Sample records for da vinci programmiga

  1. Da Vinci-assisted abdominal cerclage.

    PubMed

    Barmat, Larry; Glaser, Gretchen; Davis, George; Craparo, Frank

    2007-11-01

    To report the first placement of an abdominal cervicoisthmic cerclage using the da Vinci robot. Case report. Tertiary-care hospital. A 39-year-old female with a history of cervical insufficiency who required a cerclage and was not a candidate for transvaginal cerclage placement. Abdominal cervicoisthmic cerclage placement using the da Vinci robot. Ability to safely and successfully place an abdominal cerclage using the da Vinci robot. Abdominal cerclage was successfully placed using the da Vinci robot. The patient had minimal blood loss and was discharged to home on the same day as surgery. Da Vinci robot-assisted abdominal cerclage placement is an innovative application of robotic surgery and may alter the standard of care for women who require this surgery.

  2. da Vinci decoded: does da Vinci stereopsis rely on disparity?

    PubMed

    Tsirlin, Inna; Wilcox, Laurie M; Allison, Robert S

    2012-11-01

    In conventional stereopsis, the depth between two objects is computed based on the retinal disparity in the position of matching points in the two eyes. When an object is occluded by another object in the scene, so that it is visible only in one eye, its retinal disparity cannot be computed. Nakayama and Shimojo (1990) found that a precept of quantitative depth between the two objects could still be established for such stimuli and proposed that this precept is based on the constraints imposed by occlusion geometry. They named this and other occlusion-based depth phenomena "da Vinci stereopsis." Subsequent research found quantitative depth based on occlusion geometry in several other classes of stimuli grouped under the term da Vinci stereopsis. However, Nakayama and Shimojo's findings were later brought into question by Gillam, Cook, and Blackburn (2003), who suggested that quantitative depth in their stimuli was perceived based on conventional disparity. In order to understand whether da Vinci stereopsis relies on one type of mechanism or whether its function is stimulus dependent we examine the nature and source of depth in the class of stimuli used by Nakayama and Shimojo (1990). We use three different psychophysical and computational methods to show that the most likely source for depth in these stimuli is occlusion geometry. Based on these experiments and previous data we discuss the potential mechanisms responsible for processing depth from monocular features in da Vinci stereopsis.

  3. The da Vinci robot.

    PubMed

    Moran, Michael E

    2006-12-01

    One might assume from the title of this paper that the nuances of a complex mechanical robot will be discussed, and this would be correct. On the other hand, the date of the design and possible construction of this robot was 1495, a little more than five centuries ago. The key point in the title is the lack of a trademarked name, as Leonardo was the designer of this sophisticated system. His notes from the Codex Altanticus represent the foundation of this report. English translations of da Vinci's notebooks are currently available. Beginning in the 1950s, investigators at the University of California began to ponder the significance of some of da Vinci's markings on what appeared to be technical drawings. Such markings also occur in his Codex Atlanticus (the largest single collection of da Vinci's sheets, consisting of 1119 separate pages and 481 folios) along with a large number of other mechanical devices. Continuing research at the Instituto e Museo di Storia della Scienza in Florence has yielded a great deal of information about Leonardo's intentions with regard to his mechanical knight. It is now known that da Vinci's robot would have had the outer appearance of a Germanic knight. It had a complex core of mechanical devices that probably was human powered. The robot had two independent operating systems. The first had three degree-of-freedom legs, ankles, knees, and hips. The second had four degrees of freedom in the arms with articulated shoulders, elbows, wrists, and hands. A mechanical analog-programmable controller within the chest provided the power and control for the arms. The legs were powered by an external crank arrangement driving the cable, which connected to key locations near each lower extremity's joints. Da Vinci also is known to have devised a programmable front-wheel-drive automobile with rack-and-pinion suspension mechanisms at age 26. He would recall this device again, when, at age 40, he is thought to have built a programmable automated

  4. Leonardo da Vinci and the Downburst.

    NASA Astrophysics Data System (ADS)

    Gedzelman, Stanley David

    1990-05-01

    Evidence from the drawings, experiments, and writings of Leonardo da Vinci are presented to demonstrate that da Vinci recognized and, possibly, discovered the downburst and understood its associated airflow. Other early references to vortex flows resembling downbursts are mentioned.

  5. Raven surgical robot training in preparation for da vinci.

    PubMed

    Glassman, Deanna; White, Lee; Lewis, Andrew; King, Hawkeye; Clarke, Alicia; Glassman, Thomas; Comstock, Bryan; Hannaford, Blake; Lendvay, Thomas S

    2014-01-01

    The rapid adoption of robotic assisted surgery challenges the pace at which adequate robotic training can occur due to access limitations to the da Vinci robot. Thirty medical students completed a randomized controlled trial evaluating whether the Raven robot could be used as an alternative training tool for the Fundamentals of Laparoscopic Surgery (FLS) block transfer task on the da Vinci robot. Two groups, one trained on the da Vinci and one trained on the Raven, were tested on a criterion FLS block transfer task on the da Vinci. After robotic FLS block transfer proficiency training there was no statistically significant difference between path length (p=0.39) and economy of motion scores (p=0.06) between the two groups, but those trained on the da Vinci did have faster task times (p=0.01). These results provide evidence for the value of using the Raven robot for training prior to using the da Vinci surgical system for similar tasks.

  6. [Clinical application of Da Vinci surgical system in China].

    PubMed

    Jin, Zhenyu

    2014-01-01

    Da Vinci robotic surgical system leads the development of minimally invasive surgical techniques. By using Da Vinci surgical robot for minimally invasive surgery, it brings a lot of advantages to the surgeons. Since 2008, Da Vinci surgeries have been performed in 14 hospitals in domestic cities such as Beijing and Shanghai. Until the end of 2012, 3 551 cases of Da Vinci robotic surgery have been performed, covering various procedures of various surgical departments including the department of general surgery, urology, cardiovascular surgery, thoracic surgery, gynecology, and etc. Robotic surgical technique has made remarkable achievements.

  7. [da Vinci surgical system].

    PubMed

    Watanabe, Gou; Ishikawa, Norihiro

    2014-07-01

    The da Vinci surgical system was developed by Intuitive Surgical Inc. in the United States as an endoscopic surgical device to assist remote control surgeries. In 1998, the Da Vinci system was first used for cardiothoracic procedures. Currently a combination of robot-assisted internal thoracic artery harvest together with coronary artery bypass grafting (CABG) through a mini-incision (ThoraCAB) or totally endoscopic procedures including anastomoses under robotic assistance (TECAB) are being conducted for the treatment of coronary artery diseases. With the recent advances in catheter interventions, hybrid procedures combining catheter intervention with ThoraCAB or TECAB are anticipated in the future.On the other hand, with the decrease in number of coronary artery bypass surgeries, the share of valvular surgeries is expected to increase in the future. Among them, mitral valvuloplasty for mitral regurgitation is anticipated to be conducted mainly by low-invasive procedures, represented by minimally invasive cardiac surgery( MICS) and robot-assisted surgery. Apart from the intrinsic good surgical view, robotic-assisted systems offer additional advantages of the availability of an amplified view and the easy to observe the mitral valve in the physiological position. Thus, robotic surgical surgeries that make complicated procedures easier are expected to accomplish further developments in the future. Furthermore, while the number of surgeries for atrial septal defects has decreased dramatically following the widespread use of Amplatzer septal occluder, robotic surgery may become a good indication for cases in which the Amplatzer device is not indicated. In Japan, clinical trial of the da Vinci robotic system for heart surgeries has been completed. Statutory approval of the da Vinci system for mitral regurgitation and atrial septal defects is anticipated in the next few years.

  8. Tree Branching: Leonardo da Vinci's Rule versus Biomechanical Models

    PubMed Central

    Minamino, Ryoko; Tateno, Masaki

    2014-01-01

    This study examined Leonardo da Vinci's rule (i.e., the sum of the cross-sectional area of all tree branches above a branching point at any height is equal to the cross-sectional area of the trunk or the branch immediately below the branching point) using simulations based on two biomechanical models: the uniform stress and elastic similarity models. Model calculations of the daughter/mother ratio (i.e., the ratio of the total cross-sectional area of the daughter branches to the cross-sectional area of the mother branch at the branching point) showed that both biomechanical models agreed with da Vinci's rule when the branching angles of daughter branches and the weights of lateral daughter branches were small; however, the models deviated from da Vinci's rule as the weights and/or the branching angles of lateral daughter branches increased. The calculated values of the two models were largely similar but differed in some ways. Field measurements of Fagus crenata and Abies homolepis also fit this trend, wherein models deviated from da Vinci's rule with increasing relative weights of lateral daughter branches. However, this deviation was small for a branching pattern in nature, where empirical measurements were taken under realistic measurement conditions; thus, da Vinci's rule did not critically contradict the biomechanical models in the case of real branching patterns, though the model calculations described the contradiction between da Vinci's rule and the biomechanical models. The field data for Fagus crenata fit the uniform stress model best, indicating that stress uniformity is the key constraint of branch morphology in Fagus crenata rather than elastic similarity or da Vinci's rule. On the other hand, mechanical constraints are not necessarily significant in the morphology of Abies homolepis branches, depending on the number of daughter branches. Rather, these branches were often in agreement with da Vinci's rule. PMID:24714065

  9. Tree branching: Leonardo da Vinci's rule versus biomechanical models.

    PubMed

    Minamino, Ryoko; Tateno, Masaki

    2014-01-01

    This study examined Leonardo da Vinci's rule (i.e., the sum of the cross-sectional area of all tree branches above a branching point at any height is equal to the cross-sectional area of the trunk or the branch immediately below the branching point) using simulations based on two biomechanical models: the uniform stress and elastic similarity models. Model calculations of the daughter/mother ratio (i.e., the ratio of the total cross-sectional area of the daughter branches to the cross-sectional area of the mother branch at the branching point) showed that both biomechanical models agreed with da Vinci's rule when the branching angles of daughter branches and the weights of lateral daughter branches were small; however, the models deviated from da Vinci's rule as the weights and/or the branching angles of lateral daughter branches increased. The calculated values of the two models were largely similar but differed in some ways. Field measurements of Fagus crenata and Abies homolepis also fit this trend, wherein models deviated from da Vinci's rule with increasing relative weights of lateral daughter branches. However, this deviation was small for a branching pattern in nature, where empirical measurements were taken under realistic measurement conditions; thus, da Vinci's rule did not critically contradict the biomechanical models in the case of real branching patterns, though the model calculations described the contradiction between da Vinci's rule and the biomechanical models. The field data for Fagus crenata fit the uniform stress model best, indicating that stress uniformity is the key constraint of branch morphology in Fagus crenata rather than elastic similarity or da Vinci's rule. On the other hand, mechanical constraints are not necessarily significant in the morphology of Abies homolepis branches, depending on the number of daughter branches. Rather, these branches were often in agreement with da Vinci's rule.

  10. The role of transparency in da Vinci stereopsis.

    PubMed

    Zannoli, Marina; Mamassian, Pascal

    2011-10-15

    The majority of natural scenes contains zones that are visible to one eye only. Past studies have shown that these monocular regions can be seen at a precise depth even though there are no binocular disparities that uniquely constrain their locations in depth. In the so-called da Vinci stereopsis configuration, the monocular region is a vertical line placed next to a binocular rectangular occluder. The opacity of the occluder has been mentioned to be a necessary condition to obtain da Vinci stereopsis. However, this opacity constraint has never been empirically tested. In the present study, we tested whether da Vinci stereopsis and perceptual transparency can interact using a classical da Vinci configuration in which the opacity of the occluder varied. We used two different monocular objects: a line and a disk. We found no effect of the opacity of the occluder on the perceived depth of the monocular object. A careful analysis of the distribution of perceived depth revealed that the monocular object was perceived at a depth that increased with the distance between the object and the occluder. The analysis of the skewness of the distributions was not consistent with a double fusion explanation, favoring an implication of occlusion geometry in da Vinci stereopsis. A simple model that includes the geometry of the scene could account for the results. In summary, the mechanism responsible to locate monocular regions in depth is not sensitive to the material properties of objects, suggesting that da Vinci stereopsis is solved at relatively early stages of disparity processing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Technical review of the da Vinci surgical telemanipulator.

    PubMed

    Freschi, C; Ferrari, V; Melfi, F; Ferrari, M; Mosca, F; Cuschieri, A

    2013-12-01

    The da Vinci robotic surgical telemanipulator has been utilized in several surgical specialties for varied procedures, and the users' experiences have been widely published. To date, no detailed system technical analyses have been performed. A detailed review was performed of all publications and patents about the technical aspects of the da Vinci robotic system. Published technical literature on the da Vinci system highlight strengths and weaknesses of the robot design. While the system facilitates complex surgical operations and has a low malfunction rate, the lack of haptic (especially tactile) feedback and collisions between the robotic arms remain the major limitations of the system. Accurate, preplanned positioning of access ports is essential. Knowledge of the technical aspects of the da Vinci robot is important for optimal use. We confirmed the excellent system functionality and ease of use for surgeons without an engineering background. Research and development of the surgical robot has been predominant in the literature. Future trends address robot miniaturization and intelligent control design. Copyright © 2012 John Wiley & Sons, Ltd.

  12. The Case: Bunche-Da Vinci Learning Partnership Academy

    ERIC Educational Resources Information Center

    Eisenberg, Nicole; Winters, Lynn; Alkin, Marvin C.

    2005-01-01

    The Bunche-Da Vinci case described in this article presents a situation at Bunche Elementary School that four theorists were asked to address in their evaluation designs (see EJ791771, EJ719772, EJ791773, and EJ792694). The Bunche-Da Vinci Learning Partnership Academy, an elementary school located between an urban port city and a historically…

  13. Da Vinci robot-assisted system for thymectomy: experience of 55 patients in China.

    PubMed

    Jun, Yi; Hao, Li; Demin, Li; Guohua, Dong; Hua, Jing; Yi, Shen

    2014-09-01

    Da Vinci robot-assisted thymectomy has been used in the past several years in China, however, practical experience in performing this approach in China remains limited. Thus, the study aimed to evaluate the experience of da Vinci robot-assisted thymectomy in China. From June 2010 to December 2012, 55 patients with diseases of the thymus underwent thymectomy using the da Vinci surgical HD robotic system. The clinical data of the da Vinci robot-assisted thymectomies were compared with the data of video-assisted thoracoscopic thymectomies in the same period. All da Vinci robot operations were successful. This is a retrospective analysis which demonstrated that compared with video-assisted thoracoscopic thymectomy in the same period, the clinical outcomes of da Vinci robot-assisted thymectomy were not significantly different. The da Vinci robot-assisted thymectomy is a safe, minimally invasive, and convenient operation, and shows promise for general thoracic surgery in China. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Use of the new da Vinci Xi® during robotic rectal resection for cancer: a pilot matched-case comparison with the da Vinci Si®.

    PubMed

    Morelli, Luca; Guadagni, Simone; Di Franco, Gregorio; Palmeri, Matteo; Caprili, Giovanni; D'Isidoro, Cristiano; Cobuccio, Luigi; Marciano, Emanuele; Di Candio, Giulio; Mosca, Franco

    2017-03-01

    The aim of this study was to compare the short-term outcomes of robotic rectal resection with total mesorectal excision (TME) for rectal cancer, with the use of the new da Vinci Xi® (Xi-RobTME group) and the da Vinci Si® (Si-RobTME group). Ten patients with histologically confirmed rectal cancer underwent robot-assisted TME with the use of the new da Vinci Xi. The outcomes of Xi-RobTME group were compared with a Si-RobTME group selected using a case-matched methodology. Overall operative times and mean hospital stays were shorter in the Xi-RobTME group. Surgeries were fully robotic with a complete take-down of the splenic flexure in all Xi-RobTME cases, while only four cases of the Si-RobTME group were fully robotic, with two cases of complete take-down of the splenic flexure. The new da Vinci Xi could offer some advantages with respect to the da Vinci Si in rectal resection for cancer. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Virtual reality training improves da Vinci performance: a prospective trial.

    PubMed

    Cho, Jae Sung; Hahn, Koo Yong; Kwak, Jung Myun; Kim, Jin; Baek, Se Jin; Shin, Jae Won; Kim, Seon Hahn

    2013-12-01

    The DV-Trainer™ (a virtual reality [VR] simulator) (Mimic Technologies, Inc., Seattle, WA) is one of several different robotic surgical training methods. We designed a prospective study to determine whether VR training could improve da Vinci(®) Surgical System (Intuitive Surgical, Inc., Sunnyvale, CA) performance. Surgeons (n=12) were enrolled using a randomized protocol. Groups 1 (VR training) and 2 (control) participated in VR and da Vinci exercises. Participants' time and moving distance were combined to determine a composite score: VR index=1000/(time×moving distance). The da Vinci exercises included needle control and suturing. Procedure time and error were measured. A composite index (DV index) was computed and used to measure da Vinci competency. After the initial trial with both the VR and da Vinci exercises, only Group 1 was trained with the VR simulator following our institutional curriculum for 3 weeks. All members of both groups then participated in the second trial of the VR and da Vinci exercises and were scored in the same way as in the initial trial. In the initial trial, there was no difference in the VR index (Group 1 versus Group 2, 8.9 ± 3.3 versus 9.4 ± 3.7; P=.832) and the DV index (Group 1 versus Group 2, 3.85 ± 0.73 versus 3.66 ± 0.65; P=.584) scores between the two groups. At the second time point, Group 1 showed increased VR index scores in comparison with Group 2 (19.3 ± 4.5 versus 9.7 ± 4.1, respectively; P=.001) and improved da Vinci performance skills as measured by the DV index (5.80 ± 1.13 versus 4.05 ± 1.03, respectively; P=.028) and by suturing time (7.1 ± 1.54 minutes versus 10.55 ± 1.93 minutes, respectively; P=.018). We found that VR simulator training can improve da Vinci performance. VR practice can result in an early plateau in the learning curve for robotic practice under controlled circumstances.

  16. Multiquadrant robotic colorectal surgery: the da Vinci Xi vs Si comparison.

    PubMed

    Protyniak, Bogdan; Jorden, Jeffrey; Farmer, Russell

    2018-03-01

    The newly introduced da Vinci Xi Surgical System hopes to address the shortcomings of its predecessor, specifically robotic arm restrictions and difficulty working in multiple quadrants. We compare the two robot platforms in multiquadrant surgery at a major colorectal referral center. Forty-four patients in the da Vinci Si group and 26 patients in the Xi group underwent sigmoidectomy or low anterior resection between 2014 and 2016. Patient demographics, operative variables, and postoperative outcomes were compared using descriptive statistics. Both groups were similar in age, sex, BMI, pelvic surgeries, and ASA class. Splenic flexure was mobilized in more (p = 0.045) da Vinci Xi cases compared to da Vinci Si both for sigmoidectomy (50 vs 15.4%) and low anterior resection (60 vs 29%). There was no significant difference in operative time (219.9 vs 224.7 min; p = 0.640), blood loss (170.0 vs 188.1 mL; p = 0.289), length of stay (5.7 vs 6 days; p = 0.851), or overall complications (26.9 vs 22.7%; p = 0.692) between the da Vinci Xi and Si groups, respectively. Single-dock multiquadrant robotic surgery, measured by splenic flexure mobilization with concomitant pelvic dissection, was more frequently performed using the da Vinci Xi platform with no increase in operative time, bleeding, or postoperative complications. The new platform provides surgeons an easier alternative to the da Vinci Si dual docking or combined robotic/laparoscopic multiquadrant surgery.

  17. Load evaluation of the da Vinci surgical system for transoral robotic surgery.

    PubMed

    Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya

    2015-12-01

    Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.

  18. Output control of da Vinci surgical system's surgical graspers.

    PubMed

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Performances on simulator and da Vinci robot on subjects with and without surgical background.

    PubMed

    Moglia, Andrea; Ferrari, Vincenzo; Melfi, Franca; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred; Morelli, Luca

    2017-08-17

    To assess whether previous training in surgery influences performance on da Vinci Skills Simulator and da Vinci robot. In this prospective study, thirty-seven participants (11 medical students, 17 residents, and 9 attending surgeons) without previous experience in laparoscopy and robotic surgery performed 26 exercises at da Vinci Skills Simulator. Thirty-five then executed a suture using a da Vinci robot. The overall scores on the exercises at the da Vinci Skills Simulator show a similar performance among the groups with no statistically significant pair-wise differences (p < .05). The quality of the suturing based on the unedited videos of the test run was similar for the intermediate (7 (4, 10)) and expert group (6.5 (4.5, 10)), and poor for the untrained groups (5 (3.5, 9)), without statistically significant difference (p < .05). This study showed, for subjects new to laparoscopy and robotic surgery, insignificant differences in the scores at the da Vinci Skills Simulator and at the da Vinci robot on inanimate models.

  20. Da Vinci Xi Robot–Assisted Penetrating Keratoplasty

    PubMed Central

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-01-01

    Purpose This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Methods Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Results Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5–61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. Conclusions We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Translational Relevance Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use. PMID:28660096

  1. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    PubMed

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  2. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    PubMed

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  3. Thinking like Leonardo da Vinci and its implications for the modern doctor.

    PubMed

    Baum, Neil

    2013-01-01

    Most people when asked to name the most creative, innovative, and multidimensional people in history would agree that Leonardo da Vinci is either at the top or very close to the number one position on that list. Wouldn't it be nice to think like da Vinci? This article shares the seven unique principles of thinking that da Vinci used that enabled him to be the greatest painter, sculptor, architect, musician, mathematician, engineer, inventor, anatomist, geologist, cartographer, botanist, and writer of his (if not of all) time. This article will take you deep into the notebooks and codices of da Vinci, and suggest ways his ideas can be used by anyone in the healthcare profession to make them a better healthcare provider.

  4. Early clinical experience with the da Vinci Xi Surgical System in general surgery.

    PubMed

    Hagen, Monika E; Jung, Minoa K; Ris, Frederic; Fakhro, Jassim; Buchs, Nicolas C; Buehler, Leo; Morel, Philippe

    2017-09-01

    The da Vinci Xi Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) has been released in 2014 to facilitate minimally invasive surgery. Novel features are targeted towards facilitating complex multi-quadrant procedures, but data is scarce so far. Perioperative data of patients who underwent robotic general surgery with the da Vinci Xi system within the first 6 month after installation were collected and analyzed. The gastric bypass procedures performed with the da Vinci Xi Surgical System were compared to an equal amount of the last procedures with the da Vinci Si Surgical System. Thirty-one foregut (28 Roux-en-Y gastric bypasses), 6 colorectal procedures and 1 revisional biliary procedure were performed. The mean operating room (OR) time was 221.8 (±69.0) minutes for gastric bypasses and 306.5 (±48.8) for colorectal procedures with mean docking time of 9.4 (±3.8) minutes. The gastric bypass procedure was transitioned from a hybrid to a fully robotic approach. In comparison to the last 28 gastric bypass procedures performed with the da Vinci Si Surgical System, the OR time was comparable (226.9 versus 230.6 min, p = 0.8094), but the docking time significantly longer with the da Vinci Xi Surgical System (8.5 versus 6.1 min, p = 0.0415). All colorectal procedures were performed with a single robotic docking. No intraoperative and two postoperative complications occurred. The da Vinci Xi might facilitate single-setups of totally robotic gastric bypass and colorectal surgeries. However, further comparable research is needed to clearly determine the significance of this latest version of the da Vinci Surgical System.

  5. The real code of leonardo da vinci.

    PubMed

    Ose, Leiv

    2008-02-01

    Leonardo da Vinci was born in Italy. Among the researchers and scientists, he is favourably known for his remarkable efforts in scientific work. His investigations of atherosclerosis judiciously combine three separate fields of research. In 1506, he finished his masterpiece, painting of Mona Lisa. A careful clinical examination of the famous painting reveals a yellow irregular leather-like spot at the inner end of the left upper eyelid and a soft bumpy well-defined swelling of the dorsum of the right hand beneath the index finger about 3 cm long. This is probably the first case of familial hypercholesterolemia (FH). The FH code of Leonardo da Vinci was given immense consideration by scientists like Carl Muller, who described the xanthomas tuberosum and angina pectoris. On the contrary, Akira Endo searched for microbial metabolites that would inhibit HMG-CoA reductase, the rate-limiting enzyme in the synthesis of cholesterol and finally, Michael Brown and Joseph Goldstein published a remarkable series of elegant and insightful papers in the 70s and 80s. They established that the cellular uptake of low-density lipoprotein (LDL) essentially requires the LDL receptor. this was the real Code of Leonardo da Vinci.

  6. Leonardo da Vinci's studies of the heart.

    PubMed

    Shoja, Mohammadali M; Agutter, Paul S; Loukas, Marios; Benninger, Brion; Shokouhi, Ghaffar; Namdar, Husain; Ghabili, Kamyar; Khalili, Majid; Tubbs, R Shane

    2013-08-20

    Leonardo da Vinci's detailed drawings are justly celebrated; however, less well known are his accounts of the structures and functions of the organs. In this paper, we focus on his illustrations of the heart, his conjectures about heart and blood vessel function, his experiments on model systems to test those conjectures, and his unprecedented conclusions about the way in which the cardiovascular system operates. In particular, da Vinci seems to have been the first to recognize that the heart is a muscle and that systole is the active phase of the pump. He also seems to have understood the functions of the auricles and pulmonary veins, identified the relationship between the cardiac cycle and the pulse, and explained the hemodynamic mechanism of valve opening and closure. He also described anatomical variations and changes in structure and function that occurred with age. We outline da Vinci's varied career and suggest ways in which his personality, experience, skills and intellectual heritage contributed to these advances in understanding. We also consider his influence on later studies in anatomy and physiology. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Leonardo da Vinci's foot: historical evidence of concept.

    PubMed

    Jastifer, James R; Toledo-Pereyra, Luis H

    2012-10-01

    Leonardo da Vinci (1452-1519), world-renowned Italian renaissance master, is known for his contributions to, and broad interests in science and art. The objective of this work is to demonstrate the extent of his science by applying the use of his concepts to current models of foot and ankle mechanics. The art and science of Leonardo Da Vinci were extensively analyzed by reviewing his original drawings and hand written notebooks as well as their English translation. Current medical journals including the topics of foot, ankle, and biomechanics were reviewed for modern evidence and application of his concepts. The library of Michigan State University and the electronic library of the Royal Library at Windsor Castle were extensively utilized. From the depths of Santa Maria Nuova Hospital in Florence and Santo Spirito Hospital in Rome, through his commentary and anatomical drawings of around 30 cadaver dissections he performed, Leonardo da Vinci expressed his concept of foot and ankle anatomy and mechanics. He laid forth concepts, which vary little from current theories including those of proportion, statics and joint stability, sesamoid biomechanics, and structural support of the foot. Leonardo da Vinci, by combining an interest in anatomy and a gift of genius and artistic ability laid a foundation of foot and ankle anatomy and mechanics that have been applied in modern clinical sciences. Leonardo in this way made important contributions to the practice of foot and ankle orthopedics.

  8. Leonardo Da Vinci and stroke - vegetarian diet as a possible cause.

    PubMed

    Oztürk, Serefnur; Altieri, Marta; Troisi, Pina

    2010-01-01

    Leonardo da Vinci (April 15, 1452 to May 2, 1519) was an Italian Renaissance architect, musician, anatomist, inventor, engineer, sculptor, geometer, and painter. It has been gleaned from the many available historical documents that da Vinci was a vegetarian who respected and loved animals, and that he suffered from right hemiparesis in the last 5 years of his life. A vegetarian diet has both positive and negative influences on the cerebrovascular system. In this report, a possible relation between a vegetarian diet and stroke is discussed from various perspectives as related to Leonardo da Vinci's stroke. Copyright (c) 2010 S. Karger AG, Basel.

  9. Leonardo da Vinci (1452-1519) and his depictions of the human spine.

    PubMed

    Bowen, Garvin; Gonzales, Jocelyn; Iwanaga, Joe; Fisahn, Christian; Loukas, Marios; Oskouian, Rod J; Tubbs, R Shane

    2017-12-01

    Few individuals in history have exerted so great an influence and made such extensive contributions to so many disciplines as Leonardo da Vinci. Da Vinci's inquisitive, experimental mentality led him to many discoveries, such as spinal cord function and the proper anatomy of several organ systems. Respected not only as an artist but also as an anatomist, he made many significant contributions to the field. This article explores da Vinci's drawings, in relation to the anatomy of the human spine.

  10. Early experience using the da Vinci Surgical System for the treatment of mediastinal tumors.

    PubMed

    Kajiwara, Naohiro; Taira, Masahiro; Yoshida, Koichi; Hagiwara, Masaru; Kakihana, Masatoshi; Usuda, Jitsuo; Uchida, Osamu; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2011-10-01

    The da Vinci Surgical System has been used in only a few cases for treating mediastinal tumors in Japan. Recently, we used the da Vinci Surgical System for various types of anterior and middle mediastinal tumors in clinical practice. We report our early experience using the da Vinci Surgical System. Seven patients gave written informed consent to undergo robotic surgery for mediastinal tumor dissection using the da Vinci Surgical System. We evaluated the safety and feasibility of this system for the surgical treatment of mediastinal tumors. Two specialists in thoracic surgery who are certified to use the da Vinci S Surgical System and another specialist acted as an assistant performed the tumor dissection. We were able to access difficult-to-reach areas, such as the mediastinum, safely. All the resected tumors were classified as benign tumors histologically. The average da Vinci setting time was 14.0 min, the average working time was 55.7 min, and the average overall operating time was 125.9 min. The learning curve for the da Vinci setup and manipulation time was short. Robotic surgery enables mediastinal tumor dissection in certain cases more safely and easily than conventional video-assisted thoracoscopic surgery and less invasively than open thoracotomy.

  11. Is da Vinci Xi Better than da Vinci Si in Robotic Rectal Cancer Surgery? Comparison of the 2 Generations of da Vinci Systems.

    PubMed

    Ozben, Volkan; Cengiz, Turgut B; Atasoy, Deniz; Bayraktar, Onur; Aghayeva, Afag; Erguner, Ilknur; Baca, Bilgi; Hamzaoglu, Ismail; Karahasanoglu, Tayfun

    2016-10-01

    We aimed to compare perioperative outcomes for procedures using the latest generation of da Vinci robot versus its previous version in rectal cancer surgery. Fifty-three patients undergoing robotic rectal cancer surgery between January 2010 and March 2015 were included. Patients were classified into 2 groups (Xi, n=28 vs. Si, n=25) and perioperative outcomes were analyzed. The groups had significant differences including operative procedure, hybrid technique and redocking (P>0.05). In univariate analysis, the Xi group had shorter console times (265.7 vs. 317.1 min, P=0.006) and total operative times (321.6 vs. 360.4 min, P=0.04) and higher number of lymph nodes harvested (27.5 vs. 17.0, P=0.008). In multivariate analysis, Xi robot was associated with a shorter console time (odds ratio: 0.09, P=0.004) with no significant differences regarding other outcomes. Both generations of da Vinci robot led to similar short-term outcomes in rectal cancer surgery, but the Xi robot allowed shorter console times.

  12. [The rational application of Da Vinci surgical system in thyroidectomy].

    PubMed

    He, Q Q

    2017-08-01

    Da Vinci surgical system is the most advanced minimally invasive surgical platform in the world, and this system has been widely used in cardiac surgery, urology surgery, gynecologic surgery and general surgery. Although the application of this system was relatively late in thyroid surgery, the number of thyroidectomy with Da Vinci surgical system is increasing quickly. Having reviewed recent studies and summarized clinical experience, compared with traditional open operation, the robotic thyroidectomy has the same surgical safety and effectiveness in selective patients with thyroid cancer. In this paper, several aspects on this novel operation were demonstrated, including surgical indications and contraindications, the approaches, surgical procedures and postoperative complications, in order to promote the rational application of Da Vinci surgical system in thyroidectomy.

  13. The Real Code of Leonardo da Vinci

    PubMed Central

    Ose, Leiv

    2008-01-01

    Leonardo da Vinci was born in Italy. Among the researchers and scientists, he is favourably known for his remarkable efforts in scientific work. His investigations of atherosclerosis judiciously combine three separate fields of research. In 1506, he finished his masterpiece, painting of Mona Lisa. A careful clinical examination of the famous painting reveals a yellow irregular leather-like spot at the inner end of the left upper eyelid and a soft bumpy well-defined swelling of the dorsum of the right hand beneath the index finger about 3 cm long. This is probably the first case of familial hypercholesterolemia (FH). The FH code of Leonardo da Vinci was given immense consideration by scientists like Carl Muller, who described the xanthomas tuberosum and angina pectoris. On the contrary, Akira Endo searched for microbial metabolites that would inhibit HMG-CoA reductase, the rate-limiting enzyme in the synthesis of cholesterol and finally, Michael Brown and Joseph Goldstein published a remarkable series of elegant and insightful papers in the 70s and 80s. They established that the cellular uptake of low-density lipoprotein (LDL) essentially requires the LDL receptor. In conclusion: this was the real Code of Leonardo da Vinci. PMID:19924278

  14. Color constrains depth in da Vinci stereopsis for camouflage but not occlusion.

    PubMed

    Wardle, Susan G; Gillam, Barbara J

    2013-12-01

    Monocular regions that occur with binocular viewing of natural scenes can produce a strong perception of depth--"da Vinci stereopsis." They occur either when part of the background is occluded in one eye, or when a nearer object is camouflaged against a background surface in one eye's view. There has been some controversy over whether da Vinci depth is constrained by geometric or ecological factors. Here we show that the color of the monocular region constrains the depth perceived from camouflage, but not occlusion, as predicted by ecological considerations. Quantitative depth was found in both cases, but for camouflage only when the color of the monocular region matched the binocular background. Unlike previous reports, depth failed even when nonmatching colors satisfied conditions for perceptual transparency. We show that placing a colored line at the boundary between the binocular and monocular regions is sufficient to eliminate depth from camouflage. When both the background and the monocular region contained vertical contours that could be fused, some observers appeared to use fusion, and others da Vinci constraints, supporting the existence of a separate da Vinci mechanism. The results show that da Vinci stereopsis incorporates color constraints and is more complex than previously assumed.

  15. [First experience in the thyroid and parathyroid surgery using the da Vinci® system].

    PubMed

    Al Kadah, B; Siemer, S; Schick, B

    2014-01-01

    Endoscopic surgery for the treatment of thyroid and parathyroid pathologies is gaining increasing attention. The da Vinci® system has been already widely used in different fields of medicine including recently thyroid and parathyroid surgery. Herein we report our first experiences in endoscopic surgery of thyroid and parathyroid pathologies using the da Vinci® system. 8 patients presenting with struma nodosa in 6 cases and parathyroid adenomas in 2 cases have been treated using the da Vinci® system at the ENT department of Homburg/Saar University. The skin incision to introduce the instruments with the da Vinci® system were axilar or at the lateral segment of the clavicle. The neurovascular structures like inferior laryngeal nerve as well as the pathologies were clearly 3-dimensional visualized in all 8 cases. No paralysis of the vocal cord was observed. All patients had in histological examination a benign pathology. The endoscopic surgery of the thyroid and parathyroid gland can be performed using the da Vinci® system and offers an excellent, intraoperative, 3-dimensional visualization of the neurovascular structures. Additionally the da Vinci® system enables skin incisions within considerable distance from the thyroid and parathyroid gland. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Complete daVinci versus laparoscopic pyeloplasty: cost analysis.

    PubMed

    Bhayani, Sam B; Link, Richard E; Varkarakis, John M; Kavoussi, Louis R

    2005-04-01

    Computer-assisted pyeloplasty with the daVinci system is an emerging technique to treat ureteropelvic junction (UPJ) obstruction. A relative cost analysis was performed assessing this technology in comparison with purely laparoscopic pyeloplasty. Eight patients underwent computer-assisted (daVinci) dismembered pyeloplasty (CP) via a transperitoneal four-port approach. They were compared with 13 patients who underwent purely laparoscopic pyeloplasty (LP). All patients had a primary UPJ obstruction and were matched for age, sex, and body mass index. The cost of equipment and capital depreciation for both procedures, as well as assessment of room set-up time, takedown time, and personnel were analyzed. Surgeons and nursing staff for both groups were experienced in both laparoscopy and daVinci procedures. One- and two-way financial analysis was performed to assess relative costs. The mean set-up and takedown time was 71 minutes for CP and 49 minutes for LP. The mean length of stay was 2.3 days for CP and 2.5 days for LP. The mean operating room (OR) times for CP and LP were 176 and 210 minutes, respectively. There were no complications in either group. One-way cost analysis with an economic model showed that LP is more cost effective than CP at our hospital if LP OR time is <338 minutes. With adjustment to a volume of 500 daVinci cases/year, CP is still not as cost effective as LP. Two-way sensitivity analysis shows that in-room time must still be <130 minutes and yearly cases must be >500 to obtain cost equivalence for CP. Perioperative parameters for CP are encouraging. However, the costs are a clear disadvantage. In our hospital, it is more cost effective to teach and perform LP than to perform CP.

  17. [Anesthesia experiences on laparoscopic nephrectomy with da Vinci S robotics].

    PubMed

    Mou, Ling; Lan, Zhixun

    2015-09-01

    To summarize the clinical anesthesia experiences in 20 patients who underwent laparoscopic nephrectomy with da Vinci S robotics.
 Anesthesia data of 20 patients from Sichuan Provincial People's Hospital, who underwent laparoscopic nephrectomy with da Vinci S robotics from August 2014 to November 2014, were analyzed and summarized. The anesthesia time, operation time, CO(2) pneumoperitoneum time, PaCO(2) and PETCO(2) were recorded.
 All patients were anesthetized and underwent surgery with da Vinci S robotics. The anesthesia time was (220±14) min, the operation time was (187±11) min, and the CO(2) pneumoperitoneum time was (180±13) min. The PaCO(2) and PETCO(2) were significantly elevated at 1.5 h after operation compared with those at the baseline (before pneumoperitoneum) (P<0.05). The pH value was significantly decreased at 2.5 h after operation compared to that at the baseline (P<0.05). The peak airway pressure of inspiration was significantly elevated at 0.5 h after the beginning of pneumoperitoneum compared to that at the baseline (P<0.05).
 The hemodynamics is stable during the laparoscopic nephrectomy with da vinci S robotics. However, the duration of CO(2) pneumoperitoneum is significantly increased compared to that of other surgical procedures, resulting in high airway resistance and acid-base disturbance.

  18. A Creative Approach to the Common Core Standards: The Da Vinci Curriculum

    ERIC Educational Resources Information Center

    Chaucer, Harry

    2012-01-01

    "A Creative Approach to the Common Core Standards: The Da Vinci Curriculum" challenges educators to design programs that boldly embrace the Common Core State Standards by imaginatively drawing from the genius of great men and women such as Leonardo da Vinci. A central figure in the High Renaissance, Leonardo made extraordinary contributions as a…

  19. A Value-Engaged Approach for Evaluating the Bunche-Da Vinci Learning Academy

    ERIC Educational Resources Information Center

    Greene, Jennifer C.

    2005-01-01

    In 2001, the Bunche Academy was chosen by its district to join in partnership with the Da Vinci Learning Corporation to embark on an ambitious whole-school reform initiative, especially designed by the corporation for low-performing schools. In this chapter, the author describes how, as illustrated in the Bunche-Da Vinci Learning Academy context,…

  20. The da Vinci robotic surgical assisted anterior lumbar interbody fusion: technical development and case report.

    PubMed

    Beutler, William J; Peppelman, Walter C; DiMarco, Luciano A

    2013-02-15

    Technique development to use the da Vince Robotic Surgical System for anterior lumbar interbody fusion at L5-S1 is detailed. A case report is also presented. To evaluate and develop the da Vinci robotic assisted laparoscopic anterior lumbar stand-alone interbody fusion procedure. Anterior lumbar interbody fusion is a common procedure associated with potential morbidity related to the surgical approach. The da Vinci robot provides intra-abdominal dissection and visualization advantages compared with the traditional open and laparoscopic approach. The surgical techniques for approach to the anterior lumbar spine using the da Vinci robot were developed and modified progressively beginning with operative models followed by placement of an interbody fusion cage in the living porcine model. Development continued to progress with placement of fusion cage in a human cadaver, completed first in the laboratory setting and then in the operating room. Finally, the first patient with fusion completed using the da Vinci robot-assisted approach is presented. The anterior transperitoneal approach to the lumbar spine is accomplished with enhanced visualization and dissection capability, with maintenance of pneumoperitoneum using the da Vinci robot. Blood loss is minimal. The visualization inside the disc space and surrounding structures was considered better than current open and laparoscopic techniques. The da Vinci robot Surgical System technique continues to develop and is now described for the transperitoneal approach to the anterior lumbar spine. 4.

  1. SAGES TAVAC safety and effectiveness analysis: da Vinci ® Surgical System (Intuitive Surgical, Sunnyvale, CA).

    PubMed

    Tsuda, Shawn; Oleynikov, Dmitry; Gould, Jon; Azagury, Dan; Sandler, Bryan; Hutter, Matthew; Ross, Sharona; Haas, Eric; Brody, Fred; Satava, Richard

    2015-10-01

    The da Vinci(®) Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) is a computer-assisted (robotic) surgical system designed to enable and enhance minimally invasive surgery. The Food and Drug Administration (FDA) has cleared computer-assisted surgical systems for use by trained physicians in an operating room environment for laparoscopic surgical procedures in general, cardiac, colorectal, gynecologic, head and neck, thoracic and urologic surgical procedures. There are substantial numbers of peer-reviewed papers regarding the da Vinci(®) Surgical System, and a thoughtful assessment of evidence framed by clinical opinion is warranted. The SAGES da Vinci(®) TAVAC sub-committee performed a literature review of the da Vinci(®) Surgical System regarding gastrointestinal surgery. Conclusions by the sub-committee were vetted by the SAGES TAVAC Committee and SAGES Executive Board. Following revisions, the document was evaluated by the TAVAC Committee and Executive Board again for final approval. Several conclusions were drawn based on expert opinion organized by safety, efficacy, and cost for robotic foregut, bariatric, hepatobiliary/pancreatic, colorectal surgery, and single-incision cholecystectomy. Gastrointestinal surgery with the da Vinci(®) Surgical System is safe and comparable, but not superior to standard laparoscopic approaches. Although clinically acceptable, its use may be costly for select gastrointestinal procedures. Current data are limited to the da Vinci(®) Surgical System; further analyses are needed.

  2. Solving da Vinci stereopsis with depth-edge-selective V2 cells

    PubMed Central

    Assee, Andrew; Qian, Ning

    2007-01-01

    We propose a new model for da Vinci stereopsis based on a coarse-to-fine disparity-energy computation in V1 and disparity-boundary-selective units in V2. Unlike previous work, our model contains only binocular cells, relies on distributed representations of disparity, and has a simple V1-to-V2 feedforward structure. We demonstrate with random dot stereograms that the V2 stage of our model is able to determine the location and the eye-of-origin of monocularly occluded regions and improve disparity map computation. We also examine a few related issues. First, we argue that since monocular regions are binocularly defined, they cannot generally be detected by monocular cells. Second, we show that our coarse-to-fine V1 model for conventional stereopsis explains double matching in Panum’s limiting case. This provides computational support to the notion that the perceived depth of a monocular bar next to a binocular rectangle may not be da Vinci stereopsis per se (Gillam et al., 2003). Third, we demonstrate that some stimuli previously deemed invalid have simple, valid geometric interpretations. Our work suggests that studies of da Vinci stereopsis should focus on stimuli more general than the bar-and-rectangle type and that disparity-boundary-selective V2 cells may provide a simple physiological mechanism for da Vinci stereopsis. PMID:17698163

  3. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    PubMed

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  4. The da Vinci telerobotic surgical system: the virtual operative field and telepresence surgery.

    PubMed

    Ballantyne, Garth H; Moll, Fred

    2003-12-01

    The United States Department of Defense developed the telepresence surgery concept to meet battlefield demands. The da Vinci telerobotic surgery system evolved from these efforts. In this article, the authors describe the components of the da Vinci system and explain how the surgeon sits at a computer console, views a three-dimensional virtual operative field, and performs the operation by controlling robotic arms that hold the stereoscopic video telescope and surgical instruments that simulate hand motions with seven degrees of freedom. The three-dimensional imaging and handlike motions of the system facilitate advanced minimally invasive thoracic, cardiac, and abdominal procedures. da Vinci has recently released a second generation of telerobots with four arms and will continue to meet the evolving challenges of surgery.

  5. Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?

    PubMed

    Patel, Manish N; Aboumohamed, Ahmed; Hemal, Ashok

    2015-12-01

    To describe our robot-assisted nephroureterectomy (RNU) technique for benign indications and RNU with en bloc excision of bladder cuff (BCE) and lymphadenectomy (LND) for malignant indications using the da Vinci Si and da Vinci Xi robotic platform, with its pros and cons. The port placement described for Si can be used for standard and S robotic systems. This is the first report in the literature on the use of the da Vinci Xi robotic platform for RNU. After a substantial experience of RNU using different da Vinci robots from the standard to the Si platform in a single-docking fashion for benign and malignant conditions, we started using the newly released da Vinci Xi robot since 2014. The most important differences are in port placement and effective use of the features of da Vinci Xi robot while performing simultaneous upper and lower tract surgery. Patient positioning, port placement, step-by-step technique of single docking RNU-LND-BCE using the da Vinci Si and da Vinci Xi robot are shown in an accompanying video with the goal that centres using either robotic system benefit from the hints and tips. The first segment of video describes RNU-LND-BCE using the da Vinci Si followed by the da Vinci Xi to highlight differences. There was no need for patient repositioning or robot re-docking with the new da Vinci Xi robotic platform. We have experience of using different robotic systems for single docking RNU in 70 cases for benign (15) and malignant (55) conditions. The da Vinci Xi robotic platform helps operating room personnel in its easy movement, allows easier patient side-docking with the help of its boom feature, in addition to easy and swift movements of the robotic arms. The patient clearance feature can be used to avoid collision with the robotic arms or the patient's body. In patients with challenging body habitus and in situations where bladder cuff management is difficult, modifications can be made through reassigning the camera to a different port with

  6. Hidden sketches by Leonardo da Vinci revealed

    NASA Astrophysics Data System (ADS)

    Dumé, Belle

    2009-02-01

    Three drawings on the back of Leonardo da Vinci's The Virgin and Child with St Anne (circa 1508) have been discovered by researchers led by Michel Menu from the Centre de Recherche et de Restauration des Musées de France (C2RMF) and the Louvre Museum in Paris.

  7. Aerodynamic design of the Cal Poly Da Vinci Human-Powered Helicopter

    NASA Technical Reports Server (NTRS)

    Larwood, Scott; Saiki, Neal

    1990-01-01

    This paper will discuss the methodology used in designing the rotor and drive propellers for the third generation Cal Poly Da Vinci Human-Powered Helicopter. The rotor was designed using a lifting surface, uniform inflow hover analysis code and the propeller was designed using a minimum induced-loss method. Construction, geometry, and operating considerations are discussed as they impact the designs. Optimization of the design performance is also explained. The propellers were tested in a wind tunnel and results are compared with theoretical data. Successful flight tests of the Da Vinci III are discussed.

  8. [Leonardo da Vinci--a dyslectic genius?].

    PubMed

    Røsstad, Anna

    2002-12-10

    Leonardo da Vinci's texts consist almost exclusively of scientific notes. Working on a book on Leonardo's art, I studied all Leonardo's published texts carefully for any new information. In some prefaces I came to suspect that Leonardo might have suffered from dyslexia. This article considers the question of whether it is possible to find indications of dyslexia in Leonardo's texts and in the accounts of his life.

  9. A Proposal to Build Evaluation Capacity at the Bunche-Da Vinci Learning Partnership Academy

    ERIC Educational Resources Information Center

    King, Jean A.

    2005-01-01

    The author describes potential evaluation capacity-building activities in contrast to the specifics of an evaluation design. Her response to the case of the Bunche-Da Vinci Learning Partnership Academy is developed in three parts: (1) an initial framing of the Bunche-Da Vinci situation; (2) what should be done before signing a contract; and (3)…

  10. Robotic resections in hepatobiliary oncology - initial experience with Xi da Vinci system in India.

    PubMed

    Chandarana, M; Patkar, S; Tamhankar, A; Garg, S; Bhandare, M; Goel, M

    2017-01-01

    Minimal invasive surgery has proven its advantages over open surgeries in the perioperative period. Food and Drug Administration approved da Vinci robot in 2000. The latest version, da Vinci Xi system has a mobile tower-based robot with several modifications to improve the functionality, versatility, and operative ease. None of the centers have reported exclusively on hepatobiliary oncology using the da Vinci Xi system. We report our initial experience. To study the feasibility, advantages, and discuss the operative technique of da Vinci Xi system in hepatobiliary oncology. Data were analyzed retrospectively from a prospectively maintained database from June 2015 to October 2016. Twenty-five patients with suspected or proven hepatobiliary malignancies were operated. Total robotic technique using da Vinci Xi system was used. Demographic details and perioperative outcomes were noted. Of the 25 surgeries, 14 patients had a suspected gallbladder malignancy, 11 patients had primary or metastatic liver tumor. Median age was 53 years. The average duration of surgery was 225 min with a median blood loss 150 ml. The median postoperative stay was 4 days. The median nodal yield for radical cholecystectomy was seven. Five patients required conversion. Two of these developed postoperative morbidity. Robotic surgery for hepatobiliary oncology is feasible and can be performed safely in experienced hands. Increasing experience in this field may equal or even prove advantageous over conventional or laparoscopic approach in future. A cautious approach with judicious patient selection is the key to establishing robotic surgery as a standard surgical approach.

  11. DaVinci's Mona Lisa entering the next dimension.

    PubMed

    Carbon, Claus-Christian; Hesslinger, Vera M

    2013-01-01

    For several of Leonardo da Vinci's paintings, such as The Virgin and Child with St Anne or the Mona Lisa, there exist copies produced by his own studio. In case of the Mona Lisa, a quite exceptional, rediscovered studio copy was presented to the public in 2012 by the Prado Museum in Madrid. Not only does it mirror its famous counterpart superficially; it also features the very same corrections to the lower layers, which indicates that da Vinci and the 'copyist' must have elaborated their panels simultaneously. On the basis of subjective (thirty-two participants estimated painter-model constellations) as well as objective data (analysis of trajectories between landmarks of both paintings), we revealed that both versions differ slightly in perspective. We reconstructed the original studio setting and found evidence that the disparity between both paintings mimics human binocular disparity. This points to the possibility that the two Giocondas together might represent the first stereoscopic image in world history.

  12. Battle of the bots: a comparison of the standard da Vinci and the da Vinci Surgical Skills Simulator in surgical skills acquisition.

    PubMed

    Brown, Kevin; Mosley, Natalie; Tierney, James

    2017-06-01

    Virtual reality simulators are increasingly used to gain robotic surgical skills. This study compared use of the da Vinci Surgical Skills Simulator (dVSSS) to the standard da Vinci (SdV) robot for skills acquisition in a prospective randomized study. Residents from urology, gynecology, and general surgery programs performed three virtual reality tasks (thread the ring, ring rail, and tubes) on the dvSSS. Participants were then randomized to one of the two study groups (dVSSS and SdV). Each participant then practiced on either the dVSSS or the SdV (depending on randomization) for 30 min per week over a 4-week time period. The dVSSS arm was not permitted to practice ring rail (due to no similar practice scenario available for the SdV group). Following 4 weeks of practice, participants performed the same three virtual reality tasks and the results were recorded and compared to baseline. Overall and percent improvement were recorded for all participants from pre-test to post-test. Two-way ANOVA analyses were used to compare the dVSSS and SdV groups and three tasks. Initially, 30 participants were identified and enrolled in the study. Randomization resulted in 15 participants in each arm. During the course of the study, four participants were unable to complete all tasks and practice sessions and were, therefore, excluded. This resulted in a total of 26 participants (15 in the dVSSS group and 11 in the SdV group) who completed the study. Overall total improvement score was found to be 23.23 and 23.48 for the SdV and dVSSS groups, respectively (p = 0.9245). The percent improvement was 60 and 47 % for the SdV and dVSSS groups respectively, which was a statistically significant difference between the two groups and three tasks. Practicing on the standard da Vinci is comparable to practicing on the da Vinci simulator for acquiring robotic surgical skills. In spite of several potential advantages, the dVSSS arm performed no better than the SdV arm in the final

  13. Modifications of transaxillary approach in endoscopic da Vinci-assisted thyroid and parathyroid gland surgery.

    PubMed

    Al Kadah, Basel; Piccoli, Micaela; Mullineris, Barbara; Colli, Giovanni; Janssen, Martin; Siemer, Stephan; Schick, Bernhard

    2015-03-01

    Endoscopic surgery for treatment of thyroid and parathyroid pathologies is increasingly gaining attention. The da Vinci system has already been widely used in different fields of medicine and quite recently in thyroid and parathyroid surgery. Herein, we report about modifications of the transaxillary approach in endoscopic surgery of thyroid and parathyroid gland pathologies using the da Vinci system. 16 patients suffering from struma nodosa in 14 cases and parathyroid adenomas in two cases were treated using the da Vinci system at the ENT Department of Homburg/Saar University and in cooperation with the Department of General Surgery in New Sant'Agostino Hospital, Modena/Italy. Two different retractors, endoscopic preparation of the access and three different incision modalities were used. The endoscopic preparation of the access allowed us to have a better view during preparation and reduced surgical time compared to the use of a headlamp. To introduce the da Vinci instruments at the end of the access preparation, the skin incisions were over the axilla with one incision in eight patients, two incisions in four patients and three incisions in a further four patients. The two and three skin incisions modality allowed introduction of the da Vinci instruments without arm conflicts. The use of a new retractor (Modena retractor) compared to a self-developed retractor made it easier during the endoscopic preparation of the access and the reposition of the retractor. The scar was hidden in the axilla and independent of the incisions selected, the cosmetic findings were judged by the patients to be excellent. The neurovascular structures such as inferior laryngeal nerve, superior laryngeal nerve and vessels, as well as the different pathologies, were clearly 3D visualized in all 16 cases. No paralysis of the vocal cord was observed. All patients had a benign pathology in their histological examination. The endoscopic surgery of the thyroid and parathyroid gland can be

  14. How to Think Like Leonardo da Vinci

    ERIC Educational Resources Information Center

    Caouette, Ralph

    2008-01-01

    To be effective and relevant in twenty-first-century learning, art needs to be more inclusive. In this article, the author discusses how teachers can find a good example in Leonardo da Vinci for building an art program. His art, design, and curiosity are the perfect foundation for any art program, at any level. (Contains 3 resources and 3 online…

  15. The influence of ancient Greek thought on fifteenth century anatomy: Galenic influence and Leonardo da Vinci.

    PubMed

    Tubbs, Richard Isaiah; Gonzales, Jocelyn; Iwanaga, Joe; Loukas, Marios; Oskouian, Rod J; Tubbs, R Shane

    2018-06-01

    Leonardo da Vinci (1452-1519) can be called one of the earliest contributors to the history of anatomy and, by extension, the study of medicine. He may have even overshadowed Andreas Vesalius (1514-1564), the so-called founder of human anatomy, if his works had been published within his lifetime. While some of the best illustrations of their time, with our modern knowledge of anatomy, it is clear that many of da Vinci's depictions of human anatomy are inaccurate. However, he also made significant discoveries in anatomy and remarkable predictions of facts he could not yet discover with the technology available to him. Additionally, da Vinci was largely influenced by Greek anatomists, as indicated from his ideas about anatomical structure. In this historical review, we describe da Vinci's history, influences, and discoveries in anatomical research and his depictions and errors with regards to the musculoskeletal system, cardiovascular system, nervous system, and other organs.

  16. Evolution of robots throughout history from Hephaestus to Da Vinci Robot.

    PubMed

    Iavazzo, Christos; Gkegke, Xanthi-Ekaterini D; Iavazzo, Paraskevi-Evangelia; Gkegkes, Ioannis D

    2014-01-01

    Da Vinci robot is increasingly used for operations adding the advantages of robots to the favor of medicine. This is a historical article with the aim to present the evolution of robots in the medical area from the time of ancient myths to Renaissance and finally to the current revolutionary applications. We endeavored to collect several elegant narratives on the topic. The use of imagination could help the reader to find similarities. A trip from the Greek myths of Hephaestus through Aristotle and Leonardo Da Vinci to the robots of Karel Capek and Isaac Asimov and finally the invention of the medical robots is presented.

  17. Thorascopic resection of an apical paraspinal schwannoma using the da Vinci surgical system.

    PubMed

    Finley, David; Sherman, Jonathan H; Avila, Edward; Bilsky, Mark

    2014-01-01

    Posterior mediastinal neurogenic tumors have traditionally been resected via an open posterolateral thoracotomy. Video-assisted thorascopic surgery has emerged as an alternative technique allowing for improved morbidity with decreased blood loss, less postoperative pain, and a shorter recovery period, among others. The da Vinci surgical system, as first described for urologic procedures, has recently been reported for lung lobectomy. This technique provides the advantages of instrumentation with 6 degrees of freedom, stable operating arms, and improved visualization with the three-dimensional high-definition camera. We describe the technique for thorascopic resection of an apical paraspinal schwannoma of the T1 nerve root with the da Vinci surgical system. This technique used a specialized intraoperative neuromonitoring probe for free-running electromyography (EMG) and triggered EMG. We demonstrate successful resection of a posterior paraspinal schwannoma with the da Vinci surgical system while preserving neurologic function. The patient displayed stable intraoperative monitoring of the T1 nerve root and full intrinsic hand strength postoperatively. The technique described in this article introduces robotic system accuracy and precludes the need for an open thoracotomy. In addition, this approach demonstrates the ability of the da Vinci surgical system to safely dissect tumors from their neural attachments and is applicable to other such lesions of similar size and location. Georg Thieme Verlag KG Stuttgart · New York.

  18. Da Vinci robot-assisted anatomic left hemihepatectomy and biliary reconstruction.

    PubMed

    Wang, Zhifei; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Zhou, Ningxin

    2013-06-01

    Since the introduction of Da Vinci robotic surgery, more and more complicated surgeries can now be performed robotically, yet there have been very few on robotic hepatectomy, especially when billiary reconstruction is involved. The video shows our initial experience with an anatomic hepatectomy using Da Vinci surgical robot. In this case, we also conducted billiary reconstruction due to the anatomic abnormality of bile duct, while applying the choledochoscopy. The preoperative diagnosis is primary liver carcinoma, tumor thrombi in bile duct, and hepatitis B. First, the gallbladder was resected, and cystic artery and duct were identified. After opening of the common bile duct above the junction, the choledochoscopy was performed. Tumor thrombi were found in common bile duct and left hepatic duct, and they were all removed. Left branches hepatic artery and portal vein were dissected, ligated, and divided. Thrombi in the left hepatic duct were removed also. After marking the cutting line along the ischemic boarder, liver parenchyma was transected using robotic harmonic scalpel. Branches of ducts were encountered and managed by either direct coagulating or dividing after clipping. The left hepatic vein was visualized, exposed, and divided during hepatectomy. Two T tubes were placed into common hepatic duct and the proximal cutting end of right anterior bile duct which was found to join the left hepatic duct, respectively. The operation went on successfully. The operation time was 410 minutes, the blood loss was 200 mL. The pathologic diagnosis was introductal papillary adenocarcinoma of left hepatic duct. The patient went on well postoperatively and was followed up for 22 months till now. Postoperative computed tomography examination showed no recurrence. Da Vinci-assisted robotic hepatectomy can be performed safely in the hands of experienced hepatobilliary surgeons, and choledochoscopy can be combined for bile duct exploration. With the advantages of Da Vinci robot

  19. The Settings, Pros and Cons of the New Surgical Robot da Vinci Xi System for Transoral Robotic Surgery (TORS): A Comparison With the Popular da Vinci Si System.

    PubMed

    Kim, Da Hee; Kim, Hwan; Kwak, Sanghyun; Baek, Kwangha; Na, Gina; Kim, Ji Hoon; Kim, Se Heon

    2016-10-01

    The da Vinci system (da Vinci Surgical System; Intuitive Surgical Inc.) has rapidly developed in several years from the S system to the Si system and now the Xi System. To investigate the surgical feasibility and to provide workflow guidance for the newly released system, we used the new da Vinci Xi system for transoral robotic surgery (TORS) on a cadaveric specimen. Bilateral supraglottic partial laryngectomy, hypopharyngectomy, lateral oropharyngectomy, and base of the tongue resection were serially performed in search of the optimal procedures with the new system. The new surgical robotic system has been upgraded in all respects. The telescope and camera were incorporated into one system, with a digital end-mounted camera. Overhead boom rotation allows multiquadrant access without axis limitation, the arms are now thinner and longer with grabbing movements for easy adjustments. The patient clearance button dramatically reduces external collisions. The new surgical robotic system has been optimized for improved anatomic access, with better-equipped appurtenances. This cadaveric study of TORS offers guidance on the best protocol for surgical workflow with the new Xi system leading to improvements in the functional results of TORS.

  20. Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using da Vinci Xi.

    PubMed

    Darwiche, Fadi; Swain, Sanjaya; Kallingal, George; Punnen, Sanoj; Manoharan, Murugesan; Parekh, Dipen J; Gonzalgo, Mark L

    2015-01-01

    Robotic-assisted laparoscopic nephroureterectomy (RALNU) has been previously utilized for management of upper tract urothelial carcinoma. The da Vinci Xi surgical system was released in April of 2014. We describe our operative technique and early experience for RALNU using the da Vinci Xi system highlighting unique features of this surgical platform. A total of 10 patients with a diagnosis of upper tract urothelial carcinoma underwent RALNU using the da Vinci Xi system between April and November of 2014. A novel, oblique "in line" robotic trocar configuration was utilized to access the upper abdomen (nephrectomy portion) and pelvis (bladder cuff excision) without undocking. The port hopping feature of da Vinci Xi was utilized to facilitate optimal, multi-quadrant visualization during RALNU. Robotic-assisted laparoscopic nephroureterectomy was successfully completed without open conversion in all 10 patients. Mean operative time was 184 min (range 140-300 min), mean estimated blood loss was 121 cc (range 60-300 cc), and mean hospital stay was 2.4 days. Final pathology demonstrated high grade urothelial carcinoma in all patients. Surgical margins were negative in all patients. No intra-operative complications were encountered. One patient developed a pulmonary embolus after being discharged. No patients required a blood transfusion. Mean patient follow-up was 130 days (range 15-210 days). The use of da Vinci Xi with a novel, oblique "in line" port configuration and camera port hopping technique allows for an efficient and reproducible method for RALNU without the need for repositioning the patient or the robot during surgery.

  1. The Potential da Vinci in All of Us

    ERIC Educational Resources Information Center

    Petto, Sarah; Petto, Andrew

    2009-01-01

    The study of the human form is fundamental to both science and art curricula. For vertebrates, perhaps no feature is more important than the skeleton to determine observable form and function. As Leonard da Vinci's famous Proportions of the Human Figure (Virtruvian Man) illustrates, the size, shape, and proportions of the human body are defined by…

  2. Transoral robotic surgery for the base of tongue squamous cell carcinoma: a preliminary comparison between da Vinci Xi and Si.

