Grant, Robert M; Mannheimer, Sharon; Hughes, James P; Hirsch-Moverman, Yael; Loquere, Avelino; Chitwarakorn, Anupong; Curlin, Marcel E; Li, Maoji; Amico, K Rivet; Hendrix, Craig W; Anderson, Peter L; Dye, Bonnie J; Marzinke, Mark A; Piwowar-Manning, Estelle; McKinstry, Laura; Elharrar, Vanessa; Stirratt, Michael; Rooney, James F; Eshleman, Susan H; McNicholl, Janet M; van Griensven, Frits; Holtz, Timothy H
2018-05-17
Nondaily dosing of oral preexposure prophylaxis (PrEP) may provide equivalent coverage of sex events compared with daily dosing. At-risk men and transgender women who have sex with men were randomly assigned to 1 of 3 dosing regimens: 1 tablet daily, 1 tablet twice weekly with a postsex dose (time-driven), or 1 tablet before and after sex (event-driven), and were followed for coverage of sex events with pre- and postsex dosing measured by weekly self-report, drug concentrations, and electronic drug monitoring. From July 2012 to May 2014, 357 participants were randomized. In Bangkok, the coverage of sex events was 85% for the daily arm compared with 84% for the time-driven arm (P = .79) and 74% for the event-driven arm (P = .02). In Harlem, coverage was 66%, 47% (P = .01), and 52% (P = .01) for these groups. In Bangkok, PrEP medication concentrations in blood were consistent with use of ≥2 tablets per week in >95% of visits when sex was reported in the prior week, while in Harlem, such medication concentrations occurred in 48.5% in the daily arm, 30.9% in the time-driven arm, and 16.7% in the event-driven arm (P < .0001). Creatinine elevations were more common in the daily arm (P = .050), although they were not dose limiting. Daily dosing recommendations increased coverage and protective drug concentrations in the Harlem cohort, while daily and nondaily regimens led to comparably favorable outcomes in Bangkok, where participants had higher levels of education and employment. NCT01327651.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, T; Wang, L; Galloway, T
Purpose: Head and Neck cancer treatment with IMRT/VMAT has two choices: split-filed IMRT(SFI), in which the LAN is treated with a separate anterior field and the extended whole-field IMRT(WFI) in which LAN is included with the IMRT/VMAT field. This study shows that under the same dose limit criteria, choosing the technique becomes a critical issue if daily localization and immobilization altered the dose distribution. Methods: Nine common head-and-neck cancer cases were chosen to illustrate how the daily localization and immobilization uncertainties affect to choose between SFI and WFI. Both SFI and WFI at upper target coverage were generated with VMAT.more » For each case, the same planning criteria were applied to the target and critical structures; therefore, similar target coverage and dose falloff can be observed in both techniques. Thirty days of kV cone beam CT(CBCT) images on each case were also delineated with contralateral and ipsilateral target as well as larynx as critical structure. About 300 CBCT images with daily delivered doses were analyzed and compared in a form of dose-volume histograms. Results: While both plans for SFI and WFI with VMAT planning utilized and meet the criteria of D95>prescription dose and for not-involved larynx with mean dose <35Gy and V55<10%, the daily localization and immobilization has a great contribution to the resulted dose delivery. With WFI, the better daily contralateral and ipsilateral neck target coverage can reflect a simpler or shorter localization; however, a much superior avoidance (WFI: mean dose a 42.5Gy; SFI: mean dose a 18.9Gy) of the non-involved larynx from the SFI is preferred. Conclusion: Dosimetrically, SFI and WFI are equally well for head and Neck cancer treatment with VMAT technique; however, if considering the contribution of daily localization(CBCT) method uncertainties, SFI is better with sparing non-involved larynx and WFI has better target coverage.« less
SU-C-202-05: Pilot Study of Online Treatment Evaluation and Adaptive Re-Planning for Laryngeal SBRT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, W; Henry Ford Health System, Detroit, MI; Liu, C
Purpose: We have instigated a phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for advanced-stage laryngeal cancer. We conducted this pilot dosimetric study to confirm the potential utility of online adaptive re-planning to preserve treatment quality. Methods: Ten cases of larynx cancer were evaluated. Baseline and daily SBRT treatment plans were generated per trial protocol. Daily volumetric images were acquired prior to every fraction of treatment. Reference simulation CT images were deformably registered to daily volumetric images using Eclipse. Planning contours were then deformably propagated to daily images. Reference SBRT plans were directly copied to calculate delivered dose distributionsmore » on deformed reference CT images. In-house software platform has been developed to calculate cumulative dose over a course of treatment in four steps: 1) deforming delivered dose grid to reference CT images using deformation information exported from Eclipse; 2) generating tetrahedrons using deformed dose grid as vertices; 3) resampling dose to a high resolution within every tetrahedron; 4) calculating dose-volume histograms. Our inhouse software was benchmarked with a commercial software, Mirada. Results: In all ten cases including 49 fractions of treatments, delivered daily doses were completely evaluated and treatment could be re-planned within 10 minutes. Prescription dose coverage of PTV was less than intended in 53% of fractions of treatment (mean: 94%, range: 84%–98%) while minimum coverage of CTV and GTV was 94% and 97%, respectively. Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. Conclusion: Although GTV and CTV coverage is preserved by in-room 3D image guidance of larynx SBRT, PTV coverage can vary significantly from intended plans. Online adaptive treatment evaluation and re-planning is potentially necessary and our procedure is clinically applicable to fully preserve treatment quality. This project is supported by CPRIT Individual Investigator Research Award RP150386.« less
SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, R; Sun, B; Zhao, T
Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculatedmore » on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.« less
van de Schoot, Agustinus J A J; de Boer, Peter; Visser, Jorrit; Stalpers, Lukas J A; Rasch, Coen R N; Bel, Arjan
2017-05-01
Radiation therapy (RT) using a daily plan selection adaptive strategy can be applied to account for interfraction organ motion while limiting organ at risk dose. The aim of this study was to quantify the dosimetric consequences of daily plan selection compared with non-adaptive RT in cervical cancer. Ten consecutive patients who received pelvic irradiation, planning CTs (full and empty bladder), weekly post-fraction CTs and pre-fraction CBCTs were included. Non-adaptive plans were generated based on the PTV defined using the full bladder planning CT. For the adaptive strategy, multiple PTVs were created based on both planning CTs by ITVs of the primary CTVs (i.e., GTV, cervix, corpus-uterus and upper part of the vagina) and corresponding library plans were generated. Daily CBCTs were rigidly aligned to the full bladder planning CT for plan selection. For daily plan recalculation, selected CTs based on initial similarity were deformably registered to CBCTs. Differences in daily target coverage (D 98% > 95%) and in V 0.5Gy , V 1.5Gy , V 2Gy , D 50% and D 2% for rectum, bladder and bowel were assessed. Non-adaptive RT showed inadequate primary CTV coverage in 17% of the daily fractions. Plan selection compensated for anatomical changes and improved primary CTV coverage significantly (p < 0.01) to 98%. Compared with non-adaptive RT, plan selection decreased the fraction dose to rectum and bowel indicated by significant (p < 0.01) improvements for daily V 0.5Gy , V 1.5Gy , V 2Gy , D 50% and D 2% . However, daily plan selection significantly increased the bladder V 1.5Gy , V 2Gy , D 50% and D 2% . In cervical cancer RT, a non-adaptive strategy led to inadequate target coverage for individual patients. Daily plan selection corrected for day-to-day anatomical variations and resulted in adequate target coverage in all fractions. The dose to bowel and rectum was decreased significantly when applying adaptive RT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moriya, S; National Cancer Center, Kashiwa, Chiba; Tachibana, H
Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilionmore » LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported by Japan Agency for Medical Research and Development (AMED).« less
Lutkenhaus, Lotte J; Visser, Jorrit; de Jong, Rianne; Hulshof, Maarten C C M; Bel, Arjan
2015-07-01
To account for variable bladder size during bladder cancer radiotherapy, a daily plan selection strategy was implemented. The aim of this study was to calculate the actually delivered dose using an adaptive strategy, compared to a non-adaptive approach. Ten patients were treated to the bladder and lymph nodes with an adaptive full bladder strategy. Interpolated delineations of bladder and tumor on a full and empty bladder CT scan resulted in five PTVs for which VMAT plans were created. Daily cone beam CT (CBCT) scans were used for plan selection. Bowel, rectum and target volumes were delineated on these CBCTs, and delivered dose for these was calculated using both the adaptive plan, and a non-adaptive plan. Target coverage for lymph nodes improved using an adaptive strategy. The full bladder strategy spared the healthy part of the bladder from a high dose. Average bowel cavity V30Gy and V40Gy significantly reduced with 60 and 69ml, respectively (p<0.01). Other parameters for bowel and rectum remained unchanged. Daily plan selection compared to a non-adaptive strategy yielded similar bladder coverage and improved coverage for lymph nodes, with a significant reduction in bowel cavity V30Gy and V40Gy only, while other sparing was limited. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Choi, Sung Eun; Brandeau, Margaret L; Bendavid, Eran
2017-10-06
Malaria is a leading cause of morbidity and mortality among HIV-infected pregnant women in sub-Saharan Africa: at least 1 million pregnancies among HIV-infected women are complicated by co-infection with malaria annually, leading to increased risk of premature delivery, severe anaemia, delivery of low birth weight infants, and maternal death. Current guidelines recommend either daily cotrimoxazole (CTX) or intermittent preventive treatment with sulfadoxine-pyrimethamine (IPTp-SP) for HIV-infected pregnant women to prevent malaria and its complications. The cost-effectiveness of CTX compared to IPTp-SP among HIV-infected pregnant women was assessed. A microsimulation model of malaria and HIV among pregnant women in five malaria-endemic countries in sub-Saharan Africa was constructed. Four strategies were compared: (1) 2-dose IPTp-SP at current IPTp-SP coverage of the country ("2-IPT Low"); (2) 3-dose IPTp-SP at current coverage ("3-IPT Low"); (3) 3-dose IPTp-SP at the same coverage as antiretroviral therapy (ART) in the country ("3-IPT High"); and (4) daily CTX at ART coverage. Outcomes measured include maternal malaria, anaemia, low birth weight (LBW), and disability-adjusted life years (DALYs). Sensitivity analyses assessed the effect of adherence to CTX. Compared with the 2-IPT Low Strategy, women receiving CTX had 22.5% fewer LBW infants (95% CI 22.3-22.7), 13.5% fewer anaemia cases (95% CI 13.4-13.5), and 13.6% fewer maternal malaria cases (95% CI 13.6-13.7). In all simulated countries, CTX was the preferred strategy, with incremental cost-effectiveness ratios ranging from cost-saving to $3.9 per DALY averted from a societal perspective. CTX was less effective than the 3-IPT High Strategy when more than 18% of women stopped taking CTX during the pregnancy. In malarious regions of sub-Saharan Africa, daily CTX for HIV-infected pregnant women regardless of CD4 cell count is cost-effective compared with 3-dose IPTp-SP as long as more than 82% of women adhere to daily dosing.
Maeda, Yoshikazu; Sato, Yoshitaka; Minami, Hiroki; Yasukawa, Yutaka; Yamamoto, Kazutaka; Tamamura, Hiroyasu; Shibata, Satoshi; Bou, Sayuri; Sasaki, Makoto; Tameshige, Yuji; Kume, Kyo; Ooto, Hiroshi; Kasahara, Shigeru; Shimizu, Yasuhiro; Saga, Yusuke; Omoya, Akira; Saitou, Makoto
2018-05-01
To evaluate the effectiveness of CT image-guided proton radiotherapy for prostate cancer by analyzing the positioning uncertainty and assessing daily dose change due to anatomical variations. Patients with prostate cancer were treated by opposed lateral proton beams based on a passive scattering method using an in-room CT image-guided system. The system employs a single couch for both CT scanning and beam delivery. The patient was positioned by matching the boundary between the prostate and the rectum's anterior region identified in the CT images to the corresponding boundary in the simulator images after bone matching. We acquired orthogonal kV x-ray images after couch movement and confirmed the body position by referring to the bony structure prior to treatment. In offline analyses, we contoured the targeted anatomical structures on 375 sets of daily in-room CT images for 10 patients. The uncertainty of the image-matching procedure was evaluated using the prostate contours and actual couch corrections. We also performed dose calculations using the same set of CT images, and evaluated daily change of dose-volume histograms (DVHs) to compare the effectiveness of the treatment using prostate matching to the bone-matching procedure. The isocenter shifts by prostate matching after bone matching were 0.5 ± 1.8 and -0.8 ± 2.6 mm along the superior-inferior (SI) and anterior-posterior (AP) directions, respectively. The body movement errors (σ) after couch movement were 0.7, 0.5, and 0.3 mm along the lateral, SI and AP direction, respectively, for 30 patients. The estimated errors (σ) in the prostate matching were 1.0 and 1.3 mm, and, in conjunction with the movement errors, the total positioning uncertainty was estimated to be 1.0 and 1.4 mm along the SI and AP directions, respectively. Daily DVH analyses showed that in the prostate matching, 98.7% and 86.1% of the total 375 irradiations maintained a dose condition of V 95% > 95% for the prostate and a dose constraint of V 77% < 18% for the rectum, whereas 90.4% and 66.1% of the total irradiations did so when bone matching was used. The dose constraint of the rectum and dose coverage of the prostate were better maintained by prostate matching than bone matching (P < 0.001). The daily variation in the dose to the seminal vesicles (SVs) was large, and only 40% of the total irradiations maintained the initial planned values of V 95% for high-risk treatment. Nevertheless, the deviations from the original value were -4 ± 7% and -5 ± 11% in the prostate and bone matching, respectively, and a better dose coverage of the SV was achieved by the prostate matching. The correction of repositioning along the AP and SI direction from conventional bone matching in CT image-guided proton therapy was found to be effective to maintain the dose constraint of the rectum and the dose coverage of the prostate. This work indicated that prostate cancer treatment by prostate matching using CT image guidance may be effective to reduce the rectal complications and achieve better tumor control of the prostate. However, an adaptive approach is desirable to maintain better dose coverage of the SVs. © 2018 American Association of Physicists in Medicine.
Mirabile, Aurora; Celio, Luigi; Magni, Michele; Bonizzoni, Erminio; Gianni, Alessandro Massimo; Di Nicola, Massimo
2014-12-01
Efficacy of intermittent palonosetron dosing in patients undergoing multiple-day, high-dose chemotherapy (HDC) was investigated. Fifty-eight patients received palonosetron (0.25 mg intravenous [iv.]) every other day plus daily dexamethasone (8 mg iv. twice daily) dosing. The primary end point was complete control (CC; no emesis, no rescue anti-emetics, and no more than mild nausea) in the overall acute-period (until 24 h after chemotherapy completion). Acute-period CC occurred in 81% and 50% of patients receiving palonosetron and ondansetron (historical control cohort), respectively. Palonosetron (odds ratio [OR]: 4.37; p = 0.001) and a longer duration of HDC regimen (OR: 3.47; p = 0.011) independently predicted a better anti-emetic outcome. Palonosetron every other day plus daily dexamethasone is an effective anti-emetic coverage in patients undergoing HDC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Y; Li, T; Yin, F
2015-06-15
Purpose: To investigate the choice of fixed margin or online adaptation when treating intermediate-risk prostate cancer including seminal vesicles (SV) using stereotactic body radiation therapy (SBRT). Methods: 9 prostate SBRT patients were retrospectively studied. All patients were implanted with fiducial markers in the prostate for daily localization and verification. Each patient had 5 pairs of pre-treatment and post-treatment cone-beam CT (CBCT) per protocol. SVs were contoured on planning CT and all CBCTs by one attending physician. Simultaneous integral boost (SIB) IMRT plans were developed to deliver 25Gy/5fx to the SV while delivering 37Gy/5fx to the prostate. A 3mm isotropic marginmore » was added to the prostate while a 5 mm isotropic margin was used for the SV. The planning CT was registered to daily pre-treatment and post-treatment CBCT based on fiducial markers in the prostate to mimic online prostate localization; and the SV on daily CBCT was transferred to the CT structure set after the prostates were aligned. Daily pre-treatment and post-treatment SV dose coverage and the organ-at-risk (OAR) sparing were evaluated for the SIB regimen. At least 95% of the SV need to receive the prescription dose (5Gy per fraction). Results: For the total of 90 daily SVs analyzed (ten CBCTs for each of nine patients), only 45 daily SVs (50%) were able to meet the coverage that 95% of the SV received 25Gy. The OAR sparing performance was acceptable for most of the dosimetric constraints in low-risk prostate SBRT protocol with only two exceptions in bladder V100 (cc). Conclusion: A fixed 5mm margin for SV is not sufficient to provide consistent daily dose coverage due to SV’s substantial inter- and intra-fractional motion relative to the prostate. This finding calls for innovative strategies in margin design as well as online treatment adaptation. This work is partially supported a master research grant from Varian Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Zhang, J; Qin, A
2016-06-15
Purpose: To evaluate the potential benefits of robust optimization in intensity modulated proton therapy(IMPT) treatment planning to account for inter-fractional variation for Head Neck Cancer(HNC). Methods: One patient with bilateral HNC previous treated at our institution was used in this study. Ten daily CBCTs were selected. The CT numbers of the CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration. The planning target volumes(PTVs) were defined by a 3mm expansion from clinical target volumes(CTVs). The prescription was 70Gy, 54Gy to CTV1, CTV2, and PTV1, PTV2 for robust optimized(RO) and conventionally optimized(CO) plans respectively. Bothmore » techniques were generated by RayStation with the same beam angles: two anterior oblique and two posterior oblique angles. The similar dose constraints were used to achieve 99% of CTV1 received 100% prescription dose while kept the hotspots less than 110% of the prescription. In order to evaluate the dosimetric result through the course of treatment, the contours were deformed from simulation CT to daily CBCTs, modified, and approved by a radiation oncologist. The initial plan on the simulation CT was re-replayed on the daily CBCTs followed the bony alignment. The target coverage was evaluated using the daily doses and the cumulative dose. Results: Eight of 10 daily deliveries with using RO plan achieved at least 95% prescription dose to CTV1 and CTV2, while still kept maximum hotspot less than 112% of prescription compared with only one of 10 for the CO plan to achieve the same standards. For the cumulative doses, the target coverage for both RO and CO plans was quite similar, which was due to the compensation of cold and hot spots. Conclusion: Robust optimization can be effectively applied to compensate for target dose deficit caused by inter-fractional target geometric variation in IMPT treatment planning.« less
Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri
2012-01-01
To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.
Dosimetric benefit of adaptive re-planning in pancreatic cancer stereotactic body radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Yongbao; Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA; Department of Radiation Oncology, University of California San Diego, La Jolla, CA
Stereotactic body radiotherapy (SBRT) shows promise in unresectable pancreatic cancer, though this treatment modality has high rates of normal tissue toxicity. This study explores the dosimetric utility of daily adaptive re-planning with pancreas SBRT. We used a previously developed supercomputing online re-planning environment (SCORE) to re-plan 10 patients with pancreas SBRT. Tumor and normal tissue contours were deformed from treatment planning computed tomographies (CTs) and transferred to daily cone-beam CT (CBCT) scans before re-optimizing each daily treatment plan. We compared the intended radiation dose, the actual radiation dose, and the optimized radiation dose for the pancreas tumor planning target volumemore » (PTV) and the duodenum. Treatment re-optimization improved coverage of the PTV and reduced dose to the duodenum. Within the PTV, the actual hot spot (volume receiving 110% of the prescription dose) decreased from 4.5% to 0.5% after daily adaptive re-planning. Within the duodenum, the volume receiving the prescription dose decreased from 0.9% to 0.3% after re-planning. It is noteworthy that variation in the amount of air within a patient's stomach substantially changed dose to the PTV. Adaptive re-planning with pancreas SBRT has the ability to improve dose to the tumor and decrease dose to the nearby duodenum, thereby reducing the risk of toxicity.« less
Wallender, Erika; Vucicevic, Katarina; Jagannathan, Prasanna; Huang, Liusheng; Natureeba, Paul; Kakuru, Abel; Muhindo, Mary; Nakalembe, Mirium; Havlir, Diane; Kamya, Moses; Aweeka, Francesca; Dorsey, Grant; Rosenthal, Philip J; Savic, Radojka M
2018-03-05
A monthly treatment course of dihydroartemisinin-piperaquine (DHA-PQ) effectively prevents malaria during pregnancy. However, a drug-drug interaction pharmacokinetic (PK) study found that pregnant human immunodeficiency virus (HIV)-infected women receiving efavirenz-based antiretroviral therapy (ART) had markedly reduced piperaquine (PQ) exposure. This suggests the need for alternative DHA-PQ chemoprevention regimens in this population. Eighty-three HIV-infected pregnant women who received monthly DHA-PQ and efavirenz contributed longitudinal PK and corrected QT interval (QTc) (n = 25) data. Population PK and PK-QTc models for PQ were developed to consider the benefits (protective PQ coverage) and risks (QTc prolongation) of alternative DHA-PQ chemoprevention regimens. Protective PQ coverage was defined as maintaining a concentration >10 ng/mL for >95% of the chemoprevention period. PQ clearance was 4540 L/day. With monthly DHA-PQ (2880 mg PQ), <1% of women achieved defined protective PQ coverage. Weekly (960 mg PQ) or low-dose daily (320 or 160 mg PQ) regimens achieved protective PQ coverage for 34% and >96% of women, respectively. All regimens were safe, with ≤2% of women predicted to have ≥30 msec QTc increase. For HIV-infected pregnant women receiving efavirenz, low daily DHA-PQ dosing was predicted to improve protection against parasitemia and reduce risk of toxicity compared to monthly dosing. NCT02282293. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Jacobs, Michael R
2005-06-01
Acute bacterial respiratory tract infections cause a great deal of human morbidity and mortality. Treatment guidelines for these infections include macrolides, doxycycline, beta-lactams and beta-lactam/beta-lactamase inhibitor combinations such as amoxicillin/clavulanic acid to provide coverage for the common respiratory pathogens, including penicillin and macrolide nonsusceptible Streptococcus pneumoniae, as well as beta-lactamase-producing Haemophilus influenzae and Moraxella catarrhalis. In response to recent guidelines recommending higher dose amoxicillin to extend coverage to a higher percentage of S. pneumoniae, a new formulation of amoxicillin/clavulanic acid was developed. This formulation includes a higher amoxicillin dose, with part of the amoxicillin dose being in an extended release formulation, without increasing the clavulanate dose, for twice-daily oral treatment of these infections. Clinical studies of community-acquired pneumonia and acute rhinosinusitis have shown that the new formulation is well tolerated and highly efficacious, with clinical outcomes equivalent to comparators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, S; Chen, S; Zhang, B
Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported alongmore » with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freund, D; Ding, X; Zhang, J
Purpose: In prostate proton radiotherapy, three fiducial markers are used for patient daily alignment. However fiducial alignment can change beamline heterogeneity in proton therapy. The purpose of this study is to determine the difference in fiducial and boney anatomy alignment for patient treatment. Methods and materials: Prostate cancer patients who received proton treatment were included in this study. 3 fiducial markers were implanted before the initial CT. All the patients were re-CT’d every 2 weeks to check the fiducial marker position reproducibility as well as dosimetric consistence of target coverage. In geometry study, re-CT were fused to the initial CTmore » base on the boney anatomy and the average fiducial marker displacement was measured the centers of the fiducials. Dosimetrically, the initial plan was recalculated directly to re-CT image set based on the boney alignment and fiducial alignment to determine the difference from daily treatment. Prostate coverage and hotspots were evaluated using the dose to 98% of the CTV (D98) and dose to 2% (D2), respectively. Results: The shift from the initial 6 patient CT image sets resulted in an average change in the fiducial location of 5.70 +/− 3 mm. Dosimetric comparison from a single patient revealed that differences from the planned dose resulted from both boney and fiducial alignment. Planned clinical treatment volume coverage resulted in a D98 of 70.44Gy and D2 of 70.84Gy compared to a D98 of 70.13Gy and D2 70.94Gy for boney alignment and a D98 of 70.08Gy and D2 71.18Gy for fiducial alignment respectively. Conclusion: This study demonstrates that with boney anatomy alignment there is little change to CTV coverage and only slightly worse CTV coverage and hotspot production with fiducial alignment. An increase patient cohort and further investigation is necessary to determine the whether boney alignment can help better control dose heterogeneity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, S; Shang, Q; Godley, A
Purpose: To calculate the delivered dose for head and neck SBRT patients using pre-treatment images. This delivered dose was then used to determine the viability of 2.5 mm margins. Methods: Daily cone beam CTs (CBCTs) were collected for 20 patients along with a planning CT, planned dose, and planning structures. The day 1 CBCT was aligned to the planning CT using the treatment shifts (six degrees of freedom) and then the dose and contours were transferred to the CBCT. The day 1 CBCT becomes the reference image for days 2–5. The day 2–5 CBCTs were also aligned to the planningmore » CT using the treatment shifts given and the dose transferred. The day 2–5 CBCTs were then deformably registered to the day 1 CBCT. The doses delivered on days 2–5 were then deformed to the day 1 CBCT where they could be accumulated. This was achieved with MIM 6.5.1 (MIM Software, Cleveland OH). The accumulated doses for the 20 patients were evaluated against the planned doses using the initial planning criteria as points of comparison. Results: The delivered CTV dose conformed to the planned 98.6% coverage, with an average decrease of 2.6% between planned and delivered coverage. This implies the 2.5 mm margin was sufficient. Larger CTVs correlated to smaller differences between planned and delivered coverage. Delivered dose to critical structures including the spinal cord, mandible, brain, brainstem, and larynx was acceptable, with differences between planned and delivered max dose <5% on average. Similarly for the parotid glands, globes, cochlear, optic nerve, lens, and submandibular glands, differences between planned and delivered doses were generally <5%. Conclusion: The 2.5 mm margin provided acceptable CTV coverage, adequately accounting for setup errors. Organ at risk sparing was also satisfactory. Small tumor volumes (<20 cc) may require a larger margin to treat effectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, Faisal; Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA; Sarkar, Vikren
Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipsemore » treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horst, A van der; Houweling, A C; Bijveld, M M C
2015-06-15
Purpose: Pancreatic tumors show large interfractional position variations. In addition, changes in gastrointestinal air volume and body contour take place during treatment. We aim to investigate the robustness of the clinical treatment plans by quantifying the dosimetric effects of these anatomical changes. Methods: Calculations were performed for up to now 3 pancreatic cancer patients who had intratumoral fiducials for daily CBCT-based positioning during their 3-week treatment. For each patient, deformable image registration of the planning CT was used to assign Hounsfield Units to each of the 13—15 CBCTs; air volumes and body contour were copied from CBCT. The clinical treatmentmore » plan was used (CTV-PTV margin = 10 mm; 36Gy; 10MV; 1 arc VMAT). Fraction dose distributions were calculated and accumulated. The V95% of the clinical target volume (CTV) and planning target volume (PTV) were analyzed, as well as the dose to stomach, duodenum and liver. Dose accumulation was done for patient positioning based on the fiducials (as clinically used) as well as for positioning based on bony anatomy. Results: For all three patients, the V95% of the CTV remained 100%, for both fiducial- and bony anatomy-based positioning. For fiducial-based positioning, dose to duodenum en stomach showed no discernable differences with planned dose. For bony anatomy-based positioning, the PTV V95% of the patient with the largest systematic difference in tumor position (patient 1) decreased to 85%; the liver Dmax increased from 33.5Gy (planned) to 35.5Gy. Conclusion: When using intratumoral fiducials, CTV dose coverage was only mildly affected by the daily anatomical changes. When using bony anatomy for patient positioning, we found a decline in PTV dose coverage due to the interfractional tumor position variations. Photon irradiation treatment plans for pancreatic tumors are robust to variations in body contour and gastrointestinal gas, but the use of fiducial-based daily position verification is imperative. This work was supported by the foundation Bergh in het Zadel through the Dutch Cancer Society (KWF Kankerbestrijding) project No. UVA 2011-5271.« less
Henke, Lauren; Kashani, Rojano; Robinson, Clifford; Curcuru, Austen; DeWees, Todd; Bradley, Jeffrey; Green, Olga; Michalski, Jeff; Mutic, Sasa; Parikh, Parag; Olsen, Jeffrey
2018-03-01
SBRT is used to treat oligometastatic or unresectable primary abdominal malignancies, although ablative dose delivery is limited by proximity of organs-at-risk (OAR). Stereotactic, magnetic resonance (MR)-guided online-adaptive radiotherapy (SMART) may improve SBRT's therapeutic ratio. This prospective Phase I trial assessed feasibility and potential advantages of SMART to treat abdominal malignancies. Twenty patients with oligometastatic or unresectable primary liver (n = 10) and non-liver (n = 10) abdominal malignancies underwent SMART. Initial plans prescribed 50 Gy/5 fractions (BED 100 Gy) with goal 95% PTV coverage by 95% of prescription, subject to hard OAR constraints. Daily real-time online-adaptive plans were created as needed, based on daily setup MR-image-set tumor/OAR "anatomy-of-the-day" to preserve hard OAR constraints, escalate PTV dose, or both. Treatment times, patient outcomes, and dosimetric comparisons between initial and adaptive plans were prospectively recorded. Online adaptive plans were created at time of treatment for 81/97 fractions, due to initial plan violation of OAR constraints (61/97) or observed opportunity for PTV dose escalation (20/97). Plan adaptation increased PTV coverage in 64/97 fractions. Zero Grade ≥ 3 acute (<6 months) treatment-related toxicities were observed. SMART is clinically deliverable and safe, allowing PTV dose escalation and/or simultaneous OAR sparing compared to non-adaptive abdominal SBRT. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Kardas, Przemyslaw
2007-01-01
Background A randomized, controlled trial was conducted in an outpatient setting to examine the effect of beta-blocker dosing frequency on patient compliance, clinical outcome, and health-related quality of life in patients with stable angina pectoris. Methods One hundred and twelve beta-blockers-naive outpatients with stable angina pectoris were randomized to receive betaxolol, 20 mg once daily or metoprolol tartrate, 50 mg twice daily for 8 weeks. The principal outcome measure was overall compliance measured electronically, whereas secondary outcome measures were drug effectiveness and health-related quality of life. Results The overall compliance was 86.5 ± 21.3% in the betaxolol group versus 76.1 ± 26.3% in the metoprolol group (p < 0.01), and the correct number of doses was taken on 84.4 ± 21.6% and 64.0 ± 31.7% of treatment days, respectively (p < 0.0001). The percentage of missed doses was 14.5 ± 21.5% in the once-daily group and 24.8 ± 26.4% in the twice-daily group (p < 0.01). The percentage of doses taken in the correct time window (58.6% vs 42.0%, p = 0.01), correct interdose intervals (77.4% v 53.1%, p < 0.0001), and therapeutic coverage (85.6% vs 73.7%, p < 0.001) were significantly higher in the once-daily group. Both studied drugs had similar antianginal effectiveness. Health-related quality of life improved in both groups, but this increase was more pronounced in the betaxolol arm in some dimensions. Conclusions The study demonstrates that patient compliance with once-daily betaxolol is significantly better than with twice daily metoprolol. Similarly, this treatment provides better quality of life. These results demonstrate possible therapeutic advantages of once-daily over twice-daily beta-blockers in the treatment of stable angina pectoris. PMID:17580734
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trofimov, A; Carpenter, K; Shih, HA
Purpose: To quantify daily set-up variations in fractionated proton therapy of ocular melanomas, and to assess the effect on the fidelity of delivered distribution to the plan. Methods: In a typical five-fraction course, daily set-up is achieved by matching the position of fiducial markers in orthogonal radiographs to the images generated by treatment planning program. A patient maintains the required gaze direction voluntarily, without the aid of fixation devices. Confirmation radiographs are acquired to assess intrafractional changes. For this study, daily radiographs were analyzed to determine the daily iso-center position and apparent gaze direction, which were then transferred to themore » planning system to calculate the dose delivered in individual fractions, and accumulated dose for the entire course. Dose-volume metrics were compared between the planned and accumulated distributions for the tumor and organs at risk, for representative cases that varied by location within the ocular globe. Results: The analysis of the first set of cases (3 posterior, 3 transequatorial and 4 anterior tumors) revealed varying dose deviation patterns, depending on the tumor location. For anterior and posterior tumors, the largest dose increases were observed in the lens and ciliary body, while for the equatorial tumors, macula, optic nerve and disk, were most often affected. The iso-center position error was below 1.3 mm (95%-confidence interval), and the standard deviation of daily polar and azimuthal gaze set-up were 1.5 and 3 degrees, respectively. Conclusion: We quantified interfractional and intrafractional set-up variation, and estimated their effect on the delivered dose for representative cases. Current safety margins are sufficient to maintain the target coverage, however, the dose delivered to critical structures often deviates from the plan. The ongoing analysis will further explore the patterns of dose deviation, and may help to identify particular treatment scenarios which are at a higher risk for such deviations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guerreiro, F; Janssens, G; Seravalli, E
Purpose: To investigate the dosimetric impact of daily changes in patient’s diameter, due to weight gain/loss and air in the bowel, based on CBCT information during radiotherapy treatment of pediatric abdominal tumors. Methods: 10 pediatric patients with neuroblastoma (n=6) and Wilms’ (n=4) tumors were included. Available CBCTs were affinely registered to the planning CT for daily set-up variations corrections. A density override approach assigning air-density to the random air pockets and water-density to the remaining anatomy was used to determine the CBCT and CT dose. Clinical VMAT plans, with a PTV prescribed dose ranging between (14.4- 36) Gy, were re-optimizedmore » on the density override CT and re-calculated on each CBCT. Dose-volume statistics of the PTV and kidneys, delineated on each CBCT, were used to compare the daily and cumulative CBCT dose with the reference CT dose. Results: The average patient diameter variation was (0.5 ± 0.7) cm (maximum daily difference of 2.3 cm). The average PTV mean dose difference (MDD) between the CT and the cumulative CBCT plans was (0.1 ± 1.1) % (maximum daily MDD of 2%). A reduction in target coverage up to 3% and 7% was observed for the cumulative and daily CBCT plans, respectively. The average kidneys’ cumulative MDD was (−2.7 ± 3.6) % (maximum daily MDD of −12%), corresponding to an overdosage. Conclusion: Due to patient’s diameter changes, a target underdosage was assessed. Given the high local tumor control of neuroblastoma and Wilms’ diseases, the need of re-planning might be discarded. However, the assessed kidneys overdosage could represent a problem when the normal tissue tolerance is reached. The necessity of re-planning should then be considered to reduce the risk of long-term renal complications. Due to the poor softtissue contrast on CBCT, MRI-guidance is required to obtain a better assessment of the accumulated dose on the remaining OARs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kusters, Johannes M.A.M.; Louwe, Rob J.W.; Kollenburg, Peter G.M. van
2011-12-01
Purpose: To develop a treatment technique for craniospinal irradiation using intensity-modulated radiotherapy (IMRT) with improved dose homogeneity at the field junction(s), increased target volume conformity, and minimized dose to the organs at risk (OARs). Methods and Materials: Five patients with high-risk medulloblastoma underwent CT simulation in supine position. For each patient, an IMRT plan with daily intrafractionally modulated junction(s) was generated, as well as a treatment plan based on conventional three-dimensional planning (3DCRT). A dose of 39.6 Gy in 22 daily fractions of 1.8 Gy was prescribed. Dose-volume parameters for target volumes and OARs were compared for the two techniques.more » Results: The maximum dose with IMRT was <107% in all patients. V{sub <95} and V{sub >107} were <1 cm{sup 3} for IMRT compared with 3-9 cm{sup 3} for the craniospinal and 26-43 cm{sup 3} for the spinal-spinal junction with 3DCRT. These observations corresponded with a lower homogeneity index and a higher conformity index for the spinal planning target volume with IMRT. IMRT provided considerable sparing of acute and late reacting tissues. V{sub 75} for the esophagus, gastroesophageal junction, and intestine was 81%, 81%, and 22% with 3DCRT versus 5%, 0%, and 1% with IMRT, respectively. V{sub 75} for the heart and thyroid was 42% and 32% vs. 0% with IMRT. Conclusion: IMRT with daily intrafractionally modulated junction results in a superior target coverage and junction homogeneity compared with 3DCRT. A significant dose reduction can be obtained for acute as well as late-reacting tissues.« less
Clinical use of the co-formulation of insulin degludec and insulin aspart.
Kumar, A; Awata, T; Bain, S C; Ceriello, A; Fulcher, G R; Unnikrishnan, A G; Arechavaleta, R; Gonzalez-Gálvez, G; Hirose, T; Home, P D; Kaku, K; Litwak, L; Madsbad, S; Pinget, M; Mehta, R; Mithal, A; Tambascia, M; Tibaldi, J; Christiansen, J S
2016-08-01
To provide a review of the available data and practical use of insulin degludec with insulin aspart (IDegAsp). Premixed insulins provide basal and prandial glucose control; however, they have an intermediate-acting prandial insulin component and do not provide as effective basal coverage as true long-acting insulins, owing to the physicochemical incompatibility of their individual components, coupled with the inflexibility of adjustment. The molecular structure of the co-formulation of IDegAsp, a novel insulin preparation, allows these two molecules to coexist without affecting their individual pharmacodynamic profiles. Clinical evidence in phase 2/3 trials of IDegAsp efficacy and safety in type 1 and type 2 diabetes mellitus (T1DM and T2DM) have been assessed and summarised. In people with T2DM, once- and twice-daily dosing provides similar overall glycaemic control (HbA1c ) to current modern insulins, but with lower risk of nocturnal hypoglycaemia. In prior insulin users, glycaemic control was achieved with lower or equal insulin doses vs. other basal+meal-time or premix insulin regimens. In insulin-naïve patients with T2DM, IDegAsp can be started once or twice-daily, based on individual need. People switching from more than once-daily basal or premix insulin therapy can be converted unit-to-unit to once-daily IDegAsp, although this strategy should be assessed by the physician on an individual basis. IDegAsp offers physicians and people with T2DM a simpler insulin regimen than other available basal-bolus or premix-based insulin regimens, with stable daytime basal coverage, a lower rate of hypoglycaemia and some flexibility in injection timing compared with premix insulins. © 2016 John Wiley & Sons Ltd.
Nyeng, Tine Bisballe; Nordsmark, Marianne; Hoffmann, Lone
2015-01-01
Some oesophageal cancer patients undergoing chemotherapy and concomitant radiotherapy (chemoRT) show large interfractional anatomical changes during treatment. These changes may modify the dose delivered to the target and organs at risk (OARs). The aim of the presenwt study was to investigate the dosimetric consequences of anatomical changes during treatment to obtain criteria for an adaptive RT decision support system. Twenty-nine patients were treated with chemoRT for oesophageal and gastro-oesophageal junction cancer and set up according to daily cone beam computed tomography (CBCTs) scans. All patients had an additional replanning CT scan at median fraction number 10 (9-14), which was deformably registered to the original planning CT. Gross tumour volumes (GTVs), clinical target volumes (CTVs) and OARs were transferred to the additional CT and corrected by an exwperienced physician. Treatment plans were recalculated and dose to targets and OARs was evaluated. Treatment was adapted if the volume receiving 95% of the prescribed dose (V95%) coverage of CTV decreased > 1% or planning target volume (PTV) decreased by > 3%. In total, nine adaptive events were observed: All nine were triggered by PTV V95% decrease > 3% [median 11% (5-41%)] and six of these were additionally triggered by CTV V95% decrease > 1% [median 5% (2-35%)]. The largest discrepancies were caused by interfractional baseline or amplitude shifts in diaphragm position (n = 5). Mediastinal (n = 6), oesophageal (n = 6) and bowel filling changes (n = 2) caused the remainder of the changes. For patients with dosimetric changes exceeding the adaptation limits, the discrepancies were confirmed by inspecting the daily CBCTs. In 31% of all patients, heart V30Gy increased more than 2% (maximum 5%). Only minor changes in lung dose or liver dose were seen. Target coverage throughout the course of chemoRT treatment is compromised in some patients due to interfractional anatomical changes. Dose to the heart may increase as well.
Correlation between measles vaccine doses: implications for the maintenance of elimination.
McKee, A; Ferrari, M J; Shea, K
2018-03-01
Measles eradication efforts have been successful at achieving elimination in many countries worldwide. Such countries actively work to maintain this elimination by continuing to improve coverage of two routine doses of measles vaccine following measles elimination. While improving measles vaccine coverage is always beneficial, we show, using a steady-state analysis of a dynamical model, that the correlation between populations receiving the first and second routine dose also has a significant impact on the population immunity achieved by a specified combination of first and second dose coverage. If the second dose is administered to people independently of whether they had the first dose, high second-dose coverage improves the proportion of the population receiving at least one dose, and will have a large effect on population immunity. If the second dose is administered only to people who have had the first dose, high second-dose coverage reduces the rate of primary vaccine failure, but does not reach people who missed the first dose; this will therefore have a relatively small effect on population immunity. When doses are administered dependently, and assuming the first dose has higher coverage, increasing the coverage of the first dose has a larger impact on population immunity than does increasing the coverage of the second. Correlation between vaccine doses has a significant impact on the level of population immunity maintained by current vaccination coverage, potentially outweighing the effects of age structure and, in some cases, recent improvements in vaccine coverage. It is therefore important to understand the correlation between vaccine doses as such correlation may have a large impact on the effectiveness of measles vaccination strategies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maynard, M; Chen, K; Rosen, L
Purpose: To evaluate the robustness of the gradient technique for treating a multi-isocenter left chest wall patient with a compact proton pencil beam gantry. Both CBCT and stereoscopic imaging are used to facilitate daily treatment setup. Methods: To treat the elongated chest wall planning target volume (PTV) with the compact PBS system, a 28 fraction (5040 CcGE) treatment plan was created using two fields with gradient matching technique. Daily table shifts between treatment field isocenters were obtained from the record and verify system for each treatment fraction. Copies of the initial treatment plan were made for each fraction and themore » field isocenter coordinates for each plan copy were adjusted to reflect daily table shifts. Doses were re-calculated for each fraction, summed, and compared against the initial plan. Results: The table shifts (average and range) were 2.2 (−5.1–+3.9), 3.0 (−6.0–+4.0) and 3.0 (−10.1–+1.9) millimeters in the anterior-posterior, superior-inferior and right-left directions, respectively. Dose difference to the PTV, heart and ipsilateral lung were evaluated. The percentage of the PTV receiving the prescription dose decreased from 94.6% to 89.1%. The D95 of the PTV increased from 99.6% to 99.9%. The maximum dose in PTV increased from 106.6% to 109.2% and V105 increased from 1.0% to 16.5%. The V20 of the ipsilateral lung increased from 18.5% to 21.0%. The mean heart dose difference was negligible. Conclusion: Observed dose differences to lung and heart tissues due to daily setup variations remained acceptably low while maintaining sufficient dose coverage to the PTV. This initial case study demonstrates the robustness of the gradient technique to treat a large target, multi-isocenter plan with a compact proton pencil beam gantry equipped with CBCT and stereoscopic imaging modalities.« less
Cappellini, Maria Domenica
2007-01-01
Although blood transfusions are important for patients with anemia, chronic transfusions inevitably lead to iron overload as humans cannot actively remove excess iron. The cumulative effects of iron overload lead to significant morbidity and mortality, if untreated. Although the current reference standard iron chelator deferoxamine has been used clinically for over four decades, its effectiveness is limited by a demanding therapeutic regimen that leads to poor compliance. Deferasirox (Exjade®, ICL670, Novartis Pharma AG, Basel, Switzerland) is a once-daily, oral iron chelator approved for the treatment of transfusional iron overload in adult and pediatric patients. The efficacy and safety of deferasirox have been established in a comprehensive clinical development program involving patients with various transfusion-dependent anemias. Deferasirox has a dose-dependent effect on iron burden, and is as efficacious as deferoxamine at comparable therapeutic doses. Deferasirox therapy can be tailored to a patient’s needs, as response is related to both dose and iron intake. Since deferasirox has a long half-life and is present in the plasma for 24 hours with once-daily dosing, it is unique in providing constant chelation coverage with a single dose. The availability of this convenient, effective, and well tolerated therapy represents a significant advance in the management of transfusional iron overload. PMID:18360637
NASA Astrophysics Data System (ADS)
Moteabbed, M.; Trofimov, A.; Sharp, G. C.; Wang, Y.; Zietman, A. L.; Efstathiou, J. A.; Lu, H.-M.
2017-03-01
Proton therapy of prostate by anterior beams could offer an attractive option for treating patients with hip prosthesis and limiting the high-dose exposure to the rectum. We investigated the impact of setup and anatomy variations on the anterior-oblique (AO) proton plan dose, and strategies to manage these effects via range verification and adaptive delivery. Ten patients treated by bilateral (BL) passive-scattering proton therapy (79.2 Gy in 44 fractions) who underwent weekly verification CT scans were selected. Plans with AO beams were additionally created. To isolate the effect of daily variations, initial AO plans did not include range uncertainty margins. The use of fixed planning margins and adaptive range adjustments to manage these effects was investigated. For each case, the planned dose was recalculated on weekly CTs, and accumulated on the simulation CT using deformable registration to approximate the delivered dose. Planned and accumulated doses were compared for each scenario to quantify dose deviations induced by variations. The possibility of estimating the necessary range adjustments before each treatment was explored by simulating the procedure of a diode-based in vivo range verification technique, which would potentially be used clinically. The average planned rectum, penile bulb and femoral heads mean doses were smaller for initial AO compared to BL plans (by 8.3, 16.1 and 25.9 Gy, respectively). After considering interfractional variations in AO plans, the target coverage was substantially reduced. The maximum reduction of V 79.2/D 95/D mean/EUD for AO (without distal margins) (25.3%/10.7/1.6/4.9 Gy, respectively) was considerably larger than BL plans. The loss of coverage was mainly related to changes in water equivalent path length of the prostate after fiducial-based setup, caused by discrepancies in patient anterior surface and bony-anatomy alignment. Target coverage was recovered partially when using fixed planning margins, and fully when applying adaptive range adjustments. The accumulated organs-at-risk dose for AO beams after range adjustment demonstrated full sparing of femoral heads and superior sparing of penile bulb and rectum compared to the conventional BL cases. Our study indicates that using AO beams makes prostate treatment more susceptible to target underdose induced by interfractional variations. Adaptive range verification/adjustment may facilitate the use of anterior beam approaches, and ensure adequate target coverage in every fraction of the treatment.
An evaluation of voluntary 2-dose varicella vaccination coverage in New York City public schools.
Doll, Margaret K; Rosen, Jennifer B; Bialek, Stephanie R; Szeto, Hiram; Zimmerman, Christopher M
2015-05-01
We assessed coverage for 2-dose varicella vaccination, which is not required for school entry, among New York City public school students and examined characteristics associated with receipt of 2 doses. We measured receipt of either at least 1 or 2 doses of varicella vaccine among students aged 4 years and older in a sample of 336 public schools (n = 223 864 students) during the 2010 to 2011 school year. Data came from merged student vaccination records from 2 administrative data systems. We conducted multivariable regression to assess associations of age, gender, race/ethnicity, and school location with 2-dose prevalence. Coverage with at least 1 varicella dose was 96.2% (95% confidence interval [CI] = 96.2%, 96.3%); coverage with at least 2 doses was 64.8% (95% CI = 64.6%, 64.9%). Increasing student age, non-Hispanic White race/ethnicity, and attendance at school in Staten Island were associated with lower 2-dose coverage. A 2-dose varicella vaccine requirement for school entry would likely improve 2-dose coverage, eliminate coverage disparities, and prevent disease.
Human papillomavirus vaccination coverage using two-dose or three-dose schedule criteria.
Lin, Xia; Rodgers, Loren; Zhu, Liping; Stokley, Shannon; Meites, Elissa; Markowitz, Lauri E
2017-10-13
In October 2016, the Advisory Committee on Immunization Practices (ACIP) updated the human papillomavirus (HPV) vaccination recommendation to include a 2-dose schedule for U.S. adolescents initiating the vaccine series before their 15th birthday. We analyzed records for >4million persons aged 9-17years receiving any HPV vaccine by the end of each quarter during January 1, 2014-September 30, 2016 from six Immunization Information Systems Sentinel Sites, and reclassified HPV vaccination up-to-date coverage according to the updated recommendations. Compared with HPV vaccination up-to-date coverage by the 3-dose schedule only, including criteria for either a 2-dose or 3-dose schedule increased up-to-date coverage in 11-12, 13-14, and 15-17 year-olds by 4.5-8.5 percentage points. The difference between 3-dose up-to-date coverage and 2- or 3-dose up-to-date coverage was greatest in late 2016. These data provide baseline HPV vaccination coverage using current ACIP recommendations. Published by Elsevier Ltd.
Court, Laurence E; Tishler, Roy B; Petit, Joshua; Cormack, Robert; Chin, Lee
2006-05-21
This work looks at the feasibility of an online adaptive radiation therapy concept that would detect the daily position and shape of the patient, and would then correct the daily treatment to account for any changes compared with planning position. In particular, it looks at the possibility of developing algorithms to correct for large complicated shape change. For co-planar beams, the dose in an axial plane is approximately associated with the positions of a single multi-leaf collimator (MLC) pair. We start with a primary plan, and automatically generate several secondary plans with gantry angles offset by regular increments. MLC sequences for each plan are calculated keeping monitor units (MUs) and number of segments constant for a given beam (fluences are different). Bulk registration (3D) of planning and daily CT images gives global shifts. Slice-by-slice (2D) registration gives local shifts and rotations about the longitudinal axis for each axial slice. The daily MLC sequence is then created for each axial slice/MLC leaf pair combination, by taking the MLC positions from the pre-calculated plan with the nearest rotation, and shifting using a beam's-eye-view calculation to account for local linear shifts. A planning study was carried out using two head and neck region MR images of a healthy volunteer which were contoured to simulate a base-of-tongue treatment: one with the head straight (used to simulate the planning image) and the other with the head tilted to the left (the daily image). Head and neck treatment was chosen to evaluate this technique because of its challenging nature, with varying internal and external contours, and multiple degrees of freedom. Shape change was significant: on a slice-by-slice basis, local rotations in the daily image varied from 2 to 31 degrees, and local shifts ranged from -0.2 to 0.5 cm and -0.4 to 0.0 cm in right-left and posterior-anterior directions, respectively. The adapted treatment gave reasonable target coverage (100%, 90% and 80% of the base-of-tongue, left nodes and right nodes, respectively, receiving the daily prescription dose), and kept the daily cord dose below the limit used in the original plan (65%, equivalent to 46 Gy over 35 fractions). Most of the loss of coverage was due to one shoulder being raised more superior relative to the other shoulder compared with the plan. This type of skew-like motion is not accounted for by the proposed ART technique. In conclusion, this technique has potential to correct for fairly extreme daily changes in patient setup, but some control of the daily position would still be necessary. Importantly, it was possible to combine treatments from different plans (MLC sequences) to correct for position and shape change.
Developing and implementing a high precision setup system
NASA Astrophysics Data System (ADS)
Peng, Lee-Cheng
The demand for high-precision radiotherapy (HPRT) was first implemented in stereotactic radiosurgery using a rigid, invasive stereotactic head frame. Fractionated stereotactic radiotherapy (SRT) with a frameless device was developed along a growing interest in sophisticated treatment with a tight margin and high-dose gradient. This dissertation establishes the complete management for HPRT in the process of frameless SRT, including image-guided localization, immobilization, and dose evaluation. The most ideal and precise positioning system can allow for ease of relocation, real-time patient movement assessment, high accuracy, and no additional dose in daily use. A new image-guided stereotactic positioning system (IGSPS), the Align RT3C 3D surface camera system (ART, VisionRT), which combines 3D surface images and uses a real-time tracking technique, was developed to ensure accurate positioning at the first place. The uncertainties of current optical tracking system, which causes patient discomfort due to additional bite plates using the dental impression technique and external markers, are found. The accuracy and feasibility of ART is validated by comparisons with the optical tracking and cone-beam computed tomography (CBCT) systems. Additionally, an effective daily quality assurance (QA) program for the linear accelerator and multiple IGSPSs is the most important factor to ensure system performance in daily use. Currently, systematic errors from the phantom variety and long measurement time caused by switching phantoms were discovered. We investigated the use of a commercially available daily QA device to improve the efficiency and thoroughness. Reasonable action level has been established by considering dosimetric relevance and clinic flow. As for intricate treatments, the effect of dose deviation caused by setup errors remains uncertain on tumor coverage and toxicity on OARs. The lack of adequate dosimetric simulations based on the true treatment coordinates from the treatment planning system (TPS) has limited adaptive treatments. A reliable and accurate dosimetric simulation using TPS and in-house software in uncorrected errors has been developed. In SRT, the calculated dose deviation is compared to the original treatment dose with the dose-volume histogram to investigate the dose effect of rotational errors. In summary, this work performed a quality assessment to investigate the overall accuracy of current setup systems. To reach the ideal HPRT, the reliable dosimetric simulation, an effective daily QA program and effective, precise setup systems were developed and validated.
An Evaluation of Voluntary 2-Dose Varicella Vaccination Coverage in New York City Public Schools
Rosen, Jennifer B.; Bialek, Stephanie R.; Szeto, Hiram; Zimmerman, Christopher M.
2015-01-01
Objectives. We assessed coverage for 2-dose varicella vaccination, which is not required for school entry, among New York City public school students and examined characteristics associated with receipt of 2 doses. Methods. We measured receipt of either at least 1 or 2 doses of varicella vaccine among students aged 4 years and older in a sample of 336 public schools (n = 223 864 students) during the 2010 to 2011 school year. Data came from merged student vaccination records from 2 administrative data systems. We conducted multivariable regression to assess associations of age, gender, race/ethnicity, and school location with 2-dose prevalence. Results. Coverage with at least 1 varicella dose was 96.2% (95% confidence interval [CI] = 96.2%, 96.3%); coverage with at least 2 doses was 64.8% (95% CI = 64.6%, 64.9%). Increasing student age, non-Hispanic White race/ethnicity, and attendance at school in Staten Island were associated with lower 2-dose coverage. Conclusions. A 2-dose varicella vaccine requirement for school entry would likely improve 2-dose coverage, eliminate coverage disparities, and prevent disease. PMID:25521904
Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami
2014-05-01
Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less
Qin, An; Sun, Ying; Liang, Jian; Yan, Di
2015-04-01
To evaluate online/offline image-guided/adaptive treatment techniques for prostate cancer radiation therapy with daily cone-beam CT (CBCT) imaging. Three treatment techniques were evaluated retrospectively using daily pre- and posttreatment CBCT images on 22 prostate cancer patients. Prostate, seminal vesicles (SV), rectal wall, and bladder were delineated on all CBCT images. For each patient, a pretreatment intensity modulated radiation therapy plan with clinical target volume (CTV) = prostate + SV and planning target volume (PTV) = CTV + 3 mm was created. The 3 treatment techniques were as follows: (1) Daily Correction: The pretreatment intensity modulated radiation therapy plan was delivered after online CBCT imaging, and position correction; (2) Online Planning: Daily online inverse plans with 3-mm CTV-to-PTV margin were created using online CBCT images, and delivered; and (3) Hybrid Adaption: Daily Correction plus an offline adaptive inverse planning performed after the first week of treatment. The adaptive plan was delivered for all remaining 15 fractions. Treatment dose for each technique was constructed using the daily posttreatment CBCT images via deformable image registration. Evaluation was performed using treatment dose distribution in target and critical organs. Treatment equivalent uniform dose (EUD) for the CTV was within [85.6%, 100.8%] of the pretreatment planned target EUD for Daily Correction; [98.7%, 103.0%] for Online Planning; and [99.2%, 103.4%] for Hybrid Adaptation. Eighteen percent of the 22 patients in Daily Correction had a target dose deficiency >5%. For rectal wall, the mean ± SD of the normalized EUD was 102.6% ± 2.7% for Daily Correction, 99.9% ± 2.5% for Online Planning, and 100.6% ± 2.1% for Hybrid Adaptation. The mean ± SD of the normalized bladder EUD was 108.7% ± 8.2% for Daily Correction, 92.7% ± 8.6% for Online Planning, and 89.4% ± 10.8% for Hybrid Adaptation. Both Online Planning and Hybrid Adaptation can achieve comparable target coverage and normal tissue sparing and are superior to the Daily Correction technique. The Daily Correction technique using a 3-mm target margin in the pretreatment plan is not appropriate to compensate for residual variations in CBCT image-guided prostate cancer radiation therapy. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qin, An; Sun, Ying; Liang, Jian
Purpose: To evaluate online/offline image-guided/adaptive treatment techniques for prostate cancer radiation therapy with daily cone-beam CT (CBCT) imaging. Methods and Materials: Three treatment techniques were evaluated retrospectively using daily pre- and posttreatment CBCT images on 22 prostate cancer patients. Prostate, seminal vesicles (SV), rectal wall, and bladder were delineated on all CBCT images. For each patient, a pretreatment intensity modulated radiation therapy plan with clinical target volume (CTV) = prostate + SV and planning target volume (PTV) = CTV + 3 mm was created. The 3 treatment techniques were as follows: (1) Daily Correction: The pretreatment intensity modulated radiation therapy plan was delivered after online CBCT imaging, and positionmore » correction; (2) Online Planning: Daily online inverse plans with 3-mm CTV-to-PTV margin were created using online CBCT images, and delivered; and (3) Hybrid Adaption: Daily Correction plus an offline adaptive inverse planning performed after the first week of treatment. The adaptive plan was delivered for all remaining 15 fractions. Treatment dose for each technique was constructed using the daily posttreatment CBCT images via deformable image registration. Evaluation was performed using treatment dose distribution in target and critical organs. Results: Treatment equivalent uniform dose (EUD) for the CTV was within [85.6%, 100.8%] of the pretreatment planned target EUD for Daily Correction; [98.7%, 103.0%] for Online Planning; and [99.2%, 103.4%] for Hybrid Adaptation. Eighteen percent of the 22 patients in Daily Correction had a target dose deficiency >5%. For rectal wall, the mean ± SD of the normalized EUD was 102.6% ± 2.7% for Daily Correction, 99.9% ± 2.5% for Online Planning, and 100.6% ± 2.1% for Hybrid Adaptation. The mean ± SD of the normalized bladder EUD was 108.7% ± 8.2% for Daily Correction, 92.7% ± 8.6% for Online Planning, and 89.4% ± 10.8% for Hybrid Adaptation. Conclusions: Both Online Planning and Hybrid Adaptation can achieve comparable target coverage and normal tissue sparing and are superior to the Daily Correction technique. The Daily Correction technique using a 3-mm target margin in the pretreatment plan is not appropriate to compensate for residual variations in CBCT image-guided prostate cancer radiation therapy.« less
Assessment of on-time vaccination coverage in population subgroups: A record linkage cohort study.
Moore, Hannah C; Fathima, Parveen; Gidding, Heather F; de Klerk, Nicholas; Liu, Bette; Sheppeard, Vicky; Effler, Paul V; Snelling, Thomas L; McIntyre, Peter; Blyth, Christopher C
2018-05-31
Reported infant vaccination coverage at age 12 months in Australia is >90%. On-time coverage of the 2-4-6 month schedule and coverage in specific populations is rarely reported. We conducted a population-based cohort study of 1.9 million Australian births, 1996-2012, combining individual birth and perinatal records with immunisation records through probabilistic linkage. We assessed on-time coverage across 13 demographic and perinatal characteristics of diphtheria-tetanus-pertussis vaccines (DTP) defined as vaccination 14 days prior to the scheduled due date, to 30 days afterwards. On-time DTP vaccination coverage in non-Aboriginal infants was 88.1% for the 2-month dose, 82.0% for 4-month dose, and 76.7% for 6-month dose; 3-dose coverage was 91.3% when assessed at 12 months. On-time DTP coverage for Aboriginal infants was 77.0%, 66.5%, and 61.0% for the 2-4-6 month dose; 3-dose coverage at 12 months was 79.3%. Appreciable differences in on-time coverage were observed across population subgroups. On-time coverage in non-Aboriginal infants born to mothers with ≥3 previous pregnancies was 62.5% for the 6-month dose (47.9% for Aboriginal infants); up to 23.5 percentage points lower than for first-borns. Infants born to mothers who smoked during pregnancy had coverage 8.7-10.3 percentage points lower than infants born to non-smoking mothers for the 4- and 6-month dose. A linear relationship was apparent between increasing socio-economic disadvantage and decreasing on-time coverage. On-time coverage of the 2-4-6 month schedule is only 50-60% across specific population subgroups representing a significant avoidable public health risk. Aboriginal infants, multiparous mothers, and those who are socio-economically disadvantaged are key groups most likely to benefit from targeted programs addressing vaccine timeliness. Copyright © 2018. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kranen, Simon van; Hamming-Vrieze, Olga; Wolf, Annelisa
Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation ofmore » the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.« less
The TROPOMI surface UV algorithm
NASA Astrophysics Data System (ADS)
Lindfors, Anders V.; Kujanpää, Jukka; Kalakoski, Niilo; Heikkilä, Anu; Lakkala, Kaisa; Mielonen, Tero; Sneep, Maarten; Krotkov, Nickolay A.; Arola, Antti; Tamminen, Johanna
2018-02-01
The TROPOspheric Monitoring Instrument (TROPOMI) is the only payload of the Sentinel-5 Precursor (S5P), which is a polar-orbiting satellite mission of the European Space Agency (ESA). TROPOMI is a nadir-viewing spectrometer measuring in the ultraviolet, visible, near-infrared, and the shortwave infrared that provides near-global daily coverage. Among other things, TROPOMI measurements will be used for calculating the UV radiation reaching the Earth's surface. Thus, the TROPOMI surface UV product will contribute to the monitoring of UV radiation by providing daily information on the prevailing UV conditions over the globe. The TROPOMI UV algorithm builds on the heritage of the Ozone Monitoring Instrument (OMI) and the Satellite Application Facility for Atmospheric Composition and UV Radiation (AC SAF) algorithms. This paper provides a description of the algorithm that will be used for estimating surface UV radiation from TROPOMI observations. The TROPOMI surface UV product includes the following UV quantities: the UV irradiance at 305, 310, 324, and 380 nm; the erythemally weighted UV; and the vitamin-D weighted UV. Each of these are available as (i) daily dose or daily accumulated irradiance, (ii) overpass dose rate or irradiance, and (iii) local noon dose rate or irradiance. In addition, all quantities are available corresponding to actual cloud conditions and as clear-sky values, which otherwise correspond to the same conditions but assume a cloud-free atmosphere. This yields 36 UV parameters altogether. The TROPOMI UV algorithm has been tested using input based on OMI and the Global Ozone Monitoring Experiment-2 (GOME-2) satellite measurements. These preliminary results indicate that the algorithm is functioning according to expectations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Studenski, M; Stoyanova, R; Abramowitz, M
2015-06-15
Purpose: Previous research has demonstrated that following radiation therapy for prostate cancer, there is a relative increase in positive biopsies in the apex versus the rest of the prostate. The increase could be due to: 1) Inter-fraction apex motion or deformation, 2) Intra-fraction apex motion or deformation, 3) Suboptimal dose coverage in the apex, 4) Tissue composition in the apex and/or 5) Prostate size. In this initial study, the potential for suboptimal dose coverage in the apex was assessed by splitting the prostate planning target volume into the apex (inferior third) and remainder. Methods: 69 patients were selected from 303more » patients treated on a clinical radiotherapy trial for prostate cancer. These patients were selected as they had both a localized (sextant template) 2-year post-treatment biopsy and 3D dose information. Of these patients, 10 had positive biopsies in the apex, 8 in the remainder and 11 in both locations. For all patients, the following dosimetric data was acquired from the apex dose volume histogram: Dmean, Dmax, Dmin, D95% and V100%. Unpaired, one-tailed t-tests were used to test for statistical significance (p < 0.05) between all dosimetric parameters for patients with positive versus negative apical biopsies. Additionally, D95% for the apex was plotted against D95% of the remainder. Results: There was no statistical difference for the selected apical dosimetric parameters for patients with positive versus negative biopsies (p-values > 0.05). No correlation was found between D95% (normalized to the prescription dose) for the apex and remainder (R{sup 2} = 0.0116). Conclusion: No correlation was found between positive apical biopsy and suboptimal dosimetric coverage. Current research is looking into inter-fraction apex motion and deformation as a potential source of the increased apical failure using daily CBCT images.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leicher, Brian, E-mail: bleicher@wpahs.org; Day, Ellen; Colonias, Athanasios
2014-10-01
To describe a dosimetric method using an anterior dose avoidance structure (ADAS) during the treatment planning process for intensity-modulated radiation therapy (IMRT) for patients with anal canal and rectal carcinomas. A total of 20 patients were planned on the Elekta/CMS XiO treatment planning system, version 4.5.1 (Maryland Heights MO) with a superposition algorithm. For each patient, 2 plans were created: one employing an ADAS (ADAS plan) and the other replanned without an ADAS (non-ADAS plan). The ADAS was defined to occupy the volume between the inguinal nodes and primary target providing a single organ at risk that is completely outsidemore » of the target volume. Each plan used the same beam parameters and was analyzed by comparing target coverage, overall plan dose conformity using a conformity number (CN) equation, bowel dose-volume histograms, and the number of segments, daily treatment duration, and global maximum dose. The ADAS and non-ADAS plans were equivalent in target coverage, mean global maximum dose, and sparing of small bowel in low-dose regions (5, 10, 15, and 20 Gy). The mean difference between the CN value for the non-ADAS plans and ADAS plans was 0.04 ± 0.03 (p < 0.001). The mean difference in the number of segments was 15.7 ± 12.7 (p < 0.001) in favor of ADAS plans. The ADAS plan delivery time was shorter by 2.0 ± 1.5 minutes (p < 0.001) than the non-ADAS one. The ADAS has proven to be a powerful tool when planning rectal and anal canal IMRT cases with critical structures partially contained inside the target volume.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shang Qingyang; Qi Peng; Ferjani, Samah
2013-06-15
Purpose: The aim of the study was to evaluate the impact of multileaf collimator (MLC) leaf width on treatment adaptation and delivery accuracy for concurrent treatment of the prostate and pelvic lymph nodes with intensity modulated radiation therapy (IMRT). Methods: Seventy-five kilovoltage cone beam CTs (KV-CBCT) from six patients were included for this retrospective study. For each patient, three different IMRT plans were created based on a planning CT using three different MLC leaf widths of 2.5, 5, and 10 mm, respectively. For each CBCT, the prostate displacement was determined by a dual image registration. Adaptive plans were created bymore » shifting selected MLC leaf pairs to compensate for daily prostate movements. To evaluate the impact of MLC leaf width on the adaptive plan for each daily CBCT, three MLC shifted plans were created using three different leaf widths of MLCs (a total of 225 adaptive treatment plans). Selective dosimetric endpoints for the tumor volumes and organs at risk (OARs) were evaluated for these adaptive plans. Using the planning CT from a selected patient, MLC shifted plans for three hypothetical longitudinal shifts of 2, 4, and 8 mm were delivered on the three linear accelerators to test the deliverability of the shifted plans and to compare the dose accuracy of the shifted plans with the original IMRT plans. Results: Adaptive plans from 2.5 and 5 mm MLCs had inadequate dose coverage to the prostate (D99 < 97%, or D{sub mean} < 99% of the planned dose) in 6%-8% of the fractions, while adaptive plans from 10 mm MLC led to inadequate dose coverage to the prostate in 25.3% of the fractions. The average V{sub 56Gy} of the prostate over the six patients was improved by 6.4% (1.6%-32.7%) and 5.8% (1.5%-35.7%) with adaptive plans from 2.5 and 5 mm MLCs, respectively, when compared with adaptive plans from 10 mm MLC. Pelvic lymph nodes were well covered for all MLC adaptive plans, as small differences were observed for D99, D{sub mean}, and V{sub 50.4Gy}. Similar OAR sparing could be achieved for the bladder and rectum with all three MLCs for treatment adaptation. The MLC shifted plans can be accurately delivered on all three linear accelerators with accuracy similar to their original IMRT plans, where gamma (3%/3 mm) passing rates were 99.6%, 93.0%, and 92.1% for 2.5, 5, and 10 mm MLCs, respectively. The percentages of pixels with dose differences between the measurement and calculation being less than 3% of the maximum dose were 85.9%, 82.5%, and 70.5% for the original IMRT plans from the three MLCs, respectively. Conclusions: Dosimetric advantages associated with smaller MLC leaves were observed in terms of the coverage to the prostate, when the treatment was adapted to account for daily prostate movement for concurrent irradiation of the prostate and pelvic lymph nodes. The benefit of switching the MLC from 10 to 5 mm was significant (p Much-Less-Than 0.01); however, switching the MLC from 5 to 2.5 mm would not gain significant (p= 0.15) improvement. IMRT plans with smaller MLC leaf widths achieved more accurate dose delivery.« less
NASA Astrophysics Data System (ADS)
Houweling, Antonetta C.; Crama, Koen; Visser, Jorrit; Fukata, Kyohei; Rasch, Coen R. N.; Ohno, Tatsuya; Bel, Arjan; van der Horst, Astrid
2017-04-01
Radiotherapy using charged particles is characterized by a low dose to the surrounding healthy organs, while delivering a high dose to the tumor. However, interfractional anatomical changes can greatly affect the robustness of particle therapy. Therefore, we compared the dosimetric impact of interfractional anatomical changes (i.e. body contour differences and gastrointestinal gas volume changes) in photon, proton and carbon ion therapy for pancreatic cancer patients. In this retrospective planning study, photon, proton and carbon ion treatment plans were created for 9 patients. Fraction dose calculations were performed using daily cone-beam CT (CBCT) images. To this end, the planning CT was deformably registered to each CBCT; gastrointestinal gas volumes were delineated on the CBCTs and copied to the deformed CT. Fraction doses were accumulated rigidly. To compare planned and accumulated dose, dose-volume histogram (DVH) parameters of the planned and accumulated dose of the different radiotherapy modalities were determined for the internal gross tumor volume, internal clinical target volume (iCTV) and organs-at-risk (OARs; duodenum, stomach, kidneys, liver and spinal cord). Photon plans were highly robust against interfractional anatomical changes. The difference between the planned and accumulated DVH parameters for the photon plans was less than 0.5% for the target and OARs. In both proton and carbon ion therapy, however, coverage of the iCTV was considerably reduced for the accumulated dose compared with the planned dose. The near-minimum dose ({{D}98 % } ) of the iCTV reduced with 8% for proton therapy and with 10% for carbon ion therapy. The DVH parameters of the OARs differed less than 3% for both particle modalities. Fractionated radiotherapy using photons is highly robust against interfractional anatomical changes. In proton and carbon ion therapy, such changes can severely reduce the dose coverage of the target.
Ogbuanu, Ikechukwu U.; Adegoke, Oluwasegun J.; Scobie, Heather M.; Uba, Belinda V.; Wannemuehler, Kathleen A.; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J.; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F.
2016-01-01
Background Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Methods Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014–2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12–23 months was documented based on vaccination card or caretaker’s recall. District-level coverage estimates were calculated using survey methods. Results Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1–63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%–139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Conclusions Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria. PMID:27936077
Gunnala, Rajni; Ogbuanu, Ikechukwu U; Adegoke, Oluwasegun J; Scobie, Heather M; Uba, Belinda V; Wannemuehler, Kathleen A; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F
2016-01-01
Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014-2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12-23 months was documented based on vaccination card or caretaker's recall. District-level coverage estimates were calculated using survey methods. Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1-63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%-139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria.
Measles vaccination response during Kosi floods, Bihar, India 2008.
Varkey, Sherin; Krishna, Gopal; Pradhan, Narottam; Gupta, Satish Kumar; Caravotta, Jorge; Hombergh, Henri Vanden; Hoekstra, Edward; Askari, Sufia; Kansal, O P
2009-11-01
The Kosi floods of Bihar in 2008 led to initial rapid displacement followed by rehabilitation of the affected population. Strategically planned phase-wise activity of supplementary as well as primary measles vaccination combined with a variety of other interventions proved to be successful in preventing outbreaks and deaths due to measles. While 70% supplementary measles vaccination coverage was achieved in relief camps, the coverage of primary measles doses in the latter phases was dependant on accessibility of villages and previous vaccination status of eligible beneficiaries. The integrated diseases surveillance system, which became operational during the floods, also complemented the vaccination efforts by providing daily figures of cases with fever and rash. The overall response was not only successful in terms of preventing measles mortality, but also provided vital lessons that may be useful for planning future vaccination responses in emergency settings.
Tippins, Ashley; Murthy, Neil; Meghani, Mehreen; Solsman, Amy; Apaisam, Carter; Basilius, Merlyn; Eckert, Maribeth; Judicpa, Peter; Masunu, Yolanda; Pistotnik, Kelsey; Pedro, Daisy; Sasamoto, Jeremy; Underwood, J Michael
2018-05-25
Vaccine-preventable diseases (VPDs) cause substantial morbidity and mortality in the United States Affiliated Pacific Islands (USAPI).* CDC collaborates with USAPI immunization programs to monitor vaccination coverage. In 2016, † USAPI immunization programs and CDC piloted a method for estimating up-to-date status among children aged 2 years using medical record abstraction to ascertain regional vaccination coverage. This was the first concurrent assessment of childhood vaccination coverage across five USAPI jurisdictions (American Samoa; Chuuk State, Federated States of Micronesia [FSM]; Commonwealth of the Northern Mariana Islands [CNMI]; Republic of the Marshall Islands [RMI]; and Republic of Palau). § Differences in vaccination coverage between main and outer islands ¶ were assessed for two jurisdictions where data were adequate.** Series coverage in this report includes the following doses of vaccines: ≥4 doses of diphtheria and tetanus toxoids and acellular pertussis vaccine (DTaP); ≥3 doses of inactivated poliovirus vaccine (IPV); ≥1 dose of measles, mumps, and rubella vaccine (MMR); ≥3 doses of Haemophilus influenzae type B (Hib) vaccine; ≥3 doses of hepatitis B (HepB) vaccine; and ≥4 doses of pneumococcal conjugate vaccine (PCV); i.e., 4:3:1:3:3:4. Coverage with ≥3 doses of rotavirus vaccine was also assessed. Completion of the recommended series of each of these vaccines †† was <90% in all jurisdictions except Palau. Coverage with the full recommended six-vaccine series (4:3:1:3:3:4) ranged from 19.5% (Chuuk) to 69.1% (Palau). In RMI and Chuuk, coverage was lower in the outer islands than in the main islands for most vaccines, with differences ranging from 0.9 to 66.8 percentage points. Medical record abstraction enabled rapid vaccination coverage assessment and timely dissemination of results to guide programmatic decision-making. Effectively monitoring vaccination coverage, coupled with implementation of data-driven interventions, is essential to maintain protection from VPD outbreaks in the region and the mainland United States.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jurkovic, I; Stathakis, S; Markovic, M
Purpose: To assess the value of cone beam CT (CBCT) combined with deformable image registration in estimating the accuracy of the delivered treatment and the suitability of the applied target margins. Methods: Two patients with lung tumor were selected. Using their CT images intensity modulated radiation therapy (IMRT) treatment plans were developed to deliver 66Gy to the 95% of the PTV in 2Gy fractions. Using the Velocity AI software, the planning CT of each patient was registered with the fractional CBCT images that were obtained through the course of the treatment. After a CT to CBCT deformable image registration (DIR),more » the same fractional deformation matrix was used for the deformation of the planned dose distributions, as well as of all the contoured volumes, to each CBCT dataset. The dosimetric differences between the planning target volume (PTV) and various organs at risk (OARs) were recorded and compared. Results: CBCT data such as CTV volume change and PTV coverage was analyzed. There was a moderate relationship between volume changes and contouring method (automatic contouring using the DIR transformation vs. manual contouring on each CBCT) for patient #1 (r = 0.49), and a strong relationship for patient #2 (r = 0.83). The average PTV volume coverage from all the CBCT datasets was 91.2% for patient #1 and 95.6% for patient #2. Conclusion: Daily setup variations, tumor volume motion and lung deformation due to breathing yield differences in the actual delivered dose distributions versus the planned ones. The results presented indicate that these differences are apparent even with the use of daily IGRT. In certain fractions, the margins used seem to be insufficient to ensure acceptable lung tumor coverage. The observed differences notably depend on the tumor volume size and location. A larger cohort of patient is under investigation to verify those findings.« less
Healy, Jessica; Rodriguez-Lainz, Alfonso; Elam-Evans, Laurie D; Hill, Holly A; Reagan-Steiner, Sarah; Yankey, David
2018-03-20
An overall increase has been reported in vaccination rates among adolescents during the past decade. Studies of vaccination coverage have shown disparities when comparing foreign-born and U.S.-born populations among children and adults; however, limited information is available concerning potential disparities in adolescents. The National Immunization Survey-Teen is a random-digit-dialed telephone survey of caregivers of adolescents aged 13-17 years, followed by a mail survey to vaccination providers that is used to estimate vaccination coverage among the U.S. population of adolescents. Using the National Immunization Survey-Teen data, we assessed vaccination coverage during 2012-2014 among adolescents for routinely recommended vaccines for this age group (≥1 dose tetanus and diphtheria toxoids and acellular pertussis [Tdap] vaccine, ≥1 dose quadrivalent meningococcal conjugate [MenACWY] vaccine, ≥3 doses human papillomavirus [HPV] vaccine) and for routine childhood vaccination catch-up doses (≥2 doses measles, mumps, and rubella [MMR] vaccine, ≥2 doses varicella vaccine, and ≥3 doses hepatitis B [HepB] vaccine). Vaccination coverage prevalence and vaccination prevalence ratios were estimated. Of the 58,090 respondents included, 3.3% were foreign-born adolescents. Significant differences were observed between foreign-born and U.S.-born adolescents for insurance status, income-to-poverty ratio, education, interview language, and household size. Foreign-born adolescents had significantly lower unadjusted vaccination coverage for HepB (89% vs. 93%), and higher coverage for the recommended ≥3 doses of HPV vaccine among males, compared with U.S.-born adolescents (22% vs. 14%). Adjustment for demographic and socioeconomic factors accounted for the disparity in HPV but not HepB vaccination coverage. We report comparable unadjusted vaccination coverage among foreign-born and U.S.-born adolescents for Tdap, MenACWY, MMR, ≥2 varicella. Although coverage was high for HepB vaccine, it was significantly lower among foreign-born adolescents, compared with U.S.-born adolescents. HPV and ≥2-dose varicella vaccination coverage were low among both groups. Published by Elsevier Ltd.
Varan, Aiden K; Rodriguez-Lainz, Alfonso; Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Li, Qian
2017-08-01
Healthy People 2020 targets high vaccination coverage among children. Although reductions in coverage disparities by race/ethnicity have been described, data by nativity are limited. The National Immunization Survey is a random-digit-dialed telephone survey that estimates vaccination coverage among U.S. children aged 19-35 months. We assessed coverage among 52,441 children from pooled 2010-2012 data for individual vaccines and the combined 4:3:1:3*:3:1:4 series (which includes ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine/diphtheria and tetanus toxoids vaccine/diphtheria, tetanus toxoids, and pertussis vaccine, ≥3 doses of poliovirus vaccine, ≥1 dose of measles-containing vaccine, ≥3 or ≥4 doses of Haemophilus influenzae type b vaccine (depending on product type of vaccine; denoted as 3* in the series name), ≥3 doses of hepatitis B vaccine, ≥1 dose of varicella vaccine, and ≥4 doses of pneumococcal conjugate vaccine). Coverage estimates controlling for sociodemographic factors and multivariable logistic regression modeling for 4:3:1:3*:3:1:4 series completion are presented. Significantly lower coverage among foreign-born children was detected for DTaP, hepatitis A, hepatitis B, Hib, pneumococcal conjugate, and rotavirus vaccines, and for the combined series. Series completion disparities persisted after control for demographic, access-to-care, poverty, and language effects. Substantial and potentially widening disparities in vaccination coverage exist among foreign-born children. Improved immunization strategies targeting this population and continued vaccination coverage monitoring by nativity are needed.
Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy.
Rong, Yi; Yadav, Poonam; Welsh, James S; Fahner, Tasha; Paliwal, Bhudatt
2012-01-01
The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments. Published by Elsevier Inc.
Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rong Yi, E-mail: rong@humonc.wisc.edu; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI; Yadav, Poonam
2012-10-01
The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTVmore » received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhen, H; Wu, Z; Bluemenfeld, P
Purpose Daily setup for definitive prostatic radiotherapy is challenged by suboptimal visibility of the prostate boundary and daily variation of rectum shape and position. For patients with improved bowel preparation, we conducted a dosimetric comparison between prostate implanted marker (IM)-based daily setup and anterior rectal wall (ARW)-based setup, with the hypothesis that the former leads to adequate target coverage with better rectal sparing. Methods Five IMRT/VMAT prostate cases with implanted markers were selected for analysis. Daily CBCT showed improvement of the rectal volume compared to planning CT. For each patient, the prostate and rectum were contoured on three CBCT imagesmore » (fraction 5/15/25) with subsequent physician review. The CBCTs were then registered to a planning CT using IM-based registration. The deviation of ARW positions from planning CT to CBCT were analyzed at various sup-inf levels (−1.8 cm to 1.8 cm from level of prostate center). To estimate the potential dosimetric impact from ARW-based setup, the treatment plans were recalculated using A-P shifts ranging from −1mm to +6mm. Clinically important rectum DVH values including Dmax, D3cc and Dmean were computed. Results For the studied patients, we observed on average 32% rectum volume reduction from planning CT to CBCT. As a Results, the ARW on average shifts posteriorly by −1mm to +5mm, depending on the sup-inf level of observation, with larger shifts observed at more superior levels. Recalculation shows that when ARW shifts 1mm posteriorly, ARW-based CBCT setup leads to a 1.0%, 4.2%, and 3.2% increase in rectum Dmax, D3cc, and Dmean, respectively, compared to IM-based setup. The dosimetric deviations increase to 4.7%, 25.8% and 24.7% when ARW shifts 6mm posteriorly. No significant prostate-only dose difference was observed. Conclusion For patients with improved bowel preparation, IM-based CBCT setup leads to accurate prostate coverage along with significantly lower rectal dose, compared to ARW-based setup.« less
Poster - 34: Clinical Implementation of Prone Breast Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Runqing; Fleming, Katrina; Kobeleva, Sofya
2016-08-15
Purpose: Prone breast treatment is used to reduce acute and late toxicities for large or pendulous breast patients. This study developed and implemented the clinical workflow of prone breast radiotherapy treatment. Methods: Varian kVue Access360™ Prone Breast Couchtop was used as prone breast board. The treatment planning (TP)is performed in Eclipse TP system. TP comparisons between supine deep inspiration breathing hold (DIBH) and prone breast; prone forward field-in-field (FinF) planning and inverse IMRT planning were performed and discussed. For the daily setup, breast coverage was assessed in the room using light field and MV imaging was used at day 1more » and weekly. Results: The first ten patients are CT scanned and planned both supine and prone. The coverage was all excellent for supine DIBH plan and prone breast plan. The plan in the prone position demonstrated improvements in lung sparing comparing to the DIBH plan. Both forward FinF plan and inverse IMRT plan achieved acceptable coverage of the breast, and heart dose is comparable. Considering the daily setup variations and MLC leakage, forward FinF plan was recommended for routine clinical use. The procedure has been tested in phantom and patients were treated clinically. Conclusions: Prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. The workflow for prone breast radiation therapy has been developed and the technique is ready to treat patients.« less
Dose conformation to the spine during palliative treatments using dynamic wedges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ormsby, Matthew A., E-mail: Matthew.Ormsby@usoncology.com; Herndon, R. Craig; Kaczor, Joseph G.
2013-07-01
Radiation therapy is commonly used to alleviate pain associated with metastatic disease of the spine. Often, isodose lines are manipulated using dynamic or physical wedges to encompass the section of spine needing treatment while minimizing dose to normal tissue. We will compare 2 methods used to treat the entire thoracic spine. The first method treats the thoracic spine with a single, nonwedged posterior-anterior (PA) field. Dose is prescribed to include the entire spine. Isodose lines tightly conform to the top and bottom vertebrae, but vertebrae between these 2 received more than enough coverage. The second method uses a combination ofmore » wedges to create an isodose line that mimics the curvature of the thoracic spine. This “C”-shaped curvature is created by overlapping 2 fields with opposing dynamic wedges. Machine constraints limit the treatment length and therefore 2 isocenters are used. Each of the 2 PA fields contributes a portion of the total daily dose. This technique creates a “C”-shaped isodose line that tightly conforms to the thoracic spine, minimizing normal tissue dose. Spinal cord maximum dose is reduced, as well as mean dose to the liver, esophagus, and heart.« less
Smoking behaviour and health care costs coverage: a European cross-country comparison.
Rezayatmand, Reza; Groot, Wim; Pavlova, Milena
2017-12-01
The empirical evidence about the effect of smoking on health care cost coverage is not consistent with the expectations based on the notion of adverse selection. This evidence is mostly based on correlational studies which cannot isolate the adverse selection effect from the moral hazard effect. Exploiting data from the Survey of Health, Aging, and Retirement in Europe, this study uses an instrumental variable strategy to identify the causal effect of daily smoking on perceived health care cost coverage of those at age 50 or above in 12 European countries. Daily smoking is instrumented by a variable indicating whether or not there is any other daily smoker in the household. A self-assessment of health care cost coverage is used as the outcome measure. Among those who live with a partner (72% of the sample), the result is not statistically significant which means we find no effect of smoking on perceived health care cost coverage. However, among those who live without a partner, the results show that daily smokers have lower self-assessed perceived health care cost coverage. This finding replicates the same counter-intuitive relationship between smoking and health insurance presented in previous studies, but in a language of causality. In addition to this, we contribute to previous studies by a cross-country comparison which brings in different institutional arrangements, and by using the self-assessed perceived health care cost coverage which is broader than health insurance coverage.
Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Singleton, James A; Kolasa, Maureen
2015-08-28
The reduction in morbidity and mortality associated with vaccine-preventable diseases in the United States has been described as one of the 10 greatest public health achievements of the first decade of the 21st century. A recent analysis concluded that routine childhood vaccination will prevent 322 million cases of disease and about 732,000 early deaths among children born during 1994-2013, for a net societal cost savings of $1.38 trillion. The National Immunization Survey (NIS) has monitored vaccination coverage among U.S. children aged 19-35 months since 1994. This report presents national, regional, state, and selected local area vaccination coverage estimates for children born from January 2011 through May 2013, based on data from the 2014 NIS. For most vaccinations, there was no significant change in coverage between 2013 and 2014. The exception was hepatitis A vaccine (HepA), for which increases were observed in coverage with both ≥1 and ≥2 doses. As in previous years, <1% of children received no vaccinations. National coverage estimates indicate that the Healthy People 2020 target* of 90% was met for ≥3 doses of poliovirus vaccine (93.3%), ≥1 dose of measles, mumps, and rubella vaccine (MMR) (91.5%), ≥3 doses of hepatitis B vaccine (HepB) (91.6%), and ≥1 dose of varicella vaccine (91.0%). Coverage was below target for ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine (DTaP), the full series of Haemophilus influenzae type b (Hib) vaccine, hepatitis B (HepB) birth dose,† ≥4 doses pneumococcal conjugate vaccine (PCV), ≥2 doses of HepA, the full series of rotavirus vaccine, and the combined vaccine series.§ Examination of coverage by child's race/ethnicity revealed lower estimated coverage among non-Hispanic black children compared with non-Hispanic white children for several vaccinations, including DTaP, the full series of Hib, PCV, rotavirus vaccine, and the combined series. Children from households classified as below the federal poverty level had lower estimated coverage for almost all of the vaccinations assessed, compared with children living at or above the poverty level. Significant variation in coverage by state¶ was observed for several vaccinations, including HepB birth dose, HepA, and rotavirus. High vaccination coverage must be maintained across geographic and sociodemographic groups if progress in reducing the impact of vaccine-preventable diseases is to be sustained.
