Sample records for damaged tendon system

  1. Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability.

    PubMed

    Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza

    2014-11-01

    To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair

    PubMed Central

    Zhang, Qing-Song; Liu, Sen; Zhang, Qiuyang; Xue, Yun; Ge, Dongxia; O'Brien, Michael J.; Savoie, Felix H.; You, Zongbing

    2012-01-01

    Objectives. The objective of this study was to compare the damage to the rotator cuff tendons caused by four different anchor systems. Methods. 20 cadaveric human shoulder joints were used for transtendon insertion of four anchor systems. The Healix Peek, Fastin RC, Bio-Corkscrew Suture, and Healix Transtend anchors were inserted through the tendons using standard transtendon procedures. The areas of tendon damage were measured. Results. The areas of tendon damage (mean ± standard deviation, n = 7) were 29.1 ± 4.3 mm2 for the Healix Peek anchor, 20.4 ± 2.3 mm2 for the Fastin RC anchor, 23.4 ± 1.2 mm2 for the Bio-Corkscrew Suture anchor, 13.7 ± 3.2 mm2 for the Healix Transtend anchor inserted directly, and 9.1 ± 2.1 mm2 for the Healix Transtend anchor inserted through the Percannula system (P < 0.001 or P < 0.001, compared to other anchors). Conclusions. In a cadaver transtendon rotator cuff repair model, smaller anchors caused less damage to the tendon tissues. The Healix Transtend implant system caused the least damage to the tendon tissues. Our findings suggest that smaller anchors should be considered when performing transtendon procedures to repair partial rotator cuff tears. PMID:22811923

  3. Fatigue loading of tendon

    PubMed Central

    Shepherd, Jennifer H; Screen, Hazel R C

    2013-01-01

    Tendon injuries, often called tendinopathies, are debilitating and painful conditions, generally considered to develop as a result of tendon overuse. The aetiology of tendinopathy remains poorly understood, and whilst tendon biopsies have provided some information concerning tendon appearance in late-stage disease, there is still little information concerning the mechanical and cellular events associated with disease initiation and progression. Investigating this in situ is challenging, and numerous models have been developed to investigate how overuse may generate tendon fatigue damage and how this may relate to tendinopathy conditions. This article aims to review these models and our current understanding of tendon fatigue damage. We review the strengths and limitations of different methodologies for characterizing tendon fatigue, considering in vitro methods that adopt both viable and non-viable samples, as well as the range of different in vivo approaches. By comparing data across model systems, we review the current understanding of fatigue damage development. Additionally, we compare these findings with data from tendinopathic tissue biopsies to provide some insights into how these models may relate to the aetiology of tendinopathy. Fatigue-induced damage consistently highlights the same microstructural, biological and mechanical changes to the tendon across all model systems and also correlates well with the findings from tendinopathic biopsy tissue. The multiple testing routes support matrix damage as an important contributor to tendinopathic conditions, but cellular responses to fatigue appear complex and often contradictory. PMID:23837793

  4. Electromechanical impedance-based health diagnosis for tendon and anchorage zone in a nuclear containment structure

    NASA Astrophysics Data System (ADS)

    Min, Jiyoung; Shim, Hyojin; Yun, Chung-Bang

    2012-04-01

    For a nuclear containment structure, the structural health monitoring is essential because of its high potential risk and grave social impact. In particular, the tendon and anchorage zone are to be monitored because they are under high tensile or compressive stress. In this paper, a method to monitor the tendon force and the condition of the anchorage zone is presented by using the impedance-based health diagnosis system. First, numerical simulations were conducted for cases with various loose tensile forces on the tendon as well as damages on the bearing plate and concrete structure. Then, experimental studies were carried out on a scaled model of the anchorage system. The relationship between the loose tensile force and the impedance-based damage index was analyzed by a regression analysis. When a structure gets damaged, the damage index increases so that the status of damage can be identified. The results of the numerical and experimental studies indicate a big potential of the proposed impedance-based method for monitoring the tendon and anchorage system.

  5. How Obesity Affects Tendons?

    PubMed

    Abate, Michele; Salini, Vincenzo; Andia, Isabel

    Several epidemiological and clinical observations have definitely demonstrated that obesity has harmful effects on tendons. The pathogenesis of tendon damage is multi-factorial. In addition to overload, attributable to the increased body weight, which significantly affects load-bearing tendons, systemic factors play a relevant role. Several bioactive peptides (chemerin, leptin, adiponectin and others) are released by adipocytes, and influence tendon structure by means of negative activities on mesenchymal cells. The ensuing systemic state of chronic, sub-clinic, low-grade inflammation can damage tendon structure. Metabolic disorders (diabetes, impaired glucose tolerance, and dislipidemia), frequently associated with visceral adiposity, are concurrent pathogenetic factors. Indeed, high glucose levels increase the formation of Advanced Glycation End-products, which in turn form stable covalent cross-links within collagen fibers, modifying their structure and functionality.Sport activities, so useful for preventing important cardiovascular complications, may be detrimental for tendons if they are submitted to intense acute or chronic overload. Therefore, two caution rules are mandatory: first, to engage in personalized soft training program, and secondly to follow regular check-up for tendon pathology.

  6. Freezing does not alter multiscale tendon mechanics and damage mechanisms in tension.

    PubMed

    Lee, Andrea H; Elliott, Dawn M

    2017-12-01

    It is common in biomechanics to use previously frozen tissues, where it is assumed that the freeze-thaw process does not cause consequential mechanical or structural changes. We have recently quantified multiscale tendon mechanics and damage mechanisms using previously frozen tissue, where damage was defined as an irreversible change in the microstructure that alters the macroscopic mechanical parameters. Because freezing has been shown to alter tendon microstructures, the objective of this study was to determine if freezing alters tendon multiscale mechanics and damage mechanisms. Multiscale testing using a protocol that was designed to evaluate tendon damage (tensile stress-relaxation followed by unloaded recovery) was performed on fresh and previously frozen rat tail tendon fascicles. At both the fascicle and fibril levels, there was no difference between the fresh and frozen groups for any of the parameters, suggesting that there is no effect of freezing on tendon mechanics. After unloading, the microscale fibril strain fully recovered, and interfibrillar sliding only partially recovered, suggesting that the tendon damage is localized to the interfibrillar structures and that mechanisms of damage are the same in both fresh and previously frozen tendons. © 2017 New York Academy of Sciences.

  7. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    PubMed

    Janta, Iustina; Morán, Julio; Naredo, Esperanza; Nieto, Juan Carlos; Uson, Jacqueline; Möller, Ingrid; Bong, David; Bruyn, George A W; D Agostino, Maria Antonietta; Filippucci, Emilio; Hammer, Hilde Berner; Iagnocco, Annamaria; Terslev, Lene; González, Jorge Murillo; Mérida, José Ramón; Carreño, Luis

    2016-06-01

    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.

  8. Greater inadvertent muscle damage in direct anterior approach when compared with the direct superior approach for total hip arthroplasty.

    PubMed

    Amanatullah, D F; Masini, M A; Roger, D J; Pagnano, M W

    2016-08-01

    We wished to quantify the extent of soft-tissue damage sustained during minimally invasive total hip arthroplasty through the direct anterior (DA) and direct superior (DS) approaches. In eight cadavers, the DA approach was performed on one side, and the DS approach on the other, a single brand of uncemented hip prosthesis was implanted by two surgeons, considered expert in their surgical approaches. Subsequent reflection of the gluteus maximus allowed the extent of muscle and tendon damage to be measured and the percentage damage to each anatomical structure to be calculated. The DA approach caused substantially greater damage to the gluteus minimus muscle and tendon when compared with the DS approach (t-test, p = 0.049 and 0.003, respectively). The tensor fascia lata and rectus femoris muscles were damaged only in the DA approach. There was no difference in the amount of damage to the gluteus medius muscle and tendon, piriformis tendon, obturator internus tendon, obturator externus tendon or quadratus femoris muscle between approaches. The posterior soft-tissue releases of the DA approach damaged the gluteus minimus muscle and tendon, piriformis tendon and obturator internus tendon. The DS approach caused less soft-tissue damage than the DA approach. However the clinical relevance is unknown. Further clinical outcome studies, radiographic evaluation of component position, gait analyses and serum biomarker levels are necessary to evaluate and corroborate the safety and efficacy of the DS approach. Cite this article: Bone Joint J 2016;98-B1036-42. ©2016 The British Editorial Society of Bone & Joint Surgery.

  9. Delayed Exercise Promotes Remodeling in Sub-Rupture Fatigue Damaged Tendons

    PubMed Central

    Bell, R.; Boniello, M.R.; Gendron, N.R.; Flatow, E.L.; Andarawis-Puri, N.

    2015-01-01

    Tendinopathy is a common musculoskeletal injury whose treatment is limited by ineffective therapeutic interventions. Previously we have shown that tendons ineffectively repair early sub-rupture fatigue damage. In contrast, physiological exercise has been shown to promote remodeling of healthy tendons but its utility as a therapeutic to promote repair of fatigue damaged tendons remains unknown. Therefore, the objective of this study was to assess the utility of exercise initiated 1 and 14 days after onset of fatigue damage to promote structural repair in fatigue damaged tendons. We hypothesized that exercise initiated 14 days after fatigue loading would promote remodeling as indicated by a decrease in area of collagen matrix damage, increased procollagen I and decorin, while decreasing proteins indicative of tendinopathy. Rats engaged in 6-week exercise for 30 min/day or 60 min/day starting 1 or 14 days after fatigue loading. Initiating exercise 1-day after onset of fatigue injury led to exacerbation of matrix damage, particularly at the tendon insertion. Initiating exercise 14 days after onset of fatigue injury led to remodeling of damaged regions in the midsubstance and collagen synthesis at the insertion. Physiological exercise applied after the initial biological response to injury has dampened can potentially promote remodeling of damaged tendons. PMID:25732052

  10. Tendon injuries of the hand

    PubMed Central

    Schöffl, Volker; Heid, Andreas; Küpper, Thomas

    2012-01-01

    Tendon injuries are the second most common injuries of the hand and therefore an important topic in trauma and orthopedic patients. Most injuries are open injuries to the flexor or extensor tendons, but less frequent injuries, e.g., damage to the functional system tendon sheath and pulley or dull avulsions, also need to be considered. After clinical examination, ultrasound and magnetic resonance imaging have proved to be important diagnostic tools. Tendon injuries mostly require surgical repair, dull avulsions of the distal phalanges extensor tendon can receive conservative therapy. Injuries of the flexor tendon sheath or single pulley injuries are treated conservatively and multiple pulley injuries receive surgical repair. In the postoperative course of flexor tendon injuries, the principle of early passive movement is important to trigger an “intrinsic” tendon healing to guarantee a good outcome. Many substances were evaluated to see if they improved tendon healing; however, little evidence was found. Nevertheless, hyaluronic acid may improve intrinsic tendon healing. PMID:22720265

  11. Achilles tendons from decorin- and biglycan-null mouse models have inferior mechanical and structural properties predicted by an image-based empirical damage model

    PubMed Central

    Gordon, J.A.; Freedman, B.R.; Zuskov, A.; Iozzo, R.V.; Birk, D.E.; Soslowsky, L.J.

    2015-01-01

    Achilles tendons are a common source of pain and injury, and their pathology may originate from aberrant structure function relationships. Small leucine rich proteoglycans (SLRPs) influence mechanical and structural properties in a tendon-specific manner. However, their roles in the Achilles tendon have not been defined. The objective of this study was to evaluate the mechanical and structural differences observed in mouse Achilles tendons lacking class I SLRPs; either decorin or biglycan. In addition, empirical modeling techniques based on mechanical and image-based measures were employed. Achilles tendons from decorin-null (Dcn−/−) and biglycan-null (Bgn−/−) C57BL/6 female mice (N=102) were used. Each tendon underwent a dynamic mechanical testing protocol including simultaneous polarized light image capture to evaluate both structural and mechanical properties of each Achilles tendon. An empirical damage model was adapted for application to genetic variation and for use with image based structural properties to predict tendon dynamic mechanical properties. We found that Achilles tendons lacking decorin and biglycan had inferior mechanical and structural properties that were age dependent; and that simple empirical models, based on previously described damage models, were predictive of Achilles tendon dynamic modulus in both decorin- and biglycan-null mice. PMID:25888014

  12. Achilles tendons from decorin- and biglycan-null mouse models have inferior mechanical and structural properties predicted by an image-based empirical damage model.

    PubMed

    Gordon, J A; Freedman, B R; Zuskov, A; Iozzo, R V; Birk, D E; Soslowsky, L J

    2015-07-16

    Achilles tendons are a common source of pain and injury, and their pathology may originate from aberrant structure function relationships. Small leucine rich proteoglycans (SLRPs) influence mechanical and structural properties in a tendon-specific manner. However, their roles in the Achilles tendon have not been defined. The objective of this study was to evaluate the mechanical and structural differences observed in mouse Achilles tendons lacking class I SLRPs; either decorin or biglycan. In addition, empirical modeling techniques based on mechanical and image-based measures were employed. Achilles tendons from decorin-null (Dcn(-/-)) and biglycan-null (Bgn(-/-)) C57BL/6 female mice (N=102) were used. Each tendon underwent a dynamic mechanical testing protocol including simultaneous polarized light image capture to evaluate both structural and mechanical properties of each Achilles tendon. An empirical damage model was adapted for application to genetic variation and for use with image based structural properties to predict tendon dynamic mechanical properties. We found that Achilles tendons lacking decorin and biglycan had inferior mechanical and structural properties that were age dependent; and that simple empirical models, based on previously described damage models, were predictive of Achilles tendon dynamic modulus in both decorin- and biglycan-null mice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The mitochondria targeted antioxidant MitoQ protects against fluoroquinolone-induced oxidative stress and mitochondrial membrane damage in human Achilles tendon cells.

    PubMed

    Lowes, Damon A; Wallace, Carol; Murphy, Michael P; Webster, Nigel R; Galley, Helen F

    2009-04-01

    Tendinitis and tendon rupture during treatment with fluoroquinolone antibiotics is thought to be mediated via oxidative stress. This study investigated whether ciprofloxacin and moxifloxacin cause oxidative stress and mitochondrial damage in cultured normal human Achilles' tendon cells and whether an antioxidant targeted to mitochondria (MitoQ) would protect against such damage better than a non-mitochondria targeted antioxidant. Human tendon cells from normal Achilles' tendons were exposed to 0-0.3 mM antibiotic for 24 h and 7 days in the presence of 1 microM MitoQ or an untargeted form, idebenone. Both moxifloxacin and ciprofloxacin resulted in up to a 3-fold increase in the rate of oxidation of dichlorodihydrofluorescein, a marker of general oxidative stress in tenocytes (p<0.0001) and loss of mitochondrial membrane permeability (p<0.001). In cells treated with MitoQ the oxidative stress was less and mitochondrial membrane potential was maintained. Mitochondrial damage to tenocytes during fluoroquinolone treatment may be involved in tendinitis and tendon rupture.

  14. A Clinical, Biological, and Biomaterials Perspective into Tendon Injuries and Regeneration

    PubMed Central

    Walden, Grace; Liao, Xin; Donell, Simon; Raxworthy, Mike J.; Riley, Graham P.

    2017-01-01

    Tendon injury is common and debilitating, and it is associated with long-term pain and ineffective healing. It is estimated to afflict 25% of the adult population and is often a career-ending disease in athletes and racehorses. Tendon injury is associated with high morbidity, pain, and long-term suffering for the patient. Due to the low cellularity and vascularity of tendon tissue, once damage has occurred, the repair process is slow and inefficient, resulting in mechanically, structurally, and functionally inferior tissue. Current treatment options focus on pain management, often being palliative and temporary and ending in reduced function. Most treatments available do not address the underlying cause of the disease and, as such, are often ineffective with variable results. The need for an advanced therapeutic that addresses the underlying pathology is evident. Tissue engineering and regenerative medicine is an emerging field that is aimed at stimulating the body's own repair system to produce de novo tissue through the use of factors such as cells, proteins, and genes that are delivered by a biomaterial scaffold. Successful tissue engineering strategies for tendon regeneration should be built on a foundation of understanding of the molecular and cellular composition of healthy compared with damaged tendon, and the inherent differences seen in the tissue after disease. This article presents a comprehensive clinical, biological, and biomaterials insight into tendon tissue engineering and regeneration toward more advanced therapeutics. PMID:27596929

  15. Muscle-Tendon Unit Properties during Eccentric Exercise Correlate with the Creatine Kinase Response

    PubMed Central

    Hicks, Kirsty M.; Onambele-Pearson, Gladys L.; Winwood, Keith; Morse, Christopher I.

    2017-01-01

    Aim: The aim of this paper was to determine whether; (1) patella tendon stiffness, (2) the magnitude of vastus lateralis fascicle lengthening, and (3) eccentric torque correlate with markers of exercise induced muscle damage. Method: Combining dynamometry and ultrasonography, patella tendon properties and vastus lateralis architectural properties were measured pre and during the first of six sets of 12 maximal voluntary eccentric knee extensions. Maximal isometric torque loss and creatine kinase activity were measured pre-damage (−48 h), 48, 96, and 168 h post-damage as markers of exercise-induced muscle damage. Results: A significant increase in creatine kinase (883 ± 667 UL) and a significant reduction in maximal isometric torque loss (21%) was reported post-eccentric contractions. Change in creatine kinase from pre to peak significantly correlated with the relative change in vastus lateralis fascicle length during eccentric contractions (r = 0.53, p = 0.02) and with eccentric torque (r = 0.50, p = 0.02). Additionally, creatine kinase tended to correlate with estimated patella tendon lengthening during eccentric contractions (p < 0.10). However, creatine kinase did not correlate with resting measures of patella tendon properties or vastus lateralis properties. Similarly, torque loss did not correlate with any patella tendon or vastus lateralis properties at rest or during eccentric contractions. Conclusion: The current study demonstrates that the extent of fascicle strain during eccentric contractions correlates with the magnitude of the creatine kinase response. Although at rest, there is no relationship between patella tendon properties and markers of muscle damage; during eccentric contractions however, the patella tendon may play a role in the creatine kinase response following EIMD. PMID:28974931

  16. Health monitoring of prestressing tendons in post-tensioned concrete structures

    NASA Astrophysics Data System (ADS)

    Salamone, Salvatore; Bartoli, Ivan; Nucera, Claudio; Phillips, Robert; Lanza di Scalea, Francesco

    2011-04-01

    Currently 90% of bridges built in California are post-tensioned box-girder. In such structures the steel tendons are the main load-carrying components. The loss of prestress, as well as the presence of defects or the tendon breakage, can be catastrophic for the entire structure. Unfortunately, today there is no well-established method for the monitoring of prestressing (PS) tendons that can provide simultaneous information related to the presence of defects and the level of prestress in a continuous, real time manner. If such a monitoring system were available, considerable savings would be achieved in bridge maintenance since repairs would be implemented in a timely manner without traffic disruptions. This paper presents a health monitoring system for PS tendons in post-tensioned structures of interest to Caltrans. Such a system uses ultrasonic guided waves and embedded sensors to provide simultaneously and in real time, (a) measurements of the level of applied prestress, and (b) defect detection at early grow stages. The proposed PS measurement technique exploits the sensitivity of ultrasonic waves to the inter-wire contact developing in a multi-wire strand as a function of prestress level. In particular the nonlinear ultrasonic behavior of the tendon under changing levels of prestress is monitored by tracking higher-order harmonics at (nω) arising under a fundamental guided-wave excitation at (ω). Moreover this paper also present real-time damage detection and location in post-tensioned bridge joints using Acoustic Emission techniques. Experimental tests on large-scale single-tendon PT joint specimens, subjected to multiple load cycles, will be presented to validate the monitoring of PS loads (through nonlinear ultrasonic probing) and the monitoring of damage progression and location (through acoustic emission techniques). Issues and potential for the use of such techniques to monitor post-tensioned bridges in the field will be discussed.

  17. Probing multi-scale mechanical damage in connective tissues using X-ray diffraction.

    PubMed

    Bianchi, Fabio; Hofmann, Felix; Smith, Andrew J; Thompson, Mark S

    2016-11-01

    The accumulation of microstructural collagen damage following repetitive loading is linked to painful and debilitating tendon injuries. As a hierarchical, semi-crystalline material, collagen mechanics can be studied using X-ray diffraction. The aim of the study was to describe multi-structural changes in tendon collagen following controlled plastic damage (5% permanent strain). We used small angle X-ray scattering (SAXS) to interrogate the spacing of collagen molecules within a fibril, and wide angle X-ray scattering (WAXS) to measure molecular strains under macroscopic loading. Simultaneous recordings of SAXS and WAXS patterns, together with whole-tissue strain in physiologically hydrated rat-tail tendons were made during increments of in situ tensile loading. Results showed that while tissue level modulus was unchanged, fibril modulus decreased significantly, and molecular modulus significantly increased. Further, analysis of higher order SAXS peaks suggested structural changes in the gap and overlap regions, possibly localising the damage to molecular cross-links. Our results provide new insight into the fundamental damage processes at work in collagenous tissues and point to new directions for their mitigation and repair. This article reports the first in situ loading synchrotron studies on mechanical damage in collagenous tissues. We provide new insight into the nano- and micro-structural mechanisms of damage processes. Pre-damaged tendons showed differential alteration of moduli at macro, micro and nano-scales as measured using X-ray scattering techniques. Detailed analysis of higher order diffraction peaks suggested damage is localised to molecular cross-links. The results are consistent with previous X-ray scattering studies of tendons and also with recent thermal stability studies on damaged material. Detailed understanding of damage mechanisms is essential in the development of new therapies promoting tissue repair. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. Cell-laden composite suture threads for repairing damaged tendons.

    PubMed

    Costa-Almeida, Raquel; Domingues, Rui M A; Fallahi, Afsoon; Avci, Huseyin; Yazdi, Iman K; Akbari, Mohsen; Reis, Rui L; Tamayol, Ali; Gomes, Manuela E; Khademhosseini, Ali

    2018-04-01

    Tendons have limited regenerative capacity due to their low cellularity and hypovascular nature, which results in poor clinical outcomes of presently used therapies. As tendon injuries are often observed in active adults, it poses an increasing socio-economic burden on healthcare systems. Currently, suture threads are used during surgical repair to anchor the tissue graft or to connect injured ends. Here, we created composite suture threads coated with a layer of cell-laden hydrogel that can be used for bridging the injured tissue aiming at tendon regeneration. In addition, the fibres can be used to engineer 3-dimensional constructs through textile processes mimicking the architecture and mechanical properties of soft tissues, including tendons and ligaments. Encapsulated human tendon-derived cells migrated within the hydrogel and aligned at the surface of the core thread. An up-regulation of tendon-related genes (scleraxis and tenascin C) and genes involved in matrix remodelling (matrix metalloproteinases 1, matrix metalloproteinases 2) was observed. Cells were able to produce a collagen-rich matrix, remodelling their micro-environment, which is structurally comparable to native tendon tissue. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Post-tensioning tendon force loss detection using low power pulsed eddy current measurement

    NASA Astrophysics Data System (ADS)

    Kim, Ji-Min; Lee, Jun; Sohn, Hoon

    2018-04-01

    In the field of bridge engineering, pre-fabrication of a bridge member and its construction in site have been issued and studied, which achieves improved quality and rapid construction. For integration of those pre-fabricated segments into a structural member (i.e., a concrete slab, girder and pier), post-tensioning (PT) technique is adopted utilizing a high-strength steel tendon, and an effective investigation of the remaining PT tendon force is essential to assure an overall structural integrity. This study proposes a pulsed eddy current based tendon force loss detection system. A compact eddy current sensor is designed to be installed on the surface of an anchor holding a steel PT tendon. The intensity of the induced eddy current varies with PT tendon force alteration due to the magnetostriction effect of a ferromagnetic material. The advantages of the proposed system are as follows: (1) low power consumption, (2) rapid inspection, and (3) simple installation. Its performance was validated experimentally in a full-scale lab test of a 3.3-m long, 15.2-mm diameter mono-tendon that was tensioned using a universal testing machine. Tendon force was controlled from 20 to 180 kN with 20 kN interval, and eddy current responses were measured and analyzed at each force condition. The proposed damage index and the amount of force loss of PT tendon were monotonically related, and an excessive loss as much as 30 % of an initially-introduced tendon force was successfully predicted.

  20. Measuring Regional Changes in Damaged Tendon

    NASA Astrophysics Data System (ADS)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  1. [Homeostasis and Disorder of Musculoskeletal System.Enthesis formation and repair:Current understanding and perspectives for the future regenerative therapy.

    PubMed

    Tokunaga, Takuya; Arimura, Hitoshi; Mizuta, Hiroshi; Hiraki, Yuji; Shukunami, Chisa

    Tendons and ligaments are dense fibrous connective tissues mainly composed of type I collagen, aligned in highly ordered arrays along the axis of the tendon and ligament. The enthesis is defined as the attachment site of a tendon, ligament, joint capsule, or fascia to bone. During morphogenesis, the cell population co-expressing Scleraxis(Scx)and the SRY-box containing gene 9(Sox9)contributes to the formation of fibrocartilaginous entheses. Scx regulates tendon and ligament maturation, while Sox9 is a key regulatory factor for cartilage formation. The considerable mechanical forces transmitted through the enthesis and avascular properties of the tissue make it more prone to injuries and degenerative changes. Thus, integration of tendons or ligaments with bone following surgical repair remains a clinical challenge. In this review, we summarize the current knowledge regarding the formation, maintenance, damage, and repair of fibrocartilaginous entheses, focusing on the rotator cuff tendon-to-bone attachment sites.

  2. Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.

    PubMed

    Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo

    2018-06-01

    No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.

  3. Arthroscopic suture retrievers and shuttles: a biomechanical investigation of the force required for tendon penetration and defect size.

    PubMed

    Lenz, Christopher G; Wieser, Karl; Lajtai, Georg; Meyer, Dominik C

    2015-11-17

    To compare instruments designed for arthroscopic suture handling during arthroscopic rotator cuff repair, to assess the force needed to penetrate the tendon, and to evaluate the residual defect size. Twenty-one instruments were each tested ten times on thawed sheep infraspinatus tendons. The force needed to pierce the tendon with each instrument was measured using a custom setup. Bone wax plates were used to make the perforation marks visible and to quantify the lesions each instrument created. The force to pierce a tendon had a range of 5.6-18.5 N/mm. Within the group of suture retrievers, the angled instruments required in average 85 % higher forces than straight instruments. The lesion area had a range of 2-7 mm(2). Suture retrievers produced significantly larger lesion sizes compared with suture shuttles. For the identical task of passing a suture through a tendon, differences exist regarding the ease of tendon penetration and potential damage to the tendon for different tools. The design, function, and resulting lesion size may be relevant and important for surgical handling and to avoid excess structural damage to the tendon. These results suggest that choosing the most appropriate tools for arthroscopic suture stitching influences the ease of handling and final integrity of the tissue.

  4. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading.

    PubMed

    Herod, Tyler W; Chambers, Neil C; Veres, Samuel P

    2016-09-15

    In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Non-destructive testing (NDT) of a segmental concrete bridge scheduled for demolition, with a focus on condition assessment and corrosion detection of internal tendons : [summary].

    DOT National Transportation Integrated Search

    2017-06-01

    In this project, Florida International University researchers used segments from a demolished concrete segmental bridge with internal tendons to study damage to post-stressed tendons and to test the effectiveness of various methods of non-destructive...

  6. Engineering tendon and ligament tissues: present developments towards successful clinical products.

    PubMed

    Rodrigues, Márcia T; Reis, Rui L; Gomes, Manuela E

    2013-09-01

    Musculoskeletal diseases are one of the leading causes of disability worldwide. Among them, tendon and ligament injuries represent an important aspect to consider in both athletes and active working people. Tendon and ligament damage is an important cause of joint instability, and progresses into early onset of osteoarthritis, pain, disability and eventually the need for joint replacement surgery. The social and economical burden associated with these medical conditions presents a compelling argument for greater understanding and expanding research on this issue. The particular physiology of tendons and ligaments (avascular, hypocellular and overall structural mechanical features) makes it difficult for currently available treatments to reach a complete and long-term functional repair of the damaged tissue, especially when complete tear occurs. Despite the effort, the treatment modalities for tendon and ligament are suboptimal, which have led to the development of alternative therapies, such as the delivery of growth factors, development of engineered scaffolds or the application of stem cells, which have been approached in this review. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    PubMed

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  8. Returning to Overuse Activity Following a Supraspinatus and Infraspinatus Tear Leads to Joint Damage in a Rat Model

    PubMed Central

    Reuther, Katherine E.; Thomas, Stephen J.; Evans, Elisabeth F.; Tucker, Jennica J.; Sarver, Joseph J.; Ilkhani-Pour, Sarah; Gray, Chancellor F.; Voleti, Pramod; Glaser, David L.; Soslowsky, Louis J.

    2013-01-01

    Large rotator cuff tears (supraspinatus and infraspinatus) are common in patients that perform overhead activities (laborers, athletes). In addition, following large cuff tears, these patients commonly attempt to return to pre-injury activity levels. However, there is a limited understanding of the damaging effects on the uninjured joint tissues when doing so. Therefore, the objective of this study was to investigate the effect of returning to overuse activity following a supraspinatus and infraspinatus tear on shoulder function and the structural and biological properties of the intact tendons and glenoid cartilage. Forty rats underwent four weeks of overuse followed by detachment of the supraspinatus and infraspinatus tendons and were then randomized into two groups: return to overuse or cage activity. Ambulatory measurements were performed over time and structural and biologic properties of the adjacent tendons and cartilage were evaluated. Results demonstrated that animals returning to overuse activity did not have altered shoulder function but despite this, did have altered cartilage and tendon properties. These mechanical changes corresponded to altered transcriptional regulation of chondrogenic genes within cartilage and tendon. This study helps define the mechanical and biologic mechanisms leading to joint damage and provides a framework for treating active cuff tear patients. PMID:23764174

  9. Muscle force loss and soreness subsequent to maximal eccentric contractions depend on the amount of fascicle strain in vivo.

    PubMed

    Guilhem, G; Doguet, V; Hauraix, H; Lacourpaille, L; Jubeau, M; Nordez, A; Dorel, S

    2016-06-01

    Defining the origins of muscle injury has important rehabilitation and exercise applications. However, current knowledge of muscle damage mechanics in human remains unclear in vivo. This study aimed to determine the relationships between muscle-tendon unit mechanics during maximal eccentric contractions and the extent of subsequent functional impairments induced by muscle damage. The length of the muscle-tendon unit, fascicles and tendinous tissues was continuously measured on the gastrocnemius medialis using ultrasonography, in time with torque, during 10 sets of 30 maximal eccentric contractions of plantar flexors at 45°s(-1) , in seventeen participants. Muscle-tendon unit, fascicles and tendinous tissues were stretched up to 4.44 ± 0.33 cm, 2.31 ± 0.64 cm and 1.92 ± 0.61 cm respectively. Fascicle stretch length, lengthening amplitude and negative fascicle work beyond slack length were significantly correlated with the force decrease 48 h post-exercise (r = 0.51, 0.47 and 0.68, respectively; P < 0.05). This study demonstrates that the strain applied to human muscle fibres during eccentric contractions strongly influences the magnitude of muscle damage in vivo. Achilles tendon compliance decreases the amount of strain, while architectural gear ratio may moderately contribute to attenuating muscle fascicle lengthening and hence muscle damage. Further studies are necessary to explore the impact of various types of task to fully understand the contribution of muscle-tendon interactions during active lengthening to muscle damage. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  10. Biologics for tendon repair☆

    PubMed Central

    Docheva, Denitsa; Müller, Sebastian A.; Majewski, Martin; Evans, Christopher H.

    2015-01-01

    Tendon injuries are common and present a clinical challenge to orthopedic surgery mainly because these injuries often respond poorly to treatment and require prolonged rehabilitation. Therapeutic options used to repair ruptured tendons have consisted of suture, autografts, allografts, and synthetic prostheses. To date, none of these alternatives has provided a successful long-term solution, and often the restored tendons do not recover their complete strength and functionality. Unfortunately, our understanding of tendon biology lags far behind that of other musculoskeletal tissues, thus impeding the development of new treatment options for tendon conditions. Hence, in this review, after introducing the clinical significance of tendon diseases and the present understanding of tendon biology, we describe and critically assess the current strategies for enhancing tendon repair by biological means. These consist mainly of applying growth factors, stem cells, natural biomaterials and genes, alone or in combination, to the site of tendon damage. A deeper understanding of how tendon tissue and cells operate, combined with practical applications of modern molecular and cellular tools could provide the long awaited breakthrough in designing effective tendon-specific therapeutics and overall improvement of tendon disease management. PMID:25446135

  11. MicroRNA29a regulates IL-33-mediated tissue remodelling in tendon disease

    PubMed Central

    Millar, Neal L.; Gilchrist, Derek S.; Akbar, Moeed; Reilly, James H.; Kerr, Shauna C.; Campbell, Abigail L.; Murrell, George A. C.; Liew, Foo Y.; Kurowska-Stolarska, Mariola; McInnes, Iain B.

    2015-01-01

    MicroRNA (miRNA) has the potential for cross-regulation and functional integration of discrete biological processes during complex physiological events. Utilizing the common human condition tendinopathy as a model system to explore the cross-regulation of immediate inflammation and matrix synthesis by miRNA we observed that elevated IL-33 expression is a characteristic of early tendinopathy. Using in vitro tenocyte cultures and in vivo models of tendon damage, we demonstrate that such IL-33 expression plays a pivotal role in the transition from type 1 to type 3 collagen (Col3) synthesis and thus early tendon remodelling. Both IL-33 effector function, via its decoy receptor sST2, and Col3 synthesis are regulated by miRNA29a. Downregulation of miRNA29a in human tenocytes is sufficient to induce an increase in Col3 expression. These data provide a molecular mechanism of miRNA-mediated integration of the early pathophysiologic events that facilitate tissue remodelling in human tendon after injury. PMID:25857925

  12. The mechanobiological aetiopathogenesis of tendinopathy: is it the over-stimulation or the under-stimulation of tendon cells?

    PubMed Central

    Arnoczky, Steven P; Lavagnino, Michael; Egerbacher, Monika

    2007-01-01

    While there is a significant amount of information available on the clinical presentation(s) and pathological changes associated with tendinopathy, the precise aetiopathogenesis of this condition remains a topic of debate. Classically, the aetiology of tendinopathy has been linked to the performance of repetitive activities (so-called overuse injuries). This has led many investigators to suggest that it is the mechanobiologic over-stimulation of tendon cells that is the initial stimulus for the degradative processes which have been shown to accompany tendinopathy. Although several studies have been able to demonstrate that the in vitro over-stimulation of tendon cells in monolayer can result in a pattern(s) of gene expression seen in clinical cases of tendinopathy, the strain magnitudes and durations used in these in vitro studies, as well as the model systems, may not be clinically relevant. Using a rat tail tendon model, we have studied the in vitro mechanobiologic response of tendon cells in situ to various tensile loading regimes. These studies have led to the hypothesis that the aetiopathogenic stimulus for the degenerative cascade which precedes the overt pathologic development of tendinopathy is the catabolic response of tendon cells to mechanobiologic under-stimulation as a result of microscopic damage to the collagen fibres of the tendon. In this review, we examine the rationale for this hypothesis and provide evidence in support of this theory. PMID:17696902

  13. Shoulder pain

    MedlinePlus

    Pain - shoulder ... changes around the rotator cuff can cause shoulder pain. You may have pain when lifting the arm above your head or ... The most common cause of shoulder pain occurs when rotator cuff tendons ... The tendons become inflamed or damaged. This condition ...

  14. Specialization of tendon mechanical properties results from interfascicular differences

    PubMed Central

    Thorpe, Chavaunne T.; Udeze, Chineye P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2012-01-01

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage. PMID:22764132

  15. Specialization of tendon mechanical properties results from interfascicular differences.

    PubMed

    Thorpe, Chavaunne T; Udeze, Chineye P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2012-11-07

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage.

  16. Effect of Return to Overuse Activity Following an Isolated Supraspinatus Tendon Tear on Adjacent Intact Tendons and Glenoid Cartilage in a Rat Model

    PubMed Central

    Reuther, Katherine E.; Thomas, Stephen J.; Sarver, Joseph J.; Tucker, Jennica J.; Lee, Chang-Soo; Gray, Chancellor F.; Glaser, David L.; Soslowsky, Louis J.

    2013-01-01

    Rotator cuff tears are common conditions that can alter shoulder mechanics and may lead to damage of intact joint tissues. These injuries are of particular concern in populations who perform tasks requiring repetitive overhead activity (e.g., athletes and laborers) and who are likely to return to aggressive pre-injury activity levels despite limited understanding of the potentially damaging effects on the remaining tissues. Therefore, we investigated the effect of returning to overuse activity following a supraspinatus tear on shoulder function and the mechanical properties of the remaining intact tendons and glenoid cartilage. Forty rats underwent 4 weeks of overuse activity to create a tendinopathic condition followed by detachment of the supraspinatus tendon and were then randomized into two groups: continued overuse or cage activity. Ambulatory measurements were performed throughout the 8 weeks prior to euthaniasia, and properties of the adjacent tendons and cartilage were evaluated. Results demonstrated that shoulder function was not compromised in the return to overuse group. However, alterations of the glenoid cartilage and biceps tendon properties occurred. Our results help define the contributory roles of common mechanical injury mechanisms and provide a framework by which physicians could better prescribe long-term treatment strategies for patients. PMID:23280495

  17. Effect of return to overuse activity following an isolated supraspinatus tendon tear on adjacent intact tendons and glenoid cartilage in a rat model.

    PubMed

    Reuther, Katherine E; Thomas, Stephen J; Sarver, Joseph J; Tucker, Jennica J; Lee, Chang-Soo; Gray, Chancellor F; Glaser, David L; Soslowsky, Louis J

    2013-05-01

    Rotator cuff tears are common conditions that can alter shoulder mechanics and may lead to damage of intact joint tissues. These injuries are of particular concern in populations who perform tasks requiring repetitive overhead activity (e.g., athletes and laborers) and who are likely to return to aggressive pre-injury activity levels despite limited understanding of the potentially damaging effects on the remaining tissues. Therefore, we investigated the effect of returning to overuse activity following a supraspinatus tear on shoulder function and the mechanical properties of the remaining intact tendons and glenoid cartilage. Forty rats underwent 4 weeks of overuse activity to create a tendinopathic condition followed by detachment of the supraspinatus tendon and were then randomized into two groups: continued overuse or cage activity. Ambulatory measurements were performed throughout the 8 weeks prior to euthaniasia, and properties of the adjacent tendons and cartilage were evaluated. Results demonstrated that shoulder function was not compromised in the return to overuse group. However, alterations of the glenoid cartilage and biceps tendon properties occurred. Our results help define the contributory roles of common mechanical injury mechanisms and provide a framework by which physicians could better prescribe long-term treatment strategies for patients. Copyright © 2012 Orthopaedic Research Society.

  18. Changes in Indirect Markers of Muscle Damage and Tendons After Daily Drop Jumping Exercise with Rapid Load Increase

    PubMed Central

    Paleckis, Vidas; Mickevičius, Mantas; Snieckus, Audrius; Streckis, Vytautas; Pääsuke, Mati; Rutkauskas, Saulius; Steponavičiūtė, Rasa; Skurvydas, Albertas; Kamandulis, Sigitas

    2015-01-01

    The aim of this study was to assess changes in indirect markers of muscle damage and type I collagen degradation, as well as, patellar and Achilles tendon morphological differences during nine daily drop-jumps sessions with constant load alternated with rapid increases in load to test the hypothesis that frequent drop-jump training results in negative muscular and tendon adaptation. Young men (n = 9) performed daily drop jump workouts with progression every 3 days in terms of number of jumps, platform height and squat amplitude. Voluntary and electrically evoked knee extensor torque, muscle soreness, blood plasma creatine kinase (CK) activity and carboxyterminal cross-linked telopeptide (ICTP), patellar and Achilles tendon thickness and cross-sectional area (CSA) were assessed at different time points during the training period and again on days 1, 3, 10 and 17 after the training. The findings were as follows: (1) steady decline in maximal muscle strength with major recovery within 24 hours after the first six daily training sessions; (2) larger decline in electrically induced muscle torque and prolonged recovery during last three training sessions; (3) increase in patellar and Achilles tendons CSA without change in thickness towards the end of training period; (4) increase in jump height but not in muscle strength after whole training period. Our findings suggest that frequent drop-jump sessions with constant load alternated with rapid increases in load do not induce severe muscle damage or major changes in tendons, nonetheless, this type of loading is not advisable for muscle strength improvement. Key points Frequent drop jump training induces activation mode dependent muscle torque depression late in the training period. No significant changes in the thickness of patellar and Achilles tendons are observed during frequent training, while CSA increases towards the end of training period. Longitudinal effect for jump height but not for muscle strength is evident after the whole training period. PMID:26664280

  19. Muscle Damage following Maximal Eccentric Knee Extensions in Males and Females

    PubMed Central

    2016-01-01

    Aim To investigate whether there is a sex difference in exercise induced muscle damage. Materials and Method Vastus Lateralis and patella tendon properties were measured in males and females using ultrasonography. During maximal voluntary eccentric knee extensions (12 reps x 6 sets), Vastus Lateralis fascicle lengthening and maximal voluntary eccentric knee extensions torque were recorded every 10° of knee joint angle (20–90°). Isometric torque, Creatine Kinase and muscle soreness were measured pre, post, 48, 96 and 168 hours post damage as markers of exercise induced muscle damage. Results Patella tendon stiffness and Vastus Lateralis fascicle lengthening were significantly higher in males compared to females (p<0.05). There was no sex difference in isometric torque loss and muscle soreness post exercise induced muscle damage (p>0.05). Creatine Kinase levels post exercise induced muscle damage were higher in males compared to females (p<0.05), and remained higher when maximal voluntary eccentric knee extension torque, relative to estimated quadriceps anatomical cross sectional area, was taken as a covariate (p<0.05). Conclusion Based on isometric torque loss, there is no sex difference in exercise induced muscle damage. The higher Creatine Kinase in males could not be explained by differences in maximal voluntary eccentric knee extension torque, Vastus Lateralis fascicle lengthening and patella tendon stiffness. Further research is required to understand the significant sex differences in Creatine Kinase levels following exercise induced muscle damage. PMID:26986066

  20. A review on animal models and treatments for the reconstruction of Achilles and flexor tendons.

    PubMed

    Bottagisio, Marta; Lovati, Arianna B

    2017-03-01

    Tendon is a connective tissue mainly composed of collagen fibers with peculiar mechanical properties essential to functional movements. The increasing incidence of tendon traumatic injuries and ruptures-associated or not with the loss of tissue-falls on the growing interest in the field of tissue engineering and regenerative medicine. The use of animal models is mandatory to deepen the knowledge of the tendon healing response to severe damages or acute transections. Thus, the selection of preclinical models is crucial to ensure a successful translation of effective and safe innovative treatments to the clinical practice. The current review is focused on animal models of tendon ruptures and lacerations or defective injuries with large tissue loss that require surgical approaches or grafting procedures. Data published between 2000 and 2016 were examined. The analyzed articles were compiled from Pub Med-NCBI using search terms, including animal model(s) AND tendon augmentation OR tendon substitute(s) OR tendon substitution OR tendon replacement OR tendon graft(s) OR tendon defect(s) OR tendon rupture(s). This article presents the existing preclinical models - considering their advantages and disadvantages-in which translational progresses have been made by using bioactive sutures or tissue engineering that combines biomaterials with cells and growth factors to efficiently treat transections or large defects of Achilles and flexor tendons.

  1. Indicators of replicative damage in equine tendon fibroblast monolayers

    PubMed Central

    2013-01-01

    Background Superficial digital flexor tendon (SDFT) injuries of horses usually follow cumulative matrix microdamage; it is not known why the reparative abilities of tendon fibroblasts are overwhelmed or subverted. Relevant in vitro studies of this process require fibroblasts not already responding to stresses caused by the cell culture protocols. We investigated indicators of replicative damage in SDFT fibroblast monolayers, effects of this on their reparative ability, and measures that can be taken to reduce it. Results We found significant evidence of replicative stress, initially observing consistently large numbers of binucleate (BN) cells. A more variable but prominent feature was the presence of numerous gammaH2AX (γH2AX) puncta in nuclei, this being a histone protein that is phosphorylated in response to DNA double-stranded breaks (DSBs). Enrichment for injury detection and cell cycle arrest factors (p53 (ser15) and p21) occurred most frequently in BN cells; however, their numbers did not correlate with DNA damage levels and it is likely that the two processes have different causative mechanisms. Such remarkable levels of injury and binucleation are usually associated with irradiation, or treatment with cytoskeletal-disrupting agents. Both DSBs and BN cells were greatest in subconfluent (replicating) monolayers. The DNA-damaged cells co-expressed the replication markers TPX2/repp86 and centromere protein F. Once damaged in the early stages of culture establishment, fibroblasts continued to express DNA breaks with each replicative cycle. However, significant levels of cell death were not measured, suggesting that DNA repair was occurring. Comet assays showed that DNA repair was delayed in proportion to levels of genotoxic stress. Conclusions Researchers using tendon fibroblast monolayers should assess their “health” using γH2AX labelling. Continued use of early passage cultures expressing initially high levels of γH2AX puncta should be avoided for mechanistic studies and ex-vivo therapeutic applications, as this will not be resolved with further replicative cycling. Low density cell culture should be avoided as it enriches for both DNA damage and mitotic defects (polyploidy). As monolayers differing only slightly in baseline DNA damage levels showed markedly variable responses to a further injury, studies of effects of various stressors on tendon cells must be very carefully controlled. PMID:24025445

  2. Shear load transfer in high and low stress tendons.

    PubMed

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2015-05-01

    Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Shear Load Transfer in High and Low Stress Tendons

    PubMed Central

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2016-01-01

    Background Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructure (helical versus linear) may redistribute loads differently. Method of Approach This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20-60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Results and Conclusions Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. PMID:25700261

  4. THE ROLE OF MECHANOBIOLOGY IN TENDON HEALING

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo; Galatz, Leesa M.; Thomopoulos, Stavros

    2011-01-01

    Mechanical cues affect tendon healing, homeostasis, and development in a variety of settings. Alterations in the mechanical environment are known to result in changes in the expression of extracellular matrix proteins, growth factors, transcription factors, and cytokines that can alter tendon structure and cell viability. Loss of muscle force in utero or in the immediate postnatal period delays tendon and enthesis development. The response of healing tendons to mechanical load varies depending on anatomic location. Flexor tendons require motion to prevent adhesion formation, yet excessive force results in gap formation and subsequent weakening of the repair. Excessive motion in the setting of anterior cruciate ligament reconstruction causes accumulation of macrophages, which are detrimental to tendon graft healing. Complete removal of load is detrimental to rotator cuff healing, yet large forces are also harmful. Controlled loading can enhance healing in most settings; however, a fine balance must be reached between loads that are too low (leading to a catabolic state) and too high (leading to micro-damage). This review will summarize existing knowledge of the mechanobiology of tendon development, homeostasis, and healing. PMID:22244066

  5. [Application of silk-based tissue engineering scaffold for tendon / ligament regeneration].

    PubMed

    Hu, Yejun; Le, Huihui; Jin, Zhangchu; Chen, Xiao; Yin, Zi; Shen, Weiliang; Ouyang, Hongwei

    2016-03-01

    Tendon/ligament injury is one of the most common impairments in sports medicine. The traditional treatments of damaged tissue repair are unsatisfactory, especially for athletes, due to lack of donor and immune rejection. The strategy of tissue engineering may break through these limitations, and bring new hopes to tendon/ligament repair, even regeneration. Silk is a kind of natural biomaterials, which has good biocompatibility, wide range of mechanical properties and tunable physical structures; so it could be applied as tendon/ligament tissue engineering scaffolds. The silk-based scaffold has robust mechanical properties; combined with other biological ingredients, it could increase the surface area, promote more cell adhesion and improve the biocompatibility. The potential clinical application of silk-based scaffold has been confirmed by in vivo studies on tendon/ligament repairing, such as anterior cruciate ligament, medial collateral ligament, achilles tendon and rotator cuff. To develop novel biomechanically stable and host integrated tissue engineered tendon/ligament needs more further micro and macro studies, combined with product development and clinical application, which will give new hope to patients with tendon/ligament injury.

  6. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading

    PubMed Central

    Thorpe, Chavaunne T.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2014-01-01

    Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy. PMID:24402919

  7. Articulated Bone Block for Posterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft: Surgical Technique to Facilitate Graft Passage.

    PubMed

    Cugat, Ramón; Alentorn-Geli, Eduard; Cuscó, Xavier; Navarro, Jordi; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Seijas, Roberto; Barastegui, David; García-Balletbó, Montse

    2018-02-01

    Posterior cruciate ligament reconstruction using the transtibial technique provides successful clinical outcomes. However, a bone-patellar tendon-bone (BTB) autograft with the transtibial technique has not been used by some surgeons because of concerns with graft passage from the tibial to the femoral tunnels (sharp turn) that can damage graft fibers. In the present surgical technique, an arthroscopic, transtibial, single-bundle technique for posterior cruciate ligament reconstruction using the BTB autograft with an easy and effective technical tip to facilitate graft passage is presented. Once the BTB is harvested, the femoral bone block is divided into 2 equal-sized blocks providing an articulated structure while preserving the tendon component. This facilitates the passage of the BTB tendon once it is entered in the posterior tibia and the graft has to make a sharp turn to reach the femoral tunnel. This easy and effective technique tip may avoid graft damage during the sharp turn, while maintaining all the advantages of a BTB autograft (bone-to-bone healing, own tissue with fast incorporation, and strong fixation and stability).

  8. Low-power-laser therapy used in tendon damage

    NASA Astrophysics Data System (ADS)

    Strupinska, Ewa

    1996-03-01

    The following paper covers evaluation of low-power laser therapy results in chronic Achilles tendon damage and external Epicondylalia (tennis elbow). Fifty patients with Achilles damage (18 women and 32 men, age average 30, 24 plus or minus 10, 39 years) and fifty patients having external Epicondyalgiae (31 women and 19 men, age average 44, 36 plus or minus 10, 88 years) have been examined. The patients were irradiated by semiconductor infrared laser wavelength 904 nm separately or together with helium-neon laser wavelength 632.8 nm. The results of therapy have been based on the patient's interviews and examinations of patients as well as on the Laitinen pain questionnaire. The results prove analgesic effects in usage of low- power laser radiation therapy can be obtained.

  9. Coordinated collagen and muscle protein synthesis in human patella tendon and quadriceps muscle after exercise

    PubMed Central

    Miller, Benjamin F; Olesen, Jens L; Hansen, Mette; Døssing, Simon; Crameri, Regina M; Welling, Rasmus J; Langberg, Henning; Flyvbjerg, Allan; Kjaer, Michael; Babraj, John A; Smith, Kenneth; Rennie, Michael J

    2005-01-01

    We hypothesized that an acute bout of strenuous, non-damaging exercise would increase rates of protein synthesis of collagen in tendon and skeletal muscle but these would be less than those of muscle myofibrillar and sarcoplasmic proteins. Two groups (n = 8 and 6) of healthy young men were studied over 72 h after 1 h of one-legged kicking exercise at 67% of maximum workload (Wmax). To label tissue proteins in muscle and tendon primed, constant infusions of [1-13C]leucine or [1-13C]valine and flooding doses of [15N] or [13C]proline were given intravenously, with estimation of labelling in target proteins by gas chromatography–mass spectrometry. Patellar tendon and quadriceps biopsies were taken in exercised and rested legs at 6, 24, 42 or 48 and 72 h after exercise. The fractional synthetic rates of all proteins were elevated at 6 h and rose rapidly to peak at 24 h post exercise (tendon collagen (0.077% h−1), muscle collagen (0.054% h−1), myofibrillar protein (0.121% h−1), and sarcoplasmic protein (0.134% h−1)). The rates decreased toward basal values by 72 h although rates of tendon collagen and myofibrillar protein synthesis remained elevated. There was no tissue damage of muscle visible on histological evaluation. Neither tissue microdialysate nor serum concentrations of IGF-I and IGF binding proteins (IGFBP-3 and IGFBP-4) or procollagen type I N-terminal propeptide changed from resting values. Thus, there is a rapid increase in collagen synthesis after strenuous exercise in human tendon and muscle. The similar time course of changes of protein synthetic rates in different cell types supports the idea of coordinated musculotendinous adaptation. PMID:16002437

  10. Percutaneous Needle Tenotomy for the Treatment of Muscle and Tendon Contractures in Adults With Brain Damage: Results and Complications.

    PubMed

    Coroian, Flavia; Jourdan, Claire; Froger, Jérome; Anquetil, Claire; Choquet, Olivier; Coulet, Bertand; Laffont, Isabelle

    2017-05-01

    To study the results and complications of percutaneous needle tenotomy for superficial retracted tendons in patients with brain damage. Prospective observational study. University hospital. Patients with severe brain damage (N=38; mean age, 60.7y; age range, 24-93y; 21 women) requiring surgical management of contractures and eligible for percutaneous needle tenotomy were enrolled between February 2015 and February 2016. The percutaneous needle tenotomy gesture was performed by a physical medicine and rehabilitation physician trained by an orthopedic surgeon, under local or locoregional anesthesia. Treated tendons varied among patients. All patients were evaluated at 1, 3, and 6 months to assess surgical outcomes (joint range of motion [ROM], pain, and functional improvement) while screening for complications. Improvements in ROM (37/38) and contractures-related pain (12/12) were satisfactory. Functional results were satisfactory (Goal Attainment Scale score ≥0) for most patients (37/38): nursing (n=12), putting shoes on (n=8), getting in bed or sitting on a chair (n=6), verticalization (n=7), transfers and gait (n=8), and grip (n=2). Five patients had complications related to the surgical gesture: cast-related complications (n=2), hand hematoma (n=2), and cutaneous necrosis of the Achilles tendon in a patient with previous obliterative arteriopathy of the lower limbs (n=1). Percutaneous needle tenotomy yields good results in the management of selected superficial muscle and tendon contractures. The complications rate is very low, and this treatment can be an alternative to conventional surgery in frail patients with neurologic diseases. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Application of biomechanics to tendon transfers.

    PubMed

    Hoard, A S; Bell-Krotoski, J A; Mathews, R

    1995-01-01

    This article has focused on considerations important in the application of biomechanics to tendon transfers and has used an example protocol. Different surgeries require different protocols. What is most important is that specific protocols are used, and that they are both safe and effective. The communication among the therapist, surgeon, and patient is essential with the use of any protocol. As Brand has stated, "A hand is a very personal thing. It is the interface between the patient and his or her world. It is an emblem of strength, beauty, skill, sexuality, and sensibility. When it is damaged it becomes a symbol of the vulnerability of the whole person." For the patient who has damage from nerve palsy, paralysis, or injury resulting in a dysfunctional hand, a tendon transfer procedure may prove to be a viable option to restore balance and function, especially if the biomechanics of deformity and correction are considered.

  12. Evaluating Changes in Tendon Crimp with Fatigue Loading as an ex vivo Structural Assessment of Tendon Damage

    PubMed Central

    Freedman, Benjamin R.; Zuskov, Andrey; Sarver, Joseph J.; Buckley, Mark R.; Soslowsky, Louis J.

    2015-01-01

    The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanics, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure. PMID:25773654

  13. [Rupture of the tendon of the tibialis anterior muscle : Etiology, clinical symptoms and treatment].

    PubMed

    Waizy, H; Bouillon, B; Stukenborg-Colsman, C; Yao, D; Ettinger, S; Claassen, L; Plaass, C; Danniilidis, K; Arbab, D

    2017-12-01

    Ruptures of the tendon of the tibialis anterior muscle tend to occur in the context of degenerative impairments. This mainly affects the distal avascular portion of the tendon. Owing to the good compensation through the extensor hallucis longus and extensor digitorum muscles, diagnosis is often delayed. In addition to the clinical examination, magnetic resonance inaging (MRI) diagnostics are of particular importance, although damage or rupture of the tendon can also be demonstrated sonographically. Therapeutic measures include conservative or operative measures, depending on the clinical symptoms. Conservative stabilization of the ankle can be achieved by avoiding plantar flexion using a peroneal orthosis or an ankle-foot orthosis. Subsequent problems, such as metatarsalgia or overloading of the medial foot edge can be addressed by insoles or a corresponding shoe adjustment. An operative procedure is indicated when there is corresponding suffering due to pressure and functional impairment. The direct end-to-end reconstruction of the tendon is only rarely possible in cases of delayed diagnosis due to the degenerative situation and the retraction of the tendon stumps. Depending on the defect size and the tendon quality, various operative techniques, such as rotationplasty, free transplants or tendon transfer can be used.

  14. Viscoelastic shear lag model to predict the micromechanical behavior of tendon under dynamic tensile loading.

    PubMed

    Wu, Jiayu; Yuan, Hong; Li, Longyuan; Fan, Kunjie; Qian, Shanguang; Li, Bing

    2018-01-21

    Owing to its viscoelastic nature, tendon exhibits stress rate-dependent breaking and stiffness function. A Kelvin-Voigt viscoelastic shear lag model is proposed to illustrate the micromechanical behavior of the tendon under dynamic tensile conditions. Theoretical closed-form expressions are derived to predict the deformation and stress transfer between fibrils and interfibrillar matrix while tendon is dynamically stretched. The results from the analytical solutions demonstrate that how the fibril overlap length and fibril volume fraction affect the stress transfer and mechanical properties of tendon. We find that the viscoelastic property of interfibrillar matrix mainly results in collagen fibril failure under fast loading rate or creep rupture of tendon. However, discontinuous fibril model and hierarchical structure of tendon ensure relative sliding under slow loading rate, helping dissipate energy and protecting fibril from damage, which may be a key reason why regularly staggering alignment microstructure is widely selected in nature. According to the growth, injury, healing and healed process of tendon observed by many researchers, the conclusions presented in this paper agrees well with the experimental findings. Additionally, the emphasis of this paper is on micromechanical behavior of tendon, whereas this analytical viscoelastic shear lag model can be equally applicable to other soft or hard tissues, owning the similar microstructure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Development of a reinforced electrochemically aligned collagen bioscaffold for tendon tissue engineering applications

    NASA Astrophysics Data System (ADS)

    Uquillas Paredes, Jorge Alfredo

    Type-I collagen is a promising biomaterial that can be used to synthesize bioscaffolds as a strategy to regenerate and repair damaged tendons. The existing in vitro prepared collagen bioscaffolds are in the form of gels, foams, or extruded fibers. These bioscaffolds readily present sites for attachment of biological factors and cells; however, they have extremely poor biomechanical properties in comparison to the properties of native tendons. The biomechanical function of type-I collagen bioscaffolds needs to be elevated to the level of natural tissues for this biomaterial to replace mechanically challenged tendons in a functionally meaningful way. The overall goal of this dissertation is to develop a reinforced electrochemically aligned collagenous bioscaffold for applications in tendon tissue engineering. The bioscaffold is synthesized by a unique electrochemical process via isoelectric focusing (IEF) to attain a very high degree of molecular alignment and packing density. This dissertation presents progress made on four aims: A) development of simple and descriptive electrochemical theory via the mathematical model of IEF and the forces acting on collagen alignment under an electric field; B) optimization of the post-alignment PBS treatment step to achieve d- banding pattern in uncrosslinked electrochemically aligned collagen (ELAC) bioscaffolds; C) optimization of the best crosslinking protocol to produce the strongest possible ELAC biomaterial with excellent cellular compatibility; and D) in vivo evaluation of the biocompatibility and biodegradability properties of electronically aligned collagen bioscaffolds. The results of this dissertation provide strong evidence showing that reinforced ELAC bioscaffolds could be used clinically in the future to repair damaged tendons.

  16. Rat supraspinatus muscle atrophy after tendon detachment.

    PubMed

    Barton, Elisabeth R; Gimbel, Jonathan A; Williams, Gerald R; Soslowsky, Louis J

    2005-03-01

    Rotator cuff tears are one of the most common tendon disorders found in the healthy population. Tendon tears not only affect the biomechanical properties of the tendon, but can also lead to debilitation of the muscles attached to the damaged tendons. The changes that occur in the muscle after tendon detachment are not well understood. A rat rotator cuff model was utilized to determine the time course of changes that occur in the supraspinatus muscle after tendon detachment. It was hypothesized that the lack of load on the supraspinatus muscle would cause a significant decrease in muscle mass and a conversion of muscle fiber properties toward those of fast fiber types. Tendons were detached at the insertion on the humerus without repair. Muscle mass, morphology and fiber properties were measured at one, two, four, eight, and 16 weeks after detachment. Tendon detachment resulted in a rapid loss of muscle mass, an increase in the proportion of fast muscle fibers, and an increase in the fibrotic content of the muscle bed, concomitant with the appearance of adhesions of the tendon to surrounding surfaces. At 16 weeks post-detachment, muscle mass and the fiber properties in the deep muscle layers returned to normal levels. However, the fiber shifts observed in the superficial layers persisted throughout the experiment. These results suggest that load returned to the muscle via adhesions to surrounding surfaces, which may be sufficient to reverse changes in muscle mass.

  17. How tendons buffer energy dissipation by muscle

    PubMed Central

    Roberts, Thomas J.; Konow, Nicolai

    2013-01-01

    To decelerate the body and limbs, muscles actively lengthen to dissipate energy. During rapid energy-dissipating events, tendons buffer the work done on muscle by temporarily storing elastic energy, then releasing this energy to do work on the muscle. This elastic mechanism may reduce the risk of muscle damage by reducing peak forces and lengthening rates of active muscle. PMID:23873133

  18. Matrix metabolism rate differs in functionally distinct tendons.

    PubMed

    Birch, Helen L; Worboys, Sarah; Eissa, Sabry; Jackson, Brendan; Strassburg, Sandra; Clegg, Peter D

    2008-04-01

    Tendon matrix integrity is vital to ensure adequate mechanical properties for efficient function. Although historically tendon was considered to be relatively inert, recent studies have shown that tendon matrix turnover is active. During normal physiological activities some tendons are subjected to stress and strains much closer to their failure properties than others. Tendons with low safety margins are those which function as energy stores such as the equine superficial digital flexor tendon (SDFT) and human Achilles tendon (AT). We postulate therefore that energy storing tendons suffer a higher degree of micro-damage and thus have a higher rate of matrix turnover than positional tendons. The hypothesis was tested using tissue from the equine SDFT and common digital extensor tendon (CDET). Matrix turnover was assessed indirectly by a combination of measurements for matrix age, markers of degradation, potential for degradation and protein expression. Results show that despite higher cellularity, the SDFT has lower relative levels of mRNA for collagen types I and III. Non-collagenous proteins, although expressed at different levels per cell, do not appear to differ between tendon types. Relative levels of mRNA for MMP1, MMP13 and both pro-MMP3 and MMP13 protein activity were significantly higher in the CDET. Correspondingly levels of cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were higher in the CDET and tissue fluorescence lower suggesting more rapid turnover of the collagenous component. Reduced or inhibited collagen turnover in the SDFT may account for the high level of degeneration and subsequent injury compared to the CDET.

  19. HGF Mediates the Anti-inflammatory Effects of PRP on Injured Tendons

    PubMed Central

    Zhang, Jianying; Middleton, Kellie K.; Fu, Freddie H.; Im, Hee-Jeong; Wang, James H-C.

    2013-01-01

    Platelet-rich plasma (PRP) containing hepatocyte growth factor (HGF) and other growth factors are widely used in orthopaedic/sports medicine to repair injured tendons. While PRP treatment is reported to decrease pain in patients with tendon injury, the mechanism of this effect is not clear. Tendon pain is often associated with tendon inflammation, and HGF is known to protect tissues from inflammatory damages. Therefore, we hypothesized that HGF in PRP causes the anti-inflammatory effects. To test this hypothesis, we performed in vitro experiments on rabbit tendon cells and in vivo experiments on a mouse Achilles tendon injury model. We found that addition of PRP or HGF decreased gene expression of COX-1, COX-2, and mPGES-1, induced by the treatment of tendon cells in vitro with IL-1β. Further, the treatment of tendon cell cultures with HGF antibodies reduced the suppressive effects of PRP or HGF on IL-1β-induced COX-1, COX-2, and mPGES-1 gene expressions. Treatment with PRP or HGF almost completely blocked the cellular production of PGE2 and the expression of COX proteins. Finally, injection of PRP or HGF into wounded mouse Achilles tendons in vivo decreased PGE2 production in the tendinous tissues. Injection of platelet-poor plasma (PPP) however, did not reduce PGE2 levels in the wounded tendons, but the injection of HGF antibody inhibited the effects of PRP and HGF. Further, injection of PRP or HGF also decreased COX-1 and COX-2 proteins. These results indicate that PRP exerts anti-inflammatory effects on injured tendons through HGF. This study provides basic scientific evidence to support the use of PRP to treat injured tendons because PRP can reduce inflammation and thereby reduce the associated pain caused by high levels of PGE2. PMID:23840657

  20. Tendon material properties vary and are interdependent among turkey hindlimb muscles

    PubMed Central

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P.; Roberts, Thomas J.

    2012-01-01

    SUMMARY The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress–strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r2=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity. PMID:22771746

  1. Tendon material properties vary and are interdependent among turkey hindlimb muscles.

    PubMed

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P; Roberts, Thomas J

    2012-10-15

    The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress-strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r(2)=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity.

  2. Basic FGF or VEGF gene therapy corrects insufficiency in the intrinsic healing capacity of tendons

    PubMed Central

    Tang, Jin Bo; Wu, Ya Fang; Cao, Yi; Chen, Chuan Hao; Zhou, You Lang; Avanessian, Bella; Shimada, Masaru; Wang, Xiao Tian; Liu, Paul Y.

    2016-01-01

    Tendon injury during limb motion is common. Damaged tendons heal poorly and frequently undergo unpredictable ruptures or impaired motion due to insufficient innate healing capacity. By basic fibroblast growth factor (bFGF) or vascular endothelial growth factor (VEGF) gene therapy via adeno-associated viral type-2 (AAV2) vector to produce supernormal amount of bFGF or VEGF intrinsically in the tendon, we effectively corrected the insufficiency of the tendon healing capacity. This therapeutic approach (1) resulted in substantial amelioration of the low growth factor activity with significant increases in bFGF or VEGF from weeks 4 to 6 in the treated tendons (p < 0.05 or p < 0.01), (2) significantly promoted production of type I collagen and other extracellular molecules (p < 0.01) and accelerated cellular proliferation, and (3) significantly increased tendon strength by 68–91% from week 2 after AAV2-bFGF treatment and by 82–210% from week 3 after AAV2-VEGF compared with that of the controls (p < 0.05 or p < 0.01). Moreover, the transgene expression dissipated after healing was complete. These findings show that the gene transfers provide an optimistic solution to the insufficiencies of the intrinsic healing capacity of the tendon and offers an effective therapeutic possibility for patients with tendon disunion. PMID:26865366

  3. Effects of a peracetic acid disinfection protocol on the biocompatibility and biomechanical properties of human patellar tendon allografts.

    PubMed

    Lomas, R J; Jennings, L M; Fisher, J; Kearney, J N

    2004-01-01

    Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.

  4. Tissue Engineering Strategies for the Tendon/ligament-to-bone insertion

    PubMed Central

    Smith, Lester; Xia, Younan; Galatz, Leesa M.; Genin, Guy M.; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require re-attachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of re-injury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations. PMID:22185608

  5. Tendon regeneration in human and equine athletes: Ubi Sumus-Quo Vadimus (where are we and where are we going to)?

    PubMed

    Spaas, Jan H; Guest, Deborah J; Van de Walle, Gerlinde R

    2012-10-01

    Tendon injuries are one of the most common orthopaedic problems in both human and equine athletes. When a damaged tendon heals naturally, it loses a substantial part of the original strength and elasticity. Therefore, tendons recover structurally (reparation) but not functionally (regeneration) after conservative medical or surgical treatment. Since the structure and matrix composition of human and equine tendons share many similarities, the nature of tendon injuries are also strongly comparable in both species. Therefore, the evaluation of regenerative therapies in horses may have applications for future human medicine and vice versa. The current review focuses briefly on the physiology of human and equine tendon in order to better comprehend the modus operandi of this structure under pathophysiological circumstances. In addition, the reparative effects of conservative medical and surgical interventions are discussed concisely, and an extensive overview is given on the regenerative therapies that are currently being explored. For the latter, the results of equine clinical studies might prove invaluable for gaining additional insights into the treatment of human tendinopathies, since not all of these novel regenerative therapies have been evaluated in humans yet.

  6. [Tenotomy of carpal and digital flexor tendons for correction of congenital neuromyodysplasia in a calf].

    PubMed

    Sohrt, J T; Heppelmann, M; Rehage, J; Staszyk, C

    2013-01-01

    In a 7-day-old heifer calf, a bilateral flexural deformity of the forelimbs involving the digital flexor tendons, the suspensory ligament and the ulnar and radial carpal flexor tendons was diagnosed. After 2 weeks of conservative treatment consisting of manual stretching of the legs and the application of splints and wooden blocks, which were glued to the soles and extended beyond the tip of the claws, the right forelimb could be extended sufficiently to allow weight bearing, whereas the left forelimb could be passively extended to only approximately 120°. Therefore, tenotomy of the ulnar carpal flexor tendon, the digital flexor tendons and the suspensory ligament was carried out in the left leg. A support bandage was then applied to the leg for 8 weeks, after which the carpus and fetlock could be completely extended passively. Flexural deformity of the carpus caused by contracture of the carpal flexor tendons was treated by means of a tenotomy of the ulnar carpal flexor tendon proximal to the accessory carpal bone, which allowed preservation of the carpal tunnel and avoided the risk of iatrogenic damage to nerves and the carpal joint capsule.

  7. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    PubMed

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  8. Hamstring Graft Preparation Using a Modified Rolling Hitch Technique

    PubMed Central

    Hong, Chih-Kai; Chang, Chih-Hsun; Chiang, Chen-Hao; Jou, I-Ming; Su, Wei-Ren

    2014-01-01

    Anterior cruciate ligament reconstruction using double-looped hamstring autograft is a common procedure in orthopaedic practice. However, during placement of the running, locking stitches at each end of the harvested tendons, the surgeon may face several potential obstacles, including the risk of damaging the tendon, predisposing the surgeon to needle-stick injury, and extended time consumption. We report a modified rolling hitch technique for hamstring graft preparation that is quick, cost-saving, and needleless as an alternative method. The original rolling hitch technique uses a traditional knot that attaches a rope to an object; the modified rolling hitch technique was created by adding 1 more turn before finishing with a half-hitch, which may prevent suture slippage off the tendon, thus providing sufficient fixation of the suture-tendon construct. PMID:25126495

  9. Popliteal tendon transposition for stabilization of the cranial cruciate ligament deficient stifle joint in dogs: an experimental study.

