 1%/1mm with a 10% cut-off threshold) in axial, coronal and sagittal planes across PTV. Results: The average differences of PTV mean and maximum doses, and monitor units between independently created pCTv-based and CT-based plans were 0.5%, 1.5% and 1.1%, respectively. Gamma analysis of dose distributions of the pCTs and the CT calculated using the same fluence map resulted in average agreements of 92.6%/79.1%/52.6% with 1%/1mm criterion, and 98.7%/97.4%/71.5% with 2%/2mm criterion, for pCTv/CT, pCTb/CT and pCTw/CT, respectively. Conclusion: Plans produced on Voxel-based pCT is dosimetrically more similar to CT plans than bulk assignment-based pCTs. MR-only treatment planning using voxel-based pCT generated from T1-wieghted MRI may be feasible.« less

  6. Non-rigid registration of serial dedicated breast CT, longitudinal dedicated breast CT and PET/CT images using the diffeomorphic demons method.

    PubMed

    Santos, Jonathan; Chaudhari, Abhijit J; Joshi, Anand A; Ferrero, Andrea; Yang, Kai; Boone, John M; Badawi, Ramsey D

    2014-09-01

    Dedicated breast CT and PET/CT scanners provide detailed 3D anatomical and functional imaging data sets and are currently being investigated for applications in breast cancer management such as diagnosis, monitoring response to therapy and radiation therapy planning. Our objective was to evaluate the performance of the diffeomorphic demons (DD) non-rigid image registration method to spatially align 3D serial (pre- and post-contrast) dedicated breast computed tomography (CT), and longitudinally-acquired dedicated 3D breast CT and positron emission tomography (PET)/CT images. The algorithmic parameters of the DD method were optimized for the alignment of dedicated breast CT images using training data and fixed. The performance of the method for image alignment was quantitatively evaluated using three separate data sets; (1) serial breast CT pre- and post-contrast images of 20 women, (2) breast CT images of 20 women acquired before and after repositioning the subject on the scanner, and (3) dedicated breast PET/CT images of 7 women undergoing neo-adjuvant chemotherapy acquired pre-treatment and after 1 cycle of therapy. The DD registration method outperformed no registration (p < 0.001) and conventional affine registration (p ≤ 0.002) for serial and longitudinal breast CT and PET/CT image alignment. In spite of the large size of the imaging data, the computational cost of the DD method was found to be reasonable (3-5 min). Co-registration of dedicated breast CT and PET/CT images can be performed rapidly and reliably using the DD method. This is the first study evaluating the DD registration method for the alignment of dedicated breast CT and PET/CT images. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. [Determination of the anaerobic threshold by the rate of ventilation and cardio interval variability].

    PubMed

    Seluianov, V N; Kalinin, E M; Pak, G D; Maevskaia, V I; Konrad, A H

    2011-01-01

    The aim of this work is to develop methods for determining the anaerobic threshold according to the rate of ventilation and cardio interval variability during the test with stepwise increases load on the cycle ergometer and treadmill. In the first phase developed the method for determining the anaerobic threshold for lung ventilation. 49 highly skilled skiers took part in the experiment. They performed a treadmill ski-walking test with sticks with gradually increasing slope from 0 to 25 degrees, the slope increased by one degree every minute. In the second phase we developed a method for determining the anaerobic threshold according dynamics ofcardio interval variability during the test. The study included 86 athletes of different sports specialties who performed pedaling on the cycle ergometer "Monarch" in advance. Initial output was 25 W, power increased by 25 W every 2 min. The pace was steady--75 rev/min. Measurement of pulmonary ventilation and oxygen and carbon dioxide content was performed using gas analyzer COSMED K4. Sampling of arterial blood was carried from the ear lobe or finger, blood lactate concentration was determined using an "Akusport" instrument. RR-intervals registration was performed using heart rate monitor Polar s810i. As a result, it was shown that the graphical method for determining the onset of anaerobic threshold ventilation (VAnP) coincides with the accumulation of blood lactate 3.8 +/- 0.1 mmol/l when testing on a treadmill and 4.1 +/- 0.6 mmol/1 on the cycle ergometer. The connection between the measure of oxygen consumption at VAnP and the dispersion of cardio intervals (SD1), derived regression equation: VO2AnT = 0.35 + 0.01SD1W + 0.0016SD1HR + + 0.106SD1(ms), l/min; (R = 0.98, error evaluation function 0.26 L/min, p < 0.001), where W (W)--Power, HR--heart rate (beats/min), SD1--cardio intervals dispersion (ms) at the moment of registration of cardio interval threshold.