Lu, Peng-Jun; Yankey, David; Jeyarajah, Jenny; O'Halloran, Alissa; Fredua, Benjamin; Elam-Evans, Laurie D; Reagan-Steiner, Sarah
2018-04-01
To assess selected vaccination coverage among adolescents by health insurance status and other access-to-care characteristics. The 2015 National Immunization Survey-Teen data were used to assess vaccination coverage disparities among adolescents by health insurance status and other access-to-care variables. Multivariable logistic regression analysis and a predictive marginal modeling were conducted to evaluate associations between health insurance status and vaccination coverage. Overall, vaccination coverage was significantly lower among uninsured compared with insured adolescents for all vaccines assessed for except ≥3 doses of human papillomavirus vaccine (HPV) among male adolescents. Among adolescents 13-17 years of age, vaccination of uninsured compared with insured adolescents, respectively, for tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine was 77.4% vs 86.8%; for ≥1 dose of meningococcal conjugate vaccine was 72.9% vs 81.7%; for ≥1 dose of HPV was 38.8% vs 50.2% among male and 42.9% vs 63.8% among female adolescents; for 3 doses of HPV was 24.9% vs 42.8% among female adolescents. In addition, vaccination coverage differed by the following: type of insurance among insured adolescents, having a well-child visit at 11-12 years of age, and number of healthcare provider contacts in the past year. Uninsured were less likely than insured adolescents to be vaccinated for HPV (female: ≥1 dose and 3 doses; and male: ≥1 doses) after adjusting for confounding variables. Overall, vaccination coverage was lower among uninsured adolescents. HPV vaccination coverage was lower than tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine Tdap and meningococcal conjugate vaccine in both insured and uninsured adolescents. Wider implementation of effective evidence-based strategies is needed to help improve vaccination coverage among adolescents, particularly for those who are uninsured. Limitation of current federally funded vaccination programs or access to healthcare would be expected to erode vaccine coverage of adolescents. Published by Elsevier Inc.
Fast online replanning for interfraction rotation correction in prostate radiotherapy.
Kontaxis, Charis; Bol, Gijsbert H; Kerkmeijer, Linda G W; Lagendijk, Jan J W; Raaymakers, Bas W
2017-10-01
To enable fast online replanning for prostate radiotherapy with the inclusion of interfraction rotations and translations and investigate the possibility for margin reduction via this regime. Online daily replanning for a 35-fraction treatment for five prostate cases is simulated while accounting for anatomical transformations derived from fiducial marker data available in our clinic. Two online replanning strategies were simulated, compensating for: (a) rotation-only in combination with a couch shift and (b) both translation and rotation without a couch shift. They were compared against our current clinical protocol consisting of a single offline plan used over all fractions with daily couch repositioning (translations only). For every patient, the above methods were generated for several planning margins (0-8 mm with 2 mm increments) in order to assess the performance of online replanning in terms of target coverage and investigate the possible dosimetric benefit for the organs at risk. The daily DVHs for each treatment strategy were used for evaluation and the non tumor integral dose (NTID) for the different margins was calculated in order to quantify the overall reduction of the delivered energy to the patient. Our system is able to generate a daily automated prostate plan in less than 2 min. For every patient, the daily treatment plans produce similar dose distributions to the original approved plan (average CTV D99 relative difference: 0.2%). The inclusion of both shifts and rotations can be effectively compensated via replanning among all planning margins (average CTV D99 difference: 0.01 Gy between the two replanning regimes). Online replanning is able to maintain target coverage among all margins, while - as expected - the conventional treatment plan is increasingly affected by the interfraction rotations as the margins shrink (average CTV D99 decrease: 0.2 Gy at 8 mm to 2.9 Gy at 0 mm margin). The possible gain in total delivered energy to the patient was quantified by the decreased NTID ranging from 12.6% at 6 mm to 32.9% at 0 mm. We demonstrate that fast daily replanning can be utilized to account for daily rotations and translations based on the daily positioning protocol. A daily plan can be generated from scratch in less than 2 min making it suitable for online application. Given the large magnitude of prostate rotation around the LR axis, online correction for daily rotations can be beneficial even for the clinical 8 mm margin and could be utilized for treatments with small margin reduction mainly limited then by anatomical deformations and intrafraction motion. Our online replanning pipeline can be used in future treatments with online MR guidance that can lead to further safe reduction of the planning margins. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
NSW annual immunisation coverage report, 2011.
Hull, Brynley; Dey, Aditi; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B
2012-12-01
This annual report, the third in the series, documents trends in immunisation coverage in NSW for children, adolescents and the elderly, to the end of 2011. Data from the Australian Childhood Immunisation Register, the NSW School Immunisation Program and the NSW Population Health Survey were used to calculate various measures of population coverage. During 2011, greater than 90% coverage was maintained for children at 12 and 24 months of age. For children at 5 years of age the improvement seen in 2010 was sustained, with coverage at or near 90%. For adolescents, there was improved coverage for all doses of human papillomavirus vaccine, both doses of hepatitis B vaccine, varicella vaccine and the dose of diphtheria, tetanus and acellular pertussis given to school attendees in Years 7 and 10. Pneumococcal vaccination coverage in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. This report provides trends in immunisation coverage in NSW across the age spectrum. The inclusion of coverage estimates for the pneumococcal conjugate, varicella and meningococcal C vaccines in the official coverage assessments for 'fully immunised' in 2013 is a welcome initiative.
Henke, Lauren; Kashani, Rojano; Yang, Deshan; Zhao, Tianyu; Green, Olga; Olsen, Lindsey; Rodriguez, Vivian; Wooten, H. Omar; Li, H. Harold; Hu, Yanle; Bradley, Jeffrey; Robinson, Clifford; Parikh, Parag; Michalski, Jeff; Mutic, Sasa; Olsen, Jeffrey
2017-01-01
Purpose/Objectives Stereotactic body radiotherapy (SBRT) is increasingly used to treat oligometastatic or unresectable primary malignancy, although proximity of organs-at-risk (OAR) may limit delivery of sufficiently ablative dose. Magnetic resonance (MR)-based online-adaptive radiotherapy (ART) has potential to improve SBRT’s therapeutic ratio. This study characterizes potential advantages of online-adaptive MR-guided SBRT to treat oligometastatic disease of the non-liver abdomen and central thorax. Materials/Methods Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR-IGRT system. SBRT plans were created based on tumor/OAR anatomy at initial CT simulation (PI) and simulated adaptive plans were created based on observed MR-image set tumor/OAR “anatomy-of-the-day” (PA). Each PA was planned under workflow constraints to simulate online-ART. Prescribed dose was 50Gy/5fractions with goal coverage of 95% PTV by 95% of the prescription, subject to hard OAR constraints. PI was applied to each MR dataset and compared to PA to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results Hard OAR constraints were met for all PI based on anatomy from initial CT simulation, and all PA based on anatomy from each daily MR-image set. Application of the PI to anatomy-of-the-day caused OAR constraint violation in 19/30 cases. Adaptive planning increased PTV coverage in 21/30 cases, including 14 cases where hard OAR constraints were violated by the non-adaptive plan. For 9 PA cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a non-adaptive setting. Conclusions Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared to non-adaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique. PMID:27742541
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mooney, K; Altman, M; Garcia-Ramirez, J
Purpose: Treatment planning guidelines for accelerated partial breast irradiation (ABPI) using the strut-adjusted volume implant (SAVI) are inconsistent between the manufacturer and NSABP B-39/RTOG 0413 protocol. Furthermore neither set of guidelines accounts for different applicator sizes. The purpose of this work is to establish guidelines specific to the SAVI that are based on clinically achievable dose distributions. Methods: Sixty-two consecutive patients were implanted with a SAVI and prescribed to receive 34 Gy in 10 fractions twice daily using high dose-rate (HDR) Ir-192 brachytherapy. The target (PTV-EVAL) was defined per NSABP. The treatments were planned and evaluated using a combination ofmore » dosimetric planning goals provided by the NSABP, the manufacturer, and our prior clinical experience. Parameters evaluated included maximum doses to skin and ribs, and volumes of PTV-EVAL receiving 90%, 95%, 100%, 150%, and 200% of the prescription (V90, etc). All target parameters were evaluated for correlation with device size using the Pearson correlation coefficient. Revised dosimetric guidelines for target coverage and heterogeneity were determined from this population. Results: Revised guidelines for minimum target coverage (ideal in parentheses): V90≥95%(97%), V95≥90%(95%), V100≥88%(91%). The only dosimetric parameters that were significantly correlated (p<0.05) with device size were V150 and V200. Heterogeneity criteria were revised for the 6–1 Mini/6-1 applicators to V150≤30cc and V200≤15cc, and unchanged for the other sizes. Re-evaluation of patient plans showed 90% (56/62) met the revised minimum guidelines and 76% (47/62) met the ideal guidelines. All and 56/62 patients met our institutional guidelines for maximum skin and rib dose, respectively. Conclusions: We have optimized dosimetric guidelines for the SAVI applicators, and found that implementation of these revised guidelines for SAVI treatment planning yielded target coverage exceeding that required by existing guidelines while preserving heterogeneity constraints and minimizing dose to organs at risk.« less
Cantin, Audrey; Gingras, Luc; Lachance, Bernard; Foster, William; Goudreault, Julie; Archambault, Louis
2015-12-01
The movements of the prostate relative to the pelvic lymph nodes during intensity-modulated radiation therapy treatment can limit margin reduction and affect the protection of the organs at risk (OAR). In this study, the authors performed an analysis of three adaptive treatment strategies that combine information from both bony and gold marker registrations. The robustness of those treatments against the interfraction prostate movements was evaluated. A retrospective study was conducted on five prostate cancer patients with 7-13 daily cone-beam CTs (CBCTs). The clinical target volumes (CTVs) consisting of pelvic lymph nodes, prostate, and seminal vesicles as well as the OARs were delineated on each CBCT and the initial CT. Three adaptive strategies were analyzed. Two of these methods relied on a two-step patient positioning at each fraction. First step: a bony registration was used to deliver the nodal CTV prescription. Second step: a gold marker registration was then used either to (1) complete the dose delivered to the prostate (complement); (2) or give almost the entire prescription to the prostate with a weak dose gradient between the targets to compensate for possible motions (gradient). The third method (COR) used a pool of precalculated plans based on images acquired at previous treatment fractions. At each new fraction, a plan is selected from that pool based on the daily position of prostate center-of-mass. The dosimetric comparison was conducted and results are presented with and without the systematic shift in the prostate position on the CT planning. The adaptive strategies were compared to the current clinical standard where all fractions are treated with the initial nonadaptive plan. The minimum daily prostate D95% is improved by 2%, 9%, and 6% for the complement, the gradient, and the COR approaches, respectively, compared to the nonadaptive method. The average nodal CTV D95% remains constant across the strategies, except for the gradient approach where a reduction of 7% is observed. However, a correction of the systematic shift reduced the problem, and the adaptive strategies remain robust against the prostate movement across the fraction. The bladder V55Gy is reduced by 35% on average for the adaptive strategies. Because they offer increased CTV coverage and OAR sparing, adaptive methods may be suitable candidates for simple and efficient adaptive treatment strategies for prostate cancer. Margin reduction and systematic error correction in the prostate position improve the protection of the OAR and the dose coverage. A cumulative dose to simulate a complete treatment would show real effects and allow a better comparison between each method.
Irving, Stephanie A; Groom, Holly C; Stokley, Shannon; McNeil, Michael M; Gee, Julianne; Smith, Ning; Naleway, Allison L
2018-03-01
Human papillomavirus (HPV) vaccination has been recommended in the United States for female and male adolescents since 2006 and 2011, respectively. Coverage rates are lower than those for other adolescent vaccines. The objective of this study was to evaluate an assessment and feedback intervention designed to increase HPV vaccination coverage and quantify missed opportunities for HPV vaccine initiation at preventive care visits. We examined changes in HPV vaccination coverage and missed opportunities within the adolescent (11-17 years) population at 9 Oregon-based Kaiser Permanente Northwest outpatient clinics after an assessment and feedback intervention. Quarterly coverage rates were calculated for the adolescent populations at the clinics, according to age group (11-12 and 13-17 years), sex, and department (Pediatrics and Family Medicine). Comparison coverage assessments were calculated at 3 nonintervention (control) clinics. Missed opportunities for HPV vaccine initiation, defined as preventive care visits in which a patient eligible for HPV dose 1 remained unvaccinated, were examined according to sex and age group. An average of 29,021 adolescents were included in coverage assessments. Before the intervention, 1-dose and 3-dose quarterly coverage rates were increasing at intervention as well as at control clinics in both age groups. Postimplementation quarterly trends in 1-dose or 3-dose coverage did not differ significantly between intervention and control clinics for either age group. One-dose coverage rates among adolescents with Pediatrics providers were significantly higher than those with Family Medicine providers (56% vs 41% for 11- to 12-year-old and 82% vs 69% for 13- to 17-year-old girls; 55% vs 40% for 11- to 12-year-old and 78% vs 62% for 13- to 17-year-old boys). No significant differences in HPV vaccine coverage were identified at intervention clinics. However, coverage rates were increasing before the start of the intervention and might have been influenced by ongoing health system best practices. HPV vaccine coverage rates varied significantly according to department, which could allow for targeted improvement opportunities. Copyright © 2017 Academic Pediatric Association. All rights reserved.
Impact of organ shape variations on margin concepts for cervix cancer ART.
Seppenwoolde, Yvette; Stock, Markus; Buschmann, Martin; Georg, Dietmar; Bauer-Novotny, Kwei-Yuang; Pötter, Richard; Georg, Petra
2016-09-01
Target and organ movement motivate adaptive radiotherapy for cervix cancer patients. We investigated the dosimetric impact of margin concepts with different levels of complexity on both organ at risk (OAR) sparing and PTV coverage. Weekly CT and daily CBCT scans were delineated for 10 patients. The dosimetric impact of organ shape variations were evaluated for four (isotropic) margin concepts: two static PTVs (PTV 6mm and PTV 15mm ), a PTV based on ITV of the planning CT and CBCTs of the first treatment week (PTV ART ITV ) and an adaptive PTV based on a library approach (PTV ART Library ). Using static concepts, OAR doses increased with large margins, while smaller margins compromised target coverage. ART PTVs resulted in comparable target coverage and better sparing of bladder (V40Gy: 15% and 7% less), rectum (V40Gy: 18 and 6cc less) and bowel (V40Gy: 106 and 15cc less) compared to PTV 15mm . Target coverage evaluation showed that for elective fields a static 5mm margin sufficed. PTV ART Library achieved the best dosimetric results. However when weighing clinical benefit against workload, ITV margins based on repetitive movement evaluation during the first week also provide improvements over static margin concepts. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Vaccination coverage among children in kindergarten - United States, 2012-13 school year.
2013-08-02
State and local school vaccination requirements are implemented to maintain high vaccination coverage and minimize the risk from vaccine preventable diseases. To assess school vaccination coverage and exemptions, CDC annually analyzes school vaccination coverage data from federally funded immunization programs. These awardees include 50 states and the District of Columbia (DC), five cities, and eight U.S.-affiliated jurisdictions. This report summarizes vaccination coverage from 48 states and DC and exemption rates from 49 states and DC for children entering kindergarten for the 2012-13 school year. Forty-eight states and DC reported vaccination coverage, with medians of 94.5% for 2 doses of measles, mumps, and rubella (MMR) vaccine; 95.1% for local requirements for diphtheria, tetanus toxoid, and acellular pertussis (DTaP) vaccination; and 93.8% for 2 doses of varicella vaccine among awardees with a 2-dose requirement. Forty-nine states and DC reported exemption rates, with the median total of 1.8%. Although school entry coverage for most awardees was at or near national Healthy People 2020 targets of maintaining 95% vaccination coverage levels for 2 doses of MMR vaccine, 4 doses of DTaP† vaccine, and 2 doses of varicella vaccine, low vaccination and high exemption levels can cluster within communities, increasing the risk for disease. Reports to CDC are aggregated at the state level; however, local reporting of school vaccination coverage might be accessible by awardees. These local-level data can be used to create evidence-based health communication strategies to help parents understand the risks for vaccine-preventable diseases and the benefits of vaccinations to the health of their children and other kindergarteners.
Vaccination coverage among children in kindergarten - United States, 2013-14 school year.
Seither, Ranee; Masalovich, Svetlana; Knighton, Cynthia L; Mellerson, Jenelle; Singleton, James A; Greby, Stacie M
2014-10-17
State and local vaccination requirements for school entry are implemented to maintain high vaccination coverage and protect schoolchildren from vaccine-preventable diseases. Each year, to assess state and national vaccination coverage and exemption levels among kindergartners, CDC analyzes school vaccination data collected by federally funded state, local, and territorial immunization programs. This report describes vaccination coverage in 49 states and the District of Columbia (DC) and vaccination exemption rates in 46 states and DC for children enrolled in kindergarten during the 2013-14 school year. Median vaccination coverage was 94.7% for 2 doses of measles, mumps, and rubella (MMR) vaccine; 95.0% for varying local requirements for diphtheria, tetanus toxoid, and acellular pertussis (DTaP) vaccine; and 93.3% for 2 doses of varicella vaccine among those states with a 2-dose requirement. The median total exemption rate was 1.8%. High exemption levels and suboptimal vaccination coverage leave children vulnerable to vaccine-preventable diseases. Although vaccination coverage among kindergartners for the majority of reporting states was at or near the 95% national Healthy People 2020 targets for 4 doses of DTaP, 2 doses of MMR, and 2 doses of varicella vaccine, low vaccination coverage and high exemption levels can cluster within communities. Immunization programs might have access to school vaccination coverage and exemption rates at a local level for counties, school districts, or schools that can identify areas where children are more vulnerable to vaccine-preventable diseases. Health promotion efforts in these local areas can be used to help parents understand the risks for vaccine-preventable diseases and the protection that vaccinations provide to their children.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Yao; Chen, Josephine; Leary, Celeste I.
Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques.more » To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matney, J; Lian, J; Chera, B
2015-06-15
Introduction: Geometric uncertainties in daily patient setup can lead to variations in the planned dose, especially when using highly conformal techniques such as helical Tomotherapy. To account for the potential effect of geometric uncertainty, our clinical practice is to expand critical structures by 3mm expansion into planning risk volumes (PRV). The PRV concept assumes the spatial dose cloud is insensitive to patient positioning. However, no tools currently exist to determine if a Tomotherapy plan is robust to the effects of daily setup variation. We objectively quantified the impact of geometric uncertainties on the 3D doses to critical normal tissues duringmore » helical Tomotherapy. Methods: Using a Matlab-based program created and validated by Accuray (Madison, WI), the planned Tomotherapy delivery sinogram recalculated dose on shifted CT datasets. Ten head and neck patients were selected for analysis. To simulate setup uncertainty, the patient anatomy was shifted ±3mm in the longitudinal, lateral and vertical axes. For each potential shift, the recalculated doses to various critical normal tissues were compared to the doses delivered to the PRV in the original plan Results: 18 shifted scenarios created from Tomotherapy plans for three patients with head and neck cancers were analyzed. For all simulated setup errors, the maximum doses to the brainstem, spinal cord, parotids and cochlea were no greater than 0.6Gy of the respective original PRV maximum. Despite 3mm setup shifts, the minimum dose delivered to 95% of the CTVs and PTVs were always within 0.4Gy of the original plan. Conclusions: For head and neck sites treated with Tomotherapy, the use of a 3mm PRV expansion provide a reasonable estimate of the dosimetric effects of 3mm setup uncertainties. Similarly, target coverage appears minimally effected by a 3mm setup uncertainty. Data from a larger number of patients will be presented. Future work will include other anatomical sites.« less
Menegas, Damianos; Katsioulis, Antonis; Theodoridou, Maria; Kremastinou, Jenny; Hadjichristodoulou, Christos
2017-01-01
ABSTRACT Vaccination coverage studies are important in determining a population's vaccination status and strategically adjusting national immunization programs. This study assessed full and timely vaccination coverage of preschool children aged 2–3 y attending nurseries-kindergartens (N-K) nationwide at the socioeconomic crisis onset. Geographically stratified cluster sampling was implemented considering prefectures as strata and N-K as clusters. The N-K were selected by simple random sampling from the sampling frame while their number was proportional to the stratum size. In total, 185 N-K (response rate 93.9%) and 2539 children (response rate 81.5%) participated. Coverage with traditional vaccines for diphtheria-tetanus-pertussis, polio and measles-mumps-rubella was very high (>95%), followed by Haemophilus influenzae type b and varicella vaccines. Despite very high final coverage, delayed vaccination was observed for hepatitis B (48.3% completed by 12 months). Significant delay was observed for the booster dose of pneumococcal conjugate vaccines (PCV) and meningococcal C conjugate vaccines (MCC). Of the total population studied, 82.3% received 3 PCV doses by 12 months, while 62.3% received the fourth dose by 24 months and 76.2% by 30 months. However, 89.6% received at least one MCC dose over 12 months. Timely vaccinated for hepatitis A with 2 doses by 24 months were 6.1%. Coverage was significantly low for Rotavirus (<20%) and influenza (23.1% one dose). High vaccination coverage is maintained for most vaccines at the beginning of the crisis in Greece. Coverage and timeliness show an increasing trend compared to previous studies. Sustained efforts are needed to support the preventive medicine system as socioeconomic instability continues. PMID:27669156
Keall, Paul J; Colvill, Emma; O'Brien, Ricky; Caillet, Vincent; Eade, Thomas; Kneebone, Andrew; Hruby, George; Poulsen, Per R; Zwan, Benjamin; Greer, Peter B; Booth, Jeremy
2018-06-01
To report on the primary and secondary outcomes of a prospective clinical trial of electromagnetic-guided multileaf collimator (MLC) tracking radiation therapy for prostate cancer. Twenty-eight men with prostate cancer were treated with electromagnetic-guided MLC tracking with volumetric modulated arc therapy. A total of 858 fractions were delivered, with the dose per fraction ranging from 2 to 13.75 Gy. The primary outcome was feasibility, with success determined if >95% of fractions were successfully delivered. The secondary outcomes were (1) the improvement in beam-target geometric alignment, (2) the improvement in dosimetric coverage of the prostate and avoidance of critical structures, and (3) no acute grade ≥3 genitourinary or gastrointestinal toxicity. All 858 planned fractions were successfully delivered with MLC tracking, demonstrating the primary outcome of feasibility (P < .001). MLC tracking improved the beam-target geometric alignment from 1.4 to 0.90 mm (root-mean-square error). MLC tracking improved the dosimetric coverage of the prostate and reduced the daily variation in dose to critical structures. No acute grade ≥3 genitourinary or gastrointestinal toxicity was observed. Electromagnetic-guided MLC tracking radiation therapy for prostate cancer is feasible. The patients received improved geometric targeting and delivered dose distributions that were closer to those planned than they would have received without electromagnetic-guided MLC tracking. No significant acute toxicity was observed. Copyright © 2018 Elsevier Inc. All rights reserved.
Park, Boyoung; Lee, Yeon-Kyeng; Cho, Lisa Y.; Go, Un Yeong; Yang, Jae Jeong; Ma, Seung Hyun; Choi, Bo-Youl; Lee, Moo-Sik; Lee, Jin-Seok; Choi, Eun Hwa; Lee, Hoan Jong
2011-01-01
This study compared interview and telephone surveys to select the better method for regularly estimating nationwide vaccination coverage rates in Korea. Interview surveys using multi-stage cluster sampling and telephone surveys using stratified random sampling were conducted. Nationwide coverage rates were estimated in subjects with vaccination cards in the interview survey. The interview survey relative to the telephone survey showed a higher response rate, lower missing rate, higher validity and a less difference in vaccination coverage rates between card owners and non-owners. Primary vaccination coverage rate was greater than 90% except for the fourth dose of DTaP (diphtheria/tetanus/pertussis), the third dose of polio, and the third dose of Japanese B encephalitis (JBE). The DTaP4: Polio3: MMR1 fully vaccination rate was 62.0% and BCG1:HepB3:DTaP4:Polio3:MMR1 was 59.5%. For age-appropriate vaccination, the coverage rate was 50%-80%. We concluded that the interview survey was better than the telephone survey. These results can be applied to countries with incomplete registry and decreasing rates of landline telephone coverage due to increased cell phone usage and countries. Among mandatory vaccines, efforts to increase vaccination rate for the fourth dose of DTaP, the third dose of polio, JBE and regular vaccinations at recommended periods should be conducted in Korea. PMID:21655054
Hull, Brynley P; Menzies, Robert; Macartney, Kristine; McIntyre, Peter B
2013-04-08
Strict age limits for receipt of rotavirus vaccines and simultaneous use of vaccines requiring two (Rotarix(®)) and three (RotaTeq(®)) doses in Australia may impact on coverage and timeliness of other vaccines in the infant schedule. Using data from the Australian Childhood Immunisation Register (ACIR), coverage and timeliness of rotavirus vaccines and changes in timeliness of other infant vaccines following rotavirus vaccine introduction was examined, with particular emphasis on Indigenous infants in whom coverage is less optimal. Final dose rotavirus coverage reached 83% within 21 months of program commencement but remained 7% lower than other vaccines due in infancy. Coverage was 11-17% lower in Indigenous infants. Adherence to the first dose upper age limits for rotavirus vaccine was high with >97% of children vaccinated by the recommended age, but for subsequent rotavirus doses, receipt beyond the upper age limits was more common, especially in Indigenous children. Following rotavirus vaccine introduction, there were improvements in timeliness of receipt of all doses of DTPa-containing and 7-valent pneumococcal conjugate vaccines. High population coverage can be attained with rotavirus vaccines, even with adherence to strict upper age restrictions for vaccine dose administration. Rotavirus vaccine introduction appears to have impacted upon the timeliness of other concomitantly scheduled vaccines. These factors should be considered when rotavirus programs are introduced. Copyright © 2013 Elsevier Ltd. All rights reserved.
Benefits of adaptive radiation therapy in lung cancer as a function of replanning frequency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dial, Christian; Weiss, Elisabeth; Hugo, Geoffrey D., E-mail: gdhugo@vcu.edu
Purpose: To quantify the potential benefit associated with daily replanning in lung cancer in terms of normal tissue dose sparing and to characterize the tradeoff between adaptive benefit and replanning frequency. Methods: A set of synthetic images and contours, derived from weekly active breathing control images of 12 patients who underwent radiation therapy treatment for nonsmall cell lung cancer, is generated for each fraction of treatment using principal component analysis in a way that preserves temporal anatomical trends (e.g., tumor regression). Daily synthetic images and contours are used to simulate four different treatment scenarios: (1) a “no-adapt” scenario that simulatesmore » delivery of an initial plan throughout treatment, (2) a “midadapt” scenario that implements a single replan for fraction 18, (3) a “weekly adapt” scenario that simulates weekly adaptations, and (4) a “full-adapt” scenario that simulates daily replanning. An initial intensity modulated radiation therapy plan is created for each patient and replanning is carried out in an automated fashion by reoptimizing beam apertures and weights. Dose is calculated on each image and accumulated to the first in the series using deformable mappings utilized in synthetic image creation for comparison between simulated treatments. Results: Target coverage was maintained and cord tolerance was not exceeded for any of the adaptive simulations. Average reductions in mean lung dose (MLD) and volume of lung receiving 20 Gy or more (V20{sub lung}) were 65 ± 49 cGy (p = 0.000 01) and 1.1% ± 1.2% (p = 0.0006), respectively, for all patients. The largest reduction in MLD for a single patient was 162 cGy, which allowed an isotoxic escalation of the target dose of 1668 cGy. Average reductions in cord max dose, mean esophageal dose (MED), dose received by 66% of the heart (D66{sub heart}), and dose received by 33% of the heart (D33{sub heart}), were 158 ± 280, 117 ± 121, 37 ± 77, and 99 ± 120 cGy, respectively. Average incremental reductions in MLD for the midadapt, weekly adapt, and full-adapt treatments were 38, 18, and 8 cGy, respectively. Incremental reductions in MED for the same treatments were 57, 37, and 23 cGy. Reductions in MLD and MED for the full-adapt treatment were correlated with the absolute decrease in the planning target volume (r = 0.34 and r = 0.26). Conclusions: Adaptive radiation therapy for lung cancer yields clinically relevant reductions in normal tissue doses for frequencies of adaptation ranging from a single replan up to daily replanning. Increased frequencies of adaptation result in additional benefit while magnitude of benefit decreases.« less
Brotherton, Julia M L; Liu, Bette; Donovan, Basil; Kaldor, John M; Saville, Marion
2014-01-23
Accurate estimates of coverage are essential for estimating the population effectiveness of human papillomavirus (HPV) vaccination. Australia has a purpose built National HPV Vaccination Program Register for monitoring coverage, however notification of doses administered to young women in the community during the national catch-up program (2007-2009) was not compulsory. In 2011, we undertook a population-based mobile phone survey of young women to independently estimate HPV vaccination coverage. Randomly generated mobile phone numbers were dialed to recruit women aged 22-30 (age eligible for HPV vaccination) to complete a computer assisted telephone interview. Consent was sought to validate self reported HPV vaccination status against the national register. Coverage rates were calculated based on self report and weighted to the age and state of residence structure of the Australian female population. These were compared with coverage estimates from the register using Australian Bureau of Statistics estimated resident populations as the denominator. Among the 1379 participants, the national estimate for self reported HPV vaccination coverage for doses 1/2/3, respectively, weighted for age and state of residence, was 64/59/53%. This compares with coverage of 55/45/32% and 49/40/28% based on register records, using 2007 and 2011 population data as the denominators respectively. Some significant differences in coverage between the states were identified. 20% (223) of women returned a consent form allowing validation of doses against the register and provider records: among these women 85.6% (538) of self reported doses were confirmed. We confirmed that coverage rates for young women vaccinated in the community (at age 18-26 years) are underestimated by the national register and that under-notification is greater for second and third doses. Using 2011 population estimates, rather than estimates contemporaneous with the program rollout, reduces register-based coverage estimates further because of large population increases due to immigration since the program. Copyright © 2013 Elsevier Ltd. All rights reserved.
de Leeuw, Peter W; Fagard, Robert; Kroon, Abraham A
2017-06-01
This randomized, double-blind, parallel-group, multicenter study compared the efficacy of amlodipine and losartan in an older hypertensive population, focusing on therapeutic coverage in the case of missed doses. Following a 4-week, single-blind, placebo washout period, 211 patients were randomly assigned to receive either 5 mg of amlodipine once daily or 50 mg of losartan once daily. Doses were doubled after 6 weeks of treatment if the diastolic blood pressure exceeded 90 mm Hg. After the 12-week treatment period, patients received the placebo for 2 days (drug holiday) to simulate two missed doses of antihypertensive medication. Twenty-four-hour ambulatory blood pressure monitoring was conducted at the end of the placebo washout period (baseline), upon completion of the 12-week treatment period (steady state), and after the 2-day drug holiday. Amlodipine was more effective than losartan in reducing patients' 24-h ambulatory blood pressure at the steady-state sampling time. The increases in 24-h blood pressure during the drug holiday averaged 6±2/2±1 mm Hg (P<0.0001) in the amlodipine group and 3±2/2±1 mm Hg (P<0.0001) in the losartan group. The rise in systolic pressure was greater in patients on amlodipine than in those on losartan (P<0.0001). For diastolic pressure, the changes did not differ. Owing to the lower pressure during treatment, patients in the amlodipine group remained at a significantly lower blood pressure level after the 2-day drug holiday. Amlodipine was more effective than losartan in lowering blood pressure and in maintaining blood pressure control after two missed doses, and the difference was most significant for systolic blood pressure.
Lewis, Rayleen M; Markowitz, Lauri E
2018-05-03
Human papillomavirus (HPV) vaccination has been routinely recommended at age 11-12 years in the United States for females since 2006 and males since 2011. Coverage can be estimated using self/parent-reported HPV vaccination collected in the National Health and Nutrition Examination Survey (NHANES) for a wider age range than other national surveys. We assessed vaccination coverage in 2015-2016, temporal trends by age, and the validity of self/parent-reported vaccination status. Participants aged 9-59 years completed an interview collecting demographic and vaccination information. Weighted coverage was estimated for two-year NHANES cycles by age group for 2007-2008 to 2015-2016 for females (N = 14318) and 2011-2012 to 2015-2016 for males (N = 7847). Temporal trends in coverage were assessed from 2007-2008 to 2011-2012 for females and from 2011-2012 to 2015-2016 for both sexes. Sensitivity and specificity of self/parent-reported vaccination were assessed using provider-verified vaccination records from a pilot study in 14-29 year-olds. In 2015-2016, ≥1 dose coverage among females was highest in 14-19 (54.7%) and 20-24 (56.0%) year-olds and lower in successively older age groups. Among males, ≥1 dose coverage was highest in 14-19 year-olds (39.5%) and lower at older ages. Coverage was similar in 9-13 year-old females and males. Between 2007-2008 and 2011-2012, there were increases among females younger than 30 years. Between 2011-2012 and 2015-2016, there were increases among female age groups including 20-39 year-olds; male coverage increased among ages 9-13, 14-19, and 20-24 years. Self/parent-reported receipt of ≥1 dose had a sensitivity and specificity of 87.0% and 83.3%. Performance was lower for 3 doses. While overall HPV vaccination coverage remains low, it is higher in females than males, except in 9-13 year-olds. There have been increases in coverage among many age groups, but coverage has stalled in younger females. Adequate validity was demonstrated for self/parent-reported vaccination of ≥1 dose, but not 3 doses, in a pilot study. Copyright © 2018 Elsevier Ltd. All rights reserved.
An Evaluation of Voluntary Varicella Vaccination Coverage in Zhejiang Province, East China.
Hu, Yu; Chen, Yaping; Zhang, Bing; Li, Qian
2016-06-03
In 2014 a 2-doses varicella vaccine (VarV) schedule was recommended by the Zhejiang Provincial Center for Disease Control and Prevention. We aimed to assess the coverage of the 1st dose of VarV (VarV₁) and the 2nd dose of VarV (VarV₂) among children aged 2-6 years through the Zhejiang Provincial Immunization Information System (ZJIIS) and to explore the determinants associated with the VarV coverage. Children aged 2-6 years (born from 1 January 2009 to 31 December 2013) registered in ZJIIS were enrolled. Anonymized individual records of target children were extracted from the ZJIIS database on 1 January 2016, including their VarV and (measles-containing vaccine) MCV vaccination information. The VarV₁ and VarV₂ coverage rates were evaluated for each birth cohorts. The coverage of VarV also was estimated among strata defined by cities, gender and immigration status. We also evaluated the difference in coverage between VarV and MCV. A total of 3,028,222 children aged 2-6 years were enrolled. The coverage of VarV₁ ranged from 84.8% to 87.9% in the 2009-2013 birth cohorts, while the coverage of VarV₂ increased from 31.8% for the 2009 birth cohort to 48.7% for the 2011 birth cohort. Higher coverage rates for both VarV₁ and VarV₂ were observed among resident children in relevant birth cohorts. The coverage rates of VarV₁ and VarV₂ were lower than those for the 1st and 2nd dose of MCV, which were above 95%. The proportion of children who were vaccinated with VarV₁ at the recommended age increased from 34.6% for the 2009 birth cohort to 75.2% for the 2013 birth cohort, while the proportion of children who were vaccinated with VarV₂ at the recommended age increased from 19.7% for the 2009 birth cohort to 48.7% for the 2011 birth cohort. Our study showed a rapid increasing VarV₂ coverage of children, indicating a growing acceptance of the 2-doses VarV schedule among children's caregivers and physicians after the new recommendation released. We highlighted the necessity for a 2-doses VarV vaccination school-entry requirement to achieve the high coverage of >90% and to eliminate disparities in coverage among sub-populations. We also recommended continuous monitoring of the VarV coverage via ZJIIS over time.
Phasing out of the Universal Mega Dose of Vitamin-A Prophylaxis to Avoid Toxicity.
Bhattacharya, Sudip; Singh, Amarjeet
2017-01-01
Childhood blindness due to corneal ulceration was prevalent among poor Indian children. To tackle this situation, the National Institute of Nutrition (NIN), Hyderabad, India, Vitamin-A (Vit-A) prophylaxis programme was launched nationally in 1970 after field testing. Research of Indian Council for Medical Research (ICMR) documented that prevalence of Vit-A deficiency signs such as Bitot's spot decreased among children, over a period of time. However, this decrease cannot be ascertained is due to mass Vit-A prophylaxis programme. This is because coverage was low and patchy. Improved nutrition status, wider vaccination coverage, increased rate in breast feeding and improvement of healthcare services played a crucial role. Rather many studies revealed that (mass prophylaxis to the child who is having adequate Vit-A level) it may be harmful to certain group of children as a result of acute toxic symptoms. High dose of Vit-A is capable of loss of bone density-hence retarded growth may be observed in susceptible individuals. To tackle this issue food based approach should be promoted (which includes breast feeding) along with timely measles vaccination. The children who have signs of Vit-A deficiency (e.g. night blindness, xeropthalmia, Bitot's spot) or post measles children should receive Vit-A in age specific daily doses for two weeks along with Vit-A rich food, like green leafy vegetables, red palm oil, liver etc. Public spirited citizens, together with scientific community in India, should discourage this "one size fit to all" approach. It will not only avoid the ill effects of high dose of Vit-A but also it will help us optimal utilization of health resources in a resource poor country like India.
Braeckman, Tessa; Lernout, Tinne; Top, Geert; Paeps, Annick; Roelants, Mathieu; Hoppenbrouwers, Karel; Van Damme, Pierre; Theeten, Heidi
2014-01-09
Infant immunisation coverage in Flanders, Belgium, is monitored through repeated coverage surveys. With the increased use of Vaccinnet, the web-based ordering system for vaccines in Flanders set up in 2004 and linked to an immunisation register, this database could become an alternative to quickly estimate vaccination coverage. To evaluate its current accuracy, coverage estimates generated from Vaccinnet alone were compared with estimates from the most recent survey (2012) that combined interview data with data from Vaccinnet and medical files. Coverage rates from registrations in Vaccinnet were systematically lower than the corresponding estimates obtained through the survey (mean difference 7.7%). This difference increased by dose number for vaccines that require multiple doses. Differences in administration date between the two sources were observed for 3.8-8.2% of registered doses. Underparticipation in Vaccinnet thus significantly impacts on the register-based immunisation coverage estimates, amplified by underregistration of administered doses among vaccinators using Vaccinnet. Therefore, survey studies, despite being labour-intensive and expensive, currently provide more complete and reliable results than register-based estimates alone in Flanders. However, further improvement of Vaccinnet's completeness will likely allow more accurate estimates in the nearby future. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henke, Lauren; Kashani, Rojano; Yang, Deshan
Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day”more » (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.« less
Adaptive radiation therapy of prostate cancer
NASA Astrophysics Data System (ADS)
Wen, Ning
ART is a close-loop feedback algorithm which evaluates the organ deformation and motion right before the treatment and takes into account dose delivery variation daily to compensate for the difference between planned and delivered dose. It also has potential to allow further dose escalation and margin reduction to improve the clinical outcome. This retrospective study evaluated ART for prostate cancer treatment and radiobiological consequences. An IRB approved protocol has been used to evaluate actual dose delivery of patients with prostate cancer undergoing treatment with daily CBCT. The dose from CBCT was measured in phantom using TLD and ion chamber techniques in the pelvic scan setting. There were two major findings from the measurements of CBCT dose: (1) the lateral dose distribution was not symmetrical, with Lt Lat being ˜40% higher than Rt Lat and (2) AP skin dose varies with patient size, ranging 3.2--6.1 cGy for patient's AP separation of 20--33 cm (the larger the separation, the less the skin dose) but lateral skin doses depend little on separations. Dose was recalculated on each CBCT set under the same treatment plan. DIR was performed between SIM-CT and evaluated for each CT sets. Dose was reconstructed and accumulated to reflect the actual dose delivered to the patient. Then the adaptive plans were compared to the original plan to evaluate tumor control and normal tissue complication using radiobiological model. Different PTV margins were also studied to access margin reduction techniques. If the actual dose delivered to the PTV deviated significantly from the prescription dose for the given fractions or the OAR received higher dose than expected, the treatment plan would be re-optimized based on the previously delivered dose. The optimal schedule was compared based on the balance of PTV dose coverage and inhomogeneity, OAR dose constraints and labor involved. DIR was validated using fiducial marker position, visual comparison and UE. The mean and standard deviation of markers after rigid registration in L-R direction was 0 and 1 mm. But the mean was 2--4 mm in the A-P and S-I direction and standard deviation was about 2 mm. After DIR, the mean in all three directions became 0 and standard deviation was within sub millimeter. UE images were generated for each CT set and carefully reviewed in the prostate region. DIR provided accurate transformation matrix to be used for dose reconstruction. The delivered dose was evaluated with radiobiological models. TCP for the CTV was calculated to evaluate tumor control in different margin settings. TCP calculated from the reconstructed dose agreed within 5% of the value in the plan for all patients with three different margins. EUD and NTCP were calculated to evaluate reaction of rectum to radiation. Similar biological evaluation was performed for bladder. EUD of actual dose was 3%--9% higher than that of planned dose of patient 1--3, 11%--20% higher of patient 4--5. Smaller margins could not reduce late GU toxicity effectively since bladder complication was directly related to Dmax which was at the same magnitude in the bladder no matter which margin was applied. Re-optimization was performed at the 10th, 20th , 30th, and 40th fraction to evaluate the effectiveness to limit OAR dose while maintaining the target coverage. Reconstructed dose was added to dose from remaining fractions after optimization to show the total dose patient would receive. It showed that if the plan was re-optimized at 10th or 20th fraction, total dose to rectum and bladder were very similar to planned dose with minor deviations. If the plan was re-optimized at the 30th fraction, since there was a large deviation between reconstructed dose and planned dose to OAR, optimization could not limit the OAR dose to the original plan with only 12 fractions left. If the re-optimization was done at the 40th fraction, it was impossible to compensate in the last 2 fractions. Large deviations of total dose to bladder and rectum still existed while dose inhomogeneity to PTV was significantly increased due to hard constraints set in the optimization to reduce OAR dose. In summary, ART did not show improvements in TCP if the patient was setup with CBCT. However, EUD of rectum and bladder was increased significantly due to tissue deformation which varied daily. With the power of ART, margins added to the CTV could be further reduced to preserve critical organs surrounding the target. (Abstract shortened by UMI.)
ERIC Educational Resources Information Center
Barwis, Gail L.
A study examined the coverage of the scientific aspects of the atomic bomb in four representative newspapers (New York "Times," New York "Herald Tribune," Chicago "Daily Tribune," and Boston "Daily Globe") and in 14 general mass circulation magazines in the time period immediately following the dropping of the bomb. Among the conclusions of the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuetzer, K; Paessler, T; Valentini, C
Purpose: Retrospective calculation of the delivered proton dose in prostate cancer patients based on a unique dataset of daily CT images. Methods: Inter-fractional motion in prostate cancer patients treated at our proton facility is counteracted by water-filled endorectal ballon and bladder filling protocol. Typical plans (XiO, Elekta Instruments AB, Stockholm) for 74 Gy(RBE) sequential boost treatment in 37 fractions include two series of opposing lateral double-scattered proton beams covering the respective iCTV. Stability of fiducial markers and anatomy were checked in 12 patients by daily scheduled in-room control CT (cCT) after immobilization and positioning according to bony anatomy utilizing orthogonalmore » X-ray. In RayStation 4.6 (RaySearch Laboritories AB, Stockholm), all cCTs are delineated retrospectively and the treatment plans were recalculated on the planning CT and the registered cCTs. All fraction doses were accumulated on the planning CT after deformable registration. Parameters of delivered dose to iCTV (D98%>95%, D2%<107%), bladder (V75Gy<15%, V70Gy<25%, V65Gy<30%), rectum (V70Gy<10%, V50Gy<40%) and femoral heads (V50Gy<5%) are compared to those in the treatment plan. Intra-therapy variation is represented in DVH bands. Results: No alarming differences were observed between planned and retrospectively accumulated dose: iCTV constraints were met, except for one patient (D98%=94.6% in non-boosted iCTV). Considered bladder and femoral head values were below the limits. Rectum V70Gy was slightly exceeded (<11.3%) in two patients. First intra-therapy variability analysis in 4 patients showed no timedependent parameter drift, revealed strongest variability for bladder dose. In some fractions, iCTV coverage (D98%) and rectum V70Gy was missed. Conclusion: Double scattered proton plans are accurately delivered to prostate cancer patients due to fractionation effects and the applied precise positioning and immobilization protocols. As a result of rare interventions after daily 3D imaging of the first 12 patients, in-room CT frequency for prostate cancer patients was reduced. The presented study supports this decision. The authors acknowledge the German Federal Ministry for Education and Research for funding the High Precision Radiotherapy Group at the OncoRay - National Center for Radiation Research in Oncology (BMBF- 03Z1N51).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantin, Audrey; Gingras, Luc; Archambault, Louis, E-mail: louis.archambault@phy.ulaval.ca
Purpose: The movements of the prostate relative to the pelvic lymph nodes during intensity-modulated radiation therapy treatment can limit margin reduction and affect the protection of the organs at risk (OAR). In this study, the authors performed an analysis of three adaptive treatment strategies that combine information from both bony and gold marker registrations. The robustness of those treatments against the interfraction prostate movements was evaluated. Methods: A retrospective study was conducted on five prostate cancer patients with 7–13 daily cone-beam CTs (CBCTs). The clinical target volumes (CTVs) consisting of pelvic lymph nodes, prostate, and seminal vesicles as well asmore » the OARs were delineated on each CBCT and the initial CT. Three adaptive strategies were analyzed. Two of these methods relied on a two-step patient positioning at each fraction. First step: a bony registration was used to deliver the nodal CTV prescription. Second step: a gold marker registration was then used either to (1) complete the dose delivered to the prostate (complement); (2) or give almost the entire prescription to the prostate with a weak dose gradient between the targets to compensate for possible motions (gradient). The third method (COR) used a pool of precalculated plans based on images acquired at previous treatment fractions. At each new fraction, a plan is selected from that pool based on the daily position of prostate center-of-mass. The dosimetric comparison was conducted and results are presented with and without the systematic shift in the prostate position on the CT planning. The adaptive strategies were compared to the current clinical standard where all fractions are treated with the initial nonadaptive plan. Results: The minimum daily prostate D{sub 95%} is improved by 2%, 9%, and 6% for the complement, the gradient, and the COR approaches, respectively, compared to the nonadaptive method. The average nodal CTV D{sub 95%} remains constant across the strategies, except for the gradient approach where a reduction of 7% is observed. However, a correction of the systematic shift reduced the problem, and the adaptive strategies remain robust against the prostate movement across the fraction. The bladder V{sub 55Gy} is reduced by 35% on average for the adaptive strategies. Conclusions: Because they offer increased CTV coverage and OAR sparing, adaptive methods may be suitable candidates for simple and efficient adaptive treatment strategies for prostate cancer. Margin reduction and systematic error correction in the prostate position improve the protection of the OAR and the dose coverage. A cumulative dose to simulate a complete treatment would show real effects and allow a better comparison between each method.« less
Immunization coverage among Hispanic ancestry, 2003 National Immunization Survey.
Darling, Natalie J; Barker, Lawrence E; Shefer, Abigail M; Chu, Susan Y
2005-12-01
The Hispanic population is increasing and heterogeneous (Hispanic refers to persons of Spanish, Hispanic, or Latino descent). The objective was to examine immunization rates among Hispanic ancestry for the 4:3:1:3:3 series (> or = 4 doses diphtheria, tetanus toxoids, and pertussis vaccine; > or = 3 doses poliovirus vaccine; > or = 1 doses measles-containing vaccine; > or = 3 doses Haemophilus influenzae type b vaccine; and > or = 3 doses hepatitis B vaccine). The National Immunization Survey measures immunization coverage among 19- to 35-month-old U.S. children. Coverage was compared from combined 2001-2003 data among Hispanics and non-Hispanic whites using t-tests, and among Hispanic ancestry using a chi-square test. Hispanics were categorized as Mexican, Mexican American, Central American, South American, Puerto Rican, Cuban, Spanish Caribbean (primarily Dominican Republic), other, and multiple ancestry. Children of Hispanic ancestry increased from 21% in 1999 to 25% in 2003. These Hispanic children were less well immunized than non-Hispanic whites (77.0%, +/-2.1% [95% confidence interval] compared to 82.5%, +/-1.1% (95% CI) > in 2003). Immunization coverage did not vary significantly among Hispanics of varying ancestries (p=0.26); however, there was substantial geographic variability. In some areas, immunization coverage among Hispanics was significantly higher than non-Hispanic whites. Hispanic children were less well immunized than non-Hispanic whites; however, coverage varied notably by geographic area. Although a chi-square test found no significant differences in coverage among Hispanic ancestries, the range of coverage, 79.2%, +/-5.1% for Cuban Americans to 72.1%, +/-2.4% for Mexican descent, may suggest a need for improved and more localized monitoring among Hispanic communities.
Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Daniel J.; Michaletz-Lorenz, Martha; Goddu, S. Murty
2012-03-15
Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of themore » fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.« less
Inequalities in full immunization coverage: trends in low- and middle-income countries
Barros, Aluísio JD; Wong, Kerry LM; Johnson, Hope L; Pariyo, George; França, Giovanny VA; Wehrmeister, Fernando C; Victora, Cesar G
2016-01-01
Abstract Objective To investigate disparities in full immunization coverage across and within 86 low- and middle-income countries. Methods In May 2015, using data from the most recent Demographic and Health Surveys and Multiple Indicator Cluster Surveys, we investigated inequalities in full immunization coverage – i.e. one dose of bacille Calmette-Guérin vaccine, one dose of measles vaccine, three doses of vaccine against diphtheria, pertussis and tetanus and three doses of polio vaccine – in 86 low- or middle-income countries. We then investigated temporal trends in the level and inequality of such coverage in eight of the countries. Findings In each of the World Health Organization’s regions, it appeared that about 56–69% of eligible children in the low- and middle-income countries had received full immunization. However, within each region, the mean recorded level of such coverage varied greatly. In the African Region, for example, it varied from 11.4% in Chad to 90.3% in Rwanda. We detected pro-rich inequality in such coverage in 45 of the 83 countries for which the relevant data were available and pro-urban inequality in 35 of the 86 study countries. Among the countries in which we investigated coverage trends, Madagascar and Mozambique appeared to have made the greatest progress in improving levels of full immunization coverage over the last two decades, particularly among the poorest quintiles of their populations. Conclusion Most low- and middle-income countries are affected by pro-rich and pro-urban inequalities in full immunization coverage that are not apparent when only national mean values of such coverage are reported. PMID:27821882
Code of Federal Regulations, 2013 CFR
2013-01-01
... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Coverage. 610.304 Section 610.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Administrative Dismissals of Daily, Hourly, and Piecework Employees § 610.304 Coverage. This subpart applies to regular...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Coverage. 610.304 Section 610.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Administrative Dismissals of Daily, Hourly, and Piecework Employees § 610.304 Coverage. This subpart applies to regular...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Coverage. 610.304 Section 610.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Administrative Dismissals of Daily, Hourly, and Piecework Employees § 610.304 Coverage. This subpart applies to regular...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Coverage. 610.304 Section 610.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Administrative Dismissals of Daily, Hourly, and Piecework Employees § 610.304 Coverage. This subpart applies to regular...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Coverage. 610.304 Section 610.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Administrative Dismissals of Daily, Hourly, and Piecework Employees § 610.304 Coverage. This subpart applies to regular...
Holl, Katsiaryna; Sauboin, Christophe; Amodio, Emanuele; Bonanni, Paolo; Gabutti, Giovanni
2016-10-21
Varicella is a highly infectious disease with a significant public health and economic burden, which can be prevented with childhood routine varicella vaccination. Vaccination strategies differ by country. Some factors are known to play an important role (number of doses, coverage, dosing interval, efficacy and catch-up programmes), however, their relative impact on the reduction of varicella in the population remains unclear. This paper aims to help policy makers prioritise the critical factors to achieve the most successful vaccination programme with the available budget. Scenarios assessed the impact of different vaccination strategies on reduction of varicella disease in the population. A dynamic transmission model was used and adapted to fit Italian demographics and population mixing patterns. Inputs included coverage, number of doses, dosing intervals, first-dose efficacy and availability of catch-up programmes, based on strategies currently used or likely to be used in different countries. The time horizon was 30 years. Both one- and two-dose routine varicella vaccination strategies prevented a comparable number of varicella cases with complications, but two-doses provided broader protection due to prevention of a higher number of milder varicella cases. A catch-up programme in susceptible adolescents aged 10-14 years old reduced varicella cases by 27-43 % in older children, which are often more severe than in younger children. Coverage, for all strategies, sustained at high levels achieved the largest reduction in varicella. In general, a 20 % increase in coverage resulted in a further 27-31 % reduction in varicella cases. When high coverage is reached, the impact of dosing interval and first-dose vaccine efficacy had a relatively lower impact on disease prevention in the population. Compared to the long (11 years) dosing interval, the short (5 months) and medium (5 years) interval schedules reduced varicella cases by a further 5-13 % and 2-5 %, respectively. Similarly, a 10 % increase in first-dose efficacy (from 65 to 75 % efficacy) prevented 2-5 % more varicella cases, suggesting it is the least influential factor when considering routine varicella vaccination. Vaccination strategies can be implemented differently in each country depending on their needs, infrastructure and healthcare budget. However, ensuring high coverage remains the critical success factor for significant prevention of varicella when introducing varicella vaccination in the national immunisation programme.
Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S
2010-01-01
To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.
Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi
2012-01-01
Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.
Vaccination coverage survey in Dhaka District.
Khan, M N A; Rahman, M L; Awal Miah, A; Islam, M S; Musa, S A J M; Tofail, F
2005-08-01
A survey was conducted in Dhaka District to measure the level of routine immunization coverage of children (12-23 months), to assess the tetanus toxoid (TT) immunization coverage among mothers of children (12-23 month), to evaluate EPI program continuity (dropout rates) and quality (percent of Invalid doses, vaccination card availability etc.) For this purpose, a thirty cluster cross-sectional survey was conducted in October 2002 to assess the immunization coverage in Dhaka. In this survey 30 clusters were randomly selected from a list of villages in 63 Unions of Dhaka following probability proportion to size (PPS) sampling procedure. A total of 210 children was studied using pre-tested structured questionnaire. Descriptive statistics was employed using software SPSS package for data analysis. The study showed that the routine immunization coverage in Dhaka among children by 12 months of age by card + history was 97% for BCG, 97% for Diphtheria, Pertussis Tetanus (DPT 1) and Oral Polio Vaccine (OPV 1), 75% for DPT3 and OPV3 and 67% for measles. Sixty six percent of all children surveyed had received valid doses of all vaccines by 12 months (fully immunized child). Programme access as measured by crude DPT1 coverage was better in Keranigonj (97%). Vaccination cards retention rate for children was 84%. Invalid DPT (1,2 or 3) doses were given to 25% of vaccinated children; 18% of measles doses were invalid. Surprisingly, major cause for invalid doses were not due to early immunizations or due to card lost but for giving tick in the card, instead of writing a valid date. DPT1 and DPT3 and DPT1- Measles drop out rates were 5% and 13% respectively. Major reason parents gave for never vaccinating their children (zero dose children) was (43%), major reasons for incomplete vaccination was lack of knowledge regarding subsequent doses (46%). TT surveys were also conducted for mothers of the children surveyed for vaccination coverage (mothers between 15-49 year old). Valid TT 1-5 coverage by card+ history was 97%, 55%, 44%, 24% and 11%, respectively. Card retention rate for TT was 67%. The findings of this study revealed that access to child and TT immunizations were good. But high dropouts and invalid doses reduced these percentages of fully immunized child to 66%. Programmatic strategy must be undertaken to reduce the existing high dropout rate in both child and TT immunizations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Alexandra D., E-mail: Alexandra.Jensen@med.uni-heidelberg.de; Nill, Simeon; Huber, Peter E.
Purpose: To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. Methods and Materials: In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on themore » basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Results: Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. Conclusion: To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays.« less
Jensen, Alexandra D; Nill, Simeon; Huber, Peter E; Bendl, Rolf; Debus, Jürgen; Münter, Marc W
2012-02-01
To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on the basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays. Copyright © 2012 Elsevier Inc. All rights reserved.
Haas, Jigal; Zilberberg, Eran; Kedem, Alon; Dar, Shir; Orvieto, Raoul
2015-02-01
We aim to evaluate the IVF-ET outcome in patients receiving a high daily dose (300 IU) of gonadotropins during controlled ovarian hyperstimulation (COH) for IVF and to assess the role of increasing the daily dose to 450 IU on improving outcome. All consecutive women admitted to our IVF unit during an 11 year period who underwent COH consisting of daily gonadotropin dose of 300 IU were included in the study. The ovarian stimulation characteristics, number of oocytes retrieved, number of embryo transferred and pregnancy rate were assessed. We also evaluated the subsequent cycle, using daily gonadotropin doses of 450 IU, among those patients who did not conceive using the 300 IU daily gonadotropin dose. Nine hundred and forty-nine consecutive IVF cycles were evaluated. Patients who conceived using the daily gonadotropin dose of 300 IU (n = 133, 14% pregnancy rate) had significantly longer stimulation, yielded higher numbers of oocytes retrieved, fertilization rate and number of embryos transferred, compared to those who did not conceive. Moreover, while comparing IVF cycles using daily gonadotropin doses of 300 IU to 450 IU (n = 117), no in-between group differences were observed, except for significantly higher yields of oocytes retrieved. Moreover, cycles using daily gonadotropin doses of 450 IU resulted in a 7.7 live-birth rate. In poor responders undergoing COH with a daily gonadotropin dose of 300 IU, increasing the dose to 450 IU resulted in significantly higher oocyte yields and a reasonable live birth rate.
Dolan, Samantha B; MacNeil, Adam
2017-06-14
Third dose diphtheria tetanus pertussis (DTP3) administrative coverage is a commonly used indicator for immunization program performance, although studies have demonstrated data quality issues with administrative DTP3 coverage. It is possible that administrative coverage for DTP3 may be inflated more than for other antigens. To examine this, theory, we compiled immunization coverage estimates from recent country surveys (n=71) and paired these with corresponding administrative coverage estimates, by country and cohort year, for DTP3 and 4 other antigens. Median administrative coverage was higher than survey estimates of coverage for all antigens (median differences from 26 to 30%), however this difference was similar for DTP3 as for all other antigens. These findings were consistent when countries were stratified by income level and eligibility for Gavi funding. Our findings demonstrate that while country administrative coverage estimates tend to be higher than survey estimates, DTP3 administrative coverage is not inflated more than other antigens. Published by Elsevier Ltd.
Ohri, Nisha; Cordeiro, Peter G; Keam, Jennifer; Ballangrud, Ase; Shi, Weiji; Zhang, Zhigang; Nerbun, Claire T; Woch, Katherine M; Stein, Nicholas F; Zhou, Ying; McCormick, Beryl; Powell, Simon N; Ho, Alice Y
2012-10-01
To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses. Published by Elsevier Inc.
News Coverage of Child Sexual Abuse and Prevention, 2007-2009
ERIC Educational Resources Information Center
Mejia, Pamela; Cheyne, Andrew; Dorfman, Lori
2012-01-01
News media coverage of child sexual abuse can help policymakers and the public understand what must be done to prevent future abuse, but coverage tends to focus on extreme cases. This article presents an analysis of newspaper coverage from 2007 to 2009 to describe how the daily news presents and frames day-to-day stories about child sexual abuse.…
Proof of concept: performance testing in models.
Craig, W A
2004-04-01
Pharmacokinetic (PK) and pharmacodynamic (PD) principles that predict antimicrobial efficacy can be used to set targets for antimicrobial design and optimisation. Although current formulations of amoxicillin and amoxicillin/clavulanate have retained their efficacy against many, but not all, penicillin-nonsusceptible Streptococcus pneumoniae, additional coverage is required to address the growing problem of drug-resistant strains. Accordingly, two new oral formulations of amoxicillin/clavulanate, a paediatric formulation at 90/6.4 mg/kg/day and a pharmacokinetically enhanced formulation at 2000/125 mg twice daily for adults, were designed using PK/PD principles. These principles indicate that for amoxicillin and amoxicillin/clavulanate, a time above MIC of 35-40% of the dosing interval is predictive of high bacterial efficacy. In line with PK/PD predictions, simulation of human pharmacokinetics in in-vitro kinetic models and in a rat model of pneumonia, amoxicillin/clavulanate 2000/125 mg twice daily was highly effective against S. pneumoniae strains with amoxicillin MICs of 4 or 8 mg/L. Against strains with amoxicillin MICs of 4 mg/L, amoxicillin/clavulanate 2000/125 mg twice daily was significantly more effective than the conventional 875/125 mg twice daily formulation, azithromycin and levofloxacin, even though all levofloxacin MICs were < or = 1 mg/L. Following infection with S. pneumoniae strains with amoxicillin MICs of 8 mg/L, the amoxicillin/clavulanate 2000/125 mg twice daily formulation was more effective than the conventional amoxicillin/clavulanate formulations of 875/125 mg twice daily and three times daily and 1000/125 mg three times daily, and had similar or better efficacy than azithromycin and levofloxacin, depending on the strain. These data indicate the potential benefit of therapy with amoxicillin/clavulanate 2000/125 mg twice daily compared with conventional formulations and other marketed antimicrobials in the treatment of respiratory tract infection.
MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fredriksson, A
2016-06-15
Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selectedmore » as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.« less
Gram, Lu; Soremekun, Seyi; ten Asbroek, Augustinus; Manu, Alexander; O'Leary, Maureen; Hill, Zelee; Danso, Samuel; Amenga-Etego, Seeba; Owusu-Agyei, Seth; Kirkwood, Betty R
2014-07-01
To assess the extent of socio-economic inequity in coverage and timeliness of key childhood immunisations in Ghana. Secondary analysis of vaccination card data collected from babies born between January 2008 and January 2010 who were registered in the surveillance system supporting the ObaapaVita and Newhints Trials was carried out. 20 251 babies had 6 weeks' follow-up, 16 652 had 26 weeks' follow-up, and 5568 had 1 year's follow-up. We performed a descriptive analysis of coverage and timeliness of vaccinations by indicators for urban/rural status, wealth and educational attainment. The association of coverage with socio-economic indicators was tested using a chi-square-test and the association with timeliness using Cox regression. Overall coverage at 1 year of age was high (>95%) for Bacillus Calmette-Guérin (BCG), all three pentavalent diphtheria-pertussis-tetanus-haemophilus influenzae B-hepatitis B (DPTHH) doses and all polio doses except polio at birth (63%). Coverage against measles and yellow fever was 85%. Median delay for BCG was 1.7 weeks. For polio at birth, the median delay was 5 days; all other vaccine doses had median delays of 2-4 weeks. We found substantial health inequity across all socio-economic indicators for all vaccines in terms of timeliness, but not coverage at 1 year. For example, for the last DPTHH dose, the proportion of children delayed more than 8 weeks were 27% for urban children and 31% for rural children (P < 0.001), 21% in the wealthiest quintile and 41% in the poorest quintile (P < 0.001), and 9% in the most educated group and 39% in the least educated group (P < 0.001). However, 1-year coverage of the same dose remained above 90% for all levels of all socio-economic indicators. Ghana has substantial health inequity across urban/rural, socio-economic and educational divides. While overall coverage was high, most vaccines suffered from poor timeliness. We suggest that countries achieving high coverage should include timeliness indicators in their surveillance systems. © 2014 John Wiley & Sons Ltd.
Laar, Amos K
2010-12-01
This study assessed coverage of reproductive health (RH) issues--family planning (FP), abortion, and HIV--in the Ghanaian Daily Graphic newspaper. Using the composite week sampling technique, the researcher analyzed the contents of 62 editions of the paper. Prominence was measured using various attributes, and differences in mean coverage over time were assessed using analysis of variance. This review shows that coverage of RH issues was extraordinarily poor, less than 1 percent each for FP, abortion, and HIV. RH news that was covered was given little prominence. These findings support the popular impression that the Daily Graphic does not give priority to reproductive health issues in its coverage. RH advocates need to develop innovative means of integrating RH content into existing media outlets.
A novel dose-based positioning method for CT image-guided proton therapy
Cheung, Joey P.; Park, Peter C.; Court, Laurence E.; Ronald Zhu, X.; Kudchadker, Rajat J.; Frank, Steven J.; Dong, Lei
2013-01-01
Purpose: Proton dose distributions can potentially be altered by anatomical changes in the beam path despite perfect target alignment using traditional image guidance methods. In this simulation study, the authors explored the use of dosimetric factors instead of only anatomy to set up patients for proton therapy using in-room volumetric computed tomographic (CT) images. Methods: To simulate patient anatomy in a free-breathing treatment condition, weekly time-averaged four-dimensional CT data near the end of treatment for 15 lung cancer patients were used in this study for a dose-based isocenter shift method to correct dosimetric deviations without replanning. The isocenter shift was obtained using the traditional anatomy-based image guidance method as the starting position. Subsequent isocenter shifts were established based on dosimetric criteria using a fast dose approximation method. For each isocenter shift, doses were calculated every 2 mm up to ±8 mm in each direction. The optimal dose alignment was obtained by imposing a target coverage constraint that at least 99% of the target would receive at least 95% of the prescribed dose and by minimizing the mean dose to the ipsilateral lung. Results: The authors found that 7 of 15 plans did not meet the target coverage constraint when using only the anatomy-based alignment. After the authors applied dose-based alignment, all met the target coverage constraint. For all but one case in which the target dose was met using both anatomy-based and dose-based alignment, the latter method was able to improve normal tissue sparing. Conclusions: The authors demonstrated that a dose-based adjustment to the isocenter can improve target coverage and/or reduce dose to nearby normal tissue. PMID:23635262
Okolo, Chike; Malmstrom, Robert; Duncan, Karsten; Lopez, Julio
2015-09-01
Results of a study analyzing economic and clinical outcomes one year after conversion from thrice- to twice-daily pregabalin dosing for pain are presented. A retrospective chart review was conducted at two Veterans Affairs facilities. The analyzed population included all patients receiving pregabalin for pain whose dosing was converted from thrice- to twice-daily pregabalin dosing during a one-year period. The primary endpoint was the economic impact of the conversion. Secondary endpoints included reversion to thrice-daily pregabalin dosing, pregabalin discontinuation, addition of medications for pain, and unscheduled neuropathy-related visits. Among the 57 patients included in the data analysis, 41 continued to take pregabalin twice daily, 10 had pregabalin discontinued, and 6 had dosing reverted to thrice daily. The mean age of patients and the distribution of add-on pain medications did not differ significantly between patients whose pregabalin dosing frequency remained at twice daily and patients whose frequency reverted to thrice daily. The costs associated with pregabalin therapy differed significantly between the preconversion and postconversion periods. A savings of $115,867 was realized from this conversion for both facilities combined over the course of one year. In patients receiving pregabalin for pain, conversion from thrice- to twice-daily pregabalin dosing-while maintaining the same daily dose-resulted in substantial cost savings while having little effect on clinical outcomes. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Latsuzbaia, Ardashel; Arbyn, Marc; Weyers, Steven; Mossong, Joël
2018-04-25
In Luxembourg, a national Human Papillomavirus (HPV) vaccination programme was introduced in 2008, targeting 12-17 year old girls offering a choice of bivalent or quadrivalent vaccine free of charge. In 2015, the programme was changed offering the bivalent vaccine only to 11-13 year old girls. The aim of this study was to evaluate the HPV vaccination coverage, to assess the impact of age target changes and compare vaccination coverage to other European countries. Anonymous HPV vaccination records consisting of individual vaccine doses obtained free of charge in pharmacies between 2008 and 2016 were extracted from the Luxembourgish Social Security database. Additional aggregate tables by nationality and municipality were analysed. Of the target cohort of 39,610 girls born between 1991 and 2003 residing in Luxembourg, 24,550 (62.0%) subjects obtained at least one dose, 22,082 (55.7%) obtained at least two doses, and 17,197 (43.4%) obtained three doses of HPV vaccine. The mean age at first dose was 13.7 years during 2008-14 and 12.7 years in 2016 after the age target change. Coverage varied significantly by nationality (p < 0.0001): Portuguese (80%), former Yugoslavs (74%), Luxembourgish (54%), Belgian (52%), German (47%), French (39%) and other nationalities (51%). Coverage varied also by geographical region, with lower rates (<50%) noted in some Northern and Central areas of Luxembourg (range: 38% to 78%). Overall HPV vaccination coverage in Luxembourg is moderate and varied by nationality and region. The policy changes in 2015 did not have a substantial impact except lowering age at initiating vaccination. Options to improve coverage deserve further investigation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
van Hoek, Albert Jan; Melegaro, Alessia; Zagheni, Emelio; Edmunds, W John; Gay, Nigel
2011-03-16
This study updates previous work on modelling the incidence of varicella and Herpes Zoster (HZ) following the introduction of childhood vaccination. The updated model includes new data on age-specific contact patterns, as well as data on the efficacy of zoster vaccination in the elderly and allows for HZ among vaccinees. The current study also looks at two-dose varicella childhood programmes, and assesses the combined impact of varicella vaccination in childhood and zoster vaccination of the elderly. The results suggest that a two-dose schedule is likely to reduce the incidence of varicella to very low levels, provided first dose coverage is around 90% and second dose coverage is in excess of 70%. Single dose varicella vaccination programmes are expected to result in large numbers of breakthrough cases. Childhood vaccination is expected to increase the incidence of zoster for more than 40 years after introduction of the programme, the magnitude of this increase being influenced primarily by the duration of boosting following exposure to the varicella zoster virus. Though this increase in zoster incidence can be partly offset by vaccination of the elderly, the effectiveness of this combined strategy is limited, as much of the increase occurs in those adults too young to be vaccinated. Childhood vaccination at intermediate levels of coverage (70% and 60% for first and second dose coverage respectively) is expected to lead to an increase in adult varicella. At high coverage (90% and 80% coverage) this is unlikely to be the case. These results will be used to inform a cost-effectiveness analysis of combined varicella and zoster vaccination programmes. Copyright © 2011 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Coverage. 610.101 Section 610.101 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Weekly and Daily Scheduling of Work § 610.101 Coverage. This subpart applies to each employee to whom subpart A of part 550...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Coverage. 610.101 Section 610.101 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Weekly and Daily Scheduling of Work § 610.101 Coverage. This subpart applies to each employee to whom subpart A of part 550...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Coverage. 610.101 Section 610.101 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Weekly and Daily Scheduling of Work § 610.101 Coverage. This subpart applies to each employee to whom subpart A of part 550...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Coverage. 610.101 Section 610.101 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Weekly and Daily Scheduling of Work § 610.101 Coverage. This subpart applies to each employee to whom subpart A of part 550...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Coverage. 610.101 Section 610.101 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS HOURS OF DUTY Weekly and Daily Scheduling of Work § 610.101 Coverage. This subpart applies to each employee to whom subpart A of part 550...
Palache, A; Abelin, A; Hollingsworth, R; Cracknell, W; Jacobs, C; Tsai, T; Barbosa, P
2017-08-24
There is no global monitoring system for influenza vaccination coverage, making it difficult to assess progress towards the 2003 World Health Assembly (WHA) vaccination coverage target. In 2008, the IFPMA Influenza Vaccine Supply International Task Force (IVS) developed a survey method to assess the global distribution of influenza vaccine doses as a proxy for vaccination coverage rates. The latest dose distribution data for 2014 and 2015 was used to update previous analyses. Data were confidentially collected and aggregated by the IFPMA Secretariat, and combined with previous IFPMA IVS survey data (2004-2013). Data were available from 201 countries over the 2004-2015 period. A "hurdle" rate was defined as the number of doses required to reach 15.9% of the population in 2008. Overall, the number of distributed doses progressively increased between 2004 and 2011, driven by a 150% increase in AMRO, then plateaued. One percent fewer doses were distributed in 2015 than in 2011. Twenty-three countries were above the hurdle rate in 2015, compared to 15 in 2004, but distribution was highly uneven in and across all WHO regions. Three WHO regions (AMRO, EURO and WPRO) accounted for about 95% of doses distributed. But in EURO and WPRO, distribution rates in 2015 were only marginally higher than in 2004, and in EURO there was an overall downward trend in dose distribution. The vast majority of countries cannot meet the 2003WHA coverage targets and are inadequately prepared for a global influenza pandemic. With only 5% of influenza vaccine doses being distributed to 50% of the world's population, there is urgency to redress the gross inequities in disease prevention and in pandemic preparedness. The 2003WHA resolution must be reviewed and revised and a call issued for the renewed commitment of Member States to influenza vaccination coverage targets. Copyright © 2017. Published by Elsevier Ltd.
Tauil, Márcia de Cantuária; Sato, Ana Paula Sayuri; Costa, Ângela Aparecida; Inenami, Marta; Ferreira, Vinícius Leati de Rossi; Waldman, Eliseu Alves
2017-01-01
to describe vaccine coverage by type of vaccine at 12 and 24 months of age. descriptive cohort study with children born in 2012, living in Araraquara-SP, Brazil, recorded in the Information System on Live Births (Sinasc); a manual linkage of Sinasc data with an electronic immunization registry (EIR) was performed; the assessment was based on vaccination status according to São Paulo State recommendations, and on doses received and timely administered. 2,740 children were registered on Sinasc and 99.6% of them were included into EIR; among the 2,612 (95.3%) children studied, the triple viral vaccine (measles, mumps and rubella) had the lowest coverage at 12 months for received dose (74.8%) and at 24 months for timely vaccination (53.5%) and received doses (88.0%). coverage was higher than 90% for most vaccines; however, delayed vaccination was observed, which indicates the need to intensify actions aimed at timely vaccination.
Ford, Alexander C; Khan, Khurram J; Sandborn, William J; Kane, Sunanda V; Moayyedi, Paul
2011-12-01
Maintenance therapy with 5-aminosalicylates (5-ASAs) is recommended in patients with quiescent ulcerative colitis (UC), but compliance rates are low. Once-daily dosing may improve adherence, but impact on the relapse of disease activity is unclear as no previous meta-analysis has studied this issue. MEDLINE, EMBASE, and the Cochrane central register of controlled trials were searched (through April 2011). Eligible randomized controlled trials (RCTs) recruited adults with quiescent UC, and compared once-daily dosing of 5-ASAs with a more frequent dosing schedule of an identical total daily dose of the same 5-ASA drug. Minimum treatment duration was 6 months. Trials reported a dichotomous assessment of relapse of disease activity at last point of follow-up. Data concerning non-compliance and adverse events were extracted, where reported. Effect of once-daily vs. more frequent dosing schedule was reported as relative risk (RR) of relapse with a 95% confidence interval (CI). The search identified 3,061 citations, and seven RCTs containing 2,745 patients were eligible. All RCTs used mesalamine. Relapse rates were not significantly different between once-daily and conventional dosing schedules for mesalamine (RR of relapse=0.94; 95% CI: 0.82-1.08). Non-compliance (RR=0.87; 95% CI: 0.46-1.66) and adverse events were no more likely with once-daily dosing (RR=1.08; 95% CI: 0.97-1.20). Once-daily dosing with mesalamine is as effective as conventional dosing schedules for the prevention of relapse of quiescent UC, although there is no definitive evidence that compliance with once-daily dosing is better. Adverse events occur at a similar frequency.
Clements, C John; Soakai, Taniela Sunia; Sadr-Azodi, Nahad
2017-02-01
Standard measles control strategies include achieving high levels of measles vaccine coverage using routine delivery systems, supplemented by mass immunization campaigns as needed to close population immunity gaps. Areas covered: This review looks at how supplementary immunization activities (SIAs) have contributed to measles control globally, and asks whether such a strategy has a place in Pacific Islands today. Expert commentary: Very high coverage with two doses of measles vaccine seems to be the optimal strategy for controlling measles. By 2015, all but two Pacific Islands had introduced a second dose in the routine schedule; however, a number of countries have not yet reached high coverage with their second dose. The literature and the country reviews reported here suggest that a high coverage SIA combined with one dose of measles vaccine given in the routine system will also do the job. The arguments for and against the use of SIAs are complex, but it is clear that to be effective, SIAs need to be well designed to meet specific needs, must be carried out effectively and safely with very high coverage, and should, when possible, carry with them other public health interventions to make them even more cost-effective.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Islam, M; Algan, O; Jin, H
Purpose: To investigate the plan quality and feasibility of a hybrid plan utilizing proton and photon fields for superior coverage in the internal mammary (IM) and supraclavicular (S/C) regions while minimizing heart and contralateral breast dose for the left-sided whole breast cancer patient treatment. Methods: This preliminary study carried out on single left-sided intact breast patient involved IM and S/C nodes. The IM and S/C node fields of the 5-Field 3DCRT photon-electron base plan were replaced by two proton fields. These two along with two Field-in-Field tangential photon fields were optimized for comparable dose coverage. The treatment plans were donemore » using Eclipse TPS for the total dose of 46Gy in 23 fractions with 95% of the prescription dose covering 95% of the RTOG PTV. The 3DCRT photon-electron and 4-Field photon-proton hybrid plans were compared for the PTV dose coverage as well as dose to OARs. Results: The overall RTOG PTV coverage for proton-hybrid and 3DCRT plan was comparable (95% of prescription dose covers 95% PTV volume). In proton-hybrid plan, 99% of IM volume received 100% dose whereas in 3DCRT only 77% received 100% dose. For S/C regions, 97% and 77% volume received 100% prescription dose in proton-hybrid and 3DCRT plans, respectively. The heart mean dose, V3Gy(%), and V5Gy(%) was 2.2Gy, 14.4%, 9.8% for proton-hybrid vs. 4.20 Gy, 21.5%, and 39% for 3DCRT plan, respectively. The maximum dose to the contralateral breast was 39.75Gy for proton-hybrid while 56.87Gy for 3DCRT plan. The mean total lung dose, V20Gy(%), and V30Gy(%) was 5.68Gy, 11.3%, 10.5% for proton-hybrid vs. 5.90Gy, 9.8%, 7.2% for 3DCRT, respectively. Conclusion: The protonhybrid plan can offer better dose coverage to the involved lymphatic tissues while lower doses to the heart and contralateral breast. More treatment plans are currently in progress before being implemented clinically.« less
Comparison of twice-daily vs once-daily deferasirox dosing in a gerbil model of iron cardiomyopathy
Otto-Duessel, Maya; Aguilar, Michelle; Nick, Hanspeter; Moats, Rex; Wood, John C.
2010-01-01
Objective Despite the availability of deferoxamine chelation therapy for more than 20 years, iron cardiomyopathy remains the leading cause of death in thalassemia major patients. Effective chelation of cardiac iron is difficult; cardiac iron stores respond more slowly to chelation therapy and require a constant gradient of labile iron species between serum and myocytes. We have previously demonstrated the efficacy of once-daily deferasirox in removing previously stored cardiac iron in the gerbil, but changes in cardiac iron were relatively modest compared with hepatic iron. We postulated that daily divided dosing, by sustaining a longer labile iron gradient from myocytes to serum, would produce better cardiac iron chelation than a comparable daily dose. Methods Twenty-four 8- to 10-week-old female gerbils underwent iron dextran—loading for 10 weeks, followed by a 1-week iron equilibration period. Animals were divided into three treatment groups of eight animals each and were treated with deferasirox 100 mg/kg/day as a single dose, deferasirox 100 mg/kg/day daily divided dose, or sham chelation for a total of 12 weeks. Following euthanasia, organs were harvested for quantitative iron and tissue histology. Results Hepatic and cardiac iron contents were not statistically different between the daily single-dose and daily divided-dose groups. However, the ratio of cardiac to hepatic iron content was lower in the divided-dose group (0.78% vs 1.11%, p = 0.0007). Conclusion Daily divided dosing of deferasirox changes the relative cardiac and liver iron chelation profile compared with daily single dosing, trading improvements in cardiac iron elimination for less-effective hepatic chelation. PMID:17588475
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, Imad, E-mail: iali@ouhsc.edu; Ahmad, Salahuddin
2013-10-01
To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatmentmore » sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Runqing; Zhan, Lixin; Osei, Ernest
2016-08-15
Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinFmore » plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dellamonica, D.; Luo, G.; Ding, G.
Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less
Evaluation of a poliomyelitis immunization campaign in Madras city.
Balraj, V; John, T J
1986-01-01
An annual pulse immunization campaign with oral polio vaccine (OPV) was evaluated to determine vaccine coverage, relative success of publicity methods and reasons for lack of response. The campaign was directed at 3-36 month olds in Madras city, India, in January-March 1985. The evaluation method was the "30-cluster" sample survey technique, designed by WHO, where surveys were done in 30 districts of the city on 10 children in each age group. The survey was conducted in April 1985 by 5 trained and supervised interviewers. This campaign increased the vaccine coverage to 94%, 88% and 72% for first, second and third doses of OPV. Coverage was higher in older children. Percent coverage decreased slightly over 1-3 doses, and from there rapidly up to 6-7 doses. The campaign accounted for 27% of all the OPV the study children had received. 47% of parents heard about the vaccination through word of mouth, either from health workers, volunteers or "balwadi ayahs," women day-care workers. 17% learned through television or radio. 3% cited mobile loudspeakers, handbills, posters or slides in cinemas. Many parents did not avail themselves of the vaccine because they believed that 3 doses are sufficient. Actually the WHO recommends 4 doses; the Indian Academy of Pediatrics recommends 5 doses; while criteria from research on Indian children would suggest that 5-7 doses are required to raise strong immunity.
Newspaper Coverage of Biological Subissues in the Spotted Owl Debate, 1989-1993.
ERIC Educational Resources Information Center
Furlow, F. Bryant
1994-01-01
Computer archives for 27 U.S. daily newspapers were accessed to evaluate the levels of coverage for 5 biological subissues and 5 ecological concepts in articles on the spotted owl debate. The author identified a correlation between biologist/reporter contact and increased biological subissue and ecological concepts coverage. (LZ)
2016-01-01
Objectives. This study evaluated the impact of private insurance coverage on the symptoms of depression, activities of daily living (ADLs), and instrumental activities of daily living (IADLs) in the years leading up to Medicare eligibility focusing on the transition from full-time work to early full retirement. Method. The Health and Retirement Study was used to (a) estimate 2-stage selection equations of (i) the transition to retirement and (ii) current insurance status, and (b) the impact of insurance coverage on health, net of endogeneity associated retirement and insurance coverage. Results. Employment-based insurance coverage was generally associated with better health. Moreover, being without employment-based insurance was particularly problematic during the transition to retirement. Non-group insurance only moderated the association between losing employment-based insurance and IADLs. Discussion. Results indicated that private insurance coverage is an important contextual factor for the health of early retirees. Those who maintain steady coverage tend to fare the best in retirement. This highlights the dynamic nature of changes in health in later life. PMID:25819976
Immunization rates and timely administration in pre-school and school-aged children.
Heininger, Ulrich; Zuberbühler, Mirjam
2006-02-01
Whereas immunization coverage has been repeatedly assessed in the Swiss population, little is known about the timely administration of universally recommended immunizations in Switzerland and elsewhere. The goal of this study was to determine compliance with official standard immunization recommendations in pre-school and school-aged children in Basel, Switzerland, focusing on coverage rates and timely administration. Of a cohort of children entering kindergarten and third-grade primary school in Basel in 2001, 310 and 310, respectively, were identified in proportion to the overall age-appropriate populations in the four city districts. Foreign-born children were excluded. The data were extracted from immunization records provided voluntarily by parents. Coverage for three doses of diphtheria, tetanus, and poliomyelitis vaccines was >95% and <90% for pertussis and Hib. The rates of age-appropriate booster doses were significantly lower, especially for pertussis and Hib (<60%). Cumulative coverage for measles, mumps, and rubella (MMR) was <90% for the first dose and 33% for the second dose by 10 years of age. All immunizations were administered with significant delays. Coverage for the first three doses of DTP combination vaccines did not reach 90% before 1 year of age and, for the first dose of MMR, a plateau just below 80% was not reached before 3 years of age. Delayed administration of immunizations in childhood, as well as complete lack of booster doses in a significant fraction of children, with important implications for public health have been discovered in this study. This may lead to fatal disease in individuals, epidemics in the community, and threatens national and international targets of disease elimination, such as measles and congenital rubella syndrome.
Easton, Jane; Noble, Stuart; Perry, Caroline M
2003-01-01
Amoxicillin/clavulanic acid (Augmentin), Augmentin ES-600 is a well established, orally administered combination of amoxicillin (a semisynthetic antibacterial agent) and clavulanic acid (a beta-lactamase inhibitor). Amoxicillin/clavulanic acid shows good activity against the main pathogens associated with acute otitis media (AOM), including penicillin-susceptible and -intermediate strains of Streptococcus pneumoniae, and beta-lactamase producing strains of Haemophilus influenzae and Moraxella catarrhalis. It has moderate activity against penicillin-resistant S. pneumoniae; a high-dose formulation has been developed with the aim of providing better coverage for penicillin-resistant strains. Amoxicillin/clavulanic acid (conventional formulations, mostly 40/10 mg/kg/day in three divided doses) produced clinical response rates similar to those of oral cephalosporin comparators and similar to or significantly greater than those for intramuscular ceftriaxone in randomised trials in paediatric patients with AOM (mean age approximately 2 to 5 years). Clinical response rates were generally similar for amoxicillin/clavulanic acid and macrolide comparators (mean patient age approximately 1 to 6 years), although significantly better clinical and bacteriological responses were seen versus azithromycin in one randomised trial (mean patient age approximately 1 year). The high-dose formulation of amoxicillin/clavulanic acid (90/6.4 mg/kg/day in two divided doses) eradicated a high proportion of penicillin-resistant S. pneumoniae (penicillin MICs 2 or 4 mg/L) in a large noncomparative trial in children with AOM (upper limit of the US indication for S. pneumoniae is 2 mg/L). Amoxicillin/clavulanic acid is generally well tolerated. A low total incidence of adverse events (3.6%) and no serious events were reported from a large paediatric postmarketing study. The most frequently reported adverse events in children are mild gastrointestinal disturbances. Diarrhoea is generally less frequent with twice-daily than with three-times-daily treatment. The new high-dose formulation showed similar tolerability to a conventional twice-daily formulation (45/6.4 mg/kg/day) in a well controlled trial. Amoxicillin/clavulanic acid is a well established broad-spectrum antibacterial treatment which is effective and well tolerated in the treatment of AOM in paediatric patients. The high-dose combination should prove valuable in treating AOM caused by penicillin-intermediate and -resistant S. pneumoniae (approved in the US for penicillin MIC < or =2 mg/L). Based on recent recommendations and the available data, high-dose amoxicillin/clavulanic acid can be considered a treatment of choice for recurrent or persistent paediatric AOM (after failure of amoxicillin alone) where involvement of resistant pathogens is suspected.
Operational surface UV radiation product from GOME-2 and AVHRR/3 data
NASA Astrophysics Data System (ADS)
Kujanpää, J.; Kalakoski, N.