    PubMed

    Monnet, E; Schwarz, P D; Powers, B

    1995-01-01

    Popliteal tendon transposition was performed in five dogs with surgically induced cranial cruciate ligament rupture. After a lateral approach to the stifle joint, the popliteal tendon was severed distal to the sesamoid bone and transposed cranially onto the tibial crest to mimic the sagittal orientation of the cranial cruciate ligament. The origin of the popliteal tendon on the lateral femoral condyle was preserved. Lameness was not clinically detectable 2 months after surgery. At 6 months postoperatively, there was minimal radiographic and histopathologic evidence of degenerative joint disease in the stifle joints that had underwent surgery. There was no gross or microscopic evidence of meniscal damage found at necropsy 6 months after surgery. Biomechanical studies are warranted before recommending the procedure.

  10. Evidence of structurally continuous collagen fibrils in tendons.

    PubMed

    Svensson, Rene B; Herchenhan, Andreas; Starborg, Tobias; Larsen, Michael; Kadler, Karl E; Qvortrup, Klaus; Magnusson, S Peter

    2017-03-01

    Tendons transmit muscle-generated force through an extracellular matrix of aligned collagen fibrils. The force applied by the muscle at one end of a microscopic fibril has to be transmitted through the macroscopic length of the tendon by mechanisms that are poorly understood. A key element in this structure-function relationship is the collagen fibril length. During embryogenesis short fibrils are produced but they grow rapidly with maturation. There is some controversy regarding fibril length in adult tendon, with mechanical data generally supporting discontinuity while structural investigations favor continuity. This study initially set out to trace the full length of individual fibrils in adult human tendons, using serial block face-scanning electron microscopy. But even with this advanced technique the required length could not be covered. Instead a statistical approach was used on a large volume of fibrils in shorter image stacks. Only a single end was observed after tracking 67.5mm of combined fibril lengths, in support of fibril continuity. To shed more light on this observation, the full length of a short tendon (mouse stapedius, 125μm) was investigated and continuity of individual fibrils was confirmed. In light of these results, possible mechanisms that could reconcile the opposing findings on fibril continuity are discussed. Connective tissues hold all parts of the body together and are mostly constructed from thin threads of the protein collagen (called fibrils). Connective tissues provide mechanical strength and one of the most demanding tissues in this regard are tendons, which transmit the forces generated by muscles. The length of the collagen fibrils is essential to the mechanical strength and to the type of damage the tissue may experience (slippage of short fibrils or breakage of longer ones). This in turn is important for understanding the repair processes after such damage occurs. Currently the issue of fibril length is contentious, but this study provides evidence that the fibrils are extremely long and likely continuous. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force.

    PubMed

    Bochkezanian, Vanesa; Newton, Robert U; Trajano, Gabriel S; Vieira, Amilton; Pulverenti, Timothy S; Blazevich, Anthony J

    2017-05-02

    Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100-200 μs) and low-to-moderate pulse frequencies (30-50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before "muscle fatigue", and the post-exercise recovery of muscle function. Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. TTI increased (145.0 ± 127.7%) in STIM only for "positive responders" to the tendon vibration (8/16 subjects), but decreased in "negative responders" (-43.5 ± 25.7%). MVIC (-8.7%) and rectus femoris electromyography (RF EMG) (-16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone.

  12. Mechanical loading stimulates ecto-ATPase activity in human tendon cells.

    PubMed

    Tsuzaki, M; Bynum, D; Almekinders, L; Faber, J; Banes, A J

    2005-09-01

    Response to external stimuli such as mechanical signals is critical for normal function of cells, especially when subjected to repetitive motion. Tenocytes receive mechanical stimuli from the load-bearing matrix as tension, compression, and shear stress during tendon gliding. Overloading a tendon by high strain, shear, or repetitive motion can cause matrix damage. Injury may induce cytokine expression, matrix metalloproteinase (MMP) expression and activation resulting in loss of biomechanical properties. These changes may result in tendinosis or tendinopathy. Alternatively, an immediate effector molecule may exist that acts in a signal-dampening pathway. Adenosine 5'-triphosphate (ATP) is a candidate signal blocker of mechanical stimuli. ATP suppresses load-inducible inflammatory genes in human tendon cells in vitro. ATP and other extracellular nucleotide signaling are regulated efficiently by two distinct mechanisms: purinoceptors via specific receptor-ligand binding and ecto-nucleotidases via the hydrolysis of specific nucleotide substrates. ATP is released from tendon cells by mechanical loading or by uridine 5'-triphosphate (UTP) stimulation. We hypothesized that mechanical loading might stimulate ecto-ATPase activity. Human tendon cells of surface epitenon (TSC) and internal compartment (TIF) were cyclically stretched (1 Hz, 0.035 strain, 2 h) with or without ATP. Aliquots of the supernatant fluids were collected at various time points, and ATP concentration (ATP) was determined by a luciferin-luciferase bioluminescence assay. Total RNA was isolated from TSC and TIF (three patients) and mRNA expression for ecto-nucleotidase was analyzed by RT-PCR. Human tendon cells secreted ATP in vitro (0.5-1 nM). Exogenous ATP was hydrolyzed within minutes. Mechanical load stimulated ATPase activity. ATP was hydrolyzed in mechanically loaded cultures at a significantly greater rate compared to no load controls. Tenocytes (TSC and TIF) expressed ecto-nucleotidase mRNA (ENTPD3 and ENPP1, ENPP2). These data suggest that motion may release ATP from tendon cells in vivo, where ecto-ATPase may also be activated to hydrolyze ATP quickly. Ecto-ATPase may act as a co-modulator in ATP load-signal modulation by regulating the half-life of extracellular purine nucleotides. The extracellular ATP/ATPase system may be important for tendon homeostasis by protecting tendon cells from responding to excessive load signals and activating injurious pathways. Copyright 2005 Wiley-Liss, Inc

  13. Biomaterials based strategies for rotator cuff repair.

    PubMed

    Zhao, Song; Su, Wei; Shah, Vishva; Hobson, Divia; Yildirimer, Lara; Yeung, Kelvin W K; Zhao, Jinzhong; Cui, Wenguo; Zhao, Xin

    2017-09-01

    Tearing of the rotator cuff commonly occurs as among one of the most frequently experienced tendon disorders. While treatment typically involves surgical repair, failure rates to achieve or sustain healing range from 20 to 90%. The insufficient capacity to recover damaged tendon to heal to the bone, especially at the enthesis, is primarily responsible for the failure rates reported. Various types of biomaterials with special structures have been developed to improve tendon-bone healing and tendon regeneration, and have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects. In this review, we first give a brief introduction of the anatomy of the rotator cuff and then discuss various design strategies to augment rotator cuff repair. Furthermore, we highlight current biomaterials used for repair and their clinical applications as well as the limitations in the literature. We conclude this article with challenges and future directions in designing more advanced biomaterials for augmentation of rotator cuff repair. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Ultrasonographic Imaging and Anti-inflammatory Therapy of Muscle and Tendon Injuries Using Polymer Nanoparticles.

    PubMed

    Kim, Gi-Wook; Kang, Changsun; Oh, Young-Bin; Ko, Myoung-Hwan; Seo, Jeong-Hwan; Lee, Dongwon

    2017-01-01

    Ultrasonography is a reliable diagnostic modality for muscle and tendon injuries, but it has been challenging to find right diagnosis of minor musculoskeletal injuries by conventional ultrasonographic imaging. A large amount of hydrogen peroxide (H 2 O 2 ) are known to be generated during tissue damages such as mechanical injury and therefore H 2 O 2 holds great potential as a diagnostic and therapeutic marker for mechanical injuries in the musculoskeletal system. We previously developed poly(vanillyl alcohol- co -oxalate) (PVAX), which rapidly scavenges H 2 O 2 and exerts antioxidant and anti-inflammatory activity in H 2 O 2 -associated diseases. Based on the notion that PVAX nanoparticles generate CO 2 bubbles through H 2 O 2 -triggered hydrolysis, we postulated that PVAX nanoparticles could serve as ultrasonographic contrast agents and therapeutic agents for musculoskeletal injuries associated with overproduction of H 2 O 2 . In the agarose gel phantom study, PVAX nanoparticles continuously generated CO 2 bubbles to enhance ultrasonographic echogenicity significantly. Contusion injury significantly elevated the level of H 2 O 2 in skeletal muscles and Achilles tendons. Upon intramuscular injection, PVAX nanoparticles significantly elevated the ultrasound contrast and suppressed inflammation and apoptosis in the contusion injury of musculoskeletal systems. We anticipate that PVAX nanoparticles hold great translational potential as theranostic agents for musculoskeletal injuries.

  15. Interactions between tenocytes and monosodium urate monohydrate crystals: implications for tendon involvement in gout.

    PubMed

    Chhana, Ashika; Callon, Karen E; Dray, Michael; Pool, Bregina; Naot, Dorit; Gamble, Greg D; Coleman, Brendan; McCarthy, Geraldine; McQueen, Fiona M; Cornish, Jillian; Dalbeth, Nicola

    2014-09-01

    Advanced imaging studies have demonstrated that urate deposition in periarticular structures, such as tendons, is common in gout. The aim of this study was to investigate the effects of monosodium urate monohydrate (MSU) crystals on tenocyte viability and function. The histological appearance of tendons in joints affected by advanced gout was examined using light microscopy. In vitro, colorimetric assays and flow cytometry were used to assess cell viability in primary rat and primary human tenocytes cultured with MSU crystals. Real-time PCR was used to determine changes in the relative mRNA expression levels of tendon-related genes, and Sirius red staining was used to measure changes in collagen deposition in primary rat tenocytes. In joint samples from patients with gout, MSU crystals were identified within the tendon, adjacent to and invading into tendon, and at the enthesis. MSU crystals reduced tenocyte viability in a dose-dependent manner. MSU crystals decreased the mRNA expression of tendon collagens, matrix proteins and degradative enzymes and reduced collagen protein deposition by tenocytes. These data indicate that MSU crystals directly interact with tenocytes to reduce cell viability and function. These interactions may contribute to tendon damage in people with advanced gout. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Treatment of acute and closed Achilles tendon ruptures by minimally invasive tenocutaneous suturing.

    PubMed

    Ding, Wenge; Yan, Weihong; Zhu, Yaping; Liu, Zhiwei

    2012-09-01

    Achilles tendon rupture is a common injury, and its complications can impair function. Numerous operations have been described for reconstructing the ruptured tendon, but these methods can compromise microcirculation in the tendon and can seriously impair its healing. Suturing with a minimally invasive tenocutaneous technique soon after the rupture and systematic functional exercise can greatly reduce the possibility of complications. Between June 1996 and February 2009, we treated 88 patients (54 males; age range, 21-66 years) with this method. After follow-up ranging from 1-7 years, the mean American Orthopedic Foot and Ankle Society ankle-hind foot score was 95 (range, 90-98), and the maximum length of postoperative scarring was 3 cm. One patient re-ruptured his Achilles tendon one year after surgery in an accident, but after 10 months, the repaired tendon was still intact. In another patient, the nervus suralis was damaged during surgery by piercing the tension suture at the near end, causing postoperative numbness and swelling. The tension suture was quickly removed, and the patient recovered well with conservative treatment. No large irregular scars, such as those sustained during immobilization, were present over the Achilles tendon. Minimally invasive percutaneous suturing can restore the original length and continuity of the Achilles tendon, is minimally invasive, and has fewer postoperative complications than other methods.

  17. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level

    PubMed Central

    Shepherd, Jennifer H.; Riley, Graham P.; Screen, Hazel R.C.

    2014-01-01

    Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques – the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. PMID:25001495

  18. Cell phenotypic variation in normal and damaged tendons

    PubMed Central

    Clegg, Peter D; Strassburg, Sandra; Smith, Roger K

    2007-01-01

    Injuries to tendons are common in both human athletes as well as in animals, such as the horse, which are used for competitive purposes. Furthermore, such injuries are also increasing in prevalence in the ageing, sedentary population. Tendon diseases often respond poorly to treatment and require lengthy periods of rehabilitation. The tendon has a unique extracellular matrix, which has developed to withstand the mechanical demands of such tensile-load bearing structures. Following injury, any repair process is inadequate and results in tissue that is distinct from original tendon tissue. There is growing evidence for the key role of the tendon cell (tenocyte) in both the normal physiological homeostasis and regulation of the tendon matrix and the pathological derangements that occur in disease. In particular, the tenocyte is considered to have a major role in effecting the subclinical matrix degeneration that is thought to occur prior to clinical disease, as well as in the severe degradative events that occur in the tendon at the onset of clinical disease. Furthermore, the tenocyte is likely to have a central role in the production of the biologically inadequate fibrocartilaginous repair tissue that develops subsequent to tendinopathy. Understanding the biology of the tenocyte is central to the development of appropriate interventions and drug therapies that will either prevent the onset of disease, or lead to more rapid and appropriate repair of injured tendon. Central to this is a full understanding of the proteolytic response in the tendon in disease by such enzymes as metalloproteinases, as well as the control of the inappropriate fibrocartilaginous differentiation. Finally, it is important that we understand the role of both intrinsic and extrinsic cellular elements in the repair process in the tendon subsequent to injury. PMID:17696903

  19. [Precise application of Traditional Chinese Medicine in minimally-invasive techniques].

    PubMed

    Dong, Fu-Hui

    2018-06-25

    The miminally-invasive techniques of traditional Chinese medicine(TCM) uses different types of acupuncture needles to treat diseased locations with special techniques. These techniques include different methods of insertion and closed incision (press cutting, sliding cutting, scrape cutting, etc.). This needling technique is based on the traditional Chinese medicine theories of Pi Bu (cutaneous), Jing Jin (sinew), Jing Luo (meridian), Wu Ti (five body structure components) and Zang Fu (organ system). Commonly used needles include: needle Dao , needle with edge, Pi needle, Shui needle, Ren needle, Gou needle, Chang Yuan needle, Bo needle and so on. The principle of this minimally-invasive technique of TCM is to achieve the greatest healing benefit with the least amount of anatomical and physiological intervention. This will result in the highest standard of health care with the lowest rehabilitative need and burden of care. In the past 20 years, through the collaborative research of several hundred hospitals across China, we systemically reviewed the best minimally invasive technique of TCM and the first line treatments for selective conditions. In 2013, the Department of Medical Affairs of the State Administration of Traditional Chinese Medicine created "Traditional Chinese Medicine Technical Manual"(General Version) and released it nationwide, its contents include: (1)Minimally invasive scar tissue release. ¹Suitable for Bi and pain syndromes of neck, shoulder, waist, buttocks and extremities. ²Degeneration causes local hypertrophy and inflammation, creating local tissue adhesion. ³There are two kind incision methods-press cutting and slide cutting. (2)Minimally invasive fascial tension release. ¹Suitable for localized fascial tension caused by trauma, overuse, or wind-cold-dampness, leading to compensatory hyperplasia. ²Long term high-stress stimulation to local fascia creates compensatory hyperplasia, Ashi points, and tissue texture changes (cords, nodules, masses). ³According to the different structural features of the needles, there are two incision methods: penetrating from the outside to the inside and pulling from inside to outside. (3)Minimally invasive decompression technique. ¹Suitable for internal pressure changes within organ cavities caused by trauma, degeneration, inflammation, such as compartment syndrome, bone marrow edema, increased intraluminal pressure in the bone marrow. ²According to the different tissues, it is categorized into soft tissue decompression, and bone decompression. (4)Minimally invasive orthopedic surgery. Applicable to some postural, developmental deformity correction, mainly through the dynamic balance method and/or static balance method. (5)Minimally invasive dissection. Suitable for fractures, tendons injury caused by deep soft tissue adhesion. (6)Minimally invasive separation. ¹Suitable for cutaneous, sinew regions, superficial adhesions due to lesions, and local post-operative incision adhesions. ²According to the structure of the needle tip, the methods are divided into sharp separation and blunt dissection. (7)Minimally invasive sustained pressure technique. ¹Suitable for neuromuscular dysfunction which causes JING (spasm) syndrome and WEI (atrophy) syndrome. ²The needle is applied with sustained pressure, without penetrating select tissue surface. This includes: nerve root sustained pressure technique; peripheral nerve sustained pressure technique; muscle sustained pressure technique; fascial contact procedure; cutaneous sustained pressure technique.(8)Minimally invasive insertion technique. ¹Suitable for systemic regulation to treat disease. ²Different organs are connected to different layers of tissue. Therefore, to treat specific conditions, specific tissues must be targeted. ³For example, back Shu points are used to treat vertigo from cervical spine issues, and spinal degeneration associated digestion issue. ⁴The internal organs can be regulated by the pathways that runs along the different layers of tissue. The types of stimulation include: meridian acupoint stimulation; cutaneous stimulation; fascia stimulation; mucle stimulation; periosteum stimulation. The clinical application of these techniques has enriched the drug-free therapies of traditional Chinese medicine and achieved excellent outcomes, but at the same time it also raises an important question. How can we apply these minimally invasive techniques to clinical practice so it can be safe and effective? In addition, how can practitioners, individually and further develop their understanding of this minimally invasive technique progressive manner? We make the following recommendations. (1)Clear diagnosis and precise application. Any approach has specific indications and choosing the correct technique comes from a comprehensive understanding of its advantages and disadvantages. Moreover, the accurate application of the technique depends the expertise of the practitioner. Through systematic review and clinical observation, we formulated the First Line Treatment, the Second Line Treatment, and the Third Line Treatment for specific conditions. Using the information gathered from research, practitioners can decide on which point is appropriate to use based on the stage of disease progression. For example, common conditions like the nerve ending tension pain(i.e. cutaneous nerve entrapment syndrome) is caused by stress concentration. There are two types of treatment for this condition: ¹Change in the response to stress state (i.e.non-invasive approach such as manual therapy and physiotherapy). ²Change in state of surrounding environment (i.e. invasive approach such as Pi Needle). Before tissue texture changes to pain point, cord, nodules, the former approach is effective. Once tissue texture changes, the latter approach is First Line Treatment. (2)Systematic training and disease progression training. The minimally invasive techniques of traditional Chinese medicine can treat many kinds of disease. To ensure its safety, organization, progressive development, practitioners are trained systematically and manage their treatment approach through disease hierarchy. Moreover, this technique should be conducted according to its technical difficulty, operating conditions, and expertise of the practitioner. The application of minimally invasive techniques of traditional Chinese medicine does not depend on the hospitals' administration system or the regulatory college of medical professionals. The minimally invasive techniques of TCM should be taught from easy to difficult, simple to complicated, and requires gradual progression by the practitioners. Eventually, the minimally invasive techniques of TCM's diagnostic and treatment protocol can be created. These protocols are currently available for reference: ¹Forming diagnosis and differential diagnosis for the conditions below requires expert diagnostic and application skills: cerebral palsy; cervical vertigo; cervical headache; cervical precordial pain; other spine-related diseases. ²The requirements for the diagnosis and differential diagnosis of such techniques are relatively high, and special training is required for the practitioner who performs this technique. The conditions below uses minimally invasive orthopedic surgery and dissection: scar contracture deformity; congenital developmental malformations; cervical Bi -syndrome; shoulder pain syndrome; knee Bi -syndrome; low back pain; cervical spondylosis; lumbar disc herniation; avascular necrosis of the femoral head; ankylosing spondylitis. ³There are no special requirements for the diagnosis and differential diagnosis of such techniques, and special training is required for the practitioner who performs this technique. The technical content is mainly decompression and scar tissue release. a)Muscle strain diseases: levator scapulae, splenius capitis, splenius cervicis, supraspinatus, infraspinatus, teres minor, teres major, serratus posterior superior, serratus posterior inferior, piriformis, gluteus maximus, gluteus medius, and gluteus minimus, erector spinae. b)Joint degenerative disorders: frozen shoulder, tennis elbow, tenosynovitis, knee osteoarthritis, and plantar fascitis. c) JING-JIN PI-BU pain syndrome (cutaneous nerve entrapment syndrome): occipital great nerve entrapment syndrome, occipital small nerve entrapment syndrome, great auricular nerve entrapment syndrome, suprascapular nerve entrapment syndrome, transverse cutaneous nerve of neck entrapment syndrome. (3)People-centred practice. The most attractive feature of the minimally invasive techniques of TCM is that they do not rely on expensive medical equipment and operating conditions. The key to applying this technique is the practitioners' technique, skill, and expertise. The necessary conditions required to successfully apply this technique is ¹practitioner understands disease progression and diagnosis; ²practitioners' skill in applying technique. We require patient-centered approach, which uses evidence based approach as the focus. We aim to seek the truth from facts, to understand the comprehensive picture, to include pertinent details, to be observant, to be goal oriented, from one to another, from outside to inside, from top to the bottom, compare right from left, through active movement and passive movements and weight-bearing movements, and assisted passive movements to determine instantaneous centre to diagnose stress concentration points. The operating technique is based on the response of patient's tissues to this technique. We must pay attention to diagnosis through palpation: layers, structure, texture, deformity, dislocation, movement characteristic, rhythmic changes. To achieve SHOU MO XIN HUI WU WEI : position, quantify, quantity, timing, and pattern. Accurate grasp of timeliness and dose efficiency. Can distinguish between local or systemic effects of treatment. Through comprehensive judgment of hands feeling, acupuncture needle feeling, and inspiration, to achieve the precious treatment requirements as indicated by the "Huangdi Neijing·Suwen" : "Puncture the bone without damaging tendons, and puncture tendons without damaging muscles, puncture the muscle without damaging pulse, puncture pulse without damaging skin, puncture skin without damaging muscle. Puncture muscle without damage tendons, puncture tendons without damaging bone... Puncture bone without damaging tendons and it means the needle passes through the tendons and arrives at the bone and work on the bone. Puncture tendons without damaging muscles, and it means the needle passes through the muscles and arrives close to the tendon. Puncture the muscle without damaging pulse and it means the needle passes the pulse and does not touch the muscle. Puncture pulse without damaging skin and it means, the needle passes through the skin without penetrating pulse. Puncture skin without damaging muscle and it means, the disease is in the skin and the needles insert into skin but does not damage muscle. Puncture muscle without damage tendons, and it means, the needle passes through the muscle and arrive on the tendon. Puncture tendons without damaging bone." Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  20. Illusory movements induced by tendon vibration in right- and left-handed people.

    PubMed

    Tidoni, Emmanuele; Fusco, Gabriele; Leonardis, Daniele; Frisoli, Antonio; Bergamasco, Massimo; Aglioti, Salvatore Maria

    2015-02-01

    Frequency-specific vibratory stimulation of peripheral tendons induces an illusion of limb movement that may be useful for restoring proprioceptive information in people with sensorimotor disability. This potential application may be limited by inter- and intra-subject variability in the susceptibility to such an illusion, which may depend on a variety of factors. To explore the influence of stimulation parameters and participants' handedness on the movement illusion, we vibrated the right and left tendon of the biceps brachii in a group of right- and left-handed people with five stimulation frequencies (from 40 to 120 Hz in step of 20 Hz). We found that all participants reported the expected illusion of elbow extension, especially after 40 and 60 Hz. Left-handers exhibited less variability in reporting the illusion compared to right-handers across the different stimulation frequencies. Moreover, the stimulation of the non-dominant arm elicited a more vivid illusion with faster onset relative to the stimulation of the dominant arm, an effect that was independent from participants' handedness. Overall, our data show that stimulation frequency, handedness and arm dominance influence the tendon vibration movement illusion. The results are discussed in reference to their relevance in linking motor awareness, improving current devices for motor ability recovery after brain or spinal damage and developing prosthetics and virtual embodiment systems.

  1. Cathepsins in Rotator Cuff Tendinopathy: Identification in Human Chronic Tears and Temporal Induction in a Rat Model.

    PubMed

    Seto, Song P; Parks, Akia N; Qiu, Yongzhi; Soslowsky, Louis J; Karas, Spero; Platt, Manu O; Temenoff, Johnna S

    2015-09-01

    While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy.

  2. Cathepsins in Rotator Cuff Tendinopathy: Identification in Human Chronic Tears and Temporal Induction in a Rat Model

    PubMed Central

    Seto, Song P.; Parks, Akia N.; Qiu, Yongzhi; Soslowsky, Louis J.; Karas, Spero; Platt, Manu O.; Temenoff, Johnna S.

    2015-01-01

    While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy. PMID:25558848

  3. Harvesting of the sural nerve with a tendon stripper.

    PubMed

    Jaroszynski, G; Johnston, G H

    1996-01-01

    The nerve most commonly used for peripheral nerve reconstruction is the sural nerve. The nerve can be dissected free through one long calf incision, by utilizing multiple small incisions, or by using a tendon stripper. We studied 12 above-knee amputation specimens harvesting the nerve in the ways described. We found that the length of nerve harvested averaged 32, 36, and 25 cm for the open, limited open, and stripper techniques, respectively. Epineurial damage occurred with the stripper, but no perineurial damage was documented histologically. We concluded that the closed method (stripper) of harvesting sural nerve would provide quality graft material, but of unpredictable length. When reliably long segments of nerve are required, at least a limited open or an open approach for harvest is recommended.

  4. Spontaneous tendon rupture in systemic lupus erythematosus: association with Jaccoud's arthropathy.

    PubMed

    Alves, E M; Macieira, J C; Borba, E; Chiuchetta, F A; Santiago, M B

    2010-03-01

    Tendon rupture has rarely been described in patients with systemic lupus erythematosus. From observation of three cases of Jaccoud's arthropathy with tendon rupture, and considering that this arthropathy is more related to an inflammatory process of the tendon sheath than to synovitis per se, the intention of this study was to review the cases of tendon rupture in patients with systemic lupus erythematosus, in the hope of determining the frequency of Jaccoud's arthropathy associated with this complication. Systematic review using MEDLINE, Scielo and LILACS databases (1966 to 2009) and the following keywords: systemic lupus erythematosus, tendon rupture, Jaccoud's arthropathy. Secondary references were additionally obtained. Additionally, three Brazilian systemic lupus erythematosus patients who developed tendon rupture are described. Only 40 articles obtained fulfilled the previously established criteria. They were all case reports; the number of cases reported was 52 which, together with the three cases presented herein add up to 55 cases. Forty-six patients were women aged between 19 and 71 years, with a mean age of 40.1 +/- 12.4 years, and the average duration of the disease was 10 years. The most frequently observed rupture sites were the patellar and Achilles' tendons. While almost all patients described were on various doses of corticosteroids, 16 patients concomitantly had Jaccoud's arthropathy (29%). In conclusion, the association between Jaccoud's arthropathy and tendon rupture in systemic lupus erythematosus has been underestimated. As almost one-third of the systemic lupus erythematosus patients with tendon rupture also have Jaccoud's arthropathy, this arthropathy may be recognized as risk marker for tendon rupture.

  5. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    PubMed Central

    Jung, Ho-Joong; Fisher, Matthew B; Woo, Savio L-Y

    2009-01-01

    Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to obtain their biomechanical properties. Specifically, we hope the reader will pay attention to how the properties of these tissues can be altered due to various experimental and biologic factors. Following this background material, we will present how biomechanics can be applied to gain an understanding of the mechanisms as well as clinical management of various ligament and tendon ailments. To conclude, new technology, including imaging and robotics as well as functional tissue engineering, that could form novel treatment strategies to enhance healing of ligament and tendon are presented. PMID:19457264

  6. Genome-wide transcriptional profiling data from chronic cutaneous lupus erythematosus (CCLE) peripheral blood.

    PubMed

    Dey-Rao, R; Sinha, A A

    2015-03-01

    The disease Lupus erythematosus (LE), exhibits a variety of clinical manifestations with potentially wide-ranging multi-organ damage to joints, tendons, kidney, lung, heart, blood vessels, central nervous system and skin [1,2] Systemic changes are likely to trigger organ specific manifestation of the disease. Here, we provide the data examined to address the gap in knowledge regarding causes and mechanisms contributing to the autoimmune attack on skin in chronic cutaneous lupus erythematosus (CCLE). The raw gene expression data files (CEL files) are provided with this article [3].

  7. Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants.

    PubMed

    Becker, Roland; Wirz, Dieter; Wolf, Cornelius; Göpfert, Beat; Nebelung, Wolfgang; Friederich, Niklaus

    2005-05-01

    Biodegradable implants are frequently used for meniscus repair. Articular cartilage damage has been reported recently after meniscus repair with biodegradable implants. The aim of the study was to investigate the meniscofemoral contact pressure at the posterior horn of the medial and lateral meniscus after repair of bucket-handle lacerations. Specimens were mounted in a materials testing machine (Bionix 858, MTS) which was equipped with a load cell. The quadriceps tendon was attached to a hydraulic cylinder, and knee motion was controlled via tension of the quadriceps tendon. A piezo-resistive system (Tekscan, Boston, MA, USA) measured the meniscofemoral contact pressure. Five different types of biodegradable implants (Arrow, Dart, Fastener, Stinger and Meniscal Screw) and horizontal suture (no. 2 Ethibond) were tested. The knee was extended from 90 degrees of flexion to 0 degrees under a constant load of 350 N due to adjustment of the tension force of the quadriceps tendon. The femorotibial pressure and contact area were recorded at 0 degree, 30 degrees, 60 degrees and 90 degrees of flexion. The meniscofemoral pressure did not increase after meniscus repair with biodegradable implants or sutures. The meniscofemoral peak pressure at the posterior horn was 1.46+/-1.54 MPa in the medial compartment and 1.08+/-1.17 MPa in the lateral compartment at full knee extension. The meniscofemoral pressure increased significantly in both compartments with knee flexion from 0 degree to 90 degrees. Biodegradable implants for meniscus repair do not affect the meniscofemoral pressure. However, there remains a risk of damage to the cartilage when barbed implants are used. If the implant is not entirely advanced into the meniscus, the sharp head or some of the barbs at the column of the implant may come into direct contact with the articular cartilage of the femoral condyle or tibial plateau. The authors presume that incorrect positioning of the implant seems to be the major reason for cartilage damage.

  8. Exposure of a tendon extracellular matrix to synovial fluid triggers endogenous and engrafted cell death: A mechanism for failed healing of intrathecal tendon injuries.

    PubMed

    Garvican, Elaine R; Salavati, Mazdak; Smith, Roger K W; Dudhia, Jayesh

    2017-09-01

    The purpose of this study was to investigate the effect of normal synovial fluid (SF) on exposed endogenous tendon-derived cells (TDCs) and engrafted mesenchymal stem cells (MSCs) within the tendon extracellular matrix. Explants from equine superficial digital flexor (extra-synovial) and deep digital flexor tendons (DDFTs) from the compressed, intra-synovial and the tensile, extra-synovial regions were cultured in allogeneic or autologous SF-media. Human hamstring explants were cultured in allogeneic SF. Explant viability was assessed by staining. Proliferation of equine monolayer MSCs and TDCs in SF-media and co-culture with DDFT explants was determined by alamarblue®. Non-viable Native Tendon matrices (NNTs) were re-populated with MSCs or TDCs and cultured in SF-media. Immunohistochemical staining of tendon sections for the apoptotic proteins caspase-3, -8, and -9 was performed. Contact with autologous or allogeneic SF resulted in rapid death of resident tenocytes in equine and human tendon. SF did not affect the viability of equine epitenon cells, or of MSCs and TDCs in the monolayer or indirect explant co-culture. MSCs and TDCs, engrafted into NNTs, died when cultured in SF. Caspase-3, -8, and -9 expression was the greatest in SDFT explants exposed to allogeneic SF. The efficacy of cells administered intra-synovially for tendon lesion repair is likely to be limited, since once incorporated into the matrix, cells become vlnerable to the adverse effects of SF. These observations could account for the poor success rate of intra-synovial tendon healing following damage to the epitenon and contact with SF, common with most soft tissue intra-synovial pathologies.

  9. Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds

    PubMed Central

    Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.

    2015-01-01

    Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095

  10. Tenogenesis of bone marrow-, adipose-, and tendon-derived stem cells in a dynamic bioreactor.

    PubMed

    Youngstrom, Daniel W; LaDow, Jade E; Barrett, Jennifer G

    2016-11-01

    Tendons are frequently damaged and fail to regenerate, leading to pain, loss of function, and reduced quality of life. Mesenchymal stem cells (MSCs) possess clinically useful tissue-regenerative properties and have been exploited for use in tendon tissue engineering and cell therapy. However, MSCs exhibit phenotypic heterogeneity based on the donor tissue used, and the efficacy of cell-based treatment modalities may be improved by optimizing cell source based on relative differentiation capacity. Equine MSCs were isolated from bone marrow (BM), adipose (AD), and tendon (TN), expanded in monolayer prior to seeding on decellularized tendon scaffolds (DTS), and cell-laden constructs were placed in a bioreactor designed to mimic the biophysical environment of the tendon. It was hypothesized that TN MSCs would differentiate toward a tendon cell phenotype better than BM and AD MSCs in response to a conditioning period involving cyclic mechanical stimulation for 1 hour per day at 3% strain and 0.33 Hz. All cell types integrated into DTS adopted an elongated morphology similar to tenocytes, expressed tendon marker genes, and improved tissue mechanical properties after 11 days. TN MSCs expressed the greatest levels of scleraxis, collagen type-I, and cartilage oligomeric matrix protein. Major histocompatibility class-II protein mRNA expression was not detected in any of the MSC types, suggesting low immunogenicity for allogeneic transplantation. The results suggest that TN MSCs are the ideal cell type for regenerative medicine therapies for tendinopathies, exhibiting the most mature tendon-like phenotype in vitro. When TN MSCs are unavailable, BM or AD MSCs may serve as robust alternatives.

  11. Beneficial Effects of Autologous Bone Marrow-Derived Mesenchymal Stem Cells in Naturally Occurring Tendinopathy

    PubMed Central

    Smith, Roger Kenneth Whealands; Werling, Natalie Jayne; Dakin, Stephanie Georgina; Alam, Rafiqul; Goodship, Allen E.; Dudhia, Jayesh

    2013-01-01

    Tendon injuries are a common age-related degenerative condition where current treatment strategies fail to restore functionality and normal quality of life. This disease also occurs naturally in horses, with many similarities to human tendinopathy making it an ideal large animal model for human disease. Regenerative approaches are increasingly used to improve outcome involving mesenchymal stem cells (MSCs), supported by clinical data where injection of autologous bone marrow derived MSCs (BM-MSCs) suspended in marrow supernatant into injured tendons has halved the re-injury rate in racehorses. We hypothesized that stem cell therapy induces a matrix more closely resembling normal tendon than the fibrous scar tissue formed by natural repair. Twelve horses with career-ending naturally-occurring superficial digital flexor tendon injury were allocated randomly to treatment and control groups. 1X107 autologous BM-MSCs suspended in 2 ml of marrow supernatant were implanted into the damaged tendon of the treated group. The control group received the same volume of saline. Following a 6 month exercise programme horses were euthanized and tendons assessed for structural stiffness by non-destructive mechanical testing and for morphological and molecular composition. BM-MSC treated tendons exhibited statistically significant improvements in key parameters compared to saline-injected control tendons towards that of normal tendons and those in the contralateral limbs. Specifically, treated tendons had lower structural stiffness (p<0.05) although no significant difference in calculated modulus of elasticity, lower (improved) histological scoring of organisation (p<0.003) and crimp pattern (p<0.05), lower cellularity (p<0.007), DNA content (p<0.05), vascularity (p<0.03), water content (p<0.05), GAG content (p<0.05), and MMP-13 activity (p<0.02). Treatment with autologous MSCs in marrow supernatant therefore provides significant benefits compared to untreated tendon repair in enhancing normalisation of biomechanical, morphological, and compositional parameters. These data in natural disease, with no adverse findings, support the use of this treatment for human tendon injuries. PMID:24086616

  12. Construction Condition and Damage Monitoring of Post-Tensioned PSC Girders Using Embedded Sensors.

    PubMed

    Shin, Kyung-Joon; Lee, Seong-Cheol; Kim, Yun Yong; Kim, Jae-Min; Park, Seunghee; Lee, Hwanwoo

    2017-08-10

    The potential for monitoring the construction of post-tensioned concrete beams and detecting damage to the beams under loading conditions was investigated through an experimental program. First, embedded sensors were investigated that could measure pre-stress from the fabrication process to a failure condition. Four types of sensors were installed on a steel frame, and the applicability and the accuracy of these sensors were tested while pre-stress was applied to a tendon in the steel frame. As a result, a tri-sensor loading plate and a Fiber Bragg Grating (FBG) sensor were selected as possible candidates. With those sensors, two pre-stressed concrete flexural beams were fabricated and tested. The pre-stress of the tendons was monitored during the construction and loading processes. Through the test, it was proven that the variation in thepre-stress had been successfully monitored throughout the construction process. The losses of pre-stress that occurred during a jacking and storage process, even those which occurred inside the concrete, were measured successfully. The results of the loading test showed that tendon stress and strain within the pure span significantly increased, while the stress in areas near the anchors was almost constant. These results prove that FBG sensors installed in a middle section can be used to monitor the strain within, and the damage to pre-stressed concrete beams.

  13. Construction Condition and Damage Monitoring of Post-Tensioned PSC Girders Using Embedded Sensors

    PubMed Central

    Shin, Kyung-Joon; Lee, Seong-Cheol; Kim, Yun Yong; Kim, Jae-Min; Park, Seunghee; Lee, Hwanwoo

    2017-01-01

    The potential for monitoring the construction of post-tensioned concrete beams and detecting damage to the beams under loading conditions was investigated through an experimental program. First, embedded sensors were investigated that could measure pre-stress from the fabrication process to a failure condition. Four types of sensors were installed on a steel frame, and the applicability and the accuracy of these sensors were tested while pre-stress was applied to a tendon in the steel frame. As a result, a tri-sensor loading plate and a Fiber Bragg Grating (FBG) sensor were selected as possible candidates. With those sensors, two pre-stressed concrete flexural beams were fabricated and tested. The pre-stress of the tendons was monitored during the construction and loading processes. Through the test, it was proven that the variation in thepre-stress had been successfully monitored throughout the construction process. The losses of pre-stress that occurred during a jacking and storage process, even those which occurred inside the concrete, were measured successfully. The results of the loading test showed that tendon stress and strain within the pure span significantly increased, while the stress in areas near the anchors was almost constant. These results prove that FBG sensors installed in a middle section can be used to monitor the strain within, and the damage to pre-stressed concrete beams. PMID:28796156

  14. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level.

    PubMed

    Shepherd, Jennifer H; Riley, Graham P; Screen, Hazel R C

    2014-10-01

    Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques - the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Tendon Driven Finger Actuation System

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Reich, David M. (Inventor); Bridgwater, Lyndon (Inventor); Linn, Douglas Martin (Inventor); Askew, Scott R. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Hargrave, Brian (Inventor); Valvo, Michael C. (Inventor); Abdallah, Muhammad E. (Inventor); hide

    2013-01-01

    A humanoid robot includes a robotic hand having at least one finger. An actuation system for the robotic finger includes an actuator assembly which is supported by the robot and is spaced apart from the finger. A tendon extends from the actuator assembly to the at least one finger and ends in a tendon terminator. The actuator assembly is operable to actuate the tendon to move the tendon terminator and, thus, the finger.

  16. Hyaluronic acid injections protect patellar tendon from detraining-associated damage.

    PubMed

    Frizziero, Antonio; Salamanna, Francesca; Giavaresi, Gianluca; Ferrari, Andrea; Martini, Lucia; Marini, Marina; Veicsteinas, Arsenio; Maffulli, Nicola; Masiero, Stefano; Fini, Milena

    2015-09-01

    Having previously demonstrated that detraining affects patellar tendon (PT) proteoglycan content and collagen fiber organization, we undertook the present study with two aims: to improve knowledge on the adaptation of PT and its enthesis to detraining from a histological and histomorphometric point of view, and to investigate the hypothesis that repeated peri-patellar injections of hyaluronic acid (HA) on detrained PT may reduce and limit detrained associated-damage. Twenty-four male Sprague-Dawley rats were divided into 3 groups: Untrained (n=6), Trained (n=6) (10 wks-treadmill) and Detrained (n=12). In the detrained rats, the left tendon was untreated while the right tendon received repeated peri-patellar injections of either HA or saline (NaCl). Structure and morphology of PTs (modified Movin score, tear density, collagen type I and III) and enthesis (cell morphology, chondrocyte cluster formation, tidemark integrity, matrix staining and vascularization) were evaluated. The left PT and enthesis of the Detrained groups showed altered structure and morphology with the highest Movin score values, the highest percentage of collagen III and the lowest of collagen I; the lowest score values were observed in the Trained and Detrained-HA groups. Detrained-NaCl PTs showed the highest collagen III and the lowest collagen I values with respect to Detrained-HA PTs. This study strengthens previously published data showing the alteration in tendon and enthesis morphology due to discontinuation of training, and provides new data showing that treatment with HA is effective in the maintenance of the structural properties of PT and enthesis in Detrained rats. Such beneficial effects could play a significant role in the management of conservative and rehabilitation strategies in athletes that change type, intensity and duration of training.

  17. Basic radiological assessment of synovial diseases: a pictorial essay

    PubMed Central

    Turan, Aynur; Çeltikçi, Pınar; Tufan, Abdurrahman; Öztürk, Mehmet Akif

    2017-01-01

    The synovium is a specialized tissue lining the synovial joints, bursae, and tendon sheaths of the body. It is affected by various localized or systemic disorders. Synovial diseases can be classified as inflammatory, infectious, degenerative, traumatic, hemorrhagic, and neoplastic. Damage in other intraarticular structures, particularly cartilages, generally occurs as a part of pathologic processes involving the synovium, leading to irreversible joint destruction. Imaging has an essential role in the early detection of synovial diseases prior to irreversible joint damage. Obtaining and understanding characteristic imaging findings of synovial diseases enables a proper diagnosis for early treatment. This article focuses on the recent literature that is related with the role of imaging in synovial disease. PMID:28638696

  18. Ultrasonographic Imaging and Anti-inflammatory Therapy of Muscle and Tendon Injuries Using Polymer Nanoparticles

    PubMed Central

    Kim, Gi-Wook; Kang, Changsun; Oh, Young-Bin; Ko, Myoung-Hwan; Seo, Jeong-Hwan; Lee, Dongwon

    2017-01-01

    Ultrasonography is a reliable diagnostic modality for muscle and tendon injuries, but it has been challenging to find right diagnosis of minor musculoskeletal injuries by conventional ultrasonographic imaging. A large amount of hydrogen peroxide (H2O2) are known to be generated during tissue damages such as mechanical injury and therefore H2O2 holds great potential as a diagnostic and therapeutic marker for mechanical injuries in the musculoskeletal system. We previously developed poly(vanillyl alcohol-co-oxalate) (PVAX), which rapidly scavenges H2O2 and exerts antioxidant and anti-inflammatory activity in H2O2-associated diseases. Based on the notion that PVAX nanoparticles generate CO2 bubbles through H2O2-triggered hydrolysis, we postulated that PVAX nanoparticles could serve as ultrasonographic contrast agents and therapeutic agents for musculoskeletal injuries associated with overproduction of H2O2. In the agarose gel phantom study, PVAX nanoparticles continuously generated CO2 bubbles to enhance ultrasonographic echogenicity significantly. Contusion injury significantly elevated the level of H2O2 in skeletal muscles and Achilles tendons. Upon intramuscular injection, PVAX nanoparticles significantly elevated the ultrasound contrast and suppressed inflammation and apoptosis in the contusion injury of musculoskeletal systems. We anticipate that PVAX nanoparticles hold great translational potential as theranostic agents for musculoskeletal injuries. PMID:28744328

  19. The biophysical characteristics of human composite flexor tendon allograft for upper extremity reconstruction.

    PubMed

    DeGeorge, Brent R; Rodeheaver, George T; Drake, David B

    2014-01-01

    Devastating volar hand injuries with significant damage to the skin and soft tissues, pulley structures and fibro-osseous sheath, flexor tendons, and volar plates pose a major problem to the reconstructive hand surgeon. Despite advances in tendon handling, operative technique, and postoperative hand rehabilitation, patients who have undergone flexor tendon reconstruction are often plagued by chronic pain, stiffness, and decreased range of motion with resultant decreased ability to work and poor quality of life. In this article, we expand the technique of human composite flexor tendon allografts (CFTAs), pioneered by Dr E.E. Peacock, Jr, which consist of both the intrasynovial and extrasynovial flexor digitorum superficialis and flexor digitorum profundus tendons and their respective fibro-osseous sheath consisting of the digital pulley structures, periosteum, and volar plates procured from cadaveric donors with the use of modern tissue processing techniques. Human cadaveric CFTAs were procured and divided into 2 groups-unprocessed CFTAs and processed CFTAs, which are cleansed and sterilized to a sterility assurance level of 10(-6). Physical length and width relationships as well as tensile strength and gliding resistance assessments were recorded pre-tissue and post-tissue processing. The histologic properties of the composite allografts were assessed before and after tissue processing. There was no significant difference with respect to physical properties of the composite allografts before or after tissue processing. The processed composite allografts demonstrated equivalent maximum load to failure and elastic modulus compared to unprocessed tendons. The gliding resistance of the composite tendon allografts was not significantly different between the 2 groups. The use of CFTAs addresses the issues of adhesion formation and lack of suitable donor material by providing a source of intrasynovial tendon in its unaltered fibro-osseous sheath without donor morbidity. This approach represents an important step toward designing an ideal material for complex flexor tendon reconstruction, which takes advantage of an intrasynovial flexor tendon in its native fibro-osseous sheath without the need for additional donor morbidity using a construct which can be engineered to have minimal tissue reactivity, negligible potential for disease transmission, and improved tendon healing properties versus standard tendon allograft.

  20. Burn depth determination using high-speed polarization-sensitive Mueller optical coherence tomography with continuous polarization modulation

    NASA Astrophysics Data System (ADS)

    Todorović, Miloš; Ai, Jun; Pereda Cubian, David; Stoica, George; Wang, Lihong

    2006-02-01

    National Health Interview Survey (NHIS) estimates more than 1.1 million burn injuries per year in the United States, with nearly 15,000 fatalities from wounds and related complications. An imaging modality capable of evaluating burn depths non-invasively is the polarization-sensitive optical coherence tomography. We report on the use of a high-speed, fiber-based Mueller-matrix OCT system with continuous source-polarization modulation for burn depth evaluation. The new system is capable of imaging at near video-quality frame rates (8 frames per second) with resolution of 10 μm in biological tissue (index of refraction: 1.4) and sensitivity of 78 dB. The sample arm optics is integrated in a hand-held probe simplifying the in vivo experiments. The applicability of the system for burn depth determination is demonstrated using biological samples of porcine tendon and porcine skin. The results show an improved imaging depth (1 mm in tendon) and a clear localization of the thermally damaged region. The burnt area determined from OCT images compares well with the histology, thus proving the system's potential for burn depth determination.

  1. Efficacy of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for the quantitative evaluation of the structural integrity of superficial digital flexor tendons in horses.

    PubMed

    van Schie, H T; Bakker, E M; Jonker, A M; van Weeren, P R

    2001-07-01

    To evaluate effectiveness of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for quantitative evaluation of tendon structural integrity in horses. 4 superficial digital flexor tendons (2 damaged tendons, 2 normal tendons). Transverse ultrasonographic images that precisely matched histologic sections were obtained in fixed steps along the long axis of each tendon. Distribution, intensity, and delineation of structure-related echoes, quantitatively expressed as the correlation ratio and steadiness ratio , were compared with histologic findings in tissue that was normal or had necrosis, early granulation, late granulation, early fibrosis, or inferior repair. In normal tendon, the even distribution of structure-related echoes with high intensity and sharp delineation yielded high correlation ratio and steadiness ratio. In areas of necrosis, collapsed endotendon septa yielded solid but blurred structure-related echoes (high correlation ration and low steadiness ratio). In early granulation tissue, complete lack of organization caused zero values for both ratios. In late granulation tissue, reorganization and swollen endotendon septa yielded poorly delineated structure-related echoes (high correlation ratio, low steadiness ratio). In early fibrosis, rearrangement of bundles resulted in normal correlation ration and slightly low steadiness ratio. In inferior repair, the almost complete lack of structural reorganization resulted in heterogeneous poorly delineated low-intensity echoes (low correlation ratio and steadiness ratio). The combination of correlation ratio and steadiness ratio accurately reflects histopathologic findings, making computerized correlation of ultrasonographic images an efficient tool for quantitative evaluation of tendon structural integrity.

  2. Vascular abnormalities of the distal deep digital flexor tendon in 8 draught horses identified on histological examination.

    PubMed

    Crişan, Melania Ioana; Damian, Aurel; Gal, Adrian; Miclăuş, Viorel; Cernea, Cristina L; Denoix, Jean-Marie

    2013-08-01

    The purpose of this study was to provide a detailed description of the vascular changes in the distal part of deep digital flexor tendon (DDFT). Eight isolated forelimbs were collected from 8 horses with DDF tendinopathy diagnosed post-mortem by ultrasound and gross anatomopathological examination. The samples were fixed in 10% neutral buffered formalin, softened in 4% phenol and dehydrated with ethylic alcohol. Goldner's Trichrome staining method was used. The histopathological examination revealed vascular proliferation associated with structural disorders of blood vessels. Angiogenesis, fibroplasia and consecutive hypertrophy of the vascular wall with or without vascular occlusion were the most common findings. Other histopathological findings were: endothelial cell edema, progressive metaplasia from squamous to cubic cells, vascular wall hyalinization, endothelial cells apoptosis/necrosis and endothelial desquamation. These results demonstrated damage of the distal deep digital flexor tendon vasculature which may progressively alter the structural integrity of the tendon and contribute to degenerative lesions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Tendon fatigue in response to mechanical loading

    PubMed Central

    Andarawis-Puri, N.; Flatow, E. L.

    2015-01-01

    Tendinopathies are commonly attributable to accumulation of sub-rupture fatigue damage from repetitive use. Data is limited to late stage disease from patients undergoing surgery, motivating development of animal models, such as ones utilizing treadmill running or repetitive reaching, to investigate the progression of tendinopathies. We developed an in vivo model using the rat patellar tendon that allows control of the loading directly applied to the tendon. This manuscript discusses the response of tendons to fatigue loading and applications of our model. Briefly, the fatigue life of the tendon was used to define low, moderate and high levels of fatigue loading. Morphological assessment showed a progression from mild kinks to fiber disruption, for low to high level fatigue loading. Collagen expression, 1 and 3 days post loading, showed more modest changes for low and moderate than high level fatigue loading. Protein and mRNA expression of Ineterleukin-1β and MMP-13 were upregulated for moderate but not low level fatigue loading. Moderate level (7200 cycles) and 100 cycles of fatigue loading resulted in a catabolic and anabolic molecular profile respectively, at both 1 and 7 days post loading. Results suggest unique mechanisms for different levels of fatigue loading that are distinct from laceration. PMID:21625047

  4. Multiple tendon ruptures of unknown etiology.

    PubMed

    Axibal, Derek P; Anderson, John G

    2013-10-01

    Tendon ruptures are common findings in foot and ankle practice. The etiology of tendon ruptures tends to be multifactorial-usually due to a combination of trauma, effects of systemic diseases, adverse effects of medications, and obesity. We present an unusual case of right Achilles tendinitis, left Achilles tendon rupture, bilateral peroneus longus tendon rupture, and left peroneus brevis tendon rupture of unknown etiology. This case report highlights the need for research for other possible, lesser known etiologies of tendon pathology. Therapeutic, Level IV, Case Study.

  5. Peroneal perforator-based peroneus longus tendon and sural neurofasciocutaneous composite flap transfer for a large soft-tissue defect of the forearm: A case report.

    PubMed

    Hayashida, Kenji; Saijo, Hiroto; Fujioka, Masaki

    2018-01-01

    We describe the use of a composite flap composed of a sural neurofasciocutaneous flap and a vascularized peroneus longus tendon for the reconstruction of severe composite forearm tissue defects in a patient. A 43-year-old man had his left arm caught in a conveyor belt resulting in a large soft-tissue defect of 18 × 11 cm over the dorsum forearm. The extensor carpi radialis, superficial radial nerve, and radial artery were severely damaged. A free neurofasciocutaneous composite flap measuring 16 × 11 cm was outlined on the patient's left lower leg to allow simultaneous skin, tendon, nerve, and artery reconstruction. The flap, which included the peroneus longus tendon, was elevated on the subfascial plane. After the flap was transferred to the recipient site, the peroneal artery was anastomosed to the radial artery in a flow-through manner. The vascularized tendon graft with 15 cm in length was used to reconstruct the extensor carpi radialis longus tendon defect using an interlacing suture technique. As the skin paddle of the sural neurofasciocutaneous flap and the vascularized peroneus longus tendon graft were linked by the perforator and minimal fascial tissue, the skin paddle was able to rotate and slide with comparative ease. The flap survived completely without any complications. The length of follow-up was 12 months and was uneventful. Range of motion of his left wrist joint was slightly limited to 75 degrees. This novel composite flap may be useful for reconstructing long tendon defects associated with extensive forearm soft tissue defects. © 2016 Wiley Periodicals, Inc.

  6. Unbonded Prestressed Columns for Earthquake Resistance

    DOT National Transportation Integrated Search

    2012-05-01

    Modern structures are able to survive significant shaking caused by earthquakes. By implementing unbonded post-tensioned tendons in bridge columns, the damage caused by an earthquake can be significantly lower than that of a standard reinforced concr...

  7. Force Model for Control of Tendon Driven Hands

    NASA Technical Reports Server (NTRS)

    Pena, Edward; Thompson, David E.

    1997-01-01

    Knowing the tendon forces generated for a given task such as grasping via a model, an artificial hand can be controlled. A two-dimensional force model for the index finger was developed. This system is assumed to be in static equilibrium, therefore, the equations of equilibrium were applied at each joint. Constraint equations describing the tendon branch connectivity were used. Gaussian elimination was used to solve for the unknowns of the Linear system. Results from initial work on estimating tendon forces in post-operative hands during active motion therapy were discussed. The results are important for understanding the effects of hand position on tendon tension, elastic effects on tendon tension, and overall functional anatomy of the hand.

  8. Detection of partial-thickness tears in ligaments and tendons by Stokes-polarimetry imaging

    NASA Astrophysics Data System (ADS)

    Kim, Jihoon; John, Raheel; Walsh, Joseph T.

    2008-02-01

    A Stokes polarimetry imaging (SPI) system utilizes an algorithm developed to construct degree of polarization (DoP) image maps from linearly polarized light illumination. Partial-thickness tears of turkey tendons were imaged by the SPI system in order to examine the feasibility of the system to detect partial-thickness rotator cuff tear or general tendon pathology. The rotating incident polarization angle (IPA) for the linearly polarized light provides a way to analyze different tissue types which may be sensitive to IPA variations. Degree of linear polarization (DoLP) images revealed collagen fiber structure, related to partial-thickness tears, better than standard intensity images. DoLP images also revealed structural changes in tears that are related to the tendon load. DoLP images with red-wavelength-filtered incident light may show tears and related organization of collagen fiber structure at a greater depth from the tendon surface. Degree of circular polarization (DoCP) images exhibited well the horizontal fiber orientation that is not parallel to the vertically aligned collagen fibers of the tendon. The SPI system's DOLP images reveal alterations in tendons and ligaments, which have a tissue matrix consisting largely of collagen, better than intensity images. All polarized images showed modulated intensity as the IPA was varied. The optimal detection of the partial-thickness tendon tears at a certain IPA was observed. The SPI system with varying IPA and spectral information can improve the detection of partial-thickness rotator cuff tears by higher visibility of fiber orientations and thereby improve diagnosis and treatment of tendon related injuries.

  9. Tensile properties of craniofacial tendons in the mature and aged zebrafish

    PubMed Central

    Shah, Rishita R.; Nerurkar, Nandan L.; Wang, Calvin; Galloway, Jenna L.

    2015-01-01

    The zebrafish Danio rerio is a powerful model for the study of development, regenerative biology, and human disease. However, the analysis of load-bearing tissues such as tendons and ligaments has been limited in this system. This is largely due to technical limitations that preclude accurate measurement of their mechanical properties. Here, we present a custom tensile testing system that applies nano-Newton scale forces to zebrafish tendons as small as 1 mm in length. Tendon properties were remarkably similar to mammalian tendons, including stress-strain nonlinearity and a linear modulus (515±152 MPa) that aligned closely with mammalian data. Additionally, a simple exponential constitutive law used to describe tendon mechanics was successfully fit to zebrafish tendons; the associated material constants agreed with literature values for mammalian tendons. Finally, mature and aged zebrafish comparisons revealed a significant decline in mechanical function with age. Based on the exponential constitutive model, age related changes were primarily caused by a reduction in nonlinearity (e.g. changes in collagen crimp or fiber recruitment). These findings demonstrate the utility of zebrafish as a model to study tendon biomechanics in health and disease. Moreover, these findings suggest that tendon mechanical behavior is highly conserved across vertebrates. PMID:25665155

  10. Rotator cuff healing after continuous subacromial bupivacaine infusion: an in vivo rabbit study

    PubMed Central

    FRIEL, NICOLE A.; WANG, VINCENT M.; SLABAUGH, MARK A.; WANG, FANCHIA; CHUBINSKAYA, SUSAN; COLE, BRIAN J.

    2013-01-01

    Background The objective of this study was to evaluate the effects of continuous subacromial bupivacaine infusion on supraspinatus muscle and rotator cuff tendon healing via gross, biomechanical, and histologic analyses. Methods Thirty-three New Zealand White rabbits underwent unilateral supraspinatus transection and rotator cuff repair (RCR). Rabbits were assigned to 1 of 3 groups: (1)RCR only, (2)RCR with continuous saline infusion for 48 hours, or (3)RCR with continuous 0.25% bupivacaine with epinephrine (1:200,000) infusion for 48 hours. Rabbits were sacrificed at either 2 (for histologic assessment) or 8 weeks post-operatively (for biomechanical and histologic assessment). Results Tensile testing showed significantly higher load to failure in intact tendons compared to repaired tendons (p<0.01); however, no statistical differences were detected among RCR only, RCR Saline, and RCR Bupivacaine groups. Histologically, the enthesis of repaired tendons showed increased cellularity and disorganized collagen fibers compared to intact tendons, with no differences between treatment groups. Muscle histology demonstrated scattered degenerative muscle fibers at 2 weeks in both RCR Saline and RCR Bupivacaine, but no degeneration was noted at 8 weeks. Conclusions The healing supraspinatus tendons exposed to bupivacaine infusion showed similar histologic and biomechanical characteristics compared to untreated and saline infused RCR groups. Muscle histology showed fiber damage at 2 weeks for both the saline and bupivacaine treated groups, with no apparent disruption at 8 weeks, suggesting a recovery process. Therefore, subacromial bupivacaine infusion in this rabbit rotator cuff model does not appear to impair muscle or tendon following acute injury and repair. Level Of Evidence Basic science study PMID:22818894

  11. An electrospun polydioxanone patch for the localisation of biological therapies during tendon repair.

    PubMed

    Hakimi, O; Murphy, R; Stachewicz, U; Hislop, S; Carr, A J

    2012-10-23

    Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure rate of these repairs is high, estimated at up to 75 %. Studies have shown that in late disease stages the tendon itself is extremely degenerate, with reduced cell numbers and poor matrix organisation. Thus, it has been suggested that adding biological factors such as platelet rich plasma (PRP) and mesenchymal stem cells could improve healing. However, the articular capsule of the glenohumeral joint and the subacromial bursa are large spaces, and injecting beneficial factors into these sites does not ensure localisation to the area of tendon damage. Thus, the aim of this study was to develop a biocompatible patch for improving the healing rates of rotator cuff repairs. The patch will create a confinement around the repair area and will be used to guide injections to the vicinity of the surgical repair. Here, we characterised and tested a preliminary prototype of the patch utilising in vitro tools and primary tendon-derived cells, showing exceptional biocompatibility despite rapid degradation, improved cell attachment and that cells could migrate across the patch towards a chemo-attractant. Finally, we showed the feasibility of detecting the patch using ultrasound and injecting liquid into the confinement ex vivo. There is a potential for using this scaffold in the surgical repair of interfaces such as the tendon insertion in the rotator cuff, in conjunction with beneficial factors.

  12. Using the zebrafish to understand tendon development and repair

    PubMed Central

    Chen, Jessica W.; Galloway, Jenna L.

    2017-01-01

    Tendons are important components of our musculoskeletal system. Injuries to these tissues are very common, resulting from occupational-related injuries, sports-related trauma, and age-related degeneration. Unfortunately, there are few treatment options, and current therapies rarely restore injured tendons to their original function. An improved understanding of the pathways regulating their development and repair would have significant impact in stimulating the formulation of regenerative-based approaches for tendon injury. The zebrafish provides an ideal system in which to perform genetic and chemical screens to identify new pathways involved in tendon biology. Until recently, there had been few descriptions of tendons and ligaments in the zebrafish and their similarity to mammalian tendon tissues. In this chapter, we describe the development of the zebrafish tendon and ligament tissues in the context of their gene expression, structure, and interactions with neighboring musculoskeletal tissues. We highlight the similarities with tendon development in higher vertebrates, showing that the craniofacial tendons and ligaments in zebrafish morphologically, molecularly, and structurally resemble mammalian tendons and ligaments from embryonic to adult stages. We detail methods for fluorescent in situ hybridization and immunohistochemistry as an assay to examine morphological changes in the zebrafish musculoskeleton. Staining assays such as these could provide the foundation for screen-based approaches to identify new regulators of tendon development, morphogenesis, and repair. These discoveries would provide new targets and pathways to study in the context of regenerative medicine-based approaches to improve tendon healing. PMID:28129848

  13. Informing Stem Cell-Based Tendon Tissue Engineering Approaches with Embryonic Tendon Development.

    PubMed

    Okech, William; Kuo, Catherine K

    Adult tendons fail to regenerate normal tissue after injury, and instead form dysfunctional scar tissue with abnormal mechanical properties. Surgical repair with grafts is the current standard to treat injuries, but faces significant limitations including pain and high rates of re-injury. To address this, we aim to regenerate new, normal tendons to replace dysfunctional tendons. A common approach to tendon tissue engineering is to design scaffolds and bioreactors based on adult tendon properties that can direct adult stem cell tenogenesis. Despite significant progress, advances have been limited due, in part, to a need for markers and potent induction cues. Our goal is to develop novel tendon tissue engineering approaches informed by embryonic tendon development. We are characterizing structure-property relationships of embryonic tendon to identify design parameters for three-dimensional scaffolds and bioreactor mechanical loading systems to direct adult stem cell tenogenesis. We will review studies in which we quantified changes in the mechanical and biochemical properties of tendon during embryonic development and elucidated specific mechanisms of functional property elaboration. We then examined the effects of these mechanical and biochemical factors on embryonic tendon cell behavior. Using custom-designed bioreactors, we also examined the effects of dynamic mechanical loading and growth factor treatment on embryonic tendon cells. Our findings have established cues to induce tenogenesis as well as metrics to evaluate differentiation. We finish by discussing how we have evaluated the tenogenic differentiation potential of adult stem cells by comparing their responses to that of embryonic tendon cells in these culture systems.

  14. Cell therapy for tendinitis, experimental and clinical report.

    PubMed

    Lacitignola, L; Crovace, A; Rossi, G; Francioso, E

    2008-09-01

    To compare cultured bone marrow mesenchymal cells (cBMSC), bone marrow mononucleated cells (BMMNCs), and placebo to repair collagenase-induced tissue damage in an equine model of experimental tendonitis, 6 Standardbred horses with no signs of previous SDF tendon injury have been recruited. Three weeks after collagenase treatment an average of either 5.5 x 10(6) cBMSCs or 122.3 x 10(6) BMMNCs, saline solution (placebo) or fibrin glue were injected intralesionally in random order. Horses were stall rested for 21 weeks, and tendon ultrasound scans performed before and during this period. Horses were euthanized and tendons harvested for histology and immunohistochemistry. Data observed in this study showed effectiveness of cBMSC and BMMNC in regenerating tendon tissue after collagenase -induced tendonitis. Both cBMSC and BMMNC transplantation resulted in qualitatively similar regeneration of tendon extracellular matrix in terms of type I/III collagen ratio, fiber orientation, and COMP expression. After this favourable results, 20 horses were recruited referred for spontaneous lesions of the flexor tendons or the suspensory ligament. Horses were treated with autologous graft of BMMNCs.After treatment the. the exercise program allowed was 8 weeks stall rest, 4 weeks hand walking, 4 weeks trotting, 4 weeks of gradually raising of exercise level then horses were gone back to race. US characteristics of lesions started to improve at T3. CSA-l, FPS and TLS were better in all patients, with an appreciable filling of lesions indicated by a decreasing of CSA-l and increasing of TLS. When horses started the exercise program T8 tendon architecture improved, demonstrated by their longitudinal alignment and length. At T6, and persistently in later follow-up, no lameness was evident by clinical examination. At time of writing 12 patients (60%) were go back to races, while other 8 (40%) are under controlled exercise program. Re-injury rate was assessed at 25%. All the owners judged good to excellent the outcome in term of athletic success.

  15. Wrist kinetics after luno-triquetral dissociation: the changes in moment arms of the flexor carpi ulnaris tendon.

    PubMed

    Tang, Jin Bo; Xie, Ren Gou; Yu, Xiao Wei; Chen, Feng

    2002-11-01

    Wrist biomechanics after luno-triquetral (LT) dissociation is important for understanding the clinical sequelae of the disease and for determining its treatment options. The LT interosseous ligament plays an important role in stabilizing the joint and damage to the ligament would be expected to significantly increase moment arms of tendon of the flexor carpi ulnaris (FCU), the principal ulnar wrist flexor. We investigated the changes in moment arms of FCU tendon after various amounts of sectioning of the ligaments proven to be associated with LT dissociation. In six fresh frozen cadaveric upper extremities, excursions of the FCU tendon were recorded simultaneously with wrist joint angulation during wrist flexion-extension and radioulnar deviation. Tendon excursions were measured in intact wrists, in wrists with sectioning of the dorsal portion of the LT interosseous ligament, in wrists with sectioning of the entire LT interosseous ligament, and finally in wrists with further sectioning of the dorsal radiotriquetral and intercarpal ligaments. Moment arms of the tendon were calculated from tendon excursions and joint motion angulations and expressed as percentage changes from those in the intact wrist. During wrist flexion-extension, moment arms of the FCU tendon after sectioning of the entire LT interosseous ligament and after sectioning of the two capsular ligaments were 112 +/- 7% and 114 +/- 8%, respectively; these values were significantly greater than those in the intact wrist. During radioulnar deviation, the moment arms were 114 +/- 11% after sectioning of the dorsal portion of the LT interosseous ligament, 134 +/- 15% after sectioning of the entire ligament, and 153 +/- 18% after sectioning of the capsular ligaments, again being significantly greater than the normal wrist. Increase in moment arms of the FCU tendon after loss of integrity of the LT interosseous ligament and dorsal capsular ligaments may contribute to clinical sequelae of LT dissociation and difficulty in treating this disorder.

  16. Genipin crosslinker releasing sutures for improving the mechanical/repair strength of damaged connective tissue.

    PubMed

    Sundararaj, Sharath; Slusarewicz, Paul; Brown, Matt; Hedman, Thomas

    2017-11-01

    The most common mode of surgical repair of ruptured tendons and ligaments involves the use of sutures for reattachment. However, there is a high incidence of rerupture and repair failure due to pulling out of the suture material from the damaged connective tissue. The main goal of this research was to achieve a localized delivery of crosslinking agent genipin (GP) from rapid-release biodegradable coatings on sutures, for strengthening the repair of ruptured connective tissue. Our hypothesis is that GP released from the suture coating will lead to exogenous crosslinking of native connective tissue resulting in beneficial effects on clinically relevant mechanical parameters such as tear resistance, tissue strength, and energy required to rupture the tissue (toughness). Sutures were successfully coated with a biodegradable polymer layer loaded with the crosslinking agent genipin, without compromising the mechanical properties of the suture. The rapid-release of genipin was achieved under both in vitro and ex vivo conditions. Exogenous crosslinking using these genipin releasing sutures was demonstrated using equine tendons. The tendons treated with genipin releasing sutures showed significant improvement in failure load, energy required for pull-out failure, and stiffness. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2199-2205, 2017. © 2016 Wiley Periodicals, Inc.

  17. What We Should Know Before Using Tissue Engineering Techniques to Repair Injured Tendons: A Developmental Biology Perspective

    PubMed Central

    Liu, Chia-Feng; Aschbacher-Smith, Lindsey; Barthelery, Nicolas J.; Dyment, Nathaniel; Butler, David

    2011-01-01

    Tendons connect muscles to bones, and serve as the transmitters of force that allow all the movements of the body. Tenocytes are the basic cellular units of tendons, and produce the collagens that form the hierarchical fiber system of the tendon. Tendon injuries are common, and difficult to repair, particularly in the case of the insertion of tendon into bone. Successful attempts at cell-based repair therapies will require an understanding of the normal development of tendon tissues, including their differentiated regions such as the fibrous mid-section and fibrocartilaginous insertion site. Many genes are known to be involved in the formation of tendon. However, their functional roles in tendon development have not been fully characterized. Tissue engineers have attempted to generate functional tendon tissue in vitro. However, a lack of knowledge of normal tendon development has hampered these efforts. Here we review studies focusing on the developmental mechanisms of tendon development, and discuss the potential applications of a molecular understanding of tendon development to the treatment of tendon injuries. PMID:21314435

  18. The PASTA Bridge: A Technique for the Arthroscopic Repair of PASTA Lesions.

    PubMed

    Hirahara, Alan M; Andersen, Wyatt J

    2017-10-01

    PASTA (partial articular supraspinatus tendon avulsion) lesions of greater than 50% thickness are usually repaired, whereas those of less than 50% thickness receive subacromial decompression and debridement. However, tears of greater than 25% thickness of the tendon result in increased strain of the adjacent, intact tendon fibers. Re-creating the tendon footprint at the greater tuberosity is the goal of a repair. Transtendon repairs have been considered the gold standard in repair but have shown varying outcomes and are technically difficult procedures. This report details the PASTA bridge-a technique for the arthroscopic, percutaneous repair of PASTA lesions. The PASTA bridge uses a spinal needle to ensure the repair includes the leading edge of the good tissue and is at the appropriate angle and area. Most procedures use a knife or trocar blindly to access the joint to place anchors, which has the potential to damage surrounding tissues and result in poor anchor and suture placement. The PASTA bridge is a safe, reliable procedure that is easily reproducible and appropriate for surgeons of all experience levels and should be strongly considered when repairing PASTA lesions.