  8. Flexible lithium–oxygen battery based on a recoverable cathode

    PubMed Central

    Liu, Qing-Chao; Xu, Ji-Jing; Xu, Dan; Zhang, Xin-Bo

    2015-01-01

    Although flexible power sources are crucial for the realization next-generation flexible electronics, their application in such devices is hindered by their low theoretical energy density. Rechargeable lithium–oxygen (Li–O2) batteries can provide extremely high specific energies, while the conventional Li–O2 battery is bulky, inflexible and limited by the absence of effective components and an adjustable cell configuration. Here we show that a flexible Li–O2 battery can be fabricated using unique TiO2 nanowire arrays grown onto carbon textiles (NAs/CT) as a free-standing cathode and that superior electrochemical performances can be obtained even under stringent bending and twisting conditions. Furthermore, the TiO2 NAs/CT cathode features excellent recoverability, which significantly extends the cycle life of the Li–O2 battery and lowers its life cycle cost. PMID:26235205

  9. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    PubMed

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P < 0.05), and PLTA (34.9 ± 10.5° vs 25.7 ± 3.4°, P = 0.001). Furthermore, the evaluation of ROC analysis showed that the AUC of BOI was the largest (AUC = 0.906) among the three parameters, and the optimal threshold of BOI to predict the positive patellar J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive patellar J sign. IV.

  10. A post-reconstruction method to correct cupping artifacts in cone beam breast computed tomography

    PubMed Central

    Altunbas, M. C.; Shaw, C. C.; Chen, L.; Lai, C.; Liu, X.; Han, T.; Wang, T.

    2007-01-01

    In cone beam breast computed tomography (CT), scattered radiation leads to nonuniform biasing of CT numbers known as a cupping artifact. Besides being visual distractions, cupping artifacts appear as background nonuniformities, which impair efficient gray scale windowing and pose a problem in threshold based volume visualization/segmentation. To overcome this problem, we have developed a background nonuniformity correction method specifically designed for cone beam breast CT. With this technique, the cupping artifact is modeled as an additive background signal profile in the reconstructed breast images. Due to the largely circularly symmetric shape of a typical breast, the additive background signal profile was also assumed to be circularly symmetric. The radial variation of the background signals were estimated by measuring the spatial variation of adipose tissue signals in front view breast images. To extract adipose tissue signals in an automated manner, a signal sampling scheme in polar coordinates and a background trend fitting algorithm were implemented. The background fits compared with targeted adipose tissue signal value (constant throughout the breast volume) to get an additive correction value for each tissue voxel. To test the accuracy, we applied the technique to cone beam CT images of mastectomy specimens. After correction, the images demonstrated significantly improved signal uniformity in both front and side view slices. The reduction of both intra-slice and inter-slice variations in adipose tissue CT numbers supported our observations. PMID:17822018

  11. Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm.

    PubMed

    Pansini, Vittorio; Remy-Jardin, Martine; Tacelli, Nunzia; Faivre, Jean-Baptiste; Flohr, Thomas; Deken, Valérie; Duhamel, Alain; Remy, Jacques

    2008-10-01

    To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P=0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P

  12. Assessing the prevalence and clinical relevance of positive abdominal and pelvic CT findings in senior patients presenting to the emergency department.

    PubMed

    Alabousi, Abdullah; Patlas, Michael N; Meshki, Malek; Monteiro, Sandra; Katz, Douglas S