2015-05-01
The surface ultraviolet (UV) radiation product, version 1.20, generated operationally in the framework of the Satellite Application Facility on Ozone and Atmospheric Chemistry Monitoring (O3M SAF) of the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT) is described. The product is based on the total ozone column derived from the measurements of the second Global Ozone Monitoring Experiment (GOME-2) instrument aboard EUMETSAT's polar orbiting meteorological operational (Metop) satellites. The input total ozone product is generated by the German Aerospace Center (DLR) also within the O3M SAF framework. Polar orbiting satellites provide global coverage but infrequent sampling of the diurnal cloud cover. The diurnal variation of the surface UV radiation is extremely strong due to modulation by solar elevation and rapidly changing cloud cover. At the minimum, one sample of the cloud cover in the morning and another in the afternoon are needed to derive daily maximum and daily integrated surface UV radiation quantities. This is achieved by retrieving cloud optical depth from the channel 1 reflectance of the third Advanced Very High Resolution Radiometer (AVHRR/3) instrument aboard both Metop in the morning orbit (daytime descending node around 09:30 LT) and Polar Orbiting Environmental Satellites (POES) of the National Oceanic and Atmospheric Administration (NOAA) in the afternoon orbit (daytime ascending node around 14:30 LT). In addition, more overpasses are used at high latitudes where the swaths of consecutive orbits overlap. The input satellite data are received from EUMETSAT's Multicast Distribution System (EUMETCast) using commercial telecommunication satellites for broadcasting the data to the user community. The surface UV product includes daily maximum dose rates and integrated daily doses with different biological weighting functions, integrated UVB and UVA radiation, solar noon UV Index and daily maximum photolysis frequencies of ozone and nitrogen dioxide at the surface level. The quantities are computed in a 0.5° × 0.5° regular latitude-longitude grid and stored as daily files in the hierarchical data format (HDF5) within two weeks from sensing. The product files are archived in the O3M SAF distributed archive and can be ordered via the EUMETSAT Data Centre.
Combined online and offline adaptive radiation therapy: a dosimetric feasibility study.
Yang, Chengliang; Liu, Feng; Ahunbay, Ergun; Chang, Yu-Wen; Lawton, Colleen; Schultz, Christopher; Wang, Dian; Firat, Selim; Erickson, Beth; Li, X Allen
2014-01-01
The purpose of this work is to explore a new adaptive radiation therapy (ART) strategy, combined "online and offline" ART, that can fully account for interfraction variations similar to the existing online ART but with substantially reduced online effort. The concept for the combined ART is to perform online ART only for the fractions with obvious interfraction variations and to deliver the ART plan for that online fraction as well as the subsequent fractions until the next online fraction needs to be adapted. To demonstrate the idea, the daily computed tomographic (CT) data acquired during image guided radiation therapy (IGRT) with an in-room CT (CTVision, Siemens Healthcare, Amarillo, TX) for 6 representative patients (including 2 prostate, 1 head-and-neck, and 1 pancreatic cancer, 1 adrenal carcinoma, and 1 craniopharyngioma patients) were analyzed. Three types of plans were generated based on the following selected daily CTs: (1) IGRT repositioning plan, generated by applying the repositioning shifts to the original plan (representing the current IGRT practice); (2) Re-Opt plan, generated with full-scope optimization; and (3) ART plan, either online ART plan generated with an online ART tool (RealArt, Prowess Inc, Concord, CA) or offline ART plan generated with shifts from the online ART plan. Various dose-volume parameters were compared with measure dosimetric benefits of the ART plans based on daily dose distributions and the cumulative dose maps obtained with deformable image registration. In general, for all the cases studied, the ART (with 3-5 online ART) and Re-Opt plans provide comparable plan quality and offer significantly better target coverage and normal tissue sparing when compared with the repositioning plans. This improvement is statistically significant. The combined online and offline ART is dosimetrically equivalent to the online ART but with substantially reduced online effort, and enables immediate delivery of the adaptive plan when an obvious anatomic change is observed. Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duffy, Olivia; Forde, Elizabeth; Leech, Michelle, E-mail: leechm@tcd.ie
With margin reduction common in head and neck radiotherapy, it is critical that the dosimetric effects of setup deviations are quantified. With past studies focusing on the quantification of positional and volumetric changes of organs at risk (OARs), this study aimed to measure the dose delivered to these the parotid gland (PG) and pharyngeal constrictor muscles (PCMs) using cone beam computed tomography (CBCT). Furthermore, this investigation sought to establish a potential time trend of change in dose delivered to target volumes secondary to ascertaining the need for daily image guidance (IG) to reduce the dose burden to these important OARs.more » Intensity modulated radiotherapy (IMRT) plans for 5 locally advanced head and neck patients' plans were created and mapped to weekly CBCTs. Each plan was recalculated without heterogeneity correction allowing for dosimetric comparison. Dosimetric endpoints recorded to assess the effect of positional variation were as per ICRU 83 and included D{sub 95} and D{sub 98} for the target volumes, mean dose (MD) and V{sub 30} {sub Gy} for the PGs, and V{sub 50} {sub Gy} and MD for the PCMs. Results were deemed statistically significant if p < 0.05. No significant time trends were established for these OARs. A significant decrease in V{sub 50} {sub Gy} was observed for all PCMs (p < 0.001) on all CBCTs relative to the original plan. Regarding target volumes, a highly significant decrease in MD (MD = 20 Gy, CI: −20.310 to −19.820) in D{sub 98} of the high-dose planning target volume (PTV [70 Gy]; PTVD{sub 98%} = 70 Gy) for case 3 was found (p ≤ 0.001). A nonpredictable, yet significant dosimetric effect was found. A clinically acceptable balance must be achieved between OAR dosimetry and target coverage as can be achieved by frequent IG.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balik, S; Weiss, E; Sleeman, W
Purpose: To evaluate the potential impact of several setup error correction strategies on a proposed image-guided adaptive radiotherapy strategy for locally advanced lung cancer. Methods: Daily 4D cone-beam CT and weekly 4D fan-beam CT images were acquired from 9 lung cancer patients undergoing concurrent chemoradiation therapy. Initial planning CT was deformably registered to daily CBCT images to generate synthetic treatment courses. An adaptive radiation therapy course was simulated using the weekly CT images with replanning twice and a hypofractionated, simultaneous integrated boost to a total dose of 66 Gy to the original PTV and either a 66 Gy (no boost)more » or 82 Gy (boost) dose to the boost PTV (ITV + 3mm) in 33 fractions with IMRT or VMAT. Lymph nodes (LN) were not boosted (prescribed to 66 Gy in both plans). Synthetic images were rigidly, bony (BN) or tumor and carina (TC), registered to the corresponding plan CT, dose was computed on these from adaptive replans (PLAN) and deformably accumulated back to the original planning CT. Cumulative D98% of CTV of PT (ITV for 82Gy) and LN, and normal tissue dose changes were analyzed. Results: Two patients were removed from the study due to large registration errors. For the remaining 7 patients, D98% for CTV-PT (ITV-PT for 82 Gy) and CTV-LN was within 1 Gy of PLAN for both 66 Gy and 82 Gy plans with both setup techniques. Overall, TC based setup provided better results, especially for LN coverage (p = 0.1 for 66Gy plan and p = 0.2 for 82 Gy plan, comparison of BN and TC), though not significant. Normal tissue dose constraints violated for some patients if constraint was barely achieved in PLAN. Conclusion: The hypofractionated adaptive strategy appears to be deliverable with soft tissue alignment for the evaluated margins and planning parameters. Research was supported by NIH P01CA116602.« less
Role of step size and max dwell time in anatomy based inverse optimization for prostate implants
Manikandan, Arjunan; Sarkar, Biplab; Rajendran, Vivek Thirupathur; King, Paul R.; Sresty, N.V. Madhusudhana; Holla, Ragavendra; Kotur, Sachin; Nadendla, Sujatha
2013-01-01
In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source. In total, one hundred inverse treatment plans were generated for the four patients included in this study. Twenty-five treatment plans were created for each patient by varying the step size and maximum source dwell time during anatomy-based, inverse-planned optimization. Other relevant treatment planning parameters were kept constant, including the dose constraints and source dwell positions. Each plan was evaluated for target coverage, urethral and rectal dose sparing, treatment time, relative target dose homogeneity, and nonuniformity ratio. The plans with 0.5 cm step size were seen to have clinically acceptable tumor coverage, minimal normal structure doses, and minimum treatment time as compared with the other step sizes. The target coverage for this step size is 87% of the prescription dose, while the urethral and maximum rectal doses were 107.3 and 68.7%, respectively. No appreciable difference in plan quality was observed with variation in maximum source dwell time. The step size plays a significant role in plan optimization for prostate implants. Our study supports use of a 0.5 cm step size for prostate implants. PMID:24049323
Retrieving atmospheric transmissivity for biologically active daily dose, in various european sites
NASA Astrophysics Data System (ADS)
de La Casinière, A.; Touré, M. L.; Lenoble, J.; Cabot, T.
2003-04-01
In the frame of the European Project EDUCE, global UV irradiance spectra recorded all along the year in several European sites are stored in a common database located in Finland. From the spectra set of some of these stations, are calculated atmospheric transmissivities for daily doses of four biologically active UV radiation, namely: UV-B, erythema, DNA damage, and plant damage. A transmissivity is defined as the ratio of the ground level value of the daily dose of interest to its corresponding extra-atmospheric value. Multiple linear correlation of the various transmissivities with three predictors (daily sunshine fraction, cosine of the daily minimum SZA, and daily total ozone column) assumed to be independent variables, are done for year 2000. The coefficients obtained from year 2000 correlation in a given site are expected to retrieve, from the local predictors, the daily dose for year 2001 in the same site, the average error being lesser than 10% for monthly mean values, and lesser than 5% for three-monthly mean values, depending on the daily dose type. Comparison of yearly mean daily doses retrieved in a given site from coefficients obtained in other sites is also presented.
Gallagher, Katherine E; Howard, Natasha; Kabakama, Severin; Mounier-Jack, Sandra; Burchett, Helen E D; LaMontagne, D Scott; Watson-Jones, Deborah
2017-12-01
Since 2007, HPV vaccine has been available to low and middle income countries (LAMIC) for small-scale 'demonstration projects', or national programmes. We analysed coverage achieved in HPV vaccine demonstration projects and national programmes that had completed at least 6 months of implementation between January 2007-2016. A mapping exercise identified 45 LAMICs with HPV vaccine delivery experience. Estimates of coverage and factors influencing coverage were obtained from 56 key informant interviews, a systematic published literature search of 5 databases that identified 61 relevant full texts and 188 solicited unpublished documents, including coverage surveys. Coverage achievements were analysed descriptively against country or project/programme characteristics. Heterogeneity in data, funder requirements, and project/programme design precluded multivariate analysis. Estimates of uptake, schedule completion rates and/or final dose coverage were available from 41 of 45 LAMICs included in the study. Only 17 estimates from 13 countries were from coverage surveys, most were administrative data. Final dose coverage estimates were all over 50% with most between 70% and 90%, and showed no trend over time. The majority of delivery strategies included schools as a vaccination venue. In countries with school enrolment rates below 90%, inclusion of strategies to reach out-of-school girls contributed to obtaining high coverage compared to school-only strategies. There was no correlation between final dose coverage and estimated recurrent financial costs of delivery from cost analyses. Coverage achieved during joint delivery of HPV vaccine combined with another intervention was variable with little/no evaluation of the correlates of success. This is the most comprehensive descriptive analysis of HPV vaccine coverage in LAMICs to date. It is possible to deliver HPV vaccine with excellent coverage in LAMICs. Further good quality data are needed from health facility based delivery strategies and national programmes to aid policymakers to effectively and sustainably scale-up HPV vaccination. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Maintaining high rates of measles immunization in Africa.
Lessler, J; Moss, W J; Lowther, S A; Cummings, D A T
2011-07-01
Supplementary immunization activities (SIAs) are important in achieving high levels of population immunity to measles virus. Using data from a 2006 survey of measles vaccination in Lusaka, Zambia, we developed a model to predict measles immunity following routine vaccination and SIAs, and absent natural infection. Projected population immunity was compared between the current programme and alternatives, including supplementing routine vaccination with a second dose, or SIAs at 1-, 2-, 3-, 4- and 5-year intervals. Current routine vaccination plus frequent SIAs could maintain high levels of population immunity in children aged <5 years, even if each frequent SIA has low coverage (e.g. ≥ 72% for bi-annual 60% coverage SIAs vs. ≥ 69% for quadrennial 95% coverage SIAs). A second dose at 12 months with current coverage could achieve 81% immunity. Circulating measles virus will only increase population immunity. Public health officials should consider frequent SIAs when resources for a two-dose strategy are unavailable.
The impact of reforestation in the northeast United States on precipitation and surface temperature
NASA Astrophysics Data System (ADS)
Clark, Allyson
Since the 1920s, forest coverage in the northeastern United States has recovered from disease, clearing for agricultural and urban development, and the demands of the timber industry. Such a dramatic change in ground cover can influence heat and moisture fluxes to the atmosphere, as measured in altered landscapes in Australia, Israel, and the Amazon. In this study, the impacts of recent reforestation in the northeastern United States on summertime precipitation and surface temperature were quantified by comparing average modern values to 1950s values. Weak positive (negative) relationships between reforestation and average monthly precipitation and daily minimum temperatures (average daily maximum surface temperature) were found. There was no relationship between reforestation and average surface temperature. Results of the observational analysis were compared with results obtained from reforestation scenarios simulated with the BUGS5 global climate model. The single difference between the model runs was the amount of forest coverage in the northeast United States; three levels of forest were defined - a grassland state, with 0% forest coverage, a completely forested state, with approximately 100% forest coverage, and a control state, with forest coverage closely resembling modern forest coverage. The three simulations were compared, and had larger magnitude average changes in precipitation and in all temperature variables. The difference in magnitudes between the model simulations observations was much larger than the difference in the amount of reforestation in each case. Additionally, unlike in observations, a negative relationship was found between average daily minimum temperature and amount of forest coverage, implying that additional factors influence temperature and precipitation in the real world that are not accounted for in the model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, G; Ahunbay, E; Li, X
Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and consideringmore » patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.« less
A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.
Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik
2012-01-01
Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V(10), V(20), and V(30) of 6.3% ± 1.7%, 10.6% ± 3.9%, and 12.9% ± 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% ± 2.5%, 7.2% ± 2.5%, and 10.6% ± 3.6%, respectively. The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.
2007-02-01
bladder and the rectum are overprotected while the PTV coverage is undesirably reduced. On the other hand, if their maximum dose is increased and/or...B, the bladder and rectum were overprotected with undesirably low PTV coverage (84.54%). The reduction of their weighting factor increased PTV
Shiue, Harn J; Taylor, Maria; Sands, Kara A
2017-10-01
Levetiracetam (LEV) is primarily renally eliminated. In end-stage renal disease (ESRD) patients on hemodialysis (HD), pharmacokinetic studies recommend daily dosing with 50% supplemental doses after 4-hour HD sessions. However, poor medication adherence after HD could result in fluctuating plasma drug levels. To compare two LEV dosing regimens, daily versus twice-daily (BID), in ESRD patients undergoing HD. Consecutive ESRD patients (April 2013 to May 2014) receiving maintenance inpatient HD and prescribed LEV prior to admission to our academic tertiary hospital were prospectively analyzed. Demographics, initial lab values, adverse reactions, seizures, and LEV regimens were recorded. LEV levels were obtained pre-HD and post-HD along with levels after receiving post-HD doses. Recovery of plasma levels after HD was assessed by comparison of levels predialysis versus postdialysis and post-HD doses. We identified 22 patients who met inclusion criteria; 14 BID and 8 daily dosing. Mean predialysis, postdialysis, and post-HD dose plasma levels were higher in patients receiving LEV BID compared with daily (43.1 ± 6.3, 19.4 ± 5.2, 34.9 ± 4.3 vs 21.1 ± 3.9, 6.9 ± 1.5, 11.9 ± 1.7 µg/mL; P < 0.05). BID post-HD levels were 41.9 ± 4.6% of predialysis levels versus 36.9 ± 7.3% with daily dosing ( P = 0.275). Post-HD dose levels were 81.4±4.3% of predialysis on LEV BID versus 65.7 ± 8.8% on LEV daily ( P = 0.045). No seizures were reported during hospital admission in either group. Compared to LEV daily, BID dosing achieved significantly higher levels and a better recovery to predialysis levels. Although limited by small numbers, a similar relationship between postdialysis levels was not detected.
Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A
2018-06-01
Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Pathela, Preeti; Jamison, Kelly; Papadouka, Vikki; Kabir, Rezaul; Markowitz, Lauri E; Dunne, Eileen F; Schillinger, Julia A
2016-12-01
Human papillomavirus (HPV) vaccine is recommended for adolescents. By the end of 2013, 64% of female and 40% of male New York City residents aged 13-18 years had received ≥1 HPV vaccine dose. Adolescents attending sexually transmitted disease (STD) clinics are at high risk for HPV exposure and could benefit from vaccination. Our objective was to estimate HPV vaccination coverage for this population. We matched records of New York City's STD clinic patients aged 13-18 years during 2010-2013 with the Citywide Immunization Registry. We assessed HPV vaccine initiation (≥1 dose) and series completion (≥3 doses among those who initiated) as of clinic visit date and by patient demographics. We compared receipt of ≥1 dose for HPV, tetanus-diphtheria-acellular pertussis, and meningococcal conjugate vaccine. Eighty-two percent of clinic attendees (13,505/16,364) had records in the Citywide Immunization Registry. Receipt of ≥1 HPV dose increased during 2010-2013 (females: 57.6%-69.7%; males: 1.5%-36.3%). Among females, ≥1-dose coverage was lowest among whites (53.4%) and highest among Hispanics (73.3%); among males, ≥1-dose coverage was lowest among whites (6.9%) and highest among Asians (20.9%). Series completion averaged 57.7% (females) and 28.0% (males), with little variation by race/ethnicity or poverty level. Receipt of ≥1 dose was 59.7% for HPV, 82% for tetanus-diphtheria-acellular pertussis, and 76% for meningococcal conjugate vaccines. HPV vaccine initiation and completion were low among adolescent STD clinic patients; coverage was lower compared with other recommended vaccines. STD clinics may be good venues for delivering HPV vaccine, thereby enhancing efforts to improve HPV vaccination. Copyright © 2016 Society for Adolescent Health and Medicine. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists ofmore » multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, Andrew, E-mail: aojones@geisinger.edu; Treas, Jared; Yavoich, Brian
2014-01-01
The aim of the study was to investigate the differences between intraoperative and postoperative dosimetry for transrectal ultrasound–guided transperineal prostate implants using cesium-131 ({sup 131}Cs). Between 2006 and 2010, 166 patients implanted with {sup 131}Cs had both intraoperative and postoperative dosimetry studies. All cases were monotherapy and doses of 115 were prescribed to the prostate. The dosimetric properties (D{sub 90}, V{sub 150}, and V{sub 100} for the prostate) of the studies were compared. Two conformity indices were also calculated and compared. Finally, the prostate was automatically sectioned into 6 sectors (anterior and posterior sectors at the base, midgland, and apex)more » and the intraoperative and postoperative dosimetry was compared in each individual sector. Postoperative dosimetry showed statistically significant changes (p < 0.01) in every dosimetric value except V{sub 150}. In each significant case, the postoperative plans showed lower dose coverage. The conformity indexes also showed a bimodal frequency distribution with the index indicating poorer dose conformity in the postoperative plans. Sector analysis revealed less dose coverage postoperatively in the base and apex sectors with an increase in dose to the posterior midgland sector. Postoperative dosimetry overall and in specific sectors of the prostate differs significantly from intraoperative planning. Care must be taken during the intraoperative planning stage to ensure complete dose coverage of the prostate with the understanding that the final postoperative dosimetry will show less dose coverage.« less
Lu, Peng-Jun; O'Halloran, Alissa C; Williams, Walter W; Nelson, Noele P
2018-04-28
Persons from the United States who travel to developing countries are at substantial risk for hepatitis B virus (HBV) infection. Hepatitis B vaccine has been recommended for adults at increased risk for infection, including travelers to high or intermediate hepatitis B endemic countries. To assess hepatitis B vaccination coverage among adults ≥18 years traveling to a country of high or intermediate endemicity from the United States. Data from the 2015 National Health Interview Survey (NHIS) were analyzed to determine hepatitis B vaccination coverage (≥1 dose) and series completion (≥3 doses) among persons aged ≥18 years who reported traveling to a country of high or intermediate hepatitis B endemicity. Multivariable logistic regression and predictive marginal analyses were conducted to identify factors independently associated with hepatitis B vaccination. In 2015, hepatitis B vaccination coverage (≥1 dose) among adults aged ≥18 years who reported traveling to high or intermediate hepatitis B endemic countries was 38.6%, significantly higher compared with 25.9% among non-travelers. Series completion (≥3 doses) was 31.7% and 21.2%, respectively (P < 0.05). On multivariable analysis among all respondents, travel status was significantly associated with hepatitis B vaccination coverage and series completion. Other characteristics independently associated with vaccination (≥1 dose, and ≥3 doses) among travelers included age, race/ethnicity, educational level, duration of US residence, number of physician contacts in the past year, status of ever being tested for HIV, and healthcare personnel status. Although travel to a country of high or intermediate hepatitis B endemicity was associated with higher likelihood of hepatitis B vaccination, hepatitis B vaccination coverage was low among adult travelers to these areas. Healthcare providers should ask their patients about travel plans and recommend and offer travel related vaccinations to their patients or refer them to alternate sites for vaccination. Published by Elsevier Ltd.
Lu, Peng-Jun; O'Halloran, Alissa C; Williams, Walter W; Nelson, Noele P
2018-04-25
Persons from the United States who travel to developing countries are at substantial risk for hepatitis B virus (HBV) infection. Hepatitis B vaccine has been recommended for adults at increased risk for infection, including travelers to high or intermediate hepatitis B endemic countries. To assess hepatitis B vaccination coverage among adults ≥ 18 years traveling to a country of high or intermediate endemicity from the United States. Data from the 2015 National Health Interview Survey (NHIS) were analyzed to determine hepatitis B vaccination coverage (≥1 dose) and series completion (≥3 doses) among persons aged ≥ 18 years who reported traveling to a country of high or intermediate hepatitis B endemicity. Multivariable logistic regression and predictive marginal analyses were conducted to identify factors independently associated with hepatitis B vaccination. In 2015, hepatitis B vaccination coverage (≥1 dose) among adults aged ≥ 18 years who reported traveling to high or intermediate hepatitis B endemic countries was 38.6%, significantly higher compared with 25.9% among non-travelers. Series completion (≥3 doses) was 31.7% and 21.2%, respectively (P < 0.05). On multivariable analysis among all respondents, travel status was significantly associated with hepatitis B vaccination coverage and series completion. Other characteristics independently associated with vaccination (≥1 dose, and ≥ 3 doses) among travelers included age, race/ethnicity, educational level, duration of U.S. residence, number of physician contacts in the past year, status of ever being tested for HIV, and healthcare personnel status. Although travel to a country of high or intermediate hepatitis B endemicity was associated with higher likelihood of hepatitis B vaccination, hepatitis B vaccination coverage was low among adult travelers to these areas. Healthcare providers should ask their patients about travel plans and recommend and offer travel related vaccinations to their patients or refer them to alternate sites for vaccination. Published by Elsevier Ltd.
Yun, Ji Young; Kim, Han-Joon; Lee, Jee-Young; Kim, Young Eun; Kim, Ji Seon; Kim, Jong-Min; Jeon, Beom S
2013-09-02
Ropinirole prolonged release (RPR) is a once-daily formulation. However, there may be individual pharmacokinetic differences so that multiple dosing may be preferred in some individuals. This study compares once-daily and twice-daily RPR in patients with Parkinson's disease. This study was an open-label crossover study. We enrolled Parkinson's disease patients on dopamine agonist therapy with unsatisfactory control such as motor fluctuation, dyskinesia and sleep-related problems. Agonists were switched into equivalent dose of RPR. Subjects were consecutively enrolled into either once-daily first or twice-daily first groups, and received the same amount of RPR in a single and two divided dosing for 8 weeks respectively in a crossover manner without a washout period.The primary outcome was a questionnaire of the preference completed by patients in the last visit. The secondary outcome measures included the Unified Parkinson's Disease Rating Scale part 3 (mUPDRS), Hoehn and Yahr stage (H&Y); sleep questionnaire including overall quality of sleep, nocturnal off symptoms and early morning symptoms; Epworth Sleep Scale (ESS); compliances and patient global impression (PGI). A total of 82 patients were enrolled and 61 completed the study. 31 patients preferred twice-daily regimen, 17 preferred the once-daily regimen, and 13 had no preference. Their mean mUPDRS, H&Y, ESS, sleep quality, compliance and adverse events were not statistically different in both regimens. PGI-improvement on wearing off defined was better in twice-daily dosing regimen. RPR is a once-daily formulation, but multiple dosing was preferred in many patients. Multiple dosing of RPR might be a therapeutic option if once-daily dosing is unsatisfactory.
Cavalca, V; Rocca, B; Veglia, F; Petrucci, G; Porro, B; Myasoedova, V; De Cristofaro, R; Turnu, L; Bonomi, A; Songia, P; Cavallotti, L; Zanobini, M; Camera, M; Alamanni, F; Parolari, A; Patrono, C; Tremoli, E
2017-11-01
On-pump cardiac surgery may trigger inflammation and accelerate platelet cyclooxygenase-1 renewal, thereby modifying low-dose aspirin pharmacodynamics. Thirty-seven patients on standard aspirin 100 mg once-daily were studied before surgery and randomized within 36 hours postsurgery to 100 mg once-daily, 100 mg twice-daily, or 200 mg once-daily for 90 days. On day 7 postsurgery, immature and mature platelets, platelet mass, thrombopoietin, glycocalicin, leukocytes, C-reactive protein, and interleukin-6 significantly increased. Interleukin-6 significantly correlated with immature platelets. At day 7, patients randomized to 100 mg once-daily showed a significant increase in serum thromboxane (TX)B 2 within the 24-hour dosing interval and urinary TXA 2 metabolite (TXM) excretion. Aspirin 100 mg twice-daily lowered serum TXB 2 and prevented postsurgery TXM increase (P < 0.01), without affecting prostacyclin metabolite excretion. After cardiac surgery, shortening the dosing interval, but not doubling the once-daily dose, rescues the impaired antiplatelet effect of low-dose aspirin and prevents platelet activation associated with acute inflammation and enhanced platelet turnover. © 2017 American Society for Clinical Pharmacology and Therapeutics.
Guffon, Nathalie; Bröijersén, Anders; Palmgren, Ingrid; Rudebeck, Mattias; Olsson, Birgitta
2018-01-01
Although nitisinone is successfully used to treat hereditary tyrosinemia type 1 (HT-1) with the recommended twice-daily dosing, data describing a long half-life motivate less frequent dosing. Therefore, in agreement with the Pharmacovigilance Risk Assessment Committee at the European Medicines Agency, this study was performed to investigate the switch to once-daily dosing. This open-label, non-randomized, single-sequence crossover study evaluated the pharmacokinetics, efficacy, and safety of once-daily compared to twice-daily dosing of nitisinone in patients with HT-1 (NCT02323529). Well-controlled patients of <2, 2 to <12, 12 to <18, and ≥18 years of age who were on twice-daily dosing were eligible for participation. Nitisinone and succinylacetone levels were determined from dry blood spots by tandem mass spectrometry. The primary endpoint was C min of nitisinone after ≥4 weeks of treatment on each dosing regimen. Secondary objectives were evaluation of efficacy and safety during each dosing regimen. In total, 19 patients were enrolled and 17 included in the per-protocol analysis set. The mean (SD) nitisinone C min decreased by 23%, from 26.4 (10.2) to 21.2 (9.9) μmol/L in dry blood spot samples (not equivalent to plasma concentrations), when patients switched from twice- to once-daily dosing. There was no apparent age- or bodyweight-related trend in the degree of C min decrease. No patient had quantifiable succinylacetone levels during the once-daily treatment period, indicating efficacious treatment. All adverse events were mild or moderate and judged unrelated to nitisinone. The switch to once-daily treatment with nitisinone appeared efficacious and safe in the treatment of patients with HT-1.
Tyler, Madelaine K
2016-01-08
This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.
Fogliata, Antonella; Scorsetti, Marta; Navarria, Piera; Catalano, Maddalena; Clivio, Alessandro; Cozzi, Luca; Lobefalo, Francesca; Nicolini, Giorgia; Palumbo, Valentina; Pellegrini, Chiara; Reggiori, Giacomo; Roggio, Antonella; Vanetti, Eugenio; Alongi, Filippo; Pentimalli, Sara; Mancosu, Pietro
2013-04-01
To appraise the potential of volumetric modulated arc therapy (VMAT, RapidArc) and proton beams to simultaneously achieve target coverage and enhanced sparing of bone tissue in the treatment of soft-tissue sarcoma with adequate target coverage. Ten patients presenting with soft-tissue sarcoma of the leg were collected for the study. Dose was prescribed to 66.5 Gy in 25 fractions to the planning target volume (PTV) while significant maximum dose to the bone was constrained to 50 Gy. Plans were optimised according to the RapidArc technique with 6 MV photon beams or for intensity modulated protons. RapidArc photon plans were computed with: 1) AAA; 2) Acuros XB as dose to medium; and 3) Acuros XB as dose to water. All plans acceptably met the criteria of target coverage (V95% >90-95%) and bone sparing (D(1 cm3) <50 Gy). Significantly higher PTV dose homogeneity was found for proton plans. Near-to-maximum dose to bone was similar for RapidArc and protons, while volume receiving medium/low dose levels was minimised with protons. Similar results were obtained for the remaining normal tissue. Dose distributions calculated with the dose to water option resulted ~5% higher than corresponding ones computed as dose to medium. High plan quality was demonstrated for both VMAT and proton techniques when applied to soft-tissue sarcoma.
Lim, K K; Chan, Y Y; Noor Ani, A; Rohani, J; Siti Norfadhilah, Z A; Santhi, M R
2017-12-01
The success of the Expanded Program on Immunization among children will greatly reduce the burden of illness and disability from vaccine preventable diseases. The aim of the study was to evaluate the complete immunization coverage and its determinants among children aged 12-23 months in Malaysia. Cross-sectional study. Data on immunization were extracted from the 2016 National Health and Morbidity Survey. Complete immunization coverage was classified as received all recommended primary vaccine doses by the age of 12 months and verified by vaccination cards, and incompletely immunized if they received partially recommended vaccine dose or not received any recommended vaccine dose or had no vaccination card. The multiple logistic regression analyses were conducted to determine the sociodemographic factors associated with complete immunization coverage. The overall complete immunization coverage among children (verified by cards) was 86.4% (n = 8920, 95% confidence interval: 85.4-87.4). Multivariable logistic regression analyses model revealed that factors significantly associated with complete immunization coverage were ethnicity, occupation of the mother, head of household's education level, and head of household's occupation. While sex, citizenship, household income, mother's age, and marital status were not significantly associated with complete immunization coverage. According to the World Health Organization criteria, the present study demonstrated that the immunization coverage of 86.4% is still unsatisfactory. Thus, the current intervention program should be enhanced in order to achieve the 95% coverage for all antigens in the national vaccination program. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Homophobia as a barrier to comprehensive media coverage of the Ugandan anti-homosexual bill.
Strand, Cecilia
2012-01-01
The Ugandan Anti-Homosexuality Bill of October 2009 caused an international outcry and sparked intense debate in the local media. This article explores to what degree a discriminatory social environment manifests itself in the Ugandan print media and discusses the potential implications for media's coverage of contentious policy options such as the Anti-Homosexuality Bill. A content analysis of 115 items from two daily newspapers (the government-owned New Vision and the privately owned the Daily Monitor, between October and December 2009) indicates the existence of two separate house styles; this is in spite of the fact that both newspapers reproduce the surrounding society's homophobia, albeit with different frequency. Unlike the New Vision, the Daily Monitor includes coverage on homophobia and discrimination, as well as provides space for criticism of the Bill. By acknowledging discrimination and its negative impact, the newspaper de-legitimizes homophobia and problematizes the proposed Anti-homosexuality Bill for their readers.
Matsuki, Takanobu; Okano, Yoshiko; Aoki, Yoshinori; Ishida, Yutaka; Hatano, Kentaro; Kumano, Kimiko
2014-12-01
Thalidomide is a TNF-alpha inhibitor and has been administrated for erythema nodosum leprosum (ENL, Type II leprosy reaction) which is one of leprosy reactions and can cause serious illness to patients oflepromatous pole among the immune spectrum. Twenty live cases (at May, 2011) were identified to whom thalidomide had been administrated since 1978 for their ENL reactions. Data were collected from their clinical records in order to evaluate the usage and effectiveness of thalidomide in National Sanatorium Oku-Komyoen, Okayama, Setouchi-city, Japan. Individual data includes bacillary index (BI), total dose, average daily dose, maximum daily dose, minimum daily dose, methods of thalidomide administration and change of symptoms of ENL. Results: No adverse effect was found among 20 cases. Average daily dose of 20 cases was 19 mg. Regarding to the maximum daily dose, in 3 cases (15%) more than 100 mg, in 3 cases (15%) 50 mg, and in 14 cases (70%) less than 40 mg was administrated. Dose was gradually tapered in most cases. From clinical records, thalidomide was found effective for ENL in 19 cases and clinicians concerned were trying to adjust the proper dose of the drug carefully depending on the current symptoms, because there was no guideline of thalidomide administration for ENL. This data suggests that even less than 50-100 mg as the initial daily dose was still effective, though 50-100 mg daily dose is recommended in the current guideline of Japan (2011) and more dose had been administrated in USA and India.
Risk in daily newspaper coverage of red tide blooms in Southwest Florida.
Li, Zongchao; Garrison, Bruce; Ullmann, Steven G; Kirkpatrick, Barbara; Fleming, Lora E; Hoagland, Porter
This study investigated newspaper coverage of Florida red tide blooms in four metropolitan areas of Southwest Florida during a 25-year period, 1987-2012. We focused on how journalists framed red tide stories with respect to environmental risk, health risk, and economic risk. We determined risk to be a key factor in this news coverage, being an aspect of coverage of red tide itself in terms of environmental risk, tourism risk, and public health risk. The study found that red tide news coverage is most often framed as an environmental story.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laoui, S; Dietrich, S; Sehgal, V
2016-06-15
Purpose: Radiation dose delivery for endometrial cancer using HDR techniques is limited by dose to bladder and rectum. A dosimetric study was performed using Varian Capri vaginal brachytherapy applicator to determine the optimal channel configuration which minimizes dose to bladder and rectum, while providing good target coverage. Methods: A total of 17 patients, 63 plans clinically delivered, and 252 simulated plans using Varian BrachyVision planning system were generated to investigate optimal channel configuration which results in minimum dose to bladder and rectum while providing adequate target coverage. The Capri applicator consists of 13 lumens arranged in two concentric rings, onemore » central lumen and six lumens per ring. Manual dose shaping is invariably required to lower the dose to critical organs. Three-dimensional plans were simulated for 4 channel arrangements, all 13 channels, channel 12 o’clock (close to bladder) and 6 o’clock (close to rectum) deactivated, central channel deactivated, and central channel in addition to 12 o’clock and 6 o’clock deactivated. A relationship between V100, the volume that receives the prescribed dose, and the amount of curie-seconds required to deliver it, was established. Results: Using all 13 channels results in maximum dose to bladder and rectum. Deactivating central channel in addition to 12 o’clock and 6 o’clock resulted in minimizing bladder and rectum doses but compromised target coverage. The relationship between V100, the volume that receives the prescribed dose, and the curie seconds was found to be linear. Conclusion: Deactivating channels 12 o’clock and 6 o’clock was shown to be the optimal configuration leading to minimum dose to bladder and rectum without compromising target coverage. The linear relationship between V100 and the curie- seconds can be used as a verification parameter.« less
Twice-Daily versus Once-Daily Pramipexole Extended Release Dosage Regimens in Parkinson's Disease.
Yun, Ji Young; Kim, Young Eun; Yang, Hui-Jun; Kim, Han-Joon; Jeon, Beomseok
2017-01-01
This open-label study aimed to compare once-daily and twice-daily pramipexole extended release (PER) treatment in Parkinson's disease (PD). PD patients on dopamine agonist therapy, but with unsatisfactory control, were enrolled. Existing agonist doses were switched into equivalent PER doses. Subjects were consecutively enrolled into either once-daily-first or twice-daily-first groups and received the prescribed amount in one or two, respectively, daily doses for 8 weeks. For the second period, subjects switched regimens in a crossover manner. The forty-four patients completed a questionnaire requesting preference during their last visit. We measured the UPDRS-III, Hoehn and Yahr stages (H&Y) in medication-on state, Parkinson's disease sleep scale (PDSS), and Epworth Sleepiness Scale. Eighteen patients preferred a twice-daily regimen, 12 preferred a once-daily regimen, and 14 had no preference. After the trial, 14 subjects wanted to be on a once-daily regimen, 25 chose a twice-daily regimen, and 5 wanted to maintain the prestudy regimen. Main reasons for choosing the twice-daily regimen were decreased off-duration, more tolerable off-symptoms, and psychological stability. The mean UPDRS-III, H&Y, and PDSS were not different. Daytime sleepiness was significantly high in the once-daily regimen, whereas nocturnal hallucinations were more common in the twice-daily. Multiple dosing should be considered if once-daily dosing is unsatisfactory. This study is registered as NCT01515774 at ClinicalTrials.gov.
Risk in Daily Newspaper Coverage of Red Tide Blooms in Southwest Florida
ERIC Educational Resources Information Center
Li, Zongchao; Garrison, Bruce; Ullmann, Steven G.; Kirkpatrick, Barbara; Fleming, Lora E.; Hoagland, Porter
2015-01-01
This study investigated newspaper coverage of Florida red tide blooms in four metropolitan areas of Southwest Florida during a 25-year period, 1987-2012. We focused on how journalists framed red tide stories with respect to environmental risk, health risk, and economic risk. We determined risk to be a key factor in this news coverage, being an…
Complementary satellite sound broadcasting systems: A NASA assessment for the Voice of America
NASA Technical Reports Server (NTRS)
Stevens, Grady H.; Spence, Rodney L.
1988-01-01
Satellite concepts are examined which offer potentially significant sound broadcast coverage of audio as a complement to VOA's existing and planned terrestrial sound broadcasting system. HF bands are emphasized but additional discussion is included for systems using higher frequencies. Low altitude satellites, shuttle altitude (275 km) and sun synchronous (about 1600 to 1800 km), would not be practical for international broadcasting since many satellites would be required for reliable and widespread coverage. Two concepts are discussed which would offer significant and practical broadcast coverage at HF. One, an 8-hr posigrade equatorial orbit, would offer about 1 hr of widespread, twice daily, coverage to three areas of the globe. The time of coverage is even greater when confined to densely populated areas only (2 to 3 hrs). Another orbit, the Apogee at Constant Time/Equatorial (ACE), provides the same coverage, but only once daily to each area. The latter orbit is highly elliptical, allowing insertion of a greater payload (more broadcast channels) with the existing launch capability. The ACE and 8-hr orbit concepts led to systems of about equal costs, with the ACE being slightly better.
NASA Astrophysics Data System (ADS)
Krzyścin, Janusz W.; Sobolewski, Piotr S.
2018-01-01
Erythemal daily doses measured at the Polish Polar Station, Hornsund (77°00' N, 15°33' E), for the periods 1996-2001 and 2005-2016 are homogenized using yearly calibration constants derived from the comparison of observed doses for cloudless conditions with the corresponding doses calculated by radiative transfer (RT) simulations. Modeled all-sky doses are calculated by the multiplication of cloudless RT doses by the empirical cloud modification factor dependent on the daily sunshine duration. An all-sky model is built using daily erythemal doses measured in the period 2005-2006-2007. The model is verified by comparisons with the 1996-1997-1998 and 2009-2010-2011 measured data. The daily doses since 1983 (beginning of the proxy data) are reconstructed using the all-sky model with the historical data of the column ozone from satellite measurements (SBUV merged ozone data set), the snow depth (for ground albedo estimation), and the observed daily sunshine duration at the site. Trend analyses of the monthly and yearly time series comprised of the reconstructed and observed doses do not reveal a statistically significant trend in the period 1983-2016. The trends based on the observed data only (1996-2001 and 2005-2016) show declining tendency (about -1 % per year) in the monthly mean of daily erythemal doses in May and June, and in the yearly sum of daily erythemal doses. An analysis of sources of the yearly dose variability since 1983 shows that cloud cover changes are a basic driver of the long-term UV changes at the site.
Systematic review of the incremental costs of interventions that increase immunization coverage.
Ozawa, Sachiko; Yemeke, Tatenda T; Thompson, Kimberly M
2018-05-10
Achieving and maintaining high vaccination coverage requires investments, but the costs and effectiveness of interventions to increase coverage remain poorly characterized. We conducted a systematic review of the literature to identify peer-reviewed studies published in English that reported interventions aimed at increasing immunization coverage and the associated costs and effectiveness of the interventions. We found limited information in the literature, with many studies reporting effectiveness estimates, but not providing cost information. Using the available data, we developed a cost function to support future programmatic decisions about investments in interventions to increase immunization coverage for relatively low and high-income countries. The cost function estimates the non-vaccine cost per dose of interventions to increase absolute immunization coverage by one percent, through either campaigns or routine immunization. The cost per dose per percent increase in absolute coverage increased with higher baseline coverage, demonstrating increasing incremental costs required to reach higher coverage levels. Future studies should evaluate the performance of the cost function and add to the database of available evidence to better characterize heterogeneity in costs and generalizability of the cost function. Copyright © 2018. Published by Elsevier Ltd.
Riha, Gordon M; Van, Philbert Y; Differding, Jerome A; Schreiber, Martin A
2012-05-01
The purpose of this study was to analyze whether 2 standard dosing regimens of enoxaparin (30 mg twice daily vs 40 mg once daily) would result in different deep vein thrombosis (DVT) rates and anti-factor Xa activity (anti-Xa) in surgical patients. Patients who required enoxaparin for prophylaxis were followed prospectively. Demographics were recorded. Patients underwent standardized duplex screening. Peak anti-Xa levels were drawn on 4 consecutive days. Sixty-three patients were followed up (28 patients on 30 mg twice daily, 35 patients on 40 mg once daily). There was no significant difference in demographics between groups. Twenty-five percent of patients on 30 mg twice daily developed a DVT, whereas 2.9% of patients on 40 mg once daily developed a DVT. Patients on 30 mg twice daily had significantly lower anti-Xa levels. The incidence of DVT is increased in surgical patients who receive 30 mg twice daily dosing of enoxaparin compared with 40 mg daily. Dosing of 40 mg once daily results in significantly higher peak anti-Xa levels compared with 30 mg twice daily. Copyright © 2012 Elsevier Inc. All rights reserved.
Determinants of apparent rural-urban differentials in measles vaccination uptake in Indonesia.
Fernandez, Renae C; Awofeso, Niyi; Rammohan, Anu
2011-01-01
Regional differences in vaccination uptake are common in both developed and developing countries, and are often linked to the availability of healthcare services and socioeconomic factors. In 2007, 0.9 million eligible Indonesian children missed measles vaccination, and 19 456 cases of measles were documented among Indonesian children. The authors investigated rural-urban differentials in measles vaccination coverage among young Indonesian children, and sought to identify key factors influencing the probability of a child receiving the first dose of measles vaccination in Indonesia. Data used in the analyses were sourced from the nationally representative Indonesia Demographic and Health Survey 2007. The influence of location of residence, household wealth, maternal and paternal education, total children ever born and use of skilled birth attendants on measles vaccination coverage was investigated using bivariate analysis and chi-square tests. The independent effects of these variables were established using binomial logistic regression analysis. Indonesia's 2007 first-dose measles national vaccination coverage was, at 72.8%, lower than the 2008 global first-dose measles vaccination average coverage of 82%. Bivariate analysis revealed that the first-dose measles vaccination coverage in rural areas of Indonesia was 68.5%, compared with 80.1% in urban regions (p < 0.001). The apparent significance of rural residence in impairing vaccination coverage was marginal after controlling for the sex of the child, maternal age, maternal and paternal education, wealth, and access to skilled health workers. Apart from sustainable initiatives to increase measles vaccination coverage globally, it is important to close the rural-urban gap in Indonesia's measles vaccination uptake. Addressing critical determinants of inferior measles vaccination coverage in Indonesia's rural regions will facilitate major improvements in Indonesia's child health trends. This article suggests initiatives for addressing three of such determinants in Indonesia's rural areas: poverty, parental education and access to skilled health workers.
Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yadav, Poonam, E-mail: yadav@humonc.wisc.edu; Department of Medical Physics, University of Wisconsin, Madison, WI; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI
2013-10-01
Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison ofmore » target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.« less
Gauer, Tobias; Sothmann, Thilo; Blanck, Oliver; Petersen, Cordula; Werner, René
2018-06-01
Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.
Comparing Treatment Plan in All Locations of Esophageal Cancer
Lin, Jang-Chun; Tsai, Jo-Ting; Chang, Chih-Chieh; Jen, Yee-Min; Li, Ming-Hsien; Liu, Wei-Hsiu
2015-01-01
Abstract The aim of this study was to compare treatment plans of volumetric modulated arc therapy (VMAT) with intensity-modulated radiotherapy (IMRT) for all esophageal cancer (EC) tumor locations. This retrospective study from July 2009 to June 2014 included 20 patients with EC who received definitive concurrent chemoradiotherapy with radiation doses >50.4 Gy. Version 9.2 of Pinnacle3 with SmartArc was used for treatment planning. Dosimetric quality was evaluated based on doses to several organs at risk, including the spinal cord, heart, and lung, over the same coverage of gross tumor volume. In upper thoracic EC, the IMRT treatment plan had a lower lung mean dose (P = 0.0126) and lung V5 (P = 0.0037) compared with VMAT; both techniques had similar coverage of the planning target volumes (PTVs) (P = 0.3575). In middle thoracic EC, a lower lung mean dose (P = 0.0010) and V5 (P = 0.0145), but higher lung V20 (P = 0.0034), spinal cord Dmax (P = 0.0262), and heart mean dose (P = 0.0054), were observed for IMRT compared with VMAT; IMRT provided better PTV coverage. Patients with lower thoracic ECs had a lower lung mean dose (P = 0.0469) and V5 (P = 0.0039), but higher spinal cord Dmax (P = 0.0301) and heart mean dose (P = 0.0020), with IMRT compared with VMAT. PTV coverage was similar (P = 0.0858) for the 2 techniques. IMRT provided a lower mean dose and lung V5 in upper thoracic EC compared with VMAT, but exhibited different advantages and disadvantages in patients with middle or lower thoracic ECs. Thus, choosing different techniques for different EC locations is warranted. PMID:25929910
Lin, Jang-Chun; Tsai, Jo-Ting; Chang, Chih-Chieh; Jen, Yee-Min; Li, Ming-Hsien; Liu, Wei-Hsiu
2015-05-01
The aim of this study was to compare treatment plans of volumetric modulated arc therapy (VMAT) with intensity-modulated radiotherapy (IMRT) for all esophageal cancer (EC) tumor locations.This retrospective study from July 2009 to June 2014 included 20 patients with EC who received definitive concurrent chemoradiotherapy with radiation doses >50.4 Gy. Version 9.2 of Pinnacle with SmartArc was used for treatment planning. Dosimetric quality was evaluated based on doses to several organs at risk, including the spinal cord, heart, and lung, over the same coverage of gross tumor volume.In upper thoracic EC, the IMRT treatment plan had a lower lung mean dose (P = 0.0126) and lung V5 (P = 0.0037) compared with VMAT; both techniques had similar coverage of the planning target volumes (PTVs) (P = 0.3575). In middle thoracic EC, a lower lung mean dose (P = 0.0010) and V5 (P = 0.0145), but higher lung V20 (P = 0.0034), spinal cord Dmax (P = 0.0262), and heart mean dose (P = 0.0054), were observed for IMRT compared with VMAT; IMRT provided better PTV coverage. Patients with lower thoracic ECs had a lower lung mean dose (P = 0.0469) and V5 (P = 0.0039), but higher spinal cord Dmax (P = 0.0301) and heart mean dose (P = 0.0020), with IMRT compared with VMAT. PTV coverage was similar (P = 0.0858) for the 2 techniques.IMRT provided a lower mean dose and lung V5 in upper thoracic EC compared with VMAT, but exhibited different advantages and disadvantages in patients with middle or lower thoracic ECs. Thus, choosing different techniques for different EC locations is warranted.
Nkiwane, Karen S; Pötter, Richard; Tanderup, Kari; Federico, Mario; Lindegaard, Jacob C; Kirisits, Christian
2013-01-01
Three-dimensional evaluation and comparison of target and organs at risk (OARs) doses from two traditional standard source loading patterns in the frame of MRI-guided cervical cancer brachytherapy for various clinical scenarios based on patient data collected in a multicenter trial setting. Two nonoptimized three-dimensional MRI-based treatment plans, Plan 1 (tandem and vaginal loading) and Plan 2 (tandem loading only), were generated for 134 patients from seven centers participating in the EMBRACE study. Both plans were normalized to point A (Pt. A). Target and OAR doses were evaluated in terms of minimum dose to 90% of the high-risk clinical target volume (HRCTV D90) grouped by tumor stage and minimum dose to the most exposed 2cm³ of the OARs volume. An HRCTV D90 ≥ Pt. A was achieved in 82% and 44% of the patients with Plans 1 and 2, respectively. Median HRCTV D90 with Plans 1 and 2 was 120% and 90% of Pt. A dose, respectively. Both plans had optimal dose coverage in 88% of Stage IB tumors; however, the tandem-only plan resulted in about 50% of dose reduction to the vagina and rectum. For Stages IIB and IIIB, Plan 1 had on average 35% better target coverage but with significant doses to OARs. Standard tandem loading alone results in good target coverage in most Stage IB tumors without violating OAR dose constraints. For Stage IIB tumors, standard vaginal loading improves the therapeutic window, however needs optimization to fulfill the dose prescription for target and OAR. In Stage IIIB, even optimized vaginal loading often does not fulfill the needs for dose prescription. The significant dose variation across various clinical scenarios for both target and OARs indicates the need for image-guided brachytherapy for optimal dose adaptation both for limited and advanced diseases. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Oral Cholera Vaccine Coverage during an Outbreak and Humanitarian Crisis, Iraq, 2015.
Lam, Eugene; Al-Tamimi, Wasan; Russell, Steven Paul; Butt, Muhammad Obaid-Ul Islam; Blanton, Curtis; Musani, Altaf Sadrudin; Date, Kashmira
2017-01-01
During November-December 2015, as part of the 2015 cholera outbreak response in Iraq, the Iraqi Ministry of Health targeted ≈255,000 displaced persons >1 year of age with 2 doses of oral cholera vaccine (OCV). All persons who received vaccines were living in selected refugee camps, internally displaced persons camps, and collective centers. We conducted a multistage cluster survey to obtain OCV coverage estimates in 10 governorates that were targeted during the campaign. In total, 1,226 household and 5,007 individual interviews were conducted. Overall, 2-dose OCV coverage in the targeted camps was 87% (95% CI 85%-89%). Two-dose OCV coverage in the 3 northern governorates (91%; 95% CI 87%-94%) was higher than that in the 7 southern and central governorates (80%; 95% CI 77%-82%). The experience in Iraq demonstrates that OCV campaigns can be successfully implemented as part of a comprehensive response to cholera outbreaks among high-risk populations in conflict settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, T; Dooley, J; Zhu, T
2016-06-15
Purpose: Clinical implementations of adaptive radiotherapy (ART) are limited mainly by the requirement of delivery QA (DQA) prior to the treatment. Small segment size and small segment MU are two dominant factors causing failures of DQA. The aim of this project is to explore the feasibility of ART treatment without DQA by using a partial optimization approach. Methods: A retrospective simulation study was performed on two prostate cancer patients treated with SMLC-IMRT. The prescription was 180cGx25 fractions with daily CT-on-rail imaging for target alignment. For each patient, seven daily CTs were selected randomly across treatment course. The contours were deformablelymore » transferred from the simulation CT onto the daily CTs and modified appropriately. For each selected treatment, dose distributions from original beams were calculated on the daily treatment CTs (DCT plan). An ART plan was also created by optimizing the segmental MU only, while the segment shapes were preserved and the minimum MU constraint was respected. The overlaps, between PTV and the rectum, between PTV and the bladder, were normalized by the PTV volume. This ratio was used to characterize the difficulty of organs-at-risk (OAR) sparing. Results: Comparing to the original plan, PTV coverage was compromised significantly in DCT plans (82% ± 7%) while all ART plans preserved PTV coverage. ART plans showed similar OAR sparing as the original plan, such as V40Gy=11.2cc (ART) vs 11.4cc (original) for the rectum and D10cc=4580cGy vs 4605cGy for the bladder. The sparing of the rectum/bladder depends on overlap ratios. The sparing in ART was either similar or improved when overlap ratios in treatment CTs were smaller than those in original plan. Conclusion: A partial optimization method is developed that may make the real-time ART feasible on selected patients. Future research is warranted to quantify the applicability of the proposed method.« less
Control of hypertension with single daily doses of sotalol hydrochloride.
Gabriel, R
A study was carried out in 12 previously untreated hypertensive patients to assess the efficacy of sotalol given in a once-daily dosage regimen. After an initial dosage titration period (mean 3 weeks) during which diastolic pressure was stabilized at less than 100 mmHg, all patients were satisfactorily maintained on a constant once-daily dose of sotalol for 3 months. Eight of the 12 patients required 320 mg or less daily (mean dose 190 mg). Whilst blood pressure remained controlled for at least 26 hours after daily doses the pulse rate, counted at the same time, showed escape from beta-blockade. Side-effects (vivid dreams) were reported in only 1 patient.
Estimation of child vaccination coverage at state and national levels in India
Gupta, Satish; Kumar, Rakesh; Haldar, Pradeep; Sethi, Raman; Bahl, Sunil
2016-01-01
Abstract Objective To review the data, for 1999–2013, on state-level child vaccination coverage in India and provide estimates of coverage at state and national levels. Methods We collated data from administrative reports, population-based surveys and other sources and used them to produce annual estimates of vaccination coverage. We investigated bacille Calmette–Guérin vaccine, the first and third doses of vaccine against diphtheria, tetanus and pertussis, the third dose of oral polio vaccine and the first dose of vaccine against measles. We obtained relevant data covering the period 1999–2013 for each of 16 states and territories and the period 2001–2013 for the state of Jharkhand – which was only created in 2000. We aggregated the resultant state-level estimates, using a population-weighted approach, to give national values. Findings For each of the vaccinations we investigated, about half of the 253 estimates of annual coverage at state level that we produced were based on survey results. The rest were based on interpolation between – or extrapolation from – so-called anchor points or, more rarely, on administrative data. Our national estimates indicated that, for each of the vaccines we investigated, coverage gradually increased between 1999 and 2010 but then levelled off. Conclusion The delivery of routine vaccination services to Indian children appears to have improved between 1999 and 2013. There remains considerable scope to improve the recording and reporting of childhood vaccination coverage in India and regular systematic reviews of the coverage data are recommended. PMID:27843162
Risk in daily newspaper coverage of red tide blooms in Southwest Florida
Li, Zongchao; Garrison, Bruce; Ullmann, Steven G.; Kirkpatrick, Barbara; Fleming, Lora E.; Hoagland, Porter
2016-01-01
This study investigated newspaper coverage of Florida red tide blooms in four metropolitan areas of Southwest Florida during a 25-year period, 1987-2012. We focused on how journalists framed red tide stories with respect to environmental risk, health risk, and economic risk. We determined risk to be a key factor in this news coverage, being an aspect of coverage of red tide itself in terms of environmental risk, tourism risk, and public health risk. The study found that red tide news coverage is most often framed as an environmental story. PMID:27087790
Buschmann, Martin; Majercakova, Katarina; Sturdza, Alina; Smet, Stephanie; Najjari, Dina; Daniel, Michaela; Pötter, Richard; Georg, Dietmar; Seppenwoolde, Yvette
2017-10-12
Radiotherapy for cervix cancer is challenging in patients exhibiting large daily changes in the pelvic anatomy, therefore adaptive treatments (ART) have been proposed. The aim of this study was the clinical implementation and subsequent evaluation of plan-of-the-day (POTD)-ART for cervix cancer in supine positioning. The described workflow was based on standard commercial equipment and current quality assurance (QA) methods. A POTD strategy, which employs a VMAT plan library consisting of an empty bladder plan, a full bladder plan and a motion robust backup plan, was developed. Daily adaption was guided by cone beam computed tomography (CBCT) imaging after which the best plan from the library was selected. Sixteen patients were recruited in a clinical study on ART, for nine POTD was applied due to their large organ motion derived from two computed tomography (CT) scans with variable bladder filling. All patients were treated to 45Gy in 25 fractions. Plan selection frequencies over the treatment course were analyzed. Daily doses in the rectum, bladder and cervix-uterus target (CTV-T) were derived and compared to a simulated non-adapted treatment (non-ART), which employed the robust plan for each fraction. Additionally, the adaption consistency was determined by repeating the plan selection procedure one month after treatment by a group of experts. ART-specific QA methods are presented. 225 ART fractions with CBCTs were analyzed. The empty bladder plan was delivered in 49% of the fractions in the first treatment week and this number increased to 78% in the fifth week. The daily coverage of the CTV-T was equivalent between ART and the non-ART simulation, while the daily total irradiated volume V42.75Gy (95% of prescription dose) was reduced by a median of 87cm 3 . The median delivered V42.75Gy was 1782cm 3 . Daily delivered doses (V42.75Gy, V40Gy, V30G) to the organs at risk were statistically significantly reduced by ART, with a median difference in daily V42.75Gy in rectum and bladder of 3.2% and 1.1%, respectively. The daily bladder V42.75Gy and V40Gy were decreased by more than 10 percent points in 30% and 24% of all fractions, respectively, through ART. The agreement between delivered plans and retrospective expert-group plan selections was 84%. A POTD-ART technique for cervix cancer was successfully and safely implemented in the clinic and evaluated. Improved normal tissue sparing compared to a simulated non-ART treatment could be demonstrated. Future developments should focus on commercial automated software solutions to allow for a more widespread adoption and to keep the increased workload manageable. Copyright © 2017. Published by Elsevier GmbH.
Tohme, Rania A; François, Jeannot; Wannemuehler, Kathleen; Iyengar, Preetha; Dismer, Amber; Adrien, Paul; Hyde, Terri B; Marston, Barbara J; Date, Kashmira; Mintz, Eric; Katz, Mark A
2015-06-01
In 2013, the first government-led oral cholera vaccination (OCV) campaign in Haiti was implemented in Petite Anse and Cerca Carvajal. To evaluate vaccination coverage, barriers to vaccination, and adverse events following vaccination, we conducted a cluster survey. We enrolled 1,121 persons from Petite Anse and 809 persons from Cerca Carvajal, categorized by 3 age groups (1-4, 5-14, >15 years). Two-dose OCV coverage was 62.5% in Petite Anse and 76.8% in Cerca Carvajal. Two-dose coverage was lowest among persons >15 years of age. In Cerca Carvajal, coverage was significantly lower for male than female respondents (69% vs. 85%; p<0.001). No major adverse events were reported. The main reason for nonvaccination was absence during the campaign. Vaccination coverage after this campaign was acceptable and comparable to that resulting from campaigns implemented by nongovernmental organizations. Future campaigns should be tailored to reach adults who are not available during daytime hours.
SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, J; Gueorguiev, G; Grassberger, C
2015-06-15
Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: Themore » water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.« less
Vugmeyster, Yulia; Rohde, Cynthia; Perreault, Mylene; Gimeno, Ruth E; Singh, Pratap
2013-01-01
TAM-163, an agonist monoclonal antibody targeting tyrosine receptor kinase-B (TrkB), is currently being investigated as a potential body weight modulatory agent in humans. To support the selection of the dose range for the first-in-human (FIH) trial of TAM-163, we conducted a mechanistic analysis of the pharmacokinetic (PK) and pharmacodynamic (PD) data (e.g., body weight gain) obtained in lean cynomolgus and obese rhesus monkeys following single doses ranging from 0.3 to 60 mg/kg. A target-mediated drug disposition (TMDD) model was used to describe the observed nonlinear PK and Emax approach was used to describe the observed dose-dependent PD effect. The TMDD model development was supported by the experimental determination of the binding affinity constant (9.4 nM) and internalization rate of the drug-target complex (2.08 h(-1)). These mechanistic analyses enabled linking of exposure, target (TrkB) coverage, and pharmacological activity (e.g., PD) in monkeys, and indicated that ≥ 38% target coverage (time-average) was required to achieve significant body weight gain in monkeys. Based on the scaling of the TMDD model from monkeys to humans and assuming similar relationship between the target coverage and pharmacological activity between monkey and humans, subcutaneous (SC) doses of 1 and 15 mg/kg in humans were projected to be the minimally and the fully pharmacologically active doses, respectively. Based on the minimal anticipated biological effect level (MABEL) approach for starting dose selection, the dose of 0.05 mg/kg (3 mg for a 60 kg human) SC was recommended as the starting dose for FIH trials, because at this dose level<10% target coverage was projected at Cmax (and all other time points). This study illustrates a rational mechanistic approach for the selection of FIH dose range for a therapeutic protein with a complex model of action.
Analysis of esophageal-sparing treatment plans for patients with high-grade esophagitis.
Niedzielski, Joshua; Bluett, Jaques B; Williamson, Ryan T; Liao, Zhongxing; Gomez, Daniel R; Court, Laurence E
2013-07-08
We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three-dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm(3), respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans' mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm(3), respectively, compared with the clinical plans. The normalized plans' mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints.
Analysis of esophageal‐sparing treatment plans for patients with high‐grade esophagitis
Bluett, Jaques B.; Williamson, Ryan T.; Liao, Zhongxing; Gomez, Daniel R.; Court, Laurence E.
2013-01-01
We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11‐beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three‐dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm3, respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans’ mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm3, respectively, compared with the clinical plans. The normalized plans’ mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints. PACS number: 87.53 Tf PMID:23835390
Chen, Li; Du, Xiaozhen; Zhang, Lin; van Velthoven, Michelle Helena; Wu, Qiong; Yang, Ruikan; Cao, Ying; Wang, Wei; Xie, Lihui; Rao, Xiuqin; Zhang, Yanfeng; Koepsell, Jeanne Catherine
2016-08-31
The aim of this study was to assess the effectiveness of an EPI smartphone application (EPI app) on improving vaccination coverage in rural Sichuan Province, China. This matched-pair cluster randomized controlled study included 32 village doctors, matched in 16 pairs, and took place from 2013 to 2015. Village doctors in the intervention group used the EPI app and reminder text messages while village doctors in the control group used their usual procedures and text messages. The primary outcome was full vaccination coverage with all five vaccines (1 dose of BCG, 3 doses of hepatitis B, 3 doses of OPV, 3 doses of DPT and 1 dose of measles vaccine), and the secondary outcome was coverage with each dose of the five individual vaccines. We also conducted qualitative interviews with village doctors to understand perceptions on using the EPI app and how this changed their vaccination work. The full vaccination coverage increased statistically significant from baseline to end-line in both the intervention (67 % [95 % CI:58-75 %] to 84 % [95 % CI:76-90 %], P = 0.028) and control group (71 % [95 % CI:62-79 %] to 82 % [95 % CI:74-88 %], P = 0.014). The intervention group had higher increase in full vaccination coverage from baseline to end-line compared to the control group (17 % vs 10 %), but this was not statistically significant (P = 0.164). Village doctors found it more convenient to use the EPI app to manage child vaccination and also reported saving time by looking up information of caregivers and contacting caregivers for overdue vaccinations quicker. However, village doctors found it hard to manage children who migrated out of the counties. This study showed that an app and text messages can be used by village doctors to improve full vaccination coverage, though no significant increase in vaccination coverage was found when assessing the effect of the app on its own. Village doctors using EPI app reported having improved their working efficiency of managing childhood vaccination. Future studies should be conducted to evaluate the impact of more integrated approach of mHealth intervention on child immunization. Chinese Clinical Trials Registry (ChiCTR): ChiCTR-TRC- 13003960 , registered on December 6, 2013.
TES/Aura L3 Atmospheric Temperatures Daily V5 (TL3ATD)
Atmospheric Science Data Center
2018-05-08
... Platform: TES Aura L1B Nadir/Limb Spatial Coverage: (-180, 180)(-90, 90) Spatial Resolution: 0.5 x 5 km nadir 2.3 x 23 km limb Temporal Coverage: 07/15/2004 - Present Temporal Resolution: ...
2016-01-01
This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5–30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ±2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ±15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ±3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI. PACS numbers: 87.55.km, 87.56.Fc PMID:26894347
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang-Chesebro, Alice; Xia Ping; Coleman, Joy
2006-11-01
Purpose: The aim of this study was to quantify gains in lymph node coverage and critical structure dose reduction for whole-pelvis (WP) and extended-field (EF) radiotherapy in prostate cancer using intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3DCRT) for the first treatment phase of 45 Gy in the concurrent treatment of lymph nodes and prostate. Methods and Materials: From January to August 2005, 35 patients with localized prostate cancer were treated with pelvic IMRT; 7 had nodes defined up to L5-S1 (Group 1), and 28 had nodes defined above L5-S1 (Group 2). Each patient had 2 plans retrospectively generated:more » 1 WP 3DCRT plan using bony landmarks, and 1 EF 3DCRT plan to cover the vascular defined volumes. Dose-volume histograms for the lymph nodes, rectum, bladder, small bowel, and penile bulb were compared by group. Results: For Group 1, WP 3DCRT missed 25% of pelvic nodes with the prescribed dose 45 Gy and missed 18% with the 95% prescribed dose 42.75 Gy, whereas WP IMRT achieved V{sub 45Gy} = 98% and V{sub 42.75Gy} = 100%. Compared with WP 3DCRT, IMRT reduced bladder V{sub 45Gy} by 78%, rectum V{sub 45Gy} by 48%, and small bowel V{sub 45Gy} by 232 cm{sup 3}. EF 3DCRT achieved 95% coverage of nodes for all patients at high cost to critical structures. For Group 2, IMRT decreased bladder V{sub 45Gy} by 90%, rectum V{sub 45Gy} by 54% and small bowel V{sub 45Gy} by 455 cm{sup 3} compared with EF 3DCRT. Conclusion: In this study WP 3DCRT missed a significant percentage of pelvic nodes. Although EF 3DCRT achieved 95% pelvic nodal coverage, it increased critical structure doses. IMRT improved pelvic nodal coverage while decreasing dose to bladder, rectum, small bowel, and penile bulb. For patients with extended node involvement, IMRT especially decreases small bowel dose.« less
Gugsa, Frey; Karmarkar, Ellora; Cheyne, Andrew; Yamey, Gavin
2016-01-01
Objective To examine newspaper coverage of maternal health in three countries that have made varying progress towards Millennium Development Goal 5 (MDG 5): Bangladesh (on track), Rwanda (making progress, but not on track) and South Africa (no progress). Design We analysed each country's leading national English-language newspaper: Bangladesh's The Daily Star, Rwanda's The New Times/The Sunday Times, and South Africa's Sunday Times/The Times. We quantified the number of maternal health articles published from 1 January 2008 to 31 March 2013. We conducted a content analysis of subset of 190 articles published from 1 October 2010 to 31 March 2013. Results Bangladesh's The Daily Star published 579 articles related to maternal health from 1 January 2008 to 31 March 2013, compared to 342 in Rwanda's The New Times/The Sunday Times and 253 in South Africa's Sunday Times/The Times over the same time period. The Daily Star had the highest proportion of stories advocating for or raising awareness of maternal health. Most maternal health articles in The Daily Star (83%) and The New Times/The Sunday Times (69%) used a ‘human-rights’ or ‘policy-based’ frame compared to 41% of articles from Sunday Times/The Times. Conclusions In the three countries included in this study, which are on different trajectories towards MDG 5, there were differences in the frequency, tone and content of their newspaper coverage of maternal health. However, no causal conclusions can be drawn about this association between progress on MDG 5 and the amount and type of media coverage of maternal health. PMID:26769780
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.
2011-02-15
Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.« less
Xu, Huijun; Gordon, J James; Siebers, Jeffrey V
2011-02-01
A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The accuracy of coverage estimates depends on angular and radial DMD sampling parameters omega or omega eff and delta, as well as the employed sampling technique. Target deltaQ/ < l% and OAR /deltaQ/ < 3% can be achieved with sampling parameters omega or omega eef = 20 degrees, delta =1 mm. Better accuracy (target /deltaQ < 0.5% and OAR /deltaQ < approximately 1%) can be achieved with omega or omega eff = 10 degrees, delta = 0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with omega or omega eff = 10 degrees and delta = 0.5 mm should be adequate for planning purposes.
NASA Astrophysics Data System (ADS)
de La Casinière, A.; Touré, M. L.; Masserot, D.; Lenoble, J.; Cabot, T.; Pinedo Vega, J. L.
Global UV irradiance spectra we re recorded each half an hour between sunrise and sunset, along the year 2000 in Briançon (1300m asl) at the CEMBREU (Centre Européen Médical Bioclimatique de Recherche et d'Enseignement Universitaire), a site of the French spectral UV network in Southern Alps. From these spectra are retrieved atmospheric transmissivities corresponding to daily doses of various biologically active radiation. A transmissivity is defined as the ratio of the ground level value of a daily dose to the extra -atmospheric value of this daily dose. The daily doses studied relate to UVB, erythema, DNA damage, and plant damage. Multiple linear correlations of the various transmissivities with the three predictors (daily sunshine fraction), µmin (cosine of the daily minimum SZA), and (daily total ozone column) assumed to be independent variables, are done for year 2000. These correlations permit to assess the mean sensitivities of the various transmissivities, to changes in for different cloud cover conditions in Briançon. The variations of each sensitivity is studied as a function of , µmin and . Comparing the results obtained with those given in the literature, we find for = 1 (that is for a strong probability of clear sky conditions) and SZA min = 45°, a radiation amplification factor (RAF) of the erythemal daily dose equal to 1.1 when = 285 DU, and to 1.4 when = 315 DU.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krayenbuehl, Jerome; Hartmann, Matthias; Lomax, Anthony J.
Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The meanmore » dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.« less
Fakih, Marwan G; Fetterly, Gerald; Egorin, Merrill J; Muindi, Josephia R; Espinoza-Delgado, Igor; Zwiebel, James A; Litwin, Alan; Holleran, Julianne L; Wang, Kangsheng; Diasio, Robert B
2010-07-15
We conducted a phase I clinical trial to determine the maximum tolerated dose (MTD) of daily or twice daily vorinostat x 3 days when combined with fixed doses of 5-fluorouracil (FU) and leucovorin every 2 weeks. Vorinostat doses were escalated in a standard 3 x 3 phase I design. FU/leucovorin was started on day 2 of vorinostat and consisted of leucovorin 400 mg/m(2) i.v. over 2 hours followed by FU 400 mg/m(2) i.v. bolus and 2,400 mg/m(2) over 46 hours (sLV5FU2). Forty-three patients were enrolled. Grade 3 fatigue, and hand and foot syndrome were the dose-limiting toxicities (DLT) at the 2,000 mg vorinostat once-daily dose level. Grade 3 fatigue and mucositis were DLTs at the 800 mg vorinostat twice-daily dose level. None of six patients at the 1,700 mg once daily or six patients at the 600 mg twice daily dose levels had a DLT; those dose levels represent the MTD. Twenty-one of 38 patients with FU-refractory colorectal cancer had stable disease, and one had a partial response. Vorinostat maximum serum concentrations at the MTD exceeded concentrations associated with thymidylate synthase downregulation in vitro. No pharmacokinetic interactions were noted between vorinostat and FU. The MTD of vorinostat in combination with sLV5FU2 is 1,700 mg orally once daily x 3 or 600 mg orally twice daily x 3 days every 2 weeks. Clinical activity in refractory colorectal cancer supports further clinical development of this combination. Copyrighth 2010 AACR.
Fakih, Marwan G.; Fetterly, Gerald; Egorin, Merrill J.; Muindi, Josephia R.; Espinoza-Delgado, Igor; Zwiebel, James A.; Litwin, Alan; Holleran, Julianne L.; Wang, Kangsheng; Diasio, Robert B.
2010-01-01
Purpose We conducted a phase I clinical trial to determine the maximum tolerated dose (MTD) of daily or twice daily vorinostat × 3 days when combined with fixed doses of 5-fluorouracil (FU) and leucovorin every 2 weeks. Experimental Design Vorinostat doses were escalated in a standard 3 × 3 phase I design. FU/leucovorin was started on day 2 of vorinostat and consisted of leucovorin 400 mg/m2 i.v. over 2 hours followed by FU 400 mg/m2 i.v. bolus and 2,400 mg/m2 over 46 hours (sLV5FU2). Results Forty-three patients were enrolled. Grade 3 fatigue, and hand and foot syndrome were the dose-limiting toxicities (DLT) at the 2,000 mg vorinostat once-daily dose level. Grade 3 fatigue and mucositis were DLTs at the 800 mg vorinostat twice-daily dose level. None of six patients at the 1,700 mg once daily or six patients at the 600 mg twice daily dose levels had a DLT; those dose levels represent the MTD. Twenty-one of 38 patients with FU-refractory colorectal cancer had stable disease, and one had a partial response. Vorinostat maximum serum concentrations at the MTD exceeded concentrations associated with thymidylate synthase downregulation in vitro. No pharmacokinetic interactions were noted between vorinostat and FU. Conclusions The MTD of vorinostat in combination with sLV5FU2 is 1,700 mg orally once daily × 3 or 600 mg orally twice daily × 3 days every 2 weeks. Clinical activity in refractory colorectal cancer supports further clinical development of this combination. PMID:20463088
NSW annual immunisation coverage report, 2010.
Hull, Brynley; Dey, Aditi; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B
2011-11-01
This annual report, the second in the series, documents trends in immunisation coverage in NSW for children, adolescents and the elderly, to the end of 2010. Data from the Australian Childhood Immunisation Register, the NSW School Immunisation Program and the NSW Population Health Survey were used to calculate various measures of population coverage, coverage for Aboriginal children and vaccination timeliness for all children. Over 90% coverage has been reached for children at 12 and 24 months of age. For children at 5 years of age there was an improvement during 2010 in timeliness for vaccines due at 4 years and coverage almost reached 90%. Delayed receipt of vaccines is still an issue for Aboriginal children. For adolescents, there is good coverage for the first and second doses of human papillomavirus vaccine and the dose of diphtheria, tetanus and acellular pertussis. The pneumococcal vaccination rate in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. Completion of the recommended immunisation schedule at the earliest appropriate age should be the next public health goal at both the state and local health district level. Official coverage assessments for 'fully immunised' should include the 7-valent pneumococcal conjugate and meningococcal C vaccines, and wider dissemination should be considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, L; Ballangrud, A; Mechalakos, J
Purpose: For left-sided PU patients requiring CW and nodal irradiation, sometimes partial wide tangents (PWT) are not feasible due to abnormal chest wall contour or heart position close to the anterior chest wall or unusual wide excision scar. We developed an energy modulated electron chest wall irradiation technique that will achieve heart sparing. Methods: Ten left-sided PU patients were selected for this dosimetry study. If PWT were used, the amount of the ipsilateral lung would be ranged 3.4 to 4.4 cm, and the amount of heart would be ranged 1.3 to 3.8 cm. We used electron paired fields that matchedmore » on the skin to achieve dose conformity to the chest wall. The enface electron fields were designed at extended SSD from a single isocenter and gantry angle with different energy beams using different cutout. Lower energy was used in the central chest wall part and higher energy was used in the periphery of the chest wall. Bolus was used for the electron fields to ensure adequate skin dose coverage. The electron fields were matched to the photon supra-clavicle field in the superior region. Daily field junctions were used to feather the match lines between all the fields. Target volumes and normal tissues were drawn according to institutional protocols. Prescription dose was 2Gy per fraction for a total 50Gy. Dose calculations were done with Eclipse EMC-11031 for Electron and AAA-11031 for photons. Results: Six patients were planned using 6/9MeV, three using 9/12MeV and one 6/12MeV. Target volumes achieved adequate coverage. For heart, V30Gy, V20Gy and Mean Dose were 0.6%±0.6%, 2.7%±1.7%, and 3.0Gy±0.8Gy respectively. For ipsilateral lung, V50Gy, V20Gy, V10Gy and V5Gy were 0.9%±1.1%, 34.3%±5.1%, 51.6%±6.3% and 64.1%±7.5% respectively. Conclusion: For left-sided PU patients with unusual anatomy, energy modulated electron CW irradiation technique can achieve heart sparing with acceptable lung dose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galavis, P; Barbee, D; Jozsef, G
2016-06-15
Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspotsmore » using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, S; Sehgal, V; Wei, R
2015-06-15
Purpose: The aim of this study is to quantify dosimetric effects resulting from variation in pancreatic tumor position assessed by bony anatomy and implanted fiducial markers Methods: Twelve pancreatic cancer patients were retrospectively analyzed for this study. All patients received modulated arc therapy (VMAT) treatment using fiducial-based Image Guided Radiation Therapy (IGRT) to the intact pancreas. Using daily orthogonal kV and/or Cone beam CT images, the shift needed to co-register the daily pre-treatment images to reference CT from fiducial to bone (Fid-Bone) were recorded as Left-Right (LR), Anterior-Posterior (AP) and Superior-Inferior (SI). The original VMAT plan iso-center was shifted basedmore » on KV bone matching positions at 5 evenly spaced fractions. Dose coverage of the planning target volumes (PTVs) (V100%), mean dose to liver, kidney and stomach/duodenum were assessed in the modified plans. Results: A total of 306 fractions were analyzed. The absolute fiducial-bone positional shifts were greatest in the SI direction, (AP = 2.7 ± 3.0, LR = 2.8 ± 2.8, and SI 6.3 ± 7.9 mm, mean ± SD). The V100% was significantly reduced by 13.5%, (Fid-Bone = 95.3 ± 2.0 vs. 82.3 ± 11.8%, p=0.02). This varied widely among patients (Fid-Bone V100% Range = 2–60%), where 33% of patients had a reduction in V100% of more than 10%. The impact on OARs was greatest to the liver (Fid-Bone= 14.6 vs. 16.1 Gy, 10%), and stomach, (Fid-Bone = 23.9 vx. 25.5 Gy, 7%), however was not statistically significant (p=0.10 both). Conclusion: Compared to matching by fiducial markers, matching by bony anatomy would have substantially reduced the PTV coverage by 13.5%. This reinforces the importance of online position verification based on fiducial markers. Hence, implantation of fiducial markers is strongly recommended for pancreatic cancer patients undergoing intensity modulated radiation therapy treatments.« less
Coverage of childhood vaccination among children aged 12-23 months, Tamil Nadu, 2015, India
Murhekar, Manoj V.; Kamaraj, P.; Kanagasabai, K.; Elavarasu, G.; Rajasekar, T. Daniel; Boopathi, K.; Mehendale, Sanjay
2017-01-01
Background & objectives: District-Level Household Survey-4 (DLHS-4) indicated that during 2012-2013, only 56 per cent of children aged 12-23 months in Tamil Nadu were fully vaccinated, which were lesser than those reported in earlier national surveys. We, therefore, conducted cluster surveys to estimate coverage of childhood vaccination in the State, and also to identify the factors associated with low coverage. Methods: Cross-sectional surveys were conducted in 15 strata [municipal corporation non-slum (n=1), municipal corporation slum (n=1), hilly (n=1), rural (n=6) and urban (n=6)]. From each stratum, 30 clusters were selected using probability proportional to the population size linear systematic sampling; seven children aged 12-23 months were selected from each cluster and their mothers/care-takers were interviewed to collect information about vaccination status of the child. A child was considered fully vaccinated if he/she received bacillus Calmette-Guérin (BCG), three doses of pentavalent, three doses of oral polio vaccine and one dose of measles vaccine, and appropriately vaccinated if all vaccine doses were given at right age and with right interval. Further, coverage of fully vaccinated children (FVC) as per vaccination cards or mothers’ recall, validated coverage of FVC (V-FVC) among those having cards, and coverage of appropriately vaccinated children (AVC) were estimated using survey data analysis module with appropriate sampling weights. Results: A total of 3150 children were surveyed, of them 2528 (80.3%) had vaccination card. The weighted coverage of FVC, V-FVC and AVC in the State was 79.9 per cent [95% confidence interval (CI): 78.2-81.5], 78.8 per cent (95% CI: 76.9-80.5) and 69.7 per cent (95% CI: 67.7-71.7), respectively. The coverage of individual vaccine ranged between 84 per cent (measles) and 99.8 per cent (BCG). About 12 per cent V-FVC were not vaccinated as per the vaccination schedule. Interpretation & conclusions: The coverage of FVC in Tamil Nadu was high, with about 80 per cent children completing primary vaccination. Efforts to increase vaccination coverage in the State need to focus on educating vaccinators about the need to adhere to the national vaccination schedule and strengthening supervision to ensure that children are vaccinated appropriately. PMID:28749402
Coverage of childhood vaccination among children aged 12-23 months, Tamil Nadu, 2015, India.
Murhekar, Manoj V; Kamaraj, P; Kanagasabai, K; Elavarasu, G; Rajasekar, T Daniel; Boopathi, K; Mehendale, Sanjay
2017-03-01
District-Level Household Survey-4 (DLHS-4) indicated that during 2012-2013, only 56 per cent of children aged 12-23 months in Tamil Nadu were fully vaccinated, which were lesser than those reported in earlier national surveys. We, therefore, conducted cluster surveys to estimate coverage of childhood vaccination in the State, and also to identify the factors associated with low coverage. Cross-sectional surveys were conducted in 15 strata [municipal corporation non-slum (n=1), municipal corporation slum (n=1), hilly (n=1), rural (n=6) and urban (n=6)]. From each stratum, 30 clusters were selected using probability proportional to the population size linear systematic sampling; seven children aged 12-23 months were selected from each cluster and their mothers/care-takers were interviewed to collect information about vaccination status of the child. A child was considered fully vaccinated if he/she received bacillus Calmette-Guérin (BCG), three doses of pentavalent, three doses of oral polio vaccine and one dose of measles vaccine, and appropriately vaccinated if all vaccine doses were given at right age and with right interval. Further, coverage of fully vaccinated children (FVC) as per vaccination cards or mothers' recall, validated coverage of FVC (V-FVC) among those having cards, and coverage of appropriately vaccinated children (AVC) were estimated using survey data analysis module with appropriate sampling weights. A total of 3150 children were surveyed, of them 2528 (80.3%) had vaccination card. The weighted coverage of FVC, V-FVC and AVC in the State was 79.9 per cent [95% confidence interval (CI): 78.2-81.5], 78.8 per cent (95% CI: 76.9-80.5) and 69.7 per cent (95% CI: 67.7-71.7), respectively. The coverage of individual vaccine ranged between 84 per cent (measles) and 99.8 per cent (BCG). About 12 per cent V-FVC were not vaccinated as per the vaccination schedule. The coverage of FVC in Tamil Nadu was high, with about 80 per cent children completing primary vaccination. Efforts to increase vaccination coverage in the State need to focus on educating vaccinators about the need to adhere to the national vaccination schedule and strengthening supervision to ensure that children are vaccinated appropriately.
Troeller, Almut; Garny, Sylvia; Pachmann, Sophia; Kantz, Steffi; Gerum, Sabine; Manapov, Farkhad; Ganswindt, Ute; Belka, Claus; Söhn, Matthias
2015-02-22
The use of high accuracy dose calculation algorithms, such as Monte Carlo (MC) and Collapsed Cone (CC) determine dose in inhomogeneous tissue more accurately than pencil beam (PB) algorithms. However, prescription protocols based on clinical experience with PB are often used for treatment plans calculated with CC. This may lead to treatment plans with changes in field size (FS) and changes in dose to organs at risk (OAR), especially for small tumor volumes in lung tissue treated with SABR. We re-evaluated 17 3D-conformal treatment plans for small intrapulmonary lesions with a prescription of 60 Gy in fractions of 7.5 Gy to the 80% isodose. All treatment plans were initially calculated in Oncentra MasterPlan® using a PB algorithm and recalculated with CC (CCre-calc). Furthermore, a CC-based plan with coverage similar to the PB plan (CCcov) and a CC plan with relaxed coverage criteria (CCclin), were created. The plans were analyzed in terms of Dmean, Dmin, Dmax and coverage for GTV, PTV and ITV. Changes in mean lung dose (MLD), V10Gy and V20Gy were evaluated for the lungs. The re-planned CC plans were compared to the original PB plans regarding changes in total monitor units (MU) and average FS. When PB plans were recalculated with CC, the average V60Gy of GTV, ITV and PTV decreased by 13.2%, 19.9% and 41.4%, respectively. Average Dmean decreased by 9% (GTV), 11.6% (ITV) and 14.2% (PTV). Dmin decreased by 18.5% (GTV), 21.3% (ITV) and 17.5% (PTV). Dmax declined by 7.5%. PTV coverage correlated with PTV volume (p < 0.001). MLD, V10Gy, and V20Gy were significantly reduced in the CC plans. Both, CCcov and CCclin had significantly increased MUs and FS compared to PB. Recalculation of PB plans for small lung lesions with CC showed a strong decline in dose and coverage in GTV, ITV and PTV, and declined dose in the lung. Thus, switching from a PB algorithm to CC, while aiming to obtain similar target coverage, can be associated with application of more MU and extension of radiotherapy fields, causing greater OAR exposition.
Ahmad, Hesham M
2015-01-01
Acne vulgaris is a debilitating disorder and requires proper treatment. This work evaluates the clinical efficacy, side effects, and laboratory changes of serum lipids and liver function during oral isotretinoin therapy for acne vulgaris, comparing single versus twice daily dose. Fifty-eight patients with acne vulgaris were included and randomized into group I (26 patients), who received once daily dose, and group II (32 patients), who received twice daily dose of oral isotretinoin. Global acne scoring system was used to evaluate acne severity and post-treatment improvement. Both regimens resulted in highly significant clinical improvement of acne with no significant difference. However, side effects were significantly more common among patients of group I. Both regimens caused mild rise of serum cholesterol, alanine transaminase (ALT), and aspartate aminotransferase (AST) with more prominent rise of triglycerides especially with twice daily dose. Oral isotretinoin is a very effective treatment for acne vulgaris with no statistically significant difference in clinical efficacy between once and twice daily doses. However, dividing dose to twice per day might cause fewer incidence of side effects without reducing clinical efficacy. The drug causes mild clinically insignificant rise of serum cholesterol, triglycerides, AST, and ALT. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Fraser, Danielle
In radiation therapy an uncertainty in the delivered dose always exists because anatomic changes are unpredictable and patient specific. Image guided radiation therapy (IGRT) relies on imaging in the treatment room to monitor the tumour and surrounding tissue to ensure their prescribed position in the radiation beam. The goal of this thesis was to determine the dosimetric impact on the misaligned radiation therapy target for three cancer sites due to common setup errors; organ motion, tumour tissue deformation, changes in body habitus, and treatment planning errors. For this purpose, a novel 3D ultrasound system (Restitu, Resonant Medical, Inc.) was used to acquire a reference image of the target in the computed tomography simulation room at the time of treatment planning, to acquire daily images in the treatment room at the time of treatment delivery, and to compare the daily images to the reference image. The measured differences in position and volume between daily and reference geometries were incorporated into Monte Carlo (MC) dose calculations. The EGSnrc (National Research Council, Canada) family of codes was used to model Varian linear accelerators and patient specific beam parameters, as well as to estimate the dose to the target and organs at risk under several different scenarios. After validating the necessity of MC dose calculations in the pelvic region, the impact of interfraction prostate motion, and subsequent patient realignment under the treatment beams, on the delivered dose was investigated. For 32 patients it is demonstrated that using 3D conformal radiation therapy techniques and a 7 mm margin, the prescribed dose to the prostate, rectum, and bladder is recovered within 0.5% of that planned when patient setup is corrected for prostate motion, despite the beams interacting with a new external surface and internal tissue boundaries. In collaboration with the manufacturer, the ultrasound system was adapted from transabdominal imaging to neck imaging. Two case studies of nasopharyngeal cancer are discussed. The deformation of disease-positive cervical lymph nodes was monitored throughout treatment. Node volumes shrunk to 17% of the initial volume, moved up 1.3 cm, and received up to a 12% lower dose than that prescribed. It is shown that difficulties in imaging soft tissue in the neck region are circumvented with ultrasound imaging, and after dosimetric verification it is argued that adaptive replanning may be more beneficial than patient realignment when intensity modulated radiation therapy techniques are used. Some of the largest dose delivery errors were found in external electron beam treatments for breast cancer patients who underwent breast conserving surgery. Inaccuracies in conventional treatment planning resulted in substantial target dose discrepancies of up to 88%. When patient setup errors, interfraction tumour bed motion, and tissue remodeling were considered, inadequate target coverage was exacerbated. This thesis quantifies the dose discrepancy between that prescribed and that delivered. I delve into detail for common IGRT treatment sites, and illuminate problems that have not received much attention for less common IGRT treatment sites.