    PubMed

    Alessandrini, Marco; Pavone, Isabella; Micarelli, Alessandro; Caporale, Claudio

    2017-09-13

    Considering the emerging advantages related to da Vinci Xi robotic platform, the aim of this study is to compare for the first time the operative outcomes of this tool to the previous da Vinci Si during transoral robotic surgery (TORS), both performed for squamous cell carcinomas (SCC) of the base of tongue (BOT). Intra- and peri-operative outcomes of eight patients with early stage (T1-T2) of the BOT carcinoma and undergoing TORS by means of the da Vinci Xi robotic platform (Xi-TORS) are compared with the da Vinci Si group ones (Si-TORS). With respect to Si-TORS group, Xi-TORS group demonstrated a significantly shorter overall operative time, console time, and intraoperative blood loss, as well as peri-operative pain intensity and length of mean hospital stays and nasogastric tube positioning. Considering recent advantages offered by surgical robotic techniques, the da Vinci Xi Surgical System preliminary outcomes could suggest its possible future routine implementation in BOT squamous cell carcinoma procedures.

  3. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    PubMed

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  4. Training and Health. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document profiles programs in the fields of health and medicine that are offered through the European Commission's Leonardo da Vinci program. The following programs are profiled: (1) CYTOTRAIN (a transnational vocational training program in cervical cancer screening); (2) Apollo (a program of open and distance learning for paramedical…

  5. [History of robotics: from archytas of tarentum until Da Vinci robot. (Part II)].

    PubMed

    Sánchez-Martín, F M; Jiménez Schlegl, P; Millán Rodríguez, F; Salvador-Bayarri, J; Monllau Font, V; Palou Redorta, J; Villavicencio Mavrich, H

    2007-03-01

    Robotic surgery is a reality. In order to to understand how new robots work is interesting to know the history of ancient (see part i) and modern robotics. The desire to design automatic machines imitating humans continued for more than 4000 years. Archytas of Tarentum (at around 400 a.C.), Heron of Alexandria, Hsieh-Fec, Al-Jazari, Bacon, Turriano, Leonardo da Vinci, Vaucanson o von Kempelen were robot inventors. At 1942 Asimov published the three robotics laws. Mechanics, electronics and informatics advances at XXth century developed robots to be able to do very complex self governing works. At 1985 the robot PUMA 560 was employed to introduce a needle inside the brain. Later on, they were designed surgical robots like World First, Robodoc, Gaspar o Acrobot, Zeus, AESOP, Probot o PAKI-RCP. At 2000 the FDA approved the da Vinci Surgical System (Intuitive Surgical Inc, Sunnyvale, CA, USA), a very sophisticated robot to assist surgeons. Currently urological procedures like prostatectomy, cystectomy and nephrectomy are performed with the da Vinci, so urology has become a very suitable speciality to robotic surgery.

  6. Robotic right colectomy using the Da Vinci Single-Site® platform: case report.

    PubMed

    Morelli, Luca; Guadagni, Simone; Caprili, Giovanni; Di Candio, Giulio; Boggi, Ugo; Mosca, Franco

    2013-09-01

    While single-port laparoscopy for abdominal surgery is technically challenging, the Da Vinci Single-Site® robotic surgery platform may help to overcome some of the difficulties of this rapidly evolving technique. The authors of this article present a case of single-incision, robotic right colectomy using this device. A 74-year-old female with malignant polyp of caecum was operated on with a single-site approach using the Da Vinci Single-Site® robotic surgery device. Resection and anastomosis were performed extra-corporeally after undocking the robot. The procedure was successfully completed in 200 min. No surgical complications occurred during the intervention and the post-operative stay and no conversion to laparotomy or additional trocars were required. To the best of our knowledge, this is the first case of right colectomy using the Da Vinci Single-Site® robotic surgery platform to be reported. The procedure is feasible and safe and its main advantages are restoration of triangulation and reduced instrument clashes. Copyright © 2013 John Wiley & Sons, Ltd.

  7. On the Da Vinci size effect in tensile strengths of nanowires: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Zhao, Ziyu; Liu, Jinxing; Soh, Ai Kah

    2018-01-01

    In recent decades, size effects caused by grain size, strain gradient, typical defects etc., have been widely investigated. Nevertheless, the dependence of tensile strength on the specimen length, addressed by Da Vinci around 500 hundred years ago, has received rather limited attention, even though it is one unavoidable question to answer if people attempt to bring materials' amazing nano-scale strengths up to macro-level. Therefore, we make efforts to study tensile behaviors of copper nanowires with a common cross-section and various lengths by employing the molecular dynamics simulations. Surprisingly, a strong size effect of Da Vinci type indeed arises. We have shown the influences of lattice orientation, temperature and prescribed notch on such a Da Vinci size effect. Two different theoretical explanations are briefly proposed for a qualitative understanding. Finally, a simple scaling rule is summarized to cover the tendencies observed.

  8. The DaVinci Project: Multimedia in Art and Chemistry.

    ERIC Educational Resources Information Center

    Simonson, Michael; Schlosser, Charles

    1998-01-01

    Provides an overview of the DaVinci Project, a collaboration of students, teachers, and researchers in chemistry and art to develop multimedia materials for grades 3-12 visualizing basic concepts in chemistry and visual art. Topics addressed include standards in art and science; the conceptual framework for the project; and project goals,…

  9. Automated Support for da Vinci Surgical System

    DTIC Science & Technology

    2011-05-01

    MScore, which provides objective assessment measuring robotic surgery skills across all computed metrics (Figure 7). In addition to viewing single ...holding an object. Data Collection & Analysis (Task 5)  Preliminary Experiments  During the first phase of data collection, a single performance of...a single task (anastomosis) trial was recorded from six different users – three each for the da Vinci and the dV-Trainer platforms. On each platform

  10. [Short-term efficacy of da Vinci robotic surgical system on rectal cancer in 101 patients].

    PubMed

    Zeng, Dong-Zhu; Shi, Yan; Lei, Xiao; Tang, Bo; Hao, Ying-Xue; Luo, Hua-Xing; Lan, Yuan-Zhi; Yu, Pei-Wu

    2013-05-01

    To investigate the feasibility and safety of da Vinci robotic surgical system in rectal cancer radical operation, and to summarize its short-term efficacy and clinical experience. Data of 101 cases undergoing da Vinci robotic surgical system for rectal cancer radical operation from March 2010 to September 2012 were retrospectively analyzed. Evaluation was focused on operative procedure, complication, recovery and pathology. All the 101 cases underwent operation successfully and safely without conversion to open procedure. Rectal cancer radical operation with da Vinci robotic surgical system included 73 low anterior resections and 28 abdominoperineal resections. The average operative time was (210.3±47.2) min. The average blood lose was (60.5±28.7) ml without transfusion. Lymphadenectomy harvest was 17.3±5.4. Passage of first flatus was (2.7±0.7) d. Distal margin was (5.3±2.3) cm without residual cancer cells. The complication rate was 6.9%, including anastomotic leakage(n=2), perineum incision infection(n=2), pulmonary infection (n=2), urinary retention (n=1). There was no postoperative death. The mean follow-up time was(12.9±8.0) months. No local recurrence was found except 2 cases with distant metastasis. Application of da Vinci robotic surgical system in rectal cancer radical operation is safe and patients recover quickly The short-term efficacy is satisfactory.

  11. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    PubMed

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  12. Women and Technical Professions. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document profiles programs for women in technical professions that are offered through the European Commission's Leonardo da Vinci program. The following programs are profiled: (1) Artemis and Diana (vocational guidance programs to help direct girls toward technology-related careers); (2) CEEWIT (an Internet-based information and…

  13. Comparison of standard laparoscopic distal pancreatectomy with minimally invasive distal pancreatectomy using the da Vinci S system.

    PubMed

    Ito, Masahiro; Asano, Yukio; Shimizu, Tomohiro; Uyama, Ichiro; Horiguchi, Akihiko

    2014-01-01

    Minimally invasive procedures for pancreatic pathologies are increasingly being used, including distal pancreatectomy. This study aimed to assess the indications for and outcomes of the da Vinci distal pancreatectomy procedure. We reviewed the medical records of patients who underwent pancreatic head resection from April 2009 to September 2013. Four patients (mean age, 52.7 years) underwent da Vinci distal pancreatectomy and 10 (mean age, 68.0 +/- 12.1 years) underwent laparoscopic distal pancreatectomy. The mean surgical duration was 292 +/- 153 min and 306 +/- 29 min, the mean blood loss was 153 +/- 71 mL and 61.7 +/- 72 mL, and the mean postoperative length of stay was 24 +/- 11 days and 14 +/- 3 days in the da Vinci distal pancreatectomy and laparoscopic distal pancreatectomy groups, respectively. One patient who underwent da Vinci distal pancreatectomy developed a pancreatic fistula, while 2 patients in the laparoscopic distal pancreatectomy group developed splenic ischemia and gastric torsion, respectively. Laparoscopic and robotic pancreatic resection were both safe and feasible in selected patients with distal pancreatic pathologies. Further studies are necessary to clarify the role of robotic surgery in the advanced laparoscopic era.

  14. Visual degradation in Leonardo da Vinci's iconic self-portrait: A nanoscale study

    NASA Astrophysics Data System (ADS)

    Conte, A. Mosca; Pulci, O.; Misiti, M. C.; Lojewska, J.; Teodonio, L.; Violante, C.; Missori, M.

    2014-06-01

    The discoloration of ancient paper, due to the development of oxidized groups acting as chromophores in its chief component, cellulose, is responsible for severe visual degradation in ancient artifacts. By adopting a non-destructive approach based on the combination of optical reflectance measurements and time-dependent density functional theory ab-initio calculations, we describe and quantify the chromophores affecting Leonardo da Vinci's iconic self-portrait. Their relative concentrations are very similar to those measured in modern and ancient samples aged in humid environments. This analysis quantifies the present level of optical degradation of the Leonardo da Vinci's self-portrait which, compared with future measurements, will assess its degradation rate. This is a fundamental information in order to plan appropriate conservation strategies.

  15. Precision in robotic rectal surgery using the da Vinci Xi system and integrated table motion, a technical note.

    PubMed

    Panteleimonitis, Sofoklis; Harper, Mick; Hall, Stuart; Figueiredo, Nuno; Qureshi, Tahseen; Parvaiz, Amjad

    2017-09-15

    Robotic rectal surgery is becoming increasingly more popular among colorectal surgeons. However, time spent on robotic platform docking, arm clashing and undocking of the platform during the procedure are factors that surgeons often find cumbersome and time consuming. The newest surgical platform, the da Vinci Xi, coupled with integrated table motion can help to overcome these problems. This technical note aims to describe a standardised operative technique of single docking robotic rectal surgery using the da Vinci Xi system and integrated table motion. A stepwise approach of the da Vinci docking process and surgical technique is described accompanied by an intra-operative video that demonstrates this technique. We also present data collected from a prospectively maintained database. 33 consecutive rectal cancer patients (24 male, 9 female) received robotic rectal surgery with the da Vinci Xi during the preparation of this technical note. 29 (88%) patients had anterior resections, and four (12%) had abdominoperineal excisions. There were no conversions, no anastomotic leaks and no mortality. Median operation time was 331 (249-372) min, blood loss 20 (20-45) mls and length of stay 6.5 (4-8) days. 30-day readmission rate and re-operation rates were 3% (n = 1). This standardised technique of single docking robotic rectal surgery with the da Vinci Xi is safe, feasible and reproducible. The technological advances of the new robotic system facilitate the totally robotic single docking approach.

  16. Studying and Working Abroad. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document profiles recent successful examples of students studying and working abroad as part of the European Commission's Leonardo da Vinci program, which is designed to give students across the European Union the opportunity to experience vocational training in a foreign country. The following examples are presented: (1) 3 Finnish students…

  17. The First Korean Experience of Telemanipulative Robot-Assisted Laparoscopic Cholecystectomy Using the da Vinci System

    PubMed Central

    Kang, Chang Moo; Chi, Hoon Sang; Hyeung, Woo Jin; Kim, Kyung Sik; Choi, Jin Sub; Kim, Byong Ro

    2007-01-01

    With the advancement of laparoscopic instruments and computer sciences, complex surgical procedures are expected to be safely performed by robot assisted telemanipulative laparoscopic surgery. The da Vinci system (Intuitive Surgical, Mountain View, CA, USA) became available at the many surgical fields. The wrist like movements of the instrument's tip, as well as 3-dimensional vision, could be expected to facilitate more complex laparoscopic procedure. Here, we present the first Korean experience of da Vinci robotic assisted laparoscopic cholecystectomy and discuss the introduction and perspectives of this robotic system. PMID:17594166

  18. Leonardo da Vinci and Kethem-Kiveris vena.

    PubMed

    Dolezal, Antonín; Skorepova-Honzlova, Zita; Jelen, Karel

    2012-01-01

    In the drawing of coitus by Leonardo da Vinci are pictured the contemporary hypotheses regarding this act. The authors analyze the mamillaruteral connection depicted by the artist and grow up to believe that this is a hypothetical kiveris vena, female vein described by Anatomist Master Nicolai Physicus from the Salerno School. The Hebrew roots were found in the name. The connection is described also by Mondino in The Anathomia. The same connection can be found in the picture of the pregnant woman in Fasciculus Medicinæ by Johannes De Ketham.

  19. Insight into the da Vinci® Xi - technical notes for single-docking left-sided colorectal procedures.

    PubMed

    Ngu, James Chi-Yong; Sim, Sarah; Yusof, Sulaiman; Ng, Chee-Yung; Wong, Andrew Siang-Yih

    2017-12-01

    The adoption of robot-assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi-quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left-sided colorectal procedures. Our initial series of left-sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Between March 2015 and April 2016, 54 cases of robot-assisted laparoscopic left-sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi-quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. The da Vinci® Xi simplifies the docking procedure and makes single-docking feasible for multi-quadrant left-sided colorectal procedures. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Transoral robotic thyroidectomy: a preclinical feasibility study using the da Vinci Xi platform.

    PubMed

    Russell, Jonathon O; Noureldine, Salem I; Al Khadem, Mai G; Chaudhary, Hamad A; Day, Andrew T; Kim, Hoon Yub; Tufano, Ralph P; Richmon, Jeremy D

    2017-09-01

    Transoral thyroid surgery allows the surgeon to conceal incisions within the oral cavity without significantly increasing the amount of required dissection. TORT provides an ideal scarless, midline access to the thyroid gland and bilateral central neck compartments. This approach, however, presents multiple technical challenges. Herein, we present our experience using the latest generation robotic surgical system to accomplish transoral robotic thyroidectomy (TORT). In two human cadavers, the da Vinci Xi surgical system (Intuitive Surgical, Sunnyvale, CA, USA) was used to complete TORT. Total thyroidectomy and bilateral central neck dissection was successfully completed in both cadavers. The da Vinci Xi platform offered several technologic advantages over previous robotic generations including overhead docking, narrower arms, and improved range of motion allowing for improved execution of previously described TORT techniques.

  1. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    PubMed

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the

  2. Da Vinci Xi and Si platforms have equivalent perioperative outcomes during robot-assisted partial nephrectomy: preliminary experience.

    PubMed

    Abdel Raheem, Ali; Sheikh, Abulhasan; Kim, Dae Keun; Alatawi, Atalla; Alabdulaali, Ibrahim; Han, Woong Kyu; Choi, Young Deuk; Rha, Koon Ho

    2017-03-01

    The aims of this study were to compare the perioperative outcomes of da Vinci Xi to Si during robotic-assisted partial nephrectomy (RAPN) and to discuss the feasibility of our novel port placement scheme for the da Vinci Xi platform, to overcome the existing kinetic and technical difficulties we faced with the linear port placement in patients with a small body habitus. A retrospective data analysis of patients who underwent RPN using da Vinci Xi (n = 18) was carried out. The outcomes of the Xi group were compared with the Si group (n = 18) selected using a case-matched methodology. For da Vinci Xi, we applied the universal linear port placement in 12 patients and our modified port placement in the remaining 6 patients. The Xi group had a shorter mean docking time of 17.8 ± 2.6 min compared to the Si group of 20.5 ± 2.1 min (p = 0.002); otherwise, no significant difference was present with regard to the remaining perioperative variables (p > 0.05). The modified Xi port placement had a shorter mean console time of 70.8 ± 9.7 min compared to the universal linear port placement of 89.3 ± 17.2 min (p = 0.03). Moreover, it provided a broader field of vision with excellent robotic arms movement, minimizing collisions and allowing an easier and comfortable surgical assist. Da Vinci Xi appears to be feasible and safe during RPN with similar outcomes to Si. The novel Xi port placement makes surgery easier in patients with low BMI.

  3. Da Vinci's codex and the anatomy of healthcare.

    PubMed

    Stephens-Borg, Keith

    2012-08-01

    We usually display a laid-back approach to medical jargon throughout our theatre work. The word 'perioperative' is built from the Greek word 'peri' (around) and the Latin 'operari' (to work). Latin and Greek became the prefixed language of choice for Leonardo da Vinci, and his research was pivotal in determining the way in which surgical procedures are documented. Ancient manuscripts aided the unfolding of the secrets of anatomy, and Leonardo revealed that art was the key in expressive detailed explanation.

  4. The Da Vinci European BioBank: A Metabolomics-Driven Infrastructure

    PubMed Central

    Carotenuto, Dario; Luchinat, Claudio; Marcon, Giordana; Rosato, Antonio; Turano, Paola

    2015-01-01

    We present here the organization of the recently-constituted da Vinci European BioBank (daVEB, https://www.davincieuropeanbiobank.org/it). The biobank was created as an infrastructure to support the activities of the Fiorgen Foundation (http://www.fiorgen.net/), a nonprofit organization that promotes research in the field of pharmacogenomics and personalized medicine. The way operating procedures concerning samples and data have been developed at daVEB largely stems from the strong metabolomics connotation of Fiorgen and from the involvement of the scientific collaborators of the foundation in international/European projects aimed to tackle the standardization of pre-analytical procedures and the promotion of data standards in metabolomics. PMID:25913579

  5. Opportunity cost in the economic evaluation of da Vinci robotic assisted surgery.

    PubMed

    Fuertes-Guiró, Fernando; Girabent-Farrés, Montserrat; Viteri-Velasco, Eduardo

    2016-04-01

    This study aims to demonstrate the importance of the opportunity cost in using da Vinci robotic surgery, assisted by a comprehensive review of the literature to determine the differences in the total cost of surgery and operative time in traditional laparoscopic surgery and da Vinci robotic surgery. We identified the studies comparing the use of traditional laparoscopic surgery with robotics during the period 2002-2012 in the electronic economic evaluation databases, and another electronic search was performed for publications by Spanish hospitals in the same period to calculate the opportunity cost. A meta-analysis of response variables considering the total cost of the intervention and surgical time was completed using the items selected in the first revision, and their differences were analyzed. We then calculated the opportunity cost represented by these time differences using the data obtained from the studies in the second review of the literature. Nine items were selected in the first review and three in the second. Traditional laparoscopic surgery has a lower cost than the da Vinci (p < 0.00001). Robotic surgery takes longer (8.0-65.5 min) than traditional surgery (p < 0.00001), and this difference represents an average opportunity cost for robot use of € 489.98, with a unit cost factor/time which varies according to the pathology dealt with, from € 8.2 to 18.7/min. The opportunity cost is a quantity that must be included in the total cost of using a surgical technology within an economic cost analysis in the context of an economic evaluation.

  6. Comparing the da Vinci si single console and dual console in teaching novice surgeons suturing techniques.

    PubMed

    Crusco, Salvatore; Jackson, Tiffany; Advincula, Arnold

    2014-01-01

    Robot-assisted laparoscopic surgery is often taught with the surgical mentor at the surgeon console and the trainee at the patient's bedside. The da Vinci dual console (Intuitive Surgical, Sunnyvale, California) allows a surgical mentor to teach with both the mentor and the trainee working at a surgeon console simultaneously. The purpose of this study is to evaluate the effectiveness of the dual console versus the single console for teaching medical students robotic tasks. Forty novice medical students were randomized to either the da Vinci single-console or dual-console group and were taught 4 knot-tying techniques by a surgical mentor. The students were timed while performing the tasks. No statistically significant differences in mean task times were observed between the single- and dual-console groups: interrupted stitch with a 2-handed knot (300 seconds for single vs 294 seconds for dual, P=.59), interrupted stitch with a 1-handed knot (198 seconds for single vs 212 seconds for dual, P=.88), figure-of-8 stitch with a 2-handed knot (261 seconds for single vs 219 seconds for dual, P=.20), and figure-of-8 stitch with a 1-handed knot (200 seconds for single vs 199 seconds for dual, P=.53). No significant difference was observed in performance time when teaching knot-tying techniques to medical students using the da Vinci dual console compared with the single console. More research needs to be performed on the utility of the da Vinci dual console in surgical training.

  7. Comparing the da Vinci Si Single Console and Dual Console in Teaching Novice Surgeons Suturing Techniques

    PubMed Central

    Jackson, Tiffany; Advincula, Arnold

    2014-01-01

    Background and Objectives: Robot-assisted laparoscopic surgery is often taught with the surgical mentor at the surgeon console and the trainee at the patient's bedside. The da Vinci dual console (Intuitive Surgical, Sunnyvale, California) allows a surgical mentor to teach with both the mentor and the trainee working at a surgeon console simultaneously. The purpose of this study is to evaluate the effectiveness of the dual console versus the single console for teaching medical students robotic tasks. Methods: Forty novice medical students were randomized to either the da Vinci single-console or dual-console group and were taught 4 knot-tying techniques by a surgical mentor. The students were timed while performing the tasks. Results: No statistically significant differences in mean task times were observed between the single- and dual-console groups: interrupted stitch with a 2-handed knot (300 seconds for single vs 294 seconds for dual, P = .59), interrupted stitch with a 1-handed knot (198 seconds for single vs 212 seconds for dual, P = .88), figure-of-8 stitch with a 2-handed knot (261 seconds for single vs 219 seconds for dual, P = .20), and figure-of-8 stitch with a 1-handed knot (200 seconds for single vs 199 seconds for dual, P = .53). Conclusion: No significant difference was observed in performance time when teaching knot-tying techniques to medical students using the da Vinci dual console compared with the single console. More research needs to be performed on the utility of the da Vinci dual console in surgical training. PMID:25392618

  8. Face, content, and construct validity of four, inanimate training exercises using the da Vinci ® Si surgical system configured with Single-Site ™ instrumentation.

    PubMed

    Jarc, Anthony M; Curet, Myriam

    2015-08-01

    Validated training exercises are essential tools for surgeons as they develop technical skills to use robot-assisted minimally invasive surgical systems. The purpose of this study was to show face, content, and construct validity of four, inanimate training exercises using the da Vinci (®) Si surgical system configured with Single-Site (™) instrumentation. New (N = 21) and experienced (N = 6) surgeons participated in the study. New surgeons (11 Gynecology [GYN] and 10 General Surgery [GEN]) had not completed any da Vinci Single-Site cases but may have completed multiport cases using the da Vinci system. They participated in this study prior to attending a certification course focused on da Vinci Single-Site instrumentation. Experienced surgeons (5 GYN and 1 GEN) had completed at least 25 da Vinci Single-Site cases. The surgeons completed four inanimate training exercises and then rated them with a questionnaire. Raw metrics and overall normalized scores were computed using both video recordings and kinematic data collected from the surgical system. The experienced surgeons significantly outperformed new surgeons for many raw metrics and the overall normalized scores derived from video review (p < 0.05). Only one exercise did not achieve a significant difference between new and experienced surgeons (p = 0.08) when calculating an overall normalized score using both video and advanced metrics derived from kinematic data. Both new and experienced surgeons rated the training exercises as appearing, to train and measure technical skills used during da Vinci Single-Site surgery and actually testing the technical skills used during da Vinci Single-Site surgery. In summary, the four training exercises showed face, content, and construct validity. Improved overall scores could be developed using additional metrics not included in this study. The results suggest that the training exercises could be used in an overall training curriculum aimed at developing proficiency in

  9. Photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot

    NASA Astrophysics Data System (ADS)

    Gandhi, Neeraj; Allard, Margaret; Kim, Sungmin; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2017-12-01

    Death and paralysis are significant risks of modern surgeries, caused by injury to blood vessels and nerves hidden by bone and other tissue. We propose an approach to surgical guidance that relies on photoacoustic (PA) imaging to determine the separation between these critical anatomical features and to assess the extent of safety zones during surgical procedures. Images were acquired as an optical fiber was swept across vessel-mimicking targets, in the absence and presence of teleoperation with a research da Vinci Surgical System. Vessel separation distances were measured directly from PA images. Vessel positions were additionally recorded based on the fiber position (calculated from the da Vinci robot kinematics) that corresponded to an observed PA signal, and these recordings were used to indirectly measure vessel separation distances. Amplitude- and coherence-based beamforming were used to estimate vessel separations, resulting in 0.52- to 0.56-mm mean absolute errors, 0.66- to 0.71-mm root-mean-square errors, and 65% to 68% more accuracy compared to fiber position measurements obtained through the da Vinci robot kinematics. Similar accuracy was achieved in the presence of up to 4.5-mm-thick ex vivo tissue. Results indicate that PA image-based measurements of the separation among anatomical landmarks could be a viable method for real-time path planning in multiple interventional PA applications.

  10. [Applicability of the da Vinci robotic system in the skull base surgical approach. Preclinical investigation].

    PubMed

    Fernandez-Nogueras Jimenez, Francisco J; Segura Fernandez-Nogueras, Miguel; Jouma Katati, Majed; Arraez Sanchez, Miguel Ángel; Roda Murillo, Olga; Sánchez Montesinos, Indalecio

    2015-01-01

    The role of robotic surgery is well established in various specialties such as urology and general surgery, but not in others such as neurosurgery and otolaryngology. In the case of surgery of the skull base, it has just emerged from an experimental phase. To investigate possible applications of the da Vinci surgical robot in transoral skull base surgery, comparing it with the authors' experience using conventional endoscopic transnasal surgery in the same region. A transoral transpalatal approach to the nasopharynx and medial skull base was performed on 4 cryopreserved cadaver heads. We used the da Vinci robot, a 30° standard endoscope 12mm thick, dual camera and dual illumination, Maryland forceps on the left terminal and curved scissors on the right, both 8mm thick. Bone drilling was performed manually. For the anatomical study of this region, we used 0.5cm axial slices from a plastinated cadaver head. Various skull base structures at different depths were reached with relative ease with the robot terminals Transoral robotic surgery with the da Vinci system provides potential advantages over conventional endoscopic transnasal surgery in the surgical approach to this region. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  11. Transparency of Vocational Qualifications: The Leonardo da Vinci Approach. CEDEFOP Panorama Series.

    ERIC Educational Resources Information Center

    Bjornavold, Jens; Pettersson, Sten

    This report gives an overview of the situation of transparency of vocational qualifications by presenting measures introduced at the European Community level and by drawing attention to projects within the Leonardo da Vinci Program dealing with the issue. A 16-page executive summary appears first. Chapter 1 provides general background and aims.…

  12. Da Vinci© Skills Simulator™: is an early selection of talented console surgeons possible?

    PubMed

    Meier, Mark; Horton, Kevin; John, Hubert

    2016-12-01

    To investigate whether the learning curve of robotic surgery simulator training depends on the probands' characteristics, such as age and prior experience, we conducted a study of six distinct proband groups, using the da Vinci Skills Simulator: experienced urological robotic surgeons, surgeons with experience as da Vinci tableside assistants, urological surgeons with laparoscopic experience, urological surgeons without laparoscopic experience, and complete novices aged 25 and younger and 40 and older. The results showed that all experienced robotic surgeons reached expert level (>90 %, as defined previously in the literature) within the first three repetitions and remained on a high level of performance. All other groups performed worse. Tableside assistants, laparoscopically experienced surgeons, and younger novices showed a better performance in all exercises than surgeons without laparoscopic experience and older novices. A linear mixed-effects model analysis demonstrated no significant difference in learning curves between proband groups in all exercises except the RW1 exercise for the younger proband group. In summary, we found that performance in robotic surgery, measured by performance scores in three virtual simulator modules using the EndoWrist techniques, was dependent on age and prior experience with robotic and laparoscopic surgery. However, and most importantly, the learning curve was not significantly affected by these factors. This suggests that the da Vinci Skills Simulator™ is a useful practice tool for everyone learning or performing robotic surgery, and that early selection of talented surgeons is neither possible nor necessary.

  13. Evaluation of robotic-assisted platysmaplasty procedures in a cadaveric model using the da Vinci Surgical System.

    PubMed

    Taghizadeh, Farhan; Reiley, Carol; Mohr, Catherine; Paul, Malcolm

    2014-03-01

    We are evaluating the technical feasibility of robotic-assisted laparoscopic vertical-intermediate platysmaplasty in conjunction with an open rhytidectomy. In a cadaveric study, the da Vinci Surgical System was used to access certain angles in the lower neck that are difficult for traditional short incision, short flap procedures. Ergonomics, approach, and technical challenges were noted. To date, there are no published reports of robotic-assisted neck lifts, motivating us to assess its potential in this field of plastic surgery. Standard open technique short flap rhytidectomies with concurrent experimental robotic-assisted platysmaplasties (neck lifts) were performed on six cadavers with the da Vinci Si Surgical System(®) (Intuitive Surgical, Sunnyvale, CA, USA). The surgical procedures were performed on a diverse cadaver population from June 2011 to January 2012. The procedures included (1) submental incision and laser-assisted liposuction, (2) open rhytidectomy, and (3) robotic-assisted platysmaplasty using knot-free sutures. A variety of sutures and fat extraction techniques, coupled with 0° and 30° three-dimensional endoscopes, were utilized to optimize visualization of the platysma. An unaltered da Vinci Si Surgical System with currently available instruments was easily adaptable to neck lift surgery. Mid-neck platysma exposure was excellent, tissue handling was delicate and precise, and suturing was easily performed. Robotic-assisted surgery has the potential to improve outcomes in neck lifts by offering the ability to manipulate instruments with increased freedom of movement, scaled motion, tremor reduction, and stereoscopic three-dimensional visualization in the deep neck. Future clinical studies on live human patients can better assess subject and surgeon benefits arising from the use of the da Vinci system for neck lifts. Evidence obtained from multiple time series with or without the intervention, such as case studies. Dramatic results in

  14. The uncatchable smile in Leonardo da Vinci's La Bella Principessa portrait.

    PubMed

    Soranzo, Alessandro; Newberry, Michelle

    2015-08-01

    A portrait of uncertain origin recently came to light which, after extensive research and examination, was shown to be that rarest of things: a newly discovered Leonardo da Vinci painting entitled La Bella Principessa. This research presents a new illusion which is similar to that identified in the Mona Lisa; La Bella Principessa's mouth appears to change slant depending on both the Viewing Distance and the Level of Blur applied to a digital version of the portrait. Through a series of psychophysics experiments, it was found that a perceived change in the slant of the La Bella Principessa's mouth influences her expression of contentment thus generating an illusion that we have coined the "uncatchable smile". The elusive quality of the Mona Lisa's smile has been previously reported (Science, 290 (2000) 1299) and so the existence of a similar illusion in a portrait painted prior to the Mona Lisa becomes more interesting. The question remains whether Leonardo da Vinci intended this illusion. In any case, it can be argued that the ambiguity created adds to the portrait's allure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. [The Vitruvian Man: an anatomical drawing for proportions by Leonardo Da Vinci].

    PubMed

    Le Floch-Prigent, P

    2008-12-01

    The aim of the study was to find out and to analyse the text by Vitruvius which inspired the famous drawing by Leonardo da Vinci (circa 1490) kept in the Galleria dell'Accademia, in Venezia, Italy: the man inscribed in one circle and in one square. The book "de Architectura" by Vitruvius Marcus Pollio was printed several times since the Renaissance when both the roman architecture of antiquity and this text became very popular. From a French translation by Claude Perrault in 1864, it became easy to find a French translation with the original text in Latin (Paris, 2003, Les Belles Lettres, French text by Pierre Gros). The drawing by Leonardo da Vinci illustrates with great accuracy and fidelity the quotation of Vitruvius (with the exception of two of the 12 main relationships). The genius of Leonardo da Vinci was to keep only one trunk, head and neck for two pairs of limbs: scapular and pelvic; to make the circle tangent to the lower edge of the square; to adjust a few features of the quotation for the equilibrium of the whole figure; and of course to bring his incredible skill as a drawer (one of the best of his century). The drawing was made on a sheet of paper 344x245mm, in black ink which became dark brown with time; several lines complete the figure above and below; a short caption and a horizontal scale appear just under the drawing. The celebrity of the drawing, a symbol of the Renaissance, of the equilibrium of man and mankind, of the universality of the artists and intellectuals of the time (Humanism) made it iconic and it has been constantly reproduced and adapted especially for advertisement and logos, not only in the medical field.

  16. Initial experience with the new da Vinci single-port robot-assisted platform.

    PubMed

    Ballestero Diego, R; Zubillaga Guerrero, S; Truan Cacho, D; Carrion Ballardo, C; Velilla Diez, G; Calleja Hermosa, P; Gutiérrez Baños, J L

    2017-06-01

    To describe our experience in the first cases of urological surgeries performed with the da Vinci single-port robot-assisted platform. We performed 5 single-port robot-assisted surgeries (R-LESS) between May and October 2014. We performed 3 ureteral reimplant surgeries, one ureteropyeloplasty in an inverted kidney and 1 partial nephrectomy. The perioperative and postoperative results were collected, as well as a report of the complications according to the Clavien classification system. Of the 5 procedures, 4 were performed completely by LESS, while 1 procedure was reconverted to multiport robot-assisted surgery. There were no intraoperative complications. We observed perioperative complications in 4 patients, all of which were grade 1 or 2. The mean surgical time was 262minutes (range, 230-300). In our initial experience with the da Vinci device, R-LESS surgery was feasible and safe. There are still a number of limitations in its use, which require new and improved R-LESS platforms. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. [History of robotics: from Archytas of Tarentum until da Vinci robot. (Part I)].

    PubMed

    Sánchez Martín, F M; Millán Rodríguez, F; Salvador Bayarri, J; Palou Redorta, J; Rodríguez Escovar, F; Esquena Fernández, S; Villavicencio Mavrich, H

    2007-02-01

    Robotic surgery is the newst technologic option in urology. To understand how new robots work is interesting to know their history. The desire to design machines imitating humans continued for more than 4000 years. There are references to King-su Tse (clasic China) making up automaton at 500 a. C. Archytas of Tarentum (at around 400 a.C.) is considered the father of mechanical engineering, and one of the occidental robotics classic referents. Heron of Alexandria, Hsieh-Fec, Al-Jazari, Roger Bacon, Juanelo Turriano, Leonardo da Vinci, Vaucanson o von Kempelen were robot inventors in the middle age, renaissance and classicism. At the XIXth century, automaton production underwent a peak and all engineering branches suffered a great development. At 1942 Asimov published the three robotics laws, based on mechanics, electronics and informatics advances. At XXth century robots able to do very complex self governing works were developed, like da Vinci Surgical System (Intuitive Surgical Inc, Sunnyvale, CA, USA), a very sophisticated robot to assist surgeons.

  18. LEONARDO DA VINCI AND THE ORIGIN OF SEMEN.

    PubMed

    Noble, Denis; DiFrancesco, Dario; Zancani, Diego

    2014-12-20

    It is well known that Leonardo da Vinci made several drawings of the human male anatomy. The early drawings (before 1500) were incorrect in identifying the origin of semen, where he followed accepted teaching of his time. It is widely thought that he did not correct this mistake, a view that is reflected in several biographies. In fact, he made a later drawing (after 1500) in which the description of the anatomy is remarkably accurate and must have been based on careful dissection. In addition to highlighting this fact, acknowledged previously in only one other source, this article reviews the background to Leonardo's knowledge of the relevant anatomy.

  19. Leonardo da Vinci and the origin of semen

    PubMed Central

    Noble, Denis; DiFrancesco, Dario; Zancani, Diego

    2014-01-01

    It is well known that Leonardo da Vinci made several drawings of the human male anatomy. The early drawings (before 1500) were incorrect in identifying the origin of semen, where he followed accepted teaching of his time. It is widely thought that he did not correct this mistake, a view that is reflected in several biographies. In fact, he made a later drawing (after 1500) in which the description of the anatomy is remarkably accurate and must have been based on careful dissection. In addition to highlighting this fact, acknowledged previously in only one other source, this article reviews the background to Leonardo's knowledge of the relevant anatomy. PMID:27494016

  20. Preliminary experience in laparoscopic resection of hepatic hydatidectocyst with the Da Vinci Surgical System (DVSS): a case report.

    PubMed

    Zou, Haibo; Luo, Lanyun; Xue, Hua; Wang, Guan; Wang, Xiankui; Luo, Le; Yao, Yutong; Xiang, Guangming; Huang, Xiaolun

    2017-09-11

    At present, Da Vinci robotic assisted hepatectomy has been routinely carried out in conditional units. But there is no report concerning the use of Da Vinci robots for hepatic hydatid cystectomy and experience on this aspect is seldom mentioned before. This study was to summarize the preliminary experience in laparoscopic resection of hepatic hydatidectocyst with the Da Vinci Surgical System (DVSS). A 29-year-old female diagnosed as hepatic hydatid in the right anterior lobe of liver was treated with laparoscopic resection by the DVSS under general anesthesia. Appropriate disposal of tumor cell in vascular system and disinfection of surgical field with hypertonic saline were conducted. The hepatic hydatidectocyst was resected completely with an operation time of 130 min, an intraoperative blood loss of 200 ml and a length of hospital stay for five days. The vital signs of patient were stable and no cyst fluid allergy occurred after operation. Our result showed that laparoscopic resection of hepatic hydatidectocyst by using the DVSS is safe and feasible on the basis of hospitals have rich experience in treatment of cystic echinococcosisliver, resection with DVSS and laparoscopic excision.

  1. Impact of IQ, computer-gaming skills, general dexterity, and laparoscopic experience on performance with the da Vinci surgical system.

    PubMed

    Hagen, Monika E; Wagner, Oliver J; Inan, Ihsan; Morel, Philippe

    2009-09-01

    Due to improved ergonomics and dexterity, robotic surgery is promoted as being easily performed by surgeons with no special skills necessary. We tested this hypothesis by measuring IQ elements, computer gaming skills, general dexterity with chopsticks, and evaluating laparoscopic experience in correlation to performance ability with the da Vinci robot. Thirty-four individuals were tested for robotic dexterity, IQ elements, computer-gaming skills and general dexterity. Eighteen surgically inexperienced and 16 laparoscopically trained surgeons were included. Each individual performed three different tasks with the da Vinci surgical system and their times were recorded. An IQ test (elements: logical thinking, 3D imagination and technical understanding) was completed by each participant. Computer skills were tested with a simple computer game (hand-eye coordination) and general dexterity was evaluated by the ability to use chopsticks. We found no correlation between logical thinking, 3D imagination and robotic skills. Both computer gaming and general dexterity showed a slight but non-significant improvement in performance with the da Vinci robot (p > 0.05). A significant correlation between robotic skills, technical understanding and laparoscopic experience was observed (p < 0.05). The data support the conclusion that there are no significant correlations between robotic performance and logical thinking, 3D understanding, computer gaming skills and general dexterity. A correlation between robotic skills and technical understanding may exist. Laparoscopic experience seems to be the strongest predictor of performance with the da Vinci surgical system. Generally, it appears difficult to determine non-surgical predictors for robotic surgery.

  2. Robotic Colorectal Resection With and Without the Use of the New Da Vinci Table Motion: A Case-Matched Study.

    PubMed

    Palmeri, Matteo; Gianardi, Desirée; Guadagni, Simone; Di Franco, Gregorio; Bastiani, Luca; Furbetta, Niccolò; Simoncini, Tommaso; Zirafa, Cristina; Melfi, Franca; Buccianti, Piero; Moglia, Andrea; Cuschieri, Alfred; Mosca, Franco; Morelli, Luca

    2018-06-01

    The da Vinci Table Motion (dVTM) is a new device that enables patients to be repositioned with instruments in place within the abdomen, and without undocking the robot. The present study was designed to compare operative and short-term outcomes of patients undergoing colorectal cancer surgery with the da Vinci Xi system, with or without use of the dVTM. Ten patients underwent robotic colorectal resection for cancer with the use of dVTM (Xi-dVTM group) between May 2015 and October 2015 at our center. The intraoperative and short-term clinical outcome were compared, using a case-control methodology (propensity scores approach to create 1:2 matched pairs), with a similar group of patients who underwent robotic colorectal surgery for cancer without the use of the dVTM device (Xi-only group). Overall robotic operative time was shorter in the Xi-dVTM group ( P = .04). Operations were executed fully robotic in all Xi-dVTM cases, while 2 cases of the Xi-only group required conversion to open surgery because of bulky tumors and difficult exposure. Postoperative medical complications were higher in the Xi-only group ( P = .024). In this preliminary experience, the use of the new dVTM with the da Vinci Xi in colorectal surgery, by overcoming the limitations of the fixed positions of the patient, enhanced the workflow and resulted in improved exposure of the operative field. Further studies with a greater number of patients are needed to confirm these benefits of the dVTM-da Vinci Xi robotically assisted colorectal surgery.

  3. Magnetisches Tracking für die Navigation mit dem da Vinci® Surgical System

    NASA Astrophysics Data System (ADS)

    Nickel, Felix; Wegner, Ingmar; Kenngott, Hannes; Neuhaus, Jochen; Müller-Stich, Beat P.; Meinzer, Hans-Peter; Gutt, Carsten N.

    In dieser Studie wurde untersucht ob in einem typischen OP-Aufbau mit dem da Vinci® Telemanipulator elektromagnetisches Tracking für die Realisation eines Navigationssystems eingesetzt werden kann. Hierfür wurde in einem realen OP-Aufbau untersucht, wie stark metallische und ferromagnetisch wirksame Objekte wie Operationstisch und Telemanipulator das elektromagnetische Feld des Trackingsystems beeinflussen. Die Ergebnisse zeigen, dass der Telemanipulator nur unwesentlich die Störung des Magnetfeldes durch den OP-Tisch verstärkt. Insbesondere die Bewegung der Instrumente im Trackingvolumen verursachte keine zusätzliche relevante Störung des Magnetfeldes. Bei Begrenzung des Trackingvolumens auf eine Länge von 190 mm, Höhe von 200mm und Breite von 400 mm war der maximale Fehler in diesem Bereich an allen Messpunkten kleiner 10 mm. Der Einsatz von elektromagnetischem Tracking für die Navigation mit dem da Vinci® Surgical System ist somit in einem begrenzten Arbeitsvolumen mit hinreichender Genauigkeit möglich.

  4. Visual tracking of da Vinci instruments for laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Kuhn, E.; Bodenstedt, S.; Röhl, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.

    2014-03-01

    Intraoperative tracking of laparoscopic instruments is a prerequisite to realize further assistance functions. Since endoscopic images are always available, this sensor input can be used to localize the instruments without special devices or robot kinematics. In this paper, we present an image-based markerless 3D tracking of different da Vinci instruments in near real-time without an explicit model. The method is based on different visual cues to segment the instrument tip, calculates a tip point and uses a multiple object particle filter for tracking. The accuracy and robustness is evaluated with in vivo data.

  5. Da Vinci single site© surgical platform in clinical practice: a systematic review.

    PubMed

    Morelli, Luca; Guadagni, Simone; Di Franco, Gregorio; Palmeri, Matteo; Di Candio, Giulio; Mosca, Franco

    2016-12-01

    The Da Vinci single-site© surgical platform (DVSSP) is a set of single-site instruments and accessories specifically dedicated to robot-assisted single-site surgery. The PubMed database from inception to June 2015 was searched for English literature on the clinical use of DVSSP in general surgery, urology and gynecology. Twenty-nine articles involving the clinical application of DVSSP were identified; 15 articles on general surgery (561 procedures), four articles on urology (48 procedures) and 10 articles on gynecology (212 procedures). All studies have proven the safety and feasibility of the use of DVSSP. The principal reported advantage is the restoration of intra-abdominal triangulation, while the main reported limitation is the lack of the endowrist. Da Vinci systems have proven to be valuable assets in single-site surgery, owing to the combination of robot use with the dedicated single-incision platform. However, case-control or prospective trials are warranted to draw more definitive conc lusions. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Mammary artery harvesting using the Da Vinci Si robotic system

    PubMed Central

    Canale, Leonardo Secchin; Bonatti, Johannes

    2014-01-01

    Internal mammary artery harvesting is an essential part of any coronary artery bypass operation. Totally endoscopic coronary artery bypass graft surgery has become reality in many centers as a safe and effective alternative to conventional surgery in selected patients. Internal mammary artery harvesting is the initial part of the procedure and should be performed equally safely if one wants to achieve excellence in patency rates for the bypass. We here describe the technique for mammary harvesting with the Da Vinci Si robotic system. PMID:24896171

  7. Leonardo da Vinci, One Year on...a Different Look at Vocational Training in Europe.

    ERIC Educational Resources Information Center

    Le Magazine, 1996

    1996-01-01

    Discusses the success of the Leonardo da Vinci program, a European laboratory of innovation in vocational training, a priority focus of investment in human resources and intelligence, and a way to mobilize innovative forces beyond national boundaries. Trends identified by the program focus on new information and communication technologies. (JOW)

  8. Early assessment of feasibility and technical specificities of transoral robotic surgery using the da Vinci Xi.

    PubMed

    Gorphe, Philippe; Von Tan, Jean; El Bedoui, Sophie; Hartl, Dana M; Auperin, Anne; Qassemyar, Quentin; Moya-Plana, Antoine; Janot, François; Julieron, Morbize; Temam, Stephane

    2017-12-01

    The latest generation Da Vinci ® Xi™ Surgical System Robot released has not been evaluated to date in transoral surgery for head and neck cancers. We report here the 1-year results of a non-randomized phase II multicentric prospective trial aimed at assessing its feasibility and technical specificities. Our primary objective was to evaluate the feasibility of transoral robotic surgery using the da Vinci ® Xi™ Surgical System Robot. The secondary objective was to assess peroperative outcomes. Twenty-seven patients, mean age 62.7 years, were included between May 2015 and June 2016 with tumors affecting the following sites: oropharynx (n = 21), larynx (n = 4), hypopharynx (n = 1), parapharyngeal space (n = 1). Eighteen patients were included for primary treatment, three for a local recurrence, and six for cancer in a previously irradiated field. Three were reconstructed with a FAMM flap and 6 with a free ALT flap. The mean docking time was 12 min. "Chopsticking" of surgical instruments was very rare. During hospitalization following surgery, 3 patients experienced significant bleeding between day 8 and 9 that required surgical transoral hemostasis (n = 1) or endovascular embolization (n = 2). Transoral robotic surgery using the da Vinci ® Xi™ Surgical System Robot proved feasible with technological improvements compared to previous generation surgical system robots and with a similar postoperative course. Further technological progress is expected to be of significant benefit to the patients.

  9. Realization of a single image haze removal system based on DaVinci DM6467T processor

    NASA Astrophysics Data System (ADS)

    Liu, Zhuang

    2014-10-01

    Video monitoring system (VMS) has been extensively applied in domains of target recognition, traffic management, remote sensing, auto navigation and national defence. However the VMS has a strong dependence on the weather, for instance, in foggy weather, the quality of images received by the VMS are distinct degraded and the effective range of VMS is also decreased. All in all, the VMS performs terribly in bad weather. Thus the research of fog degraded images enhancement has very high theoretical and practical application value. A design scheme of a fog degraded images enhancement system based on the TI DaVinci processor is presented in this paper. The main function of the referred system is to extract and digital cameras capture images and execute image enhancement processing to obtain a clear image. The processor used in this system is the dual core TI DaVinci DM6467T - ARM@500MHz+DSP@1GH. A MontaVista Linux operating system is running on the ARM subsystem which handles I/O and application processing. The DSP handles signal processing and the results are available to the ARM subsystem in shared memory.The system benefits from the DaVinci processor so that, with lower power cost and smaller volume, it provides the equivalent image processing capability of a X86 computer. The outcome shows that the system in this paper can process images at 25 frames per second on D1 resolution.

  10. Gastrointestinal stromal tumours of stomach: Robot-assisted excision with the da Vinci Surgical System regardless of size and location site.

    PubMed

    Furbetta, Niccolo; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gianardi, Desirée; Latteri, Saverio; Marciano, Emanuele; Moglia, Andrea; Cuschieri, Alfred; Di Candio, Giulio; Mosca, Franco; Morelli, Luca

    2018-03-23

    The role of minimally invasive surgery of gastrointestinal stromal tumours (GISTs) of the stomach remains uncertain especially for large and/or difficult located tumours. We are hereby presenting a single-centre series of robot-assisted resections using the da Vinci Surgical System (Si or Xi). Data of patients undergoing robot-assisted treatment of gastric GIST were retrieved from the prospectively collected institutional database and a retrospective analysis was performed. Patients were stratified according to size and location of the tumour. Difficult cases (DCs) were considered for size if tumour was> 50 mm and/or for location if the tumour was Type II, III or IV sec. Privette/Al-Thani classification. Between May 2010 and February 2017, 12 consecutive patients underwent robot-assisted treatment of GIST at our institution. DCs were 10/12 cases (83.3%), of which 6/10 (50%) for location, 2/10 (25%) for size and 2/10 (25%) for both. The da Vinci Si was used in 8 patients, of which 6 (75%) were DC, and the da Vinci Xi in 4, all of which (100%) were DC. In all patients, excision was by wedge resection. All lesions had microscopically negative resection margins. There was no conversion to open surgery, no tumour ruptures or spillage and no intraoperative complications. Our experience suggests a positive role of the robot da Vinci in getting gastric GIST removal with a conservative approach, regardless of size and location site. Comparative studies with a greater number of patients are necessary for a more robust assessment.

  11. The Handedness of Leonardo da Vinci: A Tale of the Complexities of Lateralisation

    ERIC Educational Resources Information Center

    McManus, I. C.; Drury, Helena

    2004-01-01

    The handedness of Leonardo da Vinci is controversial. Although there is little doubt that many of his well-attributed drawings were drawn with the left hand, the hatch marks of the shading going downwards from left to right, it is not clear that he was a natural left-hander, there being some suggestion that he may have become left-handed as the…

  12. Roux-en-Y gastric bypass procedure performed with the da Vinci robot system: is it worth it?

    PubMed

    Hubens, G; Balliu, L; Ruppert, M; Gypen, B; Van Tu, T; Vaneerdeweg, W

    2008-07-01

    The Roux-en-Y gastric bypass procedure (RYGBP) is in many countries the gold standard for obtaining long-lasting weight reduction and improvement of obesity-related comorbidities. However, performing this operation by standard laparoscopic techniques requires important surgical skills because of the anastomoses involved. The da Vinci surgical robot system with its enhanced degrees of freedom in motion and three-dimensional vision is designed to overcome the difficulties encountered in traditional laparoscopic surgery with suturing and delicate tissue handling. For this study, 45 patients (9 men) with a mean body mass index (BMI) of 44.2 (range, 35.1-55.4) underwent RYGBP with the aid of the da Vinci robot system. They were compared with 45 consecutive patients with a mean BMI of 43.9 (range, 35.1-56.2) who underwent a laparoscopic RYGBP by the same surgeon during the same period. Overall, the total operating time was shorter for the laparoscopic cases (127 vs 212 min; p < 0.05). However, the last 10 robotic cases were performed in the same time span as the laparoscopic cases (136 vs 127 min). The total robotic setup time remained constant at about 30 min. There were no differences in postoperative complications between the two groups in terms of anastomotic leakage or stenosis. In the robotic group, more conversions to open surgery were noted. Early in the study, four patients (9%) had to undergo conversion to standard laparoscopic techniques due to inadequate setup of the robotic arms. Five patients (11%), however, had to undergo conversion to open surgery because of intestinal laceration during manipulation of the intestines with the robotic instruments. The costs were higher for robotic surgery than for standard laparoscopic RYGBP, mainly because of the extra equipment used, such as ultrasonic devices. The RYGBP procedure can be performed safely with the da Vinci robot after a learning curve of about 35 cases. At this writing, however, it is not clear whether

  13. Robotic single-access splenectomy using the Da Vinci Single-Site® platform: a case report.

    PubMed

    Corcione, Francesco; Bracale, Umberto; Pirozzi, Felice; Cuccurullo, Diego; Angelini, Pier Luigi

    2014-03-01

    Single-access laparoscopic splenectomy can offer patients some advantages. It has many difficulties, such as instrument clashing, lack of triangulation, odd angles and lack of space. The Da Vinci Single-Site® robotic surgery platform could decrease these difficulties. We present a case of single-access robotic splenectomy using this device. A 37 year-old female with idiopathic thrombocytopenic purpura was operated on with a single-site approach, using the Da Vinci Single-Site robotic surgery device. The procedure was successfully completed in 140 min. No intraoperative and postoperative complications occurred. The patient was discharged from hospital on day 3. Single-access robotic splenectomy seems to be feasible and safe using the new robotic single-access platform, which seems to overcome certain limits of previous robotic or conventional single-access laparoscopy. We think that additional studies should also be performed to explore the real cost-effectiveness of the platform. Copyright © 2013 John Wiley & Sons, Ltd.

  14. [Freud's identification with men who had 2 mothers: Oedipus, Leonardo da Vinci, Michealangelo and Moses].

    PubMed

    Harsch, H E

    1994-02-01

    In view of the fact that as a child Sigmund Freud was looked after by two mothers--his actual mother and a nursemaid--it is hardly surprising that traces of this pre-oedipal situation, fraught as it was with traumatisation and loss, should be discernible in the works of the creator of psychoanalysis. Freud's continued preoccupation with the Oedipus myth, his interest in "great men" like da Vinci and Michelangelo, and finally his identification with the figure of Moses are pointers not only to the paternal dimension (as long suggested by Freud's biographers) but also to the maternal dimension and its significance for Freud's life and work. The author demonstrates that those mythical and historical figures which Freud identified with--Oedipus, da Vinci, Michelangelo, Moses--themselves all had two mothers and sublimated this traumatic experience into outstanding achievements, the same being true of Freud himself "who solved the famous riddle and was a most powerful man".

  15. Design, Modelling and Teleoperation of a 2 mm Diameter Compliant Instrument for the da Vinci Platform.

    PubMed

    Francis, P; Eastwood, K W; Bodani, V; Looi, T; Drake, J M

    2018-05-07

    This work explores the feasibility of creating and accurately controlling an instrument for robotic surgery with a 2 mm diameter and a three degree-of-freedom (DoF) wrist which is compatible with the da Vinci platform. The instrument's wrist is composed of a two DoF bending notched-nitinol tube pattern, for which a kinematic model has been developed. A base mechanism for controlling the wrist is designed for integration with the da Vinci Research Kit. A basic teleoperation task is successfully performed using two of the miniature instruments. The performance and accuracy of the instrument suggest that creating and accurately controlling a 2 mm diameter instrument is feasible and the design and modelling proposed in this work provide a basis for future miniature instrument development.

  16. Preclinical cadaveric study of transanal endoscopic da Vinci® surgery.

    PubMed

    Hompes, R; Rauh, S M; Hagen, M E; Mortensen, N J

    2012-08-01

    Single-port platforms are increasingly being used for transanal surgery and may be associated with a shorter learning curve than transanal endoscopic microsurgery. However, these procedures remain technically challenging, and robotic technology could overcome some of the limitations and increase intraluminal manoeuvrability. An initial experimental experience with transanal endoscopic da Vinci(®) surgery (TEdS) using a glove port on human cadavers is reported. After initial dry laboratory experiments, the feasibility of TEdS and ideal set-up were further evaluated in human cadavers. For transanal access a glove port was constructed on-table by using a circular anal dilator, a standard wound retractor and a surgical glove. A da Vinci(®) Si HD system was used in combination with the glove port for transanal endoscopic resections. It was possible to perform all necessary tasks to complete a full-thickness excision and closure of the rectal wall, with cadavers in both prone and supine positions. The stable magnified view, combined with the EndoWrist(®) technology of the robotic instruments, made every task straightforward. Intraluminal manoeuvrability could be improved further by intersecting the robotic instruments. The glove port proved to be very reliable and the inherent flexibility of the glove facilitated docking of the robotic arms in a narrow confined space. Using a reliable and universally available glove port, TEdS was feasible and a preferred set-up was determined. Further clinical trials will be necessary to assess the safety and efficacy of this technique. Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  17. Total robotic radical rectal resection with da Vinci Xi system: single docking, single phase technique.

    PubMed

    Tamhankar, Anup Sunil; Jatal, Sudhir; Saklani, Avanish

    2016-12-01

    This study aims to assess the advantages of Da Vinci Xi system in rectal cancer surgery. It also assesses the initial oncological outcomes after rectal resection with this system from a tertiary cancer center in India. Robotic rectal surgery has distinct advantages over laparoscopy. Total robotic resection is increasing following the evolution of hybrid technology. The latest Da Vinci Xi system (Intuitive Surgical, Sunnyvale, USA) is enabled with newer features to make total robotic resection possible with single docking and single phase. Thirty-six patients underwent total robotic resection in a single phase and single docking. We used newer port positions in a straight line. Median distance from the anal verge was 4.5 cm. Median robotic docking time and robotic procedure time were 9 and 280 min, respectively. Median blood loss was 100 mL. One patient needed conversion to an open approach due to advanced disease. Circumferential resection margin and longitudinal resection margins were uninvolved in all other patients. Median lymph node yield was 10. Median post-operative stay was 7 days. There were no intra-operative adverse events. The latest Da Vinci Xi system has made total robotic rectal surgery feasible in single docking and single phase. With the new system, four arm total robotic rectal surgery may replace the hybrid technique of laparoscopic and robotic surgery for rectal malignancies. The learning curve for the new system appears to be shorter than anticipated. Early perioperative and oncological outcomes of total robotic rectal surgery with the new system are promising. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Full Robotic Colorectal Resections for Cancer Combined With Other Major Surgical Procedures: Early Experience With the da Vinci Xi.

    PubMed

    Morelli, Luca; Di Franco, Gregorio; Guadagni, Simone; Palmeri, Matteo; Gianardi, Desirée; Bianchini, Matteo; Moglia, Andrea; Ferrari, Vincenzo; Caprili, Giovanni; D'Isidoro, Cristiano; Melfi, Franca; Di Candio, Giulio; Mosca, Franco

    2017-08-01

    The da Vinci Xi has been developed to overcome some of the limitations of the previous platform, thereby increasing the acceptance of its use in robotic multiorgan surgery. Between January 2015 and October 2015, 10 patients with synchronous tumors of the colorectum and others abdominal organs underwent robotic combined resections with the da Vinci Xi. Trocar positions respected the Universal Port Placement Guidelines provided by Intuitive Surgical for "left lower quadrant," with trocars centered on the umbilical area, or shifted 2 to 3 cm to the right or to the left, depending on the type of combined surgical procedure. All procedures were completed with the full robotic technique. Simultaneous procedures in same quadrant or left quadrant and pelvis, or left/right and upper, were performed with a single docking/single targeting approach; in cases of left/right quadrant or right quadrant/pelvis, we performed a dual-targeting operation. No external collisions or problems related to trocar positions were noted. No patient experienced postoperative surgical complications and the mean hospital stay was 6 days. The high success rate of full robotic colorectal resection combined with other surgical interventions for synchronous tumors, suggest the efficacy of the da Vinci Xi in this setting.

  19. The LEONARDO-DA-VINCI pilot project "e-learning-assistant" - Situation-based learning in nursing education.

    PubMed

    Pfefferle, Petra Ina; Van den Stock, Etienne; Nauerth, Annette

    2010-07-01

    E-learning will play an important role in the training portfolio of students in higher and vocational education. Within the LEONARDO-DA-VINCI action programme transnational pilot projects were funded by the European Union, which aimed to improve the usage and quality of e-learning tools in education and professional training. The overall aim of the LEONARDO-DA-VINCI pilot project "e-learning-assistant" was to create new didactical and technical e-learning tools for Europe-wide use in nursing education. Based on a new situation-oriented learning approach, nursing teachers enrolled in the project were instructed to adapt, develop and implement e- and blended learning units. According to the training contents nursing modules were developed by teachers from partner institutions, implemented in the project centers and evaluated by students. The user-package "e-learning-assistant" as a product of the project includes two teacher training units, the authoring tool "synapse" to create situation-based e-learning units, a student's learning platform containing blended learning modules in nursing and an open sourced web-based communication centre. Copyright 2009 Elsevier Ltd. All rights reserved.

  20. Accuracy of a novel photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot

    NASA Astrophysics Data System (ADS)

    Gandhi, Neeraj; Kim, Sungmin; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2017-03-01

    Minimally invasive surgery carries the deadly risk of rupturing major blood vessels, such as the internal carotid arteries hidden by bone in endonasal transsphenoidal surgery. We propose a novel approach to surgical guidance that relies on photoacoustic-based vessel separation measurements to assess the extent of safety zones during these type of surgical procedures. This approach can be implemented with or without a robot or navigation system. To determine the accuracy of this approach, a custom phantom was designed and manufactured for modular placement of two 3.18-mm diameter vessel-mimicking targets separated by 10-20 mm. Photoacoustic images were acquired as the optical fiber was swept across the vessels in the absence and presence of teleoperation with a research da Vinci Surgical System. When the da Vinci was used, vessel positions were recorded based on the fiber position (calculated from the robot kinematics) that corresponded to an observed photoacoustic signal. In all cases, compounded photoacoustic data from a single sweep displayed the four vessel boundaries in one image. Amplitude- and coherence-based photoacoustic images were used to estimate vessel separations, resulting in 0.52-0.56 mm mean absolute errors, 0.66-0.71 mm root mean square errors, and 65-68% more accuracy compared to fiber position measurements obtained through the da Vinci robot kinematics. Results indicate that with further development, photoacoustic image-based measurements of anatomical landmarks could be a viable method for real-time path planning in multiple interventional photoacoustic applications.

  1. [A comparative study of Da Vinci robot system with video-assisted thoracoscopy in the surgical treatment of mediastinal lesions].

    PubMed

    Ding, Renquan; Tong, Xiangdong; Xu, Shiguang; Zhang, Dakun; Gao, Xin; Teng, Hong; Qu, Jiaqi; Wang, Shumin

    2014-07-20

    In recent years, Da Vinci robot system applied in the treatment of intrathoracic surgery mediastinal diseases become more mature. The aim of this study is to summarize the clinical data about mediastinal lesions of General Hospital of Shenyang Military Region in the past 4 years, then to analyze the treatment effect and promising applications of da Vinci robot system in the surgical treatment of mediastinal lesions. 203 cases of mediastinal lesions were collected from General Hospital of Shenyang Military Region between 2010 and 2013. These patients were divided into two groups da Vinci and video-assisted thoracoscopic surgery (VATS) according to the selection of the treatments. The time in surgery, intraoperative blood loss, postoperative drainage amount within three days after surgery, the period of bearing drainage tubes, hospital stays and hospitalization expense were then compared. All patients were successfully operated, the postoperative recovery is good and there is no perioperative death. The different of the time in surgery between two groups is Robots group 82 (20-320) min and thoracoscopic group 89 (35-360) min (P>0.05). The intraoperative blood loss between two groups is robot group 10 (1-100) mL and thoracoscopic group 50 (3-1,500) mL. The postoperative drainage amount within three days after surgery between two groups is robot group 215 (0-2,220) mL and thoracoscopic group 350 (50-1,810) mL. The period of bearing drainage tubes after surgery between two groups is robot group 3 (0-10) d and thoracoscopic group: 5 (1-18) d. The difference of hospital stays between two groups is robot group 7 (2-15) d and thoracoscopic group 9 (2-50) d. The hospitalization expense between two groups is robot group (18,983.6±4,461.2) RMB and thoracoscopic group (9,351.9±2,076.3) RMB (All P<0.001). The da Vinci robot system is safe and efficient in the treatment of mediastinal lesions compared with video-assisted thoracoscopic approach, even though its expense is higher.