  19. System and Method for Tensioning a Robotically Actuated Tendon

    NASA Technical Reports Server (NTRS)

    Reiland, Matthew J. (Inventor); Diftler, Myron A. (Inventor)

    2013-01-01

    A tendon tensioning system includes a tendon having a proximal end and a distal end, an actuator, and a motor controller. The actuator may include a drive screw and a motor, and may be coupled with the proximal end of the tendon and configured to apply a tension through the tendon in response to an electrical current. The motor controller may be electrically coupled with the actuator, and configured to provide an electrical current having a first amplitude to the actuator until a stall tension is achieved through the tendon; provide a pulse current to the actuator following the achievement of the stall tension, where the amplitude of the pulse current is greater than the first amplitude, and return the motor to a steady state holding current following the conclusion of the pulse current.

  20. Primary achilles tendon repair with mini-dorsolateral incision technique and accelerated rehabilitation.

    PubMed

    Hrnack, Scott A; Crates, John M; Barber, F Alan

    2012-10-01

    No consensus exists for the best primary repair of acute Achilles tendon ruptures. Problems with wound healing and nerve damage can occur. Prolonged immobilization leads to stiffness and calf atrophy. This study assesses the clinical outcome of acute Achilles tendon repairs using a mini-dorsolateral incision followed by a rapid rehabilitation program. A consecutive series of acute Achilles tendon ruptures repaired using a mini-dorsolateral incision were reviewed with a minimum 12 months follow up. Fifteen patients with an average age of 44 (range, 32 to 60) years were followed an average of 45 (range, 14 to 72) months. Two modified, buried core high strength sutures were placed in each torn end of the Achilles tendon reinforced with a running circumferential whip-stitch. Ankle Hindfoot scores, single toe raises, calf circumference, and adverse events were recorded. An accelerated postoperative rehabilitation protocol was followed. Postoperative AOFAS Ankle Hindfoot scores averaged 98.3 [39 pain; 49.6 function; 9.3 alignment]. All patients could single heel raise. Eight of 15 demonstrated atrophy with an average calf circumference loss of 1.0 cm. The only postoperative complication was one case of superficial cellulitis successfully treated with oral antibiotics. There were no sural nerve injuries, wound break down, or re-ruptures at final followup. The repair of acute Achilles tendon ruptures through a minimal lateral incision provided excellent functional outcomes, avoided complications including sural nerve injury, and allowed a return to sports between 4 to 6 months.

  1. Treatment of acute achilles tendon rupture with the panda rope bridge technique.

    PubMed

    Yin, Liangjun; Wu, Yahong; Ren, Changsong; Wang, Yizhong; Fu, Ting; Cheng, Xiangjun; Li, Ruidong; Nie, Mao; Mu, Yuan

    2018-03-01

    Although nonsurgical methods and many surgical techniques have been developed for repairing a ruptured Achilles tendon, there is no consensus on its best treatment. In this article, a novel minimally invasive technique called the Panda Rope Bridge Technique (PRBT) is described. Patient with acute Achilles tendon rupture was operated on in the prone position. The PRBT begin with making the proximal bridge anchor (Krackow sutures in the myotendinous junction), the distal bridge anchor (two suture anchors in the calcaneus bone) and the ropes (threads of the suture anchors) stretched between the anchor sites. Then a small incision was made to debride and reattach the stumps of ruptured tendon. After the surgery, no cast or splint fixation was applied. All patients performed enhanced recovery after surgery (ERAS), which included immediate ankle mobilisation from day 1, full weight-bearing walking from day 5 to 7, and gradually take part in athletic exercises from 8 weeks postoperatively. PBRT was performed in 11patients with acute Achilles tendon rupture between June 2012 and June 2015. No wound infection, fistula, skin necrosis, sural nerve damage, deep venous thrombosis or tendon re-rupture was found. One year after the surgery, all patients reported 100 AOFAS ankle-hindfoot score points and the mean ATRS was 96.6. The PRBT is a simple, effective and minimally invasive technique, with no need for immobilisation of the ankle, making possible immediate and aggressive postoperative rehabilitation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. [Tendinopathy in rheumatic diseases].

    PubMed

    Henniger, M; Rehart, S

    2017-03-01

    Involvement of tendons and tendon sheaths is frequently found in the most common inflammatory systemic diseases, rheumatoid arthritis and spondyloarthritis. In rheumatoid arthritis tendon manifestations occur as tenosynovitis, with swelling and pain of the tendons mainly on the hands and feet. In spondyloarthritis the involvement of tendons presents as enthesitis with pain and swelling directly at the attachment points of tendons to the bony structures and more commonly in the lower extremities. Pathological alterations of tendons can be normally visualized by sonography and only sometimes with magnetic resonance imaging (MRI) or scintigraphy. Furthermore, it is important for diagnostics and effective therapy to detect all joints involved by means of clinical, sonographic and radiological examination as well as laboratory parameters of inflammation, antibody serology (e.g. anti-CCP antibodies) and HLA-B27. The histopathological alterations of tendinopathy in rheumatic diseases differ from degenerative/posttraumatic tendinopathy in their expression of the changes; however, a clear differentiation of the different rheumatic inflammatory systemic diseases is histopathologically not possible. Therapeutically, systemic medication is the most important part of treatment in rheumatic diseases. Local therapeutic measures can be employed in the treatment of tenosynovitis and enthesitis. In the case of failure or lack of efficacy of the medication and conservative therapy, tenosynovectomy is performed for persistent tenosynovitis and reconstructive surgical procedures are necessary for tendon ruptures.

  3. An Intelligent Computerized Stretch Reflex Measurement System For Clinical And Investigative Neurology

    NASA Astrophysics Data System (ADS)

    Flanagan, P. M.; Chutkow, J. G.; Riggs, M. T.; Cristiano, V. D.

    1987-05-01

    We describe the design of a reliable, user-friendly preprototype system for quantifying the tendon stretch reflexes in humans and large mammals. A hand-held, instrumented reflex gun, the impactor of which contains a single force sensor, interfaces with a computer. The resulting test system can deliver sequences of reproducible stimuli at graded intensities and adjustable durations to a muscle's tendon ("tendon taps"), measure the impacting force of each tap, and record the subsequent reflex muscle contraction from the same tendon -- all automatically. The parameters of the reflex muscle contraction include latency; mechanical threshold; and peak time, peak magnitude, and settling time. The results of clinical tests presented in this paper illustrate the system's potential usefulness in detecting neurologic dysfunction affecting the tendon stretch reflexes, in documenting the course of neurologic illnesses and their response to therapy, and in clinical and laboratory neurologic research.

  4. Achilles tendon reflex measuring system

    NASA Astrophysics Data System (ADS)

    Szebeszczyk, Janina; Straszecka, Joanna

    1995-06-01

    The examination of Achilles tendon reflex is widely used as a simple, noninvasive clinical test in diagnosis and pharmacological therapy monitoring in such diseases as: hypothyroidism, hyperthyroidism, diabetic neuropathy, the lower limbs obstructive angiopathies and intermittent claudication. Presented Achilles tendon reflect measuring system is based on the piezoresistive sensor connected with the cylinder-piston system. To determinate the moment of Achilles tendon stimulation a detecting circuit was used. The outputs of the measuring system are connected to the PC-based data acquisition board. Experimental results showed that the measurement accuracy and repeatability is good enough for diagnostics and therapy monitoring purposes. A user friendly, easy-to-operate measurement system fulfills all the requirements related to recording, presentation and storing of the patients' reflexograms.

  5. Bioreactor design for tendon/ligament engineering.

    PubMed

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  6. Bioreactor Design for Tendon/Ligament Engineering

    PubMed Central

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake

    2013-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments. PMID:23072472

  7. Leukocyte-Reduced Platelet-Rich Plasma Normalizes Matrix Metabolism in Torn Human Rotator Cuff Tendons.

    PubMed

    Cross, Jessica A; Cole, Brian J; Spatny, Kaylan P; Sundman, Emily; Romeo, Anthony A; Nicholson, Greg P; Wagner, Bettina; Fortier, Lisa A

    2015-12-01

    The optimal platelet-rich plasma (PRP) for treatment of supraspinatus tendinopathy has not been determined. To evaluate the effect of low- versus high-leukocyte concentrated PRP products on catabolic and anabolic mediators of matrix metabolism in diseased rotator cuff tendons. Controlled laboratory study. Diseased supraspinatus tendons were treated with PRP made by use of 2 commercial systems: Arthrex Autologous Conditioned Plasma Double Syringe System (L(lo) PRP) and Biomet GPS III Mini Platelet Concentrate System (L(hi) PRP). Tendon explants were placed in 6-well plates and cultured in L(lo) PRP, L(hi) PRP, or control media (Dulbecco's Modified Eagle Medium + 10% fetal bovine serum) for 96 hours. Tendons were processed for hematoxylin-eosin histologic results and were scored with the modified Bonar scale. Group 1 tendons were defined as moderate tendinopathy (Bonar score <3); group 2 tendons were assessed as severely affected (Bonar score = 3). Transforming growth factor β-1 (TGFβ-1), interleukin-1β (IL-1β), interleukin-1 receptor antagonist (IL-1Ra), interleukin-6 (IL-6), interleukin-8 (IL-8), and matrix metalloproteinase-9 (MMP-9) concentrations in PRP media were measured by use of enzyme-linked immunosorbent assay after 96 hours of culture with diseased tendon. Tendon messenger RNA expression of collagen type I (COL1A1), collagen type III (COL3A1), cartilage oligomeric matrix protein (COMP), MMP-9, MMP-13, and IL-1β was measured with real-time quantitative polymerase chain reaction. Leukocytes and platelets were significantly more concentrated in L(hi) PRP compared with L(lo) PRP. Increased IL-1β was present in L(hi) PRP after culture with group 1 tendons. IL-6 was increased in L(hi) PRP after culture with group 2 tendons. Both TGFβ-1 and MMP-9 were increased in L(hi) PRP after culture with either tendon group. In L(lo) PRP cultures, IL-1Ra:IL-1β in PRP used as media and COL1A1:COL3A1 gene expression were increased for group 1 tendon cultures. Gene expression of MMP-9 and IL-1β was increased in group 2 tendons cultured in L(lo) PRP. There was no significant difference in the expression of MMP-13 or COMP in either group of tendons cultured in L(lo) PRP or L(hi) PRP. L(lo) PRP promotes normal collagen matrix synthesis and decreases cytokines associated with matrix degradation and inflammation to a greater extent than does L(hi) PRP in moderately degenerative tendons. In severely degenerative tendons, neither PRP preparation enhanced matrix synthesis. L(lo) PRP may promote healing in moderately degenerative rotator cuff tendons. © 2015 The Author(s).

  8. Coordinated Development of Muscles and Tendon-Like Structures: Early Interactions in the Drosophila Leg.

    PubMed

    Soler, Cedric; Laddada, Lilia; Jagla, Krzysztof

    2016-01-01

    The formation of the musculoskeletal system is a remarkable example of tissue assembly. In both vertebrates and invertebrates, precise connectivity between muscles and skeleton (or exoskeleton) via tendons or equivalent structures is fundamental for movement and stability of the body. The molecular and cellular processes underpinning muscle formation are well-established and significant advances have been made in understanding tendon development. However, the mechanisms contributing to proper connection between these two tissues have received less attention. Observations of coordinated development of tendons and muscles suggest these tissues may interact during the different steps in their development. There is growing evidence that, depending on animal model and muscle type, these interactions can take place from progenitor induction to the final step of the formation of the musculoskeletal system. Here, we briefly review and compare the mechanisms behind muscle and tendon interaction throughout the development of vertebrates and Drosophila before going on to discuss our recent findings on the coordinated development of muscles and tendon-like structures in Drosophila leg. By altering apodeme formation (the functional Drosophila equivalent of tendons in vertebrates) during the early steps of leg development, we affect the spatial localization of subsequent myoblasts. These findings provide the first evidence of the developmental impact of early interactions between muscle and tendon-like precursors, and confirm the appendicular Drosophila muscle system as a valuable model for studying these processes.

  9. Coordinated Development of Muscles and Tendon-Like Structures: Early Interactions in the Drosophila Leg

    PubMed Central

    Soler, Cedric; Laddada, Lilia; Jagla, Krzysztof

    2016-01-01

    The formation of the musculoskeletal system is a remarkable example of tissue assembly. In both vertebrates and invertebrates, precise connectivity between muscles and skeleton (or exoskeleton) via tendons or equivalent structures is fundamental for movement and stability of the body. The molecular and cellular processes underpinning muscle formation are well-established and significant advances have been made in understanding tendon development. However, the mechanisms contributing to proper connection between these two tissues have received less attention. Observations of coordinated development of tendons and muscles suggest these tissues may interact during the different steps in their development. There is growing evidence that, depending on animal model and muscle type, these interactions can take place from progenitor induction to the final step of the formation of the musculoskeletal system. Here, we briefly review and compare the mechanisms behind muscle and tendon interaction throughout the development of vertebrates and Drosophila before going on to discuss our recent findings on the coordinated development of muscles and tendon-like structures in Drosophila leg. By altering apodeme formation (the functional Drosophila equivalent of tendons in vertebrates) during the early steps of leg development, we affect the spatial localization of subsequent myoblasts. These findings provide the first evidence of the developmental impact of early interactions between muscle and tendon-like precursors, and confirm the appendicular Drosophila muscle system as a valuable model for studying these processes. PMID:26869938

  10. Lipids, adiposity and tendinopathy: is there a mechanistic link? Critical review

    PubMed Central

    Scott, Alex; Zwerver, Johannes; Grewal, Navi; de Sa, Agnetha; Alktebi, Thuraya; Granville, David J; Hart, David A

    2015-01-01

    Being overweight or obese is associated with an elevated risk of tendon pathology. However, for sportspeople the epidemiological data linking weight or adiposity on one hand, and risk of tendon pathology on the other, are less consistent. Indeed, the mechanistic links between diet, adiposity and tendon pathology remain largely unexamined. Recent studies have begun to examine the effects of dietary interventions on outcomes such as tendon biomechanics or pain. Oxidised low-density lipoprotein has been shown to (A) accumulate in the tendon tissues of mice that eat a fatty diet and (B) induce a pathological phenotype in human tendon cells. This paper addresses the current debate: is excessive body mass index (causing increased load and strain on tendon tissue) per se the underlying mechanism? Or do local or systemic influences of fat on tendons predispose to tendon pathology? This narrative review argues that excessive blood lipids may be an important avenue for clinical investigations. PMID:25488953

  11. Robot Arm with Tendon Connector Plate and Linear Actuator

    NASA Technical Reports Server (NTRS)

    Bridgwater, Lyndon (Inventor); Millerman, Alexander (Inventor); Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Nguyen, Vienny (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  12. Protection from Muscle Damage in the Absence of Changes in Muscle Mechanical Behavior.

    PubMed

    Hoffman, Ben W; Cresswell, Andrew G; Carroll, Timothy J; Lichtwark, Glen A

    2016-08-01

    The repeated bout effect characterizes the protective adaptation after a single bout of unaccustomed eccentric exercise that induces muscle damage. Sarcomerogenesis and increased tendon compliance have been suggested as potential mechanisms for the repeated bout effect by preventing muscle fascicles from being stretched onto the descending limb of the length-tension curve (the region where sarcomere damage is thought to occur). In this study, evidence was sought for three possible mechanical changes that would support either the sarcomerogenesis or the increased tendon compliance hypotheses: a sustained rightward shift in the fascicle length-tension relationship, reduced fascicle strain amplitude, and reduced starting fascicle length. Subjects (n = 10) walked backward downhill (5 km·h, 20% incline) on a treadmill for 30 min on two occasions separated by 7 d. Kinematic data and medial gastrocnemius fascicle lengths (ultrasonography) were recorded at 10-min intervals to compare fascicle strains between bouts. Fascicle length-torque curves from supramaximal tibial nerve stimulation were constructed before, 2 h after, and 2 d after each exercise bout. Maximum torque decrement and elevated muscle soreness were present after the first, but not the second, backward downhill walking bout signifying a protective repeated bout effect. There was no sustained rightward shift in the length-torque relationship between exercise bouts, nor decreases in fascicle strain amplitude or shortening of the starting fascicle length. Protection from a repeated bout of eccentric exercise was conferred without changes in muscle fascicle strain behavior, indicating that sarcomerogenesis and increased tendon compliance were unlikely to be responsible. As fascicle strains are relatively small in humans, we suggest that changes to connective tissue structures, such as extracellular matrix remodeling, are better able to explain the repeated bout effect observed here.

  13. Hemispheric specificity for proprioception: Postural control of standing following right or left hemisphere damage during ankle tendon vibration.

    PubMed

    Duclos, Noémie C; Maynard, Luc; Abbas, Djawad; Mesure, Serge

    2015-11-02

    Right brain damage (RBD) following stroke often causes significant postural instability. In standing (without vision), patients with RBD are more unstable than those with left brain damage (LBD). We hypothesised that this postural instability would relate to the cortical integration of proprioceptive afferents. The aim of this study was to use tendon vibration to investigate whether these changes were specific to the paretic or non-paretic limbs. 14 LBD, 12 RBD patients and 20 healthy subjects were included. Displacement of the Centre of Pressure (CoP) was recorded during quiet standing, then during 3 vibration conditions (80 Hz - 20s): paretic limb, non-paretic limb (left and right limbs for control subjects) and bilateral. Vibration was applied separately to the peroneal and Achilles tendons. Mean antero-posterior position of the CoP, variability and velocity were calculated before (4s), during and after (24s) vibration. For all parameters, the strongest perturbation was during Achilles vibrations. The Achilles non-paretic condition induced a larger backward displacement than the Achilles paretic condition. This condition caused specific behaviour on the velocity: the LBD group was perturbed at the onset of the vibrations, but gradually recovered their stability; the RBD group was significantly perturbed thereafter. After bilateral Achilles vibration, RBD patients required the most time to restore initial posture. The reduction in use of information from the paretic limb may be a central strategy to deal with risk-of-fall situations such as during Achilles vibration. The postural behaviour is profoundly altered by lesions of the right hemisphere when proprioception is perturbed. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Collagen structure of tendon relates to function.

    PubMed

    Franchi, Marco; Trirè, Alessandra; Quaranta, Marilisa; Orsini, Ester; Ottani, Victoria

    2007-03-30

    A tendon is a tough band of fibrous connective tissue that connects muscle to bone, designed to transmit forces and withstand tension during muscle contraction. Tendon may be surrounded by different structures: 1) fibrous sheaths or retinaculae; 2) reflection pulleys; 3) synovial sheaths; 4) peritendon sheaths; 5) tendon bursae. Tendons contain a) few cells, mostly represented by tenoblasts along with endothelial cells and some chondrocytes; b) proteoglycans (PGs), mainly decorin and hyaluronan, and c) collagen, mostly type I. Tendon is a good example of a high ordered extracellular matrix in which collagen molecules assemble into filamentous collagen fibrils (formed by microfibrils) which aggregate to form collagen fibers, the main structural components. It represents a multihierarchical structure as it contains collagen molecules arranged in fibrils then grouped in fibril bundles, fascicles and fiber bundles that are almost parallel to the long axis of the tendon, named as primary, secondary and tertiary bundles. Collagen fibrils in tendons show prevalently large diameter, a D-period of about 67 nm and appear built of collagen molecules lying at a slight angle (< 5 degrees). Under polarized light microscopy the collagen fiber bundles appear crimped with alternative dark and light transverse bands. In recent studies tendon crimps observed via SEM and TEM show that the single collagen fibrils suddenly changing their direction contain knots. These knots of collagen fibrils inside each tendon crimp have been termed "fibrillar crimps", and even if they show different aspects they all may fulfil the same functional role. As integral component of musculoskeletal system, the tendon acts to transmit muscle forces to the skeletal system. There is no complete understanding of the mechanisms in transmitting/absorbing tensional forces within the tendon; however it seems likely that a flattening of tendon crimps may occur at a first stage of tendon stretching. Increasing stretching, other transmission mechanisms such as an interfibrillar coupling via PGs linkages and a molecular gliding within the fibrils structure may be involved.

  15. Novel image analysis methods for quantification of in situ 3-D tendon cell and matrix strain.

    PubMed

    Fung, Ashley K; Paredes, J J; Andarawis-Puri, Nelly

    2018-01-23

    Macroscopic tendon loads modulate the cellular microenvironment leading to biological outcomes such as degeneration or repair. Previous studies have shown that damage accumulation and the phases of tendon healing are marked by significant changes in the extracellular matrix, but it remains unknown how mechanical forces of the extracellular matrix are translated to mechanotransduction pathways that ultimately drive the biological response. Our overarching hypothesis is that the unique relationship between extracellular matrix strain and cell deformation will dictate biological outcomes, prompting the need for quantitative methods to characterize the local strain environment. While 2-D methods have successfully calculated matrix strain and cell deformation, 3-D methods are necessary to capture the increased complexity that can arise due to high levels of anisotropy and out-of-plane motion, particularly in the disorganized, highly cellular, injured state. In this study, we validated the use of digital volume correlation methods to quantify 3-D matrix strain using images of naïve tendon cells, the collagen fiber matrix, and injured tendon cells. Additionally, naïve tendon cell images were used to develop novel methods for 3-D cell deformation and 3-D cell-matrix strain, which is defined as a quantitative measure of the relationship between matrix strain and cell deformation. The results support that these methods can be used to detect strains with high accuracy and can be further extended to an in vivo setting for observing temporal changes in cell and matrix mechanics during degeneration and healing. Copyright © 2017. Published by Elsevier Ltd.

  16. Phenytoin accelerates tendon healing in a rat model of Achilles tendon rupture.

    PubMed

    Hajipour, B; Navali, A M; Mohammad, S Ali; Mousavi, G; Akbari, M Gahvechi; Miyandoab, T Maleki; Roshangar, L; Saleh, B Mohammadi; Kermani, T Asvadi; Laleh, F Moutab; Ghabili, M

    2016-01-01

    Tendons are vulnerable to various types of acute or chronic injures. Different methods have been investigated to achieve better healing. Phenytoin is a drug which could stimulate fibroblasts to produce collagen. This experimental study was performed to assess the effect of phenytoin on tendon healing in a rat model of tendon rupture. Thirty healthy rats were divided into 3 groups, 1) Sham group; 2) Tendon rupture; 3) Tendon rupture+phenytoin (100 mg/kg intraperitoneally) for 21 days. On 21st day after tendon injury, the rats were anesthetized and tendon tissue was sampled for studying by light and electron microscopy. Qualitative and quantitative microscopic comparisons of the repair tissues of both groups were made on the 21st day. The results obtained from light and electron microscopy studies showed that tendon tissue healing was significantly better in phenytoin group compared to the control group (p < 0.05). Systemic administration of phenytoin may have a positive effect on tendon healing by increasing fibroblast quantity, fibrillar collagen synthesis, vascularity, and suppressing inflammation (Tab. 2, Ref. 25).

  17. An analysis of the deployment of a pumpkin balloon on mars

    NASA Astrophysics Data System (ADS)

    Rand, J.; Phillips, M.

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, which produces stress resultants determined by the volume of the system, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. The application of this technology to very large systems is currently being demonstrated by NASA's Ultra Long Duration Balloon (ULDB) Program. However, this type of balloon has certain features that may be exploited to produce a system far more robust than a comparable sphere during deployment, inflation, and operation for long periods of time. When this concept is applied to a system designed to carry two kilograms in the atmosphere of Mars, the resulting balloon is small enough to alter the construction techniques and produce an envelope which is free of tucks and folds which may cause uncontrolled stress concentrations. A technique has been demonstrated where high strength tendons may be pretensioned prior to installation along the centerline of each gore. Since this position is the shortest distance between the apex and nadir of the balloon, the tendons will automatically resist the forces caused by deployment and inflation and thereby protect the thin film gas barrier from damage. A suitable balloon has been designed for this type of mission using five-micron Mylar Type C film for the gas barrier and P O braided cables for the meridionalB load carrying members. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a ten-kilogram system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred to the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon, altering the pressure distribution and shape. As a result, stresses are seen to increase beyond the design margin of safety, requiring the balloon to be redesigned. In addition, several scale models of this balloon were dynamically deployed in the laboratory to demonstrate that the deployment forces are indeed carried by the tendons

  18. Prenatal methylmercury poisoning: clinical observations over five years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amin-Zaki, L.; Majeed, M.A.; Elhassani, S.B.

    1979-02-01

    Thirty-two infants prenatally exposed to methylmercury and their mothers were examined over a five-year period after the Iraqi methylmercury epidemic. Severity of poisoning in mothers was related to the peak mercury concentration in their hair and in the infants to the maximum concentration in maternal hair during pregnancy. In nine cases of cerebral palsy, methylmercury exposure occurred only during the last trimester. All infants except three (two were orphaned soon after birth and one was bottle-fed) were exposed postnatally via suckling. Whereas the mother's symptoms usually improved, the damage to the fetal nervous system appears to be permanent. Milder casesmore » previously not identified in other studies are reported. The syndrome consists of varying degrees of developmental retardation in addition to exaggerated tendon reflexes and the pathologic extensor plantar reflex (minimal brain damage syndrome).« less

  19. Mechanical Control of Myotendinous Junction Formation and Tendon Differentiation during Development.

    PubMed

    Valdivia, Mauricio; Vega-Macaya, Franco; Olguín, Patricio

    2017-01-01

    The development of the musculoskeletal system is a great model to study the interplay between chemical and mechanical inter-tissue signaling in cell adhesion, tissue morphogenesis and differentiation. In both vertebrates and invertebrates (e.g., Drosophila melanogaster ) the formation of muscle-tendon interaction generates mechanical forces which are required for myotendinous junction maturation and tissue differentiation. In addition, these forces must be withstood by muscles and tendons in order to prevent detachment from each other, deformation or even losing their integrity. Extracellular matrix remodeling at the myotendinous junction is key to resist mechanical load generated by muscle contraction. Recent evidences in vertebrates indicate that mechanical forces generated during junction formation regulate chemical signaling leading to extracellular matrix remodeling, however, the mechanotransduction mechanisms associated to this response remains elusive. In addition to extracellular matrix remodeling, the ability of Drosophila tendon-cells to bear mechanical load depends on rearrangement of tendon cell cytoskeleton, thus studying the molecular mechanisms involved in this process is critical to understand the contribution of mechanical forces to the development of the musculoskeletal system. Here, we review recent findings regarding the role of chemical and mechanical signaling in myotendinous junction formation and tendon differentiation, and discuss molecular mechanisms of mechanotransduction that may allow tendon cells to withstand mechanical load during development of the musculoskeletal system.

  20. Design, analysis and control of a novel tendon-driven magnetic resonance-guided robotic system for minimally invasive breast surgery.

    PubMed

    Jiang, Shan; Lou, Jinlong; Yang, Zhiyong; Dai, Jiansheng; Yu, Yan

    2015-09-01

    Biopsy and brachytherapy for small core breast cancer are always difficult medical problems in the field of cancer treatment. This research mainly develops a magnetic resonance imaging-guided high-precision robotic system for breast puncture treatment. First, a 5-degree-of-freedom tendon-based surgical robotic system is introduced in detail. What follows are the kinematic analysis and dynamical modeling of the robotic system, where a mathematic dynamic model is established using the Lagrange method and a lumped parameter tendon model is used to identify the nonlinear gain of the tendon-sheath transmission system. Based on the dynamical models, an adaptive proportional-integral-derivative controller with friction compensation is proposed for accurate position control. Through simulations using different sinusoidal input signals, we observe that the sinusoidal tracking error at 1/2π Hz is 0.41 mm. Finally, the experiments on tendon-sheath transmission and needle insertion performance are conducted, which show that the insertion precision is 0.68 mm in laboratory environment. © IMechE 2015.

  1. The anatomical and imaging study of pes anserinus and its clinical application

    PubMed Central

    Zhong, Sheng; Wu, Bo; Wang, Miao; Wang, Xiaohong; Yan, Qi; Fan, Xingyu; Hu, Yanmei; Han, Yingying; Li, Youqiong

    2018-01-01

    Abstract Background: The pes anserinus was an important graft choice for anterior cruciate ligament (ACL) reconstruction. The infrapatellar branch of the saphenous nerve (IPBSN) might be damaged in this surgery. This study aimed to provide anatomic and ultrasonic measurement data of pes anserinus and superficial nerves. Methods: Eighty lower limb specimens of forty adult cadavers were dissected. The length, width, thickness, and the position of the tibial attachment of pes anserinus tendons were anthropometric measured, as well as the distance between the infrapatellar branch of the saphenous nerve and the pes anserinus. Sixty healthy adult participants were enrolled for ultrasonic research. The length, width, thickness of pes anserinus was also measured and the saphenous nerve was also assessed. Results: Anatomic results showed that there were 3 types of pes anserinus, the infrapatellar branch of the saphenous nerve (IPBSN) was almost paralleled to the upper edge of the pes anserinus tendon, and the average of distance between them was about 0.95 cm. The length of semitendinosus and gracilis tendons were 146.49 ± 12.83 mm and 124.62 ± 8.86 mm, the width of sartorius tendon was 25.58 ± 4.65 mm, wider than other tendons. The classification of pes anserinus tendons and the saphenous nerves could be identified in ultrasonic image. The length of semitendinosus and gracilis tendons were 151.35 ± 9.65 mm and 120.86 ± 8.99 mm, the width of sartorius tendon was 22.84 ± 3.83 mm. And there was no significance difference between anatomic and ultrasonic measurement (P > .05). Conclusion: The morphology of pes anserinus and its peripheral structures could be identified and measured precisely by ultrasound device, a presurgical ultrasonic examination was recommended. The arrangement of pes anserinus tendons was classified into 3 types according to our results. The incision should be performed medial to tibial eminence 1.5 cm and under the tibial tubercle level 2 to 3 cm, an oblique incision formed an angle of 50° with tibial transection was recommend, which was parallel to the direction of pes anserinus tendon. PMID:29642176

  2. Evidence of accumulated stress in Achilles and anterior knee tendons in elite badminton players.

    PubMed

    Boesen, Anders Ploug; Boesen, Morten Ilum; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren; Langberg, Henning

    2011-01-01

    Tendon-related injuries are a major problem, but the aetiology of tendinopathies is unknown. In tendinopathies as well as during unaccustomed loading, intra-tendinous flow can be detected indicating that extensive loading can provoke intra-tendinous flow. The aim of present study is to evaluate the vascular response as indicated by colour Doppler (CD) activity in both the Achilles and patella tendon after loading during high-level badminton matches. The Achilles tendon was subdivided into a mid-tendon, pre-insertional, and insertional region and the anterior knee tendons into a quadriceps-, patella- and tuberositas region. Intra-tendinous flow was measured using both a semi-quantitative grading system (CD grading) and a quantitative scoring system (CF) on colour Doppler. Intra-tendinous flow in the Achilles and anterior knee tendons was examined in fourteen single players before tournament and after 1st and 2nd match, respectively on both the dominant and non-dominant side. All players had abnormal intra-tendinous flow (Colour Doppler ≥ grade 2) in at least one tendon in at least one scan during the tournament. At baseline, only two of the 14 players had normal flow in all the tendons examined. After 1st match, tendencies to higher intra-tendinous flow were observed in both the dominant patella tendon and non-dominant quadriceps tendon (P-values n.s.). After 2nd match, intra-tendinous flow was significant increased in the dominant patella tendon (P = 0.009). In all other locations, there was a trend towards a stepwise increase in intra-tendinous flow. The preliminary results indicate that high amount of intra-tendinous flow was found in elite badminton players at baseline and was increased after repetitive loading, especially in the patella tendon (dominant leg). The colour Doppler measurement can be used to determine changes in intra-tendinous flow after repetitive loading.

  3. Doppler ultrasound-based measurement of tendon velocity and displacement for application toward detecting user-intended motion.

    PubMed

    Stegman, Kelly J; Park, Edward J; Dechev, Nikolai

    2012-07-01

    The motivation of this research is to non-invasively monitor the wrist tendon's displacement and velocity, for purposes of controlling a prosthetic device. This feasibility study aims to determine if the proposed technique using Doppler ultrasound is able to accurately estimate the tendon's instantaneous velocity and displacement. This study is conducted with a tendon mimicking experiment consisting of two different materials: a commercial ultrasound scanner, and a reference linear motion stage set-up. Audio-based output signals are acquired from the ultrasound scanner, and are processed with our proposed Fourier technique to obtain the tendon's velocity and displacement estimates. We then compare our estimates to an external reference system, and also to the ultrasound scanner's own estimates based on its proprietary software. The proposed tendon motion estimation method has been shown to be repeatable, effective and accurate in comparison to the external reference system, and is generally more accurate than the scanner's own estimates. After establishing this feasibility study, future testing will include cadaver-based studies to test the technique on the human arm tendon anatomy, and later on live human test subjects in order to further refine the proposed method for the novel purpose of detecting user-intended tendon motion for controlling wearable prosthetic devices.

  4. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    NASA Astrophysics Data System (ADS)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  5. Human tendon behaviour and adaptation, in vivo

    PubMed Central

    Magnusson, S Peter; Narici, Marco V; Maganaris, Constantinos N; Kjaer, Michael

    2008-01-01

    Tendon properties contribute to the complex interaction of the central nervous system, muscle–tendon unit and bony structures to produce joint movement. Until recently limited information on human tendon behaviour in vivo was available; however, novel methodological advancements have enabled new insights to be gained in this area. The present review summarizes the progress made with respect to human tendon and aponeurosis function in vivo, and how tendons adapt to ageing, loading and unloading conditions. During low tensile loading or with passive lengthening not only the muscle is elongated, but also the tendon undergoes significant length changes, which may have implications for reflex responses. During active loading, the length change of the tendon far exceeds that of the aponeurosis, indicating that the aponeurosis may more effectively transfer force onto the tendon, which lengthens and stores elastic energy subsequently released during unloading, in a spring-like manner. In fact, data recently obtained in vivo confirm that, during walking, the human Achilles tendon provides elastic strain energy that can decrease the energy cost of locomotion. Also, new experimental evidence shows that, contrary to earlier beliefs, the metabolic activity in human tendon is remarkably high and this affords the tendon the ability to adapt to changing demands. With ageing and disuse there is a reduction in tendon stiffness, which can be mitigated with resistance exercises. Such adaptations seem advantageous for maintaining movement rapidity, reducing tendon stress and risk of injury, and possibly, for enabling muscles to operate closer to the optimum region of the length–tension relationship. PMID:17855761

  6. Ultrasound Characteristics of the Achilles Tendon in Tophaceous Gout: A Comparison with Age- and Sex-matched Controls.

    PubMed

    Carroll, Matthew; Dalbeth, Nicola; Allen, Bruce; Stewart, Sarah; House, Tony; Boocock, Mark; Frampton, Christopher; Rome, Keith

    2017-10-01

    To investigate the frequency and distribution of characteristics of the Achilles tendon (AT) in people with tophaceous gout using musculoskeletal ultrasound (US). Twenty-four participants with tophaceous gout and 24 age- and sex-matched controls without gout or other arthritis were recruited. All participants underwent a greyscale and power Doppler US examination. The AT was divided into 3 anatomical zones (insertion, pre-insertional, and proximal to the mid-section). The following US characteristics were assessed: tophus, tendon echogenicity, tendon vascularity, tendon morphology, entheseal characteristics, bursal morphology, and calcaneal bone profile. The majority of the participants with tophaceous gout were middle-aged men (n = 22, 92%) predominately of European ethnicity (n = 14, 58%). Tophus deposition was observed in 73% (n = 35) of tendons in those with gout and in none of the controls (p < 0.01). Intratendinous hyperechoic spots (p < 0.01) and intratendinous power Doppler signal (p < 0.01) were more frequent in participants with gout compared to controls. High prevalence of entheseal calcifications, calcaneal bone cortex irregularities, and calcaneal enthesophytes were observed in both gout participants and controls, without differences between groups. Intratendinous structural damage was rare. Hyperechoic spots were significantly more common at the insertion compared to the zone proximal to the mid-section (p < 0.01), but between-zone differences were not observed for other features. US features of urate deposition, tophus, and vascularization are present throughout the AT in patients with tophaceous gout. Despite crystal deposition, intratendinous structural changes are infrequent. Many characteristics observed in the AT in people with tophaceous gout, particularly at the calcaneal enthesis, are not disease-specific.

  7. A systems biology approach to defining regulatory mechanisms for cartilage and tendon cell phenotypes.

    PubMed

    Mueller, A J; Tew, S R; Vasieva, O; Clegg, P D; Canty-Laird, E G

    2016-09-27

    Phenotypic plasticity of adult somatic cells has provided emerging avenues for the development of regenerative therapeutics. In musculoskeletal biology the mechanistic regulatory networks of genes governing the phenotypic plasticity of cartilage and tendon cells has not been considered systematically. Additionally, a lack of strategies to effectively reproduce in vitro functional models of cartilage and tendon is retarding progress in this field. De- and redifferentiation represent phenotypic transitions that may contribute to loss of function in ageing musculoskeletal tissues. Applying a systems biology network analysis approach to global gene expression profiles derived from common in vitro culture systems (monolayer and three-dimensional cultures) this study demonstrates common regulatory mechanisms governing de- and redifferentiation transitions in cartilage and tendon cells. Furthermore, evidence of convergence of gene expression profiles during monolayer expansion of cartilage and tendon cells, and the expression of key developmental markers, challenges the physiological relevance of this culture system. The study also suggests that oxidative stress and PI3K signalling pathways are key modulators of in vitro phenotypes for cells of musculoskeletal origin.

  8. Evolution of the Achilles tendon: The athlete's Achilles heel?

    PubMed

    Malvankar, S; Khan, W S

    2011-12-01

    The Achilles tendon is believed to have first developed two million years ago enabling humans to run twice as fast. However if the Achilles tendon is so important in terms of evolution, then why is this tendon so prone to injury - especially for those more active like athletes. The Achilles tendon had an integral role in evolving apes from a herbivorous diet to early humans who started hunting for food over longer distances, resulting in bipedal locomotion. Evolutionary advantages of the Achilles tendon includes it being the strongest tendon in the body, having an energy-saving mechanism for fast locomotion, allows humans to jump and run, and additionally is a spring and shock absorber during gait. Considering these benefits it is therefore not surprising that studies have shown athletes have thicker Achilles tendons than subjects who are less active. However, contradictory to these findings that show the importance of the Achilles tendon for athletes, it is well known that obtaining an Achilles tendon injury for an athlete can be career-altering. A disadvantage of the Achilles tendon is that the aetiology of its pathology is complicated. Achilles tendon ruptures are believed to be caused by overloading the tensed tendon, like during sports. However studies have also shown athlete Achilles tendon ruptures to have degenerative changes in the tendon. Other flaws of the Achilles tendon are its non-uniform vascularity and incomplete repair system which may suggest the Achilles tendon is on the edge of evolution. Research has shown that there is a genetic influence on the predisposition a person has towards Achilles tendon injuries. So if this tendon is here to stay in our anatomy, and it probably is due to the slow rate of evolution in humans, research in genetic modification could be used to decrease athletes' predisposition to Achilles tendinopathy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Effects of exercise on tenocyte cellularity and tenocyte nuclear morphology in immature and mature equine digital tendons.

    PubMed

    Stanley, R L; Goodship, A E; Edwards, B; Firth, E C; Patterson-Kane, J C

    2008-03-01

    The injury-prone, energy-storing equine superficial digital flexor tendon (SDFT) of the mature performance horse has a limited ability to respond to exercise in contrast with the noninjury-prone, anatomically opposing common digital extensor tendon (CDET). Previous studies have indicated low levels of cellular activity in the mature SDFT, but in foal tendons the tenocytes may still have the ability to adapt positively to increased exercise. To measure tenocyte densities and types in histological sections from the SDFT and CDET of horses from controlled long-term, short-term and foal exercise studies. Specimens were collected from mid-metacarpal segments of the CDET and SDFT for each horse and processed for histology; central and peripheral regions of the SDFT cross-section were analysed separately (SDFTc, SDFTp). Tenocyte nuclei were counted in a total area of 1.59 mm(2) for each tendon region in each horse. Each nucleus was classified as type 1 (elongate and thin), type 2 (ovoid and plump) or type 3 (chondrocyte-like); type 1 cells are proposed to be less synthetically active than type 2 cells. No significant differences were noted between exercise and control groups in any of the studies, with the exception of an exercise-related reduction in the proportion of type 1 tenocytes for all tendons combined in the long-term study. There were tendon- and site-specific differences in tenocyte densities and proportions of type 1 and 2 cells in all 3 studies. There was no indication that exercise increased tenocyte density or proportions of the (theoretically) more active type 2 cells in immature horses (short-term and foal studies), perhaps because the training regimens did not achieve certain threshold strain levels. In the foal study these findings can still be interpreted positively as evidence that the training regimen did not induce subclinical damage.

  10. Sonographically Guided Plantaris Tendon Release: A Cadaveric Validation Study.

    PubMed

    Smith, Jay; Alfredson, Håkan; Masci, Lorenzo; Sellon, Jacob L; Woods, Charonn D

    2018-06-13

    The plantaris tendon (PT) has been implicated in the pathogenesis of symptoms in a subset of patients with Achilles region pain syndromes and has been traditionally managed via open surgical resection. Although the PT can be visualized on ultrasound, a minimally invasive technique for sonographically guided PT release has not been formally described. To validate a technique to perform sonographically guided PT release in an unembalmed cadaveric model. Prospective, cadaveric laboratory investigation. Procedural skills laboratory in a tertiary medical center. Twenty unembalmed cadaveric knee-ankle-foot specimens (10 right, 10 left; 6 male, 10 female) from 16 donors ages 55-96 years (mean 82.6 years) with BMI's of 14.1 to 33.2 kg/m 2 (mean 23.3 kg/m 2 ). Following simulated local anesthesia and sonographically guided hydrodissection of the plantaris tendon-Achilles tendon interval, a single experienced operator performed sonographically guided PT release on each specimen using an in-plane, lateral to medial approach, a commercially available, disposable 3.0 mm hook knife, and either a 17-5 MHz or 15-7 MHz linear array transducer. Each specimen was subsequently dissected to assess for PT release and iatrogenic injury. Status of the PT, Achilles tendon, and regional neurovascular structures as determined by dissection. All 20 PT releases were completed in a single attempt through a 3-5 mm incision. Dissection confirmed complete PT release in all specimens without damage to the adjacent Achilles tendon or regional neurovascular structures. Sonographically guided PT release is technically feasible and can be performed while avoiding injury to the Achilles tendon and regional neurovascular structures. Additional research is warranted to further define the role of sonographically guided PT release in patients with suspected PT-mediated Achilles region pain syndromes. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. Application of Computed Tomography Processed by Picture Archiving and Communication Systems in the Diagnosis of Acute Achilles Tendon Rupture

    PubMed Central

    Tian, Jing; Xie, Bing; Zhang, Hao

    2016-01-01

    The applications of CT examination in the diagnosis of the acute Achilles tendon rupture (AATR) were investigated. A total of 36 patients with suspected acute Achilles tendon rupture were tested using physical examination, ultrasound, and 3DCT scanning, respectively. Then, surgery was performed for the patients who showed positive result in at least two of the three tests for AATR. 3DVR, MPR, and the other CT scan image processing and diagnosis were conducted in PACS (picture archiving and communication system). PACS was also used to measure the length of distal broken ends of the Achilles tendon (AT) to tendon calcaneal insertion. Our study indicated that CT has the highest accuracy in diagnosis of acute Achilles tendon complete rupture. The length measurement is matched between PACS and those actually measured in operation. CT not only demonstrates more details directly in three dimensions especially with the rupture involved calcaneal insertion flap but also locates the rupture region for percutaneous suture by measuring the length of distal stump in PACS without the effect of the position of ankle. The accuracy of CT diagnosis for Achilles tendon partial rupture is yet to be studied. PMID:28078295

  12. Robust Operation of Tendon-Driven Robot Fingers Using Force and Position-Based Control Laws

    NASA Technical Reports Server (NTRS)

    Hargrave, Brian (Inventor); Abdallah, Muhammad E (Inventor); Reiland, Matthew J (Inventor); Diftler, Myron A (Inventor); Strawser, Philip A (Inventor); Platt, Jr., Robert J. (Inventor); Ihrke, Chris A. (Inventor)

    2013-01-01

    A robotic system includes a tendon-driven finger and a control system. The system controls the finger via a force-based control law when a tension sensor is available, and via a position-based control law when a sensor is not available. Multiple tendons may each have a corresponding sensor. The system selectively injects a compliance value into the position-based control law when only some sensors are available. A control system includes a host machine and a non-transitory computer-readable medium having a control process, which is executed by the host machine to control the finger via the force- or position-based control law. A method for controlling the finger includes determining the availability of a tension sensor(s), and selectively controlling the finger, using the control system, via the force or position-based control law. The position control law allows the control system to resist disturbances while nominally maintaining the initial state of internal tendon tensions.

  13. Specific injuries induced by the practice of trampoline, tumbling and acrobatic gymnastics.

    PubMed

    Grapton, Xavier; Lion, Alexis; Gauchard, Gérome C; Barrault, Denys; Perrin, Philippe P

    2013-02-01

    The recreational and competitive practice of acrobatic sports, that is, trampoline, tumbling and acrobatic gymnastics (ACRO), is growing rapidly around the world. Many studies described the injuries affecting young artistic gymnasts, but only few concerned acrobatic sports. During a 5-year period, 357 traumatic events were collected in young acrobats practicing trampoline, tumbling or ACRO. Accident characteristics, level of expertise and training, injury location (upper limb, spine and lower limb), type of tissue injured (bone, cartilage, muscle, ligament and tendon) and provoking factors (intrinsic/behavioural and extrinsic) were investigated. Acrobats of national and international levels were mostly injured. Injuries occurring in acrobatic sports concerned predominantly the lower limbs and concerned in this body part mainly damages to ligaments. Forearm and knee injuries were preferentially related to trampoline. Ankle injuries were preferentially related to tumbling. Wrist injuries were preferentially related to ACRO. Upper limb bone damage and upper limb tendon damage were preferentially related to trampoline and ACRO, respectively. Intrinsic/behavioural factors were the main injury determinant in the three acrobatic sports. The main injuries in acrobatic sports (i.e. lower limbs) are similar to those observed in artistic gymnastics. Specific injuries may result from falls and incomplete and/or erroneous figure's landing and may also depend to the type of the landing surface. II.

  14. Neuronal regulation of tendon homoeostasis

    PubMed Central

    Ackermann, Paul W

    2013-01-01

    The regulation of tendon homoeostasis, including adaptation to loading, is still not fully understood. Accumulating data, however, demonstrates that in addition to afferent (sensory) functions, the nervous system, via efferent pathways which are associated with through specific neuronal mediators plays an active role in regulating pain, inflammation and tendon homeostasis. This neuronal regulation of intact-, healing- and tendinopathic tendons has been shown to be mediated by three major groups of molecules including opioid, autonomic and excitatory glutamatergic neuroregulators. In intact healthy tendons the neuromediators are found in the surrounding structures: paratenon, endotenon and epitenon, whereas the proper tendon itself is practically devoid of neurovascular supply. This neuroanatomy reflects that normal tendon homoeostasis is regulated from the tendon surroundings. After injury and during tendon repair, however, there is extensive nerve ingrowth into the tendon proper, followed by a time-dependent emergence of sensory, autonomic and glutamatergic mediators, which amplify and fine-tune inflammation and regulate tendon regeneration. In tendinopathic condition, excessive and protracted presence of sensory and glutamatergic neuromediators has been identified, suggesting involvement in inflammatory, nociceptive and hypertrophic (degenerative) tissue responses. Under experimental and clinical conditions of impaired (e.g. diabetes) as well as excessive (e.g. tendinopathy) neuromediator release, dysfunctional tendon homoeostasis develops resulting in chronic pain and gradual degeneration. Thus there is a prospect that in the future pharmacotherapy and tissue engineering approaches targeting neuronal mediators and their receptors may prove to be effective therapies for painful, degenerative and traumatic tendon disorders. PMID:23718724

  15. Molecular level detection and localization of mechanical damage in collagen enabled by collagen hybridizing peptides.

    PubMed

    Zitnay, Jared L; Li, Yang; Qin, Zhao; San, Boi Hoa; Depalle, Baptiste; Reese, Shawn P; Buehler, Markus J; Yu, S Michael; Weiss, Jeffrey A

    2017-03-22

    Mechanical injury to connective tissue causes changes in collagen structure and material behaviour, but the role and mechanisms of molecular damage have not been established. In the case of mechanical subfailure damage, no apparent macroscale damage can be detected, yet this damage initiates and potentiates in pathological processes. Here, we utilize collagen hybridizing peptide (CHP), which binds unfolded collagen by triple helix formation, to detect molecular level subfailure damage to collagen in mechanically stretched rat tail tendon fascicle. Our results directly reveal that collagen triple helix unfolding occurs during tensile loading of collagenous tissues and thus is an important damage mechanism. Steered molecular dynamics simulations suggest that a likely mechanism for triple helix unfolding is intermolecular shearing of collagen α-chains. Our results elucidate a probable molecular failure mechanism associated with subfailure injuries, and demonstrate the potential of CHP targeting for diagnosis, treatment and monitoring of tissue disease and injury.

  16. Muscle response to leg lengthening during distraction osteogenesis.

    PubMed

    Thorey, Fritz; Bruenger, Jens; Windhagen, Henning; Witte, Frank

    2009-04-01

    Continuous lengthening of intact muscles during distraction osteogenesis leads to an increase of sarcomeres and enhances the regeneration of tendons and blood vessels. A high distraction rate leads to an excessive leg and muscle lengthening and might cause damages of muscle fibers with fibrosis, necrosis, and muscle weakness. Complications like muscle contractures or atrophy after postoperative immobilization emphazize the importance of muscles and their function in the clinical outcome. In an animal model of distraction osteogenesis, 18 sheep were operated with an external fixator followed by 4 days latency, 21 days distraction (1.25 mm per day) and 51 days consolidation. The anatomical location (gastrocnemius, peroneus tertius, and first flexor digitorum longus muscle), dimension and occurrence of muscular defects were characterized histologically. The callus formation and leg axis was monitored by weekly X-rays. Additionally, serum creatine kinase was analyzed during a distraction and consolidation period. Significant signs of muscle lesions in all three observed muscles can be found postoperatively, whereas normal callus formation and regular leg axis was observed radiologically. The peroneus tertius and first flexor digitorum longus muscles were found to have significantly more signs of fibrosis, inflammatory, and necrosis. Creatine kinase showed two peaks: 4 and 39 days postoperative as an indication of muscle damage and regeneration. The study implicates that muscle damages should be considered when a long-distance distraction osteogenesis is planned. The surgeon should consider these muscle responses and individually discuss a two-stage treatment or additional muscle tendon releases to minimize the risk of muscle damages.

  17. Torque Control of Underactuated Tendon-driven Robotic Fingers

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Wampler, Charles W. (Inventor); Abdallah, Muhammad E. (Inventor); Reiland, Matthew J. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Platt, Robert (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  18. Non-destructive testing (NDT) of a segmental concrete bridge scheduled for demolition, with a focus on condition assessment and corrosion detection of internal tendons.

    DOT National Transportation Integrated Search

    2017-05-01

    The service life and durability of prestressed concrete in bridges are vulnerable to corrosion damages due to many factors such as construction, material, and environment. To ensure public safety, it is important to inspect these structures and to de...

  19. Irxl1 mutant mice show reduced tendon differentiation and no patterning defects in musculoskeletal system development.

    PubMed

    Kimura, Wataru; Machii, Masashi; Xue, XiaoDong; Sultana, Nishat; Hikosaka, Keisuke; Sharkar, Mohammad T K; Uezato, Tadayoshi; Matsuda, Masashi; Koseki, Haruhiko; Miura, Naoyuki

    2011-01-01

    Irxl1 (Iroquois-related homeobox like-1) is a newly identified three amino-acid loop extension (TALE) homeobox gene, which is expressed in various mesoderm-derived tissues, particularly in the progenitors of the musculoskeletal system. To analyze the roles of Irxl1 during embryonic development, we generated mice carrying a null allele of Irxl1. Mice homozygous for the targeted allele were viable, fertile, and showed reduced tendon differentiation. Skeletal morphology and skeletal muscle weight in Irxl1-knockout mice appeared normal. Expression patterns of several marker genes for cartilage, tendon, and muscle progenitors in homozygous mutant embryos were unchanged. These results suggest that Irxl1 is required for the tendon differentiation but dispensable for the patterning of the musculoskeletal system in development. Copyright © 2010 Wiley-Liss, Inc.

  20. Response of tibialis anterior tendon to a chronic exposure of stretch-shortening cycles: age effects

    PubMed Central

    Ensey, James S; Hollander, Melinda S; Wu, John Z; Kashon, Michael L; Baker, Brent B; Cutlip, Robert G

    2009-01-01

    Background The purpose of the current study was to investigate the effects of aging on tendon response to repetitive exposures of stretch-shortening cycles (SSC's). Methods The left hind limb from young (3 mo, N = 4) and old (30 mo, N = 9) male Fisher 344 × Brown Norway rats were exposed to 80 maximal SSCs (60 deg/s, 50 deg range of motion) 3x/week for 4.5 weeks in vivo. After the last exposure, tendons from the tibialis anterior muscle were isolated, stored at -80°C, and then tested using a micro-mechanical testing machine. Deformation of each tendon was evaluated using both relative grip-to-grip displacements and reference marks via a video system. Results At failure, the young control tendons had higher strain magnitude than the young exposed (p < 0.01) and the old control tendons (p < .0001). Total load at inflection was affected by age only (p < 0.01). Old exposed and control tendons exhibited significantly higher loads at the inflection point than their young counterparts (p < 0.05 for both comparisons). At failure, the old exposed tendons carried higher loads than the young exposed tendons (p < 0.05). Stiffness was affected by age only at failure where the old tendons exhibited higher stiffness in both exposed and control tendons than their young counterparts (p < 0.05 and p < 0.01, respectively). Conclusion The chronic protocol enhanced the elastic stiffness of young tendon and the loads in both the young and old tendons. The old exposed tendons were found to exhibit higher load capacity than their younger counterparts, which differed from our initial hypothesis. PMID:19563638

  1. Conduction block in the peripheral nervous system in experimental allergic encephalomyelitis

    NASA Astrophysics Data System (ADS)

    Pender, M. P.; Sears, T. A.

    1982-04-01

    Experimental allergic encephalomyelitis (EAE) has been widely studied as a model of multiple sclerosis, a central nervous system (CNS) disease of unknown aetiology. The clinical features of both EAE and multiple sclerosis provide the only guide to the progress and severity of these diseases, and are used to assess the response to treatment. In such comparisons the clinical features of EAE are assumed to be due to lesions in the CNS, but in this disease there is also histological evidence of damage to the peripheral nervous system1-8. However, the functional consequences of such peripheral lesions have been entirely ignored. To examine this we have studied nerve conduction in rabbits with EAE. We report here that most of the large diameter afferent fibres are blocked in the region of the dorsal root ganglion and at the dorsal root entry zone, thus accounting for the loss of tendon jerks and also, through the severe loss of proprioceptive information, the ataxia of these animals. We conclude that whenever clinical comparisons are made between EAE and multiple sclerosis, the pathophysiology associated with the histological damage of the peripheral nervous system must be taken into account.

  2. Associations between abnormal ultrasound color Doppler measures and tendon pain symptoms in badminton players during a season: a prospective cohort study.

    PubMed

    Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren; Christensen, Robin; Boesen, Lars; Hölmich, Per; Nielsen, Michael Bachmann; Koenig, Merete Juhl; Hartkopp, Andreas; Ellegaard, Karen; Bliddal, Henning; Langberg, Henning

    2012-03-01

    Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear. Intratendinous flow is present and associated with pain in badminton players, and intratendinous flow and pain increase during a badminton season. Cohort study (prognosis); Level of evidence, 2. Ninety-five semiprofessional badminton players were included in the study at a tournament at the start of the badminton season. All players were interviewed regarding pain. The anterior knee tendons and Achilles tendons were studied. Each tendon was scored using a quantitative grading system (grades 0-5) and a qualitative scoring system (color fraction) using color Doppler ultrasound. Eight months later, 86 of the players (91%) were retested by the same investigators during an equivalent badminton tournament (including 1032 tendon regions; 86 players with 4 tendons each with 3 regions), thus forming the study group. At the start of the season, 24 players (28%) experienced pain in 37 tendons (11%), and at the end of the season, 31 players (36%) experienced pain in 51 tendons (15%), which was a statistically significant increase (P = .0002). Abnormal flow was found in 230 tendon regions in 71 players (83%) at the start of the season compared with 78 tendon regions in 41 players (48%) at the follow-up. The decrease in abnormal flow was statistically significant (P < .0001). Of the 37 painful tendons at the start of the season, 25 had abnormal flow (68%). In contrast, 131 tendons (85%) with abnormal flow at the start of the season were pain free. At the end of the season, 18 of the 51 painful tendons (35%) had abnormal flow. Ninety-six of the 131 pain-free tendons (73%) with abnormal flow at the start of the season were normalized (no pain and normal flow) at the end of the season. It was not possible to verify any association between intratendinous flow and pain at the start of the season or at the follow-up (end of the season). Intratendinous flow at the start of the season could not predict symptomatic outcome at the end of the season. The decrease in Doppler flow during the season might suggest that intratendinous flow could be part of a physiological adaptive response to loading and that intratendinous flow as previously believed is not always a sign of pathological changes.

  3. From mini-invasive to non-invasive treatment using monopolar radiofrequency: the next orthopaedic frontier.

    PubMed

    Whipple, Terry L

    2009-10-01

    Tendinopathy arises from a failed tendon healing process. Current non-invasive therapeutic alternatives are anti-inflammatory in nature, and outcomes are unpredictable. The benefit of invasive alternatives resides in the induction of the healing response. A new technology that uses non-invasive monopolar capacitive coupled radiofrequency has demonstrated the ability to raise temperatures in tendons and ligaments above 50 degrees C, the threshold for collagen modulation, tissue shrinkage and recruitment of macrophages, fibroblasts, and heat shock protein factors, without damaging the overlying structures, resulting in activation of the wound healing response. Monopolar capacitive-coupled radiofrequency offers a new non-invasive choice for tendinopathies and sprained ligaments. It does not interfere with subsequent surgical procedures should they become necessary.

  4. Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.

    PubMed

    Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher

    2016-03-01

    To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Marked innervation but also signs of nerve degeneration in between the Achilles and plantaris tendons and presence of innervation within the plantaris tendon in midportion Achilles tendinopathy

    PubMed Central

    Spang, C.; Harandi, V.M.; Alfredson, H.; Forsgren, S.

    2015-01-01

    Objectives: The plantaris tendon is increasingly recognised as an important factor in midportion Achilles tendinopathy. Its innervation pattern is completely unknown. Methods: Plantaris tendons (n=56) and associated peritendinous tissue from 46 patients with midportion Achilles tendinopathy and where the plantaris tendon was closely related to the Achilles tendon were evaluated. Morphological evaluations and stainings for nerve markers [general (PGP9.5), sensory (CGRP), sympathetic (TH)], glutamate NMDA receptor and Schwann cells (S-100β) were made. Results: A marked innervation, as evidenced by evaluation for PGP9.5 reactions, occurred in the peritendinous tissue located between the plantaris and Achilles tendons. It contained sensory and to some extent sympathetic and NMDAR1-positive axons. There was also an innervation in the zones of connective tissue within the plantaris tendons. Interestingly, some of the nerve fascicles showed a partial lack of axonal reactions. Conclusion: New information on the innervation patterns for the plantaris tendon in situations with midportion Achilles tendinopathy has here been obtained. The peritendinous tissue was found to be markedly innervated and there was also innervation within the plantaris tendon. Furthermore, axonal degeneration is likely to occur. Both features should be further taken into account when considering the relationship between the nervous system and tendinopathy. PMID:26032213

  6. Predictors and effects of patellofemoral pain following hamstring-tendon ACL reconstruction.

    PubMed

    Culvenor, Adam G; Collins, Natalie J; Vicenzino, Bill; Cook, Jill L; Whitehead, Timothy S; Morris, Hayden G; Crossley, Kay M

    2016-07-01

    Patellofemoral pain is a frequent and troublesome complication following anterior cruciate ligament reconstruction (ACLR), irrespective of graft source. Yet, little is known about the factors associated with patellofemoral pain following hamstring-tendon ACLR. Retrospective analysis of potential patellofemoral pain predictors, and cross-sectional analysis of possible patellofemoral pain consequences. Potential predictors (pre-injury patellofemoral pain and activity level, concomitant patellofemoral cartilage damage and meniscectomy, age, sex, and surgical delay) and consequences (hopping performance, quality of life, kinesiophobia, and return to sport rates and attitudes) of patellofemoral pain 12 months following hamstring-tendon ACLR were assessed in 110 participants using univariate and multivariate analyses. Thirty-three participants (30%) had patellofemoral pain at 12 months post-ACLR. Older age at the time of ACLR was the only predictor of post-operative patellofemoral pain. Following ACLR, those with patellofemoral pain had a higher body mass index, and worse physical performance, quality of life, kinesiophobia and return to sport attitudes. Patellofemoral pain has a significant burden on individuals 12 months following hamstring-tendon ACLR. Clinicians need to be cognisant of patellofemoral pain, particularly in older individuals and those with a higher body mass index. The importance of considering psychological factors that are not typically addressed during ACLR rehabilitation, such as kinesiophobia, quality of life and return to sport attitudes is emphasised. Copyright © 2016. Published by Elsevier Ltd.

  7. Effects of isotretinoin treatment on cartilage and tendon thicknesses: an ultrasonographic study.

    PubMed

    Yıldızgören, Mustafa Turgut; Karataş Toğral, Arzu; Baki, Ali Erdem; Ekiz, Timur

    2015-07-01

    Effects of retinoic acid on collagen synthesis and cartilage have previously been shown. However, its effects on cartilage and tendons in humans have not been studied yet. Therefore, in order to provide a morphologic insight, the aim of this study was to measure femoral cartilage, Achilles and supraspinatus tendon thicknesses in patients under systemic isotretinoin treatment by using ultrasound. Fifteen patients (nine F, six M) who used isotretinoin for their acnes were included. All patients were treated with isotretinoin 0.5 mg/kg/day for the first month, and the dosage was escalated up to 1 mg/kg/day thereafter. Distal femoral cartilage, supraspinatus, and Achilles tendons thicknesses have been evaluated both before the treatment and at the end of the third month. Femoral cartilage thicknesses were assessed from three midpoints bilaterally; medial condyle, lateral condyle, and intercondylar area. Short/long-axis diameters and cross-sectional area of the Achilles tendons and axial tendon thicknesses of supraspinatus tendon were evaluated from the nondominant side. The mean age of the patients was 20.1 ± 4.9 years, and body mass index was 21.7 ± 2.5 kg/m(2). Although posttreatment cartilage measurements of 30 knees were lower for the three midpoints, it reached significance only for lateral condyle (p = 0.05). In addition, posttreatment tendon measurements were not statistically significant compared with pretreatment values (all p > 0.05). Systemic isotretinoin treatment seems to make cartilage thinner. Further studies considering histological and molecular evaluations with more sample sizes are awaited.

  8. Tendon transfer to reconstruct wrist extension in children with obstetric brachial plexus palsy.

    PubMed

    Al-Qattan, M M

    2003-04-01

    This study reports on 20 children with obstetric brachial plexus palsy who underwent a tendon transfer to reconstruct wrist extension. The mean age at the time of tendon transfer was 8 years. There were seven patients with Erb's palsy and the remaining 13 had total palsy. The flexor carpi ulnaris was utilized 15 times and the flexor carpi radialis five times. The transferred tendon was sutured to the tendon of the extensor carpi radialis brevis. The result of the transfer was assessed according to a modified Medical Research Council (MRC) muscle grading system. A good result was obtained in 18 patients (modified MRC grade of 4) and a fair result (modified MRC grade of 3) in two. The choice of tendon transfer to reconstruct the wrist drop deformity in various conditions including adult traumatic brachial plexus injuries is discussed.

  9. Regular physical activity reduces the effects of Achilles tendon vibration on postural control for older women.

    PubMed

    Maitre, J; Serres, I; Lhuisset, L; Bois, J; Gasnier, Y; Paillard, T

    2015-02-01

    The aim was to determine in what extent physical activity influences postural control when visual, vestibular, and/or proprioceptive systems are disrupted. Two groups of healthy older women: an active group (74.0 ± 3.8 years) who practiced physical activities and a sedentary group (74.7 ± 6.3 years) who did not, underwent 12 postural conditions consisted in altering information emanating from sensory systems by means of sensory manipulations (i.e., eyes closed, cervical collar, tendon vibration, electromyostimulation, galvanic vestibular stimulation, foam surface). The center of foot pressure velocity was recorded on a force platform. Results indicate that the sensory manipulations altered postural control. The sedentary group was more disturbed than the active group by the use of tendon vibration. There was no clear difference between the two groups in the other conditions. This study suggests that the practice of physical activities is beneficial as a means of limiting the effects of tendon vibration on postural control through a better use of the not manipulated sensory systems and/or a more efficient reweighting to proprioceptive information from regions unaffected by the tendon vibration. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Glucocorticoids induce specific ion-channel-mediated toxicity in human rotator cuff tendon: a mechanism underpinning the ultimately deleterious effect of steroid injection in tendinopathy?

    PubMed

    Dean, Benjamin John Floyd; Franklin, Sarah Louise; Murphy, Richard J; Javaid, Muhammad K; Carr, Andrew Jonathan

    2014-12-01

    Glucocorticoid injection (GCI) and surgical rotator cuff repair are two widely used treatments for rotator cuff tendinopathy. Little is known about the way in which medical and surgical treatments affect the human rotator cuff tendon in vivo. We assessed the histological and immunohistochemical effects of these common treatments on the rotator cuff tendon. Controlled laboratory study. Supraspinatus tendon biopsies were taken before and after treatment from 12 patients undergoing GCI and 8 patients undergoing surgical rotator cuff repair. All patients were symptomatic and none of the patients undergoing local GCI had full thickness tears of the rotator cuff. The tendon tissue was then analysed using histological techniques and immunohistochemistry. There was a significant increase in nuclei count and vascularity after rotator cuff repair and not after GCI (both p=0.008). Hypoxia inducible factor 1α (HIF-1α) and cell proliferation were only increased after rotator cuff repair (both p=0.03) and not GCI. The ionotropic N-methyl-d-aspartate receptor 1 (NMDAR1) glutamate receptor was only increased after GCI and not rotator cuff repair (p=0.016). An increase in glutamate was seen in both groups following treatment (both p=0.04), while an increase in the receptor metabotropic glutamate receptor 7 (mGluR7) was only seen after rotator cuff repair (p=0.016). The increases in cell proliferation, vascularity and HIF-1α after surgical rotator cuff repair appear consistent with a proliferative healing response, and these features are not seen after GCI. The increase in the glutamate receptor NMDAR1 after GCI raises concerns about the potential excitotoxic tendon damage that may result from this common treatment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. The influence of exercise during growth on ultrasonographic parameters of the superficial digital flexor tendon of young Thoroughbred horses.

    PubMed

    Moffat, P A; Firth, E C; Rogers, C W; Smith, R K W; Barneveld, A; Goodship, A E; Kawcak, C E; McIlwraith, C W; van Weeren, P R

    2008-03-01

    Conditioning by early training may influence the composition of certain musculoskeletal tissues, but very few data exist on its effect during growth on tendon structure and function. To investigate whether conditioning exercise in young foals would lead to any ultrasonographically detectable damage to the superficial digital flexor tendon or an increase in cross-sectional area (CSA). Thirty-three Thoroughbred foals reared at pasture were allocated to 2 groups: control (PASTEX) allowed exercise freely at pasture; and CONDEX, also at pasture, began conditioning exercise from mean age 21 days over 1030 m on a purpose-built oval grass track, for 5 days/week until mean age 18 months. Foals were observed daily, and underwent orthopaedic examination monthly. Ultrasonographic images of the superficial digital flexor tendon (SDFT) at the mid-metacarpal level of both forelimbs were obtained in all foals at ages 5, 8, 12, 15 and 18 months. CSA was validated (r(2) = 0.89) by determining CSA from digital photographs of the transected SDFT surface from 12 of the horses necropsied at age 17.1 months. here was no clinical or ultrasonographic evidence of tendonopathy in either group and the greatest increase in mean CSA in both groups occurred between age 5 and 8 months. Across all age categories, there was no significant difference in mean CSA between the left and right limbs, or colts and fillies; there was a trend towards a larger CSA in the CONDEX group (P = 0.058). There was no conclusive evidence for a structural adaptive hypertrophy of the SDFT, probably because the regimen was insufficiently rigorous or because spontaneous pasture exercise may induce maximal development of energy storing tendons. A moderate amount of early conditioning exercise against a background of constant exercise at pasture is not harmful to the development of the flexor tendons.

  12. Beta-tricalcium phosphate plugs for press-fit fixation in ACL reconstruction--a mechanical analysis in bovine bone.

    PubMed

    Mayr, Hermann O; Hube, Robert; Bernstein, Anke; Seibt, Alexander B; Hein, Werner; von Eisenhart-Rothe, Ruediger

    2007-06-01

    The goal of this study was to test fixation properties of microporous pure beta-tricalcium phosphate (TCP) plugs (porosity 40%) for press-fit fixation of the ACL graft using patellar tendons with and without bone blocks. We set out to establish whether it is possible, in this way, to obtain results comparable with those of interference screw fixation of bone-tendon-bone (BTB) grafts in terms of cyclic loading and load-to-failure. In a bovine model 30 ACL grafts were fixed in tibial drill holes, divided into three groups: 10 BTB grafts fixed with TCP press-fit plugs (7x25 mm), 10 pure patellar tendon grafts with TCP press-fit plugs (7x25 mm), and 10 BTB grafts with metal interference screws (7x25 mm). All grafts were tested by cyclic loading (50-200 N) and loaded until failure in a tensiometer. Under cyclic loading one interference screw fixation failed. None of the TCP plug fixations failed. After 1500 cycles the displacement of the graft in the drill hole for BTB fixed with screws was 3.6+/-7.8 mm, for BTB/TCP plugs 1.6+/-3.4 mm, and for the pure tendon/TCP grafts 1.4+/-0.4 mm. Regarding cyclic loading the pure tendon/TCP system was significantly superior to BTB (p=0.007). The load-to-failure for the BTB/interference screw group was 908+/-539 N with a stiffness of 94+/-36 N/mm, 936+/-245 N for the BTB/TCP cylinder group with a stiffness of 98+/-12 N/mm, and 673+/-159 N for the pure tendon/TCP group with a stiffness of 117+/-9 N/mm. In terms of pull-out load the BTB/TCP system was significantly better than the pure tendon/TCP group (p=0.011). However, pure tendon/TCP grafts achieved significantly greater stiffness (p=0.002) than the BTB system. Press-fit fixation with microporous pure beta-TCP plugs of BTB grafts or patellar tendon grafts without bone blocks for ACL reconstruction leads to primary stability comparable with that achieved by fixation with metal interference screws in case of BTB grafts.