    2016-04-01

    The purpose of our study was to retrospectively evaluate the prevalence and clinical relevance of positive abdominal and pelvic CT findings for patients 65 years of age and older, when compared with all other scanned adult Emergency Department (ED) patients, at a single tertiary care hospital. Our hypothesis was that there is an increased prevalence and clinical relevance of positive abdominal/pelvic CT findings in senior patients. A research ethics board-approved retrospective review of all adult patients who underwent an emergency CT of the abdomen and pelvis for acute nontraumatic abdominal and/or pelvic signs and symptoms was performed. Two thousand one hundred two patients between October 1, 2011, and September 30, 2013, were reviewed. Six hundred thirty-one patients were included in the <65 group (298 men and 333 women; mean age 46, age range 18-64), and 462 were included in the >65 group (209 men and 253 women; mean age 77.6, age range 65-99). Overall, there were more positive CT findings for patients <65 (389 positive cases, 61.6 %) compared with the >65 group (257 positive cases, 55.6 %), which was a statistically significant difference (p < 0.03). Moreover, with the exception of complicated appendicitis cases, which were more common in the >65 group, there were no statistically significant differences in the clinical/surgical relevance of the positive CT findings between the two groups. The findings of our retrospective study therefore refute our hypothesis that there is an increased prevalence of positive abdominal CT findings in patients >65. This may be related to ED physicians at our institution being more hesitant to order CT examinations for the younger population, presumably due to radiation concerns. However, older patients in our series were more likely to present with complicated appendicitis, and a lower threshold for ordering CT examinations of the abdomen and pelvis in this patient population should therefore be considered.

  13. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

    PubMed

    Morsbach, Fabian; Bickelhaupt, Sebastian; Wanner, Guido A; Krauss, Andreas; Schmidt, Bernhard; Alkadhi, Hatem

    2013-07-01

    To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P < .001) more accurate for IFS when compared with filtered back projection. In patients, best overall and pelvic organ image quality was found in all reformations with IFS (P < .001). Pelvic abnormalities in 11 of 41 patients (27%) were diagnosed with significantly (P = .002) higher confidence on the basis of IFS images. CT attenuation of bladder (P < .001) and muscle (P = .043) was significantly less variable with IFS compared with filtered back projection and linear interpolation MAR. In comparison with that of FBP and linear interpolation MAR, noise with IFS was similar close to and far from the prosthesis (P = .295). The IFS algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.

  14. Quantitative micro-CT based coronary artery profiling using interactive local thresholding and cylindrical coordinates.

    PubMed

    Panetta, Daniele; Pelosi, Gualtiero; Viglione, Federica; Kusmic, Claudia; Terreni, Marianna; Belcari, Nicola; Guerra, Alberto Del; Athanasiou, Lambros; Exarchos, Themistoklis; Fotiadis, Dimitrios I; Filipovic, Nenad; Trivella, Maria Giovanna; Salvadori, Piero A; Parodi, Oberdan

    2015-01-01

    Micro-CT is an established imaging technique for high-resolution non-destructive assessment of vascular samples, which is gaining growing interest for investigations of atherosclerotic arteries both in humans and in animal models. However, there is still a lack in the definition of micro-CT image metrics suitable for comprehensive evaluation and quantification of features of interest in the field of experimental atherosclerosis (ATS). A novel approach to micro-CT image processing for profiling of coronary ATS is described, providing comprehensive visualization and quantification of contrast agent-free 3D high-resolution reconstruction of full-length artery walls. Accelerated coronary ATS has been induced by high fat cholesterol-enriched diet in swine and left coronary artery (LCA) harvested en bloc for micro-CT scanning and histologic processing. A cylindrical coordinate system has been defined on the image space after curved multiplanar reformation of the coronary vessel for the comprehensive visualization of the main vessel features such as wall thickening and calcium content. A novel semi-automatic segmentation procedure based on 2D histograms has been implemented and the quantitative results validated by histology. The potentiality of attenuation-based micro-CT at low kV to reliably separate arterial wall layers from adjacent tissue as well as identify wall and plaque contours and major tissue components has been validated by histology. Morphometric indexes from histological data corresponding to several micro-CT slices have been derived (double observer evaluation at different coronary ATS stages) and highly significant correlations (R2 > 0.90) evidenced. Semi-automatic morphometry has been validated by double observer manual morphometry of micro-CT slices and highly significant correlations were found (R2 > 0.92). The micro-CT methodology described represents a handy and reliable tool for quantitative high resolution and contrast agent free full length coronary wall profiling, able to assist atherosclerotic vessels morphometry in a preclinical experimental model of coronary ATS and providing a link between in vivo imaging and histology.

  15. Implications of Use of Coal-Tar-Based Pavement Sealcoat on Urban Water Quality

    NASA Astrophysics Data System (ADS)

    Van Metre, P. C.