  2. [Usefullness of the Da Vinci robot in urologic surgery].

    PubMed

    Iselin, C; Fateri, F; Caviezel, A; Schwartz, J; Hauser, J

    2007-12-05

    A telemanipulator for laparoscopic instruments is now available in the world of surgical robotics. This device has three distincts advantages over traditional laparoscopic surgery: it improves precision because of the many degrees of freedom of its instruments, and it offers 3-D vision so as better ergonomics for the surgeon. These characteristics are most useful for procedures that require delicate suturing in a focused operative field which may be difficult to reach. The Da Vinci robot has found its place in 2 domains of laparoscopic urologic surgery: radical prostatectomy and ureteral surgery. The cost of the robot, so as the price of its maintenance and instruments is high. This increases healthcare costs in comparison to open surgery, however not dramatically since patients stay less time in hospital and go back to work earlier.

  3. The Da Vinci Xi and robotic radical prostatectomy-an evolution in learning and technique.

    PubMed

    Goonewardene, S S; Cahill, D

    2017-06-01

    The da Vinci Xi robot has been introduced as the successor to the Si platform. The promise of the Xi is to open the door to new surgical procedures. For robotic-assisted radical prostatectomy (RARP)/pelvic surgery, the potential is better vision and longer instruments. How has the Xi impacted on operative and pathological parameters as indicators of surgical performance? This is a comparison of an initial series of 42 RARPs with the Xi system in 2015 with a series using the Si system immediately before Xi uptake in the same calendar year, and an Si series by the same surgeon synchronously as the Xi series using operative time, blood loss, and positive margins as surrogates of surgical performance. Subjectively and objectively, there is a learning curve to Xi uptake in longer operative times but no impact on T2 positive margins which are the most reflective single measure of RARP outcomes. Subjectively, the vision of the Xi is inferior to the Si system, and the integrated diathermy system and automated setup are quirky. All require experience to overcome. There is a learning curve to progress from the Si to Xi da Vinci surgical platforms, but this does not negatively impact the outcome.

  4. Leonardo da Vinci and Andreas Vesalius; the shoulder girdle and the spine, a comparison.

    PubMed

    Ganseman, Y; Broos, P

    2008-01-01

    Leonardo Da Vinci and Andreas Vesalius were two important renaissance persons; Vesalius was a surgeon-anatomist who delivered innovative work on the study of the human body, Leonardo da Vinci was an artist who delivered strikingly accurate and beautiful drawings on the human body. Below we compare both masters with regard to their knowledge of the working of the muscles, their method and system of dissection and their system and presentation of the drawings. The investigation consisted of a comparison between both anatomists, in particular concerning their study on the shoulder girdle and spine, by reviewing their original work as well as already existing literature on this subject. The investigation led to the conclusion that the drawings mentioned meant a change in history, and were of high quality, centuries ahead of their time. Both were anatomists, both were revolutionary, only one changed history at the moment itself, while the other changed history centuries later. Leonardo has made beautiful drawings that are at a match with the drawings of today or are even better. Vesalius set the start for medicine as a science as it is until this day. Their lives differed as strongly as their impact. In the light of their time, the achievement they made was extraordinary.

  5. Leonardo da Vinci (1452-1519)

    NASA Astrophysics Data System (ADS)

    Murdin, P.

    2000-11-01

    Painter, inventor and polymath, born in Vinci (near Empolia), Italy. Although astronomy does not figure large in Leonardo's works, he realized the possibility of constructing a telescope (`making glasses to see the Moon enlarged'). He suggested that `… in order to observe the nature of the planets, open the roof and bring the image of a single planet onto the base of a concave mirror. The image o...

  6. OCT structural examination of Madonna dei Fusi by Leonardo da Vinci

    NASA Astrophysics Data System (ADS)

    Targowski, Piotr; Iwanicka, Magdalena; Sylwestrzak, Marcin; Kaszewska, Ewa A.; Frosinini, Cecilia

    2013-05-01

    Madonna dei Fusi (`Madonna of the Yarnwider') is a spectacular example of Italian Renaissance painting, attributed to Leonardo da Vinci. The aim of this study is to give an account of past restoration procedures. The evidence of a former retouching campaign will be presented with cross-sectional images obtained non-invasively with Optical Coherence Tomography (OCT). Specifically, the locations of overpaintings/retouchings with respect to the original paint layer and secondary varnishes will be given. Additionally, the evidence of a former transfer of the pictorial layer to the new canvas support by detecting the presence of its structure incised into paint layer will be shown.

  7. Robotic da Vinci Xi-assisted nipple-sparing mastectomy: First clinical report.

    PubMed

    Sarfati, Benjamin; Honart, Jean-Francois; Leymarie, Nicolas; Rimareix, Francoise; Al Khashnam, Heba; Kolb, Frederic

    2018-05-01

    Nipple-sparing mastectomy (NSM) is increasingly popular for the treatment of selected breast cancers and prophylactic mastectomy. Surgical scarring and esthetic outcomes are important patient-related cosmetic considerations. Today, the concept of minimally invasive surgery has become popular, especially using robotic surgery. The authors report the first case of NSM using the latest version of the da Vinci Xi surgical system (Xi). The final incision used to remove the entire mammary gland was located behind the axillary line. In this position, hidden by the arm of the patient, the incision was not visible and was compatible with immediate breast reconstruction. © 2017 Wiley Periodicals, Inc.

  8. Leonardo da Vinci: the search for the soul.

    PubMed

    Del Maestro, R F

    1998-11-01

    The human race has always contemplated the question of the anatomical location of the soul. During the Renaissance the controversy crystallized into those individuals who supported the heart ("cardiocentric soul") and others who supported the brain ("cephalocentric soul") as the abode for this elusive entity. Leonardo da Vinci (1452-1519) joined a long list of other explorers in the "search for the soul." The method he used to resolve this anatomical problem involved the accumulation of information from ancient and contemporary sources, careful notetaking, discussions with acknowledged experts, and his own personal search for the truth. Leonardo used a myriad of innovative methods acquired from his knowledge of painting, sculpture, and architecture to define more clearly the site of the "senso comune"--the soul. In this review the author examines the sources of this ancient question, the knowledge base tapped by Leonardo for his personal search for the soul, and the views of key individuals who followed him.

  9. Structured training on the da Vinci Skills Simulator leads to improvement in technical performance of robotic novices.

    PubMed

    Walliczek-Dworschak, U; Mandapathil, M; Förtsch, A; Teymoortash, A; Dworschak, P; Werner, J A; Güldner, C

    2017-02-01

    The increasing use of minimally invasive techniques such as robotic-assisted devices raises the question of how to acquire robotic surgery skills. The da Vinci Skills Simulator has been demonstrated to be an effective training tool in previous reports. To date, little data are available on how to acquire proficiency through simulator training. We investigated the outcome of a structured training programme for robotic surgical skills by robotic novices. This prospective study was conducted from January to December 2013 using the da Vinci Skills Simulator. Twenty participants, all robotic novices, were enrolled in a 4-week training curriculum. After a brief introduction to the simulator system, three consecutive repetitions of five selected exercises (Match Board 1, 2, 3 and Ring and Rail 1, 2) were performed in a defined order on days 1, 8, 15 and 22. On day 22, one repetition of a previously unpractised more advanced module (Needle Targeting) was also performed. After completion of each study day, the overall performance, time to completion, economy in motion, instrument collisions, excessive instrument force, instruments out of view, master workspace range and number of drops were analysed. Comparing the first and final repetition, overall score and time needed to complete all exercises, economy of motion and instrument collisions were significantly improved in nearly all exercises. Regarding the new exercise, a positive training effect could be demonstrated. While its overall entry score was significantly higher, the time to completion and economy of motion were significantly lower than the scores on the first repetition of the previous 5 exercises. It could be shown that training on the da Vinci Skills Simulator led to an improvement in technical performance of robotic novices. With regard to a new exercise, the training had a positive effect on the technical performance. © 2016 John Wiley & Sons Ltd.

  10. Robotic-assisted single-port donor nephrectomy using the da Vinci single-site platform.

    PubMed

    LaMattina, John C; Alvarez-Casas, Josue; Lu, Irene; Powell, Jessica M; Sultan, Samuel; Phelan, Michael W; Barth, Rolf N

    2018-02-01

    Although single-port donor nephrectomy offers improved cosmetic outcomes, technical challenges have limited its application to selected centers. Our center has performed over 400 single-port donor nephrectomies. The da Vinci single-site robotic platform was utilized in an effort to overcome the steric, visualization, ergonomic, and other technical limitations associated with the single-port approach. Food and Drug Administration device exemption was obtained. Selection criteria for kidney donation included body mass index <35, left kidney donors, and ≤2 renal arteries. After colonic mobilization using standard single-port techniques, the robotic approach was utilized for ureteral complex and hilar dissection. Three cases were performed using the robotic single-site platform. Average total operative time was 262 ± 42 min including 82 ± 16 min of robotic use. Docking time took 20 ± 10 min. Blood loss averaged 77 ± 64 mL. No intraoperative complications occurred, and all procedures were completed with our standard laparoscopic single-port approach. This is the first clinical experience of robotic-assisted donor nephrectomy utilizing the da Vinci single-site platform. Our experience supported the safety of this approach but found that the technology added cost and complexity without tangible benefit. Development of articulating instruments, energy, and stapling devices will be necessary for increased application of robotic single-site surgery for donor nephrectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Development of a Classification Scheme for Examining Adverse Events Associated with Medical Devices, Specifically the DaVinci Surgical System as Reported in the FDA MAUDE Database.

    PubMed

    Gupta, Priyanka; Schomburg, John; Krishna, Suprita; Adejoro, Oluwakayode; Wang, Qi; Marsh, Benjamin; Nguyen, Andrew; Genere, Juan Reyes; Self, Patrick; Lund, Erik; Konety, Badrinath R

    2017-01-01

    To examine the Manufacturer and User Facility Device Experience Database (MAUDE) database to capture adverse events experienced with the Da Vinci Surgical System. In addition, to design a standardized classification system to categorize the complications and machine failures associated with the device. Overall, 1,057,000 DaVinci procedures were performed in the United States between 2009 and 2012. Currently, no system exists for classifying and comparing device-related errors and complications with which to evaluate adverse events associated with the Da Vinci Surgical System. The MAUDE database was queried for events reports related to the DaVinci Surgical System between the years 2009 and 2012. A classification system was developed and tested among 14 robotic surgeons to associate a level of severity with each event and its relationship to the DaVinci Surgical System. Events were then classified according to this system and examined by using Chi-square analysis. Two thousand eight hundred thirty-seven events were identified, of which 34% were obstetrics and gynecology (Ob/Gyn); 19%, urology; 11%, other; and 36%, not specified. Our classification system had moderate agreement with a Kappa score of 0.52. Using our classification system, we identified 75% of the events as mild, 18% as moderate, 4% as severe, and 3% as life threatening or resulting in death. Seventy-seven percent were classified as definitely related to the device, 15% as possibly related, and 8% as not related. Urology procedures compared with Ob/Gyn were associated with more severe events (38% vs 26%, p < 0.0001). Energy instruments were associated with less severe events compared with the surgical system (8% vs 87%, p < 0.0001). Events that were definitely associated with the device tended to be less severe (81% vs 19%, p < 0.0001). Our classification system is a valid tool with moderate inter-rater agreement that can be used to better understand device-related adverse events. The

  12. Michelangelo in Florence, Leonardo in Vinci.

    ERIC Educational Resources Information Center

    Herberholz, Barbara

    2003-01-01

    Provides background information on the lives and works of Michelangelo and Leonardo da Vinci. Focuses on the artwork of the artists and the museums where their work is displayed. Includes museum photographs of their work. (CMK)

  13. Robot-assisted total mesorectal excision for rectal cancer: case-matched comparison of short-term surgical and functional outcomes between the da Vinci Xi and Si.

    PubMed

    Morelli, Luca; Di Franco, Gregorio; Guadagni, Simone; Rossi, Leonardo; Palmeri, Matteo; Furbetta, Niccolò; Gianardi, Desirée; Bianchini, Matteo; Caprili, Giovanni; D'Isidoro, Cristiano; Mosca, Franco; Moglia, Andrea; Cuschieri, Alfred

    2018-02-01

    Robotic rectal resection with da Vinci Si has some technical limitations, which could be overcome by the new da Vinci Xi. We compare short-term surgical and functional outcomes following robotic rectal resection with total mesorectal excision for cancer, with the da Vinci Xi (Xi-RobTME group) and the da Vinci Si (Si-RobTME group). The first consecutive 30 Xi-RobTME were compared with a Si-RobTME control group of 30 patients, selected using a one-to-one case-matched methodology from our prospectively collected Institutional database, comprising all cases performed between April 2010 and September 2016 by a single surgeon. Perioperative outcomes were compared. The impact of minimally invasive TME on autonomic function and quality of life was analyzed with specific questionnaires. The docking and overall operative time were shorter in the Xi-RobTME group (p < 0.001 and p < 0.05 respectively). The mean differences of overall operative time and docking time were -33.8 min (95% CI -5.1 to -64.5) and -6 min (95% CI -4.1 to -7.9), respectively. A fully-robotic approach with complete splenic flexure mobilization was used in 30/30 (100%) of the Xi-RobTME cases and in 7/30 (23%) of the Si-RobTME group (p < 0.001). The hybrid approach in males and patients with BMI > 25 kg/m 2 was necessary in ten patients (45 vs. 0%, p < 0.001) and in six patients (37 vs. 0%, p < 0.05), in the Si-RobTME and Xi-RobTME groups, respectively. There were no differences in conversion rate, mean hospital stay, pathological data, and in functional outcomes between the two groups before and at 1 year after surgery. The technical advantages offered by the da Vinci Xi seem to be mainly associated with a shorter docking and operative time and with superior ability to perform a fully-robotic approach. Clinical and functional outcomes seem not to be improved, with the introduction of the new Xi platform.

  14. Initial experience of Da Vinci robotic thoracic surgery at the First Affiliated Hospital of Zhejiang University

    PubMed Central

    He, Zhehao; Zeng, Liping; Zhang, Chong; Wang, Luming; Wang, Zhitian; Rustam, Azmat; Du, Chengli; Lv, Wang

    2017-01-01

    Robot-assisted thoracic surgery (RATS) is a relatively new but rapidly adopted technique, pioneered by the urological and gynecological departments. The primary objective of this study is to present the current status, a series of improvement and innovation of Da Vinci robotic surgery in the Department of Thoracic Surgery at First Affiliated Hospital of Zhejiang University. In addition, we discuss the prospect of robotic surgical technology. PMID:29302429

  15. Educating in the Design and Construction of Built Environments Accessible to Disabled People: The Leonardo da Vinci AWARD Project

    ERIC Educational Resources Information Center

    Frattari, Antonio; Dalpra, Michela; Bernardi, Fabio

    2013-01-01

    An interdisciplinary partnership within an European Leonardo da Vinci project has developed a new approach aimed at educating secondary school students in the creation of built environments accessible to disabled people and at sensitizing them towards the inclusion of people with disabilities in all realms of social life. The AWARD (Accessible…

  16. [The anatomy of a reduced skull model--visualisation of Leonardo da Vinci's anthropology].

    PubMed

    Ahner, E

    2008-04-02

    The article focuses on a rare example of a miniature skull of unknown origin. The profoundness of the anatomical details, conjoint with outstanding virtuosity, reminds of Leonardo da Vinci's anatomical skull studies and asks for additional interpretation beside the emblematic "memento mori"-character. Following the miscellaneous topics of his skull studies an anatomical-anthropological interpretation is proposed. For such a project the mergence of anthropology, history of medicine and history of art was mandatory. Concerning some discrepancies within the anatomical realism, the depiction of a pathology is discussed and beyond the visualisation of a historic concept of brain function.

  17. Virtual Mobility in Reality: A Study of the Use of ICT in Finnish Leonardo da Vinci Mobility Projects.

    ERIC Educational Resources Information Center

    Valjus, Sonja

    An e-mail survey and interviews collected data on use of information and communications technology (ICT) in Finnish Leonardo da Vinci mobility projects from 2000-02. Findings showed that the most common ICT tools used were e-mail, digital tools, and the World Wide Web; ICT was used during all project phases; the most common problems concerned…

  18. Urodynamics in the anatomical work of Leonardo da Vinci (1452-1519).

    PubMed

    Schultheiss, D; Grünewald, V; Jonas, U

    1999-06-01

    Leonardo da Vinci (1452-1519) incorporates the symbiosis of art and medicine and can be addressed as the founder of medical illustration in the time of the Renaissance. His anatomy studies were not published in his time, which explains why Leonardo's outstanding knowledge of anatomy, physiology, and medicine had no impact on his scientific contemporaries and is therefore primarily of retrospective importance in the history of medicine. The collection of anatomical illustrations remained unknown until their rediscovery in the eighteenth century and their wide publication at the beginning of our century. This article systematically reviews Leonardo's genitourinary drawings with regard to urodynamic aspects of the upper and lower urinary tract, highlighting topics such as vesicoureteral reflux and urinary sphincter mechanisms.

  19. Error reporting from the da Vinci surgical system in robotic surgery: A Canadian multispecialty experience at a single academic centre

    PubMed Central

    Rajih, Emad; Tholomier, Côme; Cormier, Beatrice; Samouëlian, Vanessa; Warkus, Thomas; Liberman, Moishe; Widmer, Hugues; Lattouf, Jean-Baptiste; Alenizi, Abdullah M.; Meskawi, Malek; Valdivieso, Roger; Hueber, Pierre-Alain; Karakewicz, Pierre I.; El-Hakim, Assaad; Zorn, Kevin C.

    2017-01-01

    Introduction The goal of the study is to evaluate and report on the third-generation da Vinci surgical (Si) system malfunctions. Methods A total of 1228 robotic surgeries were performed between January 2012 and December 2015 at our academic centre. All cases were performed by using a single, dual console, four-arm, da Vinci Si robot system. The three specialties included urology, gynecology, and thoracic surgery. Studied outcomes included the robotic surgical error types, immediate consequences, and operative side effects. Error rate trend with time was also examined. Results Overall robotic malfunctions were documented on the da Vinci Si systems event log in 4.97% (61/1228) of the cases. The most common error was related to pressure sensors in the robotic arms indicating out of limit output. This recoverable fault was noted in 2.04% (25/1228) of cases. Other errors included unrecoverable electronic communication-related in 1.06% (13/1228) of cases, failed encoder error in 0.57% (7/1228), illuminator-related in 0.33% (4/1228), faulty switch in 0.24% (3/1228), battery-related failures in 0.24% (3/1228), and software/hardware error in 0.08% (1/1228) of cases. Surgical delay was reported only in one patient. No conversion to either open or laparoscopic occurred secondary to robotic malfunctions. In 2015, the incidence of robotic error rose to 1.71% (21/1228) from 0.81% (10/1228) in 2014. Conclusions Robotic malfunction is not infrequent in the current era of robotic surgery in various surgical subspecialties, but rarely consequential. Their seldom occurrence does not seem to affect patient safety or surgical outcome. PMID:28503234

  20. Error reporting from the da Vinci surgical system in robotic surgery: A Canadian multispecialty experience at a single academic centre.

    PubMed

    Rajih, Emad; Tholomier, Côme; Cormier, Beatrice; Samouëlian, Vanessa; Warkus, Thomas; Liberman, Moishe; Widmer, Hugues; Lattouf, Jean-Baptiste; Alenizi, Abdullah M; Meskawi, Malek; Valdivieso, Roger; Hueber, Pierre-Alain; Karakewicz, Pierre I; El-Hakim, Assaad; Zorn, Kevin C

    2017-05-01

    The goal of the study is to evaluate and report on the third-generation da Vinci surgical (Si) system malfunctions. A total of 1228 robotic surgeries were performed between January 2012 and December 2015 at our academic centre. All cases were performed by using a single, dual console, four-arm, da Vinci Si robot system. The three specialties included urology, gynecology, and thoracic surgery. Studied outcomes included the robotic surgical error types, immediate consequences, and operative side effects. Error rate trend with time was also examined. Overall robotic malfunctions were documented on the da Vinci Si systems event log in 4.97% (61/1228) of the cases. The most common error was related to pressure sensors in the robotic arms indicating out of limit output. This recoverable fault was noted in 2.04% (25/1228) of cases. Other errors included unrecoverable electronic communication-related in 1.06% (13/1228) of cases, failed encoder error in 0.57% (7/1228), illuminator-related in 0.33% (4/1228), faulty switch in 0.24% (3/1228), battery-related failures in 0.24% (3/1228), and software/hardware error in 0.08% (1/1228) of cases. Surgical delay was reported only in one patient. No conversion to either open or laparoscopic occurred secondary to robotic malfunctions. In 2015, the incidence of robotic error rose to 1.71% (21/1228) from 0.81% (10/1228) in 2014. Robotic malfunction is not infrequent in the current era of robotic surgery in various surgical subspecialties, but rarely consequential. Their seldom occurrence does not seem to affect patient safety or surgical outcome.

  1. Surgical treatment of gastroesophageal reflux disease and upside-down stomach using the Da Vinci robotic system. A prospective study.

    PubMed

    Hartmann, Jens; Jacobi, Christoph A; Menenakos, Charalambos; Ismail, Mahmoud; Braumann, Chris

    2008-03-01

    So far, the impact of telematic surgical approach in Gastroesophageal Reflux Disease (GERD) is still obscure. In this prospective study, we analyzed the Da Vinci Intuitive Surgical robotic system for antireflux surgery. In April 2003, we set up a pilot study to evaluate the efficacy of laparoscopic telerobotic surgery using the three-arm Da Vinci system. Optimal trocar positions, operating and setup times, conversion rate, intraoperative complications, and perioperative morbidity, as well as mortality rate, were analyzed. The median age was 53 years (range 25-74) in 118 patients (52 female/66 male). In 17 patients, an upside-down stomach- and in 101 GERD was surgical indication. The median operating time has been reduced from 105 min to 91 min after 40 procedures and setup time from 24.5 min to 10.4 min after 10 procedures. The system is safe and it seems to be superior to traditional laparoscopy during dissection in the esophageal hiatus region. This compensates long setup- and operating times. Disadvantages are the high costs, the time to master the setup/system and the necessity of exact trocar positioning.

  2. Performance of da Vinci Stapler during robotic-assisted right colectomy with intracorporeal anastomosis.

    PubMed

    Johnson, Craig S; Kassir, Andrew; Marx, Daryl S; Soliman, Mark K

    2018-05-30

    Applications for surgical staplers continue to grow, due to the increase in minimally invasive surgical approaches, and range from vessel ligation to tissue transection and anastomoses. Complications associated with stapled tissue, such as bleeding or leaks, continue to be a concern for surgeons, as both can be associated with prolonged operative times and can contribute to postoperative morbidity and mortality. The goal of this retrospective study was to evaluate the performance of the da Vinci ® Xi EndoWrist ® Stapler 45 with SmartClamp™ technology during robotic-assisted right colectomy with intracorporeal anastomosis. We reviewed 113 consecutive cases from four medical centers. Preclinical diagnoses were inflammatory bowel disease (IBD) (n = 5), benign bowel disease (n = 77), and malignant bowel disease (n = 31). No anastomotic leaks occurred; one event of anastomotic bleeding (0.88%) resolved without surgical intervention. Overall, there were 643 clamp attempts (5.7 attempts per case), and 570 fires (5.0 fires per case). SmartClamp™ occurrences happened in approximately one out of three cases, with the highest proportion of occurrences in the IBD group (2.0 occurrences per case). The most commonly fired reload was blue (1.5 mm closed height) with 4.1 blue reloads fired per case overall. No incomplete fires occurred during the procedures. The study data demonstrate the performance of the da Vinci Xi EndoWrist ® Stapler 45 as used in right colon resection with intracorporeal anastomosis. The collection and analysis of these data provide surgeons with information related to stapler firings, which were not previously available; as such, this analysis may lead to deductions that are useful for intraoperative decision-making and clinical outcomes.

  3. From Leonardo to da Vinci: the history of robot-assisted surgery in urology.

    PubMed

    Yates, David R; Vaessen, Christophe; Roupret, Morgan

    2011-12-01

    What's known on the subject? and What does the study add? Numerous urological procedures can now be performed with robotic assistance. Though not definitely proven to be superior to conventional laparoscopy or traditional open surgery in the setting of a randomised trial, in experienced centres robot-assisted surgery allows for excellent surgical outcomes and is a valuable tool to augment modern surgical practice. Our review highlights the depth of history that underpins the robotic surgical platform we utilise today, whilst also detailing the current place of robot-assisted surgery in urology in 2011. The evolution of robots in general and as platforms to augment surgical practice is an intriguing story that spans cultures, continents and centuries. A timeline from Yan Shi (1023-957 bc), Archytas of Tarentum (400 bc), Aristotle (322 bc), Heron of Alexandria (10-70 ad), Leonardo da Vinci (1495), the Industrial Revolution (1790), 'telepresence' (1950) and to the da Vinci(®) Surgical System (1999), shows the incredible depth of history and development that underpins the modern surgical robot we use to treat our patients. Robot-assisted surgery is now well-established in Urology and although not currently regarded as a 'gold standard' approach for any urological procedure, it is being increasingly used for index operations of the prostate, kidney and bladder. We perceive that robotic evolution will continue infinitely, securing the place of robots in the history of Urological surgery. Herein, we detail the history of robots in general, in surgery and in Urology, highlighting the current place of robot-assisted surgery in radical prostatectomy, partial nephrectomy, pyeloplasty and radical cystectomy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  4. Use of Simulation in Nursing Education: Initial Experiences on a European Union Lifelong Learning Programme--Leonardo Da Vinci Project

    ERIC Educational Resources Information Center

    Terzioglu, Fusun; Tuna, Zahide; Duygulu, Sergul; Boztepe, Handan; Kapucu, Sevgisun; Ozdemir, Leyla; Akdemir, Nuran; Kocoglu, Deniz; Alinier, Guillaume; Festini, Filippo

    2013-01-01

    Aim: The aim of this paper is to share the initial experiences on a European Union (EU) Lifelong Learning Programme Leonardo Da Vinci Transfer of Innovation Project related to the use of simulation-based learning with nursing students from Turkey. The project started at the end of the 2010 involving 7 partners from 3 different countries including…

  5. Sine ars scientia nihil est: Leonardo da Vinci and beyond.

    PubMed

    Kickhöfel, Eduardo H P

    2009-01-01

    The aim of this article is to reflect on the relationship between art and science so far as it concerns a symposium on neurosciences. We undertake a historical overview of that relationship, paying particular attention to the sui generis case of Leonardo da Vinci, who very often is regarded as the man who worked on art and science with equal ease. We then explain why his idea of merging these two forms of knowledge failed, considering the clear-cut distinction between art and science in his time. With this clarification, we explore the matter today. We look at Raphael's The Transfiguration, in which the representation of the possessed boy is seen by neuroscientists as indicative of an epileptic seizure. We also look at the ideas of neuroscientists Semir Zeki and Vilayanur Ramachandran, who study particular aspects of brain function and suggest a new merging of art and science.

  6. [Regarding the Manuscript D " Dell' occhio " of Leonardo da Vinci].

    PubMed

    Heitz, Robert F

    2009-01-01

    Leonardo da Vinci's Manuscript D consists of five double pages sheets, which, folded in two, comprise ten folios. This document, in the old Tuscan dialect and mirror writing, reveals the ideas of Leonardo on the anatomy of the eye in relation to the formation of images and visual perception. Leonardo explains in particular the behavior of the rays in the eye in terms of refraction and reflection, and is very mechanistic in his conception of the eye and of the visual process. The most significant innovations found in these folios are the concept of the eye as a camera obscura and the intersection of light rays in the interior of the eye. His texts nevertheless show hesitation, doubts and a troubled confusion, reflecting the ideas and uncertainties of his era. He did not share his results in his lifetime, despite both printing and etching being readily available to him.

  7. [Project Leonardo-da-Vinci for better nursing care].

    PubMed

    Gábor, Katalin; Csanádi, Lajosné; Helembai, Kornélia; Szögi, Zoltánné; Tulkán, Ibolya; Unginé, Kántor Katalin

    2002-08-18

    The aim of the present paper is to inform physicians about the work completed by nurses and professors of baccalaureat nurses in the framework of Leonardo da Vinci project, organised and sponsored by the European Union. The goal of the project was to increase the effectiveness of chief nurses throughout their further training programme in the field of management. The team of Szeged chose the human resource management, since in this field is possible to achieve the greatest improvement with the smallest financial investment. We measured the fluctuations and the absentees of the nurses, the changes in the degree of education, the nurse' and patient' satisfaction at the beginning and at the end of the period studied. Except the patient's satisfaction all the other parameters improved by the end of tested period. The project provided a unique possibility to compare the state of the Hungarian nursing with that of the countries belonging to the European Union, to exchange the experience and to learn some new methods. In the framework of this project a book of two volumes was prepared containing the suggestions of EU. This book is widely available in English and in French.

  8. Robot-Assisted Laparoendoscopic Single-Site Partial Nephrectomy With the Novel Da Vinci Single-Site Platform: Initial Experience

    PubMed Central

    Komninos, Christos; Tuliao, Patrick; Kim, Dae Keun; Choi, Young Deuk; Chung, Byung Ha

    2014-01-01

    Purpose To report our initial clinical cases of robotic laparoendoscopic single-site (R-LESS) partial nephrectomy (PN) performed with the use of the novel Da Vinci R-LESS platform. Materials and Methods Three patients underwent R-LESS PN from November 2013 through February 2014. Perioperative and postoperative outcomes were collected and intraoperative difficulties were noted. Results Operative time and estimated blood loss volume ranged between 100 and 110 minutes and between 50 and 500 mL, respectively. None of the patients was transfused. All cases were completed with the off-clamp technique, whereas one case required conversion to the conventional (multiport) approach because of difficulty in creating the appropriate scope for safe tumor resection. No major postoperative complications occurred, and all tumors were resected in safe margins. Length of hospital stay ranged between 3 and 7 days. The lack of EndoWrist movements, the external collisions, and the bed assistant's limited working space were noticed to be the main drawbacks of this surgical method. Conclusions Our initial experience with R-LESS PN with the novel Da Vinci platform shows that even though the procedure is feasible, it should be applied in only appropriately selected patients. However, further improvement is needed to overcome the existing limitations. PMID:24955221

  9. [A Paired Case Controlled Study Comparing the Short-term Outcomes of Da Vinci RATS and VATS Approach for Non-small Cell Lung Cancer].

    PubMed

    Dai, Feng; Xu, Shiguang; Xu, Wei; Ding, Renquan; Liu, Bo; Meng, Hao; Kang, Yunteng; Meng, Xiangrui; Lin, Jie; Wang, Shumin

    2018-03-20

    Da Vinci Surgical System is one of the greatest inventions of the 20th century, which represents the development direction of the precise minimally invasive surgical techniques, the aim of this study was to comparing the short-term outcomes between da Vinci robot-assisted lobectomy and video-assisted thoracic surgery (VATS) lobectomy for non-small cell lung cancer. 45 pairs of non-small cell lung cancer patients underwent pulmonary lobectomy with da Vinci Robotic assisted thoracoscopic (RATS) and VATS approach during the same period from January 2014 to January 2017. The operative time, estimated blood loss (EBL), total number and total groups of dissected lymph nodes, postoperative duration of drainage, the first day volume of drainage, total volume of drainage were compared. No perioperative death and convertion to thoracotomy occured in both groups. There were significant difference between RATS group and VATS group in EBL [(50.30±32.33) mL vs (208.60±132.63) mL], the first day volume of drainage [(275.00±145.42) mL vs (347.60±125.80) mL], the dissected total number [(22.67±9.67) vs (15.51±5.41)] and total team [(6.31±1.43) vs (4.91±1.04)] of lymph node. There were no significant difference in other outcomes. RATS is safe and effective and took better short-outcomes than VATS in non-small cell lung cancer.

  10. Microbiological Analysis of Surfaces of Leonardo Da Vinci's Atlantic Codex: Biodeterioration Risk.

    PubMed

    Tarsitani, Gianfranco; Moroni, Catia; Cappitelli, Francesca; Pasquariello, Giovanna; Maggi, Oriana

    2014-01-01

    Following the discovery of discoloration on some pages of the Atlantic Codex (AC) of Leonardo da Vinci kept in the Biblioteca Ambrosiana in Milan, some investigations have been carried out to verify the presence of microorganisms, such as bacteria and fungi. To verify the presence of microorganisms a noninvasive method of sampling has been used that was efficient and allowed us to highlight the microbial facies of the material that was examined using conventional microbiological techniques. The microclimatic conditions in the storage room as well as the water content of the volume were also assessed. The combined observations allowed the conclusion that the discoloration of suspected biological origin on some pages of AC is not related to the presence or current attack of microbial agents.

  11. Microbiological Analysis of Surfaces of Leonardo Da Vinci's Atlantic Codex: Biodeterioration Risk

    PubMed Central

    Moroni, Catia; Pasquariello, Giovanna; Maggi, Oriana

    2014-01-01

    Following the discovery of discoloration on some pages of the Atlantic Codex (AC) of Leonardo da Vinci kept in the Biblioteca Ambrosiana in Milan, some investigations have been carried out to verify the presence of microorganisms, such as bacteria and fungi. To verify the presence of microorganisms a noninvasive method of sampling has been used that was efficient and allowed us to highlight the microbial facies of the material that was examined using conventional microbiological techniques. The microclimatic conditions in the storage room as well as the water content of the volume were also assessed. The combined observations allowed the conclusion that the discoloration of suspected biological origin on some pages of AC is not related to the presence or current attack of microbial agents. PMID:25574171

  12. Comparative analysis of the functionality of simulators of the da Vinci surgical robot.

    PubMed

    Smith, Roger; Truong, Mireille; Perez, Manuela

    2015-04-01

    The implementation of robotic technology in minimally invasive surgery has led to the need to develop more efficient and effective training methods, as well as assessment and skill maintenance tools for surgical education. Multiple simulators and procedures are available for educational and training purposes. A need for comparative evaluations of these simulators exists to aid users in selecting an appropriate device for their purposes. We conducted an objective review and comparison of the design and capabilities of all dedicated simulators of the da Vinci robot, the da Vinci Skill Simulator (DVSS) (Intuitive Surgical Inc., Sunnyvale, CA, USA), dV-Trainer (dVT) (Mimic Technologies Inc., Seattle, WA, USA), and Robotic Surgery Simulator (RoSS) (Simulated Surgical Skills, LLC, Williamsville, NY, USA). This provides base specifications of the hardware and software, with an emphasis on the training capabilities of each system. Each simulator contains a large number of training exercises, DVSS = 40, dVT = 65, and RoSS = 52 for skills development. All three offer 3D visual images but use different display technologies. The DVSS leverages the real robotic surgeon's console to provide visualization, hand controls, and foot pedals. The dVT and RoSS created simulated versions of all of these control systems. They include systems management services which allow instructors to collect, export, and analyze the scores of students using the simulators. This study is the first to provide comparative information of the three simulators functional capabilities with an emphasis on their educational skills. They offer unique advantages and capabilities in training robotic surgeons. Each device has been the subject of multiple validation experiments which have been published in the literature. But those do not provide specific details on the capabilities of the simulators which are necessary for an understanding sufficient to select the one best suited for an organization's needs.

  13. [The art of Leonardo Da Vinci as a resource to science and the ideal of nursing care].

    PubMed

    Nascimento, Maria Aparecida de Luca; de Brito, Isabela Jorge; Dehoul, Marcelo da Silva

    2003-01-01

    Theoretical reflection whose goal is to demonstrate the art a nursing team is required to show in order to perform a technical procedure for transfer of solutions from a normal vial to a microdrops vial, based on Leonardo Da Vinci's theoretical referential, inspired by his work called "Vitruvian Man", so that body harmony is kept. The authors emphasize its relationship to nursing care, viewing it from its broadest sense, and its own motto--"Science, Art and Ideal".

  14. da Vinci skills simulator for assessing learning curve and criterion-based training of robotic basic skills.

    PubMed

    Brinkman, Willem M; Luursema, Jan-Maarten; Kengen, Bas; Schout, Barbara M A; Witjes, J Alfred; Bekkers, Ruud L

    2013-03-01

    To answer 2 research questions: what are the learning curve patterns of novices on the da Vinci skills simulator parameters and what parameters are appropriate for criterion-based robotic training. A total of 17 novices completed 2 simulator sessions within 3 days. Each training session consisted of a warming-up exercise, followed by 5 repetitions of the "ring and rail II" task. Expert participants (n = 3) performed a warming-up exercise and 3 repetitions of the "ring and rail II" task on 1 day. We analyzed all 9 parameters of the simulator. Significant learning occurred on 5 parameters: overall score, time to complete, instrument collision, instruments out of view, and critical errors within 1-10 repetitions (P <.05). Economy of motion and excessive instrument force only showed improvement within the first 5 repetitions. No significant learning on the parameter drops and master workspace range was found. Using the expert overall performance score (n = 3) as a criterion (overall score 90%), 9 of 17 novice participants met the criterion within 10 repetitions. Most parameters showed that basic robotic skills are learned relatively quickly using the da Vinci skills simulator, but that 10 repetitions were not sufficient for most novices to reach an expert level. Some parameters seemed inappropriate for expert-based criterion training because either no learning occurred or the novice performance was equal to expert performance. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Leonardo da Vinci meets celiac disease.

    PubMed

    Zanchi, Chiara; Ventura, Giovanna; Di Leo, Grazia; Orzes, Nicoletta; Ronfani, Luca; Not, Tarcisio; Ventura, Alessandro

    2013-02-01

    Leonardo da Vinci's face symmetry derives from 3 equal craniofacial segments: trichion-nasion (tn), which represents the superior third of the face, nasion-subnasal (ns) that is the medium third of the face, and subnasal-gnathion (sg) that is the length of the lower third of the face. It has been reported that adult subjects with celiac disease (CD) can be identified on the basis of a greater extension of the forehead in comparison to the medium third of the face, with a high tn/ns ratio. The aim of the present study was to investigate the correlation between facial asymmetry and CD in childhood and adulthood. We studied 126 biopsy-proven patients with CD (76 children and 50 adults) and 102 healthy controls (43 children and 59 adults). Their faces were photographed; the pictures were edited using a software program to calculate the facial segments. The tn length was significantly different between adult celiac and adult controls (7.43 ± 1.46 cm vs 6.38 ± 1.73 cm, P = 0.001). The cutoff of 6.5 cm tn, derived from receiver operating characteristic curve analysis, identified 43 of 50 patients (sensitivity 86%), but 34 of 59 controls were positive (specificity 54.2%). The positive predictive value was 56%; however, the tn/ns ratio was not significantly different between celiacs and controls. Neither the tn length nor the tn/ns ratio in celiacs correlated to the time of gluten exposure. Adults, but not children, with celiac disease show a forehead extension significantly greater than controls, but this test's specificity appears too low to be used in the screening of CD.

  16. Port positioning and docking for single-stage totally robotic dissection for rectal cancer surgery with the Si and Xi Da Vinci Surgical System.

    PubMed

    Toh, James Wei Tatt; Kim, Seon-Hahn

    2017-11-04

    We have previously reported our technique of single-docking totally robotic dissection for rectal cancer surgery using the Da Vinci ® Si Surgical System in 2009. However, we have since optimised our port placement for the Si system and have developed a novel configuration of port placement and docking for the Da Vinci ® Xi Surgical System. We have performed over 700 cases using this technique with the Si system and have used our Xi technique since 2016 for totally robotic dissection for rectal cancer. We have kept the configuration of port placements for both the Xi and Si system as similar as possible, with the priorities to avoid arm collisions as well as to provide a workable port configuration of two left-handed instruments and one right-handed instrument. To date, there have had no major complications or arm collisions related to this technique of docking, port positioning and instrument placement.

  17. The experience of totally endoscopic coronary bypass grafting with the robotic system «Da Vinci» in Russia

    NASA Astrophysics Data System (ADS)

    Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.

    2015-11-01

    A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.

  18. Da Vinci robot error and failure rates: single institution experience on a single three-arm robot unit of more than 700 consecutive robot-assisted laparoscopic radical prostatectomies.

    PubMed

    Zorn, Kevin C; Gofrit, Ofer N; Orvieto, Marcelo A; Mikhail, Albert A; Galocy, R Matthew; Shalhav, Arieh L; Zagaja, Gregory P

    2007-11-01

    Previous reports have suggested that a 2% to 5% device failure rate (FR) be quoted when counseling patients about robot-assisted laparoscopic radical prostatectomy (RLRP). We sought to evaluate our FR on the da Vinci system. Since February 2003, more than 800 RLRPs have been performed at our institution using a single three-armed robotic unit. A prospective database was analyzed to determine the device FR and whether it resulted in case abortion or open conversion. Intuitive Surgical Systems provided data concerning the system's performance, including its fault rate. Error messages were classified as recoverable and non-recoverable faults. Between February 2003 and November 2006, 725 RLRP cases were available for evaluation. There were no intraoperative device failures that resulted in a case conversion. Technical errors resulting in surgeon handicap occurred in 3 cases (0.4%). Four patients (0.5%) had their procedures aborted secondary to system failure at initial set-up prior to patient entrance to the operating room. Data analysis retrieved from the da Vinci console reported on a total of 807 procedures since 2003. Only 4 cases (0.4%) were reported from the Intuitive Surgical database to result in either an aborted or a converted case, which compares favorably with our results. Since the last computer system upgrade (September 2005), the mean recoverable and non-recoverable fault rates per procedure were 0.21 and 0.05, respectively. For all the advanced features the da Vinci system offers, it is surprisingly reliable. Throughout our RLRP experience, device failure resulted in case conversion, procedure abortion, and surgeon handicap in 0, 0.5%, and 0.4% of procedures, respectively. As such, a lowered device FR of 0.5% should be used when counseling patients undergoing RLRP. To avoid futile general anesthesia, a policy should be enforced to ensure that the da Vinci system is completely set up before the patient enters the operating room.

  19. A laminar cortical model of stereopsis and 3D surface perception: closure and da Vinci stereopsis.

    PubMed

    Cao, Yongqiang; Grossberg, Stephen

    2005-01-01

    A laminar cortical model of stereopsis and 3D surface perception is developed and simulated. The model describes how monocular and binocular oriented filtering interact with later stages of 3D boundary formation and surface filling-in in the LGN and cortical areas V1, V2, and V4. It proposes how interactions between layers 4, 3B, and 2/3 in V1 and V2 contribute to stereopsis, and how binocular and monocular information combine to form 3D boundary and surface representations. The model includes two main new developments: (1) It clarifies how surface-to-boundary feedback from V2 thin stripes to pale stripes helps to explain data about stereopsis. This feedback has previously been used to explain data about 3D figure-ground perception. (2) It proposes that the binocular false match problem is subsumed under the Gestalt grouping problem. In particular, the disparity filter, which helps to solve the correspondence problem by eliminating false matches, is realized using inhibitory interneurons as part of the perceptual grouping process by horizontal connections in layer 2/3 of cortical area V2. The enhanced model explains all the psychophysical data previously simulated by Grossberg and Howe (2003), such as contrast variations of dichoptic masking and the correspondence problem, the effect of interocular contrast differences on stereoacuity, Panum's limiting case, the Venetian blind illusion, stereopsis with polarity-reversed stereograms, and da Vinci stereopsis. It also explains psychophysical data about perceptual closure and variations of da Vinci stereopsis that previous models cannot yet explain.

  20. Bell's palsy: the answer to the riddle of Leonardo da Vinci's 'Mona Lisa'.

    PubMed

    Maloney, W J

    2011-05-01

    The smile of the famed portrait 'The Mona Lisa' has perplexed both art historians and researchers for the past 500 years. There has been a multitude of theories expounded to explain the nature of the model's enigmatic smile. The origin of the model's wry smile can be demonstrated through a careful analysis of both documented facts concerning the portrait--some gathered only recently through the use of modern technology--and a knowledge of the clinical presentation of Bell's palsy. Bell's palsy is more prevalent in women who are either pregnant or who have recently given birth. This paper postulates that the smile of the portrait's model was due to Leonardo da Vinci's anatomically precise representation of a new mother affected by Bell's palsy subsequent to her recent pregnancy.

  1. Media Images Abbott and Costello Meet the End of the World: Who Is the Enemy in "The Da Vinci Code" and "An Inconvenient Truth?"

    ERIC Educational Resources Information Center

    Beck, Bernard

    2007-01-01

    Popular culture requires readily identifiable villains. Subcultural groups often serve this role, creating controversies. Controversies based on religion are especially bitter. As a rule, religion in the movies is inoffensively sentimental, but "The Da Vinci Code" is both popular and provocative, treading on the dangerous ground of Jesus's…

  2. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    PubMed

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  3. A prospective, single-arm study on the use of the da Vinci® Table Motion with the Trumpf TS7000dV operating table.

    PubMed

    Morelli, Luca; Palmeri, Matteo; Simoncini, Tommaso; Cela, Vito; Perutelli, Alessandra; Selli, Cesare; Buccianti, Piero; Francesca, Francesco; Cecchi, Massimo; Zirafa, Cristina; Bastiani, Luca; Cuschieri, Alfred; Melfi, Franca

    2018-03-30

    The da Vinci® Table Motion (dVTM) comprises a combination of a unique operating table (Trumpf Medical™ TruSystem® 7000dV) capable of isocenter motion connected wirelessly with the da Vinci Xi® robotic platform, thereby enabling patients to be repositioned without removal of instruments and or undocking the robot. Between May 2015 to October 2015, the first human use of dVTM was carried out in this prospective, single-arm, post-market study in the EU, for which 40 patients from general surgery (GS), urology (U), or gynecology (G) were enrolled prospectively. Primary endpoints of the study were dVTM feasibility, efficacy, and safety. Surgeons from the three specialties obtained targeting success and the required table positioning in all cases. Table movement/repositioning was necessary to gain exposure of the operating field in 106/116 table moves (91.3%), change target in 2/116 table moves (1.7%), achieve hemodynamic relief in 4/116 table moves (3.5%), and improve external access for tumor removal in 4/116 table moves (3.5%). There was a significantly higher use of tilt and tilt plus Trendelenburg in GS group (GS vs. U p = 0.055 and GS vs. G p = 0.054). There were no dVTM safety-related or adverse events. The dVTM with TruSystem 7000dV operating table in wireless communication with the da Vinci Xi is a perfectly safe and effective synergistic combination, which allows repositioning of the patient whenever needed without imposing any delay in the execution of the operation. Moreover, it is helpful in avoiding extreme positions and enables the anesthesiologist to provide immediate and effective hemodynamic relief to the patient when needed.

  4. Successful treatment of esophageal metastasis from hepatocellular carcinoma using the da Vinci robotic surgical system

    PubMed Central

    Boonnuch, Wiroon; Akaraviputh, Thawatchai; Nino, Carnivale; Yiengpruksawan, Anusak; Christiano, Arthur Andrew

    2011-01-01

    A 59-year-old man with metastatic an esophageal tumor from hepatocellular carcinoma (HCC) presented with progressive dysphagia. He had undergone liver transplantation for HCC three and a half years prevously. At presentation, his radiological and endoscopic examinations suggested a submucosal tumor in the lower esophagus, causing a luminal stricture. We performed complete resection of the esophageal metastases and esophagogastrostomy reconstruction using the da Vinci robotic system. Recovery was uneventful and he was been doing well 2 mo after surgery. α-fetoprotein level decreased from 510 ng/mL to 30 ng/mL postoperatively. During the follow-up period, he developed a recurrent esophageal stricture at the anastomosis site and this was successfully treated by endoscopic esophageal dilatation. PMID:21765971

  5. Understanding the adoption dynamics of medical innovations: affordances of the da Vinci robot in the Netherlands.

    PubMed

    Abrishami, Payam; Boer, Albert; Horstman, Klasien

    2014-09-01

    This study explored the rather rapid adoption of a new surgical device - the da Vinci robot - in the Netherlands despite the high costs and its controversial clinical benefits. We used the concept 'affordances' as a conceptual-analytic tool to refer to the perceived promises, symbolic meanings, and utility values of an innovation constructed in the wider social context of use. This concept helps us empirically understand robot adoption. Data from 28 in-depth interviews with diverse purposively-sampled stakeholders, and from medical literature, policy documents, Health Technology Assessment reports, congress websites and patients' weblogs/forums between April 2009 and February 2014 were systematically analysed from the perspective of affordances. We distinguished five interrelated affordances of the robot that accounted for shaping and fulfilling its rapid adoption: 'characteristics-related' affordances such as smart nomenclature and novelty, symbolising high-tech clinical excellence; 'research-related' affordances offering medical-technical scientific excellence; 'entrepreneurship-related' affordances for performing better-than-the-competition; 'policy-related' affordances indicating the robot's liberalised provision and its reduced financial risks; and 'communication-related' affordances of the robot in shaping patients' choices and the public's expectations by resonating promising discourses while pushing uncertainties into the background. These affordances make the take-up and use of the da Vinci robot sound perfectly rational and inevitable. This Dutch case study demonstrates the fruitfulness of the affordances approach to empirically capturing the contextual dynamics of technology adoption in health care: exploring in-depth actors' interaction with the technology while considering the interpretative spaces created in situations of use. This approach can best elicit real-life value of innovations, values as defined through the eyes of (potential) users

  6. [Leonardo da Vinci the first human body imaging specialist. A brief communication on the thorax oseum images].

    PubMed

    Cicero, Raúl; Criales, José Luis; Cardoso, Manuel

    2009-01-01

    The impressive development of computed tomography (CT) techniques such as the three dimensional helical CT produces a spatial image of the thoracic skull. At the beginning of the 16th century Leonardo da Vinci drew with great precision the thorax oseum. These drawings show an outstanding similarity with the images obtained by three dimensional helical CT. The cumbersome task of the Renaissance genius is a prime example of the careful study of human anatomy. Modern imaging techniques require perfect anatomic knowledge of the human body in order to generate exact interpretations of images. Leonardo's example is alive for anybody devoted to modern imaging studies.

  7. Leonardo da Vinci: engineer, bioengineer, anatomist, and artist.

    PubMed

    West, John B

    2017-03-01

    Leonardo da Vinci (1452-1519) enjoys a reputation as one of the most talented people of all time in the history of science and the arts. However, little attention has been given to his contributions to physiology. One of his main interests was engineering, and he was fascinated by structural problems and the flow patterns of liquids. He also produced a large number of ingenious designs for warfare and a variety of highly original flying machines. But of particular interest to us are his contributions to bioengineering and how he used his knowledge of basic physical principles to throw light on physiological function. For example, he produced new insights into the mechanics of breathing including the action of the ribs and diaphragm. He was the first person to understand the different roles of the internal and external intercostal muscles. He had novel ideas about the airways including the mode of airflow in them. He also worked on the cardiovascular system and had a special interest in the pulmonary circulation. But, interestingly, he was not able to completely divorce his views from those of Galen, in that although he could not see pores in the interventricular septum of the heart, one of his drawings included them. Leonardo was a talented anatomist who made many striking drawings of the human body. Finally, his reputation for many people is based on his paintings including the Mona Lisa that apparently attracts more viewers than any other painting in the world. Copyright © 2017 the American Physiological Society.

  8. First series of total robotic hysterectomy (TRH) using new integrated table motion for the da Vinci Xi: feasibility, safety and efficacy.

    PubMed

    Giannini, Andrea; Russo, Eleonora; Mannella, Paolo; Palla, Giulia; Pisaneschi, Silvia; Cecchi, Elena; Maremmani, Michele; Morelli, Luca; Perutelli, Alessandra; Cela, Vito; Melfi, Franca; Simoncini, Tommaso

    2017-08-01

    To present the first case series of total robotic hysterectomy (TRH), using integrated table motion (ITM), which is a new feature comprising a unique operating table by Trumpf Medical that communicates wirelessly with the da Vinci Xi surgical system. ITM has been specifically developed to improve multiquadrant robotic surgery such as that conducted in colorectal surgery. Between May and October 2015, a prospective post-market study was conducted on ITM in the EU in 40 cases from different specialties. The gynecological study group comprised 12 patients. Primary endpoints were ITM feasibility, safety and efficacy. Ten patients underwent TRH. Mean number of ITM moves was three during TRH; there were 31 instances of table moves in the ten procedures. Twenty-eight of 31 ITM moves were made to gain internal exposure. The endoscope remained inserted during 29 of the 31 table movements (94%), while the instruments remained inserted during 27 of the 31 moves (87%). No external instrument collisions or other problems related to the operating table were noted. There were no ITM safety-related observations and no adverse events. This preliminary study demonstrated the feasibility, safety and efficacy of ITM for the da Vinci Xi surgical system in TRH. ITM was safe, with no adverse events related to its use. Further studies will be useful to define the real role and potential benefit of ITM in gynecological surgery.

  9. Application of da Vinci(®) Robot in simple or radical hysterectomy: Tips and tricks.

    PubMed

    Iavazzo, Christos; Gkegkes, Ioannis D

    2016-01-01

    The first robotic simple hysterectomy was performed more than 10 years ago. These days, robotic-assisted hysterectomy is accepted as an alternative surgical approach and is applied both in benign and malignant surgical entities. The two important points that should be taken into account to optimize postoperative outcomes in the early period of a surgeon's training are how to achieve optimal oncological and functional results. Overcoming any technical challenge, as with any innovative surgical method, leads to an improved surgical operation timewise as well as for patients' safety. The standardization of the technique and recognition of critical anatomical landmarks are essential for optimal oncological and clinical outcomes on both simple and radical robotic-assisted hysterectomy. Based on our experience, our intention is to present user-friendly tips and tricks to optimize the application of a da Vinci® robot in simple or radical hysterectomies.

  10. Leonardo da Vinci and the first hemodynamic observations.

    PubMed

    Martins e Silva, J

    2008-02-01

    Leonardo da Vinci was a genius whose accomplishments and ideas come down to us today, five centuries later, with the freshness of innovation and the fascination of discovery. This brief review begins with a summary of Leonardo's life and a description of the most important works of art that he bequeathed us, and then concentrates on his last great challenge. There was a point at which Leonardo's passion for art gave way to the study of human anatomy, not only to improve his drawing but to go beyond what had been simply a representation of form to understand the underlying functioning. Among his many interests, we focus on his study of the heart and blood vessels, which he observed carefully in animals and human autopsies, and reproduced in drawings of great quality with annotations of astonishing acuteness. The experience that he had acquired from observing the flow of water in currents and around obstacles, and the conclusions that he drew concerning hydrodynamics, were central to his interpretation of the mechanisms of the heart and of blood flow, to which he devoted much of his time between 1508 and 1513. From these studies, immortalized in drawings of great clarity, come what are acknowledged to be the first hemodynamic records, in which Leonardo demonstrates the characteristics of blood flow in the aorta and great vessels and the importance of blood reflux and the formation of eddies in the sinus in aortic valve his assiduous and careful observations, and his subsequent deductions, Leonardo put forward detailed findings on hemodynamic questions that advanced technology has only recently enabled us to confirm.

  11. [The history of prostate cancer from the beginning to DaVinci].

    PubMed

    Hatzinger, M; Hubmann, R; Moll, F; Sohn, M

    2012-07-01

    For hardly any other organ can the development of medicine and technical advances in the last 150 years be so clearly illustrated as for the prostate. The history of radical prostatectomy was initially characterised by the problems in approaching this relatively difficulty accessible organ. In 1867, Theodor Billroth in Vienna performed the first partial prostatectomy via a perineal access. In 1904, Hugh Hampton Young and William Stewart Halsted at the Johns Hopkins Hospital in Baltimore / USA carried out the first successful extracapsular perineal prostatectomy and opened up a new era. In Germany, Prof. Friedrich Voelcker in Halle in 1924 developed the so-called ischiorectal prostatectomy. But it was left to Terence Millin to publish in 1945 the first series of retropubic prostatectomies. In 1952, the sacroperineal approach according to Thiermann and the sacral prostatectomy according to were introduced. Finally, in 1991 another new era in prostate surgery started with the first laparoscopic prostatectomy. This development peaked in 2011 with the presentation of the laparoscopic DaVinci prostatectomy by Binder. Originally a stepchild of urological surgery that was to be avoided whenever possible due to the fear of serious complications, the prostate has progressed in the course of time to an obscure object of lust. The stepchild has become the favorite child.

  12. [Mechatronic in functional endoscopic sinus surgery. First experiences with the daVinci Telemanipulatory System].

    PubMed

    Strauss, G; Winkler, D; Jacobs, S; Trantakis, C; Dietz, A; Bootz, F; Meixensberger, J; Falk, V

    2005-07-01

    This study examines the advantages and disadvantages of a commercial telemanipulator system (daVinci, Intuitive Surgical, USA) with computer-guided instruments in functional endoscopic sinus surgery (FESS). We performed five different surgical FESS steps on 14 anatomical preparation and compared them with conventional FESS. A total of 140 procedures were examined taking into account the following parameters: degrees of freedom (DOF), duration , learning curve, force feedback, human-machine-interface. Telemanipulatory instruments have more DOF available then conventional instrumentation in FESS. The average time consumed by configuration of the telemanipulator is around 9+/-2 min. Missing force feedback is evaluated mainly as a disadvantage of the telemanipulator. Scaling was evaluated as helpful. The ergonomic concept seems to be better than the conventional solution. Computer guided instruments showed better results for the available DOF of the instruments. The human-machine-interface is more adaptable and variable then in conventional instrumentation. Motion scaling and indexing are characteristics of the telemanipulator concept which are helpful for FESS in our study.

  13. Stray electrical currents in laparoscopic instruments used in da Vinci® robot-assisted surgery: an in vitro study.

    PubMed

    Mendez-Probst, Carlos E; Vilos, George; Fuller, Andrew; Fernandez, Alfonso; Borg, Paul; Galloway, David; Pautler, Stephen E

    2011-09-01

    The da Vinci(®) surgical system requires the use of electrosurgical instruments. The re-use of such instruments creates the potential for stray electrical currents from capacitive coupling and/or insulation failure. We used objective measures to report the prevalence and magnitude of such stray currents. Thirty-seven robotic instruments were tested using an electrosurgical unit (ESU) at pure coagulation and cut waveforms at four different settings. Conductive gel-coated instruments were tested at 40W, 80W, and maximum ESU output (coagulation 120W, cut 300W). The magnitude of stray currents was measured by an electrosurgical analyzer. At coagulation waveform in open air, 86% of instruments leaked a mean of 0.4W. In the presence of gel-coated instruments, stray currents were detected in all instruments with means (and standard deviation) of 3.4W (± 2), 4.1W (± 2.3), and 4.1W (± 2.3) at 40W, 80W, and 120W, respectively. At cut waveform in open air, none of the instruments leaked current, while gel-coated instruments leaked a mean of 2.2W (± 1.3), 2.2W (± 1.9) and 3.2W (± 1.9) at 40W, 80W, and 300W, respectively. All tested instruments in our study demonstrated energy leakage. Stray currents were higher during coagulation (high voltage) waveforms, and the magnitude was not always proportionate to the ESU settings. Stray currents have the potential to cause electrical burns. We support the programmed end of life of da Vinci instruments on the basis of safety. Consideration should be given to alternate energy sources or the adoption of active electrode monitoring technology to all monopolar instruments.

  14. Single-Port Surgery: Laboratory Experience with the daVinci Single-Site Platform

    PubMed Central

    Haber, Georges-Pascal; Kaouk, Jihad; Kroh, Matthew; Chalikonda, Sricharan; Falcone, Tommaso

    2011-01-01

    Background and Objectives: The purpose of this study was to evaluate the feasibility and validity of a dedicated da Vinci single-port platform in the porcine model in the performance of gynecologic surgery. Methods: This pilot study was conducted in 4 female pigs. All pigs had a general anesthetic and were placed in the supine and flank position. A 2-cm umbilical incision was made, through which a robotic single-port device was placed and pneumoperitoneum obtained. A data set was collected for each procedure and included port placement time, docking time, operative time, blood loss, and complications. Operative times were compared between cases and procedures by use of the Student t test. Results: A total of 28 surgical procedures (8 oophorectomies, 4 hysterectomies, 8 pelvic lymph node dissections, 4 aorto-caval nodal dissections, 2 bladder repairs, 1 uterine horn anastomosis, and 1 radical cystectomy) were performed. There was no statistically significant difference in operating times for symmetrical procedures among animals (P=0.3215). Conclusions: This animal study demonstrates that single-port robotic surgery using a dedicated single-site platform allows performing technically challenging procedures within acceptable operative times and without complications or insertion of additional trocars. PMID:21902962

  15. Da Vinci Robotic Surgery in a Pediatric Hospital.

    PubMed

    Mattioli, Girolamo; Pini Prato, Alessio; Razore, Barbara; Leonelli, Lorenzo; Pio, Luca; Avanzini, Stefano; Boscarelli, Alessandro; Barabino, Paola; Disma, Nicola Massimo; Zanaboni, Clelia; Garzi, Alfredo; Martigli, Sofia Paola; Buffi, Nicolò Maria; Rosati, Ubaldo; Petralia, Paolo

    2017-05-01

    Since the use of robotic surgery (RS) revolutionized some adult surgery procedures such as radical prostatectomy, it has been progressively and increasingly introduced in pediatric surgery. The aim of this study is to evaluate how the Da Vinci ® Si HD technology impacts a pediatric public hospital and to define the use of a robotic system in pediatric surgery. We prospectively included patients older than 6 months of age undergoing RS or conventional minimal access surgery (MAS): Study period ranges between February 2015 and April 2016. Surgical indications were defined after a detailed disease-specific diagnostic work-up. We analyzed surgical outcomes and the most relevant economic aspects. The 30-day postoperative complications were evaluated and retrospectively collected in an electronic database. From February 2015 to April 2016, we performed 77 procedures with RS and 84 with conventional MAS in patients with a median age of 77 and 98 months at surgery and a median weight of 20 and 23 kg, respectively. Median operative times were 130 and 109 minutes, respectively. We observed 9.1% of complications in the RS group and 6% in the MAS group and the difference was not statistically significant. Of note, 8 out of 77 RS procedures would have been performed with open classic surgery in case of conversion or failure of RS. This initial experience confirms that RS is as safe and effective as conventional MAS. A number of selected procedures performed with RS would only benefit from this approach, as it is not suitable for conventional MAS. Although economically demanding, in particular for a pediatric hospital, we firmly believe that centralization of care would allow pediatric surgeons adopting RS to perform complex reconstructive surgical procedures with great advantages for the patients and a minimal increase in overall costs for the health system.

  16. Surgical outcomes of robot-assisted rectal cancer surgery using the da Vinci Surgical System: a multi-center pilot Phase II study.