  13. Aspartic Acid Racemization and Collagen Degradation Markers Reveal an Accumulation of Damage in Tendon Collagen That Is Enhanced with Aging*

    PubMed Central

    Thorpe, Chavaunne T.; Streeter, Ian; Pinchbeck, Gina L.; Goodship, Allen E.; Clegg, Peter D.; Birch, Helen L.

    2010-01-01

    Little is known about the rate at which protein turnover occurs in living tendon and whether the rate differs between tendons with different physiological roles. In this study, we have quantified the racemization of aspartic acid to calculate the age of the collagenous and non-collagenous components of the high strain injury-prone superficial digital flexor tendon (SDFT) and low strain rarely injured common digital extensor tendon (CDET) in a group of horses with a wide age range. In addition, the turnover of collagen was assessed indirectly by measuring the levels of collagen degradation markers (collagenase-generated neoepitope and cross-linked telopeptide of type I collagen). The fractional increase in d-Asp was similar (p = 0.7) in the SDFT (5.87 × 10−4/year) and CDET (5.82 × 10−4/year) tissue, and d/l-Asp ratios showed a good correlation with pentosidine levels. We calculated a mean (±S.E.) collagen half-life of 197.53 (±18.23) years for the SDFT, which increased significantly with horse age (p = 0.03) and was significantly (p < 0.001) higher than that for the CDET (34.03 (±3.39) years). Using similar calculations, the half-life of non-collagenous protein was 2.18 (±0.41) years in the SDFT and was significantly (p = 0.04) lower than the value of 3.51 (±0.51) years for the CDET. Collagen degradation markers were higher in the CDET and suggested an accumulation of partially degraded collagen within the matrix with aging in the SDFT. We propose that increased susceptibility to injury in older individuals results from an inability to remove partially degraded collagen from the matrix leading to reduced mechanical competence. PMID:20308077

  14. Altered Achilles tendon function during walking in people with diabetic neuropathy: implications for metabolic energy saving.

    PubMed

    Petrovic, M; Maganaris, C N; Deschamps, K; Verschueren, S M; Bowling, F L; Boulton, A J M; Reeves, N D

    2018-05-01

    The Achilles tendon (AT) has the capacity to store and release elastic energy during walking, contributing to metabolic energy savings. In diabetes patients, it is hypothesized that a stiffer Achilles tendon may reduce the capacity for energy saving through this mechanism, thereby contributing to an increased metabolic cost of walking (CoW). The aim of this study was to investigate the effects of diabetes and diabetic peripheral neuropathy (DPN) on the Achilles tendon and plantarflexor muscle-tendon unit behavior during walking. Twenty-three nondiabetic controls (Ctrl); 20 diabetic patients without peripheral neuropathy (DM), and 13 patients with moderate/severe DPN underwent gait analysis using a motion analysis system, force plates, and ultrasound measurements of the gastrocnemius muscle, using a muscle model to determine Achilles tendon and muscle-tendon length changes. During walking, the DM and particularly the DPN group displayed significantly less Achilles tendon elongation (Ctrl: 1.81; DM: 1.66; and DPN: 1.54 cm), higher tendon stiffness (Ctrl: 210; DM: 231; and DPN: 240 N/mm), and higher tendon hysteresis (Ctrl: 18; DM: 21; and DPN: 24%) compared with controls. The muscle fascicles of the gastrocnemius underwent very small length changes in all groups during walking (~0.43 cm), with the smallest length changes in the DPN group. Achilles tendon forces were significantly lower in the diabetes groups compared with controls (Ctrl: 2666; DM: 2609; and DPN: 2150 N). The results strongly point toward the reduced energy saving capacity of the Achilles tendon during walking in diabetes patients as an important factor contributing to the increased metabolic CoW in these patients. NEW & NOTEWORTHY From measurements taken during walking we observed that the Achilles tendon in people with diabetes and particularly people with diabetic peripheral neuropathy was stiffer, was less elongated, and was subject to lower forces compared with controls without diabetes. These altered properties of the Achilles tendon in people with diabetes reduce the tendon's energy saving capacity and contribute toward the higher metabolic energy cost of walking in these patients.

  15. Power amplification in an isolated muscle–tendon unit is load dependent

    PubMed Central

    Sawicki, Gregory S.; Sheppard, Peter; Roberts, Thomas J.

    2015-01-01

    ABSTRACT During rapid movements, tendons can act like springs, temporarily storing work done by muscles and then releasing it to power body movements. For some activities, such as frog jumping, energy is released from tendon much more rapidly than it is stored, thus amplifying muscle power output. The period during which energy is loaded into a tendon by muscle work may be aided by a catch mechanism that restricts motion, but theoretical studies indicate that power can be amplified in a muscle–tendon load system even in the absence of a catch. To explore the limits of power amplification with and without a catch, we studied the bullfrog plantaris muscle–tendon during in vitro contractions. A novel servomotor controller allowed us to measure muscle–tendon unit (MTU) mechanical behavior during contractions against a variety of simulated inertial-gravitational loads, ranging from zero to 1× the peak isometric force of the muscle. Power output of the MTU system was load dependent and power amplification occurred only at intermediate loads, reaching ∼1.3× the peak isotonic power output of the muscle. With a simulated anatomical catch mechanism in place, the highest power amplification occurred at the lowest loads, with a maximum amplification of more than 4× peak isotonic muscle power. At higher loads, the benefits of a catch for MTU performance diminished sharply, suggesting that power amplification >2.5× may come at the expense of net mechanical work delivered to the load. PMID:26449973

  16. Unifying principles in terrestrial locomotion: do hopping Australian marsupials fit in?

    PubMed

    Bennett, M B

    2000-01-01

    Mammalian terrestrial locomotion has many unifying principles. However, the Macropodoidea are a particularly interesting group that exhibit a number of significant deviations from the principles that seem to apply to other mammals. While the properties of materials that comprise the musculoskeletal system of mammals are similar, evidence suggests that tendon properties in macropodoid marsupials may be size or function dependent, in contrast to the situation in placental mammals. Postural differences related to hopping versus running have a dramatic effect on the scaling of the pelvic limb musculoskeletal system. Ratios of muscle fibre to tendon cross-sectional areas for ankle extensors and digital flexors scale with positive allometry in all mammals, but exponents are significantly higher in macropods. Tendon safety factors decline with increasing body mass in mammals, with eutherians at risk of ankle extensor tendon rupture at a body mass of about 150 kg, whereas kangaroos encounter similar problems at a body mass of approximately 35 kg. Tendon strength appears to limit locomotor performance in these animals. Elastic strain energy storage in tendons is mass dependent in all mammals, but exponents are significantly larger in macropodid. Tibial stresses may scale with positive allometry in kangaroos, which result in lower bone safety factors in macropods compared to eutherian mammals.

  17. Position Control of Tendon-Driven Fingers

    NASA Technical Reports Server (NTRS)

    Abdallah, Muhammad E.; Platt, Robert, Jr.; Hargrave, B.; Pementer, Frank

    2011-01-01

    Conventionally, tendon-driven manipulators implement some force control scheme based on tension feedback. This feedback allows the system to ensure that the tendons are maintained taut with proper levels of tensioning at all times. Occasionally, whether it is due to the lack of tension feedback or the inability to implement sufficiently high stiffnesses, a position control scheme is needed. This work compares three position controllers for tendon-driven manipulators. A new controller is introduced that achieves the best overall performance with regards to speed, accuracy, and transient behavior. To compensate for the lack of tension feedback, the controller nominally maintains the internal tension on the tendons by implementing a two-tier architecture with a range-space constraint. These control laws are validated experimentally on the Robonaut-2 humanoid hand. I

  18. Transcription factor scleraxis vitally contributes to progenitor lineage direction in wound healing of adult tendon in mice.

    PubMed

    Sakabe, Tomoya; Sakai, Keiko; Maeda, Toru; Sunaga, Ataru; Furuta, Nao; Schweitzer, Ronen; Sasaki, Takako; Sakai, Takao

    2018-04-20

    Tendon is a dense connective tissue that transmits high mechanical forces from skeletal muscle to bone. The transcription factor scleraxis (Scx) is a highly specific marker of both precursor and mature tendon cells (tenocytes). Mice lacking scx exhibit a specific and virtually complete loss of tendons during development. However, the functional contribution of Scx to wound healing in adult tendon has not yet been fully characterized. Here, using ScxGFP -tracking and loss-of-function systems, we show in an adult mouse model of Achilles tendon injury that paratenon cells, representing a stem cell antigen-1 (Sca-1)-positive and Scx-negative progenitor subpopulation, display Scx induction, migrate to the wound site, and produce extracellular matrix (ECM) to bridge the defect, whereas resident tenocytes exhibit a delayed response. Scx induction in the progenitors is initiated by transforming growth factor β (TGF-β) signaling. scx -deficient mice had migration of Sca-1-positive progenitor cell to the lesion site but impaired ECM assembly to bridge the defect. Mechanistically, scx -null progenitors displayed higher chondrogenic potential with up-regulation of SRY-box 9 (Sox9) coactivator PPAR-γ coactivator-1α (PGC-1α) in vitro , and knock-in analysis revealed that forced expression of full-length scx significantly inhibited Sox9 expression. Accordingly, scx -null wounds formed cartilage-like tissues that developed ectopic ossification. Our findings indicate a critical role of Scx in a progenitor-cell lineage in wound healing of adult mouse tendon. These progenitor cells could represent targets in strategies to facilitate tendon repair. We propose that this lineage-regulatory mechanism in tissue progenitors could apply to a broader set of tissues or biological systems in the body. © 2018 Sakabe et al.

  19. [Complex trauma of the hand].

    PubMed

    Pechlaner, S; Hussl, H

    1998-01-01

    The hand is very exposed to injuries in the daily man's work. The multiple functions of the hand are based on vitality, sensibility, motor function and stability. In severe hand injuries the functional results of the repair are often very poor. In a complex injury of the hand we are faced with the damage of the soft tissue and bone and the loss of vitality and function of the hand. The cause of hand injuries are mainly a crush trauma or the rotating saw. Basically, we recommend an extended primary repair. After the radical debridement we have to reconstruct the damaged structures. We start doing the osteosynthesis and stabilization of the joints. Thereafter, suturing of extensor and flexor tendons. Then, we do the microsurgical reconstructions of vessels and nerves. In case tendons and bones are exposed we have to cover the defect with a pedicled or a free flap. In a long ischemic time we have to change our concept and do the reconstruction of the vessels first. Our results in vitality and sensibility are listed. In the result of a complex hand injury each single functional restoration is very important. Therefore, it is necessary that severe hand injuries are treated at well established centres for hand surgery.

  20. Foot segmental motion and coupling in stage II and III tibialis posterior tendon dysfunction.

    PubMed

    Van de Velde, Maarten; Matricali, Giovanni Arnoldo; Wuite, Sander; Roels, Charlotte; Staes, Filip; Deschamps, Kevin

    2017-06-01

    Classification systems developed in the field of posterior tibialis tendon dysfunction omit to include dynamic measurements. Since this may negatively affect the selection of the most appropriate treatment modality, studies on foot kinematics are highly recommended. Previous research characterised the foot kinematics in patients with posterior tibialis tendon dysfunction. However, none of the studies analysed foot segmental motion synchrony during stance phase, nor compared the kinematic behaviour of the foot in presence of different posterior tibialis tendon dysfunction stages. Therefore, we aimed at comparing foot segmental motion and coupling in patients with posterior tibialis tendon dysfunction grade 2 and 3 to those of asymptomatic subjects. Foot segmental motion of 11 patients suffering from posterior tibialis tendon dysfunction stage 2, 4 patients with posterior tibialis tendon dysfunction stage 3 and 15 asymptomatic subjects was objectively quantified with the Rizzoli foot model using an instrumented walkway and a 3D passive motion capture system. Dependent variables were the range of motion occurring at the different inter-segment angles during subphases of stance and swing phase as well as the cross-correlation coefficient between a number of segments. Significant differences in range of motion were predominantly found during the forefoot push off phase and swing phase. In general, both patient cohorts demonstrated a reduced range of motion compared to the control group. This hypomobility occurred predominantly in the rearfoot and midfoot (p<0.01). Significant differences between both posterior tibialis tendon dysfunction patient cohorts were not revealed. Cross-correlation coefficients highlighted a loss of joint coupling between rearfoot and tibia as well as between rearfoot and forefoot in both posterior tibialis tendon dysfunction groups. The current evidence reveals considerable mechanical alterations in the foot which should be considered in the decision making process since it may help explaining the success and failure of certain conservative and surgical interventions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Tendon neuroplastic training: changing the way we think about tendon rehabilitation: a narrative review

    PubMed Central

    Rio, Ebonie; Kidgell, Dawson; Moseley, G Lorimer; Docking, Sean; Purdam, Craig; Cook, Jill

    2016-01-01

    Tendinopathy can be resistant to treatment and often recurs, implying that current treatment approaches are suboptimal. Rehabilitation programmes that have been successful in terms of pain reduction and return to sport outcomes usually include strength training. Muscle activation can induce analgesia, improving self-efficacy associated with reducing one's own pain. Furthermore, strength training is beneficial for tendon matrix structure, muscle properties and limb biomechanics. However, current tendon rehabilitation may not adequately address the corticospinal control of the muscle, which may result in altered control of muscle recruitment and the consequent tendon load, and this may contribute to recalcitrance or symptom recurrence. Outcomes of interest include the effect of strength training on tendon pain, corticospinal excitability and short interval cortical inhibition. The aims of this concept paper are to: (1) review what is known about changes to the primary motor cortex and motor control in tendinopathy, (2) identify the parameters shown to induce neuroplasticity in strength training and (3) align these principles with tendon rehabilitation loading protocols to introduce a combination approach termed as tendon neuroplastic training. Strength training is a powerful modulator of the central nervous system. In particular, corticospinal inputs are essential for motor unit recruitment and activation; however, specific strength training parameters are important for neuroplasticity. Strength training that is externally paced and akin to a skilled movement task has been shown to not only reduce tendon pain, but modulate excitatory and inhibitory control of the muscle and therefore, potentially tendon load. An improved understanding of the methods that maximise the opportunity for neuroplasticity may be an important progression in how we prescribe exercise-based rehabilitation in tendinopathy for pain modulation and potentially restoration of the corticospinal control of the muscle-tendon complex. PMID:26407586

  2. Three dimensional microstructural network of elastin, collagen, and cells in Achilles tendons.

    PubMed

    Pang, Xin; Wu, Jian-Ping; Allison, Garry T; Xu, Jiake; Rubenson, Jonas; Zheng, Ming-Hao; Lloyd, David G; Gardiner, Bruce; Wang, Allan; Kirk, Thomas Brett

    2017-06-01

    Similar to most biological tissues, the biomechanical, and functional characteristics of the Achilles tendon are closely related to its composition and microstructure. It is commonly reported that type I collagen is the predominant component of tendons and is mainly responsible for the tissue's function. Although elastin has been found in varying proportions in other connective tissues, previous studies report that tendons contain very small quantities of elastin. However, the morphology and the microstructural relationship among the elastic fibres, collagen, and cells in tendon tissue have not been well examined. We hypothesize the elastic fibres, as another fibrillar component in the extracellular matrix, have a unique role in mechanical function and microstructural arrangement in Achilles tendons. It has been shown that elastic fibres present a close connection with the tenocytes. The close relationship of the three components has been revealed as a distinct, integrated and complex microstructural network. Notably, a "spiral" structure within fibril bundles in Achilles tendons was observed in some samples in specialized regions. This study substantiates the hierarchical system of the spatial microstructure of tendon, including the mapping of collagen, elastin and tenocytes, with 3-dimensional confocal images. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1203-1214, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. Asynchronous Alterations of Muscle Force and Tendon Stiffness Following 8 Weeks of Resistance Exercise with Whole-Body Vibration in Older Women.

    PubMed

    Han, Seong-Won; Lee, Dae-Yeon; Choi, Dong-Sung; Han, Boram; Kim, Jin-Sun; Lee, Hae-Dong

    2017-04-01

    This study aimed to examine whether muscle force and tendon stiffness in a muscle-tendon complex alter synchronously following 8-week whole-body vibration (WBV) training in older people. Forty older women aged 65 years and older were randomly assigned into control (CON, n = 15) and whole-body vibration (WBV) training groups (exposure time, n = 13; vibration intensity, n = 12). For the training groups, a 4-week detraining period was completed following the training period. Throughout the training/detraining period, force of the medial gastrocnemius (MG) muscle and stiffness of the Achilles tendon were assessed four times (0, 4, 8, and 12 weeks) using a combined system of dynamometer and ultrasonography. While muscle force gradually increased throughout the training period (p < .05), a significant increase in tendon stiffness was observed after 8 weeks (p < .05). These findings indicated that, during the early phase of WBV training, muscle force and tendon stiffness changed asynchronously, which might be a factor in possible musculotendinous injuries.

  4. Quantification of temperature effect on impedance monitoring via PZT interface for prestressed tendon anchorage

    NASA Astrophysics Data System (ADS)

    Huynh, Thanh-Canh; Kim, Jeong-Tae

    2017-12-01

    In this study, the quantification of temperature effect on impedance monitoring via a PZT interface for prestressed tendon-anchorage is presented. Firstly, a PZT interface-based impedance monitoring technique is selected to monitor impedance signatures by predetermining sensitive frequency bands. An analytical model is designed to represent coupled dynamic responses of the PZT interface-tendon anchorage system. Secondly, experiments on a lab-scaled tendon anchorage are described. Impedance signatures are measured via the PZT interface for a series of temperature and prestress-force changes. Thirdly, temperature effects on measured impedance responses of the tendon anchorage are estimated by quantifying relative changes in impedance features (such as RMSD and CCD indices) induced by temperature variation and prestress-force change. Finally, finite element analyses are conducted to investigate the mechanism of temperature variation and prestress-loss effects on the impedance responses of prestressed tendon anchorage. Temperature effects on impedance monitoring are filtered by effective frequency shift-based algorithm for distinguishing prestress-loss effects on impedance signatures.

  5. Human grasp assist device and method of use

    NASA Technical Reports Server (NTRS)

    Linn, Douglas Martin (Inventor); Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor)

    2012-01-01

    A grasp assist device includes a glove portion having phalange rings, contact sensors for measuring a grasping force applied by an operator wearing the glove portion, and a tendon drive system (TDS). The device has flexible tendons connected to the phalange rings for moving the rings in response to feedback signals from the sensors. The TDS is connected to each of the tendons, and applies an augmenting tensile force thereto via a microcontroller adapted for determining the augmenting tensile force as a function of the grasping force. A method of augmenting a grasping force of an operator includes measuring the grasping force using the sensors, encoding the grasping force as the feedback signals, and calculating the augmenting tensile force as a function of the feedback signals using the microcontroller. The method includes energizing at least one actuator of a tendon drive system (TDS) to thereby apply the augmenting tensile force.

  6. Examination of toxicity and collagen linearity after the administration of the protein cross-linker genipin in equine tendon and dermis: a pilot study.

    PubMed

    Bellefeuille, M; Peters, D F; Nolin, M; Slusarewicz, P; Telgenhoff, D

    2017-05-01

    Collagen cross-linking is an attractive therapeutic route aimed at supplementing natural collagen stabilisation. In this study the toxicity of the cross-linker genipin (GP) was examined in avascular (tendon) and vascular (dermis) tissue. High doses of GP were injected intratendinously into three yearling horses and evaluated at various time points up to 30 days. A second group of three yearlings were injected into the dermis and evaluated at various time points up to 1 year. Metrics used included lameness, circumferential swelling, ultrasound evaluation, microscopic morphology, collagen production and systemic effect on blood parameters. The tendon injection sites exhibited mild lameness and swelling with no apparent systemic toxicity or stabilisation defects. Treated tendons exhibited increased linear collagen microscopically. Dermal injections showed similar results, with mild swelling at the injection site. Microscopic morphology resulted in a decrease in dermal collagen at 30 days post-injection. Dermis injected at the high dose of 355 mmol/L examined 1 year post-treatment appeared similar to the untreated biopsies; however, there was an increase in mature collagen. GP injection appeared to be well tolerated, with transient lameness and mild circumferential swelling when injected into the tendon and local tissue swelling when injected into the dermis. No systemic hypersensitivities or toxicities were observed. Microscopically, GP resulted in increased linear collagen in tendons at 30 days post-injection and overall increased collagen in dermal tissue when evaluated 1 year post-injection. © 2017 Australian Veterinary Association.

  7. [Reconstruction of big rotator cuff ruptures. A new technique of tendon refixation with the corkscrew suture anchor system].

    PubMed

    Kessler, M A; Lichtenberg, S; Habermeyer, P

    2003-10-01

    Tendon retraction and fatty degeneration is a major problem in repair of massive rotator cuff tears. Especially in the transosseous refixation technique, a tension-free refixation cannot be obtained in all cases. The purpose of this prospective study was to evaluate the postoperative results using a new tension-free reinsertion technique with a Corkscrew suture anchor system. Thirty patients (25 males, 5 females) with complete one and two tendon tears underwent open rotator cuff repair (rupture of one tendon: n=14, 47%). The torn tendons were mobilized and reinserted medially to reduce tension. Medialization was achieved by inserting tendon near the osteochondral border in a bony trough. The number of implanted suture anchors ranged from 2 to 6 (mean: 3.56). The mean age was 56 years (39-68 years) with a follow-up of 24 months (17-33 months). In one patient physical and sonographic examination showed a complete and in two patients a partial rerupture. A temporarily frozen shoulder occurred in two cases. No infection or rejection response was seen. In no case was revision surgery necessary. No displacement or loosening of the Corkscrew anchors was noticed. The constant score improved from 45 points preoperatively to 85 points at the time of follow-up (mean). The Corkscrew suture anchor system in combination with the new suture technique offers the possibility of a stable reinsertion even in reduced calcified bone structure. This facilitates good conditions for stable fibroblastic healing. Our midterm results show good osseous union combined with a low rerupture rate.

  8. Repair of insertional achilles tendinosis with a bone-quadriceps tendon graft.

    PubMed

    Philippot, Rémi; Wegrzyn, Julien; Grosclaude, Sophie; Besse, Jean Luc

    2010-09-01

    While conservative treatment may be successful in most cases, partial rupture at the calcaneal insertion point is a significant concern with insertional Achilles tendinopathy. We report on the outcomes of a surgical technique for Achilles tendon augmentation using a bone-tendon graft harvested from the knee extensor system. Our retrospective case series includes 25 surgical procedures performed in 24 patients, 19 males and five females, with a mean age of 47 (range, 30 to 59) years, 18 of whom were athletes. The mean followup period was 52 (range, 12 to 156) months. All patients underwent MRI examination prior to surgery which showed partial Achilles tendon rupture. The Achilles tendon was debrided through a posterolateral approach. The bone-quadriceps tendon graft was harvested, then the bone plug of the graft was inserted into a blind tunnel drilled into the calcaneus and fixed with an interference screw. The fibers of the quadriceps tendon were sutured to the residual part of the Achilles tendon with the foot at an angle of 90 degrees. Patients were able to resume their sporting activity after an average of 6.7 months. At last followup examination, physical activity was scored 5.2 on the 10-point Tegner Scale; the mean AOFAS score was 98.4. MRI examination showed good graft integration 1 year postoperatively. The bone-quadriceps tendon grafting technique was a good alternative for the insertional Achilles lesions with partial detachment which we felt required augmentation.

  9. A novel approach using tendon vibration of the human flexor carpi radialis muscle to study spinal reflexes.

    PubMed

    Tsang, Kenneth; de Bruin, Hubert; Archambeault, Mark

    2008-01-01

    Although most muscle spindle investigations have used the cat model and invasive measurement techniques, several investigators have used microneurography to record from the Ia and II fibres in humans during tendon vibration. In these studies the muscle spindle primary endings are stimulated using transverse vibration of the tendon at reflex sub-threshold amplitudes. Others have used low amplitude vibration and the stretch evoked M-wave response to determine reflex properties during both agonist and antagonist voluntary contractions. In the past we have developed a PC based instrument that uses Labview and a linear servomotor to study tendon reflex properties by recording stretch evoked M-wave responses from single tendon taps or electrical stimuli to the afferent nerve. In this paper we describe a further development of this system to provide precise vibrations of the tendon up to 65 Hz with amplitudes up to 4 mm. The resultant M-wave train is extracted from background noise via phase coherent subtractive filtering. Test results from vibrating the human distal flexor carpi radialis tendon at 10 and 30 Hz, for relaxed, slight flexion and slight extension, are also presented.

  10. Long-term post-tensioned beam exposure test specimens : final evaluation.

    DOT National Transportation Integrated Search

    2003-08-01

    In the last few years, the effectiveness of cement grout in galvanized or polyethylene ducts, the most widely used corrosion protection system for : multistrand bonded post-tensioned concrete tendons, has been under debate, due to significant tendon ...

  11. Maturational alterations in gap junction expression and associated collagen synthesis in response to tendon function.

    PubMed

    Young, N J; Becker, D L; Fleck, R A; Goodship, A E; Patterson-Kane, J C

    2009-07-01

    Energy-storing tendons including the equine superficial digital flexor tendon (SDFT) contribute to energetic efficiency of locomotion at high-speed gaits, but consequently operate close to their physiological strain limits. Significant evidence of exercise-induced microdamage has been found in the SDFT which appears not to exhibit functional adaptation; the degenerative changes have not been repaired by the tendon fibroblasts (tenocytes), and are proposed to accumulate and predispose the tendon to rupture during normal athletic activity. The anatomically opposing common digital extensor tendon (CDET) functions only to position the digit, experiencing significantly lower levels of strain and is rarely damaged by exercise. A number of studies have indicated that tenocytes in the adult SDFT are less active in collagen synthesis and turnover than those in the immature SDFT or the CDET. Gap junction intercellular communication (GJIC) is known to be necessary for strain-induced collagen synthesis by tenocytes. We postulate therefore that expression of GJ proteins connexin 43 and 32 (Cx43; Cx32), GJIC and associated collagen expression levels are high in the SDFT and CDET of immature horses, when the SDFT in particular grows significantly in cross-sectional area, but reduce significantly during maturation in the energy-storing tendon only. The hypothesis was tested using tissue from the SDFT and CDET of foetuses, foals, and young adult Thoroughbred horses. Cellularity and the total area of both Cx43 and Cx32 plaques/mm(2) of tissue reduced significantly with maturation in each tendon. However, the total Cx43 plaque area per tenocyte significantly increased in the adult CDET. Evidence of recent collagen synthesis in the form of levels of neutral salt-soluble collagen, and collagen type I mRNA was significantly less in the adult compared with the immature SDFT; procollagen type I amino-propeptide (PINP) and procollagen type III amino-propeptide (PIIINP) levels per mm(2) of tissue and PINP expression per tenocyte also decreased with maturation in the SDFT. In the CDET PINP and PIIINP expression per tenocyte increased in the adult, and exceeded those in the adult SDFT. The level of PINP per mm(2) was greater in the adult CDET than in the SDFT despite the higher cellularity of the latter tendon. In the adult SDFT, levels of PIIINP were greater than those of PINP, suggesting relatively greater synthesis of a weaker form of collagen previously associated with microdamage. Tenocytes in monolayers showed differences in Cx43 and Cx32 expression compared with those in tissue, however there were age- and tendon-specific phenotypic differences, with a longer time for 50% recovery of fluorescence after photobleaching in adult SDFT cells compared with those from the CDET and immature SDFT. As cellularity reduces following growth in the SDFT, a failure of the remaining tenocytes to show a compensatory increase in GJ expression and collagen synthesis may explain why cell populations are not able to respond to exercise and to repair microdamage in some adult athletes. Enhancing GJIC in mature energy-storing tendons could provide a strategy to increase the cellular synthetic and reparative capacity.

  12. Cutaneous manifestations of phosphate solution extravasation.

    PubMed

    Verykiou, S; Aljefri, K; Gopee, H; Taheri, L; Charlton, F; Langtry, J A; Blasdale, C

    2018-01-01

    Extravasation injuries are common in patients receiving multiple intravenous infusions. Although such injuries are closely associated with the infusion of cytotoxic chemotherapy, they have also been been associated with extravasation of noncytotoxic drugs. Extravasation injuries can lead to skin ulceration and nerve and tendon damage, and therefore to permanent disability. We report three cases of phosphate solution extravasation leading to unusual cutaneous manifestations. © 2017 British Association of Dermatologists.

  13. The Effects of Mechanical Loading on Tendons - An In Vivo and In Vitro Model Study

    PubMed Central

    Zhang, Jianying; Wang, James H-C.

    2013-01-01

    Mechanical loading constantly acts on tendons, and a better understanding of its effects on the tendons is essential to gain more insights into tendon patho-physiology. This study aims to investigate tendon mechanobiological responses through the use of mouse treadmill running as an in vivo model and mechanical stretching of tendon cells as an in vitro model. In the in vivo study, mice underwent moderate treadmill running (MTR) and intensive treadmill running (ITR) regimens. Treadmill running elevated the expression of mechanical growth factors (MGF) and enhanced the proliferative potential of tendon stem cells (TSCs) in both patellar and Achilles tendons. In both tendons, MTR upregulated tenocyte-related genes: collagen type I (Coll. I ∼10 fold) and tenomodulin (∼3–4 fold), but did not affect non-tenocyte-related genes: LPL (adipocyte), Sox9 (chondrocyte), Runx2 and Osterix (both osteocyte). However, ITR upregulated both tenocyte (Coll. I ∼7–11 fold; tenomodulin ∼4–5 fold) and non-tenocyte-related genes (∼3–8 fold). In the in vitro study, TSCs and tenocytes were stretched to 4% and 8% using a custom made mechanical loading system. Low mechanical stretching (4%) of TSCs from both patellar and Achilles tendons increased the expression of only the tenocyte-related genes (Coll. I ∼5–6 fold; tenomodulin ∼6–13 fold), but high mechanical stretching (8%) increased the expression of both tenocyte (Coll. I ∼28–50 fold; tenomodulin ∼14–48 fold) and non-tenocyte-related genes (2–5-fold). However, in tenocytes, non-tenocyte related gene expression was not altered by the application of either low or high mechanical stretching. These findings indicate that appropriate mechanical loading could be beneficial to tendons because of their potential to induce anabolic changes in tendon cells. However, while excessive mechanical loading caused anabolic changes in tendons, it also induced differentiation of TSCs into non-tenocytes, which may lead to the development of degenerative tendinopathy frequently seen in clinical settings. PMID:23977130

  14. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    PubMed

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a desirable outcome in operative recovery, tendon fixation, and complications.

  15. Influence of Muscle-Tendon Wrapping on Calculations of Joint Reaction Forces in the Equine Distal Forelimb

    PubMed Central

    Merritt, Jonathan S.; Davies, Helen M. S.; Burvill, Colin; Pandy, Marcus G.

    2008-01-01

    The equine distal forelimb is a common location of injuries related to mechanical overload. In this study, a two-dimensional model of the musculoskeletal system of the region was developed and applied to kinematic and kinetic data from walking and trotting horses. The forces in major tendons and joint reaction forces were calculated. The components of the joint reaction forces caused by wrapping of tendons around sesamoid bones were found to be of similar magnitude to the reaction forces between the long bones at each joint. This finding highlighted the importance of taking into account muscle-tendon wrapping when evaluating joint loading in the equine distal forelimb. PMID:18509485

  16. Viscoelastic properties of healthy achilles tendon are independent of isometric plantar flexion strength and cross-sectional area.

    PubMed

    Suydam, Stephen M; Soulas, Elizabeth M; Elliott, Dawn M; Silbernagel, Karin Gravare; Buchanan, Thomas S; Cortes, Daniel H

    2015-06-01

    Changes in tendon viscoelastic properties are observed after injuries and during healing as a product of altered composition and structure. Continuous Shear Wave Elastography is a new technique measuring viscoelastic properties of soft tissues using external shear waves. Tendon has not been studied with this technique, therefore, the aims of this study were to establish the range of shear and viscosity moduli in healthy Achilles tendons, determine bilateral differences of these parameters and explore correlations of viscoelasticity to plantar flexion strength and tendon area. Continuous Shear Wave Elastography was performed over the free portion of both Achilles tendons from 29 subjects. Isometric plantar flexion strength and cross sectional area were measured. The average shear and viscous moduli was 83.2 kPa and 141.0 Pa-s, respectively. No correlations existed between the shear or viscous modulus and area or strength. This indicates that viscoelastic properties can be considered novel, independent biomarkers. The shear and viscosity moduli were bilaterally equivalent (p = 0.013, 0.017) which allows determining pathologies through side-to-side deviations. The average bilateral coefficient of variation was 7.2% and 9.4% for shear and viscosity modulus, respectively. The viscoelastic properties of the Achilles tendon may provide an unbiased, non-subjective rating system of tendon recovery and optimizing treatment strategies. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Viscoelastic Properties of Healthy Achilles Tendon are Independent of Isometric Plantar Flexion Strength and Cross-Sectional Area

    PubMed Central

    Suydam, Stephen M.; Soulas, Elizabeth M.; Elliott, Dawn M.; Silbernagel, Karin Gravare; Buchanan, Thomas S.; Cortes, Daniel H.

    2015-01-01

    Changes in tendon viscoelastic properties are observed after injuries and during healing as a product of altered composition and structure. Continuous Shear Wave Elastography is a new technique measuring viscoelastic properties of soft tissues using external shear waves. Tendon has not been studied with this technique, therefore, the aims of this study were to establish the range of shear and viscosity moduli in healthy Achilles tendons, determine bilateral differences of these parameters and explore correlations of viscoelasticity to plantar flexion strength and tendon area. Continuous Shear Wave Elastography was performed over the free portion of both Achilles tendons from 29 subjects. Isometric plantar flexion strength and cross sectional area were measured. The average shear and viscous moduli was 83.2kPa and 141.0Pa-s, respectively. No correlations existed between the shear or viscous modulus and area or strength. This indicates that viscoelastic properties can be considered novel, independent biomarkers. The shear and viscosity moduli were bilaterally equivalent (p=0.013,0.017) which allows determining pathologies through side-to-side deviations. The average bilateral coefficient of variation was 7.2% and 9.4% for shear and viscosity modulus, respectively. The viscoelastic properties of the Achilles tendon may provide an unbiased, non-subjective rating system of tendon recovery and optimizing treatment strategies. PMID:25882209

  18. Surgical repair of chronic patellar tendon rupture in total knee replacement with ipsilateral hamstring tendons.

    PubMed

    Spoliti, Marco; Giai Via, Alessio; Padulo, Johnny; Oliva, Francesco; Del Buono, Angelo; Maffulli, Nicola

    2016-10-01

    Patellar tendon rupture is a serious complication of total knee arthroplasty (TKA). Its reconstruction in patients with chronic ruptures is technically demanding. This article reports the results of surgical reconstruction of neglected patellar tendon rupture in TKA using autologous hamstring tendons. Nine TKA patients (six women and three men) (mean age at index surgery 68 years) with chronic patellar tendon tears underwent reconstruction with ipsilateral hamstrings tendon, leaving the distal insertion in situ. The clinical diagnosis was supported by imaging (anterior-posterior and 30° flexion lateral radiographs). Insall-Salvati index, range of motion, and leg extension test were recorded preoperatively and at last follow-up. The modified Cincinnati rating system and the Kujala score were administered. The patients sustained the patellar tendon tear an average of 8 weeks before the procedure. At final follow-up of 4 years (range 2-8 years), the median of extension lag was 5° (range 0°-15°; DS = 5). The median of post-operative Insall-Salvati index was 1.4 (range 1.3-1.8; SD = 0.15; p = 0.002) compared to the preoperative index of 1.7 (range 1.5-2.2; SD = 0.23). The mean modified Cincinnati and Kujala scores significantly increased compared with the preoperative ones (p < 0.01). At final follow-up, all patients were able to walk without brace or aids, and they were satisfied with the procedure. Based on our retrospective study of nine patients, reconstruction of neglected patellar tendon rupture in TKA with autologous hamstring tendons is feasible and safe, and provides good functional recovery. Case series, Level IV.

  19. Do athletes alter their running mechanics after an Achilles tendon rupture?

    PubMed

    Jandacka, Daniel; Silvernail, Julia Freedman; Uchytil, Jaroslav; Zahradnik, David; Farana, Roman; Hamill, Joseph

    2017-01-01

    Over the past thirty years, there has been dramatic increase in incidence of Achilles tendon rupture in the athletic population. The purpose of this study was to compare the lower extremity mechanics of Achilles tendon ruptured runners with healthy controls. The participants with a past history of an Achilles tendon repair ( n  = 11) and healthy control ( n  = 11) subgroups were matched on sex, age, type of regular physical activity, mass, height, footfall pattern and lateral dominancy. Running kinetics and kinematics of the ankle, knee and hip were recorded using a high-speed motion capture system interfaced with a force platform. Achilles tendon length was measured using ultrasonography. Main outcome measures were lower extremity joint angles and moments during stance phase of running and Achilles tendon lengths. Athletes from Achilles tendon group had an affected gastro-soleus complex. Athletes with history of Achilles tendon rupture had reduced ankle range of motion during second half of the stance phase of running (Δ7.6°), an overextended knee during initial contact (Δ5.2°) and increased affected knee range of motion (Δ4.4°) during the first half of stance phase on their affected limb compared to the healthy control group. There was a 22% increase in the maximal hip joint moment on contralateral side of the Achilles tendon group compared to the healthy controls. These results suggest a compensation mechanism, relatively extended knee at initial ground contact against the deficit in the muscle-tendon complex of the triceps surae. Overextension during sporting activities may place the knee at risk for further injury. Avoidance of AT lengthening and plantarflexion strength deficit after surgery and during rehabilitation might help to manage AT rupture since these factors may be responsible for altered running kinematics.

  20. Modified Kidner procedure utilizing a Mitek bone anchor.

    PubMed

    Dawson, D M; Julsrud, M E; Erdmann, B B; Jacobs, P M; Ringstrom, J B

    1998-01-01

    The recent development of small bone suture anchors has created several potential applications in reconstructive surgery of the foot. Mitek bone anchors are simple to insert, require less aggressive dissection and surgical time than reefing of the redundant posterior tibial tendon, and are a reliable method of tendon-to-bone fixation. Mitek bone anchors are an excellent technique for the treatment of redundant tibialis posterior tendon following a modified Kidner procedure. In modified Kidner procedures involving an excessively large os tibiale externum, Mitek anchoring of the redundant tibialis posterior tendon to the navicular bone is an excellent means for secure plication of the posterior tibial tendon in cases involving intraoperative tendon laxity. A description of the Mitek Anchor System and technique of application in a modified Kinder procedure is presented. The purpose of this study was to describe patient satisfaction and long-term clinical outcomes of the modified Kinder procedure with and without the Mitek bone anchoring system. A retrospective study of the modified Kinder procedure was performed with 13 patients being evaluated, seven with Mitek anchoring and six without. The University of Maryland 100-point Painful Foot Center Scoring System was modified to be more specific to the modified Kinder procedure for assessment of subjective long-term results. Patient overall satisfaction was rated good to excellent by 85.6% of patients in the Mitek group and by 100% of patients in the non-Mitek group. Use of the Mitek anchor allowed for quicker postoperative recovery to resumption of ambulation without assistive devices (average of 3 weeks vs. 4.42 weeks) and a quicker return to pain-free ambulation in normal shoegear (average of 4 weeks vs. 6 weeks). Mitek anchoring of the tibialis posterior tendon, theoretically, increases medial arch support as evidenced by 14% of the Mitek group and 67% of the non-Mitek group requiring postoperative orthotics.

  1. Cellular response of healing tissue to DegraPol tube implantation in rabbit Achilles tendon rupture repair: an in vivo histomorphometric study.

    PubMed

    Buschmann, Johanna; Meier-Bürgisser, Gabriella; Bonavoglia, Eliana; Neuenschwander, Peter; Milleret, Vincent; Giovanoli, Pietro; Calcagni, Maurizio

    2013-05-01

    In tendon rupture repair, improvements such as higher primary repair strength, anti-adhesion and accelerated healing are needed. We developed a potential carrier system of an electrospun DegraPol tube, which was tightly implanted around a transected and conventionally sutured rabbit Achilles tendon. Histomorphometric analysis of the tendon tissue 12 weeks postoperation showed that the tenocyte density, tenocyte morphology and number of inflammation zones were statistically equivalent, whether or not DegraPol tube was implanted; only the collagen fibres were slightly less parallelly orientated in the tube-treated case. Comparison of rabbits that were operated on both hind legs with ones that were operated on only one hind leg showed that there were significantly more inflammation zones in the two-leg cases compared to the one-leg cases, while the implantation of a DegraPol tube had no such adverse effects. These findings are a prerequisite for using DegraPol tube as a carrier system for growth factors, cytokines or stem cells in order to accelerate the healing process of tendon tissue. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Effect of Age and Exercise on the Viscoelastic Properties of Rat Tail Tendon

    PubMed Central

    LaCroix, Andrew S.; Duenwald-Kuehl, Sarah E.; Brickson, Stacey; Akins, Tiffany L.; Diffee, Gary; Aiken, Judd; Vanderby, Ray; Lakes, Roderic S.

    2013-01-01

    Tendon mechanical properties are thought to degrade during aging but improve with exercise. A remaining question is whether exercise in aged animals provides sufficient regenerative, systemic stimulus to restore younger mechanical behaviors. Herein we address that question with tail tendons from aged and exercised rats, which would be subject to systemic effects but not direct loading from the exercise regimen. Twenty-four month old rats underwent one of three treadmill exercise training protocols for 12 months: sedentary (walking at 0° incline for 5 min/day), moderate (running at 0° incline for 30 min/day), or high (running at 4° incline for 30 min/day). A group of 9 month old rats were used to provide an adult control, while a group of 3 month old rats provided a young control. Tendons were harvested at sacrifice and mechanically tested. Results show significant age-dependent differences in modulus, ultimate stress, relaxation rate, and percent relaxation. Relaxation rate was strain-dependent, consistent with nonlinear superposition or Schapery models but not with quasilinear viscoelasticity (QLV). Trends in exercise data suggest that with exercise, tendons assume the elastic character of younger rats (lower elastic modulus and ultimate stress). PMID:23549897

  3. A bFGF-releasing silk/PLGA-based biohybrid scaffold for ligament/tendon tissue engineering using mesenchymal progenitor cells.

    PubMed

    Sahoo, Sambit; Toh, Siew Lok; Goh, James C H

    2010-04-01

    An ideal scaffold that provides a combination of suitable mechanical properties along with biological signals is required for successful ligament/tendon regeneration in mesenchymal stem cell-based tissue engineering strategies. Among the various fibre-based scaffolds that have been used, hybrid fibrous scaffolds comprising both microfibres and nanofibres have been recently shown to be particularly promising. This study developed a biohybrid fibrous scaffold system by coating bioactive bFGF-releasing ultrafine PLGA fibres over mechanically robust slowly-degrading degummed knitted microfibrous silk scaffolds. On the ECM-like biomimetic architecture of ultrafine fibres, sustained release of bFGF mimicked the ECM in function, initially stimulating mesenchymal progenitor cell (MPC) proliferation, and subsequently, their tenogeneic differentiation. The biohybrid scaffold system not only facilitated MPC attachment and promoted cell proliferation, with cells growing both on ultrafine PLGA fibres and silk microfibres, but also stimulated tenogeneic differentiation of seeded MPCs. Upregulated gene expression of ligament/tendon-specific ECM proteins and increased collagen production likely contributed to enhancing mechanical properties of the constructs, generating a ligament/tendon analogue that has the potential to be used to repair injured ligaments/tendons. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. [Use of tissue engineering in the reconstruction of flexor tendon injuries of the hand].

    PubMed

    Bíró, Vilmos

    2015-02-08

    In his literary analysis, the author describes a novel method applied in the reconstruction of flexor tendon injuries of the hand. This procedure is named tissue engineering, and it is examined mainly under experimental circumstances. After definition of the method and descriptions of literary preliminaries the author discusses the healing process of the normal tendon tissue, then development of the scaffold, an important step of tissue engineering is described. After these topics the introduction of the pluripotent mesenchymal stem cells into the scaffold, and proliferation of these cells and development of the sliding systems are presented. The mechanical resisting ability of the formed tendon tissue is also discussed. Finally, the author concludes that as long as results of experimental research cannot be successfully applied into clinical practice, well-tried tendon reconstruction operations and high quality postoperative rehabilitation are needed.

  5. Melt electrowriting below the critical translation speed to fabricate crimped elastomer scaffolds with non-linear extension behaviour mimicking that of ligaments and tendons.

    PubMed

    Hochleitner, Gernot; Chen, Fei; Blum, Carina; Dalton, Paul D; Amsden, Brian; Groll, Jürgen

    2018-05-01

    Ligaments and tendons are comprised of aligned, crimped collagen fibrils that provide tissue-specific mechanical properties with non-linear extension behaviour, exhibiting low stress at initial strain (toe region behaviour). To approximate this behaviour, we report fibrous scaffolds with sinusoidal patterns by melt electrowriting (MEW) below the critical translation speed (CTS) by exploitation of the natural flow behaviour of the polymer melt. More specifically, we synthesised photopolymerizable poly(L-lactide-co-ε-caprolactone-co-acryloyl carbonate) (p(LLA-co-ε-CL-co-AC)) and poly(ε-caprolactone-co-acryloyl carbonate) (p(ε-CL-co-AC)) by ring-opening polymerization (ROP). Single fibre (fØ = 26.8 ± 1.9 µm) tensile testing revealed a customisable toe region with Young's Moduli ranging from E = 29 ± 17 MPa for the most crimped structures to E = 314 ± 157 MPa for straight fibres. This toe region extended to scaffolds containing multiple fibres, while the sinusoidal pattern could be influenced by printing speed. The synthesized polymers were cytocompatible and exhibited a tensile strength of σ = 26 ± 7 MPa after 10 4 cycles of preloading at 10% strain while retaining the distinct toe region commonly observed in native ligaments and tendon tissue. Damaged tendons and ligaments are serious and frequently occurring injuries worldwide. Recent therapies, including autologous grafts, still have severe disadvantages leading to a demand for synthetic alternatives. Materials envisioned to induce tendon and ligament regeneration should be degradable, cytocompatible and mimic the ultrastructural and mechanical properties of the native tissue. Specifically, we utilised photo-cross-linkable polymers for additive manufacturing (AM) with MEW. In this way, we were able to direct-write cytocompatible fibres of a few micrometres thickness into crimp-structured elastomer scaffolds that mimic the non-linear biomechanical behaviour of tendon and ligament tissue. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. Tendon Reconstruction with Tissue Engineering Approach--A Review.

    PubMed

    Verdiyeva, Gunay; Koshy, Kiron; Glibbery, Natalia; Mann, Haroon; Seifalian, Alexander M

    2015-09-01

    Tendon injuries are a common and rising occurrence, associated with significant impairment to quality of life and financial burden to the healthcare system. Clinically, they represent an unresolved problem, due to poor natural tendon healing and the inability of current treatment strategies to restore the tendon to its native state. Tissue engineering offers a promising alternative, with the incorporation of scaffolds, cells and growth factors to support the complete regeneration of the tendon. The materials used in tendon engineering to date have provided significant advances in structural integrity and biological compatibility and in many cases the results obtained are superior to those observed in natural healing. However, grafts fail to reproduce the qualities of the pre-injured tendon and each has weaknesses subject to its constituent parts. Furthermore, many materials and cell types are being investigated concurrently, with seemingly little association or comparison between research results. In this review the properties of the most-investigated and effective components have been appraised in light of the surrounding literature, with research from early in-vitro experiments to clinical trials being discussed. Extensive comparisons have been made between scaffolds, cell types and growth factors used, listing strengths and weaknesses to provide a stable platform for future research. Promising future endeavours are also described in the field of nanocomposite material science, stem cell sources and growth factors, which may bypass weaknesses found in individual elements. The future of tendon engineering looks bright, with growing understanding in material technology, cell and growth factor application and encouraging recent advances bringing us ever closer to regenerating the native tendon.

  7. Intermittent KoldBlue cryotherapy of 3x10 min changes mid-portion Achilles tendon microcirculation.

    PubMed

    Knobloch, Karsten; Grasemann, Ruth; Spies, Marcus; Vogt, Peter M

    2007-06-01

    Neovascularisation and microcirculatory changes have been reported in Achilles tendinopathy. Cryotherapy and compression, as part of a rest, ice, compression and elevation regimen, are shown to decrease pain and improve function. However, the microcirculatory changes following a given dosage of cryotherapy on mid-portion Achilles tendon remain unclear. Prospective clinical cohort study, level of evidence 2. 30 people (12 males, 33 (SD 12) years, body mass index 25.6 (5.3) kg/m2) were included in the cohort. 3x10 min KoldBlue ankle-cooling bandages were applied and microcirculation of Achilles tendon mid-portion was real-time and continuously assessed using a laser-Doppler-spectrophotometry system (O2C, Germany). Superficial capillary blood flow was reduced from 42 to 6, 5 and 3 relative units (rU) in the first, second and third cryotherapy periods, respectively (-65%, p = 0.001), with no significant capillary hyperaemia. Deep capillary tendon blood flow was reduced from 180 to 82, 53 and 52 rU (-71%, p = 0.001) within 6-9 min of application without hyperaemia. Superficial tendon oxygen saturation dropped significantly from 43% to 26%, 18% and 11% (p = 0.001) after repetitive cryotherapy, with persisting increase of tendon oxygenation during rewarming (51%, 49% and 54%, p = 0.077) up to 27% of the baseline level. At 8 mm tendon depth, cryotherapy preserved local oxygenation. Relative postcapillary venous tendon filling pressures were favourably reduced from 41 (11) to 31, 28 and 26 rU (-36%, p = 0.001) superficially and from 56 (11) to 45, 46 and 48 rU (-18%, p = 0.001) in deep capillary blood flow during cryotherapy, facilitating capillary venous clearance. Intermittent cryotherapy of 3x10 min significantly decreases local Achilles tendon mid-portion capillary blood flow by 71%. Within 2 min of rewarming, tendon oxygen saturation is re-established following cryotherapy. Postcapillary venous filling pressures are reduced during cryotherapy, favouring capillary venous outflow of the healthy Achilles tendon.

  8. Changes in Achilles tendon moment arm from rest to maximum isometric plantarflexion: in vivo observations in man

    PubMed Central

    Maganaris, Constantinos N; Baltzopoulos, Vasilios; Sargeant, Anthony J

    1998-01-01

    The purpose of the present study was to examine the effect of a plantarflexor maximum voluntary contraction (MVC) on Achilles tendon moment arm length. Sagittal magnetic resonance (MR) images of the right ankle were taken in six subjects both at rest and during a plantarflexor MVC in the supine position at a knee angle of 90 deg and at ankle angles of -30 deg (dorsiflexed direction), -15 deg, 0 deg (neutral ankle position), +15 deg (plantarflexed direction), +30 deg and +45 deg. A system of mechanical stops, support triangles and velcro straps was used to secure the subject in the above positions. Location of a moving centre of rotation was calculated for ankle rotations from -30 to 0 deg, -15 to +15 deg, 0 to +30 deg and +15 to +45 deg. All instant centres of rotation were calculated both at rest and during MVC. Achilles tendon moment arms were measured at ankle angles of -15, 0, +15 and +30 deg. At any given ankle angle, Achilles tendon moment arm length during MVC increased by 1-1.5 cm (22-27%, P < 0.01) compared with rest. This was attributed to a displacement of both Achilles tendon by 0.6-1.1 cm (P < 0.01) and all instant centres of rotation by about 0.3 cm (P < 0.05) away from their corresponding resting positions. The findings of this study have important implications for estimating loads in the musculoskeletal system. Substantially unrealistic Achilles tendon forces and moments generated around the ankle joint during a plantarflexor MVC would be calculated using resting Achilles tendon moment arm measurements. PMID:9660906

  9. Changes in Achilles tendon moment arm from rest to maximum isometric plantarflexion: in vivo observations in man.

    PubMed

    Maganaris, C N; Baltzopoulos, V; Sargeant, A J

    1998-08-01

    1. The purpose of the present study was to examine the effect of a plantarflexor maximum voluntary contraction (MVC) on Achilles tendon moment arm length. 2. Sagittal magnetic resonance (MR) images of the right ankle were taken in six subjects both at rest and during a plantarflexor MVC in the supine position at a knee angle of 90 deg and at ankle angles of -30 deg (dorsiflexed direction), -15 deg, 0 deg (neutral ankle position), +15 deg (plantarflexed direction), +30 deg and +45 deg. A system of mechanical stops, support triangles and velcro straps was used to secure the subject in the above positions. Location of a moving centre of rotation was calculated for ankle rotations from -30 to 0 deg, -15 to +15 deg, 0 to +30 deg and +15 to +45 deg. All instant centres of rotation were calculated both at rest and during MVC. Achilles tendon moment arms were measured at ankle angles of -15, 0, +15 and +30 deg. 3. At any given ankle angle, Achilles tendon moment arm length during MVC increased by 1-1.5 cm (22-27 %, P < 0.01) compared with rest. This was attributed to a displacement of both Achilles tendon by 0.6-1.1 cm (P < 0.01) and all instant centres of rotation by about 0.3 cm (P < 0.05) away from their corresponding resting positions. 4. The findings of this study have important implications for estimating loads in the musculoskeletal system. Substantially unrealistic Achilles tendon forces and moments generated around the ankle joint during a plantarflexor MVC would be calculated using resting Achilles tendon moment arm measurements.

  10. Eyelid reanimation with gold weight implant and tendon sling suspension: evaluation of excursion and velocity using the FACIAL CLIMA system.

    PubMed

    Hontanilla, Bernardo; Marre, Diego

    2013-04-01

    This study aims to analyse the efficacy of static techniques, namely gold weight implant and tendon sling, in the reanimation of the paralytic eyelid. Upper eyelid rehabilitation in terms of excursion and blinking velocity is performed using the automatic motion capture system, FACIAL CLIMA. Seventy-four patients underwent a total of 101 procedures including 58 upper eyelid gold weight implants and 43 lower eyelid tendon suspension with 27 patients undergoing both procedures. The presence of lagophtalmos, eye dryness, corneal ulcer, epiphora and lower lid ptosis/ectropion was assessed preoperatively. The Wilcoxon signed-rank test was used to compare preoperative versus postoperative measurements of upper eyelid excursion and blinking velocity determined with FACIAL CLIMA. Significance was set at p <0.05. FACIAL CLIMA revealed significant improvement of eyelid excursion and velocity of blinking (p < 0.001). Eye dryness improved in 49 patients (90.7%) and corneal ulcer resolved without any further treatment in 12 (85.7%) of those with a gold weight inserted. Implant extrusion was observed in 8.6% of the cases. Of the patients with lower lid tendon suspension, correction of ptosis/ectropion and epiphora was achieved in 93.9% and 91.9% of cases, respectively. In eight patients (18.6%), further surgery was needed to adjust tendon tension. The paralytic upper and lower eyelid can be successfully managed with gold weight implant and tendon suspension. The FACIAL CLIMA system is a reliable method to quantify upper eyelid excursion and blinking velocity and to detect the exact position of the lower eyelid. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Medial Patellofemoral Ligament Reconstruction Procedure Using a Suspensory Femoral Fixation System

    PubMed Central

    Nakagawa, Shuji; Arai, Yuji; Kan, Hiroyuki; Ueshima, Keiichiro; Ikoma, Kazuya; Terauchi, Ryu; Kubo, Toshikazu

    2013-01-01

    Recurrent patellar dislocation has recently been treated with anatomic medial patellofemoral ligament (MPFL) reconstruction using a semitendinosus muscle tendon. Although it is necessary to add tension to fix the tendon graft without loading excess stress on the patellofemoral joint, adjustment of the tension can be difficult. To resolve this problem, we developed an MPFL reconstruction procedure using the ToggleLoc Fixation Device (Biomet, Warsaw, IN), in which the semitendinosus muscle tendon is folded and used as a double-bundle tendon graft and 2 bone tunnels and 1 bone tunnel are made on the patellar and femoral sides, respectively. The patellar side of the tendon graft is fixed with an EndoButton (Smith & Nephew, London, England), and the femoral side is fixed with the ToggleLoc. Stepless adjustment of tension of the tendon graft is possible by reducing the size of the loop of the ToggleLoc hung onto the tendon graft. It may be useful to position the patella in the center of the femoral sulcus by confirming the patellofemoral joint fitting. Stability can be confirmed by loading lateral stress on the patella in the extended knee joint. This procedure is less invasive because opening of the lateral side of the femur is not necessary, and it may be useful for MPFL reconstruction. PMID:24892014

  12. Hand Surgery In World War II. Medical Department, United States Army,

    DTIC Science & Technology

    1955-09-01

    Few of these patients presented deep cicatrices , latent infection was minimal, and as a rule the position of function was maintained. DEBARKATION...HOSPITAL 217 Many patients were received with large dorsal cicatrices which, although healed, were unstable. Joints and tendons not directly injured by...burns were frequently damaged by constriction and immobility because of superimposed cicatrices . Joint stiffness was likely to be even more pronounced

  13. The safety profile of a retrospective Accessory Postero-Lateral hind foot portal: the risk of sural nerve damage during visualisation of the Achilles tendon insertion.

    PubMed

    Carmont, M R; Stroud, R; Bjorndalen, H; Crowther, J; Ribbans, W J; Griffin, D

    2012-06-01

    The Accessory Postero-Lateral (AccPL) portal has recently been described to improve the visualisation for the endoscopic debridement of Haglund's tubercle. The safety of using this portal has been considered previously for posterior ankle arthroscopy. We performed a study to determine the proximity of the AccPL portal to the sural nerve. We compared the distances between AccPL and PL portals to the sural nerve in 17 cadaveric specimens. The AccPL portal was significantly closer (mean 12.0mm, range 6-19 mm, SD=3.64) to the sural nerve than the PL portal (mean 14.1mm, range 11-18 mm, SD=2.34) (t(16)=-2.34, p=0.03). In two cases the sural nerve was in contact with the clip but on close inspection, the nerve had not been damaged in any of the specimens. We conclude that the AccPL portal is a safe method to allow visualisation during endoscopic debridement of the Achilles tendon insertion. We also recommend that the portal is used for visualisation rather than instrumentation. Copyright © 2011 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  14. Gluteal Tendinopathy: A Review of Mechanisms, Assessment and Management.

    PubMed

    Grimaldi, Alison; Mellor, Rebecca; Hodges, Paul; Bennell, Kim; Wajswelner, Henry; Vicenzino, Bill

    2015-08-01

    Tendinopathy of the gluteus medius and gluteus minimus tendons is now recognized as a primary local source of lateral hip pain. The condition mostly occurs in mid-life both in athletes and in subjects who do not regularly exercise. Females are afflicted more than males. This condition interferes with sleep (side lying) and common weight-bearing tasks, which makes it a debilitating musculoskeletal condition with a significant impact. Mechanical loading drives the biological processes within a tendon and determines its structural form and load-bearing capacity. The combination of excessive compression and high tensile loads within tendons are thought to be most damaging. The available evidence suggests that joint position (particularly excessive hip adduction), together with muscle and bone elements, are key factors in gluteal tendinopathy. These factors provide a basis for a clinical reasoning process in the assessment and management of a patient presenting with localized lateral hip pain from gluteal tendinopathy. Currently, there is a lack of consensus as to which clinical examination tests provide best diagnostic utility. On the basis of the few diagnostic utility studies and the current understanding of the pathomechanics of gluteal tendinopathy, we propose that a battery of clinical tests utilizing a combination of provocative compressive and tensile loads is currently best practice in its assessment. Management of this condition commonly involves corticosteroid injection, exercise or shock wave therapy, with surgery reserved for recalcitrant cases. There is a dearth of evidence for any treatments, so the approach we recommend involves managing the load on the tendons through exercise and education on the underlying pathomechanics.

  15. A systematic literature review of US definitions, scoring systems and validity according to the OMERACT filter for tendon lesion in RA and other inflammatory joint diseases.

    PubMed

    Alcalde, María; D'Agostino, Maria Antonietta; Bruyn, George A W; Möller, Ingrid; Iagnocco, Annamaria; Wakefield, Richard J; Naredo, Esperanza

    2012-07-01

    To present the published data concerning the US assessment of tendon lesions as well as the US metric properties investigated in inflammatory arthritis. A systematic literature search of PubMed, Embase and the Cochrane Library was performed. Selection criteria were original articles in the English language reporting US, Doppler, tenosynovitis and other tendon lesions in patients with RA and other inflammatory arthritis. Data extraction focused on the definition and quantification of US-detected tenosynovitis and other tendon abnormalities and the metric properties of US according to the OMERACT filter for evaluating the above tendon lesions. Thirty-three of 192 identified articles were included in the review. Most articles were case series (42%) or case-control (33%) studies describing hand and/or foot tenosynovitis in RA patients. The majority of older articles used only B-mode, whereas the most recent studies have incorporated Doppler mode. Definition of tenosynovitis or other tendon lesion was provided in 70% of the evaluated studies. Most of the studies (61%) used a binary score for evaluating tendon abnormalities. Concerning the OMERACT filter, 24 (73%) articles dealt with construct validity. The comparator most commonly used was clinical assessment and MRI. There were few studies assessing criterion validity. Some studies evaluated reliability (36%), responsiveness (21%) and feasibility (12%). US seems a promising tool for evaluating inflammatory tendon lesions. However, further validation is necessary for implementation in clinical practice and trials.

  16. A new non-metallic anchorage system for post-tensioning applications using CFRP tendons

    NASA Astrophysics Data System (ADS)

    Taha, Mahmoud Reda

    The objective of the work described in this thesis is to design, develop and test a new non-metallic anchorage system for post-tensioning applications using CFRP tendons. The use of a non-metallic anchorage system should eliminate corrosion and deterioration concerns in the anchorage zone. The development of a reliable non-metallic anchorage would provide an important contribution to this field of knowledge. The idea of the new anchorage is to hold the tendon through mechanical gripping. The anchorage consists of a barrel with a conical housing and four wedges. The anchorage components are made of ultra high performance concrete (UHPC) specially developed for the anchorage. Sixteen concrete mixtures with different casting and curing regimes were examined to develop four UHPC mixtures with compressive strengths in excess of 200 MPa. The UHPC mixtures showed very dense microstructures with some unique characteristics. To enhance the fracture toughness of the newly developed UHPC, analytical and experimental analyses were performed. Using 3 mm chopped carbon fibres, a significant increase in the fracture toughness of UHPC was achieved. The non-metallic anchorage was developed with the UHPC with enhanced fracture toughness. The barrel required careful wrapping with CFRP sheets to provide the confinement required to utilize the strength and toughness of the UHPC. Thirty-three anchorages were tested under both static and dynamic loading conditions. The non-metallic anchorage showed excellent mechanical performance and fulfilled the different requirements of a post-tensioning anchorage system. The development of the new non-metallic anchorage will widen the inclusion of CFRP tendons in post-tensioned concrete/masonry structures. The new system will offer the opportunity to exploit CFRP tendons effectively creating an innovative generation of corrosion-free, smart structures.

  17. Macroscopic Rotator Cuff Tendinopathy and Histopathology Do Not Predict Repair Outcomes of Rotator Cuff Tears.

    PubMed

    Sethi, Paul M; Sheth, Chirag D; Pauzenberger, Leo; McCarthy, Mary Beth R; Cote, Mark P; Soneson, Emma; Miller, Seth; Mazzocca, Augustus D

    2018-03-01

    Numerous studies have identified factors that may affect the chances of rotator cuff healing after surgery. Intraoperative tendon quality may be used to predict healing and to determine type of repair and/or consideration of augmentation. There are no data that correlate how gross tendon morphology and degree of tendinopathy affect patient outcome or postoperative tendon healing. Purpose/Hypothesis: The purposes of this study were to (1) compare the gross appearance of the tendon edge during arthroscopic rotator cuff repair with its histological degree of tendinopathy and (2) determine if gross appearance correlated with postoperative repair integrity. The hypothesis was that gross (macroscopic) tendon with normal thickness, no delamination, and elastic tissue before repair would have a correlation with low Bonar scores, higher postoperative American Shoulder and Elbow Surgeons (ASES) scores, and increased rates of postoperative tendon healing on ultrasound. Cross-sectional study; Level of evidence, 3. A total of 105 patients undergoing repair of medium-size (1-3 cm) full-thickness rotator cuff tears were enrolled in the study. Intraoperatively, the supraspinatus tendon was rated on thickness, fraying, and stiffness. Tendon tissue was recovered for histological analysis based on the Bonar scoring system. Postoperative ASES and ultrasound assessment of healing were obtained 1 year after repair. Correlation between gross appearance of the tendon and rotator cuff histology was determined. Of the 105 patients, 85 were followed the study to completion. The mean age of the patients was 61.6 years; Bonar score, 7.5; preoperative ASES score, 49; and postoperative ASES score, 86. Ninety-one percent of repairs were intact on ultrasound. Gross appearance of torn rotator cuff tendon tissue did not correlate with histological appearance. Neither histological (Bonar) score nor gross appearance correlated with multivariate analysis of ASES score, postoperative repair status, or demographic data. The degree of tendinopathy did not correlate with morphological appearance of the tendon. Neither of these parameters correlated with healing or patient outcome. This study suggests that the degree of tendinopathy, unlike muscle atrophy, may not be predictive of outcomes and that, on appearance, poor quality tendon has adequate healing capacity. Therefore, abnormal gross tendon appearance should not affect the repair effort or technique.

  18. The surgical anatomy of the infrapatellar branch of the saphenous nerve in relation to incisions for anteromedial knee surgery.

    PubMed

    Kerver, A L A; Leliveld, M S; den Hartog, D; Verhofstad, M H J; Kleinrensink, G J

    2013-12-04

    Iatrogenic injury to the infrapatellar branch of the saphenous nerve is a common complication of surgical approaches to the anteromedial side of the knee. A detailed description of the relative anatomic course of the nerve is important to define clinical guidelines and minimize iatrogenic damage during anterior knee surgery. In twenty embalmed knees, the infrapatellar branch of the saphenous nerve was dissected. With use of a computer-assisted surgical anatomy mapping tool, safe and risk zones, as well as the location-dependent direction of the nerve, were calculated. The location of the infrapatellar branch of the saphenous nerve is highly variable, and no definite safe zone could be identified. The infrapatellar branch runs in neither a purely horizontal nor a vertical course. The course of the branch is location-dependent. Medially, it runs a nearly vertical course; medial to the patellar tendon, it has a -45° distal-lateral course; and on the patella and patellar tendon, it runs a close to horizontal-lateral course. Three low risk zones for iatrogenic nerve injury were identified: one is on the medial side of the knee, at the level of the tibial tuberosity, where a -45° oblique incision is least prone to damage the nerves, and two zones are located medial to the patellar apex (cranial and caudal), where close to horizontal incisions are least prone to damage the nerves. The infrapatellar branch of the saphenous nerve is at risk for iatrogenic damage in anteromedial knee surgery, especially when longitudinal incisions are made. There are three low risk zones for a safer anterior approach to the knee. The direction of the infrapatellar branch of the saphenous nerve is location-dependent. To minimize iatrogenic damage to the nerve, the direction of incisions should be parallel to the direction of the nerve when technically possible. These findings suggest that iatrogenic damage of the infrapatellar branch of the saphenous nerve can be minimized in anteromedial knee surgery when both the location and the location-dependent direction of the nerve are considered when making the skin incision.

  19. Effect of tendon tensioning: an in vitro study in porcine extensor tendons.

    PubMed

    Figueroa, David; Calvo, Rafael; Vaisman, Alex; Meleán, Patricio; Figueroa, Francisco

    2010-06-01

    Graft tensioning is a controversial issue in anterior cruciate ligament reconstruction (ACLR) that has not achieved consensus between peers. The purpose of this study is to determine if after tensioning tendon length and resistance to maximal load changes. We performed an in vitro study with 50 porcine extensors tendons. The first group (P=25) was tensioned with 80 N (19.97 lb) for 10 min, using an ACL graft preparation board. The second group (C=25) was used as control and was not tensioned. The average initial (groups P and C) and post tensioning tendon length (group C) were measured; the average initial and post tensioning tendon diameter were measured as well. All samples were fixated in a tube-clamp system connected to a tension sensor. The samples were stressed with continuous and progressive tension until ultimate failure at maximum load (UFML) occurs. The initial mean length was: P before tensioning=13.4 mm+/-1.4 mm (range 10.5-16.5); P after tensioning=13.8 mm+/-1.4 mm (range 11.5-16.5); C=13 mm+/-1.35 mm (p=0.005). The mean diameter was: P=5.6 mm (4.5-6); C=5.5 mm (range 4.5-6) (p>0.05). The UFML was: P=189.7 N (114-336); C=229.9 N (143-365) (p=0.029). Tendon tensioning with 80 N for 10 min produced 3% average elongation. These could be beneficial in ACLR since tendon tensioning decreases elongation of the graft after fixation. Regardless, tendon tensioning is not innocuous since it diminishes their resistance when continuously stressed until complete failure occurs.

  20. Characterization via atomic force microscopy of discrete plasticity in collagen fibrils from mechanically overloaded tendons: Nano-scale structural changes mimic rope failure.

    PubMed

    Baldwin, Samuel J; Kreplak, Laurent; Lee, J Michael

    2016-07-01

    Tendons exposed to tensile overload show a structural alteration at the fibril scale termed discrete plasticity. Serial kinks appear along individual collagen fibrils that are susceptible to enzymatic digestion and are thermally unstable. Using atomic force microscopy we mapped the topography and mechanical properties in dehydrated and hydrated states of 25 control fibrils and 25 fibrils displaying periodic kinks, extracted from overloaded bovine tail tendons. Using the measured modulus of the hydrated fibrils as a probe of molecular density, we observed a non-linear negative correlation between molecular density and kink density of individual fibrils. This is accompanied by an increase in water uptake with kink density and a doubling of the coefficient of variation of the modulus between kinked, and control fibrils. The mechanical property maps of kinked collagen fibrils show radial heterogeneity that can be modeled as a high-density core surrounded by a low-density shell. The core of the fibril contains the kink structures characteristic of discrete plasticity; separated by inter-kink regions, which often retain the D-banding structure. We propose that the shell and kink structures mimic characteristic damage motifs observed in laid rope strands. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Neuromuscular and muscle-tendon system adaptations to isotonic and isokinetic eccentric exercise.