    2015-12-01

    Coal-tar-based (CT) sealcoat is used to protect and improve the appearance of asphalt pavement of driveways and parking lots primarily in the central and eastern U.S. and in Canada. CT sealcoat typically is 20 to 35% crude coal tar or coal-tar pitch and contains from 50,000 to 100,000 mg/kg polycyclic aromatic hydrocarbons (PAH), about 1,000 times more than asphalt-based (AS) sealcoat or asphalt itself. Tires and snowplows abrade the friable sealcoat surface into fine particles—median total PAH concentrations in dust from CT-sealcoated pavement are 2,200 mg/kg compared to a median concentration of 11 mg/kg for dust from unsealed pavement. Use of CT sealcoat has several implications for urban streams and lakes. Source apportionment modeling has indicated that, in regions where CT sealcoat is prevalent, particles from sealcoated pavement are contributing the majority of the PAHs to recently deposited lake sediment, often resulting in sediment concentrations above toxicity thresholds based on effects-based sediment quality guidelines. Acute 2-day laboratory toxicity testing of simulated runoff from CT-sealcoated pavement to a cladoceran (Ceriodaphnia dubia) and fathead minnows (Pimephales promelas) demonstrated that toxicity continues for samples collected for weeks or months following sealcoat application and that toxicity is enhanced by exposure to UV light. Using the fish-liver cell line RTL-W1, runoff collected as much as 36 days following CT-sealcoat application has been demonstrated to cause DNA damage and impair DNA repair capacity. These results demonstrate that CT runoff is a potential hazard to aquatic ecosystems and that exposure to sunlight can enhance toxicity and genetic damage. Recent research has provided direct evidence that restricting use of CT sealcoat in a watershed can lead to a substantial reduction in PAH concentrations in receiving water bodies.

  16. Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT.

    PubMed

    Isola, A A; Schmitt, H; van Stevendaal, U; Begemann, P G; Coulon, P; Boussel, L; Grass, M

    2011-09-21

    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.

  17. A combined learning algorithm for prostate segmentation on 3D CT images.

    PubMed

    Ma, Ling; Guo, Rongrong; Zhang, Guoyi; Schuster, David M; Fei, Baowei

    2017-11-01

    Segmentation of the prostate on CT images has many applications in the diagnosis and treatment of prostate cancer. Because of the low soft-tissue contrast on CT images, prostate segmentation is a challenging task. A learning-based segmentation method is proposed for the prostate on three-dimensional (3D) CT images. We combine population-based and patient-based learning methods for segmenting the prostate on CT images. Population data can provide useful information to guide the segmentation processing. Because of inter-patient variations, patient-specific information is particularly useful to improve the segmentation accuracy for an individual patient. In this study, we combine a population learning method and a patient-specific learning method to improve the robustness of prostate segmentation on CT images. We train a population model based on the data from a group of prostate patients. We also train a patient-specific model based on the data of the individual patient and incorporate the information as marked by the user interaction into the segmentation processing. We calculate the similarity between the two models to obtain applicable population and patient-specific knowledge to compute the likelihood of a pixel belonging to the prostate tissue. A new adaptive threshold method is developed to convert the likelihood image into a binary image of the prostate, and thus complete the segmentation of the gland on CT images. The proposed learning-based segmentation algorithm was validated using 3D CT volumes of 92 patients. All of the CT image volumes were manually segmented independently three times by two, clinically experienced radiologists and the manual segmentation results served as the gold standard for evaluation. The experimental results show that the segmentation method achieved a Dice similarity coefficient of 87.18 ± 2.99%, compared to the manual segmentation. By combining the population learning and patient-specific learning methods, the proposed method is effective for segmenting the prostate on 3D CT images. The prostate CT segmentation method can be used in various applications including volume measurement and treatment planning of the prostate. © 2017 American Association of Physicists in Medicine.

  18. Automatic Solitary Lung Nodule Detection in Computed Tomography Images Slices

    NASA Astrophysics Data System (ADS)

    Sentana, I. W. B.; Jawas, N.; Asri, S. A.