    PubMed

    Tsukamoto, Shunsuke; Nishizawa, Yuji; Ochiai, Hiroki; Tsukada, Yuichiro; Sasaki, Takeshi; Shida, Dai; Ito, Masaaki; Kanemitsu, Yukihide

    2017-12-01

    We conducted a multi-center pilot Phase II study to examine the safety of robotic rectal cancer surgery performed using the da Vinci Surgical System during the introduction period of robotic rectal surgery at two institutes based on surgical outcomes. This study was conducted with a prospective, multi-center, single-arm, open-label design to assess the safety and feasibility of robotic surgery for rectal cancer (da Vinci Surgical System). The primary endpoint was the rate of adverse events during and after robotic surgery. The secondary endpoint was the completion rate of robotic surgery. Between April 2014 and July 2016, 50 patients were enrolled in this study. Of these, 10 (20%) had rectosigmoid cancer, 17 (34%) had upper rectal cancer, and 23 (46%) had lower rectal cancer; six underwent high anterior resection, 32 underwent low anterior resection, 11 underwent intersphincteric resection, and one underwent abdominoperineal resection. Pathological stages were Stage 0 in 1 patient, Stage I in 28 patients, Stage II in 7 patients and Stage III in 14 patients. Pathologically complete resection was achieved in all patients. There was no intraoperative organ damage or postoperative mortality. Eight (16%) patients developed complications of all grades, of which 2 (4%) were Grade 3 or higher, including anastomotic leakage (2%) and conversion to open surgery (2%). The present study demonstrates the feasibility and safety of robotic rectal cancer surgery, as reflected by low morbidity and low conversion rates, during the introduction period. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. Elastography Using Multi-Stream GPU: An Application to Online Tracked Ultrasound Elastography, In-Vivo and the da Vinci Surgical System

    PubMed Central

    Deshmukh, Nishikant P.; Kang, Hyun Jae; Billings, Seth D.; Taylor, Russell H.; Hager, Gregory D.; Boctor, Emad M.

    2014-01-01

    A system for real-time ultrasound (US) elastography will advance interventions for the diagnosis and treatment of cancer by advancing methods such as thermal monitoring of tissue ablation. A multi-stream graphics processing unit (GPU) based accelerated normalized cross-correlation (NCC) elastography, with a maximum frame rate of 78 frames per second, is presented in this paper. A study of NCC window size is undertaken to determine the effect on frame rate and the quality of output elastography images. This paper also presents a novel system for Online Tracked Ultrasound Elastography (O-TRuE), which extends prior work on an offline method. By tracking the US probe with an electromagnetic (EM) tracker, the system selects in-plane radio frequency (RF) data frames for generating high quality elastograms. A novel method for evaluating the quality of an elastography output stream is presented, suggesting that O-TRuE generates more stable elastograms than generated by untracked, free-hand palpation. Since EM tracking cannot be used in all systems, an integration of real-time elastography and the da Vinci Surgical System is presented and evaluated for elastography stream quality based on our metric. The da Vinci surgical robot is outfitted with a laparoscopic US probe, and palpation motions are autonomously generated by customized software. It is found that a stable output stream can be achieved, which is affected by both the frequency and amplitude of palpation. The GPU framework is validated using data from in-vivo pig liver ablation; the generated elastography images identify the ablated region, outlined more clearly than in the corresponding B-mode US images. PMID:25541954

  18. Elastography using multi-stream GPU: an application to online tracked ultrasound elastography, in-vivo and the da Vinci Surgical System.

    PubMed

    Deshmukh, Nishikant P; Kang, Hyun Jae; Billings, Seth D; Taylor, Russell H; Hager, Gregory D; Boctor, Emad M

    2014-01-01

    A system for real-time ultrasound (US) elastography will advance interventions for the diagnosis and treatment of cancer by advancing methods such as thermal monitoring of tissue ablation. A multi-stream graphics processing unit (GPU) based accelerated normalized cross-correlation (NCC) elastography, with a maximum frame rate of 78 frames per second, is presented in this paper. A study of NCC window size is undertaken to determine the effect on frame rate and the quality of output elastography images. This paper also presents a novel system for Online Tracked Ultrasound Elastography (O-TRuE), which extends prior work on an offline method. By tracking the US probe with an electromagnetic (EM) tracker, the system selects in-plane radio frequency (RF) data frames for generating high quality elastograms. A novel method for evaluating the quality of an elastography output stream is presented, suggesting that O-TRuE generates more stable elastograms than generated by untracked, free-hand palpation. Since EM tracking cannot be used in all systems, an integration of real-time elastography and the da Vinci Surgical System is presented and evaluated for elastography stream quality based on our metric. The da Vinci surgical robot is outfitted with a laparoscopic US probe, and palpation motions are autonomously generated by customized software. It is found that a stable output stream can be achieved, which is affected by both the frequency and amplitude of palpation. The GPU framework is validated using data from in-vivo pig liver ablation; the generated elastography images identify the ablated region, outlined more clearly than in the corresponding B-mode US images.

  19. Effect of training frequency on the learning curve on the da Vinci Skills Simulator.

    PubMed

    Walliczek, Ute; Förtsch, Arne; Dworschak, Philipp; Teymoortash, Afshin; Mandapathil, Magis; Werner, Jochen; Güldner, Christian

    2016-04-01

    The purpose of this study was to evaluate the effect of training on the performance outcome with the da Vinci Skills Simulator. Forty novices were enrolled in a prospective training curriculum. Participants were separated into 2 groups. Group 1 performed 4 training sessions and group 2 had 2 training sessions over a 4-week period. Five exercises were performed 3 times consecutively. On the last training day, a new exercise was added. A significant skills gain from the first to the final practice day in overall performance, time to complete, and economy of motion was seen for both groups. Group 1 had a significantly better outcome in overall performance, time to complete, and economy of motion in all exercises. There was no significant difference found regarding the new exercise in group 1 versus group 2 in nearly all parameters. Longer time distances between training sessions are assumed to play a secondary role, whereas total repetition frequency is crucial for improvement of technical performance. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1762-E1769, 2016. © 2015 Wiley Periodicals, Inc.

  20. [Leonardo da Vinci and his studies on the human fetus and the placenta].

    PubMed

    Cataldi, L; Fanos, V

    2000-01-01

    To review the accuracy of Leonardo's anatomical studies of the female external genitalia and the foetus, particularly those concerning the umbilical cord with its blood vessels. The anatomical drawings of Leonardo da Vinci which are now stored in the Windors Castle near London were reviewed and the accuracy of the details of the genital apparatus and foetus was evaluated. A written comment characterizes many of his drawings. He described accurately the position of the uterine blood vessels and the relationship between the pelvic organs. However his drawing and description of the female external genitalia and human placenta was incorrect because his understanding of it was inadequate. He believed that the human placenta had cotyledons like that of the ungulate uterus (drown side A of sheet 19). At the top of that sheet some Leonardo's details of the anatomic relationship are shown. In our opinion, Leonardo's misunderstanding is probably because he was only able to perform one anatomical dissection of a pregnant women and foetus and therefore his knowledge was limited. The resulting documentation of the pregnant women and foetus was therefore heavily supplemented with his enormous experience in animal anatomy.

  1. Leonardo da Vinci's drapery studies: characterization of lead white pigments by µ-XRD and 2D scanning XRF

    NASA Astrophysics Data System (ADS)

    Gonzalez, Victor; Calligaro, Thomas; Pichon, Laurent; Wallez, Gilles; Mottin, Bruno

    2015-11-01

    This work focuses on the composition and microstructure of the lead white pigment employed in a set of paintworks, using a combination of µ-XRD and 2D scanning XRF, directly applied on five drapery studies attributed to Leonardo da Vinci (1452-1519) and conserved in the Département des Arts Graphiques, Musée du Louvre and in the Musée des Beaux- Arts de Rennes. Trace elements present in the composition as well as in the lead white highlights were imaged by 2D scanning XRF. Mineral phases were determined in a fully noninvasive way using a special µ-XRD diffractometer. Phase proportions were estimated by Rietveld refinement. The analytical results obtained will contribute to differentiate lead white qualities and to highlight the artist's technique.

  2. Leonardo da Vinci's "A skull sectioned": skull and dental formula revisited.

    PubMed

    Gerrits, Peter O; Veening, Jan G

    2013-05-01

    What can be learned from historical anatomical drawings and how to incorporate these drawings into anatomical teaching? The drawing "A skull sectioned" (RL 19058v) by Leonardo da Vinci (1452-1519), hides more detailed information than reported earlier. A well-chosen section cut explores sectioned paranasal sinuses and ductus nasolacrimalis. A dissected lateral wall of the maxilla is also present. Furthermore, at the level of the foramen mentale, the drawing displays compact and spongious bony components, together with a cross-section through the foramen mentale and its connection with the canalis mandibulae. Leonardo was the first to describe a correct dental formula (6424) and made efforts to place this formula above the related dental elements. However, taking into account, the morphological features of the individual elements of the maxilla, it can be suggested that Leonardo sketched a "peculiar dental element" on the position of the right maxillary premolar in the dental sketch. The fact that the author did not make any comment on that special element is remarkable. Leonardo could have had sufficient knowledge of the precise morphology of maxillary and mandibular premolars, since the author depicted these elements in the dissected skull. The fact that the author also had access to premolars in situ corroborates our suggestion that "something went wrong" in this part of the drawing. The present study shows that historical anatomical drawings are very useful for interactive learning of detailed anatomy for students in medicine and dentistry. Copyright © 2012 Wiley Periodicals, Inc.

  3. Realization and optimization of AES algorithm on the TMS320DM6446 based on DaVinci technology

    NASA Astrophysics Data System (ADS)

    Jia, Wen-bin; Xiao, Fu-hai

    2013-03-01

    The application of AES algorithm in the digital cinema system avoids video data to be illegal theft or malicious tampering, and solves its security problems. At the same time, in order to meet the requirements of the real-time, scene and transparent encryption of high-speed data streams of audio and video in the information security field, through the in-depth analysis of AES algorithm principle, based on the hardware platform of TMS320DM6446, with the software framework structure of DaVinci, this paper proposes the specific realization methods of AES algorithm in digital video system and its optimization solutions. The test results show digital movies encrypted by AES128 can not play normally, which ensures the security of digital movies. Through the comparison of the performance of AES128 algorithm before optimization and after, the correctness and validity of improved algorithm is verified.

  4. The handedness of Leonardo da Vinci: a tale of the complexities of lateralisation.

    PubMed

    McManus, I C; Drury, Helena

    2004-07-01

    The handedness of Leonardo da Vinci is controversial. Although there is little doubt that many of his well-attributed drawings were drawn with the left hand, the hatch marks of the shading going downwards from left to right, it is not clear that he was a natural left-hander, there being some suggestion that he may have become left-handed as the result of an injury to his right hand in early adulthood. Leonardo's lateralisation may be illuminated by an obscure passage in his notebooks in which he describes crouching down to look into a dark cave, putting his left hand on his knee, and shading his eyes with his right hand. We carried out a questionnaire survey, using 33 written and photographic items, to find whether this behaviour was typical of right handers or left handers. In fact the 'Leonardo task' showed almost no direct association with handedness, meaning that it contributes little to the immediate problem of elucidating Leonardo's handedness. However, the lateralisation of the task did relate to other aspects of behavioural laterality in surprisingly complex ways. This suggests that individual differences in handedness, and behavioural laterality in general, have a structural complexity which is not fully encompassed by simple measures of direction or degree of handedness.

  5. Sentinel Node Mapping Using Indocyanine Green and Near-infrared Fluorescence Imaging Technology for Uterine Malignancies: Preliminary Experience With the Da Vinci Xi System.

    PubMed

    Siesto, Gabriele; Romano, Fabrizio; Fiamengo, Barbara; Vitobello, Domenico

    2016-01-01

    Sentinel lymph node (SLN) mapping has emerged as the new frontier for the surgical staging of apparently early-stage cervical and endometrial cancer. Different colorimetric and radioactive tracers, alone and in combination, have been proposed with encouraging results. Fluorometric mapping using indocyanine green (ICG) appears to be a suitable and attractive alternative to provide reliable staging [1-4]. In this video, we present the technique of SLN mapping in 2 cases (1 endometrial and 1 cervical cancer, respectively) using ICG and the near-infrared technology provided by the newest Da Vinci Xi robotic system (Intuitive Surgical Inc., Sunnyvale, CA). Together we report the results of our preliminary experience on the first 20 cases performed. The new robotic Da Vinci Xi system was available at our institution since May 2015. Upon institutional review board/ethical committee approval, all consecutive patients with early-stage endometrial and cervical cancer who were judged suitable for robotic surgery have been enrolled for SLN mapping with ICG. We adopted the Memorial Sloan Kettering Cancer Center SLN algorithm; the tracer was delivered into the cervix in all cases. Four milliliters (1.25 mg/mL) of ICG was injected divided into the 3- and 9-o'clock positions of the cervix alone, with 1 mL deep into the stroma and 1 mL submucosally at the skin incision. Sentinel lymph nodes were examined with a protocol including both ultrastaging with immunohistochemistry [3] and 1-step nucleic acid amplification assay [5,6] under a parallel protocol of study. During the study period, 20 cases were managed; 14 and 6 patients had endometrial and cervical cancer, respectively. SLN was detected in all cases (20/20, 100%). Bilateral SLNs were detected in 17 of 20 (85.0%) cases. Based on preoperative and intraoperative findings, 13 (65.0%) patients received systematic pelvic lymphadenectomy after SLN mapping. Three (15.0%) patients had microscopic nodal metastases on SLN. No

  6. Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system.

    PubMed

    Blavier, A; Gaudissart, Q; Cadière, G B; Nyssen, A S

    2006-01-01

    The aim of this study was to evaluate the impact of 3D and 2D vision on performance of novice subjects using da Vinci robotic system. 224 nurses without any surgical experience were divided into two groups and executed a motor task with the robotic system in 2D for one group and with the robotic system in 3D for the other group. Time to perform the task was recorded. Our data showed significant better time performance in 3D view (24.67 +/- 11.2) than in 2D view (40.26 +/- 17.49, P < 0.001). Our findings emphasized the advantage of 3D vision over 2D view in performing surgical task, encouraging the development of efficient and less expensive 3D systems in order to improve the accuracy of surgical gesture, the resident training and the operating time.

  7. Using Optical Coherence Tomography to Reveal the Hidden History of The Landsdowne Virgin of the Yarnwinder by Leonardo da Vinci and Studio.

    PubMed

    Targowski, Piotr; Iwanicka, Magdalena; Sylwestrzak, Marcin; Frosinini, Cecilia; Striova, Jana; Fontana, Raffaella

    2018-06-18

    Optical coherence tomography (OCT) was used for non-invasive examination of a well-known, yet complex, painting from the studio of Leonardo da Vinci in combination with routine imaging in various bands of electromagnetic radiation. In contrast with these techniques, OCT provides depth-resolved information. Three post-processing modalities were explored: cross-sectional views, maps of scattering from given depths, and their 3D models. Some hidden alterations of the painting owing to past restorations were traced: retouching and overpainting with their positioning within varnish layers as well as indications of a former transfer to canvas. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Universal suprapubic approach for complete mesocolic excision and central vascular ligation using the da Vinci Xi® system: from cadaveric models to clinical cases.

    PubMed

    Yeo, Shen Ann; Noh, Gyoung Tae; Han, Jeong Hee; Cheong, Chinock; Stein, Hubert; Kerdok, Amy; Min, Byung Soh

    2017-12-01

    There has been little enthusiasm for performing robotic colectomy for colon cancer in recent years due to multiple factors, one being that the previous robotic systems such as the da Vinci Si ® (dVSi) were poorly designed for multi-quadrant surgery. The new da Vinci Xi ® (dVXi) system enables colectomy with central mesocolic excision to be performed easily in a single docking procedure. We developed a universal port placement strategy to allow right and left hemicolectomies to be performed via a suprapubic approach and a Pfannensteil extraction site. This proof of concept paper describes the development and subsequent clinical application of this setup. After extensive training on the dVXi system concepts in collaboration with clinical development engineers, we developed a port placement strategy which was tested and adapted after performing experimental surgery in three cadaveric models. Subsequently our port placement was used for two clinical cases of suprapubic right and left hemicolectomy. With some modifications of port placements after the initial cadaveric colectomies, we have developed a potentially universal suprapubic port placement strategy for robotic colectomy with complete mesocolic excision and central vascular ligation using the dVXi robotic system. This port placement strategy was applied successfully in our first two clinical cases. Based on our cadaveric laboratory as well as our initial clinical application, the suprapubic port placement strategy for the dVXi system with its improved features over the dVSi can feasibly perform right and left hemicolectomy with complete mesocolic excision and central vascular ligation. Further studies will be required to establish efficacy as well as safety profile of these procedures.

  9. Sponsoring surgeons; an investigation on the influence of the da Vinci robot.

    PubMed

    Criss, Cory N; Gadepalli, Samir K

    2017-08-26

    The integrity of the medical literature about robotic surgery remains unclear despite wide-spread adoption. We sought to determine if payment from Intuitive Surgical Incorporated (ISI) affected quality of the research produced by surgeons. Publicly available financial data from the CMS website regarding the top-20 earners from ISI for 2015 was gathered. Studies conducted by these surgeons were identified using PubMed. Inclusion criteria consisted of publications about the da Vinci ® robot on patient outcomes. The primary outcome of our study was if the study conclusion was positive/equivocal/negative towards the robot. Secondary outcomes included authorship, sponsorship, study controls, and disclosure. The top earners received $3,296,844 in 2015, with a median of $141,959. Sub-specialties included general surgery (55%), colorectal (20%), thoracic (15%), and obstetrics/gynecology (10%). Of the 37 studies, there was 1 RCT, with observational studies comprising the rest. The majority of the studies (n = 16, 43%) had no control population, with 11 (30%) comparing to same institution/surgeon, Though ISI sponsored only 6 (16%) studies, all with positive conclusions, 27 (73%) studies had positive conclusions for robot use, 9 (24%) equivocal, and only 1 (3%) negative. Overall, 13 earners had lead authorship and 11 senior. This initial pilot study highlights a potential bias as current literature published by benefactors demonstrates low quality and highly positive conclusions towards approval of the robot. This substantiates the need for a large, systematic review of the potential influence of sponsoring surgeons on medical literature. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. The mother relationship and artistic inhibition in the lives of Leonardo da Vinci and Erik H. Erikson.

    PubMed

    Capps, Donald

    2008-12-01

    In four earlier articles, I focused on the theme of the relationship of melancholia and the mother, and suggested that the melancholic self may experience humor (Capps, 2007a), play (Capps, 2007b), dreams (Capps, 2008a), and art (Capps, 2008b) as restorative resources. I argued that Erik H. Erikson found these resources to be valuable remedies for his own melancholic condition, which had its origins in the fact that he was illegitimate and was raised solely by his mother until he was three years old, when she remarried. In this article, I focus on two themes in Freud's Leonardo da Vinci and a memory of his childhood (1964): Leonardo's relationship with his mother in early childhood and his inhibitions as an artist. I relate these two themes to Erikson's own early childhood and his failure to achieve his goal as an aspiring artist in his early twenties. The article concludes with a discussion of Erikson's frustrated aspirations to become an artist and his emphasis, in his psychoanalytic work, on children's play.

  11. The proportion of the face in younger adults using the thumb rule of Leonardo da Vinci.

    PubMed

    Oguz, O

    1996-01-01

    The present study was conducted to examine whether the thumb rule of Leonardo da Vinci could be an objective method in the determination of the natural and artistic proportions of human face. In this study, a sample of 400 subjects (200 male and 200 female, 22-25 years old) was used. Measurements were made of the length of thumb, the length of ear, the approximate distances between the hair line and the glabella or eyebrows, between the glabella or eyebrows and the tip of the nose and the distance between the nose and the chin, and the distance between the ear and the lateral aspect of the eye. The results obtained in the males and females showed significant (p < 0.01) correlations between the length of thumb and the proportions of the face examined in the study. Additionally, the height of the face was found to be almost three times the length of the thumb. However, the measurements obtained from female subjects were on average smaller than those taken from males. The results obtained in this experiment could be of value in understanding of the evaluation of the face for the people working in plastic surgery or art.

  12. Robotic-Assisted Sleeve Lobectomy Using the Four-Arm Technique in the DaVinci Si® and Xi® Systems.

    PubMed

    Egberts, Jan-Hendrik; Möller, Thorben; Becker, Thomas

    2018-06-16

    Sleeve lobectomy (SL) makes it possible to resect centrally located lung carcinoma oncological correct while protecting healthy lung tissue. However, this procedure is often limited with conventional video-assisted thoracoscopic surgery, due to the limited mobility of the rigid and long instruments and the limited visualization. Therefore, these interventions are often still performed in the open conventional technique with the well-known disadvantages. Particularly in the reconstruction of the respiratory tract, precise sewing must be performed in a small space to avoid stenosis of the different diameter of the lumina. Robotic surgery offers several advantages through an enlarged three-dimensional view and flexibility of the robotic instruments, which are particularly evident when sewing. So far, there are only a few reports of robotic SL. Here, we describe our experience of performing robotic SL with four arms on both, the currently available DaVinci Xi ® and Si ® systems. Georg Thieme Verlag KG Stuttgart · New York.

  13. VINCI: the VLT Interferometer commissioning instrument

    NASA Astrophysics Data System (ADS)

    Kervella, Pierre; Coudé du Foresto, Vincent; Glindemann, Andreas; Hofmann, Reiner

    2000-07-01

    The Very Large Telescope Interferometer (VLTI) is a complex system, made of a large number of separated elements. To prepare an early successful operation, it will require a period of extensive testing and verification to ensure that the many devices involved work properly together, and can produce meaningful data. This paper describes the concept chosen for the VLTI commissioning instrument, LEONARDO da VINCI, and details its functionalities. It is a fiber based two-way beam combiner, associated with an artificial star and an alignment verification unit. The technical commissioning of the VLTI is foreseen as a stepwise process: fringes will first be obtained with the commissioning instrument in an autonomous mode (no other parts of the VLTI involved); then the VLTI telescopes and optical trains will be tested in autocollimation; finally fringes will be observed on the sky.

  14. 2D and 3D optical diagnostic techniques applied to Madonna dei Fusi by Leonardo da Vinci

    NASA Astrophysics Data System (ADS)

    Fontana, R.; Gambino, M. C.; Greco, M.; Marras, L.; Materazzi, M.; Pampaloni, E.; Pelagotti, A.; Pezzati, L.; Poggi, P.; Sanapo, C.

    2005-06-01

    3D measurement and modelling have been traditionally applied to statues, buildings, archeological sites or similar large structures, but rarely to paintings. Recently, however, 3D measurements have been performed successfully also on easel paintings, allowing to detect and document the painting's surface. We used 3D models to integrate the results of various 2D imaging techniques on a common reference frame. These applications show how the 3D shape information, complemented with 2D colour maps as well as with other types of sensory data, provide the most interesting information. The 3D data acquisition was carried out by means of two devices: a high-resolution laser micro-profilometer, composed of a commercial distance meter mounted on a scanning device, and a laser-line scanner. The 2D data acquisitions were carried out using a scanning device for simultaneous RGB colour imaging and IR reflectography, and a UV fluorescence multispectral image acquisition system. We present here the results of the techniques described, applied to the analysis of an important painting of the Italian Reinassance: `Madonna dei Fusi', attributed to Leonardo da Vinci.

  15. The oldest anatomical handmade skull of the world c. 1508: 'the ugliness of growing old' attributed to Leonardo da Vinci.

    PubMed

    Missinne, Stefaan J

    2014-06-01

    The author discusses a previously unknown early sixteenth-century renaissance handmade anatomical miniature skull. The small, naturalistic skull made from an agate (calcedonia) stone mixture (mistioni) shows remarkable osteologic details. Dr. Saban was the first to link the skull to Leonardo. The three-dimensional perspective of and the search for the senso comune are discussed. Anatomical errors both in the drawings of Leonardo and this skull are presented. The article ends with the issue of physiognomy, his grotesque faces, the Perspective Communis and his experimenting c. 1508 with the stone mixture and the human skull. Evidence, including the Italian scale based on Crazie and Braccia, chemical analysis leading to a mine in Volterra and Leonardo's search for the soul in the skull are presented. Written references in the inventory of Salai (1524), the inventory of the Villa Riposo (Raffaello Borghini 1584) and Don Ambrogio Mazenta (1635) are reviewed. The author attributes the skull c. 1508 to Leonardo da Vinci.

  16. Evaluation of different time schedules in training with the Da Vinci simulator.

    PubMed

    Güldner, C; Orth, A; Dworschak, P; Diogo, I; Mandapathil, M; Teymoortash, A; Walliczek-Dworschak, U

    2017-10-01

    This prospective study analyzed the effect of different time schedules in training on the main performance outcomes: overall score, time to complete, and economy of motion. The study was performed on the da Vinci Skills Simulator from December 2014 to April 2016. Forty robotic novices were randomized into two groups of 20 participants, which trained in the same three exercises but with different intervals between their training sessions. Each group performed training in Peg Board 1 in their first week, Match Board 2 in their second week, and Ring and Rail 2 in their third week. On their last day, Needle Targeting and Energy Dissection 2, for which no previous training had been received, were performed. Regarding the different training intervals, group 1 trained each exercise six times in a row once a week. Group 2 performed their training once a day for 5 days. Technical performance parameters were recorded by the Mimics simulator software for further analysis. In addition, the participants were asked to fill out a questionnaire concerning the robotics training. Group 2 performed significantly better compared to group 1 in the main metrics in the more advanced exercises. For the easier exercises, the training frequency did not lead to significant differences in performance outcome. A significant skills gain was seen between the first and last training sessions for all exercises in both groups. Performance in the final exercise NT was significantly better in group 2 than group 1. Regarding ED 2, no difference was found between the two groups. As the training of group 2 led to significantly better outcomes, we suggest that, especially for advanced exercises, it seems to be more favorable to perform training every day for a short period than to train once a week six times in a row.

  17. Unfolding Leonardo DA Vinci's Globe (ad 1504) to Reveal its Historical World Map

    NASA Astrophysics Data System (ADS)

    Verhoeven, G. J.; Missinne, S. J.

    2017-08-01

    This paper reports in detail on the image-based modelling and unwrapping approach used to create a two-dimensional projected map of an astonishing ostrich egg globe from AD 1504. This miniature egg globe is not only the oldest extant engraved globe, but it is also the oldest post-Columbian globe of the world and the first ever to depict Newfoundland and many other territories. The intention of digitally recording the surface geometry and colour of this unique artefact was to portray the original layout of the world map used by the Florentine Renaissance artist to make this globe. In addition, it was expected to substantiate iconographical details, which are hard to study at its scale of 1:80,000,000. The ostrich egg globe is the prototype of the Lenox Globe kept at the New York Public Library. The latter is very beneficial to examine how the egg globe looked like before being glued together at its equator. On the other hand, unfolding the map engraved in the ostrich egg halves enables a more detailed study of the remarkable details visible on both globes, since the engravings on the quasi-white egg surface are much easier to discern than those of the highly reflective red copper Lenox Globe. Finally, a detailed study of the unwrapped 3D surface is essential to learn more about the world vision of its creator and the incredible efforts that went into making this globe. Thanks to some particular pictographic details as well as the way in which the engravings are applied (by a left-handed person), the globe artist can be identified as Leonardo da Vinci.

  18. A psychoanalytic understanding of the desire for knowledge as reflected in Freud's Leonardo da Vinci and a memory of his childhood.

    PubMed

    Blass, Rachel B

    2006-10-01

    The author offers an understanding of the psychoanalytic notion of the desire for knowledge and the possibility of attaining it as it fi nds expression in Freud's Leonardo da Vinci and a memory of his childhood. This understanding has not been explicitly articulated by Freud but may be considered integral to psychoanalysis' Weltanschauung as shaped by Freud's legacy. It emerges through an attempt to explain basic shifts, contradictions, inconsistencies and tensions that become apparent from a close reading of the text of Leonardo. Articulating this implicit understanding of knowledge provides the grounds for a stance on epistemology that is integral to psychoanalysis and relevant to contemporary psychoanalytic concerns on this topic. This epistemology focuses on the necessary involvement of passion, rather than detachment, in the search for knowledge and views the psychoanalytic aim of self-knowledge as a derivative, and most immediate expression, of a broader and more basic human drive to know.

  19. Reforming Upper Secondary Education in Europe. The Leonardo da Vinci Project Post-16 Strategies. Surveys of Strategies for Post-16 Education To Improve the Parity of Esteem for Initial Vocational Education in Eight European Educational Systems. Theory into Practice 92. Institute for Educational Research Publication Series B.

    ERIC Educational Resources Information Center

    Lasonen, Johanna, Ed.

    This book contains the following papers on the Leonardo da Vinci project: "Looking for Post-16 Education Strategies for Parity of Esteem in Europe" (Lasonen); "Improving Parity of Esteem as a Policy Goal" (Makinen, Volanen); "Alternative Strategies for Parity of Esteem between General/Academic and Vocational Education in…

  20. A review of training research and virtual reality simulators for the da Vinci surgical system.

    PubMed

    Liu, May; Curet, Myriam

    2015-01-01

    PHENOMENON: Virtual reality simulators are the subject of several recent studies of skills training for robot-assisted surgery. Yet no consensus exists regarding what a core skill set comprises or how to measure skill performance. Defining a core skill set and relevant metrics would help surgical educators evaluate different simulators. This review draws from published research to propose a core technical skill set for using the da Vinci surgeon console. Publications on three commercial simulators were used to evaluate the simulators' content addressing these skills and associated metrics. An analysis of published research suggests that a core technical skill set for operating the surgeon console includes bimanual wristed manipulation, camera control, master clutching to manage hand position, use of third instrument arm, activating energy sources, appropriate depth perception, and awareness of forces applied by instruments. Validity studies of three commercial virtual reality simulators for robot-assisted surgery suggest that all three have comparable content and metrics. However, none have comprehensive content and metrics for all core skills. INSIGHTS: Virtual reality simulation remains a promising tool to support skill training for robot-assisted surgery, yet existing commercial simulator content is inadequate for performing and assessing a comprehensive basic skill set. The results of this evaluation help identify opportunities and challenges that exist for future developments in virtual reality simulation for robot-assisted surgery. Specifically, the inclusion of educational experts in the development cycle alongside clinical and technological experts is recommended.

  1. Instrument Failures for the da Vinci Surgical System: a Food and Drug Administration MAUDE Database Study.

    PubMed

    Friedman, Diana C W; Lendvay, Thomas S; Hannaford, Blake

    2013-05-01

    Our goal was to analyze reported instances of the da Vinci robotic surgical system instrument failures using the FDA's MAUDE (Manufacturer and User Facility Device Experience) database. From these data we identified some root causes of failures as well as trends that may assist surgeons and users of the robotic technology. We conducted a survey of the MAUDE database and tallied robotic instrument failures that occurred between January 2009 and December 2010. We categorized failures into five main groups (cautery, shaft, wrist or tool tip, cable, and control housing) based on technical differences in instrument design and function. A total of 565 instrument failures were documented through 528 reports. The majority of failures (285) were of the instrument's wrist or tool tip. Cautery problems comprised 174 failures, 76 were shaft failures, 29 were cable failures, and 7 were control housing failures. Of the reports, 10 had no discernible failure mode and 49 exhibited multiple failures. The data show that a number of robotic instrument failures occurred in a short period of time. In reality, many instrument failures may go unreported, thus a true failure rate cannot be determined from these data. However, education of hospital administrators, operating room staff, surgeons, and patients should be incorporated into discussions regarding the introduction and utilization of robotic technology. We recommend institutions incorporate standard failure reporting policies so that the community of robotic surgery companies and surgeons can improve on existing technologies for optimal patient safety and outcomes.

  2. Combining of ETHOS Operating Ergonomic Platform, Three-dimensional Laparoscopic Camera, and Radius Surgical System Manipulators Improves Ergonomy in Urologic Laparoscopy: Comparison with Conventional Laparoscopy and da Vinci in a Pelvi Trainer.

    PubMed

    Tokas, Theodoros; Gözen, Ali Serdar; Avgeris, Margaritis; Tschada, Alexandra; Fiedler, Marcel; Klein, Jan; Rassweiler, Jens

    2017-10-01

    Posture, vision, and instrumentation limitations are the main predicaments of conventional laparoscopy. To combine the ETHOS surgical chair, the three-dimensional laparoscope, and the Radius Surgical System manipulators, and compare the system with conventional laparoscopy and da Vinci in terms of task completion times and discomfort. Fifteen trainees performed the three main laparoscopic suturing tasks of the Heilbronn training program (IV: simulation of dorsal venous complex suturing; V: circular suturing of tubular structure; and VI: urethrovesical anastomosis) in a pelvi trainer. The tasks were performed conventionally, utilizing the three devices, and robotically. Task completion times were recorded and the surgeon discomfort was evaluated using questionnaires. Task completion times were compared using nonparametric Wilcoxon signed rank test and ergonomic scores were compared using Pearson chi-square test. The use of the full laparoscopic set (ETHOS chair, three-dimensional laparoscopic camera, Radius Surgical System needle holders), resulted in a significant improvement of the completion time of the three tested tasks compared with conventional laparoscopy (p<0.001) and similar to da Vinci surgery. After completing Tasks IV, V, and VI conventionally, 12 (80%), 13 (86.7%), and 13 (86.7%) of the 15 trainees, respectively, reported heavy total discomfort. The full laparoscopic system nullified heavy discomfort for Tasks IV and V and minimized it (6.7%) for the most demanding Task VI. Especially for Task VI, all trainees gained benefit, by using the system, in terms of task completion times and discomfort. The limited trainee robotic experience and the questionnaire subjectivity could be a potential limitation. The ergonomic laparoscopic system offers significantly improved task completion times and ergonomy than conventional laparoscopy. Furthermore, it demonstrates comparable results to robotic surgery. The study was conducted in a pelvi trainer and no patients

  3. Validation of the da Vinci Surgical Skill Simulator across three surgical disciplines: A pilot study

    PubMed Central

    Alzahrani, Tarek; Haddad, Richard; Alkhayal, Abdullah; Delisle, Josée; Drudi, Laura; Gotlieb, Walter; Fraser, Shannon; Bergman, Simon; Bladou, Frank; Andonian, Sero; Anidjar, Maurice

    2013-01-01

    Objective: In this paper, we evaluate face, content and construct validity of the da Vinci Surgical Skills Simulator (dVSSS) across 3 surgical disciplines. Methods: In total, 48 participants from urology, gynecology and general surgery participated in the study as novices (0 robotic cases performed), intermediates (1–74) or experts (≥75). Each participant completed 9 tasks (Peg board level 2, match board level 2, needle targeting, ring and rail level 2, dots and needles level 1, suture sponge level 2, energy dissection level 1, ring walk level 3 and tubes). The Mimic Technologies software scored each task from 0 (worst) to 100 (best) using several predetermined metrics. Face and content validity were evaluated by a questionnaire administered after task completion. Wilcoxon test was used to perform pair wise comparisons. Results: The expert group comprised of 6 attending surgeons. The intermediate group included 4 attending surgeons, 3 fellows and 5 residents. The novices included 1 attending surgeon, 1 fellow, 13 residents, 13 medical students and 2 research assistants. The median number of robotic cases performed by experts and intermediates were 250 and 9, respectively. The median overall realistic score (face validity) was 8/10. Experts rated the usefulness of the simulator as a training tool for residents (content validity) as 8.5/10. For construct validity, experts outperformed novices in all 9 tasks (p < 0.05). Intermediates outperformed novices in 7 of 9 tasks (p < 0.05); there were no significant differences in the energy dissection and ring walk tasks. Finally, experts scored significantly better than intermediates in only 3 of 9 tasks (matchboard, dots and needles and energy dissection) (p < 0.05). Conclusions: This study confirms the face, content and construct validities of the dVSSS across urology, gynecology and general surgery. Larger sample size and more complex tasks are needed to further differentiate intermediates from experts. PMID:23914275

  4. The effect of different training exercises on the performance outcome on the da Vinci Skills Simulator.

    PubMed

    Walliczek-Dworschak, U; Schmitt, M; Dworschak, P; Diogo, I; Ecke, A; Mandapathil, M; Teymoortash, A; Güldner, C

    2017-06-01

    Increasing usage of robotic surgery presents surgeons with the question of how to acquire the special skills required. This study aimed to analyze the effect of different exercises on their performance outcomes. This prospective study was conducted on the da Vinci Skills Simulator from December 2014 till August 2015. Sixty robotic novices were included and randomized to three groups of 20 participants each. Each group performed three different exercises with comparable difficulty levels. The exercises were performed three times in a row within two training sessions, with an interval of 1 week in between. On the final training day, two new exercises were added and a questionnaire was completed. Technical metrics of performance (overall score, time to complete, economy of motion, instrument collisions, excessive instrument force, instruments out of view, master work space range, drops, missed targets, misapplied energy time, blood loss and broken vessels) were recorded by the simulator software for further analysis. Training with different exercises led to comparable results in performance metrics for the final exercises among the three groups. A significant skills gain was recorded between the first and last exercises, with improved performance in overall score, time to complete and economy of motion for all exercises in all three groups. As training with different exercises led to comparable results in robotic training, the type of exercise seems to play a minor role in the outcome. For a robotic training curriculum, it might be important to choose exercises with comparable difficulty levels. In addition, it seems to be advantageous to limit the duration of the training to maintain the concentration throughout the entire session.

  5. Peri-operative comparison between daVinci-assisted radical prostatectomy and open radical prostatectomy in obese patients

    NASA Astrophysics Data System (ADS)

    Le, Carter Q.; Ho, Khai-Linh V.; Slezak, Jeffrey M.; Blute, Michael L.; Gettman, Matthew T.

    2007-02-01

    Introduction: While the effects of increasing body mass index on prostate cancer epidemiology and surgical approach have recently been studied, its effects on surgical outcomes are less clear. We studied the perioperative outcomes of obese (BMI >= 30) men treated with daVinci-assisted laparoscopic radical prostatectomy (DLP) and compared them to those treated with open radical retropubic prostatectomy (RRP) in a contemporary time frame. Method: After Institutional Review Board approval, we used the Mayo Clinic Radical Prostatectomy database to identify patients who had undergone DLP by a single surgeon and those who had undergone open RRP by a single surgeon between December 2002 and March 2005. Baseline demographics, peri- and post-operative courses, and complications were collected by retrospective chart review, and variables from the two cohorts compared using chi-square method and least-squares method of linear regression where appropriate. Results: 59 patients who had DLP and 76 undergoing RRP were available for study. Baseline demographics were not statistically different between the two cohorts. Although DLP had a significantly lower clinical stage than RRP (p=0.02), pathological stage was not statistically different (p=0.10). Transfusion rates, hospital stay, overall complications, and pathological Gleason were also not significantly different, nor were PSA progression, positive margin rate, or continence at 1 year. After bilateral nerve-sparing, erections suitable for intercourse with or without therapy at 1 year was 88.5% (23/26) for DLP and 61.2% (30/49) for RRP (p=0.01). Follow-up time was similar. Conclusion: For obese patients, DLP appears to have similar perioperative, as well as short-term oncologic and functional outcomes when compared to open RRP.

  6. Amid the possible causes of a very famous foxing: molecular and microscopic insight into Leonardo da Vinci's self-portrait.

    PubMed

    Piñar, Guadalupe; Tafer, Hakim; Sterflinger, Katja; Pinzari, Flavia

    2015-12-01

    Leonardo da Vinci's self-portrait is affected by foxing spots. The portrait has no fungal or bacterial infections in place, but is contaminated with airborne spores and fungal material that could play a role in its disfigurement. The knowledge of the nature of the stains is of great concern because future conservation treatments should be derived from scientific investigations. The lack of reliable scientific data, due to the non-culturability of the microorganisms inhabiting the portrait, prompted the investigation of the drawing using non-invasive and micro-invasive sampling, in combination with scanning electron microscope (SEM) imaging and molecular techniques. The fungus Eurotium halophilicum was found in foxing spots using SEM analyses. Oxalates of fungal origin were also documented. Both findings are consistent with the hypothesis that tonophilic fungi germinate on paper metabolizing organic acids, oligosaccharides and proteic compounds, which react chemically with the material at a low water activity, forming brown products and oxidative reactions resulting in foxing spots. Additionally, molecular techniques enabled a screening of the fungi inhabiting the portrait and showed differences when different sampling techniques were employed. Swabs samples showed a high abundance of lichenized Ascomycota, while the membrane filters showed a dominance of Acremonium sp. colonizing the drawing. © 2015 The Authors. Environmental Microbiology Reports published by Society for Applied Microbiology and John Wiley & Sons Ltd.

  7. MONA, LISA and VINCI Soon Ready to Travel to Paranal

    NASA Astrophysics Data System (ADS)

    2000-11-01

    First Instruments for the VLT Interferometer Summary A few months from now, light from celestial objects will be directed for the first time towards ESO's Very Large Telescope Interferometer (VLTI) at the Paranal Observatory (Chile). During this "First Light" event and the subsequent test phase, the light will be recorded with a special test instrument, VINCI (VLT INterferometer Commissioning Instrument). The main components of this high-tech instrument are aptly named MONA (a system that combines the light beams from several telescopes by means of optical fibers) and LISA (the infrared camera). VINCI was designed and constructed within a fruitful collaboration between ESO and several research institutes and industrial companies in France and Germany . It is now being assembled at the ESO Headquarters in Garching (Germany) and will soon be ready for installation at the telescope on Paranal. With the VLTI and VINCI, Europe's astronomers are now entering the first, crucial phase of an exciting scientific and technology venture that will ultimately put the world's most powerful optical/IR interferometric facility in their hands . PR Photo 31/00 : VINCI during tests at the ESO Headquarters in Garching. The VLT Interferometer (VLTI) ESO Press Photo 31/00 ESO Press Photo 31/00 [Preview; JPEG: 400 x 301; 43k] [Normal; JPEG: 800 x 602;208xk] [Full-Res; JPEG: 1923 x 1448; 2.2Mb] PR Photo 31/00 shows the various components of the complex VINCI instrument for the VLT Interferometer , during the current tests at the Optical Laboratory at the ESO Headquarters in Garching (Germany). It will later be installed in "clean-room" conditions within the Interferometric Laboratory at the Paranal Observatory. This electronic photo was obtained for documentary purposes. VINCI (VLT INterferometer Commissioning Instrument) is the "First Light" instrument for the Very Large Telescope Interferometer (VLTI) at the Paranal Observatory (Chile). Early in 2001, it will be used for the first tests

  8. [Application of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy].

    PubMed

    Yang, Kun; Chen, Xinzu; Zhang, Weihan; Chen, Xiaolong; Hu, Jiankun

    2016-08-25

    To investigate the feasibility and safety of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy. Clinical data of two cases who underwent total gastrectomy for cardia cancer at our department in January 2016 were analyzed retrospectively. Two male patients were 62 and 55 years old respectively, with preoperative diagnosis as cT2-3N0M0 and cT1-2N0M0 gastric cancer by gastroscope and biopsy, and both received robotic total gastrectomy spleen-preserving splenic hilar lymph node dissection successfully. The operative time for splenic hilar lymph node dissection was 30 min and 25 min respectively. The intraoperative estimated blood loss was both 100 ml, while the number of total harvested lymph node was 38 and 33 respectively. One dissected splenic hilar lymph node and fatty tissues in two patients were proven by pathological examinations. There were no anastomotic leakage, pancreatic fistula, splenic infarction, intraluminal bleeding, digestive tract bleeding, aneurysm of splenic artery, and other operation-associated complications. Both patients suffered from postoperative pneumonia, and were cured by conservative therapy. The robotic spleen-preserving splenic hilar lymph node dissection is feasible and safe, but its superiority needs further evaluation.

  9. The da vinci robot system eliminates multispecialty surgical trainees' hand dominance in open and robotic surgical settings.

    PubMed

    Badalato, Gina M; Shapiro, Edan; Rothberg, Michael B; Bergman, Ari; RoyChoudhury, Arindam; Korets, Ruslan; Patel, Trushar; Badani, Ketan K

    2014-01-01

    Handedness, or the inherent dominance of one hand's dexterity over the other's, is a factor in open surgery but has an unknown importance in robot-assisted surgery. We sought to examine whether the robotic surgery platform could eliminate the effect of inherent hand preference. Residents from the Urology and Obstetrics/Gynecology departments were enrolled. Ambidextrous and left-handed subjects were excluded. After completing a questionnaire, subjects performed three tasks modified from the Fundamentals of Laparoscopic Surgery curriculum. Tasks were performed by hand and then with the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, California). Participants were randomized to begin with using either the left or the right hand, and then switch. Left:right ratios were calculated from scores based on time to task completion. Linear regression analysis was used to determine the significance of the impact of surgical technique on hand dominance. Ten subjects were enrolled. The mean difference in raw score performance between the right and left hands was 12.5 seconds for open tasks and 8 seconds for robotic tasks (P<.05). Overall left-right ratios were found to be 1.45 versus 1.12 for the open and robot tasks, respectively (P<.05). Handedness significantly differed between robotic and open approaches for raw time scores (P<.0001) and left-right ratio (P=.03) when controlling for the prior tasks completed, starting hand, prior robotic experience, and comfort level. These findings remain to be validated in larger cohorts. The robotic technique reduces hand dominance in surgical trainees across all task domains. This finding contributes to the known advantages of robotic surgery.

  10. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    PubMed Central

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  11. [The Da Vinci Medical-mental motivation program for supporting lifestyle changes in patients with type 2 diabetes].

    PubMed

    Kempf, K; Dirk, M; Kolb, H; Hebestreit, A; Bittner, G; Martin, S

    2012-02-01

    Healthy diet and physical activity can improve metabolic control in patients with type 2 diabetes mellitus. However, lifestyle change without external help is difficult: an alteration of mental attitude is necessary to achieve long-term success. A computer-based motivational program ("Da Vinci") has been developed to help patients to change their mental attitudes and beliefs. Patients with type 2 diabetes were supervised by psychological trainers in four sessions at ten study centers. The interactive computer program allowed for identification of motivation restraints and overcoming them. Parameters of carbohydrate metabolism were measured at the beginning and end of the three-months program as well as three and six months after end of program. All participants (n = 61) developed a positive attitude towards the range of their action and by themselves changed their lifestyle. After three months their weight (-4.6 kg; p < 0.0001), body mass index (-1.1 kg/m2; p < 0.0001), waist circumference (-3.5 cm; p < 0.0001), HbA1c (-0.6 %; p < 0.0001), triglycerides (-31.1 mg/dl; p = 0.033), systolic (-4.0 mmHg; p = 0.005) and diastolic blood pressure (-3.0 mmHg; p = 0.006) had been reduced. Short duration of diabetes and high baseline HbA1c values were predictive for successful HbA1c reduction. Three and six months after end of the program participants were able to maintain or even augment achieved improvements. During the motivational program, which is intended to alter mental attitude and beliefs, but not to teach knowledge about diabetes, participants were able to significantly improve their metabolic control. As these improvements were maintained long-term, this points to sustainable lifestyle change. © Georg Thieme Verlag KG Stuttgart · New York.

  12. How did Leonardo perceive himself? Metric iconography of da Vinci's self-portraits

    NASA Astrophysics Data System (ADS)

    Tyler, Christopher W.

    2010-02-01

    Some eighteen portraits are now recognized of Leonardo in old age, consolidating the impression from his bestestablished self-portrait of an old man with long white hair and beard. However, his appearance when younger is generally regarded as unknown, although he was described as very beautiful as a youth. Application of the principles of metric iconography, the study of the quantitative analysis of the painted images, provides an avenue for the identification of other portraits that may be proposed as valid portraits of Leonardo during various stages of his life, by himself and by his contemporaries. Overall, this approach identifies portraits of Leonardo by Verrocchio, Raphael, Botticelli, and others. Beyond this physiognomic analysis, Leonardo's first known drawing provides further insight into his core motivations. Topographic considerations make clear that the drawing is of the hills behind Vinci with a view overlooking the rocky promontory of the town and the plain stretching out before it. The outcroppings in the foreground bear a striking resemblance to those of his unique composition, 'The Virgin of the Rocks', suggesting a deep childhood appreciation of this wild terrain. and an identification with that religious man of the mountains, John the Baptist, who was also the topic of Leonardo's last known painting. Following this trail leads to a line of possible selfportraits continuing the age-regression concept back to a self view at about two years of age.

  13. A novel robotic right colectomy for colon cancer via the suprapubic approach using the da Vinci Xi system: initial clinical experience

    PubMed Central

    Lee, Hee Jae; Park, Jun Seok; Park, Soo Yeun; Kim, Hye Jin; Woo, In Teak; Park, In Kyu

    2018-01-01

    Purpose We developed a technique of totally-robotic right colectomy with D3 lymphadenectomy and intracorporeal anastomosis via a suprapubic transverse linear port. This article aimed to introduce our novel robotic surgical technique and assess the short-term outcomes in a series of five patients. Methods All colectomies were performed using the da Vinci Xi system. Four robot trocars were placed transversely in the supra pubic area. Totally-robotic right colectomy was performed, including colonic mobilization, D3 lymphadenectomy, and intra corporeal stapled functional anastomosis. The 2 middle suprapubic trocar incisions were then extended to retrieve the specimen. Results Five robotic right colectomies via the suprapubic approach were performed between August 2015 and February 2016. The mean operation time was 183 ± 29.37 minutes, and the mean estimated blood loss was 27 ± 9.75 mL. The time to clear liquid intake was 3 days in all patients, and the mean length of stay after surgery was 6.2 ± 0.55 days. No patient required conversion to conventional laparoscopic surgery. There were no perioperative complications. According to the pathology report, the mean number of harvested lymph nodes was 36.6 ± 4.45. Four patients were stage III, and 1 patient was stage II according to the 7th edition of the American Joint Committee on Cancer system. Conclusion Totally-robotic right colectomy via the suprapubic approach can be performed successfully in selected patients. Further comparative studies are required to verify the clinical advantages of our technique over conventional robotic surgery. PMID:29441337

  14. Particle Size Control for PIV Seeding Using Dry Ice

    DTIC Science & Technology

    2010-03-01

    in flight actually being carried out, the observations, drawings and notes of Leonardo da Vinci showed an analytical process to develop a way for...theoretical particle response: dvp dt = −C(vp − U) C = 18µ ρpd2p 86 87 Bibliography 1. Linscott, R. N. and Da Vinci , L., The Notebooks of Leonardo Da Vinci

  15. Cross Body Thruster Control and Modeling of a Body of Revolution Autonomous Underwater Vehicle

    DTIC Science & Technology

    2011-03-01

    Leonardo da Vinci envisioned submersible troop transports, assault craft, and diving rigs in the early sixteenth century. Figure 1. Da...BLOCK DIAGRAM 90 THIS PAGE INTENTIONALLY LEFT BLANK 91 LIST OF REFERENCES [1] Museo Galileo, “ Leonardo da Vinci – Studies on Keels of...appl=LIR&xsl=paginamanoscritto&li ngua=ENG&chiave=101406. [Accessed: 10 October 2010]. [2] Museo Galileo, “ Leonardo da Vinci – Machine for Raising

  16. Improved Image-Guided Laparoscopic Prostatectomy

    DTIC Science & Technology

    2011-08-01

    standard daVinci tool . The ultrasound probe is driven by a Sonix RP ultrasound system (Ultrasonix Medical Corp., Richmond BC Canada), which provides...probe (Intuitive Surgical, Sunnyvale, CA) was integrated with the daVinci surgical system for use in Robot-Assisted Laparoscopic Prostatectomy (RALP...laparoscopy using the daVinci Surgical System (Intuitive Surgical, Sunnyvale, CA). The surgical robot introduces many benefits, including three

  17. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    PubMed

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  18. Nanoparticle-Wetted Relays: Reconfigurable Surfaces for Energy Transmission Contacts

    DTIC Science & Technology

    2007-01-01

    in-situ monitoring of contact processes as described previously4,17. 9 1. Da Vinci , Leonardo . Madrid Codices, Manuscript I. Biblioteca Nacional...technologists from pre-Hellenistic pulleys and Da Vinci mechanisms for transmission of mechanical energy to modern switches and relays for...Hellenistic pulleys and Da Vinci mechanisms for transmission of mechanical energy1 to modern switches and relays for transmission of electrical energy

  19. Rethinking Traffic Management: Design of Optimizable Networks

    DTIC Science & Technology

    2008-06-01

    Though this paper used optimization theory to design and analyze DaVinci , op- timization theory is one of many possible tools to enable a grounded...dynamically allocate bandwidth shares. The distributed protocols can be implemented using DaVinci : Dynamically Adaptive VIrtual Networks for a Customized...Internet. In DaVinci , each virtual network runs traffic-management protocols optimized for a traffic class, and link bandwidth is dynamically allocated

  20. Comparative analysis of short - term functional outcomes and quality of life in a prospective series of brachytherapy and Da Vinci robotic prostatectomy

    PubMed Central

    García-Sánchez, Cristina; Román Martín, Ana A.; Conde-Sánchez, J. Manuel; Congregado-Ruíz, C. Belén; Osman-García, Ignacio; Medina-López, Rafael A.

    2017-01-01

    ABSTRACT Introduction There is a growing interest in achieving higher survival rates with the lowest morbidity in localized prostate cancer (PC) treatment. Consequently, minimally invasive techniques such as low-dose rate brachytherapy (BT) and robotic-assisted prostatectomy (RALP) have been developed and improved. Comparative analysis of functional outcomes and quality of life in a prospective series of 51BT and 42Da Vinci prostatectomies DV Materials and Methods Comparative analysis of functional outcomes and quality of life in a prospective series of 93 patients with low-risk localized PC diagnosed in 2011. 51patients underwent low-dose rate BT and the other 42 patients RALP. IIEF to assess erectile function, ICIQ to evaluate continence and SF36 test to quality of life wee employed. Results ICIQ at the first revision shows significant differences which favour the BT group, 79% present with continence or mild incontinence, whereas in the DV group 45% show these positive results. Differences disappear after 6 months, with 45 patients (89%) presenting with continence or mild incontinence in the BT group vs. 30 (71%) in the DV group. 65% of patients are potent in the first revision following BT and 39% following DV. Such differences are not significant and cannot be observed after 6 months. No significant differences were found in the comparative analysis of quality of life. Conclusions ICIQ after surgery shows significant differences in favour of BT, which disappear after 6 months. Both procedures have a serious impact on erectile function, being even greater in the DV group. Differences between groups disappear after 6 months. PMID:28128908

  1. Single-cycle Pulse Synthesis by Coherent Superposition of Ultra-broadband Optical Parametric Amplifiers

    DTIC Science & Technology

    2011-08-01

    Giulio Cerullo Politecnico di Milano Department of Physics Piazza Leonardo da Vinci 32 Milano, Italy 20133 EOARD GRANT 09-3101...UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Politecnico di Milano Department of Physics Piazza Leonardo da Vinci 32 Milano...Milano, Piazza L. Da Vinci 32, 20133 Milano, Italy, 4DESY-Center for Free-Electron Laser Science and Hamburg University, Notkestraße 85, D-22607 Hamburg

  2. Anion-Driven Self-Assembly Processes Based on Halogen-Bonding

    DTIC Science & Technology

    2007-07-10

    23993041 Fax: +39-02-23993180 E-mail: pierangelo.metrangolo@polimi.it Sede Leonardo : Piazza L.Da Vinci , 32 – 20133 Milano Tel. ++39-02...02-23993180 E-mail: pierangelo.metrangolo@polimi.it Sede Leonardo : Piazza L.Da Vinci , 32 – 20133 Milano Tel. ++39-02 2399.3200 Fax ++39-02...Pierangelo Metrangolo Ph. +39-02-23993041 Fax: +39-02-23993180 E-mail: pierangelo.metrangolo@polimi.it Sede Leonardo : Piazza L.Da Vinci , 32

  3. Comparison of two simulation systems to support robotic-assisted surgical training: a pilot study (Swine model).

    PubMed

    Whitehurst, Sabrina V; Lockrow, Ernest G; Lendvay, Thomas S; Propst, Anthony M; Dunlow, Susan G; Rosemeyer, Christopher J; Gobern, Joseph M; White, Lee W; Skinner, Anna; Buller, Jerome L

    2015-01-01

    To compare the efficacy of simulation-based training between the Mimic dV- Trainer and traditional dry lab da Vinci robot training. A prospective randomized study analyzing the performance of 20 robotics-naive participants. Participants were enrolled in an online da Vinci Intuitive Surgical didactic training module, followed by training in use of the da Vinci standard surgical robot. Spatial ability tests were performed as well. Participants were randomly assigned to 1 of 2 training conditions: performance of 3 Fundamentals of Laparoscopic Surgery dry lab tasks using the da Vinci or performance of 4 dV-Trainer tasks. Participants in both groups performed all tasks to empirically establish proficiency criterion. Participants then performed the transfer task, a cystotomy closure using the daVinci robot on a live animal (swine) model. The performance of robotic tasks was blindly assessed by a panel of experienced surgeons using objective tracking data and using the validated Global Evaluative Assessment of Robotic Surgery (GEARS), a structured assessment tool. No statistically significant difference in surgeon performance was found between the 2 training conditions, dV-Trainer and da Vinci robot. Analysis of a 95% confidence interval for the difference in means (-0.803 to 0.543) indicated that the 2 methods are unlikely to differ to an extent that would be clinically meaningful. Based on the results of this study, a curriculum on the dV- Trainer was shown to be comparable to traditional da Vinci robot training. Therefore, we have identified that training on a virtual reality system may be an alternative to live animal training for future robotic surgeons. Published by Elsevier Inc.

  4. Multi-Model Validation in the Chesapeake Bay Region During Frontier Sentinel 2010

    DTIC Science & Technology

    2012-09-28

    which a 72-hr forecast took approximately 1 hr. Identical runs were performed on the DoD Supercomputing Resources Center (DSRC) host “ DaVinci ” at the...performance Navy DSRC host DaVinci . Products of water level and horizontal current maps as well as station time series, identical to those produced by the...forecast meteorological fields. The NCOM simulations were run daily on 128 CPUs at the Navy DSRC host DaVinci and required approximately 5 hrs of wall

  5. Multi-Model Validation of Currents in the Chesapeake Bay Region in June 2010

    DTIC Science & Technology

    2012-01-01

    host “ DaVinci ” at the Naval Oceanographic Office (NAVOCEANO). The same model configuration also took approximately 1 hr of wall clock time for a 72-hr...comparable to the performance Navy DSRC host DaVinci . Products of water level and horizontal current maps as well as station time series, identical to...DSRC host DaVinci and required approximately 5 hrs of wall-clock time for 72-hr forecasts, including data Figure 10. The Chesapeake Bay Delft3D

  6. A new view of particle physics

    NASA Astrophysics Data System (ADS)

    Medeiros, João

    2008-11-01

    Long before C P Snow's two cultures, there was only one. Its supreme embodiment was the great Renaissance master Leonardo da Vinci. Da Vinci saw no barriers between art and science (or what was known as natural philosophy back in the 16th century). His journals were filled with sketches, ideas and observations that testify to the polymath nature of Da Vinci's ingenuity. Da Vinci used artistic inspiration as a path to his inventions, and the observation of the natural world as an intrinsically artistic undertaking. He made thousands of blueprints outlining some of the most impressive inventions ever conceptualized - flying machines, bridges, calculators, tanks, solar-power cells. Most were impractical, few every saw the light of day, but all bore the mark of the master's infinite inventive powers.

  7. Change of practice patterns in urology with the introduction of the Da Vinci surgical system: the Greek NHS experience in debt crisis era.

    PubMed

    Deligiannis, Dimitros; Anastasiou, Ioannis; Mygdalis, Vasileios; Fragkiadis, Evangelos; Stravodimos, Konstantinos

    2015-03-31

    To determine the attitudinal change for urologic surgery in Greece since the introduction of the da Vinci Surgical System (DVS). We describe contemporary trends at public hospital level, the initial Greek experience, while at the same time Greece is in economic crisis and funding is under austerity measures. We retrospectively analyzed annualized case log data on urologic procedures, between 2008 (installation of the DVS) and 2013, from "Laiko'' Hospital in Athens. We evaluated, using summary statistics, trends and institutional status regarding robot-assisted surgery (RAS). We also analyzed the relationship between the introduction of RAS and change in total volume of procedures performed. 1578 of the urological procedures performed at "Laiko'' Hospital were pooled, 1342 (85%) being open and 236 RAS (15%). We observed a 6-fold increase in the number of RAS performed, from 7% of the total procedural volume (14/212) in 2008 to 30% (96/331) in 2013. For radical prostatectomy, in 2008 2% were robot-assisted and 98% open while in 2013, 46% and 54% respectively. Pyeloplasty was performed more often using the robot-assisted method since 2010. RAS-dedicated surgeons increased both RAS and the total number of procedures they performed. From 86 in 2008 to 145 in 2013, with 57% of them being RAS in 2013 as compared to 13 % in 2008. Robot-assisted surgery has integrated into the armamentarium for urologic surgery in Greece at public hospital level. Surgical robot acquisition is also associated with increased volume of procedures, especially prostatectomy, despite the ongoing debate over cost-effectiveness, during economic crisis and International Monetary Fund (IFN) era.

  8. Estimating Anthropometric Marker Locations from 3-D LADAR Point Clouds

    DTIC Science & Technology

    2011-06-01

    http://perception.inrialpes. fr/Publications/2008/CMKBH08. [17] Da Vinci , L. The Notebooks of Leonardo Da Vinci Complete. Public Domain, 2004. [18] Duda...the problem is based on historical research into the proper proportioning of the human body. A famous example of this research is Leonardo da Vinci’s

  9. Introduction to Kinetic Model Equations

    DTIC Science & Technology

    2011-01-01

    application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 ∗Dipartimento di Matematica del Politecnico di Milano Piazza Leonardo da Vinci 32...NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Dipartimento di Matematica del Politecnico di Milano Piazza Leonardo da Vinci 32, 20133 Milano

  10. Clip and Save.

    ERIC Educational Resources Information Center

    Hubbard, Guy

    2003-01-01

    Focuses on the facial expression in the "Mona Lisa" by Leonardo da Vinci. Offers background information on da Vinci as well as learning activities for students. Includes a reproduction of the "Mona Lisa" and information about the painting. (CMK)

  11. Opto-Electronic and Interconnects Hierarchical Design Automation System (OE-IDEAS)

    DTIC Science & Technology

    2004-05-01

    NETBOOK WEBSITE............................................................71 8.2 SIMULATION OF CRITICAL PATH FROM THE MAYO “10G” SYSTEM MCM BOARD...Benchmarks from the DaVinci Netbook website In May 2002, CFDRC downloaded all the materials from the DaVinci Netbook website containing the benchmark

  12. Dynamics of Structural Phase Transformations Using Molecular Dynamics

    DTIC Science & Technology

    2013-12-08

    Investigator AFOSR Young Investigator ASCE Leonardo Da Vinci Young Investigator Award Eshelby Mechanics Award for Young Faculty 01/06/2011...Investigator Awards • Junior chair from Carnegie Mellon University, 2013-2016 • ASCE Engineering Mechanics Leonardo Da Vinci Early Career Award, 2013

  13. Totally extraperitoneal (TEP) bilateral hernioplasty using the Single Site® robotic da Vinci platform (DV-SS TEP): description of the technique and preliminary results.

    PubMed

    Cestari, A; Galli, A C; Sangalli, M N; Zanoni, M; Ferrari, M; Roviaro, G

    2017-06-01

    Laparoendoscopic single site totally extraperitoneal (TEP) hernia repair showed to be a feasible alternative to conventional laparoscopic hernia repair; nevertheless single site surgery, with the loss of instruments triangulation can be a demanding procedure. To overcome those hurdles, the Single Site® (SS) platform of the da Vinci (DV) Si robotic system enables to perform surgical procedures through a 25-mm skin incision, with a stable 3D vision and restoring an adequate triangulation of the surgical instruments. We present in details the technique and the preliminary results of DV-SS TEP, to our knowledge the first cases reported in literature. In March 2016, three consecutive male patients (mean age 46.6 years-mean BMI 25.3) with bilateral symptomatic inguinal hernia were submitted to DV-SS TEP in our institutions. Feasibility, codification of the technique, operative time and perioperative outcomes were recorded. All the procedures were completed as scheduled, with no conversion to other techniques. Mean operative time was 98.6 min, ranging between 155 and 55 min, reflecting the learning curve of the operating room team on this new procedure. No intraoperative or postoperative complications were experienced and all the patients were discharged within 24 h after surgery. Patients reported satisfactory postoperative course, with no recurrence of inguinal hernia and satisfaction in cosmetic result at 6-month follow-up. DV-SS TEP inguinal hernia repair showed to be feasible and effective surgical option for bilateral groin hernia repair. Patients' outcome was uneventful, with optimal cosmetic results. Further studies comparing this innovative technique to TEP or LESS TEP should be promoted.