Uptake and timeliness of rotavirus vaccination in Norway: The first year post-introduction.
Valcarcel Salamanca, Beatriz; Hagerup-Jenssen, Maria Elisabeth; Flem, Elmira
2016-09-07
To minimise vaccine-associated risk of intussusception following rotavirus vaccination, Norway adopted very strict age limits for initiating and completing the vaccine series at the time rotavirus vaccination was included in the national immunisation programme, October 2014. Although Norway has a high coverage for routine childhood vaccines, these stringent age limits could negatively affect rotavirus coverage. We documented the status and impact of rotavirus vaccination on other infant vaccines during the first year after its introduction. We used individual vaccination data from the national immunisation register to calculate coverage for rotavirus and other vaccines and examine adherence with the recommended schedules. We identified factors associated with completing the full rotavirus series by performing multiple logistic regression analyses. We also evaluated potential changes in uptake and timeliness of other routine vaccines after the introduction of rotavirus vaccine using the Kaplan-Meier method. The national coverage for rotavirus vaccine achieved a year after the introduction was 89% for one dose and 82% for two doses, respectively. Among fully rotavirus-vaccinated children, 98% received both doses within the upper age limit and 90% received both doses according to the recommended schedule. The child's age at the initiation of rotavirus series and being vaccinated with diphtheria, tetanus, pertussis, polio and Haemophilus influenzae type b (DTaP/IPV/Hib) and pneumococcal vaccines were the strongest predictors of completing the full rotavirus series. No major changes in uptake and timeliness of other paediatric vaccines were observed after introduction of rotavirus vaccine. Norway achieved a high national coverage and excellent adherence with the strict age limits for rotavirus vaccine administration during the first year of introduction, indicating robustness of the national immunisation programme. Rotavirus vaccination did not impact coverage or timeliness of other infant vaccines. Copyright © 2016. Published by Elsevier Ltd.
Recent resurgence of mumps in the United States.
Dayan, Gustavo H; Quinlisk, M Patricia; Parker, Amy A; Barskey, Albert E; Harris, Meghan L; Schwartz, Jennifer M Hill; Hunt, Kae; Finley, Carol G; Leschinsky, Dennis P; O'Keefe, Anne L; Clayton, Joshua; Kightlinger, Lon K; Dietle, Eden G; Berg, Jeffrey; Kenyon, Cynthia L; Goldstein, Susan T; Stokley, Shannon K; Redd, Susan B; Rota, Paul A; Rota, Jennifer; Bi, Daoling; Roush, Sandra W; Bridges, Carolyn B; Santibanez, Tammy A; Parashar, Umesh; Bellini, William J; Seward, Jane F
2008-04-10
The widespread use of a second dose of mumps vaccine among U.S. schoolchildren beginning in 1990 was followed by historically low reports of mumps cases. A 2010 elimination goal was established, but in 2006 the largest mumps outbreak in two decades occurred in the United States. We examined national data on mumps cases reported during 2006, detailed case data from the most highly affected states, and vaccination-coverage data from three nationwide surveys. A total of 6584 cases of mumps were reported in 2006, with 76% occurring between March and May. There were 85 hospitalizations, but no deaths were reported; 85% of patients lived in eight contiguous midwestern states. The national incidence of mumps was 2.2 per 100,000, with the highest incidence among persons 18 to 24 years of age (an incidence 3.7 times that of all other age groups combined). In a subgroup analysis, 83% of these patients reported current college attendance. Among patients in eight highly affected states with known vaccination status, 63% overall and 84% between the ages of 18 and 24 years had received two doses of mumps vaccine. For the 12 years preceding the outbreak, national coverage of one-dose mumps vaccination among preschoolers was 89% or more nationwide and 86% or more in highly affected states. In 2006, the national two-dose coverage among adolescents was 87%, the highest in U.S. history. Despite a high coverage rate with two doses of mumps-containing vaccine, a large mumps outbreak occurred, characterized by two-dose vaccine failure, particularly among midwestern college-age adults who probably received the second dose as schoolchildren. A more effective mumps vaccine or changes in vaccine policy may be needed to avert future outbreaks and achieve the elimination of mumps. Copyright 2008 Massachusetts Medical Society.
Vaccine exemptions and the kindergarten vaccination coverage gap.
Smith, Philip J; Shaw, Jana; Seither, Ranee; Lopez, Adriana; Hill, Holly A; Underwood, Mike; Knighton, Cynthia; Zhao, Zhen; Ravanam, Megha Shah; Greby, Stacie; Orenstein, Walter A
2017-09-25
Vaccination requirements for kindergarten entry vary by state, but all states require 2 doses of measles containing vaccine (MCV) at kindergarten entry. To assess (i) national MCV vaccination coverage for children who had attended kindergarten; (ii) the extent to which undervaccination after kindergarten entry is attributable to parents' requests for an exemption; (iii) the extent to which undervaccinated children had missed opportunities to be administered missing vaccine doses among children whose parent did not request an exemption; and (iv) the vaccination coverage gap between the "highest achievable" MCV coverage and actual MCV coverage among children who had attended kindergarten. A national survey of 1465 parents of 5-7year-old children was conducted during October 2013 through March 2014. Vaccination coverage estimates are based provider-reported vaccination histories. Children have a "missed opportunity" for MCV if they were not up-to-date and if there were dates on which other vaccines were administered but not MCV. The "highest achievable" MCV vaccination coverage rate is 100% minus the sum of the percentages of (i) undervaccinated children with parents who requested an exemption; and (ii) undervaccinated children with parents who did not request an exemption and whose vaccination statuses were assessed during a kindergarten grace period or period when they were provisionally enrolled in kindergarten. Among all children undervaccinated for MCV, 2.7% were attributable to having a parent who requested an exemption. Among children who were undervaccinated for MCV and whose parent did not request an exemption, 41.6% had a missed opportunity for MCV. The highest achievable MCV coverage was 98.6%, actual MCV coverage was 90.9%, and the kindergarten vaccination gap was 7.7%. Vaccination coverage may be increased by schools fully implementing state kindergarten vaccination laws, and by providers assessing children's vaccination status at every clinic visit, and administering missed vaccine doses. Published by Elsevier Ltd.
Morimoto, Takeyori; Nagashima, Hiroki; Morimoto, Yasuko; Tokuyama, Shogo
2017-01-01
Tazobactam/piperacillin (TAZ/PIPC) is a combination antibiotic frequently used to treat pneumonia. It has recently been reported that TAZ/PIPC worsens renal function in patients with existing renal impairment. Creatinine clearance is generally between 10 and 40 mL/min in Japanese patients, so TAZ/PIPC is given at a dose of 2.25 g three times daily or 4.5 g twice daily. If pneumonia is severe or intractable, the dose frequency may be increased to 2.25 g four times daily and 4.5 g three times daily. We examined the effect of these different dosing regimens on renal function. We studied a cohort of 57 patients with impaired renal function hospitalized with pneumonia and treated with TAZ/PIPC between January 2015 and November 2016. Patients were classified into four groups according to TAZ/PIPC dose: 2.25 g three times daily (Group A); 2.25 g four times daily (B); 4.5 g twice daily (C) and 4.5 g three times daily (D). We examined the frequency of acute kidney injury (AKI) and treatment effectiveness. In Groups A, B, C and D, AKI occurred in 5.6%, 0.0%, 25.0% and 38.5% of patient. In groups C and D, hydration and dose reduction were required to address early signs of impending AKI. Our findings suggest that the higher TAZ/PIPC dose of 4.5 g was responsible for the decline in renal function, even if the dose frequency was reduced.
One and three doses of propranolol a day in hypertension.
van den Brink, G; Boer, P; van Asten, P; Dorhout Mees, E J; Geyskes, G G
1980-01-01
In 26 patients with essential hypertension who were on continuous chlorthalidone therapy, 1 and 3 daily doses of propranolol were compared in a crossover study. Plasma propranolol levels and heart rates had larger daily fluctuations on single-dose therapy than on 3 times daily; plasma renin activity was more constant. There was no significant difference in blood pressures. Once-daily propranolol dosage was well tolerated and possibly gave less rise to the troublesome side effect of vivid dreaming.
Downscaling Surface Temperature Image with TsHARP
USDA-ARS?s Scientific Manuscript database
Daily evapotranspiration (ET) maps would significantly improve assessing crop water requirements, especially in the Texas High Plains (THP) where the supply of irrigation water is limited. Evapotranspireation maps derived from satellite data with daily coverage such as MODIS (Moderate Resolution Ima...
Redmond, Kristin J.; Achanta, Pragathi; Grossman, Stuart A.; Armour, Michael; Reyes, Juvenal; Kleinberg, Lawrence; Tryggestad, Erik; Quinones-Hinojosa, Alfredo
2015-01-01
Radiation therapy (RT) for brain tumors is associated with neurocognitive toxicity which may be a result of damage to neural progenitor cells (NPCs). We present a novel technique to limit the radiation dose to NPC without compromising tumor coverage. A study was performed in mice to examine the rationale and another was conducted in humans to determine its feasibility. C57BL/6 mice received localized radiation using a dedicated animal irradiation system with on-board CT imaging with either: (1) Radiation which spared NPC containing regions; (2) Radiation which did not spare these niches; or (3) Sham irradiation. Mice were sacrificed 24 h later and the brains were processed for immunohistochemical Ki-67 staining. For the human component of the study, 33 patients with primary brain tumors were evaluated. Two intensity modulated radiotherapy (IMRT) plans were retrospectively compared: a standard clinical plan and a plan which spares NPC regions while maintaining the same dose coverage of the tumor. The change in radiation dose to the contralateral NPC-containing regions was recorded. In the mouse model, non-NPC-sparing radiation treatment resulted in a significant decrease in the number of Ki67+ cells in dentate gyrus (DG) (P = 0.008) and subventricular zone (SVZ) (P = 0.005) compared to NPC-sparing radiation treatment. In NPC-sparing clinical plans, NPC regions received significantly lower radiation dose with no clinically relevant changes in tumor coverage. This novel radiation technique should significantly reduce radiation doses to NPC containing regions of the brain which may reduce neurocognitive deficits following RT for brain tumors. PMID:21327710
Eberlin, M; Otto, G; Krämer, I
2013-01-01
Compliance with immunosuppressive therapy plays a major role in the long-term success of liver transplantation. Thus, the development of strategies to promote compliance of liver transplant patients and its evaluation over time are of particular interest. The main objective of this study was to compare medication compliance rates among liver transplant patients over time after transplantation where switched from a twice- to once-daily tacrolimus-based regimen. Sixty-five liver transplant patients being administered tacrolimus-based therapy were classified into three subgroups with regard to time posttransplantation. Medication compliance with tacrolimus-based therapy was measured using an electronic medication event monitoring system over a 12-month period: for 6 months tacrolimus was administered twice-daily and for 6 months, once-daily. Dosing, taking, and timing compliance as well as drug holidays were compared intra-individually between twice- and once-daily intake and among the three subgroups. In addition, patient compliance and quality of life were evaluated using questionnaires. A per protocol analysis of electronically obtained data showed 63 patients to be eligible. The resulting dosing, taking, and timing compliance rates of the patients were higher during the once-daily dosing period. No significant differences in compliance rates with tacrolimus therapy were observed among three subgroups independent of the dosing regimen. More patients failed the correct timing of the evening compared to the morning dose. Missing doses occurred particularly during weekends. Compliance variables measured by questionnaires (Morisky score, self-report, Medication Experience Scale for Immunosuppressants (MESI) score) and the Hospital Anxiety and Depression Scale score were similar in the two dosing periods. The short-form health survey (SF-36) score was higher with once-daily intake. The high measured compliance rates did not vary significantly dependent upon the time after transplantation. Nevertheless, compliance rates were greater using once-daily tacrolimus dosing. Copyright © 2013 Elsevier Inc. All rights reserved.
Electron intensity modulation for mixed-beam radiation therapy with an x-ray multi-leaf collimator
NASA Astrophysics Data System (ADS)
Weinberg, Rebecca
The current standard treatment for head and neck cancer at our institution uses intensity-modulated x-ray therapy (IMRT), which improves target coverage and sparing of critical structures by delivering complex fluence patterns from a variety of beam directions to conform dose distributions to the shape of the target volume. The standard treatment for breast patients is field-in-field forward-planned IMRT, with initial tangential fields and additional reduced-weight tangents with blocking to minimize hot spots. For these treatment sites, the addition of electrons has the potential of improving target coverage and sparing of critical structures due to rapid dose falloff with depth and reduced exit dose. In this work, the use of mixed-beam therapy (MBT), i.e., combined intensity-modulated electron and x-ray beams using the x-ray multi-leaf collimator (MLC), was explored. The hypothesis of this study was that addition of intensity-modulated electron beams to existing clinical IMRT plans would produce MBT plans that were superior to the original IMRT plans for at least 50% of selected head and neck and 50% of breast cases. Dose calculations for electron beams collimated by the MLC were performed with Monte Carlo methods. An automation system was created to facilitate communication between the dose calculation engine and the treatment planning system. Energy and intensity modulation of the electron beams was accomplished by dividing the electron beams into 2x2-cm2 beamlets, which were then beam-weight optimized along with intensity-modulated x-ray beams. Treatment plans were optimized to obtain equivalent target dose coverage, and then compared with the original treatment plans. MBT treatment plans were evaluated by participating physicians with respect to target coverage, normal structure dose, and overall plan quality in comparison with original clinical plans. The physician evaluations did not support the hypothesis for either site, with MBT selected as superior in 1 out of the 15 head and neck cases (p=1) and 6 out of 18 breast cases (p=0.95). While MBT was not shown to be superior to IMRT, reductions were observed in doses to critical structures distal to the target along the electron beam direction and to non-target tissues, at the expense of target coverage and dose homogeneity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menten, MJ; Fast, MF; Nill, S
Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin:more » 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting clinical outcome in hypofractionated treatment protocols. Dynamic MLC tracking preserves tumor dose coverage even in the presence of extreme baseline drifts. We acknowledge financial and technical support of the MLC tracking research from Elekta AB. Research at ICR is supported by CRUK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR. MFF is supported by CRUK under Programme C33589/A19908.« less
Wheeler, Matthew W; Bailer, A John
2007-06-01
Model averaging (MA) has been proposed as a method of accounting for model uncertainty in benchmark dose (BMD) estimation. The technique has been used to average BMD dose estimates derived from dichotomous dose-response experiments, microbial dose-response experiments, as well as observational epidemiological studies. While MA is a promising tool for the risk assessor, a previous study suggested that the simple strategy of averaging individual models' BMD lower limits did not yield interval estimators that met nominal coverage levels in certain situations, and this performance was very sensitive to the underlying model space chosen. We present a different, more computationally intensive, approach in which the BMD is estimated using the average dose-response model and the corresponding benchmark dose lower bound (BMDL) is computed by bootstrapping. This method is illustrated with TiO(2) dose-response rat lung cancer data, and then systematically studied through an extensive Monte Carlo simulation. The results of this study suggest that the MA-BMD, estimated using this technique, performs better, in terms of bias and coverage, than the previous MA methodology. Further, the MA-BMDL achieves nominal coverage in most cases, and is superior to picking the "best fitting model" when estimating the benchmark dose. Although these results show utility of MA for benchmark dose risk estimation, they continue to highlight the importance of choosing an adequate model space as well as proper model fit diagnostics.
Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu
2013-01-01
Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584
TES/Aura L3 Atmospheric Temperatures Daily V4 (TL3ATD)
Atmospheric Science Data Center
2018-05-09
... Platform: TES Aura L1B Nadir/Limb Spatial Coverage: 5.3 x 8.5 km nadir 37 x 23 km limb Spatial ... 0.5 x 5 km nadir 2.3 x 23 km limb Temporal Coverage: 08/22/2004 - present Temporal Resolution: ...
Senni, Michele; McMurray, John J V; Wachter, Rolf; McIntyre, Hugh F; Reyes, Antonio; Majercak, Ivan; Andreka, Peter; Shehova-Yankova, Nina; Anand, Inder; Yilmaz, Mehmet B; Gogia, Harinder; Martinez-Selles, Manuel; Fischer, Steffen; Zilahi, Zsolt; Cosmi, Franco; Gelev, Valeri; Galve, Enrique; Gómez-Doblas, Juanjo J; Nociar, Jan; Radomska, Maria; Sokolova, Beata; Volterrani, Maurizio; Sarkar, Arnab; Reimund, Bernard; Chen, Fabian; Charney, Alan
2016-09-01
To assess the tolerability of initiating/uptitrating sacubitril/valsartan (LCZ696) from 50 to 200 mg twice daily (target dose) over 3 and 6 weeks in heart failure (HF) patients (ejection fraction ≤35%). A 5-day open-label run-in (sacubitril/valsartan 50 mg twice daily) preceded an 11-week, double-blind, randomization period [100 mg twice daily for 2 weeks followed by 200 mg twice daily ('condensed' regimen) vs. 50 mg twice daily for 2 weeks, 100 mg twice daily for 3 weeks, followed by 200 mg twice daily ('conservative' regimen)]. Patients were stratified by pre-study dose of angiotensin-converting enzyme inhibitor/angiotensin-receptor blocker (ACEI/ARB; low-dose stratum included ACEI/ARB-naïve patients). Of 540 patients entering run-in, 498 (92%) were randomized and 429 (86.1% of randomized) completed the study. Pre-defined tolerability criteria were hypotension, renal dysfunction and hyperkalaemia; and adjudicated angioedema, which occurred in ('condensed' vs. 'conservative') 9.7% vs. 8.4% (P = 0.570), 7.3% vs. 7.6% (P = 0.990), 7.7% vs. 4.4% (P = 0.114), and 0.0% vs. 0.8% of patients, respectively. Corresponding proportions for pre-defined systolic blood pressure <95 mmHg, serum potassium >5.5 mmol/L, and serum creatinine >3.0 mg/dL were 8.9% vs. 5.2% (P = 0.102), 7.3% vs. 4.0% (P = 0.097), and 0.4% vs. 0%, respectively. In total, 378 (76%) patients achieved and maintained sacubitril/valsartan 200 mg twice daily without dose interruption/down-titration over 12 weeks (77.8% vs. 84.3% for 'condensed' vs. 'conservative'; P = 0.078). Rates by ACEI/ARB pre-study dose stratification were 82.6% vs. 83.8% (P = 0.783) for high-dose/'condensed' vs. high-dose/'conservative' and 84.9% vs. 73.6% (P = 0.030) for low-dose/'conservative' vs. low-dose/'condensed'. Initiation/uptitration of sacubitril/valsartan from 50 to 200 mg twice daily over 3 or 6 weeks had a tolerability profile in line with other HF treatments. More gradual initiation/uptitration maximized attainment of target dose in the low-dose ACEI/ARB group. © 2016 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.
Bunnapradist, S; Ciechanowski, K; West-Thielke, P; Mulgaonkar, S; Rostaing, L; Vasudev, B; Budde, K
2013-03-01
Phase III noninferiority trial examining efficacy and safety of converting stable renal transplant recipients from twice-daily tacrolimus to a novel extended-release once-daily tacrolimus formulation (LCPT) with a controlled agglomeration technology. Controls maintained tacrolimus twice daily. The primary efficacy endpoint was proportion of patients with efficacy failures (death, graft failure, locally read biopsy-proven acute rejection [BPAR], or loss to follow-up) within 12 months. Starting LCPT dose was 30% lower (15% for blacks) than preconversion tacrolimus dose; target trough levels were 4-15 ng/mL. A total of 326 patients were randomized; the mITT population (n = 162 each group) was similar demographically in the two groups. Mean daily dose of LCPT was significantly (p < 0.0001) lower than preconversion tacrolimus dose at each visit; mean trough levels between groups were similar. There were four efficacy failures in each group; safety outcomes were similar between groups. Frequency of premature study drug discontinuation was LCPT: 12% versus tacrolimus twice daily: 5% (p = 0.028). LCPT demonstrated noninferiority to tacrolimus twice daily in efficacy failure rates. LCPT may offer a safe and effective alternative for converting patients to a once-daily formulation. Compared to currently available tacrolimus formulation, LCPT requires lower doses to achieve target trough levels. © Copyright 2012 The American Society of Transplantation and the American Society of Transplant Surgeons.
Weinhandl, Eric D; Nieman, Kimberly M; Gilbertson, David T; Collins, Allan J
2015-01-01
Cardiovascular disease is a common cause of hospitalization in dialysis patients. Daily hemodialysis improves some parameters of cardiovascular function, but whether it associates with lower hospitalization risk is unclear. Observational cohort study using US Renal Data System data. Medicare-enrolled daily (5 or 6 sessions weekly) home hemodialysis (HHD) patients initiating NxStage System One use from January 1, 2006, through December 31, 2009, and contemporary thrice-weekly in-center hemodialysis patients, matched 5 to 1. Daily HHD or thrice-weekly in-center hemodialysis. All-cause and cause-specific hospital admissions, hospital readmissions, and hospital days assessed from Medicare Part A claims. For 3,480 daily HHD and 17,400 thrice-weekly in-center hemodialysis patients in intention-to-treat analysis, the HR of all-cause admission for daily HHD versus in-center hemodialysis was 1.01 (95%CI, 0.98-1.03). Cause-specific admission HRs were 0.89 (95%CI, 0.86-0.93) for cardiovascular disease, 1.18 (95%CI, 1.13-1.23) for infection, 1.01 (95%CI, 0.93-1.09) for vascular access dysfunction, and 1.02 (95%CI, 0.99-1.06) for other morbidity. Regarding cardiovascular disease, first admission and readmission HRs for daily HHD versus in-center hemodialysis were 0.91 and 0.87, respectively. Regarding infection, first admission and readmission HRs were 1.35 and 1.03, respectively. Protective associations of daily HHD with heart failure and hypertensive disease were most pronounced, as were adverse associations of daily HHD with bacteremia/sepsis, cardiac infection, osteomyelitis, and vascular access infection. Results may be confounded by unmeasured factors, including vascular access type; information about dialysis frequency, duration, and dose was lacking; causes of admission may be misclassified; results may not apply to patients without Medicare coverage. All-cause hospitalization risk was similar in daily HHD and thrice-weekly in-center hemodialysis patients. However, risk of cardiovascular-related admission was lower with daily HHD, and risk of infection-related admission was higher. More attention should be afforded to infection in HHD patients. Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Gaber, A. Osama; Alloway, Rita R.; Bodziak, Kenneth; Kaplan, Bruce; Bunnapradist, Suphamai
2013-01-01
Background LCP-Tacro is an extended-release formulation of tacrolimus designed for once-daily dosing. Phase 1 studies demonstrated greater bioavailability to twice-daily tacrolimus capsules and no new safety concerns. Methods In this phase 2 study, adult stable kidney transplant patients on tacrolimus capsules (Prograf) twice-daily were converted to tacrolimus tablets (LCP-Tacro) once-daily; patients continued on LCP-Tacro once-daily for days 8 to 21; trough levels were to be maintained between 5 and 15 ng/mL; 24-hr pharmacokinetic assessments were done on days 7 (baseline pre-switch), 14, and 21. Results Forty-seven patients completed LCP-Tacro dosing per protocol. The mean conversion ratio was 0.71. Pharmacokinetic data demonstrated consistent exposure (AUC) at the lower conversion dose. Cmax (P=0.0001), Cmax/Cmin ratio (P<0.001), percent fluctuation (P<0.0001), and swing (P=0.0004) were significantly lower and Tmax significantly (P<0.001) longer for LCP-Tacro versus Prograf. AUC24 and Cmin correlation coefficients after 7 and 14 days of therapy were 0.86 or more, demonstrating a robust correlation between LCP-Tacro tacrolimus exposure and trough levels. There were three serious adverse events; none were related to study drug and all were resolved. Conclusions Stable kidney transplant patients can be safely converted from Prograf twice-daily to LCP-Tacro. The greater bioavailability of LCP-Tacro allows for once-daily dosing and similar (AUC) exposure at a dose approximately 30% less than the total daily dose of Prograf. LCP-Tacro displays flatter kinetics characterized by significantly lower peak-trough fluctuations. PMID:23715050
Hull, Brynley P; Dey, Aditi; Menzies, Rob I; Brotherton, Julia M; McIntyre, Peter B
2014-09-30
This, the 6th annual immunisation coverage report, documents trends during 2012 for a range of standard measures derived from Australian Childhood Immunisation Register (ACIR) data, and National Human Papillomavirus (HPV) Vaccination Program Register data. These include coverage at standard age milestones and for individual vaccines included on the National Immunisation Program (NIP) and coverage in adolescents and adults. The proportion of Australian children 'fully vaccinated' at 12, 24 and 60 months of age was 91.7%, 92.5% and 91.2%, respectively. For vaccines available on the NIP but not assessed during 2012 for 'fully vaccinated' status or for eligibility for incentive payments (rotavirus and pneumococcal at 12 months and meningococcal C and varicella at 24 months) coverage varied. Although pneumococcal vaccine had similar coverage at 12 months to other vaccines, coverage was lower for rotavirus at 12 months (83.6%) and varicella at 24 months (84.4%). Although 'fully vaccinated' coverage at 12 months of age was lower among Indigenous children than non-Indigenous children in all jurisdictions, the extent of the difference varied, reaching a 15 percentage point differential in South Australia but only a 0.4 percentage point differential in the Northern Territory. Overall, Indigenous coverage at 24 months of age exceeded that at 12 months of age nationally and for all jurisdictions, but as receipt of varicella vaccine at 18 months is excluded from calculations, this represents delayed immunisation, with some contribution from immunisation incentives. The 'fully vaccinated' coverage estimates for vaccinations due by 60 months of age for Indigenous children exceeded 90% at 91% in 2012. Unlike in 2011, at 60 months of age, there was no dramatic variation in coverage between Indigenous and non-Indigenous children for individual jurisdictions. As previously documented, vaccines recommended for Indigenous children only, hepatitis A and pneumococcal vaccine, had suboptimal coverage at 60.1% and 73.1%, respectively, although there was a considerable improvement in coverage from 2011, 57.7% and 68.2% respectively. On-time receipt (before 49 months of age) of vaccines by Indigenous children at the 60-month milestone age improved substantially between 2011 (19%) and 2012 (38%) but the disparity in on-time vaccination between Indigenous and non-Indigenous children worsened at the 60-month age milestone from 2011 (from 1.8 to 5.4 percentage points) and remained the same for the 12 and 24-month age milestones. By late 2012, the percentage of children who received the 1st dose of DTPa vaccine dose at less than 8 weeks of age was greater than 50% in all but 1 jurisdiction and greater than 70% for New South Wales, the Australian Capital Territory and Tasmania. Further, by late 2012, the percentage of children who received the 4th dose of DTPa vaccine dose at less than 4 years of age was greater than 30% in 3 jurisdictions. The percentage of children whose parents officially objected to vaccination in Australia was 1.7% and this figure varied by jurisdiction. However, there is a further 2.1% of children whose parents don't officially object but whose children have no vaccines recorded on the ACIR. Coverage data for the 3rd dose of HPV from the national HPV register in the school catch up program was similar to 2011 at 71% but was substantially lower for the catch up program for females outside school (44%-69%), although this was an improvement from 2011.
Mugo, Peter Mwangi; Sanders, Eduard J; Mutua, Gaudensia; van der Elst, Elisabeth; Anzala, Omu; Barin, Burc; Bangsberg, David R; Priddy, Frances H; Haberer, Jessica E
2015-05-01
A qualitative assessment of Kenyan men who have sex with men taking daily and intermittent oral HIV pre-exposure prophylaxis (PrEP) found stigma, sex work, mobility, and alcohol impacted adherence. We analyzed quantitative data from the same cohort to explore different definitions of intermittent adherence. Volunteers were randomized to daily emtricitabine/tenofovir or placebo, or intermittent (prescription: Mondays/Fridays/after sex, maximum 1 dose/day) emtricitabine/tenofovir or placebo (2:1:2:1), and followed for 4 months. By electronic monitoring, median adherence for daily dosing was 80 %. Median adherence for intermittent dosing was 71 % per a "relaxed" definition (accounting for off-prescription dosing) and 40 % per a "strict" definition (limited to the prescription). Factors associated with lower adherence included travel, transactional sex, and longer follow-up; higher adherence was associated with daily dosing and an income. The definition of intermittent dosing strongly affects interpretation of adherence. These findings suggest interventions should address challenges of mobility, sex work, and long-term PrEP.
Mutua, Gaudensia; Sanders, Eduard; Mugo, Peter; Anzala, Omu; Haberer, Jessica E; Bangsberg, David; Barin, Burc; Rooney, James F; Mark, David; Chetty, Paramesh; Fast, Patricia; Priddy, Frances H
2012-01-01
Little is known about safety of and adherence to intermittent HIV PrEP regimens, which may be more feasible than daily dosing in some settings. We present safety and adherence data from the first trial of an intermittent PrEP regimen among Kenyan men who have sex with men (MSM) and female sex workers (FSW). MSM and FSW were randomized to daily oral FTC/TDF or placebo, or intermittent (Monday, Friday and within 2 hours after sex, not to exceed one dose per day) oral FTC/TDF or placebo in a 2:1:2:1 ratio; volunteers were followed monthly for 4 months. Adherence was assessed with the medication event monitoring system (MEMS). Sexual activity data were collected via daily text message (SMS) queries and timeline followback interviews with a one-month recall period. Sixty-seven men and 5 women were randomized into the study. Safety was similar among all groups. Median MEMS adherence rates were 83% [IQR: 63-92] for daily dosing and 55% [IQR:28-78] for fixed intermittent dosing (p = 0.003), while adherence to any post-coital doses was 26% [IQR:14-50]. SMS response rates were low, which may have impaired measurement of post-coital dosing adherence. Acceptability of PrEP was high, regardless of dosing regimen. Adherence to intermittent dosing regimens, fixed doses, and in particular coitally-dependent doses, may be more difficult than adherence to daily dosing. However, intermittent dosing may still be appropriate for PrEP if intracellular drug levels, which correlate with prevention of HIV acquisition, can be attained with less than daily dosing and if barriers to adherence can be addressed. Additional drug level data, qualitative data on adherence barriers, and better methods to measure sexual activity are necessary to determine whether adherence to post-coital PrEP could be comparable to more standard regimens. ClinicalTrials.gov NCT00971230.
NSW Annual Immunisation Coverage Report, 2009.
Hull, Brynley; Dey, Aditi; Mahajan, Deepika; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B
2010-01-01
This is the first in a series of annual immunisation coverage reports that document trends in NSW for a range of standard measures derived from Australian Childhood Immunisation Register data, including overall coverage at standard age milestones and for individual vaccines. This report includes data up to and including 2009. Data from the Australian Childhood Immunisation Register, the NSW Health Survey and the NSW School Immunisation Program were used to calculate various measures of population coverage relating to childhood vaccines, adult influenza and pneumococcal vaccines and adolescent vaccination, respectively. Immunise Australia Program targets have been reached for children at 12 and 24 months of age but not for children at 5 years of age. Delayed receipt of vaccines is an issue for vaccines recommended for Aboriginal children. Pneumococcal vaccination in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. For adolescents, there is better coverage for the first and second doses of human papillomavirus vaccine and the dose of dTpa than for varicella. This comprehensive analysis provides important baseline data for NSW against which future reports can be compared to monitor progress in improving immunisation coverage. Immunisation at the earliest appropriate age should be a public health goal for countries such as Australia where high levels of vaccine coverage at milestone ages have been achieved.
NASA Astrophysics Data System (ADS)
Lindfors, A. V.; Arola, A.; Kaurola, J.; Taalas, P.; Svenøe, T.
2003-04-01
A method for estimating daily erythemal UV doses using total ozone, sunshine duration and snow depth has been developed. The method consists of three steps: (1) daily clear-sky UV doses were simulated using the UVSPEC radiative transfer program, with daily values of total ozone as input data, (2) an empirical relationship was sought between the simulated clear-sky UV doses, the measured UV doses and the duration of bright sunshine, (3) daily erythemal UV doses were estimated using this relationship. The method accounts for the varying surface albedo by dividing the period of interest into winter and summer days, depending on the snow depth. Using this method, the daily erythemal UV doses at Sodankylä were estimated for the period 1950--99. This was done using Tromsø's total ozone together with Sodankylä's own sunshine duration and snow depth as input data. Although the method is fairly simple, the results are in good agreement, even on the daily scale, with the UV radiation measured with the Brewer spectrophotometer at Sodankylä. Statistically significant increasing trends in erythemal UV doses of a few percents per decade over the period 1950--99 were found for March and April, suggesting a connection to the stratospheric ozone depletion. For July, on the other hand, a significant decreasing trend of about 3% per decade, supported by the changes in both total ozone and sunshine duration, was found. The produced data set of erythemal UV doses is the longest time series of estimated UV known to the authors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Lilie L., E-mail: lin@xrt.upenn.edu; Kirk, Maura; Scholey, Jessica
2016-05-01
Purpose: To report the acute toxicities associated with pencil beam scanning proton beam radiation therapy (PBS) for whole pelvis radiation therapy in women with gynecologic cancers and the results of a dosimetric comparison of PBS versus intensity modulated radiation therapy (IMRT) plans. Methods and Materials: Eleven patients with posthysterectomy gynecologic cancer received PBS to the whole pelvis. The patients received a dose of 45 to 50.4 Gy relative biological effectiveness (RBE) in 1.8 Gy (RBE) daily fractions. Acute toxicity was scored according to the Common Terminology Criteria for Adverse Events, version 4. A dosimetric comparison between a 2-field posterior oblique beam PBSmore » and an IMRT plan was conducted. The Wilcoxon signed rank test was used to assess the potential dosimetric differences between the 2 plans and PBS target coverage robustness relative to setup uncertainties. Results: The median patient age was 55 years (range 23-76). The primary site was cervical in 7, vaginal in 1, and endometrial in 3. Of the 11 patients, 7 received concurrent cisplatin, 1 each received sandwich carboplatin and paclitaxel chemotherapy, both sandwich and concurrent chemotherapy, and concurrent and adjuvant chemotherapy, and 1 received no chemotherapy. All patients completed treatment. Of the 9 patients who received concurrent chemotherapy, the rate of grade 2 and 3 hematologic toxicities was 33% and 11%, respectively. One patient (9%) developed grade 3 acute gastrointestinal toxicity; no patient developed grade ≥3 genitourinary toxicity. The volume of pelvic bone marrow, bladder, and small bowel receiving 10 to 30 Gy was significantly lower with PBS than with intensity modulated radiation therapy (P<.001). The target coverage for all PBS plans was robust relative to the setup uncertainties (P>.05) with the clinical target volume mean dose percentage received by 95% and 98% of the target volume coverage changes within 2% for the individual plans. Conclusions: Our results have demonstrated the clinical feasibility of PBS and the dosimetric advantages, especially for the low-dose sparing of normal tissues in the pelvis with the target robustness maintained relative to the setup uncertainties. Future studies with larger patient numbers are planned to further validate our preliminary findings.« less
Gugsa, Frey; Karmarkar, Ellora; Cheyne, Andrew; Yamey, Gavin
2016-01-13
To examine newspaper coverage of maternal health in three countries that have made varying progress towards Millennium Development Goal 5 (MDG 5): Bangladesh (on track), Rwanda (making progress, but not on track) and South Africa (no progress). We analysed each country's leading national English-language newspaper: Bangladesh's The Daily Star, Rwanda's The New Times/The Sunday Times, and South Africa's Sunday Times/The Times. We quantified the number of maternal health articles published from 1 January 2008 to 31 March 2013. We conducted a content analysis of subset of 190 articles published from 1 October 2010 to 31 March 2013. Bangladesh's The Daily Star published 579 articles related to maternal health from 1 January 2008 to 31 March 2013, compared to 342 in Rwanda's The New Times/The Sunday Times and 253 in South Africa's Sunday Times/The Times over the same time period. The Daily Star had the highest proportion of stories advocating for or raising awareness of maternal health. Most maternal health articles in The Daily Star (83%) and The New Times/The Sunday Times (69%) used a 'human-rights' or 'policy-based' frame compared to 41% of articles from Sunday Times/The Times. In the three countries included in this study, which are on different trajectories towards MDG 5, there were differences in the frequency, tone and content of their newspaper coverage of maternal health. However, no causal conclusions can be drawn about this association between progress on MDG 5 and the amount and type of media coverage of maternal health. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Action spectrum for phototherapy of psoriasis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parrish, J.A.; Jaenicke, K.F.
1981-05-01
Using a monochromator the action spectrum for ultraviolet phototherapy of psoriasis was determined for radiation between 254 and 313 nm and compared to the action spectrum for erythema of uninvolved adjacent skin. Daily exposures of different doses of 254, 280, 290, 296, 300, 304 and 313 nm radiation were observed. Wavelengths of 254, 280, 290 nm were erythemogenic but not therapeutic even at 10 to 50 times the minimal erythema dose. At the other wavelengths studied, the 2 action spectra were similar. In general, fixed daily doses cleared at lower cumulative dose than did incrementally increased daily doses. The smallmore » number of suberythemogenic exposure doses required suggests that monochromatic radiation may have advantages over broadband sources.« less
Kinoshita, Yoshikazu; Hongo, Michio; Kusano, Motoyasu; Furuhata, Yoshinori; Miyagishi, Hideaki; Ikeuchi, Satoshi
2017-01-01
Objective To investigate the effect of twice-daily rabeprazole doses on health-related quality of life in refractory patients. Methods and Patients Reflux esophagitis patients with an insufficient response to once-daily proton pump inhibitor therapy (Los Angeles Classification grade A-D) received rabeprazole 10 mg or 20 mg twice daily for 8 weeks. The health-related quality of life (SF-8™) and symptoms, using the Frequency Scale for the Symptoms of Gastroesophageal reflux disease, were evaluated before treatment and at weeks 4 and 8. Endoscopy was performed at baseline and at weeks 8 and 32 where possible. The rabeprazole dose was determined by the attending physician. Results There were 1,796 patients analyzed for the efficacy of the twice-daily treatment. Of these cases, 1,462 were treated with rabeprazole 10 mg twice daily, and 334 were treated with rabeprazole 20 mg twice daily. The factors that affected the selection of the twice-daily rabeprazole dose by physicians were evaluated, and as expected, “endoscopic findings when treatment was started” had a strong effect on the selection of the rabeprazole dose. With both regimens, health-related quality of life and subjective symptoms were significantly improved at weeks 4 and 8 compared to baseline (p<0.001). The recurrence rate of erosive esophagitis at week 32 was 9.7% in rabeprazole twice daily-treated patients and 28.4% in proton pump inhibitor (PPI) once daily-treated patients. Both regimens were well tolerated. Conclusion Twice-daily treatment with rabeprazole improved the subjective symptoms and health-related quality of life in patients with refractory reflux esophagitis more effectively than the standard once-daily dose. PMID:28502925
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bosarge, Christina L., E-mail: cbosarge@umail.iu.edu; Ewing, Marvene M.; DesRosiers, Colleen M.
To demonstrate the dosimetric advantages and disadvantages of standard anteroposterior-posteroanterior (S-AP/PA{sub AAA}), inverse-planned AP/PA (IP-AP/PA) and volumetry-modulated arc (VMAT) radiotherapies in the treatment of children undergoing whole-lung irradiation. Each technique was evaluated by means of target coverage and normal tissue sparing, including data regarding low doses. A historical approach with and without tissue heterogeneity corrections is also demonstrated. Computed tomography (CT) scans of 10 children scanned from the neck to the reproductive organs were used. For each scan, 6 plans were created: (1) S-AP/PA{sub AAA} using the anisotropic analytical algorithm (AAA), (2) IP-AP/PA, (3) VMAT, (4) S-AP/PA{sub NONE} without heterogeneitymore » corrections, (5) S-AP/PA{sub PB} using the Pencil-Beam algorithm and enforcing monitor units from technique 4, and (6) S-AP/PA{sub AAA[FM]} using AAA and forcing fixed monitor units. The first 3 plans compare modern methods and were evaluated based on target coverage and normal tissue sparing. Body maximum and lower body doses (50% and 30%) were also analyzed. Plans 4 to 6 provide a historic view on the progression of heterogeneity algorithms and elucidate what was actually delivered in the past. Averages of each comparison parameter were calculated for all techniques. The S-AP/PA{sub AAA} technique resulted in superior target coverage but had the highest maximum dose to every normal tissue structure. The IP-AP/PA technique provided the lowest dose to the esophagus, stomach, and lower body doses. VMAT excelled at body maximum dose and maximum doses to the heart, spine, and spleen, but resulted in the highest dose in the 30% body range. It was, however, superior to the S-AP/PA{sub AAA} approach in the 50% range. Each approach has strengths and weaknesses thus associated. Techniques may be selected on a case-by-case basis and by physician preference of target coverage vs normal tissue sparing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, L; Fan, J; Eldib, A
Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-housemore » developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.« less
Moodley, Dhayendre; Reddy, Leanne; Mahungo, Wisani; Masha, Rebotile
2013-01-01
The World Health Organisation and the Joint United Nations Programme in 2006 reaffirmed the earlier recommendation of 2000 that all HIV-exposed infants in resource-poor countries should commence cotrimoxazole (CTX) prophylaxis at 6-weeks of life. CTX prophylaxis should be continued until the child is confirmed HIV-uninfected and there is no further exposure to breastmilk transmission. We determined CTX coverage and explored factors associated with CTX administration in HIV-exposed infants at a primary health clinic in South Africa. In a cross-sectional study of HIV-exposed infants 6-18 months of age attending a child immunisation clinic, data from the current visit and previous visits related to CTX prophylaxis, feeding practice and infant HIV testing were extracted from the child's immunisation record. Further information related to the administration of CTX prophylaxis was obtained from an interview with the child's mother. One-third (33.0%) HIV-exposed infants had not initiated CTX at all and breastfed infants were more likely to have commenced CTX prophylaxis as compared to their non-breastfed counterparts (78.7% vs 63.4%) (p = 0.008). Availability of infant's HIV status was strongly associated with continuation or discontinuation of CTX after 6 months of age or after breastfeeding cessation. Maternal self-reports indicated that only 52.5% (95%CI 47.5-57.5) understood the reason for CTX prophylaxis, 126 (47%) did not dose during weekends; 55 (21%) dosed their infants 3 times a day and 70 (26%) dosed their infants twice daily. A third of HIV-exposed children attending a primary health care facility in this South African setting did not receive CTX prophylaxis. Not commencing CTX prophylaxis was strongly associated with infants not breastfeeding and unnecessary continued exposure to CTX in this paediatric population was due to limited availability of early infant diagnosis. Attendance at immunization clinics can be seen as missed opportunities for early infant diagnosis of HIV and related care.
Moodley, Dhayendre; Reddy, Leanne; Mahungo, Wisani; Masha, Rebotile
2013-01-01
Background The World Health Organisation and the Joint United Nations Programme in 2006 reaffirmed the earlier recommendation of 2000 that all HIV-exposed infants in resource-poor countries should commence cotrimoxazole (CTX) prophylaxis at 6-weeks of life. CTX prophylaxis should be continued until the child is confirmed HIV-uninfected and there is no further exposure to breastmilk transmission. We determined CTX coverage and explored factors associated with CTX administration in HIV-exposed infants at a primary health clinic in South Africa. Methods In a cross-sectional study of HIV-exposed infants 6–18 months of age attending a child immunisation clinic, data from the current visit and previous visits related to CTX prophylaxis, feeding practice and infant HIV testing were extracted from the child's immunisation record. Further information related to the administration of CTX prophylaxis was obtained from an interview with the child's mother. Results One-third (33.0%) HIV-exposed infants had not initiated CTX at all and breastfed infants were more likely to have commenced CTX prophylaxis as compared to their non-breastfed counterparts (78.7% vs 63.4%) (p = 0.008). Availability of infant's HIV status was strongly associated with continuation or discontinuation of CTX after 6 months of age or after breastfeeding cessation. Maternal self-reports indicated that only 52.5% (95%CI 47.5–57.5) understood the reason for CTX prophylaxis, 126 (47%) did not dose during weekends; 55 (21%) dosed their infants 3 times a day and 70 (26%) dosed their infants twice daily. Conclusion A third of HIV-exposed children attending a primary health care facility in this South African setting did not receive CTX prophylaxis. Not commencing CTX prophylaxis was strongly associated with infants not breastfeeding and unnecessary continued exposure to CTX in this paediatric population was due to limited availability of early infant diagnosis. Attendance at immunization clinics can be seen as missed opportunities for early infant diagnosis of HIV and related care. PMID:23667599
Helical tomotherapy in patients with breast cancer and complex treatment volumes.
Cendales, Ricardo; Schiappacasse, Luis; Schnitman, Franco; García, Graciela; Marsiglia, Hugo
2011-04-01
To describe early clinical results of tomotherapy treatment in patients with breast cancer and complex treatment volumes. Ten patients were treated with tomotherapy between January 2009 and March 2010. Treatment planning objectives were to cover at least 95% of the planning target volume with the 95% isodose; to have a minimum dose of 90% and a maximum dose of 105%. All treatments included daily CT/megavoltage image guidance. Acute toxicity was recorded weekly. Six patients were treated because constraints were not accomplished for heart, lung or contralateral breast in a previous three-dimensional conformal plan; two for preexisting cardiac or pulmonary disease, and two more for bilateral breast irradiation. Treatment volumes included the whole breast in the majority of patients, as well as the supraclavicular and the internal mammary chain nodes when indicated. Most patients were older than 50 years, and had an early breast cancer, with positive oestrogen receptors, negative HER2 expression and a poorly differentiated, infiltrating ductal carcinoma. The majority of patients had received neoadjuvant chemotherapy associated to breast-conserving surgery and adjuvant hormonotherapy. Median homogeneity index was 1.09; median coverage index was 0.81. Median V20Gy and V10Gy for ipsilateral lung was 20% and 37.1% respectively. Median V25 and V35 for heart was 15% and 4% respectively. Median dose for contralateral breast was 7 Gy. Skin acute toxicity was grade 1 in 41.7% and grade 2 in 58.3%. Tomotherapy is a technique capable of delivering a well tolerated treatment with high homogeneity and coverage indexes and high capabilities for sparing the organs at risk in patients with anatomically complex breast cancer, bilateral breast cancer, indication for internal mammary chain node irradiation, cardiac toxicity derived from chemotherapy, or preexisting cardiac or pulmonary disease. Further studies are required to evaluate local control and late toxicity.
Analyzing U.S. prescription lists with RxNorm and the ATC/DDD Index.
Bodenreider, Olivier; Rodriguez, Laritza M
2014-01-01
To evaluate the suitability of the ATC/DDD Index (Anatomical Therapeutic Chemical (ATC) Classification System/Defined Daily Dose) for analyzing prescription lists in the U.S. We mapped RxNorm clinical drugs to ATC. We used this mapping to classify a large set of prescription drugs with ATC and compared the prescribed daily dose to the defined daily dose (DDD) in ATC. 64% of the 11,422 clinical drugs could be precisely mapped to ATC. 97% of the 87,001 RxNorm codes from the prescription dataset could be classified with ATC, and 97% of the prescribed daily doses could be assessed. Although the mapping of RxNorm ingredients to ATC appears to be largely incomplete, the most frequently prescribed drugs in the prescription dataset we analyzed were covered. This study demonstrates the feasibility of using ATC in conjunction with RxNorm for analyzing U.S. prescription datasets for drug classification and assessment of the prescribed daily doses.
NASA Astrophysics Data System (ADS)
Malinovic-Milicevic, S.; Mihailovic, D. T.; Radovanovic, M. M.
2015-07-01
This paper focuses on the development and application of a technique for filling the daily erythemal UV dose data gaps and the reconstruction of the past daily erythemal UV doses in Novi Sad, Serbia. The technique implies developing the empirical equation for estimation of daily erythemal UV doses by means of relative daily sunshine duration under all sky conditions. A good agreement was found between modeled and measured values of erythemal UV doses. This technique was used for filling the short gaps in the erythemal UV dose measurement series (2003-2009) as well as for the reconstruction of the past time-series values (1981-2002). Statistically significant positive erythemal UV dose trend of 6.9 J m-2 per year was found during the period 1981-2009. In relation to the reference period 1981-1989, an increase in the erythemal UV dose of 6.92 % is visible in the period 1990-1999 and the increase of 9.67 % can be seen in the period 2000-2009. The strongest increase in erythemal UV doses has been found for winter and spring seasons.
USDA-ARS?s Scientific Manuscript database
Agricultural research increasingly is expected to provide precise, quantitative information with an explicit geographic coverage. Limited availability of continuous daily meteorological records often constrains efforts to provide such information through integrated use of simulation models, spatial ...
Vogel, J; Lin, L; Litzky, L A; Berman, A T; Simone, C B
2017-10-01
Thymic malignancies are the most common tumors of the anterior mediastinum. The benefit of adjuvant radiation therapy for stage II disease remains controversial, and patients treated with adjuvant radiation therapy are at risk of late complications, including radiation-induced secondary malignant neoplasms (SMNs), that may reduce the overall benefit of treatment. We assess the risk of predicted SMNs following adjuvant proton radiation therapy compared with photon radiation therapy after resection of stage II thymic malignancies to determine whether proton therapy improves the risk-benefit ratio. Ten consecutive patients treated with double-scattered proton beam radiation therapy (DS-PBT) were prospectively enrolled in an institutional review board-approved proton registry study. All patients were treated with DS-PBT. Intensity modulated radiation therapy (IMRT) plans for comparison were generated. SMN risk was calculated based on organ equivalent dose. Patients had a median age of 65 years (range, 25-77 years), and 60% were men. All patients had stage II disease, and many had close or positive margins (60%). The median dose was 50.4 Gy (range, 50.4-54.0 Gy) in 1.8-Gy relative biological effectiveness daily fractions. No differences in target coverage were seen with DS-PBT compared with IMRT plans. Significant reductions were seen in mean and volumetric lung, heart, and esophageal doses with DS-PBT compared with IMRT plans (all P≤.01). Significant reductions in SMNs in the lung, breast, esophagus, skin, and stomach were seen with DS-PBT compared with IMRT. For patients with thymoma diagnosed at the median national age, 5 excess secondary malignancies per 100 patients would be avoided by treating them with protons instead of photons. Treatment with proton therapy can achieve comparable target coverage but significantly reduced doses to critical normal structures, which can lead to fewer predicted SMNs compared with IMRT. By decreasing expected late complications, proton therapy may improve the therapeutic ratio of adjuvant radiation therapy for patients with stage II thymic malignancies. Copyright © 2017 Elsevier Inc. All rights reserved.
Efficacy of alternate day versus daily dosing of rosuvastatin
Dulay, Daisy; LaHaye, Stephen A; Lahey, Karen A; Day, Andrew G
2009-01-01
BACKGROUND: Compared with other statins, rosuvastatin has a relatively long half-life, which may allow for the administration of this medication on an alternate day basis. OBJECTIVE: To compare the efficacy of administering rosuvastatin on a daily basis versus on an alternate day basis for the treatment of dyslipidemia. METHODS: In the present crossover study, 45 patients with documented hypercholesterolemia requiring pharmacotherapy were administered either 20 mg of rosuvastatin on alternate days or 10 mg of rosuvastatin daily for six weeks. After a four-week washout period, patients were then switched to the other regimen for another six weeks. The primary end point was the percentage reduction of low-density lipoprotein cholesterol (LDL-C). RESULTS: LDL-C decreased by 48.5% versus 40.9% with daily and alternate day dosing, respectively. This represented an additional absolute reduction of LDL-C of 7.6% (95% CI 1.8% to 13.4%, P=0.012) with the daily dosing regimen. Both dosing regimens provided similar improvements in high-density lipoprotein cholesterol and triglycerides. CONCLUSIONS: Compared with alternate day dosing, daily dosing of rosuvastatin provides a statistically significant advantage in LDL-C reduction. However, the alternate day regimen may be a viable option for those patients in whom cost is a limitation to compliance. PMID:19214297
de Velde, Femke; de Winter, Brenda C M; Koch, Birgit C P; van Gelder, Teun; Mouton, Johan W
2016-10-01
To describe the population pharmacokinetics of oral amoxicillin and to compare the PTA of current dosing regimens. Two groups, each with 14 healthy male volunteers, received oral amoxicillin/clavulanic acid tablets on two separate days 1 week apart. One group received 875/125 mg twice daily and 500/125 mg three times daily and the other group 500/125 mg twice daily and 250/125 mg three times daily. A total of 1428 amoxicillin blood samples were collected before and after administration. We analysed the concentration-time profiles using a non-compartmental pharmacokinetic method (PKSolver) and a population pharmacokinetic method (NONMEM). The PTA was computed using Monte Carlo simulations for several dosing regimens. AUC0-24 and Cmax increased non-linearly with dose. The final model included the following components: Savic's transit compartment model, Michaelis-Menten absorption, two distribution compartments and first-order elimination. The mean central volume of distribution was 27.7 L and mean clearance was 21.3 L/h. We included variability for the central volume of distribution (34.4%), clearance (25.8%), transit compartment model parameters and Michaelis-Menten absorption parameters. For 40% fT>MIC and >97.5% PTA, the breakpoints were 0.125 mg/L (500 mg twice daily), 0.25 mg/L (250 mg three times daily and 875 mg twice daily), 0.5 mg/L (500 mg three times daily) and 1 mg/L (750, 875 or 1000 mg three times daily and 500 mg four times daily). The amoxicillin absorption rate appears to be saturable. The PTAs of high-dose as well as twice-daily regimens are less favourable than regimens with lower doses and higher frequency. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Bunupuradah, Torsak; Punyahotra, Passorn; Cressey, Tim R; Srimuan, Amornrat; Thammajaruk, Narukjaporn; Sophonphan, Jiratchaya; Sriheara, Chulalak; Burger, David M; Puthanakit, Thanyawee; Ananworanich, Jintanat
2015-07-01
Abacavir and lamivudine are approved for once-daily use in HIV-infected adults. Limited pharmacokinetic (PK) data for abacavir and lamivudine in children are available. A crossover study to compare PK of once- versus twice-daily abacavir and lamivudine was conducted in virologically suppressed HIV-infected Thai children aged <18years, with bodyweight of at least 14 kg, HIV RNA <50 copies/mL and HLA-B*5701 negative. Abacavir and lamivudine daily doses by bodyweight were 300 and 150 mg for 14-<20 kg, 450 and 300 mg for 20-<25 kg, and 600 and 300 mg for ≥25 kg, respectively. Originator abacavir and lamivudine scored tablets were administered. Intensive PK sampling was performed after 14 days of each dose. PK parameters were determined using non-compartmental analysis. Thirty children (57% male) were enrolled, 10 per weight band. Median (IQR) age was 8.8 (6.6-11.3) years and bodyweight was 21.9 (19.2-30.6) kg. The geometric means (GM) AUC0-24 of once- and twice-daily abacavir were 14.43 and 10.65 mg.h/L, respectively. The geometric mean ratio (GMR) of AUC0-24 for once- versus twice-daily abacavir dosing was 1.36 [90% confidence interval (CI) 1.11-1.66]. The GM AUC0-24 of once- and twice-daily lamivudine were 17.70 and 18.11 mg.h/L, respectively. The GMR of AUC0-24 for once- versus twice-daily lamivudine dosing was 0.98 (90% CI 0.84-1.14). At 96 weeks, 90% had HIV RNA <50 copies/mL and there were no serious adverse events. Abacavir exposure was greater with once-daily dosing, while lamivudine once- and twice-daily exposures were bioequivalent. Once-daily abacavir and lamivudine using weight-band dosing is a treatment option for children.
Bethel, M A; Harrison, P; Sourij, H; Sun, Y; Tucker, L; Kennedy, I; White, S; Hill, L; Oulhaj, A; Coleman, R L; Holman, R R
2016-02-01
Reduced aspirin efficacy has been demonstrated in people with Type 2 diabetes. Because increased platelet reactivity and/or turnover are postulated mechanisms, we examined whether higher and/or more frequent aspirin dosing might reduce platelet reactivity more effectively. Participants with Type 2 diabetes (n = 24) but without known cardiovascular disease were randomized in a three-way crossover design to 2-week treatment periods with aspirin 100 mg once daily, 200 mg once daily or 100 mg twice daily. The primary outcome was platelet reactivity, assessed using the VerifyNow(™) ASA method. Relationships between platelet reactivity and aspirin dosing were examined using generalized linear mixed models with random subject effects. Platelet reactivity decreased from baseline with all doses of aspirin. Modelled platelet reactivity was more effectively reduced with aspirin 100 mg twice daily vs. 100 mg once daily, but not vs. 200 mg once daily. Aspirin 200 mg once daily did not differ from 100 mg once daily. Aspirin 100 mg twice daily was also more effective than once daily as measured by collagen/epinephrine-stimulated platelet aggregation and urinary thromboxane levels, with a similar trend measured by serum thromboxane levels. No episodes of bleeding occurred. In Type 2 diabetes, aspirin 100 mg twice daily reduced platelet reactivity more effectively than 100 mg once daily, and numerically more than 200 mg once daily. Clinical outcome trials evaluating primary cardiovascular disease prevention with aspirin in Type 2 diabetes may need to consider using a more frequent dosing schedule. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.
Media Agendas and Human Rights: The Supreme Court Decision on Abortion.
ERIC Educational Resources Information Center
Pollock, John Crothers; And Others
1978-01-01
Examines coverage of the abortion issue prior to, during, and after the 1973 Supreme Court decision legalizing elective abortion in daily newspapers in Boston, Chicago, Los Angeles, New York, and Washington, D.C. Considers the effect on news coverage of local religious composition, income levels, race, and abortion rate. (GW)
Hispanic Americans in the News in Two Southwestern Cities.
ERIC Educational Resources Information Center
Turk, Judy VanSlyke; And Others
1989-01-01
Examines how Hispanic Americans and Hispanic issues were covered by daily newspapers in New Mexico and Texas, two states where complaints relating to media coverage were investigated by state human rights commissions. Reports that Hispanics appear to be receiving ample and fair coverage in San Antonio, Texas, and Albuquerque, New Mexico. (MM)
Kids, Crime, and Local Television News
ERIC Educational Resources Information Center
Yanich, Danilo
2005-01-01
The vast majority of crime reporting occurs on local television news and in newspapers. Although crimes are extraordinary events, they assume an ordinariness that only daily reporting can give them. The obvious question is what does the news tell us about crime. This article compares the coverage of adult crime and the coverage of what the author…
Newspaper Coverage of the Harvard Medicare Project: Regional Distinctions/Discreet Disregard?
ERIC Educational Resources Information Center
Payne, J. Gregory
A study examined American newspaper coverage of the Harvard Medicare Project proposal of 1986, a major health policy proposal calling for comprehensive reforms in the national health program. Using Burrelle's news clipping service which includes every daily newspaper (over 1500) in the United States, all 75 newspaper articles on the project from…
Patient-specific dose estimation for pediatric abdomen-pelvis CT
NASA Astrophysics Data System (ADS)
Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.
2009-02-01
The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.
Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Zhang, Jun; Dutta, Sandeep
2013-01-01
Aim The objective of this work was to characterize the safety, tolerability and pharmacokinetics of ABT-288, a highly selective histamine H3 receptor antagonist, in healthy young adults and elderly subjects following single and multiple dosing in a phase 1 setting. Methods Single doses (0.1, 0.3, 1, 3, 10, 20 and 40 mg ABT-288) and multiple doses (0.5, 1.5, 3 and 6 mg ABT-288 once-daily for 14 days) were evaluated in young adults and multiple doses (0.5, 1.5, 3 and 5 mg ABT-288 once-daily for 12 days) were evaluated in elderly subjects using randomized, double-blind, placebo-controlled, dose-escalating study designs. The effect of food on ABT-288 pharmacokinetics (5 mg single dose) was evaluated using an open label, randomized, crossover design. Results ABT-288 safety, tolerability and pharmacokinetics were comparable in young and elderly subjects. Single doses up to 40 mg and multiple doses up to 3 mg once-daily were generally safe and well tolerated. The most frequently reported adverse events were hot flush, headache, abnormal dreams, insomnia, nausea and dizziness. ABT-288 exposure (AUC) was dose-proportional over the evaluated dose ranges. The mean elimination half-life ranged from 40 to 61 h across dose groups. Steady state was achieved by day 10 of once-daily dosing with 3.4- to 4.2-fold accumulation. Food did not have a clinically meaningful effect on ABT-288 exposure. Conclusions Based on the above results, 1 and 3 mg once-daily doses of ABT-288 were advanced to phase 2 evaluation in Alzheimer's patients. PMID:23016924
Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Zhang, Jun; Dutta, Sandeep
2013-05-01
The objective of this work was to characterize the safety, tolerability and pharmacokinetics of ABT-288, a highly selective histamine H3 receptor antagonist, in healthy young adults and elderly subjects following single and multiple dosing in a phase 1 setting. Single doses (0.1, 0.3, 1, 3, 10, 20 and 40 mg ABT-288) and multiple doses (0.5, 1.5, 3 and 6 mg ABT-288 once-daily for 14 days) were evaluated in young adults and multiple doses (0.5, 1.5, 3 and 5 mg ABT-288 once-daily for 12 days) were evaluated in elderly subjects using randomized, double-blind, placebo-controlled, dose-escalating study designs. The effect of food on ABT-288 pharmacokinetics (5 mg single dose) was evaluated using an open label, randomized, crossover design. ABT-288 safety, tolerability and pharmacokinetics were comparable in young and elderly subjects. Single doses up to 40 mg and multiple doses up to 3 mg once-daily were generally safe and well tolerated. The most frequently reported adverse events were hot flush, headache, abnormal dreams, insomnia, nausea and dizziness. ABT-288 exposure (AUC) was dose-proportional over the evaluated dose ranges. The mean elimination half-life ranged from 40 to 61 h across dose groups. Steady state was achieved by day 10 of once-daily dosing with 3.4- to 4.2-fold accumulation. Food did not have a clinically meaningful effect on ABT-288 exposure. Based on the above results, 1 and 3 mg once-daily doses of ABT-288 were advanced to phase 2 evaluation in Alzheimer's patients. © 2012 Abbott Laboratories. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.
Issell, Brian F.; Gotay, Carolyn C.; Pagano, Ian; Franke, A. Adrian
2015-01-01
Purpose We conducted a Phase I study of noni in patients with advanced cancer. Quality of life measures were examined as an alternate way to select a Phase II dose of this popular dietary supplement. Patients and Methods Starting at two capsules twice daily (2 grams), the dose suggested for marketed products, dose levels were escalated by 2 grams daily in cohorts of at least five patients until a maximum tolerated dose was found. Patients completed QLQ-C30 Quality of Life, and the Brief Fatigue Inventory (BFI), questionnaires at baseline and at four week intervals. Scopoletin was measured in blood and urine collected at baseline and at approximately four week intervals. Results Fifty-one patients were enrolled at seven dose levels. Seven capsules four times daily (14 grams) was the maximum tolerated dose. No dose limiting toxicity was found but four of eight patients at this level withdrew from the study due to the challenges of ingesting so many capsules. There was a dose response for self reported physical functioning and the control of pain and fatigue. Patients taking four capsules four times daily experienced less fatigue than patients taking lower or higher doses. A relationship between noni dose and blood and urinary scopoletin concentrations was found. Conclusion Measuring quality of life to determine a dose for subsequent Phase II testing is feasible. A noni dose of four capsules four times daily (8 grams) is recommended for Phase II testing where controlling fatigue and maintaining physical function is the efficacy of interest. Scopoletin is a measurable noni ingredient for pharmacokinetic studies in patients with cancer. PMID:22435516
Fakih, Marwan G; Pendyala, Lakshmi; Fetterly, Gerald; Toth, Karoli; Zwiebel, James A; Espinoza-Delgado, Igor; Litwin, Alan; Rustum, Youcef M; Ross, Mary Ellen; Holleran, Julianne L; Egorin, Merrill J
2009-05-01
We conducted a phase I study to determine the maximum tolerated dose of vorinostat in combination with fixed doses of 5-fluorouracil (FU), leucovorin, and oxaliplatin (FOLFOX). Vorinostat was given orally twice daily for 1 week every 2 weeks. FOLFOX was given on days 4 and 5 of vorinostat. The vorinostat starting dose was 100 mg twice daily. Escalation occurred in cohorts of three to six patients. Pharmacokinetics of vorinostat, FU, and oxaliplatin were studied. Twenty-one patients were enrolled. Thrombocytopenia, neutropenia, gastrointestinal toxicities, and fatigue increased in frequency and severity at higher dose levels of vorinostat. Two of 4 evaluable patients at dose level 4 (vorinostat 400 mg orally twice daily) developed dose-limiting fatigue. One of 10 evaluable patients at dose level 3 (vorinostat 300 mg orally twice daily) had dose-limiting fatigue, anorexia, and dehydration. There were significant relationships between vorinostat dose and the area under the curve on days 1 and 5 (Pearson, < 0.001). The vorinostat area under the curve increased (P = 0.005) and clearance decreased (P = 0.003) on day 5 compared with day 1. The median C(max) of FU at each dose level increased significantly with increasing doses of vorinostat, suggesting a pharmacokinetic interaction between FU and vorinostat. Vorinostat-induced thymidylate synthase (TS) modulation was not consistent; only two of six patients had a decrease in intratumoral TS expression by reverse transcription-PCR. The maximum tolerated dose of vorinostat in combination with FOLFOX is 300 mg orally twice daily x 1 week every 2 weeks. Alternative vorinostat dosing schedules may be needed for optimal down-regulation of TS expression.
Dunbar, Lala M.; Milata, Joe; McClure, Ty; Wasilewski, Margaret M.
2011-01-01
Oritavancin is a novel lipoglycopeptide with demonstrated effectiveness against complicated skin and skin structure infections (cSSSI) caused by Gram-positive pathogens, including those caused by methicillin-resistant Staphylococcus aureus (MRSA). The pharmacokinetic and pharmacodynamic profile of oritavancin is favorable for single or infrequent dosing. A phase 2, multicenter, randomized, double-blind, parallel, active-comparator study (ClinicalTrials.gov identifier, NCT00514527) of single and infrequent dosing of intravenous (i.v.) oritavancin for the treatment of cSSSI caused by Gram-positive pathogens (wound infections, major abscess, and cellulitis) was undertaken to evaluate the noninferiority of front-loaded dosing regimens compared to a daily-dosing regimen. A total of 302 patients ≥18 years of age were randomized equally to one of three oritavancin treatment groups, receiving either a daily dose (200 mg) administered for 3 to 7 days, a single dose (1,200 mg), or an infrequent dose (800-mg dose, with the option for an additional 400 mg on day 5). The primary efficacy was defined as a clinical response in clinically evaluable (CE) patients assessed at days 21 to 29 (test of cure [TOC]). The cure rates in the CE population were 72.4% (55/76) in the daily-dose group, 81.5% (66/81) in the 1,200-mg-single-dose group, and 77.5% (55/71) in the infrequent-dose group. In patients with MRSA at baseline, the cure rates were 78.3% (18/23), 73.0% (27/37), and 87.0% (20/23) in the daily-, 1,200-mg-single-, and infrequent-dose groups, respectively; however, the study was not powered to assess outcomes in the MRSA subpopulation, and given the heterogeneity of the types of infection and the small sample size, these do not suggest any true differences in efficacy rates for these pathogens. The frequencies of adverse events were similar among treatment groups. The results of this study show that single- and infrequent-dosing schedules of oritavancin were as efficacious as daily administration and had a similar safety profile in treating cSSSI caused by Gram-positive pathogens, including MRSA. PMID:21537018
Determinants of vaccination coverage in rural Nigeria.
Odusanya, Olumuyiwa O; Alufohai, Ewan F; Meurice, Francois P; Ahonkhai, Vincent I
2008-11-05
Childhood immunization is a cost effective public health strategy. Expanded Programme on Immunisation (EPI) services have been provided in a rural Nigerian community (Sabongidda-Ora, Edo State) at no cost to the community since 1998 through a privately financed vaccination project (private public partnership). The objective of this survey was to assess vaccination coverage and its determinants in this rural community in Nigeria A cross-sectional survey was conducted in September 2006, which included the use of interviewer-administered questionnaire to assess knowledge of mothers of children aged 12-23 months and vaccination coverage. Survey participants were selected following the World Health Organization's (WHO) immunization coverage cluster survey design. Vaccination coverage was assessed by vaccination card and maternal history. A child was said to be fully immunized if he or she had received all of the following vaccines: a dose of Bacille Calmette Guerin (BCG), three doses of oral polio (OPV), three doses of diphtheria, pertussis and tetanus (DPT), three doses of hepatitis B (HB) and one dose of measles by the time he or she was enrolled in the survey, i.e. between the ages of 12-23 months. Knowledge of the mothers was graded as satisfactory if mothers had at least a score of 3 out of a maximum of 5 points. Logistic regression was performed to identify determinants of full immunization status. Three hundred and thirty-nine mothers and 339 children (each mother had one eligible child) were included in the survey. Most of the mothers (99.1%) had very positive attitudes to immunization and > 55% were generally knowledgeable about symptoms of vaccine preventable diseases except for difficulty in breathing (as symptom of diphtheria). Two hundred and ninety-five mothers (87.0%) had a satisfactory level of knowledge. Vaccination coverage against all the seven childhood vaccine preventable diseases was 61.9% although it was significantly higher (p = 0.002) amongst those who had a vaccination card (131/188, 69.7%) than in those assessed by maternal history (79/151, 52.3%). Multiple logistic regression showed that mothers' knowledge of immunization (p = 0.006) and vaccination at a privately funded health facility (p < 0.001) were significantly correlated with the rate of full immunization. Eight years after initiation of this privately financed vaccination project (private-public partnership), vaccination coverage in this rural community is at a level that provides high protection (81%) against DPT/OPV. Completeness of vaccination was significantly correlated with knowledge of mothers on immunization and adequate attention should be given to this if high coverage levels are to be sustained.
Stoffel, Nicole U; Cercamondi, Colin I; Brittenham, Gary; Zeder, Christophe; Geurts-Moespot, Anneke J; Swinkels, Dorine W; Moretti, Diego; Zimmermann, Michael B
2017-11-01
Current guidelines to treat iron deficiency recommend daily provision of ferrous iron divided through the day to increase absorption. However, daily dosing and split dosing might increase serum hepcidin and decrease iron absorption from subsequent doses. Our study aim was to compare iron absorption from oral iron supplements given on consecutive versus alternate days and given as single morning doses versus twice-daily split dosing. We did two prospective, open-label, randomised controlled trials assessing iron absorption using ( 54 Fe)-labelled, ( 57 Fe)-labelled, or ( 58 Fe)-labelled ferrous sulfate in iron-depleted (serum ferritin ≤25 μg/L) women aged 18-40 years recruited from ETH Zurich and the University of Zurich, Switzerland. In study 1, women were randomly assigned (1:1) to two groups. One group was given 60 mg iron at 0800 h (±1 h) on consecutive days for 14 days, and the other group was given the same doses on alternate days for 28 days. In study 2, women were assigned to two groups, stratified by serum ferritin so that two groups with similar iron statuses could be formed. One group was given 120 mg iron at 0800 h (±1 h) and the other was given the dose split into two divided doses of 60 mg at 0800 h (±1 h) and 1700 h (±1 h) for three consecutive days. 14 days after the final dose, the groups were each crossed over to the other regimen. Within-individual comparisons were done. The co-primary outcomes in both studies were iron bioavailability (total and fractional iron absorption), assessed by measuring the isotopic label abundance in erythrocytes 14 days after administration, and serum hepcidin. Group allocations in both studies were not masked and primary and safety analyses were done on an intention-to-treat basis. The studies were registered at ClinicalTrials.gov, numbers NCT02175888 (study 1) and NCT02177851 (study 2) and are complete. For study 1, 40 women were enrolled on Oct 15-29, 2015. 21 women were assigned to the consecutive-day group and 19 to the alternate-day group. At the end of treatment (14 days for the consecutive-day group and 28 days for the alternate-day group), geometric mean (-SD, +SD) cumulative fractional iron absorptions were 16·3% (9·3, 28·8) in the consecutive-day group versus 21·8% (13·7, 34·6) in the alternate-day group (p=0·0013), and cumulative total iron absorption was 131·0 mg (71·4, 240·5) versus 175·3 mg (110·3, 278·5; p=0·0010). During the first 14 days of supplementation in both groups, serum hepcidin was higher in the consecutive-day group than the alternate-day group (p=0·0031). In study 2, 20 women were enrolled between Aug 13 and 18, 2015. Ten women were assigned to receive once-daily dosing and ten were assigned to receive twice-daily divided dosing. No significant differences were seen in fractional (day 1-3 geometric mean: 11·8% [7·1, 19·4] once daily vs 13·1% [8·2, 20·7] twice daily; p=0·33) or total iron absorption (day 1-3: 44·3 mg [29·4, 66·7] once daily vs 49·4 [35·2, 69·4] twice daily; p=0·33) between the two dosing regimens. Twice-daily divided doses resulted in a higher serum hepcidin concentration than once-daily dosing (p=0·013). No grade 3 or 4 adverse events were reported in either study. In iron-depleted women, providing iron supplements daily as divided doses increases serum hepcidin and reduces iron absorption. Providing iron supplements on alternate days and in single doses optimises iron absorption and might be a preferable dosing regimen. These findings should be confirmed in iron-deficient anaemic patients. Swiss National Science Foundation, Bern, Switzerland. Copyright © 2017 Elsevier Ltd. All rights reserved.
[The stigmatising of schizophrenia and autism in the Flemish daily papers].
Thys, E; Struyven, C I; Danckaerts, M; De Hert, M
2014-01-01
A considerable social stigma is attached to many types of psychiatric disorders. However, research also shows that there are differences in the degree of social stigma attached to psychiatric disorders. There is evidence that the portrayal of schizophrenia in the media is particularly negative. To compare the degree of stigma in reporting of autism and schizophrenia in the Flemish daily newspapers. Via the websites of the seven Flemish daily newspapers, we searched for all articles published between 2008 and 2012 containing the keywords autism/autist(ic) and schizophrenia/schizophrenic. The collected articles (n = 4,181) were then graded to their stigmatising content. In the collected articles the coverage of autism was mostly positive, whereas the coverage of schizophrenia was predominantly negative. The contrast between the reporting on autism and on schizophrenia was very substantial (p < 0.0001) and the negative coverage of both disorders increased over time. The social stigma attached to schizophrenia is poignantly reflected in the Flemish newspapers. The fact that a disorder such as autism, which has many features in common with schizophrenia, is depicted in a much more favourable way than schizophrenia indicates that a more positive image of schizophrenia is not only desirable but also achievable.
Bittner, C J; Crawford, G I; Berger, L L; Holt, S; Pritchard, R R; Platter, W J; Van Koevering, M T; Pyatt, N A; Erickson, G E
2016-12-01
Three experiments evaluated the effects of ractopamine hydrochloride (RAC) dose and duration on growth performance and carcass characteristics of feedlot steers. In total, 1,509 crossbred steers (530 kg initial BW [SD 22]) were used in a randomized complete block design using a 3 × 3 factorial treatment structure. Treatments consisted of RAC dose (0, 100, or 200 mg/steer daily) and duration (28, 35, or 42 d) of RAC feeding prior to harvest. Initiation of RAC dose was staggered (7 d apart) based on RAC duration, which resulted in common days on feed among treatments. Data from the 3 experiments were combined for statistical analyses. There were no RAC dose × duration interactions ( ≥ 0.85) for growth performance. Live final BW was not different ( ≥ 0.24) as RAC dose increased. Dry matter intake linearly decreased ( < 0.01) as RAC dose increased. Live ADG and G:F linearly increased ( ≤ 0.01) as RAC dose increased. Carcass-adjusted ADG and G:F linearly increased ( ≤ 0.02) as RAC dose increased. Compared with steers fed 0 mg RAC/steer daily, G:F was improved by 5.0 and 13.0% when steers were fed 100 ( = 0.31) and 200 ( = 0.01) mg RAC/steer daily, respectively. Hot carcass weight tended ( = 0.10) to linearly increase as RAC dose increased, with carcasses from steers fed 100 ( = 0.38) and 200 ( = 0.10) mg RAC/steer daily being 2.2 and 4.1 kg heavier, respectively, than carcasses from steers fed 0 mg RAC/steer daily. Increasing RAC dose linearly ( < 0.01) increased LM area and linearly ( = 0.02) decreased marbling score. Live final BW was not different ( ≥ 0.60) among RAC durations. Carcass-adjusted final BW, ADG, and G:F were not different ( ≥ 0.41) as RAC duration increased. Carcass traits did not differ ( ≥ 0.18) among RAC duration. Feeding 200 mg RAC/steer daily improved ADG, feed efficiency, and HCW. Increasing the feeding duration of RAC had no effect of growth performance or carcass characteristics. These data indicate that feeding 200 mg RAC/steer daily for 28 d improves steer growth performance.
Flannery, Brendan; Samad, Samia; de Moraes, José Cássio; Tate, Jacqueline E.; Danovaro-Holliday, M. Carolina; de Oliveira, Lúcia Helena; Rainey, Jeanette J.
2015-01-01
Introduction In March, 2006, oral rotavirus vaccine was added to Brazil’s infant immunization schedule with recommended upper age limits for initiating (by age 14 weeks) and completing (by age 24 weeks) the two-dose series to minimize age-specific risk of intussusception following rotavirus vaccination. Several years after introduction, estimated coverage with rotavirus vaccine (83%) was lower compared to coverage for other recommended childhood immunizations (≥94%). Methods We analyzed data from Brazil’s national immunization program on uptake of oral rotavirus vaccine by geographic region and compared administrative coverage estimates for first and second doses of oral rotavirus vaccine (Rota1 and Rota2) with first and second doses of diphtheria-tetanus-pertussis-Haemophilus influenzae type b vaccine (DTP-Hib1 and DTP-Hib2). For 27 Brazilian cities, we compared differences between estimated rotavirus and DTP-Hib coverage in 2010 with delayed receipt of DTP-Hib vaccine among a cohort of children surveyed before rotavirus introduction. Results In 2010, infant vaccination coverage was 99.0% for DTP-Hib1 versus 95.2% for Rota1 (3.8% difference), and 98.4% for DTP-Hib2 versus 83.0% for Rota2 (15.4% difference), with substantial regional variation. Differences between DTP-Hib and rotavirus vaccination coverage in Brazilian cities correlated with delay in DTP-Hib vaccination among children surveyed. Age restrictions for initiating and completing the rotavirus vaccination series likely contributed to lower coverage with rotavirus vaccine in Brazil. Conclusion To maximize benefits of rotavirus vaccination, strategies are needed to improve timeliness of routine immunizations; monitoring rotavirus vaccine uptake and intussusception risk is needed to guide further recommendations for rotavirus vaccination. PMID:23313652
NASA Astrophysics Data System (ADS)
Lindfors, A. V.; Arola, A.; Kaurola, J.; Taalas, P.; SvenøE, T.
2003-08-01
A method for estimating daily erythemal UV doses using total ozone, sunshine duration, and snow depth has been developed. The method consists of three steps: (1) daily clear-sky UV doses were simulated using the UVSPEC radiative transfer program, with daily values of total ozone as input data, (2) an empirical relationship was sought between the simulated clear-sky UV doses, the measured UV doses, and the duration of bright sunshine, and (3) daily erythemal UV doses were estimated using this relationship. The method accounts for the varying surface albedo by dividing the period of interest into winter and summer days, depending on the snow depth. Using this method, the daily erythemal UV doses at Sodankylä were estimated for the period 1950-1999. This was done using Tromsø's total ozone together with Sodankylä's own sunshine duration and snow depth as input data. Although the method is fairly simple, the results are in good agreement, even on the daily scale, with the UV radiation measured with the Brewer spectrophotometer at Sodankylä. Over the period 1950-1999 a statistically significant increasing trend of 3.9% per decade in erythemal UV doses was found for March. The fact that this trend is much more pronounced during the latter part of the period, which is also the case for April, suggests a connection to the stratospheric ozone depletion. For July, on the other hand, a significant decreasing trend of 3.3% per decade, supported by the changes in both total ozone and sunshine duration, was found.
State of equity: childhood immunization in the World Health Organization African Region.
Casey, Rebecca Mary; Hampton, Lee McCalla; Anya, Blanche-Philomene Melanga; Gacic-Dobo, Marta; Diallo, Mamadou Saliou; Wallace, Aaron Stuart
2017-01-01
In 2010, the Global Vaccine Action Plan called on all countries to reach and sustain 90% national coverage and 80% coverage in all districts for the third dose of diphtheria-tetanus-pertussis vaccine (DTP3) by 2015 and for all vaccines in national immunization schedules by 2020. The aims of this study are to analyze recent trends in national vaccination coverage in the World Health Organization African Region andto assess how these trends differ by country income category. We compared national vaccination coverage estimates for DTP3 and the first dose of measles-containing vaccine (MCV) obtained from the World Health Organization (WHO)/United Nations Children's Fund (UNICEF) joint estimates of national immunization coverage for all African Region countries. Using United Nations (UN) population estimates of surviving infants and country income category for the corresponding year, we calculated population-weighted average vaccination coverage by country income category (i.e., low, lower middle, and upper middle-income) for the years 2000, 2005, 2010 and 2015. DTP3 coverage in the African Region increased from 52% in 2000 to 76% in 2015,and MCV1 coverage increased from 53% to 74% during the same period, but with considerable differences among countries. Thirty-six African Region countries were low income in 2000 with an average DTP3 coverage of 50% while 26 were low income in 2015 with an average coverage of 80%. Five countries were lower middle-income in 2000 with an average DTP3 coverage of 84% while 12 were lower middle-income in 2015 with an average coverage of 69%. Five countries were upper middle-income in 2000 with an average DTP3 coverage of 73% and eight were upper middle-income in 2015 with an average coverage of 76%. Disparities in vaccination coverage by country persist in the African Region, with countries that were lower middle-income having the lowest coverage on average in 2015. Monitoring and addressing these disparities is essential for meeting global immunization targets.
Roberts, Elizabeth S; Tapp, Tiffany; Trimmer, Ann; Roycroft, Linda; King, Stephen
2016-11-01
Objectives This study was designed to evaluate the efficacy and safety of reducing ciclosporin (CsA) dosing frequency from daily to every other day (EOD) or twice a week (TW) according to clinical response in cats with hypersensitivity dermatitis (HD) and treated with CsA. Methods One hundred and ninety-one cats with HD were given 7 mg/kg CsA daily for at least 4 weeks. Depending on clinical response, the dosing frequency was tapered from daily to EOD over the next 4 weeks and further to TW for an additional 4 weeks. Safety was evaluated through physical examinations, clinical pathology and the monitoring of adverse events (AEs). Results The majority of cats were able to have their dose of CsA tapered to either EOD (15.5%) or TW (62.9%) according to the clinical response. Observed AEs were most frequently mild and self-limiting vomiting and diarrhea. A higher percentage of AEs occurred with daily administration (73%) compared with other dosing regimens (27%). Conclusions and relevance Following 4 weeks of daily dosing at 7 mg/kg, CsA may be tapered to EOD or TW while maintaining the desired therapeutic response in cats with HD. Additionally, CsA appears to be well tolerated with fewer AEs at EOD or TW dosing. Establishing the lowest effective dosing frequency of CsA improves the drug's safety profile.
Recent El Niño brought downpour of media coverage
NASA Astrophysics Data System (ADS)
Hare, Steven R.
Media coverage of the 1997-1998 tropical ocean warming event made the term “El Nino” a household word. So pervasive was coverage of El Nino that it became the fodder of late night talk show monologues and an oft-invoked gremlin responsible for many of society's ailments. As a fisheries biologist studying climate impacts on marine resources, I followed the event very closely and created an El Nino Web site (http://www. iphc.washington.edu/PAGES/IPHC/Staff/ hare/html/1997ENSO/ 1997ENSO.html) in the spring of 1997 when the magnitude of the event was becoming obvious.As part of my daily routine in updating the Web page, I began tracking El Nino media coverage over the Internet. Between June 1997 and July 1998,1 accumulated links to stories about El Nino. I attempted to maintain a constant level of effort so that the number of stories accurately reflected the level of coverage given the event as it progressed. In fisheries lingo, this is known as a Catch Per Unit Effort (CPUE) index. Because Internet content is often removed after a period of time, a retrospective accumulation of daily stories would not yield as accurate a count as the contemporary CPUE index I maintained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, H; Ferjani, S; Masssey, V
Purpose: Perform dosimetric comparison between planned and delivered dose in the junction area, measure daily dose variation in the arc junction area for pediatric patients treated for medulloblastoma using Craniospinal axis irradiation(CSI) Material and methods Dose comparison in the junction area, daily dose variation in the arc junction area for a Rando Phantom and 5 pediatric patients treated using CSI technique were analyzed. Plans were created using the Eclipse treatment planning system. Two arcs for cranium and 1 arc for spine region were used. Planar dose matrix was created by projecting phantom and patient plan into the ArcCheck phantom. EBT3more » film was placed in the middle of ArcCheck plug to measure dose distribution in the junction areaDuring patient treatment, strip of EBT3 film was placed daily at each junction area for verification. EBT3 films were scanned using a flatbed scanner, Epson Expression 10000 XL. Film QA pro software was used to analyze film. Scanning and analysis was performed according to vendor recommendations and AAPM TG-55 report. Films were scanned and analyzed daily after each treatment and at the end of treatment course. Planar dose distributions from films were compared with planar dose distribution from treatment planning system. Results: Comparison of planned vs. measured dose distributions for patients have passing rates of 90%–100% with 3% and 3 mm gamma analysis. In some of the treatment fractions, daily setup film showed variation in dose distribution in the junction area. Conclusion: It is critical to measure dose distribution in the arc junction area and use additional quality assurance measures to verify daily setup for CSI patient where one or more junctions are present. EBT3 film prove to be a good tool to achieve this task considering flexibility associated with the film such as symmetry, self-developing and ease of use.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frame, C; Ding, G
Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning errormore » on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.« less
Coverage-based constraints for IMRT optimization
NASA Astrophysics Data System (ADS)
Mescher, H.; Ulrich, S.; Bangert, M.
2017-09-01
Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.
HPV Vaccination Coverage of Male Adolescents in the United States
Lu, Peng-jun; Yankey, David; Jeyarajah, Jenny; O’Halloran, Alissa; Elam-Evans, Laurie D.; Smith, Philip J.; Stokley, Shannon; Singleton, James A.; Dunne, Eileen F.