    PubMed

    Guilhem, G; Cornu, C; Guével, A

    2010-06-01

    To present the properties of an eccentric contraction and compare neuromuscular and muscle-tendon system adaptations induced by isotonic and isokinetic eccentric trainings. An eccentric muscle contraction is characterized by the production of muscle force associated to a lengthening of the muscle-tendon system. This muscle solicitation can cause micro lesions followed by a regeneration process of the muscle-tendon system. Eccentric exercise is commonly used in functional rehabilitation for its positive effect on collagen synthesis but also for resistance training to increase muscle strength and muscle mass in athletes. Indeed, eccentric training stimulates muscle hypertrophy, increases the fascicle pennation angle, fascicles length and neural activation, thus inducing greater strength gains than concentric or isometric training programs. Eccentric exercise is commonly performed either against a constant external load (isotonic) or at constant velocity (isokinetic), inducing different mechanical constraints. These different mechanical constraints could induce structural and neural adaptive strategies specific to each type of exercise. The literature tends to show that isotonic mode leads to a greater strength gain than isokinetic mode. This observation could be explained by a greater neuromuscular activation after IT training. However, the specific muscle adaptations induced by each mode remain difficult to determine due to the lack of standardized, comparative studies. 2010 Elsevier Masson SAS. All rights reserved.

  2. Effects of plasma rich in growth factors (PRGF) on biomechanical properties of Achilles tendon repair.

    PubMed

    López-Nájera, Diego; Rubio-Zaragoza, Mónica; Sopena-Juncosa, Joaquín J; Alentorn-Geli, Eduard; Cugat-Bertomeu, Ramón; Fernández-Sarmiento, J Andrés; Domínguez-Pérez, Juan M; García-Balletbó, Montserrat; Primo-Capella, Víctor J; Carrillo-Poveda, José M

    2016-12-01

    To assess the biomechanical effects of intra-tendinous injections of PRGF on the healing Achilles tendon after repair in a sheep model. Thirty sheep were randomly assigned into one of the six groups depending on the type of treatment received (PRGF or placebo) and survival time (2, 4 and 8 weeks). The Achilles tendon injury was repaired by suturing the tendinous edges employing a three-loop pulley pattern. A trans-articular external fixation system was then used for immobilization. The PRGF or placebo was administered on a weekly basis completing a maximum of three infiltrations. The force, section and tension values were compared between the operated and healthy Achilles tendons across all groups. The PRGF-treated tendons had higher force at 8 weeks compared with the placebo group (p = 0.007). Between 2 and 4 weeks, a significant increase in force in both the PRGF-treated tendon (p = 0.0027) and placebo group (p = 0.0095) occurred. No significant differences were found for section ratio between PRGF-treated tendons and the placebo group for any of the time periods evaluated. At 2 weeks, PRGF-treated tendons had higher tension ratio compared with placebo group tendons (p = 0.0143). Both PRGF and placebo treatments significantly improved the force (p < 0.001 and p = 0.0095, respectively) and tension (p = 0.009 and p = 0.0039, respectively) ratios at 8 weeks compared with 2 weeks. The application of PRGF increases Achilles tendon repair strength at 8 weeks compared with the use of placebo. The use of PRGF does not modify section and tension ratios compared with placebo at 8 weeks. The tension ratio progressively increases between 2 and 8 weeks compared with the placebo.

  3. Effects of wrist tendon vibration on arm tracking in people poststroke.

    PubMed

    Conrad, Megan O; Scheidt, Robert A; Schmit, Brian D

    2011-09-01

    The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity.

  4. Effects of wrist tendon vibration on arm tracking in people poststroke

    PubMed Central

    Conrad, Megan O.; Scheidt, Robert A.

    2011-01-01

    The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity. PMID:21697444

  5. Efficacy of Various Analgesics on Shoulder Function and Rotator Cuff Tendon-to-Bone Healing in a Rat (Rattus norvegicus) Model

    PubMed Central

    Caro, Adam C; Tucker, Jennica J; Yannascoli, Sarah M; Dunkman, Andrew A; Thomas, Stephen J; Soslowsky, Louis J

    2014-01-01

    Although relief of postoperative pain is an imperative aspect of animal welfare, analgesics that do not interfere with the scientific goals of the study must be used. Here we compared the efficacy of different analgesic agents by using an established rat model of supraspinatus tendon healing and a novel gait-analysis system. We hypothesized that different analgesic agents would all provide pain relief in this model but would cause differences in tendon-to-bone healing and gait parameters. Buprenorphine, ibuprofen, tramadol–gabapentin, and acetaminophen were compared with a no-analgesia control group. Gait measures (stride length and vertical force) on the operative forelimb differed between the control group and both the buprenorphine (2 and 4 d postsurgery) and ibuprofen (2 d postsurgery) groups. Step length was different in the control group as compared with the tramadol–gabapentin (2 d after surgery), buprenorphine (2 and 4 d after surgery), and ibuprofen (2 d after surgery) groups. Regarding tendon-to-bone healing, the ibuprofen group showed less stiffness at the insertion site; no other differences in tendon-to-bone healing were detected. In summary, the analgesics evaluated were associated with differences in both animal gait and tendon-to-bone healing. This information will be useful for improving the management of postsurgical pain without adversely affecting tissue healing. Given its ability to improve gait without impeding healing, we recommend use of buprenorphine for postsurgical pain management in rats. In addition, our gait-analysis system can be used to evaluate new analgesics. PMID:24602546

  6. Intermittent KoldBlue cryotherapy of 3×10 min changes mid‐portion Achilles tendon microcirculation

    PubMed Central

    Knobloch, Karsten; Grasemann, Ruth; Spies, Marcus; Vogt, Peter M

    2007-01-01

    Background Neovascularisation and microcirculatory changes have been reported in Achilles tendinopathy. Cryotherapy and compression, as part of a rest, ice, compression and elevation regimen, are shown to decrease pain and improve function. However, the microcirculatory changes following a given dosage of cryotherapy on mid‐portion Achilles tendon remain unclear. Study design Prospective clinical cohort study, level of evidence 2. Methods 30 people (12 males, 33 (SD 12) years, body mass index 25.6 (5.3) kg/m2) were included in the cohort. 3×10 min KoldBlue ankle‐cooling bandages were applied and microcirculation of Achilles tendon mid‐portion was real‐time and continuously assessed using a laser‐Doppler‐spectrophotometry system (O2C, Germany). Results Superficial capillary blood flow was reduced from 42 to 6, 5 and 3 relative units (rU) in the first, second and third cryotherapy periods, respectively (−65%, p = 0.001), with no significant capillary hyperaemia. Deep capillary tendon blood flow was reduced from 180 to 82, 53 and 52 rU (−71%, p = 0.001) within 6–9 min of application without hyperaemia. Superficial tendon oxygen saturation dropped significantly from 43% to 26%, 18% and 11% (p = 0.001) after repetitive cryotherapy, with persisting increase of tendon oxygenation during rewarming (51%, 49% and 54%, p = 0.077) up to 27% of the baseline level. At 8 mm tendon depth, cryotherapy preserved local oxygenation. Relative postcapillary venous tendon filling pressures were favourably reduced from 41 (11) to 31, 28 and 26 rU (−36%, p = 0.001) superficially and from 56 (11) to 45, 46 and 48 rU (−18%, p = 0.001) in deep capillary blood flow during cryotherapy, facilitating capillary venous clearance. Conclusion Intermittent cryotherapy of 3×10 min significantly decreases local Achilles tendon mid‐portion capillary blood flow by 71%. Within 2 min of rewarming, tendon oxygen saturation is re‐established following cryotherapy. Postcapillary venous filling pressures are reduced during cryotherapy, favouring capillary venous outflow of the healthy Achilles tendon. PMID:17138636

  7. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    PubMed

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  8. Precharged Pneumatic Soft Actuators and Their Applications to Untethered Soft Robots.

    PubMed

    Li, Yunquan; Chen, Yonghua; Ren, Tao; Li, Yingtian; Choi, Shiu Hong

    2018-06-20

    The past decade has witnessed tremendous progress in soft robotics. Unlike most pneumatic-based methods, we present a new approach to soft robot design based on precharged pneumatics (PCP). We propose a PCP soft bending actuator, which is actuated by precharged air pressure and retracted by inextensible tendons. By pulling or releasing the tendons, the air pressure in the soft actuator is modulated, and hence, its bending angle. The tendons serve in a way similar to pressure-regulating valves that are used in typical pneumatic systems. The linear motion of tendons is transduced into complex motion via the prepressurized bent soft actuator. Furthermore, since a PCP actuator does not need any gas supply, complicated pneumatic control systems used in traditional soft robotics are eliminated. This facilitates the development of compact untethered autonomous soft robots for various applications. Both theoretical modeling and experimental validation have been conducted on a sample PCP soft actuator design. A fully untethered autonomous quadrupedal soft robot and a soft gripper have been developed to demonstrate the superiority of the proposed approach over traditional pneumatic-driven soft robots.

  9. Coordinated development of the limb musculoskeletal system: Tendon and muscle patterning and integration with the skeleton.

    PubMed

    Huang, Alice H

    2017-09-15

    Functional movement and stability of the limb depends on an organized and fully integrated musculoskeletal system composed of skeleton, muscle, and tendon. Much of our current understanding of musculoskeletal development is based on studies that focused on the development and differentiation of individual tissues. Likewise, research on patterning events have been largely limited to the primary skeletal elements and the mechanisms that regulate soft tissue patterning, the development of the connections between tissues, and their interdependent development are only beginning to be elucidated. This review will therefore highlight recent exciting discoveries in this field, with an emphasis on tendon and muscle patterning and their integrated development with the skeleton and skeletal attachments. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Anatomic and isometric points on femoral attachment site of popliteus muscle-tendon complex for the posterolateral corner reconstruction.

    PubMed

    Yang, Jae-Hyuk; Lim, Hong Chul; Bae, Ji Hoon; Fernandez, Harry; Bae, Tae Soo; Wang, Joon Ho

    2011-10-01

    Descriptive laboratory study. The femoral anatomic insertion site and the optimal isometric point of popliteus tendon for posterolateral reconstruction are not well known. Purpose of this study was to determine the relative relationship between the femoral anatomic insertion and isometric point of popliteus muscle-tendon complex with the lateral epicondyle of femur. Thirty unpaired cadaveric knees were dissected to determine the anatomic femoral insertion of the popliteus tendon. The distance and the angle from the lateral epicondyle of femur to the center of the anatomic insertion of the popliteus tendon were measured using digital caliper and goniometer. Eight unpaired fresh cadaveric knees were examined to determine the optimal isometric point of femoral insertion of popliteus tendon using computer-controlled motion capture analysis system (Motion Analysis, CA, USA). Distances from targeted tibial tunnel for popliteus tendon reconstruction to the 35 points gained on the lateral surface of femur were recorded at 0, 30, 60, 90, and 120° knee flexion. A point with the least excursion (<2.0 mm) was determined as the isometric point. The center of anatomic insertion points and the optimal isometric point for the main fibers of popliteus tendon were found to be posterior and distal to the lateral epicondyle of femur. The distance from the lateral epicondyle of femur to the center of anatomic femoral insertion of popliteus tendon was 11.3 ± 1.2 mm (mean ± SD). The angle between long axis of femur and the line from lateral epicondyle of femur to anatomic femoral insertion of popliteus tendon was 31.4 ± 5.3°. The isometric points for the femoral insertion of popliteus muscle-tendon complex were situated posterior and distal to the lateral epicondyle in all 8 knees. The distance between the least excursion point and the lateral epicondyle was calculated as 10.4 ± 1.7 mm. The angle between the long axis of femur and the line from lateral epicondyle of femur to optimum isometric point of popliteus tendon was calculated as 41.3 ± 14.9°. The optimal isometric point for the femoral insertion of popliteus muscle-tendon complex is situated posterior and distal to the lateral epicondyle of femur. Femoral tunnel for "posterolateral corner sling procedure" should be placed at this point to achieve least amount of graft excursion during knee motion.

  11. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair.

    PubMed

    Budovec, Joseph J; Sudakoff, Gary S; Dzwierzynski, William W; Matloub, Hani S; Sanger, James R

    2006-04-01

    After the surgical repair of finger tendons finger range of motion may be limited by tendon rupture or adhesive scarring. Differentiating tendon rupture from adhesive scarring may be difficult clinically. Digital tendon sonography allows the evaluation of tendon integrity in a dynamic setting. Our objective was to determine if sonography could differentiate tendon rupture from adhesive scarring in patients who have had primary tendon repair. A retrospective review was performed of the radiographic, clinical, and surgical records of patients referred for finger sonography over a 2-year period. Twenty-eight digits in 21 patients were evaluated for finger tendon disruption after primary surgical repair. The diagnosis of complete tendon rupture was made when 1 or more of the following was identified: a gap separating the proximal and distal tendon margins, visualization of only the proximal tendon margin, or visualization of only the distal tendon margin. Adhesive scarring was diagnosed if the tendon appeared intact with abnormal peritendinous soft tissue abutting or partially encasing the tendon, with synovial sheath thickening, or with restricted tendon motion during dynamic evaluation. Sonography correctly identified tendon rupture or adhesive scarring in 27 of 28 digits with 1 false-positive case (sensitivity, 100%; specificity, 93%; positive-predictive value, 93%; negative-predictive value, 100%; accuracy, 96%). Sonography is an accurate modality for differentiating tendon rupture from adhesive scarring in patients with prior surgical tendon repair. Diagnostic, Level I.

  12. Open extensor tendon injuries: an epidemiologic study.

    PubMed

    Patillo, Dominic; Rayan, Ghazi M

    2012-01-01

    To report the epidemiology, mechanism, anatomical location, distribution, and severity of open extensor tendon injuries in the digits, hand, and forearm as well as the frequency of associated injuries to surrounding bone and soft tissue. Retrospective chart review was conducted for patients who had operative repair of open digital extensor tendon injuries in all zones within an 11-year period. Data was grouped according to patient characteristics, zone of injury, mechanism of injury, and presence of associated injury. Statistical analysis was used to determine the presence of relevant associations. Eighty-six patients with 125 severed tendons and 105 injured digits were available for chart reviews. Patients were predominantly males (83%) with a mean age of 34.2 years and the dominant extremity was most often injured (60%). The thumb was the most commonly injured (25.7%), followed by middle finger (24.8), whereas small finger was least affected (10.5%). Sharp laceration was the most common mechanism of injury (60%), and most of these occurred at or proximal to the metacarpophalangeal joints. Most saw injuries occurred distal to the metacarpophalangeal joint. Zone V was the most commonly affected in the fingers (27%) while zone VT was the most commonly affected in the thumb (69%). Associated injuries to bone and soft tissue occurred in 46.7% of all injuries with saw and crush/avulsions being predictive of fractures and damage to the underlying joint capsule. The extensor mechanism is anatomically complex, and open injuries to the dorsum of the hand, wrist, and forearm, especially of crushing nature and those inflicted by saws, must be thoroughly evaluated. Associated injuries should be ruled out in order to customize surgical treatment and optimize outcome.

  13. Slow Movements of Bio-Inspired Limbs

    NASA Astrophysics Data System (ADS)

    Babikian, Sarine; Valero-Cuevas, Francisco J.; Kanso, Eva

    2016-10-01

    Slow and accurate finger and limb movements are essential to daily activities, but the underlying mechanics is relatively unexplored. Here, we develop a mathematical framework to examine slow movements of tendon-driven limbs that are produced by modulating the tendons' stiffness parameters. Slow limb movements are driftless in the sense that movement stops when actuations stop. We demonstrate, in the context of a planar tendon-driven system representing a finger, that the control of stiffness suffices to produce stable and accurate limb postures and quasi-static (slow) transitions among them. We prove, however, that stable postures are achievable only when tendons are pretensioned, i.e., they cannot become slack. Our results further indicate that a non-smoothness in slow movements arises because the precision with which individual stiffnesses need to be altered changes substantially throughout the limb's motion.

  14. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    PubMed

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  15. Tendon transfer fixation: comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation.

    PubMed

    Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar

    2003-03-01

    Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.

  16. Simultaneous acute rotator cuff tear and distal biceps rupture in a strongman competitor.

    PubMed

    George, Michael S

    2010-04-01

    Acute rotator cuff tear is commonly associated with tearing of the proximal biceps tendon, but has never been reported to occur simultaneously with a distal biceps tendon rupture. A 38-year-old right-hand-dominant strongman competitor attempted a 300-pound overhead axle press and experienced immediate pain in the right shoulder and elbow. He had no known systemic risk factors for tendon ruptures including hyperparathyroidism, hemodialysis, alcoholism, rheumatoid arthritis, statin medications, fluoroquinolones, and steroid use.Right shoulder magnetic resonance imaging (MRI) showed a full-thickness supraspinatus tear with 3 cm of retraction. There was minimal fatty infiltration of the supraspinatus on the sagittal cuts consistent with acute rupture. The subscapularis was intact. The long head of the biceps tendon had mild medial subluxation but was completely within the bicipital groove. Right elbow MRI showed a complete distal biceps tendon rupture. Thirteen days after his injury, the patient underwent arthroscopic supraspinatus repair and proximal biceps tenodesis. Distal biceps tendon repair was performed using the modified 2-incision muscle-splitting technique. At 24-month follow-up, the patient was pain free and had returned to full activity including weightlifting but had not returned to strongman competition.This is the first report of simultaneous acute full thickness ruptures of the rotator cuff and distal biceps tendon. This case report underscores the importance of a complete physical examination and a high index of suspicion for additional concomitant injuries, particularly in athletes with unusually high stresses to the body. Copyright 2010, SLACK Incorporated.

  17. Different Sutures in the Surgical Treatment of Acute Closed Achilles Tendon Rupture.

    PubMed

    Ji, Yunhan; Ma, Xin; Wang, Xu; Huang, Jiazhang; Zhang, Chao; Chen, Li

    2015-12-01

    The aim was to compare the postoperative efficacy of the PDS II and Ethibond W4843 sutures in fresh, closed Achilles tendon rupture. With methods of random grouping (level of evidence II b), a total of 128 patients with fresh Achilles tendon rupture were operated on with PDS II or Ethibond W4843 suture. Postoperative objective examination and the American Orthopaedic Foot & Ankle Society (AOFAS) scoring system were used for the evaluation. Group A underwent 12-39 months of follow-up, for an average of 22 months. Group B underwent 12-37 months of follow-up, for an average of 23 months. The postoperative AOFAS score of group A within 3 months was 93 ± 9.6 points. One case exhibited re-rupture, five cases exhibited incision infection, one case manifested deep infection, and seven cases exhibited Achilles tendon adhesion. The postoperative AOFAS score of group B within 3 months was 97 ± 7.8 points. Eleven cases had incision infection, and 13 cases manifested Achilles tendon adhesion. Minimal differences were observed in the incision infection, re-rupture rate, and Achilles tendon adhesion in the study of the PDS II and Ethibond W4843 sutures. But, based on the AOFAS score and pain score, the Ethibond suture performed better.

  18. Ultrasonographic Findings of the Shoulder in Patients with Rheumatoid Arthritis and Comparison with Physical Examination

    PubMed Central

    Kim, Su Ho; Seo, Young-Il

    2007-01-01

    The objectives of this study were: 1) to identify the ultrasonographic (US) abnormalities and 2) to compare the findings of physical examination with US findings in rheumatoid arthritis (RA) patients with shoulder pain. We studied 30 RA patients. Physical examination was performed systemically as follows: 1) area of tenderness; 2) range of passive and active shoulder motion; 3) impingement tests; 4) maneuvers for determining the location of the tendon lesions. US investigations included the biceps, the supraspinatus, infraspinatus, and subscapularis tendons; the subacromial-subdeltoid bursa; and the glenohumeral and acromioclavicular joints. Thirty RA patients with 35 painful and 25 non-painful shoulders were examined. The range of motion affected the most by shoulder pain was abduction. The most frequent US finding of shoulder joint was effusion in the long head of the biceps tendon. Among the rotator cuff tendons, subscapularis was the most frequently involved. Tendon tear was also common among non-painful shoulders. Physical examination used for the diagnosis of shoulder pain had low sensitivity and specificity for detecting abnormalities in the rheumatoid shoulder joint. In conclusion, US abnormalities showed frequent tendon tears in our RA patients. Physical examination had low sensitivity and specificity for detecting rotator cuff tear in the rheumatoid shoulder joint. PMID:17728506

  19. Incidence and Association of CT Findings of Ankle Tendon Injuries in Patients Presenting With Ankle and Hindfoot Fractures.

    PubMed

    Golshani, Ashkahn; Zhu, Liang; Cai, Chunyan; Beckmann, Nicholas M

    2017-02-01

    Tendon injuries are a commonly encountered finding in ankle CT examinations performed for fractures. This study was designed to identify the incidence and associations of tendon injuries in ankle CT examinations performed for fractures. A retrospective review was performed of 410 patients who underwent ankle CT during a 6-year period. Tendon injuries were common, seen in 25% of all ankle CT examinations. Tendon subluxation-dislocation accounted for most of the tendon injuries (77 of 196 total injuries). Pilon fractures carried 2.2 times increased risk of tibialis posterior tendon injury (p = 0.0094). Calcaneus fractures carried 11.86 times increased risk of peroneus brevis tendon and 10.71 times increased risk of peroneus longus tendon injury (p < 0.0001). Calcaneus fractures also carried 5.21 times increased risk of flexor hallucis longus tendon injury (p = 0.0024). Talus fracture was associated with injury to all flexor compartment tendons. Talus fractures carried 3.43 times increased risk of tibialis posterior tendon injury (p < 0.0001), 4.51 times increased risk of flexor digitorum longus tendon injury (p = 0.0005), and 6.97 times increased risk of flexor hallucis longus tendon injury (p < 0.0001). Calcaneal fractures are prone to peroneal tendon injury, and talus fractures are prone to flexor tendon injury. In patients with pilon fractures, it is important to look for tibialis posterior tendon injury, specifically for entrapment. Overall, the most common type of injury is tendon malalignment, so it is imperative to know the normal tendon paths and associated bony landmarks to identify tendon injury.

  20. Isokinetic strength and endurance after percutaneous and open surgical repair of Achilles tendon ruptures.

    PubMed

    Goren, David; Ayalon, Moshe; Nyska, Meir

    2005-04-01

    Reports on complete spontaneous Achilles tendon ruptures and associated treatment have become more frequent in the literature in the past two decades, as has the request for treatments that enable the finest possible functional recovery. The best available treatment is a matter of considerable controversy in the literature. The purpose of this study was to compare the isokinetic strength and endurance of the plantarflexor muscle-tendon unit in subjects who sustained rupture of the Achilles tendon and underwent either open surgery or closed percutaneous repair of the Achilles tendon. Twenty patients (18 males, 2 females) with spontaneous ruptures of the Achilles tendon were included in this study. Ten patients were treated by open surgery, and 10 patients were treated percutaneously. All patients had ruptured their Achilles tendon more than 6 months before the study, and all of the ruptures occurred 3.5 years or less before the day of the testing. All patients underwent an oriented physical examination. An isokinetic Biodex dynamometer (Biodex Medical System, Shirley, NY) was used to measure ankle joint angle, and in plantarflexion to calculate the torque at the ankle joint (Newton/meter), and the average work (jouls) for both maximal power and endurance. Each measurement was compared to the normal ankle. Biodex dynamometer evaluations at 90 deg/sec demonstrated a significant difference of maximal voluntary plantarflexor torque, endurance performance and range of motion at the ankle joint between the involved and uninvolved sides in patients treated by either mode of treatment. Yet, no statistically significant differences were revealed for the parameters mentioned above between the subjects that were treated either percutaneously or by an open surgery. In functional terms, the biomechanical outcomes of open surgery and percutaneous repair for acute ruptures of the Achilles tendon are both effective.

  1. Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems.

    PubMed

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-04-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable, and when combined with readily available autologous cells, may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stem cells (ADSCs) that were cultured on a poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to a PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker, was upregulated seven- to eightfold at 1 week with GDF-5 treatment when cultured on a 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by fourfold starting at 1 week on treatment with 100 ng mL(-1) GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on a PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration.

  2. Tendon tissue engineering: Adipose 1 derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems

    PubMed Central

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-01-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable when combined with readily available autologous cells may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stromal cells (ADSCs) that were cultured on poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker was upregulated 7 – 8 fold at 1 week with GDF-5 treatment when cultured on 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by 4 fold starting at 1 week on treatment with 100ng/mL GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration. PMID:21436509

  3. Tensile properties of a morphologically split supraspinatus tendon.

    PubMed

    Matsuhashi, Tomoya; Hooke, Alexander W; Zhao, Kristin D; Goto, Akira; Sperling, John W; Steinmann, Scott P; An, Kai-Nan

    2014-07-01

    The supraspinatus tendon consists morphologically of two sub-regions, anterior and posterior. The anterior sub-region is thick and tubular while the posterior is thin and strap-like. The purpose of this study was to compare the structural and mechanical properties of the anterior and posterior sub-regions of the supraspinatus tendon. The supraspinatus tendons from seven human cadaveric shoulders were morphologically divided into the anterior and posterior sub-regions. Length, width, and thickness were measured. A servo-hydraulic testing machine (MTS Systems Corporation, Minneapolis, MN) was used for tensile testing. The maximal load at failure, modulus of elasticity and ultimate tendon stress were calculated. Repeated measures were used for statistical comparisons. The mean anterior tendon cross-sectional area was 47.3 mm(2) and the posterior was 32.1 mm(2) . Failure occurred most often at the insertion site: anterior (5/7) and posterior (6/7). All parameters of the anterior sub-region were significantly greater than those of the posterior sub-region. The moduli of elasticity at the insertion site were 592.4 MPa in the anterior sub-region and 217.7 MPa in the posterior (P = 0.01). The ultimate failure loads were 779.2 N in the anterior sub-region and 335.6 N in the posterior (P = 0.003). The ultimate stresses were 22.1 MPa in the anterior sub-region and 11.6 MPa in the posterior (P = 0.008). We recognized that the anterior and posterior sub-regions of the SSP tendon have significantly different mechanical properties. In a future study, we need to evaluate how best to repair an SSP tendon considering these region-specific properties. Copyright © 2013 Wiley Periodicals, Inc.

  4. Repair of distal biceps tendon rupture with the Biotenodesis screw.

    PubMed

    Khan, W; Agarwal, M; Funk, L

    2004-04-01

    Distal biceps tendon ruptures are uncommon injuries with only around 300 cases reported in the literature. Current management tends to favour anatomical reinsertion of the tendon into the radial tuberosity, especially in young and active individuals. These injuries are commonly repaired using either a single anterior incision with suture anchors or the Boyd-Anderson dual incision technique. We report the use of a bioabsorbable interference screw for the repair of distal biceps tendon rupture using a minimal incision technique. In this technique the avulsed tendon and a bioabsorbable screw are secured in a drill hole on the radial tuberosity using whip stitch and fibre wire sutures according to Biotenodesis system guidelines. The technique described requires minimal volar dissection that is associated with a reduced number of synostosis and posterior interosseous nerve injuries. The bioabsorbable interference screw has all the advantages of being biodegradable and has been shown to have greater pullout strength than suture anchors. It is also a reasonable alternative to titanium screws in terms of primary fixation strength. The strong fixation provided allows early active motion and return to previous activities as seen in our case.

  5. Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons.

    PubMed

    Schneebeli, Alessandro; Del Grande, Filippo; Vincenzo, Gabriele; Cescon, Corrado; Clijsen, Ron; Biordi, Fulvio; Barbero, Marco

    2016-08-01

    To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.

  6. Comparison of shear wave velocity measurements assessed with two different ultrasound systems in an ex-vivo tendon strain phantom.

    PubMed

    Rosskopf, Andrea B; Bachmann, Elias; Snedeker, Jess G; Pfirrmann, Christian W A; Buck, Florian M

    2016-11-01

    The purpose of this study is to compare the reliability of SW velocity measurements of two different ultrasound systems and their correlation with the tangent traction modulus in a non-static tendon strain model. A bovine tendon was fixed in a custom-made stretching device. Force was applied increasing from 0 up to 18 Newton. During each strain state the tangent traction modulus was determined by the stretcher device, and SW velocity (m/s) measurements using a Siemens S3000 and a Supersonic Aixplorer US machine were done for shear modulus (kPa) calculation. A strong significant positive correlation was found between SW velocity assessed by the two ultrasound systems and the tangent traction modulus (r = 0.827-0.954, p < 0.001), yet all SW velocity-based calculations underestimated the reference tissue tangent modulus. Mean difference of SW velocities with the S3000 was 0.44 ± 0.3 m/s (p = 0.002) and with the Aixplorer 0.25 ± 0.3 m/s (p = 0.034). Mean difference of SW velocity between the two US-systems was 0.37 ± 0.3 m/s (p = 0.012). In conclusion, SW velocities are highly dependent on mechanical forces in the tendon tissue, but for controlled mechanical loads appear to yield reproducible and comparable measurements using different US systems.

  7. Ultrasound elasticity imaging of human posterior tibial tendon

    NASA Astrophysics Data System (ADS)

    Gao, Liang

    Posterior tibial tendon dysfunction (PTTD) is a common degenerative condition leading to a severe impairment of gait. There is currently no effective method to determine whether a patient with advanced PTTD would benefit from several months of bracing and physical therapy or ultimately require surgery. Tendon degeneration is closely associated with irreversible degradation of its collagen structure, leading to changes to its mechanical properties. If these properties could be monitored in vivo, it could be used to quantify the severity of tendonosis and help determine the appropriate treatment. Ultrasound elasticity imaging (UEI) is a real-time, noninvasive technique to objectively measure mechanical properties in soft tissue. It consists of acquiring a sequence of ultrasound frames and applying speckle tracking to estimate displacement and strain at each pixel. The goals of my dissertation were to 1) use acoustic simulations to investigate the performance of UEI during tendon deformation with different geometries; 2) develop and validate UEI as a potentially noninvasive technique for quantifying tendon mechanical properties in human cadaver experiments; 3) design a platform for UEI to measure mechanical properties of the PTT in vivo and determine whether there are detectable and quantifiable differences between healthy and diseased tendons. First, ultrasound simulations of tendon deformation were performed using an acoustic modeling program. The effects of different tendon geometries (cylinder and curved cylinder) on the performance of UEI were investigated. Modeling results indicated that UEI accurately estimated the strain in the cylinder geometry, but underestimated in the curved cylinder. The simulation also predicted that the out-of-the-plane motion of the PTT would cause a non-uniform strain pattern within incompressible homogeneous isotropic material. However, to average within a small region of interest determined by principal component analysis (PCA) would improve the estimation. Next, UEI was performed on five human cadaver feet mounted in a materials testing system (MTS) while the PTT was attached to a force actuator. A portable ultrasound scanner collected 2D data during loading cycles. Young's modulus was calculated from the strain, loading force and cross sectional area of the PTT. Average Young's modulus for the five tendons was (0.45+/-0.16GPa) using UEI. This was consistent with simultaneous measurements made by the MTS across the whole tendon (0.52+/-0.18GPa). We also calculated the scaling factor (0.12+/-0.01) between the load on the PTT and the inversion force at the forefoot, a measurable quantity in vivo. This study suggests that UEI could be a reliable in vivo technique for estimating the mechanical properties of the human PTT. Finally, we built a custom ankle inversion platform for in vivo imaging of human subjects (eight healthy volunteers and nine advanced PTTD patients). We found non-linear elastic properties of the PTTD, which could be quantified by the slope between the elastic modulus (E) and the inversion force (F). This slope (DeltaE/DeltaF), or Non-linear Elasticity Parameter (NEP), was significantly different for the two groups: 0.16+/-0.20 MPa/N for healthy tendons and 0.45+/-0.43 MPa/N for PTTD tendons. A receiver operating characteristic (ROC) curve revealed an area under the curve (AUC) of 0.83+/-0.07, which indicated that the classifier system is valid. In summary, the acoustic modeling, cadaveric studies, and in vivo experiments together demonstrated that UEI accurately quantifies tendon mechanical properties. As a valuable clinical tool, UEI also has the potential to help guide treatment decisions for advanced PTTD and other tendinopathies.

  8. The structure of interfibrillar proteoglycan bridges (‘shape modules’) in extracellular matrix of fibrous connective tissues and their stability in various chemical environments

    PubMed Central

    SCOTT, JOHN E.; THOMLINSON, ALISON M.

    1998-01-01

    Collagen fibrils in extracellular matrices of connective tissues (tendon, cornea, etc.) are bridged and linked by the anionic glycosaminoglycans (AGAGs) of the small proteoglycans (decoron, etc.). It was proposed that these bridges and ties maintain the collagen fibril dispositions in relation to each other, helping to define tissue shape, and hence called shape modules. This investigation describes chemical and physicochemical conditions in which these structures are stable and what treatments cause their disruption. The effects on fixed and unfixed sections of tendon, cornea, lung and ear from rat, mouse and rabbit of pH, electrolyte concentration, EDTA, mercaptoethanol, hydrogen peroxide, free radicals, periodate, acetylation, urea, nonionic detergent and organic solvents were assessed by staining with Cupromeronic blue or Alcec blue in CEC techniques to localise AGAG bridges or their disintegration products. Ca2+ was not involved in the structures, oxidation/reduction had no effect and Triton X100, a nonionic detergent did not damage them. They were stable between pH 4.5 and 9.5. Periodate as a glycol-cleaving reagent did not affect them. High concentrations of urea (>2.0 m) and MgCl2 (0.5 m) disrupted the tissues. The combination of Triton and urea at concentrations too low to cause damage separately was disruptive. Free radicals in periodate solutions were damaging. Organic solvents caused collapse and rearrangements of the AGAG filaments. Acetylation caused considerable disruption of shape modules. Dermochondan but not keratan sulphate AGAGs were removed by treatment with NaOH. After fixing with glutaraldehyde only free radical and NaOH treatments were severely disruptive of shape modules. The results are compatible with a previously proposed structure for the shape modules, stabilised by hydrophobic and hydrogen bonding. PMID:9688505

  9. The effect of seprafilm on adhesion formation and tendon healing after flexor tendon repair in chicken.

    PubMed

    Yilmaz, Erhan; Avci, Mustafa; Bulut, Mehmet; Kelestimur, Halidun; Karakurt, Lokman; Ozercan, Ibrahim

    2010-03-01

    Adhesion of the tendon, which can occur during healing of tendon repair, is negatively affected by the outcome of surgery. In this experimental study, we sought to prevent adhesion of the tendon, and determined the mechanical stiffness of repair tissue by wrapping sodium hyaluronate and carboxymethylcellulose (Seprafilm; Genzyme, Cambridge, Massachusetts) around the repaired tendon segments. The study group comprised 2 groups of 20 chickens. In group I, the right gastrocnemius tendons of the chickens were cut smoothly, and after tendon and sheath repair, the skin was sutured. In group II, the right gastrocnemius tendons of the chickens were cut, the tendons were repaired, and before skin closure, Seprafilm was wrapped around the repaired tendon segments. Plastic splints were used for holding the chickens' ankles in a neutral position, and they were allowed weight bearing for 8 weeks. In group II, anatomic space between the tendon-sheath and tendon was clear and the tendon-sheath complex was sliding easily around the repaired tendon segment, and this complex was more functional both biomechanically and histologically. Also, the Seprafilm-applied tendons (group II) were observed to be biomechanically more resistant to the tensile forces in group I. Seprafilm is an easily applied interpositional material that can be used safely to prevent adhesion during the tendon healing process. Copyright 2010, SLACK Incorporated.

  10. Minimally Invasive Posterior Hamstring Harvest

    PubMed Central

    Wilson, Trent J.; Lubowitz, James H.

    2013-01-01

    Autogenous hamstring harvesting for knee ligament reconstruction is a well-established standard. Minimally invasive posterior hamstring harvest is a simple, efficient, reproducible technique for harvest of the semitendinosus or gracilis tendon or both medial hamstring tendons. A 2- to 3-cm longitudinal incision from the popliteal crease proximally, in line with the semitendinosus tendon, is sufficient. The deep fascia is bluntly penetrated, and the tendon or tendons are identified. Adhesions are dissected. Then, an open tendon stripper is used to release the tendon or tendons proximally; a closed, sharp tendon stripper is used to release the tendon or tendons from the pes. Layered, absorbable skin closure is performed, and the skin is covered with a skin sealant, bolster dressing, and plastic adhesive bandage for 2 weeks. PMID:24266003

  11. Tendon biomechanics and mechanobiology - a mini-review of basic concepts and recent advancements

    PubMed Central

    Wang, James H-C.; Guo, Qianping; Li, Bin

    2011-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechano-responsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechano-adaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into non-tenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols in order to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma (PRP), which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. PMID:21925835

  12. Tendon biomechanics and mechanobiology--a minireview of basic concepts and recent advancements.

    PubMed

    Wang, James H-C; Guo, Qianping; Li, Bin

    2012-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechanoresponsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechanoadaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into nontenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma, which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  13. Tendinopathy: injury, repair, and current exploration

    PubMed Central

    Lipman, Kelsey; Wang, Chenchao; Ting, Kang; Soo, Chia; Zheng, Zhong

    2018-01-01

    Both acute and chronic tendinopathy result in high morbidity, requiring management that is often lengthy and expensive. However, limited and conflicting scientific evidence surrounding current management options has presented a challenge when trying to identify the best treatment for tendinopathy. As a result of shortcomings of current treatments, response to available therapies is often poor, resulting in frustration in both patients and physicians. Due to a lack of understanding of basic tendon-cell biology, further scientific investigation is needed in the field for the development of biological solutions. Optimization of new delivery systems and therapies that spatially and temporally mimic normal tendon physiology hold promise for clinical application. This review focuses on the clinical importance of tendinopathy, the structure of healthy tendons, tendon injury, and healing, and a discussion of current approaches for treatment that highlight the need for the development of new nonsurgical interventions. PMID:29593382

  14. Development of high shrinkage polyethylene terephthalate (PET) shape memory polymer tendons for concrete crack closure

    NASA Astrophysics Data System (ADS)

    Teall, Oliver; Pilegis, Martins; Sweeney, John; Gough, Tim; Thompson, Glen; Jefferson, Anthony; Lark, Robert; Gardner, Diane

    2017-04-01

    The shrinkage force exerted by restrained shape memory polymers (SMPs) can potentially be used to close cracks in structural concrete. This paper describes the physical processing and experimental work undertaken to develop high shrinkage die-drawn polyethylene terephthalate (PET) SMP tendons for use within a crack closure system. The extrusion and die-drawing procedure used to manufacture a series of PET tendon samples is described. The results from a set of restrained shrinkage tests, undertaken at differing activation temperatures, are also presented along with the mechanical properties of the most promising samples. The stress developed within the tendons is found to be related to the activation temperature, the cross-sectional area and to the draw rate used during manufacture. Comparisons with commercially-available PET strip samples used in previous research are made, demonstrating an increase in restrained shrinkage stress by a factor of two for manufactured PET filament samples.

  15. Human Grasp Assist Device Soft Goods

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Bergelin, Bryan (Inventor); Bridgwater, Lyndon B. J. (Inventor); Bibby, Heather (Inventor); Schroeder, Judy (Inventor); Linn, Douglas Martin (Inventor); Erkkila, Craig (Inventor)

    2015-01-01

    A grasp assist system includes a glove and a flexible sleeve. The glove includes a digit such as a finger or thumb, a force sensor configured to measure a grasping force applied to an object by an operator wearing the glove, and adjustable phalange rings positioned with respect to the digit. A saddle is positioned with respect to the finger. A flexible tendon is looped at one end around the saddle. A conduit contains the tendon. A conduit anchor secured within a palm of the glove receives the conduit. The sleeve has pockets containing an actuator assembly connected to another end of the tendon and a controller. The controller is in communication with the force sensor, and calculates a tensile force in response to the measured grasping force. The controller commands the tensile force from the actuator assembly to tension the tendon and thereby move the finger.

  16. Control of a Glove-Based Grasp Assist Device

    NASA Technical Reports Server (NTRS)

    Bergelin, Bryan J (Inventor); Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Linn, Douglas Martin (Inventor); Sanders, Adam M (Inventor); Askew, R. Scott (Inventor); Laske, Evan (Inventor); Ensley, Kody (Inventor)

    2015-01-01

    A grasp assist system includes a glove and sleeve. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. The glove contains a tendon connected at a first end to the digit. The sleeve has an actuator assembly connected to a second end of the tendon and a controller in communication with the sensor. The controller includes a configuration module having selectable operating modes and a processor that calculates a tensile force to apply to the tendon for each of the selectable operating modes to assist the grasping force in a manner that differs for each of the operating modes. A method includes measuring the grasping force, selecting the mode, calculating the tensile force, and applying the tensile force to the tendon using the actuator assembly.

  17. Method and apparatus for production of subsea hydrocarbon formations

    DOEpatents

    Blandford, Joseph W.

    1994-01-01

    A well tender system for controlling, separating, storing and offloading well fluids produced from subsea hydrocarbon formations. The system comprises a vertically aligned series of tethered cylindrical tanks which are torsionally stabilized by flexible catenary production riser and export riser bundles, and serviced by separate catenary pipe bundles. Piles are secured to the seabed, each pile assembly being pivotally connected to a lower rigid tendon, which is in turn connected to tendons arranged about the periphery of the interconnected cylindrical tanks.

  18. Method and apparatus for production of subsea hydrocarbon formations

    DOEpatents

    Blandford, Joseph W.

    1992-01-01

    A well tender system for controlling, separating, storing and offloading well fluids produced from subsea hydrocarbon formations. The system comprises a vertically aligned series of tethered cylindrical tanks which are torsionally stabilized by flexible catenary production riser and expert riser bundles, and serviced by separate catenary pipe bundles. Piles are secured to the seabed, each pile assembly being pivotally connected to a lower rigid tendon, which is in turn connected to tendons arranged about the periphery of the interconnected cylindrical tanks.

  19. Infrared fiber optic probes for evaluation of musculoskeletal tissue pathology

    NASA Astrophysics Data System (ADS)

    Padalkar, Mugdha; McGoverin, Cushla; Onigbanjo, Quam; Spencer, Richard; Barbash, Scott; Kropf, Eric; Pleshko, Nancy

    2014-03-01

    Musculoskeletal pathology of the knee commonly occurs with aging and as a result of injury. The incidence of anterior cruciate ligament (ACL) injuries continues to increase annually, and may precede the eventual onset of osteoarthritis (OA), a debilitating and prevalent disease characterized by cartilage degeneration. Early detection of OA remains elusive, with current imaging methods lacking adequate sensitivity to detect early pathologic cartilage changes. We used mid- and near- infrared (IR) spectroscopy through arthroscopic-based fiber-optic devices to assess cartilage damage and differentiate tendon from ligament. Mid-IR spectroscopy is characterized by distinct bands and low penetration depth (< 10 μm) and near-IR spectroscopy is characterized by complex overlapping bands and greater penetration depths (< 1 cm). We have found that combined mid- and near-IR analysis greatly extends the information available through either in the analysis of soft tissues, including cartilage, ligaments and tendons. We discuss here basic science studies and the potential for translation to clinical research with novel arthroscopic probes.

  20. [Anatomy typological and clinical parallels in case of disturbance of soft tissue formations of shoulder girdle].

    PubMed

    Volkov, A V; Shutov, Iu M; Shutova, M Z

    2012-01-01

    The influence of anthropology on topographical anatomical structure peculiarities of soft tissue formations of shoulder girdle has been investigated. The dependence of anatomical structure and topography of muscles, ligaments, tendon sheaths, synovial bursae, rotator cuffs on patient's body constitution type has been examined. The influence of a somatotype on topical damage of soft tissue structures of shoulder girdle has been proved. The so-called "holes" or weak areas, joint capsules, places where ligaments attach to bones and cartilages, where vascular formations also take place have been revealed. It is in these areas that degenerative inflammatory process begins. First of all this process influences hemolymph circulation, then it results in disturbance in production and resorption of synovial fluid and causes destructive processes in ligaments, tendons and osteochondral tissue. Due to research the ability to conduct differential diagnosis has been determined, methods of modality treatment and prevention of periarticular tissue diseases have been optimized.

  1. A study of 60 patients with percutaneous trigger finger releases: clinical and ultrasonographic findings.

    PubMed

    Gulabi, D; Cecen, G S; Bekler, H I; Saglam, F; Tanju, N

    2014-09-01

    We present the clinical results and ultrasonographic findings of 61 trigger digits treated with percutaneous A1 pulley release. An endoscopic carpal tunnel knife was used for the release in the outpatient department. The mean follow-up period was 3.5 months. A total of 55 digits (90%) had complete relief of their triggering postoperatively. Six digits (10%) had Grade 2 triggering clinically in the early postoperative period.The complications included six cases of insufficient release (10%), scar sensitivity in one patient, short-term hypoaesthesia in three digits (5%), and flexor tendon laceration noted on postoperative ultrasonography in eight digits (13%). No neurovascular damage was noted on the postoperative ultrasonography. Ultrasonograpy provides information about tendon laceration and changes in thickness of the pulleys and confirm A1 pulley release after surgery, but it does not alter clinical decision-making. We believe that pre- and postoperative ultrasonograpy does not need to be included as a routine examination. © The Author(s) 2014.

  2. Transcription factor EGR1 directs tendon differentiation and promotes tendon repair

    PubMed Central

    Guerquin, Marie-Justine; Charvet, Benjamin; Nourissat, Geoffroy; Havis, Emmanuelle; Ronsin, Olivier; Bonnin, Marie-Ange; Ruggiu, Mathilde; Olivera-Martinez, Isabel; Robert, Nicolas; Lu, Yinhui; Kadler, Karl E.; Baumberger, Tristan; Doursounian, Levon; Berenbaum, Francis; Duprez, Delphine

    2013-01-01

    Tendon formation and repair rely on specific combinations of transcription factors, growth factors, and mechanical parameters that regulate the production and spatial organization of type I collagen. Here, we investigated the function of the zinc finger transcription factor EGR1 in tendon formation, healing, and repair using rodent animal models and mesenchymal stem cells (MSCs). Adult tendons of Egr1–/– mice displayed a deficiency in the expression of tendon genes, including Scx, Col1a1, and Col1a2, and were mechanically weaker compared with their WT littermates. EGR1 was recruited to the Col1a1 and Col2a1 promoters in postnatal mouse tendons in vivo. Egr1 was required for the normal gene response following tendon injury in a mouse model of Achilles tendon healing. Forced Egr1 expression programmed MSCs toward the tendon lineage and promoted the formation of in vitro–engineered tendons from MSCs. The application of EGR1-producing MSCs increased the formation of tendon-like tissues in a rat model of Achilles tendon injury. We provide evidence that the ability of EGR1 to promote tendon differentiation is partially mediated by TGF-β2. This study demonstrates EGR1 involvement in adult tendon formation, healing, and repair and identifies Egr1 as a putative target in tendon repair strategies. PMID:23863709

  3. Surface Modification Counteracts Adverse Effects Associated with Immobilization after Flexor Tendon Repair

    PubMed Central

    Zhao, Chunfeng; Sun, Yu-Long; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2012-01-01

    SUMMARY Although post-rehabilitation is routinely performed following flexor tendon repair, in some clinical scenarios post-rehabilitation must be delayed. We investigated modification of the tendon surface using carbodiimide derivatized hyaluronic acid and lubricin (cd-HA-Lub) to maintain gliding function following flexor tendon repair with postoperative immobilization in a in vivo canine model. Flexor digitorum profundus tendons from the 2nd and 5th digits of one forepaw of six dogs were transected and repaired. One tendon in each paw was treated with cd-HA-Lub; the other repaired tendon was not treated. Following tendon repair, a forearm cast was applied to fully immobilize the operated forelimb for 10 days, after which the animals were euthanized. Digit normalized work of flexion (nWOF) and tendon gliding resistance were assessed. The nWOF of the FDP tendons treated with cd-HA-Lub was significantly lower than the nWOF of the untreated tendons (p < 0.01). The gliding resistance of cd-HA-Lub treated tendons was also significantly lower than that of the untreated tendons (p < 0.05). Surface treatment with cd-HA-Lub following flexor tendon repair provides an opportunity to improve outcomes for patients in whom the post-operative therapy must be delayed after flexor tendon repair. PMID:22714687

  4. Biochemical and Anatomical Characteristics of Dolphin Muscles.

    DTIC Science & Technology

    1984-01-01

    the Bioengineering Branch (Code 5143) of the Naval Ocean Systems Center and the Kinesiology Department of the University of California, Los Angeles...such a sample. TENDON ANALYSES The biochemistry of the dolphin tendon suggests that this tissue is well adapted to withstand large forces and significant...neuromuscular physiology, connective tissue, and muscle biochemistry . A detailed proposal outlining the goals, approach, milestones, and costs for

  5. Frequency of inflammatory-like MR imaging findings in asymptomatic fingers of healthy volunteers.

    PubMed

    Agten, Christoph A; Rosskopf, Andrea B; Jonczy, Maciej; Brunner, Florian; Pfirrmann, Christian W A; Buck, Florian M

    2018-02-01

    To describe the frequency of inflammatory-like findings on MR imaging in asymptomatic volunteers and compare them with patients with known rheumatoid arthritis and psoriatic arthritis. MR images of fingers in 42 asymptomatic volunteers and 33 patients with rheumatoid/psoriatic arthritis were analyzed. The Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid/Psoriatic Arthritis MRI Scoring System (RAMRIS/PsAMRIS) and tenosynovitis scoring system were used to assess: bone marrow edema (BME), erosions, tendon sheath fluid/tenosynovitis, joint effusion, and soft-tissue edema. Findings and scores were compared between volunteers and patients. Inter-reader agreement was calculated (intraclass correlation coefficients, ICC). In volunteers, tendon sheath fluid was very common in at least one location (42/42 volunteers for reader 1, 34/42 volunteers for reader 2). BME, erosions, joint effusion, and soft-tissue edema were absent (except one BME in the 3rd proximal phalanx for reader 1). Tendon sheath fluid scores in volunteers and tenosynovitis scores in patients were high (reader 1, 7.17 and 5.39; reader 2, 2.31 and 5.45). Overall, inter-reader agreement was substantial (ICC = 0.696-0.844), except for tendon sheath fluid (ICC = 0.258). Fluid in the finger flexor tendon sheaths may be a normal finding and without gadolinium administration should not be interpreted as tenosynovitis. Bone marrow edema, erosions, joint effusion, and soft-tissue edema in the fingers most likely reflect pathology if present.

  6. Septic flexor tendonitis and suspensory desmitis in an alpaca.

    PubMed

    Hunter, Barbara G; Semevolos, Stacy A

    2013-07-01

    A 2-year-old male Suri alpaca was referred for evaluation of severe right forelimb lameness of 2 weeks' duration following a traumatic episode. Examination of the distal aspect of the metacarpus revealed 4 wounds exuding purulent material. On weight bearing, the metacarpophalangeal joint was severely hyperextended with the palmar surface touching the ground. Ultrasonography of the palmar surface of the metacarpus revealed desmitis of the proximal suspensory ligament, a large core lesion of the deep digital flexor tendon at mid-metacarpus, and complete loss of fiber pattern within the deep digital flexor tendon and lateral aspect of the superficial digital flexor tendon distally. The alpaca was treated systemically with antimicrobials and anti-inflammatory drugs and underwent repeated antimicrobial intraosseous regional limb perfusion. A bandage and splint were applied to stabilize the affected forelimb in an anatomically correct position, and the alpaca underwent prolonged stall confinement. At the time of hospital discharge 5 days after initial evaluation, clinical evidence of infection at the wound sites was absent. Three months following treatment, the alpaca was moving freely in a small paddock and had moderate hyperextension of the metacarpophalangeal joint. Treatment of septic flexor tendonitis and suspensory desmitis with antimicrobial intraosseous regional limb perfusion in combination with systemic treatment with antimicrobials and orthopedic support resulted in an excellent outcome in this alpaca. Antimicrobial intraosseous regional limb perfusion is simple to perform and has the potential to be beneficial in the treatment of infections in the distal portion of a limb in camelids.

  7. The effects of sectioning the spring ligament on rearfoot stability and posterior tibial tendon efficiency.

    PubMed

    Jennings, Meagan M; Christensen, Jeffery C

    2008-01-01

    Posterior tibial tendon insufficiency has been implicated as a cause of adult acquired flatfoot. Multiple theories are debated as to whether or not a flatfoot deformity develops secondary to insufficiency of the posterior tibial tendon or of the ligamentous structures such as the spring ligament complex. This cadaveric study was undertaken in an attempt to determine the effect that sectioning the spring ligament complex has on foot stability, and whether engagement of the posterior tibial tendon would be able to compensate for the loss of the spring ligament complex. A 3-dimensional kinematic system and a custom-loading frame were used to quantify rotation about the talus, navicular, and calcaneus in 5 cadaveric specimens, before and after sectioning the spring ligament complex, while incremental tension was applied to the posterior tibial tendon. This study demonstrated that sectioning the spring ligament complex created instability in the foot for which the posterior tibial tendon was unable to compensate. Sectioning the spring ligament complex also produced significant changes in talar, navicular, and calcaneal rotations. During simulated midstance, the navicular plantarflexed, adducted, and everted; the talar head plantarflexed, adducted, and inverted; and the calcaneus plantarflexed, abducted, and everted, after sectioning the spring ligament complex. The results of this study indicate that the spring ligament complex is the major stabilizer of the arch during midstance and that the posterior tibial tendon is incapable of fully accommodating for its insufficiency, suggesting that the spring ligament complex should be evaluated and, if indicated, repaired in flatfoot reconstruction. 5.

  8. Decorin expression is important for age-related changes in tendon structure and mechanical properties

    PubMed Central

    Dunkman, Andrew A.; Buckley, Mark R.; Mienaltowski, Michael J.; Adams, Sheila M.; Thomas, Stephen J.; Satchell, Lauren; Kumar, Akash; Pathmanathan, Lydia; Beason, David P.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2013-01-01

    The aging population is at an increased risk of tendon injury and tendinopathy. Elucidating the molecular basis of tendon aging is crucial to understanding the age-related changes in structure and function in this vulnerable tissue. In this study, the structural and functional features of tendon aging are investigated. In addition, the roles of decorin and biglycan in the aging process were analyzed using transgenic mice at both mature and aged time points. Our hypothesis is that the increase in tendon injuries in the aging population is the result of altered structural properties that reduce the biomechanical function of the tendon and consequently increase susceptibility to injury. Decorin and biglycan are important regulators of tendon structure and therefore, we further hypothesized that decreased function in aged tendons is partly the result of altered decorin and biglycan expression. Biomechanical analyses of mature (day 150) and aged (day 570) patellar tendons revealed deteriorating viscoelastic properties with age. Histology and polarized light microscopy demonstrated decreased cellularity, alterations in tenocyte shape, and reduced collagen fiber alignment in the aged tendons. Ultrastructural analysis of fibril diameter distributions indicated an altered distribution in aged tendons with an increase of large diameter fibrils. Aged wild type tendons maintained expression of decorin which was associated with the structural and functional changes seen in aged tendons. Aged patellar tendons exhibited altered and generally inferior properties across multiple assays. However, decorin-null tendons exhibited significantly decreased effects of aging compared to the other genotypes. The amelioration of the functional deficits seen in the absence of decorin in aged tendons was associated with altered tendon fibril structure. Fibril diameter distributions in the decorin-null aged tendons were comparable to those observed in the mature wild type tendon with the absence of the subpopulation containing large diameter fibrils. Collectively, our findings provide evidence for age-dependent alterations in tendon architecture and functional activity, and further show that lack of stromal decorin attenuates these changes. PMID:23178232

  9. Robert Jones Lecture, 1979. The reconstructive surgery of flaccid paralysis.

    PubMed Central

    Brooks, D.

    1982-01-01

    A flaccid paralysis results from damage to any part of the lower motor neurone, from destruction of the anterior horn cell by poliomyelitis to injury of the peripheral axon by trauma or disease. Reconstructive surgery can do much to alleviate the residual paralysis. The indications and timing for surgery are considered. Certain well-tried operative techniques are described, from tendon transplantation to arthrodeses of joints, and the relative merits of each procedure are evaluated and placed in perspective. PMID:7092088

  10. Use of Tourniquets and their Effects on Limb Function in the Modern Combat Environment

    DTIC Science & Technology

    2010-03-01

    pressure by tightening a tourniquet, the pressure can soon damage nerves (>500 mm Hg) while remaining ineffective. Many tourniquet manufacturers are unaware...testing, and clinical use.2,57 TOURNIQUET USE, TISSUE ISCHEMIA, AND LIMB FUNCTION Skin , bone, tendon, fat, fascia, joints, and vessels tolerate ischemia...injury in a combat support hospital: results of a case control study. J Trauma 2008;64(Suppl 2):S99–106 [discussion: S106–7]. 21. Bellamy RF . The

  11. Investigating tendon mineralisation in the avian hindlimb: a model for tendon ageing, injury and disease

    PubMed Central

    Agabalyan, Natacha A; Evans, Darrell J R; Stanley, Rachael L

    2013-01-01

    Mineralisation of the tendon tissue has been described in various models of injury, ageing and disease. Often resulting in painful and debilitating conditions, the processes underlying this mechanism are poorly understood. To elucidate the progression from healthy tendon to mineralised tendon, an appropriate model is required. In this study, we describe the spontaneous and non-pathological ossification and calcification of tendons of the hindlimb of the domestic chicken (Gallus gallus domesticus). The appearance of the ossified avian tendon has been described previously, although there have been no studies investigating the developmental processes and underlying mechanisms leading to the ossified avian tendon. The tissue and cells from three tendons – the ossifying extensor and flexor digitorum longus tendons and the non-ossifying Achilles tendon – were analysed for markers of ageing and mineralisation using histology, immunohistochemistry, cytochemistry and molecular analysis. Histologically, the adult tissue showed a loss of healthy tendon crimp morphology as well as markers of calcium deposits and mineralisation. The tissue showed a lowered expression of collagens inherent to the tendon extracellular matrix and presented proteins expressed by bone. The cells from the ossified tendons showed a chondrogenic and osteogenic phenotype as well as tenogenic phenotype and expressed the same markers of ossification and calcification as the tissue. A molecular analysis of the gene expression of the cells confirmed these results. Tendon ossification within the ossified avian tendon seems to be the result of an endochondral process driven by its cells, although the roles of the different cell populations have yet to be elucidated. Understanding the role of the tenocyte within this tissue and the process behind tendon ossification may help us prevent or treat ossification that occurs in injured, ageing or diseased tendon. PMID:23826786

  12. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Kairui; Zhang, Sheng; Li, Qianqian

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aimsmore » to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation.« less

  13. Fos Promotes Early Stage Teno-Lineage Differentiation of Tendon Stem/Progenitor Cells in Tendon.

    PubMed

    Chen, Jialin; Zhang, Erchen; Zhang, Wei; Liu, Zeyu; Lu, Ping; Zhu, Ting; Yin, Zi; Backman, Ludvig J; Liu, Huanhuan; Chen, Xiao; Ouyang, Hongwei

    2017-11-01

    Stem cells have been widely used in tendon tissue engineering. The lack of refined and controlled differentiation strategy hampers the tendon repair and regeneration. This study aimed to find new effective differentiation factors for stepwise tenogenic differentiation. By microarray screening, the transcript factor Fos was found to be expressed in significantly higher amounts in postnatal Achilles tendon tissue derived from 1 day as compared with 7-days-old rats. It was further confirmed that expression of Fos decreased with time in postnatal rat Achilles tendon, which was accompanied with the decreased expression of multiply tendon markers. The expression of Fos also declined during regular in vitro cell culture, which corresponded to the loss of tendon phenotype. In a cell-sheet and a three-dimensional cell culture model, the expression of Fos was upregulated as compared with in regular cell culture, together with the recovery of tendon phenotype. In addition, significant higher expression of tendon markers was found in Fos-overexpressed tendon stem/progenitor cells (TSPCs), and Fos knock-down gave opposite results. In situ rat tendon repair experiments found more normal tendon-like tissue formed and higher tendon markers expression at 4 weeks postimplantation of Fos-overexpressed TSPCs derived nonscaffold engineering tendon (cell-sheet), as compared with the control group. This study identifies Fos as a new marker and functional driver in the early stage teno-lineage differentiation of tendon, which paves the way for effective stepwise tendon differentiation and future tendon regeneration. Stem Cells Translational Medicine 2017;6:2009-2019. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  14. Hamstring tendon versus patellar tendon anterior cruciate ligament reconstruction using biodegradable interference fit fixation: a prospective matched-group analysis.

    PubMed

    Wagner, Michael; Kääb, Max J; Schallock, Jessica; Haas, Norbert P; Weiler, Andreas

    2005-09-01

    There are still controversies about graft selection for primary anterior cruciate ligament reconstruction, especially with respect to knee stability and functional outcome. Biodegradable interference screw fixation of hamstring tendon grafts provides clinical results similar to those achieved with identical fixation of bone-patellar tendon-bone grafts. Cohort study; Level of evidence, 2. In 1996 and 1997, primary isolated anterior cruciate ligament reconstruction using a bone-patellar tendon-bone autograft was performed in 72 patients. Since 1998, hamstring tendons were used as routine grafts. Matched patients with a hamstring tendon graft were selected from a database (n = 284). All patients were followed prospectively for a minimum of 2 years with KT-1000 arthrometer testing, International Knee Documentation Committee score, and Lysholm score. In the bone-patellar tendon-bone group, 9 patients were excluded because of bilateral rupture of the anterior cruciate ligament, 3 patients (4.2%) had a graft rupture, and 4 patients were lost to follow-up (follow-up rate, 92.1%), leaving 56 patients for a matched-group analysis. In the hamstring tendon database, the graft rupture rate was 5.6% (P = .698). The Lysholm score was 89.7 in the patellar tendon group and 94 in the hamstring tendon group (P = .003). The KT-1000 arthrometer side-to-side difference was 2.6 mm for the patellar tendon group and 2.1 mm for the hamstring tendon group (P = .041). There were significantly less positive pivot-shift test results in the hamstring tendon group (P = .005), and hamstring tendon patients showed lower thigh atrophy (P = .024) and patellofemoral crepitus (P = .003). Overall International Knee Documentation Committee scores were better (P = .001) in the hamstring tendon group (hamstring tendon: 34 x A, 21 x B, 0 x C, 0 x D; bone-patellar tendon-bone: 17 x A, 32 x B, 6 x C, 0 x D). In this comparison of anterior cruciate ligament reconstruction with bone-patellar tendon-bone and anatomical hamstring tendon grafts, the hamstring tendon graft was superior in knee stability and function. These findings are partially contrary to previous studies and might be attributable to the use of an anatomical joint line fixation for hamstring tendon grafts. Thus, hamstring tendons are the authors' primary graft choice for anterior cruciate ligament reconstruction, even in high-level athletes.

  15. Tendon-to-bone attachment: from development to maturity.

    PubMed

    Zelzer, Elazar; Blitz, Einat; Killian, Megan L; Thomopoulos, Stavros

    2014-03-01

    The attachment between tendon and bone occurs across a complex transitional tissue that minimizes stress concentrations and allows for load transfer between muscles and skeleton. This unique tissue cannot be reconstructed following injury, leading to high incidence of recurrent failure and stressing the need for new clinical approaches. This review describes the current understanding of the development and function of the attachment site between tendon and bone. The embryonic attachment unit, namely, the tip of the tendon and the bone eminence into which it is inserted, was recently shown to develop modularly from a unique population of Sox9- and Scx-positive cells, which are distinct from tendon fibroblasts and chondrocytes. The fate and differentiation of these cells is regulated by transforming growth factor beta and bone morphogenetic protein signaling, respectively. Muscle loads are then necessary for the tissue to mature and mineralize. Mineralization of the attachment unit, which occurs postnatally at most sites, is largely controlled by an Indian hedgehog/parathyroid hormone-related protein feedback loop. A number of fundamental questions regarding the development of this remarkable attachment system require further study. These relate to the signaling mechanism that facilitates the formation of an interface with a gradient of cellular and extracellular phenotypes, as well as to the interactions between tendon and bone at the point of attachment. Copyright © 2014 Wiley Periodicals, Inc.

  16. Angiopoietin‐like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts

    PubMed Central

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G

    2016-01-01

    Key points Angiopoietin‐like 4 (ANGPTL4) modulates tendon neovascularization.Cyclic loading stimulates the activity of transforming growth factor‐β and hypoxia‐inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells.Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. Abstract The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin‐like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor‐β (TGF‐β) and hypoxia‐inducible factor 1α (HIF‐1α) signalling, and the released ANGPTL4 was pro‐angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF‐β and HIF‐1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. PMID:26670924

  17. Design and Application of a Field Sensing System for Ground Anchors in Slopes

    PubMed Central

    Choi, Se Woon; Lee, Jihoon; Kim, Jong Moon; Park, Hyo Seon

    2013-01-01

    In a ground anchor system, cables or tendons connected to a bearing plate are used for stabilization of slopes. Then, the stability of a slope is dependent on maintaining the tension levels in the cables. So far, no research on a strain-based field sensing system for ground anchors has been reported. Therefore, in this study, a practical monitoring system for long-term sensing of tension levels in tendons for anchor-reinforced slopes is proposed. The system for anchor-reinforced slopes is composed of: (1) load cells based on vibrating wire strain gauges (VWSGs), (2) wireless sensor nodes which receive and process the signals from load cells and then transmit the result to a master node through local area communication, (3) master nodes which transmit the data sent from sensor nodes to the server through mobile communication, and (4) a server located at the base station. The system was applied to field sensing of ground anchors in the 62 m-long and 26 m-high slope at the side of the highway. Based on the long-term monitoring, the safety of the anchor-reinforced slope can be secured by the timely applications of re-tensioning processes in tendons. PMID:23507820

  18. Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons.

    PubMed

    Thorpe, Chavaunne T; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2017-07-01

    Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy storing tendons. This is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms that result in this reduced fatigue resistance will aid in the development of treatments and interventions to prevent age-related tendinopathy. Copyright © 2017. Published by Elsevier Ltd.

  19. Tendon injuries

    PubMed Central

    Wu, Fan; Nerlich, Michael; Docheva, Denitsa

    2017-01-01

    Tendons connect muscles to bones, ensuring joint movement. With advanced age, tendons become more prone to degeneration followed by injuries. Tendon repair often requires lengthy periods of rehabilitation, especially in elderly patients. Existing medical and surgical treatments often fail to regain full tendon function. The development of novel treatment methods has been hampered due to limited understanding of basic tendon biology. Recently, it was discovered that tendons, similar to other mesenchymal tissues, contain tendon stem/progenitor cells (TSPCs) which possess the common stem cell properties. The current strategies for enhancing tendon repair consist mainly of applying stem cells, growth factors, natural and artificial biomaterials alone or in combination. In this review, we summarise the basic biology of tendon tissues and provide an update on the latest repair proposals for tendon tears. Cite this article: EFORT Open Rev 2017;2:332-342. DOI: 10.1302/2058-5241.2.160075 PMID:28828182

  20. It's positive to be negative: Achilles tendon work loops during human locomotion.

    PubMed

    Zelik, Karl E; Franz, Jason R

    2017-01-01

    Ultrasound imaging is increasingly used with motion and force data to quantify tendon dynamics during human movement. Frequently, tendon dynamics are estimated indirectly from muscle fascicle kinematics (by subtracting muscle from muscle-tendon unit length), but there is mounting evidence that this Indirect approach yields implausible tendon work loops. Since tendons are passive viscoelastic structures, when they undergo a loading-unloading cycle they must exhibit a negative work loop (i.e., perform net negative work). However, prior studies using this Indirect approach report large positive work loops, often estimating that tendons return 2-5 J of elastic energy for every 1 J of energy stored. More direct ultrasound estimates of tendon kinematics have emerged that quantify tendon elongations by tracking either the muscle-tendon junction or localized tendon tissue. However, it is unclear if these yield more plausible estimates of tendon dynamics. Our objective was to compute tendon work loops and hysteresis losses using these two Direct tendon kinematics estimates during human walking. We found that Direct estimates generally resulted in negative work loops, with average tendon hysteresis losses of 2-11% at 1.25 m/s and 33-49% at 0.75 m/s (N = 8), alluding to 0.51-0.98 J of tendon energy returned for every 1 J stored. We interpret this finding to suggest that Direct approaches provide more plausible estimates than the Indirect approach, and may be preferable for understanding tendon energy storage and return. However, the Direct approaches did exhibit speed-dependent trends that are not consistent with isolated, in vitro tendon hysteresis losses of about 5-10%. These trends suggest that Direct estimates also contain some level of error, albeit much smaller than Indirect estimates. Overall, this study serves to highlight the complexity and difficulty of estimating tendon dynamics non-invasively, and the care that must be taken to interpret biological function from current ultrasound-based estimates.

  1. Frequency characteristics of human muscle and cortical responses evoked by noisy Achilles tendon vibration.

    PubMed

    Mildren, Robyn L; Peters, Ryan M; Hill, Aimee J; Blouin, Jean-Sébastien; Carpenter, Mark G; Inglis, J Timothy

    2017-05-01

    Noisy stimuli, along with linear systems analysis, have proven to be effective for mapping functional neural connections. We explored the use of noisy (10-115 Hz) Achilles tendon vibration to examine somatosensory reflexes in the triceps surae muscles in standing healthy young adults ( n = 8). We also examined the association between noisy vibration and electrical activity recorded over the sensorimotor cortex using electroencephalography. We applied 2 min of vibration and recorded ongoing muscle activity of the soleus and gastrocnemii using surface electromyography (EMG). Vibration amplitude was varied to characterize reflex scaling and to examine how different stimulus levels affected postural sway. Muscle activity from the soleus and gastrocnemii was significantly correlated with the tendon vibration across a broad frequency range (~10-80 Hz), with a peak located at ~40 Hz. Vibration-EMG coherence positively scaled with stimulus amplitude in all three muscles, with soleus displaying the strongest coupling and steepest scaling. EMG responses lagged the vibration by ~38 ms, a delay that paralleled observed response latencies to tendon taps. Vibration-evoked cortical oscillations were observed at frequencies ~40-70 Hz (peak ~54 Hz) in most subjects, a finding in line with previous reports of sensory-evoked γ-band oscillations. Further examination of the method revealed 1 ) accurate reflex estimates could be obtained with <60 s of low-level (root mean square = 10 m/s 2 ) vibration; 2 ) responses did not habituate over 2 min of exposure; and importantly, 3 ) noisy vibration had a minimal influence on standing balance. Our findings suggest noisy tendon vibration is an effective novel approach to characterize somatosensory reflexes during standing. NEW & NOTEWORTHY We applied noisy (10-115 Hz) vibration to the Achilles tendon to examine the frequency characteristics of lower limb somatosensory reflexes during standing. Ongoing muscle activity was coherent with the noisy vibration (peak coherence ~40 Hz), and coherence positively scaled with increases in stimulus amplitude. Our findings suggest that noisy tendon vibration, along with linear systems analysis, is an effective novel approach to study somatosensory reflex actions in active muscles. Copyright © 2017 the American Physiological Society.

  2. [EFFECT OF RECOMBINANT ADENOVIRUS-BONE MORPHOGENETIC PROTEIN 12 TRANSFECTION ON DIFFERENTIATION OF PERIPHERAL BLOOD MESENCHYMAL STEM CELLS INTO TENDON/LIGAMENT CELLS].