    2018-01-01

    Lung nodule is an early indicator of some lung diseases, including lung cancer. In Computed Tomography (CT) based image, nodule is known as a shape that appears brighter than lung surrounding. This research aim to develop an application that automatically detect lung nodule in CT images. There are some steps in algorithm such as image acquisition and conversion, image binarization, lung segmentation, blob detection, and classification. Data acquisition is a step to taking image slice by slice from the original *.dicom format and then each image slices is converted into *.tif image format. Binarization that tailoring Otsu algorithm, than separated the background and foreground part of each image slices. After removing the background part, the next step is to segment part of the lung only so the nodule can localized easier. Once again Otsu algorithm is use to detect nodule blob in localized lung area. The final step is tailoring Support Vector Machine (SVM) to classify the nodule. The application has succeed detecting near round nodule with a certain threshold of size. Those detecting result shows drawback in part of thresholding size and shape of nodule that need to enhance in the next part of the research. The algorithm also cannot detect nodule that attached to wall and Lung Chanel, since it depend the searching only on colour differences.

  19. A benchmarking tool to evaluate computer tomography perfusion infarct core predictions against a DWI standard.

    PubMed

    Cereda, Carlo W; Christensen, Søren; Campbell, Bruce Cv; Mishra, Nishant K; Mlynash, Michael; Levi, Christopher; Straka, Matus; Wintermark, Max; Bammer, Roland; Albers, Gregory W; Parsons, Mark W; Lansberg, Maarten G

    2016-10-01

    Differences in research methodology have hampered the optimization of Computer Tomography Perfusion (CTP) for identification of the ischemic core. We aim to optimize CTP core identification using a novel benchmarking tool. The benchmarking tool consists of an imaging library and a statistical analysis algorithm to evaluate the performance of CTP. The tool was used to optimize and evaluate an in-house developed CTP-software algorithm. Imaging data of 103 acute stroke patients were included in the benchmarking tool. Median time from stroke onset to CT was 185 min (IQR 180-238), and the median time between completion of CT and start of MRI was 36 min (IQR 25-79). Volumetric accuracy of the CTP-ROIs was optimal at an rCBF threshold of <38%; at this threshold, the mean difference was 0.3 ml (SD 19.8 ml), the mean absolute difference was 14.3 (SD 13.7) ml, and CTP was 67% sensitive and 87% specific for identification of DWI positive tissue voxels. The benchmarking tool can play an important role in optimizing CTP software as it provides investigators with a novel method to directly compare the performance of alternative CTP software packages. © The Author(s) 2015.

  20. DEVELOPMENTAL NEUROTOXICITY OF ORGANOPHOSPHATES TARGETS CELL CYCLE AND APOPTOSIS, REVEALED BY TRANSCRIPTIONAL PROFILES IN VIVO AND IN VITRO

    PubMed Central

    Slotkin, Theodore A.; Seidler, Frederic J.

    2012-01-01

    Developmental organophosphate exposure reduces the numbers of neural cells, contributing to neurobehavioral deficits. We administered chlorpyrifos or diazinon to newborn rats on postnatal days 1–4, in doses straddling the threshold for barely-detectable cholinesterase, and evaluated gene expression in the cell cycle and apoptosis pathways on postnatal day 5. Both organophosphates evoked transcriptional changes in 20–25% of the genes in each category; chlorpyrifos and diazinon targeted the same genes, with similar magnitudes of change, as evidenced by high concordance. Furthermore, the same effects were obtained with doses above or below the threshold for cholinesterase inhibition, indicating a mechanism unrelated to anticholinesterase actions. We then evaluated the effects of chlorpyrifos in undifferentiated and differentiating PC12 cells and found even greater targeting of cell cycle and apoptosis genes, affecting up to 40% of all genes in the pathways. Notably, the genes affected in undifferentiated cells were not concordant with those in differentiating cells, pointing to dissimilar outcomes dependent on developmental stage. The in vitro model successfully identified 60–70% of the genes affected by chlorpyrifos in vivo, indicating that the effects are exerted directly on developing neural cells. Our results show that organophosphates target the genes regulating the cell cycle and apoptosis in the developing brain and in neuronotypic cells in culture, with the pattern of vulnerability dependent on the specific stage of development. Equally important, these effects do not reflect actions on cholinesterase and operate at exposures below the threshold for any detectable inhibition of this enzyme. PMID:22222554

Top