2018-01-01
Background In 2011, the Advisory Committee for Immunization Practices (ACIP) recommended routine use HPV vaccine for male adolescents. Methods We used the 2013 National Immunization Survey-Teen (NIS-Teen) data to assess HPV vaccine uptake (≥1 dose) and series completion (≥3 doses). Multivariable logistic regression analysis and a predictive marginal model were conducted to identify independent predictors of vaccination among adolescent males aged 13–17 years. Results HPV vaccination coverage with ≥1 dose was 34.6% while series completion (≥3 doses) was 13.9%. Coverage was significantly higher among non-Hispanic blacks and Hispanics compared with non-Hispanic white males. Multivariable logistic regression showed that characteristics independently associated with a higher likelihood of HPV vaccination (≥1 dose) included: being non-Hispanic black race or Hispanic ethnicity, having mothers who were widowed, divorced, or separated, having 1–3 physician contacts in the past 12 months, a well-child visit at age 11–12 years, having one or two vaccination providers, living in urban or suburban areas, and receiving vaccinations from more than one type of facility (p<0.05). Having mothers with some college or college education, having a higher family income to poverty ratio, living in South or Midwest, and receiving vaccinations from all STD/school/teen clinics or other facilities were independently associated with a lower likelihood of HPV vaccination (p<0.05). Conclusions Following recommendations for routine HPV vaccination among male adolescents, uptake in 2013 was low in males. Increased efforts are needed to improve vaccination coverage, especially for those who are least likely to be vaccinated. PMID:26504124
Kilpinen, Susanne; Spillmann, Thomas; Westermarck, Elias
2014-08-06
Despite its wide acceptance as a treatment for canine chronic enteropathies, the macrolide antibiotic tylosin lacks official oral dosage recommendations. Not even textbooks share consensus about the dose; daily recommendations vary from 25 to 80 mg/kg and dosing intervals from one to three times daily. All eight dogs responded to the 5 mg/kg dose, and six of seven dogs responded to the 15 mg/kg dose. The mean fecal consistency scores at the 25 mg/kg tylosin dosage were no significantly different from scores at the 5 mg/kg or 15 mg/kg tylosin dosages (P=0.672, P=0.345). Interestingly, 14/15 (93%) of the dogs responding to a dose of 25 mg/kg tylosin once daily for seven days also responded to the lower dosages at diarrhea relapse. The data indicate that a suitable dose of tylosin for treating diarrhea relapse in canine TRD could be as low as 5 mg/kg once daily for seven days.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Small, Katherine; Kelly, Chris; Beldham-Collins, Rachael
A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy inmore » 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.« less
Parker, Lucy A; Rumunu, John; Jamet, Christine; Kenyi, Yona; Lino, Richard Laku; Wamala, Joseph F; Mpairwe, Allan M; Muller, Vincent; Llosa, Augusto E; Uzzeni, Florent; Luquero, Francisco J; Ciglenecki, Iza; Azman, Andrew S
2017-06-01
In June 2015, a cholera outbreak was declared in Juba, South Sudan. In addition to standard outbreak control measures, oral cholera vaccine (OCV) was proposed. As sufficient doses to cover the at-risk population were unavailable, a campaign using half the standard dosing regimen (one-dose) targeted high-risk neighborhoods and groups including neighbors of suspected cases. Here we report the operational details of this first public health use of a single-dose regimen of OCV and illustrate the feasibility of conducting highly targeted vaccination campaigns in an urban area. Neighborhoods of the city were prioritized for vaccination based on cumulative attack rates, active transmission and local knowledge of known cholera risk factors. OCV was offered to all persons older than 12 months at 20 fixed sites and to select groups, including neighbors of cholera cases after the main campaign ('case-triggered' interventions), through mobile teams. Vaccination coverage was estimated by multi-stage surveys using spatial sampling techniques. 162,377 individuals received a single-dose of OCV in the targeted neighborhoods. In these neighborhoods vaccine coverage was 68.8% (95% Confidence Interval (CI), 64.0-73.7) and was highest among children ages 5-14 years (90.0%, 95% CI 85.7-94.3), with adult men being less likely to be vaccinated than adult women (Relative Risk 0.81, 95% CI: 0.68-0.96). In the case-triggered interventions, each lasting 1-2 days, coverage varied (range: 30-87%) with an average of 51.0% (95% CI 41.7-60.3). Vaccine supply constraints and the complex realities where cholera outbreaks occur may warrant the use of flexible alternative vaccination strategies, including highly-targeted vaccination campaigns and single-dose regimens. We showed that such campaigns are feasible. Additional work is needed to understand how and when to use different strategies to best protect populations against epidemic cholera.
Progress Toward Measles Elimination - African Region, 2013-2016.
Masresha, Balcha G; Dixon, Meredith G; Kriss, Jennifer L; Katsande, Reggis; Shibeshi, Messeret E; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Byabamazima, Charles R; Dabbagh, Alya J; Goodson, James L; Mihigo, Richard
2017-05-05
In 2011, the 46 World Health Organization (WHO) African Region (AFR) member states established a goal of measles elimination* by 2020, by achieving 1) ≥95% coverage of their target populations with the first dose of measles-containing vaccine (MCV1) at national and district levels; 2) ≥95% coverage with measles-containing vaccine (MCV) per district during supplemental immunization activities (SIAs); and 3) confirmed measles incidence of <1 case per 1 million population in all countries (1). Two key surveillance performance indicator targets include 1) investigating ≥2 cases of nonmeasles febrile rash illness per 100,000 population annually, and 2) obtaining a blood specimen from ≥1 suspected measles case in ≥80% of districts annually (2). This report updates the previous report (3) and describes progress toward measles elimination in AFR during 2013-2016. Estimated regional MCV1 coverage † increased from 71% in 2013 to 74% in 2015. § Seven (15%) countries achieved ≥95% MCV1 coverage in 2015. ¶ The number of countries providing a routine second MCV dose (MCV2) increased from 11 (24%) in 2013 to 23 (49%) in 2015. Forty-one (79%) of 52 SIAs** during 2013-2016 reported ≥95% coverage. Both surveillance targets were met in 19 (40%) countries in 2016. Confirmed measles incidence in AFR decreased from 76.3 per 1 million population to 27.9 during 2013-2016. To eliminate measles by 2020, AFR countries and partners need to 1) achieve ≥95% 2-dose MCV coverage through improved immunization services, including second dose (MCV2) introduction; 2) improve SIA quality by preparing 12-15 months in advance, and using readiness, intra-SIA, and post-SIA assessment tools; 3) fully implement elimination-standard surveillance †† ; 4) conduct annual district-level risk assessments; and 5) establish national committees and a regional commission for the verification of measles elimination.
Student Publications Localize Conflict in Iraq.
ERIC Educational Resources Information Center
Inouye, Emily
2003-01-01
Notes that high school students have an incredible number of issues they must face daily. Contends that it is vital for a high school newspaper to find a balance between coverage of world events and local occurrences so that everything is relevant to high-school readers. Provides examples of eight high school newspapers' coverage of the 2003 war…
Gautam, Santosh; Franzini, Luisa; Mikhail, Osama I; Chan, Wenyaw; Turner, Barbara J
2016-03-01
Diabetes mellitus (DM) has well known costly complications but we hypothesized that costs of care for chronic pain treated with opioid analgesic (OA) medications would also be substantial. In a statewide, privately insured cohort of 29,033 adults aged 18 to 64 years with DM and noncancer pain who filled OA prescription(s) from 2008 to 2012, our outcomes were costs for specific health care services and total costs per 6-month intervals after the first filled OA prescription. Average daily OA dose (4 categories) and total dose (quartiles) in morphine-equivalent milligrams were calculated per 6-month interval after the first OA prescription and combined into a novel OA dose measure. Associations of OA measures with costs of care (n = 126,854 6-month intervals) were examined using generalized estimating equations adjusted for clinical conditions, psychotherapeutic drugs, and DM treatment. Incremental costs for each type of health care service and total cost of care increased progressively with average daily and total OA dose versus no OAs. The combined OA measure identified the highest incremental total costs per 6-month interval that were increased by $8,389 for 50- to 99-mg average daily dose plus >900 mg total dose and, by $9,181 and $9,958 respectively, for ≥100 mg average daily dose plus 301- to 900-mg or >900 mg total dose. In this statewide DM cohort, total health care costs per 6-month interval increased progressively with higher average daily OA dose and with total OA dose but the greatest increases of >$8,000 were distinguished by combinations of higher average daily and total OA doses. The higher costs of care for opioid-treated patients appeared for all types of services and likely reflects multiple factors including morbidity from the underlying cause of pain, care and complications related to opioid use, and poorer control of diabetes as found in other studies. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.
Cluster Survey Evaluation of a Measles Vaccination Campaign in Jharkhand, India, 2012
Scobie, Heather M.; Ray, Arindam; Routray, Satyabrata; Bose, Anindya; Bahl, Sunil; Sosler, Stephen; Wannemuehler, Kathleen; Kumar, Rakesh; Haldar, Pradeep; Anand, Abhijeet
2015-01-01
Introduction India was the last country in the world to implement a two-dose strategy for measles-containing vaccine (MCV) in 2010. As part of measles second-dose introduction, phased measles vaccination campaigns were conducted during 2010–2013, targeting 131 million children 9 months to <10 years of age. We performed a post-campaign coverage survey to estimate measles vaccination coverage in Jharkhand state. Methods A multi-stage cluster survey was conducted 2 months after the phase 2 measles campaign occurred in 19 of 24 districts of Jharkhand during November 2011–March 2012. Vaccination status of children 9 months to <10 years of age was documented based on vaccination card or mother’s recall. Coverage estimates and 95% confidence intervals (95% CI) for 1,018 children were calculated using survey methods. Results In the Jharkhand phase 2 campaign, MCV coverage among children aged 9 months to <10 years was 61.0% (95% CI: 54.4–67.7%). Significant differences in coverage were observed between rural (65.0%; 95% CI: 56.8–73.2%) and urban areas (45.6%; 95% CI: 37.3–53.9%). Campaign awareness among mothers was low (51.5%), and the most commonly reported reason for non-vaccination was being unaware of the campaign (69.4%). At the end of the campaign, 53.7% (95% CI: 46.5–60.9%) of children 12 months to <10 years of age received ≥2 MCV doses, while a large proportion of children remained under-vaccinated (34.0%, 95% CI: 28.0–40.0%) or unvaccinated (12.3%, 95% CI: 9.3–16.2%). Conclusions Implementation of the national measles campaign was a significant achievement towards measles elimination in India. In Jharkhand, campaign performance was below the target coverage of ≥90% set by the Government of India, and challenges in disseminating campaign messages were identified. Efforts towards increasing two-dose MCV coverage are needed to achieve the recently adopted measles elimination goal in India and the South-East Asia region. PMID:26010084
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
Intrathecal Baclofen Dosing Regimens: A Retrospective Chart Review.
Clearfield, Jacob S; Nelson, Mary Elizabeth S; McGuire, John; Rein, Lisa E; Tarima, Sergey
2016-08-01
To examine dosing patterns in patients receiving baclofen via intrathecal baclofen pumps to assess for common patterns by diagnosis, ambulation ability, and affected limbs distribution. This trial study included 25 patients with baclofen pumps selected from the 356 patients enrolled in our center's baclofen pump program. Selection was done by splitting all patients into diagnostic categories of stroke, multiple sclerosis, traumatic/anoxic brain injury, cerebral palsy, and spinal cord injury, and then, five patients were randomly selected from each diagnosis.A systematic chart review was then conducted for each patient from Jan 1, 2008, through September 16, 2013, to look at factors including mean daily dose at end of study, and among those implanted during the study mean initial stable dose and time to initial stable dose. Analysis of mean daily dose across diagnoses found significant differences, with brain injury, cerebral palsy, and spinal cord injury patients having higher doses while multiple sclerosis and stroke patients required lower doses. Nonambulatory patients strongly trended to have higher daily doses than ambulatory patients. Similar trends of mean initial stable dose being higher in a similar pattern as that of end mean daily dose were seen according to diagnoses and ambulatory status, although statistical significance could not be achieved with the small sample size. Significant differences in dosing were found between diagnoses and trended to differ by ambulatory status at the end of the study, and similar trends could be observed in achieving initial stable dose. © 2015 International Neuromodulation Society.
Khan, Nabeel; Abbas, Ali M; Koleva, Yordanka N; Bazzano, Lydia A
2013-05-01
There are limited data about the long-term follow-up of patients with ulcerative colitis (UC) maintained on high versus low doses of mesalamine. We evaluated the best long-term average daily dose that would keep the disease in remission. Nationwide ulcerative colitis data were obtained from the Veterans Affairs health care system for the period 2001 to 2011. Those who started mesalamine maintenance during this period were included. Average daily dose and the level of adherence were assessed for the period between the first mesalamine dispense and the date of first flare defined as the first filling of 40 mg/day or more of oral prednisone or any dose of intravenous steroids. Patients with ulcerative colitis maintained on an average daily dose 2.4 to 2.8 g/day (low dose) were compared with 4.4 to 4.8 g/day (high dose). Adherence was assessed using continuous single interval medication availability indicator. We included 4452 patients with a median follow-up of 6 years. There was no significant reduction in the risk of flares when comparing high versus low average mesalamine dose among patients with high [hazard ratio = 0.96, P = 0.8)] and medium (hazard ratio = 0.74, P = 0.17) adherence. However, there was a significant reduction in the risk of flares with high dose of mesalamine among patients with low adherence (hazard ratio = 0.28, P = 0.003). Our data show that when starting a patient on mesalamine, there is no difference in the long-term flare risk between low versus high average daily dose as long as the patients have a high to moderate level of adherence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harron, Elizabeth, E-mail: elizabeth.harron@nuh.nhs.uk; Lewis, Joanne
2012-07-01
The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared inmore » terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.« less
Wagner, Abram L; Zhang, Ying; Montgomery, JoLynn P; Ding, Yaxing; Carlson, Bradley F; Boulton, Matthew L
2014-08-29
Measles is a highly infectious disease, and timely administration of two doses of vaccine can ensure adequate protection against measles for all ages in a population. This study aims to estimate the proportion of children aged 8 months to 6 years vaccinated on time with measles-containing vaccines (MCV) and vaccinated during the 2008 and 2010 measles supplementary immunization activities. This study also characterizes differences in mean age at vaccination and vaccination timeliness by demographic characteristics, and describes maternal knowledge of measles vaccination. Immunization records were selected from a convenience sample of immunization clinics in Tianjin, China. From the records, overall vaccination coverage and timely vaccination coverage were calculated for different demographic groups. Mothers were also interviewed at these clinics to ascertain their knowledge of measles vaccination. Within the 329 immunization clinic records, child's birth year and district of residence were found to be significant predictors of different measures of vaccine timeliness. Children born in 2009 had a lower age at MCV dose 2 administration (17.96 months) than children born in 2005 (22.00 months). Children living in Hebei, a district in the urban center of Tianjin were less likely to be vaccinated late than children living in districts further from the urban core of Tianjin. From the 31 interviews with mothers, most women believed that timely vaccination was very important and more than one dose was very necessary; most did not know whether their child needed another dose. When reviewing MCV coverage in China, most studies do not consider timeliness. However, this study shows that overall vaccination coverage can greatly overestimate vaccination coverage within certain segments of the population, such as young infants.
Progress in global measles control, 2000-2010.
2012-02-03
In 1980, before widespread global use of measles vaccine, an estimated 2.6 million measles deaths occurred worldwide. In 2001, to accelerate the reduction in measles cases achieved by vaccination, the World Health Organization (WHO) and the United Nations Children's Fund (UNICEF) developed a strategy to deliver 2 doses of measles-containing vaccine (MCV) to all children through routine services and supplementary immunization activities (SIAs) and improved disease surveillance. After implementation of this strategy, the estimated number of annual measles deaths worldwide decreased from 733,000 in 2000 to 164,000 in 2008. In 2010, the World Health Assembly endorsed the following measles objectives for 2015: 1) raise routine coverage with the first dose of MCV (MCV1) for children aged 1 year to ≥90% nationally and ≥80% in every district or equivalent administrative unit, 2) reduce and maintain annual measles incidence at <5 cases per million, and 3) reduce measles mortality by ≥95% from the 2000 estimate. During 2000-2010, global MCV1 coverage increased from 72% to 85% with approximately 1 billion children vaccinated during measles SIAs. Reported measles cases decreased from 2000 to 2008, remained stable in 2009, and increased in 2010. By the end of 2010, 40% of countries still had not met the incidence target of <5 cases per million. Key challenges must be overcome to meet the 2015 objectives, including 1) declining political and financial commitments to measles control, 2) failure to reach uniform high coverage with 2 doses of MCV through routine services or SIAs, and 3) inadequate monitoring subnationally of coverage with the first and second dose of MCV to guide interventions to increase coverage.
Issell, Brian F; Gotay, Carolyn C; Pagano, Ian; Franke, Adrian A
2009-01-01
ABSTRACT. The purpose of this study was to determine a maximum tolerated dose of noni in cancer patients and whether an optimal quality of life-sustaining dose could be identified as an alternative way to select a dose for subsequent Phase II efficacy trials. Dose levels started at two capsules twice daily (2 g), the suggested dose for the marketed product, and were escalated by 2 g daily in cohorts of at least five patients until a maximum tolerated dose was found. Patients completed subscales of the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 quality of life (physical functioning, pain, and fatigue) the brief fatigue inventory (BFI), questionnaires at baseline and at approximately 4-week intervals. Blood and urine were collected at baseline and at approximately 4-week intervals for measurement of scopoletin. Fifty-one patients were enrolled at seven dose levels. The maximum tolerated dose was six capsules four times daily (12 g). Although no dose-limiting toxicity was found, seven of eight patients at the next level (14 g), withdrew due to the challenges of ingesting so many capsules. There were dose-related differences in self-reported physical functioning and pain and fatigue control. Overall, patients taking three or four capsules four times daily experienced better outcomes than patients taking lower or higher doses. Blood and urinary scopoletin concentrations related to noni dose. We concluded that it is feasible to use quality of life measures to select a Phase II dose. Three or four capsules four times daily (6-8 g) is recommended when controlling fatigue, pain, and maintaining physical function are the efficacies of interest. Scopoletin, a bioactive component of noni fruit extract, is measurable in blood and urine following noni ingestion and can be used to study the pharmacokinetics of noni in cancer patients.
An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada
Deeks, Shelley L.; Lim, Gillian H.; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S.
2011-01-01
Background This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Methods Information on confirmed cases of mumps was retrieved from Ontario’s integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R0) represents the average number of new infections per case in a fully susceptile population, and R0 values of between 4 and 10 were considered for varying levels of vaccine effectiveness. Results A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Interpretation Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs. PMID:21576295
An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada.
Deeks, Shelley L; Lim, Gillian H; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S
2011-06-14
This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Information on confirmed cases of mumps was retrieved from Ontario's integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R(0)) represents the average number of new infections per case in a fully susceptible population, and R(0) values of between 4 and 10 were considered for varying levels of vaccine effectiveness. A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs.
Li, Xi; Wiesen, Eric; Diorditsa, Sergey; Toda, Kohei; Duong, Thi Hong; Nguyen, Lien Huong; Nguyen, Van Cuong; Nguyen, Tran Hien
2016-02-03
Adverse Events Following Immunization in Viet Nam in 2013 led to substantial reductions in hepatitis B vaccination coverage (both the birth dose and the three-dose series). In order to estimate the impact of the reduction in vaccination coverage on hepatitis B transmission and future mortality, a widely-used mathematical model was applied to the data from Viet Nam. Using the model, we estimated the number of chronic infections and deaths that are expected to occur in the birth cohort in 2013 and the number of excessive infections and deaths attributable to the drop in immunization coverage in 2013. An excess of 90,137 chronic infections and 17,456 future deaths were estimated to occur in the 2013 birth cohort due to the drop in vaccination coverage. This analysis highlights the importance of maintaining high vaccination coverage and swiftly responding to reported Adverse Events Following Immunization in order to regain consumer confidence in the hepatitis B vaccine. Copyright © 2015 World Health Organization; licensee Elsevier. Published by Elsevier Ltd.. All rights reserved.
Altpeter, Ekkehardt; Wymann, Monica N; Richard, Jean-Luc; Mäusezahl-Feuz, Mirjam
2018-06-01
To evaluate the impact of the Swiss measles elimination strategy-including a mass media campaign-on vaccination coverage and awareness among young adults aged 20-29 years. Comparison of the results of two cross-sectional population surveys in 2012 and 2015. Documented vaccination coverage increased from 77 to 88% for two doses of measles vaccine. Major determinants of complete vaccination were survey year, birth cohort, sex and the absence of prior measles disease. If birth cohort and prior history of measles disease are included as factors in a multivariate model, the difference between 2012 and 2015 vanishes. The marked increase in complete measles vaccination coverage is due to a cohort effect, owing to the introduction of the second dose of vaccine in 1996. Most of the vaccinations were administered before the national strategy was implemented and vaccination catch-ups did not increase during the campaign in young adults. Nevertheless, this study provides evidence of an improvement in the awareness of measles and measles vaccination in young adults, which may result in an impact on measles vaccination coverage in the near future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denine, E.P.; Stout, L.D.; Peckham, J.C.
1978-11-10
Dose-limiting gastrointestinal toxicosis was qualitatively similar in dogs, monkeys, and mice. In dogs and monkeys, anorexia and/or oligodipsia were cardinal signs. Severity of intoxication was indicated by progression to a diarrheal syndrome. Intoxication of the erythron was indicated in the dog and monkey studies. Quantitatively, mice were the most resistant to toxicity, and monkeys were more resistant than dogs. In dogs, fractionation of a single dose to five daily doses resulted in marked cumulative toxicity. Further fractionation to 10 daily doses produced only additive intoxication. Fractionation of a single dose to weekly doses offered some protection from additive toxicity. Similarmore » results were obtained when 5 daily doses were fractionated to three 5-day courses of treatment separated by 9-day rest periods.« less
Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos
2010-09-21
A low-energy electronic brachytherapy source (EBS), the model S700 Axxent x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V(100) reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V(100) to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.
NASA Astrophysics Data System (ADS)
Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos
2010-09-01
A low-energy electronic brachytherapy source (EBS), the model S700 Axxent™ x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V100 reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V100 to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.
2014-01-01
Background Despite its wide acceptance as a treatment for canine chronic enteropathies, the macrolide antibiotic tylosin lacks official oral dosage recommendations. Not even textbooks share consensus about the dose; daily recommendations vary from 25 to 80 mg/kg and dosing intervals from one to three times daily. The objective of this prospective, single-blinded, two-arm parallel, clinical field trial was to determine whether doses of 5 mg/kg or 15 mg/kg tylosin administered orally once daily for seven days would have a similar effect on fecal consistency in diarrhea relapses to that of a 25 mg/kg dose of tylosin administered once daily for seven days, a dosage that has proved effective in controlling canine tylosin-responsive diarrhea (TRD). A further objective was to compare the efficacy of the 5 mg/kg and 15 mg/kg tylosin dosages. Fifteen client-owned dogs diagnosed with TRD that had responded to a dose of 25 mg/kg tylosin once daily for seven days were enrolled in the study. After a relapse of diarrhea the dogs were allocated into two groups receiving tylosin orally in doses of either 5 mg/kg or 15 mg/kg once daily for seven days. The owners were blinded to the dosage. The elimination of diarrhea was the main criterion in assessing treatment success. The mean fecal consistency score of the last three treatment days for all dosages, including 25 mg/kg, as evaluated by the owners according to a standardized fecal scoring system, served as the primary outcome measures. Results All eight dogs responded to the 5 mg/kg dose, and six of seven dogs responded to the 15 mg/kg dose. The mean fecal consistency scores at the 25 mg/kg tylosin dosage were no significantly different from scores at the 5 mg/kg or 15 mg/kg tylosin dosages (P = 0.672, P = 0.345). Conclusions Interestingly, 14/15 (93%) of the dogs responding to a dose of 25 mg/kg tylosin once daily for seven days also responded to the lower dosages at diarrhea relapse. The data indicate that a suitable dose of tylosin for treating diarrhea relapse in canine TRD could be as low as 5 mg/kg once daily for seven days. PMID:25096196
Azelaic acid 15% gel once daily versus twice daily in papulopustular rosacea.
Thiboutot, Diane M; Fleischer, Alan B; Del Rosso, James Q; Graupe, Klaus
2008-06-01
Twice-daily azelaic acid (AzA) is the conventional regimen for papulopustular rosacea, but once-daily AzA may be equally effective, with greater convenience and dosing flexibility. In order to test this hypothesis, an exploratory study was conducted. The evaluable efficacy population of this 12-week double-blind, parallel-group study included 72 patients and the population that was used to report safety results included 92 patients. Baseline characteristics were comparable between the once-daily and twice-daily study groups. Evaluations were performed at baseline and at weeks 4, 8, and 12. No significant difference was found between the once-daily and twice-daily groups at the end of study therapy in mean investigator global assessment (IGA) scores, treatment success, or treatment response. The mean number of inflammatory lesions, the intensity of erythema intensity, and the intensity of telangiectasia at treatment end were likewise not significantly different (P>.205 for all). More than 90% of subjects in each group rated cosmetic acceptability of this AzA gel as satisfactory or better. Based on these findings and those of prior studies, once-daily AzA 15% gel can therefore be utilized as a safe, effective, and economical dosing option for the treatment of mild-to-moderate papulopustular rosacea. Once-daily dosing of AzA 15% gel was well accepted by patients and can offer considerable dosing flexibility and convenience for the patient as well as for the dermatologist.
Supine craniospinal irradiation in pediatric patients by proton pencil beam scanning.
Farace, Paolo; Bizzocchi, Nicola; Righetto, Roberto; Fellin, Francesco; Fracchiolla, Francesco; Lorentini, Stefano; Widesott, Lamberto; Algranati, Carlo; Rombi, Barbara; Vennarini, Sabina; Amichetti, Maurizio; Schwarz, Marco
2017-04-01
Proton therapy is the emerging treatment modality for craniospinal irradiation (CSI) in pediatric patients. Herein, special methods adopted for CSI at proton Therapy Center of Trento by pencil beam scanning (PBS) are comprehensively described. Twelve pediatric patients were treated by proton PBS using two/three isocenters. Special methods refer to: (i) patient positioning in supine position on immobilization devices crossed by the beams; (ii) planning field-junctions via the ancillary-beam technique; (iii) achieving lens-sparing by three-beams whole-brain-irradiation; (iv) applying a movable-snout and beam-splitting technique to reduce the lateral penumbra. Patient-specific quality assurance (QA) program was performed using two-dimensional ion chamber array and γ-analysis. Daily kilovoltage alignment was performed. PBS allowed to obtain optimal target coverage (mean D98%>98%) with reduced dose to organs-at-risk. Lens sparing was obtained (mean D1∼730cGyE). Reducing lateral penumbra decreased the dose to the kidneys (mean Dmean<600cGyE). After kilovoltage alignment, potential dose deviations in the upper and lower junctions were small (average 0.8% and 1.2% respectively). Due to imperfect modeling of range shifter, QA showed better agreements between measurements and calculations at depths >4cm (mean γ>95%) than at depths<4cm. The reported methods allowed to effectively perform proton PBS CSI. Copyright © 2017 Elsevier B.V. All rights reserved.
Shen, Jie; Goodkin, Margot L; Tong, Warren; Attar, Mayssa
2017-01-01
Purpose Fixed-combination medications can benefit patients requiring multiple agents to lower their intraocular pressure (IOP), but combining agents with complementary mechanisms of action is challenging if their dosing frequency differs. This study compares in vivo pharmacokinetic and ocular tolerability of bimatoprost 0.01% ophthalmic solutions dosed once or twice daily. Reports of twice-daily dosing in glaucoma patients are also reviewed. Methods New Zealand White rabbits were administered bimatoprost 0.01% monotherapy or fixed-combination bimatoprost 0.01%/brimonidine 0.1%, once or twice daily in both eyes for 4 days. Ocular tissues were harvested and analyzed by liquid chromatography-tandem mass spectrometry. The pharmacokinetic parameters calculated included maximum observed concentration, time to maximum concentration, and area under the concentration-time curve. Results Due to extensive metabolism, bimatoprost concentration was below the quantitation limit by 1 hour post-dose in all samples. Bimatoprost acid exposure, however, could be measured up to 6–8 hours post-dose and was similar in the aqueous humor and iris-ciliary body (pharmacological site of action) of animals treated once or twice daily with either bimatoprost 0.01% or fixed-combination bimatoprost 0.01%/brimonidine 0.1%. Increasing dosage frequency in rabbits did not raise the incidence of drug-related conjunctival hyperemia (most common adverse event associated with bimatoprost use in humans), suggesting comparable ocular tolerability of the once- and twice-daily regimens for each formulation. Conclusion Bimatoprost 0.01% administered once or twice daily as monotherapy and in fixed-combination with brimonidine 0.1% in rabbits show similar pharmacokinetic profiles of bimatoprost acid, especially in the iris-ciliary body. Key findings from previous clinical studies suggest that by varying the concentration of benzalkonium chloride (a preservative with corneal penetration-enhancing properties), formulations of bimatoprost 0.01% can be administered once or twice daily. These findings support development of bimatoprost 0.01%-based fixed-dose combination therapies administered twice daily for patients who require multiple adjunctive medications to control their IOP. PMID:29026287
Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, Alice Y., E-mail: hoa1234@mskcc.org; Patel, Nisha; Ohri, Nisha
To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV)more » (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of the IMNs. Refinement of radiation techniques in reconstructed patients who require comprehensive nodal irradiation is warranted.« less
12 CFR 704.18 - Fidelity bond coverage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... minimum requirements: Daily average net assets Minimumbond (million) Less than $50 million $1.0 $50-$99 million 2.0 $100-$499 million 4.0 $500-$999 million 6.0 $1.0-$1.999 billion 8.0 $2.0-$4.999 billion 10.0... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Fidelity bond coverage. 704.18 Section 704.18...
12 CFR 704.18 - Fidelity bond coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... minimum requirements: Daily average net assets Minimumbond (million) Less than $50 million $1.0 $50-$99 million 2.0 $100-$499 million 4.0 $500-$999 million 6.0 $1.0-$1.999 billion 8.0 $2.0-$4.999 billion 10.0... 12 Banks and Banking 6 2011-01-01 2011-01-01 false Fidelity bond coverage. 704.18 Section 704.18...
ERIC Educational Resources Information Center
Heuterman, Thomas H.
Press coverage of a sizeable Japanese population in the State of Washington has gone unexamined by mass media scholars. A study of the "Wapato Independent" between the time of the alien land laws in the early 1920s and Pearl Harbor shows that while the Japanese received routine coverage of their daily activities, hostile rhetoric by…
A Content Analysis of News Media Coverage of the Accident at Three Mile Island.
ERIC Educational Resources Information Center
Stephens, Mitchell; Edison, Nadyne G.
A study was conducted for the President's Commission on the Accident at Three Mile Island to analyze coverage of the accident by ten news organizations: two wire services, three commercial television networks, and five daily newspapers. Copies of all stories and transcripts of news programs during the first week of the accident were examined from…
Selective robust optimization: A new intensity-modulated proton therapy optimization strategy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Yupeng; Niemela, Perttu; Siljamaki, Sami
2015-08-15
Purpose: To develop a new robust optimization strategy for intensity-modulated proton therapy as an important step in translating robust proton treatment planning from research to clinical applications. Methods: In selective robust optimization, a worst-case-based robust optimization algorithm is extended, and terms of the objective function are selectively computed from either the worst-case dose or the nominal dose. Two lung cancer cases and one head and neck cancer case were used to demonstrate the practical significance of the proposed robust planning strategy. The lung cancer cases had minimal tumor motion less than 5 mm, and, for the demonstration of the methodology,more » are assumed to be static. Results: Selective robust optimization achieved robust clinical target volume (CTV) coverage and at the same time increased nominal planning target volume coverage to 95.8%, compared to the 84.6% coverage achieved with CTV-based robust optimization in one of the lung cases. In the other lung case, the maximum dose in selective robust optimization was lowered from a dose of 131.3% in the CTV-based robust optimization to 113.6%. Selective robust optimization provided robust CTV coverage in the head and neck case, and at the same time improved controls over isodose distribution so that clinical requirements may be readily met. Conclusions: Selective robust optimization may provide the flexibility and capability necessary for meeting various clinical requirements in addition to achieving the required plan robustness in practical proton treatment planning settings.« less
Buprenorphine transdermal system utilization.
Wallace, Laura; Kadakia, Aditi
2017-01-01
To evaluate utilization patterns in patients initiating buprenorphine transdermal system (BTDS), CIII, and estimate the proportion decreasing their total opioid dose over time. This retrospective cohort study used data from the Truven Health Analytics MarketScan® Commercial Claims and Encounters Database from 1 January 2011 through 31 December 2015. Eligible individuals were adults aged 18-64 years newly dispensed BTDS (index prescription) who had at least six months of insurance coverage prior to (baseline period) and following (study period) the index prescription. Back and neck pain was the most common pain condition in the study population (n = 31,533) and 88% were dispensed opioids in the baseline period. Nearly half (48%) received BTDS in a strength of 10 mcg/hour as their index prescription. Most (80%) patients prescribed BTDS had concomitant prescriptions for other opioids, chiefly immediate-release (IR) opioids (77%). During the baseline period, median opioid dose among patients prescribed opioids was 50 morphine-equivalent doses (MED), with 33% of patients using nonsteroidal anti-inflammatory drugs and 44% adjuvant analgesics. During the study period, BTDS use lasted a median 30 days and mean 100 days. Median dose of BTDS remained largely constant, and median dose of all opioids during continuous use of BTDS was 65.6 units MED. However, 24% of patients reduced total units MED from the baseline period (median mean dose, 74.5 units MED) until the end of the study period (42.8). Most patients initiating treatment with BTDS had a history of treatment with IR opioids. Though the average change in total opioid daily dose after patients were prescribed BTDS was modest, an important subpopulation of approximately one-quarter of patients were able to markedly reduce their total units MED compared with prior opioid therapy. BTDS should be investigated as an option to help patients step down from higher opioid doses.
Determinants of vaccination coverage in rural Nigeria
Odusanya, Olumuyiwa O; Alufohai, Ewan F; Meurice, Francois P; Ahonkhai, Vincent I
2008-01-01
Background Childhood immunization is a cost effective public health strategy. Expanded Programme on Immunisation (EPI) services have been provided in a rural Nigerian community (Sabongidda-Ora, Edo State) at no cost to the community since 1998 through a privately financed vaccination project (private public partnership). The objective of this survey was to assess vaccination coverage and its determinants in this rural community in Nigeria Methods A cross-sectional survey was conducted in September 2006, which included the use of interviewer-administered questionnaire to assess knowledge of mothers of children aged 12–23 months and vaccination coverage. Survey participants were selected following the World Health Organization's (WHO) immunization coverage cluster survey design. Vaccination coverage was assessed by vaccination card and maternal history. A child was said to be fully immunized if he or she had received all of the following vaccines: a dose of Bacille Calmette Guerin (BCG), three doses of oral polio (OPV), three doses of diphtheria, pertussis and tetanus (DPT), three doses of hepatitis B (HB) and one dose of measles by the time he or she was enrolled in the survey, i.e. between the ages of 12–23 months. Knowledge of the mothers was graded as satisfactory if mothers had at least a score of 3 out of a maximum of 5 points. Logistic regression was performed to identify determinants of full immunization status. Results Three hundred and thirty-nine mothers and 339 children (each mother had one eligible child) were included in the survey. Most of the mothers (99.1%) had very positive attitudes to immunization and > 55% were generally knowledgeable about symptoms of vaccine preventable diseases except for difficulty in breathing (as symptom of diphtheria). Two hundred and ninety-five mothers (87.0%) had a satisfactory level of knowledge. Vaccination coverage against all the seven childhood vaccine preventable diseases was 61.9% although it was significantly higher (p = 0.002) amongst those who had a vaccination card (131/188, 69.7%) than in those assessed by maternal history (79/151, 52.3%). Multiple logistic regression showed that mothers' knowledge of immunization (p = 0.006) and vaccination at a privately funded health facility (p < 0.001) were significantly correlated with the rate of full immunization. Conclusion Eight years after initiation of this privately financed vaccination project (private-public partnership), vaccination coverage in this rural community is at a level that provides high protection (81%) against DPT/OPV. Completeness of vaccination was significantly correlated with knowledge of mothers on immunization and adequate attention should be given to this if high coverage levels are to be sustained. PMID:18986544
Szauder, Ipoly; Csajági, Eszter; Major, Zsuzsanna; Pavlik, Gabor; Ujhelyi, Gabriella
2015-01-01
Little is known about the effect of twice daily administration of same dose of ACE inhibitor and ARB on the diurnal/nocturnal blood pressure (BP) ratio. We aimed to assess the effect of two widely used long-acting drugs: perindopril and losartan in the treatment of hypertension comparing the once-daily (evening) vs. twice-daily (morning and evening) administration with the same daily doses. Untreated primary hypertensive patients without complaints (a total of 164: 65 men, 99 women, 55.7 ± 13.7 years of age, 41-41 patients per treated groups) were selected with non-dipper phenomenon, estimated by diurnal index (DI) <10%. The effect of evening (8 mg perindopril or 100 mg losartan) vs morning and evening (4-4 mg perindopril or 50-50 mg losartan) administration was determined on a 14-day treatment by ABPM. The mean BP, the percent time elevation index, and the hyperbaric impact decreased in both drug groups. Significant difference was observed in the DI in the case of twice-daily administration vs once-daily evening dosing. The twice-daily administration with the same daily dose of perindopril or losartan seems to be more effective compared to the once daily evening administration in eliminating the non-dipper phenomenon. According to some authors the non-dipping phenomenon increases cardiovascular risk, while others are of the opinion that the association of non-dipping with cardiovascular events does not necessarily mean that selective treatment of non-dipping improves cardiovascular outcomes. © 2015 S. Karger AG, Basel.
Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Aaron M.; Schofield, Deborah; Hacker, Fred
2007-12-01
Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200{sup o} around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volumemore » receiving {>=}5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results.« less
Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer.
Van Benthuysen, Liam; Hales, Lee; Podgorsak, Matthew B
2011-01-01
Several studies have demonstrated that volumetric modulated arc therapy (VMAT) has the ability to reduce monitor units and treatment time when compared with intensity-modulated radiation therapy (IMRT). This study aims to demonstrate that VMAT is able to provide adequate organs at risk (OAR) sparing and planning target volume (PTV) coverage for adenocarcinoma of the distal esophagus while reducing monitor units and treatment time. Fourteen patients having been treated previously for esophageal cancer were planned using both VMAT and IMRT techniques. Dosimetric quality was evaluated based on doses to several OARs, as well as coverage of the PTV. Treatment times were assessed by recording the number of monitor units required for dose delivery. Body V(5) was also recorded to evaluate the increased volume of healthy tissue irradiated to low doses. Dosimetric differences in OAR sparing between VMAT and IMRT were comparable. PTV coverage was similar for the 2 techniques but it was found that IMRT was capable of delivering a slightly more homogenous dose distribution. Of the 14 patients, 12 were treated with a single arc and 2 were treated with a double arc. Single-arc plans reduced monitor units by 42% when compared with the IMRT plans. Double-arc plans reduced monitor units by 67% when compared with IMRT. The V(5) for the body was found to be 18% greater for VMAT than for IMRT. VMAT has the capability to decrease treatment times over IMRT while still providing similar OAR sparing and PTV coverage. Although there will be a smaller risk of patient movement during VMAT treatments, this advantage comes at the cost of delivering small doses to a greater volume of the patient. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Parental knowledge of paediatric vaccination
Borràs, Eva; Domínguez, Àngela; Fuentes, Miriam; Batalla, Joan; Cardeñosa, Neus; Plasencia, Antoni
2009-01-01
Background Although routine vaccination is a major tool in the primary prevention of some infectious diseases, there is some reluctance in a proportion of the population. Negative parental perceptions of vaccination are an important barrier to paediatric vaccination. The aim of this study was to investigate parental knowledge of paediatric vaccines and vaccination in Catalonia. Methods A retrospective, cross-sectional study was carried out in children aged < 3 years recruited by random sampling from municipal districts of all health regions of Catalonia. The total sample was 630 children. Parents completed a standard questionnaire for each child, which included vaccination coverage and knowledge about vaccination. The level of knowledge of vaccination was scored according to parental answers. Results An association was observed between greater vaccination coverage of the 4:4:4:3:1 schedule (defined as: 4 DTPa/w doses, 4 Hib doses, 4 OPV doses, 3 MenC doses and 1 MMR dose) and maternal age >30 years (OR: 2.30; 95% CI: 1.20–4.43) and with a knowledge of vaccination score greater than the mean (OR: 0.45; 95% CI: 0.28–0.72). The score increased with maternal educational level and in parents of vaccinated children. A total of 20.47% of parents stated that vaccines could have undesirable consequences for their children. Of these, 23.26% had no specific information and 17.83% stated that vaccines can cause adverse reactions and the same percentage stated that vaccines cause allergies and asthma. Conclusion Higher vaccination coverage is associated with older maternal age and greater knowledge of vaccination. Vaccination coverage could be raised by improving information on vaccines and vaccination. PMID:19473498
Predicting and comparing long-term measles antibody profiles of different immunization policies.
Lee, M S; Nokes, D J
2001-01-01
Measles outbreaks are infrequent and localized in areas with high coverage of measles vaccine. The need is to assess long-term effectiveness of coverage. Since 1991, no measles epidemic affecting the whole island has occurred in Taiwan, China. Epidemiological models are developed to predict the long-term measles antibody profiles and compare the merits of different immunization policies on the island. The current measles immunization policy in Taiwan, China, is 1 dose of measles vaccine at 9 months of age and 1 dose of measles, mumps and rubella (MMR) vaccine at 15 months of age, plus a 'mop-up' of MMR-unvaccinated schoolchildren at 6 years of age. Refinements involve a change to a two-dose strategy. Five scenarios based on different vaccination strategies are compared. The models are analysed using Microsoft Excel. First, making the assumption that measles vaccine-induced immunity will not wane, the predicted measles IgG seroprevalences in preschool children range from 81% (lower bound) to 94% (upper bound) and in schoolchildren reach 97-98% in all strategy scenarios. Results are dependent on the association of vaccine coverage between the first and second dose of vaccine. Second, if it is assumed that vaccine-induced antibody titres decay, the long-term measles seroprevalence will depend on the initial titres post vaccination, decay rates of antibody titres and cut-off of seropositivity. If MMR coverage at 12 months of age can reach > 90%, it would be worth changing the current policy to 2 doses at 12 months and 6 years of age to induce higher antibody titres. These epidemiological models could be applied wherever a similar stage of measles elimination has been reached.
Best Practices for Intrathecal Baclofen Therapy: Dosing and Long-Term Management.
Boster, Aaron L; Adair, Roy L; Gooch, Judith L; Nelson, Mary Elizabeth S; Toomer, Andrea; Urquidez, Joe; Saulino, Michael
2016-08-01
Intrathecal baclofen (ITB) therapy aims to reduce spasticity and provide functional control. An expert panel consulted on best practices. Pump fill and drug delivery can be started intraoperatively, with monitoring for at least eight hours. Initiate with the 500 mcg/mL concentration. The starting daily dose should be twice the effective bolus screening dose, or the screening dose if the patient had a prolonged response (greater than eight hours) or negative reactions. Oral antispasmodics can be weaned, one drug at a time beginning with oral baclofen after ITB begins. Assessment should occur within 24 hours of a dose change. For adults, daily dose increases may be 5% to 15% once every 24 hours for cerebral-origin spasticity and 10% to 30% once every 24 hours for spinal-origin spasticity. Daily dose increases can be 5% to 15% once every 24 hours for children. Inpatients should be assessed at least every 24 hours and receive rehabilitation. Step dosing can be used for outpatients who cannot return daily. Dosing options include simple continuous dosing, variable 24-hour flex dosing, or regularly scheduled boluses. Patients/caregivers should understand the care plan, responsibilities, and possible side-effects. Low-reservoir alarm dates and refill schedules should be written down, along with emergency contact information. A higher concentration at refill can extend refill intervals, and a bridge bolus must be programmed. Time changes may affect flex dosing. Pump replacement should be scheduled at least three months in advance. ITB dosing is multistep and individualized. © 2016 International Neuromodulation Society.
Wallace, Aaron S.; Ryman, Tove K.; Dietz, Vance
2015-01-01
Background Review of the historical growth in annual vaccination coverage across countries and regions can better inform decision makers’ development of future goals and strategies to improve routine vaccination services. Methods Using the World Health Organization (WHO) and the United Nations Children's Fund estimates of annual national third dose of diphtheria-tetanus-pertussis–containing vaccine (DTP3) and third dose of polio vaccine (POL3) coverage for 1980–2009, we calculated the mean absolute annual rate of change in national DTP3 coverage among all countries (globally) and among countries within each WHO region, as well as the number of years taken by each region to reach specific regional coverage levels. Last, we assessed differences in mean absolute annual rate of change in DTP3 coverage, stratified by baseline level of DTP3 coverage. Results During the 1980s, global DTP3 coverage increased a mean of 5.3 percentage points/year. Annual rate of change decreased to 0.5 percentage points/year in the 1990s and then increased to 0.9 percentage points/year during the 2000s. Mean annual rate of change in coverage across all countries was highest (9.2 percentage points) when national coverage levels were 26%–30% and lowest (−0.9 percentage points) when national coverage levels were 96%–100%. Regional differences existed as both WHO South-East Asia Region and WHO African Region countries experienced mean negative DTP3 coverage growth at lower coverage levels (81%–85%) than other regions. The regions that have achieved 95% DTP3 coverage (Americas, Western Pacific, and European) took 25–29 years to reach that level from a level of 50% DTP3 coverage. POL3 coverage change trends were similar to described DTP3 coverage change trends. Conclusions Mean national coverage growth patterns across all regions are nonlinear as coverage levels increase. Saturation points of mean 0 percentage-point growth in annual coverage varies by region and require further investigation. The achievement of >90% routine coverage is observed to take decades, which has implications for disease eradication and elimination initiatives. PMID:25316875
Wang, Dandan; Chen, Haifeng; Wang, Shiying; Zou, Yaohong; Li, Jing; Pan, Jieping; Wang, Xiangdang; Ren, Tianli; Zhang, Yu; Chen, Zhiwei; Feng, Xuebing; Sun, Lingyun
2016-06-01
Thalidomide is effective for treating severe cutaneous lupus patients. The aim of this study was to observe the optimum effective and maintenance doses of thalidomide to maximize clinical benefit and minimize side effects for patients with cutaneous lupus in China. Sixty-nine patients with lupus rash from eight hospitals in China were enrolled and treated with different doses of thalidomide. We started the dose of thalidomide at 25 mg daily and gradually increased administration dose once a week until erythema was markedly improved. The effective and maintenance doses were documented. The size of skin lesions was noted once a week. Systemic lupus erythematosus disease activity index (SLEDAI) score, levels of erythrocyte sedimentation rate (ESR), and serum TNF-α were measured before and after treatment. The remission rates were evaluated weekly until 8 weeks. Sixty-eight percent of patients showed an effective dose of 50 mg daily; another 13, 10, and 9 % of patients had an effective dose of 100, 75, and 25 mg daily, respectively. The maintenance dose was 50 mg daily for 71 % of the patients, and 100, 75, and 25 mg daily for 9, 14, and 6 % of the patients. SLEDAI score and serum ESR levels significantly decreased 4 weeks after thalidomide treatment. At the end of the fourth week, the rates of complete remission, partial remission, and no response were 56 % (n = 39), 41 % (n = 28), and 3 % (n = 2). At the eighth week, the rate of total remission rose up to 100 %. The most common side effects were drowsiness and constipation. No peripheral neuropathy was observed in these patients. Thalidomide at a dose of 50 mg daily may offer a better benefit to risk ratio in the treatment of Chinese cutaneous lupus patients.
Bradford, Ashley C; Bradford, W David; Abraham, Amanda; Bagwell Adams, Grace
2018-05-01
Opioid-related mortality increased by 15.6% from 2014 to 2015 and increased almost 320% between 2000 and 2015. Recent research finds that the use of all pain medications (opioid and nonopioid collectively) decreases in Medicare Part D and Medicaid populations when states approve medical cannabis laws (MCLs). The association between MCLs and opioid prescriptions is not well understood. To examine the association between prescribing patterns for opioids in Medicare Part D and the implementation of state MCLs. Longitudinal analysis of the daily doses of opioids filled in Medicare Part D for all opioids as a group and for categories of opioids by state and state-level MCLs from 2010 through 2015. Separate models were estimated first for whether the state had implemented any MCL and second for whether a state had implemented either a dispensary-based or a home cultivation only-based MCL. The primary outcome measure was the total number of daily opioid doses prescribed (in millions) in each US state for all opioids. The secondary analysis examined the association between MCLs separately by opioid class. From 2010 to 2015 there were 23.08 million daily doses of any opioid dispensed per year in the average state under Medicare Part D. Multiple regression analysis results found that patients filled fewer daily doses of any opioid in states with an MCL. The associations between MCLs and any opioid prescribing were statistically significant when we took the type of MCL into account: states with active dispensaries saw 3.742 million fewer daily doses filled (95% CI, -6.289 to -1.194); states with home cultivation only MCLs saw 1.792 million fewer filled daily doses (95% CI, -3.532 to -0.052). Results varied by type of opioid, with statistically significant estimated negative associations observed for hydrocodone and morphine. Hydrocodone use decreased by 2.320 million daily doses (or 17.4%) filled with dispensary-based MCLs (95% CI, -3.782 to -0.859; P = .002) and decreased by 1.256 million daily doses (or 9.4%) filled with home-cultivation-only-based MCLs (95% CI, -2.319 to -0.193; P = .02). Morphine use decreased by 0.361 million daily doses (or 20.7%) filled with dispensary-based MCLs (95% CI, -0.718 to -0.005; P = .047). Medical cannabis laws are associated with significant reductions in opioid prescribing in the Medicare Part D population. This finding was particularly strong in states that permit dispensaries, and for reductions in hydrocodone and morphine prescriptions.
Optimizing drug-dose alerts using commercial software throughout an integrated health care system.
Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C
2017-11-01
All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Maternal Tetanus Toxoid Vaccination and Neonatal Mortality in Rural North India
Singh, Abhishek; Pallikadavath, Saseendran; Ogollah, Reuben; Stones, William
2012-01-01
Objectives Preventable neonatal mortality due to tetanus infection remains common. We aimed to examine antenatal vaccination impact in a context of continuing high neonatal mortality in rural northern India. Methods and Findings Using the third round of the Indian National Family Health Survey (NFHS) 2005–06, mortality of most recent singleton births was analysed in discrete-time logistic model with maternal tetanus vaccination, together with antenatal care utilisation and supplementation with iron and folic acid. 59% of mothers reported receiving antenatal care, 48% reported receiving iron and folic acid supplementation and 68% reported receiving two or more doses of tetanus toxoid (TT) vaccination. The odds of all-cause neonatal death were reduced following one or more antenatal dose of TT with odds ratios (OR) of 0.46 (95% CI 0.26 to 0.78) after one dose and 0.45 (95% CI 0.31 to 0.66) after two or more doses. Reported utilisation of antenatal care and iron-folic acid supplementation did not influence neonatal mortality. In the statistical model, 16% (95% CI 5% to 27%) of neonatal deaths could be attributed to a lack of at least two doses of TT vaccination during pregnancy, representing an estimated 78,632 neonatal deaths in absolute terms. Conclusions Substantial gains in newborn survival could be achieved in rural North India through increased coverage of antenatal TT vaccination. The apparent substantial protective effect of a single antenatal dose of TT requires further study. It may reflect greater population vaccination coverage and indicates that health programming should prioritise universal antenatal coverage with at least one dose. PMID:23152814
Maternal tetanus toxoid vaccination and neonatal mortality in rural north India.
Singh, Abhishek; Pallikadavath, Saseendran; Ogollah, Reuben; Stones, William
2012-01-01
Preventable neonatal mortality due to tetanus infection remains common. We aimed to examine antenatal vaccination impact in a context of continuing high neonatal mortality in rural northern India. Using the third round of the Indian National Family Health Survey (NFHS) 2005-06, mortality of most recent singleton births was analysed in discrete-time logistic model with maternal tetanus vaccination, together with antenatal care utilisation and supplementation with iron and folic acid. 59% of mothers reported receiving antenatal care, 48% reported receiving iron and folic acid supplementation and 68% reported receiving two or more doses of tetanus toxoid (TT) vaccination. The odds of all-cause neonatal death were reduced following one or more antenatal dose of TT with odds ratios (OR) of 0.46 (95% CI 0.26 to 0.78) after one dose and 0.45 (95% CI 0.31 to 0.66) after two or more doses. Reported utilisation of antenatal care and iron-folic acid supplementation did not influence neonatal mortality. In the statistical model, 16% (95% CI 5% to 27%) of neonatal deaths could be attributed to a lack of at least two doses of TT vaccination during pregnancy, representing an estimated 78,632 neonatal deaths in absolute terms. Substantial gains in newborn survival could be achieved in rural North India through increased coverage of antenatal TT vaccination. The apparent substantial protective effect of a single antenatal dose of TT requires further study. It may reflect greater population vaccination coverage and indicates that health programming should prioritise universal antenatal coverage with at least one dose.
Madan, Renu; Pathy, Sushmita; Subramani, Vellaiyan; Sharma, Seema; Mohanti, Bidhu Kalyan; Chander, Subhash; Thulkar, Sanjay; Kumar, Lalit; Dadhwal, Vatsla
2014-01-01
Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned . All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Mean doses received by 100% and 90% of the target volume were 4.24 ± 0.63 and 4.9 ± 0.56 Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were 2.88 ± 0.72, 2.5 ± 0.65 and 2.2 ± 0.57 times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were 1.80 ± 0.5, 1.48 ± 0.41 and 1.35 ± 0.37 times higher than ICRU rectal reference point. Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.
State of equity: childhood immunization in the World Health Organization African Region
Casey, Rebecca Mary; Hampton, Lee McCalla; Anya, Blanche-philomene Melanga; Gacic-Dobo, Marta; Diallo, Mamadou Saliou; Wallace, Aaron Stuart
2017-01-01
Introduction In 2010, the Global Vaccine Action Plan called on all countries to reach and sustain 90% national coverage and 80% coverage in all districts for the third dose of diphtheria-tetanus-pertussis vaccine (DTP3) by 2015 and for all vaccines in national immunization schedules by 2020. The aims of this study are to analyze recent trends in national vaccination coverage in the World Health Organization African Region andto assess how these trends differ by country income category. Methods We compared national vaccination coverage estimates for DTP3 and the first dose of measles-containing vaccine (MCV) obtained from the World Health Organization (WHO)/United Nations Children’s Fund (UNICEF) joint estimates of national immunization coverage for all African Region countries. Using United Nations (UN) population estimates of surviving infants and country income category for the corresponding year, we calculated population-weighted average vaccination coverage by country income category (i.e., low, lower middle, and upper middle-income) for the years 2000, 2005, 2010 and 2015. Results DTP3 coverage in the African Region increased from 52% in 2000 to 76% in 2015,and MCV1 coverage increased from 53% to 74% during the same period, but with considerable differences among countries. Thirty-six African Region countries were low income in 2000 with an average DTP3 coverage of 50% while 26 were low income in 2015 with an average coverage of 80%. Five countries were lower middle-income in 2000 with an average DTP3 coverage of 84% while 12 were lower middle-income in 2015 with an average coverage of 69%. Five countries were upper middle-income in 2000 with an average DTP3 coverage of 73% and eight were upper middle-income in 2015 with an average coverage of 76%. Conclusion Disparities in vaccination coverage by country persist in the African Region, with countries that were lower middle-income having the lowest coverage on average in 2015. Monitoring and addressing these disparities is essential for meeting global immunization targets. PMID:29296140
Valeri, Fabio; Hatz, Christoph; Jordan, Dominique; Leuthold, Claudine; Czock, Astrid; Lang, Phung
2014-01-01
To assess vaccination coverage for adults living in Switzerland. Through a media campaign, the general population was invited during 1 month to bring their vaccination certificates to the pharmacies to have their immunisation status evaluated with the software viavac©, and to complete a questionnaire. A total of 496 pharmacies in Switzerland participated in the campaign, of which 284 (57%) submitted valid vaccination information. From a total of 3,634 participants in the campaign, there were 3,291 valid cases (participants born ≤ 1992) and 1,011 questionnaires completed. Vaccination coverage for the participants was 45.9% and 34.6% for five and six doses of diphtheria, 56.4% and 44.0% for tetanus and 66.3% and 48.0% for polio, respectively. Coverage estimates for one and two doses of measles vaccine were 76.5% and 49.4%, respectively, for the birth cohort 1967-1992 and 4.0% and 0.8%, respectively, for the cohort ≤ 1966. There was a significant difference in coverage for most vaccinations between the two aforementioned birth cohorts. A plot of the measles vaccine coverage over time shows that the increase in coverage correlated with policy changes in the Swiss Immunisation Schedule. Despite selection bias and low participation, this study indicates that vaccination coverage for the basic recommended immunisations in the adult population in Switzerland is suboptimal. More efforts using various means and methods are needed to increase immunisation coverage in adolescents before they leave school. An established method to determine vaccination coverage for the general population could provide invaluable insights into the effects of changes in vaccination policies and disease outbreaks.
Increased immunization coverage addresses the equity gap in Nepal
Nelin, Viktoria; Raaijmakers, Hendrikus; Kim, Hyung Joon; Singh, Chahana; Målqvist, Mats
2017-01-01
Abstract Objective To compare immunization coverage and equity distribution of coverage between 2001 and 2014 in Nepal. Methods We used data from the Demographic and Health Surveys carried out in 2001, 2006 and 2011 together with data from the 2014 Multiple Indicator Cluster Survey. We calculated the proportion, in mean percentage, of children who had received bacille Calmette–Guérin (BCG) vaccine, three doses of polio vaccine, three doses of diphtheria–pertussis–tetanus (DPT) vaccine and measles vaccine. To measure inequities between wealth quintiles, we calculated the slope index of inequality (SII) and relative index of inequality (RII) for all surveys. Findings From 2001 to 2014, the proportion of children who received all vaccines at the age of 12 months increased from 68.8% (95% confidence interval, CI: 67.5–70.1) to 82.4% (95% CI: 80.7–84.0). While coverage of BCG, DPT and measles immunization statistically increased during the study period, the proportion of children who received the third dose of polio vaccine decreased from 93.3% (95% CI: 92.7–93.9) to 88.1% (95% CI: 86.8–89.3). The poorest wealth quintile showed the greatest improvement in immunization coverage, from 58% to 77.9%, while the wealthiest quintile only improved from 84.8% to 86.0%. The SII for children who received all vaccines improved from 0.070 (95% CI: 0.061–0.078) to 0.026 (95% CI: 0.013–0.039) and RII improved from 1.13 to 1.03. Conclusion The improvement in immunization coverage between 2001 and 2014 in Nepal can mainly be attributed to the interventions targeting the disadvantaged populations. PMID:28479621
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quirk, S; Conroy, L; Smith, WL
Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20more » mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.« less
CBCT-guided evolutive library for cervical adaptive IMRT.
Rigaud, Bastien; Simon, Antoine; Gobeli, Maxime; Lafond, Caroline; Leseur, Julie; Barateau, Anais; Jaksic, Nicolas; Castelli, Joël; Williaume, Danièle; Haigron, Pascal; De Crevoisier, Renaud
2018-04-01
In the context of adaptive radiation therapy (ART) for locally advanced cervical carcinoma (LACC), this study proposed an original cone-beam computed tomography (CBCT)-guided "Evolutive library" and evaluated it against four other known radiotherapy (RT) strategies. For 20 patients who underwent intensity-modulated radiation therapy (IMRT) for LACC, three planning CTs [with empty (EB), intermediate (IB), and full (FB) bladder volumes], a CT scan at 20 Gy and bi-weekly CBCTs for 5 weeks were performed. Five RT strategies were simulated for each patient: "Standard RT" was based on one IB planning CT; "internal target volume (ITV)-based RT" was an ITV built from the three planning CTs; "RT with one mid-treatment replanning (MidTtReplan)" corresponded to the standard RT with a replanning at 20 Gy; "Pretreatment library ART" using a planning library based on the three planning CTs; and the "Evolutive library ART", which was the "Pretreatment library ART" strategy enriched by including some CBCT anatomies into the library when the daily clinical target volume (CTV) shape differed from the ones in the library. Two planning target volume (PTV) margins of 7 and 10 mm were evaluated. All the strategies were geometrically compared in terms of the percentage of coverage by the PTV, for the CTV and the organs at risk (OAR) delineated on the CBCT. Inadequate coverage of the CTV and OARs by the PTV was also assessed using deformable image registration. The cumulated dose distributions of each strategy were likewise estimated and compared for one patient. The "Evolutive library ART" strategy involved a number of added CBCTs: 0 for 55%; 1 for 30%; 2 for 5%; and 3 for 10% of patients. Compared with the other four, this strategy provided the highest CTV geometric coverage by the PTV, with a mean (min-max) coverage of 98.5% (96.4-100) for 10 mm margins and 96.2% (93.0-99.7) for 7 mm margins (P < 0.05). Moreover, this strategy significantly decreased the geometric coverage of the bowel. CTV undercoverage by PTV occurred in the anterior and superior uterine regions for all strategies. The dosimetric analysis at 7 mm similarly demonstrated that the "Evolutive library ART" increased the V 42.75Gy of the CTV by 27%, 20%, 13%, and 28% compared with "Standard RT", "ITV-based RT", "MidTtReplan", and "Pretreatment library ART", respectively. The dose to the bowel was also decreased by the "Evolutive library ART" compared with that by the other strategies. The "Evolutive library ART" is a personalized ART strategy that comprises a pretreatment planning library of three CT scans, enriched for half of the patients by one to three per-treatment CBCTs. This original strategy increased both the CTV coverage and bowel sparing compared with all the other tested strategies and enables us to consider a PTV margin reduction. © 2018 American Association of Physicists in Medicine.
Heaton, Alexis; Krudwig, Kirstin; Lorenson, Tina; Burgess, Craig; Cunningham, Andrew; Steinglass, Robert
2017-04-19
The widespread use of multidose vaccine containers in low and middle income countries' immunization programs is assumed to have multiple benefits and efficiencies for health systems, yet the broader impacts on immunization coverage, costs, and safety are not well understood. To document what is known on this topic, how it has been studied, and confirm the gaps in evidence that allow us to assess the complex system interactions, the authors undertook a review of published literature that explored the relationship between doses per container and immunization systems. The relationships examined in this study are organized within a systems framework consisting of operational costs, timely coverage, safety, product costs/wastage, and policy/correct use, with the idea that a change in dose per container affects all of them, and the optimal solution will depend on what is prioritized and used to measure performance. Studies on this topic are limited and largely rely on modeling to assess the relationship between doses per container and other aspects of immunization systems. Very few studies attempt to look at how a change in doses per container affects vaccination coverage rates and other systems components simultaneously. This article summarizes the published knowledge on this topic to date and suggests areas of current and future research to ultimately improve decision making around vaccine doses per container and increase understanding of how this decision relates to other program goals. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
A decade of Australian methotrexate dosing errors.
Cairns, Rose; Brown, Jared A; Lynch, Ann-Maree; Robinson, Jeff; Wylie, Carol; Buckley, Nicholas A
2016-06-06
Accidental daily dosing of methotrexate can result in life-threatening toxicity. We investigated methotrexate dosing errors reported to the National Coronial Information System (NCIS), the Therapeutic Goods Administration Database of Adverse Event Notifications (TGA DAEN) and Australian Poisons Information Centres (PICs). A retrospective review of coronial cases in the NCIS (2000-2014), and of reports to the TGA DAEN (2004-2014) and Australian PICs (2004-2015). Cases were included if dosing errors were accidental, with evidence of daily dosing on at least 3 consecutive days. Events per year, dose, consecutive days of methotrexate administration, reasons for the error, clinical features. Twenty-two deaths linked with methotrexate were identified in the NCIS, including seven cases in which erroneous daily dosing was documented. Methotrexate medication error was listed in ten cases in the DAEN, including two deaths. Australian PIC databases contained 92 cases, with a worrying increase seen during 2014-2015. Reasons for the errors included patient misunderstanding and incorrect packaging of dosette packs by pharmacists. The recorded clinical effects of daily dosage were consistent with those previously reported for methotrexate toxicity. Dosing errors with methotrexate can be lethal and continue to occur despite a number of safety initiatives in the past decade. Further strategies to reduce these preventable harms need to be implemented and evaluated. Recent suggestions include further changes in packet size, mandatory weekly dosing labelling on packaging, improving education, and including alerts in prescribing and dispensing software.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin Zhixiong; Mechalakos, James; Nehmeh, Sadek
2008-03-15
Purpose: To evaluate how changes in tumor hypoxia, according to serial fluorine-18-labeled fluoro-misonidazole ({sup 18}F-FMISO) positron emission tomography (PET) imaging, affect the efficacy of intensity-modulated radiotherapy (IMRT) dose painting. Methods and Materials: Seven patients with head and neck cancers were imaged twice with FMISO PET, separated by 3 days, before radiotherapy. Intensity-modulated radiotherapy plans were designed, on the basis of the first FMISO scan, to deliver a boost dose of 14 Gy to the hypoxic volume, in addition to the 70-Gy prescription dose. The same plans were then applied to hypoxic volumes from the second FMISO scan, and the efficacymore » of dose painting evaluated by assessing coverage of the hypoxic volumes using D{sub max}, D{sub min}, D{sub mean}, D{sub 95}, and equivalent uniform dose (EUD). Results: Similar hypoxic volumes were observed in the serial scans for 3 patients but dissimilar ones for the other 4. There was reduced coverage of hypoxic volumes of the second FMISO scan relative to that of the first scan (e.g., the average EUD decreased from 87 Gy to 80 Gy). The decrease was dependent on the similarity of the hypoxic volumes of the two scans (e.g., the average EUD decrease was approximately 4 Gy for patients with similar hypoxic volumes and approximately 12 Gy for patients with dissimilar ones). Conclusions: The changes in spatial distribution of tumor hypoxia, as detected in serial FMISO PET imaging, compromised the coverage of hypoxic tumor volumes achievable by dose-painting IMRT. However, dose painting always increased the EUD of the hypoxic volumes.« less
Kharbanda, Elyse Olshen; Parker, Emily; Nordin, James D; Hedblom, Brita; Rolnick, Sharon J
2013-11-01
To describe human papillomavirus (HPV) vaccine coverage among adult privately insured women including variation in coverage by race/ethnicity. This cross-sectional, observational study included women 18-26 years of age with continuous enrollment in a U.S. Midwestern health insurance plan and at least one visit to a plan affiliated practice. Vaccination data came from insurance claims and the electronic medical record. Primary outcomes were: receipt of at least 1 HPV vaccine (HPV1) and completion of the 3-dose HPV vaccine series (HPV3). Coverage was described for the entire cohort and stratified by race/ethnicity. For a subset of women, automated data was compared to personal recall. As of June 2010, among 2546 privately insured women 18-26 years, 72.7% had received their first HPV vaccine and 57.9% completed the 3-dose series. Compared to white women, African American and Asian women had significantly lower coverage for HPV1 and HPV3. There was 94.5% (95% CI: 88.5-100%) agreement between personal recall and claims/EMR for receiving HPV1. In this cohort of privately insured women, a majority received HPV1 and more than half completed the 3-dose vaccine series. Marked disparities in receipt of HPV vaccine by race/ethnicity were observed. © 2013.
Evaluating which plan quality metrics are appropriate for use in lung SBRT.
Yaparpalvi, Ravindra; Garg, Madhur K; Shen, Jin; Bodner, William R; Mynampati, Dinesh K; Gafar, Aleiya; Kuo, Hsiang-Chi; Basavatia, Amar K; Ohri, Nitin; Hong, Linda X; Kalnicki, Shalom; Tome, Wolfgang A
2018-02-01
Several dose metrics in the categories-homogeneity, coverage, conformity and gradient have been proposed in literature for evaluating treatment plan quality. In this study, we applied these metrics to characterize and identify the plan quality metrics that would merit plan quality assessment in lung stereotactic body radiation therapy (SBRT) dose distributions. Treatment plans of 90 lung SBRT patients, comprising 91 targets, treated in our institution were retrospectively reviewed. Dose calculations were performed using anisotropic analytical algorithm (AAA) with heterogeneity correction. A literature review on published plan quality metrics in the categories-coverage, homogeneity, conformity and gradient was performed. For each patient, using dose-volume histogram data, plan quality metric values were quantified and analysed. For the study, the radiation therapy oncology group (RTOG) defined plan quality metrics were: coverage (0.90 ± 0.08); homogeneity (1.27 ± 0.07); conformity (1.03 ± 0.07) and gradient (4.40 ± 0.80). Geometric conformity strongly correlated with conformity index (p < 0.0001). Gradient measures strongly correlated with target volume (p < 0.0001). The RTOG lung SBRT protocol advocated conformity guidelines for prescribed dose in all categories were met in ≥94% of cases. The proportion of total lung volume receiving doses of 20 Gy and 5 Gy (V 20 and V 5 ) were mean 4.8% (±3.2) and 16.4% (±9.2), respectively. Based on our study analyses, we recommend the following metrics as appropriate surrogates for establishing SBRT lung plan quality guidelines-coverage % (ICRU 62), conformity (CN or CI Paddick ) and gradient (R 50% ). Furthermore, we strongly recommend that RTOG lung SBRT protocols adopt either CN or CI Padddick in place of prescription isodose to target volume ratio for conformity index evaluation. Advances in knowledge: Our study metrics are valuable tools for establishing lung SBRT plan quality guidelines.
Deveau, Michael A; Gutiérrez, Alonso N; Mackie, Thomas R; Tomé, Wolfgang A; Forrest, Lisa J
2010-01-01
Intensity-modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction-by-fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5 mm (0-10.0 mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9 +/- 3.3 mm. Due to variations, a loss of equivalent uniform dose for target volumes of up to 5.6% was noted which corresponded to a potential loss in tumor control probability of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose and highest normalized dose given to 2% of the volume. Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non-rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and/or radiation toxicities to the eyes and brain.
Deveau, Michael A.; Gutiérrez, Alonso N.; Mackie, Thomas R.; Tomé, Wolfgang A.; Forrest, Lisa J.
2009-01-01
Intensity-modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction-by-fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5mm (0-10.0mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9±3.3mm. Due to variations, a loss of equivalent uniform dose (EUD) for target volumes of up to 5.6% was noted which corresponded to a potential loss in TCP of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose (NTDmean) and highest normalized dose given to 2% of the volume (NTD2%). Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non-rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and/or radiation toxicities to the eyes and brain. PMID:20166402
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk; Mohamad, Issa; Dayyat, Abdulmajeed
2015-10-01
Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dosemore » and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p < 0.001). As expected, photon-only plans demonstrated the highest target coverage and total lung V{sub 20} {sub Gy}. The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots associated with such plans. Combined photon-electron treatment is a feasible technique for supraclavicular nodal irradiation and results in adequate target coverage, acceptable dosimetric hotspot volume, and slightly reduced lung dose.« less
Dose comparisons of clopidogrel and aspirin in acute coronary syndromes.
Mehta, Shamir R; Bassand, Jean-Pierre; Chrolavicius, Susan; Diaz, Rafael; Eikelboom, John W; Fox, Keith A A; Granger, Christopher B; Jolly, Sanjit; Joyner, Campbell D; Rupprecht, Hans-Jurgen; Widimsky, Petr; Afzal, Rizwan; Pogue, Janice; Yusuf, Salim
2010-09-02
Clopidogrel and aspirin are widely used for patients with acute coronary syndromes and those undergoing percutaneous coronary intervention (PCI). However, evidence-based guidelines for dosing have not been established for either agent. We randomly assigned, in a 2-by-2 factorial design, 25,086 patients with an acute coronary syndrome who were referred for an invasive strategy to either double-dose clopidogrel (a 600-mg loading dose on day 1, followed by 150 mg daily for 6 days and 75 mg daily thereafter) or standard-dose clopidogrel (a 300-mg loading dose and 75 mg daily thereafter) and either higher-dose aspirin (300 to 325 mg daily) or lower-dose aspirin (75 to 100 mg daily). The primary outcome was cardiovascular death, myocardial infarction, or stroke at 30 days. The primary outcome occurred in 4.2% of patients assigned to double-dose clopidogrel as compared with 4.4% assigned to standard-dose clopidogrel (hazard ratio, 0.94; 95% confidence interval [CI], 0.83 to 1.06; P=0.30). Major bleeding occurred in 2.5% of patients in the double-dose group and in 2.0% in the standard-dose group (hazard ratio, 1.24; 95% CI, 1.05 to 1.46; P=0.01). Double-dose clopidogrel was associated with a significant reduction in the secondary outcome of stent thrombosis among the 17,263 patients who underwent PCI (1.6% vs. 2.3%; hazard ratio, 0.68; 95% CI, 0.55 to 0.85; P=0.001). There was no significant difference between higher-dose and lower-dose aspirin with respect to the primary outcome (4.2% vs. 4.4%; hazard ratio, 0.97; 95% CI, 0.86 to 1.09; P=0.61) or major bleeding (2.3% vs. 2.3%; hazard ratio, 0.99; 95% CI, 0.84 to 1.17; P=0.90). In patients with an acute coronary syndrome who were referred for an invasive strategy, there was no significant difference between a 7-day, double-dose clopidogrel regimen and the standard-dose regimen, or between higher-dose aspirin and lower-dose aspirin, with respect to the primary outcome of cardiovascular death, myocardial infarction, or stroke. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00335452.)
Influence of intravenous opioid dose on postoperative ileus.
Barletta, Jeffrey F; Asgeirsson, Theodor; Senagore, Anthony J
2011-07-01
Intravenous opioids represent a major component in the pathophysiology of postoperative ileus (POI). However, the most appropriate measure and threshold to quantify the association between opioid dose (eg, average daily, cumulative, maximum daily) and POI remains unknown. To evaluate the relationship between opioid dose, POI, and length of stay (LOS) and identify the opioid measure that was most strongly associated with POI. Consecutive patients admitted to a community teaching hospital who underwent elective colorectal surgery by any technique with an enhanced-recovery protocol postoperatively were retrospectively identified. Patients were excluded if they received epidural analgesia, developed a major intraabdominal complication or medical complication, or had a prolonged workup prior to surgery. Intravenous opioid doses were quantified and converted to hydromorphone equivalents. Classification and regression tree (CART) analysis was used to determine the dosing threshold for the opioid measure most associated with POI and define high versus low use of opioids. Risk factors for POI and prolonged LOS were determined through multivariate analysis. The incidence of POI in 279 patients was 8.6%. CART analysis identified a maximum daily intravenous hydromorphone dose of 2 mg or more as the opioid measure most associated with POI. Multivariate analysis revealed maximum daily hydromorphone dose of 2 mg or more (p = 0.034), open surgical technique (p = 0.045), and days of intravenous narcotic therapy (p = 0.003) as significant risk factors for POI. Variables associated with increased LOS were POI (p < 0.001), maximum daily hydromorphone dose of 2 mg or more (p < 0.001), and age (p = 0.005); laparoscopy (p < 0.001) was associated with a decreased LOS. Intravenous opioid therapy is significantly associated with POI and prolonged LOS, particularly when the maximum hydromorphone dose per day exceeds 2 mg. Clinicians should consider alternative, nonopioid-based pain management options when this occurs.
Narula, Neeraj; Cooray, Mohan; Anglin, Rebecca; Muqtadir, Zack; Narula, Alisha; Marshall, John K
2017-02-01
To assess the tolerability and efficacy of high-dose vitamin D3 in patients with Crohn's disease (CD). This was a randomized, double-blind placebo-controlled trial of high-dose vitamin D3 at 10,000 IU daily (n = 18) compared to 1000 IU daily (n = 16) for 12 months in patients with CD in remission. The primary outcome was change in serum 25-hydroxy-vitamin D levels. Secondary outcomes included clinical relapse rates and changes in mood scores. High-dose vitamin D3 at 10,000 IU daily significantly improved 25-hydroxy-vitamin D levels from a mean of 73.5 nmol/L [standard deviation (SD) 11.7 nmol/L] to 160.8 nmol/L (SD 43.2 nmol/L) (p = 0.02). On an intention-to-treat basis, the rate of relapse was not significantly different between patients receiving low- and high-dose vitamin D3 (68.8 vs 33.3%, p = 0.0844). In per-protocol analysis, clinical relapse of Crohn's disease was less frequently observed in patients receiving a high dose (0/12 or 0%) compared to those receiving a low dose of 1000 IU daily (3/8 or 37.5%) (p = 0.049). Improvement in anxiety and depression scores and a good safety profile were observed in both groups treated with vitamin D3. Oral supplementation with high-dose vitamin D3 at 10,000 IU daily significantly improved serum 25-hydroxy-vitamin D levels. Rates of clinical relapse were similar between both groups. Larger studies using high-dose vitamin D3 for treatment of inflammatory bowel diseases are warranted. CLINICALTRIALS. NCT02615288.
Dosimetrically Triggered Adaptive Intensity Modulated Radiation Therapy for Cervical Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Karen; Stewart, James; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario
2014-09-01
Purpose: The widespread use of intensity modulated radiation therapy (IMRT) for cervical cancer has been limited by internal target and normal tissue motion. Such motion increases the risk of underdosing the target, especially as planning margins are reduced in an effort to reduce toxicity. This study explored 2 adaptive strategies to mitigate this risk and proposes a new, automated method that minimizes replanning workload. Methods and Materials: Thirty patients with cervical cancer participated in a prospective clinical study and underwent pretreatment and weekly magnetic resonance (MR) scans over a 5-week course of daily external beam radiation therapy. Target volumes andmore » organs at risk (OARs) were contoured on each of the scans. Deformable image registration was used to model the accumulated dose (the real dose delivered to the target and OARs) for 2 adaptive replanning scenarios that assumed a very small PTV margin of only 3 mm to account for setup and internal interfractional motion: (1) a preprogrammed, anatomy-driven midtreatment replan (A-IMRT); and (2) a dosimetry-triggered replan driven by target dose accumulation over time (D-IMRT). Results: Across all 30 patients, clinically relevant target dose thresholds failed for 8 patients (27%) if 3-mm margins were used without replanning. A-IMRT failed in only 3 patients and also yielded an additional small reduction in OAR doses at the cost of 30 replans. D-IMRT assured adequate target coverage in all patients, with only 23 replans in 16 patients. Conclusions: A novel, dosimetry-triggered adaptive IMRT strategy for patients with cervical cancer can minimize the risk of target underdosing in the setting of very small margins and substantial interfractional motion while minimizing programmatic workload and cost.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zare, Mahkameh; Lashkari, Marzieh, E-mail: m-lashkari@sina.tums.ac.ir; Ghalehtaki, Reza
2016-01-01
External radiotherapy is a standard treatment procedure for localized prostate cancer. Given the relatively high long term survival treatment complications have been brought in center of attention. In this planning study, between 2012 and 2014, CT simulation data of 90 consecutive high-risk prostate cancer patients were collected. In the first phase, all were planned for whole pelvis irradiation up to 46Gy in 23 daily fractions. In the second phase, only the prostate gland was the target of radiation. Next, the subjects were divided randomly into three groups and each received a unique 5field conformal radiation plan including Plan A (Gantrymore » angle: 0, 60, 120, 240, and 300), Plan B (Gantry angles: 0, 90, 120, 240, and 270) and Plan C (Gantry angles: 0, 60, 90, 270, and 300). The total dose was 70Gy. For each patient, the rectum, bladder, and both femoral heads were contoured as the at risk organs (OAR). From dose volume histograms, the proportional dose of PTV V100, the bladder and rectum V80 and V90 and femoral head V50 and V100 were calculated in all subjects and compared across plans. A statistically significant difference in the femoral head V50 and V100 was found between our studied 5field plans so that in Plan A (beam angles: 0, 60, 120, 240 and 300) less dose was received by both heads of femur. This study suggests that 5 field treatment planning including an anterior, two anterior oblique and two posterior oblique portals to be more proper for 3D conformal radiotherapy in order to spare femoral head with acceptable PTV coverage, and bladder and rectal doses.« less
The effectiveness of reducing the daily dose of finasteride in men with benign prostatic hyperplasia
Sullivan, Michael J; Geller, Jack
2002-01-01
Background Finasteride, a 5 alpha reductase inhibitor, is an established treatment for benign prostatic hyperplasia. The recommended dosage is 5 mg a day, however case reports have show effectiveness with lower doses. The objective of the current study was to determine in men with benign prostatic hyperplasia, previously treated for at least one year with finasteride 5 mg daily, if they will maintain subjective and objective improvements in urinary obstruction when treated with 2.5 mg of finasteride daily for one year. Methods In an open label, prospective study, 40 men with benign prostatic hyperplasia, previously treated for at least one year with 5 mg of finasteride, took 2.5 mg of finasteride daily for one year. Measurements included AUA symptom score, maximum flow rate, voided volume and PSA. Results There were no significant changes in maximum flow rate, voided volume, or AUA symptom score after one year of finasteride 2.5 mg daily therapy. PSA increased significantly, p < .01, after one year of finasteride 2.5 mg daily, 2.0 +1.4 ng/ml, when compared to finasteride 5 mg daily, 1.4+ 1.0 ng/ml. Conclusions The daily dose of finasteride can be reduced to 2.5 mg daily without significant effect on subjective and objective measures of urinary obstruction. Although statistically significant increases in PSA are noted when reducing the daily finasteride dose from 5 mg to 2.5 mg, the clinical significance of a mean .6 ng/ml increase in PSA is questionable. PMID:11818031
Sharma, M; Sy, S; Kim, J J
2016-05-01
To estimate health benefits and incremental cost-effectiveness of human papillomavirus (HPV) vaccination of pre-adolescent boys and girls compared with girls alone for preventing cervical cancer and genital warts. Model-based economic evaluation. Southern Vietnam. Males and females aged ≥9 years. We simulated dynamic HPV transmission to estimate cervical cancer and genital warts cases. Models were calibrated to epidemiological data from south Vietnam. Incremental cost-effectiveness ratios (ICERs): cost per quality-adjusted life-year (QALY). Vaccinating girls alone was associated with reductions in lifetime cervical cancer risk ranging from 20 to 56.9% as coverage varied from 25 to 90%. Adding boys to the vaccination programme yielded marginal incremental benefits (≤3.6% higher absolute cervical cancer risk reduction), compared with vaccinating girls alone at all coverages. At ≤25 international dollars (I$) per vaccinated adolescent (I$5 per dose), HPV vaccination of boys was below the threshold of Vietnam's per-capita GDP (I$2800), with ICERs ranging from I$734 per QALY at 25% coverage to I$2064 per QALY for 90% coverage. Including health benefits from averting genital warts yielded more favourable ICERs, and vaccination of boys at I$10/dose became cost-effective at or below 75% coverage. Using a lower cost-effectiveness threshold of 50% of Vietnam's GDP (I$1400), vaccinating boys was no longer attractive at costs above I$5 per dose regardless of coverage. Vaccination of boys may be cost-effective at low vaccine costs, but provides little benefit over vaccinating girls only. Focusing on achieving high vaccine coverage of girls may be more efficient for southern Vietnam and similar low-resource settings. Limited cervical cancer reduction from including boys in HPV vaccination of girls in low-resource settings. © 2015 Royal College of Obstetricians and Gynaecologists.
Levitt, M J; Kann, J
1984-07-01
This randomized crossover study compared the pharmacokinetics of choline magnesium trisalicylate tablets administered once daily (3000 mg of salicylate) or twice daily (1500 mg of salicylate) for six d. Serum salicylate levels were measured by HPLC. Mean "trough" concentrations fell within the therapeutic range (5-30 mg/dL) with either regimen and were relatively constant, indicating that the steady state had been reached. The 24-h area under the salicylate curve (AUC0-24 h) after the final 3000-mg salicylate dose averaged about twice the mean 12-h AUC after the last 1500-mg dose, indicating that the two dosing regimens were equally bioavailable. Clinical observations and results of laboratory safety studies indicate that both dosage schedules of the drug are well tolerated. The present findings support the once-daily therapeutic use of choline magnesium trisalicylate.
Fosnocht, D; Taylor, J R; Caravati, E M
2008-04-01
This study was designed to evaluate patient knowledge of the acetaminophen (paracetamol) content of commonly used pain medications and the maximum daily recommended dose of acetaminophen. A prospective, convenience sample of emergency department patients were enrolled. Data were recorded using a standardised questionnaire over 4 months. 1009 patients were enrolled. 492 patients (49%) did not know if Tylenol contained acetaminophen (paracetamol). The majority (66-90%) of patients did not know if Lortab, Vicodin, Percocet, non-aspirin pain reliever, ibuprofen, Motrin, or Advil contained acetaminophen. 568 patients (56%) reported not knowing the maximum daily dose of acetaminophen and only 71 patients (7%) reported the correct daily dose. Patient knowledge of the acetaminophen content of commonly used analgesic medications and its maximum recommended daily dose is limited. This may contribute to unintentional repeated supratherapeutic ingestion (RSTI) of acetaminophen, or overdose.
Nguyen, S; Robineau, O; Titecat, M; Blondiaux, N; Valette, M; Loiez, C; Beltrand, E; Migaud, H; Senneville, E
2015-08-01
Data on the tolerance and effectiveness of rifampicin-levofloxacin combination therapy (RLCT) in patients treated for prosthetic joint infections (PJIs) according to daily dosage are lacking. A review of the clinical data from patients treated with RLCT for PJIs in a French referent center for PJIs was conducted. A total of 154 patients (75 F/79 M), with a median age of 64.1 years and median body weight of 83.1 kg, were included. The median daily dosages of rifampicin and levofloxacin were, respectively, 1,200 mg (range 300-2,100) and 750 mg (range 500-1,500), corresponding to a mean daily dose per kg of, respectively, 16.2 ± 4.3 mg/kg and 10.1 ± 3.0 mg/kg. After a mean follow-up period of 55.6 ± 27.1 months (range 24-236), 127 patients (82.5 %) were in remission. Adverse events attributable to rifampicin and levofloxacin were reported in 48 (31.2 %) and 13 (8.4 %) patients (p < 0.001), respectively. Patients who experienced rifampicin-related adverse events had been given higher rifampicin daily doses than the other patients (p = 0.04). The rifampicin daily dosage did not influence patient outcome and nor did the levofloxacin daily dosage on both tolerance and patient outcome. Our results suggest that adjusting rifampicin daily doses to the patient total body weight when combined with levofloxacin for the treatment of PJIs is associated with a poor tolerance. High daily doses of rifampicin (>600 mg) and levofloxacin (750 mg) do not improve patient outcome when compared to lower daily doses in this setting.
Changes in Coverage of Sun Protection in the News: Threats and Opportunities from Emerging Issues
ERIC Educational Resources Information Center
Scully, Maree; Makin, Jennifer; Maloney, Sarah; Wakefield, Melanie
2014-01-01
This study aimed to determine whether there have been shifts in news coverage of sun protection issues over a 12-year period in the context of an evolving skin cancer prevention agenda. A content analysis was performed on all relevant articles (N = 552) published in the two metropolitan daily newspapers in Melbourne, Australia, from 2001 to 2012.…
Ahmed, Irfan; DeMarco, Marylou; Stevens, Craig W; Fulp, William J; Dilling, Thomas J
2011-01-01
Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI(off)) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI(on)). Nodal stations were contoured using published guidelines, then placed into 4 "bins" (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI(on) plans demonstrated a statistically significant degradation in dose coverage compared with the ENI(off) plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the "1 echelon away" nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes within the mediastinum. The ENI(on) plans demonstrate that intergroup-style treatments, as actually delivered, had statistically reduced coverage to the mediastinum and tumor volumes than was reported. Furthermore, SNI leads to improved tumor coverage and reduced esophageal/spinal cord dose, which suggests the possibility of dose escalation using SNI. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Stevens, Robin; Hull, Shawnika J
Although overall HIV rates have declined in the U.S. over the past two decades, these declines have been accompanied by steady growth in infection rates among African Americans, creating persistent racial disparities in HIV infection. News media have been instrumental in educating and informing the public about the epidemic. This content analytic study examines the frequency and content of coverage of HIV/AIDS in national and local U.S. daily newspapers from December 1992 through December 2007 with a focus on the presentation of risk by population subgroups. A computerized search term was used to identify HIV/AIDS-related news coverage from 24 daily U.S. newspapers and one wire service across a 15-year period (N = 53,934 stories). Human and computerized coding methods were used to examine patterns in frequency and content in the sample. Results indicate a decline in coverage of the epidemic over the study period. There was also a marked shift in the portrayal of risk in the U.S., from a domestic to an international focus. When coverage did address HIV/AIDS among groups with disproportionately high risk in the U.S., it typically failed to provide context for the disparity beyond individual behavioral risk factors. The meta-message of news coverage of HIV during this period may have reduced the visibility of the impact of HIV/AIDS on Americans. The practice of reporting the racial disparity without providing context may have consequences for the general public's ability to interpret these disparities.