    PubMed

    Fu, Weili; Chen, Gang; Tang, Xin; Li, Qi; Ll, Jian

    2015-04-01

    To research the effect of recombinant adenovirus-bone morphogenetic protein 12 (Ad-BMP-12) transfection on the differentiation of peripheral blood mesenchymal stem cells (MSCs) into tendon/ligament cells. Peripheral blood MSCs were isolated from New Zealand rabbits (3-4 months old) and cultured in vitro until passage 3. The recombinant adenoviral vector system was prepared using AdEasy system, then transfected into MSCs at passage 3 (transfected group); untransfected MSCs served as control (untransfected group). The morphological characteristics and growth of transfected cells were observed under inverted phase contrast microscope. The transfection efficiency and green fluorescent protein (GFP) expression were detected by flow cytometry (FCM) and fluorescence microscopy. After cultured for 14 days in vitro, the expressions of tendon/ligament-specific markers were determined by immunohistochemistry and real-time fluorescent quantitative PCR. GFP expression could be observed in peripheral blood MSCs at 8 hours after transfection. At 24 hours after transfection, the cells had clear morphology and grew slowly under inverted phase contrast microscope and almost all expressed GFP at the same field under fluorescence microscopy. FCM analysis showed that the transfection efficiency of the transfected group was 99.57%, while it was 2.46% in the untransfected group. The immunohistochemistry showed that the expression of collagen type I gradually increased with culture time in vitro. Real-time fluorescent quantitative PCR results showed that the mRNA expressions of the tendon/ligament-specific genes (Tenomodulin, Tenascin-C, and Decorin) in the transfected group were significantly higher than those in untransfected group (0.061+/- 0.013 vs. 0.004 +/- 0.002, t = -7.700, P=0.031; 0.029 +/- 0.008 vs. 0.003 +/- 0.001, t = -5.741, P=0.020; 0.679 +/- 0.067 vs. 0.142 +/- 0.024, t = -12.998, P=0.000). Ad-BMP-12 can significantly promote differentiation of peripheral blood MSCs into tendon/ligament fibroblasts and enhance the expressions of tendon/ligament-specific phenotypic differentiation, which would provide the evidence for peripheral blood MSCs applied for tendon/ligament regeneration.

  3. Tendon Mineralization Is Progressive and Associated with Deterioration of Tendon Biomechanical Properties, and Requires BMP-Smad Signaling in the Mouse Achilles Tendon Injury Model

    PubMed Central

    Zhang, Kairui; Asai, Shuji; Hast, Michael W.; Liu, Min; Usami, Yu; Iwamoto, Masahiro; Soslowsky, Louis J.; Enomoto-Iwamoto, Motomi

    2016-01-01

    Ectopic tendon mineralization can develop following tendon rupture or trauma surgery. The pathogenesis of ectopic tendon mineralization and its clinical impact have not been fully elucidated yet. In this study, we utilized a mouse Achilles tendon injury model to determine whether ectopic tendon mineralization alters the biomechanical properties of the tendon and whether BMP signaling is involved in this condition. A complete transverse incision was made at the midpoint of the right Achilles tendon in 8-week-old CD1 mice and the gap was left open. Ectopic cartilaginous mass formation was found in the injured tendon by 4 weeks post-surgery and ectopic mineralization was detected at 8–10 weeks post-surgery. Ectopic mineralization grew over time and volume of the mineralized materials of 25-weeks samples was about 2.5 fold bigger than that of 10-weeks samples, indicating that injury-induced ectopic tendon mineralization is progressive. In vitro mechanical testing showed that max force, max stress and mid-substance modulus in the 25-weeks samples were significantly lower than the 10-weeks samples. We observed substantial increases in expression of bone morphogenetic protein family genes in injured tendons 1 week post-surgery. Immunohistochemical analysis showed that phosphorylation of both Smad1 and Smad3 were highly increased in injured tendons as early as 1 week post-injury and remained high in ectopic chondrogenic lesions 4 weeks post-injury. Treatment with the BMP receptor kinase inhibitor (LDN193189) significantly inhibited injury-induced tendon mineralization. These findings indicate that injury-induced ectopic tendon mineralization is progressive, involves BMP signaling and associated with deterioration of tendon biomechanical properties. PMID:26825318

  4. Angiopoietin-like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts.

    PubMed

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G; Duronio, Vincent

    2016-06-01

    Angiopoietin-like 4 (ANGPTL4) modulates tendon neovascularization. Cyclic loading stimulates the activity of transforming growth factor-β and hypoxia-inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells. Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin-like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor-β (TGF-β) and hypoxia-inducible factor 1α (HIF-1α) signalling, and the released ANGPTL4 was pro-angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF-β and HIF-1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  5. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    PubMed

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria. Meanwhile, tendon allografts sterilised by this method maintain their physiological tendon structure, biomechanical integrity and good compatibility.

  6. Structure-function relationships in tendons: a review

    PubMed Central

    Benjamin, M; Kaiser, E; Milz, S

    2008-01-01

    The purpose of the current review is to highlight the structure-function relationship of tendons and related structures to provide an overview for readers whose interest in tendons needs to be underpinned by anatomy. Because of the availability of several recent reviews on tendon development and entheses, the focus of the current work is primarily directed towards what can best be described as the ‘tendon proper’ or the ‘mid-substance’ of tendons. The review covers all levels of tendon structure from the molecular to the gross and deals both with the extracellular matrix and with tendon cells. The latter are often called ‘tenocytes’ and are increasingly recognized as a defined cell population that is functionally and phenotypically distinct from other fibroblast-like cells. This is illustrated by their response to different types of mechanical stress. However, it is not only tendon cells, but tendons as a whole that exhibit distinct structure-function relationships geared to the changing mechanical stresses to which they are subject. This aspect of tendon biology is considered in some detail. Attention is briefly directed to the blood and nerve supply of tendons, for this is an important issue that relates to the intrinsic healing capacity of tendons. Structures closely related to tendons (joint capsules, tendon sheaths, pulleys, retinacula, fat pads and bursae) are also covered and the concept of a ‘supertendon’ is introduced to describe a collection of tendons in which the function of the whole complex exceeds that of its individual members. Finally, attention is drawn to the important relationship between tendons and fascia, highlighted by Wood Jones in his concept of an ‘ectoskeleton’ over half a century ago – work that is often forgotten today. PMID:18304204

  7. Conditioning of the Achilles tendon via ankle exercise improves correlations between sonographic measures of tendon thickness and body anthropometry.

    PubMed

    Wearing, Scott C; Grigg, Nicole L; Hooper, Sue L; Smeathers, James E

    2011-05-01

    Although conditioning is routinely used in mechanical tests of tendon in vitro, previous in vivo research evaluating the influence of body anthropometry on Achilles tendon thickness has not considered its potential effects on tendon structure. This study evaluated the relationship between Achilles tendon thickness and body anthropometry in healthy adults both before and after resistive ankle plantarflexion exercise. A convenience sample of 30 healthy male adults underwent sonographic examination of the Achilles tendon in addition to standard anthropometric measures of stature and body weight. A 10-5 MHz linear array transducer was used to acquire longitudinal sonograms of the Achilles tendon, 20 mm proximal to the tendon insertion. Participants then completed a series (90-100 repetitions) of conditioning exercises against an effective resistance between 100% and 150% body weight. Longitudinal sonograms were repeated immediately on completion of the exercise intervention, and anteroposterior Achilles tendon thickness was determined. Achilles tendon thickness was significantly reduced immediately following conditioning exercise (t = 9.71, P < 0.001), resulting in an average transverse strain of -18.8%. In contrast to preexercise measures, Achilles tendon thickness was significantly correlated with body weight (r = 0.72, P < 0.001) and to a lesser extent height (r = 0.45, P = 0.01) and body mass index (r = 0.63, P < 0.001) after exercise. Conditioning of the Achilles tendon via resistive ankle exercises induces alterations in tendon structure that substantially improve correlations between Achilles tendon thickness and body anthropometry. It is recommended that conditioning exercises, which standardize the load history of tendon, are employed before measurements of sonographic tendon thickness in vivo.

  8. A wrist tendon travel assessment of hand movements associated with industrial repetitive activities.

    PubMed

    Ugbolue, U Chris; Nicol, Alexander C

    2012-01-01

    To investigate slow and fast paced industrial activity hand repetitive movements associated with carpal tunnel syndrome where movements are evaluated based on finger and wrist tendon travel measurements. Nine healthy subjects were recruited for the study aged between 23 and 33 years. Participants mimicked an industrial repetitive task by performing the following activities: wrist flexion and extension task, palm open and close task; and pinch task. Each task was performed for a period of 5 minutes at a slow (0.33 Hz) and fast (1 Hz) pace for a duration of 3 minutes and 2 minutes respectively. Tendon displacement produced higher flexor digitorum superficialis (FDS) tendon travel when compared to the flexor digitorum profundus (FDP) tendons. The left hand mean (SD) tendon travel for the FDS tendon and FDP tendon were 11108 (5188) mm and 9244 (4328) mm while the right hand mean tendon travel (SD) for the FDS tendon and FDP tendon were 9225 (3441) mm and 7670 (2856) mm respectively. Of the three tasks mimicking an industrial repetitive activity, the wrist flexion and extension task produced the most tendon travel. The findings may be useful to researchers in classifying the level of strenuous activity in relation to tendon travel.

  9. Achilles tendon: US examination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fornage, B.D.

    Real-time ultrasonography (US) using linear-array probes and a stand-off pad as a ''waterpath'' was performed to evaluate the Achilles tendon in 67 patients (including 24 athletes) believed to have acute or chronic traumatic or inflammatory pathologic conditions. Tendons in 23 patients appeared normal on US scans. The 44 abnormal tendons comprised five complete and four partial ruptures, seven instances of postoperative change, and 28 cases of tendonitis. US depiction of the inner structure of the tendon resulted in the diagnosis of focal abnormalities, including partial ruptures, nodules, and calcifications. Tendonitis was characterized by enlargement and decreased echogenicity of the tendon.more » The normal US appearance of the Achilles tendon is described.« less

  10. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    PubMed

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  11. Effects of running on human Achilles tendon length-tension properties in the free and gastrocnemius components.

    PubMed

    Lichtwark, Glen A; Cresswell, Andrew G; Newsham-West, Richard J

    2013-12-01

    The elastic properties of the human Achilles tendon are important for locomotion; however, in vitro tests suggest that repeated cyclic contractions lead to tendon fatigue - an increase in length in response to stress applied. In vivo experiments have not, however, demonstrated mechanical fatigue in the Achilles tendon, possibly due to the limitations of using two-dimensional ultrasound imaging to assess tendon strain. This study used freehand three-dimensional ultrasound (3DUS) to determine whether the free Achilles tendon (calcaneus to soleus) or the gastrocnemius tendon (calcaneus to gastrocnemius) demonstrated tendon fatigue after running exercise. Participants (N=9) underwent 3DUS scans of the Achilles tendon during isometric contractions at four ankle torque levels (passive, and 14, 42 and 70 N m) before and after a 5 km run at a self-selected pace (10-14 km h(-1)). Running had a significant main effect on the length of the free Achilles tendon (P<0.01) with a small increase in length across the torque range. However, the mean lengthening effect was small (<1%) and was not accompanied by a change in free tendon stiffness. There was no significant change in the length of the gastrocnemius tendon or the free tendon cross-sectional area. While the free tendon was shown to lengthen, the lack of change in stiffness suggests the tendon exhibited mechanical creep rather than fatigue. These effects were much smaller than those predicted from in vitro experiments, possibly due to the different loading profile encountered and the ability of the tendon to repair in vivo.

  12. Markers for the identification of tendon-derived stem cells in vitro and tendon stem cells in situ - update and future development.

    PubMed

    Lui, Pauline Po Yee

    2015-06-02

    The efficacy of tendon-derived stem cells (TDSCs) for the promotion of tendon and tendon-bone junction repair has been reported in animal studies. Modulation of the tendon stem cell niche in vivo has also been reported to influence tendon structure. There is a need to have specific and reliable markers that can define TDSCs in vitro and tendon stem cells in situ for several reasons: to understand the basic biology of TDSCs and their subpopulations in vitro; to understand the identity, niches and functions of tendon/progenitor stem cells in vivo; to meet the governmental regulatory requirements for quality of TDSCs when translating the exciting preclinical findings into clinical trial/practice; and to develop new treatment strategies for mobilizing endogenous stem/progenitor cells in tendon. TDSCs were reported to express the common mesenchymal stem cell (MSC) markers and some embryonic stem cell (ESC) markers, and there were attempts to use these markers to label tendon stem cells in situ. Are these stem cell markers useful for the identification of TDSCs in vitro and tracking of tendon stem cells in situ? This review aims to discuss the values of the panel of MSC, ESC and tendon-related markers for the identification of TDSCs in vitro. Important factors influencing marker expression by TDSCs are discussed. The usefulness and limitations of the panel of MSC, ESC and tendon-related markers for tracking stem cells in tendon, especially tendon stem cells, in situ are then reviewed. Future research directions are proposed.

  13. Tendon-Holding Capacities of Two Newly Designed Implants for Tendon Repair: An Experimental Study on the Flexor Digitorum Profundus Tendon of Sheep

    PubMed Central

    Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent

    2014-01-01

    Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965

  14. Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy

    PubMed Central

    Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.

    2013-01-01

    Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745

  15. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    PubMed

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  16. Quantitative ultrasound method for assessing stress-strain properties and the cross-sectional area of Achilles tendon

    NASA Astrophysics Data System (ADS)

    Du, Yi-Chun; Chen, Yung-Fu; Li, Chien-Ming; Lin, Chia-Hung; Yang, Chia-En; Wu, Jian-Xing; Chen, Tainsong

    2013-12-01

    The Achilles tendon is one of the most commonly observed tendons injured with a variety of causes, such as trauma, overuse and degeneration, in the human body. Rupture and tendinosis are relatively common for this strong tendon. Stress-strain properties and shape change are important biomechanical properties of the tendon to assess surgical repair or healing progress. Currently, there are rather limited non-invasive methods available for precisely quantifying the in vivo biomechanical properties of the tendons. The aim of this study was to apply quantitative ultrasound (QUS) methods, including ultrasonic attenuation and speed of sound (SOS), to investigate porcine tendons in different stress-strain conditions. In order to find a reliable method to evaluate the change of tendon shape, ultrasound measurement was also utilized for measuring tendon thickness and compared with the change in tendon cross-sectional area under different stress. A total of 15 porcine tendons of hind trotters were examined. The test results show that the attenuation and broadband ultrasound attenuation decreased and the SOS increased by a smaller magnitude as the uniaxial loading of the stress-strain upon tendons increased. Furthermore, the tendon thickness measured with the ultrasound method was significantly correlated with tendon cross-sectional area (Pearson coefficient = 0.86). These results also indicate that attenuation of QUS and ultrasonic thickness measurement are reliable and potential parameters for assessing biomechanical properties of tendons. Further investigations are needed to warrant the application of the proposed method in a clinical setting.

  17. In vitro kinematic measurements of the patellar tendon in two different types of posterior-stabilized total knee arthroplasties.

    PubMed

    Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi

    2010-01-01

    Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.

  18. Treatment of mallet finger deformity with a modified palmaris longus tendon graft through a bone tunnel.

    PubMed

    Liu, Zengbing; Ma, Kai; Huang, Dong

    2018-01-01

    To investigate the clinical effect of treating mallet finger deformity using a modified palmaris longus tendon graft through a bone tunnel. Altogether, 21 patients with mallet finger deformity (16 men, 5 women; average age 31 years, range 19-47 years) were treated with a modified palmaris longus tendon graft through a bone tunnel during 18 months (2014-2016). Four index fingers, seven middle fingers, eight ring fingers, and two little fingers were treated for four cutting injuries, eleven finger sprains, four crush injuries, and two twist injuries (7 open and 14 closed injuries). Duration from injury to surgery was 9 h to 13 weeks. Three patients underwent surgery after 6 weeks of unsuccessful conservative treatment. No tendon was attached to the extensor tendon insertion in 16 patients, and 5 had residual tendon of <0.2 cm attached. All patients had distal segment flexion deformity and dorsiflexion disorder. Surgery comprised transverse penetration and vertical drilling of the base of the distal phalanx (2.0 and 2.5 mm diameter drills). Equal shallow semitendinosus pieces of the palmaris longus tendon (4 cm) were obtained from the sagittal end and were passed through a dorsal bone hole, emerging from a transverse bone hole. The two bundles were sutured to the main tendon. Tension was adjusted, and the broken ends were sutured. The distal interphalangeal joints were fixed in hyperextension. All patients were followed for 7-16 months (average 6.0 ± 0.3 months) postoperatively. All 21 patients had grade A wound healing, with no complications (e.g., necrotic wound, recurrence, joint stiffness). The mallet finger deformity was corrected with good appearance, no obvious abnormalities, and satisfactory flexion and extension. Two patients had a superficial wound infection. Each recovered after symptomatic treatment. One patient had a mild result, with limited extension. There were no recurrences. Results were evaluated according to Patel et al.'s system, which revealed 15 excellent and 5 good results (combined 95.23% rate), with 1 mild result (limited extension). Patients were satisfied with the appearance and function of the affected fingers, and the desired surgical end result was achieved. Use of this modified surgery for treating mallet finger deformity, especially with no or little tendon attached at the extensor tendon insertion, results in nearly anatomical reconstruction of the extensor tendon insertion. Its advantages include simple surgery, reliable fixation, fewer complications, and clinical efficacy.

  19. Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction: A Canine in Vivo Model.

    PubMed

    Wei, Zhuang; Reisdorf, Ramona L; Thoreson, Andrew R; Jay, Gregory D; Moran, Steven L; An, Kai-Nan; Amadio, Peter C; Zhao, Chunfeng

    2018-04-04

    Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.

  20. Effect of a prehop on the muscle-tendon interaction during vertical jumps.

    PubMed

    Aeles, Jeroen; Lichtwark, Glen; Peeters, Dries; Delecluse, Christophe; Jonkers, Ilse; Vanwanseele, Benedicte

    2018-05-01

    Many movements use stretch-shortening cycles of a muscle-tendon unit (MTU) for storing and releasing elastic energy. The required stretching of medial gastrocnemius (MG) tendinous tissue during jumps, however, requires large length changes of the muscle fascicles because of the lack of MTU length changes. This has a negative impact on the force-generating capacity of the muscle fascicles. The purpose of this study was to induce a MG MTU stretch before shortening by adding a prehop to the squat jump. Eleven well-trained athletes specialized in jumping performed a prehop squat jump (PHSJ) and a standard squat jump (SSJ). Kinematic data were collected using a 3D motion capture system and were used in a musculoskeletal model to calculate MTU lengths. B-mode ultrasonography of the MG was used to measure fascicle length and pennation angle during the jumps. By combining the muscle-tendon unit lengths, fascicle lengths, and pennation angles, the stretch and recoil of the series elastic element of MG were calculated using a simple geometric muscle-tendon model. Our results show less length changes of the muscle fascicles during the upward motion and lower maximal shortening velocities, increasing the moment-generating capacity of the plantar flexors, reflected in the higher ankle joint moment in the PHSJ compared with the SSJ. Although muscle-tendon interaction during the PHSJ was more optimal, athletes were not able to increase their jump height compared with the SSJ. NEW & NOTEWORTHY This is the first study that aimed to improve the muscle-tendon interaction in squat jumping. We effectively introduced a stretch to the medial gastrocnemius muscle-tendon unit resulting in lower maximal shortening velocities and thus an increase in the plantar flexor force-generating capacity, reflected in the higher ankle joint moment in the prehop squat jump compared with the standard squat jump. Here, we demonstrate an effective method for mechanical optimization of the muscle-tendon interaction in the medial gastrocnemius during squat jumping.

  1. RoboGlove: Initial Work Toward a Robotically Assisted EVA Glove

    NASA Technical Reports Server (NTRS)

    Rogers, Jonathan

    2015-01-01

    The RoboGlove is a device designed to provide additional grip strength or endurance for a user. In applying this Robonaut 2 spinoff technology to the Phase VI Space Suit glove, the project is using robotic tendons and actuators to regain some of the hand performance that is lost when wearing a pressurized glove. An array of sensors embedded into the finger softgoods provides input to the control system which retracts the tendons, helping to close the user's hand. While active, this system provides augmentation, but is nonintrusive to glove usage when disabled.

  2. Patellar tendon re-rupture on the opposite end of the previous site of surgical repair

    PubMed Central

    KOH, Bryan Thean Howe; SAYAMPANATHAN, Andrew A; LEE, Keng Thiam

    2017-01-01

    We describe a rare case of a patellar tendon “re-rupture” at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial tuberosity. The patellar tendon was repaired using two 5.5 mm BioCorkscrews (Arthrex) inserted into the tibial tuberosity; the tendon was stitched with the No. 2 fiberwires using Krackow technique. As the patellar tendon was degenerative, the repair was augmented with a semitendinosus tendon harvested using an open tendon stripper, leaving the distal attachment intact. At 2.6 years followup he had mild anterior knee pain, range of motion 0-130° and was able to squat. MRI scan done at followup revealed good healing of repaired patellar tendon. PMID:28566788

  3. Influence of the position of the foot on MRI signal in the deep digital flexor tendon and collateral ligaments of the distal interphalangeal joint in the standing horse.

    PubMed

    Spriet, M; Zwingenberger, A

    2009-05-01

    Hyperintense signal is sometimes observed in ligaments and tendons of the equine foot on standing magnetic resonance examination without associated changes in size and shape. In such cases, the presence of a true lesion or an artifact should be considered. A change in position of a ligament or tendon relative to the magnetic field can induce increased signal intensity due to the magic angle effect. To assess if positional rotation of the foot in the solar plane could be responsible for artifactual changes in signal intensity in the collateral ligaments of the distal interphalangeal joint and in the deep digital flexor tendon. Six isolated equine feet were imaged with a standing equine magnetic resonance system in 9 different positions with different degrees of rotation in the solar plane. Rotation of the limb induced a linear hyperintense signal on all feet at the palmar aspect of one of the lobes of the deep digital flexor tendon and at the dorsal aspect of the other lobe. Changes in signal intensity in the collateral ligaments of the distal interphalangeal joint occurred with rotation of the limb only in those feet where mediolateral hoof imbalance was present. The position and conformation of the foot influence the signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint. The significance of increased signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint should be interpreted with regard to the position and the conformation of the foot.

  4. Photodiode Camera Measurement of Surface Strains on Tendons during Multiple Cyclic Tests

    NASA Astrophysics Data System (ADS)

    Chun, Keyoung Jin; Hubbard, Robert Philip

    The objectives of this study are to introduce the use of a photodiode camera for measuring surface strain on soft tissue and to present some representative responses of the tendon. Tendon specimens were obtained from the hindlimbs of canines and frozen to -70°C. After thawing, specimens were mounted in the immersion bath at a room temperature (22°C), preloaded to 0.13N and then subjected to 3% of the initial length at a strain rate of 2%/sec. In tendons which were tested in two blocks of seven repeated extensions to 3% strain with a 120 seconds wait period between, the surface strains were measured with a photodiode camera and near the gripped ends generally were greater than the surface strains in the middle segment of the tendon specimens. The recovery for peak load after the rest period was consistent but the changes in patterns of surface strains after the rest period were not consistent. The advantages of a photodiode measurement of surface strains include the followings: 1) it is a noncontacting method which eliminates errors and distortions caused by clip gauges or mechanical/electronic transducers; 2) it is more accurate than previous noncontact methods, e.g. the VDA and the high speed photographic method; 3) it is a fully automatic, thus reducing labor for replaying video tapes or films and potential errors from human judgement which can occur during digitizing data from photographs. Because the photodiode camera, employs a solid state photodiode array to sense black and white images, scan targets (black image) on the surface of the tendon specimen and back lighting system (white image), and stored automatically image data for surface strains of the tendon specimen on the computer during cyclic extensions.

  5. A Biomechanical Comparison of Allograft Tendons for Ligament Reconstruction.

    PubMed

    Palmer, Jeremiah E; Russell, Joseph P; Grieshober, Jason; Iacangelo, Abigail; Ellison, Benjamin A; Lease, T Dylan; Kim, Hyunchul; Henn, R Frank; Hsieh, Adam H

    2017-03-01

    Allograft tendons are frequently used for ligament reconstruction about the knee, but they entail availability and cost challenges. The identification of other tissues that demonstrate equivalent performance to preferred tendons would improve limitations. Hypothesis/Purpose: We compared the biomechanical properties of 4 soft tissue allograft tendons: tibialis anterior (TA), tibialis posterior (TP), peroneus longus (PL), and semitendinosus (ST). We hypothesized that allograft properties would be similar when standardized by the looped diameter. Controlled laboratory study. This study consisted of 2 arms evaluating large and small looped-diameter grafts: experiment A consisted of TA, TP, and PL tendons (n = 47 each) with larger looped diameters of 9.0 to 9.5 mm, and experiment B consisted of TA, TP, PL, and ST tendons (n = 53 each) with smaller looped diameters of 7.0 to 7.5 mm. Each specimen underwent mechanical testing to measure the modulus of elasticity (E), ultimate tensile force (UTF), maximal elongation at failure, ultimate tensile stress (UTS), and ultimate tensile strain (UTε). Experiment A: No significant differences were noted among tendons for UTF, maximal elongation at failure, and UTϵ. UTS was significantly higher for the PL (54 MPa) compared with the TA (44 MPa) and TP (43 MPa) tendons. E was significantly higher for the PL (501 MPa) compared with the TP (416 MPa) tendons. Equivalence testing showed that the TP and PL tendon properties were equivalent or superior to those of the TA tendons for all outcomes. Experiment B: All groups exhibited a similar E. UTF was again highest in the PL tendons (2294 N) but was significantly different from only the ST tendons (1915 N). UTϵ was significantly higher for the ST (0.22) compared with the TA (0.19) and TP (0.19) tendons. Equivalence testing showed that the TA, TP, and PL tendon properties were equivalent or superior to those of the ST tendons. Compared with TA tendons, TP and PL tendons of a given looped diameter exhibited noninferior initial biomechanical strength and stiffness characteristics. ST tendons were mostly similar to TA tendons but exhibited a significantly higher elongation/UTϵ and smaller cross-sectional area. For smaller looped-diameter grafts, all tissues were noninferior to ST tendons. In contrast to previous findings, PL tendons proved to be equally strong. The results of this study should encourage surgeons to use these soft tissue allografts interchangeably, which is important as the number of ligament reconstructions performed with allografts continues to rise.

  6. Histological study of the influence of plasma rich in growth factors (PRGF) on the healing of divided Achilles tendons in sheep.

    PubMed

    Fernández-Sarmiento, J Andrés; Domínguez, Juan M; Granados, María M; Morgaz, Juan; Navarrete, Rocío; Carrillo, José M; Gómez-Villamandos, Rafael J; Muñoz-Rascón, Pilar; Martín de Las Mulas, Juana; Millán, Yolanda; García-Balletbó, Montserrat; Cugat, Ramón

    2013-02-06

    The use of plasma rich in growth factors (PRGF) has been proposed to improve the healing of Achilles tendon injuries, but there is debate about the effectiveness of this therapy. The objective of the present study was to evaluate the histological effects of PRGF, which is a type of leukocyte-poor platelet-rich plasma, on tendon healing. The Achilles tendons of twenty-eight sheep were divided surgically. The animals were randomly divided into four groups of seven animals each. The repaired tendons in two groups received an infiltration of PRGF intraoperatively and every week for the following three weeks under ultrasound guidance. The tendons in the other two groups received injections with saline solution. The animals in one PRGF group and one saline solution group were killed at four weeks, and the animals in the remaining two groups were killed at eight weeks. The Achilles tendons were examined histologically, and the morphometry of fibroblast nuclei was calculated. The fibroblast nuclei of the PRGF-treated tendons were more elongated and more parallel to the tendon axis than the fibroblast nuclei of the tendons in the saline solution group at eight weeks. PRGF-treated tendons showed more packed and better oriented collagen bundles at both four and eight weeks. In addition to increased maturation of the collagen structure, fibroblast density was significantly lower in PRGF-infiltrated tendons. PRGF-treated tendons exhibited faster vascular regression than tendons in the control groups, as demonstrated by a lower vascular density at eight weeks. PRGF was associated with histological changes consistent with an accelerated early healing process in repaired Achilles tendons in sheep after experimental surgical disruption. PRGF-treated tendons showed improvements in the morphometric features of fibroblast nuclei, suggesting a more advanced stage of healing. At eight weeks, histological examination revealed more mature organization of collagen bundles, lower vascular densities, and decreased fibroblast densities in PRGF-treated tendons than in tendons infiltrated with saline solution. These findings were consistent with a more advanced stage of the healing process. Based on the findings in this animal model, PRGF infiltration may improve the early healing process of surgically repaired Achilles tendons.

  7. Rescue plan for Achilles: Therapeutics steering the fate and functions of stem cells in tendon wound healing.

    PubMed

    Schneider, Magdalena; Angele, Peter; Järvinen, Tero A H; Docheva, Denitsa

    2017-12-24

    Due to the increasing age of our society and a rise in engagement of young people in extreme and/or competitive sports, both tendinopathies and tendon ruptures present a clinical and financial challenge. Tendon has limited natural healing capacity and often responds poorly to treatments, hence it requires prolonged rehabilitation in most cases. Till today, none of the therapeutic options has provided successful long-term solutions, meaning that repaired tendons do not recover their complete strength and functionality. Our understanding of tendon biology and healing increases only slowly and the development of new treatment options is insufficient. In this review, following discussion on tendon structure, healing and the clinical relevance of tendon injury, we aim to elucidate the role of stem cells in tendon healing and discuss new possibilities to enhance stem cell treatment of injured tendon. To date, studies mainly apply stem cells, often in combination with scaffolds or growth factors, to surgically created tendon defects. Deeper understanding of how stem cells and vasculature in the healing tendon react to growth factors, common drugs used to treat injured tendons and promising cellular boosters could help to develop new and more efficient ways to manage tendon injuries. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  8. Effects of high loading by eccentric triceps surae training on Achilles tendon properties in humans.

    PubMed

    Geremia, Jeam Marcel; Baroni, Bruno Manfredini; Bobbert, Maarten Frank; Bini, Rodrigo Rico; Lanferdini, Fabio Juner; Vaz, Marco Aurélio

    2018-06-01

    To document the magnitude and time course of human Achilles tendon adaptations (i.e. changes in tendon morphological and mechanical properties) during a 12-week high-load plantar flexion training program. Ultrasound was used to determine Achilles tendon cross-sectional area (CSA), length and elongation as a function of plantar flexion torque during voluntary plantar flexion. Tendon force-elongation and stress-strain relationships were determined before the start of training (pre-training) and after 4 (post-4), 8 (post-8) and 12 (post-12) training weeks. At the end of the training program, maximum isometric force had increased by 49% and tendon CSA by 17%, but tendon length, maximal tendon elongation and maximal strain were unchanged. Hence, tendon stiffness had increased by 82%, and so had Young's modulus, by 86%. Significant changes were first detected at post-4 in stiffness (51% increase) and Young's modulus (87% increase), and at post-8 in CSA (15% increase). Achilles tendon material properties already improved after 4 weeks of high-load training: stiffness increased while CSA remained unchanged. Tendon hypertrophy (increased CSA) was observed after 8 training weeks and contributed to a further increase in Achilles tendon stiffness, but tendon stiffness increases were mostly caused by adaptations in tissue properties.

  9. Grasp Assist Device with Shared Tendon Actuator Assembly

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  10. The Effects of Bio-Lubricating Molecules on Flexor Tendon Reconstruction in A Canine Allograft Model In Vivo

    PubMed Central

    Zhao, Chunfeng; Wei, Zhuang; Kirk, Ramona L.; Thoreson, Andrew R.; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2014-01-01

    Background Using allograft is an attractive alternative for flexor tendon reconstruction because of the lack of donor morbidity, and better matching to the intrasynovial environment. The purpose of this study was to use biolubricant molecules to modify the graft surface to decrease adhesions and improve digit function. Methods 28 flexor digitorum profundus (FDP) tendons from the 2nd and 5th digits of 14 dogs were first lacerated and repaired to create a model with repair failure and scar digit for tendon reconstruction. Six weeks after the initial surgery, the tendons were reconstructed with FDP allograft tendons obtained from canine cadavers. One graft tendon in each dog was treated with saline as a control and the other was treated with gelatin, carbodiimide derivatized, hyaluronic acid and lubricin (cd-HA-Lubricin). Six weeks postoperatively, digit function, graft mechanics, and biology were analyzed. Results Allograft tendons treated with cd-HA-Lubricin had decreased adhesions at the proximal tendon/graft repair and within flexor sheath, improved digit function, and increased graft gliding ability. The treatment also reduced the strength at the distal tendon to bone repair, but the distal attachment rupture rate was similar for both graft types. Histology showed that viable cells migrated to the allograft, but these were limited to the tendon surface. Conclusion cd-HA-Lubricin treatment of tendon allograft improves digit functional outcomes after flexor tendon reconstruction. However, delayed bone-tendon healing should be a caution. Furthermore, the cell infiltration into the allograft tendons substance should be a target for future studies, to shorten the allograft self-regeneration period. PMID:24445876

  11. Biomechanical and histological effects of augmented soft tissue mobilization therapy on achilles tendinopathy in a rabbit model.

    PubMed

    Imai, Kan; Ikoma, Kazuya; Chen, Qingshan; Zhao, Chunfeng; An, Kai-Nan; Gay, Ralph E

    2015-02-01

    Augmented soft tissue mobilization (ASTM) has been used to treat Achilles tendinopathy and is thought to promote collagen fiber realignment and hasten tendon regeneration. The objective of this study was to evaluate the biomechanical and histological effects of ASTM therapy on rabbit Achilles tendons after enzymatically induced injury. This study was a non-human bench controlled research study using a rabbit model. Both Achilles tendons of 12 rabbits were injected with collagenase to produce tendon injury simulating Achilles tendinopathy. One side was then randomly allocated to receive ASTM, while the other received no treatment (control). ASTM was performed on the Achilles tendon on postoperative days 21, 24, 28, 31, 35, and 38. Tendons were harvested 10 days after treatment and examined with dynamic viscoelasticity and light microscopy. Cross-sectional area in the treated tendons was significantly greater than in controls. Storage modulus tended to be lower in the treated tendons but elasticity was not significantly increased. Loss modulus was significantly lower in the treated tendons. There was no significant difference found in tangent delta (loss modulus/storage modulus). Microscopy of control tendons showed that the tendon fibers were wavy and type III collagen was well stained. The tendon fibers of the augmented soft tissue mobilization treated tendons were not wavy and type III collagen was not prevalent. Biomechanical and histological findings showed that the Achilles tendons treated with ASTM had better recovery of biomechanical function than did control tendons. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  12. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    PubMed

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon-deficient, complete distal biceps rupture model, acellular dermal allograft augmentation restored the native tendon's biomechanical properties at time zero. The grafted tissue-deficient model demonstrated no significant differences in the load to failure and gap formation compared with the native tendon. As expected, dermal augmentation of attritional tendon repair increased the load to failure and stiffness as well as decreased displacement compared with the ungrafted tissue-deficient model. Tendons with their native width showed no statistical difference or negative biomechanical consequences of dermal augmentation. Dermal augmentation of the distal biceps is a biomechanically feasible option for patients with an attritionally thinned-out tendon.

  13. US appearance of partial-thickness supraspinatus tendon tears: Application of the string theory. Pictorial essay.

    PubMed

    Guerini, H; Fermand, M; Godefroy, D; Feydy, A; Chevrot, A; Morvan, G; Gault, N; Drapé, J L

    2012-02-01

    The supraspinatus tendon is composed of 5 different layers consisting of intertwining bundles. On a front portion of the tendon, the layers become coated bundles which insert on the trochanter. At the insertion, the superficial or bursal surface of the tendon corresponding to the tendon fibers in contact with the subacromial bursa can be distinguished from the deep surface corresponding to the fibers in contact with the glenohumeral joint. A tendon tear may involve partial or total disruption of the tendon fibers and is called full-thickness tear if it affects the entire tendon, and partial-thickness tear if it involves only part of the tendon. Partial-thickness tears of the supraspinatus tendon include lesions of the superficial, deep and central surface or tendon delamination.A contrast enhanced examination requires injection of contrast agent into the joint (arthrography followed by computed tomography (CT) or magnetic resonance imaging (MRI)) to study the deep surface, and injection into the subacromial bursa (bursography followed by CT) to study the superficial surface. MRI and ultrasound (US) examination allow the study of these different tendon layers without the use of contrast agent (which is not possible at CT).

  14. The series-elastic shock absorber: tendons attenuate muscle power during eccentric actions.

    PubMed

    Roberts, Thomas J; Azizi, Emanuel

    2010-08-01

    Elastic tendons can act as muscle power amplifiers or energy-conserving springs during locomotion. We used an in situ muscle-tendon preparation to examine the mechanical function of tendons during lengthening contractions, when muscles absorb energy. Force, length, and power were measured in the lateral gastrocnemius muscle of wild turkeys. Sonomicrometry was used to measure muscle fascicle length independently from muscle-tendon unit (MTU) length, as measured by a muscle lever system (servomotor). A series of ramp stretches of varying velocities was applied to the MTU in fully activated muscles. Fascicle length changes were decoupled from length changes imposed on the MTU by the servomotor. Under most conditions, muscle fascicles shortened on average, while the MTU lengthened. Energy input to the MTU during the fastest lengthenings was -54.4 J/kg, while estimated work input to the muscle fascicles during this period was only -11.24 J/kg. This discrepancy indicates that energy was first absorbed by elastic elements, then released to do work on muscle fascicles after the lengthening phase of the contraction. The temporary storage of energy by elastic elements also resulted in a significant attenuation of power input to the muscle fascicles. At the fastest lengthening rates, peak instantaneous power input to the MTU reached -2,143.9 W/kg, while peak power input to the fascicles was only -557.6 W/kg. These results demonstrate that tendons may act as mechanical buffers by limiting peak muscle forces, lengthening rates, and power inputs during energy-absorbing contractions.

  15. A comparison of MRI and clinical examination of acute lateral ankle sprains.

    PubMed

    Frey, C; Bell, J; Teresi, L; Kerr, R; Feder, K

    1996-09-01

    Because of its excellent soft tissue contrast and ability to demonstrate soft tissue structures, magnetic resonance imaging is ideally suited to the evaluation of the soft tissues surrounding the ankle, including the lateral collateral ligaments. This study was undertaken to compare the clinical evaluation of 15 patients who suffered inversion injuries of the ankle with the results found on magnetic resonance imaging within 48 hours of the injury. Physical examination was found to be 100% accurate in the diagnosis of grade III ligament injuries but only 25% accurate in the diagnosis of grade II injuries. Clinicians most often underestimate the damage with a grade II ligament tear. Furthermore, other associated injuries, such as significant capsule ruptures and tendon damage, were often overlooked at physical examination.

  16. Lubricin Surface Modification Improves Tendon Gliding After Tendon Repair in a Canine Model in Vitro

    PubMed Central

    Taguchi, Manabu; Sun, Yu-Long; Zhao, Chunfeng; Zobitz, Mark E.; Cha, Chung-Ja; Jay, Gregory D.; An, Kai-Nan; Amadio, Peter C.

    2011-01-01

    This study investigated the effects of lubricin on the gliding of repaired flexor digitorum profundus (FDP) tendons in vitro. Canine FDP tendons were completely lacerated, repaired with a modified Pennington technique, and treated with one of the following solutions: saline, carbodiimide derivatized gelatin/hyaluronic acid (cd-HA-gelatin), carbodiimide derivatized gelatin to which lubricin was added in a second step (cd-gelatin + lubricin), or carbodiimide derivatized gelatin/HA + lubricin (cd-HA-gelatin + lubricin). After treatment, gliding resistance was measured up to 1,000 cycles of simulated flexion/extension motion. The increase in average and peak gliding resistance in cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin tendons was less than the control tendons after 1,000 cycles (p < 0.05). The increase in average gliding resistance of cd-HA-gelatin + lubricin treated tendons was also less than that of the cd-HA-gelatin treated tendons (p < 0.05). The surfaces of the repaired tendons and associated pulleys were assessed qualitatively with scanning electron microscopy and appeared smooth after 1,000 cycles of tendon motion for the cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin treated tendons, while that of the saline control appeared roughened. These results suggest that tendon surface modification can improve tendon gliding ability, with a trend suggesting that lubricin fixed on the repaired tendon may provide additional improvement over that provided by HA and gelatin alone. PMID:18683890

  17. Fixation Strength of Polyetheretherketone Sheath-and-Bullet Device for Soft Tissue Repair in the Foot and Ankle.

    PubMed

    Christensen, Jay; Fischer, Brian; Nute, Michael; Rizza, Robert

    Tendon transfers are often performed in the foot and ankle. Recently, interference screws have been a popular choice owing to their ease of use and fixation strength. Considering the benefits, one disadvantage of such devices is laceration of the soft tissues by the implant threads during placement that potentially weaken the structural integrity of the grafts. A shape memory polyetheretherketone bullet-in-sheath tenodesis device uses circumferential compression, eliminating potential damage from thread rotation and maintaining the soft tissue orientation of the graft. The aim of this study was to determine the pullout strength and failure mode for this device in both a synthetic bone analogue and porcine bone models. Thirteen mature bovine extensor tendons were secured into ten 4.0 × 4.0 × 4.0-cm cubes of 15-pound per cubic foot solid rigid polyurethane foam bone analogue models or 3 porcine femoral condyles using the 5 × 20-mm polyetheretherketone soft tissue anchor. The bullet-in-sheath device demonstrated a mean pullout of 280.84 N in the bone analog models and 419.47 N in the porcine bone models. (p = .001). The bullet-in-sheath design preserved the integrity of the tendon graft, and none of the implants dislodged from their original position. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Pleiotropic roles of the matricellular protein Sparc in tendon maturation and ageing

    PubMed Central

    Gehwolf, Renate; Wagner, Andrea; Lehner, Christine; Bradshaw, Amy D.; Scharler, Cornelia; Niestrawska, Justyna A.; Holzapfel, Gerhard A.; Bauer, Hans-Christian; Tempfer, Herbert; Traweger, Andreas

    2016-01-01

    Acute and chronic tendinopathies remain clinically challenging and tendons are predisposed to degeneration or injury with age. Despite the high prevalence of tendon disease in the elderly, our current understanding of the mechanisms underlying the age-dependent deterioration of tendon function remains very limited. Here, we show that Secreted protein acidic and rich in cysteine (Sparc) expression significantly decreases in healthy-aged mouse Achilles tendons. Loss of Sparc results in tendon collagen fibrillogenesis defects and Sparc−/− tendons are less able to withstand force in comparison with their respective wild type counterparts. On the cellular level, Sparc-null and healthy-aged tendon-derived cells exhibited a more contracted phenotype and an altered actin cytoskeleton. Additionally, an elevated expression of the adipogenic marker genes PPARγ and Cebpα with a concomitant increase in lipid deposits in aged and Sparc−/− tendons was observed. In summary, we propose that Sparc levels in tendons are critical for proper collagen fibril maturation and its age-related decrease, together with a change in ECM properties favors lipid accretion in tendons. PMID:27586416

  19. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    PubMed

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Magnetic resonance imaging-controlled results of the pectoralis major tendon transfer for irreparable anterosuperior rotator cuff tears performed with standard and modified fixation techniques.

    PubMed

    Lederer, Stefan; Auffarth, Alexander; Bogner, Robert; Tauber, Mark; Mayer, Michael; Karpik, Stefanie; Matis, Nicholas; Resch, Herbert

    2011-10-01

    Irreparable ruptures of the subscapularis tendon lead to impaired function of the shoulder joint. In such cases, transfer of the pectoralis major tendon has led to encouraging results. The procedure fails periodically, typically associated with insufficient in-growth of the transferred tissue. We hypothesized that tendon harvest with chips of cancellous bone would improve the tendon-bone interface. Of 62 consecutive pectoralis tendon transfers, 54 shoulders were followed-up at an average of 35 months. In all shoulders, the transferred tendon was rerouted behind the conjoint tendon and fixed by transosseous sutures. In 29 shoulders, the tendon was harvested with a cuff of cancellous bone. In 25 shoulders, the conventional technique with sharp detachment of the tendon was used. Apart from detailed clinical examination of all shoulders, a magnetic resonance image (MRI) was available in 52 shoulders. The overall Constant score had improved from an average of 38.8 points preoperatively to 63.4 points at follow-up. Shoulders treated with the new fixation technique scored 64.4 compared with 62.2 for the conventional fixations. The MRI showed intact tendons and muscles in 80.8% of shoulders. In 7 shoulders (13.5%), the transferred tendon was ruptured. Two of these were treated with the new fixation technique. Mean patient satisfaction score was 8.2 points. A secure method of fixation that avoids secondary ruptures despite insufficiency of the transferred tendon is of great importance. Also the rerouting of the transferred tendon under the conjoined tendon is essential to imitate the natural force vector and the function of an intact subscapularis tendon. Patients in this investigation were also monitored by MRI to verify the integrity of the transferred tendon. As a salvage procedure, the pectoralis major tendon transfer provides good results in most cases. Sufficient in-growth of the transferred tissue is essential for the success of the procedure. This seems to be facilitated by both methods. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  1. Non-linear finite element model to assess the effect of tendon forces on the foot-ankle complex.

    PubMed

    Morales-Orcajo, Enrique; Souza, Thales R; Bayod, Javier; Barbosa de Las Casas, Estevam

    2017-11-01

    A three-dimensional foot finite element model with actual geometry and non-linear behavior of tendons is presented. The model is intended for analysis of the lower limb tendon forces effect in the inner foot structure. The geometry of the model was obtained from computational tomographies and magnetic resonance images. Tendon tissue was characterized with the first order Ogden material model based on experimental data from human foot tendons. Kinetic data was employed to set the load conditions. After model validation, a force sensitivity study of the five major foot extrinsic tendons was conducted to evaluate the function of each tendon. A synergic work of the inversion-eversion tendons was predicted. Pulling from a peroneus or tibialis tendon stressed the antagonist tendons while reducing the stress in the agonist. Similar paired action was predicted for the Achilles tendon with the tibialis anterior. This behavior explains the complex control motion performed by the foot. Furthermore, the stress state at the plantar fascia, the talocrural joint cartilage, the plantar soft tissue and the tendons were estimated in the early and late midstance phase of walking. These estimations will help in the understanding of the functional role of the extrinsic muscle-tendon-units in foot pronation-supination. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    PubMed

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P < 0.05). Pairwise comparisons revealed a significant increase in free tendon length and strain at all contraction intensities after eccentric exercise (P < 0.05). There was no significant time-by-session interaction for the gastrocnemii (medial or lateral) aponeurosis or tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Deficits in heel-rise height and achilles tendon elongation occur in patients recovering from an Achilles tendon rupture.

    PubMed

    Silbernagel, Karin Grävare; Steele, Robert; Manal, Kurt

    2012-07-01

    Whether an Achilles tendon rupture is treated surgically or not, complications such as muscle weakness, decrease in heel-rise height, and gait abnormalities persist after injury. The purpose of this study was to evaluate if side-to-side differences in maximal heel-rise height can be explained by differences in Achilles tendon length. Case series; level of evidence, 4. Eight patients (mean [SD] age of 46 [13] years) with acute Achilles tendon rupture and 10 healthy subjects (mean [SD] age of 28 [8] years) were included in the study. Heel-rise height, Achilles tendon length, and patient-reported outcome were measured 3, 6, and 12 months after injury. Achilles tendon length was evaluated using motion analysis and ultrasound imaging. The Achilles tendon length test-retest reliability (intraclass correlation coefficient = 0.97) was excellent. For the healthy subjects, there were no side-to-side differences in tendon length and heel-rise height. Patients with Achilles tendon ruptures had significant differences between the injured and uninjured side for both tendon length (mean [SD] difference, 2.6-3.1 [1.2-1.4] cm, P = .017-.028) and heel-rise height (mean [SD] difference, -4.1 to -6.1 [1.7-1.8] cm, P = .012-.028). There were significant negative correlations (r = -0.943, P = .002, and r = -0.738, P = .037) between the side-to-side difference in heel-rise height and Achilles tendon length at the 6- and 12-month evaluations, respectively. The side-to-side difference found in maximal heel-rise height can be explained by a difference in Achilles tendon length in patients recovering from an Achilles tendon rupture. Minimizing tendon elongation appears to be an important treatment goal when aiming for full return of function.

  4. Reconstruction of chronic achilles tendon rupture with the use of interposed tissue between the stumps.

    PubMed

    Yasuda, Toshito; Kinoshita, Mitsuo; Okuda, Ryuzo

    2007-04-01

    The gap between the tendon stumps in chronic Achilles tendon rupture has reportedly been filled with interposed scar tissue. In the authors' clinical experience, this interposed tissue is often thick and resists tension, so they considered it was possible to use the interposed tissue for reconstruction of Achilles tendon rupture. Scar tissue interposed between the tendon stumps has the capacity to form tendon-like repair tissue in patients with chronic Achilles tendon rupture. Case series; Level of evidence, 4. Six patients with chronic rupture of the Achilles tendon underwent tendon reconstruction with the use of interposed tissue between the stumps. The average time from the primary injury to surgery was 22 weeks (range, 9 to 30 weeks). Preoperative magnetic resonance imaging (MRI), histology of the interposed tissue, and clinical results were evaluated. The average postoperative follow-up period was 31 months (range, 24 to 43 months). Preoperative T2-weighted MRI in all cases revealed that chronically ruptured Achilles tendons were thickened and fusiform-shaped with diffuse intratendinous high-signal alterations throughout. Longitudinal high-signal bands were seen throughout the tendon, except at the musculotendinous junction and insertion on the calcaneus. Histologically, scar tissue interposed between the tendon stumps consisted of dense collagen fibers, and degenerative changes were not seen. After surgery, no patient had difficulty in walking or stair climbing, and all were able to perform a single-limb toe raise. The mean preoperative and postoperative American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scores were 88.2 and 98.3 points, respectively; the difference was statistically significant (P = .0277). Interposed tissue between the tendon stumps is suitable for repair of chronic Achilles tendon rupture if preoperative MRI shows a thickened fusiform-shaped Achilles tendon with diffuse intratendinous high-signal alterations throughout.

  5. The Achilles Tendon in Healthy Subjects: An Anthropometric and Ultrasound Mapping Study.

    PubMed

    Patel, Nick N; Labib, Sameh A

    Ultrasonography is an inexpensive, fast, and reliable imaging technique widely used to assess the Achilles tendon. Although significant data exists regarding pathologic tendon changes, ultrasound data from healthy individuals are more limited. We aimed to better characterize ultrasound Achilles tendon measurements in healthy individuals and identify important correlating factors. The information collected included patient demographics, body habitus, activity level, foot dominance, and resting ankle angle. Ultrasound analysis was performed bilaterally on the Achilles tendons of 50 subjects using a high-frequency transducer to measure tendon width, thickness, cross-sectional area, and length. Males had a significantly larger mean tendon length, width, thickness, and cross-sectional area. No statistically significant difference was found in any tendon dimension between the white and black participants. Similarly, no difference was found in any tendon parameter when comparing right versus left leg dominance. Healthy subjects had a mean ankle resting angle of 45.1° ± 24° with no statistically significant difference between right and left ankles. Considering all individuals, each tendon parameter (tendon length, width, thickness, and cross-sectional area) correlated positively with subject height, weight, tibia length, and foot size. Only the Achilles cross-sectional area correlated significantly with the activity level. The resting angle of the ankle correlated positively with both tendon length and thickness. In conclusion, we found significant variations in Achilles tendon anatomy in the healthy adult population. We have thoroughly characterized significant correlations between healthy tendon dimensions and various body habitus, activity levels, and ankle parameters. Greater knowledge of the normal Achilles tendon anatomy and characterization of its variations in the healthy population will potentially allow for better pathologic diagnosis and surgical repair. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. The flexor digitorum profundus "demi-tendon"--a new technique for passage of the flexor profundus tendon through the A4 pulley.

    PubMed

    Elliot, D; Khandwala, A R; Ragoowansi, R

    2001-10-01

    The flexor digitorum profundus (FDP) tendon may retract after avulsion or division in Zone 1. When treatment has been delayed, the oedematous tendon can be too swollen to pass freely through the A4 pulley. We present a new technique for dealing with this situation which depends on the "double-barrelled" nature of the distal part of the FDP tendon. One half of the tendon is excised longitudinally and the remaining "demi-tendon" is passed through the intact A4 pulley to allow tendon repair or re-attachment. This technique has been used in six cases in which passage of the FDP tendon through the A4 pulley would otherwise have been impossible. Copyright 2001 The British Society for Surgery of the Hand.

  7. [Ultrastructural observation of tendonization of artificial tendon 109HH in rabbit].

    PubMed

    Liu, L; Cao, Q; Xiao, H

    1995-09-01

    Ten New Zealand rabbits were divided into 5 groups at random. Calcaneal tendons were cut bilaterally, then atificial tendon 109HH was used to connect the two ends of the cut tendon. Ultrastructural changes of control group and experimental groups at 2, 6, 12, 28 weeks after section were observed. The results showed that fibroblast proliferated and a lot of ribosome and RER appeared in plasm during 2 approximately 6 weeks, indicating artificial tendon caused fibroblast proliferation. During this period, fibroblast over synthesized collagenous protein and the synthesis of collagenous fibers peaked. During 12-28 weeks, the number of fibroblasts and the synthesis of collagenous protein decreased. Finally, fibroblasts became inactive tendon cells. With the formation of new tendons, the artificial tendens were degradated and absorbed, and disappeared after 12 weeks. The new tendon fibers became thicker and had the correct direction through reconstruction. The structure and function of new tendons could be restored to be consistent with normal values.

  8. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    PubMed

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  9. Tension is required for fibripositor formation.

    PubMed

    Kapacee, Zoher; Richardson, Susan H; Lu, Yinhui; Starborg, Tobias; Holmes, David F; Baar, Keith; Kadler, Karl E

    2008-05-01

    Embryonic tendon cells (ETCs) have actin-rich fibripositors that accompany parallel bundles of collagen fibrils in the extracellular matrix. To study fibripositor function, we have developed a three-dimensional cell culture system that promotes and maintains fibripositors. We show that ETCs cultured in fixed-length fibrin gels replace the fibrin during ~6 days in culture with parallel bundles of narrow-diameter collagen fibrils that are uniaxially aligned with fibripositors, thereby generating a tendon-like construct. Fibripositors occurred simultaneously with onset of parallel collagen fibrils. Interestingly, the constructs have a tendon-like crimp. In initial experiments to study the effects of tension, we showed that cutting the constructs resulted in loss of tension, loss of fibripositors and the appearance of immature fibrils with no preferred orientation.

  10. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.

    2011-02-01

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincaré sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  11. Optic axis determination by fiber-based polarization-sensitive swept-source optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.

    2011-03-01

    We describe a fiber-based variable-incidence-angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3-D optical axis of birefringent biological tissues. Single-plane VIAPS- OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fiber on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fiber. A proposed algorithm based on the angle between Stokes vectors on the Poincaré sphere is confirmed to work for all settings of the sample arm fiber. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  12. Angiogenesis in healing autogenous flexor-tendon grafts.

    PubMed

    Gelberman, R H; Chu, C R; Williams, C S; Seiler, J G; Amiel, D

    1992-09-01

    On the basis of recent evidence that flexor tendon grafts may heal without the ingrowth of vascular adhesions, eighteen autogenous donor tendons of intrasynovial and extrasynovial origin were transferred to the synovial sheaths in the forepaws of nine dogs, and controlled passive mobilization was instituted early in the postoperative period. The angiogenic responses of the tendon grafts were determined with perfusion studies with India ink followed by cleaing of the tissues with the Spalteholz technique at two, four, and six weeks. A consistent pattern of neovascularization was noted in the donor tendons of extrasynovial origin. Vascular adhesions arising from the flexor digitorum superficialis and the tendon sheath enveloped the tendon grafts by two weeks. By six weeks, the vascularity of the tendon grafts of extrasynovial origin appeared completely integrated with that of the surrounding tissues. Examination of cross sections revealed that the segments of tendon had been completely vascularized by obliquely oriented intratendinous vessels. In contrast, the flexor tendon grafts of intrasynovial origin healed without ingrowth of vascular adhesions. Primary intrinsic neovascularization took place from the proximal and, to a lesser extent, distal sites of the sutures. Examination of cross sections revealed vessels extending through the surface layer of the tendon graft, with small vessels penetrating the interior of the tendons at regular intervals.

  13. MRI in patients with chronic pubalgia: Is precise useful information provided to the surgeon? A case-control study.

    PubMed

    Larbi, A; Pesquer, L; Reboul, G; Omoumi, P; Perozziello, A; Abadie, P; Loriaut, P; Copin, P; Ducouret, E; Dallaudière, B

    2016-10-01

    Recent studies described that MRI is a good examination to assess damage in chronic athletic pubalgia (AP). However, to our knowledge, no studies focus on systematic correlation of precise tendon or parietal lesion in MRI with surgery and histological assessment. Therefore, we performed a case-control study to determine if MRI can precisely assess Adductor longus (AL) tendinopathy and parietal lesion, compared with surgery and histology. MRI can determine if AP comes from pubis symphysis, musculotendinous or inguinal orifice structures. Eighteen consecutive patients were enrolled from November 2011 to April 2013 for chronic AP. To constitute a control group, we also enrolled 18 asymptomatic men. All MRI were reviewed in consensus by 2 skeletal radiologists for pubic symphysis, musculotendinous, abdominal wall assessment and compared to surgery and histology findings. Regarding pubis symphysis, we found 4 symmetric bone marrow oedema (14%), 2 secondary cleft (7%) and 2 superior ligaments lesions (7%). For AL tendon, we mainly found 13 asymmetric bone marrow oedema (46%), 15 hyperaemia (54%). Regarding abdominal wall, the deep inguinal orifice size in the group of symptomatic athletes and the control group was respectively 27.3±6.4mm and 23.8±6.3mm. The correlation between MRI and surgery/histology was low: 20% for the AL tendon and 9% for the abdominal wall. If we chose the criteria "affected versus unaffected", this correlation became higher: 100% for AL tendon and 73% for the abdominal wall. MRI chronic athletic pubalgia concerns preferentially AL tendinopathy and deep inguinal canal dehiscence with high correlation to surgery/histology when only considering the item "affected versus unaffected" despite low correlation when we try to precisely grade these lesions. III: case-control study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Postinjury biomechanics of Achilles tendon vary by sex and hormone status

    PubMed Central

    Fryhofer, George W.; Freedman, Benjamin R.; Hillin, Cody D.; Salka, Nabeel S.; Pardes, Adam M.; Weiss, Stephanie N.; Farber, Daniel C.

    2016-01-01

    Achilles tendon ruptures are common injuries. Sex differences are present in mechanical properties of uninjured Achilles tendon, but it remains unknown if these differences extend to tendon healing. We hypothesized that ovariectomized females (OVX) and males would exhibit inferior postinjury tendon properties compared with females. Male, female, and OVX Sprague-Dawley rats (n = 32/group) underwent acclimation and treadmill training before blunt transection of the Achilles tendon midsubstance. Injured hindlimbs were immobilized for 1 wk, followed by gradual return to activity and assessment of active and passive hindlimb function. Animals were euthanized at 3 or 6 wk postinjury to assess tendon structure, mechanics, and composition. Passive ankle stiffness and range of motion were superior in females at 3 wk; however, by 6 wk, passive and active function were similar in males and females but remained inferior in OVX. At 6 wk, female tendons had greater normalized secant modulus, viscoelastic behavior, and laxity compared with males. Normalized secant modulus, cross-sectional area and tendon glycosaminoglycan composition were inferior in OVX compared with females at 6 wk. Total fatigue cycles until tendon failure were similar among groups. Postinjury muscle fiber size was better preserved in females compared with males, and females had greater collagen III at the tendon injury site compared with males at 6 wk. Despite male and female Achilles tendons withstanding similar durations of fatigue loading, early passive hindlimb function and tendon mechanical properties, including secant modulus, suggest superior healing in females. Ovarian hormone loss was associated with inferior Achilles tendon healing. PMID:27633741

  15. The effect of mechanical stimulation on the maturation of TDSCs-poly(L-lactide-co-e-caprolactone)/collagen scaffold constructs for tendon tissue engineering.

    PubMed

    Xu, Yuan; Dong, Shiwu; Zhou, Qiang; Mo, Xiumei; Song, Lei; Hou, Tianyong; Wu, Jinglei; Li, Songtao; Li, Yudong; Li, Pei; Gan, Yibo; Xu, Jianzhong

    2014-03-01

    Mechanical stimulation plays an important role in the development and remodeling of tendons. Tendon-derived stem cells (TDSCs) are an attractive cell source for tendon injury and tendon tissue engineering. However, these cells have not yet been fully explored for tendon tissue engineering application, and there is also lack of understanding to the effect of mechanical stimulation on the maturation of TDSCs-scaffold construct for tendon tissue engineering. In this study, we assessed the efficacy of TDSCs in a poly(L-lactide-co-ε-caprolactone)/collagen (P(LLA-CL)/Col) scaffold under mechanical stimulation for tendon tissue engineering both in vitro and in vivo, and evaluated the utility of the transplanted TDSCs-scaffold construct to promote rabbit patellar tendon defect regeneration. TDSCs displayed good proliferation and positive expressed tendon-related extracellular matrix (ECM) genes and proteins under mechanical stimulation in vitro. After implanting into the nude mice, the fluorescence imaging indicated that TDSCs had long-term survival, and the macroscopic evaluation, histology and immunohistochemistry examinations showed high-quality neo-tendon formation under mechanical stimulation in vivo. Furthermore, the histology, immunohistochemistry, collagen content assay and biomechanical testing data indicated that dynamically cultured TDSCs-scaffold construct could significantly contributed to tendon regeneration in a rabbit patellar tendon window defect model. TDSCs have significant potential to be used as seeded cells in the development of tissue-engineered tendons, which can be successfully fabricated through seeding of TDSCs in a P(LLA-CL)/Col scaffold followed by mechanical stimulation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. [Clinical application of peroneal muscles tendon transposition in repair of Achilles tendon rupture].

    PubMed

    Jin, Rihao; Jin, Yu; Fang, Xiulin

    2006-07-01

    To discuss applied anatomy, biomechanics and surgical procedures of long peroneal muscles tendon transposition in repair of occlusive achilles tendon rupture. The blood supply and the morphology of long peroneal muscles tendon were observed in the lower extremity of 50 sides adult specimens and the mechanical tests which stretch load on the tendon were carried out. The methods were designed on the basis of the anatomical characteristics and morphology. Ten patients suffering occlusive Achilles tendon rupture were treated by using long peroneal muscles tendon transposition from March 2001 to July 2004. Among 10 patients, there were 7 males and 3 females, aging 32 to 54 years including 6 cases of jump injury, 2 cases of bruise, 1 case of step vacancy and 1 case of spontaneity injury. The interval between injury and surgery was 6 hours to 7 days in 7 fresh rupture and 21 days to 3 months in 3 old rupture. All cases belonged to occlusive Achilles tendon rupture (8 cases of complete rupture and 2 cases of incomplete rupture). The origin of long peroneal muscles was proximal tibia and fibular head, the end of them was base of first metatarsal bones and medial cuboid. The length of tendon was 13.5 +/- 2.5 cm. The width of origin tendon was 0.9 +/- 0.2 cm and the thickness was 0.3 +/- 0.1 cm; the width on apex of lateral malleolus was 0.7 +/- 0.1 cm and the thickness was 0.4 +/- 0.1 cm, the width on head of cuboid was 0.7 +/- 0.1 cm and the thickness was 0.3 +/- 0.1 cm. The long peroneal muscles tendon had abundant blood supply. The results of mechanical test showed that the biggest load was 2,292.4 +/- 617.3 N on tendon calcaneus, 1,020.4 +/- 175.4 N on long peroneal muscles tendon, 752.0 +/- 165.4 N on peroneus brevis tendon and 938.2 +/- 216.7 N on tibialis posterior tendon. Ten cases of occlusive Achilles tendon rupture achieved healing by first intention and were followed up 18-24 months. No Achilles tendon re-rupture, necrosis of skin or other complications occurred. According to Amerind-holm criterion for curative results, the results were excellent in 7 cases and good in 3 cases and the excellent and good rate was 100%. The long peroneal muscles tendon transposition is a perfect and simple way to repair occlusive Achilles tendon rupture.

  17. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts.

    PubMed

    Wu, J H; Thoreson, A R; Gingery, A; An, K N; Moran, S L; Amadio, P C; Zhao, C

    2017-03-01

    The present study describes a novel technique for revitalising allogenic intrasynovial tendons by combining cell-based therapy and mechanical stimulation in an ex vivo canine model. Specifically, canine flexor digitorum profundus tendons were used for this study and were divided into the following groups: (1) untreated, unprocessed normal tendon; (2) decellularised tendon; (3) bone marrow stromal cell (BMSC)-seeded tendon; and (4) BMSC-seeded and cyclically stretched tendon. Lateral slits were introduced on the tendon to facilitate cell seeding. Tendons from all four study groups were distracted by a servohydraulic testing machine. Tensile force and displacement data were continuously recorded at a sample rate of 20 Hz until 200 Newton of force was reached. Before testing, the cross-sectional dimensions of each tendon were measured with a digital caliper. Young's modulus was calculated from the slope of the linear region of the stress-strain curve. The BMSCs were labeled for histological and cell viability evaluation on the decellularized tendon scaffold under a confocal microscope. Gene expression levels of selected extracellular matrix tendon growth factor genes were measured. Results were reported as mean ± SD and data was analyzed with one-way ANOVAs followed by Tukey's post hoc multiple-comparison test. We observed no significant difference in cross-sectional area or in Young's modulus among the four study groups. In addition, histological sections showed that the BMSCs were aligned well and viable on the tendon slices after two-week culture in groups three and four. Expression levels of several extracellular matrix tendon growth factors, including collagen type I, collagen type III, and matrix metalloproteinase were significantly higher in group four than in group three (p < 0.05). Lateral slits introduced into de-cellularised tendon is a promising method of delivery of BMSCs without compromising cell viability and tendon mechanical properties. In addition, mechanical stimulation of a cell-seeded tendon can promote cell proliferation and enhance expression of collagen types I and III in vitro . Cite this article: J. H. Wu, A. R. Thoreson, A. Gingery, K. N. An, S. L. Moran, P. C. Amadio, C. Zhao. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts. Bone Joint Res 2017;6:179-185. DOI: 10.1302/2046-3758.63.BJR-2016-0207.R1. © 2017 Zhao et al.

  18. The Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair

    PubMed Central

    Galloway, Marc T.; Lalley, Andrea L.; Shearn, Jason T.

    2013-01-01

    ➤ Tendon injuries often result from excessive or insufficient mechanical loading, impairing the ability of the local tendon cell population to maintain normal tendon function. ➤ The resident cell population composing tendon tissue is mechanosensitive, given that the cells are able to alter the extracellular matrix in response to modifications of the local loading environment. ➤ Natural tendon healing is insufficient, characterized by improper collagen fibril diameter formation, collagen fibril distribution, and overall fibril misalignment. ➤ Current tendon repair rehabilitation protocols focus on implementing early, well-controlled eccentric loading exercises to improve repair outcome. ➤ Tissue engineers look toward incorporating mechanical loading regimens to precondition cell populations for the creation of improved biological augmentations for tendon repair. PMID:24005204

  19. Therapeutics for tendon regeneration: a multidisciplinary review of tendon research for improved healing.

    PubMed

    Paredes, J J; Andarawis-Puri, Nelly

    2016-11-01

    Tendon injuries, known as tendinopathies, are common musculoskeletal injuries that affect a wide range of the population. Canonical tendon healing is characterized by fibrosis, scar formation, and the loss of tissue mechanical and structural properties. Understanding the regenerative tendon environment is an area of increasing interest in the field of musculoskeletal research. Previous studies have focused on utilizing individual elements from the fields of biomechanics, developmental biology, cell and growth factor therapy, and tissue engineering in an attempt to develop regenerative tendon therapeutics. Still, the specific mechanism for regenerative healing remains unknown. In this review, we highlight some of the current approaches of tendon therapeutics and elucidate the differences along the tendon midsubstance and enthesis, exhibiting the necessity of location-specific tendon therapeutics. Furthermore, we emphasize the necessity of further interdisciplinary research in order to reach the desired goal of fully understanding the mechanisms underlying regenerative healing. © 2016 New York Academy of Sciences.

  20. Peroneal tendon pathology: Pre- and post-operative high resolution US and MR imaging.

    PubMed

    Kumar, Yogesh; Alian, Ali; Ahlawat, Shivani; Wukich, Dane K; Chhabra, Avneesh

    2017-07-01

    Peroneal tendon pathology is an important cause of lateral ankle pain and instability. Typical peroneal tendon disorders include tendinitis, tenosynovitis, partial and full thickness tendon tears, peroneal retinacular injuries, and tendon subluxations and dislocations. Surgery is usually indicated when conservative treatment fails. Familiarity with the peroneal tendon surgeries and expected postoperative imaging findings is essential for accurate assessment and to avoid diagnostic pitfalls. Cross-sectional imaging, especially ultrasound and MRI provide accurate pre-operative and post-operative evaluation of the peroneal tendon pathology. In this review article, the normal anatomy, clinical presentation, imaging features, pitfalls and commonly performed surgical treatments for peroneal tendon abnormalities will be reviewed. The role of dynamic ultrasound and kinematic MRI for the evaluation of peroneal tendons will be discussed. Normal and abnormal postsurgical imaging appearances will be illustrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Mechanisms of tendon injury and repair

    PubMed Central

    Thomopoulos, Stavros; Parks, William C.; Rifkin, Daniel B.; Derwin, Kathleen A.

    2015-01-01

    Tendon disorders are common and lead to significant disability, pain, healthcare cost, and lost productivity. A wide range of injury mechanisms exist leading to tendinopathy or tendon rupture. Tears can occur in healthy tendons that are acutely overloaded (e.g., during a high speed or high impact event) or lacerated (e.g., a knife injury). Tendinitis or tendinosis can occur in tendons exposed to overuse conditions (e.g., an elite swimmer’s training regimen) or intrinsic tissue degeneration (e.g., age-related degeneration). The healing potential of a torn or pathologic tendon varies depending on anatomic location (e.g., Achilles vs. rotator cuff) and local environment (e.g., intrasynovial vs. extrasynovial). Although healing occurs to varying degrees, in general healing of repaired tendons follows the typical wound healing course, including an early inflammatory phase, followed by proliferative and remodeling phases. Numerous treatment approaches have been attempted to improve tendon healing, including growth factor- and cell-based therapies and rehabilitation protocols. This review will describe the current state of knowledge of injury and repair of the three most common tendinopathies-- flexor tendon lacerations, Achilles tendon rupture, and rotator cuff disorders-- with a particular focus on the use of animal models for understanding tendon healing. PMID:25641114

  2. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    PubMed

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p < 0.001). Only twelve (10.2%) of the 118 cases of peroneal tendon displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  3. Continuous Shear Wave Elastography: a New Method to Measure in-vivo Viscoelastic Properties of Tendons

    PubMed Central

    Cortes, Daniel H.; Suydam, Stephen M.; Silbernagel, Karin Grävare; Buchanan, Thomas S.; Elliott, Dawn M.