  14. Overview of the TREC 2012 Web Track

    DTIC Science & Technology

    2012-11-01

    picture of the Last Supper painting by Leonardo da Vinci . </description> <subtopic number=ŕ" type="nav"> Find a picture of the Last Supper painting by... Leonardo da Vinci . </subtopic> <subtopic number=Ŗ" type="nav"> Are tickets available online to view da Vinci’s Last Supper in Milan, Italy

  15. On the trail of Leonardo

    PubMed Central

    Johnston, P

    1998-01-01

    A night course taken almost 25 years ago sparked an interest in Leonardo da Vinci that has become a passion for a London, Ont., neurosurgeon. Dr. Rolando Del Maestro now boasts one of the largest collections of da Vinci artifacts in North America. PMID:9538858

  16. Can fatigue affect acquisition of new surgical skills? A prospective trial of pre- and post-call general surgery residents using the da Vinci surgical skills simulator.

    PubMed

    Robison, Weston; Patel, Sonya K; Mehta, Akshat; Senkowski, Tristan; Allen, John; Shaw, Eric; Senkowski, Christopher K

    2018-03-01

    To study the effects of fatigue on general surgery residents' performance on the da Vinci Skills Simulator (dVSS). 15 General Surgery residents from various postgraduate training years (PGY2, PGY3, PGY4, and PGY5) performed 5 simulation tasks on the dVSS as recommended by the Robotic Training Network (RTN). The General Surgery residents had no prior experience with the dVSS. Participants were assigned to either the Pre-call group or Post-call group based on call schedule. As a measure of subjective fatigue, residents were given the Epworth Sleepiness Scale (ESS) prior to their dVSS testing. The dVSS MScore™ software recorded various metrics (Objective Structured Assessment of Technical Skills, OSATS) that were used to evaluate the performance of each resident to compare the robotic simulation proficiency between the Pre-call and Post-call groups. Six general surgery residents were stratified into the Pre-call group and nine into the Post-call group. These residents were also stratified into Fatigued (10) or Nonfatigued (5) groups, as determined by their reported ESS scores. A statistically significant difference was found between the Pre-call and Post-call reported sleep hours (p = 0.036). There was no statistically significant difference between the Pre-call and Post-call groups or between the Fatigued and Nonfatigued groups in time to complete exercise, number of attempts, and high MScore™ score. Despite variation in fatigue levels, there was no effect on the acquisition of robotic simulator skills.

  17. Solving Kinetic Equations on GPU’s

    DTIC Science & Technology

    2011-01-01

    7 Acknowledgments 23 8 Appendix: CUDA pseudo-codes 27 ∗Dipartimento di Matematica del Politecnico di Milano Piazza Leonardo da Vinci 32, 20133 Milano...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Dipartimento di Matematica del Politecnico di Milano Piazza Leonardo da Vinci 32, 20133 Milano, Italy 8

  18. Reacting Flows Simulation with Applications to Ground to Flight Extrapolation

    DTIC Science & Technology

    2007-07-01

    P.zza Leonardo da Vinci 32, 20133 Milano, Italy barbante@mate.polimi.it Abstract The development of next generation reusable space vehicles requires a...Politecnico di Milano, Dept. of Mathematics P.zza Leonardo da Vinci 32, 20133 Milano, Italy 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING

  19. Habitat Modeling and Preferences of Marine Mammals as Function of Oceanographic Characteristics: Development of Predictive Tools for Assessing the Risks and the Impacts Due to Sound Emissions

    DTIC Science & Technology

    2011-09-30

    Arianna Azzellino Piazza Leonardo da Vinci , 32, 20133 Milano, Italy phone: (+39) 02-239-964-31 fax: (+39) 02-239-964-99 email...WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Polytechnic University of Milan,Piazza Leonardo da Vinci , 32,20133 Milano, Italy

  20. The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steen-Banasik, Elzbieta M. van der, E-mail: E.vanderSteen-Banasik@radiotherapiegroep.nl; Smits, Geert A.H.J.; Oosterveld, Bernard J.

    Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach withmore » robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.« less

  1. Validation of Robotic Surgery Simulator (RoSS).

    PubMed

    Kesavadas, Thenkurussi; Stegemann, Andrew; Sathyaseelan, Gughan; Chowriappa, Ashirwad; Srimathveeravalli, Govindarajan; Seixas-Mikelus, Stéfanie; Chandrasekhar, Rameella; Wilding, Gregory; Guru, Khurshid

    2011-01-01

    Recent growth of daVinci Robotic Surgical System as a minimally invasive surgery tool has led to a call for better training of future surgeons. In this paper, a new virtual reality simulator, called RoSS is presented. Initial results from two studies - face and content validity, are very encouraging. 90% of the cohort of expert robotic surgeons felt that the simulator was excellent or somewhat close to the touch and feel of the daVinci console. Content validity of the simulator received 90% approval in some cases. These studies demonstrate that RoSS has the potential of becoming an important training tool for the daVinci surgical robot.

  2. Face, content and concurrent validity of the Mimic® dV-Trainer for robot-assisted endoscopic surgery: a prospective study.

    PubMed

    Egi, H; Hattori, M; Tokunaga, M; Suzuki, T; Kawaguchi, K; Sawada, H; Ohdan, H

    2013-01-01

    The aim of this study was to determine whether any correlation exists between the performance of the Mimic® dV-Trainer (Mimic Technologies, Seattle, Wash., USA) and the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, Calif., USA). Twelve participants were recruited, ranging from residents to consultants. We used four training tasks, consisting of 'Pick and Place', 'Peg Board', 'Thread the Rings' and 'Suture Sponge', from the software program of the Mimic dV-Trainer. The performance of the participants was recorded and measured. Additionally, we prepared the same tasks for the da Vinci Surgical System. All participants completed the tasks using the da Vinci Surgical System and were assessed according to time, the Objective Structured Assessment of Technical Skill checklist and the global rating score for endoscopic suturing assessed by two independent blinded observers. After performing these tasks, the participants completed a questionnaire that evaluated the Mimic dV-Trainer's face and content validity. The final results for each participant for the Mimic dV-Trainer and the da Vinci Surgical System were compared. All participants ranked the Mimic dV-Trainer as a realistic training platform that is useful for residency training. There was a significant relationship between the Mimic dV-Trainer and the da Vinci Surgical System in all four tasks. We verified the reliability of the assessment of the checklist and the global rating scores for endoscopic suturing assessed by the two blinded observers using Cronbach's alpha test (r = 0.803, 0.891). We evaluated the concurrent validity of the Mimic dV-Trainer and the da Vinci Surgical System. Our results suggest the possibility that training using the Mimic dV-Trainer may therefore be able to improve the operator's performance during live robot-assisted surgery. © 2013 S. Karger AG, Basel.

  3. Robotic Colorectal Surgery

    PubMed Central

    2008-01-01

    Robotic colorectal surgery has gradually been performed more with the help of the technological advantages of the da Vinci® system. Advanced technological advantages of the da Vinci® system compared with standard laparoscopic colorectal surgery have been reported. These are a stable camera platform, three-dimensional imaging, excellent ergonomics, tremor elimination, ambidextrous capability, motion scaling, and instruments with multiple degrees of freedom. However, despite these technological advantages, most studies did not report the clinical advantages of robotic colorectal surgery compared to standard laparoscopic colorectal surgery. Only one study recently implies the real benefits of robotic rectal cancer surgery. The purpose of this review article is to outline the early concerns of robotic colorectal surgery using the da Vinci® system, to present early clinical outcomes from the most current series, and to discuss not only the safety and the feasibility but also the real benefits of robotic colorectal surgery. Moreover, this article will comment on the possible future clinical advantages and limitations of the da Vinci® system in robotic colorectal surgery. PMID:19108010

  4. 78 FR 58376 - American Asset Development, Inc., aVinci Media Corp., Ceragenix Pharmaceuticals, Inc., Marshall...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] American Asset Development, Inc., aVinci Media..., and Millenium Holding Group, Inc., Order of Suspension of Trading September 19, 2013. It appears to the Securities and Exchange Commission that there is a lack of current and accurate information...

  5. Strategic Insights. Volume 10, Issue 3, Winter 2011

    DTIC Science & Technology

    2011-01-01

    The cover on this edition of Strategic Insights features the NATO sigil overlaid with Leonardo da Vinci’s Vitruvian Man. The original Vitruvian...Man was designed by the Roman architect Vitruvius in an attempt to define artistic proportions for the human body. Da Vinci made adjustments to...Vitruvius’s proportions, making them more accurate. Specifically, da Vinci realized that the circle and square that outline the limits of the man’s limbs

  6. Physical Activity Monitoring: Gadgets and Uses. Article #6 in a 6-Part Series

    ERIC Educational Resources Information Center

    Mears, Derrick

    2010-01-01

    An early 15th century drawing by Leonardo da Vinci depicted a device that used gears and a pendulum that moved in synchronization with the wearer as he or she walked. This is believed to be the early origins of today's physical activity monitoring devices. Today's devices have vastly expanded on da Vinci's ancient concept with a myriad of options…

  7. Is the geological past a key to the (near) future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culotta, E.

    1993-02-12

    Ever since Leonardo da Vinci unearthed beds of fossil marine shells in the Tuscan hills, the record of the past has been challenging conventional theories of climate. Sages of da Vinci's day had a proper explanation for the shells. The clams and snails had drifted into the hills with the waters of the Biblical Flood. But da Vinci didn't think the climatic event chronicled in Genesis could explain the evidence. How, he wondered, could these largely sedentary mollusks have traveled so far in merely 40 days He concluded that the received wisdom was wrong: The marine organisms had lived andmore » died in a vanished sea, just where he found them. But, perhaps fearing papal displeasure, he never published his conclusions.« less

  8. Innovations in Air Insertion (Involving Parachutes)

    DTIC Science & Technology

    2008-03-01

    be utilized to develop lift. ......................52 Figure 18. Leonardo da Vinci and Fausto Veranzio’s canopy designs from the 15th and 16th...The Skydiver’s Handbook, ed. Para Publishing, 6th ed. (Santa Barbara, CA: Para Publishing, 1992), 82. 56 Figure 18. Leonardo da Vinci and Fausto...experimented with rigid, umbrella-like, canopies around 1000 A.D. One of the first recorded canopy designs is Leonardo da Vinci’s late 15th century drawing

  9. Transoral robotic surgery of craniocervical junction and atlantoaxial spine: a cadaveric study.

    PubMed

    Lee, John Y K; O'Malley, Bert W; Newman, Jason G; Weinstein, Gregory S; Lega, Bradley; Diaz, Jason; Grady, M Sean

    2010-01-01

    The goal of this study was to determine the potential role and current limitations of the da Vinci surgical robot in transoral decompression of craniocervical junction (CCJ). The da Vinci Surgical System was used in 2 cadaver heads with neck and clavicles intact. Both neurosurgeons and otolaryngologists familiar with the open microscopic procedure, as well as the transoral robotic surgical procedure, undertook dissection and decompression of the CCJ. The robotic system provided superb illumination and 3D depth perception even several centimeters deep to the posterior oropharyngeal mucosa. The 30 degrees endoscope improved cephalad visualization, eliminating the need to split the soft palate for exposure of the lower clivus. The "intuitive" nature of the da Vinci surgical robot arms provided an advantage in allowing the ability to suture the dura mater in a deep, dark corridor. Because visualization was excellent, tremor-free closure was possible. The authors' findings suggest that transoral robotic surgery, with the da Vinci robot system, holds great potential for decompression of the CCJ as well as resection of both extra- and intradural tumors of this region. Further instrument development is necessary and continued investigation is warranted.

  10. Kinect technology for hand tracking control of surgical robots: technical and surgical skill comparison to current robotic masters.

    PubMed

    Kim, Yonjae; Leonard, Simon; Shademan, Azad; Krieger, Axel; Kim, Peter C W

    2014-06-01

    Current surgical robots are controlled by a mechanical master located away from the patient, tracking surgeon's hands by wire and pulleys or mechanical linkage. Contactless hand tracking for surgical robot control is an attractive alternative, because it can be executed with minimal footprint at the patient's bedside without impairing sterility, while eliminating current disassociation between surgeon and patient. We compared technical and technologic feasibility of contactless hand tracking to the current clinical standard master controllers. A hand-tracking system (Kinect™-based 3Gear), a wire-based mechanical master (Mantis Duo), and a clinical mechanical linkage master (da Vinci) were evaluated for technical parameters with strong clinical relevance: system latency, static noise, robot slave tremor, and controller range. Five experienced surgeons performed a skill comparison study, evaluating the three different master controllers for efficiency and accuracy in peg transfer and pointing tasks. da Vinci had the lowest latency of 89 ms, followed by Mantis with 374 ms and 3Gear with 576 ms. Mantis and da Vinci produced zero static error. 3Gear produced average static error of 0.49 mm. The tremor of the robot used by the 3Gear and Mantis system had a radius of 1.7 mm compared with 0.5 mm for da Vinci. The three master controllers all had similar range. The surgeons took 1.98 times longer to complete the peg transfer task with the 3Gear system compared with Mantis, and 2.72 times longer with Mantis compared with da Vinci (p value 2.1e-9). For the pointer task, surgeons were most accurate with da Vinci with average error of 0.72 mm compared with Mantis's 1.61 mm and 3Gear's 2.41 mm (p value 0.00078). Contactless hand-tracking technology as a surgical master can execute simple surgical tasks. Whereas traditional master controllers outperformed, given that contactless hand-tracking is a first-generation technology, clinical potential is promising and could

  11. Capstone: A Geometry-Centric Platform to Enable Physics-Based Simulation and Design of Systems

    DTIC Science & Technology

    2015-10-05

    foundation for the air-vehicle early design tool DaVinci being developed by CREATETM-AV project to enable development of associative models of air...CREATETM-AV solvers Kestrel [11] and Helios [16,17]. Furthermore, it is the foundation for the CREATETM-AV’s DaVinci [9] tool that provides a... Tools and Environments (CREATETM) program [6] aimed at developing a suite of high- performance physics-based computational tools addressing the needs

  12. Distributed Automated Medical Robotics to Improve Medical Field Operations

    DTIC Science & Technology

    2010-04-01

    ROBOT PATIENT INTERFACE Robotic trauma diagnosis and intervention is performed using instruments and tools mounted on the end of a robotic manipulator...manipulator to respond quickly enough to accommodate for motion due to high inertia and inaccuracies caused by low stiffness at the tool point. Ultrasonic...program was licensed to Intuitive Surgical, Inc and subsequently morphed into the daVinci surgical system. The daVinci has been widely applied in

  13. Psychophysical Studies of Visual Cortical Function

    DTIC Science & Technology

    1992-01-12

    principle of generic image samplin& a hypothesis which provides ageometric tool to understand visual surface learning. We also have investigated the...perception of depth from unpaired points ( DaVinci stereopsis), showing that such points lead to depth andsubjective contours. In color filling in, we have...outlined and systematized a number of important phenomenon which we label under the rubric of DaVinci stereopsis. We summarize these results in a number of

  14. Habitat Modeling and Preferences of Marine Mammals as a Function of Oceanographic Characteristics; Development of Predictive Tools for Assessing the Risks and the Impacts Due to Sound Emissions

    DTIC Science & Technology

    2012-09-30

    Arianna Azzellino Piazza Leonardo da Vinci , 32, 20133 Milano, Italy. phone: (+39) 02-239-964-31 fax: (+39) 02-239-964-99 email...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Piazza Leonardo da Vinci , 32, 20133 Milano, Italy. 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING...ITS A. Magnagni ITS A. Magnagni T-boat Manning CRV Leonardo RV Urania Positve Effort * (km) 2339.39 1700.54 3401.03 504 BW sightings 0

  15. Usefulness of robot-assisted thoracoscopic esophagectomy.

    PubMed

    Osaka, Yoshiaki; Tachibana, Shingo; Ota, Yoshihiro; Suda, Takeshi; Makuuti, Yosuke; Watanabe, Takafumi; Iwasaki, Kenichi; Katsumata, Kenji; Tsuchida, Akihiko

    2018-04-01

    We started robot-assisted thoracoscopic esophagectomy using the da Vinci surgical system from June 2010 and operated on 30 cases by December 2013. Herein, we examined the usefulness of robot-assisted thoracoscopic esophagectomy and compared it with conventional esophagectomy by right thoracotomy. Patients requiring an invasion depth of up to the muscularis propria with preoperative diagnosis were considered for surgical adaptation, excluding bulky lymph node metastasis or salvage surgery cases. The outcomes of 30 patients who underwent robot-assisted surgery (robot group) and 30 patients who underwent conventional esophagectomy by right thoracotomy (thoracotomy group) up to December 2013 were retrospectively examined. Five ports were used in the robot-assisted thoracoscopic esophagectomy: 3rd intercostal (da Vinci right arm), 6th intercostal (da Vinci camera), 9th intercostal (da Vinci left arm), 4th and 8th intercostals (for assistance). There was no significant difference in patient characteristics. Robot group/right thoracotomy group: Operation time, 563/398 min; thoracic procedure bleeding volume, 21/135 ml; number of thoracic lymph node radical dissections, 25/23. Postoperative complications were recurrent nerve paralysis, 16.7/16.7%; pneumonia, 6.7%/10.0%; anastomotic leakage, 10.0/20.0%; surgical site infection, 0/10.0%; hospitalization, 17/30 days. For the robot group, the operation time was significantly longer, but the amount of intraoperative bleeding and postoperative hospitalization were significantly reduced. Robot-assisted thoracoscopic esophagectomy enables delicate surgical procedures owing to the 3D effect of the field of view and articulated forceps of the da Vinci. This procedure reduces bleeding and postoperative hospitalization and is less invasive than conventional esophagectomy by right thoracotomy.

  16. Habitat Modeling of Marine Mammals as Function of Oceanographic Characteristics; Development of Predictive Tools for Assessing and Managing the Risks and the Impacts due to Sound Emissions

    DTIC Science & Technology

    2010-09-30

    Arianna Azzellino Piazza Leonardo da Vinci , 32, 20133 Milano, Italy. phone: (+39) 02-239-964-31 fax: (+39) 02-239-964-99 email...5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Piazza Leonardo da Vinci , 32,20133...Manning CRV Leonardo RV Urania Positve Effort * (km) 2339.39 1700.54 3401.03 504 BW sightings 0 24 2 16 BW cluster of acoustic detections

  17. Robotic hip arthroscopy in human anatomy.

    PubMed

    Kather, Jens; Hagen, Monika E; Morel, Philippe; Fasel, Jean; Markar, Sheraz; Schueler, Michael

    2010-09-01

    Robotic technology offers technical advantages that might offer new solutions for hip arthroscopy. Two hip arthroscopies were performed in human cadavers using the da Vinci surgical system. During both surgeries, a robotic camera and 5 or 8 mm da Vinci trocars with instruments were inserted into the hip joint for manipulation. Introduction of cameras and working instruments, docking of the robotic system and instrument manipulation was successful in both cases. The long articulating area of 5 mm instruments limited movements inside the joint; an 8 mm instrument with a shorter area of articulation offered an improved range of motion. Hip arthroscopy using the da Vinci standard system appears a feasible alternative to standard arthroscopy. Instruments and method of application must be modified and improved before routine clinical application but further research in this area seems justified, considering the clinical value of such an approach. Copyright 2010 John Wiley & Sons, Ltd.

  18. Robotic surgery twice performed in the treatment of hilar cholangiocarcinoma with deep jaundice: delayed right hemihepatectomy following the right-hepatic vascular control.

    PubMed

    Zhu, Zhenyu; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Dong, Maosheng; Mu, Peiyuan; Cheng, Di; Che, Honglei; Zhang, Tao; Xu, Xiaoya; Zhou, Ningxin

    2014-10-01

    To explore and find a new method to treat hilar cholangiocarcinoma with deep jaundice assisted by Da Vinci robot. A hilar cholangiocarcinoma patient of type Bismuch-Corlette IIIa was found with deep jaundice (total bilirubin: 635 µmol/L). On the first admission, we performed Da Vinci robotic surgery including drainage of left hepatic duct, dissection of right hepatic vessels (right portal vein and right hepatic artery), and placement of right-hepatic vascular control device. Three weeks later on the second admission when the jaundice disappeared we occluded right-hepatic vascular discontinuously for 6 days and then sustained later. On the third admission after 3 weeks of right-hepatic vascular control, the right hemihepatectomy was performed by Da Vinci robot for the second time. The future liver remnant after the right-hepatic vascular control increased from 35% to 47%. The volume of left lobe increased by 368 mL. When the total bilirubin and liver function were all normal, right hemihepatectomy was performed by Da Vinci robot 10 weeks after the first operation. The removal of atrophic right hepatic lobe with tumor in bile duct was found with no pathologic cancer remaining in the margin. The patient was followed up at our outpatient clinic every 3 months and no tumor recurrence occurs by now (1 y). Under the Da Vinci robotic surgical system, a programmed treatment can be achieved: first, the hepatic vessels were controlled gradually together with biliary drainage, which results in liver's partial atrophy and compensatory hypertrophy in the other part. Then a radical hepatectomy could be achieved. Such programmed hepatectomy provides a new treatment for patients of hilar cholangiocarcinoma with deep jaundice who have the possibility of radical heptolobectomy.

  19. Proficiency training on a virtual reality robotic surgical skills curriculum.

    PubMed

    Bric, Justin; Connolly, Michael; Kastenmeier, Andrew; Goldblatt, Matthew; Gould, Jon C

    2014-12-01

    The clinical application of robotic surgery is increasing. The skills necessary to perform robotic surgery are unique from those required in open and laparoscopic surgery. A validated laparoscopic surgical skills curriculum (Fundamentals of Laparoscopic Surgery or FLS™) has transformed the way surgeons acquire laparoscopic skills. There is a need for a similar skills training and assessment tool for robotic surgery. Our research group previously developed and validated a robotic training curriculum in a virtual reality (VR) simulator. We hypothesized that novice robotic surgeons could achieve proficiency levels defined by more experienced robotic surgeons on the VR robotic curriculum, and that this would result in improved performance on the actual daVinci Surgical System™. 25 medical students with no prior robotic surgery experience were recruited. Prior to VR training, subjects performed 2 FLS tasks 3 times each (Peg Transfer, Intracorporeal Knot Tying) using the daVinci Surgical System™ docked to a video trainer box. Task performance for the FLS tasks was scored objectively. Subjects then practiced on the VR simulator (daVinci Skills Simulator) until proficiency levels on all 5 tasks were achieved before completing a post-training assessment of the 2 FLS tasks on the daVinci Surgical System™ in the video trainer box. All subjects to complete the study (1 dropped out) reached proficiency levels on all VR tasks in an average of 71 (± 21.7) attempts, accumulating 164.3 (± 55.7) minutes of console training time. There was a significant improvement in performance on the robotic FLS tasks following completion of the VR training curriculum. Novice robotic surgeons are able to attain proficiency levels on a VR simulator. This leads to improved performance in the daVinci surgical platform on simulated tasks. Training to proficiency on a VR robotic surgery simulator is an efficient and viable method for acquiring robotic surgical skills.

  20. Sensorization of a surgical robotic instrument for force sensing

    NASA Astrophysics Data System (ADS)

    Shahzada, Kaspar S.; Yurkewich, Aaron; Xu, Ran; Patel, Rajni V.

    2016-03-01

    This paper presents the development and application of an approach for sensorizing a surgical robotic instrument for two degree-of-freedom (DOF) lateral force sensing. The sensorized instrument is compatible with the da Vinci® Surgical System and can be used for skills assessment and force control in specific surgical tasks. The sensing technology utilizes a novel layout of four fiber Bragg grating (FBG) sensors attached to the shaft of a da Vinci® surgical instrument. The two cross-section layout is insensitive to error caused by combined force and torque loads, and the orientation of the sensors minimizes the condition number of the instrument's compliance matrix. To evaluate the instrument's sensing capabilities, its performance was tested using a commercially available force-torque sensor, and showed a resolution of 0.05N at 1 kHz sampling rate. The performance of the sensorized instrument was evaluated by performing three surgical tasks on phantom tissue using the da Vinci® system with the da Vinci Research Kit (dVRK): tissue palpation, knot tightening during suturing and Hem-O-Lok® tightening during knotless suturing. The tasks were designed to demonstrate the robustness of the sensorized force measurement approach. The paper reports the results of further evaluation by a group of expert and novice surgeons performing the three tasks mentioned above.

  1. [The advancement of robotic surgery--successes, failures, challenges].

    PubMed

    Haidegger, Tamás

    2010-10-10

    Computer-integrated robotic surgery systems appeared more than twenty years ago and since then hundreds of different prototypes have been developed. Only a fraction of them have been commercialized, mostly to support neurosurgical and orthopaedic procedures.Unquestionably, the most successful one is the da Vinci surgical system, primarily deployed in urology and general laparoscopic surgery. It is developed and marketed by Intuitive Surgical Inc. (Sunnyvale, CA, USA), the only profitable company of the segment. The da Vinci made robotic surgery is known and acknowledged throughout the world, and the great results delivered convinced most of the former critics of the technology. Success derived from the well chosen business development strategy, proficiency of the developers, appropriate timing and a huge pot of luck. This article presents the most important features of the da Vinci system, the history of development along with its medical, economical and financial aspects, and seeks the answer why this particular system became successful.

  2. Single-port robotic cholecystectomy. Initial and pioneer experience in Brazil

    PubMed Central

    Schraibman, Vladimir; Epstein, Marina Gabrielle; Maccapani, Gabriel Naman; Macedo, Antônio Luiz de Vasconcellos

    2015-01-01

    The technique of a single-port laparoscopy was developed over the last years as an attempt to lower surgical aggression and improve the aesthetic results of the minimally invasive surgery. A new robotic platform used with the da Vinci® Robotic System Single-Site System® (Intuitive Surgical, Sunnyvale, California, United States) was recently launched on the global market and is still not documented in Brazil. The authors report on the first four robotic single-port cholecystectomies performed with this da Vinci® Robotic System in Brazil. PMID:26398360

  3. A second Leonardo da Vinci?

    PubMed

    Nakano, Mitsuko; Endo, Toshitaka; Tanaka, Shigeki

    2003-10-01

    We describe a young woman who suddenly began mirror writing with her right hand and has not reverted to normal writing for more than 6 years, although she writes normally with her left hand. She is ambidextrous, although she had previously used only her right hand for writing and drawing. Since it is much easier for her to use right-handed mirror writing, she uses her left hand only for writing meant to be read by others and her right hand for all other writing. Her hobbies are sculpture and painting, and her chief complaint is migraine accompanied by sensory and perceptive disturbances.

  4. Current state of virtual reality simulation in robotic surgery training: a review.

    PubMed

    Bric, Justin D; Lumbard, Derek C; Frelich, Matthew J; Gould, Jon C

    2016-06-01

    Worldwide, the annual number of robotic surgical procedures continues to increase. Robotic surgical skills are unique from those used in either open or laparoscopic surgery. The acquisition of a basic robotic surgical skill set may be best accomplished in the simulation laboratory. We sought to review the current literature pertaining to the use of virtual reality (VR) simulation in the acquisition of robotic surgical skills on the da Vinci Surgical System. A PubMed search was conducted between December 2014 and January 2015 utilizing the following keywords: virtual reality, robotic surgery, da Vinci, da Vinci skills simulator, SimSurgery Educational Platform, Mimic dV-Trainer, and Robotic Surgery Simulator. Articles were included if they were published between 2007 and 2015, utilized VR simulation for the da Vinci Surgical System, and utilized a commercially available VR platform. The initial search criteria returned 227 published articles. After all inclusion and exclusion criteria were applied, a total of 47 peer-reviewed manuscripts were included in the final review. There are many benefits to utilizing VR simulation for robotic skills acquisition. Four commercially available simulators have been demonstrated to be capable of assessing robotic skill. Three of the four simulators demonstrate the ability of a VR training curriculum to improve basic robotic skills, with proficiency-based training being the most effective training style. The skills obtained on a VR training curriculum are comparable with those obtained on dry laboratory simulation. The future of VR simulation includes utilization in assessment for re-credentialing purposes, advanced procedural-based training, and as a warm-up tool prior to surgery.

  5. Robotic technology in surgery: current status in 2008.

    PubMed

    Murphy, Declan G; Hall, Rohan; Tong, Raymond; Goel, Rajiv; Costello, Anthony J

    2008-12-01

    There is increasing patient and surgeon interest in robotic-assisted surgery, particularly with the proliferation of da Vinci surgical systems (Intuitive Surgical, Sunnyvale, CA, USA) throughout the world. There is much debate over the usefulness and cost-effectiveness of these systems. The currently available robotic surgical technology is described. Published data relating to the da Vinci system are reviewed and the current status of surgical robotics within Australia and New Zealand is assessed. The first da Vinci system in Australia and New Zealand was installed in 2003. Four systems had been installed by 2006 and seven systems are currently in use. Most of these are based in private hospitals. Technical advantages of this system include 3-D vision, enhanced dexterity and improved ergonomics when compared with standard laparoscopic surgery. Most procedures currently carried out are urological, with cardiac, gynaecological and general surgeons also using this system. The number of patients undergoing robotic-assisted surgery in Australia and New Zealand has increased fivefold in the past 4 years. The most common procedure carried out is robotic-assisted laparoscopic radical prostatectomy. Published data suggest that robotic-assisted surgery is feasible and safe although the installation and recurring costs remain high. There is increasing acceptance of robotic-assisted surgery, especially for urological procedures. The da Vinci surgical system is becoming more widely available in Australia and New Zealand. Other surgical specialties will probably use this technology. Significant costs are associated with robotic technology and it is not yet widely available to public patients.

  6. Moving Along: In biomechanics, rehabilitation engineering, and movement analysis, Italian researchers are making great strides.

    PubMed

    Gugliellmelli, Eugenio; Micera, Silvestro; Migliavacca, Francesco; Pedotti, Antonio

    2015-01-01

    In Italy, biomechanics research and the analysis of human and animal movement have had a very long history, beginning with the exceptional pioneering work of Leonardo da Vinci. In 1489, da Vinci began investigating human anatomy, including an examination of human tendons, muscles, and the skeletal system. He continued this line of inquiry later in life, identifying what he called "the four powers--movement, weight, force, and percussion"--and how he thought they worked in the human body. His approach, by the way, was very modern--analyzing nature through anatomy, developing models for interpretation, and transferring this knowledge to bio-inspired machines.

  7. [Robotic laparoscopic cholecystectomy].

    PubMed

    Langer, D; Pudil, J; Ryska, M

    2006-09-01

    Laparoscopic approach profusely utilized in many surgical fields was enhanced by da Vinci robotic surgical system in range of surgery wards, imprimis in the United States today. There was multispecialized robotic centre program initiated in the Central Military Hospital in Prague in December 2005. Within the scope of implementing the da Vinci robotic system to clinical practice we executed robotic-assisted laparoscopic cholecystectomy. We have accomplished elective laparoscopic cholecystectomy using the da Vinci robotic surgical system. Operating working group (two doctors, two scrub nurses) had completed certificated foreign training. Both of the surgeons have many years experience of laparoscopic cholecystectomy. Operator controlled instruments from the surgeon's console, assistant placed clips on ends of cystic duct and cystic artery from auxiliary port after capnoperitoneum installation. We evacuated gallbladder in plastic bag from abdominal cavity in place of original paraumbilical port. We were exploiting three working arms in all our cases, holding surgical camera, electrocautery hook and Cadiere forceps. We had been observing procedure time, technical complications connected with robotic system, length of hospital stay and complication incidence rate. We managed to finish all operations in laparoscopic way. Group of our patients formed 11 male patients (35.5%) and 20 women (64.5%), mean aged 52.5 years in range of 27 77 years. The average operation procedure lasted 100 minutes, in the group of last 11 patients only 69 minutes. We recorded paraumbilical wound infections in 3 (9.7 %) patients. We had not experienced any technical problems with robotic surgical system. Length of hospital stay was 3 days. Considering our initial experience with robotic lasparoscopic cholecystectomy we evaluate da Vinci robotic surgical system to be safe and sophisticated operating manipulator which however does not substitute the surgeon key-role of controlling position and

  8. Quantum Turbulence ---Another da Vinci Code---

    NASA Astrophysics Data System (ADS)

    Tsubota, M.

    Quantum turbulence comprises a tangle of quantized vorticeswhich are stable topological defects created by Bose-Einstein condensation, being realized in superfluid helium and atomic Bose-Einstein condensates. In recent years there has been a growing interest in quantum turbulence. One of the important motivations is to understand the relation between quantum and classical turbulence. Quantum turbulence is expected to be much simpler than usual classical turbulence and give a prototype of turbulence. This article reviews shortly the recent research developments on quantum turbulence.

  9. Augmented reality to the rescue of the minimally invasive surgeon. The usefulness of the interposition of stereoscopic images in the Da Vinci™ robotic console.

    PubMed

    Volonté, Francesco; Buchs, Nicolas C; Pugin, François; Spaltenstein, Joël; Schiltz, Boris; Jung, Minoa; Hagen, Monika; Ratib, Osman; Morel, Philippe

    2013-09-01

    Computerized management of medical information and 3D imaging has become the norm in everyday medical practice. Surgeons exploit these emerging technologies and bring information previously confined to the radiology rooms into the operating theatre. The paper reports the authors' experience with integrated stereoscopic 3D-rendered images in the da Vinci surgeon console. Volume-rendered images were obtained from a standard computed tomography dataset using the OsiriX DICOM workstation. A custom OsiriX plugin was created that permitted the 3D-rendered images to be displayed in the da Vinci surgeon console and to appear stereoscopic. These rendered images were displayed in the robotic console using the TilePro multi-input display. The upper part of the screen shows the real endoscopic surgical field and the bottom shows the stereoscopic 3D-rendered images. These are controlled by a 3D joystick installed on the console, and are updated in real time. Five patients underwent a robotic augmented reality-enhanced procedure. The surgeon was able to switch between the classical endoscopic view and a combined virtual view during the procedure. Subjectively, the addition of the rendered images was considered to be an undeniable help during the dissection phase. With the rapid evolution of robotics, computer-aided surgery is receiving increasing interest. This paper details the authors' experience with 3D-rendered images projected inside the surgical console. The use of this intra-operative mixed reality technology is considered very useful by the surgeon. It has been shown that the usefulness of this technique is a step toward computer-aided surgery that will progress very quickly over the next few years. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Technological advances in robotic-assisted laparoscopic surgery.

    PubMed

    Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K

    2009-05-01

    In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.

  11. iss037-s-001

    NASA Image and Video Library

    2012-07-27

    ISS037-S-001 (August 2012) --- Leonardo da Vinci's Vitruvian Man, created some 525 years ago, as a blend of art and science and a symbol of the medical profession, is depicted amongst the orbits of a variety of satellites circling the Earth at great speed. Da Vinci's drawing, based on the proportions of man as described by the Roman architect Vitruvius, is often used as a symbol of symmetry of the human body and the universe as a whole. Almost perfect in symmetry as well, the International Space Station, with its solar wings spread out and illuminated by the first rays of dawn, is pictured as a mighty beacon arcing upwards across our night skies, the ultimate symbol of science and technology of our age. Six stars represent the six members of Expedition 37 crew, which includes two cosmonauts with a medical background, as well as a native of Da Vinci's Italy. The design for insignia for space station flights is reserved for use by the crew members and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the form of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, it will be publicly announced.

  12. Robotic Head and Neck Surgery: History, Technical Evolution and the Future.

    PubMed

    Garas, George; Arora, Asit

    2018-06-20

    The first application of robotic technology in surgery was described in 1985 when a robot was used to define the trajectory for a stereotactic brain biopsy. Following its successful application in a variety of surgical operations, the da Vinci® robot, the most widely used surgical robot at present, made its clinical debut in otorhinolaryngology and head and neck surgery in 2005 when the first transoral robotic surgery (TORS) resections of base of tongue neoplasms were reported. Subsequently, the indications for TORS rapidly expanded, and they now include tumours of the oropharynx, hypopharynx, parapharyngeal space, and supraglottic larynx, as well as obstructive sleep apnoea (OSA). The da Vinci® robot has also been successfully used for scarless-in-the-neck thyroidectomy and parathyroidectomy. At present, the main barrier to the wider uptake of robotic surgery is the prohibitive cost of the da Vinci® robotic system. Several novel, flexible surgical robots are currently being developed that are likely to not only enhance patient safety and expand current indications but also drive down costs, thus making this innovation more widely available. Future directions relate to overlay technology through augmented reality/AR that allows real-time image-guidance, miniaturisation (nanorobots), and the development of autonomous robots. © 2018 S. Karger AG, Basel.

  13. Inland Resupply Without a Road or Runway: Airdrop Solutions Including High-Altitude Precision Systems

    DTIC Science & Technology

    2008-03-01

    consider the origin of the parachute they probably envision the pyramidal drawing of Leonardo da Vinci from the late 1400s. However, the Chinese are...refining their designs. Like da Vinci’s plan, most had a rigid frame limiting their versatility. The practical use for the parachute was

  14. Interferometric observations of η Carinae with VINCI/VLTI

    NASA Astrophysics Data System (ADS)

    Kervella, P.

    2007-03-01

    Context: The bright star η Carinae is the most massive and luminous star in our region of the Milky Way. Though it has been extensively studied using many different techniques, its physical nature and the mechanism that led to the creation of the Homunculus nebula are still debated. Aims: We aimed at resolving the central engine of the η Carinae complex in the near-infrared on angular scales of a few milliarcseconds. Methods: We used the VINCI instrument of the VLTI to recombine coherently the light from two telescopes in the K band. Results: We report a total of 142 visibility measurements of η Car, part of which were analyzed by Van Boekel et al. (2003, A&A, 410, L37). These observations were carried out on projected baselines ranging from 8 to 112 m in length, using either two 0.35 m siderostats or two 8-m Unit Telescopes. These observations cover the November 2001-January 2004 period. Conclusions: .The reported visibility data are in satisfactory agreement with the recent results obtained with AMBER/VLTI by Weigelt et al. (2006), asuming that the flux of η Car encircled within 70 mas reaches 56% of the total flux within 1400 mas, in the K band. We also confirm that the squared visibility curve of η Car as a function of spatial frequency follows closely an exponential model. Table 1 is only available in electronic form at http://www.aanda.org

  15. Robotic surgery: new robots and finally some real competition!

    PubMed

    Rao, Pradeep P

    2018-04-01

    For the last 20 years, the predominant robot used in laparoscopic surgery has been Da Vinci by Intuitive Surgical. This monopoly situation has led to rising costs and relatively slow innovation. This article aims to discuss the two new robotic devices for laparoscopic surgery which have received regulatory approval for human use in different parts of the world. A short description of the Senhance Surgical Robotic System and the REVO-I Robot Platform and their pros and cons compared to the Da Vinci system is presented. A discussion about the differences between the three robotic systems now in the market is presented, as well as a short review of the present state of robotic assistance in surgery and where we are headed.

  16. Leonardo's Tree Theory.

    ERIC Educational Resources Information Center

    Werner, Suzanne K.

    2003-01-01

    Describes a series of activities exploring Leonardo da Vinci's tree theory that are designed to strengthen 8th grade students' data collection and problem solving skills in physical science classes. (KHR)

  17. [Sacrocolpopexy - pro laparoscopic].

    PubMed

    Hatzinger, M; Sohn, M

    2012-05-01

    Innovative techniques have a really magical attraction for physicians as well as for patients. The number of robotic-assisted procedures worldwide has almost tripled from 80,000 procedures in the year 2007 to 205,000 procedures in 2010. In the same time the total number of Da Vinci surgery systems sold climbed from 800 to 1,400. Advantages, such as three-dimensional visualization, a tremor-filter, an excellent instrument handling with 6 degrees of freedom and better ergonomics, together with aggressive marketing led to a veritable flood of new Da Vinci acquisitions in the whole world. Many just took the opportunity to introduce a new instrument to save a long learning curve and start immediately in the surgical master class.If Da Vinci sacrocolpopexy is compared with the conventional laparoscopic approach, robotic-assisted sacrocolpopexy shows a significantly longer duration of the procedure, a higher need for postoperative analgesics, much higher costs and an identical functional outcome without any advantage over the conventional laparoscopic approach. Although the use of robotic-assisted systems shows a significantly lower learning curve for laparoscopic beginners, it only shows minimal advantages for the experienced laparoscopic surgeon. Therefore it remains uncertain whether robotic-assisted surgery shows a significant advantage compared to the conventional laparoscopic surgery, especially with small reconstructive laparoscopic procedures such as sacrocolpopexy.

  18. Robot-Assisted Transoral Odontoidectomy : Experiment in New Minimally Invasive Technology, a Cadaveric Study

    PubMed Central

    Yang, Moon Sul; Yoon, Tae Ho; Yoon, Do Heum; Kim, Keung Nyun; Pennant, William

    2011-01-01

    Objective In the field of spinal surgery, a few laboratory results or clinical cases about robotic spinal surgery have been reported. In vivo trials and development of related surgical instruments for spinal surgery are required before its clinical application. We investigated the use of the da Vinci® Surgical System in spinal surgery at the craniovertebral junction in a human cadaver to demonstrate the efficacy and pitfalls of robotic surgery. Methods Dissection of pharyngeal wall to the exposure of C1 and odontoid process was performed with full robotic procedure. Although assistance of another surgeon was necessary for drilling and removal of odontoid process due to the lack of appropriate end-effectors, successful robotic procedures for dural sutures and exposing spinal cord proved its safety and dexterity. Results Robot-assisted odontoidectomy was successfully performed in a human cadaver using the da Vinci® Surgical System with few robotic arm collisions and minimal soft tissue damages. Da Vinci® Surgical System manifested more dexterous movement than human hands in the deep and narrow oral cavity. Furthermore, sutures with robotic procedure in the oral cavity demonstrated the advantage over conventional procedure. Conclusion Presenting cadaveric study proved the probability of robot-assisted transoral approach. However, the development of robotic instruments specific to spinal surgery must first precede its clinical application. PMID:21607188

  19. Robotics applied in laparoscopic kidney surgery: the Yonsei University experience of 127 cases.

    PubMed

    Lorenzo, Enrique Ian S; Jeong, Wooju; Oh, Cheol Kyu; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho

    2011-01-01

    We report our experience on 127 kidney surgeries with the da Vinci surgical system and show the feasibility of a robotics application in a variety of kidney surgeries by both a laparoscopically-trained and a laparoscopically-naïve surgeon. Clinical data of patients who underwent kidney surgery with the da Vinci surgical system from September 2006 to April 2009 were reviewed. Data acquired from medical records included patient demographics, operative time, estimated blood loss (EBL), incidence of intraoperative complication, duration of hospital stay, blood transfusion rate, oncological outcomes, and follow-up results. One-hundred twenty-seven kidney surgeries have been conducted with the da Vinci surgical system at our institution. Three urologists--1 with formal endourology training, 1 with laparoscopic experience, and 1 laparoscopically naïve--have used it for a variety of procedures involving the kidney. The cases include 65 partial nephrectomies (RPN), 38 radical nephrectomies (RRN), and 24 nephroureterectomies with bladder cuff (RNU). Results on operative time, EBL, incidence of intraoperative injury, duration of hospital stay, and blood transfusion rate are comparable with contemporary studies. Robotics application in kidney surgery is a viable option for various procedures. Our experience shows it can be safely and effectively conducted by both laparoscopically-trained and laparoscopically-naïve surgeons once they are accustomed to the robotics system. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Robot-assisted single-site compared with laparoscopic single-incision cholecystectomy for benign gallbladder disease: protocol for a randomized controlled trial.

    PubMed

    Grochola, Lukasz Filip; Soll, Christopher; Zehnder, Adrian; Wyss, Roland; Herzog, Pascal; Breitenstein, Stefan

    2017-02-09

    Recent advances in robotic technology suggest that the utilization of the da Vinci Single-Site™ platform for cholecystectomy is safe, feasible and results in a shorter learning curve compared to conventional single-incision laparoscopic cholecystectomy. Moreover, the robot-assisted technology has been shown to reduce the surgeon's stress load compared to standard single-incision laparoscopy in an experimental setup, suggesting an important advantage of the da Vinci platform. However, the above-mentioned observations are based solely on case series, case reports and experimental data, as high-quality clinical trials to demonstrate the benefits of the da Vinci Single-Site™ cholecystectomy have not been performed to date. This study addresses the question whether robot-assisted Single-Site™ cholecystectomy provides significant benefits over single-incision laparoscopic cholecystectomy in terms of surgeon's stress load, while matching the standards of the conventional single-incision approach with regard to peri- and postoperative outcomes. It is designed as a single centre, single-blinded randomized controlled trial, which compares both surgical approaches with the primary endpoint surgeon's physical and mental stress load at the time of surgery. In addition, the study aims to assess secondary endpoints such as operating time, conversion rates, additional trocar placement, intra-operative blood loss, length of hospital stay, costs of procedure, health-related quality of life, cosmesis and complications. Patients as well as ward staff are blinded until the 1 st postoperative year. Sample size calculation based on the results of a previously published experimental setup utilizing an estimated effect size of surgeon's comfort of 0.8 (power of 0.8, alpha-error level of 0.05, error margin of 10-15%) resulted in a number of 30 randomized patients per arm. The study is the first randomized controlled trial that compares the da Vinci Single Site™ platform to

  1. Tourism. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This brochure, part of a series about good practices in vocational training in the European Union, describes 10 projects that have promoted investment in human resources through training in the tourism sector to promote sustainable, or responsible, tourism. The projects and their countries of origin are as follows: (1) BEEFT, training of mobility…

  2. [Studies of vision by Leonardo da Vinci].

    PubMed

    Berggren, L

    2001-01-01

    Leonardo was an advocate of the intromission theory of vision. Light rays from the object to the eye caused visual perceptions which were transported to the brain ventricles via a hollow optic nerve. Leonardo introduced wax injections to explore the ventricular system. Perceptions were assumed to go to the "senso comune" in the middle (3rd) ventricle, also the seat of the soul. The processing station "imprensiva" in the anterior lateral horns together with memory "memoria" in th posterior (4th) ventricle integrated the visual perceptions to visual experience. - Leonardo's sketches with circular lenses in the center of the eye reveal that his dependence on medieval optics prevailed over anatomical observations. Drawings of the anatomy of the sectioned eye are missing although Leonardo had invented a new embedding technique. In order to dissect the eye without spilling its contents, the eye was first boiled in egg white and then cut. The procedure was now repeated and showed that the ovoid lens after boiling had become spherical. - Leonardo described that light rays were refracted and reflected in the eye but his imperfect anatomy prevented a development of physiological optics. He was, however, the first to compare the eye with a pin-hole camera (camera obscura). Leonardo's drawings of the inverted pictures on the back wall of a camera obscura inspired to its use as an instrument for artistic practice. The camera obscura was for centuries a model for explaining human vision.

  3. A prospective comparison of robotic and laparoscopic pyeloplasty.

    PubMed

    Link, Richard E; Bhayani, Sam B; Kavoussi, Louis R

    2006-04-01

    To determine whether robotic-assisted pyeloplasty (RLP) has any significant clinical or cost advantages over laparoscopic pyeloplasty (LP) for surgeons already facile with intracorporeal suturing. LP has become an established management approach for primary ureteropelvic junction obstruction. More recently, the da Vinci robot has been applied to this procedure (RLP) in an attempt to shorten the learning curve. Whether RLP provides any significant advantage over LP for the experienced laparoscopist remains unclear. Ten consecutive cases each of transperitoneal RLP and LP performed by a single surgeon were compared prospectively with respect to surgical times and perioperative outcomes. Cost assessment was performed by sensitivity analysis using a mathematical cost model incorporating operative time, anesthesia fees, consumables, and capital equipment depreciation. The RLP and LP groups had statistically indistinguishable demographics, pathology, and similar perioperative outcomes. Mean operative and total room time for RLP was significantly longer than LP by 19.5 and 39.0 minutes, respectively. RLP was much more costly than LP (2.7 times), due to longer operative time, increased consumables costs, and depreciation of the costly da Vinci system. However, even if depreciation was eliminated, RLP was still 1.7 times as costly as LP. One-way sensitivity analysis showed that LP operative time must increase to almost 6.5 hours for it to become cost equivalent to RLP. For the experienced laparoscopist, application of the da Vinci robot resulted in no significant clinical advantage and added substantial cost to transperitoneal laparoscopic dismembered pyeloplasty.

  4. Kate Steinitz, Librarian, Artist, Scholar; Being a Thirteen-Part Tribute to One Whose Verve Has Enlivened Some Eight Decades on Two Continents

    ERIC Educational Resources Information Center

    Wilson Libr Bull, 1970

    1970-01-01

    Personal reminiscences about the Dada artist, expert on Leonardo da Vinci, and librarian at the UCLA Library of Vinciana by museum directors, scholars, and friends. Includes selected bibliography of her works, a chronology, poems, sketches, and photographs. (JS)

  5. System design and animal experiment study of a novel minimally invasive surgical robot.

    PubMed

    Wang, Wei; Li, Jianmin; Wang, Shuxin; Su, He; Jiang, Xueming

    2016-03-01

    Robot-assisted minimally invasive surgery has shown tremendous advances over the traditional technique. However, currently commercialized systems are large and complicated, which vastly raises the system cost and operation room requirements. A MIS robot named 'MicroHand' was developed over the past few years. The basic principle and the key technologies are analyzed in this paper. Comparison between the proposed robot and the da Vinci system is also presented. Finally, animal experiments were carried out to test the performance of MicroHand. Fifteen animal experiments were carried out from July 2013 to December 2013. All animal experiments were finished successfully. The proposed design method is an effective way to resolve the drawbacks of previous generations of the da Vinci surgical system. The animal experiment results confirmed the feasibility of the design. Copyright © 2015 John Wiley & Sons, Ltd.

  6. From Illusion to Reality: A Brief History of Robotic Surgery.

    PubMed

    Marino, Marco Vito; Shabat, Galyna; Gulotta, Gaspare; Komorowski, Andrzej Lech

    2018-06-01

    Robotic surgery is currently employed for many surgical procedures, yielding interesting results. We performed an historical review of robots and robotic surgery evaluating some critical phases of its evolution, analyzing its impact on our life and the steps completed that gave the robotics its current popularity. The origins of robotics can be traced back to Greek mythology. Different aspects of robotics have been explored by some of the greatest inventors like Leonardo da Vinci, Pierre Jaquet-Droz, and Wolfgang Von-Kempelen. Advances in many fields of science made possible the development of advanced surgical robots. Over 3000 da Vinci robotic platforms are installed worldwide, and more than 200 000 robotic procedures are performed every year. Despite some potential adverse events, robotic technology seems safe and feasible. It is strictly linked to our life, leading surgeons to a new concept of surgery and training.

  7. Physics Based Modeling in Design and Development for U.S. Defense Held in Denver, Colorado on November 14-17, 2011. Volume 2: Audio and Movie Files

    DTIC Science & Technology

    2011-11-17

    Mr. Frank Salvatore, High Performance Technologies FIXED AND ROTARY WING AIRCRAFT 13274 - “CREATE-AV DaVinci : Model-Based Engineering for Systems... Tools for Reliability Improvement and Addressing Modularity Issues in Evaluation and Physical Testing”, Dr. Richard Heine, Army Materiel Systems

  8. Postmodern Irony as Subversive Rhetorical Strategy.

    ERIC Educational Resources Information Center

    Shugart, Helene A.

    1999-01-01

    Contributes to scholarship advancing the understanding of human communication by analyzing Susan Dorothea White's painting, "The First Supper," as a subversive postmodern ironic reading of Leonardo Da Vinci's "The Last Supper." Suggests that subversive irony assumes distinctive and complex technical and theoretical…

  9. The Dangers of Art "Appreciation."

    ERIC Educational Resources Information Center

    Irvine, Hope

    1991-01-01

    Addresses the issue of the fame of Leonardo da Vinci's "Mona Lisa." Describes several kitsch objects that have been created about the painting. Maintains that students need to address this issue otherwise such exploitation will depreciate the value of the art work. (KM)

  10. Teaching Science: A Picture Perfect Process.

    ERIC Educational Resources Information Center

    Leyden, Michael B.

    1994-01-01

    Explains how teachers can use graphs and graphing concepts when teaching art, language arts, history, social studies, and science. Students can graph the lifespans of the Ninja Turtles' Renaissance namesakes (Donatello, Michelangelo, Raphael, and Leonardo da Vinci) or world population growth. (MDM)

  11. [Distance learning using internet in the field of bioengineering].

    PubMed

    Ciobanu, O

    2003-01-01

    The Leonardo da Vinci training programme supports innovative transnational initiatives for promoting the knowledge, aptitudes and skills necessary for successful integration into working life. Biomedical engineering is an emerging interdisciplinary field that contributes to understand, define and solve problems in biomedical technology within industrial and health service contexts. Paper presents a Leonardo da Vinci pilot-project called Web-based learning and training in the field of biomedical and design engineering (WEBD). This project has started on 2001. The WEBD project proposes to use advanced learning technologies to provide education in the www. Project uses interactive 3D graphics and virtual reality tools. The WEBD distance training permits users to experience and interact with a life-like model or environment, in safety and at convenient times, while providing a degree of control over the simulation that is usually not possible in the real-life situation.

  12. A Prospective Comparison of Robotic and Laparoscopic Pyeloplasty

    PubMed Central

    Link, Richard E.; Bhayani, Sam B.; Kavoussi, Louis R.

    2006-01-01

    Objective: To determine whether robotic-assisted pyeloplasty (RLP) has any significant clinical or cost advantages over laparoscopic pyeloplasty (LP) for surgeons already facile with intracorporeal suturing. Summary Background Data: LP has become an established management approach for primary ureteropelvic junction obstruction. More recently, the da Vinci robot has been applied to this procedure (RLP) in an attempt to shorten the learning curve. Whether RLP provides any significant advantage over LP for the experienced laparoscopist remains unclear. Methods: Ten consecutive cases each of transperitoneal RLP and LP performed by a single surgeon were compared prospectively with respect to surgical times and perioperative outcomes. Cost assessment was performed by sensitivity analysis using a mathematical cost model incorporating operative time, anesthesia fees, consumables, and capital equipment depreciation. Results: The RLP and LP groups had statistically indistinguishable demographics, pathology, and similar perioperative outcomes. Mean operative and total room time for RLP was significantly longer than LP by 19.5 and 39.0 minutes, respectively. RLP was much more costly than LP (2.7 times), due to longer operative time, increased consumables costs, and depreciation of the costly da Vinci system. However, even if depreciation was eliminated, RLP was still 1.7 times as costly as LP. One-way sensitivity analysis showed that LP operative time must increase to almost 6.5 hours for it to become cost equivalent to RLP. Conclusions: For the experienced laparoscopist, application of the da Vinci robot resulted in no significant clinical advantage and added substantial cost to transperitoneal laparoscopic dismembered pyeloplasty. PMID:16552199

  13. System for robot-assisted real-time laparoscopic ultrasound elastography

    NASA Astrophysics Data System (ADS)

    Billings, Seth; Deshmukh, Nishikant; Kang, Hyun Jae; Taylor, Russell; Boctor, Emad M.

    2012-02-01

    Surgical robots provide many advantages for surgery, including minimal invasiveness, precise motion, high dexterity, and crisp stereovision. One limitation of current robotic procedures, compared to open surgery, is the loss of haptic information for such purposes as palpation, which can be very important in minimally invasive tumor resection. Numerous studies have reported the use of real-time ultrasound elastography, in conjunction with conventional B-mode ultrasound, to differentiate malignant from benign lesions. Several groups (including our own) have reported integration of ultrasound with the da Vinci robot, and ultrasound elastography is a very promising image guidance method for robotassisted procedures that will further enable the role of robots in interventions where precise knowledge of sub-surface anatomical features is crucial. We present a novel robot-assisted real-time ultrasound elastography system for minimally invasive robot-assisted interventions. Our system combines a da Vinci surgical robot with a non-clinical experimental software interface, a robotically articulated laparoscopic ultrasound probe, and our GPU-based elastography system. Elasticity and B-mode ultrasound images are displayed as picture-in-picture overlays in the da Vinci console. Our system minimizes dependence on human performance factors by incorporating computer-assisted motion control that automatically generates the tissue palpation required for elastography imaging, while leaving high-level control in the hands of the user. In addition to ensuring consistent strain imaging, the elastography assistance mode avoids the cognitive burden of tedious manual palpation. Preliminary tests of the system with an elasticity phantom demonstrate the ability to differentiate simulated lesions of varied stiffness and to clearly delineate lesion boundaries.

  14. A pilot study of surgical training using a virtual robotic surgery simulator.

    PubMed

    Tergas, Ana I; Sheth, Sangini B; Green, Isabel C; Giuntoli, Robert L; Winder, Abigail D; Fader, Amanda N

    2013-01-01

    Our objectives were to compare the utility of learning a suturing task on the virtual reality da Vinci Skills Simulator versus the da Vinci Surgical System dry laboratory platform and to assess user satisfaction among novice robotic surgeons. Medical trainees were enrolled prospectively; one group trained on the virtual reality simulator, and the other group trained on the da Vinci dry laboratory platform. Trainees received pretesting and post-testing on the dry laboratory platform. Participants then completed an anonymous online user experience and satisfaction survey. We enrolled 20 participants. Mean pretest completion times did not significantly differ between the 2 groups. Training with either platform was associated with a similar decrease in mean time to completion (simulator platform group, 64.9 seconds [P = .04]; dry laboratory platform group, 63.9 seconds [P < .01]). Most participants (58%) preferred the virtual reality platform. The majority found the training "definitely useful" in improving robotic surgical skills (mean, 4.6) and would attend future training sessions (mean, 4.5). Training on the virtual reality robotic simulator or the dry laboratory robotic surgery platform resulted in significant improvements in time to completion and economy of motion for novice robotic surgeons. Although there was a perception that both simulators improved performance, there was a preference for the virtual reality simulator. Benefits unique to the simulator platform include autonomy of use, computerized performance feedback, and ease of setup. These features may facilitate more efficient and sophisticated simulation training above that of the conventional dry laboratory platform, without loss of efficacy.

  15. Systematic review of operative outcomes of robotic surgical procedures performed with endoscopic linear staplers or robotic staplers.

    PubMed

    Gutierrez, Mario; Ditto, Richard; Roy, Sanjoy

    2018-05-09

    A comprehensive review of operative outcomes of robotic surgical procedures performed with the da Vinci robotic system using either endoscopic linear staplers (ELS) or robotic staplers is not available in the published literature. We conducted a literature search to identify publications of robotic surgical procedures in all specialties performed with either ELS or robotic staplers. Twenty-nine manuscripts and six abstracts with relevant information on operative outcomes published from January 2011 to September 2017 were identified. Given the relatively recent market release of robotic staplers in 2014, comparative perioperative clinical outcomes data on the performance of ELS vs. robotic staplers in robotic surgery is very sparse in the published literature. Only three comparative studies of surgeries with the da Vinci robotic system plus ELS vs. da Vinci plus robotic staplers were identified; two in robotic colorectal surgery and the other in robotic gastric bypass surgery. These comparative studies illustrate some nuances in device design and usability, which may impact outcomes and cost, and therefore may be important to consider when selecting the appropriate stapling technologies/technique for different robotic surgeries. Comparative perioperative data on the use of ELS vs. robotic staplers in robotic surgery is scarce (three studies), and current literature identifies both types of devices as safe and effective. Given the longer clinical history of ELS and its relatively more robust evidence base, there may be trade-offs to consider before switching to robotic staplers in certain robotic procedures. However, this literature review may serve as an initial reference for future research.

  16. Explorers with a Mission.

    ERIC Educational Resources Information Center

    Sweeney, Patricia James

    1991-01-01

    Offers brief summaries of contributions made by several of Christopher Columbus's contemporaries, including Nicholas Cusa, Leonardo da Vinci, Michelangelo Buonarroti, Nicholas Copernicus, Johannes Gutenberg, Sir Thomas More, Desiderius Erasmus, and John Colet. Urges modern Catholic educators to learn from these risk takers and visionaries. (DMM)

  17. Speculation and Historical Interpretation for Fifth and Sixth Graders.

    ERIC Educational Resources Information Center

    Schneider, Elizabeth; Gregory, Leslie A.

    2000-01-01

    Describes a unit for fifth- and sixth-grade students that helps develop critical thinking skills. Explains that students read the book, "Leonardo da Vinci" (Diane Stanley), to develop their historical interpretation skills and demonstrate that there is not just one right answer in history. (CMK)

  18. Perception, Cognition, and Visualization.

    ERIC Educational Resources Information Center

    Arnheim, Rudolf

    1991-01-01

    Described are how pictures can combine aspects of naturalistic representation with more formal shapes to enhance cognitive understanding. These "diagrammatic" shapes derive from geometrical elementary and thereby bestow visual concreteness to concepts conveyed by the pictures. Leonardo da Vinci's anatomical drawings are used as examples…

  19. On the Developing Role of Physical Models in Engineering Design Education

    ERIC Educational Resources Information Center

    Green, Graham; Smrcek, Ladislav

    2006-01-01

    Recent research, undertaken using participative observation methods within the Leonardo Da Vinci project "Open-Dynamic-Design", provides evidence that EU industrial practice continues to value the flexibility of physical models across a range of disciplines. This research is placed within the philosophical educational framework…

  20. Specific Reading Disability in Historically Famous Persons.

    ERIC Educational Resources Information Center

    Aaron, P. G.; And Others

    1988-01-01

    The possibility that four famous men--Thomas Alva Edison, Woodrow Wilson, Hans Christian Andersen, and Leonardo da Vinci--might have been reading disabled is considered by examining information concerning: (1) biographical records, (2) cognitive characteristics, (3) neuropsychological characteristics, and (4) biological characteristics. (Author/DB)

  1. Avoiding Steric Congestion in Dendrimer Growth through Proportionate Branching. A Twist on da Vinci's Rule of Tree Branching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Xuyi; Taraban, Marc B.; Hyland, Laura L.

    2012-10-05

    In making defect-free macromolecules, the challenge occurs during chemical synthesis. This challenge is especially pronounced in dendrimer synthesis where exponential growth quickly leads to steric congestion. To overcome this difficulty, proportionate branching in dendrimer growth is proposed. In proportionate branching, both the number and the length of branches increase exponentially but in opposite directions to mimic tree growth. The effectiveness of this strategy is demonstrated through the synthesis of a fluorocarbon dendron containing 243 chemically identical fluorine atoms with a MW of 9082 Da. Monodispersity is confirmed by nuclear magnetic resonance spectroscopy, mass spectrometry, and small-angle X-ray scattering. Moreover, growingmore » different parts proportionately, as nature does, could be a general strategy to achieve defect-free synthesis of macromolecules.« less

  2. Math and the Mona Lisa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atalay, Bulent

    2004-05-03

    Bulent Atalay discusses content from his book entitled "Math and the Mona Lisa" which covers Leonardo Da Vinci and how he combined his love of science, math, and art to draw dramatic conclusions about the natural world. He also describes how mathematics influences art and architecture.