The Color of AIDS: An Analysis of newspaper coverage of HIV/AIDS in the United States from 1992–2007
Stevens, Robin; Hull, Shawnika J.
2015-01-01
Although overall HIV rates have declined in the U.S. over the past two decades, these declines have been accompanied by steady growth in infection rates among African Americans, creating persistent racial disparities in HIV infection. News media have been instrumental in educating and informing the public about the epidemic. This content analytic study examines the frequency and content of coverage of HIV/AIDS in national and local U.S. daily newspapers from December 1992 through December 2007 with a focus on the presentation of risk by population subgroups. A computerized search term was used to identify HIV/AIDS-related news coverage from 24 daily U.S. newspapers and one wire service across a 15-year period (N = 53,934 stories). Human and computerized coding methods were used to examine patterns in frequency and content in the sample. Results indicate a decline in coverage of the epidemic over the study period. There was also a marked shift in the portrayal of risk in the U.S., from a domestic to an international focus. When coverage did address HIV/AIDS among groups with disproportionately high risk in the U.S., it typically failed to provide context for the disparity beyond individual behavioral risk factors. The meta-message of news coverage of HIV during this period may have reduced the visibility of the impact of HIV/AIDS on Americans. The practice of reporting the racial disparity without providing context may have consequences for the general public’s ability to interpret these disparities. PMID:26586923
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, M; Yu, N; Joshi, N
Purpose: To dosimetrically evaluate the importance of timely reviewing daily CBCTs for patients with head and neck cancer. Methods: After each fraction daily cone-beam CT (CBCT) for head and neck patients are reviewed by physicians prior to next treatment. Physician rejected image registrations of CBCT were identified and analyzed for 17 patients. These CBCT images were rigidly fused with planning CT images and the contours from the planning CT were transferred to CBCTs. Because of limited extension in the superior-inferior dimension contours with partial volumes in CBCTs were discarded. The treatment isocenter was placed by applying the clinically recorded shiftsmore » to the volume isocenter of the CBCT. Dose was recalculated at the shifted isocenter using a homogeneous dose calculation algorithm. Dosimetrically relevant changes defined as greater than 5% deviation from the clinically accepted plans but with homogeneous dose calculation were evaluated for the high dose (HD), intermediate dose (ID), and low dose (LD) CTVs, spinal cord, larynx, oropharynx, parotids, and submandibular glands. Results: Among seventeen rejected CBCTS, HD-CTVs, ID-CTVs, and LD-CTVs were completely included in the CBCTs for 17, 1, and 15 patients, respectively. The prescription doses to the HD-CTV, ID-CTV, and LD-CTV were received by < 95% of the CTV volumes in 5/17, 1/1, and 5/15 patients respectively. For the spinal cord, the maximum doses (D0.03cc) were increased > 5% in 13 of 17 patients. For the oropharynx, larynx, parotid, and submandibular glands, the mean dose of these organs at risk was increased > 5% in 7/17, 8/12, 11/16 and 6/16 patients, respectively. Conclusion: Timely review daily CBCTs for head and neck patients under daily CBCT guidance is important, and uncorrected setup errors can translate to dosimetrically relevant dose increases in organsat- risk and dose decreases in the clinical target volumes.« less
Moschetti, Viktoria; Schlecker, Christina; Wind, Sven; Goetz, Sophia; Schmitt, Holger; Schultz, Armin; Liesenfeld, Karl-Heinz; Wunderlich, Glen; Desch, Michael
2018-05-30
Schizophrenia and Alzheimer's disease are characterised by abnormalities in glutamatergic pathways related to N-methyl-D-aspartate receptor hypofunction. Glycine is an N-methyl-D-aspartate receptor co-agonist; inhibition of glycine transporter 1 may improve N-methyl-D-aspartate receptor function. This phase I, randomised, two-part study evaluated the safety, tolerability and pharmacokinetic profile of BI 425809, a novel glycine transporter 1 inhibitor, in healthy male and female volunteers. Part 1 evaluated BI 425809 10, 25, 50 or 75 mg once daily or 75 mg twice daily in young subjects, and 25 mg or 50 mg once daily in elderly subjects. Each dose group comprised 12 subjects who received BI 425809 (n = 9) or placebo (n = 3) for 14 days (day 1: single dose; days 4-14: multiple dosing). Part 2 compared pharmacokinetic profiles in 12 subjects who received a single dose of BI 425809 25 mg in the morning and evening. Pharmacokinetic profiles were similarly shaped for all dose groups. Median time to maximum plasma concentration was 3.0-4.5 h with steady state being reached between days 6 and 10. Pharmacokinetic parameters demonstrated dose linearity at the predicted therapeutic exposure range of BI 425809 ≤ 25 mg once daily, but increased less than dose proportionally for ≥ 50 mg once daily. All reported adverse events were of mild-to-moderate intensity, 51/84 (61%; part 1) subjects had one or more treatment-related adverse event, no serious adverse events occurred and no dose dependency was observed. Pharmacokinetic properties support both morning and evening dosing. BI 425809 was generally well tolerated at all tested doses. CLINICALTRIALS. NCT02337283.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, J; Hu, W; Xing, Y
Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, positionmore » and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.« less
Sonuga-Barke, Edmund J S; Swanson, James M; Coghill, David; DeCory, Heleen H; Hatch, Simon J
2004-09-30
Methylphenidate (MPH) is commonly prescribed in the treatment of Attention-Deficit/Hyperactivity Disorder or ADHD. Concerta and Metadate CD are once-daily formulations of MPH using different delivery mechanisms resulting in different pharmacokinetic profiles. A recent study (COMACS) showed that for near-milligram (mg) equivalent daily doses, Metadate CD provides greater symptom control in the morning (1.5 through 4.5 hours post-dose), while Concerta provides greater control in the early evening (12 hours post-dose). Non-inferential comparison of effects for different dose levels of the two formulations suggested that equivalent levels of morning symptom control could be obtained with lower daily doses of Metadate CD than Concerta; the situation being reversed in the evening. The current paper presents a secondary analysis that provides a statistical test of these observations. The COMACS study was a multi-center, double-blind crossover study of Metadate CD, Concerta and placebo with each treatment administered for 1 week. Children were assigned on the basis of their pre-trial dosage to either high (Metadate CD 60 mg; Concerta 54 mg), medium (Metadate CD 40 mg; Concerta 36 mg) or low doses (Metadate CD 20 mg; Concerta 18 mg) of MPH, and attended a laboratory school on the 7th day for assessment at 7 sessions across the day. For the post-hoc comparisons across dose levels presented here, total SKAMP scores with the active treatments (adjusted for placebo response) were analyzed using an analysis of covariance, with a combined measure modeling placebo response across all time period as the covariate. Symptom control from 1.5 through 6.0 hours post-dose was as good with lower doses of Metadate CD (20 and 40 mg) as with higher doses of Concerta (36 and 54 mg, respectively). Lower daily doses of Concerta (18 and 36 mg) and higher doses of Metadate CD (40 and 60 mg, respectively) gave equivalent control at 7.5 and 12 hours with Metadate CD giving better control from1.5 through 6.0 hours post-dose. Different delivery profiles of Metadate CD and Concerta can be exploited to limit total daily exposure to MPH while at the same targeting a specific, especially clinically significant, period of the day. These results need to be confirmed in a study in which children are randomly allocated to different dose levels of the two formulations and plasma MPH concentrations are assessed simultaneously.
Liu, Dongzhou J; Collaku, Agron
2018-01-01
Twice-daily sustained-release (SR) paracetamol (acetaminophen) offers convenient administration to chronic users. This study investigated at steady state (during the last 24 hours of a 3-day dosing period) the pharmacokinetics, bioequivalence, and safety of twice-daily SR paracetamol compared with extended-release (ER) and immediate-release (IR) paracetamol. In this open-label, randomized, multidose, 3-way crossover study, 28 healthy subjects received paracetamol SR (2 × 1000 mg twice daily), ER (2 × 665 mg 3 times daily), and IR (2 × 500 mg 4 times daily). At steady state, twice-daily SR paracetamol was bioequivalent to ER and IR paracetamol. The 90% confidence intervals for the ratios of geometric means were within the acceptance interval for SR/ER paracetamol (AUC 0-t , 0.973-1.033; AUC 0-24 , 0.974-1.034; AUC 0-∞ , 0.948-1.011; C max , 1.082-1.212; C av , 1.011-1.106) and SR/IR paracetamol (AUC 0-t , 0.969-1.029; AUC 0-24 , 0.968-1.027; AUC 0-∞ , 0.963-1.026; C max , 0.902-1.010; C av , 1.004-1.098). Given twice daily, the SR formulation demonstrated SR properties as expected. Mean time at or above a 4 μg/mL plasma concentration of paracetamol from 2 daily doses of the SR formulation was significantly longer than that from 4 daily doses of IR paracetamol. SR formulation also had a greater T max , a longer half-life, and lower C min compared with ER and IR paracetamol. All formulations were well tolerated. © 2017, The American College of Clinical Pharmacology.
Niu, Peng-Peng; Guo, Zhen-Ni; Jin, Hang; Xing, Ying-Qi; Yang, Yi
2016-01-01
Objective To examine the comparative efficacy and safety of different antiplatelet regimens in patients with prior non-cardioembolic ischaemic stroke or transient ischaemic attack. Design Systematic review and network meta-analysis. Data sources As on 31 March 2015, all randomised controlled trials that investigated the effects of antiplatelet agents in the long-term (≥3 months) secondary prevention of non-cardioembolic transient ischaemic attack or ischaemic stroke were searched and identified. Outcome measures The primary outcome measure of efficacy was serious vascular events (non-fatal stroke, non-fatal myocardial infarction and vascular death). The outcome measure of safety was any bleeding. Results A total of 36 randomised controlled trials (82 144 patients) were included. Network meta-analysis showed that cilostazol was significantly more effective than clopidogrel (OR 0.77, 95% credible interval 0.60–0.98) and low-dose (75–162 mg daily) aspirin (0.69, 0.55–0.86) in the prevention of serious vascular events. Aspirin (50 mg daily) plus dipyridamole (400 mg daily) and clopidogrel reduced the risk of serious vascular events compared with low-dose aspirin; however, the difference was not statistically significant. Furthermore, low-dose aspirin was as effective as higher daily doses. Cilostazol was associated with a significantly lower bleeding risk than most of the other regimens. Moreover, aspirin plus clopidogrel was associated with significantly more haemorrhagic events than other regimens. Direct comparisons showed similar results as the network meta-analysis. Conclusions Cilostazol was significantly more effective than aspirin and clopidogrel alone in the long-term prevention of serious vascular events in patients with prior non-cardioembolic ischaemic stroke or transient ischaemic attack. Cilostazol was associated with a significantly lower bleeding risk than low-dose aspirin (75–162 mg daily) and aspirin (50 mg daily) plus dipyridamole (400 mg daily). Low-dose aspirin was as effective as higher daily doses. However, further large, randomised, controlled, head-to-head trials are needed, especially in non-Asian ethnic groups. PMID:26988347
Kibengo, Freddie M.; Ruzagira, Eugene; Katende, David; Bwanika, Agnes N.; Bahemuka, Ubaldo; Haberer, Jessica E.; Bangsberg, David R.; Barin, Burc; Rooney, James F.; Mark, David; Chetty, Paramesh; Fast, Patricia; Kamali, Anatoli; Priddy, Frances H.
2013-01-01
Background Efficacy of oral pre-exposure prophylaxis (PrEP) in prevention of HIV acquisition has been evaluated using a daily regimen. However, adherence to long term daily medication is rarely perfect. Intermittent regimen may be a feasible alternative. Preclinical studies have demonstrated effectiveness of intermittent PrEP in SHIV prevention among animals. However, little is known about intermittent PrEP regimens. Design Seventy two HIV-uninfected volunteers in HIV serodiscordant couple relationships in Uganda were randomly assigned to receive daily oral Tenofovir/Emtricitabine (TDF/FTC-Truvada) or placebo, or intermittent (Monday, Friday and within 2 hours after sex, not to exceed one dose per day) oral TDF/FTC or placebo in a 2:1:2:1 ratio. Volunteers and study staff were blinded to drug assignment, but not to regimen assignment. Methods Volunteers were followed for 4 months after randomization, with monthly clinical and laboratory safety assessments and comprehensive HIV risk reduction services. Adherence was monitored using medication event monitoring system (MEMS) and self-report. Sexual activity data were collected via daily short text message (SMS) and self-report. HIV-specific immune responses were assessed by IFN-γ ELISPOT. Results Both daily and intermittent oral TDF/FTC regimens were well tolerated. Median MEMS adherence rates were 98% (IQR: 93-100) for daily PrEP regimen, 91% (IQR: 73-97) for fixed intermittent dosing and 45% (IQR: 20-63) for post-coital dosing. SMS response rate was 74%, but increased to 80% after excluding server outages; results may have been affected by the novelty of this measure. The majority of volunteers expressed willingness with no particular preference for either regimen. Conclusions Both daily and intermittent oral PrEP dosing regimens were safe. Adherence was high for daily and fixed intermittent dosing; post-coital dosing was associated with poor adherence. Fixed intermittent PrEP regimens may be feasible especially if a minimum effective drug concentration correlating with HIV prevention can be achieved with this dosing. Registration Clinicaltrials.gov number NCT00931346 PMID:24086333
MISR Level 2 TOA/Cloud Classifier parameters (MIL2TCCL_V2)
NASA Technical Reports Server (NTRS)
Diner, David J. (Principal Investigator)
The TOA/Cloud Classifiers contain the Angular Signature Cloud Mask (ASCM), a scene classifier calculated using support vector machine technology (SVM) both of which are on a 1.1 km grid, and cloud fractions at 17.6 km resolution that are available in different height bins (low, middle, high) and are also calculated on an angle-by-angle basis. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=17.6 km; Longitude_Resolution=17.6 km; Horizontal_Resolution_Range=10 km - < 50 km or approximately .09 degree - < .5 degree; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly, Daily - < Weekly].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chi, Y; Li, Y; Tian, Z
2015-06-15
Purpose: Pencil-beam or superposition-convolution type dose calculation algorithms are routinely used in inverse plan optimization for intensity modulated radiation therapy (IMRT). However, due to their limited accuracy in some challenging cases, e.g. lung, the resulting dose may lose its optimality after being recomputed using an accurate algorithm, e.g. Monte Carlo (MC). It is the objective of this study to evaluate the feasibility and advantages of a new method to include MC in the treatment planning process. Methods: We developed a scheme to iteratively perform MC-based beamlet dose calculations and plan optimization. In the MC stage, a GPU-based dose engine wasmore » used and the particle number sampled from a beamlet was proportional to its optimized fluence from the previous step. We tested this scheme in four lung cancer IMRT cases. For each case, the original plan dose, plan dose re-computed by MC, and dose optimized by our scheme were obtained. Clinically relevant dosimetric quantities in these three plans were compared. Results: Although the original plan achieved a satisfactory PDV dose coverage, after re-computing doses using MC method, it was found that the PTV D95% were reduced by 4.60%–6.67%. After re-optimizing these cases with our scheme, the PTV coverage was improved to the same level as in the original plan, while the critical OAR coverages were maintained to clinically acceptable levels. Regarding the computation time, it took on average 144 sec per case using only one GPU card, including both MC-based beamlet dose calculation and treatment plan optimization. Conclusion: The achieved dosimetric gains and high computational efficiency indicate the feasibility and advantages of the proposed MC-based IMRT optimization method. Comprehensive validations in more patient cases are in progress.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prokic, Vesna, E-mail: vesna.prokic@uniklinik-freiburg.de; Wiedenmann, Nicole; Fels, Franziska
2013-01-01
Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individualmore » brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Y; Zhao, J; Wang, W
2016-06-15
Purpose: Various radiotherapy planning methods for locally recurrent nasopharynx carcinoma (R-NPC) have been proposed. The purpose of this study was to compare carbon and proton therapy for the treatment of R-NPC in terms of dose coverage for target volume and sparing for organs at risk (OARs). Methods: Six patients who were suffering from R-NPC and treated using carbon therapy were selected for this study. Treatment plans with a total dose of 57.5Gy (RBE) in 23 fractions were made using SIEMENS Syngo V11. An intensity-modulated radiotherapy optimization method was chosen for carbon plans (IMCT) while for proton plans both intensity-modulated radiotherapymore » (IMPT) and single beam optimization (proton-SBO) methods were chosen. Dose distributions, dose volume parameters, and selected dosimetric indices for target volumes and OARs were compared for all treatment plans. Results: All plans provided comparable PTV coverage. The volume covered by 95% of the prescribed dose was comparable for all three plans. The average values were 96.11%, 96.24% and 96.11% for IMCT, IMPT, and proton-SBO respectively. A significant reduction of the 80% and 50% dose volumes were observed for the IMCT plans compared to the IMPT and proton-SBO plans. Critical organs lateral to the target such as brain stem and spinal cord were better spared by IMPT than by proton-SBO, while IMCT spared those organs best. For organs in the beam path, such as parotid glands, the mean dose results were similar for all three plans. Conclusion: Carbon plans yielded better dose conformity than proton plans. They provided similar or better target coverage while significantly lowering the dose for normal tissues. Dose sparing for critical organs in IMPT plans was better than proton-SBO, however, IMPT is known to be more sensitive to range uncertainties. For proton plans it is essential to find a balance between the two optimization methods.« less
Declines in Outpatient Antimicrobial Use in Canada (1995–2010)
Finley, Rita; Glass-Kaastra, Shiona K.; Hutchinson, Jim; Patrick, David M.; Weiss, Karl; Conly, John
2013-01-01
Background With rising reports of antimicrobial resistance in outpatient communities, surveillance of antimicrobial use is imperative for supporting stewardship programs. The primary objective of this article is to assess the levels of antimicrobial use in Canada over time. Methods Canadian antimicrobial use data from 1995 to 2010 were acquired and assessed by four metrics: population-adjusted prescriptions, Defined Daily Doses, spending on antimicrobials (inflation-adjusted), and average Defined Daily Doses per prescription. Linear mixed models were built to assess significant differences among years and antimicrobial groups, and to account for repeated measurements over time. Measures were also compared to published reports from European countries. Results Temporal trends in antimicrobial use in Canada vary by metric and antimicrobial grouping. Overall reductions were seen for inflation-adjusted spending, population-adjusted prescription rates and Defined Daily Doses, and increases were observed for the average number of Defined Daily Doses per prescription. The population-adjusted prescription and Defined Daily Doses values for 2009 were comparable to those reported by many European countries, while the average Defined Daily Dose per prescription for Canada ranked high. A significant reduction in the use of broad spectrum penicillins occurred between 1995 and 2004, coupled with increases in macrolide and quinolone use, suggesting that replacement of antimicrobial drugs may occur as new products arrive on the market. Conclusions There have been modest decreases of antimicrobial use in Canada over the past 15 years. However, continued surveillance of antimicrobial use coupled with data detailing antimicrobial resistance within bacterial pathogens affecting human populations is critical for targeting interventions and maintaining the effectiveness of these products for future generations. PMID:24146863
Chi, Yihebali; Yang, Jianliang; Yang, Sheng; Sun, Yongkun; Jia, Bo; Shi, Yuankai
2015-06-01
To determine the maximum tolerated dose (MTD), dose-limiting toxicity (DLT) and efficacy of sorafenib in combination with FOLFOX4 (oxaliplatin/leucovorin (LV)/5-fluorouracil) as first-line treatment for advanced gastric cancer, we performed a phase I dose-finding study in nine evaluable patients with unresectable locally advanced or metastatic gastric cancer or gastroesophageal junction adenocarcinoma. According to modified Fibonacci method, the design of this study was to guide elevation of the sorafenib dosage to the next level (from 200 mg twice daily to 400 mg twice daily and then, if tolerated, 600 mg twice daily). If the patient achieved complete response (CR), partial response (PR) or stable disease (SD) after eight cycles of treatment, combination chemotherapy was scheduled to be discontinued and sorafenib monotherapy continued at the original dose until either disease progression or unacceptable toxicity. In sorafenib 200 mg twice daily group, DLT was observed in 1 of 6 patients, and in 400 mg twice daily group, it was observed in 2 of 3 patients. Seven of 9 (77.8%) evaluable patients achieved PR, with a median overall survival (OS) of 11.8 [95% confidence interval (CI): 8.9-14.7] months. Common adverse effects include hand-foot syndrome, leukopenia, neutropenia, anorexia, and nausea. Twice-daily dosing of sorafenib 200 mg in combination with FOLFOX4 was proven effective and safe for the treatment of advanced gastric cancer, and could be an appropriate dosage for subsequent phase II clinical studies.
Issa, Jean-Pierre J; Roboz, Gail; Rizzieri, David; Jabbour, Elias; Stock, Wendy; O'Connell, Casey; Yee, Karen; Tibes, Raoul; Griffiths, Elizabeth A; Walsh, Katherine; Daver, Naval; Chung, Woonbok; Naim, Sue; Taverna, Pietro; Oganesian, Aram; Hao, Yong; Lowder, James N; Azab, Mohammad; Kantarjian, Hagop
2015-09-01
Hypomethylating agents are used to treat cancers driven by aberrant DNA methylation, but their short half-life might limit their activity, particularly in patients with less proliferative diseases. Guadecitabine (SGI-110) is a novel hypomethylating dinucleotide of decitabine and deoxyguanosine resistant to degradation by cytidine deaminase. We aimed to assess the safety and clinical activity of subcutaneously given guadecitabine in patients with acute myeloid leukaemia or myelodysplastic syndrome. In this multicentre, open-label, phase 1 study, patients from nine North American medical centres with myelodysplastic syndrome or acute myeloid leukaemia that was refractory to or had relapsed after standard treatment were randomly assigned (1:1) to receive subcutaneous guadecitabine, either once-daily for 5 consecutive days (daily × 5), or once-weekly for 3 weeks, in a 28-day treatment cycle. Patients were stratified by disease. A 3 + 3 dose-escalation design was used in which we treated patients with guadecitabine doses of 3-125 mg/m(2) in separate dose-escalation cohorts. A twice-weekly treatment schedule was added to the study after a protocol amendment. The primary objective was to assess safety and tolerability of guadecitabine, determine the maximum tolerated and biologically effective dose, and identify the recommended phase 2 dose of guadecitabine. Safety analyses included all patients who received at least one dose of guadecitabine. Pharmacokinetic and pharmacodynamic analyses to determine the biologically effective dose included all patients for whom samples were available. This study is registered with ClinicalTrials.gov, number NCT01261312. Between Jan 4, 2011, and April 11, 2014, we enrolled and treated 93 patients: 35 patients with acute myeloid leukaemia and nine patients with myelodysplastic syndrome in the daily × 5 dose-escalation cohorts, 28 patients with acute myeloid leukaemia and six patients with myelodysplastic syndrome in the once-weekly dose-escalation cohorts, and 11 patients with acute myeloid leukaemia and four patients with myelodysplastic syndrome in the twice-weekly dose-escalation cohorts. The most common grade 3 or higher adverse events were febrile neutropenia (38 [41%] of 93 patients), pneumonia (27 [29%] of 93 patients), thrombocytopenia (23 [25%] of 93 patients), anaemia (23 [25%] of 93 patients), and sepsis (16 [17%] of 93 patients). The most common serious adverse events were febrile neutropenia (29 [31%] of 93 patients), pneumonia (26 [28%] of 93 patients), and sepsis (16 [17%] of 93 patients). Six of the 74 patients with acute myeloid leukaemia and six of the 19 patients with myelodysplastic syndrome had a clinical response to treatment. Two dose-limiting toxicities were noted in patients with myelodysplastic syndrome at 125 mg/m(2) daily × 5, thus the maximum tolerated dose in patients with myelodysplastic syndrome was 90 mg/m(2) daily × 5. The maximum tolerated dose was not reached in patients with acute myeloid leukaemia. Potent dose-related DNA demethylation occurred on the daily × 5 regimen, reaching a plateau at 60 mg/m(2) (designated as the biologically effective dose). Guadecitabine given subcutaneously at 60 mg/m(2) daily × 5 is well tolerated and is clinically and biologically active in patients with myelodysplastic syndrome and acute myeloid leukaemia. Guadecitabine 60 mg/m(2) daily × 5 is the recommended phase 2 dose, and these findings warrant further phase 2 studies. Astex Pharmaceuticals, Stand Up To Cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bejarano Buele, A; Parsai, E
Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boardsmore » and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Araujo, C; Bardock, A; Berkelaar, S
2015-06-15
Purpose: The target volume for angiosarcoma of the scalp encompasses the entire scalp. Full scalp radiotherapy (FSRT) requires careful design of required bolus, immobilization and marking of the field before the patient CT is acquired. A VMAT multi-arc technique was designed to deliver FSRT for a patient with angiosarcoma of the scalp to a dose of 6000cGy in 25 fractions. Methods: A custom bolus helmet was fabricated from a 0.5 cm thick sheet of aquaplast material, which was molded to the patient’s head. With the bolus helmet in place the patient was then positioned supine on a H&N immobilization board.more » A custom vaclock bag positioned on a standard headrest and a thermoplastic mask were used to immobilize the patient. Additional bolus to cover the remaining treatment area was attached to the mask. We acquired two CT scans of the patient’s head, one in treatment position and an additional scan without the immobilization mask with wires marking the treatment area that the oncologist had delineated on the patient’s skin. The second scan was registered to the first and used to define the treatment CTV. A four-arc VMAT treatment planned using Varian-Eclipse was optimized to cover the skin with a PTV margin while sparing the brain and limiting the dose to the optic apparatus and lacrimal glands. Daily treatment setup was verified using anterior and lateral kV on-board-imaging. To verify the treated dose, TLDs were positioned on the patient’s scalp during one fraction. Results: With full dose coverage to the PTV, the mean dose to the brain was less than 24 Gy. The dose measured by the TLDs (mean difference 1%, standard deviation 4%)showed excellent agreement with the treatment planning calculation. Conclusion: FSRT delivered with a bolus helmet and a VMAT multi-arc technique can be accurately delivered with high dose uniformity and conformality.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurosawa, T; Moriya, S; Sato, M
2015-06-15
Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additionalmore » constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.« less
Niedzielski, J; Bluett, J; Williamson, R; Liao, Z; Gomez, D; Court, L
2012-06-01
To analyze the clinical impact of esophageal sparing on treatment plans for patients with grade 3 esophagitis. The treatment plans of 8 patients (project total: 20 patients) who were treated with IMRT and exhibited stage 3 esophagitis were re-planned to give a simulated clinical plan with dose distribution that mirrored our current clinical practice (74Gy to the target, and 5mm margins), and a plan that emphasized esophageal sparing. Doses to the esophagus, heart, cord, lung and PTV were compared. Comparing the esophageal sparing plan to the simulated clinical plan, the mean reduction in esophageal volume receiving 50, 55, 60, 65, and 70Gy were 2.0, 3.2, 5.0, 7.2, and 10.9 cm 3 , respectively. The mean reduction in the continuous length of esophagus receiving 50, 55, 60, 65, and 70Gy were 12, 24, 38, 40, and 47mm, respectively. The associated reduction in dose to 90% and 95% of the PTV was 2.2 and 3.8Gy, respectively. Of the 8 patients examined, 2 showed a significant decrease in PTV coverage (4.6Gy, 12.3Gy for 90% of PTV), 4 showed decreases under 1.1Gy, but 2 showed an increase of 1.4Gy and 0.5Gy for 90% PTV. Cord dose was maintained below 50Gy, and there was a slight increase in mean heart dose and mean lung dose of 2.4Gy, and 2.7Gy, respectively. Data will also be presented comparing these plans with the actual treated plans (for which the patients had grade 3 esophagitis) and plans that emphasize PTV coverage. Treatment planning to emphasize esophageal sparing can reduce the volume and continuous length of the esophagus which receives high doses. There is some associated modest reduction in PTV coverage. In summary, in many cases esophageal sparing can be accomplished for lung cancer cases while maintaining adequate PTV coverage, although there is variability between patients. © 2012 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, D; Sood, S; Badkul, R
2015-06-15
Purpose: To investigate the feasibility of using RapidArc (RA) treatment planning to reduce irradiation volume of normal lung and other organs at risk (OARs) in the treatment of inoperable non-small-cell lung cancer (NSCLC) patients. Methods: A retrospective treatment planning and delivery study was performed to compare target coverage and the volumes of the normal lung, spinal cord, heart and esophagus on 4D-CT scan above their dose tolerances delivered by RA vs. IMRT for ten inoperable NSCLC patients (Stage I-IIIB). RA plans consisted of either one-full or two-partial co-planar arcs used to treat 95% of the planning target volume (PTV) withmore » 6MV beam to a prescription of 66Gy in 33 fractions. IMRT plans were generated using 5–7 co-planar fields with 6MV beam. PTV coverage, dose-volume histograms, homogeneity/conformity indices (CI), total number of monitor units(MUs), beam-on time and delivery accuracy were compared between the two treatment plans. Results: Similar target coverage was obtained between the two techniques. RA (CI=1.02) provided more conformal plans without loss of homogeneity compared to IMRT plans (CI=1.12). Compared to IMRT, RA achieved a significant median dose reduction in V10 (3%), V20 (8%), and mean lung dose (3%) on average, respectively. On average, V5 was comparable between the two treatment plans. RA reduced mean esophagus (6%), mean heart (18%), and maximum spinal cord dose (7%), on average, respectively. Total number of MUs and beam-on time were each reduced almost by a factor of 2 when compared to IMRT-patient comfort, reduced intra-fraction-motion and leakage dose. The average IMRT and RA QA pass rate was about 98% for both types of plans for 3%/3mm criterion. Conclusion: Compared to IMRT plans, RA provided not only comparable target coverage, but also improved conformity, treatment time, and significant reduction in irradiation of OARs. This may potentially allow for target dose escalation without increase in normal tissue toxicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, R; Chisela, W
2015-06-15
Purpose: To investigate the use of EPID transit dosimetry for monitoring daily dose variations in radiation treatment delivery. Methods: A patient with head and neck cancer treated using nine field IMRT beams was used in this study. The prescription was 45 Gy in 25 fractions. A KV CBCT was acquired before each treatment on a Varian NTX linear accelerator. Integrated images using MV EPID were acquired for each treatment beam. Planning CT images, treatment plan, and daily integrated images were imported into a commercial QA software Dosimetry Check (v4r4 Math Resolutions, LLC, Columbia, MD) to calculate 3D dose of themore » day assuming 25 fractions treatment. Planning CT images were deformed and registered to each daily CBCT using Varian SmartAdapt (v11.MR2). ROIs were then propagated from planning CT to daily CBCT. The correlation between maximum, average dose of ROIs and ROI volume, center of mass shift, Dice Similarity Coefficient (DSC) were investigated. Results: Not all parameters investigated showed strong correlations. For PTV and CTV, the average dose has inverse correlation with their volume change (correlation coefficient −0.52, −0.50, respectively) and DSC (−0.59, −0.59, respectively). The average dose of right parotid has correlation with its volume change (0.56). The maximum dose of spinal cord has correlation with the center of mass superior-inferior shift (0.52) and inverse correlation with the center of mass anterior-posterior shift (−0.73). Conclusion: Transit dosimetry using EPID images collected during treatment delivery offers great potential to monitor daily dose variations due to patient anatomy change, motion, and setup errors in radiation treatment delivery. It can provide a patient-specific QA tool valuable for adaptive radiation therapy. Further work is needed to validate the technique.« less
Azathioprine-Induced Warfarin Resistance
Vazquez, Sara R; Rondina, Matthew T; Pendleton, Robert C
2011-01-01
OBJECTIVE To describe a case of azathioprine-induced warfarin resistance, present a literature review on warfarin–azathioprine interactions, and provide recommendations on appropriate management of this clinically significant interaction. CASE SUMMARY A 29-year-old female with Cogan’s syndrome experienced thrombosis of the left internal carotid artery. She was treated with an average weekly warfarin dose of 39 mg (5.5 mg daily) prior to beginning azathioprine therapy. Three weeks following initiation of azathioprine 150 mg daily, the international normalized ratio (INR) decreased from 1.9 (prior to the medication change) to 1.0 without any change in the warfarin dose or other relevant factors. Over several weeks, the patient’s warfarin dose was titrated up to 112 mg weekly (16 mg daily) to achieve an INR of 2.5 (a 188%, or 2.9-fold dose increase). Because of elevated liver enzyme levels, the azathioprine dosage was decreased to 100 mg daily. Within 2 weeks following that decrease, warfarin requirements decreased to 105 mg weekly (15 mg daily). DISCUSSION Azathioprine was the probable causative agent of warfarin resistance according to the Naranjo probability scale, and a possible causative agent according to the Drug Interaction Probability Scale. A literature search (PubMed, 1966–December 2007) revealed 8 case reports of this drug interaction and 2 cases involving a similar effect with 6-mercaptopurine, the active metabolite of azathioprine. The exact mechanism of the interaction remains unknown. Previously published case reports point to a rapid onset and offset of the warfarin–azathioprine interaction and a dose-dependent increase of at least 2.5-fold in warfarin dose requirement with the initiation of azathioprine 75–200 mg daily. CONCLUSIONS This case report and several others point toward azathioprine as a clinically significant inducer of warfarin resistance. Providers should anticipate the need for higher warfarin doses, warfarin dose adjustment, and close INR monitoring in patients receiving azathioprine or its active metabolite, 6-mercaptopurine. PMID:18505911
Barry, Aisling; Rock, Kathy; Sole, Claudio; Rahman, Mohammad; Pintilie, Melania; Lee, Grace; Fyles, Anthony; Koch, C Anne
The purpose of this study was to evaluate the impact of the active breathing control (ABC) technique on IMN coverage and organs at risk in patients planned for postmastectomy radiation therapy (PMRT), with the inclusion of the internal mammary lymph nodes (IMNs). The effect of body mass index (BMI) on recorded dosimetric parameters was examined in the same patient cohort. Fifty left-sided postmastectomy patients with breast cancer who underwent free-breathing (FB) and ABC-Elekta CT simulation scans were selected at random from an institutional breast cancer database between 2008 and 2014. The ABC plans were directly compared with FB plans from the same patient. The IMN planning target volume coverage met dosimetric criteria for coverage of receiving more than 90% of the prescribed dose (V90) >90%, although it decreased with ABC compared with FB (94.5% vs 98%, P < .001). Overall, ABC significantly reduced doses to all measured heart and left anterior descending coronary artery parameters, ipsilateral lung V20, and mean lung dose compared with FB (P < .001). There was no difference seen between the ABC and FB plans with respect to the dose to contralateral lung or contralateral breast. There was no correlation identified between BMI and any of the dosimetric parameters recorded from the ABC and FB plans. Our results suggest that ABC reduces IMN coverage in left-sided breast cancer patients planned for PMRT; however, dosimetric criteria for IMN coverage were still met, suggesting that this is not likely to be clinically significant. ABC led to significant sparing of organs at risk compared with FB conditions and was not affected by BMI. Collectively, the results support the use of ABC for breast cancer patients undergoing left-sided PMRT requiring regional nodal irradiation that includes the IMNs. Further prospective clinical studies are required to determine the impact of these results on late normal tissue effects. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Wilson, Rosamund J; Keith, Michael S; Preston, Peter; Copley, J Brian
2013-12-01
Sevelamer hydrochloride (SH) and lanthanum carbonate (LC) are calcium-free phosphate binders used for the management of hyperphosphatemia in patients with end-stage renal disease (ESRD). The objective of this analysis was to evaluate the real-world dose-relativity between SH and LC monotherapy in US patients with ESRD. This was a post hoc analysis of a 16-week, real-world study (Vemuri et al. in BMC Nephrol 12:49, 2011) of the efficacy of conversion to LC monotherapy from other phosphate binders. The SH:LC dose-relativity ratio, based on the mean daily dose, was calculated in the subset of patients from the Vemuri study who converted from SH to LC monotherapy and had available SH and LC dose data. A total of 950 patients converted from SH to LC monotherapy and had recorded dose data. The post hoc analysis population comprised 691 patients with available dose data for both SH at baseline and LC at week 16. The mean (SD) serum phosphate level at baseline was 5.91 (1.66) mg/dL. After conversion to LC monotherapy for 16 weeks, the mean (SD) serum phosphate level was 5.93 (1.85) mg/dL. The mean (SD) daily baseline SH dose was 7,703 (3,642) mg and the mean (SD) daily LC dose at week 16 was 2,800 (939) mg (9.6 versus 2.8 tablets, respectively; P < 0.0001), resulting in a SH:LC dose-relativity ratio of 2.8. The median individual patient SH:LC dose-relativity ratio was 2.6 (95% CI 2.6-2.8). Across baseline SH dose subgroups (2,400-4,800, >4,800-7,200, >7,200-9,600, and >9,600 mg/day), the mean daily SH dose was 4,051, 7,047, 9,253, and 13,150 mg, respectively. In comparison, the mean daily LC dose was 2,445-3,156 mg. Thus, patients requiring baseline SH doses >7,200 mg/day (41% of the analysis population) had higher SH:LC dose-relativity ratios of 3.1-4.2 (median individual patient ratios 3.1-4.0). In this post hoc analysis of real-world dose-relativity, the overall SH:LC dose-relativity ratio was 2.8 (median individual patient ratio 2.6 (95% CI 2.6-2.8). These findings are consistent with the World Health Organization-defined daily dose and previous studies of the relative phosphate binding capacity of the two drugs. Patients requiring SH doses >7,200 mg/day had higher SH:LC dose-relativities of 3.1-4.2 (median individual patient ratios 3.1-4.0). These findings have implications for the tablet burden and cost-effectiveness of SH and LC in the treatment of hyperphosphatemia.
Scheidel, Bernhard; Maritz, Martina A; Gschwind, Yves J; Steigerwald, Kerstin; Guth, Volker; Kovacs, Peter; Rey, Helene
2017-11-01
To evaluate and to compare the bioavailability, the influence of food intake on the bioavailability, and the safety and tolerability of a newly-developed oxycodone once-daily (OOD) prolonged-release tablet with an established oxycodone twice-daily (OTD) prolonged-release tablet after single-dose administration under fasting or fed conditions as well as after multiple-dose administration. Three single-center, open-label, randomized, balanced, two-treatment, two-period, two-sequence crossover studies were conducted. In each study, 36 healthy volunteers were randomized to receive 10 mg oxycodone daily as OOD (oxycodone HCL 10-mg PR tablets XL (Develco Pharma Schweiz AG, Pratteln, Switzerland); administration of 1 tablet in the morning) or as OTD (reference formulation: oxygesic 5-mg tablets (Mundipharma GmbH, Limburg an der Lahn, Germany); administration of 1 tablet in the morning and 1 tablet in the evening). Tablets were administered once daily or twice daily under fasting conditions (study 1) or under fed conditions (study 2) as well as after multiple-dose administration (study 3). A sufficient number of blood samples were taken for describing plasma profiles and for calculation of pharmacokinetic parameters. Plasma concentrations of oxycodone were determined by LC-MS/MS. Safety and tolerability were monitored and assessed in all three studies. Plasma profiles of OOD reveal sustained concentrations of oxycodone over the complete dosing interval of 24 hours. In comparison to the OTD reference formulation, the OOD test formulation showed a slightly slower increase of concentrations within the absorption phase and similar plasma concentrations at the maximum and at the end of the dosing interval (24 hours). Extent of bioavailability (AUC), maximum plasma concentrations (Cmax), and plasma concentrations at the end of the dosing interval (Cτ,ss,24h) of OOD could be classified as comparable to OTD considering 90% confidence intervals (CIs) and acceptance limits of 80.00 - 125.00%. Bioavailability of OOD was not influenced by concomitant food intake. OOD and OTD were generally well tolerated, a difference between the two products could not be observed. The new 10-mg OOD formulation provides sustained oxycodone plasma concentrations over the dosing interval of 24 hours and is suitable for once-daily administration. Bioavailability of OOD could be classified as comparable to the twice-daily administration of the OTD reference formulation. The new formulation widens and optimizes the range of strong opioid drug products in patient-centered therapy of chronic pain with simplified dosing and better compliance. .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sivakumar, R; Janardhan, N; Bhavani, P
Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 inmore » 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.« less
Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn
2015-11-01
Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less
Donepezil dosing strategies: pharmacokinetic considerations.
Gomolin, Irving H; Smith, Candace; Jeitner, Thomas M
2011-10-01
Donepezil (Aricept) is a cholinesterase inhibitor approved for the treatment of Alzheimer's disease. Immediate release formulations of 5- and 10-mg tablets were approved by the Food and Drug Administration in the United States in 1996. In July 2010, the Food and Drug Administration approved a 23-mg sustained release (SR) formulation. The SR formulation may provide additional benefit to patients receiving 10 mg daily but the incidence of adverse reactions is increased. We derived plasma concentration profiles for higher dose immediate-release formulations (15 mg once daily, 10 mg twice daily, and 20 mg once daily) and for the profile anticipated to result from the 23-mg SR formulation. Our model predicts similar steady-state concentration profiles for 10 mg twice daily, 20 mg once daily, and 23 mg SR once daily. This provides the theoretical basis for incremental immediate release dose escalation to minimize the emergence of adverse reactions and the potential to offer a cost-effective alternative to the SR formulation with currently approved generic immediate release formulations. Copyright © 2011 American Medical Directors Association. Published by Elsevier Inc. All rights reserved.
Palmsten, Kristin; Rolland, Matthieu; Hebert, Mary F; Clowse, Megan E B; Schatz, Michael; Xu, Ronghui; Chambers, Christina D
2018-04-01
To characterize prednisone use in pregnant women with rheumatoid arthritis using individual-level heat-maps and clustering individual trajectories of prednisone dose, and to evaluate the association between prednisone dose trajectory groups and gestational length. This study included pregnant women with rheumatoid arthritis who enrolled in the MotherToBaby Autoimmune Diseases in Pregnancy Study (2003-2014) before gestational week 20 and reported prednisone use without another oral glucocorticoid during pregnancy (n = 254). Information on medication use and pregnancy outcomes was collected by telephone interview plus by medical record review. Prednisone daily dose and cumulative dose were plotted by gestational day using a heat map for each individual. K-means clustering was used to cluster individual trajectories of prednisone dose into groups. The associations between trajectory group and demographics, disease severity measured by the Health Assessment Questionnaire at enrollment, and gestational length were evaluated. Women used prednisone 3 to 292 days during pregnancy, with daily doses ranging from <1 to 60 mg. Total cumulative dose ranged from 8 to 6225 mg. Disease severity, non-biologic disease modifying anti-rheumatic drug use, and gestational length varied significantly by trajectory group. After adjusting for disease severity, non-biologic disease modifying anti-rheumatic drug use, and other covariates, the highest vs lowest daily dose trajectory group was associated with reduced gestational age at delivery (β: -2.3 weeks (95%: -3.4, -1.3)), as was the highest vs lowest cumulative dose trajectory group (β: -2.6 weeks (95%: -3.6, -1.5)). In pregnant women with rheumatoid arthritis, patterns of higher prednisone dose were associated with shorter gestational length compared with lower dose. Copyright © 2018 John Wiley & Sons, Ltd.
Franks, Julie; Hirsch-Moverman, Yael; Loquere, Avelino S; Amico, K Rivet; Grant, Robert M; Dye, Bonnie J; Rivera, Yan; Gamboa, Robert; Mannheimer, Sharon B
2018-04-01
The HPTN 067/Alternative Dosing to Augment Pre-Exposure Prophylaxis Pill Taking (ADAPT) study evaluated daily and non-daily dosing schedules for oral pre-exposure prophylaxis (PrEP) to prevent HIV. A qualitative sub-study including focus groups and in-depth interviews was conducted among men who have sex with men participating in New York City to understand their experience with PrEP and study dosing schedules. The 37 sub-study participants were 68% black, 11% white, and 8% Asian; 27% were of Hispanic/Latino ethnicity. Mean age was 34 years. Themes resulting from qualitative analysis include: PrEP is a significant advance for HIV prevention; non-daily dosing of PrEP is congruent with HIV risk; and pervasive stigma connected to HIV and risk behavior is a barrier to PrEP adherence, especially for non-daily dosing schedules. The findings underscore how PrEP intersects with other HIV prevention practices and highlight the need to understand and address multidimensional stigma related to PrEP use.
Development of a twice daily dosing regimen of amoxicillin/clavulanate.
Bax, Richard
2007-12-01
Amoxicillin/clavulanate was first launched as a three times daily dosage for the treatment of a range of community-acquired infections. A decade later, it became necessary to introduce a twice daily dosage for reasons of convenience, compliance and to remain competitive with other recently launched antibacterials. Twice daily formulations of amoxicillin/clavulanate were developed in which the amount of amoxicillin was increased relative to clavulanate to provide equivalent bacteriological and clinical efficacy with no change in the safety profile. Equivalence of the two dosing regimens was confirmed by randomised clinical trials in adults (in skin and soft tissue, urinary tract and lower respiratory tract infections, sinusitis and recurrent tonsillitis) and paediatrics (in lower respiratory tract infections, otitis media and recurrent tonsillitis). An improvement in the safety profile, specifically gastrointestinal effects, due to the reduced daily dose of clavulanate, was noted for all patients, but particularly in children.
Albertson, Justin P; Clegg, Whitney J; Reid, Heather D; Arbise, Benjamin S; Pryde, Julie; Vaid, Awais; Thompson-Brown, Rachella; Echols, Fredrick
2016-07-29
Mumps is an acute viral disease characterized by fever and swelling of the parotid or other salivary glands. On May 1, 2015, the Illinois Department of Public Health (IDPH) confirmed a mumps outbreak at the University of Illinois at Urbana-Champaign. IDPH and the Champaign-Urbana Public Health District (C-UPHD) conducted an investigation and identified 317 cases of mumps during April 2015-May 2016. Because of sustained transmission in a population with high 2-dose coverage with measles-mumps-rubella (MMR) vaccine, a third MMR dose was recommended by IDPH, C-UPHD, and the university's McKinley Health Center. No formal recommendation for or against the use of a third MMR dose has been issued by the Advisory Committee on Immunization Practices (ACIP) (1). However, CDC has provided guidelines for use of a third dose as a control measure during mumps outbreaks in settings in which persons are in close contact with one another, where transmission is sustained despite high 2-dose MMR coverage, and when traditional control measures fail to slow transmission (2).
Mwamba, Guillaume Ngoie; Yoloyolo, Norbert; Masembe, Yolande; Nsambu, Muriel Nzazi; Nzuzi, Cathy; Tshekoya, Patrice; Dah, Barthelemy; Kaya, Guylain
2017-01-01
Vaccination coverage of the first dose of diphtheria-tetanus-pertussis-hepatitis B- Haemophilus influenza type b (pentavalent) vaccine for the City-Province of Kinshasain the years 2012 - 2014 wasbelow the national objective of 92%, with coverage less than 80% reported in 12 of the 35 health zones (HZ). The purpose of this study was to discern potential contributing factors to low vaccination coverage in Kinshasa. We conducted a multi-stage cluster household study of children 6 - 11 months in households residing in their current neighborhood for at least 3 months in the 12 high risk HZ in Kinshasa. Additional information on vaccination status of the children was collected at the health facility. Of the 1,513 households with a child 6-11 months old, 81% were eligible and participated. Among the 1224 children surveyed, 96% had received the first dose of pentavalent vaccine; 84% had received the third dose; and 71% had received all recommended vaccines for their age. Longer travel time to get to health facility (p=0.04) and shorter length of residence in the neighborhood (p=0.04) showed significant differences in relation to incomplete vaccination. Forty percent of children received their most recent vaccination in a facility outside of their HZ of residence. This survey found vaccination coverage in 12 HZs in Kinshasa was higher than estimates derived from administrative reports. The large percentage of children vaccinated outside of their HZ of residence demonstrates the challenge to use of the Reaching Every District strategy in urban areas.
Corriero, Rosemary; Gay, Jennifer L; Robb, Sara Wagner; Stowe, Ellen W
2018-02-01
The purpose of the study was to compare human papillomavirus (HPV) vaccination rates before and after Affordable Care Act (ACA) implementation among women, and examine differences according to insurance status and other sociodemographic variables. This was a cross-sectional analysis of the National Health and Nutrition Examination Survey questionnaire data. Participants (n = 4599) were from a random sample of the United States population. HPV vaccination status and number of doses received according to age, income, education, race, and insurance coverage. Over time, the proportion of women reporting HPV vaccination increased from 16.4% to 27.6%, and reporting vaccination completion (3 doses) increased from 56.8% to 67.2%. After ACA implementation, respondents were 3.3 times more likely to be vaccinated compared with before ACA implementation (95% confidence interval [CI], 2.0-5.5) adjusting for age, race, and insurance coverage. Similarly, respondents were more likely to have received 2 (odds ratio, 2.8; 95% CI, 1.5-5.3) or 3 doses (odds ratio, 5.8; 95% CI, 2.5-13.6). Vaccination uptake increased in a comparison of waves of data from before and after ACA implementation. This increase in vaccination coverage could be related to the increased preventative service coverage, which includes vaccines, required by the ACA. Future studies might focus on the role insurance has on vaccination uptake, and meeting Healthy People 2020 objectives for vaccination coverage. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Radiation Dose Reduction by Indication-Directed Focused z-Direction Coverage for Neck CT.
Parikh, A K; Shah, C C
2016-06-01
The American College of Radiology-American Society of Neuroradiology-Society for Pediatric Radiology Practice Parameter for a neck CT suggests that coverage should be from the sella to the aortic arch. It also recommends using CT scans judiciously to achieve the clinical objective. Our purpose was to analyze the potential dose reduction by decreasing the scan length of a neck CT and to assess for any clinically relevant information that might be missed from this modified approach. This retrospective study included 126 children who underwent a neck CT between August 1, 2013, and September 30, 2014. Alteration of the scan length for the modified CT was suggested on the topographic image on the basis of the indication of the study, with the reader blinded to the images and the report. The CT dose index volume of the original scan was multiplied by the new scan length to calculate the dose-length product of the modified study. The effective dose was calculated for the original and modified studies by using age-based conversion factors from the American Association of Physicists in Medicine Report No. 96. Decreasing the scan length resulted in an average estimated dose reduction of 47%. The average reduction in scan length was 10.4 cm, decreasing the overall coverage by 48%. The change in scan length did not result in any missed findings that altered management. Of the 27 abscesses in this study, none extended to the mediastinum. All of the lesions in question were completely covered. Decreasing the scan length of a neck CT according to the indication provides a significant savings in radiation dose, while not altering diagnostic ability or management. © 2016 by American Journal of Neuroradiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Y; Chang, A; Liu, Y
Purpose: Electron beams are commonly used for boost radiation following whole breast irradiation (WBI) to improve the in-breast local control. Proton beams have a finite range and a sharper distal dose falloff compared to electron beams, thus potentially sparing more heart and lung in breast treatment. The purpose of the study is to compare protons with electrons for boost breast treatment in terms of target coverage and normal tissue sparing. Methods: Six breast cancer patients were included in this study. All women received WBI to 45–50 Gy, followed by a 10–16.2 Gy boost with standard fractionation. If proton beams weremore » used for the boost treatment, an electron plan was retrospectively generated for comparison using the same CT set and structures, and vice versa if electron beams were used for treatment. Proton plans were generated using the treatment planning system (TPS) with two to three uniform scanning proton beams. Electron plans were generated using the Pinnacle TPS with one single en face beam. Dose-volume histograms (DVH) were calculated and compared between proton and electron boost plans. Results: Proton plans show a similar boost target coverage, similar skin dose, and much better heart and lung sparing. For an example patient, V95% for PTV was 99.98% and skin (5 mm shell) received a max dose close to the prescription dose for both protons and electrons; however, V2 and V5 for the ipsilateral lung and heart were 37.5%, 17.9% and 19.9%, 4.9% respectively for electrons, but were essentially 0 for protons. Conclusions: This dosimetric comparison demonstrates that while both proton therapy and electron therapy provided similar coverage and skin dose, proton therapy could largely reduce the dose to lung and heart, thus leading to potential less side effects.« less
Vaccher, Stefanie J; Gianacas, Christopher; Templeton, David J; Poynten, Isobel M; Haire, Bridget G; Ooi, Catriona; Foster, Rosalind; McNulty, Anna; Grulich, Andrew E; Zablotska, Iryna B
2017-01-01
The effectiveness of daily pre-exposure prophylaxis (PrEP) is well established. However, there has been increasing interest in non-daily dosing schedules among gay and bisexual men (GBM). This paper explores preferences for PrEP dosing schedules among GBM at baseline in the PRELUDE demonstration project. Individuals at high-risk of HIV were enrolled in a free PrEP demonstration project in New South Wales, Australia, between November 2014 and April 2016. At baseline, they completed an online survey containing detailed behavioural, demographic, and attitudinal questions, including their ideal way to take PrEP: daily (one pill taken every day), event-driven (pills taken only around specific risk events), or periodic (daily dosing during periods of increased risk). Overall, 315 GBM (98% of study sample) provided a preferred PrEP dosing schedule at baseline. One-third of GBM expressed a preference for non-daily PrEP dosing: 20% for event-driven PrEP, and 14% for periodic PrEP. Individuals with a trade/vocational qualification were more likely to prefer periodic to daily PrEP [adjusted odds ratio (aOR) = 4.58, 95% confidence intervals (95% CI): (1.68, 12.49)], compared to individuals whose highest level of education was high school. Having an HIV-positive main regular partner was associated with strong preference for daily, compared to event-driven PrEP [aOR = 0.20, 95% CI: (0.04, 0.87)]. Participants who rated themselves better at taking medications were more likely to prefer daily over periodic PrEP [aOR = 0.39, 95% CI: (0.20, 0.76)]. Individuals' preferences for PrEP schedules are associated with demographic and behavioural factors that may impact on their ability to access health services and information about PrEP and patterns of HIV risk. At the time of data collection, there were limited data available about the efficacy of non-daily PrEP schedules, and clinicians only recommended daily PrEP to study participants. Further research investigating how behaviours and PrEP preferences change correspondingly over time is needed. ClinicalTrials.gov NCT02206555. Registered 28 July 2014.
Deming, Dustin A; Ninan, Jacob; Bailey, Howard H; Kolesar, Jill M; Eickhoff, Jens; Reid, Joel M; Ames, Matthew M; McGovern, Renee M; Alberti, Dona; Marnocha, Rebecca; Espinoza-Delgado, Igor; Wright, John; Wilding, George; Schelman, William R
2014-04-01
Accumulating evidence shows evidence of efficacy with the combination of vorinostat and bortezomib in solid tumors. We previously examined a once-daily continuous dosing schedule of vorinostat in combination with bortezomib which was well tolerated in cycles 1 and 2; however, there was concern regarding the tolerability through multiple cycles. This study was conducted to evaluate an intermittent dosing schedule of vorinostat with bortezomib. Vorinostat was initially administered orally twice daily on days 1-14 with bortezomib IV on days 1, 4, 8, and 11 of a 21 day cycle. Two DLTs (elevated ALT and fatigue) were observed at dose level 1, thus the protocol was amended to administer vorinostat intermittently twice daily on days 1-4 and 8-11. 29 patients were enrolled; 13 men and 16 women. Common cancer types included sarcoma, pancreatic, colorectal, GIST, and breast. The most common Grade 3-4 toxicities at any dose level included thrombocytopenia, fatigue, increased ALT, elevated INR, and diarrhea. DLTs in the intermittent dosing scheduled included thrombocytopenia and fatigue. The Cmax and AUC for the intermittent dosing regimen were similar to those observed in the daily dosing. In this heavily pretreated population, stable disease was observed in patients with sarcoma, colorectal adenocarcinoma and GIST. The MTD was established at vorinostat 300 mg BID on days 1-4 and 8-11 and bortezomib 1.3 mg/m(2) IV on days 1, 4, 8, and 11 of a 21 day cycle. Tolerability was not improved with the intermittent dosing schedule of vorinostat when compared to continuous dosing.
Bakris, George L; Pitt, Bertram; Weir, Matthew R; Freeman, Mason W; Mayo, Martha R; Garza, Dahlia; Stasiv, Yuri; Zawadzki, Rezi; Berman, Lance; Bushinsky, David A
2015-07-14
Hyperkalemia is a potentially life-threatening condition predominantly seen in patients treated with renin-angiotensin-aldosterone system (RAAS) inhibitors with stage 3 or greater chronic kidney disease (CKD) who may also have diabetes, heart failure, or both. To select starting doses for a phase 3 study and to evaluate the long-term safety and efficacy of a potassium-binding polymer, patiromer, in outpatients with hyperkalemia. Phase 2, multicenter, open-label, dose-ranging, randomized clinical trial (AMETHYST-DN), conducted at 48 sites in Europe from June 2011 to June 2013 evaluating patiromer in 306 outpatients with type 2 diabetes (estimated glomerular filtration rate, 15 to <60 mL/min/1.73 m2 and serum potassium level >5.0 mEq/L). All patients received RAAS inhibitors prior to and during study treatment. Patients were stratified by baseline serum potassium level into mild or moderate hyperkalemia groups and received 1 of 3 randomized starting doses of patiromer (4.2 g [n = 74], 8.4 g [n = 74], or 12.6 g [n = 74] twice daily [mild hyperkalemia] or 8.4 g [n = 26], 12.6 g [n = 28], or 16.8 g [n = 30] twice daily [moderate hyperkalemia]). Patiromer was titrated to achieve and maintain serum potassium level 5.0 mEq/L or lower. The primary efficacy end point was mean change in serum potassium level from baseline to week 4 or prior to initiation of dose titration. The primary safety end point was adverse events through 52 weeks. Secondary efficacy end points included mean change in serum potassium level through 52 weeks. A total of 306 patients were randomized. The least squares mean reduction from baseline in serum potassium level at week 4 or time of first dose titration in patients with mild hyperkalemia was 0.35 (95% CI, 0.22-0.48) mEq/L for the 4.2 g twice daily starting-dose group, 0.51 (95% CI, 0.38-0.64) mEq/L for the 8.4 g twice daily starting-dose group, and 0.55 (95% CI, 0.42-0.68) mEq/L for the 12.6 g twice daily starting-dose group. In those with moderate hyperkalemia, the reduction was 0.87 (95% CI, 0.60-1.14) mEq/L for the 8.4 g twice daily starting-dose group, 0.97 (95% CI, 0.70-1.23) mEq/L for the 12.6 g twice daily starting-dose group, and 0.92 (95% CI, 0.67-1.17) mEq/L for the 16.8 g twice daily starting-dose group (P < .001 for all changes vs baseline by hyperkalemia starting-dose groups within strata). From week 4 through week 52, statistically significant mean decreases in serum potassium levels were observed at each monthly point in patients with mild and moderate hyperkalemia. Over the 52 weeks, hypomagnesemia (7.2%) was the most common treatment-related adverse event, mild to moderate constipation (6.3%) was the most common gastrointestinal adverse event, and hypokalemia (<3.5 mEq/L) occurred in 5.6% of patients. Among patients with hyperkalemia and diabetic kidney disease, patiromer starting doses of 4.2 to 16.8 g twice daily resulted in statistically significant decreases in serum potassium level after 4 weeks of treatment, lasting through 52 weeks. clinicaltrials.gov Identifier:NCT01371747.
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, Y; Bues, M; Schild, S
Purpose: We propose to apply a robust optimization model based on fuzzy-logic constraints in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to ensure the plan robustness under uncertainty and obtain the best trade-off between tumor dose coverage and organ-at-risk(OAR) sparing. Methods: Two IMPT plans were generated for 3 head-and-neck cancer patients: one used the planning target volume(PTV) method; the other used the fuzzy robust optimization method. In the latter method, nine dose distributions were computed - the nominal one and one each for ±3mm setup uncertainties along three cardinal axes andmore » for ±3.5% range uncertainty. For tumors, these nine dose distributions were explicitly controlled by adding hard constraints with adjustable parameters. For OARs, fuzzy constraints that allow the dose to vary within a certain range were used so that the tumor dose distribution was guaranteed by minimum compromise of that of OARs. We rendered this model tractable by converting the fuzzy constraints to linear constraints. The plan quality was evaluated using dose-volume histogram(DVH) indices such as tumor dose coverage(D95%), homogeneity(D5%-D95%), plan robustness(DVH band at D95%), and OAR sparing like D1% of brain and D1% of brainstem. Results: Our model could yield clinically acceptable plans. The fuzzy-logic robust optimization method produced IMPT plans with comparable target dose coverage and homogeneity compared to the PTV method(unit: Gy[RBE]; average[min, max])(CTV D95%: 59 [52.7, 63.5] vs 53.5[46.4, 60.1], CTV D5% - D95%: 11.1[5.3, 18.6] vs 14.4[9.2, 21.5]). It also generated more robust plans(CTV DVH band at D95%: 3.8[1.2, 5.6] vs 11.5[6.2, 16.7]). The parameters of tumor constraints could be adjusted to control the tradeoff between tumor coverage and OAR sparing. Conclusion: The fuzzy-logic robust optimization generates superior IMPT with minimum compromise of OAR sparing. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation. eRA Person ID(s) for the Principal Investigator: 11017970 (Research Supported by National Institutes of Health)« less
Immunisation coverage annual report, 2011.
Hull, Brynley P; Dey, Aditi; Menzies, Rob I; Brotherton, Julia M; McIntyre, Peter B
2013-12-31
This, the 5th annual immunisation coverage report, documents trends during 2011 for a range of standard measures derived from Australian Childhood Immunisation Register data, and National Human Papillomavirus (HPV) Vaccination Program Register data. The proportion of children 'fully vaccinated' at 12, 24 and 60 months of age was 91.4%, 92.2% and 89.5% respectively. Although pneumococcal vaccine had similar coverage at 12 months to other vaccines, coverage was lower for rotavirus at 12 months (83.8%) and varicella at 24 months (83.9%). By late 2011, the percentage of children who received the 1st dose of DTPa vaccine dose at less than 8 weeks of age was greater than 50% in 3 jurisdictions, the Australian Capital Territory, Victoria, and Queensland and at 70% for New South Wales and Tasmania. Although coverage at 12 months of age was lower among Indigenous children than non-Indigenous children in all jurisdictions, the extent of the difference varied. Overall, coverage at 24 months of age exceeded that at 12 months of age nationally. At 60 months of age, there was dramatic variation between individual jurisdictions, ranging from coverage 8% lower in Indigenous children in South Australia to 6% higher in the Northern Territory. As previously documented, vaccines recommended for Indigenous children only (hepatitis A and pneumococcal polysaccharide vaccine) had suboptimal coverage at 60% and 68%, respectively. On-time receipt (before 49 months of age) of vaccines by Indigenous children at the 60-month milestone age improved between 2010 (18%) and 2011 (19%) but the disparity in on-time vaccination between Indigenous and non-Indigenous children increased at all 3 age milestones. The percentage of vaccine objectors in 2011 (1.7%) has increased from 2007 when it was 1.1%. Coverage data for the 3rd dose of HPV from the national HPV register in the school catch up program was 71% but was substantially lower for the catch-up program for women outside school (39%-67%), although this was an improvement from 2010. This work is copyright. Apart from any use as permitted under the Copyright Act 1968, no part may be reproduced by any process without prior written permission from the Commonwealth. Requests and inquiries concerning reproduction and rights should be addressed to the Commonwealth Copyright Administration, Attorney General's Department, Robert Garran Offices, National Circuit, Barton ACT 2600 or posted at http://www.ag.gov.au/cca.
Khan, Iqbal Ansary; Saha, Amit; Chowdhury, Fahima; Khan, Ashraful Islam; Uddin, Md Jasim; Begum, Yasmin A; Riaz, Baizid Khoorshid; Islam, Sanjida; Ali, Mohammad; Luby, Stephen P; Clemens, John D; Cravioto, Alejandro; Qadri, Firdausi
2013-12-09
A feasibility study of an oral cholera vaccine was carried out to test strategies to reach high-risk populations in urban Mirpur, Dhaka, Bangladesh. The study was cluster randomized, with three arms: vaccine, vaccine plus safe water and hand washing practice, and no intervention. High risk people of age one year and above (except pregnant woman) from the two intervention arms received two doses of the oral cholera vaccine, Shanchol™. Vaccination was conducted between 17th February and 16th April 2011, with a minimum interval of fourteen days between two doses. Interpersonal communication preceded vaccination to raise awareness amongst the target population. The number of vaccine doses used, the population vaccinated, left-out, drop out, vaccine wastage and resources required were documented. Fixed outreach site vaccination strategy was adopted as the mode of vaccine delivery. Additionally, mobile vaccination sites and mop-up activities were carried out to reach the target communities. Of the 172,754 target population, 141,839 (82%) and 123,666 (72%) received complete first and second doses of the vaccine, respectively. Dropout rate from the first to the second dose was 13%. Two complete doses were received by 123,661 participants. Vaccine coverage in children was 81%. Coverage was significantly higher in females than in males (77% vs. 66%, P<0.001). Vaccine wastage for delivering the complete doses was 1.2%. The government provided cold-chain related support at no cost to the project. Costs for two doses of vaccine per-person were US$3.93, of which US$1.63 was spent on delivery. Cost for delivering a single dose was US$0.76. We observed no serious adverse events. Mass vaccination with oral cholera vaccine is feasible for reaching high risk endemic population through the existing national immunization delivery system employed by the government. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Seasonal influenza vaccine dose distribution in 157 countries (2004-2011).
Palache, Abraham; Oriol-Mathieu, Valerie; Abelin, Atika; Music, Tamara
2014-11-12
Globally there are an estimated 3-5 million cases of severe influenza illness every year, resulting in 250,000-500,000 deaths. At the World Health Assembly in 2003, World Health Organization (WHO) resolved to increase influenza vaccine coverage rates (VCR) for high-risk groups, particularly focusing on at least 75% of the elderly by 2010. But systematic worldwide data have not been available to assist public health authorities to monitor vaccine uptake and review progress toward vaccination coverage targets. In 2008, the International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply task force (IFPMA IVS) developed a survey methodology to assess global influenza vaccine dose distribution. The current survey results represent 2011 data and demonstrate the evolution of the absolute number distributed between 2004 and 2011 inclusive, and the evolution in the per capita doses distributed in 2008-2011. Global distribution of IFPMA IVS member doses increased approximately 86.9% between 2004 and 2011, but only approximately 12.1% between 2008 and 2011. The WHO's regions in Eastern Mediterranean (EMRO), Southeast Asian (SEARO) and Africa (AFRO) together account for about 47% of the global population, but only 3.7% of all IFPMA IVS doses distributed. While distributed doses have globally increased, they have decreased in EURO and EMRO since 2009. Dose distribution can provide a reasonable proxy of vaccine utilization. Based on the dose distribution, we conclude that seasonal influenza VCR in many countries remains well below the WHA's VCR targets and below the recommendations of the Council of the European Union in EURO. Inter- and intra-regional disparities in dose distribution trends call into question the impact of current vaccine recommendations at achieving coverage targets. Additional policy measures, particularly those that influence patients adherence to vaccination programs, such as reimbursement, healthcare provider knowledge, attitudes, practices, and communications, are required for VCR targets to be met and benefit public health. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Takács, István; Tóth, Béla E; Szekeres, László; Szabó, Boglárka; Bakos, Bence; Lakatos, Péter
2017-01-01
The comparative efficacy and safety profiles of selected daily 1000 IU, weekly 7000 IU and monthly 30,000 IU vitamin D 3 -not previously investigated-will be evaluated. Here, a prospective, randomized clinical trial, comparing efficacy and safety of a daily single dose of 1000 IU (group A) to a once-weekly 7000 IU dose (group B), or monthly 30,000 IU dose (group C) of vitamin D 3 . The present study is a controlled, randomized, open-label, multicenter clinical trial, 3 months in duration. Sixty-four adult subjects with vitamin D deficiency (25OHD<20 ng/ml), were included according to the inclusion and exclusion criteria. Dose-responses for increases in serum vitamin 25OHD were statistically equivalent for each of the three groups: A, B and C. Outcomes were 13.0 ± 1.5; 12.6 ± 1.1 and 12.9 ± 0.9 ng/ml increases in serum 25OHD per 1000 IU, daily, weekly and monthly, respectively. The treatment of subjects with selected doses restored 25OHD values to levels above 20 ng/ml in all groups. Treatment with distinct administration frequency of vitamin D 3 did not exhibit any differences in safety parameters. The daily, weekly and monthly administrations of daily equivalent of 1000 IU of vitamin D 3 provide equal efficacy and safety profiles.
Horowitz, David P; Wang, Tony J C; Wuu, Cheng-Shie; Feng, Wenzheng; Drassinower, Daphnie; Lasala, Anita; Pieniazek, Radoslaw; Cheng, Simon; Connolly, Eileen P; Lassman, Andrew B
2014-11-01
We examined the fetal dose from irradiation of glioblastoma during pregnancy using intensity modulated radiation therapy (IMRT), and describe fetal dose minimization using mobile shielding devices. A case report is described of a pregnant woman with glioblastoma who was treated during the third trimester of gestation with 60 Gy of radiation delivered via a 6 MV photon IMRT plan. Fetal dose without shielding was estimated using an anthropomorphic phantom with ion chamber and diode measurements. Clinical fetal dose with shielding was determined with optically stimulated luminescent dosimeters and ion chamber. Clinical target volume (CTV) and planning target volume (PTV) coverage was 100 and 98 % receiving 95 % of the prescription dose, respectively. Normal tissue tolerances were kept below quantitative analysis of normal tissue effects in the clinic (QUANTEC) recommendations. Without shielding, anthropomorphic phantom measurements showed a cumulative fetal dose of 0.024 Gy. In vivo measurements with shielding in place demonstrated a cumulative fetal dose of 0.016 Gy. The fetal dose estimated without shielding was 0.04 % and with shielding was 0.026 % of the target dose. In vivo estimation of dose equivalent received by the fetus was 24.21 mSv. Using modern techniques, brain irradiation can be delivered to pregnant patients in the third trimester with very low measured doses to the fetus, without compromising target coverage or normal tissue dose constraints. Fetal dose can further be reduced with the use of shielding devices, in keeping with the principle of as low as reasonably achievable.
2000-05-08
The frequent coverage provided by NASA SeaWinds instrument on the QuikScat satellite in 1999 provided unprecedented capability to monitor daily and seasonal changes in the key melt zones of Greenland.
Bendell, Johanna C; Javle, Milind; Bekaii-Saab, Tanios S; Finn, Richard S; Wainberg, Zev A; Laheru, Daniel A; Weekes, Colin D; Tan, Benjamin R; Khan, Gazala N; Zalupski, Mark M; Infante, Jeffrey R; Jones, Suzanne; Papadopoulos, Kyriakos P; Tolcher, Anthony W; Chavira, Renae E; Christy-Bittel, Janna L; Barrett, Emma; Patnaik, Amita
2017-01-01
Background: Binimetinib (MEK162; ARRY-438162) is a potent and selective oral MEK 1/2 inhibitor. This phase 1 study determined the maximum tolerated dose (MTD), safety, pharmacokinetic and pharmacodynamic profiles, and preliminary anti-tumour activity of binimetinib in patients with advanced solid tumours, with expansion cohorts of patients with biliary cancer or KRAS- or BRAF-mutant colorectal cancer. Methods: Binimetinib was administered twice daily. Expansion cohorts were enroled after MTD determination following a 3+3 dose-escalation design. Pharmacokinetic properties were determined from plasma samples. Tumour samples were assessed for mutations in RAS, RAF, and other relevant genes. Pharmacodynamic properties were evaluated in serum and skin punch biopsy samples. Results: Ninety-three patients received binimetinib (dose-escalation phase, 19; expansion, 74). The MTD was 60 mg twice daily, with dose-limiting adverse events (AEs) of dermatitis acneiform and chorioretinopathy. The dose for expansion patients was subsequently decreased to 45 mg twice daily because of the frequency of treatment-related ocular toxicity at the MTD. Common AEs across all dose levels included rash (81%), nausea (56%), vomiting (52%), diarrhoea (51%), peripheral oedema (46%), and fatigue (43%); most were grade 1/2. Dose-proportional increases in binimetinib exposure were observed and target inhibition was demonstrated in serum and skin punch biopsy samples. Three patients with biliary cancer had objective responses (one complete and two partial). Conclusions: Binimetinib demonstrated a manageable safety profile, target inhibition, and dose-proportional exposure. The 45 mg twice daily dose was identified as the recommended phase 2 dose. The three objective responses in biliary cancer patients are encouraging and support further evaluation in this population. PMID:28152546
Madu, C N; Quint, D J; Normolle, D P; Marsh, R B; Wang, E Y; Pierce, L J
2001-11-01
To delineate with computed tomography (CT) the anatomic regions containing the supraclavicular (SCV) and infraclavicular (IFV) nodal groups, to define the course of the brachial plexus, to estimate the actual radiation dose received by these regions in a series of patients treated in the traditional manner, and to compare these doses to those received with an optimized dosimetric technique. Twenty patients underwent contrast material-enhanced CT for the purpose of radiation therapy planning. CT scans were used to study the location of the SCV and IFV nodal regions by using outlining of readily identifiable anatomic structures that define the nodal groups. The brachial plexus was also outlined by using similar methods. Radiation therapy doses to the SCV and IFV were then estimated by using traditional dose calculations and optimized planning. A repeated measures analysis of covariance was used to compare the SCV and IFV depths and to compare the doses achieved with the traditional and optimized methods. Coverage by the 90% isodose surface was significantly decreased with traditional planning versus conformal planning as the depth to the SCV nodes increased (P < .001). Significantly decreased coverage by using the 90% isodose surface was demonstrated for traditional planning versus conformal planning with increasing IFV depth (P = .015). A linear correlation was found between brachial plexus depth and SCV depth up to 7 cm. Conformal optimized planning provided improved dosimetric coverage compared with standard techniques.
Short-term digestive tolerance of different doses of NUTRIOSE FB, a food dextrin, in adult men.
van den Heuvel, E G H M; Wils, D; Pasman, W J; Bakker, M; Saniez, M-H; Kardinaal, A F M
2004-07-01
To determine the tolerance of increasing dosages of an incompletely hydrolysed and/or incompletely absorbed food dextrin coming from wheat starch, NUTRIOSE FB, at daily levels of 10 and 15 g up to 60 and 80 g, respectively. A randomized, double-blind, multiple dose, placebo-controlled, combined crossover and parallel trial. The metabolic ward of TNO Nutrition and Food Research. A total of 20 healthy men (age 31.7 +/- 9.1 y; BMI 24.5 +/- 2.9 kg/m2). One group of 10 subjects consumed on top of their diet 10, 30 and 60 g of NUTRIOSE FB or maltodextrin (placebo) daily. The other group of 10 subjects consumed 15, 45 and 80 g daily. Each dose was consumed for 7 days. Compared with placebo, flatulence occurred more frequently over the last 6 days on 30, 60 or 80 g/day of NUTRIOSE FB (P < 0.05). During the last 24 h, that is, days 6-7, of 60 and 80 g/day of NUTRIOSE FB, the frequency of flatulence was even higher (P < 0.05). During the last 24 h on a daily dose of 60 g NUTRIOSE FB, the frequency of defecation decreased (P < 0.05). Bloating occurred more often during the last 24 h on 80 g/day of NUTRIOSE FB (P < 0.05). None of the doses of NUTRIOSE FB resulted in diarrhoea. Compared to baseline levels, breath H2 excretion, which was only measured after a week with 10 and 15 g of NUTRIOSE FB daily, increased (P < 0.05). However, no difference in area under the curve was found. NUTRIOSE FB is a fermentable carbohydrate and is well tolerated up to a dose of 45 g daily. Higher daily dosages (60 and 80 g) may result in flatulence, but does not result in diarrhoea. TNO Nutrition and Food Research was assigned by Roquette Frères to perform the study.
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.
The expanding role of fluoroquinolones.
Schaeffer, Anthony J
2003-02-01
There has been a growing rate of resistance among common urinary tract pathogens, such as Escherichia coli, to traditional antimicrobial therapies including the "gold standard" trimethoprim-sulfamethoxazole (TMP-SMX). Consequently, fluoroquinolone antimicrobial agents have taken on an expanding management role for UTIs. In fact, the recent Infectious Diseases Society of America clinical management guidelines for UTI recommend fluoroquinolones as first-line therapy for uncomplicated UTI in areas where resistance is likely to be of concern. Fluoroquinolones have demonstrated high bacteriologic and clinical cure rates, as well as low rates of resistance, among most common uropathogens. There are currently 7 fluoroquinolones with indications for UTI in the United States. However, only 3 are commonly used: levofloxacin, ciprofloxacin, and, to a lesser extent, gatifloxacin. Many of the fluoroquinolone agents have once-daily dosing regimens, enhancing patient adherence. In addition, levofloxacin and gatifloxacin have same-dose bioequivalency between their intravenous and oral formulations, allowing for "switch" or step-down therapy from parenteral to oral formulations of the same agent at the same dose. Fluoroquinolones are indicated for the management of acute uncomplicated UTIs, as well as complicated and severe UTI and pyelonephritis, in adults. They are the first-line treatment of acute uncomplicated cystitis in patients who cannot tolerate sulfonamides or TMP, who live in geographic areas with known resistance >10% to 20% to TMP-SMX, or who have risk factors for such resistance. Fluoroquinolone properties include a broad spectrum of coverage, low rates of resistance, and good safety profiles.
Inaba, Naoko; Sato, Toshiro; Yamashita, Takatoshi
2015-01-01
Vitamin K is essential for bone health, but the effects of low-dose vitamin K intake in Japanese subjects remain unclear. We investigated the effective minimum daily menaquinone-7 dose for improving osteocalcin γ-carboxylation. Study 1 was a double-blind, randomized controlled dose-finding trial; 60 postmenopausal women aged 50-69 y were allocated to one of four dosage group and consumed 0, 50, 100, or 200 μg menaquinone-7 daily for 4 wk, respectively, with a controlled diet in accordance with recommended daily intakes for 2010 in Japan. Study 2 was a double-blind, randomized placebo-controlled trial based on the results of Study 1; 120 subjects aged 20-69 y were allocated to the placebo or MK-7 group and consumed 0 or 100 μg menaquinone-7 daily for 12 wk, respectively. In both studies, circulating carboxylated osteocalcin and undercarboxylated osteocalcin were measured. The carboxylated osteocalcin/undercarboxylated osteocalcin ratio decreased significantly from baseline in the 0 μg menaquinone-7 group, in which subjects consumed the recommended daily intake of vitamin K with vitamin K1 and menaquinone-4 (Study 1). Menaquinone-7 increased the carboxylated osteocalcin/undercarboxylated osteocalcin ratio dose dependently, and significant effects were observed in both the 100 and 200 μg groups compared with the 0 μg group. Undercarboxylated osteocalcin concentrations decreased significantly, and the carboxylated osteocalcin/undercarboxylated osteocalcin ratio increased significantly in the 100 μg menaquinone-7 group compared with the placebo group (Study 2). Daily menaquinone-7 intake ≥100 μg was suggested to improve osteocalcin γ-carboxylation.
A way to improve dose rate laser simulation adequacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skorobogatov, P.K.; Nikiforov, A.Y.; Demidov, A.A.
1998-12-01
A method for improving laser simulation of dose rate radiation in silicon IC`s (Integrated Circuit) is analyzed based on the application of noncoherent laser radiation. Experimental validation was performed using test structures with up to 90% surface metallization coverage.
Proxy-based reconstruction of erythemal UV doses over Estonia for 1955 2004
NASA Astrophysics Data System (ADS)
Eerme, K.; Veismann, U.; Lätt, S.
2006-08-01
A proxy-based reconstruction of the erythemally-weighted UV doses for 1955-2004 has been performed for the Tartu-Tõravere Meteorological Station (58°16' N, 26°28' E, 70 m a.s.l.) site. The pyrheliometer-measured daily sum of direct irradiance on partly cloudy and clear days, and the pyranometer-measured daily sum of global irradiance on overcast days were used as the cloudiness influence related proxies. The TOMS ozone data have been used for detecting the daily deviations from the climatic value (averaged annual cycle). In 1998-2004, the biases between the measured and reconstructed daily doses in 55.5% of the cases were within ±10% and in 83.5% of the cases within ±20%, on average. In the summer half-year these amounts were 62% and 88%, respectively. In most years the results for longer intervals did not differ significantly, if no correction was made for the daily deviations of total ozone from its climatic value. The annual and summer half-yearly erythemal doses (contributing, on average, 89% of the annual value) agreed within ±2%, except for the years after major volcanic eruptions and one extremely fine weather year (2002). Using the daily relative sunshine duration as a proxy without detailed correction for atmospheric turbidity results in biases of 2-4% in the summer half-yearly dose in the years after major volcanic eruptions and a few other years of high atmospheric turbidity. The year-to-year variations of the summer half-yearly erythemal dose in 1955-2004 were found to be within 92-111% relative to their average value. Exclusion of eight extreme years reduces this range for the remaining to 95-105.5%. Due to the quasi-periodic alternation of wet and dry periods, the interval of cloudy summers 1976-1993 regularly manifests summer half-yearly erythemal dose values lower than the 1955-2004 average. Since 1996/1997 midwinters have been darker than on average.
Huynh, Julie; Lu, Thao; Liew, Danny; Doery, James Cg; Tudball, Ronald; Jona, Madeleine; Bhamjee, Roisin; Rodda, Christine P
2017-02-01
There are no published data to demonstrate the efficacy of bolus dose vitamin D in newborn infants. The study sought to evaluate this alternative approach of supplementation. This single centre, open randomised controlled trial was conducted from August 2013 to May 2014. It compared the efficacy and safety of daily (400 IU) versus a bolus dose (50 000 IU) of cholecalciferol in newborn infants of vitamin D deficient mothers. The primary outcome measure was the rate of 25 hydroxyvitamin D (25OHD) repletion-defined as 25OHD greater than 50 nmol/L. The secondary objective was determining safety using adjusted total serum calcium. Of 70 eligible infants, 36 received a daily dose and 34 received a single high-dose cholecalciferol. Mean 25OHD in the bolus group (154 nmol/L, 95% confidence interval (CI) 131-177) was higher than the daily group (48 nmol/L, 95% CI 42-54) at 1-2 weeks of age. This was reversed at 3-4 months, (65 nmol/L, 95% CI 59-71) compared with the daily group (81 nmol/L, 95% CI 77-85). More infants in the single bolus group achieved vitamin D repletion (100 vs. 31%) at 1-2 weeks. By 3-4 months, both groups achieved similar vitamin D repletion rates (91 vs. 89%). Mean adjusted total serum calcium in the bolus group were normal at 1-2 weeks (2.73 mmol/L) and 3-4 months (2.55 mmol/L). Single bolus dosing of 50 000 IU cholecalciferol achieves higher 25OHD repletion rates at 1-2 weeks of age compared with daily dosing, but repletion rates were similar by 3-4 months. There was no hypercalcaemia documented with single bolus dosing in this study. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
Lewin, Jeremy; Soria, Jean-Charles; Stathis, Anastasios; Delord, Jean-Pierre; Peters, Solange; Awada, Ahmad; Aftimos, Philippe G; Bekradda, Mohamed; Rezai, Keyvan; Zeng, Zhen; Hussain, Azher; Perez, Susan; Siu, Lillian L; Massard, Christophe
2018-05-07
Purpose Birabresib (MK-8628/OTX015) is a first-in-class bromodomain inhibitor with activity in select hematologic tumors. Safety, efficacy, and pharmacokinetics of birabresib were evaluated in patients with castrate-resistant prostate cancer, nuclear protein in testis midline carcinoma (NMC), and non-small-cell lung cancer in this phase Ib study. Patients and Methods Forty-seven patients were enrolled to receive birabresib once daily at starting doses of 80 mg continuously (cohort A) or 100 mg for 7 consecutive days (cohort B) in 21-day cycles using a parallel dose escalation 3 + 3 design. The primary objective was occurrence of dose-limiting toxicities (DLTs) and determination of the recommended phase II dose. Results Of 46 treated patients, 26 had castrate-resistant prostate cancer, 10 NMC, and 10 non-small-cell lung cancer. For cohort A, four of 19 (21%) evaluable patients had DLTs at 80 mg once daily (grade 3 thrombocytopenia [n = 3], ALT/hyperbilirubinemia [n = 1]) and two of three had DLTs at 100 mg once daily (grade 2 anorexia and nausea with treatment delay > 7 days [n = 1], grade 4 thrombocytopenia [n = 1]). No DLTs occurred in cohort B. Of 46 patients, 38 (83%) had treatment-related adverse events (diarrhea, 17 [37%]; nausea, 17 [37%]; anorexia, 14 [30%]; vomiting, 12 [26%]; thrombocytopenia 10 [22%]). Three patients with NMC (80 mg once daily) had a partial response (Response Evaluation Criteria in Solid Tumors [RECIST] version 1.1) with duration of 1.4 to 8.4 months. Pharmacokinetic analysis indicated a dose-proportional increase in birabresib exposure and rapid absorption. Conclusion The recommended phase II dose of birabresib in patients with select solid tumors is 80 mg once daily with continuous dosing. Birabresib has dose-proportional exposure and a favorable safety profile, with clinical activity observed in NMC. Future studies of birabresib must consider intermittent scheduling to possibly mitigate the toxicities of chronic dosing.