    2015-01-01

    Viscoelastic mechanical properties are frequently altered after tendon injuries and during recovery. Therefore, non-invasive measurements of shear viscoelastic properties may help evaluate tendon recovery and compare the effectiveness of different therapies. The objectives of this study are to present an elastography method to measure localized viscoelastic properties of tendon and to present initial results in healthy and injured human Achilles and semitendinosus tendons. The technique used an external actuator to generate the shear waves in the tendon at different frequencies and plane wave imaging to measure shear wave displacements. For each of the excitation frequencies, maps of direction specific wave speeds were calculated using Local Frequency Estimation. Maps of viscoelastic properties were obtained using a pixel wise curve-fit of wave speed and frequency. The method was validated by comparing measurements of wave speed in agarose gels to those obtained using magnetic resonance elastography. Measurements in human healthy Achilles tendons revealed a pronounced increase in wave speed as function of frequency that highlights the importance of tendon viscoelasticity. Additionally, the viscoelastic properties of the Achilles tendon were larger than those reported for other tissues. Measurements in a tendinopathic Achilles tendon showed that it is feasible to quantify local viscoeasltic properties. Similarly, measurement in the semitendinosus tendon showed a substantial differences in viscoelastic properties between the healthy and contralateral tendons. Consequently, this technique has the potential of evaluating localized changes in tendon viscoelastic properties due to injury and during recovery in a clinical setting. PMID:25796414

  4. An Overview of the Management of Flexor Tendon Injuries

    PubMed Central

    Griffin, M; Hindocha, S; Jordan, D; Saleh, M; Khan, W

    2012-01-01

    Flexor tendon injuries still remain a challenging condition to manage to ensure optimal outcome for the patient. Since the first flexor tendon repair was described by Kirchmayr in 1917, several approaches to flexor tendon injury have enabled successful repairs rates of 70-90%. Primary surgical repair results in better functional outcome compared to secondary repair or tendon graft surgery. Flexor tendon injury repair has been extensively researched and the literature demonstrates successful repair requires minimal gapping at the repair site or interference with tendon vascularity, secure suture knots, smooth junction of tendon end and having sufficient strength for healing. However, the exact surgical approach to achieve success being currently used among surgeons is still controversial. Therefore, this review aims to discuss the results of studies demonstrating the current knowledge regarding the optimal approach for flexor tendon repair. Post-operative rehabilitation for flexor tendon surgery is another area, which has caused extensive debate in hand surgery. The trend to more active mobilisation protocols seems to be favoured but further study in this area is needed to find the protocol, which achieves function and gliding but avoids rupture of the tendons. Lastly despite success following surgery complications commonly still occur post surgery, including adhesion formation, tendon rupture and stiffness of the joints. Therefore, this review aims to discuss the appropriate management of these difficulties post surgery. New techniques in management of flexor tendon will also be discussed including external laser devices, addition of growth factors and cytokines. PMID:22431948

  5. Effect of Implanting a Soft Tissue Autograft in a Central-Third Patellar Tendon Defect: Biomechanical and Histological Comparisons

    PubMed Central

    Kinneberg, Kirsten R. C.; Galloway, Marc T.; Butler, David L.; Shearn, Jason T.

    2011-01-01

    Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon auto-graft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to bio-mechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model. [DOI: 10.1115/1.4004948] PMID:22010737

  6. Micro-mechanical properties of the tendon-to-bone attachment.

    PubMed

    Deymier, Alix C; An, Yiran; Boyle, John J; Schwartz, Andrea G; Birman, Victor; Genin, Guy M; Thomopoulos, Stavros; Barber, Asa H

    2017-07-01

    The tendon-to-bone attachment (enthesis) is a complex hierarchical tissue that connects stiff bone to compliant tendon. The attachment site at the micrometer scale exhibits gradients in mineral content and collagen orientation, which likely act to minimize stress concentrations. The physiological micromechanics of the attachment thus define resultant performance, but difficulties in sample preparation and mechanical testing at this scale have restricted understanding of structure-mechanical function. Here, microscale beams from entheses of wild type mice and mice with mineral defects were prepared using cryo-focused ion beam milling and pulled to failure using a modified atomic force microscopy system. Micromechanical behavior of tendon-to-bone structures, including elastic modulus, strength, resilience, and toughness, were obtained. Results demonstrated considerably higher mechanical performance at the micrometer length scale compared to the millimeter tissue length scale, describing enthesis material properties without the influence of higher order structural effects such as defects. Micromechanical investigation revealed a decrease in strength in entheses with mineral defects. To further examine structure-mechanical function relationships, local deformation behavior along the tendon-to-bone attachment was determined using local image correlation. A high compliance zone near the mineralized gradient of the attachment was clearly identified and highlighted the lack of correlation between mineral distribution and strain on the low-mineral end of the attachment. This compliant region is proposed to act as an energy absorbing component, limiting catastrophic failure within the tendon-to-bone attachment through higher local deformation. This understanding of tendon-to-bone micromechanics demonstrates the critical role of micrometer scale features in the mechanics of the tissue. The tendon-to-bone attachment (enthesis) is a complex hierarchical tissue with features at a numerous scales that dissipate stress concentrations between compliant tendon and stiff bone. At the micrometer scale, the enthesis exhibits gradients in collagen and mineral composition and organization. However, the physiological mechanics of the enthesis at this scale remained unknown due to difficulty in preparing and testing micrometer scale samples. This study is the first to measure the tensile mechanical properties of the enthesis at the micrometer scale. Results demonstrated considerably enhanced mechanical performance at the micrometer length scale compared to the millimeter tissue length scale and identified a high-compliance zone near the mineralized gradient of the attachment. This understanding of tendon-to-bone micromechanics demonstrates the critical role of micrometer scale features in the mechanics of the tissue. Copyright © 2017. Published by Elsevier Ltd.

  7. Mechanical Strength of the Side-to-Side Versus Pulvertaft Weave Tendon Repair

    PubMed Central

    Brown, Stephen H. M.; Hentzen, Eric R.; Kwan, Alan; Ward, Samuel R.; Fridén, Jan; Lieber, Richard L.

    2010-01-01

    Purpose The side-to-side (SS) tendon suture technique was designed to function as a repair that permits immediate post-operative activation and mobilization of a transferred muscle. This study was designed to test the strength and stiffness of the SS technique against a variation of the Pulvertaft (PT) repair technique. Methods Flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) tendons were harvested from four fresh cadavers and used as a model system. Seven SS and six PT repairs were performed using the FDS as the donor and the FDP as the recipient tendon. For SS repairs, the FDS was woven through one incision in the FDP, and was joined with four cross-stitch running sutures down both sides, and one double-loop suture at each tendon free end; for PT repairs, FDS was woven through three incisions in FDP, joined with a double-loop suture at both ends of the overlap, and four evenly spaced mattress sutures between the ends. Tendon repairs were placed in a tensile testing machine, pre-conditioned and tested to failure. Results There were no statistically significant differences in cross-sectional area (p=0.99) or initial length (p=0.93) between SS and PT repairs. Therefore, all comparisons between methods were made using measures of loads and deformations, rather than stresses and strains.. All failures occurred in the repair region, rather than at the clamps. However, failure mechanisms were different between the two techniques—PT repairs failed by the suture knots either slipping or pulling through the tendon material, followed by the FDS tendon pulling through the FDP tendon; SS repairs failed by shearing of fibers within the FDS. Load at first failure (p < 0.01), ultimate load (p < 0.001), and repair stiffness (p < 0.05) were all significantly different between SS and PT techniques; in all cases the mean value for SS was higher than for PT. Discussion The SS repair, using a cross-stitch suture technique, was significantly stronger and stiffer compared to the PT repair using a mattress suture technique. This suggests that using SS repairs could enable patients to load the repair soon after surgery. Ultimately, this should reduce the risk of developing adhesions and result in improved functional outcome and fewer complications in the acute post-operative period. Future work will address the specific mechanisms (for example, suture-throw technique, tendon-weave technique) that underlie the improved strength and stiffness of the SS repair. PMID:20223604

  8. The 3-D vision system integrated dexterous hand

    NASA Technical Reports Server (NTRS)

    Luo, Ren C.; Han, Youn-Sik

    1989-01-01

    Most multifingered hands use a tendon mechanism to minimize the size and weight of the hand. Such tendon mechanisms suffer from the problems of striction and friction of the tendons resulting in a reduction of control accuracy. A design for a 3-D vision system integrated dexterous hand with motor control is described which overcomes these problems. The proposed hand is composed of three three-jointed grasping fingers with tactile sensors on their tips, a two-jointed eye finger with a cross-shaped laser beam emitting diode in its distal part. The two non-grasping fingers allow 3-D vision capability and can rotate around the hand to see and measure the sides of grasped objects and the task environment. An algorithm that determines the range and local orientation of the contact surface using a cross-shaped laser beam is introduced along with some potential applications. An efficient method for finger force calculation is presented which uses the measured contact surface normals of an object.

  9. Advances in biologic augmentation for rotator cuff repair

    PubMed Central

    Patel, Sahishnu; Gualtieri, Anthony P.; Lu, Helen H.; Levine, William N.

    2016-01-01

    Rotator cuff tear is a very common shoulder injury that often necessitates surgical intervention for repair. Despite advances in surgical techniques for rotator cuff repair, there is a high incidence of failure after surgery because of poor healing capacity attributed to many factors. The complexity of tendon-to-bone integration inherently presents a challenge for repair because of a large biomechanical mismatch between the tendon and bone and insufficient regeneration of native tissue, leading to the formation of fibrovascular scar tissue. Therefore, various biological augmentation approaches have been investigated to improve rotator cuff repair healing. This review highlights recent advances in three fundamental approaches for biological augmentation for functional and integrative tendon–bone repair. First, the exploration, application, and delivery of growth factors to improve regeneration of native tissue is discussed. Second, applications of stem cell and other cell-based therapies to replenish damaged tissue for better healing is covered. Finally, this review will highlight the development and applications of compatible biomaterials to both better recapitulate the tendon–bone interface and improve delivery of biological factors for enhanced integrative repair. PMID:27750374

  10. The promoting effect of pentadecapeptide BPC 157 on tendon healing involves tendon outgrowth, cell survival, and cell migration.

    PubMed

    Chang, Chung-Hsun; Tsai, Wen-Chung; Lin, Miao-Sui; Hsu, Ya-Hui; Pang, Jong-Hwei Su

    2011-03-01

    Pentadecapeptide BPC 157, composed of 15 amino acids, is a partial sequence of body protection compound (BPC) that is discovered in and isolated from human gastric juice. Experimentally it has been demonstrated to accelerate the healing of many different wounds, including transected rat Achilles tendon. This study was designed to investigate the potential mechanism of BPC 157 to enhance healing of injured tendon. The outgrowth of tendon fibroblasts from tendon explants cultured with or without BPC 157 was examined. Results showed that BPC 157 significantly accelerated the outgrowth of tendon explants. Cell proliferation of cultured tendon fibroblasts derived from rat Achilles tendon was not directly affected by BPC 157 as evaluated by MTT assay. However, the survival of BPC 157-treated cells was significantly increased under the H(2)O(2) stress. BPC 157 markedly increased the in vitro migration of tendon fibroblasts in a dose-dependent manner as revealed by transwell filter migration assay. BPC 157 also dose dependently accelerated the spreading of tendon fibroblasts on culture dishes. The F-actin formation as detected by FITC-phalloidin staining was induced in BPC 157-treated fibroblasts. The protein expression and activation of FAK and paxillin were determined by Western blot analysis, and the phosphorylation levels of both FAK and paxillin were dose dependently increased by BPC 157 while the total amounts of protein was unaltered. In conclusion, BPC 157 promotes the ex vivo outgrowth of tendon fibroblasts from tendon explants, cell survival under stress, and the in vitro migration of tendon fibroblasts, which is likely mediated by the activation of the FAK-paxillin pathway.

  11. Partial supraspinatus tears are associated with tendon lengthening.

    PubMed

    Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian

    2015-02-01

    Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.

  12. Experimental evaluation of multiscale tendon mechanics.

    PubMed

    Fang, Fei; Lake, Spencer P

    2017-07-01

    Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    PubMed

    Thangarajah, Tanujan; Shahbazi, Shirin; Pendegrass, Catherine J; Lambert, Simon; Alexander, Susan; Blunn, Gordon W

    2016-01-01

    Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds. In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5), or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5) were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery. Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047), 9 (P = 0.028), and 12 weeks (P = 0.009). In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015), and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039). No failures of tendon-bone healing were noted in either group. Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  14. The biomechanical effects of limb lengthening and botulinum toxin type A on rabbit tendon.

    PubMed

    Olabisi, Ronke M; Best, Thomas M; Hurschler, Christof; Vanderby, Ray; Noonan, Kenneth J

    2010-12-01

    Numerous studies have examined the effects of distraction osteogenesis (DO) on bone, but relatively fewer have explored muscle adaptation, and even less have addressed the concomitant alterations that occur in the tendon. The purpose herein was to characterize the biomechanical properties of normal and elongated rabbit (N = 20) tendons with and without prophylactic botulinum toxin type A (BTX-A) treatment. Elastic and viscoelastic properties of Achilles and Tibialis anterior (TA) tendons were evaluated through pull to failure and stress relaxation tests. All TA tendons displayed nonlinear viscoelastic responses that were strain dependent. A power law formulation was used to model tendon viscoelastic responses and tendon elastic responses were fit with a microstructural model. Distraction-elongated tendons displayed increases in compliance and stress relaxation rates over undistracted tendons; BTX-A administration offset this result. The elastic moduli of distraction-lengthened TA tendons were diminished (p = 0.010) when distraction was combined with gastrocnemius (GA) BTX-A administration, elastic moduli were further decreased (p = 0.004) and distraction following TA BTX-A administration resulted in TA tendons with moduli not different from contralateral control (p > 0.05). Compared to contralateral control, distraction and GA BTX-A administration displayed shortened toe regions, (p = 0.031 and 0.038, respectively), while tendons receiving BTX-A in the TA had no differences in the toe region (p > 0.05). Ultimate tensile stress was unaltered by DO, but stress at the transition from the toe to the linear region of the stress-stretch curve was diminished in all distraction-elongated TA tendons (p < 0.05). The data suggest that prophylactic BTX-A treatment to the TA protects some tendon biomechanical properties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    PubMed

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Functional tissue engineering of tendon: Establishing biological success criteria for improving tendon repair.

    PubMed

    Breidenbach, Andrew P; Gilday, Steven D; Lalley, Andrea L; Dyment, Nathaniel A; Gooch, Cynthia; Shearn, Jason T; Butler, David L

    2014-06-27

    Improving tendon repair using Functional Tissue Engineering (FTE) principles has been the focus of our laboratory over the last decade. Although our primary goals were initially focused only on mechanical outcomes, we are now carefully assessing the biological properties of our tissue-engineered tendon repairs so as to link biological influences with mechanics. However, given the complexities of tendon development and healing, it remains challenging to determine which aspects of tendon biology are the most important to focus on in the context of tissue engineering. To address this problem, we have formalized a strategy to identify, prioritize, and evaluate potential biological success criteria for tendon repair. We have defined numerous biological properties of normal tendon relative to cellular phenotype, extracellular matrix and tissue ultra-structure that we would like to reproduce in our tissue-engineered repairs and prioritized these biological criteria by examining their relative importance during both normal development and natural tendon healing. Here, we propose three specific biological criteria which we believe are essential for normal tendon function: (1) scleraxis-expressing cells; (2) well-organized and axially-aligned collagen fibrils having bimodal diameter distribution; and (3) a specialized tendon-to-bone insertion site. Moving forward, these biological success criteria will be used in conjunction with our already established mechanical success criteria to evaluate the effectiveness of our tissue-engineered tendon repairs. © 2013 Published by Elsevier Ltd.

  17. The Quadriga Effect Revisited: Designing a “Safety Incision” to Prevent Tendon Repair Rupture and Gap Formation in a Canine Model In Vitro

    PubMed Central

    Giambini, Hugo; Ikeda, Jun; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2012-01-01

    Loss of experimental animals due to tendon repair failure results in the need for additional animals to complete the study. We designed a relief proximal to the flexor digitorum profundus (FDP) tendon repair site to serve as a “safety incision” to prevent repair site ruptures and maximize safety incision-to-suture strength. The FDP tendons were dissected in 24 canine forepaws. The 2nd and 5th tendons were lacerated at the proximal interphalangeal joint level and sutured using a modified Kessler technique and peripheral running suture. Tendon width was measured where the FDP tendon separates into each individual digit and a safety incision, equal to the 2nd and 5th tendon widths, was performed 3, 4, or 5 mm (Groups 1, 2, and 3) proximal to the separation. The tendons were pulled at a rate of 1 mm/s until either the “safety incision” ruptured or the repair failed. There was no gap formation at the repair site in Groups 1 and 2. However, all Group 3 tendons failed by repair site rupture with the safety incision intact. An adequate safety incision to protect repair gap and rupture and maintain tendon tension for the FDP animal model should be about 4 mm from where the FDP tendon separates. PMID:20872585

  18. Characterising the proximal patellar tendon attachment and its relationship to skeletal maturity in adolescent ballet dancers

    PubMed Central

    Rudavsky, Aliza; Cook, Jillianne; Magnusson, Stig Peter; Kjaer, Michael; Docking, Sean

    2017-01-01

    Summary Background It is unknown how and when the proximal attachment of the patellar tendon matures; puberty may be key in ensuring normal tendon formation. The aim of this study was to investigate the features of the proximal patellar tendon attachment at different stages of skeletal maturity, to help gain an understanding of how and when the tendon attachment matures. Methods Sixty adolescent elite ballet students (ages 11–18) and eight mature adults participated. Peak height velocity (PHV) estimated skeletal maturity. Ultrasound tissue characterisation (UTC) scan was taken of the left knee and analysed for stability of echopattern. An image-based grading scale for greyscale ultrasound was developed to describe the tendon appearance. Anterior-posterior thickness was measured at the inferior pole of the patella, 1 and 2 centimetres distally. Outcomes were compared with skeletal maturity. Results Mid-portion patellar tendon thickness increased with skeletal maturity (p=0.001 at 1 cm and p=0.007 at 2 cm). There was more variance in structural appearance (greyscale classification and UTC echopattern) in pre and peri-PHV participants. Tendon attachment one-year post PHV appeared similar to mature tendons. Conclusions Early adolescence was associated with highly variable tendon appearance, whereas the tendon appeared mature after PHV. Adolescence may be a critical time for the formation of normal tendon attachment. Level of evidence IIb individual cohort study. PMID:29264342

  19. Greater glycosaminoglycan content in human patellar tendon biopsies is associated with more pain and a lower VISA score.

    PubMed

    Attia, Mohamed; Scott, Alexander; Carpentier, Gilles; Lian, Oystein; Van Kuppevelt, Toin; Gossard, Camille; Papy-Garcia, Dulce; Tassoni, Marie-Claude; Martelly, Isabelle

    2014-03-01

    People with patellar tendinopathy experience chronic pain and activity limitation, but a pertinent biochemical marker correlated with these clinical features has not been identified. The Victoria Institute of Sport Assessment (VISA) questionnaire is a condition-specific patient-rated outcome measure. Since the quantity of glycosaminoglycans (GAGs) increases with advancing tendon pathology, we hypothesised that there would be a correlation between the quantity of GAGs in the patellar tendon and the VISA score. Tissue biopsies from athletes with chronic patellar tendinopathy (confirmed by clinical examination and MRI) were recruited (n=7), as well as controls with no history of knee pain (n=4). The quantity of sulphated GAGs in the human patellar tendons was determined with a dimethyl methylene blue (DMMB) assay; this method was first validated with rat tendon tissue. The extent and distribution of GAG species and proteoglycans (decorin, versican and aggrecan) in the human tendon biopsies were examined using immunohistochemistry. Greater sulphated GAG content of the patellar tendon was correlated with the greater tendon dysfunction (R(2)=0.798). The quantity of aggrecan in the tendon, a chondroitin sulphate-rich proteoglycan, also increased with advancing tendon pathology. Increased GAGs in the pathological human patellar tendon are related to a worse clinical status. These findings indicate that the VISA score reflects the extent of tendon tissue pathology.

  20. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    PubMed Central

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  1. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    PubMed

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with MSCs have the potential to accelerate bone-tendon healing in ACL reconstruction. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Repair of chronic rupture of the achilles tendon using 2 intratendinous flaps from the proximal gastrocnemius-soleus complex.

    PubMed

    El Shewy, Mohamed Taha; El Barbary, Hassan Magdy; Abdel-Ghani, Hisham

    2009-08-01

    Chronic rupture of the Achilles tendon is a surgical challenge, owing to the presence of a gap between the retracted ends, which renders direct repair almost impossible. In this study, 2 intratendinous distally based flaps fashioned from the proximal gastrocnemiussoleus complex are used to bridge the gap between the retracted edges of the ruptured Achilles tendon. The flaps are placed in the same line of pull of the ruptured tendon, in an effort to make the graft mimic the original biomechanics as much as possible. Case series; Level of evidence, 4. Eleven patients (9 male and 2 female) with neglected ruptures of the Achilles tendon with retracted ends were included in this study. Two flaps fashioned from the proximal gastrocnemiussoleus complex were rotated over themselves, passed through the proximal stump, and then securely inserted into a previously prepared bed in the distal stump. The patients were followed up for a period of 6 to 9 years. At the final follow-up, all patients were able to return to their preinjury level of activity within a period of 6 to 9 months. The mean preoperative American Orthopedic Foot and Ankle Society score was 42.27, whereas it was 98.91 at the final follow-up, with a range of 88 (in 1 patient) to 100 points (in 10 patients). All 11 patients showed statistically significant improvement according to the Holz rating system. This technique allows for a bridging of the defect present in chronic ruptures of Achilles tendons, with a minimum of complications and a good final outcome.

  3. The series-elastic shock absorber: tendons attenuate muscle power during eccentric actions

    PubMed Central

    Azizi, Emanuel

    2010-01-01

    Elastic tendons can act as muscle power amplifiers or energy-conserving springs during locomotion. We used an in situ muscle-tendon preparation to examine the mechanical function of tendons during lengthening contractions, when muscles absorb energy. Force, length, and power were measured in the lateral gastrocnemius muscle of wild turkeys. Sonomicrometry was used to measure muscle fascicle length independently from muscle-tendon unit (MTU) length, as measured by a muscle lever system (servomotor). A series of ramp stretches of varying velocities was applied to the MTU in fully activated muscles. Fascicle length changes were decoupled from length changes imposed on the MTU by the servomotor. Under most conditions, muscle fascicles shortened on average, while the MTU lengthened. Energy input to the MTU during the fastest lengthenings was −54.4 J/kg, while estimated work input to the muscle fascicles during this period was only −11.24 J/kg. This discrepancy indicates that energy was first absorbed by elastic elements, then released to do work on muscle fascicles after the lengthening phase of the contraction. The temporary storage of energy by elastic elements also resulted in a significant attenuation of power input to the muscle fascicles. At the fastest lengthening rates, peak instantaneous power input to the MTU reached −2,143.9 W/kg, while peak power input to the fascicles was only −557.6 W/kg. These results demonstrate that tendons may act as mechanical buffers by limiting peak muscle forces, lengthening rates, and power inputs during energy-absorbing contractions. PMID:20507964

  4. The prevalence and clinical significance of sonographic tendon abnormalities in asymptomatic ballet dancers: a 24-month longitudinal study.

    PubMed

    Comin, Jules; Cook, Jill L; Malliaras, Peter; McCormack, Moira; Calleja, Michelle; Clarke, Andrew; Connell, David

    2013-01-01

    Sonographic abnormalities of the achilles and patellar tendons are common findings in athletes, and tendinopathy is a common cause of pain and disability in athletes. However, it is unclear whether the sonographic changes are pathological or adaptive, or if they predict future injury. We undertook a cohort study to determine what sonographic features of the achilles and patellar tendons are consistent with changes as a result of ballet training, and which may be predictive of future development of disabling tendon symptoms. The achilles and patellar tendons of 79 (35 male, 44 female) professional ballet dancers (members of the English Royal Ballet) were examined with ultrasound, measuring proximal and distal tendon diameters and assessing for the presence of hypoechoic change, intratendon defects, calcification and neovascularity. All subjects were followed for 24 months for the development of patellar tendon or achilles-related pain or injury severe enough to require time off from dancing. Sonographic abnormalities were common among dancers, both male and female, and in both achilles and patellar tendons. Disabling tendon-related symptoms developed in 10 dancers and 14 tendons: 7 achilles (3 right, 4 left) and 7 patellar (2 right, 5 left). The presence of moderate or severe hypoechoic defects was weakly predictive for the development of future disabling tendon symptoms (p=0.0381); there was no correlation between any of the other sonographic abnormalities and the development of symptoms. There was no relationship between achilles or patellar tendons' diameter, either proximal or distal, with an increased likelihood of developing tendon-related disability. The presence of sonographic abnormalities is common in ballet dancers, but only the presence of focal hypoechoic changes predicts the development of future tendon-related disability. This suggests that screening of asymptomatic individuals may be of use in identifying those who are at higher risk of developing tendon-related disability, which may in turn allow targeted modifications of training or other preventative regimens.

  5. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    PubMed

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  6. Effects of Increased Loading on In Vivo Tendon Properties: A Systematic Review

    PubMed Central

    WIESINGER, HANS-PETER; KÖSTERS, ALEXANDER; MÜLLER, ERICH; SEYNNES, OLIVIER R.

    2015-01-01

    ABSTRACT Introduction In vivo measurements have been used in the past two decades to investigate the effects of increased loading on tendon properties, yet the current understanding of tendon macroscopic changes to training is rather fragmented, limited to reports of tendon stiffening, supported by changes in material properties and/or tendon hypertrophy. The main aim of this review was to analyze the existing literature to gain further insights into tendon adaptations by extracting patterns of dose-response and time-course. Methods PubMed/Medline, SPORTDiscus, and Google Scholar databases were searched for studies examining the effect of training on material, mechanical, and morphological properties via longitudinal or cross-sectional designs. Results Thirty-five of 6440 peer-reviewed articles met the inclusion criteria. The key findings were i) the confirmation of a nearly systematic adaptation of tendon tissue to training, ii) the important variability in the observed changes in tendon properties between and within studies, and iii) the absence of a consistent incremental pattern regarding the dose-response or the time-course relation of tendon adaptation within the first months of training. However, long-term (years) training was associated with a larger tendon cross-sectional area, without any evidence of differences in material properties. Our analysis also highlighted several gaps in the existing literature, which may be addressed in future research. Conclusions In line with some cross-species observations about tendon design, tendon cross-sectional area allegedly constitutes the ultimate adjusting parameter to increased loading. We propose here a theoretical model placing tendon hypertrophy and adjustments in material properties as parts of the same adaptive continuum. PMID:25563908

  7. Continuous Shear Wave Elastography: A New Method to Measure Viscoelastic Properties of Tendons in Vivo.

    PubMed

    Cortes, Daniel H; Suydam, Stephen M; Silbernagel, Karin Grävare; Buchanan, Thomas S; Elliott, Dawn M

    2015-06-01

    Viscoelastic mechanical properties are frequently altered after tendon injuries and during recovery. Therefore, non-invasive measurements of shear viscoelastic properties may help evaluate tendon recovery and compare the effectiveness of different therapies. The objectives of this study were to describe an elastography method for measuring localized viscoelastic properties of tendons and to discuss the initial results in healthy and injured human Achilles and semitendinosus tendons. The technique used an external actuator to generate the shear waves in the tendon at different frequencies and plane wave imaging to measure shear wave displacements. For each of the excitation frequencies, maps of direction-specific wave speeds were calculated using local frequency estimation. Maps of viscoelastic properties were obtained using a pixel-wise curve fit of wave speed and frequency. The method was validated by comparing measurements of wave speed in agarose gels with those obtained using magnetic resonance elastography. Measurements in human healthy Achilles tendons revealed a pronounced increase in wave speed as a function of frequency, which highlights the importance of tendon viscoelasticity. Additionally, the viscoelastic properties of the Achilles tendon were larger than those reported for other tissues. Measurements in a tendinopathic Achilles tendon indicated that it is feasible to quantify local viscoelastic properties. Similarly, measurement in the semitendinosus tendon revealed substantial differences in viscoelastic properties between the healthy and contralateral tendons. Consequently, this technique has the potential to evaluate localized changes in tendon viscoelastic properties caused by injury and during recovery in a clinical setting. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Decellularized Tendon Extracellular Matrix—A Valuable Approach for Tendon Reconstruction?

    PubMed Central

    Schulze-Tanzil, Gundula; Al-Sadi, Onays; Ertel, Wolfgang; Lohan, Anke

    2012-01-01

    Tendon healing is generally a time-consuming process and often leads to a functionally altered reparative tissue. Using degradable scaffolds for tendon reconstruction still remains a compromise in view of the required high mechanical strength of tendons. Regenerative approaches based on natural decellularized allo- or xenogenic tendon extracellular matrix (ECM) have recently started to attract interest. This ECM combines the advantages of its intrinsic mechanical competence with that of providing tenogenic stimuli for immigrating cells mediated, for example, by the growth factors and other mediators entrapped within the natural ECM. A major restriction for their therapeutic application is the mainly cell-associated immunogenicity of xenogenic or allogenic tissues and, in the case of allogenic tissues, also the risk of disease transmission. A survey of approaches for tendon reconstruction using cell-free tendon ECM is presented here, whereby the problems associated with the decellularization procedures, the success of various recellularization strategies, and the applicable cell types will be thoroughly discussed. Encouraging in vivo results using cell-free ECM, as, for instance, in rabbit models, have already been reported. However, in comparison to native tendon, cells remain mostly inhomogeneously distributed in the reseeded ECM and do not align. Hence, future work should focus on the optimization of tendon ECM decellularization and recolonization strategies to restore tendon functionality. PMID:24710540

  9. [Rheumatic tendon pathologies].

    PubMed

    Thomas, M; Jordan, M

    2014-11-01

    Rheumatoid arthritis is found in approximately 2 % of the total population in Europe and the peak incidence of the disease is during the fourth and fifth decades of life. In approximately 15 % the first symptoms of the disease occur at the level of the foot and ankle. If the early stage-dependent therapy with pharmaceuticals fails isolated surgery of the tendons (e.g. tenosynovectomy) and reconstructive surgery including the tendons (e.g. tendon transfer and tendon readaptation) are performed to keep the patient mobile. The aim of this article is to give an overview of the most commonly used interventions in the reconstruction of tendons in rheumatism patients and the corresponding indications. The conservative therapy options for rheumatic foot and ankle alterations with a special emphasis on tendon pathologies have a well-established importance and are also presented. A selective literature search was carried out for therapeutic options of rheumatic tendon pathologies. If possible attempts should be made to preserve functional qualities using tenosynovectomy, tendon sutures or tendon transfer operations. If joints are already destroyed or dislocated, tendon operations should be carried out only as combined interventions with arthrodesis, endoprostheses or resection arthroplasty. The time window in which these interventions are possible should not be missed. Orthotic devices, bandages or even orthopedic shoes provide external support and splinting but do not represent a causal therapy.

  10. Magnetotherapy: The quest for tendon regeneration.

    PubMed

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  11. Mechanical Strength of the Side-to-Side Tendon Attachment for Mismatched Tendon Sizes and Shapes

    PubMed Central

    Fridén, Jan; Tirrell, Timothy F.; Bhola, Siddharth; Lieber, Richard L.

    2015-01-01

    Summary Certain combinations are advised against in tendon transfers due to size or shape mismatches between donor and recipient tendons. In this study, ultimate load, stiffness and Young’s modulus were measured in two tendon-to-tendon attachments with intentionally mismatched donor and recipient tendons - pronator teres (PT)-to-extensor carpi radialis brevis (ECRB) and flexor carpi ulnaris (FCU)-to-extensor digitorum communis (EDC). FCU-EDC attachments failed at higher loads than PT-to-ECRB attachments but they had similar modulus and stiffness values. Ultimate tensile strength of the tendon attachments exceeded the maximum predicted contraction force of any of the affected muscles, with safety factors of 4x and 2x for the FCU-to-EDC and PT-to-ECRB constructs, respectively. This implies that size and shape mismatch should not be a contraindication to tendon attachment in transfers. Further, these safety factors strongly suggest that no postoperative immobilization of these attachments is necessary. PMID:24413573

  12. Stem cell technology for tendon regeneration: current status, challenges, and future research directions

    PubMed Central

    Lui, Pauline Po Yee

    2015-01-01

    Tendon injuries are a common cause of physical disability. They present a clinical challenge to orthopedic surgeons because injured tendons respond poorly to current treatments without tissue regeneration and the time required for rehabilitation is long. New treatment options are required. Stem cell-based therapies offer great potential to promote tendon regeneration due to their high proliferative, synthetic, and immunomodulatory activities as well as their potential to differentiate to the target cell types and undergo genetic modification. In this review, I first recapped the challenges of tendon repair by reviewing the anatomy of tendon. Next, I discussed the advantages and limitations of using different types of stem cells compared to terminally differentiated cells for tendon tissue engineering. The safety and efficacy of application of stem cells and their modified counterparts for tendon tissue engineering were then summarized after a systematic literature search in PubMed. The challenges and future research directions to enhance, optimize, and standardize stem cell-based therapies for augmenting tendon repair were then discussed. PMID:26715856

  13. [Rupture of the Achilles tendon].

    PubMed

    Ulmar, B; Simon, S; Eschler, A; Mittlmeier, T

    2014-10-01

    The rupture of the Achilles tendon is the most frequent tendon rupture in humans and it is associated with increasing incidence. The main risk factor is intrinsic degeneration of the tendon. During the rupture the person feels a whiplash or dagger thrust-like pain, followed by restricted walking ability and decreased plantar flexion of the ankle. The positive Simmond/Thompson test and a palpable dent above the tendon rupture are pathognomical. Diagnostically, ultrasound of the tendon and lateral x-ray of the calcaneus (bony pull-out of the tendon insertion) are necessary. Regarding correct indication and treatment modalities, most established conservative and surgical therapies realize optimal functional results. Surgical treatment promises better primary stability and slightly earlier better functional results, but there is the potential for surgical complications. Conservative therapy is associated with higher rates of re-rupture and healing of the tendon under elongation. Therefore, therapy planning in Achilles tendon rupture should be determined based on each patient. We recommend surgical treatment in patients with higher sporting demands and in younger patients (< 50 years).

  14. Experimental study of the effects of helium-neon laser radiation on repair of injured tendon

    NASA Astrophysics Data System (ADS)

    Xu, Yong-Qing; Li, Zhu-Yi; Weng, Long-Jiang; An, Mei; Li, Kai-Yun; Chen, Shao-Rong; Wang, Jian-Xin; Lu, Yu

    1993-03-01

    Despite extensive research into the biology of tendon healing, predictably restoring normal function to a digit after a flexor tendon laceration remains one of the most difficult problems facing the hand surgeon. The challenge of simultaneously achieving tendon healing while minimizing the peritendinous scar formation, which limits tendon gliding, has captured the attention of investigators for many years. It has been said that low-power density helium-neon laser radiation had effects on anti-inflammation, detumescence, progressive wound healing, and reducing intestinal adhesions. This experimental study aims at whether helium-neon laser can reduce injured tendon adhesions and improve functional recovery of the injured tendon. Fifty white Leghorn hens were used. Ten were randomly assigned as a normal control group, the other forty were used in the operation. After anesthetizing them with Amytal, a half of the profundus tendons of the second and third foretoes on both sides of the feet were cut. Postoperatively, the hens moved freely in the cages. One side of the toes operated on were randomly chosen as a treatment group, the other side served as an untreated control group. The injured tendon toes in the treatment group were irradiated for twenty minutes daily with a fiber light needle of helium-neon laser therapeutic apparatus (wavelength, 6328 angstroms) at a constant power density of 12.74 mW/cm2, the first exposure taking place 24 hours after the operation. The longest course of treatment was 3 weeks. The control group was not irradiated. At 3 days, 1, 2, 3, and 5 weeks after surgery, 8 hens were sacrificed and their tendons were examined. The experimental results: (1) active, passive flexion and tendon gliding functional recovery were significantly better in the treatment group (p < 0.01); (2) width and thickness of the tendon at the cut site were significantly smaller in the treatment group (p < 0.01); (3) degrees of tendon adhesions were significantly lighter in the treatment group (p < 0.05). The experimental results demonstrate helium-neon laser radiation had significant effects on anti-inflammation, detumescence, progressive hematoma absorbing, inhibiting the tendon extrinsic healing, reducing tendon adhesions, improving the tendon intrinsic healing, i.e., stimulating epitenon and endotenon cells proliferation and migrating into the gap, stimulating collagen synthesis in the tendon gap, and enhancing the late remodeling of fibrous peritendonous adhesion.

  15. Management of acute Achilles tendon rupture with tendon-bundle technique

    PubMed Central

    Li, Chun-Guang; Li, Bing

    2017-01-01

    Objective *These authors contributed equally to this work.To explore tendon-bundle technique for treating Achilles tendon rupture with no defects. Methods Patients with full unilateral Achilles tendon rupture with no defects were included. The Achilles tendon medial edge surgical repair approach was used, revealing horsetail-like rupture bundles. Tendon bundles were anatomically realigned and repaired end-to-end using 5-0 sutures. Patients were followed-up for 1 year, and assessed for differences between the repaired versus healthy limb. Results Out of 24 patients (18 male, 6 female; aged 19–56 years) at 1 year following surgery, mean American Orthopaedic Foot and Ankle Society score was 92.4 ± 5.9; mean differences between the surgically repaired versus contralateral side in dorsiflexion and plantarflexion angle were 3.5 ± 2.3° and 5.6 ± 3.2°, respectively; mean difference in calf circumference between the two sides was 0.9 ± 0.5 cm; and mean increase in Achilles tendon width versus the healthy side was 0.8 ± 0.2 cm. By 1 year post-surgery, there were no significant between-side differences in dorsiflexion and plantarflexion angle, or calf circumference. Conclusions Tendon-bundle surgery resulted in good ankle function restoration and low complication rates. Tendon-bundle surgery may reduce blood supply destruction and maximally preserve Achilles tendon length, and may be effective for treating Achilles tendon rupture with no defects. PMID:28222622

  16. Proteomic Analysis Reveals Age-related Changes in Tendon Matrix Composition, with Age- and Injury-specific Matrix Fragmentation*

    PubMed Central

    Peffers, Mandy J.; Thorpe, Chavaunne T.; Collins, John A.; Eong, Robin; Wei, Timothy K. J.; Screen, Hazel R. C.; Clegg, Peter D.

    2014-01-01

    Energy storing tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), are highly prone to injury, the incidence of which increases with aging. The cellular and molecular mechanisms that result in increased injury in aged tendons are not well established but are thought to result in altered matrix turnover. However, little attempt has been made to fully characterize the tendon proteome nor determine how the abundance of specific tendon proteins changes with aging and/or injury. The aim of this study was, therefore, to assess the protein profile of normal SDFTs from young and old horses using label-free relative quantification to identify differentially abundant proteins and peptide fragments between age groups. The protein profile of injured SDFTs from young and old horses was also assessed. The results demonstrate distinct proteomic profiles in young and old tendon, with alterations in the levels of proteins involved in matrix organization and regulation of cell tension. Furthermore, we identified several new peptide fragments (neopeptides) present in aged tendons, suggesting that there are age-specific cleavage patterns within the SDFT. Proteomic profile also differed between young and old injured tendon, with a greater number of neopeptides identified in young injured tendon. This study has increased the knowledge of molecular events associated with tendon aging and injury, suggesting that maintenance and repair of tendon tissue may be reduced in aged individuals and may help to explain why the risk of injury increases with aging. PMID:25077967

  17. Biological intervertebral disc replacement: an in vivo model and comparison of two surgical techniques to approach the rat caudal disc

    PubMed Central

    Gebhard, Harry; James, Andrew R.; Bowles, Robby D.; Dyke, Jonathan P.; Saleh, Tatianna; Doty, Stephen P.; Bonassar, Lawrence J.; Härtl, Roger

    2011-01-01

    Study design: Prospective randomized animal study. Objective: To determine a surgical technique for reproducible and functional intervertebral disc replacement in an orthotopic animal model. Methods: The caudal 3/4 intervertebral disc (IVD) of the rat tail was approached by two surgical techniques: blunt dissection, stripping and retracting (Technique 1) or incising and repairing (Technique 2) the dorsal longitudinal tendons. The intervertebral disc was dissected and removed, and then either discarded or reinserted. Outcome measures were perioperative complications, spontaneous tail movement, 7T MRI (T1- and T2-sequences for measurement of disc space height (DSH) and disc hydration). Microcomputed tomographic imaging (micro CT) was additionally performed postmortem. Results: No vascular injuries occurred and no systemic or local infections were observed over the course of 1 month. Tail movements were maintained. With tendon retraction (Technique 1) gross loss of DSH occurred with both discectomy and reinsertion. Tendon division (Technique 2) maintained DSH with IVD reinsertion but not without. The DSH was demonstrated on MRI measurement. A new scoring system to assess IVD appearances was described. Conclusions: The rat tail model, with a tendon dividing surgical technique, can function as an orthotopic animal model for IVD research. Mechanical stimulation is maintained by preserved tail movements. 7T MRI is a feasible modality for longitudinal monitoring for the rat caudal disc. PMID:22956934

  18. Surgical versus conservative treatment following acute rupture of the Achilles tendon: is there a pedobarographic difference?

    PubMed

    Karaaslan, Fatih; Mermerkaya, Musa Uğur; Çıraklı, Alper; Karaoğlu, Sinan; Duygulu, Fuat

    2016-01-01

    Controversy remains regarding the optimal treatment method and postoperative rehabilitation of acute Achilles tendon ruptures. In this study, pedobarographic assessments of surgical and conservative treatments were compared. A prospective assessment was made of 16 patients (eight surgical, eight conservative) and eight healthy controls using a plantar pressure measurement system. Biomechanical gait parameters were obtained using the Footscan dynamic gait analysis system. Kruskal-Wallis and Mann-Whitney U-tests were used for the evaluation of data. Nineteen males and five females were assessed, with an average age of 42.0±11.9 years. Follow-up was completed in 16 patients. No statistically significant difference was determined between the two treatment groups with regard to the gait analysis, but a difference was observed with the control group (P<0.001). All patients were able to resume their prior activities after 6 months and regained normal ranges of motion, with a high rate of satisfaction. Most of the patients (75%) were able to return to their pre-injury level of activities. Satisfactory results were obtained through conservative treatment of acute ruptures of the Achilles tendon. No significant differences or complications were observed in the group managed conservatively versus the group treated surgically. Further studies including 3D gait analyses and tendon biomechanical research are required to further investigate this issue.

  19. Fibrocartilage associated with human tendons and their pulleys.

    PubMed Central

    Benjamin, M; Qin, S; Ralphs, J R

    1995-01-01

    The presence of fibrocartilage in tendons that wrap around bony or fibrous pulleys is well known. It is an adaptation to resisting compression or shear, but the extent to which the structure of most human tendons is modified where they contact pulleys is less clear, for there has been no single comprehensive survey of a large number of sites. Less is known of the structure of the corresponding pulleys. In the present study, 38 regions of tendons that wrap around bony pulleys or pass beneath fibrous retinacula have been studied in routine histology sections taken from each of 2 or 3 elderly dissecting room cadavers. Most of the corresponding pulleys have also been examined. Fibrocartilage was present in 22 of the 38 tendon sites and it was most conspicuous where the tendons pressed predominantly against bone rather than retinacula and where they showed a large change in direction. Fibrocartilage was more characteristic of tendons at the ankle than the wrist, probably because the long axis of the foot is at right angles to that of the leg. There was considerable variation in the structure of tendon fibrocartilage. The most fibrocartilaginous tendons had oval or round cells embedded in a highly metachromatic matrix with interwoven or spiralling collagen fibres. At other sites, fibrocartilage cells were arranged in rows between parallel collagen fibres. The differences probably relate to differences in development. A single tendon could be modified at successive points along its length and fibrocartilage could be present in the endotenon and epitenon as well as in the tendon itself. Pathological changes seen in 'wrap around' tendons were fragmentation and partial delamination of the compressed surface, chondrocyte clustering, fatty infiltration and bone formation. Three types of pulleys were described for tendons--bony prominences and grooves, fibrous retinacula and synovial joints. The extent of cartilaginous differentiation on the periosteum of bony pulleys frequently mirrored that in the corresponding tendon. The cartilage or fibrocartilage prevents the tendon from 'sawing' through the bone. Some of the best known retinacula were largely fibrous, though the inferior peroneal retinaculum and the trochlea for the superior oblique were cartilaginous. The results underline the considerable regional heterogeneity in different tendons and their pulleys. They show that one tendon is not like another and that tendons may need to be carefully selected for particular surgical transfers or joint reconstructions. Images Fig. 1 Figs 2-3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 PMID:8586561

  20. Tendon elasticity and muscle function.

    PubMed

    Alexander, R McNeill

    2002-12-01

    Vertebrate animals exploit the elastic properties of their tendons in several different ways. Firstly, metabolic energy can be saved in locomotion if tendons stretch and then recoil, storing and returning elastic strain energy, as the animal loses and regains kinetic energy. Leg tendons save energy in this way when birds and mammals run, and an aponeurosis in the back is also important in galloping mammals. Tendons may have similar energy-saving roles in other modes of locomotion, for example in cetacean swimming. Secondly, tendons can recoil elastically much faster than muscles can shorten, enabling animals to jump further than they otherwise could. Thirdly, tendon elasticity affects the control of muscles, enhancing force control at the expense of position control.

  1. The Achilles tendon: fundamental properties and mechanisms governing healing

    PubMed Central

    Freedman, Benjamin R.; Gordon, Joshua A.; Soslowsky, Louis J.

    2014-01-01

    Summary This review highlights recent research on Achilles tendon healing, and comments on the current clinical controversy surrounding the diagnosis and treatment of injury. The processes of Achilles tendon healing, as demonstrated through changes in its structure, composition, and biomechanics, are reviewed. Finally, a review of tendon developmental biology and mechano transductive pathways is completed to recognize recent efforts to augment injured Achilles tendons, and to suggest potential future strategies for therapeutic intervention and functional tissue engineering. Despite an abundance of clinical evidence suggesting that current treatments and rehabilitation strategies for Achilles tendon ruptures are equivocal, significant questions remain to fully elucidate the basic science mechanisms governing Achilles tendon injury, healing, treatment, and rehabilitation. PMID:25332943

  2. The role of ultrasound in the management of flexor tendon injuries.

    PubMed

    Jeyapalan, K; Bisson, M A; Dias, J J; Griffin, Y; Bhatt, R

    2008-08-01

    The use of ultrasound scanning to establish tendon pathologies was assessed retrospectively in 17 patients in 18 digits. The ultrasound scan demonstrated four patterns: (1) normal intact tendons in four, (2) ruptured tendons in three, (3) tendons in continuity but attenuated in five and (4) tendons in continuity but thickened with fibrosis and decreased movement representing adhesions in five patients. Surgery was undertaken in only three cases, confirming the ultrasound diagnosis in two. Surgery was offered to all three patients with ruptures but was declined by two. Ultrasound imaging helped to avoid surgery in 14 cases by excluding flexor tendon re-ruptures. This allowed on-going mobilisation, leading to recovery of function.

  3. Distal Biceps Tendon Rupture

    DTIC Science & Technology

    2010-06-01

    Distal Biceps Tendon Rupture Military Medicine Radiology Corner, 2006 Radiology Corner Distal Biceps Tendon Rupture Contributors: CPT Michael...treatment of a 56-year-old man with complete rupture of the distal biceps tendon . The mechanism of injury, symptoms, and findings at physical...be used in pre-operative planning. Introduction Rupture of the distal biceps tendon is a relatively uncommon injury, but delayed diagnosis may

  4. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    PubMed Central

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. Results: The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º (P = .75) or 90º (P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference (P = .28). Conclusion: Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. Clinical Relevance: This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures. PMID:28607942

  5. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    PubMed

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  6. Human Leg Model Predicts Muscle Forces, States, and Energetics during Walking.

    PubMed

    Markowitz, Jared; Herr, Hugh

    2016-05-01

    Humans employ a high degree of redundancy in joint actuation, with different combinations of muscle and tendon action providing the same net joint torque. Both the resolution of these redundancies and the energetics of such systems depend on the dynamic properties of muscles and tendons, particularly their force-length relations. Current walking models that use stock parameters when simulating muscle-tendon dynamics tend to significantly overestimate metabolic consumption, perhaps because they do not adequately consider the role of elasticity. As an alternative, we posit that the muscle-tendon morphology of the human leg has evolved to maximize the metabolic efficiency of walking at self-selected speed. We use a data-driven approach to evaluate this hypothesis, utilizing kinematic, kinetic, electromyographic (EMG), and metabolic data taken from five participants walking at self-selected speed. The kinematic and kinetic data are used to estimate muscle-tendon lengths, muscle moment arms, and joint moments while the EMG data are used to estimate muscle activations. For each subject we perform an optimization using prescribed skeletal kinematics, varying the parameters that govern the force-length curve of each tendon as well as the strength and optimal fiber length of each muscle while seeking to simultaneously minimize metabolic cost and maximize agreement with the estimated joint moments. We find that the metabolic cost of transport (MCOT) values of our participants may be correctly matched (on average 0.36±0.02 predicted, 0.35±0.02 measured) with acceptable joint torque fidelity through application of a single constraint to the muscle metabolic budget. The associated optimal muscle-tendon parameter sets allow us to estimate the forces and states of individual muscles, resolving redundancies in joint actuation and lending insight into the potential roles and control objectives of the muscles of the leg throughout the gait cycle.

  7. A Multi-modality Approach Towards Elucidation of the Mechanism for Human Achilles Tendon Bending During Passive Ankle Rotation.

    PubMed

    Kinugasa, Ryuta; Taniguchi, Keigo; Yamamura, Naoto; Fujimiya, Mineko; Katayose, Masaki; Takagi, Shu; Edgerton, V Reggie; Sinha, Shantanu

    2018-03-12

    The in vitro unconstrained Achilles tendon is nearly straight, while in vivo experiments reveal that the proximal region of the Achilles tendon, adjacent to Kager's fat pad, bends ventrally during plantarflexion but remains nearly straight during dorsiflexion. Tendon bending is an important factor in determining the displacement of the foot compared to the shortening of the muscle fibers. The objective of this study was to elucidate the various mechanisms that could cause tendon bending, which currently remain unknown. Examination of Thiel-embalmed cadavers, with preservation of native articular joint mobility, revealed that the Achilles tendon still bent ventrally even when its surrounding tissues, including the skin surface, Kager's fat pad, and distal portions of the soleus muscle were removed. Shear modulus and collagen fiber orientation were distributed homogeneously with respect to the longitudinal line of the tendon, minimizing their causative contributions to the bending. Given that tendon bending is not caused by either the nature of the deformations of the tissues surrounding the Achilles tendon or its physical properties, we conclude that it results from the geometric architecture of the Achilles tendon and its configuration with respect to the surrounding tissues.

  8. Effects of habitual loading on patellar tendon mechanical and morphological properties in basketball and volleyball players.

    PubMed

    Zhang, Z J; Ng, G Y F; Fu, S N

    2015-11-01

    Tendon mechanical properties are linked to sports performance and tendon-related injuries, such as tendinopathy. Whether habitual loading, such as participation in regular jumping activities, would induce adaptation on tendon mechanical properties remains unclear. Forty healthy subjects (10 sedentary, 15 volleyball players, and 15 basketball players) aged between 18 and 35 years were recruited. Supersonic shearwave imaging was used to measure the shear elastic modulus and thickness and cross-sectional area (CSA) of the proximal patellar tendons of both knees at 30° of flexion. Significant group differences in tendon shear elastic modulus were found among the three groups. In the dominant leg, reduction in tendon shear elastic modulus by 18.9 % (p = 0.018) and 48.7 % (p = 0.000) were observed in the basketball and volleyball players, respectively, when compared with sedentary subjects. In the non-dominant leg, reduction in tendon shear elastic modulus were 27.3 % (p = 0.034) and 47.1 % (p = 0.02) in the basketball and volleyball players, respectively. The athlete groups were found to have larger CSA but with similar tendon thickness than sedentary group. The CSA were larger by 24-29 % and by 22-24 % in the basketball players and volleyball players, for the dominant and non-dominant legs, respectively (all p < 0.05). Age and body mass are related to tendon stiffness and CSA, particularly in the sedentary subjects. The proximal patellar tendon can undergo substantial adaptation on tendon mechanical and morphological properties when exposed in jumping sports. Intrinsic factors such as age and body mass could influence tendon properties.

  9. Rupture Following Biceps-to-Triceps Tendon Transfer in Adolescents and Young Adults With Spinal Cord Injury:

    PubMed Central

    Merenda, Lisa A.; Rutter, Laure; Curran, Kimberly; Kozin, Scott H.

    2012-01-01

    Background: Tendon transfer surgery can restore elbow extension in approximately 70% of persons with tetraplegia and often results in antigravity elbow extension strength. However, we have noted an almost 15% rupture/attenuation rate. Objective: This investigation was conducted to analyze potential causes in adolescents/young adults with spinal cord injury (SCI) who experienced tendon rupture or attenuation after biceps-to-triceps transfer. Methods: Medical charts of young adults with SCI who underwent biceps-to-triceps transfer and experienced tendon rupture or attenuation were reviewed. Data collected by retrospective chart review included general demographics, surgical procedure(s), use and duration of antibiotic treatment, time from tendon transfer surgery to rupture/attenuation, and method of diagnosis. Results: Twelve subjects with tetraplegia (mean age, 19 years) who underwent biceps-to-triceps reconstruction with subsequent tendon rupture or attenuation were evaluated. Mean age at time of tendon transfer was 18 years (range, 14-21 years). A fluoroquinolone was prescribed for 42% (n=5) of subjects. Tendon rupture was noted in 67% (n=8), and attenuation was noted in 33% (n=4). Average length of time from surgery to tendon rupture/attenuation was 5.7 months (range, 3-10 months). Conclusion: Potential contributing causes of tendon rupture/attenuation after transfer include surgical technique, rehabilitation, co-contraction of the transfer, poor patient compliance, and medications. In this cohort, 5 subjects were prescribed fluoroquinolones that have a US Food and Drug Administration black box concerning tendon ruptures. Currently, all candidates for upper extremity tendon transfer reconstruction are counseled on the effects of fluoroquinolones and the potential risk for tendon rupture. PMID:23459326

  10. The Influence of External Load on Quadriceps Muscle and Tendon Dynamics during Jumping.

    PubMed

    Earp, Jacob E; Newton, Robert U; Cormie, Prue; Blazevich, Anthony J

    2017-11-01

    Tendons possess both viscous (rate-dependent) and elastic (rate-independent) properties that determine tendon function. During high-speed movements external loading increases both the magnitude (FT) and rate (RFDT) of tendon loading. The influence of external loading on muscle and tendon dynamics during maximal vertical jumping was explored. Ten resistance-trained men performed parallel-depth, countermovement vertical jumps with and without additional load (0%, 30%, 60%, and 90% of maximum squat lift strength), while joint kinetics and kinematics, quadriceps tendon length (LT) and patellar tendon FT and RFDT were estimated using integrated ultrasound, motion analysis and force platform data and muscle tendon modelling. Estimated FT and RFDT, but not peak LT, increased with external loading. Temporal comparisons between 0% and 90% loads revealed that FT was greater with 90% loading throughout the majority of the movement (11%-81% and 87%-95% movement duration). However, RFDT was greater with 90% load only during the early movement initiation phase (8%-15% movement duration) but was greater in the 0% load condition later in the eccentric phase (27%-38% movement duration). LT was longer during the early movement (12%-23% movement duration) but shorter in the late eccentric and early concentric phases (48%-55% movement duration) with 90% load. External loading positively influenced peak FT and RFDT but tendon strain appeared unaffected, suggesting no additive effect of external loading on patellar tendon lengthening during human jumping. Temporal analysis revealed that external loading resulted in a large initial RFDT that may have caused dynamic stiffening of the tendon and attenuated tendon strain throughout the movement. These results suggest that external loading influences tendon lengthening in both a load- and movement-dependent manner.

  11. Visualization of the extra-articular portion of the long head of the biceps tendon during intra-articular shoulder arthroscopy.

    PubMed

    Festa, Anthony; Allert, Jesse; Issa, Kimona; Tasto, James P; Myer, Jonathan J

    2014-11-01

    To quantify the amount of the extra-articular long head of the biceps tendon (LHBT) seen during intra-articular shoulder arthroscopy by pulling the tendon into the joint with a probe through an anterior portal while viewing through a standard posterior portal. Intra-articular shoulder arthroscopy was performed on 10 forequarter cadaveric specimens. The extra-articular portion of the LHBT was evaluated by pulling the tendon into the joint with an arthroscopic probe inserted through an anterior portal. The tendon was marked at the pulley insertion on the humerus with a vascular clip before and after the tendon was pulled into the joint. An open deltopectoral approach was performed, and the amount of extra-articular tendon visualized was calculated as an absolute amount and in relation to nearby anatomic structures. An additional 1.9 cm (range, 1.4 to 2.6 cm) of extra-articular LHBT was viewed by pulling the tendon into the joint with an arthroscopic probe through an anterior portal during shoulder arthroscopy. This represented 30.8% of the extra-articular portion of the tendon, 47.7% of tendon in the bicipital groove, and 76.3% of the tendon that lies under the area from the pulley insertion to the distal edge of the transverse humeral ligament. During intra-articular shoulder arthroscopy, the extra-articular portion of the LHBT is incompletely visualized by pulling the tendon into the joint with a probe placed through an anterior portal while viewing through a standard posterior portal. An additional extra-articular portion of the LHBT may be viewed by pulling the tendon into the joint with an arthroscopic probe during shoulder arthroscopy. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Decorin and biglycan are necessary for maintaining collagen fibril structure, fiber realignment, and mechanical properties of mature tendons.

    PubMed

    Robinson, Kelsey A; Sun, Mei; Barnum, Carrie E; Weiss, Stephanie N; Huegel, Julianne; Shetye, Snehal S; Lin, Linda; Saez, Daniel; Adams, Sheila M; Iozzo, Renato V; Soslowsky, Louis J; Birk, David E

    2017-12-01

    The small leucine-rich proteoglycans (SLRPs), decorin and biglycan, are key regulators of collagen fibril and matrix assembly. The goal of this work was to elucidate the roles of decorin and biglycan in tendon homeostasis. Our central hypothesis is that decorin and biglycan expression in the mature tendon would be critical for the maintenance of the structural and mechanical properties of healthy tendons. Defining the function(s) of these SLRPs in tendon homeostasis requires that effects in the mature tendon be isolated from their influence on development. Thus, we generated an inducible knockout mouse model that permits genetic ablation of decorin and biglycan expression in the mature tendon, while maintaining normal expression during development. Decorin and biglycan expression were knocked out in the mature patellar tendon with the subsequent turnover of endogenous SLRPs deposited prior to induction. The acute absence of SLRP expression was associated with changes in fibril structure with a general shift to larger diameter fibrils in the compound knockout tendons, together with fibril diameter heterogeneity. In addition, tendon mechanical properties were altered. Compared to wild-type controls, acute ablation of both genes resulted in failure of the tendon at lower loads, decreased stiffness, a trend towards decreased dynamic modulus, as well as a significant increase in percent relaxation and tissue viscosity. Collagen fiber realignment was also increased with a delayed and slower in response to load in the absence of expression. These structural and functional changes in response to an acute loss of decorin and biglycan expression in the mature tendon demonstrate a significant role for these SLRPs in adult tendon homeostasis. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. The role of three-dimensional pure bovine gelatin scaffolds in tendon healing, modeling, and remodeling: an in vivo investigation with potential clinical value.

    PubMed

    Oryan, Ahmad; Sharifi, Pardis; Moshiri, Ali; Silver, Ian A

    2017-09-01

    Large tendon defects involving extensive tissue loss present complex clinical problems. Surgical reconstruction of such injuries is normally performed by transplanting autogenous and allogenous soft tissues that are expected to remodel to mimic a normal tendon. However, the use of grafts has always been associated with significant limitations. Tissue engineering employing artificial scaffolds may provide acceptable alternatives. Gelatin is a hydrolyzed form of collagen that is bioactive, biodegradable, and biocompatible. The present study has investigated the suitability of gelatin scaffold for promoting healing of a large tendon-defect model in rabbits. An experimental model of a large tendon defect was produced by partial excision of the Achilles tendon of the left hind leg in adult rabbits. To standardize and stabilize the length of the tendon defect a modified Kessler core suture was anchored in the sectioned tendon ends. The defects were either left untreated or filled with three-dimensional gelatin scaffold. Before euthanasia 60 days after injury, the progress of healing was evaluated clinically. Samples of healing tendon were harvested at autopsy and evaluated by gross, histopathologic, scanning, and transmission electron microscopy, and by biomechanical testing. The treated animals showed superior weight-bearing and physical activity compared with those untreated, while frequency of peritendinous adhesions around the healing site was reduced. The gelatin scaffold itself was totally degraded and replaced by neo-tendon that morphologically had significantly greater numbers, diameters, density, and maturation of collagen fibrils, fibers, and fiber bundles than untreated tendon scar tissue. It also had mechanically higher ultimate load, yield load, stiffness, maximum stress and elastic modulus, when compared to the untreated tendons. Gelatin scaffold may be a valuable option in surgical reconstruction of large tendon defects.

  14. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  15. Platelet-rich plasma in tendon-related disorders: results and indications.

    PubMed

    Filardo, Giuseppe; Di Matteo, Berardo; Kon, Elizaveta; Merli, Giulia; Marcacci, Maurilio

    2016-09-24

    Platelet-rich plasma (PRP) is currently the most exploited strategy in the clinical practice to provide a regenerative stimulus for tendon healing. The aim of the present study was to systematically review the available evidence on the treatment of the main tendon disorders where PRP is currently applied. A systematic review of the literature was performed on the use of PRP as a treatment for tendinopathies focusing on the following sites: Achilles tendon, patellar tendon, rotator cuff tendons, and lateral elbow tendons. The following inclusion criteria for relevant articles were used: clinical trials written in English language up to 21 June 2016 on the use of PRP in the conservative or surgical treatment of the aforementioned tendinopathies. The research identified the following clinical trials dealing with the application of PRP in the selected tendons: 19 papers on patellar tendon (6 being RCTs: 4 dealing with PRP conservative application and 2 surgical), 24 papers on Achilles tendon (4 RCTs: 3 conservative and 1 surgical), 29 on lateral elbow tendons (17 RCTs, all conservative), and 32 on rotator cuff (22 RCTs: 18 surgical and 3 conservative). Patellar tendons seem to benefit from PRP injections, whereas in the Achilles tendon, PRP application is not indicated neither as a conservative approach nor as a surgical augmentation. Lateral elbow tendinopathy showed an improvement in most of the high-level studies, but the lack of proven superiority with respect to the more simple whole-blood injections still questions its use in the clinical practice. With regard to rotator cuff pathology, the vast majority of surgical RCTs documented a lack of beneficial effects, whereas there is still inconclusive evidence concerning its conservative application in rotator cuff disorders. Systematic review of level I-IV trials, Level IV.

  16. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  17. Biochemical, histologic, and biomechanical characterization of native and decellularized flexor tendon specimens harvested from the pelvic limbs of orthopedically normal dogs.

    PubMed

    Balogh, Daniel G; Biskup, Jeffery J; O'Sullivan, M Gerard; Scott, Ruth M; Groschen, Donna; Evans, Richard B; Conzemius, Michael G

    2016-04-01

    To evaluate the biochemical and biomechanical properties of native and decellularized superficial digital flexor tendons (SDFTs) and deep digital flexor tendons (DDFTs) harvested from the pelvic limbs of orthopedically normal dogs. 22 commercially supplied tendon specimens (10 SDFT and 12 DDFT) harvested from the pelvic limbs of 13 canine cadavers. DNA, glycosaminoglycan, collagen, and protein content were measured to biochemically compare native and decellularized SDFT and DDFT specimens. Mechanical testing was performed on 4 groups consisting of native tendons (5 SDFTs and 6 DDFTs) and decellularized tendons (5 SDFTs and 6 DDFTs). All tendons were preconditioned, and tension was applied to failure at 0.5 mm/s. Failure mode was video recorded for each tendon. Load-deformation and stress-strain curves were generated; calculations were performed to determine the Young modulus and stiffness. Biochemical and biomechanical data were statistically compared by use of the Wilcoxon rank sum test. Decellularized SDFT and DDFT specimens had significantly less DNA content than did native tendons. No significant differences were identified between native and decellularized specimens with respect to glycosaminoglycan, collagen, or protein content. Biomechanical comparison yielded no significant intra- or intergroup differences. All DDFT constructs failed at the tendon-clamp interface, whereas nearly half (4/10) of the SDFT constructs failed at midsubstance. Decellularized commercial canine SDFT and DDFT specimens had similar biomechanical properties, compared with each other and with native tendons. The decellularization process significantly decreased DNA content while minimizing loss of extracellular matrix components. Decellularized canine flexor tendons may provide suitable, biocompatible graft scaffolds for bioengineering applications such as tendon or ligament repair.

  18. A new laser reflectance system capable of measuring changing cross-sectional area of soft tissues during tensile testing.

    PubMed

    Pokhai, Gabriel G; Oliver, Michele L; Gordon, Karen D

    2009-09-01

    Determination of the biomechanical properties of soft tissues such as tendons and ligaments is dependent on the accurate measurement of their cross-sectional area (CSA). Measurement methods, which involve contact with the specimen, are problematic because soft tissues are easily deformed. Noncontact measurement methods are preferable in this regard, but may experience difficulty in dealing with the complex cross-sectional shapes and glistening surfaces seen in soft tissues. Additionally, existing CSA measurement systems are separated from the materials testing machine, resulting in the inability to measure CSA during testing. Furthermore, CSA measurements are usually made in a different orientation, and with a different preload, prior to testing. To overcome these problems, a noncontact laser reflectance system (LRS) was developed. Designed to fit in an Instron 8872 servohydraulic test machine, the system measures CSA by orbiting a laser transducer in a circular path around a soft tissue specimen held by tissue clamps. CSA measurements can be conducted before and during tensile testing. The system was validated using machined metallic specimens of various shapes and sizes, as well as different sizes of bovine tendons. The metallic specimens could be measured to within 4% accuracy, and the tendons to within an average error of 4.3%. Statistical analyses showed no significant differences between the measurements of the LRS and those of the casting method, an established measurement technique. The LRS was successfully used to measure the changing CSA of bovine tendons during uniaxial tensile testing. The LRS developed in this work represents a simple, quick, and accurate way of reconstructing complex cross-sectional profiles and calculating cross-sectional areas. In addition, the LRS represents the first system capable of automatically measuring changing CSA of soft tissues during tensile testing, facilitating the calculation of more accurate biomechanical properties.

  19. Anatomy of the Adductor Magnus Origin

    PubMed Central

    Obey, Mitchel R.; Broski, Stephen M.; Spinner, Robert J.; Collins, Mark S.; Krych, Aaron J.

    2016-01-01

    Background: The adductor magnus (AM) has historically been a potential source of confusion in patients with suspected proximal hamstring avulsion injuries. Purpose: To investigate the anatomic characteristics of the AM, including its osseous origin, anatomic dimensions, and relationship to the proximal hamstring tendons. Study Design: Descriptive laboratory study. Methods: Dissection of the AM origin was performed in 11 (8 cadavers) fresh-frozen hip-to-foot cadaveric hemipelvis specimens. The gross anatomy and architecture of the proximal hamstring and AM tendons were studied. After dissecting the hamstring tendons away from their origin, the dimension, shape, and orientation of the tendon footprints on the ischial tuberosity were determined. Results: The AM was identified in all cadaveric specimens. The mean tendon thickness (anterior to posterior [AP]) was 5.7 ± 2.9 mm. The mean tendon width (medial to lateral [ML]) was 7.1 ± 2.2 mm. The mean tendon length was 13.1 ± 8.7 cm. The mean footprint height (AP dimension) was 12.1 ± 2.9 mm, and mean footprint width (ML dimension) was 17.3 ± 7.1 mm. The mean distance between the AM footprint and the most medial aspect of the conjoint tendon footprint was 8.5 ± 4.2 mm. Tendon measurements demonstrated a considerable degree of both intra- and interspecimen variability. Conclusion: The AM tendon is consistently present just medial to the conjoint tendon at the ischial tuberosity, representing the lateral-most portion of the AM muscle. This study found wide variation in the dimensional characteristics of the AM tendon between specimens. Its shape and location can mimic the appearance of an intact hamstring (conjoint or semimembranosus) tendon intraoperatively or on diagnostic imaging, potentially misleading surgeons and radiologists. Therefore, detailed knowledge of the AM tendon anatomy, footprint anatomy, and its relationship to the hamstring muscle complex is paramount when planning surgical approach and technique. Clinical Relevance: The reported data may aid surgeons in more accurate recognition, diagnosis, and repair of proximal hamstring avulsion injuries. PMID:26798764

  20. [A comparative study on repair of acute Achilles tendon rupture using three operating techniques].

    PubMed

    Wang, Ting; Mei, Guohua; Shi, Zhongmin; Chai, Yimin; Zhang, Changqing; Hou, Chunlin

    2012-07-01

    To compare the effectiveness of the 3 methods (traditional open Achilles tendon anastomosis, minimally invasive percutaneous Achilles tendon anastomosis, and Achilles tendon anastomosis limited incision) for acute Achilles tendon rupture so as to provide a reference for the choice of clinical treatment plans. Between December 2007 and March 2010, 69 cases of acute Achilles tendon rupture were treated by traditional open Achilles tendon anastomosis (traditional group, n=23), by minimally invasive percutaneous Achilles tendon anastomosis (minimally invasive group, n=23), and by Achilles tendon anastomosis limited incision (limited incision group, n=23). There was no significant difference in gender, age, mechanism of injury, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score between 3 groups (P > 0.05). Minimally invasive group and limited incision group were significantly better than traditional group in hospitalization days and blood loss (P < 0.01). Incision infection occurred in 2 cases of traditional group, and healing of incision by first intention was achieved in all patients of the other 2 groups, showing significant difference in the complication rate (P < 0.05). Re-rupture of Achilles tendon occurred in 1 case (4.3%) of minimally invasive group and limited incision group respectively; no re-rupture was found in traditional group (0), showing significant difference when compared with the other 2 groups (P < 0.05). All cases were followed up 12-18 months with an average of 14.9 months. The function of the joint was restored. The AOFAS score was more than 90 points in 3 groups at 12 months after operation, showing no significant difference among 3 groups (P > 0.05). The above 3 procedures can be used to treat acute Achilles tendon rupture. However, minimally invasive percutaneous Achilles tendon anastomosis and Achilles tendon anastomosis limited incision have the advantages of less invasion, good healing, short hospitalization days, and less postoperative complication, and have the disadvantage of increased risk for re-rupture of Achilles tendon after operations.