  3. How Is a Matisse Like a Mondrian?

    ERIC Educational Resources Information Center

    Brock, Barbara

    1991-01-01

    Reviews St. Philip Neri Elementary School's (Omaha, Nebraska) use of an art education approach incorporating aesthetics and art history, criticism, and production. Describes lessons on Matisse and Mondrian (kindergarten), Rouault's "Portrait of a Clown" (fifth grade) and da Vinci's "Last Supper" (second grade). Recommends the approach for…

  4. A Humanities and Medicine Program for Faculty.

    ERIC Educational Resources Information Center

    Loftus, Loretta S.; And Others

    1991-01-01

    The da Vinci Society provides a format for integration of the humanities, arts, medical education, and clinical practice. The critical discussion group, whose meetings' atmosphere is informal and collegial, includes basic science faculty, academic clinicians, private practice physicians, allied health personnel, and occasional visiting artists.…

  5. Looking/Learning Drawing: Trees.

    ERIC Educational Resources Information Center

    Hurwitz, Al; Blume, Sharon

    1985-01-01

    Secondary students are asked to study and compare three reproductions--Van Gogh's "Grove of Cypresses," Da Vinci's "Study of a Tree," and Mondrian's "Tree II." The activity will help students develop their powers of observation and analysis, powers that can be applied to their own drawings. (RM)

  6. Mobile Distance Learning with PDAs: Development and Testing of Pedagogical and System Solutions Supporting Mobile Distance Learners

    ERIC Educational Resources Information Center

    Rekkedal, Torstein; Dye, Aleksander

    2007-01-01

    The article discusses basic teaching-learning philosophies and experiences from the development and testing of mobile learning integrated with the online distance education system at NKI (Norwegian Knowledge Institute) Distance Education. The article builds on experiences from three European Union (EU) supported "Leonardo da Vinci"…

  7. Artsmarts.

    ERIC Educational Resources Information Center

    Greenman, Geri

    2000-01-01

    Provides information on Leonardo da Vinci, Michelangelo, and Honore Daumier's "Rue Transonian." Describes an art activity in which students in an advanced drawing class reproduce a famous drawing in the same medium as the original, make the composition contemporary, and include themselves in the composition. (CMK)

  8. Robotics in cardiac surgery: the Istanbul experience.

    PubMed

    Sagbas, Ertan; Akpinar, Belhhan; Sanisoglu, Ilhan; Caynak, Baris; Guden, Mustafa; Ozbek, Ugur; Bayramoglu, Zehra; Bayindir, Osman

    2006-06-01

    Robots are sensor-based tools capable of performing precise, accurate and versatile actions. Initially designed to spare humans from risky tasks, robots have progressed into revolutionary tools for surgeons. Tele-operated robots, such as the da Vinci (Intuitive Surgical, Mountain View, CA), have allowed cardiac procedures to start benefiting from robotics as an enhancement to traditional minimally invasive surgery. The aim of this text was to discuss our experience with the da Vinci system during a 12 month period in which 61 cardiac patients were operated on. There were 59 coronary bypass patients (CABG) and two atrial septal defect (ASD) closures. Two patients (3.3%) had to be converted to median sternotomy because of pleural adhesions. There were no procedure- or device-related complications. Our experience suggests that robotics can be integrated into routine cardiac surgical practice. Systematic training, team dedication and proper patient selection are important factors that determine the success of a robotic surgery programme. Copyright 2006 John Wiley & Sons, Ltd.

  9. [Robotic splenectomy--a personal view].

    PubMed

    Vasilescu, C

    2010-01-01

    Until now 40 robotic splenectomies were performed in our department, the first case being done on February 25, 2008. Our data show that robotic splenectomy with the DaVinci surgical system is technically feasible and safe, with good results and without complications. The main advantages are a better tridimensional view and an increased versatility of the surgical instruments. The DaVinci system allows an accurate dissection around the splenic hilum and preservation of the splenic remnant vessels in partial splenectomy. Robotic splenectomy will probably not replace the laparoscopic splenectomy for the most common indications like ITP, hemolytic anemia. It may be a very useful surgical tool in difficult splenectomy: partial splenectomy, splenectomy in liver cirrhosis, splenic tumors or malignant hemopathies. In these cases the robotic approach may shorten the operative time, decrease the blood loss and the risk of remorrhagic complications during surgery and even make possible a minimally invasive splenectomy very difficult to be performed by classical laparoscopy.

  10. “Five on a dice” port placement for robot-assisted thoracoscopic right upper lobectomy using robotic stapler

    PubMed Central

    Chan, Edward Y.

    2017-01-01

    Early versions of the da Vinci robot system (S and Si) have been used to perform pulmonary lung resection with severe limitations. The lack of a vascular robot stapler required the presence of a trained bedside assistant whose role was to place, manipulate and fire the stapler around major vascular structures. Thus, the techniques developed for the Si robot required a skilled bedside assistant to perform stapling of the hilar structure and manipulation of the lung. With the advent of the da Vinci Xi system with a vascular robot stapler, we postulated that we could develop a new port placement and technique to provide total control for the surgeon during the pulmonary lung resection. We found that the “five on a dice” port placement and technique allows for minimal assistance during the lobectomy with full control by the surgeon. This technique uses the full capability of the Xi robot to make the robot-assisted lobectomy a safe and ergonomic operation. PMID:29312746

  11. "Five on a dice" port placement for robot-assisted thoracoscopic right upper lobectomy using robotic stapler.

    PubMed

    Kim, Min P; Chan, Edward Y

    2017-12-01

    Early versions of the da Vinci robot system (S and Si) have been used to perform pulmonary lung resection with severe limitations. The lack of a vascular robot stapler required the presence of a trained bedside assistant whose role was to place, manipulate and fire the stapler around major vascular structures. Thus, the techniques developed for the Si robot required a skilled bedside assistant to perform stapling of the hilar structure and manipulation of the lung. With the advent of the da Vinci Xi system with a vascular robot stapler, we postulated that we could develop a new port placement and technique to provide total control for the surgeon during the pulmonary lung resection. We found that the "five on a dice" port placement and technique allows for minimal assistance during the lobectomy with full control by the surgeon. This technique uses the full capability of the Xi robot to make the robot-assisted lobectomy a safe and ergonomic operation.

  12. Distance Learning. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This brochure, part of a series about good practices in vocational training in the European Union, describes 12 projects that use distance learning to promote lifelong learning in adults. The projects and their countries of origin are as follows: (1) 3D Project, training in the use of IT tools for 3D simulation and animation and practical…

  13. Implementation of the Automated Numerical Model Performance Metrics System

    DTIC Science & Technology

    2011-09-26

    question. As of this writing, the DSRC IBM AIX machines DaVinci and Pascal, and the Cray XT Einstein all use the PBS batch queuing system for...3.3). 12 Appendix A – General Automation System This system provides general purpose tools and a general way to automatically run

  14. Towards an Analytic Foundation for Network Architecture

    DTIC Science & Technology

    2010-12-31

    SUPPLEMENTARY NOTES N/A 14. ABSTRACT In this project, we develop the analytic tools of stochastic optimization for wireless network design and apply them...and Mung Chiang, “ DaVinci : Dynamically Adaptive Virtual Networks for a Customized Internet,” in Proc. ACM SIGCOMM CoNext Conference, December 2008

  15. Kinderet: Developing Training for Early Childhood Educators in Information and Communications Technology (ICT) In Bulgaria, England, Portugal, Spain and Sweden

    ERIC Educational Resources Information Center

    Saude, S.; Carioca, V.; Siraj-Blatchford, J.; Sheridan, S.; Genov, K.; Nuez, R.

    2005-01-01

    In the European context the continuing training of early childhood educators in terms of information and communications technology (ICT) remains limited and is in need of development. The KINDERET project has been funded through the European Commission's "Leonardo da Vinci" programme aimed to identify and understand the theoretical and…

  16. Autonomy-How much is too much

    DTIC Science & Technology

    2007-06-22

    throughout the ages Hero of Alexandria designed a number of water- and air-powered automata[3][4] Leonardo da Vinci designed and built a number...Verlag, 2006. [6] Benedict Sweeney. “Leonardo’s Hands.” http://www.leonardoshands.com/artman2/publish/ leonardos - robot-knight/index.shtml [7] Peter

  17. Toward image guided robotic surgery: system validation.

    PubMed

    Herrell, Stanley D; Kwartowitz, David Morgan; Milhoua, Paul M; Galloway, Robert L

    2009-02-01

    Navigation for current robotic assisted surgical techniques is primarily accomplished through a stereo pair of laparoscopic camera images. These images provide standard optical visualization of the surface but provide no subsurface information. Image guidance methods allow the visualization of subsurface information to determine the current position in relationship to that of tracked tools. A robotic image guided surgical system was designed and implemented based on our previous laboratory studies. A series of experiments using tissue mimicking phantoms with injected target lesions was performed. The surgeon was asked to resect "tumor" tissue with and without the augmentation of image guidance using the da Vinci robotic surgical system. Resections were performed and compared to an ideal resection based on the radius of the tumor measured from preoperative computerized tomography. A quantity called the resection ratio, that is the ratio of resected tissue compared to the ideal resection, was calculated for each of 13 trials and compared. The mean +/- SD resection ratio of procedures augmented with image guidance was smaller than that of procedures without image guidance (3.26 +/- 1.38 vs 9.01 +/- 1.81, p <0.01). Additionally, procedures using image guidance were shorter (average 8 vs 13 minutes). It was demonstrated that there is a benefit from the augmentation of laparoscopic video with updated preoperative images. Incorporating our image guided system into the da Vinci robotic system improved overall tissue resection, as measured by our metric. Adding image guidance to the da Vinci robotic surgery system may result in the potential for improvements such as the decreased removal of benign tissue while maintaining an appropriate surgical margin.

  18. Effects of Visual Force Feedback on Robot-Assisted Surgical Task Performance

    PubMed Central

    Reiley, Carol E.; Akinbiyi, Takintope; Burschka, Darius; Chang, David C.; Okamura, Allison M.; Yuh, David D.

    2009-01-01

    Background Direct haptic (force or tactile) feedback is negligible in current surgical robotic systems. The relevance of haptic feedback in robot-assisted performances of surgical tasks is controversial. We studied the effects of visual force feedback (VFF), a haptic feedback surrogate, on tying surgical knots with fine sutures similar to those used in cardiovascular surgery. Methods Using a modified da Vinci robotic system (Intuitive Surgical, Inc.) equipped with force-sensing instrument tips and real-time VFF overlays in the console image, ten surgeons each tied 10 knots with and 10 knots without VFF. Four surgeons had significant prior da Vinci experience while the remaining six surgeons did not. Performance parameters, including suture breakage and secure knots, peak and standard deviation of applied forces, and completion times using 5-0 silk sutures were recorded. Chi-square and Student’s t-test analyses determined differences between groups. Results Among surgeon subjects with robotic experience, no differences in measured performance parameters were found between robot-assisted knot ties executed with and without VFF. Among surgeons without robotic experience, however, VFF was associated with lower suture breakage rates, peak applied forces, and standard deviations of applied forces. VFF did not impart differences in knot completion times or loose knots for either surgeon group. Conclusions VFF resulted in reduced suture breakage, lower forces, and decreased force inconsistencies among novice robotic surgeons, although elapsed time and knot quality were unaffected. In contrast, VFF did not affect these metrics among experienced da Vinci surgeons. These results suggest that VFF primarily benefits novice robot-assisted surgeons, with diminishing benefits among experienced surgeons. PMID:18179942

  19. 2D–3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery

    PubMed Central

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J.; Sorger, Jonathan M.; Armand, Mehran; Taylor, Russell H.

    2015-01-01

    Purpose C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D–3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Methods Intensity-based 2D–3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. Results The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ : ~ 30°. The two C-arm systems provided TREmean ≤ 2.5 mm and TREmean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). Conclusions C-arm 3D localization from dual 2D–3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system. PMID:25503592

  20. Bringing History Alive in the Classroom!

    ERIC Educational Resources Information Center

    McRae, Lee, Ed.

    1996-01-01

    This document consists of the first four issues of a serial publication, "Bringing History Alive in the Classroom!" The volumes focus on: (1) "A Sampling of Renaissance Instruments," which includes: information on Christopher Columbus, Leondardo da Vinci, and William Shakespeare, a timeline from the middle ages through the renaissance, Queen…

  1. Leonardo's Rule, Self-Similarity, and Wind-Induced Stresses in Trees

    NASA Astrophysics Data System (ADS)

    Eloy, Christophe

    2011-12-01

    Examining botanical trees, Leonardo da Vinci noted that the total cross section of branches is conserved across branching nodes. In this Letter, it is proposed that this rule is a consequence of the tree skeleton having a self-similar structure and the branch diameters being adjusted to resist wind-induced loads.

  2. The Challenge of Assessing Project-Based Learning

    ERIC Educational Resources Information Center

    Boss, Suzie

    2012-01-01

    For their ambitious project, called America at War, high school juniors at Da Vinci Charter Academy in the Davis (California) Joint Unified School District didn't just study history. They became historians. Their project offers compelling evidence of what students can accomplish through project-based learning (PBL), an instructional approach that…

  3. Surgical Technology Integration with Tools for Cognitive Human Factors (STITCH)

    DTIC Science & Technology

    2010-10-01

    Measurement Tool We conducted another round of data collection using the daVinci Surgical System at the University of Kentucky Hospital in May. In this...9 3. Tools and Display Technology...considering cognitive and environmental factors such as mental workload, stress, situation awareness, and level of comfort with complex tools . To

  4. Structural Information Retention in Visual Art Processing.

    ERIC Educational Resources Information Center

    Koroscik, Judith Smith

    The accuracy of non-art college students' longterm retention of structural information presented in Leonardo da Vinci's "Mona Lisa" was tested. Seventeen female undergraduates viewed reproductions of the painting and copies that closely resembled structural attributes of the original. Only 3 of the 17 subjects reported having viewed a reproduction…

  5. Kids as Curators: Virtual Art at the Seattle Museum.

    ERIC Educational Resources Information Center

    Scanlan, Laura Wolff

    2000-01-01

    Discusses the use of technology at the Seattle Art Museum (Washington). Includes a Web site that enables students in grades six through ten to act as curators and offers integrations of technology in the exhibition "Leonardo Lives: The Codex Leicester and Leonardo da Vinci's Legacy of Art and Science." (CMK)

  6. The Need for High Speed in Next Generation Rotorcraft

    DTIC Science & Technology

    2012-03-01

    ROTORCRAFT From the earliest thought of manned flight the helicopter was considered as a viable option to satisfy the requirement for flight. Leonardo Da... Vinci first dreamed of the helicopter flight concept in the year 1480. His adaption of the flying machine, named the "Helical Air Screw,” used the

  7. Tests of stellar model atmospheres by optical interferometry. VLTI/VINCI limb-darkening measurements of the M4 giant ψ Phe

    NASA Astrophysics Data System (ADS)

    Wittkowski, M.; Aufdenberg, J. P.; Kervella, P.

    2004-01-01

    We present K-band interferometric measurements of the limb-darkened (LD) intensity profile of the M 4 giant star ψ Phoenicis obtained with the Very Large Telescope Interferometer (VLTI) and its commissioning instrument VINCI. High-precision squared visibility amplitudes in the second lobe of the visibility function were obtained employing two 8.2 m Unit Telescopes (UTs). This took place one month after light from UTs was first combined for interferometric fringes. In addition, we sampled the visibility function at small spatial frequencies using the 40 cm test siderostats. Our measurement constrains the diameter of the star as well as its center-to-limb intensity variation (CLV). We construct a spherical hydrostatic PHOENIX model atmosphere based on spectrophotometric data from the literature and compare its CLV prediction with our interferometric measurement. We compare as well CLV predictions by plane-parallel hydrostatic PHOENIX, ATLAS 9, and ATLAS 12 models. We find that the Rosseland angular diameter as predicted by comparison of the spherical PHOENIX model with spectrophotometry is in good agreement with our interferometric diameter measurement. The shape of our measured visibility function in the second lobe is consistent with all considered PHOENIX and ATLAS model predictions, and is significantly different to uniform disk (UD) and fully darkened disk (FDD) models. We derive high-precision fundamental parameters for ψ Phe, namely a Rosseland angular diameter of 8.13 ± 0.2 mas, with the Hipparcos parallax corresponding to a Rosseland linear radius R of 86 ± 3 R⊙, and an effective temperature of 3550 ± 50 K, with R corresponding to a luminosity of \\log L/L⊙=3.02 ± 0.06. Together with evolutionary models, these values are consistent with a mass of 1.3 ± 0.2 M⊙, and a surface gravity of \\log g = 0.68 ± 0.11. Based on public data released from the European Southern Observatory VLTI obtained from the ESO/ST-ECF Science Archive Facility. The VLTI

  8. Reflection by Porro Prisms

    NASA Astrophysics Data System (ADS)

    Greenslade, Thomas B.

    2010-04-01

    Students all know that reflection from a plane mirror produces an image that is reversed right to left and so cannot be read by anyone but Leonardo da Vinci, who kept his notes in mirror writing. A useful counter-example is the Porro prism, which produces an image that is not reversed.

  9. Fluid Dynamic Aspects of Wind Energy Conversion

    DTIC Science & Technology

    1979-07-01

    numbers, i.e. for relatively large-scale turbines). This might be acceptable for a single production unit (reduction of tooling costs), but looses its...Behind a Wing via Comparison of Measurements and Calculations. NLR TR 74063 U (July 1974). 4.17 Foley, W.M.: From DaVinci to the Piesent - a Review of

  10. Art, Anatomy, and Medicine: Is There a Place for Art in Medical Education?

    ERIC Educational Resources Information Center

    Bell, Lawrence T. O.; Evans, Darrell J. R.

    2014-01-01

    For many years art, anatomy and medicine have shared a close relationship, as demonstrated by Leonardo da Vinci's anatomical drawings and Andreas Vesalius' groundbreaking illustrated anatomical textbook from the 16th century. However, in the modern day, can art truly play an important role in medical education? Studies have suggested that art can…

  11. Comparison of Expert-Based and Empirical Evaluation Methodologies in the Case of a CBL Environment: The ''Orestis'' Experience

    ERIC Educational Resources Information Center

    Karoulis, Athanasis; Demetriadis, Stavros; Pombortsis, Andreas

    2006-01-01

    This paper compares several interface evaluation methods applied in the case of a computer based learning (CBL) environment, during a longitudinal study performed in three European countries, Greece, Germany, and Holland, and within the framework of an EC funded Leonardo da Vinci program. The paper firstly considers the particularities of the CBL…

  12. The Renaissance Culture and the Arts. Grades 3-6, The Time Traveler Series.

    ERIC Educational Resources Information Center

    Pofahl, Jane

    This resource guide encourages grade 3-6 students to explore the social structure, government, culture and art forms, scientific discoveries, and historic personalities of the European Renaissance. The work is organized into 10 topics: (1) The Renaissance; (2) Art; (3) Leonardo da Vinci; (4) The Medicis; (5) Michelangelo; (6) Printing; (7) Music;…

  13. Humanities in the High School Classroom.

    ERIC Educational Resources Information Center

    Stawski, Conrad

    A humanities course that teaches an appreciation of tradition and culture through the visual arts includes consideration of contemporary art as well as classic paintings and sculpture. Study of Leonardo DaVinci's "Last Supper" provides an exercise in the intellectual approach to religious painting, while the portrait of Mona Lisa by the same…

  14. Design of the central region for axial injection in the VINCY cyclotron

    NASA Astrophysics Data System (ADS)

    Milinković, Ljiljana; Toprek, Dragan

    1996-02-01

    This paper describes the design of the central region for h = 1, h = 2 and h = 4 modes of acceleration in the VINCY cyclotron. The result which is worth reported in that the central region is unique and compatible with the three above mentioned harmonic modes of operation. Only one spiral type inflector will be used. The central region is designed to operate with two external ion sources: (a) an ECR ion source with the maximum extraction voltage of 25 kV for heavy ions, and (b) a multicusp ion source with the maximum extraction voltage of 30 kV for H - and D - ions. Heavy ions will be accelerated by the second and fourth harmonics, D - ions by the second harmonic and H - ions by the first harmonic of the RF field. The central region is equipped with an axial injection system. The electric field distribution in the inflector and in the four acceleration gaps has been numerically calculated from an electric potential map produced by the program RELAX3D. The geometry of the central region has been tested with the computations of orbits carried out by means of the computer code CYCLONE. The optical properties of the spiral inflector and the central region were studied by using the programs CASINO and CYCLONE respectively. We have also made an effort to minimize the inflector fringe field using the RELAX3D program.

  15. ROBOTIC ASSISTED SINGLE SITE FOR BILATERAL INGUINAL HERNIA REPAIR.

    PubMed

    Bosi, Henrique Rasia; Guimarães, José Ricardo; Cavazzola, Leandro Totti

    2016-01-01

    The inguinal hernia is one of the most frequent surgical diseases, being frequent procedure and surgeon´s everyday practice. To present technical details in making hernioplasty using robotic equipment on bilateral inguinal hernia repair with single port and preliminary results with the method. The bilateral inguinal hernia repair was performed by using the Single-Site(c) Da Vinci Surgical Access Platform to the abdominal cavity and the placement of clamps. This technique proved to be effective for inguinal hernia and have more aesthetic result when compared to other techniques. Inguinal hernia repair robot-assisted with single-trocar is feasible and effective. However, still has higher costs needing surgical team special training. A hérnia inguinal é uma das doenças cirúrgicas mais frequentes, tornando-a procedimento frequente e do cotidiano do cirurgião. Apresentar detalhes da técnica da hernioplastia inguinal bilateral robótica por single-site e resultados preliminares com o método. Foi realizada hernioplastia inguinal bilateral assistida por robô, utilizando-se da Vinci Single-Site(c) Surgical Platform para acesso a cavidade abdominal e colocação das pinças. Esta técnica demonstrou-se efetiva para correção da hérnia inguinal, além de apresentar melhor resultado estético quando comparado às outras técnicas. A hernioplastia inguinal assistida por robô com trocarte único é viável e eficaz. Contudo, ainda apresenta custos mais elevados e necessidade de treinamento especial por parte da equipe cirúrgica.

  16. [Geometry of laparoscopy, telesurgery, training and telementoring].

    PubMed

    Rassweiler, J; Frede, T

    2002-03-01

    Laparoscopic surgery in general is handicapped by the reduction of the range of motion from 6 to 4 degrees of freedom. This has a major impact on technically difficult procedures such as laparoscopic radical prostatectomy. Solutions for this problem include understanding the geometry of laparoscopy with sophisticated training programs, but also newly developed surgical robots, computer simulators, and telementoring. This article evaluates the value of these alternatives based on own experience and an analysis of the current literature. Our experience with robot-assisted surgery includes 244 laparoscopic radical prostatectomies using a voice-controlled camera arm (AESOP) and 6 telesurgical interventions with the da Vinci system. Additionally, experimental studies were performed focussing on the geometry of laparoscopy and new training concepts such as perfused pelvitrainers and computer simulation. Three-dimensional systems have not yet proved to be effective due to handling problems such as shutter glasses, video helmets, or reduced brightness. At present, there are only two robotic surgical systems (ZEUS, da Vinci) in clinical use for telesurgery, of which only the da Vinci provides stereovision and all 6 degrees of freedom (DOF). In the meantime, more than 100 laparoscopic radical prostatectomies have been performed with this system. However, there was no evidence of any advantages over the conventional laparoscopic approach. The ZEUS in combination with the telecommunication system SOKRATES is the only device that enables telemanipulation and telementoring over long distances (i.e., transatlantic). Robotic surgery represents a turning point in surgical research. However, broad use of robotic systems is limited mainly because of high investment and running costs. Whereas audiovisual telementoring will play a clear role in future training concepts, the need for telemanipulation or telesurgery has not yet been clarified.

  17. Mentoring console improves collaboration and teaching in surgical robotics.

    PubMed

    Hanly, Eric J; Miller, Brian E; Kumar, Rajesh; Hasser, Christopher J; Coste-Maniere, Eve; Talamini, Mark A; Aurora, Alexander A; Schenkman, Noah S; Marohn, Michael R

    2006-10-01

    One of the most significant limitations of surgical robots has been their inability to allow multiple surgeons and surgeons-in-training to engage in collaborative control of robotic surgical instruments. We report the initial experience with a novel two-headed da Vinci surgical robot that has two collaborative modes: the "swap" mode allows two surgeons to simultaneously operate and actively swap control of the robot's four arms, and the "nudge" mode allows them to share control of two of the robot's arms. The utility of the mentoring console operating in its two collaborative modes was evaluated through a combination of dry laboratory exercises and animal laboratory surgery. The results from surgeon-resident collaborative performance of complex three-handed surgical tasks were compared to results from single-surgeon and single-resident performance. Statistical significance was determined using Student's t-test. Collaborative surgeon-resident swap control reduced the time to completion of complex three-handed surgical tasks by 25% compared to single-surgeon operation of a four-armed da Vinci (P < 0.01) and by 34% compared to single-resident operation (P < 0.001). While swap mode was found to be most helpful during parts of surgical procedures that require multiple hands (such as isolation and division of vessels), nudge mode was particularly useful for guiding a resident's hands during crucially precise steps of an operation (such as proper placement of stitches). The da Vinci mentoring console greatly facilitates surgeon collaboration during robotic surgery and improves the performance of complex surgical tasks. The mentoring console has the potential to improve resident participation in surgical robotics cases, enhance resident education in surgical training programs engaged in surgical robotics, and improve patient safety during robotic surgery.

  18. Robotic single port cholecystectomy (R-LESS-C): experience in 36 patients.

    PubMed

    Uras, Cihan; Böler, Deniz Eren; Ergüner, Ilknur; Hamzaoğlu, Ismail

    2014-07-01

    Laparoendoscopic single-site surgery (LESS) has emerged as a result of a search for "pain-less" and "scar-less" surgery. Laparoendoscopic single-site cholecystectomy (LESS-C) is probably the most common application in general surgery, although it harbors certain limitations. It was proposed that the da Vinci Single-Site (Si) robotic system may overcome some of the difficulties experienced during LESS, providing three dimensional views and the ability to work in a right-handed fashion. Thirty-six robotic single port cholecystectomies (R-LESS-C) performed with the da Vinci Si robotic system are evaluated in this paper R-LESS-C performed in 36 patients were reviewed. The data related to the perioperative period (i.e., anesthesia time, operation time, docking time, and console time) was recorded prospectively, whereas the hospitalization period, postoperative visual analogue scale (VAS) pain scores were collected retrospectively. A total number of 36 patients, with a mean age of 40.1 years (21-64 years), underwent R-LESS-C. There were five men and 31 women. The mean anesthesia and operation times were 79.3 minutes (45-130 minutes) and 61.8 minutes (34-110 minutes), respectively. The mean docking time was 9.8 minutes (4-30 minutes) and the mean console time was 24.9 minutes (7-60 minutes). The mean hospital stay was 1.05 days (1-2 days) and the mean pain score (VAS) was 3.6 (2-8) in the first 24 hours. Incisional hernia was recorded in one patient. R-LESS-C can be performed reliably with acceptable operative times and safety. The da Vinci Si robotic system may ease LESS-C. Two issues should be considered for routine use: expensive resources are needed and the incidence of incisional hernia may increase. Copyright © 2013. Published by Elsevier B.V.

  19. Everyday Electrical Engineering: A One-Week Summer Academy Course for High School Students

    ERIC Educational Resources Information Center

    Mehrizi-Sani, A.

    2012-01-01

    A summer academy is held for grade 9-12 high school students at the University of Toronto, Toronto, ON, Canada, every year. The academy, dubbed the Da Vinci Engineering Enrichment Program (DEEP), is a diverse program that aims to attract domestic and international high school students to engineering and sciences (and possibly recruit them). DEEP…

  20. Hartford Hospital surgeons share publicity with robot 'assistants.'.

    PubMed

    Botvin, Judith D

    2004-01-01

    Hartford Hospital, Hartford, Conn. finds some patients gravitate to Boston or New York City for high-tech procedures. Being the first Connecticut hospital with the daVinci Robotic Surgery System, it developed an advertising campaign emphasizing high-tech surgery with the human touch. Hartford also broadcast a robotic prostatectomy on its popular live webcast series.

  1. Mathematical Fiction for Senior Students and Undergraduates: Novels, Plays, and Film

    ERIC Educational Resources Information Center

    Padula, Janice

    2006-01-01

    Mathematical fiction has probably existed since ideas have been written down and certainly as early as 414 BC (Kasman, 2000). Mathematical fiction is a recently rediscovered and growing literature, as sales of the novels: "The Curious Incident of the Dog in the Night-time" (Haddon, 2003) and "The Da Vinci Code" (Brown, 2004) attest. Science…

  2. The Xmath Integration Algorithm

    ERIC Educational Resources Information Center

    Bringslid, Odd

    2009-01-01

    The projects Xmath (Bringslid and Canessa, 2002) and dMath (Bringslid, de la Villa and Rodriguez, 2007) were supported by the European Commission in the so called Minerva Action (Xmath) and The Leonardo da Vinci programme (dMath). The Xmath eBook (Bringslid, 2006) includes algorithms into a wide range of undergraduate mathematical issues embedded…

  3. Putting Dreyfus into Action: The European Credit Transfer System

    ERIC Educational Resources Information Center

    Markowitsch, Jorg; Luomi-Messerer, Karin; Becker, Matthias; Spottl, Georg

    2008-01-01

    Purpose: The purpose of this article is to look closely at the development of a European Credit Transfer System for Vocational Education and Training (ECVET). The European Commission, together with the member States, are working on it and several pilot projects have been initiated within the Leonardo da Vinci Programme of the European Commission.…

  4. The quarter-power scaling model does not imply size-invariant hydraulic resistance in plants

    Treesearch

    Annikki Makela; Harry T. Valentine

    2006-01-01

    West, Brown, and Enquist (1997, 1999) propose an integrated model of the structure and allometry of plant vascular systems, which has come to be known as the 'WBE model' (Enquist, 2002). The WBE model weaves together area-preserving branching (Leonardo da Vinci), elastic similarity (Greenhill, 1881), the constant ratio of foliage mass to sapwood area (...

  5. [Robotic assistance in gynaecological surgery: State-of-the-art].

    PubMed

    Monsarrat, N; Collinet, P; Narducci, F; Leblanc, E; Vinatier, D

    2009-05-01

    From the Automated Endoscopic System for Optimal Positioning (AESOP), a robotic arm which operates the laparoscope, to the robots Zeus and da Vinci, robotic assistance in gynaecological endoscopic surgery has continuously evolved for the last fifteen years or so. It has brought about new technical advancements: the last generation robots offer a steady three-dimensional image, improved instrument dexterity and precision, higher ergonomics and comfort for the surgeon. The da Vinci robotic system has been used without evincing any specific morbidity in various cases, notably for tubal reanastomosis, myomectomy, hysterectomy, pelvic and para-aortic lymphadenectomy or sacrocolpopexy amongst others. Robotic assistance in gynaecology is thus feasible. Like conventional laparoscopic surgery, it allows decreased blood loss and morbidity as well as shorter hospital stay, as compared to laparotomy. It might indeed allow many surgical teams to perform minimally invasive surgical procedures which they were not used to performing by laparoscopy. Randomized prospective studies are needed to define its indications more precisely. Besides, its medico-financial impact should be evaluated too.

  6. The Minimally Invasive Manipulator: an ergonomic and economic non-robotic alternative for endoscopy?

    PubMed

    Bosma, Jesse; Aarts, Sanne; Jaspers, Joris

    2015-02-01

    Since the da Vinci robotic system was introduced, it has been reported to have ergonomic advantages over conventional laparoscopy (COV). High investments associated with this system challenged us to design a more economical, mechanical alternative for improvement of laparoscopic ergonomics: the Minimally Invasive Manipulator (MIM). An earlier reported MIM prototype was investigated. Its shortcomings were input for the establishment of design criteria for a new prototype. A new prototype was developed, aiming at improved intuitiveness and ergonomics. The handle and instrument tip were redesigned and the parallelogram mechanism was converted from linear moving parts to mainly rotating parts. The new prototype was tested by a panel of experts and novices during an indicative ergonomic experiment. A major advantage of the MIM seems to be the possibility to perform laparoscopic surgery in a sitting position, in line with the working axis, instead of standing at the side of the patient. At an estimated cost level of 10% of the da Vinci system, the MIM can be an economical alternative for the enhancement of laparoscopy ergonomics. However, further development for clinical feasibility is necessary.

  7. A Picture is Worth a Thousand Words: Art and Medicine.

    PubMed

    Dahan, Shani; Shoenfeld, Yehuda

    2017-12-01

    Medical practice is a form of art, with each complex detail essential to the welfare of the individuals in the care of the physician. Art and medicine have shared a close relationship in a variety of ways for centuries, as demonstrated by anatomical drawings and textbooks from the 16th century. Leonardo da Vinci, driven by his fascination with the details of the human body and how it functioned, succeeded in creating an anatomical model of the cerebral ventricles and the aorta using molten wax and a glass structure, respectively (Heart and Its Blood Vessels). By using water that contained grass seeds, this experiment enabled him to study blood flow. da Vinci's engrossment with the complexity of the human body is reflected in many of his drawings, including the famous depiction of the human physique in his drawing of the Vitruvian Man. This drawing, which defines the ideal proportions of the human body and their correlation with geometry, is an example of how artistic and scientific objectives integrate with each other.

  8. Transoral robotic resection of selected parapharyngeal space tumors.

    PubMed

    Arshad, Hassan; Durmus, Kasim; Ozer, Enver

    2013-05-01

    Currently, transoral robotic surgery (TORS) with the daVinci robot is mainly used for squamous cell carcinoma of the oropharynx and supraglottic larynx. The safety, efficacy, and functional outcomes regarding this approach have previously been described. In addition to transoral resection of squamous cell carcinoma, we have found use for this technique in removing selected tumors of the parapharyngeal space. Three patients with benign or malignant tumors of the parapharyngeal space who underwent successful transoral resection using the daVinci robot were included in the study. In all three cases, complete tumor excision was achieved without any complication. None required conversion to an open procedure. Mean TORS operative time and intraoperative blood loss were 16.3 min and 4.7 mL, respectively. Inadequate oral exposure, involvement of the internal carotid artery, limited cervical spine mobility and large tumor size are the main limitations of this approach. Result indicates that magnified view, 3D visualization with the combination of the transoral robotic experience, allow en bloc resection of selected parapharyngeal space tumors located medial to the carotid sheath.

  9. Cryptographer

    ERIC Educational Resources Information Center

    Sullivan, Megan

    2005-01-01

    For the general public, the field of cryptography has recently become famous as the method used to uncover secrets in Dan Brown's fictional bestseller, The Da Vinci Code. But the science of cryptography has been popular for centuries--secret hieroglyphics discovered in Egypt suggest that code-making dates back almost 4,000 years. In today's…

  10. Reach for the Stars: Visions for Literacy Coaching Programs

    ERIC Educational Resources Information Center

    DeFord, Diane

    2012-01-01

    This brief by the Literacy Coaching Clearinghouse is about reaching for the stars--stories of vision and commitment from educators in small and large schools. Everyone knows of people who are held up as "visionaries" throughout history: Leonardo Da Vinci, Mahatma Gandhi, Jules Verne, Thomas Edison, Susan Anthony, or John Dewey, to name a few. The…

  11. Unraveling Theorists' Evaluation Reality

    ERIC Educational Resources Information Center

    Alkin, Marvin C.; Christie, Christina A.

    2005-01-01

    The theorists whose work appears in this issue have confronted the exercise presented to them in vastly different ways. The editors of this journal asked these theorists to consider how they would evaluate the Bunche-Da Vinci program, and to make and specify assumptions about the program context. The primary task, however, was to describe "a…

  12. Adventures in Modeling: Exploring Complex, Dynamic Systems with StarLogo.

    ERIC Educational Resources Information Center

    Colella, Vanessa Stevens; Klopfer, Eric; Resnick, Mitchel

    For thousands of years people from da Vinci to Einstein have created models to help them better understand patterns and processes in the world around them. Computers make it easier for novices to build and explore their own models and learn new scientific ideas in the process. This book introduces teachers and students to designing, creating, and…

  13. The Young Artist as Scientist: What Can Leonardo Teach Us?

    ERIC Educational Resources Information Center

    Pollman, Mary Jo

    2017-01-01

    This is the first in-depth look at the important connections between the arts and science specifically for early childhood education (pre-K-3rd grade). Highlighting their many commonalities, such as the processes involved in creative problem solving, the author draws on what we can learn from Leonardo da Vinci as the supreme artist-scientist.…

  14. Historical Scientific Models and Theories as Resources for Learning and Teaching: The Case of Friction

    ERIC Educational Resources Information Center

    Besson, Ugo

    2013-01-01

    This paper presents a history of research and theories on sliding friction between solids. This history is divided into four phases: from Leonardo da Vinci to Coulomb and the establishment of classical laws of friction; the theories of lubrication and the Tomlinson's theory of friction (1850-1930); the theories of wear, the Bowden and Tabor's…

  15. Nature Foil Reliefs

    ERIC Educational Resources Information Center

    Lane, Shaw J.

    2012-01-01

    Nature has always been a source of inspiration for artists across the centuries. Artists such as Leonardo da Vinci, Georgia O'Keeffe, Ansel Adams, and Andy Goldsworthy all drew inspiration for their work from nature. Seeds come from the dried pods, which when planted and cared for, bear fruit. In this article, the author describes how her…

  16. An Evaluation of the Training Needs of Staff in the Further Education Sector in the Republic of Ireland

    ERIC Educational Resources Information Center

    McNamara, Gerry; Mulcahy, Carmel; O'Hara, Joe

    2005-01-01

    This article examines the training needs of educators working in the further education (FE), adult education, and Second Chance sectors in the Republic of Ireland. The research on which it is based was funded jointly by the European Union Leonardo da Vinci Programme and the Department of Education and Science of Ireland and took place from 1998 to…

  17. The Future Development of the European Union Education, Training and Youth Programmes After 2006: A Public Consultation Document.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document launches a wide public consultation with all those involved in and with an interest in the European Union's (EU's) education, training, and youth programs called Socrates, Tempus, Leonardo da Vinci, and Youth for Europe. It is the first step toward preparing the new generation of programs to start in 2007 and will inform the…

  18. Building Systems: Passing Fad or Basic Tool?

    ERIC Educational Resources Information Center

    Rezab, Donald

    Building systems can be traced back to a 1516 A.D. project by Leonardo da Vinci and to a variety of prefabrication projects in every succeeding century. When integrated into large and repetitive spatial units through careful design, building systems can produce an architecture of the first order, as evidenced in the award winning design of…

  19. The Prelude to the Millennium: The Backstory of Digital Aesthetics

    ERIC Educational Resources Information Center

    Mayo, Sherry

    2008-01-01

    The artist and scientist have been depicted as polar opposites since Michelangelo claimed that Leonardo da Vinci was wasting time with foolish inventions while his art suffered. However, the artist taking on the role of the researcher has precedent. In the 1960s, Experiments in Art and Technology (E.A.T.), led by Bell Labs' engineer Billy Kluver,…

  20. Rotorcraft Conceptual Design Environment

    DTIC Science & Technology

    2009-10-01

    systems engineering design tool sets. The DaVinci Project vision is to develop software architecture and tools specifically for acquisition system...enable movement of that information to and from analyses. Finally, a recently developed rotorcraft system analysis tool is described. Introduction...information to and from analyses. Finally, a recently developed rotorcraft system analysis tool is described. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION

  1. Center of Cardiac Surgery Robotic Computerized Telemanipulation as Part of a Comprehensive Approach to Advanced Heart Care

    DTIC Science & Technology

    2011-10-01

    performance metrics; and development of Robotic OR Team training including crisis management. Q3: During the third quarter of this project, the...literature review for robot-assisted surgical skill training/performance metrics; development of Robotic OR Team training materials including crisis ... crisis management situations. Q2: Contract negotiations for the purchase of the da Vinci Skills Simulator are completed and we anticipate the

  2. Paths of Movement for Selected Body Segments During Typical Pilot Tasks

    DTIC Science & Technology

    1976-03-01

    11 Scope ........... ...................... 12 Past Human Motion Investigations ........... ... 13 Experimental Techniques in Human...of.literature has been generated during the past few decades in the field of human-motion recording and analysis. However, in most of these studies body...to meet the COMBIMAN model requirements. Past Human Motion Investigations The 15th century artist-scientist, Leonardo da Vinci, is generally credited

  3. OCT for Examination of Artwork

    NASA Astrophysics Data System (ADS)

    Targowski, Piotr; Iwanicka, Magdalena; Rouba, Bogumiła J.; Frosinini, Cecilia

    In this chapter the application of OCT to examination of objects of cultural heritage is given. The knowledge about the structure of the object of art is necessary both for inventory purposes and planning/monitoring of conservation-restoration treatments. Due to its noninvasiveness OCT is well suited for such applications. The major limitation is in the lack of transparency of certain structures. Specific requirements, advantages and limitations of use of the OCT technique in this area are discussed first. Then the overview of applications to easel paintings, historic glass, and craftsmanship is given, followed by two examples of monitoring the laser ablation with OCT: very local in case of Laser Induced Breakdown Spectroscopy (LIBS), and more general in case of laser ablation of the varnish layer. Then the examples of application of OCT to examination of paintings are given: investigation of deterioration of the varnish layer in the "Adoration of the Magi" by Leonardo da Vinci (Uffizi, Italy), imaging of overpaintings on two 17th and 18th c. oil paintings on canvas, and visualization of specific case of retouching located between two layers of varnish in the "Madonna with Yarnwinder" (attributed to L. da Vinci, private property).

  4. Wind-Induced Reconfigurations in Flexible Branched Trees

    NASA Astrophysics Data System (ADS)

    Ojo, Oluwafemi; Shoele, Kourosh

    2017-11-01

    Wind induced stresses are the major mechanical cause of failure in trees. We know that the branching mechanism has an important effect on the stress distribution and stability of a tree in the wind. Eloy in PRL 2011, showed that Leonardo da Vinci's original observation which states the total cross section of branches is conserved across branching nodes is the best configuration for resisting wind-induced fracture in rigid trees. However, prediction of the fracture risk and pattern of a tree is also a function of their reconfiguration capabilities and how they mitigate large wind-induced stresses. In this studies through developing an efficient numerical simulation of flexible branched trees, we explore the role of the tree flexibility on the optimal branching. Our results show that the probability of a tree breaking at any point depends on both the cross-section changes in the branching nodes and the level of tree flexibility. It is found that the branching mechanism based on Leonardo da Vinci's original observation leads to a uniform stress distribution over a wide range of flexibilities but the pattern changes for more flexible systems.

  5. Modeling and optimal design of an optical MEMS tactile sensor for use in robotically assisted surgery

    NASA Astrophysics Data System (ADS)

    Ahmadi, Roozbeh; Kalantari, Masoud; Packirisamy, Muthukumaran; Dargahi, Javad

    2010-06-01

    Currently, Minimally Invasive Surgery (MIS) performs through keyhole incisions using commercially available robotic surgery systems. One of the most famous examples of these robotic surgery systems is the da Vinci surgical system. In the current robotic surgery systems like the da Vinci, surgeons are faced with problems such as lack of tactile feedback during the surgery. Therefore, providing a real-time tactile feedback from interaction between surgical instruments and tissue can help the surgeons to perform MIS more reliably. The present paper proposes an optical tactile sensor to measure the contact force between the bio-tissue and the surgical instrument. A model is proposed for simulating the interaction between a flexible membrane and bio-tissue based on the finite element methods. The tissue is considered as a hyperelastic material with the material properties similar to the heart tissue. The flexible membrane is assumed as a thin layer of silicon which can be microfabricated using the technology of Micro Electro Mechanical Systems (MEMS). The simulation results are used to optimize the geometric design parameters of a proposed MEMS tactile sensor for use in robotic surgical systems to perform MIS.

  6. The mathematization of biology and medicine: who, when, how? [Retrospectroscope].

    PubMed

    Valentinuzzi, Max; Kohen, Alberto

    2013-01-01

    One objective of bioengineering is the quantification of the biological and medical sciences, with the goal of improving their exactness and preciseness, always in an attempt to remove as many indeterminations and uncertainties as possible, especially when seeking predictions. The extract at the beginning of the column, which is attributed to Leonardo da Vinci, seems to reflect a very early Renaissance concept in such a direction; this concept is indeed more general because it encompasses all the sciences [1]. The famous Vitruvian Man, so many times reproduced on book covers and posters, appears perhaps as an anticipatory geometrical epitome of that modern recent aim (Figure 1). However, 200 years before da Vinci was Ramon Llull (ca. 1232-1315), a Majorcan philosopher, member of the Third Order of Saint Francis, and author of important works of Catalan literature. Lull is considered by some to be a pioneer of computation theory because of his contributions to logics. Should he also be considered a very early predecessor of biomathematics? We leave this question dangling for the historian and/or the philosopher of history. In Spain, there is a journal carrying his name, Llull (see [12]).

  7. Virtual reality surgical simulators- a prerequisite for robotic surgery.

    PubMed

    Rajanbabu, Anupama; Drudi, Laura; Lau, Susie; Press, Joshua Z; Gotlieb, Walter H

    2014-06-01

    The field of computer assisted minimally invasive surgery is rapidly expanding worldwide, including in India. With more hospitals in India contemplating the acquisition of a robotic platform, training of robotic surgeons is becoming essential. Virtual reality simulators can be used for surgeons to become acquainted with the robotic console prior to live surgery. Our aim was to evaluate the amount of simulator training required before a surgeon first operates on the da Vinci® Surgical System. Simulations were conducted on the Intuitive Surgical's da Vinci® Robot Skill Simulator using the software obtained from Mimic Technologies. Participants included attending staff surgeons experienced in robotic surgery and novices. A set of seven activities were chosen for each participant. Based on the mean exercise score from the first attempt, staff surgeons outperformed the novices in all exercises. However, the difference in score between the staff and the novices decreased after the participants repeated the exercises and by the sixth attempt most of the novices obtained similar scores to the staff, suggesting that this might be at present the minimum set of repetitions indicated (or required) prior to performing life robotic surgery.

  8. Robotics Strategy White Paper

    DTIC Science & Technology

    2009-03-19

    Cargo packaging and pallet assembly. Use of robotics tools to support palletization falls under the supply functional area which tasks the Army to...system. 17 At first glance, remote tele-operated surgery capability appears to already exist in civilian hospitals (i.e., DaVinci Machine: http... tool free maintenance and anticipatory sustainment and improved distribution. The UJTL tasks suggest nominal improvements in the maintenance area

  9. Astronomy in the Age of Leonardo.

    NASA Astrophysics Data System (ADS)

    Welther, B. L.

    1997-12-01

    In the 1450s, when Leonardo da Vinci was born, horoscopes were still based primarily on the 13th-century tables developed in the court of Alfonso el Sabio of Spain. By the 15th century European astronomers were computing revised forms of the tables. In Italy, for example, Giovanni Bianchini of Ferrara completed his Tabulae astronomicae in the 1440s. It was finally published posthumously in Venice in 1495. By the 1480s Domenico Maria Novara, a professor of astronomy in Bologna, was publishing annual prognostications of eclipses, conjunctions, and other celestial phenomena. Against this background of traditional astronomy in Italy, two Florentines recorded observations of the sun and moon, comets, and meteorology. Paolo dal Pozzi Toscanelli flourished in the first half of the 15th century and Leonardo da Vinci in the last half. Their observations of celestial phenomena were not primarily for astronomical purposes; they were spinoffs of other pursuits such as medicine, astrology, optics, engineering, and studies of light and shadow. As a physician and cartographer, Toscanelli practiced astrology, studied omens, observed comets and plotted their paths on homemade maps. He also was associated with the construction of a gnomon at the top of the Duomo to observe the summer solstice. It was this project that may have brought him into contact with the young artisan, Leonardo da Vinci. As a painter, Leonardo's approach to science and engineering was to observe, sketch and analyze. His interest in light and shadow led him to notice how the earth, moon and planets all reflect sunlight. His extant manuscripts have geometric sketches for eclipses and for the phenomenon known as "old moon in new moon's arms." Unfortunately, because neither Toscanelli nor Leonardo published their observations, they made no impact on the history of astronomical thought or observation. Their contemporaries did not know or write about their work. Astronomers in the 16th century did not know about

  10. Combined Partial Penectomy With Bilateral Robotic Inguinal Lymphadenectomy Using Near-infrared Fluorescence Guidance.

    PubMed

    Sávio, Luís Felipe; Panizzutti Barboza, Marcelo; Alameddine, Mahmoud; Ahdoot, Michael; Alonzo, David; Ritch, Chad R

    2018-03-01

    To describe our novel technique for performing a combined partial penectomy and bilateral robotic inguinal lymphadenectomy using intraoperative near-infrared (NIR) fluorescence guidance with indocyanine green (ICG) and the DaVinci Firefly camera system. A 58-year-old man presented status post recent excisional biopsy of a 2-cm lesion on the left coronal aspect of the glans penis. Pathology revealed "invasive squamous cell carcinoma of the penis with multifocal positive margins." His examination was suspicious for cT2 primary and his inguinal nodes were cN0. He was counseled to undergo partial penectomy with possible combined vs staged bilateral robotic inguinal lymphadenectomy. Preoperative computed tomography scan was negative for pathologic lymphadenopathy. Before incision, 5 mL of ICG was injected subcutaneously beneath the tumor. Bilateral thigh pockets were then developed simultaneously and a right, then left robotic modified inguinal lymphadenectomy was performed using NIR fluorescence guidance via the DaVinci Firefly camera. A partial penectomy was then performed in the standard fashion. The combined procedure was performed successfully without complication. Total operative time was 379 minutes and total robotic console time was 95 minutes for the right and 58 minutes to the left. Estimated blood loss on the right and left were 15 and 25 mL, respectively. A total of 24 lymph nodes were retrieved. This video demonstrates a safe and feasible approach for combined partial penectomy and bilateral inguinal lymphadenectomy with NIR guidance using ICG and the DaVinci Firefly camera system. The combined robotic approach has minimal morbidity and avoids the need for a staged procedure. Furthermore, use of NIR guidance with ICG during robotic inguinal lymphadenectomy is feasible and may help identify sentinel lymph nodes and improve the quality of dissection. Further studies are needed to confirm the utility of NIR guidance for robotic sentinel lymph node

  11. Overcoming extreme obesity with robotic surgery.

    PubMed

    Stone, Pamela; Burnett, Alexander; Burton, Brian; Roman, Juan

    2010-12-01

    Obesity is often associated with endometrial cancer and has posed a challenge in surgical management. Complications such as wound breakdown, respiratory challenges, cardiac complications and difficult intubations are associated with obesity. For the patient with uterine cancer, surgery is necessary for staging, control of symptoms and cure. With the advent of the da Vinci(™) intuitive robot, alternative surgical options can now be offered to these patients. While surgery is the principal modality for the treatment and management of uterine cancer, the morbidly obese patient faces increased complications and longer postoperative recovery. As studied in the LAP2, comparable outcomes have been noted in laparotomy vs laparoscopic surgery. Recently, minimally invasive surgery has been refined with the advent of the da Vinci robotic system. Applying a minimally invasive technique further enhanced with the da Vinci robotic system, a total laparoscopic hysterectomy with bilateral salpingo-oophorectomy was performed on a patient with a BMI of 98. A 35 year-old G0 woman with a BMI of 98 presented with heavy vaginal bleeding and anaemia. She was diagnosed with endometrioid adenocarcinoma of the uterus, FIGO grade 1. She was treated with a robotically assisted total laparoscopic hysterectomy and bilateral salpingo-oophorectomy. Her postoperative course was uncomplicated and she was discharged home on post-operative day 1. Since obesity is a significant risk factor for endometrial cancer and the prevalence of obesity is increasing, developing surgical techniques to appropriately manage these patients is important. Minimally invasive surgery, specifically with robotic assistance, has increased the possibilities of performing minimally invasive surgery in morbidly obese women. It allows navigation around anatomical barriers and decreases the fatigue experienced by the surgeons. With the increasing obesity of our population and the high prevalence of uterine cancer, further

  12. Getting started with robotics in general surgery with cholecystectomy: the Canadian experience.

    PubMed

    Jayaraman, Shiva; Davies, Ward; Schlachta, Christopher M

    2009-10-01

    The value of robotics in general surgery may be for advanced minimally invasive procedures. Unlike other specialties, formal fellowship training opportunities for robotic general surgery are few. As a result, most surgeons currently develop robotic skills in practice. Our goal was to determine whether robotic cholecystectomy is a safe and effective bridge to advanced robotics in general surgery. Before performing advanced robotic procedures, 2 surgeons completed the Intuitive Surgical da Vinci training course and agreed to work together on all procedures. Clinical surgery began with da Vinci cholecystectomy with a plan to begin advanced procedures after at least 10 cholecystectomies. We performed a retrospective review of our pilot series of robotic cholecystectomies and compared them with contemporaneous laparoscopic controls. The primary outcome was safety, and the secondary outcome was learning curve. There were 16 procedures in the robotics arm and 20 in the laparoscopic arm. Two complications (da Vinci port-site hernia, transient elevation of liver enzymes) occurred in the robotic arm, whereas only 1 laparoscopic patient (slow to awaken from anesthetic) experienced a complication. None was significant. The mean time required to perform robotic cholecystectomy was significantly longer than laparoscopic surgery (91 v. 41 min, p < 0.001). The mean time to clear the operating room was significantly longer for robotic procedures (14 v. 11 min, p = 0.015). We observed a trend showing longer mean anesthesia time for robotic procedures (23 v. 15 min). Regarding learning curve, the mean operative time needed for the first 3 robotic procedures was longer than for the last 3 (101 v. 80 min); however, this difference was not significant. Since this experience, the team has confidently gone on to perform robotic biliary, pancreatic, gastresophageal, intestinal and colorectal operations. Robotic cholecystectomy can be performed reliably; however, owing to the significant

  13. Getting started with robotics in general surgery with cholecystectomy: the Canadian experience

    PubMed Central

    Jayaraman, Shiva; Davies, Ward; Schlachta, Christopher M.

    2009-01-01

    Background The value of robotics in general surgery may be for advanced minimally invasive procedures. Unlike other specialties, formal fellowship training opportunities for robotic general surgery are few. As a result, most surgeons currently develop robotic skills in practice. Our goal was to determine whether robotic cholecystectomy is a safe and effective bridge to advanced robotics in general surgery. Methods Before performing advanced robotic procedures, 2 surgeons completed the Intuitive Surgical da Vinci training course and agreed to work together on all procedures. Clinical surgery began with da Vinci cholecystectomy with a plan to begin advanced procedures after at least 10 cholecystectomies. We performed a retrospective review of our pilot series of robotic cholecystectomies and compared them with contemporaneous laparoscopic controls. The primary outcome was safety, and the secondary outcome was learning curve. Results There were 16 procedures in the robotics arm and 20 in the laparoscopic arm. Two complications (da Vinci port-site hernia, transient elevation of liver enzymes) occurred in the robotic arm, whereas only 1 laparoscopic patient (slow to awaken from anesthetic) experienced a complication. None was significant. The mean time required to perform robotic cholecystectomy was significantly longer than laparoscopic surgery (91 v. 41 min, p < 0.001). The mean time to clear the operating room was significantly longer for robotic procedures (14 v. 11 min, p = 0.015). We observed a trend showing longer mean anesthesia time for robotic procedures (23 v. 15 min). Regarding learning curve, the mean operative time needed for the first 3 robotic procedures was longer than for the last 3 (101 v. 80 min); however, this difference was not significant. Since this experience, the team has confidently gone on to perform robotic biliary, pancreatic, gastresophageal, intestinal and colorectal operations. Conclusion Robotic cholecystectomy can be performed reliably

  14. United States Human Access to Space, Exploration of the Moon and Preparation for Mars Exploration

    NASA Technical Reports Server (NTRS)

    Rhatigan, Jennifer L.

    2009-01-01

    In the past, men like Leonardo da Vinci and Jules Verne imagined the future and envisioned fantastic inventions such as winged flying machines, submarines, and parachutes, and posited human adventures like transoceanic flight and journeys to the Moon. Today, many of their ideas are reality and form the basis for our modern world. While individual visionaries like da Vinci and Verne are remembered for the accuracy of their predictions, today entire nations are involved in the process of envisioning and defining the future development of mankind, both on and beyond the Earth itself. Recently, Russian, European, and Chinese teams have all announced plans for developing their own next generation human space vehicles. The Chinese have announced their intention to conduct human lunar exploration, and have flown three crewed space missions since 2003, including a flight with three crew members to test their extravehicular (spacewalking) capabilities in September 2008. Very soon, the prestige, economic development, scientific discovery, and strategic security advantage historically associated with leadership in space exploration and exploitation may no longer be the undisputed province of the United States. Much like the sponsors of the seafaring explorers of da Vinci's age, we are motivated by the opportunity to obtain new knowledge and new resources for the growth and development of our own civilization. NASA's new Constellation Program, established in 2005, is tasked with maintaining the United States leadership in space, exploring the Moon, creating a sustained human lunar presence, and eventually extending human operations to Mars and beyond. Through 2008, the Constellation Program developed a full set of detailed program requirements and is now completing the preliminary design phase for the new Orion Crew Exploration Vehicle (CEV), the Ares I Crew Launch Vehicle, and the associated infrastructure necessary for humans to explore the Moon. Component testing is well

  15. A Fixed-Wing Aircraft Simulation Tool for Improving the efficiency of DoD Acquisition

    DTIC Science & Technology

    2015-10-05

    simulation tool , CREATETM-AV Helios [12-14], a high fidelity rotary wing vehicle simulation tool , and CREATETM-AV DaVinci [15-16], a conceptual through...05/2015 Oct 2008-Sep 2015 A Fixed-Wing Aircraft Simulation Tool for Improving the Efficiency of DoD Acquisition Scott A. Morton and David R...multi-disciplinary fixed-wing virtual aircraft simulation tool incorporating aerodynamics, structural dynamics, kinematics, and kinetics. Kestrel allows

  16. Technology Convergence and National Security

    DTIC Science & Technology

    2010-08-25

    transdisciplinary nature of that convergence that was critical. Sandro Botticelli Michelangelo Buonarroti Lorenzo the Magnificent Andrea del Verrocchio Leonardo ...da  Vinci   UNCLASSIFIED BACKGROUND LOGIC • Many traditional R&D programs have been commodity or  capability driven, and based on a perceived threat

  17. Leonardo Da Vinci, the genius and the monsters. Casual encounters?

    PubMed

    Ciseri, Lorenzo Montemagno

    2014-01-01

    This article analyses Leonardo's interest in monsters and deformed reality, one of the lesser known aspects of his vast and multifaceted output. With the possible exception of his studies of physiognomy, relevant drawings, sketches and short stories represent a marginal aspect of his work, but they are nevertheless significant for historians of teratology. The purpose of this study is to provide a broad overview of the relationship between Leonardo and both the literature on mythological monsters and the reports on monstrous births that he either read about or witnessed personally. While aspects of his appreciation and attention to beauty and the pursuit of perfection and good proportions are the elements most emphasised in Leonardo's work, other no less interesting aspects related to deformity have been considered of marginal importance. My analysis will demonstrate that Leonardo approached the realm of monstrosity as if he considered abnormality a mirror of normality, deformity a mirror of harmony, and disease a mirror of health, as if to emphasise that, ultimately, it is the monster that gives the world the gift of normality. Two special cases of monstrosity are analysed: the famous monster of Ravenna, whose image was found among his papers, and a very rare case of parasitic conjoined twins (thoracopagus parasiticus) portrayed for the first time alive, probably in Florence, by Leonardo himself.

  18. Scientific Aspects of Leonardo da Vinci's Drawings: An Interdisciplinary Model.

    ERIC Educational Resources Information Center

    Struthers, Sally A.

    While interdisciplinary courses can help demonstrate the relevance of learning to students and reinforce education from different fields, they can be difficult to implement and are often not cost effective. An interdisciplinary art history course at Ohio's Sinclair Community College incorporates science into the art history curriculum, making use…

  19. Urologic robots and future directions.

    PubMed

    Mozer, Pierre; Troccaz, Jocelyne; Stoianovici, Dan

    2009-01-01

    Robot-assisted laparoscopic surgery in urology has gained immense popularity with the daVinci system, but a lot of research teams are working on new robots. The purpose of this study is to review current urologic robots and present future development directions. Future systems are expected to advance in two directions: improvements of remote manipulation robots and developments of image-guided robots. The final goal of robots is to allow safer and more homogeneous outcomes with less variability of surgeon performance, as well as new tools to perform tasks on the basis of medical transcutaneous imaging, in a less invasive way, at lower costs. It is expected that improvements for a remote system could be augmented in reality, with haptic feedback, size reduction, and development of new tools for natural orifice translumenal endoscopic surgery. The paradigm of image-guided robots is close to clinical availability and the most advanced robots are presented with end-user technical assessments. It is also notable that the potential of robots lies much further ahead than the accomplishments of the daVinci system. The integration of imaging with robotics holds a substantial promise, because this can accomplish tasks otherwise impossible. Image-guided robots have the potential to offer a paradigm shift.