Kardar, Laleh; Li, Yupeng; Li, Xiaoqiang; Li, Heng; Cao, Wenhua; Chang, Joe Y.; Liao, Li; Zhu, Ronald X.; Sahoo, Narayan; Gillin, Michael; Liao, Zhongxing; Komaki, Ritsuko; Cox, James D.; Lim, Gino; Zhang, Xiaodong
2015-01-01
Purpose The primary aim of this study was to evaluate the impact of interplay effects for intensity-modulated proton therapy (IMPT) plans for lung cancer in the clinical setting. The secondary aim was to explore the technique of iso-layered re-scanning for mitigating these interplay effects. Methods and Materials Single-fraction 4D dynamic dose without considering re-scanning (1FX dynamic dose) was used as a metric to determine the magnitude of dosimetric degradation caused by 4D interplay effects. The 1FX dynamic dose was calculated by simulating the machine delivery processes of proton spot scanning on moving patient described by 4D computed tomography (4DCT) during the IMPT delivery. The dose contributed from an individual spot was fully calculated on the respiratory phase corresponding to the life span of that spot, and the final dose was accumulated to a reference CT phase by using deformable image registration. The 1FX dynamic dose was compared with the 4D composite dose. Seven patients with various tumor volumes and motions were selected. Results The CTV prescription coverage for the 7 patients were 95.04%, 95.38%, 95.39%, 95.24%, 95.65%, 95.90%, and 95.53%, calculated with use of the 4D composite dose, and were 89.30%, 94.70%, 85.47%, 94.09%, 79.69%, 91.20%, and 94.19% with use of the 1FX dynamic dose. For the 7 patients, the CTV coverage, calculated by using single-fraction dynamic dose, were 95.52%, 95.32%, 96.36%, 95.28%, 94.32%, 95.53%, and 95.78%, using maximum MU limit value of 0.005. In other words, by increasing the number of delivered spots in each fraction, the degradation of CTV coverage improved up to 14.6%. Conclusions Single-fraction 4D dynamic dose without re-scanning was validated as a surrogate to evaluate the interplay effects for IMPT for lung cancer in the clinical setting. The interplay effects can be potentially mitigated by increasing the number of iso-layered re-scanning in each fraction delivery. PMID:25407877
Kardar, Laleh; Li, Yupeng; Li, Xiaoqiang; Li, Heng; Cao, Wenhua; Chang, Joe Y; Liao, Li; Zhu, Ronald X; Sahoo, Narayan; Gillin, Michael; Liao, Zhongxing; Komaki, Ritsuko; Cox, James D; Lim, Gino; Zhang, Xiaodong
2014-01-01
The primary aim of this study was to evaluate the impact of the interplay effects of intensity modulated proton therapy (IMPT) plans for lung cancer in the clinical setting. The secondary aim was to explore the technique of isolayered rescanning to mitigate these interplay effects. A single-fraction 4-dimensional (4D) dynamic dose without considering rescanning (1FX dynamic dose) was used as a metric to determine the magnitude of dosimetric degradation caused by 4D interplay effects. The 1FX dynamic dose was calculated by simulating the machine delivery processes of proton spot scanning on a moving patient, described by 4D computed tomography during IMPT delivery. The dose contributed from an individual spot was fully calculated on the respiratory phase that corresponded to the life span of that spot, and the final dose was accumulated to a reference computed tomography phase by use of deformable image registration. The 1FX dynamic dose was compared with the 4D composite dose. Seven patients with various tumor volumes and motions were selected for study. The clinical target volume (CTV) prescription coverage for the 7 patients was 95.04%, 95.38%, 95.39%, 95.24%, 95.65%, 95.90%, and 95.53% when calculated with the 4D composite dose and 89.30%, 94.70%, 85.47%, 94.09%, 79.69%, 91.20%, and 94.19% when calculated with the 1FX dynamic dose. For these 7 patients, the CTV coverage calculated by use of a single-fraction dynamic dose was 95.52%, 95.32%, 96.36%, 95.28%, 94.32%, 95.53%, and 95.78%, with a maximum monitor unit limit value of 0.005. In other words, by increasing the number of delivered spots in each fraction, the degradation of CTV coverage improved up to 14.6%. A single-fraction 4D dynamic dose without rescanning was validated as a surrogate to evaluate the interplay effects of IMPT for lung cancer in the clinical setting. The interplay effects potentially can be mitigated by increasing the amount of isolayered rescanning in each fraction delivery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
2014-06-15
Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder.more » The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior to SCP.« less
Maeda, Yoshikazu; Sato, Yoshitaka; Shibata, Satoshi; Bou, Sayuri; Yamamoto, Kazutaka; Tamamura, Hiroyasu; Fuwa, Nobukazu; Takamatsu, Shigeyuki; Sasaki, Makoto; Tameshige, Yuji; Kume, Kyo; Minami, Hiroki; Saga, Yusuke; Saito, Makoto
2018-05-01
We quantified interfractional movements of the prostate, seminal vesicles (SVs), and rectum during computed tomography (CT) image-guided proton therapy for prostate cancer and studied the range variation in opposed lateral proton beams. We analyzed 375 sets of daily CT images acquired throughout the proton therapy treatment of ten patients. We analyzed daily movements of the prostate, SVs, and rectum by simulating three image-matching strategies: bone matching, prostate center (PC) matching, and prostate-rectum boundary (PRB) matching. In the PC matching, translational movements of the prostate center were corrected after bone matching. In the PRB matching, we performed PC matching and correction along the anterior-posterior direction to match the boundary between the prostate and the rectum's anterior region. In each strategy, we evaluated systematic errors (Σ) and random errors (σ) by measuring the daily movements of certain points on each anatomic structure. The average positional deviations in millimeter of each point were determined by the Van Herk formula of 2.5Σ + 0.7σ. Using these positional deviations, we created planning target volumes of the prostate and SVs and analyzed the daily variation in the water equivalent length (WEL) from the skin surface to the target along the lateral beam directions using the density converted from the daily CT number. Based on this analysis, we designed prostate cancer treatment planning and evaluated the dose volume histograms (DVHs) for these strategies. The SVs' daily movements showed large variations over the superior-inferior direction, as did the rectum's anterior region. The average positional deviations of the prostate in the anterior, posterior, superior, inferior, and lateral sides (mm) in bone matching, PC matching, and PRB matching were (8.9, 9.8, 7.5, 3.6, 1.6), (5.6, 6.1, 3.5, 4.5, 1.9), and (8.6, 3.2, 3.5, 4.5, 1.9) (mm), respectively. Moreover, the ones of the SV tip were similarly (22.5, 15.5, 11.0, 7.6, 6.0), (11.8, 8.4, 7.8, 5.2, 6.3), and (9.9, 7.5, 7.8, 5.2, 6.3). PRB matching showed the smallest positional deviations at all portions except for the anterior portion of the prostate and was able to markedly reduce the positional deviations at the posterior portion. The averaged WEL variations at the distal and proximal sides of planning target volumes were estimated 7-9 mm and 4-6 mm, respectively, and showed the increasing of a few millimeters in PC and PRB matching compared to bone matching. In the treatment planning simulation, the DVH values of the rectum in PRB matching were reduced compared to those obtained with other matching strategies. The positional deviations for the prostate on the posterior side and the SVs were smaller by PRB matching than the other strategies and effectively reduced the rectal dose. 3D dose calculations indicate that PRB matching with CT image guidance may do a better job relative to other positioning methods to effectively reduce the rectal complications. The WEL variation was quite large, and the appropriate margin (approx. 10 mm) must be adapted to the proton range in an initial planning to maintain the coverage of target volumes throughout entire treatment. © 2018 American Association of Physicists in Medicine.
Jeyarajah, Jenny; Elam-Evans, Laurie D; Stokley, Shannon; Smith, Philip J; Singleton, James A
2016-09-01
Routine human papillomavirus (HPV) vaccination is recommended at 11 or 12 years by the Advisory Committee on Immunization Practices. National Immunization Survey-Teen data were analyzed to evaluate, among girls, coverage with one or more doses of HPV vaccination, missed opportunities for HPV vaccination, and potential achievable coverage before 13 years. Results were stratified by birth year cohorts. HPV vaccination coverage before 13 years (≥1 HPV dose) increased from 28.4% for girls born in 1995 to 46.8% for girls born in 2000. Among girls born during 1999-2000 who had not received HPV vaccination before 13 years (57.2%), 80.1% had at least 1 missed opportunity to receive HPV vaccination before 13 years. Opportunities to vaccinate for HPV at age 11 to 12 years are missed. Strategies are needed to decrease these missed opportunities for HPV vaccination. This can be facilitated by the administration of all vaccines recommended for adolescents at the same visit. © The Author(s) 2015.
Hoban, B; Larance, B; Gisev, N; Nielsen, S; Cohen, M; Bruno, R; Shand, F; Lintzeris, N; Hall, W; Farrell, M; Degenhardt, L
2015-11-01
The regular use of simple analgesics in addition to opioids such as paracetamol (or acetaminophen) is recommended for persistent pain to enhance analgesia. Few studies have examined the frequency and doses of paracetamol among people with chronic non-cancer pain including use above the recommended maximum daily dose. To assess (i) the prevalence of paracetamol use among people with chronic non-cancer pain prescribed opioids, (ii) assess the prevalence of paracetamol use above the recommended maximum daily dose and (iii) assess correlates of people who used paracetamol above the recommended maximum daily dose including: age, gender, income, education, pain severity and interference, use of paracetamol/opioid combination analgesics, total opioid dose, depression, anxiety, pain self-efficacy or comorbid substance use, among people prescribed opioids for chronic non-cancer pain. This study draws on baseline data collected for the Pain and Opioids IN Treatment (POINT) study and utilises data from 962 interviews and medication diaries. The POINT study is national prospective cohort of people with chronic non-cancer pain prescribed opioids. Participants were recruited from randomly selected pharmacies across Australia. Sixty-three per cent of the participants had used paracetamol in the past week (95% CI = 59.7-65.8). Among the paracetamol users 22% (95% CI = 19.3-24.6) had used paracetamol/opioid combination analgesics and 4.8% (95% CI = 3.6-6.3) had used paracetamol above the recommended maximum daily dose (i.e. > 4000 mg/day). Following binomial logistic regression (χ(2) = 25.98, df = 10, p = 0.004), people who had taken above the recommended maximum daily dose were less likely to have low income (AOR = 0.52, 95% CI = 0.27-0.99), more likely to use paracetamol/opioid combination analgesics (AOR = 2.01, 95% CI = 1.02-3.98) and more likely to take a higher opioid dose (AOR = 1.00, 95% CI = 1.00-1.01). The majority of people with chronic non-cancer pain prescribed opioids report using paracetamol appropriately. High income, use of paracetamol/opioid combination analgesics and higher opioid dose were independently associated with paracetamol use above the recommended maximum daily dose. © 2015 John Wiley & Sons Ltd.
Sahara, S; Sugimoto, M; Uotani, T; Ichikawa, H; Yamade, M; Iwaizumi, M; Yamada, T; Osawa, S; Sugimoto, K; Umemura, K; Miyajima, H; Furuta, T
2013-11-01
Twice-daily dosing of proton pump inhibitors (PPIs) is used to treat Helicobacter pylori or acid-related diseases, such as gastro-oesophageal reflux disease (GERD) refractory to standard dose of a PPI. Genetic polymorphisms of CYP2C19 are involved to different extents in the metabolism of four kinds of PPIs (omeprazole, lansoprazole, rabeprazole and esomeprazole) available in Japan. To compare acid-inhibitory effects of the four PPIs dosed twice daily in relation to CYP2C19 genotype. We performed 24-h pH monitoring studies on Day 7 of PPI treatment for 40 Japanese H. pylori-negative volunteers [15 CYP2C19 rapid metabolisers (RMs), 15 intermediate metabolisers (IMs) and 10 poor metabolisers (PMs)] using a randomised four-way crossover design: omeprazole 20 mg, esomeprazole 20 mg, lansoprazole 30 mg and rabeprazole 10 mg twice daily. Although median pH values with esomeprazole, omeprazole, lansoprazole and rabeprazole were 5.7 (3.5-7.2), 5.5 (2.4-7.2), 5.5 (3.7-7.3) and 5.2 (2.5-7.3), respectively (no statistically significant differences), CYP2C19 genotype-dependent differences were smaller for esomeprazole and rabeprazole compared with values for omeprazole and lansoprazole. In CYP2C19 RMs, the median pH with esomeprazole [5.4 (3.5-6.8)] was significantly higher than those with omeprazole [5.0 (2.4-5.9), P = 0.018], lansoprazole [4.7 (3.7-5.5), P = 0.017] or rabeprazole [4.8 (2.5-6.4), P = 0.002]. In IMs and PMs, the median pH was >5.0 independent of the PPI. In intermediate and rapid metabolisers of CYP2C19, PPIs dosed twice daily could attain sufficient acid suppression, while in CYP2C19 RMs, esomeprazole 20 mg twice daily caused the strongest inhibition of the four PPIs. Therefore, esomeprazole may be effective in Japanese population when dosed twice daily. © 2013 John Wiley & Sons Ltd.
Evans, Malkanthi; Antony, Joseph; Guthrie, Najla; Landes, Bernie; Aruoma, Okezie I
2018-01-01
The objective of this study was to investigate the effect of a broad-spectrum wellness beverage (Zeal Wellness [ZW]) on standardized measures of mood states, including overall feelings of vitality, in healthy, moderately stressed adults. A randomized, double-blind, placebo-controlled clinical trial was conducted among 99 eligible participants prescreened for moderate stress. Participants were randomized to one of four groups and received ZW once daily (1-dose-ZW; 14 g), ZW twice daily (2-dose-ZW; 28 g), placebo once daily (1-dose-placebo), or placebo twice daily (2-dose-placebo) for 4 weeks. A stress/vitality questionnaire assessed stress and the Profile of Moods (POMS) Questionnaire assessed vigor via mental/physical energy and global mood state. Safety was assessed by clinical chemistry, liver, kidney function, and anthropometric measures and adverse event reporting. Participants receiving 2-dose-ZW reported a 6.6% decrease in scores on POMS-Total Mood Disturbance (TMD; p < 0.05) and a 6.8% decrease in the anger-hostility mood state (p < 0.022) compared to the combined placebo group at day 29. The 2-dose-ZW provided a 12.8% greater improvement in POMS-TMD scores when compared to participants receiving 1-dose-ZW after 28 days of supplementation (p = 0.014). Within groups, there was a 22.4% and a 9.6% decrease in POMS-TMD scores in participants with 2-dose-ZW and 1-dose-ZW, respectively. In addition, participants receiving 2-dose-ZW showed significant improvements (p = 0.001) in the POMS t-score iceberg profile, which represented a shift to a more healthy profile. These data show that daily supplementation with 2-dose-ZW significantly decreased POMS-TMD scores and anger-hostility mood state and shifted the POMS iceberg profile to a healthy profile compared to the combined placebo, reflecting the functional benefit of rice-bran-fruit-vegetable extracts based beverage on health.
Gu, Jie-mei; Wang, Li; Lin, Hua; Chen, De-cai; Tang, Hai; Jin, Xiao-lan; Xia, Wei-bo; Hu, Yun-qiu; Fu, Wen-zhen; He, Jin-wei; Zhang, Hao; Wang, Chun; Yue, Hua; Hu, Wei-wei; Liu, Yu-juan; Zhang, Zhen-lin
2015-07-01
Oral risedronate is effective in the treatment of postmenopausal osteoporosis when administered daily, weekly, or monthly. In this 1-year, randomized, double-blind, multicenter study we compared the weekly 35-mg and daily 5-mg risedronate dosing regimens in the treatment of Chinese postmenopausal women with osteoporosis or osteopenia. Postmenopausal women with primary osteoporosis or osteopenia were randomly assigned to the weekly group or daily group (n=145 for each) that received oral risedronate 35 mg once a week or 5 mg daily, respectively, for 1 year. The subjects' bone mineral densities (BMDs), bone turnover markers (P1NP and β-CTX), new vertebral fractures, and adverse events were assessed at baseline and during the treatments. All subjects in the weekly group and 144 subjects in the daily group completed the study. The primary efficacy endpoint after 1 year, ie the mean percent changes in the lumbar spine BMD (95% CI) were 4.87% (3.92% to 5.81%) for the weekly group and 4.35% (3.31% to 5.39%) for the daily group. The incidences of clinical adverse events were 48.3% in the weekly group and 54.2% in the daily group. The weekly 35-mg and daily 5-mg risedronate dosing regimens during 1 year of follow-up show similar efficacy in improving BMDs and biochemical markers of bone turnover in Chinese postmenopausal women with osteoporosis or osteopenia. Moreover, the two dosing regimens exhibit similar safety and tolerability.
Newspaper Coverage of Intimate Partner Violence: Skewing Representations of Risk.
Carlyle, Kellie E; Slater, Michael D; Chakroff, Jennifer L
2008-03-01
How media portray intimate partner violence (IPV) has implications for public perceptions and social policy. Therefore, to better understand these portrayals, this study content analyzes a nationally representative sample of newspaper coverage of IPV over a two-year-period and compares this coverage to epidemiological data in order to examine the implications of the discrepancies between coverage and social reality. Stratified media outlets across the country were used to obtain a representative sample of daily newspapers based on their designated market areas, resulting in 395 IPV-related articles. Results show that newspaper framing of IPV tends to be heavily skewed toward episodic framing. In addition, there are significant differences between our data and epidemiological estimates, particularly in the coverage of homicide and use of alcohol and illegal drugs, which may skew public perceptions of risk. Implications for public perceptions and social policy are discussed.
The good news about smoking: how do U.S. newspapers cover tobacco issues?
Clegg Smith, Katherine; Wakefield, Melanie; Edsall, Elizabeth
2006-07-01
Media advocacy, or advocacy seeking media attention, can shape the policy environment, but the relationship between the nature of news media coverage of public health topics and policy outcomes has received insufficient research attention. We present the first large-scale study of news coverage of tobacco to focus on the potential impact for policy outcomes. Through our analysis of 9859 tobacco-focused news articles from ioo leading US daily newspapers between 2001 and 2003 we examined whether tobacco issues are newsworthy, and if so, whether coverage is favorable to policy progress. We found strong evidence for news-worthiness, and a tendency for coverage to highlight policy approaches to tackling tobacco. Coverage emphasized successes rather than setbacks, and newspaper editors lent support to tobacco control positions. There were, however, areas that did not garner sufficient attention to sustain a meaningful policy message. Our analysis of coverage of controversial issues also revealed areas where tobacco control efforts seem to pushing against ideological boundaries.
Vaccination coverage and its determinants among migrant children in Guangdong, China
2014-01-01
Background Guangdong province attracted more than 31 million migrants in 2010. But few studies were performed to estimate the complete and age-appropriate immunization coverage and determine risk factors of migrant children. Methods 1610 migrant children aged 12–59 months from 70 villages were interviewed in Guangdong. Demographic characteristics, primary caregiver’s knowledge and attitude toward immunization, and child’s immunization history were obtained. UTD and age-appropriate immunization rates for the following five vaccines and the overall series (1:3:3:3:1 immunization series) were assessed: one dose of BCG, three doses of DTP, OPV and HepB, one dose of MCV. Risk factors for not being UTD for the 1:3:3:3:1 immunization series were explored. Results For each antigen, the UTD immunization rate was above 71%, but the age-appropriate immunization rates for BCG, HepB, OPV, DPT and MCV were only 47.8%, 45.1%, 47.1%, 46.8% and 37.2%, respectively. The 1st dose was most likely to be delayed within them. For the 1:3:3:3:1 immunization series, the UTD immunization rate and age-appropriate immunization rate were 64.9% and 12.4% respectively. Several factors as below were significantly associated with UTD immunization. The primary caregiver’s determinants were their occupation, knowledge and attitude toward immunization. The child’s determinants were sex, Hukou, birth place, residential buildings and family income. Conclusions Alarmingly low immunization coverage of migrant children should be closely monitored by NIISS. Primary caregiver and child’s determinants should be considered when taking measures. Strategies to strengthen active out-reach activities and health education for primary caregivers needed to be developed to improve their immunization coverage. PMID:24568184
2014-01-01
Background Today it is unclear which technique for delivery of an additional boost after whole breast radiotherapy for breast conserved patients should be state of the art. We present a dosimetric comparison of different non-invasive treatment techniques for additional boost delivery. Methods For 10 different tumor bed localizations, 7 different non-invasive treatment plans were made. Dosimetric comparison of PTV-coverage and dose to organs at risk was performed. Results The Vero system achieved an excellent PTV-coverage and at the same time could minimize the dose to the organs at risk with an average near-maximum-dose (D2) to the heart of 0.9 Gy and the average volume of ipsilateral lung receiving 5 Gy (V5) of 1.5%. The TomoTherapy modalities delivered an average D2 to the heart of 0.9 Gy for the rotational and of 2.3 Gy for the static modality and an average V5 to the ipsilateral lung of 7.3% and 2.9% respectively. A rotational technique offers an adequate conformity at the cost of more low dose spread and a larger build-up area. In most cases a 2-field technique showed acceptable PTV-coverage, but a bad conformity. Electrons often delivered a worse PTV-coverage than photons, with the planning requirements achieved only in 2 patients and with an average D2 to the heart of 2.8 Gy and an average V5 to the ipsilateral lung of 5.8%. Conclusions We present advices which can be used as guidelines for the selection of the best individualized treatment. PMID:24467916
2014-01-01
Background The World Health Organization recommends African children receive two doses of measles containing vaccine (MCV) through routine programs or supplemental immunization activities (SIA). Moreover, children have an additional opportunity to receive MCV through outbreak response immunization (ORI) mass campaigns in certain contexts. Here, we present the results of MCV coverage by dose estimated through surveys conducted after outbreak response in diverse settings in Sub-Saharan Africa. Methods We included 24 household-based surveys conducted in six countries after a non-selective mass vaccination campaign. In the majority (22/24), the survey sample was selected using probability proportional to size cluster-based sampling. Others used Lot Quality Assurance Sampling. Results In total, data were collected on 60,895 children from 2005 to 2011. Routine coverage varied between countries (>95% in Malawi and Kirundo province (Burundi) while <35% in N’Djamena (Chad) in 2005), within a country and over time. SIA coverage was <75% in most settings. ORI coverage ranged from >95% in Malawi to 71.4% [95% CI: 68.9-73.8] in N’Djamena (Chad) in 2005. In five sites, >5% of children remained unvaccinated after several opportunities. Conversely, in Malawi and DRC, over half of the children eligible for the last SIA received a third dose of MCV. Conclusions Control pre-elimination targets were still not reached, contributing to the occurrence of repeated measles outbreak in the Sub-Saharan African countries reported here. Although children receiving a dose of MCV through outbreak response benefit from the intervention, ensuring that programs effectively target hard to reach children remains the cornerstone of measles control. PMID:24559281
Trends in Childhood Influenza Vaccination Coverage—U.S., 2004–2012
Lu, Peng-Jun; O'Halloran, Alissa; Meghani, Ankita; Grabowsky, Mark; Singleton, James A.
2014-01-01
Objective We compared estimates of childhood influenza vaccination coverage by health status, age, and racial/ethnic group across eight consecutive influenza seasons (2004 through 2012) based on two survey systems to assess trends in childhood influenza vaccination coverage in the U.S. Methods We used National Health Interview Survey (NHIS) and National Immunization Survey-Flu (NIS-Flu) data to estimate receipt of at least one dose of influenza vaccination among children aged 6 months to 17 years based on parental report. We computed estimates using Kaplan-Meier survival analysis methods. Results Based on the NHIS, overall influenza vaccination coverage with at least one dose of influenza vaccine among children increased from 16.2% during the 2004–2005 influenza season to 47.1% during the 2011–2012 influenza season. Children with health conditions that put them at high risk for complications from influenza had higher influenza vaccination coverage than children without these health conditions for all the seasons studied. In seven of the eight seasons studied, there were no significant differences in influenza vaccination coverage between non-Hispanic black and non-Hispanic white children. Influenza vaccination coverage estimates for children were slightly higher based on NIS-Flu data compared with NHIS data for the 2010–2011 and 2011–2012 influenza seasons (4.1 and 4.4 percentage points higher, respectively); both NIS-Flu and NHIS estimates had similar patterns of decreasing vaccination coverage with increasing age. Conclusions Although influenza vaccination coverage among children continued to increase, by the 2011–2012 influenza season, only slightly less than half of U.S. children were vaccinated against influenza. Much improvement is needed to ensure all children aged ≥6 months are vaccinated annually against influenza. PMID:25177053
Rivaroxaban in patients with a recent acute coronary syndrome.
Mega, Jessica L; Braunwald, Eugene; Wiviott, Stephen D; Bassand, Jean-Pierre; Bhatt, Deepak L; Bode, Christoph; Burton, Paul; Cohen, Marc; Cook-Bruns, Nancy; Fox, Keith A A; Goto, Shinya; Murphy, Sabina A; Plotnikov, Alexei N; Schneider, David; Sun, Xiang; Verheugt, Freek W A; Gibson, C Michael
2012-01-05
Acute coronary syndromes arise from coronary atherosclerosis with superimposed thrombosis. Since factor Xa plays a central role in thrombosis, the inhibition of factor Xa with low-dose rivaroxaban might improve cardiovascular outcomes in patients with a recent acute coronary syndrome. In this double-blind, placebo-controlled trial, we randomly assigned 15,526 patients with a recent acute coronary syndrome to receive twice-daily doses of either 2.5 mg or 5 mg of rivaroxaban or placebo for a mean of 13 months and up to 31 months. The primary efficacy end point was a composite of death from cardiovascular causes, myocardial infarction, or stroke. Rivaroxaban significantly reduced the primary efficacy end point, as compared with placebo, with respective rates of 8.9% and 10.7% (hazard ratio in the rivaroxaban group, 0.84; 95% confidence interval [CI], 0.74 to 0.96; P=0.008), with significant improvement for both the twice-daily 2.5-mg dose (9.1% vs. 10.7%, P=0.02) and the twice-daily 5-mg dose (8.8% vs. 10.7%, P=0.03). The twice-daily 2.5-mg dose of rivaroxaban reduced the rates of death from cardiovascular causes (2.7% vs. 4.1%, P=0.002) and from any cause (2.9% vs. 4.5%, P=0.002), a survival benefit that was not seen with the twice-daily 5-mg dose. As compared with placebo, rivaroxaban increased the rates of major bleeding not related to coronary-artery bypass grafting (2.1% vs. 0.6%, P<0.001) and intracranial hemorrhage (0.6% vs. 0.2%, P=0.009), without a significant increase in fatal bleeding (0.3% vs. 0.2%, P=0.66) or other adverse events. The twice-daily 2.5-mg dose resulted in fewer fatal bleeding events than the twice-daily 5-mg dose (0.1% vs. 0.4%, P=0.04). In patients with a recent acute coronary syndrome, rivaroxaban reduced the risk of the composite end point of death from cardiovascular causes, myocardial infarction, or stroke. Rivaroxaban increased the risk of major bleeding and intracranial hemorrhage but not the risk of fatal bleeding. (Funded by Johnson & Johnson and Bayer Healthcare; ATLAS ACS 2-TIMI 51 ClinicalTrials.gov number, NCT00809965.).
Karschner, Erin L; Schwope, David M; Schwilke, Eugene W; Goodwin, Robert S; Kelly, Deanna L; Gorelick, David A; Huestis, Marilyn A
2012-10-01
Determining time since last cannabis/Δ9-tetrahydrocannabinol (THC) exposure is important in clinical, workplace, and forensic settings. Mathematical models calculating time of last exposure from whole blood concentrations typically employ a theoretical 0.5 whole blood-to-plasma (WB/P) ratio. No studies previously evaluated predictive models utilizing empirically-derived WB/P ratios, or whole blood cannabinoid pharmacokinetics after subchronic THC dosing. Ten male chronic, daily cannabis smokers received escalating around-the-clock oral THC (40-120 mg daily) for 8 days. Cannabinoids were quantified in whole blood and plasma by two-dimensional gas chromatography-mass spectrometry. Maximum whole blood THC occurred 3.0 h after the first oral THC dose and 103.5h (4.3 days) during multiple THC dosing. Median WB/P ratios were THC 0.63 (n=196), 11-hydroxy-THC 0.60 (n=189), and 11-nor-9-carboxy-THC (THCCOOH) 0.55 (n=200). Predictive models utilizing these WB/P ratios accurately estimated last cannabis exposure in 96% and 100% of specimens collected within 1-5h after a single oral THC dose and throughout multiple dosing, respectively. Models were only 60% and 12.5% accurate 12.5 and 22.5h after the last THC dose, respectively. Predictive models estimating time since last cannabis intake from whole blood and plasma cannabinoid concentrations were inaccurate during abstinence, but highly accurate during active THC dosing. THC redistribution from large cannabinoid body stores and high circulating THCCOOH concentrations create different pharmacokinetic profiles than those in less than daily cannabis smokers that were used to derive the models. Thus, the models do not accurately predict time of last THC intake in individuals consuming THC daily. Published by Elsevier Ireland Ltd.
Knowledge of appropriate acetaminophen doses and potential toxicities in an adult clinic population.
Stumpf, Janice L; Skyles, Amy J; Alaniz, Cesar; Erickson, Steven R
2007-01-01
To evaluate the knowledge of appropriate doses and potential toxicities of acetaminophen and assess the ability to recognize products containing acetaminophen in an adult outpatient setting. Cross-sectional, prospective study. University adult general internal medicine (AGIM) clinic. 104 adult patients presenting to the clinic over consecutive weekdays in December 2003. Three-page, written questionnaire. Ability of patients to identify maximum daily doses and potential toxicities of acetaminophen and recognize products that contain acetaminophen. A large percentage of participants (68.3%) reported pain on a daily or weekly basis, and 78.9% reported use of acetaminophen in the past 6 months. Only 2 patients correctly identified the maximum daily dose of regular acetaminophen, and just 3 correctly identified the maximum dose of extra-strength acetaminophen. Furthermore, 28 patients were unsure of the maximum dose of either product. Approximately 63% of participants either had not received or were unsure whether information on the possible danger of high doses of acetaminophen had been previously provided to them. When asked to identify potential problems associated with high doses of acetaminophen, 43.3% of patients noted the liver would be affected. The majority of the patients (71.2%) recognized Tylenol as containing acetaminophen, but fewer than 15% correctly identified Vicodin, Darvocet, Tylox, Percocet, and Lorcet as containing acetaminophen. Although nearly 80% of this AGIM population reported recent acetaminophen use, their knowledge of the maximum daily acetaminophen doses and potential toxicities associated with higher doses was poor and appeared to be independent of education level, age, and race. This indicates a need for educational efforts to all patients receiving acetaminophen-containing products, especially since the ability to recognize multi-ingredient products containing acetaminophen was likewise poor.
Frost, Charles; Nepal, Sunil; Wang, Jessie; Schuster, Alan; Byon, Wonkyung; Boyd, Rebecca A; Yu, Zhigang; Shenker, Andrew; Barrett, Yu Chen; Mosqueda-Garcia, Rogelio; LaCreta, Frank
2013-01-01
Aim Apixaban is an oral factor Xa inhibitor approved for stroke prevention in atrial fibrillation and thromboprophylaxis in patients who have undergone elective hip or knee replacement surgery and under development for treatment of venous thromboembolism. This study examined the safety, pharmacokinetics and pharmacodynamics of multiple dose apixaban. Method This double-blind, randomized, placebo-controlled, parallel group, multiple dose escalation study was conducted in six sequential dose panels – apixaban 2.5, 5, 10 and 25 mg twice daily and 10 and 25 mg once daily– with eight healthy subjects per panel. Within each panel, subjects were randomized (3:1) to oral apixaban or placebo for 7 days. Subjects underwent safety assessments and were monitored for adverse events (AEs). Blood samples were taken to measure apixaban plasma concentration, international normalized ratio (INR), activated partial thromboplastin time (aPTT) and modified prothrombin time (mPT). Results Forty-eight subjects were randomized and treated (apixaban, n = 36; placebo, n = 12); one subject receiving 2.5 mg twice daily discontinued due to AEs (headache and nausea). No dose limiting AEs were observed. Apixaban maximum plasma concentration was achieved ∼3 h post-dose. Exposure increased approximately in proportion to dose. Apixaban steady-state concentrations were reached by day 3, with an accumulation index of 1.3–1.9. Peak : trough ratios were lower for twice daily vs. once daily regimens. Clotting times showed dose-related increases tracking the plasma concentration–time profile. Conclusion Multiple oral doses of apixaban were safe and well tolerated over a 10-fold dose range, with pharmacokinetics with low variability and concentration-related increases in clotting time measures. PMID:23451769
Namour, Florence; Diderichsen, Paul Matthias; Cox, Eugène; Vayssière, Béatrice; Van der Aa, Annegret; Tasset, Chantal; Van't Klooster, Gerben
2015-08-01
Filgotinib (GLPG0634) is a selective inhibitor of Janus kinase 1 (JAK1) currently in development for the treatment of rheumatoid arthritis and Crohn's disease. While less selective JAK inhibitors have shown long-term efficacy in treating inflammatory conditions, this was accompanied by dose-limiting side effects. Here, we describe the pharmacokinetics of filgotinib and its active metabolite in healthy volunteers and the use of pharmacokinetic-pharmacodynamic modeling and simulation to support dose selection for phase IIB in patients with rheumatoid arthritis. Two trials were conducted in healthy male volunteers. In the first trial, filgotinib was administered as single doses from 10 mg up to multiple daily doses of 200 mg. In the second trial, daily doses of 300 and 450 mg for 10 days were evaluated. Non-compartmental analysis was used to determine individual pharmacokinetic parameters for filgotinib and its metabolite. The overall pharmacodynamic activity for the two moieties was assessed in whole blood using interleukin-6-induced phosphorylation of signal-transducer and activator of transcription 1 as a biomarker for JAK1 activity. These data were used to conduct non-linear mixed-effects modeling to investigate a pharmacokinetic/pharmacodynamic relationship. Modeling and simulation on the basis of early clinical data suggest that the pharmacokinetics of filgotinib are dose proportional up to 200 mg, in agreement with observed data, and support that both filgotinib and its metabolite contribute to its pharmacodynamic effects. Simulation of biomarker response supports that the maximum pharmacodynamic effect is reached at a daily dose of 200 mg filgotinib. Based on these results, a daily dose range up to 200 mg has been selected for phase IIB dose-finding studies in patients with rheumatoid arthritis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, S; Guerrero, M; Zhang, B
Purpose: To implement a comprehensive non-measurement-based verification program for patient-specific IMRT QA Methods: Based on published guidelines, a robust IMRT QA program should assess the following components: 1) accuracy of dose calculation, 2) accuracy of data transfer from the treatment planning system (TPS) to the record-and-verify (RV) system, 3) treatment plan deliverability, and 4) accuracy of plan delivery. Results: We have implemented an IMRT QA program that consist of four components: 1) an independent re-calculation of the dose distribution in the patient anatomy with a commercial secondary dose calculation program: Mobius3D (Mobius Medical Systems, Houston, TX), with dose accuracy evaluationmore » using gamma analysis, PTV mean dose, PTV coverage to 95%, and organ-at-risk mean dose; 2) an automated in-house-developed plan comparison system that compares all relevant plan parameters such as MU, MLC position, beam iso-center position, collimator, gantry, couch, field size settings, and bolus placement, etc. between the plan and the RV system; 3) use of the RV system to check the plan deliverability and further confirm using “mode-up” function on treatment console for plans receiving warning; and 4) implementation of a comprehensive weekly MLC QA, in addition to routine accelerator monthly and daily QA. Among 1200 verifications, there were 9 cases of suspicious calculations, 5 cases of delivery failure, no data transfer errors, and no failure of weekly MLC QA. These 9 suspicious cases were due to the PTV extending to the skin or to heterogeneity correction effects, which would not have been caught using phantom measurement-based QA. The delivery failure was due to the rounding variation of MLC position between the planning system and RV system. Conclusion: A very efficient, yet comprehensive, non-measurement-based patient-specific QA program has been implemented and used clinically for about 18 months with excellent results.« less
Battista, Jerry J; Johnson, Carol; Turnbull, David; Kempe, Jeff; Bzdusek, Karl; Van Dyk, Jacob; Bauman, Glenn
2013-12-01
To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose-volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D95, tumor control probability, V70Gy, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies. The CTV D95 for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D95 values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D95 values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V(70Gy) and NTCP) remained within acceptable limits. The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning. Copyright © 2013 Elsevier Inc. All rights reserved.
Rampling, Roy; Sanson, Marc; Gorlia, Thiery; Lacombe, Denis; Lai, Christina; Gharib, Myriam; Taal, Walter; Stoffregen, Clemens; Decker, Rodney; van den Bent, Martin J.
2012-01-01
We report a phase 1 study to examine the safety and recommended dose of the oral protein kinase C-beta inhibitor (anti-angiogenic) enzastaurin in combination with single-agent temozolomide. The study was conducted in patients with recurrent glioblastoma or newly diagnosed disease that was not treatable with standard (chemo)radiotherapy. Patients were treated with standard dose temozolomide (200 mg/m2 for 5 days every 4 weeks) together with daily oral enzastaurin. Three dose levels of enzastaurin were investigated: 250 mg daily (OD), 500 mg OD, and 250 mg twice daily (BID). Dose-limiting toxicity was determined in the first 2 cycles, but treatment continued until limiting toxicity or disease progression was identified. Twenty-eight patients were enrolled. No dose-limiting toxicity was noted at 250 mg OD or 500 mg OD. However, at 250 mg BID, 2 dose-limiting episodes of thrombocytopenia were noted. The recommended dose for enzastaurin in combination with standard 4-weekly temozolomide is therefore 500 mg OD. The pharmacokinetics of enzastaurin in combination with temozolomide was evaluated. Temozolomide did not appear to effect enzastaurin exposures at the 250 mg or 500 mg OD dose levels. PMID:22291006
Herman, Ann E; Chinn, Leslie W; Kotwal, Shweta G; Murray, Elaine R; Zhao, Rui; Florero, Marilyn; Lin, Alyse; Moein, Anita; Wang, Rena; Bremer, Meire; Kokubu, Serika; Serone, Adrian P; Hanze, Eva L; Viberg, Anders; Morimoto, Alyssa M; Winter, Helen R; Katsumoto, Tamiko R
2018-06-01
GDC-0853 is a small molecule inhibitor of Bruton's tyrosine kinase (BTK) that is highly selective and noncovalent, leading to reversible binding. In double-blind, randomized, and placebo-controlled phase I healthy volunteer studies, GDC-0853 was well tolerated, with no dose-limiting adverse events (AEs) or serious AEs. The maximum tolerated dose was not reached during dose escalation (≤600 mg, single ascending dose (SAD) study; ≤250 mg twice daily (b.i.d.) and ≤500 mg once daily, 14-day multiple ascending dose (MAD) study). Plasma concentrations peaked 1-3 hours after oral administration and declined thereafter, with a steady-state half-life ranging from 4.2-9.9 hours. Independent assays demonstrated dose-dependent BTK target engagement. Based on pharmacokinetic/pharmacodynamic (PK/PD) simulations, a once-daily dosing regimen (e.g., 100 mg, q.d.) is expected to maintain a high level of BTK inhibition over the dosing interval. Taken together, the safety and PK/PD data support GDC-0853 evaluation in rheumatoid arthritis, lupus, and other autoimmune or inflammatory indications. © 2018 American Society for Clinical Pharmacology and Therapeutics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brock, K; Lee, C; Samuels, S
Purpose: Tools are now available to perform daily dose assessment in radiotherapy, however, guidance is lacking as to when to replan to limit increase in normal tissue dose. This work performs statistical analysis to provide guidance for when adaptive replanning may be necessary for head/neck (HN) patients. Methods: Planning CT and daily kVCBCT images for 50 HN patients treated with VMAT were retrospectively evaluated. Twelve of 50 patients were replanned due to anatomical changes noted over their RT course. Daily dose assessment was performed to calculate the variation between the planned and delivered dose for the 38 patients not replannedmore » and the patients replanned using their delivered plan. In addition, for the replanned patients, the dose that would have been delivered if the plan was not modified was also quantified. Deviations in dose were analyzed before and after replanning, the daily variations in patients who were not replanned assessed, and the predictive power of the deviation after 1, 5, and 15 fractions determined. Results: Dose deviations were significantly reduced following replanning, compared to if the original plan would have been delivered for the entire course. Early deviations were significantly correlated with total deviations (p<0.01). Using the criteria that a 10% increase in the final delivered dose indicates a replan may be needed earlier in the treatment course, the following guidelines can be made with a 90% specificity after the first 5 fractions: deviations of 7% in the mean dose to the inferior constrictors and 5% in the mean dose to the parotid glands and submandibular glands. No significant dose deviations were observed in any patients for the CTV -70Gy (max deviation 4%). Conclusions: A 5–7% increase in mean dose to normal tissues within the first 5 fractions strongly correlate to an overall deviatios in the delivered dose for HN patients. This work is funded in part by NIH 2P01CA059827-16.« less
Immunisation status and determinants of left-behind children aged 12-72 months in central China.
Ni, Z L; Tan, X D; Shao, H Y; Wang, Y
2017-07-01
Many parents move from rural China to urban areas in search of job opportunities, and leave their children behind to be raised by relatives. We aimed to assess the immunisation coverage, including the 1:3:3:3:1 vaccine series (one dose of Bacilli Chalmette-Guérin vaccine; three doses of live attenuated oral poliomyelitis vaccine; three doses of diphtheria, tetanus and pertussis combined; three doses of hepatitis B vaccine; and one dose of measles-containing vaccine), in children aged 12-72 months and identify the determinants of immunisation uptake among left-behind children in Hubei Province, Central China, in 2014. In this cross-sectional study using the World Health Organization's cluster sampling technique, we surveyed 1368 children from 44 villages in 11 districts of Hubei Province. The socio-demographic and vaccination status data were collected by interviewing primary caregivers using a semi-structured questionnaire and reviewing the immunisation cards of the children. Univariate and multivariate analyses were used to identify the determinants of complete vaccination and age-appropriate vaccination. For each dose of the five vaccines, the vaccination coverage in the left-behind and non-left-behind children was >90%; however, the age-appropriate vaccination coverage for each vaccine was lower in left-behind than in non-left-behind children. For the five vaccines, the fully vaccinated rate of left-behind children were lower than those of non-left-behind children (89·1%, 92·7%; P = 0·013) and age-appropriate immunisation rate of left-behind children were lower than those of non-left-behind children (65·7%, 79·9%; P < 0·001). After controlling for potential confounders, we found that the parenting pattern, annual household income and attitude of the primary caregiver towards vaccination significantly influenced the vaccination status of children. Moreover, we noted a relatively high prevalence of delayed vaccination among left-behind children. Hence, we believe that the age-appropriate immunisation coverage rate among left-behind children in rural areas should be further improved by delivering and sustaining primary care services.
Mutua, Martin Kavao; Kimani-Murage, Elizabeth; Ngomi, Nicholas; Ravn, Henrik; Mwaniki, Peter; Echoka, Elizabeth
2016-01-01
More efforts have been put in place to increase full immunization coverage rates in the last decade. Little is known about the levels and consequences of delaying or vaccinating children in different schedules. Vaccine effectiveness depends on the timing of its administration, and it is not optimal if given early, delayed or not given as recommended. Evidence of non-specific effects of vaccines is well documented and could be linked to timing and sequencing of immunization. This paper documents the levels of coverage, timing and sequencing of routine childhood vaccines. The study was conducted between 2007 and 2014 in two informal urban settlements in Nairobi. A total of 3856 children, aged 12-23 months and having a vaccination card seen were included in analysis. Vaccination dates recorded from the cards seen were used to define full immunization coverage, timeliness and sequencing. Proportions, medians and Kaplan-Meier curves were used to assess and describe the levels of full immunization coverage, vaccination delays and sequencing. The findings indicate that 67 % of the children were fully immunized by 12 months of age. Missing measles and third doses of polio and pentavalent vaccine were the main reason for not being fully immunized. Delays were highest for third doses of polio and pentavalent and measles. About 22 % of fully immunized children had vaccines in an out-of-sequence manner with 18 % not receiving pentavalent together with polio vaccine as recommended. Results show higher levels of missed opportunities and low coverage of routine childhood vaccinations given at later ages. New strategies are needed to enable health care providers and parents/guardians to work together to increase the levels of completion of all required vaccinations. In particular, more focus is needed on vaccines given in multiple doses (polio, pentavalent and pneumococcal conjugate vaccines).
Patel, Minal K; Capeding, Rosario Z; Ducusin, Joyce U; de Quiroz Castro, Maricel; Garcia, Luzviminda C; Hennessey, Karen
2014-09-03
Hepatitis B vaccination in the Philippines was introduced in 1992 to reduce the high burden of chronic hepatitis B virus (HBV) infection in the population; in 2007, a birth dose (HepB-BD) was introduced to decrease perinatal HBV transmission. Timely HepB-BD coverage, defined as doses given within 24h of birth, was 40% nationally in 2011. A first step in improving timely HepB-BD coverage is to ensure that all newborns born in health facilities are vaccinated. In order to assess ways of improving the Philippines' HepB-BD program, we evaluated knowledge, attitudes, and practices surrounding HepB-BD administration in health facilities. Teams visited selected government clinics, government hospitals, and private hospitals in regions with low reported HepB-BD coverage and interviewed immunization and maternity staff. HepB-BD coverage was calculated in each facility for a 3-month period in 2011. Of the 142 health facilities visited, 12 (8%) did not provide HepB-BD; seven were private hospitals and five were government hospitals. Median timely HepB-BD coverage was 90% (IQR 80%-100%) among government clinics, 87% (IQR 50%-97%) among government hospitals, and 50% (IQR 0%-90%) among private hospitals (p=0.02). The private hospitals were least likely to receive supervision (53% vs. 6%-31%, p=0.0005) and to report vaccination data to the national Expanded Programme on Immunization (36% vs. 96%-100%, p<0.0001). Private sector hospitals in the Philippines, which deliver 18% of newborns, had the lowest timely HepB-BD coverage. Multiple avenues exist to engage the private sector in hepatitis B prevention including through existing laws, newborn health initiatives, hospital accreditation processes, and raising awareness of the government's free vaccine program. Copyright © 2013 World Health Organization (WHO). Published by Elsevier Ltd.. All rights reserved.
Hu, Yu; Chen, Yaping; Wang, Ying; Liang, Hui
2018-04-03
This study aimed to evaluate the potential achievable coverage of the second dose of measles containing vaccine (MCV2) when the protocol of simultaneous administration of childhood vaccines was fully implemented. Risk factors for missed opportunity (MO) for simultaneous administration of MCV2 were also investigated. Children born from 1 January 2005 to 31 December 2014 and registered in Zhejiang provincial immunization information system were enrolled in this study. The MO of simultaneous administration of MCV2, the actual age-appropriate coverage (AAC) of MCV2 and the potentially achievable coverage (PAC) of MCV2 were evaluated and compared across different birth cohorts, by different socio-demographic variables. For the 2014 birth cohort, logistic regression model was used to detect the risk factors of MOs, from both socio-demographic and vaccination service providing aspects. Compared to the AAC, the PAC of MCV2 increased significantly from 2005 birth cohort to 2014 birth cohort (p<0.001), with a median of 12.7 percentage points. Higher birth order of children, resident children, higher maternal education background, higher socio-economic development level of resident areas, less frequent vaccination service, and shorter vaccination service time were significant risk factors of MO for simultaneous administration of MCV2, with all p-value < 0.05. The findings in this study suggest that fully utilization of all opportunities for simultaneous administration of all age-eligible vaccine doses at the same vaccination visit is critical for achieving the coverage target of 95% for MCV2. Future interventions focusing on the group with risk factors observed could substantially eliminate MOs for simultaneous administration of MCV2, further to improve the coverage of fully immunization of MCV, and finally achieve the goal of eliminating measles.
Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weksberg, David C.; Palmer, Matthew B.; Vu, Khoi N.
2012-11-01
Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme,more » and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.« less
SU-F-T-443: Quantification of Dosimetric Effects of Dental Metallic Implant On VMAT Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, C; Jiang, W; Feng, Y
Purpose: To evaluate the dosimetric impact of metallic implant that correlates with the size of targets and metallic implants and distance in between on volumetric-modulated arc therapy (VMAT) plans for head and neck (H&N) cancer patients with dental metallic implant. Methods: CT images of H&N cancer patients with dental metallic implant were used. Target volumes with different sizes and locations were contoured. Metal artifact regions excluding surrounding critical organs were outlined and assigned with CT numbers close to water (0HU). VMAT plans with half-arc, one-full-arc and two-full-arcs were constructed and same plans were applied to structure sets with and withoutmore » CT number assignment of metal artifact regions and compared. D95% was utilized to investigate PTV dose coverage and SNC Patient− Software was used for the analysis of dose distribution difference slice by slice. Results: For different targets sizes, variation of PTV dose coverage (Delta-D95%) with and without CT number replacement reduced with larger target volume for all half-arc, one-arc and two-arc VMAT plans even though there were no clinically significant differences. Additionally, there were no significant variations of the maximum percent difference (max.%diff) of dose distribution. With regard to the target location, Delta-D95% and max. %diff dropped with increasing distance between target and metallic implant. Furthermore, half-arc plans showed greater impact than one-arc plans, and two-arc plans had smallest influence for PTV dose coverage and dose distribution. Conclusion: The target size has less correlation of doseimetric impact than the target location relative to metallic implants. Plans with more arcs alleviate the dosimetric effect of metal artifact because of less contribution to the target dose from beams going through the regions with metallic artifacts. Incorrect CT number causes inaccurate dose distribution, therefore appropriately overwriting metallic artifact regions with reasonable CT numbers is recommended. More patient data are collected and under further analysis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
2015-06-15
Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. Themore » CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.« less
Immunisation coverage annual report, 2014.
Hull, Brynley P; Hendry, Alexandra J; Dey, Aditi; Beard, Frank H; Brotherton, Julia M; McIntyre, Peter B
2017-03-31
This 8th annual immunisation coverage report shows data for 2014 derived from the Australian Childhood Immunisation Register and the National Human Papillomavirus Vaccination Program Register. This report includes coverage data for 'fully immunised' and by individual vaccines at standard age milestones and timeliness of receipt at earlier ages according to Indigenous status. Overall, 'fully immunised' coverage has been mostly stable at the 12- and 24-month age milestones since late 2003, but at 60 months of age, it has increased by more than 10 percentage points since 2009. As in previous years, coverage for 'fully immunised' at 12 months of age among Indigenous children was 3.7% lower than for non-Indigenous children overall, varying from 6.9 percentage points in Western Australia to 0.3 of a percentage point in the Australian Capital Territory. In 2014, 73.4% of Australian females aged 15 years had 3 documented doses of human papillomavirus vaccine (jurisdictional range 67.7% to 77.4%), and 82.7% had at least 1 dose, compared with 71.4% and 81.5%, respectively, in 2013. The disparity in on-time vaccination between Indigenous and non-Indigenous children in 2014 diminished progressively from 20.2% for vaccines due by 12 months to 11.5% for those due by 24 months and 3.0% at 60 months of age.
Msyamboza, Kelias Phiri; Mwagomba, Beatrice Matanje; Valle, Moussa; Chiumia, Hastings; Phiri, Twambilire
2017-06-26
Cervical cancer is a major public health problem in Malawi. The age-standardized incidence and mortality rates are estimated to be 75.9 and 49.8 per 100,000 population, respectively. The availability of the human papillomavirus (HPV) vaccine presents an opportunity to reduce the morbidity and mortality associated with cervical cancer. In 2013, the country introduced a school-class-based HPV vaccination pilot project in two districts. The aim of this study was to evaluate HPV vaccine coverage, lessons learnt and challenges identified during the first three years of implementation. This was an evaluation of the HPV vaccination project targeting adolescent girls aged 9-13 years conducted in Malawi from 2013 to 2016. We analysed programme data, supportive supervision reports and minutes of National HPV Task Force meetings to determine HPV vaccine coverage, reasons for partial or no vaccination and challenges. Administrative coverage was validated using a community-based coverage survey. A total of 26,766 in-school adolescent girls were fully vaccinated in the two pilot districts during the first three years of the programme. Of these; 2051 (7.7%) were under the age of 9 years, 884 (3.3%) were over the age of 13 years, and 23,831 (89.0%) were aged 9-13 years (the recommended age group). Of the 765 out-of-school adolescent girls aged 9-13 who were identified during the period, only 403 (52.7%) were fully vaccinated. In Zomba district, the coverage rates of fully vaccinated were 84.7%, 87.6% and 83.3% in year 1, year 2 and year 3 of the project, respectively. The overall coverage for the first three years was 82.7%, and the dropout rate was 7.7%. In Rumphi district, the rates of fully vaccinated coverage were 90.2% and 96.2% in year 1 and year 2, respectively, while the overall coverage was 91.3%, and the dropout rate was 4.9%. Administrative (facility-based) coverage for the first year was validated using a community-based cluster coverage survey. The majority of the coverage results were statistically similar, except for in Rumphi district, where community-based 3-dose coverage was higher than the corresponding administrative-coverage (94.2% vs 90.2%, p < 0.05), and overall (in both districts), facility-based 1-dose coverage was higher than the corresponding community-based (94.6% vs 92.6%, p < 0.05). Transferring out of the district, dropping out of school and refusal were some of the reasons for partial or no uptake of the vaccine. In Malawi, the implementation of a school-class-based HPV vaccination strategy was feasible and produced high (>80%) coverage. However, this strategy may be associated with the vaccination of under- and over-aged adolescent girls who are outside of the vaccine manufacturer's stipulated age group (9-13 years). The health facility-based coverage for out-of-school adolescent girls produced low coverage, with only half of the target population being fully vaccinated. These findings highlight the need to assess the immunogenicity associated with the administration of a two-dose schedule to adolescent girls younger or older than 9-13 years and effectiveness of health facility-based strategy before rolling out the programme.
Mwamba, Guillaume Ngoie; Yoloyolo, Norbert; Masembe, Yolande; Nsambu, Muriel Nzazi; Nzuzi, Cathy; Tshekoya, Patrice; Dah, Barthelemy; Kaya, Guylain
2017-01-01
Introduction Vaccination coverage of the first dose of diphtheria-tetanus-pertussis-hepatitis B-Haemophilus influenza type b (pentavalent) vaccine for the City-Province of Kinshasain the years 2012 – 2014 wasbelow the national objective of 92%, with coverage less than 80% reported in 12 of the 35 health zones (HZ). The purpose of this study was to discern potential contributing factors to low vaccination coverage in Kinshasa. Methods We conducted a multi-stage cluster household study of children 6 – 11 months in households residing in their current neighborhood for at least 3 months in the 12 high risk HZ in Kinshasa. Additional information on vaccination status of the children was collected at the health facility. Results Of the 1,513 households with a child 6-11 months old, 81% were eligible and participated. Among the 1224 children surveyed, 96% had received the first dose of pentavalent vaccine; 84% had received the third dose; and 71% had received all recommended vaccines for their age. Longer travel time to get to health facility (p=0.04) and shorter length of residence in the neighborhood (p=0.04) showed significant differences in relation to incomplete vaccination. Forty percent of children received their most recent vaccination in a facility outside of their HZ of residence. Conclusion This survey found vaccination coverage in 12 HZs in Kinshasa was higher than estimates derived from administrative reports. The large percentage of children vaccinated outside of their HZ of residence demonstrates the challenge to use of the Reaching Every District strategy in urban areas. PMID:29296142
Progress Toward Measles Elimination - Western Pacific Region, 2013-2017.
Hagan, José E; Kriss, Jennifer L; Takashima, Yoshihiro; Mariano, Kayla Mae L; Pastore, Roberta; Grabovac, Varja; Dabbagh, Alya J; Goodson, James L
2018-05-04
In 2005, the Regional Committee for the World Health Organization (WHO) Western Pacific Region (WPR)* established a goal for measles elimination † by 2012 (1). To achieve this goal, the 37 WPR countries and areas implemented the recommended strategies in the WPR Plan of Action for Measles Elimination (2) and the Field Guidelines for Measles Elimination (3). The strategies include 1) achieving and maintaining ≥95% coverage with 2 doses of measles-containing vaccine (MCV) through routine immunization services and supplementary immunization activities (SIAs), when required; 2) conducting high-quality case-based measles surveillance, including timely and accurate testing of specimens to confirm or discard suspected cases and detect measles virus for genotyping and molecular analysis; and 3) establishing and maintaining measles outbreak preparedness to ensure rapid response and appropriate case management. This report updates the previous report (4) and describes progress toward measles elimination in WPR during 2013-2017. During 2013-2016, estimated regional coverage with the first MCV dose (MCV1) decreased from 97% to 96%, and coverage with the routine second MCV dose (MCV2) increased from 91% to 93%. Eighteen (50%) countries achieved ≥95% MCV1 coverage in 2016. Seven (39%) of 18 nationwide SIAs during 2013-2017 reported achieving ≥95% administrative coverage. After a record low of 5.9 cases per million population in 2012, measles incidence increased during 2013-2016 to a high of 68.9 in 2014, because of outbreaks in the Philippines and Vietnam, as well as increased incidence in China, and then declined to 5.2 in 2017. To achieve measles elimination in WPR, additional measures are needed to strengthen immunization programs to achieve high population immunity, maintain high-quality surveillance for rapid case detection and confirmation, and ensure outbreak preparedness and prompt response to contain outbreaks.
Maina, Isabella; Wanjala, Pepela; Soti, David; Kipruto, Hillary; Droti, Benson; Boerma, Ties
2017-10-01
To develop a systematic approach to obtain the best possible national and subnational statistics for maternal and child health coverage indicators from routine health-facility data. Our approach aimed to obtain improved numerators and denominators for calculating coverage at the subnational level from health-facility data. This involved assessing data quality and determining adjustment factors for incomplete reporting by facilities, then estimating local target populations based on interventions with near-universal coverage (first antenatal visit and first dose of pentavalent vaccine). We applied the method to Kenya at the county level, where routine electronic reporting by facilities is in place via the district health information software system. Reporting completeness for facility data were well above 80% in all 47 counties and the consistency of data over time was good. Coverage of the first dose of pentavalent vaccine, adjusted for facility reporting completeness, was used to obtain estimates of the county target populations for maternal and child health indicators. The country and national statistics for the four-year period 2012/13 to 2015/16 showed good consistency with results of the 2014 Kenya demographic and health survey. Our results indicated a stagnation of immunization coverage in almost all counties, a rapid increase of facility-based deliveries and caesarean sections and limited progress in antenatal care coverage. While surveys will continue to be necessary to provide population-based data, web-based information systems for health facility reporting provide an opportunity for more frequent, local monitoring of progress, in maternal and child health.
A case study of IMRT planning (Plan B) subsequent to a previously treated IMRT plan (Plan A)
NASA Astrophysics Data System (ADS)
Cao, F.; Leong, C.; Schroeder, J.; Lee, B.
2014-03-01
Background and purpose: Treatment of the contralateral neck after previous ipsilateral intensity modulated radiation therapy (IMRT) for head and neck cancer is a challenging problem. We have developed a technique that limits the cumulative dose to the spinal cord and brainstem while maximizing coverage of a planning target volume (PTV) in the contralateral neck. Our case involves a patient with right tonsil carcinoma who was given ipsilateral IMRT with 70Gy in 35 fractions (Plan A). A left neck recurrence was detected 14 months later. The patient underwent a neck dissection followed by postoperative left neck radiation to a dose of 66 Gy in 33 fractions (Plan B). Materials and Methods: The spinal cord-brainstem margin (SCBM) was defined as the spinal cord and brainstem with a 1.0 cm margin. Plan A was recalculated on the postoperative CT scan but the fluence outside of SCBM was deleted. A further modification of Plan A resulted in a base plan that was summed with Plan B to evaluate the cumulative dose received by the spinal cord and brainstem. Plan B alone was used to evaluate for coverage of the contralateral neck PTV. Results: The maximum cumulative doses to the spinal cord with 0.5cm margin and brainstem with 0.5cm margin were 51.96 Gy and 45.60 Gy respectively. For Plan B, 100% of the prescribed dose covered 95% of PTVb1. Conclusion: The use of a modified ipsilateral IMRT plan as a base plan is an effective way to limit the cumulative dose to the spinal cord and brainstem while enabling coverage of a PTV in the contralateral neck.
Sachdeva, Sandeep; Datta, Utsuk
2009-01-01
Objective: To determine vitamin A-first dose supplement coverage in children aged 12–23 months and to find out its correlates with selected variables. Materials and Methods: The 30-cluster sampling technique based on probability proportional to size advocated by the World Health Organization was used to assess vitamin A-first dose supplement amongst 210 children in the age group of 12–23 months residing in slums of a randomly selected municipal zone of Delhi during October to November 2005. Results: Only 79 (37.6%) children out of 210 had received vitamin A-first dose supplement. Further analysis of 79 children was carried out with regard to selected variables like religion, gender, birth order, place of birth, immunization status and literacy of mother. These analyses showed that 71 (89.9%) were Hindu and eight (10.1%) were non-Hindu (P = 0.04). Nearly 44 (55.7%) males and 35 (44.3%) females had received vitamin A (P = 0.74). The proportion of children born in a health institution who received first dose (57%) of vitamin A supplementation was significantly higher than of those who were born at home (43%) (P < 0.001). Similarly, higher proportion of children with birth order-one (48.1%) in comparison to birth order-three or above (26.6%) received vitamin A (P < 0.001). Thirty children though fully immunized for vaccine-preventable disease up to the age-of-one year had not received vitamin A-first dose supplement, suggesting that an opportunity had been missed. The association between receipt of vitamin A by the child and literacy status of mother was found to be significant (P < 0.001). Conclusion: The study reflects low coverage of Vitamin A supplement. PMID:19574699
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levin, Daphne; Menhel, Janna; Alezra, Dror
2008-01-01
We compared 9-field, equispaced intensity modulated radiation therapy (IMRT), 4- to 5-field, directionally optimized IMRT, and 3-dimensional (3D) noncoplanar planning approaches for tumors of the maxillary sinus. Ten patients were planned retrospectively to compare the different treatment techniques. Prescription doses were 60 to 70 Gy. Critical structures contoured included optic nerves and chiasm, lacrimal glands, lenses, and retinas. As an aid for plan assessment, we introduced a new tool: Critical Organ Scoring Index (COSI), which allows quantitative evaluation of the tradeoffs between target coverage and critical organ sparing. This index was compared with other, commonly used conformity indices. For amore » reliable assessment of both tumor coverage and dose to critical organs in the different planning techniques, we introduced a 2D, graphical representation of COSI vs. conformity index (CI). Dose-volume histograms and mean, maximum, and minimum organ doses were also compared. IMRT plans delivered lower doses to ipsilateral structures, but were unable to spare them. 3D plans delivered less dose to contralateral structures, and were more homogeneous, as well. Both IMRT approaches gave similar results. In cases where choice of optimal plan was difficult, the novel 2D COSI-CI representation gave an accurate picture of the tradeoffs between target coverage and organ sparing, even in cases where other conformity indices failed. Due to their unique anatomy, maxillary sinus tumors may benefit more from a noncoplanar approach than from IMRT. The new graphical representation proposed is a quick, visual, reliable tool, which may facilitate the physician's choice of best treatment plan for a given patient.« less
Zhao, Dan; Ma, Rui; Zhou, Tao; Yang, Fan; Wu, Jin; Sun, Hao; Liu, Fang; Lu, Li; Li, Xiaomei; Zuo, Shuyan; Yao, Wei; Yin, Jian
2017-12-15
When included in a sequential polio vaccination schedule, inactivated polio vaccine (IPV) reduces the risk for vaccine-associated paralytic poliomyelitis (VAPP), a rare adverse event associated with receipt of oral poliovirus vaccine (OPV). During January 2014, the World Health Organization (WHO) recommended introduction of at least 1 IPV dose into routine immunization schedules in OPV-using countries (1). The Polio Eradication and Endgame Strategic Plan 2013-2018 recommended completion of IPV introduction in 2015 and globally synchronized withdrawal of OPV type 2 in 2016 (2). Introduction of 1 dose of IPV into Beijing's Expanded Program on Immunization (EPI) on December 5, 2014 represented China's first province-wide IPV introduction. Coverage with the first dose of polio vaccine was maintained from 96.2% to 96.9%, similar to coverage with the first dose of diphtheria and tetanus toxoids and pertussis vaccine (DTP) (96.5%-97.2%); the polio vaccine dropout rate (the percentage of children who received the first dose of polio vaccine but failed to complete the series) was 1.0% in 2015 and 0.4% in 2016. The use of 3 doses of private-sector IPV per child decreased from 18.1% in 2014, to 17.4% in 2015, and to 14.8% in 2016. No cases of VAPP were identified during 2014-2016. Successful introduction of IPV into the public sector EPI program was attributed to comprehensive planning, preparation, implementation, robust surveillance for adverse events after immunization (AEFI), and monitoring of vaccination coverage. This evaluation provided information that helped contribute to the expansion of IPV use in China and in other OPV-using countries.
WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsang, H; Kamerling, CP; Ziegenhein, P
2016-06-15
Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reducedmore » OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less
Comparison of Dose Decrement from Intrafraction Motion for Prone and Supine Prostate Radiotherapy
Olsen, Jeffrey; Parikh, Parag J; Watts, Michael; Noel, Camille E; Baker, Kenneth W; Santanam, Lakshmi; Michalski, Jeff M
2012-01-01
Background and Purpose Dose effects of intrafraction motion during prone prostate radiotherapy are unknown. We compared prone and supine treatment using real-time tracking data to model dose coverage. Material and Methods Electromagnetic tracking data was analyzed for 10 patients treated prone, and 15 treated supine, with IMRT for localized prostate cancer. Plans were generated using 0, 3, and 5 mm PTV expansions. Manual beam-hold interventions were applied to reposition the patient when translations exceeded a predetermined threshold. A custom software application (SWIFTER) used intrafraction tracking data acquired during beam-on to model delivered prostate dose, by applying rigid body transformations to the prostate structure contoured at simulation within the planned dose cloud. The delivered minimum prostate dose as a percentage of planned dose (Dmin%), and prostate volume covered by the prescription dose as a percentage of the planned volume (VRx%) were compared for prone and supine treatment. Results Dmin% was reduced for prone treatment for 0 (p=0.02) and 3 mm (p=0.03) PTV margins. VRx% was reduced for prone treatment only for 0 mm margins (p=0.002). No significant differences were found using 5 mm margins. Conclusions Intrafraction motion has a greater impact on target coverage for prone compared to supine prostate radiotherapy. PTV margins of 3 mm or less correlate with a significant decrease in delivered dose for prone treatment. PMID:22809590
Comparison of dose decrement from intrafraction motion for prone and supine prostate radiotherapy.
Olsen, Jeffrey R; Parikh, Parag J; Watts, Michael; Noel, Camille E; Baker, Kenneth W; Santanam, Lakshmi; Michalski, Jeff M
2012-08-01
Dose effects of intrafraction motion during prone prostate radiotherapy are unknown. We compared prone and supine treatment using real-time tracking data to model dose coverage. Electromagnetic tracking data were analyzed for 10 patients treated prone, and 15 treated supine, with IMRT for localized prostate cancer. Plans were generated using 0 mm, 3 mm, and 5mm PTV expansions. Manual beam-hold interventions were applied to reposition the patient when translations exceeded a predetermined threshold. A custom software application (SWIFTER) used intrafraction tracking data acquired during beam-on model delivered prostate dose, by applying rigid body transformations to the prostate structure contoured at simulation within the planned dose cloud. The delivered minimum prostate dose as a percentage of planned dose (Dmin%), and prostate volume covered by the prescription dose as a percentage of the planned volume (VRx%) were compared for prone and supine treatment. Dmin% was reduced for prone treatment for 0 (p=0.02) and 3 mm (p=0.03) PTV margins. VRx% was reduced for prone treatment only for 0mm margins (p=0.002). No significant differences were found using 5 mm margins. Intrafraction motion has a greater impact on target coverage for prone compared to supine prostate radiotherapy. PTV margins of 3 mm or less correlate with a significant decrease in delivered dose for prone treatment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Liu, Chenbin; Schild, Steven E; Chang, Joe Y; Liao, Zhongxing; Korte, Shawn; Shen, Jiajian; Ding, Xiaoning; Hu, Yanle; Kang, Yixiu; Keole, Sameer R; Sio, Terence T; Wong, William W; Sahoo, Narayan; Bues, Martin; Liu, Wei
2018-06-01
To investigate how spot size and spacing affect plan quality, robustness, and interplay effects of robustly optimized intensity modulated proton therapy (IMPT) for lung cancer. Two robustly optimized IMPT plans were created for 10 lung cancer patients: first by a large-spot machine with in-air energy-dependent large spot size at isocenter (σ: 6-15 mm) and spacing (1.3 σ), and second by a small-spot machine with in-air energy-dependent small spot size (σ: 2-6 mm) and spacing (5 mm). Both plans were generated by optimizing radiation dose to internal target volume on averaged 4-dimensional computed tomography scans using an in-house-developed IMPT planning system. The dose-volume histograms band method was used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effects with randomized starting phases for each field per fraction. Patient anatomy voxels were mapped phase-to-phase via deformable image registration, and doses were scored using in-house-developed software. Dose-volume histogram indices, including internal target volume dose coverage, homogeneity, and organs at risk (OARs) sparing, were compared using the Wilcoxon signed-rank test. Compared with the large-spot machine, the small-spot machine resulted in significantly lower heart and esophagus mean doses, with comparable target dose coverage, homogeneity, and protection of other OARs. Plan robustness was comparable for targets and most OARs. With interplay effects considered, significantly lower heart and esophagus mean doses with comparable target dose coverage and homogeneity were observed using smaller spots. Robust optimization with a small spot-machine significantly improves heart and esophagus sparing, with comparable plan robustness and interplay effects compared with robust optimization with a large-spot machine. A small-spot machine uses a larger number of spots to cover the same tumors compared with a large-spot machine, which gives the planning system more freedom to compensate for the higher sensitivity to uncertainties and interplay effects for lung cancer treatments. Copyright © 2018 Elsevier Inc. All rights reserved.
Anon, Jack B
2004-08-02
Acute bacterial rhinosinusitis (ABRS) is a secondary bacterial infection of the nose and paranasal sinuses, usually preceded by a viral upper respiratory infection or allergy, with symptoms that have not improved after 10 days or that have worsened after 5 to 7 days. Streptococcus pneumoniae and Haemophilus influenzae are the most common causes of ABRS in adults. Increasing rates of antimicrobial resistance among S. pneumoniae and beta-lactamase production among H. influenzae are formidable challenges to the successful treatment of infections caused by these organisms. To this end, various formulations of amoxicillin-clavulanate have been developed, the most recent of which is pharmacokinetically enhanced and provides a total daily dose of 4,000 mg of amoxicillin and 250 mg of clavulanate. This formulation has been shown to be safe and effective in the treatment of infections caused by penicillin-resistant S. pneumoniae (minimum inhibitory concentration 2 microg/mL); the clavulanate component provides adequate coverage of beta-lactamase-producing pathogens.
Kimoto, Aishi; Tanaka, Makoto; Nozaki, Kazutoshi; Mori, Masamichi; Fukushima, Shinji; Mori, Hiroshi; Shiroya, Tsutomu; Nakamura, Toshitaka
2013-07-01
This study examined and compared the effects of four-week intermittent and daily administrations of minodronic acid, a highly potent nitrogen-containing bisphosphonate, on bone mineral density (BMD), bone strength, bone turnover, and histomorphometry on established osteopenia in ovariectomized (OVX) rats. Fourteen-week-old female F344 rats were OVX or sham-operated. At 12 weeks post surgery, minodronic acid was orally administered once every 4 weeks at 0.2, 1, and 5 mg/kg and once daily at 0.006, 0.03, and 0.15 mg/kg for 12 months. The total dosing amount was comparable between the two dosing regimens. The levels of urinary deoxypyridinoline and serum osteocalcin were measured to assess bone turnover. BMD as assessed via dual-energy X-ray absorptiometry, bone structure and dynamical changes in vertebral trabecula and biomechanical properties were measured ex vivo at 12 months to assess bone content and material properties. Minodronic acid dose-dependently ameliorated the decrease in BMD of lumbar vertebrae and the femur in both treatment regimens similarly. Minodronic acid suppressed elevated urinary levels of deoxypyridinoline, a bone resorption marker, and reduced the serum levels of osteocalcin, a bone formation marker. In the mechanical test at 12 months of treatment, minodronic acid dose-dependently ameliorated the reduction in bone strength in femur and vertebral body. There is no significant difference in parameters between the two regimens except maximal load of lower doses in lumbar vertebral body and absorption energy of middle doses in femur. With these parameters with significant differences, values of the intermittent regimen were significantly lower than that of daily repeated regimen. Bone histomorphometric analysis of the lumbar vertebral body showed that minodronic acid significantly ameliorated the decrease in bone mass, trabecular thickness and number, and the increase in trabecular separation, bone resorption indices (Oc.S/BS and N.Oc/BS), and bone formation indices (BFR/BS, MAR and OV/BV) in both regimens. Minodronic acid suppressed OVX-induced increases in bone turnover at the tissue level and ameliorated all structural indices, thereby improving the deterioration of bone quality under osteoporotic disease conditions regardless of the regimen. In conclusion, a four-week intermittent treatment of minodronic acid suppressed increased bone resorption as daily treatment when considering the total administered dose in OVX rats with established osteopenia. The improvement of microarchitectural destruction in low dose of intermittent treatment was weaker than that observed in a daily repeated regimen; however the effects of high and middle doses of intermittent treatment were equivalent to that observed in daily repeated regimen accompanied by sufficient bone resorption inhibition in rats. These findings suggest that minodronic acid at an appropriate dose in an intermittent regimen may be as clinically useful in osteoporosis therapy as in daily treatment. Copyright © 2013 Elsevier Inc. All rights reserved.
Admiraal, Marjan A; Schuring, Danny; Hurkmans, Coen W
2008-01-01
The purpose of this study was to determine the 4D accumulated dose delivered to the CTV in stereotactic radiotherapy of lung tumours, for treatments planned on an average CT using an ITV derived from the Maximum Intensity Projection (MIP) CT. For 10 stage I lung cancer patients, treatment plans were generated based on 4D-CT images. From the 4D-CT scan, 10 time-sorted breathing phases were derived, along with the average CT and the MIP. The ITV with a margin of 0mm was used as a PTV to study a worst case scenario in which the differences between 3D planning and 4D dose accumulation will be largest. Dose calculations were performed on the average CT. Dose prescription was 60Gy to 95% of the PTV, and at least 54Gy should be received by 99% of the PTV. Plans were generated using the inverse planning module of the Pinnacle(3) treatment planning system. The plans consisted of nine coplanar beams with two segments each. After optimisation, the treatment plan was transferred to all breathing phases and the delivered dose per phase was calculated using an elastic body spline model available in our research version of Pinnacle (8.1r). Then, the cumulative dose to the CTV over all breathing phases was calculated and compared to the dose distribution of the original treatment plan. Although location, tumour size and breathing-induced tumour movement varied widely between patients, the PTV planning criteria could always be achieved without compromising organs at risk criteria. After 4D dose calculations, only very small differences between the initial planned PTV coverage and resulting CTV coverage were observed. For all patients, the dose delivered to 99% of the CTV exceeded 54Gy. For nine out of 10 patients also the criterion was met that the volume of the CTV receiving at least the prescribed dose was more than 95%. When the target dose is prescribed to the ITV (PTV=ITV) and dose calculations are performed on the average CT, the cumulative CTV dose compares well to the planned dose to the ITV. Thus, the concept of treatment plan optimisation and evaluation based on the average CT and the ITV is a valid approach in stereotactic lung treatment. Even with a zero ITV to PTV margin, no significantly different dose coverage of the CTV arises from the breathing motion induced dose variation over time.
Petitpretz, Patrick; Chidiac, Christian; Soriano, Francisco; Garau, Javier; Stevenson, Katharine; Rouffiac, Elisabeth
2002-08-01
This double-blind, double-dummy, parallel-group study was designed to show that a pharmacokinetically enhanced formulation of oral amoxycillin-clavulanate (16:1, 2000/125 mg), twice daily, is at least as effective clinically and microbiologically as oral amoxycillin-clavulanate 1000/125 mg, three times daily, in the 10 day treatment of community-acquired pneumonia (CAP) in adults. The pharmacokinetically enhanced formulation is designed to provide higher serum concentrations of amoxycillin for a longer period than standard dosing to achieve coverage of Streptococcus pneumoniae isolates with amoxycillin-clavulanic acid minimum inhibitory concentrations (MICs) up to and including 4 mg/l. A total of 344 patients with CAP from 77 centres received amoxycillin-clavulanate 2000/125 mg twice daily for 10 days (169 patients) or amoxycillin-clavulanate 1000/125 mg three times daily for 10 days (175 patients). The most common pathogen isolated was S. pneumoniae (52.3% of patients, amoxycillin-clavulanate 2000/125 mg group; 46.8% of patients, amoxycillin-clavulanate 1000/125 mg group). In the clinical per-protocol (PP) population at test of cure (days 18-39), the clinical success rate in the amoxycillin-clavulanate 2000/125 mg group was at least as good as in the amoxycillin-clavulanate 1000/125 mg group (91.5 and 93.0%, respectively; 95% CI, -8.3, 5.4). The radiological and bacteriological success rates at test of cure for the PP populations were 92.4 and 90.6% in the amoxycillin-clavulanate 2000/125 mg group and 93.9 and 84.4% in the amoxycillin-clavulanate 1000/125 mg group, respectively. The clinical, bacteriological and radiological success rates at the end of therapy (days 11-17) for the PP populations were all over 85%. Both regimens were well tolerated, with no differences in adverse events between the groups. Amoxycillin-clavulanate 2000/125 mg, twice daily, is well tolerated and at least as effective clinically as amoxycillin-clavulanate 1000/125 mg, three times daily, in patients with CAP and may also be appropriate for the treatment of infections due to S. pneumoniae strains with high-level penicillin resistance.
Bekker, Pirow; Dairaghi, Daniel; Seitz, Lisa; Leleti, Manmohan; Wang, Yu; Ertl, Linda; Baumgart, Trageen; Shugarts, Sarah; Lohr, Lisa; Dang, Ton; Miao, Shichang; Zeng, Yibin; Fan, Pingchen; Zhang, Penglie; Johnson, Daniel; Powers, Jay; Jaen, Juan; Charo, Israel; Schall, Thomas J
2016-01-01
The complement 5a receptor has been an attractive therapeutic target for many autoimmune and inflammatory disorders. However, development of a selective and potent C5aR antagonist has been challenging. Here we describe the characterization of CCX168 (avacopan), an orally administered selective and potent C5aR inhibitor. CCX168 blocked the C5a binding, C5a-mediated migration, calcium mobilization, and CD11b upregulation in U937 cells as well as in freshly isolated human neutrophils. CCX168 retains high potency when present in human blood. A transgenic human C5aR knock-in mouse model allowed comparison of the in vitro and in vivo efficacy of the molecule. CCX168 effectively blocked migration in in vitro and ex vivo chemotaxis assays, and it blocked the C5a-mediated neutrophil vascular endothelial margination. CCX168 was effective in migration and neutrophil margination assays in cynomolgus monkeys. This thorough in vitro and preclinical characterization enabled progression of CCX168 into the clinic and testing of its safety, tolerability, pharmacokinetic, and pharmacodynamic profiles in a Phase 1 clinical trial in 48 healthy volunteers. CCX168 was shown to be well tolerated across a broad dose range (1 to 100 mg) and it showed dose-dependent pharmacokinetics. An oral dose of 30 mg CCX168 given twice daily blocked the C5a-induced upregulation of CD11b in circulating neutrophils by 94% or greater throughout the entire day, demonstrating essentially complete target coverage. This dose regimen is being tested in clinical trials in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis. Trial Registration ISRCTN registry with trial ID ISRCTN13564773.
Bekker, Pirow; Dairaghi, Daniel; Seitz, Lisa; Leleti, Manmohan; Wang, Yu; Ertl, Linda; Baumgart, Trageen; Shugarts, Sarah; Lohr, Lisa; Dang, Ton; Miao, Shichang; Zeng, Yibin; Fan, Pingchen; Zhang, Penglie; Johnson, Daniel; Powers, Jay; Jaen, Juan; Charo, Israel; Schall, Thomas J.
2016-01-01
The complement 5a receptor has been an attractive therapeutic target for many autoimmune and inflammatory disorders. However, development of a selective and potent C5aR antagonist has been challenging. Here we describe the characterization of CCX168 (avacopan), an orally administered selective and potent C5aR inhibitor. CCX168 blocked the C5a binding, C5a-mediated migration, calcium mobilization, and CD11b upregulation in U937 cells as well as in freshly isolated human neutrophils. CCX168 retains high potency when present in human blood. A transgenic human C5aR knock-in mouse model allowed comparison of the in vitro and in vivo efficacy of the molecule. CCX168 effectively blocked migration in in vitro and ex vivo chemotaxis assays, and it blocked the C5a-mediated neutrophil vascular endothelial margination. CCX168 was effective in migration and neutrophil margination assays in cynomolgus monkeys. This thorough in vitro and preclinical characterization enabled progression of CCX168 into the clinic and testing of its safety, tolerability, pharmacokinetic, and pharmacodynamic profiles in a Phase 1 clinical trial in 48 healthy volunteers. CCX168 was shown to be well tolerated across a broad dose range (1 to 100 mg) and it showed dose-dependent pharmacokinetics. An oral dose of 30 mg CCX168 given twice daily blocked the C5a-induced upregulation of CD11b in circulating neutrophils by 94% or greater throughout the entire day, demonstrating essentially complete target coverage. This dose regimen is being tested in clinical trials in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis. Trial Registration ISRCTN registry with trial ID ISRCTN13564773. PMID:27768695
Kishan, Amar U; Cao, Minsong; Mikaeilian, Argin G; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Kamrava, Mitchell
2015-01-01
The purpose of this study was to investigate the dosimetric differences of delivering preoperative intensity modulated radiation therapy (IMRT) to patients with soft tissue sarcomas of the extremity (ESTS) with a teletherapy system equipped with 3 rotating (60)Co sources and a built-in magnetic resonance imaging and with standard linear accelerator (LINAC)-based IMRT. The primary study population consisted of 9 patients treated with preoperative radiation for ESTS between 2008 and 2014 with LINAC-based static field IMRT. LINAC plans were designed to deliver 50 Gy in 25 fractions to 95% of the planning target volume (PTV). Tri-(60)Co system IMRT plans were designed with ViewRay system software. Tri-(60)Co-based IMRT plans achieved equivalent target coverage and dosimetry for organs at risk (long bone, skin, and skin corridor) compared with LINAC-based IMRT plans. The maximum and minimum PTV doses, heterogeneity indices, and ratio of the dose to 50% of the volume were equivalent for both planning systems. One LINAC plan violated the maximum bone dose constraint, whereas none of the tri-(60)Co plans did. Using a tri-(60)Co system, we were able to achieve equivalent dosimetry to the PTV and organs at risk for patients with ESTS compared with LINAC-based IMRT plans. The tri-(60)Co system may be advantageous over current treatment platforms by allowing PTV reduction and by elimination of the additional radiation dose associated with daily image guidance, but this needs to be evaluated prospectively. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eich, Hans Theodor; Engenhart-Cabillic, Rita; Hansemann, Katja
2008-08-01
Purpose: The German Hodgkin Study Group (GHSG) set up a radiotherapy (RT) reference center within the Department of Radiation Oncology at University of Cologne to undertake quality assurance of the group's clinical studies. In the HD10 trial (early-favorable stages) and HD11 trial (early-unfavorable stages) all patients received involved field (IF)-RT (30 Gy vs. 20 Gy) within a combined-modality approach. For these patients a central prospective review of all diagnostic imaging was performed by expert radiation oncologists to control disease extension and to define IF treatment volume. Methods and Materials: On the basis of simulation films, verification films, and radiotherapy casemore » report form (CRF) an expert panel evaluated retrospectively the adequacy of irradiated IF treatment portals according to the RT prescription, applied radiation doses, treatment time, and technical parameters. Results: Between 1999 and 2006 a total of 825 of 1370 randomized patients of the HD10 trial (60%) and 954 of 1422 patients of the HD11 trial (67%) were evaluated by the panel. Radiotherapy was rated as suboptimal in 47% of all reviewed cases. Although the participating RT centers received a precise RT prescription, most difficulties occurred in the adequate coverage of the IF (40%), followed by technical faults (12%). Deviations from the prescribed single daily dose (1.8-2 Gy), weekly dose, and total reference dose were rare (1%). Conclusions: As a consequence of these findings, radiation oncologists were trained on the definition of IF-RT at GHSG meetings and at the annual meetings of the German Society for Therapeutic Radiation Oncology. Possible correlations between RT quality and relapse rate will be investigated.« less
Lagerwaard, Frank; Bohoudi, Omar; Tetar, Shyama; Admiraal, Marjan A; Rosario, Tezontl S; Bruynzeel, Anna
2018-04-05
Magnetic resonance-guided radiation therapy (MRgRT) not only allows for superior soft-tissue setup and online MR-guidance during delivery but also for inter-fractional plan re-optimization or adaptation. This plan adaptation involves repeat MR imaging, organs at risk (OARs) re-contouring, plan prediction (i.e., recalculating the baseline plan on the anatomy of that moment), plan re-optimization, and plan quality assurance. In contrast, intrafractional plan adaptation cannot be simply performed by pausing delivery at any given moment, adjusting contours, and re-optimization because of the complex and composite nature of deformable dose accumulation. To overcome this limitation, we applied a practical workaround by partitioning treatment fractions, each with half the original fraction dose. In between successive deliveries, the patient remained in the treatment position and all steps of the initial plan adaptation were repeated. Thus, this second re-optimization served as an intrafractional plan adaptation at 50% of the total delivery. The practical feasibility of this partitioning approach was evaluated in a patient treated with MRgRT for locally advanced pancreatic cancer (LAPC). MRgRT was delivered in 40Gy in 10 fractions, with two fractions scheduled successively on each treatment day. The contoured gross tumor volume (GTV) was expanded by 3 mm, excluding parts of the OARs within this expansion to derive the planning target volume for daily re-optimization (PTV OPT ). The baseline GTVV 95% achieved in this patient was 80.0% to adhere to the high-dose constraints for the duodenum, stomach, and bowel (V 33 Gy <1 cc and V 36 Gy <0.1 cc). Treatment was performed on the MRIdian (ViewRay Inc, Mountain View, USA) using video-assisted breath-hold in shallow inspiration. The dual plan adaptation resulted, for each partitioned fraction, in the generation of Plan PREDICTED1 , Plan RE-OPTIMIZED1 (inter-fractional adaptation), Plan PREDICTED2 , and Plan RE-OPTIMIZED2 (intrafractional adaptation). An offline analysis was performed to evaluate the benefit of inter-fractional versus intrafractional plan adaptation with respect to GTV coverage and high-dose OARs sparing for all five partitioned fractions. Interfractional changes in adjacent OARs were substantially larger than intrafractional changes. Mean GTV V 95% was 76.8 ± 1.8% (Plan PREDICTED1 ), 83.4 ± 5.7% (Plan RE-OPTIMIZED1 ), 82.5 ± 4.3% (Plan PREDICTED2 ),and 84.4 ± 4.4% (Plan RE-OPTIMIZED2 ). Both plan re-optimizations appeared important for correcting the inappropriately high duodenal V 33 Gy values of 3.6 cc (Plan PREDICTED1 ) and 3.9 cc (Plan PREDICTED2 ) to 0.2 cc for both re-optimizations. To a smaller extent, this improvement was also observed for V 25 Gy values. For the stomach, bowel, and all other OARs, high and intermediate doses were well below preset constraints, even without re-optimization. The mean delivery time of each daily treatment was 90 minutes. This study presents the clinical application of combined inter-fractional and intrafractional plan adaptation during MRgRT for LAPC using fraction partitioning with successive re-optimization. Whereas, in this study, interfractional plan adaptation appeared to benefit both GTV coverage and OARs sparing, intrafractional adaptation was particularly useful for high-dose OARs sparing. Although all necessary steps lead to a prolonged treatment duration, this may be applied in selected cases where high doses to adjacent OARs are regarded as critical.
Bohoudi, Omar; Tetar, Shyama; Admiraal, Marjan A; Rosario, Tezontl S; Bruynzeel, Anna
2018-01-01
Magnetic resonance-guided radiation therapy (MRgRT) not only allows for superior soft-tissue setup and online MR-guidance during delivery but also for inter-fractional plan re-optimization or adaptation. This plan adaptation involves repeat MR imaging, organs at risk (OARs) re-contouring, plan prediction (i.e., recalculating the baseline plan on the anatomy of that moment), plan re-optimization, and plan quality assurance. In contrast, intrafractional plan adaptation cannot be simply performed by pausing delivery at any given moment, adjusting contours, and re-optimization because of the complex and composite nature of deformable dose accumulation. To overcome this limitation, we applied a practical workaround by partitioning treatment fractions, each with half the original fraction dose. In between successive deliveries, the patient remained in the treatment position and all steps of the initial plan adaptation were repeated. Thus, this second re-optimization served as an intrafractional plan adaptation at 50% of the total delivery. The practical feasibility of this partitioning approach was evaluated in a patient treated with MRgRT for locally advanced pancreatic cancer (LAPC). MRgRT was delivered in 40Gy in 10 fractions, with two fractions scheduled successively on each treatment day. The contoured gross tumor volume (GTV) was expanded by 3 mm, excluding parts of the OARs within this expansion to derive the planning target volume for daily re-optimization (PTVOPT). The baseline GTVV95% achieved in this patient was 80.0% to adhere to the high-dose constraints for the duodenum, stomach, and bowel (V33 Gy <1 cc and V36 Gy <0.1 cc). Treatment was performed on the MRIdian (ViewRay Inc, Mountain View, USA) using video-assisted breath-hold in shallow inspiration. The dual plan adaptation resulted, for each partitioned fraction, in the generation of PlanPREDICTED1, PlanRE-OPTIMIZED1 (inter-fractional adaptation), PlanPREDICTED2, and PlanRE-OPTIMIZED2 (intrafractional adaptation). An offline analysis was performed to evaluate the benefit of inter-fractional versus intrafractional plan adaptation with respect to GTV coverage and high-dose OARs sparing for all five partitioned fractions. Interfractional changes in adjacent OARs were substantially larger than intrafractional changes. Mean GTV V95% was 76.8 ± 1.8% (PlanPREDICTED1), 83.4 ± 5.7% (PlanRE-OPTIMIZED1), 82.5 ± 4.3% (PlanPREDICTED2),and 84.4 ± 4.4% (PlanRE-OPTIMIZED2). Both plan re-optimizations appeared important for correcting the inappropriately high duodenal V33 Gy values of 3.6 cc (PlanPREDICTED1) and 3.9 cc (PlanPREDICTED2) to 0.2 cc for both re-optimizations. To a smaller extent, this improvement was also observed for V25 Gy values. For the stomach, bowel, and all other OARs, high and intermediate doses were well below preset constraints, even without re-optimization. The mean delivery time of each daily treatment was 90 minutes. This study presents the clinical application of combined inter-fractional and intrafractional plan adaptation during MRgRT for LAPC using fraction partitioning with successive re-optimization. Whereas, in this study, interfractional plan adaptation appeared to benefit both GTV coverage and OARs sparing, intrafractional adaptation was particularly useful for high-dose OARs sparing. Although all necessary steps lead to a prolonged treatment duration, this may be applied in selected cases where high doses to adjacent OARs are regarded as critical. PMID:29876156
Lu, Ming; Chu, Yao-Zhu; Yu, Wen-Zhou; Scherpbier, Robert; Zhou, Yu-Qing; Zhu, Xu; Su, Qi-Ru; Duan, Meng-Juan; Zhang, Xuan; Cui, Fu-Qiang; Wang, Hua-Qing; Zhou, Yi-Biao; Jiang, Qing-Wu
2017-04-24
Communication for Development (C4D) is a strategy promoted by the United Nations Children's Fund to foster positive and measurable changes at the individual, family, community, social, and policy levels of society. In western China, C4D activities have previously been conducted as part of province-level immunization programs. In this study, we evaluated the association of C4D with changes in parental knowledge of immunization services, measles disease, and measles vaccine, and changes in their children's measles vaccine coverage. From April 2013 to April 2014, C4D activities were implemented as part of provincial immunization programs in the Inner Mongolia, Guangxi, Chongqing, Guizhou, Tibet, Shaanxi, Gansu, Ningxia, and Qinghai provinces. We used a before-and-after study design and employed face-to-face interviews to assess changes in parental knowledge and vaccination coverage. We surveyed 2 107 households at baseline and 2 070 households after 1 year of C4D activities. Following C4D, 95% of caregivers were aware of the vaccination record check requirement for entry into kindergarten and primary school; 80% of caregivers were aware that migrant children were eligible for free vaccination; more than 70% of caregivers knew that measles is a respiratory infectious disease; and 90% of caregivers knew the symptoms of measles. Caregivers' willingness to take their children to the clinic for vaccination increased from 51.3% at baseline to 67.4% in the post-C4D survey. Coverage of one-dose measles-containing vaccine (MCV) increased from 83.8% at baseline to 90.1% after C4D. One-dose MCV coverage was greater than 95% in the Guangxi, Shaanxi, and Gansu provinces. Two-dose MCV coverage increased from 68.5 to 77.6%. House-to-house communication was the most popular C4D activity among caregivers (91.6% favoring), followed by posters and educational talks (64.8 and 49.9% favoring). C4D is associated with increased caregiver knowledge about measles, increased willingness to seek immunization services for their children, and increased measles vaccination coverage. Tailored communication strategies based on insights gained from these analyses may be able to increase vaccination coverage in hard-to-reach areas. C4D should be considered for larger scale implementation in China.
NASA Astrophysics Data System (ADS)
Jeong, Hyeran; Park, Donguk
2017-09-01
The aims of this study were to quantify the contributions of activities or microenvironments (MEs) to daily total exposure to and potential dose of black carbon (BC). Daily BC exposures (24-h) were monitored using a micro-aethalometer micoAeth AE51 with forty school-aged children living in an urban area in Korea from August 2015 to January 2016. The children's time-activity patterns and the MEs they visited were investigated by means of a time-activity diary (TAD) and follow-up interviews with the children and their parents. Potential inhaled dose was estimated by multiplying the airborne BC concentrations (μg/m3) we monitored for the time the children spent in a particular ME by the inhalation rate (IR, m3/h) for the time-activity performed. The contribution of activities and MEs to overall daily exposure to and potential dose of BC was quantified. Overall mean daily potential dose was equal to 24.1 ± 10.6 μg/day (range: 6.6-46.3 μg/day). The largest contribution to BC exposure and potential dose (51.9% and 41.7% respectively) occurred in the home thanks to the large amount of time spent there. Transportation was where children received the most intense exposure to (14.8%) and potential dose (20.2%) of BC, while it accounted for 7.6% of daily time. School on weekdays during the semester was responsible for 20.3% of exposure and 22.5% of potential dose. Contribution to BC exposure and potential dose was altered by several time-activity parameters, such as type of day (weekdays vs. weekends; school days vs. holidays), season, and gender. Traveling by motor vehicle and subway showed more elevated exposure or potential dose intensity on weekdays or school days, probably influenced by the increased surrounding traffic volumes on these days compared to on weekends or holidays. This study may be used to prioritize targets for minimizing children's exposure to BC and to indicate outcomes of BC control strategies.
Dose coverage calculation using a statistical shape model—applied to cervical cancer radiotherapy
NASA Astrophysics Data System (ADS)
Tilly, David; van de Schoot, Agustinus J. A. J.; Grusell, Erik; Bel, Arjan; Ahnesjö, Anders
2017-05-01
A comprehensive methodology for treatment simulation and evaluation of dose coverage probabilities is presented where a population based statistical shape model (SSM) provide samples of fraction specific patient geometry deformations. The learning data consists of vector fields from deformable image registration of repeated imaging giving intra-patient deformations which are mapped to an average patient serving as a common frame of reference. The SSM is created by extracting the most dominating eigenmodes through principal component analysis of the deformations from all patients. The sampling of a deformation is thus reduced to sampling weights for enough of the most dominating eigenmodes that describe the deformations. For the cervical cancer patient datasets in this work, we found seven eigenmodes to be sufficient to capture 90% of the variance in the deformations of the, and only three eigenmodes for stability in the simulated dose coverage probabilities. The normality assumption of the eigenmode weights was tested and found relevant for the 20 most dominating eigenmodes except for the first. Individualization of the SSM is demonstrated to be improved using two deformation samples from a new patient. The probabilistic evaluation provided additional information about the trade-offs compared to the conventional single dataset treatment planning.
Oral 5-aminosalicylic acid for induction of remission in ulcerative colitis.
Feagan, Brian G; Macdonald, John K
2012-10-17
Oral 5-aminosalicylic acid (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs in doses of at least 2 g/day, were more effective than placebo but no more effective than SASP for inducing remission in ulcerative colitis. This updated review includes more recent studies and evaluates the efficacy and safety of 5-ASA preparations used for the treatment of mild to moderately active ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for induction of remission in active ulcerative colitis. A secondary objective of this systematic review was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A computer-assisted literature search for relevant studies (inception to January 20, 2012) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled clinical trials of parallel design, with a minimum treatment duration of four weeks. Studies of oral 5-ASA therapy for treatment of patients with active ulcerative colitis compared with placebo, SASP or other formulations of 5-ASA were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA (two or three times daily) and 5-ASA dose ranging studies were also considered for inclusion. The outcomes of interest were the failure to induce global/clinical remission, global/clinical improvement, endoscopic remission, endoscopic improvement, adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. SASP-controlled trials were subgrouped by 5-ASA/SASP mass ratios. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol, Claversal, Salofalk and Pentasa). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the relative risk (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention to treat basis. Forty-eight studies (7776 patients) were included. The majority of included studies were rated as low risk of bias. 5-ASA was significantly superior to placebo with regard to all measured outcome variables. Seventy-two per cent of 5-ASA patients failed to enter clinical remission compared to 85% of placebo patients (RR 0.86, 95% CI 0.81 to 0.91). A dose-response trend for 5-ASA was also observed. No statistically significant differences in efficacy were found between 5-ASA and SASP. Fifty-four per cent of 5-ASA patients failed to enter remission compared to 58% of SASP patients (RR 0.90, 95% CI 0.77 to 1.04). No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Forty-two per cent of once daily patients failed to enter clinical remission compared to 44% of conventionally dosed patients (RR 0.95, 95% CI 0.82 to 1.10). Eight per cent of patients dosed once daily failed to adhere to their medication regimen compared to 6% of conventionally dosed patients (RR 1.36, 95% CI 0.64 to 2.86). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Forty-eight per cent of patients in the 5-ASA group failed to enter remission compared to 50% of patients in the 5-ASA comparator group (RR 0.94, 95% CI 0.86 to 1.03). A pooled analysis of the ASCEND (I, II and III, n = 1459 patients) studies found no statistically significant difference in clinical improvement between Asacol 4.8 g/day and 2.4 g/day used for the treatment of moderately active ulcerative colitis. Thirty-seven per cent of patients in the 4.8 g/day group failed to improve clinically compared to 41% of patients in the 2.4 g/day group (RR 0.89; 95% CI 0.78 to 1.01). Subgroup analysis indicated that patients with moderate disease may benefit from the higher dose of 4.8 g/day. One study compared (n = 123 patients) Pentasa 4 g/day to 2.25 g/day in patients with moderate disease. Twenty-five per cent of patients in the 4 g/day group failed to improve clinically compared to 57% of patients in the 2.25 g/day group (RR 0.44; 95% CI 0.27 to 0.71). A pooled analysis of two studies comparing MMX mesalamine 4.8 g/day to 2.4 g/day found no statistically significant difference in efficacy (RR 1.03, 95% CI 0.82 to 1.29). 5-ASA was generally safe and common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache and worsening ulcerative colitis. There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulation and 5-ASA dose ranging (high dose versus low dose) studies. SASP was not as well tolerated as 5-ASA. Twenty-nine percent of SASP patients experienced an adverse event compared to 15% of 5-ASA patients (RR 0.48, 95% CI 0.37 to 0.63). 5-ASA was superior to placebo and no more effective than SASP. Considering their relative costs, a clinical advantage to using oral 5-ASA in place of SASP appears unlikely. 5-ASA dosed once daily appears to be as efficacious and safe as conventionally dosed 5-ASA. Adherence does not appear to be enhanced by once daily dosing in the clinical trial setting. It is unknown if once daily dosing of 5-ASA improves adherence in a community-based setting. There do not appear to be any differences in efficacy or safety among the various 5-ASA formulations. A daily dosage of 2.4 g appears to be a safe and effective induction therapy for patients with mild to moderately active ulcerative colitis. Patients with moderate disease may benefit from an initial dose of 4.8 g/day.
Oral 5-aminosalicylic acid for induction of remission in ulcerative colitis.
Wang, Yongjun; Parker, Claire E; Bhanji, Tania; Feagan, Brian G; MacDonald, John K
2016-04-21
Oral 5-aminosalicylic acid (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs in doses of at least 2 g/day, were more effective than placebo but no more effective than SASP for inducing remission in ulcerative colitis. This updated review includes more recent studies and evaluates the efficacy and safety of 5-ASA preparations used for the treatment of mild to moderately active ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for induction of remission in active ulcerative colitis. A secondary objective of this systematic review was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A computer-assisted literature search for relevant studies (inception to July 9, 2015) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled clinical trials of parallel design, with a minimum treatment duration of four weeks. Studies of oral 5-ASA therapy for treatment of patients with active ulcerative colitis compared with placebo, SASP or other formulations of 5-ASA were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA (two or three times daily) and 5-ASA dose ranging studies were also considered for inclusion. The outcomes of interest were the failure to induce global/clinical remission, global/clinical improvement, endoscopic remission, endoscopic improvement, adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. SASP-controlled trials were subgrouped by 5-ASA/SASP mass ratios. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol, Claversal, Salofalk and Pentasa). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the relative risk (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention-to-treat basis. Fifty-three studies (8548 patients) were included. The majority of included studies were rated as low risk of bias. 5-ASA was significantly superior to placebo with regard to all measured outcome variables. Seventy-one per cent of 5-ASA patients failed to enter clinical remission compared to 83% of placebo patients (RR 0.86, 95% CI 0.82 to 0.89). A dose-response trend for 5-ASA was also observed. No statistically significant differences in efficacy were found between 5-ASA and SASP. Fifty-four per cent of 5-ASA patients failed to enter remission compared to 58% of SASP patients (RR 0.90, 95% CI 0.77 to 1.04). No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Forty-five per cent of once daily patients failed to enter clinical remission compared to 48% of conventionally dosed patients (RR 0.94, 95% CI 0.83 to 1.07). Eight per cent of patients dosed once daily failed to adhere to their medication regimen compared to 6% of conventionally dosed patients (RR 1.36, 95% CI 0.64 to 2.86). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Fifty per cent of patients in the 5-ASA group failed to enter remission compared to 52% of patients in the 5-ASA comparator group (RR 0.94, 95% CI 0.86 to 1.02). A pooled analysis of 3 studies (n = 1459 patients) studies found no statistically significant difference in clinical improvement between Asacol 4.8 g/day and 2.4 g/day used for the treatment of moderately active ulcerative colitis. Thirty-seven per cent of patients in the 4.8 g/day group failed to improve clinically compared to 41% of patients in the 2.4 g/day group (RR 0.89; 95% CI 0.78 to 1.01). Subgroup analysis indicated that patients with moderate disease may benefit from the higher dose of 4.8 g/day. One study compared (n = 123 patients) Pentasa 4 g/day to 2.25 g/day in patients with moderate disease. Twenty-five per cent of patients in the 4 g/day group failed to improve clinically compared to 57% of patients in the 2.25 g/day group (RR 0.44; 95% CI 0.27 to 0.71). A pooled analysis of two studies comparing MMX mesalamine 4.8 g/day to 2.4 g/day found no statistically significant difference in efficacy (RR 1.03, 95% CI 0.82 to 1.29). There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulation and 5-ASA dose ranging (high dose versus low dose) studies. Common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache and worsening ulcerative colitis. SASP was not as well tolerated as 5-ASA. Twenty-nine percent of SASP patients experienced an adverse event compared to 15% of 5-ASA patients (RR 0.48, 95% CI 0.37 to 0.63). 5-ASA was superior to placebo and no more effective than SASP. Considering their relative costs, a clinical advantage to using oral 5-ASA in place of SASP appears unlikely. 5-ASA dosed once daily appears to be as efficacious and safe as conventionally dosed 5-ASA. Adherence does not appear to be enhanced by once daily dosing in the clinical trial setting. It is unknown if once daily dosing of 5-ASA improves adherence in a community-based setting. There do not appear to be any differences in efficacy or safety among the various 5-ASA formulations. A daily dosage of 2.4 g appears to be a safe and effective induction therapy for patients with mild to moderately active ulcerative colitis. Patients with moderate disease may benefit from an initial dose of 4.8 g/day.
Cost-effectiveness of allopurinol and febuxostat for the management of gout.
Jutkowitz, Eric; Choi, Hyon K; Pizzi, Laura T; Kuntz, Karen M
2014-11-04
Gout is the most common inflammatory arthritis in the United States. To evaluate the cost-effectiveness of urate-lowering treatment strategies for the management of gout. Markov model. Published literature and expert opinion. Patients for whom allopurinol or febuxostat is a suitable initial urate-lowering treatment. Lifetime. Health care payer. 5 urate-lowering treatment strategies were evaluated: no treatment; allopurinol- or febuxostat-only therapy; allopurinol-febuxostat sequential therapy; and febuxostat-allopurinol sequential therapy. Two dosing scenarios were investigated: fixed dose (80 mg of febuxostat daily, 0.80 success rate; 300 mg of allopurinol daily, 0.39 success rate) and dose escalation (≤120 mg of febuxostat daily, 0.82 success rate; ≤800 mg of allopurinol daily, 0.78 success rate). Discounted costs, discounted quality-adjusted life-years, and incremental cost-effectiveness ratios. In both dosing scenarios, allopurinol-only therapy was cost-saving. Dose-escalation allopurinol-febuxostat sequential therapy was more costly but more effective than dose-escalation allopurinol therapy, with an incremental cost-effectiveness ratio of $39 400 per quality-adjusted life-year. The relative rankings of treatments did not change. Our results were relatively sensitive to several potential variations of model assumptions; however, the cost-effectiveness ratios of dose escalation with allopurinol-febuxostat sequential therapy remained lower than the willingness-to-pay threshold of $109 000 per quality-adjusted life-year. Long-term outcome data for patients with gout, including medication adherence, are limited. Allopurinol single therapy is cost-saving compared with no treatment. Dose-escalation allopurinol-febuxostat sequential therapy is cost-effective compared with accepted willingness-to-pay thresholds. Agency for Healthcare Research and Quality.
Zelinska, Nataliya; Iotova, Violeta; Skorodok, Julia; Malievsky, Oleg; Peterkova, Valentina; Samsonova, Lubov; Rosenfeld, Ron G; Zadik, Zvi; Jaron-Mendelson, Michal; Koren, Ronit; Amitzi, Leanne; Raduk, Dmitri; Hershkovitz, Oren; Hart, Gili
2017-05-01
Daily injections are required for growth hormone (GH) replacement therapy, which may cause low compliance as a result of inconvenience and distress in patients. C-terminal peptide-modified human GH (MOD-4023) is developed for once-a-week dosing regimen in GH-deficient (GHD) adults and children. The present trial was a safety and dose-finding study for weekly MOD-4023 in GHD children. A multicenter, open-label, randomized, controlled phase 2 study in children with GHD, evaluating the safety, tolerability, pharmacokinetics/pharmacodynamics, and efficacy of three different weekly MOD-4023 doses, compared with daily recombinant human GH (r-hGH). The trial was conducted in 14 endocrinology centers in Europe. Fifty-three prepubertal children with GHD completed 12 months of treatment with either MOD-4023 (N = 42) or r-hGH (N = 11). C-terminal peptide-modified hGH (MOD-4023) was administered weekly at a dose of either 0.25, 0.48, or 0.66 mg/kg/wk and compared with daily hGH at a dose of 0.24 mg/kg/wk. MOD-4023 showed an estimated half-life approximately fivefold to 10-fold longer when compared with daily r-hGH. Insulin-like growth factor (IGF)-I and IGF-binding peptide 3 showed a dose-dependent increase during MOD-4023 treatment. IGF-I standard deviation score for MOD-4023 did not exceed +2. All MOD-4023 cohorts demonstrated adequate catch-up growth. The 0.66 mg/kg/wk dose demonstrated efficacy closest to daily r-hGH. No serious adverse events were observed during MOD-4023 treatment, and its tolerability was consistent with known properties of r-hGH. This study confirms the long-acting properties of MOD-4023 and shows a promising safety and tolerability profile. This provides support for initiation of a phase 3 study in GHD children using a single weekly injection of MOD-4023. Copyright © 2017 by the Endocrine Society
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corn, Paul G., E-mail: pcorn@mdanderson.org; Song, Danny Y.; Heath, Elisabeth
Purpose: To evaluate the feasibility of administering sunitinib in combination with androgen deprivation therapy and external-beam intensity modulated radiation therapy (XRT) in patients with localized high-risk prostate cancer. Methods and Materials: Seventeen men with localized adenocarcinoma of the prostate with cT2c-cT4 or Gleason 8-10 or prostate-specific antigen >20 ng/mL received initial androgen deprivation (leuprolide 22.5 mg every 12 weeks plus oral bicalutamide 50 mg daily) for 4-8 weeks before oral sunitinib 12.5, 25, or 37.5 mg daily for 4 weeks as lead-in, then concurrently with and 4 weeks after XRT (75.6 Gy in 42 fractions to prostate and seminal vesicles).more » A 3+3 sequential dose-escalation design was used to assess the frequency of dose-limiting toxicity (DLT) and establish a maximal tolerated dose of sunitinib. Results: Sunitinib at 12.5- and 25-mg dose levels was well tolerated. The first 4 patients enrolled at 37.5 mg experienced a DLT during lead-in, and a drug interaction between sunitinib and bicalutamide was suspected. The protocol was revised and concurrent bicalutamide omitted. Of the next 3 patients enrolled at 37.5 mg, 2 of 3 receiving concurrent therapy experienced DLTs during radiation: grade 3 diarrhea and grade 3 proctitis, respectively. Only 1 of 7 patients completed sunitinib at 37.5 mg daily, whereas 3 of 3 patients (25 mg as starting dose) and 3 of 4 patients (25 mg as reduced dose) completed therapy. Conclusions: The feasibility of combined vascular endothelial growth factor receptor (VEGFR)/platelet-derived growth factor receptor (PDGFR) inhibitor therapy, androgen deprivation, and radiation therapy for prostate cancer was established. Using a daily dosing regimen with lead-in, concurrent, and post-XRT therapy, the recommended phase 2 dose of sunitinib is 25 mg daily.« less
Gladding, Patrick; Webster, Mark; Zeng, Irene; Farrell, Helen; Stewart, Jim; Ruygrok, Peter; Ormiston, John; El-Jack, Seif; Armstrong, Guy; Kay, Patrick; Scott, Douglas; Gunes, Arzu; Dahl, Marja-Liisa
2008-12-01
This study evaluated the antiplatelet effect of a higher loading and maintenance dose regimen of clopidogrel and a possible drug interaction with verapamil. Clopidogrel loading doses above 600 mg have not resulted in more rapid or complete platelet inhibition. Higher maintenance dosages may be more effective than 75 mg/day. A double-blind, randomized, placebo-controlled trial was undertaken in 60 patients undergoing percutaneous coronary intervention. All patients received clopidogrel 600 mg at the start of the procedure. Using a 2 x 2 design, patients were allocated to clopidogrel 600 mg given 2 h later or matching placebo, and to verapamil 5 mg intra-arterial or placebo. Platelet function was measured using the VerifyNow P2Y12 analyzer (Accumetrics Ltd., San Diego, California) at 2, 4, and 7 h. Patients were further randomized to receive a clopidogrel 75 or 150 mg once daily, with platelet function assessed after 1 week. Two hours after the second dose of clopidogrel or placebo, platelet inhibition was 42 +/- 27% with clopidogrel, compared with 24 +/- 22% with placebo (p = 0.0006). By 5 h after the second dose, platelet inhibition was 49 +/- 30% with clopidogrel, compared with 29 +/- 22% with placebo (p = 0.01). No drug interaction was seen with verapamil. A clopidogrel maintenance dosage of 150 mg daily for 1 week resulted in greater platelet inhibition than 75 mg daily (50 +/- 28% vs. 29 +/- 19%, p = 0.01). In an unselected population undergoing percutaneous coronary intervention a clopidogrel 1,200-mg loading dose, given as two 600-mg doses 2 h apart, results in more rapid and complete platelet inhibition than a single 600-mg dose. A maintenance dosage of 150 mg daily produces greater platelet inhibition than 75 mg daily. (The PRINC trial; ACTRN12606000129583).
Automatic cloud coverage assessment of Formosat-2 image
NASA Astrophysics Data System (ADS)
Hsu, Kuo-Hsien
2011-11-01
Formosat-2 satellite equips with the high-spatial-resolution (2m ground sampling distance) remote sensing instrument. It has been being operated on the daily-revisiting mission orbit by National Space organization (NSPO) of Taiwan since May 21 2004. NSPO has also serving as one of the ground receiving stations for daily processing the received Formosat- 2 images. The current cloud coverage assessment of Formosat-2 image for NSPO Image Processing System generally consists of two major steps. Firstly, an un-supervised K-means method is used for automatically estimating the cloud statistic of Formosat-2 image. Secondly, manual estimation of cloud coverage from Formosat-2 image is processed by manual examination. Apparently, a more accurate Automatic Cloud Coverage Assessment (ACCA) method certainly increases the efficiency of processing step 2 with a good prediction of cloud statistic. In this paper, mainly based on the research results from Chang et al, Irish, and Gotoh, we propose a modified Formosat-2 ACCA method which considered pre-processing and post-processing analysis. For pre-processing analysis, cloud statistic is determined by using un-supervised K-means classification, Sobel's method, Otsu's method, non-cloudy pixels reexamination, and cross-band filter method. Box-Counting fractal method is considered as a post-processing tool to double check the results of pre-processing analysis for increasing the efficiency of manual examination.
Safety and efficacy of fixed-dose 10 mg daily isotretinoin treatment for acne vulgaris in Malaysia.
Yap, Felix Boon-Bin
2017-09-01
Low-dose isotretinoin is used to reduce side effects albeit higher relapse. This study aimed to determine the efficacy and safety of fixed-dose 10 mg daily isotretinoin for the treatment of acne. This prospective study was performed between 2011 and 2015. All 150 patients were given 10 mg daily isotretinoin until a cumulative dose of 90-110 mg/kg. The mean age was 26.6 years with 64.7% moderate acne, 29.3% severe, and 6% very severe. The mean cumulative dose was 98.8 ± 6.05 mg/kg. All 150 patients had total clearance with a mean time to clearance of 24.0 weeks. Patients with severe/very severe acne had higher cumulative dosage (102.1 vs. 97.0, P < 0.001) and longer duration to clearance (32.9 weeks vs. 19.1 weeks, P < 0.001). Mild relapse was seen in 4%. The mean time to relapse was 32.3 weeks. Lip dryness was the commonest side effects (100%). Mild transient elevation of liver enzymes was detected in 3.3% and a slight increase of serum lipid in 2.7% with no treatment discontinuation. Fixed-dose 10 mg daily treatment with isotretinoin until a cumulative dose of 90-110 mg/kg is safe with low relapse rate. © 2016 Wiley Periodicals, Inc.
Ruer-Mulard, Mireille; Aberer, Werner; Gunstone, Anthony; Kekki, Outi-Maria; López Estebaranz, Jose Luis; Vertruyen, André; Guettner, Achim; Hultsch, Thomas
2009-01-01
The aim of this study is to compare twice-daily and once-daily applications of pimecrolimus cream 1% for prevention of atopic dermatitis relapses in pediatric patients. This multicenter trial enrolled 300 outpatients aged 2 to 17 years, with mild-to-severe atopic dermatitis. The patients were initially treated with twice-daily topical pimecrolimus until complete clearance or for up to 6 weeks (open-label period). Those who achieved a decrease of at least 1 point in the Investigator's Global Assessment score were then randomized to double-blind treatment with pimecrolimus cream 1% either twice daily or once daily for up to 16 weeks. Study medication was discontinued during periods of disease remission (Investigator's Global Assessment = 0). The primary efficacy end point of the double-blind phase was disease relapse (worsening requiring topical corticosteroids or additional/alternative therapy and confirmed by Investigator's Global Assessment score > or = 3 and pruritus score > or = 2). Of the 300 patients enrolled in the study, 268 were randomized to treatment with pimecrolimus cream 1% either twice daily or once daily (n = 134 in each group). The relapse rate was lower in the twice-daily dose group (9.9%) than that in the once-daily dose group (14.7%), but analysis of the time to disease relapse, using a Cox proportional model to adjust for confounding variables, did not show a statistically significant difference between treatment arms (hazard ratio: 0.64; 95% CI: 0.31-1.30). Treatment of active atopic dermatitis lesions with pimecrolimus cream 1% twice daily, followed by the once-daily dosing regimen, was sufficient to prevent subsequent atopic dermatitis relapses over 16 weeks in pediatric patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mwidu, U; Devic, S; Shehadeh, M
Purpose: A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented. Methods: Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended bymore » the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR. Results: TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively. Conclusion: Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.« less
Organ dose conversion coefficients for tube current modulated CT protocols for an adult population
NASA Astrophysics Data System (ADS)
Fu, Wanyi; Tian, Xiaoyu; Sahbaee, Pooyan; Zhang, Yakun; Segars, William Paul; Samei, Ehsan
2016-03-01
In computed tomography (CT), patient-specific organ dose can be estimated using pre-calculated organ dose conversion coefficients (organ dose normalized by CTDIvol, h factor) database, taking into account patient size and scan coverage. The conversion coefficients have been previously estimated for routine body protocol classes, grouped by scan coverage, across an adult population for fixed tube current modulated CT. The coefficients, however, do not include the widely utilized tube current (mA) modulation scheme, which significantly impacts organ dose. This study aims to extend the h factors and the corresponding dose length product (DLP) to create effective dose conversion coefficients (k factor) database incorporating various tube current modulation strengths. Fifty-eight extended cardiac-torso (XCAT) phantoms were included in this study representing population anatomy variation in clinical practice. Four mA profiles, representing weak to strong mA dependency on body attenuation, were generated for each phantom and protocol class. A validated Monte Carlo program was used to simulate the organ dose. The organ dose and effective dose was further normalized by CTDIvol and DLP to derive the h factors and k factors, respectively. The h factors and k factors were summarized in an exponential regression model as a function of body size. Such a population-based mathematical model can provide a comprehensive organ dose estimation given body size and CTDIvol. The model was integrated into an iPhone app XCATdose version 2, enhancing the 1st version based upon fixed tube current modulation. With the organ dose calculator, physicists, physicians, and patients can conveniently estimate organ dose.
A method to estimate the effect of deformable image registration uncertainties on daily dose mapping
Murphy, Martin J.; Salguero, Francisco J.; Siebers, Jeffrey V.; Staub, David; Vaman, Constantin
2012-01-01
Purpose: To develop a statistical sampling procedure for spatially-correlated uncertainties in deformable image registration and then use it to demonstrate their effect on daily dose mapping. Methods: Sequential daily CT studies are acquired to map anatomical variations prior to fractionated external beam radiotherapy. The CTs are deformably registered to the planning CT to obtain displacement vector fields (DVFs). The DVFs are used to accumulate the dose delivered each day onto the planning CT. Each DVF has spatially-correlated uncertainties associated with it. Principal components analysis (PCA) is applied to measured DVF error maps to produce decorrelated principal component modes of the errors. The modes are sampled independently and reconstructed to produce synthetic registration error maps. The synthetic error maps are convolved with dose mapped via deformable registration to model the resulting uncertainty in the dose mapping. The results are compared to the dose mapping uncertainty that would result from uncorrelated DVF errors that vary randomly from voxel to voxel. Results: The error sampling method is shown to produce synthetic DVF error maps that are statistically indistinguishable from the observed error maps. Spatially-correlated DVF uncertainties modeled by our procedure produce patterns of dose mapping error that are different from that due to randomly distributed uncertainties. Conclusions: Deformable image registration uncertainties have complex spatial distributions. The authors have developed and tested a method to decorrelate the spatial uncertainties and make statistical samples of highly correlated error maps. The sample error maps can be used to investigate the effect of DVF uncertainties on daily dose mapping via deformable image registration. An initial demonstration of this methodology shows that dose mapping uncertainties can be sensitive to spatial patterns in the DVF uncertainties. PMID:22320766
Peng, Shiwen; Lyford-Pike, Sofia; Akpeng, Belinda; Wu, Annie; Hung, Chien-Fu; Hannaman, Drew; Saunders, John R.; Wu, T.-C.
2012-01-01
Although therapeutic HPV vaccines are able to elicit systemic HPV-specific immunity, clinical responses have not always correlated with levels of vaccine-induced CD8+ T cells in human clinical trials. This observed discrepancy may be attributable to an immunosuppressive tumor microenvironment in which the CD8+ T cells are recruited. Regulatory T cells (Tregs) are cells that can dampen cytotoxic CD8+ T-cell function. Cyclophosphamide (CTX) is a systemic chemotherapeutic agent, which can eradicate immune cells, including inhibitory Tregs. The optimal dose and schedule of CTX administration in combination with immunotherapy to eliminate the Treg population without adversely affecting vaccine-induced T-cell responses is unknown. Therefore, we investigated various dosing and administration schedules of CTX in combination with a therapeutic HPV vaccine in a preclinical tumor model. HPV tumor-bearing mice received either a single preconditioning dose or a daily dose of CTX in combination with the pNGVL4a-CRT/E7(detox) DNA vaccine. Both single and daily dosing of CTX in combination with vaccine had a synergistic anti-tumor effect as compared to monotherapy alone. The potent antitumor responses were attributed to the reduction in Treg frequency and increased infiltration of HPV16 E7-specific CD8+ T cells, which led to higher ratios of CD8+/Treg and CD8+/CD11b+Gr-1+ myeloid-derived suppressor cells (MDSCs). There was an observed trend toward decreased vaccine-induced CD8+ T-cell frequency with daily dosing of CTX. We recommend a single, preconditioning dose of CTX prior to vaccination due to its efficacy, ease of administration, and reduced cumulative adverse effect on vaccine-induced T cells. PMID:23011589
Kazierad, D J; Bergman, A; Tan, B; Erion, D M; Somayaji, V; Lee, D S; Rolph, T
2016-08-01
To assess the pharmacokinetics, pharmacodynamics, safety and tolerability of multiple ascending doses of the glucagon receptor antagonist PF-06291874 in patients with type 2 diabetes mellitus (T2DM). Patients were randomized to oral PF-06291874 or placebo on a background of either metformin (Part A, Cohorts 1-5: 5-150 mg once daily), or metformin and sulphonylurea (Part B, Cohorts 1-2: 15 or 30 mg once daily) for 14-28 days. A mixed-meal tolerance test (MMTT) was administered on days -1 (baseline), 14 and 28. Assessments were conducted with regard to pharmacokinetics, various pharmacodynamic variables, safety and tolerability. Circulating amino acid concentrations were also measured. PF-06291874 exposure was approximately dose-proportional with a half-life of ∼19.7-22.7 h. Day 14 fasting plasma glucose and mean daily glucose values were reduced from baseline in a dose-dependent manner, with placebo-corrected decreases of 34.3 and 42.4 mg/dl, respectively, at the 150 mg dose. After the MMTT, dose-dependent increases in glucagon and total glucagon-like peptide-1 (GLP-1) were observed, although no meaningful changes were noted in insulin, C-peptide or active GLP-1 levels. Small dose-dependent increases in LDL cholesterol were observed, along with reversible increases in serum aminotransferases that were largely within the laboratory reference range. An increase in circulating gluconeogenic amino acids was also observed on days 2 and 14. All dose levels of PF-06291874 were well tolerated. PF-06291874 was well tolerated, has a pharmacokinetic profile suitable for once-daily dosing, and results in reductions in glucose with minimal risk of hypoglycaemia. © 2016 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, Jeff, E-mail: jmeye3@utsouthwestern.ed; Bluett, Jaques; Amos, Richard
Purpose: Conventional proton therapy with passively scattered beams is used to treat a number of tumor sites, including prostate cancer. Spot scanning proton therapy is a treatment delivery means that improves conformal coverage of the clinical target volume (CTV). Placement of individual spots within a target is dependent on traversed tissue density. Errors in patient alignment perturb dose distributions. Moreover, there is a need for a rational planning approach that can mitigate the dosimetric effect of random alignment errors. We propose a treatment planning approach and then analyze the consequences of various simulated alignment errors on prostate treatments. Methods andmore » Materials: Ten control patients with localized prostate cancer underwent treatment planning for spot scanning proton therapy. After delineation of the clinical target volume, a scanning target volume (STV) was created to guide dose coverage. Errors in patient alignment in two axes (rotational and yaw) as well as translational errors in the anteroposterior direction were then simulated, and dose to the CTV and normal tissues were reanalyzed. Results: Coverage of the CTV remained high even in the setting of extreme rotational and yaw misalignments. Changes in the rectum and bladder V45 and V70 were similarly minimal, except in the case of translational errors, where, as a result of opposed lateral beam arrangements, much larger dosimetric perturbations were observed. Conclusions: The concept of the STV as applied to spot scanning radiation therapy and as presented in this report leads to robust coverage of the CTV even in the setting of extreme patient misalignments.« less
Internal Consistency of the NVAP Water Vapor Dataset
NASA Technical Reports Server (NTRS)
Suggs, Ronnie J.; Jedlovec, Gary J.; Arnold, James E. (Technical Monitor)
2001-01-01
The NVAP (NASA Water Vapor Project) dataset is a global dataset at 1 x 1 degree spatial resolution consisting of daily, pentad, and monthly atmospheric precipitable water (PW) products. The analysis blends measurements from the Television and Infrared Operational Satellite (TIROS) Operational Vertical Sounder (TOVS), the Special Sensor Microwave/Imager (SSM/I), and radiosonde observations into a daily collage of PW. The original dataset consisted of five years of data from 1988 to 1992. Recent updates have added three additional years (1993-1995) and incorporated procedural and algorithm changes from the original methodology. Since each of the PW sources (TOVS, SSM/I, and radiosonde) do not provide global coverage, each of these sources compliment one another by providing spatial coverage over regions and during times where the other is not available. For this type of spatial and temporal blending to be successful, each of the source components should have similar or compatible accuracies. If this is not the case, regional and time varying biases may be manifested in the NVAP dataset. This study examines the consistency of the NVAP source data by comparing daily collocated TOVS and SSM/I PW retrievals with collocated radiosonde PW observations. The daily PW intercomparisons are performed over the time period of the dataset and for various regions.
Crespo, M; Mir, M; Marin, M; Hurtado, S; Estadella, C; Gurí, X; Rap, O; Moral, R; Puig, J M; Lloveras, J
2009-01-01
Advagraf is a new modified-release once-daily formulation of tacrolimus with a similar efficacy and safety profile to twice-daily tacrolimus (Prograf) according to clinical trials. Few data are published about its use in clinical practice, outside of sponsored clinical trials. We compared efficacy and basic pharmacokinetics of once-daily and twice-daily tacrolimus in de novo renal transplantation. The Advagraf group included 26 de novo renal cases who had received initial immunosuppression with once-daily tacrolimus (0.2 mg/kg from day 1 posttransplantation) combined with mycophenolic acid, steroids, and anti-CD25 monoclonal antibodies (2 doses). We compared them with a Prograf group of 26 transplants performed immediately before, who received equivalent immunosuppression with twice-daily tacrolimus (0.2 mg/kg from day 1). We did not observe significant differences between groups in demographics, efficacy, and basic pharmacokinetics, namely, tacrolimus trough levels at 7, 15, 30, 60, or 90 days. We found that recipients on Advagraf needed significantly higher tacrolimus doses per kg up to 6 months post-transplantation than those on Prograf: 0.16 vs 0.11; 0.14 vs 0.08; and 0.12 vs 0.08 mg/kg at 1, 3, and 6 months. No patient suffered severe liver dysfunction. There were no differences between groups in the administration of drugs interacting with CYP3A4 or prokinetics, which could alter tacrolimus pharmacokinetics. Among de novo renal cases, the new once-daily formulation of tacrolimus offered a similar short-term efficacy profile as the twice-daily tacrolimus. But it was necessary to use up to a 50% higher dose of Advagraf than Prograf to achieve similar trough levels during the first 6 months.
Nielsen, Suzanne; Gisev, Natasa; Bruno, Raimondo; Hall, Wayne; Cohen, Milton; Larance, Briony; Campbell, Gabrielle; Shanahan, Marian; Blyth, Fiona; Lintzeris, Nicholas; Pearson, Sallie; Mattick, Richard; Degenhardt, Louisa
2017-05-01
To assess how well the defined daily dose (DDD) metric reflects opioid utilisation among chronic non-cancer pain patients. Descriptive, cross-sectional study, utilising a 7-day medication diary. Community-based treatment settings, Australia. A sample of 1101 people prescribed opioids for chronic non-cancer pain. Opioid dose data was collected via a self-completed 7-day medication diary capturing names, strengths and doses of each medication taken in the past week. Median daily dose was calculated for each opioid. Comparisons were made to the World Health Organization's (WHO) DDD metric. WHO DDDs ranged from 0.6 to 7.1 times the median opioid doses used by the sample. For transdermal fentanyl and oral hydromorphone, the median dose was comparable with the DDD. The DDD for methadone was 0.6 times lower than the median doses used by this sample of chronic pain patients. In contrast, the DDD for oxycodone and transdermal buprenorphine, the most commonly used strong opioids for chronic pain in Australia, was two to seven times higher than actual doses used. For many opioids, there are key differences between the actual doses used in clinical practice and the WHO's DDDs. The interpretation of opioid utilisation studies using population-level DDDs may be limited, and a recalibration of the DDD for many opioids or the reporting of opioid utilisation in oral morphine equivalent doses is recommended. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Improving birth dose coverage of hepatitis B vaccine.
Hipgrave, David B.; Maynard, James E.; Biggs, Beverley-Ann
2006-01-01
Administration of a birth dose of hepatitis B vaccine (HepB vaccine) to neonates is recommended to prevent mother-to-infant transmission and chronic infection with the hepatitis B virus (HBV). Although manufacturers recommend HepB vaccine distribution and storage at 2-8 degrees C, recognition of the heat stability of hepatitis B surface antigen stimulated research into its use after storage at, or exposure to, ambient or high temperatures. Storage of HepB vaccine at ambient temperatures would enable birth dosing for neonates delivered at home in remote areas or at health posts lacking refrigeration. This article reviews the current evidence on the thermostability of HepB vaccine when stored outside the cold chain (OCC). The reports reviewed show that the vaccines studied were safe and effective whether stored cold or OCC. Field and laboratory data also verifies the retained potency of the vaccine after exposure to heat. The attachment of a highly stable variety of a vaccine vial monitor (measuring cumulative exposure to heat) on many HepB vaccines strongly supports policies allowing their storage OCC, when this will benefit birth dose coverage. We recommend that this strategy be introduced to improve birth dose coverage, especially in rural and remote areas. Concurrent monitoring and evaluation should be undertaken to affirm the safe implementation of this strategy, and assess its cost, feasibility and effect on reducing HBV infection rates. Meanwhile, release of manufacturer data verifying the potency of currently available HepB vaccines after exposure to heat will increase confidence in the use of vaccine vial monitors as a managerial tool during storage of HepB vaccine OCC. PMID:16501717
Does closure of children's medical home impact their immunization coverage?
Kolasa, M S; Stevenson, J; Ossa, A; Lutz, J
2014-12-01
Little is known about the impact closing a health care facility has on immunization coverage of children utilizing that facility as a medical home. The authors assessed the impact of closing a Medicaid managed care facility in Philadelphia on immunization coverage of children, primarily low income children from racial/ethnic minority groups, utilizing that facility for routine immunizations. Observational longitudinal cohort case study. Eligible children were born 03/01/05-06/30/07, present in Philadelphia's immunization information system (IIS), and were active clients of the facility before it closed in September 2007. IIS-recorded immunization coverage at ages 5, 7, 13, 16 and 19 months through January 2009 was compared between clinic children age-eligible to receive specific vaccines before clinic closing (preclosure cohorts) and children not age-eligible to receive those vaccines prior to closing (postclosure cohorts). Of 630 eligible children, 99 (16%) had no additional IIS-recorded immunizations. Third dose DTaP vaccine coverage at age seven months among preclosure cohorts was 54.4% vs. 40.3% among postclosure cohorts [risk ratio 1.31 (1.15,1.49)]. Fourth dose DTaP coverage at 19 months was 65.9% vs. 57.7% [risk ratio 1.24 (1.08,1.42)]. MMR coverage at 16 months was 79.5% vs. 69.9% [risk ratio 1.47 (1.22, 1.76)]. Coverage for the 431331 vaccination series at 19 months was 63.8% vs. 53.8% [risk ratio 1.28 (1.12,1.88)]. Immunization coverage declined at key age milestones for active clients of a Medicaid managed care that closed as compared with preclosure cohorts of clients from the same facility. When a primary health care facility closes, efforts should be made to ensure that children who had received vaccinations at that facility quickly establish a new medical home. Published by Elsevier Ltd.
Kiely, Marilou; Boulianne, Nicole; Talbot, Denis; Ouakki, Manale; Guay, Maryse; Landry, Monique; Zafack, Joseline; Sauvageau, Chantal; De Serres, Gaston
2018-07-05
Between 2004 and 2016, in the province of Quebec (Canada), 4 new antigens were added in the early childhood vaccine schedule from birth to 18 months, increasing the number of injections or doses needed from 7 to 12. These additions may have decreased the proportion of children who had received all recommended vaccines. To assess the impact of the introduction of new vaccines to the childhood schedule on the 24-month vaccine coverage from 2006 to 2016 and identify factors associated with incomplete vaccination status by 24 months of age. We used the data from six cross-sectional vaccine coverage surveys conducted every two years which included a total of 3515 children aged 2 years old and randomly selected from the Quebec public health insurance database. Factors associated with an incomplete vaccine status by 24 months were identified with multivariable logistic regression. Despite the addition of 4 new vaccine antigens since 2004, the vaccine coverage remained high from 2006 (82.4%) through 2016 (88.3%) for vaccines present in the schedule since 2006. In 2016, vaccine coverage was 78.2% for all vaccines included in the schedule. The vaccine coverage of new vaccines increases rapidly within 2 years of their introduction. For both new and older vaccines, incomplete vaccine status by 24 months of age is associated with a delay of 30 days or more in receiving the vaccines scheduled at 2 and 12 months of age. Increasing to 12 the number of doses in the recommended schedule has slightly reduced the vaccine coverage by 24 months of age and the vaccine coverage of vaccines already in the schedule remained stable over the years. Future additions to the vaccine schedule may not be similarly accepted by the population and this will require continuing the monitoring of vaccine coverage. Copyright © 2018 Elsevier Ltd. All rights reserved.
Crude childhood vaccination coverage in West Africa: Trends and predictors of completeness.
Kazungu, Jacob S; Adetifa, Ifedayo M O
2017-02-15
Background : Africa has the lowest childhood vaccination coverage worldwide. If the full benefits of childhood vaccination programmes are to be enjoyed in sub-Saharan Africa, all countries need to improve on vaccine delivery to achieve and sustain high coverage. In this paper, we review trends in vaccination coverage, dropouts between vaccine doses and explored the country-specific predictors of complete vaccination in West Africa. Methods : We utilized datasets from the Demographic and Health Surveys Program, available for Benin, Burkina Faso, The Gambia, Ghana, Guinea, Cote d'Ivoire, Liberia, Mali, Niger, Nigeria, Senegal, Sierra Leone and Togo, to obtain coverage for Bacillus Calmette-Guerin, polio, measles, and diphtheria, pertussis and tetanus (DPT) vaccines in children aged 12 - 23 months. We also calculated the DPT1-to-DPT3 and DPT1-to-measles dropouts, and proportions of the fully immunised child (FIC). Factors predictive of FIC were explored using Chi-squared tests and multivariable logistic regression. Results : Overall, there was a trend of increasing vaccination coverage. The proportion of FIC varied significantly by country (range 24.1-81.4%, mean 49%). DPT1-to-DPT3 dropout was high (range 5.1% -33.9%, mean 16.3%). Similarly, DPT1-measles dropout exceeded 10% in all but four countries. Although no single risk factor was consistently associated with FIC across these countries, maternal education, delivery in a health facility, possessing a vaccine card and a recent post delivery visit to a health facility were the key predictors of complete vaccination. Conclusions : The low numbers of fully immunised children and high dropout between vaccine doses highlights weaknesses and the need to strengthen the healthcare and routine immunization delivery systems in this region. Country-specific correlates of complete vaccination should be explored further to identify interventions required to increase vaccination coverage. Despite the promise of an increasing trend in vaccination coverage in West African countries, more effort is required to attain and maintain global vaccination coverage targets.
A review of plan library approaches in adaptive radiotherapy of bladder cancer.
Collins, Shane D; Leech, Michelle M
2018-05-01
Large variations in the shape and size of the bladder volume are commonly observed in bladder cancer radiotherapy (RT). The clinical target volume (CTV) is therefore frequently inadequately treated and large isotropic margins are inappropriate in terms of dose to organs at risk (OAR); thereby making adaptive radiotherapy (ART) attractive for this tumour site. There are various methods of ART delivery, however, for bladder cancer, plan libraries are frequently used. A review of published studies on plan libraries for bladder cancer using four databases (Pubmed, Science Direct, Embase and Cochrane Library) was conducted. The endpoints selected were accuracy and feasibility of initiation of a plan library strategy into a RT department. Twenty-four articles were included in this review. The majority of studies reported improvement in accuracy with 10 studies showing an improvement in planning target volume (PTV) and CTV coverage with plan libraries, some by up to 24%. Seventeen studies showed a dose reduction to OARs, particularly the small bowel V45Gy, V40Gy, V30Gy and V10Gy, and the rectal V30Gy. However, the occurrence of no suitable plan was reported in six studies, with three studies showing no significant difference between adaptive and non-adaptive strategies in terms of target coverage. In addition, inter-observer variability in plan selection appears to remain problematic. The additional resources, education and technology required for the initiation of plan library selection for bladder cancer may hinder its routine clinical implementation, with eight studies illustrating increased treatment time required. While there is a growing body of evidence in support of plan libraries for bladder RT, many studies differed in their delivery approach. The advent of the clinical use of the MRI-linear accelerator will provide RT departments with the opportunity to consider daily online adaption for bladder cancer as an alternate to plan library approaches.
NASA Astrophysics Data System (ADS)
Jones, Bernard L.; Gan, Gregory; Kavanagh, Brian; Miften, Moyed
2013-11-01
An inflatable endorectal balloon (ERB) is often used during stereotactic body radiation therapy (SBRT) for treatment of prostate cancer in order to reduce both intrafraction motion of the target and risk of rectal toxicity. However, the ERB can exert significant force on the prostate, and this work assessed the impact of ERB position errors on deformation of the prostate and treatment dose metrics. Seventy-one cone-beam computed tomography (CBCT) image datasets of nine patients with clinical stage T1cN0M0 prostate cancer were studied. An ERB (Flexi-Cuff, EZ-EM, Westbury, NY) inflated with 60 cm3 of air was used during simulation and treatment, and daily kilovoltage (kV) CBCT imaging was performed to localize the prostate. The shape of the ERB in each CBCT was analyzed to determine errors in position, size, and shape. A deformable registration algorithm was used to track the dose received by (and deformation of) the prostate, and dosimetric values such as D95, PTV coverage, and Dice coefficient for the prostate were calculated. The average balloon position error was 0.5 cm in the inferior direction, with errors ranging from 2 cm inferiorly to 1 cm superiorly. The prostate was deformed primarily in the AP direction, and tilted primarily in the anterior-posterior/superior-inferior plane. A significant correlation was seen between errors in depth of ERB insertion (DOI) and mean voxel-wise deformation, prostate tilt, Dice coefficient, and planning-to-treatment prostate inter-surface distance (p < 0.001). Dosimetrically, DOI is negatively correlated with prostate D95 and PTV coverage (p < 0.001). For the model of ERB studied, error in ERB position can cause deformations in the prostate that negatively affect treatment, and this additional aspect of setup error should be considered when ERBs are used for prostate SBRT. Before treatment, the ERB position should be verified, and the ERB should be adjusted if the error is observed to exceed tolerable values.
Metronidazole stewardship initiative at Christchurch hospitals-achievable with immediate benefits.
Gardiner, Sharon J; Metcalf, Sarah Cl; Chin, Paul Kl; Doogue, Matthew P; Dalton, Simon C; Chambers, Stephen T
2018-04-13
To evaluate an antimicrobial stewardship (AMS) initiative to change hospital prescribing practice for metronidazole. In October 2015, the Canterbury District Health Board (CDHB) AMS committee changed advice for metronidazole to promote two times daily dosing for most indications, prioritisation of the oral route and avoidance of double anaerobic cover. Adoption of the initiative was facilitated via change in prescribing guidelines, education and ongoing pharmacy support. Usage and expenditure on metronidazole for adult inpatients were compared for the five years pre- and two years post-change. Other district health boards (DHBs) were surveyed to determine their dosing recommendation for metronidazole IV. Mean annual metronidazole IV use, as defined daily doses per 1,000 occupied bed days, decreased by 43% post-initiative. Use of non-IV (oral or rectal) formulations increased by 104%. Total savings associated with the initiative were approximately $33,400 in drug costs plus $78,200 per annum in IV giving sets and post-dose flushes. Twelve of 20 (60%) DHBs (including CDHB) endorse twice daily IV dosing. In addition to financial savings, reduction in IV doses has potential benefits, including avoidance of IV catheter-associated complications such as bloodstream infections. Approaches to metronidazole dosing vary across DHBs and could benefit from national coordination.
Cloessner, Emily A.; Stokley, Shannon; Yankey, David; Markowitz, Lauri E.
2016-01-01
Abstract The current recommendation for human papillomavirus (HPV) vaccination in the United States is for 3 doses to be administered over a 6 month period. In April 2014, the World Health Organization (WHO) recommended adoption of a 2-dose schedule, with doses spaced a minimum of 6 months apart, for teens who begin the series before age 15. We analyzed data from the 2013 National Immunization Survey-Teen to examine the timing of second and third dose receipt among US adolescents. All analyses were restricted to adolescents age 13–17 y who had adequate provider data. The Wilcoxon–Mann–Whitney test measured differences in time to receive vaccine doses among demographic and socioeconomic groups. Logistic regression identified socioeconomic characteristics associated with receiving the second dose of HPV vaccine at least 6 months after the first dose. The median time for teens to receive the second dose of HPV vaccine was 2.6 months after the first dose, and the median time to receive the third dose was 4.9 months after the second dose. Minority teens and teens living below the poverty level took significantly longer to receive doses. Among teens that initiated the HPV vaccine series before age 15 y, 28.6% received the second dose at least 6 months after the first dose. If these teens, who met the WHO criteria for up-to-date HPV vaccination, were classified as having completed the vaccination series, overall coverage in the US would increase 3.9 percentage points, with African American and Hispanic teens having the greatest increases in coverage. PMID:26587886
Cloessner, Emily A; Stokley, Shannon; Yankey, David; Markowitz, Lauri E
2016-06-02
The current recommendation for human papillomavirus (HPV) vaccination in the United States is for 3 doses to be administered over a 6 month period. In April 2014, the World Health Organization (WHO) recommended adoption of a 2-dose schedule, with doses spaced a minimum of 6 months apart, for teens who begin the series before age 15. We analyzed data from the 2013 National Immunization Survey-Teen to examine the timing of second and third dose receipt among US adolescents. All analyses were restricted to adolescents age 13-17 y who had adequate provider data. The Wilcoxon-Mann-Whitney test measured differences in time to receive vaccine doses among demographic and socioeconomic groups. Logistic regression identified socioeconomic characteristics associated with receiving the second dose of HPV vaccine at least 6 months after the first dose. The median time for teens to receive the second dose of HPV vaccine was 2.6 months after the first dose, and the median time to receive the third dose was 4.9 months after the second dose. Minority teens and teens living below the poverty level took significantly longer to receive doses. Among teens that initiated the HPV vaccine series before age 15 y, 28.6% received the second dose at least 6 months after the first dose. If these teens, who met the WHO criteria for up-to-date HPV vaccination, were classified as having completed the vaccination series, overall coverage in the US would increase 3.9 percentage points, with African American and Hispanic teens having the greatest increases in coverage.
Alignment focus of daily image guidance for concurrent treatment of prostate and pelvic lymph nodes.
Ferjani, Samah; Huang, Guangshun; Shang, Qingyang; Stephans, Kevin L; Zhong, Yahua; Qi, Peng; Tendulkar, Rahul D; Xia, Ping
2013-10-01
To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages. Copyright © 2013 Elsevier Inc. All rights reserved.
Non-daily pre-exposure prophylaxis for HIV prevention
Anderson, Peter L.; García-Lerma, J. Gerardo; Heneine, Walid
2015-01-01
Purpose of review To discuss non-daily pre-exposure prophylaxis (PrEP) modalities that may provide advantages compared with daily PrEP in cost and cumulative toxicity, but may have lower adherence forgiveness. Recent Findings Animal models have informed our understanding of early viral transmission events, which help guide event-driven PrEP dosing strategies. These models indicate early establishment of viral replication in rectal or cervicovaginal tissues, so event-driven PrEP should rapidly deliver high mucosal drug concentrations within hours of the potential exposure event. Macaque models have demonstrated the high biological efficacy for event-driven dosing of oral tenofovir disoproxil fumarate (TDF) and emtricitabine (FTC) against both vaginal and rectal virus transmission. In humans, the IPERGAY study demonstrated 86% efficacy for event-driven oral TDF/FTC dosing among men who have sex with men (MSM), while no similar efficacy data are available on women or heterosexual men. The HPTN 067 study showed that certain MSM populations adhere well to non-daily PrEP while other populations of women adhere more poorly to non-daily versus daily regimens. Pharmacokinetic studies following oral TDF/FTC dosing in humans, indicate that TFV-diphosphate (the active form of TFV) accumulates to higher concentrations in rectal versus cervicovaginal tissue but non-adherence in trials complicates the interpretation of differential mucosal drug concentrations. Summary Event-driven dosing for TFV-based PrEP has promise for HIV prevention in MSM. Future research of event-driven PrEP in women and heterosexual men should be guided by a better understanding of the importance of mucosal drug concentrations for PrEP efficacy and its sensitivity to adherence. PMID:26633641
Iron deficiency and iron excess damage mitochondria and mitochondrial DNA in rats
Walter, Patrick B.; Knutson, Mitchell D.; Paler-Martinez, Andres; Lee, Sonia; Xu, Yu; Viteri, Fernando E.; Ames, Bruce N.
2002-01-01
Approximately two billion people, mainly women and children, are iron deficient. Two studies examined the effects of iron deficiency and supplementation on rats. In study 1, mitochondrial functional parameters and mitochondrial DNA (mtDNA) damage were assayed in iron-deficient (≤5 μg/day) and iron-normal (800 μg/day) rats and in both groups after daily high-iron supplementation (8,000 μg/day) for 34 days. This dose is equivalent to the daily dose commonly given to iron-deficient humans. Iron-deficient rats had lower liver mitochondrial respiratory control ratios and increased levels of oxidants in polymorphonuclear-leukocytes, as assayed by dichlorofluorescein (P < 0.05). Rhodamine 123 fluorescence of polymorphonuclear-leukocytes also increased (P < 0.05). Lowered respiratory control ratios were found in daily high-iron-supplemented rats regardless of the previous iron status (P < 0.05). mtDNA damage was observed in both iron-deficient rats and rats receiving daily high-iron supplementation, compared with iron-normal rats (P < 0.05). Study 2 compared iron-deficient rats given high doses of iron (8,000 μg) either daily or every third day and found that rats given iron supplements every third day had less mtDNA damage on the second and third day after the last dose compared to daily high iron doses. Both inadequate and excessive iron (10 × nutritional need) cause significant mitochondrial malfunction. Although excess iron has been known to cause oxidative damage, the observation of oxidant-induced damage to mitochondria from iron deficiency has been unrecognized previously. Untreated iron deficiency, as well as excessive-iron supplementation, are deleterious and emphasize the importance of maintaining optimal iron intake. PMID:11854522
Does altered fractionation influence the risk of radiation-induced optic neuropathy?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandare, Niranjan; Monroe, Alan T.; Morris, Christopher G.
2005-07-15
Purpose: To analyze the parameters that influence the risk of radiation-induced optic neuropathy (RION) after radiotherapy for head-and-neck tumors. Methods and Materials: Between 1964 and 2000, 273 patients with tumors of the nasopharynx, paranasal sinuses, nasal cavity, and hard palate adenoid cystic carcinomas were treated with curative intent and had radiation fields that included the optic nerves and/or chiasm. Patients were followed for at least 1 year after radiotherapy. Results: Radiation-induced optic neuropathy developed in 32 eyes of 24 patients (9%). The 5-year rates of freedom from RION according to the total dose and once- vs. twice-daily fractionation were asmore » follows: {<=}63 Gy once daily, 95%; {<=}63 Gy twice daily, 98%; >63 Gy once daily, 78%; and >63 Gy twice daily, 91%. Multivariate analysis revealed that the total dose affected the risk of RION (p = 0.0047), with patient age (p = 0.0909), once-daily vs. twice-daily fractionation (p = 0.0684), and overall treatment time (p = 0.0972) were marginally significant. The use of adjuvant chemotherapy did not significantly influence the likelihood of developing RION. Conclusion: The likelihood of developing RION is primarily influenced by the total dose. Hyperfractionation may reduce the risk of experiencing this complication.« less
Sharma, Manju; Fields, Emma C; Todor, Dorin A
2015-01-01
To present a novel method allowing fast volumetric optimization of tandem and ovoid high-dose-rate treatments and to quantify its benefits. Twenty-seven CT-based treatment plans from 6 consecutive cervical cancer patients treated with four to five intracavitary tandem and ovoid insertions were used. Initial single-step optimized plans were manually optimized, approved, and delivered plans created with a goal to cover high-risk clinical target volume (HR-CTV) with D90 >90% and minimize rectum, bladder, and sigmoid D2cc. For the two-step optimized (TSO) plan, each single-step optimized plan was replanned adding a structure created from prescription isodose line to the existent physician delineated HR-CTV, rectum, bladder, and sigmoid. New, more rigorous dose-volume histogram constraints for the critical organs at risks (OARs) were used for the optimization. HR-CTV D90 and OAR D2ccs were evaluated in both plans. TSO plans had consistently smaller D2ccs for all three OARs while preserving HR-CTV D90. On plans with "excellent" CTV coverage, average D90 of 96% (91-102%), sigmoid, bladder, and rectum D2cc, respectively, reduced on average by 37% (16-73%), 28% (20-47%), and 27% (15-45%). Similar reductions were obtained on plans with "good" coverage, average D90 of 93% (90-99%). For plans with "inferior" coverage, average D90 of 81%, the coverage increased to 87% with concurrent D2cc reductions of 31%, 18%, and 11% for sigmoid, bladder, and rectum, respectively. The TSO can be added with minimal planning time increase but with the potential of dramatic and systematic reductions in OAR D2ccs and in some cases with concurrent increase in target dose coverage. These single-fraction modifications would be magnified over the course of four to five intracavitary insertions and may have real clinical implications in terms of decreasing both acute and late toxicities. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Marshall, Esaie; Salmon, Dominique; Bousfiha, Nadia; Togola, Yacouba; Ouedraogo, François; Santantonio, Maud; Dieng, Coumba Khadidja; Tartière, Suzanne; Emmanuelli, Xavier
2017-09-18
We aim to determine the vaccination coverage of social and healthcare workers in International sites of Samusocial, providing emergency care to homeless people, and to assess factors associated with having received necessary doses at adulthood. Data on immunization coverage of social and healthcare workers were provided by a cross-sectional survey, conducted from February to April 2015 among 252 Samusocial workers in 10 countries. Vaccination status and characteristics of participants were collected through a self-administered questionnaire. Prevalence rate ratio (PRR) of vaccination status was calculated using Poisson regression models. Among 252 Samusocial social and health workers who felt a questionnaire, median age was 39years, 42.1% were female, 88.9% were in contact with homeless beneficiaries (19.1% health workers). Overall, 90.1% of Samusocial staff felt adult vaccinations was useful and 70.2% wished to receive booster doses in future. Vaccination coverage at adulthood was satisfactory for diphtheria and poliomyelitis (96%), but low for influenza (20.8%), meningococcus (50.5%), hepatitis B (56.3%), yellow fever (58.1%), measles (81.3%) and pertussis (90.7%). The main reasons for not having received vaccination booster doses were forgetting the dates of booster doses (38.4%) and not having received the information (13.5%). In adjusted analysis, prevalence of up-to-date for vaccination schedule was 35% higher among health workers than among social workers (aPRR=1.35, 95%CI: 1.01-1.82, P=0.05) and was 56% higher among workers who had a documentary evidence of vaccination than in those who did not (aPRR=1.56, 95%CI: 1.19-2.02, P=0.001). The Samusocial International workers vaccine coverage at adulthood was insufficient and disparate by region. It is necessary to strengthen the outreach of this staff and increase immunization policy for hepatitis B, diphtheria, tetanus, and measles, as well as for yellow fever, rabies and meningococcal ACYW135 vaccines in at risk regions. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, Ricky; Teo, Peter; Kam, Michael
The aim of this study is to evaluate the deficiencies in target coverage and organ protection of 2-dimensional radiation therapy (2DRT) in the treatment of advanced T-stage (T3-4) nasopharyngeal carcinoma (NPC), and assess the extent of improvement that could be achieved with intensity modulated radiation therapy (IMRT), with special reference to of the dose to the planning organ-at-risk volume (PRV) of the brainstem and spinal cord. A dosimetric study was performed on 10 patients with advanced T-stage (T3-4 and N0-2) NPC. Computer tomography (CT) images of 2.5-mm slice thickness of the head and neck were acquired with the patient immobilizedmore » in semi-extended-head position. A 2D plan based on Ho's technique, and an IMRT plan based on a 7-coplanar portals arrangement, were established for each patient. 2DRT was planned with the field borders and shielding drawn on the simulator radiograph with reference to bony landmarks, digitized, and entered into a planning computer for reconstruction of the 3D dose distribution. The 2DRT and IMRT treatment plans were evaluated and compared with respect to the dose-volume histograms (DVHs) of the targets and the organs-at-risk (OARs), tumor control probability (TCP), and normal tissue complication probabilities (NTCPs). With IMRT, the dose coverage of the target was superior to that of 2DRT. The mean minimum dose of the GTV and PTV were increased from 33.7 Gy (2DRT) to 62.6 Gy (IMRT), and 11.9 Gy (2DRT) to 47.8 Gy (IMRT), respectively. The D{sub 95} of the GTV and PTV were also increased from 57.1 Gy (2DRT) to 67 Gy (IMRT), and 45 Gy (2DRT) to 63.6 Gy (IMRT), respectively. The TCP was substantially increased to 78.5% in IMRT. Better protection of the critical normal organs was also achieved with IMRT. The mean maximum dose delivered to the brainstem and spinal cord were reduced significantly from 61.8 Gy (2DRT) to 52.8 Gy (IMRT) and 56 Gy (2DRT) to 43.6 Gy (IMRT), respectively, which were within the conventional dose limits of 54 Gy for brainstem and of 45 Gy for spinal cord. The mean maximum doses deposited on the PRV of the brainstem and spinal cord were 60.7 Gy and 51.6 Gy respectively, which were above the conventional dose limits. For the chiasm, the mean dose maximum and the dose to 5% of its volume were reduced from 64.3 Gy (2DRT) to 53.7 Gy (IMRT) and from 62.8 Gy (2DRT) to 48.7 Gy (IMRT), respectively, and the corresponding NTCP was reduced from 18.4% to 2.1%. For the temporal lobes, the mean dose to 10% of its volume (about 4.6 cc) was reduced from 63.8 Gy (2DRT) to 55.4 Gy (IMRT) and the NTCP was decreased from 11.7% to 3.4%. The therapeutic ratio for T3-4 NPC tumors can be significantly improved with IMRT treatment technique due to improvement both in target coverage and the sparing of the critical normal organ. Although the maximum doses delivered to the brainstem and spinal cord in IMRT can be kept at or below their conventional dose limits, the maximum doses deposited on the PRV often exceed these limits due to the close proximity between the target and OARs. In other words, ideal dosimetric considerations cannot be fulfilled in IMRT planning for T3-4 NPC tumors. A compromise of the maximal dose limit to the PRV of the brainstem and spinal cord would need be accepted if dose coverage to the targets is not to be unacceptably compromised. Dosimetric comparison with 2DRT plans show that these dose limits to PRV were also frequently exceeded in 2DRT plans for locally advanced NPC. A dedicated retrospective study on the incidence of clinical injury to neurological organs in a large series of patients with T3-4 NPC treated by 2DRT may provide useful reference data in exploring how far the PRV dose constraints may be relaxed, to maximize the target coverage without compromising the normal organ function.« less
Abbas, Ahmar S; Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-05-06
Recently, volumetric-modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity-modulated fixed-field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs-at-risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed-field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient-specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single-arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2-T3 N0-N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281-601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four-field (n = 4) or five-field (n = 9) step-and-shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose-volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two-arc plans. The comparison of VMATI with fixed-field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p = 0.47), PTV mean (p = 0.12), PTV D95 and PTV V9547.5Gy (95%) (p = 0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p = 0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p = 0.04). VMATI achieved lower lung V20 (p = 0.05), whereas lung V5 (p = 0.35) and mean lung dose (p = 0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p = 5.8E-10) and MUs reduced by up to 16% (p = 0.001). Integral dose was not statistically different between the two planning techniques (p = 0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p = 0.76), PTV D95 (p = 0.95), mean PTV dose (p = 0.78), conformation number (CN) (p = 0.26), and MUs (p = 0.1). However, the treatment delivery time for VMATII increased significantly by two-fold (p = 3.0E-11) compared to VMATI. VMAT-based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single-arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumaran Nair, C; Hoffman, D; Wright, C
Purpose: We aim to evaluate a new commercial dose mimicking inverse-planning application that was designed to provide cross-platform treatment planning, for its dosimetric quality and efficiency. The clinical benefit of this application allows patients treated on O-shaped linac to receive an equivalent plan on conventional L-shaped linac as needed for workflow or machine downtime. Methods: The dose mimicking optimization process seeks to create a similar DVH of an O-shaped linac-based plans with an alternative treatment technique (IMRT or VMAT), by maintaining target conformity, and penalizing dose falloff outside the target. Ten head and neck (HN) helical delivery plans, including simplemore » and complex cases were selected for re-planning with the dose mimicking application. All plans were generated for a 6 MV beam model, using 7-field/ 9-field IMRT and VMAT techniques. PTV coverage (D1, D99 and homogeneity index [HI]), and OARs avoidance (Dmean / Dmax) were compared. Results: The resulting dose mimicked HN plans achieved acceptable PTV coverage for HI (VMAT 7.0±2.3, 7-fld 7.3±2.4, and 9-fld 7.0±2.4), D99 (98.0%±0.7%, 97.8%±0.7%, and 98.0%±0.7%), as well as D1 (106.4%±2.1%, 106.5%±2.2%, and 106.4%±2.1%), respectively. The OAR dose discrepancy varied: brainstem (2% to 4%), cord (3% to 6%), esophagus (−4% to −8%), larynx (−4% to 2%), and parotid (4% to 14%). Mimicked plans would typically be needed for 1–5 fractions of a treatment course, and we estimate <1% variance would be introduced in target coverage while maintaining comparable low dose to OARs. All mimicked plans were approved by independent physician and passed patient specific QA within our established tolerance. Conclusion: Dose mimicked plans provide a practical alternative for responding to clinical workflow issues, and provide reliability for patient treatment. The quality of dose mimicking for HN patients highly depends on the delivery technique, field numbers and angles, as well as user selection of structures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, S; Roa, D; Hanna, N
2015-06-15
Purpose: Flattening Filter Free (FFF) beams offer the potential for higher dose rates, short treatment time, and lower out of field dose. Therefore, the aim of this study was to investigate the dosimetric effects and out of field dose of Volumetric Modulated Arc Therapy (VMAT) plans using FFF vs Flattening Filtering (FF) beams for partial brain irradiation. Methods: Ten brain patients treated with a 6FF beam from a Truebeam STX were analyzed retrospectively for this study. These plans (46Gy at 2 Gy per fraction) were re-optimized for 6FFF beams using the same dose constraints as the original plans. PTV coverage,more » PTV Dmax, total MUs, and mean dose to organs-at-risk (OAR) were evaluated. In addition, the out-of-field dose for 6FF and 6FFF plans for one patient was measured on an anthropomorphic phantom. TLDs were placed inside (central axis) and outside (surface) the phantom at distances ranging from 0.5 cm to 17 cm from the field edge. Paired T-test was used for statistical analysis. Results: PTV coverage and PTV Dmax were comparable for the FF and FFF plans with 95.9% versus 95.6% and 111.2% versus 111.9%, respectively. Mean dose to the OARs were 3.7% less for FFF than FF plans (p<0.0001). Total MUs were, on average, 12.5% greater for FFF than FF plans with 481±55 MU (FFF) versus 429±50 MU (FF), p=0.0003. On average, the measured out of field dose was 24% less for FFF compared to FF, p<0.0001. A similar beam-on time was observed for the FFF and FF treatment. Conclusion: It is beneficial to use 6FFF beams for regular fractionated brain VMAT treatments. VMAT treatment plans using FFF beams can achieve comparable PTV coverage but with more OAR sparing. The out of field dose is significant less with mean reduction of 24%.« less
Dynamic simulation of motion effects in IMAT lung SBRT.
Zou, Wei; Yin, Lingshu; Shen, Jiajian; Corradetti, Michael N; Kirk, Maura; Munbodh, Reshma; Fang, Penny; Jabbour, Salma K; Simone, Charles B; Yue, Ning J; Rengan, Ramesh; Teo, Boon-Keng Kevin
2014-11-01
Intensity modulated arc therapy (IMAT) has been widely adopted for Stereotactic Body Radiotherapy (SBRT) for lung cancer. While treatment dose is optimized and calculated on a static Computed Tomography (CT) image, the effect of the interplay between the target and linac multi-leaf collimator (MLC) motion is not well described and may result in deviations between delivered and planned dose. In this study, we investigated the dosimetric consequences of the inter-play effect on target and organs at risk (OAR) by simulating dynamic dose delivery using dynamic CT datasets. Fifteen stage I non-small cell lung cancer (NSCLC) patients with greater than 10 mm tumor motion treated with SBRT in 4 fractions to a dose of 50 Gy were retrospectively analyzed for this study. Each IMAT plan was initially optimized using two arcs. Simulated dynamic delivery was performed by associating the MLC leaf position, gantry angle and delivered beam monitor units (MUs) for each control point with different respiratory phases of the 4D-CT using machine delivery log files containing time stamps of the control points. Dose maps associated with each phase of the 4D-CT dose were calculated in the treatment planning system and accumulated using deformable image registration onto the exhale phase of the 4D-CT. The original IMAT plans were recalculated on the exhale phase of the CT for comparison with the dynamic simulation. The dose coverage of the PTV showed negligible variation between the static and dynamic simulation. There was less than 1.5% difference in PTV V95% and V90%. The average inter-fraction and cumulative dosimetric effects among all the patients were less than 0.5% for PTV V95% and V90% coverage and 0.8 Gy for the OARs. However, in patients where target is close to the organs, large variations were observed on great vessels and bronchus for as much as 4.9 Gy and 7.8 Gy. Limited variation in target dose coverage and OAR constraints were seen for each SBRT fraction as well as over all four fractions. Large dose variations were observed on critical organs in patients where these organs were closer to the target.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallardo, N; Maneru, F; Fuentemilla, N
2015-06-15
Purpose: dosimetric comparison of 3DCRT and IMRT in 9 esophageal cancer. The aim of this paper is to know which of these two techniques is dosimetrically more favorable dosimetrically at both the CTV coverage and dose obtained in the relevant organs at risk, in this case, lungs and heart, as the spinal cord received in all cases below 45 Gy. Methods: we chose 9 patients from our center (CHN) with the same type of esophageal cancer and in which the prescribed dose was the same, 54 Gy. For these treatments we have used the same fields and the same anglesmore » (AP (0 °), OPD (225°–240°) and OPI (125°–135°)).All plans have been implemented using Eclipse (version 11.0) with AAA( Analytical Anisotropic Algorithm )(Version 11.0.31). Results: To analyze the coverage of the CTV, we have evaluated the D99% and found that the average dose received by 99% of CTV with IMRT is 53.8 ± 0.4 Gy (99.6% of the prescribed dose) and the mean value obtained with 3DCRT is 52.3 ± 0.6 Gy (96.8% of the prescribed dose).The last data analyzed was the D2% of PTV, a fact that gives us information on the maximum dose received by our PTV. D2% of the PTV for IMRT planning is 55.4 ± 0.4 Gy (102.6% of the prescribed dose) and with 3DCRT is 56.8 ± 0.7 Gy (105.2% of the prescribed dose).All parameters analyzed at risk organs (V30, V40, V45 and V50 for the case of heart and V5, V10, V15 and V20 for the case of the lungs) provide us irradiated volume percentages lower in IMRT than 3DCRT. Conclusion: IMRT provides a considerable improvement in the coverage of the CTV and the doses to organs at risk.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, P; Zhuang, T; Magnelli, A
2015-06-15
Purpose It was recommended to use the prescription of 54 Gy/3 with heterogeneity corrections for previously established dose scheme of 60 Gy/3 with homogeneity calculation. This study is to investigate dose coverage for the internal target volume (ITV) with and without heterogeneity correction. Methods Thirty patients who received stereotactic body radiotherapy (SBRT) to a dose of 60 Gy in 3 fractions with homogeneous planning for early stage non-small-cell lung cancer (NSCLC) were selected. ITV was created either from 4DCT scans or a fusion of multi-phase respiratory scans. Planning target volume (PTV) was a 5 mm expansion of the ITV. Formore » this study, we recalculated homogeneous clinical plans using heterogeneity corrections with monitor units set as clinically delivered. All plans were calculated with 3 mm dose grids and collapsed cone convolution algorithm. To account for uncertainties from tumor delineation and image-guided radiotherapy, a structure ITV2mm was created by expanding ITV with 2 mm margins. Dose coverage to the PTV, ITV and ITV2mm were compared with a student paired t-test. Results With heterogeneity corrections, the PTV V60Gy decreased by 10.1% ± 18.4% (p<0.01) while the maximum dose to the PTV increased by 3.7 ± 4.3% (p<0.01). With and without corrections, D99% was 65.8 ± 4.0 Gy and 66.7 ± 4.8 Gy (p=0.15) for the ITV, and 63.9 ± 3.4 Gy and 62.9 ± 4.6 Gy for the ITV2mm (p=0.22), respectively. The mean dose to the ITV and ITV2mm increased 3.6% ± 4.7% (p<0.01) and 2.3% ± 5.2% (p=0.01) with heterogeneity corrections. Conclusion After heterogeneity correction, the peripheral coverage of the PTV decreased to approximately 54 Gy, but D99% of the ITV and ITV2mm was unchanged and the mean dose to the ITV and ITV2mm was increased. Clinical implication of these results requires more investigation.« less
Palache, Abraham; Oriol-Mathieu, Valerie; Fino, Mireli; Xydia-Charmanta, Margarita
2015-10-13
Seasonal influenza is an important disease which results in 250,000-500,000 annual deaths worldwide. Global targets for vaccination coverage rates (VCRs) in high-risk groups are at least 75% in adults ≥65 years and increased coverage in other risk groups. The International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply (IFPMA IVS) International Task Force developed a survey methodology in 2008, to assess the global distribution of influenza vaccine doses as a proxy for VCRs. This paper updates the previous survey results on absolute numbers of influenza vaccine doses distributed between 2004 and 2013 inclusive, and dose distribution rates per 1000 population, and provides a qualitative assessment of the principal enablers and barriers to seasonal influenza vaccination. The two main findings from the quantitative portion of the survey are the continued negative trend for dose distribution in the EURO region and the perpetuation of appreciable differences in scale of dose distribution between WHO regions, with no observed convergence in the rates of doses distributed per 1000 population over time. The main findings from the qualitative portion of the survey were that actively managing the vaccination program in real-time and ensuring political commitment to vaccination are important enablers of vaccination, whereas insufficient access to vaccination and lack of political commitment to seasonal influenza vaccination programs are likely contributing to vaccination target failures. In all regions of the world, seasonal influenza vaccination is underutilized as a public health tool. The survey provides evidence of lost opportunity to protect populations against potentially serious influenza-associated disease. We call on the national and international public health communities to re-evaluate their political commitment to the prevention of the annual influenza disease burden and to develop a systematic approach to improve vaccine distribution equitably. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H; Cape Breton Cancer Centre, Sydney, NS
Purpose: To perform the comparison of dose distributions and dosevolume- histograms generated by VMAT and conventional field-in-field technique for left-sided breast and chestwall cancers; to determine whether VMAT offers more dosimetric benefits than does the field-in-field technique. Methods: All VMAT and field-in-filed plans were produced in Eclipse(version 10). Five plans were generated for left-sided breast and leftsided chestwall with supraclavicular nodes, respectively. A clockwise arc (CW) and a counter-clockwise arc (CCW) were used with start and stop angles being 310o±10o and 140o±10o. Collimator angles were 30o for CW and 330o for CCW. The conformity index (CI) is the ratio ofmore » V95% over PTV. The homogeneity index (HI) is the ratio of the difference between D2% and D98% over the prescribed dose. The V5, as an indicator of low dose bath to organs-at-risk, was used for ipsilateral lung, heart, contralateral lung, and contralateral breast. The V20, as an indicator of radiation pneumonitis, was used for ipsilateral lung. Results: Breast/chestwall VMAT delivers much higher low dose bath to ipsilateral lung, contralateral lung and contralateral breast/chestwall for both intact breast and chestwall with nodes. V5 for heart is increased in VMAT plans. V20 for ipsilateral lung is lower in VMAT plans. PTV coverage is similar for both techniques. For one particular chestwall patient with supraclavicular and internal mammary nodes, VMAT offers superior dose coverage of PTVs with slightly more low-dose-wash to heart, contralateral lung and contralateral breast. Conclusion: This study indicates that there is generally no benefit using VMAT for left-sided intact breast, due to large low-dose-bath (5Gy) to normal tissues with insignificant improvement in PTV coverage. Dosimetric benefits will be seen in VMAT plans for some chestwall patients with large size, and/or internal mammary nodes, etc. Whether a chestwall patient is treated with VMAT should be carefully analyzed on an individual basis.« less
Haas, Wolfgang; Gearinger, Lynne S; Hesje, Christine K; Sanfilippo, Christine M; Morris, Timothy W
2012-05-01
Bacterial conjunctivitis is a contagious infection of the surface of the eye usually treated empirically with topical antibiotics. Since the etiologic agent is rarely identified, it is important to monitor which bacteria cause conjunctivitis and determine their antibacterial resistance profiles. A total of 496 bacterial samples were isolated during a randomized, double-masked, vehicle-controlled, parallel-group study conducted in the United States with besifloxacin ophthalmic suspension 0.6% dosed twice daily. Species were determined by standard biochemical and/or molecular identification methods. Minimum inhibitory concentrations were determined according to Clinical and Laboratory Standards Institute standards. The most prevalent species was Haemophilus influenzae, followed by Staphylococcus epidermidis, Staphylococcus aureus, the Streptococcus mitis group, and Streptococcus pneumoniae. One species identified in this study, which was not previously noted as a common cause of bacterial conjunctivitis, was Dolosigranulum pigrum. Ampicillin resistance was common among H. influenzae isolates, while macrolide resistance was high among S. pneumoniae, S. epidermidis, and S. aureus. The latter two species also included a number of isolates resistant to methicillin and ciprofloxacin. Antibiotic resistance among isolates remains a concern and the appearance of an emerging ocular pathogen, D. pigrum, suggests the need for continued observation. The topical ophthalmic fluoroquinolones continue to provide a good balance of low to moderate (i.e., manageable) levels of resistance plus broad-spectrum coverage for empiric treatment of ocular infections.
Central Nervous System Medication Burden and Serious Falls in Older Nursing Home Residents
Hanlon, Joseph T.; Zhao, Xinhua; Naples, Jennifer G.; Aspinall, Sherrie L.; Perera, Subashan; Nace, David A.; Castle, Nicholas G.; Greenspan, Susan L.; Thorpe, Carolyn T.
2016-01-01
Objectives To examine the association between CNS medication burden and serious falls in those with a recent fall history. Design Nested-case control study; cases matched to four controls by age, gender, and date. Setting US nursing homes Participants 5,556 residents age ≥ 65 with a recent fall history admitted to a nursing home between 1/1–9/30/2010 and followed until discharge, death, or 12/31/2010. Measurements Outcome was serious falls as per Medicare Part A and B ICD/CPT codes. CNS burden, from Medicare Part D data, was calculated by dividing the daily dose of each CNS agent (i.e., specific antidepressants, antiepileptic, antipsychotic, benzodiazepine and opioid receptor agonists) received during the six days prior to the index (outcome) date by the minimum effective geriatric daily dose and summing the results across medications. Results There were 367 cases and 1468 matched controls. Those taking 3+ CNS standardized daily doses were more likely to have a serious fall than those not taking any CNS medications (Adjusted Odds Ratio 1.83; 95% confidence interval 1.35–2.48). There was no significant difference in fall risk for residents taking >0 to <3 CNS standardized daily doses compared to residents taking no CNS medications (Adjusted Odds Ratio 0.85; 95% CI 0.63–1.15). Conclusion CNS medication burden, approximately 3+ standardized daily doses, was associated with an increased risk of serious falls in nursing home residents with recent fall. Clinicians should be vigilant for opportunities to discontinue or decrease the doses of individual CNS medications and/or consider non-pharmacological alternatives. Such interventions that reduce use of CNS medications in nursing homes could reduce fall rates but further research is needed to confirm this. PMID:28152179
Furuta, Takahisa; Shimatani, Tomohiko; Sugimoto, Mitsushige; Ishihara, Shunji; Fujiwara, Yasuhiro; Kusano, Motoyasu; Koike, Tomoyuki; Hongo, Michio; Chiba, Tsutomu; Kinoshita, Yoshikazu
2011-11-01
Some non-erosive reflux disease (NERD) and reflux esophagitis (RE) patients are unresponsive to a proton pump inhibitor (PPI) at standard dose. We investigated the predictive marker of the efficacy of PPI for GERD patients including NERD and RE treated with standard and increased doses of a PPI. Patients with symptomatic gastroesophageal reflux disease (GERD) (NERD and RE) were treated with rabeprazole (RPZ) 10 mg once daily for 4 weeks. The RPZ dosage was increased to 10 mg twice daily for an additional 2 weeks and again to 20 mg twice daily for another 2 weeks if heartburn was not relieved. Baseline characteristics and efficacy of RPZ were assessed on the basis of a heartburn diary and frequency scale for symptoms of GERD (FSSG). Complete heartburn relief rates after 4 weeks were 42.5% (31/73) and 67.9% (19/28) in NERD and RE groups, respectively, which rose to 68.9 and 91.7% after dose escalation. Multivariate analysis revealed that parameters associated with resistance to RPZ 10 mg once daily were female, non-smoking, frequent heartburn, low score for question 4 (Q4) of the FSSG (subconsciously rubbing the chest), and high scores for Q3 (heavy stomach after meal) and Q7 (unusual sensation in the throat). Frequent heartburn and a high score for Q7 were associated with resistance to RPZ 20 mg twice daily. FSSG scores of patients resistant to RPZ were significantly higher in comparison with responders before and during treatment. FSSG could predict response to a PPI for symptomatic GERD. Increase of RPZ dose is useful for treatment of GERD refractory to the standard dose of RPZ.
Determinants of geographic inequalities in HPV vaccination in the most populated region of France.
Héquet, Delphine; Rouzier, Roman
2017-01-01
In France, there are recommendations and reimbursements for human papillomavirus (HPV) vaccination but no HPV vaccination programs. Therefore, vaccination is largely determined by parents' initiative, which can lead to inequalities. The objective of this study was to determine the factors associated with poorer vaccination coverage rates in the most populated region of France. The data of this study were obtained from the National Health Insurance between 2011 and 2013. Correlations between vaccination initiation rate (at least 1 dose reimbursed) and socio-demographic/cultural factors were assessed using Pearson's product-moment correlation coefficient. Multivariate analyses were performed using logistic regression. In total, 121,636 girls received at least one HPV vaccine dose. The vaccination rate for girls born from 1996 to 1999 was 18.7%. Disparities in vaccination coverage rates were observed between the 8 departments of the region, ranging from 12.9% to 22.6%. At the department level, unemployment, proportion of immigrants and foreigners, and coverage by CMU health insurance ("Couverture Maladie Universelle", a health insurance plan for those who are not otherwise covered through business or employment and who have a low income) were significantly inversely correlated with vaccination rates, whereas urban residence, medical density, income and use of medical services were not related to coverage. In the multivariate model, only the percentage of foreigners remained independently associated with lower vaccination coverage. At the individual level, the use of medical services was a strong driver of HPV vaccination initiation. We observed geographic disparities in HPV vaccination initiation coverage. Even if no clear factor was identified as a vaccination determinant, we observed a failure of vaccination only based on parents' initiative. Therefore, an organized policy on HPV vaccination, such as school-based programs, can help improve coverage rates.