  20. UROLOGIC ROBOTS AND FUTURE DIRECTIONS

    PubMed Central

    Mozer, Pierre; Troccaz, Jocelyne; Stoianovici, Dan

    2009-01-01

    Purpose of review Robot-assisted laparoscopic surgery in urology has gained immense popularity with the Da Vinci system but a lot of research teams are working on new robots. The purpose of this paper is to review current urologic robots and present future developments directions. Recent findings Future systems are expected to advance in two directions: improvements of remote manipulation robots and developments of image-guided robots. Summary The final goal of robots is to allow safer and more homogeneous outcomes with less variability of surgeon performance, as well as new tools to perform tasks based on medical transcutaneous imaging, in a less invasive way, at lower costs. It is expected that improvements for remote system could be augmented reality, haptic feed back, size reduction and development of new tools for NOTES surgery. The paradigm of image-guided robots is close to a clinical availability and the most advanced robots are presented with end-user technical assessments. It is also notable that the potential of robots lies much further ahead than the accomplishments of the daVinci system. The integration of imaging with robotics holds a substantial promise, because this can accomplish tasks otherwise impossible. Image guided robots have the potential to offer a paradigm shift. PMID:19057227

  1. Rise characteristics of gas bubbles in a 2D rectangular column: VOF simulations vs experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishna, R.; Baten, J.M. van

    About five centuries ago, Leonardo da Vinci described the sinuous motion of gas bubbles rising in water. The authors have attempted to simulate the rise trajectories of bubbles of 4, 5, 7, 8, 9, 12, and 20 mm in diameter rising in a 2D rectangular column filled with water. The simulations were carried out using the volume-of-fluid (VOF) technique developed by Hirt and Nichols (J. Computational Physics, 39, 201--225 (1981)). To solve the Navier-Stokes equations of motion the authors used a commercial solver, CFX 4.1c of AEA Technology, UK. They developed their own bubble-tracking algorithm to capture sinuous bubble motions.more » The 4 and 5 mm bubbles show large lateral motions observed by Da Vinci. The 7, 8 and 9 mm bubble behave like jellyfish. The 12 mm bubble flaps its wings like a bird. The extent of lateral motion of the bubbles decreases with increasing bubble size. Bubbles larger than 20 mm in size assume a spherical cap form and simulations of the rise characteristics match experiments exactly. VOF simulations are powerful tools for a priori determination of the morphology and rise characteristics of bubbles rising in a liquid. Bubble-bubble interactions are also properly modeled by the VOF technique.« less

  2. The Dark Focus of Visual Accommodation: Its Existence, Its Measurement, Its Effects

    DTIC Science & Technology

    1979-11-01

    DaVinci Jepicted the lens as a light focusing agent, but went virtually unnoticed as there was no available means to mass-produce his drawings (see...the Bates method of treating myopia in wni2n suggestion and relaxation techniques apparently yielded improved acuity. Working with hypnosis ,. he found...1’ Acute myopes had the greatest improvement during hypnosis . 2) Out ’f 1 49 nypnosis, acuity improvement transferred, but no refractive changes

  3. Reconstruction, Enhancement, Visualization, and Ergonomic Assessment for Laparoscopic Surgery

    DTIC Science & Technology

    2007-02-01

    support and upgrade of the REVEAL display system and tool suite in the University of Maryland Medical Center’s Simulation Center, (2) stereo video display...technology deployment, (3) stereo probe calibration benchmarks and support tools , (4) the production of research media, (5) baseline results from...endoscope can be used to generate a stereoscopic view for a surgeon, as with the DaVinci robot in use today. In order to use such an endoscope for

  4. Resistance to Organizational Cultural Change in the Military -- A JFO Case Study

    DTIC Science & Technology

    2008-04-02

    is seen by all members as supporting their interests.38 There are many tools to assist in formulating climate or culture change and one such tool ...an important change formulation tool , stood up a training center with excellent support and expert trainers from both services, and set a high...Endnotes 1 R. Dale Jeffery, The Soldier’s Quote Book (Houston, TX: DaVinci Publishing Group, 2000), 119. 2 Robert M. Murphy, Managing Strategic Change

  5. New stapling devices in robotic surgery

    PubMed Central

    Casiraghi, Monica; Pardolesi, Alessandro; Borri, Alessandro; Spaggiari, Lorenzo

    2017-01-01

    Minimally invasive thoracic surgery is rapidly diffusing worldwide. Robotic anatomic pulmonary resection is gaining popularity and acceptance in the thoracic community for the reported feasibility, safety, and good outcomes. The last available robotic system, da Vinci Xi System, added new technical improvements on robotic device allowing best performances in robotic lung resection. We report our initial experience in the use of EndoWrist Stapler during robotic anatomic surgery for lung cancer. PMID:29078608

  6. [Robot-assisted liver resection].

    PubMed

    Aselmann, H; Möller, T; Kersebaum, J-N; Egberts, J H; Croner, R; Brunner, M; Grützmann, R; Becker, T

    2017-06-01

    Robotic liver resection can overcome some of the limitations of laparoscopic liver surgery; therefore, it is a promising tool to increase the proportion of minimally invasive liver resections. The present article gives an overview of the current literature. Furthermore, the results of a nationwide survey on robotic liver surgery among hospitals in Germany with a DaVinci system used in general visceral surgery and the perioperative results of two German robotic centers are presented.

  7. REVEAL: Reconstruction, Enhancement, Visualization, and Ergonomic Assessment for Laparoscopy

    DTIC Science & Technology

    2008-08-01

    measurable disparity shift. Such an endoscope can be used to generate a stereoscopic view for a surgeon, as with the DaVinci robot in use today...training or surgery. We are working on the user interface issues of incorporating this measurement capability into the standard set of tools during...scope use, and in structuring a set of tasks around the use of through-the-scope measurement in order to determine how this tool can affect efficiency

  8. Technological Innovation: Roles and Implications in Army Aviations Special Operations

    DTIC Science & Technology

    2008-12-01

    factor in winning a war comes down to the individual soldier, not having the correct tools and equipment to efficiently complete the mission can...years later by the Army’s Signal Corps. The balloon was used as an effective tool for not only conducting aerial observation but also in...known air platform was also being developed, the helicopter. The concept of the helicopter has roots that go as far back as DaVinci with his drawings

  9. Application of Powered High Lift Systems to STOL Aircraft Design.

    DTIC Science & Technology

    1979-09-01

    century by da Vinci, an English - man named Sir George Cayley first attempted to integrate the features of the helicopter and the airplane. In 1843 his...horizontal flight Jun 1959 WEIGHT: 6500 LBS ENGINES: (1) SNECMA ATAR 101 E.V. Turbojet of 8155 lbs thrust LAYOUT: See Fig. 21 COMMENTS: SNECMA was engaged...34 ATAR VOLANT" test vehicle fitted with an annular wing to permit transition to horizontal flight. The aircraft was controlled from a tilting ejec- tion

  10. Application of robotics in general surgery: initial experience.

    PubMed

    Nguyen, Ninh T; Hinojosa, Marcelo W; Finley, David; Stevens, Melinda; Paya, Mahbod

    2004-10-01

    Robotic surgery was recently approved for clinical use in general abdominal surgery. The aim of this study was to review our experience with the da Vinci surgical system during laparoscopic general surgical procedures. Eighteen patients underwent robotically assisted laparoscopic abdominal surgery between June 2002 and March 2003. Main outcome measures were operative time, room setup time, robotic arm-positioning and surgical time, blood loss, conversion to laparoscopy, length of stay, and morbidity. The types of robotically assisted laparoscopic procedures were excision of gastric leiomyoma (n = 1), Heller myotomy (n = 1), cholecystectomy (n = 2), gastric banding (n = 2), Nissen fundoplication (n = 4), and gastric bypass (n = 8). The mean room setup time was 63 +/- 14 minutes, and the mean robotic arm-positioning time was 16 +/- 7 minutes. Conversion to laparoscopy occurred in two (11%) of 18 cases because of equipment difficulty (n = 1) and technical difficulty (n = 1). Estimated blood loss was 91 +/- 71 mL. The mean operative time was 156 +/- 42 minutes, and the robotic operative time was 27% of the total operative time. The mean length of hospital stay was 2.2 +/- 1.5 days. There was one postoperative wound infection and one anastomotic stricture. Robotically assisted laparoscopic abdominal surgery is feasible and safe; however, the theoretical advantages of the da Vinci surgical system were not clinically apparent.

  11. Single port radical prostatectomy: current status.

    PubMed

    Martín, Oscar Darío; Azhar, Raed A; Clavijo, Rafael; Gidelman, Camilo; Medina, Luis; Troche, Nelson Ramirez; Brunacci, Leonardo; Sotelo, René

    2016-06-01

    The aim of this study is to analyze the current literature on single port radical prostatectomy (LESS-RP). Single port radical prostatectomy laparoendoscopic (LESS-RP) has established itself as a challenge for urological community, starting with the proposal of different approaches: extraperitoneal, transperitoneal and transvesical, initially described for laparoscopy and then laparoscopy robot-assisted. In order to improve the LESS-RP, new instruments, optical devices, trocars and retraction mechanisms have been developed. Advantages and disadvantages of LESS-RP are controversial, while some claim that it is a non-trustable approach, regarding the low cases number and technical difficulties, others acclaim that despite this facts some advantages have been shown and that previous described difficulties are being overcome, proving this is novel proposal of robotics platform, the Da Vinci SP, integrating the system into "Y". The LESS-RP approach gives us a new horizon and opens the door for rapid standardization of this technique. The few studies and short series available can be result of a low interest in the application of LESS-RP in prostate, probably because of the technical complexity that it requires. The new robotic platform, the da Vinci SP, shows that it is clear that the long awaited evolution of robotic technologies for laparoscopy has begun, and we must not lose this momentum.

  12. Robotic general surgery: current practice, evidence, and perspective.

    PubMed

    Jung, M; Morel, P; Buehler, L; Buchs, N C; Hagen, M E

    2015-04-01

    Robotic technology commenced to be adopted for the field of general surgery in the 1990s. Since then, the da Vinci surgical system (Intuitive Surgical Inc, Sunnyvale, CA, USA) has remained by far the most commonly used system in this domain. The da Vinci surgical system is a master-slave machine that offers three-dimensional vision, articulated instruments with seven degrees of freedom, and additional software features such as motion scaling and tremor filtration. The specific design allows hand-eye alignment with intuitive control of the minimally invasive instruments. As such, robotic surgery appears technologically superior when compared with laparoscopy by overcoming some of the technical limitations that are imposed on the surgeon by the conventional approach. This article reviews the current literature and the perspective of robotic general surgery. While robotics has been applied to a wide range of general surgery procedures, its precise role in this field remains a subject of further research. Until now, only limited clinical evidence that could establish the use of robotics as the gold standard for procedures of general surgery has been created. While surgical robotics is still in its infancy with multiple novel systems currently under development and clinical trials in progress, the opportunities for this technology appear endless, and robotics should have a lasting impact to the field of general surgery.

  13. Soft Robotic Manipulator for Improving Dexterity in Minimally Invasive Surgery.

    PubMed

    Diodato, Alessandro; Brancadoro, Margherita; De Rossi, Giacomo; Abidi, Haider; Dall'Alba, Diego; Muradore, Riccardo; Ciuti, Gastone; Fiorini, Paolo; Menciassi, Arianna; Cianchetti, Matteo

    2018-02-01

    Combining the strengths of surgical robotics and minimally invasive surgery (MIS) holds the potential to revolutionize surgical interventions. The MIS advantages for the patients are obvious, but the use of instrumentation suitable for MIS often translates in limiting the surgeon capabilities (eg, reduction of dexterity and maneuverability and demanding navigation around organs). To overcome these shortcomings, the application of soft robotics technologies and approaches can be beneficial. The use of devices based on soft materials is already demonstrating several advantages in all the exploitation areas where dexterity and safe interaction are needed. In this article, the authors demonstrate that soft robotics can be synergistically used with traditional rigid tools to improve the robotic system capabilities and without affecting the usability of the robotic platform. A bioinspired soft manipulator equipped with a miniaturized camera has been integrated with the Endoscopic Camera Manipulator arm of the da Vinci Research Kit both from hardware and software viewpoints. Usability of the integrated system has been evaluated with nonexpert users through a standard protocol to highlight difficulties in controlling the soft manipulator. This is the first time that an endoscopic tool based on soft materials has been integrated into a surgical robot. The soft endoscopic camera can be easily operated through the da Vinci Research Kit master console, thus increasing the workspace and the dexterity, and without limiting intuitive and friendly use.

  14. Use of a mobile tower-based robot--The initial Xi robot experience in surgical oncology.

    PubMed

    Yuh, Bertram; Yu, Xian; Raytis, John; Lew, Michael; Fong, Yuman; Lau, Clayton

    2016-01-01

    The da Vinci Xi platform provides expanded movement of the arms relative to the base, theoretically allowing increased versatility in complex multi-field or multi-quadrant surgery. We describe the initial Xi experience in oncologic surgery at a tertiary cancer center. One hundred thirty unique robot-assisted procedures were performed using the Xi between 2014 and 2015, 112 of which were oncology surgeries. For procedures involving multiple quadrants, the robot was re-targeted. Complications were assessed according to Martin criteria and the Clavien-Dindo classification up to 90 days after operation. Thirteen different operations were performed in five oncology subspecialties (urology, gynecology, thoracic, hepatobiliary, and gastrointestinal surgery). Median operative times ranged from 183 min for nephroureterectomy to 543 min for esophagogastrectomy. Median estimated blood loss did not exceed 200 ml for any of the categorized procedures . No patients were transfused intraoperatively and no positioning injuries occurred. Conversions to open operation occurred in three cases (2.7%), though not related to complications or technical considerations. Overall complication rate was 26% with major complication rate of 4%. Readmissions were necessary in 11 (10%) patients. The da Vinci Xi can be safely assimilated into a surgical oncology program. The Xi offers versatility to various oncologic procedures with satisfactory complication and readmission rates. © 2015 Wiley Periodicals, Inc.

  15. Da Vincis Children Take Flight: Unmanned Aircraft Systems in the Homeland

    DTIC Science & Technology

    2014-03-01

    corporate self-regulation, consistent with a laissez - faire tradition. B. TOWARD A POLICY OPTION TO PROTECT PRIVACY WHILE MAINTAINING TRANSPARENCY Over...take this journey and shared many a conversation over 4 a.m. coffee; who has borne more than his fair share of the responsibility for our home; and...alternate routes to meet consumer demand.  Public interest is considered, as expressed through political leadership . Public interest will be assumed to

  16. Evolution of the paranasal sinuses' anatomy through the ages

    PubMed Central

    Mavrodi, Alexandra

    2013-01-01

    Previously, anatomists considered paranasal sinuses as a mysterious region of the human skull. Historically, paranasal sinuses were first identified by ancient Egyptians and later, by Greek physicians. After a long period of no remarkable improvement in the understanding of anatomy during the Middle Ages, anatomists of the Renaissance period-Leonardo da Vinci and Vesalius-made their own contribution. Nathaniel Highmore's name is also associated with the anatomy of paranasal sinuses as he was first to describe the maxillary sinus. PMID:24386595

  17. Limb replantation with two robots: a feasibility study in a pig model.

    PubMed

    Taleb, Chihab; Nectoux, Eric; Liverneaux, Philippe

    2009-01-01

    The aim of this study is to assess the feasibility of limb replantations and transplantations by telesurgery. The material consisted in a large white pig and two surgical robots (DaVinciS telemanipulators). The procedure consisted in a trans-humeral cross-section of the left thoracic limb, which was secondarily replanted. Results showed good vascular permeability, while the operator's physiological tremor was suppressed. Our results seem to demonstrate that telesurgery could improve limb replantation and transplantation management, especially regarding operating gesture precision. (c) 2009 Wiley-Liss, Inc.

  18. Caravaggio four centuries later: psychoanalytic portraits of ambivalence and ambiguity.

    PubMed

    Szajnberg, Nathan M

    2013-04-01

    Rome celebrated the four hundredth anniversary of Michelangelo Marisi da Caravaggio's death with an historical exhibition of his brief lifetime's work. Yet psychoanalysis has not studied this work extensively, despite the artist's compelling portrayal of a full range of human affects, including ambivalence. Psychoanalysis has studied artistic pioneers such as da Vinci (Freud 1910) and Michelangelo (Freud 1914), Giotto's use of blue sky as psychologically innovative (Blatt 1994), and Magritte's play with external reality (Spitz 1994). What can we learn about Caravaggio's work-including innovative contributions such as visual representation of expressed emotions, particularly negative emotions, including ambivalence, and remarkably candid, even critical, self-representations-and how can this late-sixteenth-century artist teach us about the development of the concept of mind underlying psychoanalysis?

  19. Global robotic experience and the type of surgical system impact the types of robotic malfunctions and their clinical consequences: an FDA MAUDE review.

    PubMed

    Lucas, Steven M; Pattison, Erik A; Sundaram, Chandru P

    2012-04-01

    To assess annual rates of robotic system malfunctions and compare the da Vinci S(®) system (dVS) and da Vinci(®) surgical system (dV). To assess the types of malfunctions and associated outcomes for robotic cases and determine the extent to which experience and technological improvements impact these. This study is a retrospective review of the US Food and Drug Administration (FDA) MAUDE (Manufacturer and User Facility Device Experience) database, a publicly available, voluntary reporting system (http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmaude/search.cfm). The database was searched using the two phrases 'da Vinci' and 'Intuitive Surgical' from 2003 to 2009. Malfunctions of the instruments, console, patient-side cart, camera and cannula were recorded. Data on intraoperative injuries, case delays and conversions were also collected. In all, 1914 reports were reviewed (991 dVS and 878 dV, 45 unclassified) with peak years for reports of 2008 for dVS (571) and 2007 for dV (211), P < 0.001. With respect to time, the proportion of console and patient-side cart malfunctions declined from 2007 onward compared with the proportions prior to 2007 (5.1% vs 9.4% and 6.6% vs 10.9%). Patient injury did not change with year of surgery (0.5-5.4% of malfunctions, P= 0.358), open conversions declined (21.3% of malfunctions before 2007 vs 9.9% from 2007 onward, P < 0.001) and patient deaths increased (0.0013% of cases before 2007 vs 0.0061% of cases from 2007 onward, P < 0.001). With regard to robotic system, console and patient-side cart malfunctions were more frequent with the dV than the dVS: 82/878 vs 39/991 and 100/878 vs 48/991, P < 0.001. Open conversion was more frequent with dV than dVS (19.3% vs 7.7% of reported malfunctions, P < 0.001), while patient injury was less with dV than dVS (3.5% vs 5.9%, P= 0.021). The dVS decreased console and patient-side cart errors relative to total malfunctions, which were also influenced by surgical year. Open conversions were

  20. Augmented reality image guidance for minimally invasive coronary artery bypass

    NASA Astrophysics Data System (ADS)

    Figl, Michael; Rueckert, Daniel; Hawkes, David; Casula, Roberto; Hu, Mingxing; Pedro, Ose; Zhang, Dong Ping; Penney, Graeme; Bello, Fernando; Edwards, Philip

    2008-03-01

    We propose a novel system for image guidance in totally endoscopic coronary artery bypass (TECAB). A key requirement is the availability of 2D-3D registration techniques that can deal with non-rigid motion and deformation. Image guidance for TECAB is mainly required before the mechanical stabilization of the heart, thus the most dominant source of non-rigid deformation is the motion of the beating heart. To augment the images in the endoscope of the da Vinci robot, we have to find the transformation from the coordinate system of the preoperative imaging modality to the system of the endoscopic cameras. In a first step we build a 4D motion model of the beating heart. Intraoperatively we can use the ECG or video processing to determine the phase of the cardiac cycle. We can then take the heart surface from the motion model and register it to the stereo-endoscopic images of the da Vinci robot using 2D-3D registration methods. We are investigating robust feature tracking and intensity-based methods for this purpose. Images of the vessels available in the preoperative coordinate system can then be transformed to the camera system and projected into the calibrated endoscope view using two video mixers with chroma keying. It is hoped that the augmented view can improve the efficiency of TECAB surgery and reduce the conversion rate to more conventional procedures.

  1. Development of a precision multimodal surgical navigation system for lung robotic segmentectomy.

    PubMed

    Baste, Jean Marc; Soldea, Valentin; Lachkar, Samy; Rinieri, Philippe; Sarsam, Mathieu; Bottet, Benjamin; Peillon, Christophe

    2018-04-01

    Minimally invasive sublobar anatomical resection is becoming more and more popular to manage early lung lesions. Robotic-assisted thoracic surgery (RATS) is unique in comparison with other minimally invasive techniques. Indeed, RATS is able to better integrate multiple streams of information including advanced imaging techniques, in an immersive experience at the level of the robotic console. Our aim was to describe three-dimensional (3D) imaging throughout the surgical procedure from preoperative planning to intraoperative assistance and complementary investigations such as radial endobronchial ultrasound (R-EBUS) and virtual bronchoscopy for pleural dye marking. All cases were operated using the DaVinci System TM . Modelisation was provided by Visible Patient™ (Strasbourg, France). Image integration in the operative field was achieved using the Tile Pro multi display input of the DaVinci console. Our experience was based on 114 robotic segmentectomies performed between January 2012 and October 2017. The clinical value of 3D imaging integration was evaluated in 2014 in a pilot study. Progressively, we have reached the conclusion that the use of such an anatomic model improves the safety and reliability of procedures. The multimodal system including 3D imaging has been used in more than 40 patients so far and demonstrated a perfect operative anatomic accuracy. Currently, we are developing an original virtual reality experience by exploring 3D imaging models at the robotic console level. The act of operating is being transformed and the surgeon now oversees a complex system that improves decision making.

  2. Three-dimensional vision enhances task performance independently of the surgical method.

    PubMed

    Wagner, O J; Hagen, M; Kurmann, A; Horgan, S; Candinas, D; Vorburger, S A

    2012-10-01

    Within the next few years, the medical industry will launch increasingly affordable three-dimensional (3D) vision systems for the operating room (OR). This study aimed to evaluate the effect of two-dimensional (2D) and 3D visualization on surgical skills and task performance. In this study, 34 individuals with varying laparoscopic experience (18 inexperienced individuals) performed three tasks to test spatial relationships, grasping and positioning, dexterity, precision, and hand-eye and hand-hand coordination. Each task was performed in 3D using binocular vision for open performance, the Viking 3Di Vision System for laparoscopic performance, and the DaVinci robotic system. The same tasks were repeated in 2D using an eye patch for monocular vision, conventional laparoscopy, and the DaVinci robotic system. Loss of 3D vision significantly increased the perceived difficulty of a task and the time required to perform it, independently of the approach (P < 0.0001-0.02). Simple tasks took 25 % to 30 % longer to complete and more complex tasks took 75 % longer with 2D than with 3D vision. Only the difficult task was performed faster with the robot than with laparoscopy (P = 0.005). In every case, 3D robotic performance was superior to conventional laparoscopy (2D) (P < 0.001-0.015). The more complex the task, the more 3D vision accelerates task completion compared with 2D vision. The gain in task performance is independent of the surgical method.

  3. Improved depth perception with three-dimensional auxiliary display and computer generated three-dimensional panoramic overviews in robot-assisted laparoscopy

    PubMed Central

    Wieringa, Fokko P.; Bouma, Henri; Eendebak, Pieter T.; van Basten, Jean-Paul A.; Beerlage, Harrie P.; Smits, Geert A. H. J.; Bos, Jelte E.

    2014-01-01

    Abstract. In comparison to open surgery, endoscopic surgery offers impaired depth perception and narrower field-of-view. To improve depth perception, the Da Vinci robot offers three-dimensional (3-D) video on the console for the surgeon but not for assistants, although both must collaborate. We improved the shared perception of the whole surgical team by connecting live 3-D monitors to all three available Da Vinci generations, probed user experience after two years by questionnaire, and compared time measurements of a predefined complex interaction task performed with a 3-D monitor versus two-dimensional. Additionally, we investigated whether the complex mental task of reconstructing a 3-D overview from an endoscopic video can be performed by a computer and shared among users. During the study, 925 robot-assisted laparoscopic procedures were performed in three hospitals, including prostatectomies, cystectomies, and nephrectomies. Thirty-one users participated in our questionnaire. Eighty-four percent preferred 3-D monitors and 100% reported spatial-perception improvement. All participating urologists indicated quicker performance of tasks requiring delicate collaboration (e.g., clip placement) when assistants used 3-D monitors. Eighteen users participated in a timing experiment during a delicate cooperation task in vitro. Teamwork was significantly (40%) faster with the 3-D monitor. Computer-generated 3-D reconstructions from recordings offered very wide interactive panoramas with educational value, although the present embodiment is vulnerable to movement artifacts. PMID:26158026

  4. Novel application of simultaneous multi-image display during complex robotic abdominal procedures

    PubMed Central

    2014-01-01

    Background The surgical robot offers the potential to integrate multiple views into the surgical console screen, and for the assistant’s monitors to provide real-time views of both fields of operation. This function has the potential to increase patient safety and surgical efficiency during an operation. Herein, we present a novel application of the multi-image display system for simultaneous visualization of endoscopic views during various complex robotic gastrointestinal operations. All operations were performed using the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) with the assistance of Tilepro, multi-input display software, during employment of the intraoperative scopes. Three robotic operations, left hepatectomy with intraoperative common bile duct exploration, low anterior resection, and radical distal subtotal gastrectomy with intracorporeal gastrojejunostomy, were performed by three different surgeons at a tertiary academic medical center. Results The three complex robotic abdominal operations were successfully completed without difficulty or intraoperative complications. The use of the Tilepro to simultaneously visualize the images from the colonoscope, gastroscope, and choledochoscope made it possible to perform additional intraoperative endoscopic procedures without extra monitors or interference with the operations. Conclusion We present a novel use of the multi-input display program on the da Vinci Surgical System to facilitate the performance of intraoperative endoscopies during complex robotic operations. Our study offers another potentially beneficial application of the robotic surgery platform toward integration and simplification of combining additional procedures with complex minimally invasive operations. PMID:24628761

  5. Using Contact Forces and Robot Arm Accelerations to Automatically Rate Surgeon Skill at Peg Transfer.

    PubMed

    Brown, Jeremy D; O Brien, Conor E; Leung, Sarah C; Dumon, Kristoffel R; Lee, David I; Kuchenbecker, Katherine J

    2017-09-01

    Most trainees begin learning robotic minimally invasive surgery by performing inanimate practice tasks with clinical robots such as the Intuitive Surgical da Vinci. Expert surgeons are commonly asked to evaluate these performances using standardized five-point rating scales, but doing such ratings is time consuming, tedious, and somewhat subjective. This paper presents an automatic skill evaluation system that analyzes only the contact force with the task materials, the broad-bandwidth accelerations of the robotic instruments and camera, and the task completion time. We recruited N = 38 participants of varying skill in robotic surgery to perform three trials of peg transfer with a da Vinci Standard robot instrumented with our Smart Task Board. After calibration, three individuals rated these trials on five domains of the Global Evaluative Assessment of Robotic Skill (GEARS) structured assessment tool, providing ground-truth labels for regression and classification machine learning algorithms that predict GEARS scores based on the recorded force, acceleration, and time signals. Both machine learning approaches produced scores on the reserved testing sets that were in good to excellent agreement with the human raters, even when the force information was not considered. Furthermore, regression predicted GEARS scores more accurately and efficiently than classification. A surgeon's skill at robotic peg transfer can be reliably rated via regression using features gathered from force, acceleration, and time sensors external to the robot. We expect improved trainee learning as a result of providing these automatic skill ratings during inanimate task practice on a surgical robot.

  6. From dV-Trainer to Real Robotic Console: The Limitations of Robotic Skill Training.

    PubMed

    Yang, Kun; Zhen, Hang; Hubert, Nicolas; Perez, Manuela; Wang, Xing Huan; Hubert, Jacques

    To investigate operators' performance quality, mental stress, and ergonomic habits through a training curriculum on robotic simulators. Forty volunteers without robotic surgery experience were recruited to practice 2 exercises on a dV-Trainer (dVT) for 14 hours. The simulator software (M-score a ) provided an automatic evaluation of the overall score for the surgeons' performance. Each participant provided a subjective difficulty score (validity to be proven) for each exercise. Their ergonomic habits were evaluated based on the workspace range and armrest load-validated criteria for evaluating the proficiency of using the armrest. They then repeated the same tasks on a da Vinci Surgical Skill Simulator for a final-level test. Their final scores were compared with their initial scores and the scores of 5 experts on the da Vinci Surgical Skill Simulator. A total of 14 hours of training on the dVT significantly improved the surgeons' performance scores to the expert level with a significantly reduced workload, but their ergonomic score was still far from the expert level. Sufficient training on the dVT improves novices' performance, reduces psychological stress, and inculcates better ergonomic habits. Among the evaluated criteria, novices had the most difficulty in achieving expert levels of ergonomic skills. The training benefits of robotic surgery simulators should be determined with quantified variables. The detection of the limitations during robotic training curricula could guide the targeted training and improve the training effect. Copyright © 2017. Published by Elsevier Inc.

  7. Artificial intelligence in medicine.

    PubMed

    Hamet, Pavel; Tremblay, Johanne

    2017-04-01

    Artificial Intelligence (AI) is a general term that implies the use of a computer to model intelligent behavior with minimal human intervention. AI is generally accepted as having started with the invention of robots. The term derives from the Czech word robota, meaning biosynthetic machines used as forced labor. In this field, Leonardo Da Vinci's lasting heritage is today's burgeoning use of robotic-assisted surgery, named after him, for complex urologic and gynecologic procedures. Da Vinci's sketchbooks of robots helped set the stage for this innovation. AI, described as the science and engineering of making intelligent machines, was officially born in 1956. The term is applicable to a broad range of items in medicine such as robotics, medical diagnosis, medical statistics, and human biology-up to and including today's "omics". AI in medicine, which is the focus of this review, has two main branches: virtual and physical. The virtual branch includes informatics approaches from deep learning information management to control of health management systems, including electronic health records, and active guidance of physicians in their treatment decisions. The physical branch is best represented by robots used to assist the elderly patient or the attending surgeon. Also embodied in this branch are targeted nanorobots, a unique new drug delivery system. The societal and ethical complexities of these applications require further reflection, proof of their medical utility, economic value, and development of interdisciplinary strategies for their wider application. Copyright © 2017. Published by Elsevier Inc.

  8. A System for Natural Language Sentence Generation.

    ERIC Educational Resources Information Center

    Levison, Michael; Lessard, Gregory

    1992-01-01

    Describes the natural language computer program, "Vinci." Explains that using an attribute grammar formalism, Vinci can simulate components of several current linguistic theories. Considers the design of the system and its applications in linguistic modelling and second language acquisition research. Notes Vinci's uses in linguistics…

  9. A portable X-ray diffraction apparatus for in situ analyses of masters' paintings

    NASA Astrophysics Data System (ADS)

    Eveno, Myriam; Duran, Adrian; Castaing, Jacques

    2010-09-01

    It is rare that the analyses of materials in paintings can be carried out by taking micro-samples. Valuable works of art are best studied in situ by non-invasive techniques. For that purpose, a portable X-ray diffraction and fluorescence apparatus has been designed and constructed at the C2RMF. This apparatus has been used for paintings of Rembrandt, Leonardo da Vinci, Van Gogh, Mantegna, etc. Results are given to illustrate the performance of X-ray diffraction, especially when X-ray fluorescence does not bring sufficient information to conclude.

  10. Being there: The continuing need for human presence in the deep ocean for scientific research and discovery

    NASA Astrophysics Data System (ADS)

    Fryer, P.; Fornari, D.; Perfit, M.; Von Damm, K.; Humphris, S.; Fox, P. J.; Lippsett, L.

    We see with our mind's eye. This poetic phrase attempts to describe a complex set of human interactions by which we take in and process information about the physical world around us. For millennia, scientists and philosophers have relied on our ability to apply the uniquely human traits of perception, cognition, memory and motor action to scientific observations and experiments. "There is no authority higher than the human eye," observed Leonardo Da Vinci, and his statement still holds true; as most field scientists will attest, there is no substitute for direct observation.

  11. Bubbles

    NASA Astrophysics Data System (ADS)

    Prosperetti, Andrea

    2004-06-01

    Vanitas vanitatum et omnia vanitas: bubbles are emptiness, non-liquid, a tiny cloud shielding a mathematical singularity. Born from chance, a violent and brief life ending in the union with the (nearly) infinite. But a wealth of phenomena spring forth from this nothingness: underwater noise, sonoluminescence, boiling, and many others. Some recent results on a "blinking bubble" micropump and vapor bubbles in sound fields are outlined. The last section describes Leonardo da Vinci's observation of the non-rectlinear ascent of buoyant bubbles and justifies the name Leonardo's paradox recently attributed to this phenomenon.

  12. Technological innovations in surgical approach for thyroid cancer.

    PubMed

    Lang, Brian Hung-Hin; Lo, Chung-Yau

    2010-01-01

    Over the last decade, surgeons have witnessed dramatic changes in surgical practice as a result of the introduction of new technological advancement. Some of these changes include refinement of techniques in thyroid cancer surgery. The development of various endoscopic thyroidectomy techniques, the addition of the da Vinci robot, and the use of operative adjuncts in thyroid surgery, such as intraoperative neuromonitoring and quick intraoperative parathyroid hormone, have made thyroid cancer surgery not only safer and better accepted by patients with thyroid cancer but also offer them more surgical treatment options.

  13. Using Program Theory-Driven Evaluation Science to Crack the Da Vinci Code

    ERIC Educational Resources Information Center

    Donaldson, Stewart I.

    2005-01-01

    Program theory-driven evaluation science uses substantive knowledge, as opposed to method proclivities, to guide program evaluations. It aspires to update, clarify, simplify, and make more accessible the evolving theory of evaluation practice commonly referred to as theory-driven or theory-based evaluation. The evaluator in this chapter provides a…

  14. Leonardo da Vinci's Geology: The Authenticity of The Virgin of the Rocks

    NASA Astrophysics Data System (ADS)

    Pizzorusso, Ann

    2017-04-01

    Viewed from a geological perspective, all of Leonardo's paintings and drawings reveal a remarkable fidelity to nature. The Virgin of the Rocks in the National Gallery in London (1495-1508), attributed to him, displays no such fidelity. If we compare it to the Virgin of the Rocks in the Louvre in Paris (1483-86) whose geological accuracy is astounding, we cannot help questioning whether Leonardo painted the background in the National Gallery work. Over the centuries, various arguments have called into question the attribution of the National Gallery painting to Leonardo. Scholars have analyzed the brush strokes, undertaken document searches and tried to prove definitively that Leonardo produced the National Gallery version. However, there have always been doubts, naysayers and many unanswered questions concerning its authenticity. The fact that attribution of the work has been the subject of such controversy throughout history suggests that new diagnostic means of determining authenticity is in order. A comparison of the representations of geological formations in the two paintings offers such means. It seems unlikely that the same person could have portrayed rock formations so accurately in the Louvre work and so incongruously in the National Gallery painting.

  15. 76 FR 12627 - Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 42, DA 42 NG, and DA 42 M-NG...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ... Industries GmbH Models DA 42, DA 42 NG, and DA 42 M-NG Airplanes AGENCY: Federal Aviation Administration (FAA... on Diamond aeroplanes, the majority of which were DA 40. In additional, at least 18 doors have been... conditions) while the aeroplane was parked. All DA 40 and DA 42 aeroplanes have a system installed that...

  16. Validation of a virtual reality-based robotic surgical skills curriculum.

    PubMed

    Connolly, Michael; Seligman, Johnathan; Kastenmeier, Andrew; Goldblatt, Matthew; Gould, Jon C

    2014-05-01

    The clinical application of robotic-assisted surgery (RAS) is rapidly increasing. The da Vinci Surgical System™ is currently the only commercially available RAS system. The skills necessary to perform robotic surgery are unique from those required for open and laparoscopic surgery. A validated laparoscopic surgical skills curriculum (fundamentals of laparoscopic surgery or FLS™) has transformed the way surgeons acquire laparoscopic skills. There is a need for a similar skills training and assessment tool specific for robotic surgery. Based on previously published data and expert opinion, we developed a robotic skills curriculum. We sought to evaluate this curriculum for evidence of construct validity (ability to discriminate between users of different skill levels). Four experienced surgeons (>20 RAS) and 20 novice surgeons (first-year medical students with no surgical or RAS experience) were evaluated. The curriculum comprised five tasks utilizing the da Vinci™ Skills Simulator (Pick and Place, Camera Targeting 2, Peg Board 2, Matchboard 2, and Suture Sponge 3). After an orientation to the robot and a period of acclimation in the simulator, all subjects completed three consecutive repetitions of each task. Computer-derived performance metrics included time, economy of motion, master work space, instrument collisions, excessive force, distance of instruments out of view, drops, missed targets, and overall scores (a composite of all metrics). Experienced surgeons significantly outperformed novice surgeons in most metrics. Statistically significant differences were detected for each task in regards to mean overall scores and mean time (seconds) to completion. The curriculum we propose is a valid method of assessing and distinguishing robotic surgical skill levels on the da Vinci Si™ Surgical System. Further study is needed to establish proficiency levels and to demonstrate that training on the simulator with the proposed curriculum leads to improved robotic

  17. Autocorrelation descriptor improvements for QSAR: 2DA_Sign and 3DA_Sign

    NASA Astrophysics Data System (ADS)

    Sliwoski, Gregory; Mendenhall, Jeffrey; Meiler, Jens

    2016-03-01

    Quantitative structure-activity relationship (QSAR) is a branch of computer aided drug discovery that relates chemical structures to biological activity. Two well established and related QSAR descriptors are two- and three-dimensional autocorrelation (2DA and 3DA). These descriptors encode the relative position of atoms or atom properties by calculating the separation between atom pairs in terms of number of bonds (2DA) or Euclidean distance (3DA). The sums of all values computed for a given small molecule are collected in a histogram. Atom properties can be added with a coefficient that is the product of atom properties for each pair. This procedure can lead to information loss when signed atom properties are considered such as partial charge. For example, the product of two positive charges is indistinguishable from the product of two equivalent negative charges. In this paper, we present variations of 2DA and 3DA called 2DA_Sign and 3DA_Sign that avoid information loss by splitting unique sign pairs into individual histograms. We evaluate these variations with models trained on nine datasets spanning a range of drug target classes. Both 2DA_Sign and 3DA_Sign significantly increase model performance across all datasets when compared with traditional 2DA and 3DA. Lastly, we find that limiting 3DA_Sign to maximum atom pair distances of 6 Å instead of 12 Å further increases model performance, suggesting that conformational flexibility may hinder performance with longer 3DA descriptors. Consistent with this finding, limiting the number of bonds in 2DA_Sign from 11 to 5 fails to improve performance.

  18. Origin of the DA and non-DA white dwarf stars

    NASA Technical Reports Server (NTRS)

    Shipman, Harry L.

    1989-01-01

    Various proposals for the bifurcation of the white dwarf cooling sequence are reviewed. 'Primordial' theories, in which the basic bifurcation of the white dwarf sequence is rooted in events predating the white dwarf stage of stellar evolution, are discussed, along with the competing 'mixing' theories in which processes occurring during the white dwarf stage are responsible for the existence of DA or non-DA stars. A new proposal is suggested, representing a two-channel scenario. In the DA channel, some process reduces the hydrogen layer mass to the value of less than 10 to the -7th. The non-DA channel is similar to that in the primordial scenario. These considerations suggest that some mechanism operates in both channels to reduce the thickness of the outermost layer of the white dwarf. It is also noted that accretion from the interstellar medium has little to do with whether a particular white dwarf becomes a DA or a non-DA star.

  19. Evaluation of Surgical Devices Using an Artificial Pediatric Thoracic Model: A Comparison Between Robot-Assisted Thoracoscopic Suturing Versus Conventional Video-Assisted Thoracoscopic Suturing.

    PubMed

    Takazawa, Shinya; Ishimaru, Tetsuya; Harada, Kanako; Deie, Kyoichi; Hinoki, Akinari; Uchida, Hiroo; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi; Fujishiro, Jun

    2018-05-01

    Pediatric robot-assisted surgery is increasingly being performed, but it is difficult to perform this procedure in infants. A pediatric thoracoscopic model of a 1-year-old patient was developed in our previous study, and this model was used to evaluate the use of a surgical robot for infant surgery. Eight pediatric surgeons performed an intracorporeal suturing and knot-tying task using the da Vinci Xi Robotic Surgical System. The task completion time, number of needle manipulations, and force applied during suturing of the robot-assisted thoracoscopic surgery (RATS) group were compared with those of the video-assisted thoracoscopic surgery (VATS) group whose data had been collected from the same 8 surgeons in our previous study. The RATS group showed a significantly shorter completion time than the VATS group in the knot-tying phase (P = .016) and in the total phase (P = .0078). The RATS group showed a significantly smaller number of manipulations than the VATS group in the total phase (P = .039). The RATS group showed a significantly smaller pushing force index than the VATS group in the suturing phase (P = .031), knot-tying phase (P = .031), and in the total phase (P = .031). A seventh rib in the model was dislocated in all RATS group cases. The da Vinci Surgical System might be useful in infants because of fast movement and small pushing force. However, the robotic 8 mm instruments were too large for use in the thoracic cavity of the 1-year-old infant.

  20. Robotic mitral valve surgery: overview, methodology, results, and perspective

    PubMed Central

    2016-01-01

    Robotic mitral valve repair began in 1998 and has advanced remarkably. It arose from an interest in reducing patient trauma by operating through smaller incisions with videoscopic assistance. In the United States, following two clinical trials, the FDA approved the daVinci Surgical System in 2002 for intra-cardiac surgery. This device has undergone three iterations, eventuating in the current daVinci XI. At present it is the only robotic device approved for mitral valve surgery. Many larger centers have adopted its use as part of their routine mitral valve repair armamentarium. Although these operations have longer perfusion and arrest times, complications have been either similar or less than other traditional methods. Preoperative screening is paramount and leads to optimal patient selection and outcomes. There are clear contraindications, both relative and absolute, that must be considered. Three-dimensional (3D) echocardiographic studies optimally guide surgeons in operative planning. Herein, we describe the selection criteria as well as our operative management during a robotic mitral valve repair. Major complications are detailed with tips to avoid their occurrence. Operative outcomes from the author’s series as well as those from the largest experiences in the United States are described. They show that robotic mitral valve repair is safe and effective, as well as economically reasonable due to lower costs of hospitalization. Thus, the future of this operative technique is bright for centers adopting the “heart team” approach, adequate clinical volume and a dedicated and experienced mitral repair surgeon. PMID:27942486

  1. Development of a precision multimodal surgical navigation system for lung robotic segmentectomy

    PubMed Central

    Soldea, Valentin; Lachkar, Samy; Rinieri, Philippe; Sarsam, Mathieu; Bottet, Benjamin; Peillon, Christophe

    2018-01-01

    Minimally invasive sublobar anatomical resection is becoming more and more popular to manage early lung lesions. Robotic-assisted thoracic surgery (RATS) is unique in comparison with other minimally invasive techniques. Indeed, RATS is able to better integrate multiple streams of information including advanced imaging techniques, in an immersive experience at the level of the robotic console. Our aim was to describe three-dimensional (3D) imaging throughout the surgical procedure from preoperative planning to intraoperative assistance and complementary investigations such as radial endobronchial ultrasound (R-EBUS) and virtual bronchoscopy for pleural dye marking. All cases were operated using the DaVinci SystemTM. Modelisation was provided by Visible Patient™ (Strasbourg, France). Image integration in the operative field was achieved using the Tile Pro multi display input of the DaVinci console. Our experience was based on 114 robotic segmentectomies performed between January 2012 and October 2017. The clinical value of 3D imaging integration was evaluated in 2014 in a pilot study. Progressively, we have reached the conclusion that the use of such an anatomic model improves the safety and reliability of procedures. The multimodal system including 3D imaging has been used in more than 40 patients so far and demonstrated a perfect operative anatomic accuracy. Currently, we are developing an original virtual reality experience by exploring 3D imaging models at the robotic console level. The act of operating is being transformed and the surgeon now oversees a complex system that improves decision making. PMID:29785294

  2. Evolution of robotic arms.

    PubMed

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  3. Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery.

    PubMed

    Pacchierotti, Claudio; Prattichizzo, Domenico; Kuchenbecker, Katherine J

    2016-02-01

    Despite its expected clinical benefits, current teleoperated surgical robots do not provide the surgeon with haptic feedback largely because grounded forces can destabilize the system's closed-loop controller. This paper presents an alternative approach that enables the surgeon to feel fingertip contact deformations and vibrations while guaranteeing the teleoperator's stability. We implemented our cutaneous feedback solution on an Intuitive Surgical da Vinci Standard robot by mounting a SynTouch BioTac tactile sensor to the distal end of a surgical instrument and a custom cutaneous display to the corresponding master controller. As the user probes the remote environment, the contact deformations, dc pressure, and ac pressure (vibrations) sensed by the BioTac are directly mapped to input commands for the cutaneous device's motors using a model-free algorithm based on look-up tables. The cutaneous display continually moves, tilts, and vibrates a flat plate at the operator's fingertip to optimally reproduce the tactile sensations experienced by the BioTac. We tested the proposed approach by having eighteen subjects use the augmented da Vinci robot to palpate a heart model with no haptic feedback, only deformation feedback, and deformation plus vibration feedback. Fingertip deformation feedback significantly improved palpation performance by reducing the task completion time, the pressure exerted on the heart model, and the subject's absolute error in detecting the orientation of the embedded plastic stick. Vibration feedback significantly improved palpation performance only for the seven subjects who dragged the BioTac across the model, rather than pressing straight into it.

  4. Italy flags scientific shortcomings

    NASA Astrophysics Data System (ADS)

    Cartlidge, Edwin

    2008-04-01

    The land that gave us Leonardo da Vinci, Galileo Galilei and Enrico Fermi does not regard science as part of culture, but it must do so if it is to avoid being left behind economically and intellectually. That is the message from a working group of 18 academics, sponsored by the Italian government, to find ways of improving the quantity, quality and public perception of science in the country. The group has now put forward a range of measures to combat what the group's chair, left-wing politician and Siena University law professor Luigi Berlinguer, describes as a "national emergency".

  5. Composition and stratigraphy of the paint layers: investigation on the Madonna dei Fusi by ion beam analysis techniques

    NASA Astrophysics Data System (ADS)

    Grassi, N.

    2005-06-01

    In the framework of the extensive study on the wood painting "Madonna dei fusi" attributed to Leonardo da Vinci, Ion Beam Analysis (IBA) techniques were used at the Florence accelerator laboratory to get information about the elemental composition of the paint layers. After a brief description of the basic principle and the general features of IBA techniques, we will illustrate in detail how the analysis allowed us to characterise the pigments of original and restored areas and the substrate composition, and to obtain information about the stratigraphy of the painting, also providing an estimate of the paint layer thickness.

  6. Differential PIXE for investigating the layer structure of paintings

    NASA Astrophysics Data System (ADS)

    Mandò, P. A.; Fedi, M. E.; Grassi, N.; Migliori, A.

    2005-09-01

    This paper reports an example of how the differential PIXE technique can be successfully applied to the investigation of wood or canvas paintings. The work analysed is a famous wood painting by Leonardo da Vinci, the "Madonna dei fusi" (ex-Reford version, 1501), chosen for a pilot study in a wide international project aimed at analysing Leonardo's works of art by means of non-destructive techniques. While illustrating the results obtained concerning the identification of pigments and the discrimination of the stratigraphy of layers, the merits and limits of differential PIXE in general are pointed out.

  7. Miniature in vivo robotics and novel robotic surgical platforms.

    PubMed

    Shah, Bhavin C; Buettner, Shelby L; Lehman, Amy C; Farritor, Shane M; Oleynikov, Dmitry

    2009-05-01

    Robotic surgical systems, such as the da Vinci Surgical System (Intuitive Surgical, Inc., Sunnyvale, California), have revolutionized laparoscopic surgery but are limited by large size, increased costs, and limitations in imaging. Miniature in vivo robots are being developed that are inserted entirely into the peritoneal cavity for laparoscopic and natural orifice transluminal endoscopic surgical (NOTES) procedures. In the future, miniature camera robots and microrobots should be able to provide a mobile viewing platform. This article discusses the current state of miniature robotics and novel robotic surgical platforms and the development of future robotic technology for general surgery and urology.

  8. Robotics, telesurgery and telementoring--their position in modern urological laparoscopy.

    PubMed

    Rassweiler, Jens; Frede, Thomas

    2002-01-01

    Laparoscopic surgery in general is handicapped by the reduction of the range of motion from six to four degrees of freedom. This has a major impact on technically difficult procedures such as laparoscopic radical prostatectomy. Solutions for this problems include the understanding of the geometry of laparoscopy with sophisticated training programs, but lie also in newly developed surgical robots, computer simulators and telementoring. This article evaluates the value of these alternatives based on own experiences and an analysis of the current literature. Own experiences with robot-assisted surgery include 406 laparoscopic radical prostatectomies using a voice-controlled camera-arm (AESOP) as well as 6 telesurgical interventions with the Da Vinci-system. Additionally, substantial experimental studies have been performed focussing on the geometry of laparoscopy and new training concepts such as perfused pelvitrainers and computer simulation. Moreover, the current literature of the last 10 years on telesurgery and telementoring has been reviewed. The geometry of laparoscopy includes the angles between the instruments which have to be in a range of 25 degrees to 45 degrees; the angles between the instrument and the working plane that should not exceed 55 degrees; and the angle between the shaft of the needle holder and the needle which has to be adapted according to the anatomical situation in range of 90 to 110 degrees. 3-D-systems did not yet proved to be effective due to handling problems such as shutter glasses, video-helmets or reduced brightness. At the moment, there are only two robotic surgical systems (ZEUS, Da Vinci) in clinical use for telesurgery, of which only the Da Vinci provides stereovision and all six degrees of freedom (DOF). In the meantime, more than 200 laparoscopic radical prostatectomies have been performed with this system. Until now, however, there was no evidence of any advantages over the conventional laparoscopic approach. The ZEUS in

  9. Future of robotic surgery in urology.

    PubMed

    Rassweiler, Jens J; Autorino, Riccardo; Klein, Jan; Mottrie, Alex; Goezen, Ali Serdar; Stolzenburg, Jens-Uwe; Rha, Koon H; Schurr, Marc; Kaouk, Jihad; Patel, Vipul; Dasgupta, Prokar; Liatsikos, Evangelos

    2017-12-01

    To provide a comprehensive overview of the current status of the field of robotic systems for urological surgery and discuss future perspectives. A non-systematic literature review was performed using PubMed/Medline search electronic engines. Existing patents for robotic devices were researched using the Google search engine. Findings were also critically analysed taking into account the personal experience of the authors. The relevant patents for the first generation of the da Vinci platform will expire in 2019. New robotic systems are coming onto the stage. These can be classified according to type of console, arrangement of robotic arms, handles and instruments, and other specific features (haptic feedback, eye-tracking). The Telelap ALF-X robot uses an open console with eye-tracking, laparoscopy-like handles with haptic feedback, and arms mounted on separate carts; first clinical trials with this system were reported in 2016. The Medtronic robot provides an open console using three-dimensional high-definition video technology and three arms. The Avatera robot features a closed console with microscope-like oculars, four arms arranged on one cart, and 5-mm instruments with six degrees of freedom. The REVO-I consists of an open console and a four-arm arrangement on one cart; the first experiments with this system were published in 2016. Medicaroid uses a semi-open console and three robot arms attached to the operating table. Clinical trials of the SP 1098-platform using the da Vinci Xi for console-based single-port surgery were reported in 2015. The SPORT robot has been tested in animal experiments for single-port surgery. The SurgiBot represents a bedside solution for single-port surgery providing flexible tube-guided instruments. The Avicenna Roboflex has been developed for robotic flexible ureteroscopy, with promising early clinical results. Several console-based robots for laparoscopic multi- and single-port surgery are expected to come to market within the

  10. The major histocompatibility complex genes impact pain response in DA and DA.1U rats.

    PubMed

    Guo, Yuan; Yao, Fan-Rong; Cao, Dong-Yuan; Li, Li; Wang, Hui-Sheng; Xie, Wen; Zhao, Yan

    2015-08-01

    Our recent studies have shown that the difference in basal pain sensitivity to mechanical and thermal stimulation between Dark-Agouti (DA) rats and a novel congenic DA.1U rats is major histocompatibility complex (MHC) genes dependent. In the present study, we further used DA and DA.1U rats to investigate the role of MHC genes in formalin-induced pain model by behavioral, electrophysiological and immunohistochemical methods. Behavioral results showed biphasic nociceptive behaviors increased significantly following the intraplantar injection of formalin in the hindpaw of DA and DA.1U rats. The main nociceptive behaviors were lifting and licking, especially in DA rats (P<0.001 and P<0.01). The composite pain scores (CPS) in DA rats were significantly higher than those in DA.1U rats in both phases of the formalin test (P<0.01). Electrophysiological results also showed the biphasic increase in discharge rates of C and Aδ fibers of L5 dorsal root in the two strains, and the net change of the discharge rate of DA rats was significantly higher than that of DA.1U rats (P<0.05). The mechanical thresholds decreased after formalin injection in both strains (P<0.01), and the net change in the mechanical threshold in DA was greater than that in DA.1U rats (P<0.05). The expression of RT1-B, representation of MHC class II molecule, in laminae I-II of L4/5 spinal cord in DA rats was significantly higher than that in DA.1U rats in the respective experimental group (P<0.05). These results suggested that both DA and DA.1U rats exhibited nociceptive responses in formalin-induced pain model and DA rats were more sensitive to noxious chemical stimulus than DA.1U rats, indicating that MHC genes might contribute to the difference in pain sensitivity. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. [From Leonardo Da Vinci to present days; from the history of antiplague costume].

    PubMed

    Kalmykov, A A; Aminev, R M; Korneev, A G; Polyakov, V S; Artebyakin, S V

    2016-01-01

    As a prototype of the antiplague costume can be considered a special clothing, which physicians in medieval Europe wear for protection in plague nidus. Inventor of the first antiplague costume is considered to be a French doctor Charles de Lorme (1619). Much later, in 1878, a Russian professor Pashutin V V offered to use a costume, which looked like a hermetically sealed "bag" with a special breathing device aimed at protection of medical staff. Later, professor O.I. Dogel's respirator became well-known (1889). At the beginning of 20th century as part of the antiplague costume was used a charcoal filter mask, invented by Zelinsky N.D. Requirements to order the use of modern means of individual protection when working in nidus of especially dangerous infections identified sanitary-epidemiological rules, which reflect issues of laboratory workers working and protective clothing, respiratory protection, and view, especially operation, the procedure of putting on, removing and disinfecting antiplague costumes, pneumocostumes, pneumohelmets, isolation suits, gas-protection boxes, etc.

  12. Building Skills and Qualifications among SME Employees. Leonardo da Vinci Good Practices Series.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document profiles 10 European programs that exemplify good practice in building skills and qualifications among employees of small and medium enterprises (SMEs). The programs profiled are as follows: (1) TRICTSME (a program providing World Wide Web-based information and communication technologies training for SMEs in manufacturing); (2)…

  13. Back to the Drawing Board Reconstructing DaVinci's Vitruvian Man to Teach Anatomy

    ERIC Educational Resources Information Center

    Babaian, C.

    2009-01-01

    In today's high tech world, one hardly expects to see the original chalkboard or blackboard utilized in research, teaching, or scientific communication, but having spent an equal number of years doing both art and biology and dabbling in computer graphics, the author has found the simple technology of the chalkboard and chalk to have incredible…

  14. Social and Occupational Integration of Disadvantaged People. Leonardo da Vinci Good Practices Series.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document profiles nine European programs that exemplify good practice in social and occupational integration of disadvantaged people. The programs profiled are as follows: (1) Restaurant Venezia (a CD-ROM program to improve the reading and writing skills of young people in Luxembourg who have learning difficulties); (2) an integrated…

  15. Virtual reality robotic surgical simulation: an analysis of gynecology trainees.

    PubMed

    Sheth, Sangini S; Fader, Amanda N; Tergas, Ana I; Kushnir, Christina L; Green, Isabel C

    2014-01-01

    To analyze the learning curves of gynecology trainees on several virtual reality da Vinci Skills Simulator exercises. Prospective cohort pilot study. Academic hospital-based gynecology training program. Novice robotic surgeons from a gynecology training program. Novice robotic surgeons from an academic gynecology training program completed 10 repetitions of 4 exercises on the da Vinci Skills Simulator: matchboard, ring and rail, suture sponge, and energy switching. Performance metrics measured included time to completion, economy of instrument movement, excessive force, collisions, master workspace range, missed targets, misapplied energy, critical errors, and overall score. Statistical analyses were conducted to define the learning curve for trainees and the optimal number of repetitions for each exercise. A total of 34 participants were enrolled, of which 9 were medical students, 22 were residents, and 3 were fellows. There was a significant improvement in performance between the 1st and 10th repetitions across multiple metrics for all exercises. Senior trainees performed the suture exercise significantly faster than the junior trainees during the first and last repetitions (p = 0.004 and p = 0.003, respectively). However, the performance gap between seniors and juniors narrowed significantly by the 10th repetition. The mean number of repetitions required to achieve performance plateau ranged from 6.4 to 9.3. Virtual reality robotic simulation improves ability through repetition at all levels of training. Further, a performance plateau may exist during a single training session. Larger studies are needed to further define the most high-yield simulator exercises, the ideal number of repetitions, and recommended intervals between training sessions to improve operative performance. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Initial validation of a virtual-reality robotic simulator.

    PubMed

    Lendvay, Thomas S; Casale, Pasquale; Sweet, Robert; Peters, Craig

    2008-09-01

    Robotic surgery is an accepted adjunct to minimally invasive surgery, but training is restricted to console time. Virtual-reality (VR) simulation has been shown to be effective for laparoscopic training and so we seek to validate a novel VR robotic simulator. The American Urological Association (AUA) Office of Education approved this study. Subjects enrolled in a robotics training course at the 2007 AUA annual meeting underwent skills training in a da Vinci dry-lab module and a virtual-reality robotics module which included a three-dimensional (3D) VR robotic simulator. Demographic and acceptability data were obtained, and performance metrics from the simulator were compared between experienced and nonexperienced roboticists for a ring transfer task. Fifteen subjects-four with previous robotic surgery experience and 11 without-participated. Nine subjects were still in urology training and nearly half of the group had reported playing video games. Overall performance of the da Vinci system and the simulator were deemed acceptable by a Likert scale (0-6) rating of 5.23 versus 4.69, respectively. Experienced subjects outperformed nonexperienced subjects on the simulator on three metrics: total task time (96 s versus 159 s, P < 0.02), economy of motion (1,301 mm versus 2,095 mm, P < 0.04), and time the telemanipulators spent outside of the center of the platform's workspace (4 s versus 35 s, P < 0.02). This is the first demonstration of face and construct validity of a virtual-reality robotic simulator. Further studies assessing predictive validity are ultimately required to support incorporation of VR robotic simulation into training curricula.

  17. Electrosurgical injuries during robot assisted surgery: insights from the FDA MAUDE database

    NASA Astrophysics Data System (ADS)

    Fuller, Andrew; Vilos, George A.; Pautler, Stephen E.

    2012-02-01

    Introduction: The da Vinci surgical system requires the use of electrosurgical instruments. The re-use of such instruments creates the potential for stray electrical currents from capacitive coupling and/or insulation failure with subsequent injury. The morbidity of such injuries may negate many of the benefits of minimally invasive surgery. We sought to evaluate the rate and nature of electrosurgical injury (ESI) associated with this device. Methods: The Manufacturer and User Facility Device Experience (MAUDE) database is administered by the US Food and Drug Administration (FDA) and reports adverse events related to medical devices in the United States. We analyzed all incidents in the context of robotic surgery between January 2001 and June 2011 to identify those related to the use of electrosurgery. Results: In the past decade, a total of 605 reports have been submitted to the FDA with regard to adverse events related to the da Vinci robotic surgical platform. Of these, 24 (3.9%) were related to potential or actual ESI. Nine out of the 24 cases (37.5%) resulted in additional surgical intervention for repair. There were 6 bowel injuries of which only one was recognized and managed intra-operatively. The remainder required laparotomy between 5 and 8 days after the initial robotic procedure. Additionally, there were 3 skin burns. The remaining cases required conservative management or resulted in no harm. Conclusion: ESI in the context of robotic surgery is uncommon but remains under-recognized and under-reported. Surgeons performing robot assisted surgery should be aware that ESI can occur with robotic instruments and vigilance for intra- and post-operative complications is paramount.

  18. Robot-assisted laparoscopic ultrasonography for hepatic surgery.

    PubMed

    Schneider, Caitlin M; Peng, Peter D; Taylor, Russell H; Dachs, Gregory W; Hasser, Christopher J; DiMaio, Simon P; Choti, Michael A

    2012-05-01

    This study describes and evaluates a novel, robot-assisted laparoscopic ultrasonographic device for hepatic surgery. Laparoscopic liver surgery is being performed with increasing frequency. One major drawback of this approach is the limited capability of intraoperative ultrasonography (IOUS) using standard laparoscopic devices. Robotic surgery systems offer the opportunity to develop new tools to improve techniques in minimally invasive surgery. This study evaluates a new integrated ultrasonography (US) device with the da Vinci Surgical System for laparoscopic visualization, comparing it with conventional handheld laparoscopic IOUS for performing key tasks in hepatic surgery. A prototype laparoscopic IOUS instrument was developed for the da Vinci Surgical System and compared with a conventional laparoscopic US device in simulation tasks: (1) In vivo porcine hepatic visualization and probe manipulation, (2) lesion detection accuracy, and (3) biopsy precision. Usability was queried by poststudy questionnaire. The robotic US proved better than conventional laparoscopic US in liver surface exploration (85% success vs 73%; P = .030) and tool manipulation (79% vs 57%; P = .028), whereas no difference was detected in lesion identification (63 vs 58; P = .41) and needle biopsy tasks (57 vs 48; P = .11). Subjects found the robotic US to facilitate better probe positioning (80%), decrease fatigue (90%), and be more useful overall (90%) on the post-task questionnaire. We found this robot-assisted IOUS system to be practical and useful in the performance of important tasks required for hepatic surgery, outperforming free-hand laparoscopic IOUS for certain tasks, and was more subjectively usable to the surgeon. Systems such as this may expand the use of robotic surgery for complex operative procedures requiring IOUS. Copyright © 2012 Mosby, Inc. All rights reserved.

  19. Upper quadrant port placement for robot-assisted renal surgery: implementation of the Floating Arm and the XL Protype.

    PubMed

    Totonchi, Samer; Elgin, Robert; Monahan, Michael; Johnston, William K

    2014-08-01

    Abstract Background and Purpose: Placement of the fourth arm (4th arm) in the lower quadrant (LQ) is commonly described for robot-assisted renal surgical procedures but has anatomic restrictions and limited ergonomics. An alternative, upper quadrant (UQ) location is desirable, but patient habitus and spacing may restrict robotic attachment. We investigate current trends in 4th arm port placement and propose an alternative method at attaching the robot-the "Floating Arm" (FLA). Robotic surgeons from the Endourological Society were surveyed. A 20-cm extra-long (XL Protype) da Vinci instrument was developed for the FLA technique. A dry lab allowed quantitative comparison of spacing and ranges of motion for standard da Vinci ports (dVP), bariatric dVP, telescoping dVP, and FLA. There were 108 respondents who participated. Half of the respondents avoid using the 4th arm (30% lack of need and 20% because of interference). The majority (90%) typically positions the 4th arm in the LQ, but many reported limitations in this location. Few (5%) place 4th arm in the UQ, while most (73%) have never heard of UQ placement. Existing techniques may increase shoulder height clearance but inversely shorten the working length of the instrument intracorporeally. Alternatively, the XL Protype significantly increased the shoulder length and maintained available working distances intracorporeally. Adjacent arm interference angle was essentially identical (27 degrees) for all ports except a greater range of movement for the XL Protype (35 degrees). Few surgeons are using an UQ positioning or use techniques to improve attachment of the 4th arm. The greatest freedom may be obtained by implementing the FLA, but this necessitates production of a longer instrument.

  20. A motorized ultrasound system for MRI-ultrasound fusion guided prostatectomy

    NASA Astrophysics Data System (ADS)

    Seifabadi, Reza; Xu, Sheng; Pinto, Peter; Wood, Bradford J.

    2016-03-01

    Purpose: This study presents MoTRUS, a motorized transrectal ultrasound system, to enable remote navigation of a transrectal ultrasound (TRUS) probe during da Vinci assisted prostatectomy. MoTRUS not only provides a stable platform to the ultrasound probe, but also allows the physician to navigate it remotely while sitting on the da Vinci console. This study also presents phantom feasibility study with the goal being intraoperative MRI-US image fusion capability to bring preoperative MR images to the operating room for the best visualization of the gland, boundaries, nerves, etc. Method: A two degree-of-freedom probe holder is developed to insert and rotate a bi-plane transrectal ultrasound transducer. A custom joystick is made to enable remote navigation of MoTRUS. Safety features have been considered to avoid inadvertent risks (if any) to the patient. Custom design software has been developed to fuse pre-operative MR images to intraoperative ultrasound images acquired by MoTRUS. Results: Remote TRUS probe navigation was evaluated on a patient after taking required consents during prostatectomy using MoTRUS. It took 10 min to setup the system in OR. MoTRUS provided similar capability in addition to remote navigation and stable imaging. No complications were observed. Image fusion was evaluated on a commercial prostate phantom. Electromagnetic tracking was used for the fusion. Conclusions: Motorized navigation of the TRUS probe during prostatectomy is safe and feasible. Remote navigation provides physician with a more precise and easier control of the ultrasound image while removing the burden of manual manipulation of the probe. Image fusion improved visualization of the prostate and boundaries in a phantom study.

  1. Robotic totally endoscopic triple coronary artery bypass grafting on the arrested heart: report of the first successful clinical case.

    PubMed

    Bonatti, Johannes; Rehman, Atiq; Schwartz, Kimberly; Deshpande, Seema; Kon, Zachary; Lehr, Eric; Zimrin, David; Griffith, Bartley

    2010-12-01

    Robotic technology enables "port only" totally endoscopic coronary artery bypass grafting (TECAB). During early procedure development only single bypass grafts were feasible. Because current referral practice for coronary bypass surgery mostly includes multivessel disease, performance of multiple endoscopic bypass grafts is desirable. We report a case in which a patient received a right internal mammary artery bypass graft to the left anterior descending artery and a left internal mammary artery jump graft to 2 obtuse marginal branches. The procedure was performed through 5 ports on the arrested heart using the daVinci S robotic surgical system. This is the first reported triple bypass grafting procedure using an arrested heart approach.

  2. Image-based tracking of the suturing needle during laparoscopic interventions

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Kroehnert, A.; Bodenstedt, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.

    2015-03-01

    One of the most complex and difficult tasks for surgeons during minimally invasive interventions is suturing. A prerequisite to assist the suturing process is the tracking of the needle. The endoscopic images provide a rich source of information which can be used for needle tracking. In this paper, we present an image-based method for markerless needle tracking. The method uses a color-based and geometry-based segmentation to detect the needle. Once an initial needle detection is obtained, a region of interest enclosing the extracted needle contour is passed on to a reduced segmentation. It is evaluated with in vivo images from da Vinci interventions.

  3. Early experiences of endoscopic procedures in general surgery assisted by a computer-enhanced surgical system.

    PubMed

    Hashizume, M; Shimada, M; Tomikawa, M; Ikeda, Y; Takahashi, I; Abe, R; Koga, F; Gotoh, N; Konishi, K; Maehara, S; Sugimachi, K

    2002-08-01

    We performed a variety of complete total endoscopic general surgical procedures, including colon resection, distal gastrectomy, and splenectomy, successfully with the assistance of the da Vinci computer-enhanced surgical system. The robotic system allowed us to manipulate the endoscopic instruments as effectively as during open surgery. It enhanced visualization of both the operative field and precision of the necessary techniques, as well as being less stressful for the endoscopic operating team. This technological innovation can therefore help surgeons overcome many of the difficulties associated with the endoscopic approach and thus has the potential to enable more precise, safer, and more minimally invasive surgery in the future.

  4. The comeback of hand drawing in modern life sciences.

    PubMed

    Chabrier, Renaud; Janke, Carsten

    2018-03-01

    Scientific manuscripts are full of images. Since the birth of the life sciences, these images were in a form of hand drawings, with great examples from da Vinci, Hooke, van Leeuwenhoek, Remak, Buffon, Bovery, Darwin, Huxley, Haeckel and Gray's Anatomy to name a few. However, in the course of the past century, photographs and simplified schematics have gradually taken over as a way of illustrating scientific data and concepts, assuming that these are 'accurate' representations of the truth. Here, we argue for the importance of reviving the art of scientific drawings as a way of effectively communicating complex scientific ideas to both specialists and the general public.

  5. Development of a StandAlone Surgical Haptic Arm.

    PubMed

    Jones, Daniel; Lewis, Andrew; Fischer, Gregory S

    2011-01-01

    When performing telesurgery with current commercially available Minimally Invasive Robotic Surgery (MIRS) systems, a surgeon cannot feel the tool interactions that are inherent in traditional laparoscopy. It is proposed that haptic feedback in the control of MIRS systems could improve the speed, safety and learning curve of robotic surgery. To test this hypothesis, a standalone surgical haptic arm (SASHA) capable of manipulating da Vinci tools has been designed and fabricated with the additional ability of providing information for haptic feedback. This arm was developed as a research platform for developing and evaluating approaches to telesurgery, including various haptic mappings between master and slave and evaluating the effects of latency.

  6. [A Fragment Of De speculis comburentibus of Regiomontanus Copied by Toscanelli and Inserted in the Books of Leonardo (Codex Atlanticus, 611rb / 915ra)].

    PubMed

    Raynaud, Dominique

    2015-07-01

    This article studies a fragment on the conic sections that appear in the Codex Atlanticus, fols. 611rb/915ra. Arguments are put forward to assemble these two folios. Their comparison with the Latin texts available before 1500 shows that they derive from the De speculis comburentibus of Alhacen and the De speculis comburentibus of Regiomontanus, joined together in his autograph manuscript (Vienna, Oster. Nationalbibliothek, Cod. 5258). Having identified the sources, and discussed their mathematics, the issue of their transmission is targeted. It is shown that these notes were written by Paolo dal Pozzo Toscanelli, through whom they reached the notebooks of Leonardo da Vinci.

  7. Patterns-of-care and health economic analysis of robot-assisted radical prostatectomy in the Australian public health system.

    PubMed

    Basto, Marnique; Sathianathen, Niranjan; Te Marvelde, Luc; Ryan, Shane; Goad, Jeremy; Lawrentschuk, Nathan; Costello, Anthony J; Moon, Daniel A; Heriot, Alexander G; Butler, Jim; Murphy, Declan G

    2016-06-01

    To compare patterns of care and peri-operative outcomes of robot-assisted radical prostatectomy (RARP) with other surgical approaches, and to create an economic model to assess the viability of RARP in the public case-mix funding system. We retrospectively reviewed all radical prostatectomies (RPs) performed for localized prostate cancer in Victoria, Australia, from the Victorian Admitted Episode Dataset, a large administrative database that records all hospital inpatient episodes in Victoria. The first database, covering the period from July 2010 to April 2013 (n = 5 130), was used to compare length of hospital stay (LOS) and blood transfusion rates between surgical approaches. This was subsequently integrated into an economic model. A second database (n = 5 581) was extracted to cover the period between July 2010 and June 2013, three full financial years, to depict patterns of care and make future predictions for the 2014-2015 financial year, and to perform a hospital volume analysis. We then created an economic model to evaluate the incremental cost of RARP vs open RP (ORP) and laparoscopic RP (LRP), incorporating the cost-offset from differences in LOS and blood transfusion rate. The economic model constructs estimates of the diagnosis-related group (DRG) costs of ORP and LRP, adds the gross cost of the surgical robot (capital, consumables, maintenance and repairs), and manipulates these DRG costs to obtain a DRG cost per day, which can be used to estimate the cost-offset associated with RARP in comparison with ORP and LRP. Economic modelling was performed around a base-case scenario, assuming a 7-year robot lifespan and 124 RARPs performed per financial year. One- and two-way sensitivity analyses were performed for the four-arm da Vinci SHD, Si and Si dual surgical systems (Intuitive Surgical Ltd, Sunnyvale, CA, USA). We identified 5 581 patients who underwent RP in 20 hospitals in Victoria with an open, laparoscopic or robot-assisted surgical approach in the

  8. 75 FR 52292 - Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 40 and DA 40F Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... Industries GmbH Models DA 40 and DA 40F Airplanes AGENCY: Federal Aviation Administration (FAA), Department... new airworthiness directive (AD) for all Diamond Aircraft Industries GmbH Models DA 40 and DA 40F... received information from Diamond Aircraft Industries GmbH that the Models DA 40 and DA 40F airplanes have...

  9. Renaissance Neurosurgery: Italy's Iconic Contributions.

    PubMed

    Nanda, Anil; Khan, Imad Saeed; Apuzzo, Michael L

    2016-03-01

    Various changes in the sociopolitical milieu of Italy led to the increasing tolerance of the study of cadavers in the late Middle Ages. The efforts of Mondino de Liuzzi (1276-1326) and Guido da Vigevano (1280-1349) led to an explosion of cadaver-centric studies in centers such as Bologna, Florence, and Padua during the Renaissance period. Legendary scientists from this era, including Leonardo Da Vinci, Andreas Vesalius, Bartolomeo Eustachio, and Costanzo Varolio, furthered the study of neuroanatomy. The various texts produced during this period not only helped increase the understanding of neuroanatomy and neurophysiology but also led to the formalization of medical education. With increased understanding came new techniques to address various neurosurgical problems from skull fractures to severed peripheral nerves. The present study aims to review the major developments in Italy during the vibrant Renaissance period that led to major progress in the field of neurosurgery. Published by Elsevier Inc.

  10. Face, content, construct, and concurrent validity of a novel robotic surgery patient-side simulator: the Xperience™ Team Trainer.

    PubMed

    Xu, Song; Perez, Manuela; Perrenot, Cyril; Hubert, Nicolas; Hubert, Jacques

    2016-08-01

    To determine the face, content, construct, and concurrent validity of the Xperience™ Team Trainer (XTT) as an assessment tool of robotic surgical bed-assistance skills. Subjects were recruited during a robotic surgery curriculum. They were divided into three groups: the group RA with robotic bed-assistance experience, the group LS with laparoscopic surgical experience, and the control group without bed-assistance or laparoscopic experience. The subjects first performed two standard FLS exercises on a laparoscopic simulator for the assessment of basic laparoscopic skills. After that, they performed three virtual reality exercises on XTT, and then performed similar exercises on physical models on a da Vinci(®) box trainer. Twenty-eight persons volunteered for and completed the tasks. Most expert subjects agreed on the realism of XTT and the three exercises, and also their interest for teamwork and bed-assistant training. The group RA and the group LS demonstrated a similar level of basic laparoscopic skills. Both groups performed better than the control group on the XTT exercises (p < 0.05). The performance superiority of the group RA over LS was observed but not statistically significant. Correlation of performance was determined between the tests on XTT and on da Vinci(®) box trainer. The introduction of XTT facilitates the training of bedside assistants and emphasizes the importance of teamwork, which may change the paradigm of robotic surgery training in the near future. As an assessment tool of bed-assistance skills, XTT proves face, content, and concurrent validity. However, these results should be qualified considering the potential limitations of this exploratory study with a relatively small sample size. The training modules remain to be developed, and more complex and discriminative exercises are expected. Other studies will be needed to further determine construct validity in the future.

  11. Is it turquoise + fuchsia = purple or is it turquoise + fuchsia = blue?

    NASA Astrophysics Data System (ADS)

    Beretta, Giordano B.; Moroney, Nathan M.

    2011-01-01

    The first step in communicating color is to name it. The second step is color semiotics. The third step is introducing structure in the set of colors. In color education at all levels, this structure often takes the form of formulæ, like red + green = yellow, or turquoise + red = black. In recent times, Johannes Itten's color theory and its associated color wheel have been very influential, mostly through its impact on Bauhaus, although a number of color order systems and circles have been introduced over the centuries. Students get confused when they are trying to formulate the color name arithmetic using the structure of color order systems and concepts like complementary colors and opponent colors. Suddenly turquoise + fuchsia = purple instead of blue; purple and violet become blurred, and finally the student's head explodes under the epistemological pressures of Itten, Albers, Goethe, Runge, Newton, da Vinci, and all the other monsters of color structure. In this contribution we propose a systematic presentation of structure in color, from color theories to color naming. We start from the concept of color perception introduced by da Vinci and work ourselves through color measurement, color formation, and color naming, to develop the basis for a robust system based on table lookup and interpolation. One source of confusion is that color naming has been quite loose in color theory, where for example red can be used interchangeably with fuchsia, and blue with turquoise. Furthermore, common color terms are intermingled with technical colorant terms, for example cyan and aqua or fuchsia and magenta. We present the evolution of a few color terms, some of which have experienced a radical transition over the centuries, and describe an experiment showing the robustness of crowd-sourcing for color naming.

  12. Robotic surgery basic skills training: Evaluation of a pilot multidisciplinary simulation-based curriculum

    PubMed Central

    Foell, Kirsten; Finelli, Antonio; Yasufuku, Kazuhiro; Bernardini, Marcus Q.; Waddell, Thomas K.; Pace, Kenneth T.; Honey, R. John D.’A.; Lee, Jason Y.

    2013-01-01

    Purpose: Simulation-based training improves clinical skills, while minimizing the impact of the educational process on patient care. We present results of a pilot multidisciplinary, simulation-based robotic surgery basic skills training curriculum (BSTC) for robotic novices. Methods: A 4-week, simulation-based, robotic surgery BSTC was offered to the Departments of Surgery and Obstetrics & Gynecology (ObGyn) at the University of Toronto. The course consisted of various instructional strategies: didactic lecture, self-directed online-training modules, introductory hands-on training with the da Vinci robot (dVR) (Intuitive Surgical Inc., Sunnyvale, CA), and dedicated training on the da Vinci Skills Simulator (Intuitive Surgical Inc., Sunnyvale, CA) (dVSS). A third of trainees participated in competency-based dVSS training, all others engaged in traditional time-based training. Pre- and post-course skill testing was conducted on the dVR using 2 standardized skill tasks: ring transfer (RT) and needle passing (NP). Retention of skills was assessed at 5 months post-BSTC. Results: A total of 37 participants completed training. The mean task completion time and number of errors improved significantly post-course on both RT (180.6 vs. 107.4 sec, p < 0.01 and 3.5 vs. 1.3 sec, p < 0.01, respectively) and NP (197.1 vs. 154.1 sec, p < 0.01 and 4.5 vs. 1.8 sec, p = 0.04, respectively) tasks. No significant difference in performance was seen between specialties. Competency-based training was associated with significantly better post-course performance. The dVSS demonstrated excellent face validity. Conclusions: The implementation of a pilot multidisciplinary, simulation-based robotic surgery BSTC revealed significantly improved basic robotic skills among novice trainees, regardless of specialty or level of training. Competency-based training was associated with significantly better acquisition of basic robotic skills. PMID:24381662

  13. Visuospatial Aptitude Testing Differentially Predicts Simulated Surgical Skill.

    PubMed

    Hinchcliff, Emily; Green, Isabel; Destephano, Christopher; Cox, Mary; Smink, Douglas; Kumar, Amanika; Hokenstad, Erik; Bengtson, Joan; Cohen, Sarah

    2018-02-05

    To determine if visuospatial perception (VSP) testing is correlated to simulated or intraoperative surgical performance as rated by the American College of Graduate Medical Education (ACGME) milestones. Classification II-2 SETTING: Two academic training institutions PARTICIPANTS: 41 residents, including 19 Brigham and Women's Hospital and 22 Mayo Clinic residents from three different specialties (OBGYN, general surgery, urology). Participants underwent three different tests: visuospatial perception testing (VSP), Fundamentals of Laparoscopic Surgery (FLS®) peg transfer, and DaVinci robotic simulation peg transfer. Surgical grading from the ACGME milestones tool was obtained for each participant. Demographic and subject background information was also collected including specialty, year of training, prior experience with simulated skills, and surgical interest. Standard statistical analysis using Student's t test were performed, and correlations were determined using adjusted linear regression models. In univariate analysis, BWH and Mayo training programs differed in both times and overall scores for both FLS® peg transfer and DaVinci robotic simulation peg transfer (p<0.05 for all). Additionally, type of residency training impacted time and overall score on robotic peg transfer. Familiarity with tasks correlated with higher score and faster task completion (p= 0.05 for all except VSP score). There was no difference in VSP scores by program, specialty, or year of training. In adjusted linear regression modeling, VSP testing was correlated only to robotic peg transfer skills (average time p=0.006, overall score p=0.001). Milestones did not correlate to either VSP or surgical simulation testing. VSP score was correlated with robotic simulation skills but not with FLS skills or ACGME milestones. This suggests that the ability of VSP score to predict competence differs between tasks. Therefore, further investigation is required into aptitude testing, especially prior

  14. Robot-assisted partial nephrectomy: Superiority over laparoscopic partial nephrectomy.

    PubMed

    Shiroki, Ryoichi; Fukami, Naohiko; Fukaya, Kosuke; Kusaka, Mamoru; Natsume, Takahiro; Ichihara, Takashi; Toyama, Hiroshi

    2016-02-01

    Nephron-sparing surgery has been proven to positively impact the postoperative quality of life for the treatment of small renal tumors, possibly leading to functional improvements. Laparoscopic partial nephrectomy is still one of the most demanding procedures in urological surgery. Laparoscopic partial nephrectomy sometimes results in extended warm ischemic time and severe complications, such as open conversion, postoperative hemorrhage and urine leakage. Robot-assisted partial nephrectomy exploits the advantages offered by the da Vinci Surgical System to laparoscopic partial nephrectomy, equipped with 3-D vision and a better degree in the freedom of surgical instruments. The introduction of the da Vinci Surgical System made nephron-sparing surgery, specifically robot-assisted partial nephrectomy, safe with promising results, leading to the shortening of warm ischemic time and a reduction in perioperative complications. Even for complex and challenging tumors, robotic assistance is expected to provide the benefit of minimally-invasive surgery with safe and satisfactory renal function. Warm ischemic time is the modifiable factor during robot-assisted partial nephrectomy to affect postoperative kidney function. We analyzed the predictive factors for extended warm ischemic time from our robot-assisted partial nephrectomy series. The surface area of the tumor attached to the kidney parenchyma was shown to significantly affect the extended warm ischemic time during robot-assisted partial nephrectomy. In cases with tumor-attached surface area more than 15 cm(2) , we should consider switching robot-assisted partial nephrectomy to open partial nephrectomy under cold ischemia if it is imperative. In Japan, a nationwide prospective study has been carried out to show the superiority of robot-assisted partial nephrectomy to laparoscopic partial nephrectomy in improving warm ischemic time and complications. By facilitating robotic technology, robot-assisted partial nephrectomy

  15. Pancreatic enucleation using the da Vinci robotic surgical system: a report of 26 cases.

    PubMed

    Shi, Yusheng; Peng, Chenghong; Shen, Baiyong; Deng, Xiaxing; Jin, Jiabin; Wu, Zhichong; Zhan, Qian; Li, Hongwei

    2016-12-01

    As a tissue-sparing procedure, pancreatic enucleation has become an alternative for benign or borderline pancreatic tumours; it has been proved to be safe and feasible. To date, a large sample size of robotic pancreatic enucleation has not been reported. This study aimed to discuss the clinical evaluation and postoperative complications after robotic pancreatic enucleation and compare it with open surgery. Patients who underwent robotic or open pancreatic enucleation during December 2010-December 2014 at Shanghai Ruijin Hospital, affiliated with the Shanghai Jiaotong University School of Medicine in China, were included. Clinical data were collected and analysed. Patients were divided into an open group and a robotic group: 26 patients underwent robotic pancreatic enucleation, of whom 13 patients were female. The mean age was 51.7 years, the operation time was 125.7 ± 58.8 min, blood loss was 49.4 ± 33.4 ml and mean tumour size was 18.8 ± 7.9 mm; 17 patients underwent open pancreatic enucleation, of whom 11 were female. The mean age was 54.6 ± 17.2 min, blood loss was 198.5 ± 70.7 ml and mean tumour size was 3.5 ± 1.9 cm. Pathology included insulinomas, intrapancreatic mucinous neoplasmas (IPMNs), pancreatic neuro-endocrine tumours (PNETs), solid pseudopapillary tumours (SPTs) and serous cystadenomas (SCAs). Robotic pancreatic enucleations were associated with less trauma, shorter operation time, less blood loss and faster wound recovery compared with open pancreatic enucleation. Pancreatic fistulas (PFs) were the main complication that occurred in the robotic group; infection also occurred in the open group. All patients recovered after effective drainage and the use of somatostatin. The mean follow-up time was 25 months. No recurrence was discovered, and one patient in the open group suffered endocrine insufficiency. Robotic pancreatic enucleation is a safe and effective surgical procedure for pancreatic benign and borderline tumours. It produces less trauma than open pancreatic enucleation and might extend the indications for enucleation. The PF rate after surgery is still high and a long-term follow-up needs to be performed. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Moving towards Optimising Demand-Led Learning: The 2005-2007 ECUANET Leonardo Da Vinci Project

    ERIC Educational Resources Information Center

    Dealtry, Richard; Howard, Keith

    2008-01-01

    Purpose: The purpose of this paper is to present the key project learning points and outcomes as a guideline for the future quality management of demand-led learning and development. Design/methodology/approach: The research methodology was based upon a corporate university blueprint architecture and browser toolkit developed by a member of the…

  17. Depth of Monocular Elements in a Binocular Scene: The Conditions for da Vinci Stereopsis

    ERIC Educational Resources Information Center

    Cook, Michael; Gillam, Barbara

    2004-01-01

    Quantitative depth based on binocular resolution of visibility constraints is demonstrated in a novel stereogram representing an object, visible to 1 eye only, and seen through an aperture or camouflaged against a background. The monocular region in the display is attached to the binocular region, so that the stereogram represents an object which…

  18. In Pursuit of Social Betterment: A Proposal to Evaluate the Da Vinci Learning Model

    ERIC Educational Resources Information Center

    Henry, Gary T.

    2005-01-01

    The author presents a proposal that is roughly based on a contingency-based theory of evaluation developed in his book, "Evaluation: An Integrated Framework for Understanding, Guiding, and Improving Policies and Programs" (Mark, Henry, and Julnes, 2000). He and his coauthors stated in this book that social betterment was the ultimate goal of…

  19. The importance of being top-heavy: Intrinsic stability of flapping flight

    NASA Astrophysics Data System (ADS)

    Ristroph, Leif; Liu, Bin; Zhang, Jun

    2011-11-01

    We explore the stability of flapping flight in a model system that consists of a pyramid-shaped object that freely hovers in a vertically oscillating airflow. Such a ``bug'' not only generates sufficient aerodynamic force to keep aloft but also robustly maintains balance during free-flight. Flow visualization reveals that both weight support and intrinsic stability result from the periodic shedding of dipolar vortices. Counter-intuitively, the observed pattern of vortex shedding suggests that stability requires a high center-of-mass, which we verify by comparing the performance of top- and bottom-heavy bugs. Finally, we visit a zoo of other flapping flyers, including Mary Poppins' umbrella, a flying saucer or UFO, and Da Vinci's helicopter.

  20. Dreaming and Neuroesthetics

    PubMed Central

    Barcaro, Umberto; Paoli, Marco

    2015-01-01

    This paper, which is limited to the art of painting, aims to support the idea that a substantial insertion of concepts and methods drawn on dream psychology and dream neuroscience can contribute to the advancements of Neuroesthetics. The historical and scientific reasons are discussed that have determined the so far poor role played by the dream phenomenon in the developments of Neuroesthetics. In the light of recent advancements in psychophysiological research, a method of analyzing artistic products is proposed that is based on the recognition of precise features proper of the dreaming experience. Four examples are given for application of this method, regarding works by Giorgione, Leonardo da Vinci, Vermeer, and Millais, respectively. PMID:26157373

  1. Virtual Power Electronics: Novel Software Tools for Design, Modeling and Education

    NASA Astrophysics Data System (ADS)

    Hamar, Janos; Nagy, István; Funato, Hirohito; Ogasawara, Satoshi; Dranga, Octavian; Nishida, Yasuyuki

    The current paper is dedicated to present browser-based multimedia-rich software tools and e-learning curriculum to support the design and modeling process of power electronics circuits and to explain sometimes rather sophisticated phenomena. Two projects will be discussed. The so-called Inetele project is financed by the Leonardo da Vinci program of the European Union (EU). It is a collaborative project between numerous EU universities and institutes to develop state-of-the art curriculum in Electrical Engineering. Another cooperative project with participation of Japanese, European and Australian institutes focuses especially on developing e-learning curriculum, interactive design and modeling tools, furthermore on development of a virtual laboratory. Snapshots from these two projects will be presented.

  2. Robot Command Interface Using an Audio-Visual Speech Recognition System

    NASA Astrophysics Data System (ADS)

    Ceballos, Alexánder; Gómez, Juan; Prieto, Flavio; Redarce, Tanneguy

    In recent years audio-visual speech recognition has emerged as an active field of research thanks to advances in pattern recognition, signal processing and machine vision. Its ultimate goal is to allow human-computer communication using voice, taking into account the visual information contained in the audio-visual speech signal. This document presents a command's automatic recognition system using audio-visual information. The system is expected to control the laparoscopic robot da Vinci. The audio signal is treated using the Mel Frequency Cepstral Coefficients parametrization method. Besides, features based on the points that define the mouth's outer contour according to the MPEG-4 standard are used in order to extract the visual speech information.

  3. Optical spectroscopy of ancient paper and textiles

    NASA Astrophysics Data System (ADS)

    Missori, M.

    2016-03-01

    Ancient paper and textiles represent a striking example of optically inhomogenous materials whose optical responses are strongly governed by scattering effects. In order to recover the absorption coefficient from non-invasive and non-destructive reflectance measurements a specific approach based on Kubelka-Munk two-flux theory must be applied. In this way quantitative chemical information, such as chromophores concentration, can be obtained, as well as quantitative spectra of additional substances such as pigments or dyes. Results on a folio of the Codex on the Flight of Birds by Leonardo da Vinci and a linen cloth dated back to 1653 and called the Shroud of Arquata, a copy of the Shroud of Turin, will be presented.

  4. [Robotic pylorus-preserving pancreaticoduodenectomy : Video article].

    PubMed

    Aselmann, H; Egberts, J Hendrik; Beckmann, J Henrik; Stein, H; Schafmayer, C; Hinz, S; Reichert, B; Becker, T

    2017-05-01

    Pylorus-preserving pancreaticoduodenectomy is one of the most complex procedures in general surgery. Laparoscopic pancreaticoduodenectomy was initially described in 1994; however, its worldwide distribution is so far limited to only a few specialist centers. Robotic surgery using the DaVinci® system can overcome many limitations of laparoscopic surgery. The system is a promising tool for a more widespread introduction of minimally invasive surgery for pancreatic diseases. Mortality rates of 0-5% and pancreatic fistula rates of 0-35% are described in the literature; therefore, thorough complication management is crucial in the postoperative course. The video presents a robotic pylorus-preserving pancreaticoduodenectomy for periampullary carcinoma in a female patient.

  5. Totally robotic repair of atrioventricular septal defect in the adult.

    PubMed

    Gao, Changqing; Yang, Ming; Xiao, Cangsong; Zhang, Huajun

    2015-11-06

    Atrioventricular septal defect (AVSD) accounts for up to 3 % of congenital cardiac defects, which is routinely repaired via median sternotomy. Minimally invasive approach such as endoscopic or robotic assisted repair for AVSD has not been reported in the literature. With the experience with robotic mitral valve surgery and congenital defect repair, we initiated robotic AVSD repair in adults. In this report, we presented three cases of successful repair of partial and intermediate AVSD by using da Vinci SI surgical system (Intuitive Surgical, Inc., Sunnyvale, CA). Totally robotic AVSD repair via right atriotomy could be safely performed in adults and it may provide superior cosmesis with the comparable surgical outcome of the repair via sternotomy.

  6. Book Review

    NASA Astrophysics Data System (ADS)

    Harrison, Chris H.

    2017-11-01

    Have you ever been asked what you do for a living at a dinner party and had to say, "underwater acoustics", whereupon the questioner replies, "Oh, I shouldn't think there's much call for that - a bit specialised, isn't it?!"? "Well …", you splutter, "actually it's an important field of physics started up by Lord Rayleigh, or possibly even Leonardo da Vinci." One has to admit that it's probably a bit of a niche market. One also has to admit that in the 20th Century the interest was predominantly in defence where one aim was to be able to detect nuclear submarines, which were otherwise invisible, but the other aim was to help submarines be undetectable!.

  7. The local effect of octreotide on mechanical pain sensitivity is more sensitive in DA rats than DA.1U rats.

    PubMed

    Yao, Fan-Rong; Wang, Hui-Sheng; Guo, Yuan; Zhao, Yan

    2016-02-01

    A recent study by the authors indicated that major histocompatibility complex (MHC) genes are associated with the differences in basal pain sensitivity and in formalin model between Dark-Agouti (DA) and novel congenic DA.1U rats, which have the same genetic background as DA rats except for the u alleles of MHC. The objective of the present study is to investigate whether there is a difference in the pristane-induced arthritis (PIA) model and local analgesic effect of octreotide (OCT) between DA and DA.1U rats. The hindpaw mechanical withdrawal threshold (MWT) and heat withdrawal latency (HWL) were observed. The C unit firings of the tibial nerve evoked by non-noxious and noxious toe movements were recorded by electrophysiological methods in normal and PIA models in DA and DA.1U rats before and after local OCT administration. The expression of somatostatin receptor 2A (SSTR2A) was observed by immunohistochemistry. The results demonstrate that DA rats have a higher mechanical sensitivity than DA.1U rats after PIA. Local OCT administration significantly elevated MWT in DA rats under normal and PIA sate, but not in DA.1U rats. The electrophysiological experiments showed OCT significantly attenuated the firings of C units evoked by non-noxious and noxious stimulation in DA rats more than those in DA.1U rats both in normal and PIA states. In addition, the expression of SSTR2A in the dorsal horn of the spinal cord was significantly higher in DA than in DA.1U rats. All of the findings suggest a higher local analgesic effect of OCT in DA rats than DA.1U rats, which might be associated with the MHC genes. © 2016 John Wiley & Sons Australia, Ltd.

  8. 75 FR 75868 - Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 40 and DA 40F Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-07

    ... Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 40 and DA 40F Airplanes AGENCY: Federal... of the Thielert Engine Owners Group commented that the Model DA 42 has the same door design and the same unsafe condition. He recommended that the AD also apply to the Model DA 42. The FAA has discussed...

  9. Do Capacity Coupled Electric Fields Accelerate Tibial Stress Fracture Healing

    DTIC Science & Technology

    2006-12-01

    472-481, 1995 25. Gaeta M, Minutoli F, Scribano E, Ascenti G, Vinci S, Bruschetta D, Magaudda L, Blandino A: CT and MR imaging findings in athletes...1995 25. Gaeta M, Minutoli F, Scribano E, Ascenti G, Vinci S, Bruschetta D, Magaudda L, Blandino A: CT and MR imaging findings in athletes with

  10. Effect of 14-kDa and 47-kDa protein molecules of age garlic extract on peritoneal macrophages.

    PubMed

    Daneshmandi, Saeed; Hajimoradi, Monire; Ahmadabad, Hasan Namdar; Hassan, Zuhair Mohammad; Roudbary, Maryam; Ghazanfari, Tooba

    2011-03-01

    Garlic (Allium sativum), traditionally being used as a spice worldwide, has different applications and is claimed to possess beneficial effects in several health ailments such as tumor and atherosclerosis. Garlic is also an immunomodulator and its different components are responsible for different properties. The present work aimed to assess the effect of protein fractions of garlic on peritoneal macrophages. 14-kDa and 47-kDa protein fractions of garlic were purified. Mice peritoneal macrophages were lavaged and cultured in a microtiter plate and exposed to different concentrations of garlic proteins. MTT assay was performed to evaluate the viability of macrophage. The amount of nitric oxide (NO) was detected in culture supernatants of macrophages by Griess reagent and furthermore, the cytotoxicity study of culture supernatants was carried out on WEHI-164 fibrosarcoma cell line as tumor necrosis factor-α bioassay. MTT assay results for both 14-kDa and 47-kDa protein fractions of stimulated macrophages were not significant (P > 0.05). Both 14-kDa and 47-kDa fractions significantly suppressed production of NO from macrophages (P = 0.007 and P = 0.003, respectively). Cytotoxicity of macrophages' supernatant on WEHI-164 fibrosarcoma cells was not affected by garlic protein fractions (P = 0.066 for 14-kDa and P = 0.085 for 47-kDa fractions). according to our finding, 14-kDa and 47-kDa fractions of aged garlic extract are able to suppress NO production from macrophages, which can be used as a biological advantage. These molecules had no cytotoxic effect on macrophages and do not increase tumoricidal property of macrophages.

  11. Low Head, Vortex Induced Vibrations River Energy Converter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernitsas, Michael B.; Dritz, Tad

    2006-06-30

    Vortex Induced Vibrations Aquatic Clean Energy (VIVACE) is a novel, demonstrated approach to extracting energy from water currents. This invention is based on a phenomenon called Vortex Induced Vibrations (VIV), which was first observed by Leonardo da Vinci in 1504AD. He called it ‘Aeolian Tones.’ For decades, engineers have attempted to prevent this type of vibration from damaging structures, such as offshore platforms, nuclear fuel rods, cables, buildings, and bridges. The underlying concept of the VIVACE Converter is the following: Strengthen rather than spoil vortex shedding; enhance rather than suppress VIV; harness rather than mitigate VIV energy. By maximizing andmore » utilizing this unique phenomenon, VIVACE takes this “problem” and successfully transforms it into a valuable resource for mankind.« less

  12. Robust feature tracking for endoscopic pose estimation and structure recovery

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Krappe, S.; Röhl, S.; Bodenstedt, S.; Müller-Stich, B.; Dillmann, R.

    2013-03-01

    Minimally invasive surgery is a highly complex medical discipline with several difficulties for the surgeon. To alleviate these difficulties, augmented reality can be used for intraoperative assistance. For visualization, the endoscope pose must be known which can be acquired with a SLAM (Simultaneous Localization and Mapping) approach using the endoscopic images. In this paper we focus on feature tracking for SLAM in minimally invasive surgery. Robust feature tracking and minimization of false correspondences is crucial for localizing the endoscope. As sensory input we use a stereo endoscope and evaluate different feature types in a developed SLAM framework. The accuracy of the endoscope pose estimation is validated with synthetic and ex vivo data. Furthermore we test the approach with in vivo image sequences from da Vinci interventions.

  13. Evaluation Study of Pedagogical Methods and E - Learning Material via Web 2.0 for Hearing Impaired People

    NASA Astrophysics Data System (ADS)

    Vrettaros, John; Argiri, Katerina; Stavrou, Pilios; Hrissagis, Kostas; Drigas, Athanasios

    The primary goal of this paper is to study whether WEB 2.0 tools such as blogs, wikis, social networks and typical hypermedia as well as techniques such as lip - reading, video - sign language and learning activities are appropriate to use for learning purpose for deaf and hard of hearing people. In order to check the extent in which the choices mentioned above are compatible with the features of the specific group and maximize the learning results we designed an empirical study which will be presented below. The study was conducted in the context of SYNERGIA, a project of Leonardo da Vinci of Lifelong Learning Programme, in the section of MULTILATERAL PROJECTS TRANSFER OF INNOVATION, The evaluation was conducted on data that came up through questionnaire analysis.

  14. Turbulence

    NASA Astrophysics Data System (ADS)

    Frisch, Uriel

    1996-01-01

    Written five centuries after the first studies of Leonardo da Vinci and half a century after A.N. Kolmogorov's first attempt to predict the properties of flow, this textbook presents a modern account of turbulence, one of the greatest challenges in physics. "Fully developed turbulence" is ubiquitous in both cosmic and natural environments, in engineering applications and in everyday life. Elementary presentations of dynamical systems ideas, probabilistic methods (including the theory of large deviations) and fractal geometry make this a self-contained textbook. This is the first book on turbulence to use modern ideas from chaos and symmetry breaking. The book will appeal to first-year graduate students in mathematics, physics, astrophysics, geosciences and engineering, as well as professional scientists and engineers.

  15. Is there a role for robotic totally endoscopic coronary artery bypass in patients with a colostomy?

    PubMed

    Gibber, Marc; Lehr, Eric J; Kon, Zachary N; Wehman, P Brody; Griffith, Bartley P; Bonatti, Johannes

    2014-01-01

    Preoperative colostomy presents a significant risk of sternal wound complications, mediastinitis, and ostomy injury in patients requiring coronary artery bypass grafting. Less invasive procedures in coronary surgery have a potential to reduce the risk of sternal wound healing problems. Robotic totally endoscopic coronary artery bypass grafting in patients with a colostomy has not been reported. We describe a case of completely endoscopic coronary surgery using the da Vinci Si system in a patient with a transverse colostomy. Single left internal mammary artery grafting to the left anterior coronary artery was performed successfully on the beating heart. We regard this technique as the least invasive method of surgical coronary revascularization with a potential to reduce the risk of surgical site infection and mediastinitis in patients with a colostomy.

  16. Robotic phrenic nerve harvest: a feasibility study in a pig model.

    PubMed

    Porto de Melo, P; Miyamoto, H; Serradori, T; Ruggiero Mantovani, G; Selber, J; Facca, S; Xu, W-D; Santelmo, N; Liverneaux, P

    2014-10-01

    The aim of this study was to report on the feasibility of robotic phrenic nerve harvest in a pig model. A surgical robot (Da Vinci S™ system, Intuitive Surgical(®), Sunnyvale, CA) was installed with three ports on the pig's left chest. The phrenic nerve was transected distally where it enters the diaphragm. The phrenic nerve harvest was successfully performed in 45 minutes without major complications. The advantages of robotic microsurgery for phrenic nerve harvest are the motion scaling up to 5 times, elimination of physiological tremor, and free movement of joint-equipped robotic arms. Robot-assisted neurolysis may be clinically useful for harvesting the phrenic nerve for brachial plexus reconstruction. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Control of a human-powered helicopter in hover

    NASA Technical Reports Server (NTRS)

    Totah, Joseph J.; Patterson, William

    1988-01-01

    The study of a control system for the Da Vinci 2 human-powered helicopter in hovering flight is documented. This helicopter has two very large, slowly rotating rotor blades and is considered to be unstable in hover. The control system is designed to introduce stability in hover by maintaining level rotors through the use of rotor tip mounted control surfaces. A five degree of freedom kinematic model was developed to study this control system and is documented. Results of this study show that the unaugmented configuration is unstable due to the large Lock Number, and the augmented configuration is stable. The role of NASA in this study included the development and analysis of the kinematic model and control laws. Both analytical and numerical techniques were used.

  18. [Robotic surgery -- the modern surgical treatment of prostate cancer].

    PubMed

    Szabó, Ferenc János; Alexander, de la Taille

    2014-09-01

    Minimally invasive laparoscopic surgery replaces many open surgery procedures in urology due to its advantages concerning post-operative morbidity. However, the technical challenges and need of learning have limited the application of this method to the work of highly qualified surgeons. The introduction of da Vinci surgical system has offered important technical advantages compared to the laparoscopic surgical procedure. Robot-assisted radical prostatectomy became a largely accepted procedure. It has paved the way for urologists to start other, more complex operations, decreasing this way the operative morbidity. The purpose of this article is to overview the history of robotic surgery, its current and future states in the treatment of the cancer. We present our robot-assisted radical prostatectomy and the results.

  19. Remote ultrasound palpation for robotic interventions using absolute elastography.

    PubMed

    Schneider, Caitlin; Baghani, Ali; Rohling, Robert; Salcudean, Septimiu

    2012-01-01

    Although robotic surgery has addressed many of the challenges presented by minimally invasive surgery, haptic feedback and the lack of knowledge of tissue stiffness is an unsolved problem. This paper presents a system for finding the absolute elastic properties of tissue using a freehand ultrasound scanning technique, which utilizes the da Vinci Surgical robot and a custom 2D ultrasound transducer for intraoperative use. An external exciter creates shear waves in the tissue, and a local frequency estimation method computes the shear modulus. Results are reported for both phantom and in vivo models. This system can be extended to any 6 degree-of-freedom tracking method and any 2D transducer to provide real-time absolute elastic properties of tissue.

  20. Critical analysis of robotic surgery for laryngeal tumours.

    PubMed

    Esteban, Francisco; Menoyo, Alicia; Abrante, Antonio

    2014-01-01

    In recent years, transoral robotic surgery (TORS) with the Da Vinci robot has been used for the removal of laryngeal cancers with the objective to improve functional and aesthetic outcomes without worsening survival. The advantages of TORS are described in this article. However, its disadvantages, mainly high cost amongst others, do not make robotic surgery the current treatment of choice for laryngeal tumours; transoral laser surgery is superior in most cases. Major technical improvements are expected. Smaller, more ergonomic, new-generation robots better adapted to the head and neck will probably be available in the near future. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  1. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    PubMed

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  2. Error suppression and correction for quantum annealing

    NASA Astrophysics Data System (ADS)

    Lidar, Daniel

    While adiabatic quantum computing and quantum annealing enjoy a certain degree of inherent robustness against excitations and control errors, there is no escaping the need for error correction or suppression. In this talk I will give an overview of our work on the development of such error correction and suppression methods. We have experimentally tested one such method combining encoding, energy penalties and decoding, on a D-Wave Two processor, with encouraging results. Mean field theory shows that this can be explained in terms of a softening of the closing of the gap due to the energy penalty, resulting in protection against excitations that occur near the quantum critical point. Decoding recovers population from excited states and enhances the success probability of quantum annealing. Moreover, we have demonstrated that using repetition codes with increasing code distance can lower the effective temperature of the annealer. References: K.L. Pudenz, T. Albash, D.A. Lidar, ``Error corrected quantum annealing with hundreds of qubits'', Nature Commun. 5, 3243 (2014). K.L. Pudenz, T. Albash, D.A. Lidar, ``Quantum annealing correction for random Ising problems'', Phys. Rev. A. 91, 042302 (2015). S. Matsuura, H. Nishimori, T. Albash, D.A. Lidar, ``Mean Field Analysis of Quantum Annealing Correction''. arXiv:1510.07709. W. Vinci et al., in preparation.

  3. PKC phosphorylates residues in the N-terminal of the DA transporter to regulate amphetamine-induced DA efflux.

    PubMed

    Wang, Qiang; Bubula, Nancy; Brown, Jason; Wang, Yunliang; Kondev, Veronika; Vezina, Paul

    2016-05-27

    The DA transporter (DAT), a phosphoprotein, controls extracellular dopamine (DA) levels in the central nervous system through transport or reverse transport (efflux). Multiple lines of evidence support the claim that PKC significantly contributes to amphetamine-induced DA efflux. Other signaling pathways, involving CaMKII and ERK, have also been shown to regulate DAT mediated efflux. Here we assessed the contribution of putative PKC residues (S4, S7, S13) in the N-terminal of the DAT to amphetamine-induced DA efflux by transfecting DATs containing different serine to alanine (S-A) point mutations into DA pre-loaded HEK-293 cells and incubating these cells in amphetamine (2μM). The effects of a S-A mutation at the non-PKC residue S12 and a threonine to alanine (T-A) mutation at the ERK T53 residue were also assessed for comparison. WT-DATs were used as controls. In an initial experiment, we confirmed that inhibiting PKC with Go6976 (130nM) significantly reduced amphetamine-induced DA efflux. In subsequent experiments, cells transfected with the S4A, S12A, S13A, T53A and S4,7,13A mutants showed a reduction in amphetamine-induced DA efflux similar to that observed with Go6976. Interestingly, cells transfected with the S7A mutant, identified by some as a PKC-PKA residue, showed unperturbed WT-DAT levels of amphetamine-induced DA efflux. These results indicate that phosphorylation by PKC of select residues in the DAT N-terminal can regulate amphetamine-induced efflux. PKC can act either independently or in concert with other kinases such as ERK to produce this effect. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Robot-assisted laparoendoscopic single site adrenalectomy: A comparison of 3 different port platforms with 3 case reports.

    PubMed

    Kan, Hung-Cheng; Pang, See-Tong; Wu, Chun-Te; Chang, Ying-Hsu; Liu, Chung-Yi; Chuang, Cheng-Keng; Lin, Po-Hung

    2017-12-01

    Laparoscopic adrenalectomy is currently the standard of care for adrenal lesion. Minimal invasive laparoscopic surgery such as laparoendoscopic single site surgery (LESS) and natural orifice transluminal endoscopic surgery (NOTES) have been developed to improve cosmetic outcomes and reduce postoperative pain. However, there are still some problems related to instruments and port limitation during LESS surgery. Robot-assisted laparoscopic surgery may help to overcome these problems, and port platforms selection is an important issue. Three cases received robot-assisted LESS adrenalectomy due to adrenal tumor were enrolled. Blood loss, hospital stay, and analgesia injection were compared. Preoperative evaluations were done in a usual manner. Benign tumors were suspect for two patients, while metastatic tumor could not be excluded for the other patient with prior malignancy history. The pathology reports were all benign adrenal cortical adenoma after operation. Three different port platforms, Da Vinci Single-Site Surgical Platform, GelPOINT, and homemade glove port were used. Trans-peritoneal approach was used for two patients, while the other one received trans-retroperitoneal approach. The advantage and disadvantage of different port platforms were discussed. All patients underwent the operation smoothly without major complications or conversion to open surgery. Blood loss amount was small, hospital stay was short, and only one patient received one single dose of opioid analgesia injection after the surgery. The main problems of LESS are the loss of a working triangle and the limitations of the instruments. Robot-assisted LESS may help surgeons overcome part of these problems. Many different port platforms are available, and based on our initial experience, we believe that the GelPoint may be a more suitable platform, for it maintains the endo-wrist function of the Da Vinci instruments, and allows the surgeon to design the position of ports freely to minimize

  5. A comparative analysis and guide to virtual reality robotic surgical simulators.

    PubMed

    Julian, Danielle; Tanaka, Alyssa; Mattingly, Patricia; Truong, Mireille; Perez, Manuela; Smith, Roger

    2018-02-01

    Since the US Food and Drug Administration approved robotically assisted surgical devices for human surgery in 2000, the number of surgeries utilizing this innovative technology has risen. In 2015, approximately 650 000 robot-assisted procedures were performed worldwide. Surgeons must be properly trained to safely transition to using such innovative technology. Multiple virtual reality robotic simulators are now commercially available for educational and training purposes. There is a need for comparative evaluations of these simulators to aid users in selecting an appropriate device for their purposes. We conducted a comparison of the design and capabilities of all dedicated simulators of the da Vinci robot - the da Vinci Skills Simulator (dVSS), dV-Trainer (dVT), Robotic Skills Simulators (RoSS) and the RobotiX Mentor. This paper provides the base specifications of the hardware and software, with an emphasis on the training capabilities of each system. Each simulator contains a large number of training exercises for skills development: dVSS n = 40, dVT n = 65, RoSS n = 52, RobotiX Mentor n = 31. All four offer 3D visual images but use different display technologies. The dVSS leverages the real robotic surgical console to provide visualization, hand controls and foot pedals. The dVT, RoSS and RobotiX Mentor created simulated versions of all of these control systems. Each includes systems management services that allow instructors to collect, export and analyze the scores of students using the simulators. This study provides comparative information on the four simulators' functional capabilities. Each device offers unique advantages and capabilities for training robotic surgeons. Each has been the subject of validation experiments, which have been published in the literature. But those do not provide specific details on the capabilities of the simulators, which are necessary for an understanding sufficient to select the one best suited for an organization

  6. Transferability of Virtual Reality, Simulation-Based, Robotic Suturing Skills to a Live Porcine Model in Novice Surgeons: A Single-Blind Randomized Controlled Trial.

    PubMed

    Vargas, Maria V; Moawad, Gaby; Denny, Kathryn; Happ, Lindsey; Misa, Nana Yaa; Margulies, Samantha; Opoku-Anane, Jessica; Abi Khalil, Elias; Marfori, Cherie

    To assess whether a robotic simulation curriculum for novice surgeons can improve performance of a suturing task in a live porcine model. Randomized controlled trial (Canadian Task Force classification I). Academic medical center. Thirty-five medical students without robotic surgical experience. Participants were enrolled in an online session of training modules followed by an in-person orientation. Baseline performance testing on the Mimic Technologies da Vinci Surgical Simulator (dVSS) was also performed. Participants were then randomly assigned to the completion of 4 dVSS training tasks (camera clutching 1, suture sponge 1 and 2, and tubes) versus no further training. The intervention group performed each dVSS task until proficiency or up to 10 times. A final suturing task was performed on a live porcine model, which was video recorded and blindly assessed by experienced surgeons. The primary outcomes were Global Evaluative Assessment of Robotic Skills (GEARS) scores and task time. The study had 90% power to detect a mean difference of 3 points on the GEARS scale, assuming a standard deviation (SD) of 2.65, and 80% power to detect a mean difference of 3 minutes, assuming an SD of 3 minutes. There were no differences in demographics and baseline skills between the 2 groups. No significant differences in task time in minutes or GEARS scores were seen for the final suturing task between the intervention and control groups, respectively (9.2 [2.65] vs 9.9 [2.07] minutes, p = .406; and 15.37 [2.51] vs 15.25 [3.38], p = .603). The 95% confidence interval for the difference in mean task times was -2.36 to .96 minutes and for mean GEARS scores -1.91 to 2.15 points. Live suturing task performance was not improved with a proficiency-based virtual reality simulation suturing curriculum compared with standard orientation to the da Vinci robotic console in a group of novice surgeons. Published by Elsevier Inc.

  7. Effects of robotic manipulators on movements of novices and surgeons.

    PubMed

    Nisky, Ilana; Okamura, Allison M; Hsieh, Michael H

    2014-07-01

    Robot-assisted surgery is widely adopted for many procedures but has not realized its full potential to date. Based on human motor control theories, the authors hypothesized that the dynamics of the master manipulators impose challenges on the motor system of the user and may impair performance and slow down learning. Although studies have shown that robotic outcomes are correlated with the case experience of the surgeon, the relative contribution of cognitive versus motor skill is unknown. This study quantified the effects of da Vinci Si master manipulator dynamics on movements of novice users and experienced surgeons and suggests possible implications for training and robot design. In the reported study, six experienced robotic surgeons and ten novice nonmedical users performed movements under two conditions: teleoperation of a da Vinci Si Surgical system and freehand. A linear mixed model was applied to nine kinematic metrics (including endpoint error, movement time, peak speed, initial jerk, and deviation from a straight line) to assess the effects of teleoperation and expertise. To assess learning effects, t tests between the first and last movements of each type were used. All the users moved slower during teleoperation than during freehand movements (F(1,9343) = 345; p < 0.001). The experienced surgeons had smaller errors than the novices (F(1,14) = 36.8; p < 0.001). The straightness of movements depended on their direction (F(7,9343) = 117; p < 0.001). Learning effects were observed in all conditions. Novice users first learned the task and then the dynamics of the manipulator. The findings showed differences between the novices and the experienced surgeons for extremely simple point-to-point movements. The study demonstrated that manipulator dynamics affect user movements, suggesting that these dynamics could be improved in future robot designs. The authors showed the partial adaptation of novice users to the dynamics. Future studies are needed to evaluate

  8. 32 CFR 516.25 - DA Form 4.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true DA Form 4. 516.25 Section 516.25 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY AID OF CIVIL AUTHORITIES AND PUBLIC RELATIONS LITIGATION Reporting Legal Proceedings to HQDA § 516.25 DA Form 4. (a) General. The DA Form 4 (See figure C-2...

  9. Robotic-assisted minimally invasive surgery for gynecologic and urologic oncology: an evidence-based analysis.

    PubMed

    2010-01-01

    An application was received to review the evidence on the 'The Da Vinci Surgical System' for the treatment of gynecologic malignancies (e.g. endometrial and cervical cancers). Limitations to the current standard of care include the lack of trained physicians on minimally invasive surgery and limited access to minimally invasive surgery for patients. The potential benefits of 'The Da Vinci Surgical System' include improved technical manipulation and physician uptake leading to increased surgeries, and treatment and management of these cancers. The demand for robotic surgery for the treatment and management of prostate cancer has been increasing due to its alleged benefits of recovery of erectile function and urinary continence, two important factors of men's health. The potential technical benefits of robotic surgery leading to improved patient functional outcomes are surgical precision and vision. Uterine and cervical cancers represent 5.4% (4,400 of 81,700) and 1.6% (1,300 of 81,700), respectively, of incident cases of cancer among female cancers in Canada. Uterine cancer, otherwise referred to as endometrial cancer is cancer of the lining of the uterus. The most common treatment option for endometrial cancer is removing the cancer through surgery. A surgical option is the removal of the uterus and cervix through a small incision in the abdomen using a laparoscope which is referred to as total laparoscopic hysterectomy. Risk factors that increase the risk of endometrial cancer include taking estrogen replacement therapy after menopause, being obese, early age at menarche, late age at menopause, being nulliparous, having had high-dose radiation to the pelvis, and use of tamoxifen. Cervical cancer occurs at the lower narrow end of the uterus. There are more treatment options for cervical cancer compared to endometrial cancer, however total laparoscopic hysterectomy is also a treatment option. Risk factors that increase the risk for cervical cancer are multiple

  10. Beyond Donor-Acceptor (D-A) Approach: Structure-Optoelectronic Properties-Organic Photovoltaic Performance Correlation in New D-A1 -D-A2 Low-Bandgap Conjugated Polymers.

    PubMed

    Chochos, Christos L; Drakopoulou, Sofia; Katsouras, Athanasios; Squeo, Benedetta M; Sprau, Christian; Colsmann, Alexander; Gregoriou, Vasilis G; Cando, Alex-Palma; Allard, Sybille; Scherf, Ullrich; Gasparini, Nicola; Kazerouni, Negar; Ameri, Tayebeh; Brabec, Christoph J; Avgeropoulos, Apostolos

    2017-04-01

    Low-bandgap near-infrared polymers are usually synthesized using the common donor-acceptor (D-A) approach. However, recently polymer chemists are introducing more complex chemical concepts for better fine tuning of their optoelectronic properties. Usually these studies are limited to one or two polymer examples in each case study so far, though. In this study, the dependence of optoelectronic and macroscopic (device performance) properties in a series of six new D-A 1 -D-A 2 low bandgap semiconducting polymers is reported for the first time. Correlation between the chemical structure of single-component polymer films and their optoelectronic properties has been achieved in terms of absorption maxima, optical bandgap, ionization potential, and electron affinity. Preliminary organic photovoltaic results based on blends of the D-A 1 -D-A 2 polymers as the electron donor mixed with the fullerene derivative [6,6]-phenyl-C 71 -butyric acid methyl ester demonstrate power conversion efficiencies close to 4% with short-circuit current densities (J sc ) of around 11 mA cm -2 , high fill factors up to 0.70, and high open-circuit voltages (V oc s) of 0.70 V. All the devices are fabricated in an inverted architecture with the photoactive layer processed in air with doctor blade technique, showing the compatibility with roll-to-roll large-scale manufacturing processes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. The Ubiquitin Receptor DA1 Interacts with the E3 Ubiquitin Ligase DA2 to Regulate Seed and Organ Size in Arabidopsis[C][W

    PubMed Central

    Xia, Tian; Li, Na; Dumenil, Jack; Li, Jie; Kamenski, Andrei; Bevan, Michael W.; Gao, Fan; Li, Yunhai

    2013-01-01

    Seed size in higher plants is determined by the coordinated growth of the embryo, endosperm, and maternal tissue. Several factors that act maternally to regulate seed size have been identified, such as AUXIN RESPONSE FACTOR2, APETALA2, KLUH, and DA1, but the genetic and molecular mechanisms of these factors in seed size control are almost totally unknown. We previously demonstrated that the ubiquitin receptor DA1 acts synergistically with the E3 ubiquitin ligase ENHANCER1 OF DA1 (EOD1)/BIG BROTHER to regulate the final size of seeds in Arabidopsis thaliana. Here, we describe another RING-type protein with E3 ubiquitin ligase activity, encoded by DA2, which regulates seed size by restricting cell proliferation in the maternal integuments of developing seeds. The da2-1 mutant forms large seeds, while overexpression of DA2 decreases seed size of wild-type plants. Overexpression of rice (Oryza sativa) GRAIN WIDTH AND WEIGHT2, a homolog of DA2, restricts seed growth in Arabidopsis. Genetic analyses show that DA2 functions synergistically with DA1 to regulate seed size, but does so independently of EOD1. Further results reveal that DA2 interacts physically with DA1 in vitro and in vivo. Therefore, our findings define the genetic and molecular mechanisms of three ubiquitin-related proteins DA1, DA2, and EOD1 in seed size control and indicate that they are promising targets for crop improvement. PMID:24045020

  12. The feasibility of transvaginal robotic surgery in the repair of pelvic organ prolapse.

    PubMed

    Yaghnam, Ibrahim; Thomas, Dominique; Rosenblatt, Peter; Chughtai, Bilal

    2017-08-01

    Pelvic organ prolapse (POP), the descent of one or more pelvic organs, occurs in an estimated 40 to 60% of parous women. Conventional transvaginal surgery for POP has been plagued with high failure rates. The purpose was to determine the safety and feasibility of robotic transvaginal POP surgery. The da Vinci Surgical Robot, SI was used in the POP surgical procedures. There were two cadavers (aged 18 and 78 years of age; BMI 17.2 and 19.2 respectively). POP-Q scores before intervention were stage 1 for both cadavers. The visualization of anatomical landmarks and the placement of sutures at these locations were successful. Robotic transvaginal POP is a feasible option for POP surgery. Further studies are warranted to determine the role of robotic transvaginal POP repair.

  13. Virtual reality-assisted robotic surgery simulation.

    PubMed

    Albani, Justin M; Lee, David I

    2007-03-01

    For more than a decade, advancing computer technologies have allowed incorporation of virtual reality (VR) into surgical training. This has become especially important in training for laparoscopic procedures, which often are complex and leave little room for error. With the advent of robotic surgery and the development and prevalence of a commercial surgical system (da Vinci robot; Intuitive Surgical, Sunnyvale, CA), a valid VR-assisted robotic surgery simulator could minimize the steep learning curve associated with many of these complex procedures and thus enable better outcomes. To date, such simulation does not exist; however, several agencies and corporations are involved in making this dream a reality. We review the history and progress of VR simulation in surgical training, its promising applications in robotic-assisted surgery, and the remaining challenges to implementation.

  14. Identification of vortices in complex flows

    NASA Astrophysics Data System (ADS)

    Chakraborty, P.; Balachandar, S.; Adrian, R. J.

    2007-12-01

    Dating back to Leonardo da Vinci's famous sketches of vortices in turbulent flows, fluid dynamicists for over five centuries have continued to visualize and interpret complex flows in terms of motion of vortices. Nevertheless, much debate surrounds the question of how to unambiguously define vortices in complex flows. This debate has resulted in the availability of many vortex identification criteria---mathematical statements of what constitutes a vortex. Here we review the popularly used local or point- wise vortex identification criteria. Based on local flow kinematics, we describe a unified framework to interpret the similarities and differences in the usage of these criteria. We discuss the limitations on the applicability of these criteria when there is a significant component of vortex interactions. Finally, we provide guidelines for applying these criteria to geophysical flows.

  15. The extent of man from Vitruvius to Marfan.

    PubMed

    Schott, G D

    It is frequently stated that patients with Marfan's syndrome have an arm span greater than height. This implies a characteristic different from the proportions in normal adult man, in whom span and height are often thought to be equal. Such equality of span and height, which allows man to be portrayed within a square, has been a widely held concept, immortalised by Leonardo da Vinci, that dates from the Roman Vitruvius. However, in the past two hundred years, anthropometry has shown that span exceeds height in 59-78% of normal adult white men. Thus not only is the classic concept of equality of span and height generally incorrect, but also a span greater than height cannot be considered characteristic of Marfan's syndrome. Paradoxically, in some affected individuals, Vitruvian equality of height and span may occur.

  16. A Unique Instrumental Malfunction during Robotic Prostatectomy

    PubMed Central

    Park, Sung Yul; Ahn, Jenny Jin-Kyung; Jeong, Wooju; Ham, Won Sik

    2010-01-01

    Over the past decade, the introduction of robotics in the field of medicine has provided a new approach to patients requiring surgery, and both its advantages and disadvantages are currently under study by many groups worldwide. The use of robotics has especially been considered by the urological community as a treatment option in radical prostatectomy. The current case report is one in which the da Vinci Surgical System™, with fourth arm use was employed in radical prostatectomy. This case presents a unique occurrence in which a bolt of the Prograsper forcep became loose during an operation, leading to diminished device functionality and later impedance of its removal. A circumstance such as this has not previously been reported, so we introduce for other robotic surgeons our unique instrumental malfunction case during a robotic prostatectomy. PMID:20046531

  17. Paracelsus and the science of nutrition in the renaissance. On occasion of the 500th anniversary of his birth.

    PubMed

    Guggenheim, K Y

    1993-07-01

    Paracelsus (1493-1541) was a Swiss chemist and physician. As professor of medicine in Basel, he violently opposed traditional Galenic medicine and emphasized direct observation instead. His nonconformist views and rough behaviour led to his expulsion after less than a year. He led an itinerant life, practicing medicine, writing books and studying diseases of miners. Paracelcus believed in an immaterial principle, the "alchemist," that converted food into body substance. Every animal species, he believed, was endowed with its own alchemist, adapted to its needs. Paracelcus introduced chemical thinking into medicine (iatrochemistry) and nutrition. Today, he remains a controversial figure. Other Renaissance scientists (Fernel, Vesalius) criticized traditional medicine without completely rejecting it. Leonardo da Vinci developed original views on nutrition, based on his anatomical studies. His views were, however, without influence, because he did not publish.

  18. Systematic review of published studies on safety and efficacy of thoracoscopic and robot-assisted lobectomy for lung cancer.

    PubMed

    Nakamura, Hiroshige

    2014-01-01

    The safety and efficacy of thoracoscopic and robot-assisted lobectomies for primary lung cancer were reviewed in the literature. Thoracoscopic surgery is less invasive compared to thoracotomy, and it has been reported to be superior with regard to the outcome. In addition, the operability of a surgical robot (da Vinci) is favorable and supplements the disadvantages of conventional endoscopic surgery. Robot-assisted lobectomy has been reported to be comparable to thoracoscopic surgery with regard to the safety and efficacy based on analysis of perioperative results and superior with regard to the operability and length of the learning curve. However, a high cost and a long operative time are of concern. Since robot-assisted surgery has been performed only in early cases, the continuation of a comparative investigation may be necessary.

  19. Totally endoscopic sequential arterial coronary artery bypass grafting on the beating heart

    PubMed Central

    Ak, Koray; Wimmer-Greinecker, Gerhard; Dzemali, Omer; Moritz, Anton; Dogan, Selami

    2007-01-01

    A 50-year-old man was referred to the Department of Thoracic and Cardiovascular Surgery at the Johann Wolfgang-Goethe University (Frankfurt, Germany) with angina on exertion. An evaluation revealed critical stenosis involving the proximal portion of the left anterior descending artery and the first diagonal branch. The patient underwent successful sequential grafting of the left internal mammary artery to the left anterior descending artery and the diagonal branch using a totally endoscopic coronary artery bypass grafting technique on the beating heart with a new version of the da Vinci Surgical System (Intuitive Surgical, USA). To the authors’ knowledge, this is the first report in literature to describe sequential arterial off-pump grafting of two anterior wall target vessels using a totally endoscopic technique on the beating heart. PMID:17440646

  20. PSYCHOANALYSIS AND THE ARTS: THE SLIPPERY GROUND OF APPLIED ANALYSIS.

    PubMed

    Abella, Adela

    2016-01-01

    The ways in which today's psychoanalysts approach art closely follow the avenues opened by Freud a hundred years ago. Drawing mainly on Freud's studies on Jensen's Gradiva (1907) and on Leonardo da Vinci (1910a), the author examines the main paradigms he used in discussing artistic activity, including his doubts and hesitations. Present-day approaches to art are then examined via a discussion of the advantages and pitfalls of psychobiography, of the case study, and of textual approaches. The author makes a case for the type of interdisciplinary dialogue in which the goal is to establish a cross-fertilization between psychoanalysis and other fields of knowledge while striving to avoid hypersaturation of a work of art in order to foster expansion of the mind. © 2016 The Psychoanalytic Quarterly, Inc.