  1. Accumulation of oxidized LDL in the tendon tissues of C57BL/6 or apolipoprotein E knock-out mice that consume a high fat diet: potential impact on tendon health.

    PubMed

    Grewal, Navdeep; Thornton, Gail M; Behzad, Hayedeh; Sharma, Aishwariya; Lu, Alex; Zhang, Peng; Reid, W Darlene; Granville Alex Scott, David J

    2014-01-01

    Clinical studies have suggested an association between dyslipidemia and tendon injuries or chronic tendon pain; the mechanisms underlying this association are not yet known. The objectives of this study were (1) to evaluate the impact of a high fat diet on the function of load-bearing tendons and on the distribution in tendons of oxidized low density lipoprotein (oxLDL), and (2) to examine the effect of oxLDL on tendon fibroblast proliferation and gene expression. Gene expression (Mmp2, Tgfb1, Col1a1, Col3a1), fat content (Oil Red O staining), oxLDL levels (immunohistochemistry) and tendon biomechanical properties were examined in mice (C57Bl/6 or ApoE -/-) receiving a standard or a high fat diet. Human tendon fibroblast proliferation and gene expression (COL1A1, COL3A1, MMP2) were examined following oxLDL exposure. In both types of mice (C57Bl/6 or ApoE -/-), consumption of a high fat diet led to a marked increase in oxLDL deposition in the load-bearing extracellular matrix of the tendon. The consumption of a high fat diet also reduced the failure stress and load of the patellar tendon in both mouse types, and increased Mmp2 expression. ApoE -/- mice exhibited more pronounced reductions in tendon function than wild-type mice, and decreased expression of Col1a1 compared to wild type mice. Human tendon fibroblasts responded to oxLDL by increasing their proliferation and their mRNA levels of MMP2, while decreasing their mRNA levels for COL1A1 and COL3A1. The consumption of a high fat diet resulted in deleterious changes in tendon function, and these changes may be explained in part by the effects of oxLDL, which induced a proliferative, matrix-degrading phenotype in human tenocytes.

  2. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    PubMed

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This implant may be a valuable option in clinical practice. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. A Fibre-Reinforced Poroviscoelastic Model Accurately Describes the Biomechanical Behaviour of the Rat Achilles Tendon

    PubMed Central

    Heuijerjans, Ashley; Matikainen, Marko K.; Julkunen, Petro; Eliasson, Pernilla; Aspenberg, Per; Isaksson, Hanna

    2015-01-01

    Background Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon’s biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally. Materials and Methods We developed a new material model of the Achilles tendon, which considers the tendon’s main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output. Results and Conclusions All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendon’s viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons. PMID:26030436

  4. Treatment of peroneal nerve injuries with simultaneous tendon transfer and nerve exploration.

    PubMed

    Ho, Bryant; Khan, Zubair; Switaj, Paul J; Ochenjele, George; Fuchs, Daniel; Dahl, William; Cederna, Paul; Kung, Theodore A; Kadakia, Anish R

    2014-08-06

    Common peroneal nerve palsy leading to foot drop is difficult to manage and has historically been treated with extended bracing with expectant waiting for return of nerve function. Peroneal nerve exploration has traditionally been avoided except in cases of known traumatic or iatrogenic injury, with tendon transfers being performed in a delayed fashion after exhausting conservative treatment. We present a new strategy for management of foot drop with nerve exploration and concomitant tendon transfer. We retrospectively reviewed a series of 12 patients with peroneal nerve palsies that were treated with tendon transfer from 2005 to 2011. Of these patients, seven were treated with simultaneous peroneal nerve exploration and repair at the time of tendon transfer. Patients with both nerve repair and tendon transfer had superior functional results with active dorsiflexion in all patients, compared to dorsiflexion in 40% of patients treated with tendon transfers alone. Additionally, 57% of patients treated with nerve repair and tendon transfer were able to achieve enough function to return to running, compared to 20% in patients with tendon transfer alone. No patient had full return of native motor function resulting in excessive dorsiflexion strength. The results of our limited case series for this rare condition indicate that simultaneous nerve repair and tendon transfer showed no detrimental results and may provide improved function over tendon transfer alone.

  5. Stretching Your Energetic Budget: How Tendon Compliance Affects the Metabolic Cost of Running

    PubMed Central

    Uchida, Thomas K.; Hicks, Jennifer L.; Dembia, Christopher L.; Delp, Scott L.

    2016-01-01

    Muscles attach to bones via tendons that stretch and recoil, affecting muscle force generation and metabolic energy consumption. In this study, we investigated the effect of tendon compliance on the metabolic cost of running using a full-body musculoskeletal model with a detailed model of muscle energetics. We performed muscle-driven simulations of running at 2–5 m/s with tendon force–strain curves that produced between 1 and 10% strain when the muscles were developing maximum isometric force. We computed the average metabolic power consumed by each muscle when running at each speed and with each tendon compliance. Average whole-body metabolic power consumption increased as running speed increased, regardless of tendon compliance, and was lowest at each speed when tendon strain reached 2–3% as muscles were developing maximum isometric force. When running at 2 m/s, the soleus muscle consumed less metabolic power at high tendon compliance because the strain of the tendon allowed the muscle fibers to operate nearly isometrically during stance. In contrast, the medial and lateral gastrocnemii consumed less metabolic power at low tendon compliance because less compliant tendons allowed the muscle fibers to operate closer to their optimal lengths during stance. The software and simulations used in this study are freely available at simtk.org and enable examination of muscle energetics with unprecedented detail. PMID:26930416

  6. Obesity/Type II diabetes alters macrophage polarization resulting in a fibrotic tendon healing response

    PubMed Central

    Ackerman, Jessica E.; Geary, Michael B.; Orner, Caitlin A.; Bawany, Fatima

    2017-01-01

    Type II Diabetes (T2DM) dramatically impairs the tendon healing response, resulting in decreased collagen organization and mechanics relative to non-diabetic tendons. Despite this burden, there remains a paucity of information regarding the mechanisms that govern impaired healing of diabetic tendons. Mice were placed on either a high fat diet (T2DM) or low fat diet (lean) and underwent flexor tendon transection and repair surgery. Healing was assessed via mechanical testing, histology and changes in gene expression associated with collagen synthesis, matrix remodeling, and macrophage polarization. Obese/diabetic tendons healed with increased scar formation and impaired mechanical properties. Consistent with this, prolonged and excess expression of extracellular matrix (ECM) components were observed in obese/T2DM tendons. Macrophages are involved in both inflammatory and matrix deposition processes during healing. Obese/T2DM tendons healed with increased expression of markers of pro-inflammatory M1 macrophages, and elevated and prolonged expression of M2 macrophages markers that are involved in ECM deposition. Here we demonstrate that tendons from obese/diabetic mice heal with increased scar formation and increased M2 polarization, identifying excess M2 macrophage activity and matrix synthesis as a potential mechanism of the fibrotic healing phenotype observed in T2DM tendons, and as such a potential target to improve tendon healing in T2DM. PMID:28686669

  7. Use of quantitative analysis of sonographic brightness for detection of early healing of tendon injury in horses.

    PubMed

    Micklethwaite, L; Wood, A K; Sehgal, C M; Polansky, M; Dowling, B A; Dart, A J; Rose, R J; Hodgson, D R

    2001-08-01

    To determine whether quantitative analysis of sonographic brightness could be used to detect healing of an induced injury of the superficial digital flexor tendon in horses and whether rate of healing was influenced by equine recombinant growth hormone. 8 clinically normal Standardbreds. A localized injury was created in the left and right superficial digital flexor tendons of each horse by injection of 2,000 units of collagenase. After injury, 4 horses received equine recombinant growth hormone, a possible promoter of tendon healing. Sonographic images (7.5 MHz) of the flexor tendons and ligaments of the metacarpal region were recorded on videotape prior to injury and weekly for 7 weeks after injury. Images were digitized, and sonographic brightness of tendons and ligaments was calculated. Collagenase-induced injury was sonographically similar to naturally occurring injury. After injury, sonographic brightness of the tendon decreased; after 3 weeks, brightness progressively increased, although by 7 weeks brightness had not returned to preinjury value. Equine recombinant growth hormone had no significant effect on the rate of tendon healing, as evaluated sonographically or at necropsy. As healing developed, alterations in sonographic brightness of injured tendons coincided with real changes in tendon structure. Quantitative sonographic brightness could be used to accurately monitor healing of equine tendon and ligament injuries and investigate the efficacy of various treatment regimens.

  8. [Secondary tendon reconstruction on the thumb].

    PubMed

    Bickert, B; Kremer, T; Kneser, U

    2016-12-01

    Closed tendon ruptures of the thumb that require secondary reconstruction can affect the extensor pollicis longus (EPL), extensor pollicis brevis (EPB) and flexor pollicis longus (FPL) tendons. Treatment of rupture of the EPB tendon consists of refixation to the bone and temporary transfixation of the joint. In the case of preexisting or posttraumatic arthrosis, definitive arthrodesis of the thumb is the best procedure. Closed ruptures of the EPL and FPL tendons at the wrist joint cannot be treated by direct tendon suture. Rupture of the EPL tendon occurs after distal radius fractures either due to protruding screws or following conservative treatment especially in undisplaced fractures. Transfer of the extensor indicis tendon to the distal EPL stump is a good option and free interposition of the palmaris longus tendon is a possible alternative. The tension should be adjusted to slight overcorrection, which can be checked intraoperatively by performing the tenodesis test. Closed FPL ruptures at the wrist typically occur 3-6 months after osteosynthesis of distal radius fractures with palmar plates and are mostly characterized by crepitation and pain lasting for several weeks. They can be prevented by premature plate removal, synovectomy and carpal tunnel release. For treatment of a ruptured FPL tendon in adult patients the options for tendon reconstruction should be weighed up against the less complicated tenodesis or arthrodesis of the thumb interphalangeal joint.

  9. Foot Health Facts for Athletes

    MedlinePlus

    ... more likely to suffer repeated sprains, leading to chronic ankle instability. Achilles tendon disorders —Athletes are at high risk for developing disorders of the Achilles tendon. Achilles tendonitis , an inflammation of the tendon that runs down the back ...

  10. Modified tendon stripper for obtaining palmaris longus tendon graft.

    PubMed

    Aköz, T; Altintaş, H; Civelek, B

    1999-04-01

    Tendon graft harvesting is a challenging part of hand surgery. It is not only a time-consuming procedure but also carries the potential complications associated with it. Various alternatives for this procedure are presented in the literature to overcome these difficulties. In this paper, we are presenting a series of cases in which a newly modified tendon stripper was used for tendon graft harvesting.

  11. Implantation of a Novel Biologic and Hybridized Tissue Engineered Bioimplant in Large Tendon Defect: An In Vivo Investigation

    PubMed Central

    Oryan, Ahmad; Moshiri, Ali; Parizi, Abdolhamid Meimandi

    2014-01-01

    Surgical reconstruction of large Achilles tendon defects is technically demanding. There is no standard method, and tissue engineering may be a valuable option. We investigated the effects of 3D collagen and collagen-polydioxanone sheath (PDS) implants on a large tendon defect model in rabbits. Ninety rabbits were divided into three groups: control, collagen, and collagen-PDS. In all groups, 2 cm of the left Achilles tendon were excised and discarded. A modified Kessler suture was applied to all injured tendons to retain the gap length. The control group received no graft, the treated groups were repaired using the collagen only or the collagen-PDS prostheses. The bioelectrical characteristics of the injured areas were measured at weekly intervals. The animals were euthanized at 60 days after the procedure. Gross, histopathological and ultrastructural morphology and biophysical characteristics of the injured and intact tendons were investigated. Another 90 pilot animals were also used to investigate the inflammatory response and mechanism of graft incorporation during tendon healing. The control tendons showed severe hyperemia and peritendinous adhesion, and the gastrocnemius muscle of the control animals showed severe atrophy and fibrosis, with a loose areolar connective tissue filling the injured area. The tendons receiving either collagen or collagen-PDS implants showed lower amounts of peritendinous adhesion, hyperemia and muscle atrophy, and a dense tendon filled the defect area. Compared to the control tendons, application of collagen and collagen-PDS implants significantly improved water uptake, water delivery, direct transitional electrical current and tissue resistance to direct transitional electrical current. Compared to the control tendons, both prostheses showed significantly increased diameter, density and alignment of the collagen fibrils and maturity of the tenoblasts at ultrastructure level. Both prostheses influenced favorably tendon healing compared to the control tendons, with no significant differences between collagen and collagen-PDS groups. Implantation of the 3D collagen and collagen-PDS implants accelerated the production of a new tendon in the defect area, and may become a valuable option in clinical practice. PMID:24004331

  12. Focal Experimental Injury Leads to Widespread Gene Expression and Histologic Changes in Equine Flexor Tendons

    PubMed Central

    Jacobsen, Else; Dart, Andrew J.; Mondori, Takamitsu; Horadogoda, Neil; Jeffcott, Leo B.; Little, Christopher B.; Smith, Margaret M.

    2015-01-01

    It is not known how extensively a localised flexor tendon injury affects the entire tendon. This study examined the extent of and relationship between histopathologic and gene expression changes in equine superficial digital flexor tendon after a surgical injury. One forelimb tendon was hemi-transected in six horses, and in three other horses, one tendon underwent a sham operation. After euthanasia at six weeks, transected and control (sham and non-operated contralateral) tendons were regionally sampled (medial and lateral halves each divided into six 3cm regions) for histologic (scoring and immunohistochemistry) and gene expression (real time PCR) analysis of extracellular matrix changes. The histopathology score was significantly higher in transected tendons compared to control tendons in all regions except for the most distal (P ≤ 0.03) with no differences between overstressed (medial) and stress-deprived (lateral) tendon halves. Proteoglycan scores were increased by transection in all but the most proximal region (P < 0.02), with increased immunostaining for aggrecan, biglycan and versican. After correcting for location within the tendon, gene expression for aggrecan, versican, biglycan, lumican, collagen types I, II and III, MMP14 and TIMP1 was increased in transected tendons compared with control tendons (P < 0.02) and decreased for ADAMTS4, MMP3 and TIMP3 (P < 0.001). Aggrecan, biglycan, fibromodulin, and collagen types I and III expression positively correlated with all histopathology scores (P < 0.001), whereas lumican, ADAMTS4 and MMP14 expression positively correlated only with collagen fiber malalignment (P < 0.001). In summary, histologic and associated gene expression changes were significant and widespread six weeks after injury to the equine SDFT, suggesting rapid and active development of tendinopathy throughout the entire length of the tendon. These extensive changes distant to the focal injury may contribute to poor functional outcomes and re-injury in clinical cases. Our data suggest that successful treatments of focal injuries will need to address pathology in the entire tendon, and that better methods to monitor the development and resolution of tendinopathy are required. PMID:25837713

  13. Application of a novel Kalman filter based block matching method to ultrasound images for hand tendon displacement estimation.

    PubMed

    Lai, Ting-Yu; Chen, Hsiao-I; Shih, Cho-Chiang; Kuo, Li-Chieh; Hsu, Hsiu-Yun; Huang, Chih-Chung

    2016-01-01

    Information about tendon displacement is important for allowing clinicians to not only quantify preoperative tendon injuries but also to identify any adhesive scaring between tendon and adjacent tissue. The Fisher-Tippett (FT) similarity measure has recently been shown to be more accurate than the Laplacian sum of absolute differences (SAD) and Gaussian sum of squared differences (SSD) similarity measures for tracking tendon displacement in ultrasound B-mode images. However, all of these similarity measures can easily be influenced by the quality of the ultrasound image, particularly its signal-to-noise ratio. Ultrasound images of injured hands are unfortunately often of poor quality due to the presence of adhesive scars. The present study investigated a novel Kalman-filter scheme for overcoming this problem. Three state-of-the-art tracking methods (FT, SAD, and SSD) were used to track the displacements of phantom and cadaver tendons, while FT was used to track human tendons. These three tracking methods were combined individually with the proposed Kalman-filter (K1) scheme and another Kalman-filter scheme used in a previous study to optimize the displacement trajectories of the phantom and cadaver tendons. The motion of the human extensor digitorum communis tendon was measured in the present study using the FT-K1 scheme. The experimental results indicated that SSD exhibited better accuracy in the phantom experiments, whereas FT exhibited better performance for tracking real tendon motion in the cadaver experiments. All three tracking methods were influenced by the signal-to-noise ratio of the images. On the other hand, the K1 scheme was able to optimize the tracking trajectory of displacement in all experiments, even from a location with a poor image quality. The human experimental data indicated that the normal tendons were displaced more than the injured tendons, and that the motion ability of the injured tendon was restored after appropriate rehabilitation sessions. The obtained results show the potential for applying the proposed FT-K1 method in clinical applications for evaluating the tendon injury level after metacarpal fractures and assessing the recovery of an injured tendon during rehabilitation.

  14. Intravoxel incoherent motion (IVIM) imaging in human achilles tendon.

    PubMed

    Wengler, Kenneth; Fukuda, Takeshi; Tank, Dharmesh; Huang, Mingqian; Gould, Elaine S; Schweitzer, Mark E; He, Xiang

    2018-05-09

    Limited microcirculation has been implicated in Achilles tendinopathy and may affect healing and disease progression. Existing invasive and noninvasive approaches to evaluate tendon microcirculation lack sensitivity and spatial coverage. To develop a novel Achilles tendon intravoxel incoherent motion (IVIM) MRI protocol to overcome the limitations from low tendon T 2 /T 2 * value and low intratendinous blood volume and blood velocity to evaluate tendon microcirculation. Prospective. Sixteen healthy male participants (age 31.0 ± 2.1) were recruited. A stimulated echo readout-segmented echo planar imaging (ste-RS-EPI) IVIM sequence at 3.0T. The feasibility of the proposed ste-RS-EPI IVIM protocol combined with Achilles tendon magic angle effect was evaluated. The sensitivity of the protocol was assessed by an exercise-induced intratendinous hemodynamic response in healthy participants. The vascular origin of the observed IVIM signal was validated by varying the diffusion mixing time and echo time. Two-tailed t-tests were used to evaluate differences (P < 0.05 was considered significant). Consistent with known tendon hypovascularity, the midportion Achilles tendon at baseline showed significantly lower IVIM-derived perfusion fraction (f p ) (3.1 ± 0.9%) compared to the proximal and distal Achilles tendon (6.0 ± 1.8% and 6.1 ± 2.0%, respectively; P < 0.01). Similarly, the midportion Achilles tendon exhibited significantly lower baseline blood flow index (D*×f p ) (40.9 ± 19.2, 18.3 ± 5.3, and 32.0 ± 9.4 in proximal, midportion, and distal Achilles tendon, respectively; P < 0.01). Eccentric heel-raise exercise led to ∼2 times increase of Achilles tendon blood flow in healthy participants. Consistent with its vascular origin, the estimated f p demonstrated a high dependency to IVIM protocol parameters, while the T 1 /T 2 -corrected absolute intratendinous microvascular blood volume fraction (V b ) did not vary. Achilles tendon ste-RS-EPI IVIM noninvasively assessed baseline values and exercise-induced changes to tendon microcirculation in healthy tendon. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Effects of sodium hyaluronate on tendon healing and adhesion formation in horses.

    PubMed

    Gaughan, E M; Nixon, A J; Krook, L P; Yeager, A E; Mann, K A; Mohammed, H; Bartel, D L

    1991-05-01

    Sodium hyaluronate reduces adhesions after tendon repair in rodents and dogs, and has been used in limited clinical trials in people. To evaluate its effect on tendon healing and adhesion formation in horses and to compare these effects with those of a compound of similar visco-elastic properties, a study was performed in horses, using a model of collagenase injection in the flexor tendons within the digital sheath. Eight clinically normal horses were randomly allotted to 2 groups. Adhesion formation between the deep digital flexor tendon and the tendon sheath at the pastern region was induced in the forelimbs of all horses. Using tenoscopic control, a 20-gauge needle was inserted into the deep digital flexor tendon of horses under general anesthesia and 0.2 ml of collagenase (2.5 mg/ml) was injected. The procedure was repeated proximally at 2 other sites, spaced 1.5 cm apart. A biopsy forceps was introduced, and a 5-mm tendon defect was created at each injection site. Group-A horses had 120 mg of sodium hyaluronate (NaHA) gel injected into the tendon sheath of one limb. Group-B horses had methylcellulose gel injected at the same sites. The contralateral limbs of horses in both groups served as surgical, but noninjected, controls. Horses were euthanatized after 8 weeks of stall rest. Ultrasonographic evaluation revealed improved tendon healing after NaHa injection, but no difference in peritendinous adhesion formation. Tendon sheath fluid volume and hyaluronic acid (HA) content were greater in NaHA-treated limbs. Gross pathologic examination revealed considerably fewer and smaller adhesions when limbs were treated with NaHA. However, significant difference in pull-out strengths was not evident between NaHA-treated and control limbs. Histologically, the deep digital flexor tendon from the NaHA-treated limbs had reduced inflammatory cell infiltration, improved tendon structure, and less intratendinous hemorrhage. Treatment with methylcullulose had no significant effect on tendon healing, adhesion size, quantity, or strength or on the volume and composition of the tendon sheath fluid. Sodium hyaluronate, administered intrathecally, appears to have a pharmaceutically beneficial action in this collagenase-induced tendinitis and adhesion model in horses.

  16. Re-generation of tissue about an animal-based scaffold: AMS studies of the fate of the scaffold

    NASA Astrophysics Data System (ADS)

    Rickey, Frank A.; Elmore, David; Hillegonds, Darren; Badylak, Stephen; Record, Rae; Simmons-Byrd, Abby

    2000-10-01

    Small intestinal submucosa (SIS) is an unusual tissue, which shows great promise for the repair of damaged tissues in humans. When the SIS is used as a surgical implant, the porcine-derived material is not rejected by the host immune system, and in fact stimulates the constructive re-modeling of damaged tissue. In dogs, these SIS scaffolds have been used to grow new arteries, tendons, and urinary bladders. Moreover, the SIS scaffold tissue seems to disappear from the implant region after a few months. The fate of this SIS tissue is of considerable importance if it is to be used in human tissue repair. SIS is obtained from pigs. We have labeled the SIS in several pigs by intraveneous administration of 14C enriched proline from the age of three weeks until they reach market weight. The prepared SIS was then implanted in dogs as scaffolds for urinary bladder patches. During the remaining life of each dog, blood, urine and feces samples were collected on a regular schedule. AMS analyses of these specimens were performed to measure the elimination rate of the SIS. At different intervals, the dogs were sacrificed. Tissue samples were analyzed by AMS to determine the whole-body distribution of the labeled SIS.

  17. Extensor Pollicis Longus Injury in Addition to De Quervain’s with Text Messaging on Mobile Phones

    PubMed Central

    Kumar, Bhaskaranand; Bhat, Anil K; Venugopal, Anand

    2014-01-01

    Objective: To do a clinical and ultrasonic evaluation of subjects with thumb pain with text messaging. Background: Thumbs are commonly used for text messaging, which are not as well designed for fine manipulative or dexterous work. Repetitive use as in text messaging can lead to the injury to the tendons of the thumb. Materials and Methods: Ninety eight students with symptoms of Repetitive Strain Type of injuries of the thumb were selected from a survey and evaluated both clinically and by ultrasound analysis of the musculotendinous unit of the thumb to note changes due to excessive use of the mobile phone. Age and sex matched controls were also subjected to ultrasound evaluation. Results: Clinical examination showed positive Finkelstein test in 40% of the cases, significant reduction in the lateral and tip pinch strengths in the cases. Ultrasound detected changes in the first and the third compartments in 19% of the cases. Conclusion: Isolated cases of pain in the thumb have been reported but this study noted changes both clinically and by ultrasound in the tendons of the thumb. These changes should be taken as warning signs of possible subclinical changes taking place in the soft tissues of the thumb in these subjects due to repetitive use of mobile phones and thus, making them prone for developing painful Musculoskeletal Disorders. Application: Repetitive use of mobile phones for text messaging can lead to the damage of Extensor pollicis longus of the thumb in addition to the tendons of the first compartment of the wrist. PMID:25584249

  18. [The mini-open Latarjet procedure for treatment of recurrent anterior instability of the shoulder].

    PubMed

    Pogorzelski, J; Beitzel, K; Imhoff, A B; Braun, S

    2016-12-01

    Shoulder stabilization. Symptomatic recurrent anterior shoulder instability combined with glenoid bone loss of approximately 20-35 % of the glenoid surface, engaging Hill-Sachs lesion and/or previously failed arthroscopic Bankart repair. In patients with a high risk of redislocation (contact sports) or irreparable soft tissue injury the Latarjet procedure can be considered as a first-line treatment. Contraindicated if arthroscopic Bankart repair is possible. Irreparable damage of subscapularis tendon. Bony defect >35 % of the glenoid that cannot be filled with coracoid bone block. Arbitrary shoulder dislocation. Young patients with open growth plates (relative contraindication). Mini-open deltopectoral approach of approximately 6 cm. Preparation of the coracoid process and the conjoined tendons. Osteotomy of the coracoid process at its base using a 90° sawblade. Split of the subscapularis tendon. Preparation of the glenoid defect and implantation of 2-3 suture anchors where appropriate. Drilling of two parallel holes through the coracoid process. Fixation of the bone block with cannulated screws at the anterior glenoid rim and refixation of the joint capsula, if necessary with the help of the suture anchors. Wound drainage and closure in layers. Intermittent immobilization in a sling for 6 weeks with limited abduction, flexion and external rotation. Sport-specific training after 3 months, over-head sports after 6 months. Since 2009 64 mini-open Latarjet procedures (61 patients) performed. In all, 9.4 % of patients suffered from persistent instability (dislocations and subluxations); only 1 patient needed revision surgery due to instability.

  19. [New arthroscopic portal for performing tenotomy/tenodesis procedures on the long head of the biceps brachii tendon].

    PubMed

    Gutiérrez-de la O, Jorge; Espinosa-Uribe, Abraham Guadalupe; Morales-Avalos, Rodolfo; Vílchez-Cavazos, Félix; Elizondo-Omaña, Rodrigo Enrique; Guzmán-López, Santos

    2016-01-01

    Shoulder arthroscopy is the standard technique for performing procedures involving the intertubercular groove. Current techniques continue to produce excessive soft tissue manipulation and neurovascular injury. A cross-sectional, observational and descriptive study was conducted on a cohort of 24 shoulders following the standard surgical protocol and using punch dissection. The neurovascular structures with risk of damage by the standard lateral portal were evaluated during the study to establish a secure area for a new arthroscopic portal. Finally, the safety of the new proposed site was evaluated. The presence of 24 venous structures, with a mean diameter was 1.05mm (SD: 0.71) was documented. A tendency was observed in locating these structures in the lower half of the dissecting field for the left shoulders and a hypovascular area between the 7 and 10hours circle dissected relative to the right shoulder. The new site was determined at a point 1.5 cm anterolateral to the anterolateral border of the acromion at an angle of 60° degrees to the horizontal axis of the acromion and towards the intertubercular groove of the humerus. The methodology used in this study is innovative, reproducible and applicable for the study of all existing shoulder arthroscopic portals procedures, as well as any joint. The results provided by this study will be helpful for clinicians to improve tenotomy/tendon tenodesis procedures of the long head of the biceps brachii tendon. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  20. A cross sectional study of 100 athletes with jumper's knee managed conservatively and surgically. The Victorian Institute of Sport Tendon Study Group.

    PubMed Central

    Cook, J L; Khan, K M; Harcourt, P R; Grant, M; Young, D A; Bonar, S F

    1997-01-01

    OBJECTIVES: Jumper's knee causes significant morbidity in athletes of all standards. However, there are few reference data on the clinical course of this condition in a large number of patients, and the aim of this study was to rectify this. METHODS: A retrospective study of the course of jumper's knee in 100 athletes who presented to a sports medicine clinic over a nine year period was carried out. Subjects completed a questionnaire designed to collect details of sport participation, symptoms, and time out of sport. Ultrasonographic results were recorded from the radiologists' reports. Histopathological results were obtained for patients who had surgery. RESULTS: Forty eight subjects recalled that symptoms of jumper's knee began before the age of 20 years. Symptoms prevented 33 from participating in sport for more than six months, and 18 of these were sidelined for more than 12 months. Forty nine of the subjects had two or more separate episodes of symptoms. Ultrasonography showed a characteristics hypoechoic region at the junction of the inferior pole of the patella and the deep surface of the patellar tendon. Histopathological examination showed separation and disruption of collagen fibres on polarisation light microscopy and an increase in mucoid ground substance consistent with damage of tendon collagen without inflammation. CONCLUSIONS: Jumper's knee has the potential to be a debilitating condition for a sports person. About 33% of athletes presenting to a sports medicine clinic with jumper's knee were unable to return to sport for more than six months. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:9429013

  1. Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology.

    PubMed

    Connizzo, Brianne K; Grodzinsky, Alan J

    2017-03-21

    Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constituents in the tensile response has been studied, their role in compression, particularly in matrix pressurization via regulation of fluid flow, is not well understood. Injured or diseased tendons and tendon regions that naturally experience compression are known to have alterations in glycosaminoglycan content, which could modulate fluid flow and ultimately mechanical function. While recent theoretical studies have predicted tendon mechanics using poroelastic theory, no experimental data have directly demonstrated such behavior. In this study, we use high-bandwidth AFM-based rheology to determine the dynamic response of tendons to compressive loading at the nanoscale and to determine the presence of poroelastic behavior. Tendons are found to have significant characteristic dynamic relaxation behavior occurring at both low and high frequencies. Classic poroelastic behavior is observed, although we hypothesize that the full dynamic response is caused by a combination of flow-dependent poroelasticity as well as flow-independent viscoelasticity. Tendons also demonstrate regional dependence in their dynamic response, particularly near the junction of tendon and bone, suggesting that the structural and compositional heterogeneity in tendon may be responsible for regional poroelastic behavior. Overall, these experiments provide the foundation for understanding fluid-flow-dependent poroelastic mechanics of tendon, and the methodology is valuable for assessing changes in tendon matrix compressive behavior at the nanoscale. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Proteomic analysis reveals age-related changes in tendon matrix composition, with age- and injury-specific matrix fragmentation.

    PubMed

    Peffers, Mandy J; Thorpe, Chavaunne T; Collins, John A; Eong, Robin; Wei, Timothy K J; Screen, Hazel R C; Clegg, Peter D

    2014-09-12

    Energy storing tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), are highly prone to injury, the incidence of which increases with aging. The cellular and molecular mechanisms that result in increased injury in aged tendons are not well established but are thought to result in altered matrix turnover. However, little attempt has been made to fully characterize the tendon proteome nor determine how the abundance of specific tendon proteins changes with aging and/or injury. The aim of this study was, therefore, to assess the protein profile of normal SDFTs from young and old horses using label-free relative quantification to identify differentially abundant proteins and peptide fragments between age groups. The protein profile of injured SDFTs from young and old horses was also assessed. The results demonstrate distinct proteomic profiles in young and old tendon, with alterations in the levels of proteins involved in matrix organization and regulation of cell tension. Furthermore, we identified several new peptide fragments (neopeptides) present in aged tendons, suggesting that there are age-specific cleavage patterns within the SDFT. Proteomic profile also differed between young and old injured tendon, with a greater number of neopeptides identified in young injured tendon. This study has increased the knowledge of molecular events associated with tendon aging and injury, suggesting that maintenance and repair of tendon tissue may be reduced in aged individuals and may help to explain why the risk of injury increases with aging. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  3. The Location-Specific Role of Proteoglycans in the Flexor Carpi Ulnaris Tendon

    PubMed Central

    Buckley, Mark R.; Huffman, George R.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2015-01-01

    Tendons like the flexor carpi ulnaris (FCU) that contain region-specific distributions of proteoglycans (PGs) as a result of the heterogeneous, multi-axial loads they are subjected to in vivo provide valuable models for understanding structure-function relationships in connective tissues. However, the contributions of specific PGs to FCU tendon mechanical properties are unknown. Therefore, the objective of this study was to determine how the location-dependent, viscoelastic mechanical properties of the FCU tendon are impacted individually by PG-associated glycosaminoglycans (GAGs) and by two small leucine-rich proteoglycans (SLRPs), biglycan and decorin. Full length FCU tendons from biglycan- and decorin-null mice were compared to wild type mice to evaluate the effects of specific SLRPs, while chondroitinase ABC digestion of isolated specimens removed from the tendon midsubstance was used to determine how chontroitin/dermatan sulfate (CS/DS) GAGs impact mechanics in mature FCU tendons. A novel combined genetic knockout/ digestion technique also was employed to compare SLRP-null and wild-type tendons in the absence of CS/DS GAGs that may impact properties in the mature state. In all genotypes, mechanical properties in the FCU tendon midsubstance were not affected by GAG digestion. Full-length tendons exhibited complex, multi-axial deformation under tension that may be associated with their in vivo loading environment. Mechanical properties were adversely affected by the absence of biglycan, and a decreased modulus localized in the center of the tendon was measured. These results help elucidate the role that local alterations in proteoglycan levels may play in processes that adversely impact tendon functionality including injury and pathology. PMID:23941206

  4. Regional stiffening with aging in tibialis anterior tendons of mice occurs independent of changes in collagen fibril morphology

    PubMed Central

    Wood, Lauren K.; Arruda, Ellen M.

    2011-01-01

    The incidence of tendon degeneration and rupture increases with advancing age. The mechanisms underlying this increased risk remain unknown but may arise because of age-related changes in tendon mechanical properties and structure. Our purpose was to determine the effect of aging on tendon mechanical properties and collagen fibril morphology. Regional mechanical properties and collagen fibril characteristics were determined along the length of tibialis anterior (TA) tendons from adult (8- to 12-mo-old) and old (28- to 30-mo-old) mice. Tangent modulus of all regions along the tendons increased in old age, but the increase was substantially greater in the proximal region adjacent to the muscle than in the rest of the tendon. Overall end-to-end modulus increased with old age at maximum tendon strain (799 ± 157 vs. 1,419 ± 91 MPa) and at physiologically relevant strain (377 ± 137 vs. 798 ± 104 MPa). Despite the dramatic changes in tendon mechanical properties from adulthood to old age, collagen fibril morphology and packing fraction remained relatively constant in all tendon regions examined. Since tendon properties are influenced by their external loading environment, we also examined the effect of aging on TA muscle contractile properties. Maximum isometric force did not differ between the age groups. We conclude that TA tendons stiffen in a region-dependent manner throughout the life span, but the changes in mechanical properties are not accompanied by corresponding changes in collagen fibril morphology or force-generating capacity of the TA muscle. PMID:21737825

  5. Scaffolds in Tendon Tissue Engineering

    PubMed Central

    Longo, Umile Giuseppe; Lamberti, Alfredo; Petrillo, Stefano; Maffulli, Nicola; Denaro, Vincenzo

    2012-01-01

    Tissue engineering techniques using novel scaffold materials offer potential alternatives for managing tendon disorders. Tissue engineering strategies to improve tendon repair healing include the use of scaffolds, growth factors, cell seeding, or a combination of these approaches. Scaffolds have been the most common strategy investigated to date. Available scaffolds for tendon repair include both biological scaffolds, obtained from mammalian tissues, and synthetic scaffolds, manufactured from chemical compounds. Preliminary studies support the idea that scaffolds can provide an alternative for tendon augmentation with an enormous therapeutic potential. However, available data are lacking to allow definitive conclusion on the use of scaffolds for tendon augmentation. We review the current basic science and clinical understanding in the field of scaffolds and tissue engineering for tendon repair. PMID:22190961

  6. Distal Attachment of Flexor Tendon Allograft: A Biomechanical Study of Different Reconstruction Techniques in Human Cadaver Hands

    PubMed Central

    Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2014-01-01

    We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507

  7. Ultrasonographic assessment of the equine palmar tendons

    PubMed Central

    Padaliya, N. R.; Ranpariya, J. J.; Kumar, Dharmendra; Javia, C. B.; Barvalia, D. R.

    2015-01-01

    Aim: The present study was conducted to evaluate the equine palmar tendon by ultrasonography (USG) in standing the position. Materials and Methods: USG of palmar tendons was performed in 40 adult horses using linear transducer having frequency of 10-18 MHz (e-soate, My Lab FIVE) and L52 linear array transducer (Titan, SonoSite) with frequencies ranging from 8 to 10 MHz. Palmar tendon was divided into 7 levels from distal to accessory carpal bone up to ergot in transverse scanning and 3 levels in longitudinal scanning. Results: The USG evaluation was very useful for diagnosis of affections of the conditions such as chronic bowed tendon, suspensory ligament desmitis, carpal sheath tenosynovitis and digital sheath effusions. The mean cross-sectional area (cm2) of affected tendons was significantly increased in affected than normal tendons. The echogenicity was also found reduced in affected tendons and ligaments along with disorganization of fiber alignment depending on the severity of lesion and injury. Conclusion: USG proved ideal diagnostic tool for diagnosis and post-treatment healing assessment of tendon injuries in horses. PMID:27047074

  8. Validation of Greyscale-Based Quantitative Ultrasound in Manual Wheelchair Users

    PubMed Central

    Collinger, Jennifer L.; Fullerton, Bradley; Impink, Bradley G.; Koontz, Alicia M.; Boninger, Michael L.

    2010-01-01

    Objective The primary aim of this study is to establish the validity of greyscale-based quantitative ultrasound (QUS) measures of the biceps and supraspinatus tendons. Design Nine QUS measures of the biceps and supraspinatus tendons were computed from ultrasound images collected from sixty-seven manual wheelchair users. Shoulder pathology was measured using questionnaires, physical examination maneuvers, and a clinical ultrasound grading scale. Results Increased age, duration of wheelchair use, and body mass correlated with a darker, more homogenous tendon appearance. Subjects with pain during physical examination tests for biceps tenderness and acromioclavicular joint tenderness exhibited significantly different supraspinatus QUS values. Even when controlling for tendon depth, QUS measures of the biceps tendon differed significantly between subjects with healthy tendons, mild tendinosis, and severe tendinosis. Clinical grading of supraspinatus tendon health was correlated with QUS measures of the supraspinatus tendon. Conclusions Quantitative ultrasound is valid method to quantify tendinopathy and may allow for early detection of tendinosis. Manual wheelchair users are at a high risk for developing shoulder tendon pathology and may benefit from quantitative ultrasound-based research that focuses on identifying interventions designed to reduce this risk. PMID:20407304

  9. The role of the non-collagenous matrix in tendon function.

    PubMed

    Thorpe, Chavaunne T; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2013-08-01

    Tendon consists of highly ordered type I collagen molecules that are grouped together to form subunits of increasing diameter. At each hierarchical level, the type I collagen is interspersed with a predominantly non-collagenous matrix (NCM) (Connect. Tissue Res., 6, 1978, 11). Whilst many studies have investigated the structure, organization and function of the collagenous matrix within tendon, relatively few have studied the non-collagenous components. However, there is a growing body of research suggesting the NCM plays an important role within tendon; adaptations to this matrix may confer the specific properties required by tendons with different functions. Furthermore, age-related alterations to non-collagenous proteins have been identified, which may affect tendon resistance to injury. This review focuses on the NCM within the tensional region of developing and mature tendon, discussing the current knowledge and identifying areas that require further study to fully understand structure-function relationships within tendon. This information will aid in the development of appropriate techniques for tendon injury prevention and treatment. © 2013 The Authors. International Journal of Experimental Pathology © 2013 International Journal of Experimental Pathology.

  10. Hydroxyapatite-doped polycaprolactone nanofiber membrane improves tendon-bone interface healing for anterior cruciate ligament reconstruction.

    PubMed

    Han, Fei; Zhang, Peng; Sun, Yaying; Lin, Chao; Zhao, Peng; Chen, Jiwu

    2015-01-01

    Hamstring tendon autograft is a routine graft for anterior cruciate ligament (ACL) reconstruction. However, ways of improving the healing between the tendon and bone is often overlooked in clinical practice. This issue can be addressed by using a biomimetic scaffold. Herein, a biomimetic nanofiber membrane of polycaprolactone/nanohydroxyapatite/collagen (PCL/nHAp/Col) is fabricated that mimics the composition of native bone tissue for promoting tendon-bone healing. This membrane has good cytocompatibility, allowing for osteoblast cell adhesion and growth and bone formation. As a result, MC3T3 cells reveal a higher mineralization level in PCL/nHAp/Col membrane compared with PCL membrane alone. Further in vivo studies in ACL reconstruction in a rabbit model shows that PCL/nHAp/Col-wrapped tendon may afford superior tissue integration to nonwrapped tendon in the interface between the tendon and host bone as well as improved mechanical strength. This study shows that PCL/nHAp/Col nanofiber membrane wrapping of autologous tendon is effective for improving tendon healing with host bone in ACL reconstruction.

  11. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    PubMed Central

    Young, Mark

    2012-01-01

    Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use. PMID:22448174

  12. Surface Modification with Chemically Modified Synovial Fluid for Flexor Tendon Reconstruction in a Canine Model in Vivo

    PubMed Central

    Ji, Xiaoxi; Reisdorf, Ramona L.; Thoreson, Andrew R.; Berglund, Lawrence R.; Moran, Steven L.; Jay, Gregory D.; An, Kai-Nan; Amadio, Peter C.; Zhao, Chunfeng

    2015-01-01

    Background: Functional restoration is the major concern after flexor tendon reconstruction in the hand. The purpose of the present study was to investigate the effects of modifying the surface of extrasynovial tendon autografts with carbodiimide-derivatized synovial fluid with gelatin (cd-SF-G) on functional outcomes of flexor tendon reconstruction using a canine model. Methods: The second and fifth flexor digitorum profundus tendons from eleven dogs were transected and repaired in zone II. The dogs then had six weeks of free activity leading to tendon rupture and scar formation (the repair-failure phase). In the reconstruction phase, two autologous peroneus longus tendons from each dog were harvested; one tendon was coated with cd-SF-G and the other, with saline solution, as a control. A non-weight-bearing rehabilitation protocol was followed for six weeks after reconstruction. The digits were then harvested and evaluations of function, adhesion status, gliding resistance, attachment strength, cell viability, and histology were performed. Results: The tendons coated with cd-SF-G demonstrated significantly lower values (mean and standard deviation) compared with the saline-solution group for work of flexion (0.63 ± 0.24 versus 1.34 ± 0.42 N-mm/deg), adhesion score (3.5 ± 1.6 versus 6.1 ± 1.3), proximal adhesion breaking force (8.6 ± 3.2 versus 20.2 ± 10.2 N), and gliding resistance (0.26 ± 0.08 versus 0.46 ± 0.22 N) (p < 0.05). There was no significant difference between the cd-SF-G and saline-solution groups (p > 0.05) in distal attachment-site strength (56.9 ± 28.4 versus 77.2 ± 36.2 N), stiffness (19 ± 7.5 versus 24.5 ± 14.5 N/mm), and compressive modulus from indentation testing (4.37 ± 1.26 versus 3.98 ± 1.24 N/mm). Histological analysis showed that tendons coated with cd-SF-G had smoother surfaces and demonstrated tendon-to-bone and tendon-to-tendon incorporation. No significant difference in viable cell count between the two groups was observed on tendon culture. Conclusions: Modification of the flexor tendon surface with cd-SF-G significantly improved digital function and reduced adhesion formation without affecting graft healing and stiffness. Clinical Relevance: This study used native synovial fluid as a basic lubricating reagent to treat a tendon graft in vivo, a novel avenue for improving clinical outcomes of flexor tendon reconstruction. This methodology may also apply to other surgical procedures where postoperative adhesions impair function. PMID:26085530

  13. Etiology, Diagnosis and Treatment of Tendinous Knee Extensor Mechanism Injuries.

    PubMed

    Ibounig, T; Simons, T A

    2016-06-01

    Quadriceps and patella tendon ruptures are uncommon injuries often resulting from minor trauma typically consisting of an eccentric contraction of the quadriceps muscle. Since rupture of a healthy tendon is very rare, such injuries usually represent the end stage of a long process of chronic tendon degeneration and overuse. This review aims to give an overview of the current understanding of the pathophysiology, diagnostic principles, and recommended treatment protocols as supported by the literature and institutional experience. A non-systematic review of the current literature on the subject was conducted and reflected against the current practice in our level 1 trauma center. Risk factors for patella and quadriceps tendon rupture include increasing age, repetitive micro-trauma, genetic predisposition, and systemic diseases, as well as certain medications. Diagnosis is based on history and clinical findings, but can be complemented by ultrasound or magnetic resonance imaging. Accurate diagnosis at an early stage is of utmost importance since delay in surgical repair of over 3 weeks results in significantly poorer outcomes. Operative treatment of acute ruptures yields good clinical results with low complication rates. Use of longitudinal transpatellar drill holes is the operative method of choice in the majority of acute cases. In chronic ruptures, tendon augmentation with auto- or allograft should be considered. Postoperative treatment protocols in the literature range from early mobilization with full weight bearing to cast immobilization for up to 12 weeks. Respecting the biology of tendon healing, we advocate the use of a removable knee splint or orthotic with protected full weight bearing and limited passive mobilization for 6 weeks. © The Finnish Surgical Society 2015.

  14. Association Between Years of Competition and Shoulder Function in Collegiate Swimmers.

    PubMed

    Dischler, Jack D; Baumer, Timothy G; Finkelstein, Evan; Siegal, Daniel S; Bey, Michael J

    Shoulder injuries are common among competitive swimmers, and the progression of shoulder pathology is not well understood. The objective of this study was to assess the extent to which years of competitive swim training were associated with physical properties of the supraspinatus muscle and tendon, shoulder strength, and self-reported assessments of shoulder pain and function. Increasing years of competition will be associated with declining physical properties of the supraspinatus muscle/tendon and declining self-reported assessments of pain and function. Descriptive epidemiology study. Level 4. After institutional approval, 18 collegiate female swimmers enrolled in the study. For each swimmer, supraspinatus tendon thickness was measured; tendinosis was assessed using ultrasound imaging, supraspinatus muscle shear wave velocity was assessed using shear wave elastography, isometric shoulder strength was measured using a Biodex system, and self-reported assessments of pain/function were assessed using the Western Ontario Rotator Cuff (WORC) score. All subjects were tested before the start of the collegiate swim season. Linear regression was used to assess the association between years of competition and the outcome measures. Years of participation was positively associated with tendon thickness ( P = 0.01) and negatively associated with shear wave velocity ( P = 0.04) and WORC score ( P < 0.01). Shoulder strength was not associated with years of participation ( P > 0.39). Long-term competitive swim training is associated with declining measures of supraspinatus muscle/tendon properties and self-reported measures of pain and function. Although specific injury mechanisms are still not fully understood, these findings lend additional insight into the development of rotator cuff pathology in swimmers. Lengthy swimming careers may lead to a chronic condition of reduced mechanical properties in the supraspinatus muscle and tendon, thereby increasing the likelihood of rotator cuff pathology.

  15. Primary and Secondary Consequences of Rotator Cuff Injury on Joint Stabilizing Tissues in the Shoulder.

    PubMed

    Rahman, Hafizur; Currier, Eric; Johnson, Marshall; Goding, Rick; Johnson, Amy Wagoner; Kersh, Mariana E

    2017-11-01

    Rotator cuff tears (RCTs) are one of the primary causes of shoulder pain and dysfunction in the upper extremity accounting over 4.5 million physician visits per year with 250,000 rotator cuff repairs being performed annually in the U.S. While the tear is often considered an injury to a specific tendon/tendons and consequently treated as such, there are secondary effects of RCTs that may have significant consequences for shoulder function. Specifically, RCTs have been shown to affect the joint cartilage, bone, the ligaments, as well as the remaining intact tendons of the shoulder joint. Injuries associated with the upper extremities account for the largest percent of workplace injuries. Unfortunately, the variable success rate related to RCTs motivates the need for a better understanding of the biomechanical consequences associated with the shoulder injuries. Understanding the timing of the injury and the secondary anatomic consequences that are likely to have occurred are also of great importance in treatment planning because the approach to the treatment algorithm is influenced by the functional and anatomic state of the rotator cuff and the shoulder complex in general. In this review, we summarized the contribution of RCTs to joint stability in terms of both primary (injured tendon) and secondary (remaining tissues) consequences including anatomic changes in the tissues surrounding the affected tendon/tendons. The mechanical basis of normal shoulder joint function depends on the balance between active muscle forces and passive stabilization from the joint surfaces, capsular ligaments, and labrum. Evaluating the role of all tissues working together as a system for maintaining joint stability during function is important to understand the effects of RCT, specifically in the working population, and may provide insight into root causes of shoulder injury.

  16. Arthroscopic transtendinous repair of articular-sided pasta (partial articular supraspinatus tendon avulsion) injury.

    PubMed

    Wang, Yi; Lu, Liangyu; Lu, Zhe; Xiao, Lei; Kang, Yifan; Wang, Zimin

    2015-01-01

    To evaluate clinical efficacy of arthroscopic transtendinous repair of partial articular-sided PASTA (partial articular supraspinatus tendon avulsion) injury. From February 2011 to July 2014, 12 cases of PASTA, aged 29 to 72 years with an average of 52.9 ± 13.3 years, were treated arthoscopically. To repair PASTA, articular-sided rotator cuff tear was explored, injury site was punctured and labeled with PDS absorbable monofilament suture (Ethicon, Somerville, NJ, USA) suture, subacromial bursa was cleaned up with acromioplasty, and integrity of bursa-side rotator cuff was assessed. Then with arthroscope in glenohumeral joint, footprint of the bursa-side supraspinatus tendon was preserved, rivets were introduced into the joint through supraspinatus tendon, joint-side partial tear was sutured, and anatomical reconstruction of the rotator cuff footprint was established. The patients were followed up post-operatively for 12-36 months, average 22 ± 7.3 months. The clinical outcomes were emulated with ASES (American Shoulder and Elbow Surgeons) Shoulder Score system and UCLA (University of California at Los Angeles) Shoulder rating scale. The post-operative ASES score was 89.7 ± 5.6, higher than the pre-operative one 49.8 ± 9.8 (t = 12.25, P <0.0001). While UCLA scale increased from the pre-operative 17.3, ± 3.3 to the post-operative 30.4 ± 3.2 points (t = 9.87, P <0.0001), with a satisfaction rate of 11/12 (91.7%). Trans-tendon repair is ideal for PASTA with advantage of maximal preservation of the normal rotator cuff tissue, anatomical reconstruction of the rotator cuff footprint and stable fixation of tendon-bone interface.

  17. Pentadecapeptide BPC 157 enhances the growth hormone receptor expression in tendon fibroblasts.

    PubMed

    Chang, Chung-Hsun; Tsai, Wen-Chung; Hsu, Ya-Hui; Pang, Jong-Hwei Su

    2014-11-19

    BPC 157, a pentadecapeptide derived from human gastric juice, has been demonstrated to promote the healing of different tissues, including skin, muscle, bone, ligament and tendon in many animal studies. However, the underlying mechanism has not been fully clarified. The present study aimed to explore the effect of BPC 157 on tendon fibroblasts isolated from Achilles tendon of male Sprague-Dawley rat. From the result of cDNA microarray analysis, growth hormone receptor was revealed as one of the most abundantly up-regulated genes in tendon fibroblasts by BPC 157. BPC 157 dose- and time-dependently increased the expression of growth hormone receptor in tendon fibroblasts at both the mRNA and protein levels as measured by RT/real-time PCR and Western blot, respectively. The addition of growth hormone to BPC 157-treated tendon fibroblasts dose- and time-dependently increased the cell proliferation as determined by MTT assay and PCNA expression by RT/real-time PCR. Janus kinase 2, the downstream signal pathway of growth hormone receptor, was activated time-dependently by stimulating the BPC 157-treated tendon fibroblasts with growth hormone. In conclusion, the BPC 157-induced increase of growth hormone receptor in tendon fibroblasts may potentiate the proliferation-promoting effect of growth hormone and contribute to the healing of tendon.

  18. Pitfalls during biomechanical testing - Evaluation of different fixation methods for measuring tendons endurance properties.

    PubMed

    Hangody, Gy; Pánics, G; Szebényi, G; Kiss, R; Hangody, L; Pap, K

    2016-03-01

    The goal of the study was to find a proper technique to fix tendon grafts into an INSTRON loading machine. From 8 human cadavers, 40 grafts were collected. We removed the bone-patella tendon-bone grafts, the semitendinosus and gracilis tendons, the quadriceps tendon-bone grafts, the Achilles tendons, and the peroneus longus tendons from each lower extremity. We tested the tendon grafts with five different types of fixation devices: surgical thread (Premicron 3), general mounting clamp, wire mesh, cement fixation, and a modified clamp for an INSTRON loading machine. The mean failure load in case of surgical thread fixation was (381N ± 26N). The results with the general clamp were (527N ± 45N). The wire meshes were more promising (750N ± 21N), but did not reach the outcomes we desired. Easy slippages of the ends of the tendons from the cement encasements were observed (253N ± 18N). We then began to use Shi's clamp that could produce 977N ± 416N peak force. We combined Shi's clamp with freezing of the graft and the rupture of the tendon itself demonstrated an average force of 2198 N ± 773N. We determined that our modified frozen clamp fixed the specimens against high tensile forces.

  19. Achilles tendon shape and echogenicity on ultrasound among active badminton players.

    PubMed

    Malliaras, P; Voss, C; Garau, G; Richards, P; Maffulli, N

    2012-04-01

    The relationship between Achilles tendon ultrasound abnormalities, including a spindle shape and heterogeneous echogenicity, is unclear. This study investigated the relationship between these abnormalities, tendon thickness, Doppler flow and pain. Sixty-one badminton players (122 tendons, 36 men, and 25 women) were recruited. Achilles tendon thickness, shape (spindle, parallel), echogenicity (heterogeneous, homogeneous) and Doppler flow (present or absent) were measured bilaterally with ultrasound. Achilles tendon pain (during or after activity over the last week) and pain and function [Victorian Institute of Sport Achilles Assessment (VISA-A)] were measured. Sixty-eight (56%) tendons were parallel with homogeneous echogenicity (normal), 22 (18%) were spindle shaped with homogeneous echogenicity, 16 (13%) were parallel with heterogeneous echogenicity and 16 (13%) were spindle shaped with heterogeneous echogenicity. Spindle shape was associated with self-reported pain (P<0.05). Heterogeneous echogenicity was associated with lower VISA-A scores than normal tendon (P<0.05). There was an ordinal relationship between normal tendon, parallel and heterogeneous and spindle shaped and heterogeneous tendons with regard to increasing thickness and likelihood of Doppler flow. Heterogeneous echogenicity with a parallel shape may be a physiological phase and may develop into heterogeneous echogenicity with a spindle shape that is more likely to be pathological. © 2010 John Wiley & Sons A/S.

  20. Diabetes Alters Mechanical Properties and Collagen Fiber Re-Alignment in Multiple Mouse Tendons

    PubMed Central

    Connizzo, Brianne K.; Bhatt, Pankti R.; Liechty, Kenneth W.; Soslowsky, Louis J.

    2014-01-01

    Tendons function to transfer load from muscle to bone through their complex composition and hierarchical structure, consisting mainly of type I collagen. Recent evidence suggests that type II diabetes may cause alterations in collagen structure, such as irregular fibril morphology and density, which could play a role in the mechanical function of tendons. Using the db/db mouse model of type II diabetes, the diabetic skin was found to have impaired biomechanical properties when compared to the non-diabetic group. The purpose of this study was to assess the effect of diabetes on biomechanics, collagen fiber re-alignment, and biochemistry in three functionally different tendons (Achilles, supraspinatus, patellar) using the db/db mouse model. Results showed that cross-sectional area and stiffness, but not modulus, were significantly reduced in all three tendons. However, the tendon response to load (transition strain, collagen fiber re-alignment) occurred earlier in the mechanical test, contrary to expectations. In addition, the patellar tendon had an altered response to diabetes when compared to the other two tendons, with no changes in fiber realignment and decreased collagen content at the midsubstance of the tendon. Overall, type II diabetes alters tendon mechanical properties and the dynamic response to load. PMID:24833253

  1. Effects of Trypsinization and Mineralization on Intrasynovial Tendon Allograft Healing to Bone

    PubMed Central

    Qu, Jin; van Alphen, Nick A.; Thoreson, Andrew R.; Chen, Qingshan; An, Kai-Nan; Amadio, Peter C.; Schmid, Thomas M.; Zhao, Chunfeng

    2014-01-01

    The purpose of the current study was to develop a novel technology to enhance tendon-to-bone interface healing by trypsinizing and mineralizing (TM) an intrasynovial tendon allograft in a rabbit bone tunnel model. Eight rabbit flexor digitorum profundus (FDP) tendons were used to optimize the trypsinization process. An additional 24 FDP tendons were stratified into control and TM groups; in each group, 4 tendons were used for in vitro evaluation of TM and 8 were transplanted into proximal tibial bone tunnels in rabbits. The samples were evaluated histologically and with mechanical testing at postoperative week 8. Maximum failure strength and linear stiffness were not significantly different between the control and TM tendons. A thin fibrous band of scar tissue formed at the graft-to-bone interface in the control group. However, only the TM group showed obvious new bone formation inside the tendon graft and a visible fibrocartilage layer at the bone tunnel entrance. This study is the first to explore effects of TM on the intrasynovial allograft healing to a bone tunnel. TM showed beneficial effects on chondrogenesis, osteogenesis, and integration of the intrasynovial tendon graft, but mechanical strength was the same as the control tendons in this short-term in vivo study. PMID:25611186

  2. Tendon sheath fibroma in the thigh.

    PubMed

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  3. Time-Dependent Alterations of MMPs, TIMPs and Tendon Structure in Human Achilles Tendons after Acute Rupture

    PubMed Central

    Minkwitz, Susann; Schmock, Aysha; Kurtoglu, Alper; Tsitsilonis, Serafeim; Manegold, Sebastian; Klatte-Schulz, Franka

    2017-01-01

    A balance between matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) is required to maintain tendon homeostasis. Variation in this balance over time might impact on the success of tendon healing. This study aimed to analyze structural changes and the expression profile of MMPs and TIMPs in human Achilles tendons at different time-points after rupture. Biopsies from 37 patients with acute Achilles tendon rupture were taken at surgery and grouped according to time after rupture: early (2–4 days), middle (5–6 days), and late (≥7 days), and intact Achilles tendons served as control. The histological score increased from the early to the late time-point after rupture, indicating the progression towards a more degenerative status. In comparison to intact tendons, qRT-PCR analysis revealed a significantly increased expression of MMP-1, -2, -13, TIMP-1, COL1A1, and COL3A1 in ruptured tendons, whereas TIMP-3 decreased. Comparing the changes over time post rupture, the expression of MMP-9, -13, and COL1A1 significantly increased, whereas MMP-3 and -10 expression decreased. TIMP expression was not significantly altered over time. MMP staining by immunohistochemistry was positive in the ruptured tendons exemplarily analyzed from early and late time-points. The study demonstrates a pivotal contribution of all investigated MMPs and TIMP-1, but a minor role of TIMP-2, -3, and -4, in the early human tendon healing process. PMID:29053586

  4. Incidence and clinical outcomes of tendon rupture following distal radius fracture.

    PubMed

    White, Brian D; Nydick, Jason A; Karsky, Dawnne; Williams, Bailee D; Hess, Alfred V; Stone, Jeffrey D

    2012-10-01

    To evaluate the incidence of tendon rupture after nonoperative and operative management of distal radius fractures, report clinical outcomes after tendon repair or transfer, and examine volar plate and dorsal screw prominence as a predictor of tendon rupture. We performed a retrospective chart review on patients treated for tendon rupture after distal radius fracture. We evaluated active range of motion, Disabilities of Arm, Shoulder, and Hand score, grip strength, and pain score, and performed radiographic evaluation of volar plate and dorsal screw prominence in both the study group and a matched control group. There were 6 tendon ruptures in 1,359 patients (0.4%) treated nonoperatively and 8 tendon ruptures in 999 patients (0.8%) treated with volar plate fixation. At the time of final follow-up, regardless of treatment, we noted that patients had minimal pain and excellent motion and grip strength. Mean Disabilities of the Shoulder, Arm, and Hand scores were 6 for patients treated nonoperatively and 4 for those treated with volar plating. We were unable to verify volar plate or dorsal screw prominence as independent risk factors for tendon rupture after distal radius fractures. However, we recommend continued follow-up and plate removal for symptomatic patients who have volar plate prominence or dorsal screw prominence. In the event of tendon rupture, we report excellent clinical outcomes after tendon repair or tendon transfer. Therapeutic IV. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Is the chronic painful tendinosis tendon a strong tendon?: a case study involving an Olympic weightlifter with chronic painful Jumper's knee.

    PubMed

    Gisslén, Karl; Ohberg, Lars; Alfredson, Håkan

    2006-09-01

    The chronic painful tendinosis tendon is generally considered a degenerated and weak tendon. However, this has not been scientifically verified, and is to be considered a hypothesis. We present here a case study involving a high-level Olympic weightlifter with chronic painful patellar tendinosis who started heavy-weight training very early after successful treatment with sclerosing injections. A 25-year-old super heavy-weight (+105 kg) Olympic weightlifter with 9 months duration of severe pain (prohibiting full training) in the proximal patellar tendon, where ultrasound and Doppler showed a widened tendon with structural changes and neovascularisation, was given one treatment with ultrasound and Doppler-guided injections of the sclerosing agent polidocanol. The injections targeted the neovessels posterior to the tendon. The patient was pain-free after the treatment, and already after 2-weeks he started with heavy-weight training (240 kg in deep squats) to try to qualify for the Olympics. Additional very heavy training on training camps, most often without having any discomfort or pain in the patellar tendon, resulted in Swedish records and ninth place at the European Championships 17 weeks after the treatment. Despite beating the national records, he did not qualify for the Olympics. Ultrasound and Doppler follow-ups have shown only a few remaining neovessels, and little structural tendon changes. This case questions previous theories about the weak tendinosis tendon, and stresses the importance of studies evaluating tendon strength.

  6. Patients with n-hexane induced polyneuropathy: a clinical follow up.

    PubMed Central

    Chang, Y C

    1990-01-01

    The prognosis of hexacarbon induced polyneuropathy is usually good, though its clinical course after the cessation of exposure has not been described in detail. Eleven patients with moderate to severe n-hexane induced polyneuropathy due to occupational exposure were regularly followed up for a period of four years at the neurological department of the National Taiwan University Hospital. Sensorimotor neuropathy was diagnosed in nine patients and motor neuropathy in two. All were removed from further exposure to n-hexane after aetiological confirmation, but motor disturbance continued to worsen in five cases. Sensory functions were regained earlier than motor functions. All the patients, including one who was tetraplegic and confined to a wheelchair in the early stages, regained their full motor capabilities within one to four years. Three patients with severe neuropathy had residual muscle atrophy in the intrinsic foot and hand muscles. Signs of damage to the central nervous system, including increased tendon reflexes in two patients and leg tightness in six patients, emerged as muscle power was nearing complete recovery. The tightness of the legs gradually disappeared, but muscle cramps of the calves developed and these were still present at the end of follow up. Two patients had mild abnormal colour vision, and the abnormality was still detectable four years later. It is concluded that n-hexane induced neuropathy has a good prognosis, and that spasticity due to damage to the central nervous system is functionally reversible; muscle cramps and dyschromatopsia persist much longer. PMID:2166555

  7. Surgical Treatment for Failure of Repair of Patellar and Quadriceps Tendon Rupture With Ipsilateral Hamstring Tendon Graft.

    PubMed

    Maffulli, Nicola; Papalia, Rocco; Torre, Guglielmo; Denaro, Vincenzo

    2017-03-01

    Tears of the patellar and quadriceps tendon are common in the active population, especially in athletes. At present, several techniques for surgical repair and reconstruction are available. When reruptures occur, a reconstruction is mandatory. In the present paper, we describe a surgical technique for patellar and quadriceps tendon reconstruction using ipsilateral hamstring autograft. After routine hamstring tendon harvesting, the tendon ends are prepared using a whip stitch. A transverse tunnel is drilled in the midportion of the patella, the hamstring graft is passed through the patella, and firmly secured to the patellar tunnel openings with sutures. The details of the technique are fully described. Autologous ipsilateral hamstring tendon grafts provide a secure sound means to manage these challenging injuries.

  8. Dental pulp stem cells express tendon markers under mechanical loading and are a potential cell source for tissue engineering of tendon-like tissue.

    PubMed

    Chen, Yu-Ying; He, Sheng-Teng; Yan, Fu-Hua; Zhou, Peng-Fei; Luo, Kai; Zhang, Yan-Ding; Xiao, Yin; Lin, Min-Kui

    2016-12-16

    Postnatal mesenchymal stem cells have the capacity to differentiate into multiple cell lineages. This study explored the possibility of dental pulp stem cells (DPSCs) for potential application in tendon tissue engineering. The expression of tendon-related markers such as scleraxis, tenascin-C, tenomodulin, eye absent homologue 2, collagens I and VI was detected in dental pulp tissue. Interestingly, under mechanical stimulation, these tendon-related markers were significantly enhanced when DPSCs were seeded in aligned polyglycolic acid (PGA) fibre scaffolds. Furthermore, mature tendon-like tissue was formed after transplantation of DPSC-PGA constructs under mechanical loading conditions in a mouse model. This study demonstrates that DPSCs could be a potential stem cell source for tissue engineering of tendon-like tissue.

  9. Tendon Functional Extracellular Matrix

    PubMed Central

    Screen, H.R.C.; Birk, D.E.; Kadler, K.E.; Ramirez, F; Young, M.F.

    2015-01-01

    This article is one of a series, summarising views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the “Functional Extracellular Matrix” stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely-varying extrinsic and intrinsic factors such as age, nutrition, exercise levels and biomechanics. Consequently, tendon adapts dynamically during development, ageing and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair. PMID:25640030

  10. Synthesis, development, characterization and effectiveness of bovine pure platelet gel-collagen-polydioxanone bioactive graft on tendon healing

    PubMed Central

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2015-01-01

    Bovine platelet gel (BPG) is an accessible and cost-effective source of growth factors which may have a value in tendon regenerative medicine. We produced a collagen implant (CI) as a tendon proper, covered it with polydioxanone (PDS) sheath to simulate paratenon and finally embedded the BPG as an active source of growth factor within the bioimplant to test whether BPG would be able to accelerate and enhance tendon regeneration and repair. After in vitro characterization of the bioactive grafts, the grafts were implanted in rabbit large tendon defect model. Untreated tendons and tendons treated with either CI or CI-PDS were served as controls for the CI-PDS-BPG. The animals were investigated clinically, ultrasonographically and haematologically for 120 days. After euthanasia, dry matter content, water uptake and delivery characteristics and also gross morphological, histopathological and scanning electron microscopic features of the healing tendons were assessed. In vitro, the activated platelets in the scaffold, released their growth factors significantly more than the controls. BPG also increased cell viability, and enhanced cellular differentiation, maturation and proliferation inside the CI-PDS compared with the controls. In vivo, the BPG modulated inflammation, increased quality and rate of fibroplasia and produced a remodelled tendon that had significantly higher collagen content and superior collagen fibril and fibre differentiation than controls. Treatment also significantly improved tendon water uptake and delivery characteristics, animals’ serum PDGF level, CI-PDS biocompatibility and biodegradability and reduced peritendinous adhesions, muscle fibrosis and atrophy. BPG was effective on tendon healing and CI-PDS-BPG may be a valuable bioscaffold in tendon reconstructive surgery. PMID:25702535

  11. The paratenon contributes to scleraxis-expressing cells during patellar tendon healing.

    PubMed

    Dyment, Nathaniel A; Liu, Chia-Feng; Kazemi, Namdar; Aschbacher-Smith, Lindsey E; Kenter, Keith; Breidenbach, Andrew P; Shearn, Jason T; Wylie, Christopher; Rowe, David W; Butler, David L

    2013-01-01

    The origin of cells that contribute to tendon healing, specifically extrinsic epitenon/paratenon cells vs. internal tendon fibroblasts, is still debated. The purpose of this study is to determine the location and phenotype of cells that contribute to healing of a central patellar tendon defect injury in the mouse. Normal adult patellar tendon consists of scleraxis-expressing (Scx) tendon fibroblasts situated among aligned collagen fibrils. The tendon body is surrounded by paratenon, which consists of a thin layer of cells that do not express Scx and collagen fibers oriented circumferentially around the tendon. At 3 days following injury, the paratenon thickens as cells within the paratenon proliferate and begin producing tenascin-C and fibromodulin. These cells migrate toward the defect site and express scleraxis and smooth muscle actin alpha by day 7. The thickened paratenon tissue eventually bridges the tendon defect by day 14. Similarly, cells within the periphery of the adjacent tendon struts express these markers and become disorganized. Cells within the defect region show increased expression of fibrillar collagens (Col1a1 and Col3a1) but decreased expression of tenogenic transcription factors (scleraxis and mohawk homeobox) and collagen assembly genes (fibromodulin and decorin). By contrast, early growth response 1 and 2 are upregulated in these tissues along with tenascin-C. These results suggest that paratenon cells, which normally do not express Scx, respond to injury by turning on Scx and assembling matrix to bridge the defect. Future studies are needed to determine the signaling pathways that drive these cells and whether they are capable of producing a functional tendon matrix. Understanding this process may guide tissue engineering strategies in the future by stimulating these cells to improve tendon repair.

  12. Evaluating adhesion reduction efficacy of type I/III collagen membrane and collagen-GAG resorbable matrix in primary flexor tendon repair in a chicken model.

    PubMed

    Turner, John B; Corazzini, Rubina L; Butler, Timothy J; Garlick, David S; Rinker, Brian D

    2015-09-01

    Reduction of peritendinous adhesions after injury and repair has been the subject of extensive prior investigation. The application of a circumferential barrier at the repair site may limit the quantity of peritendinous adhesions while preserving the tendon's innate ability to heal. The authors compare the effectiveness of a type I/III collagen membrane and a collagen-glycosaminoglycan (GAG) resorbable matrix in reducing tendon adhesions in an experimental chicken model of a "zone II" tendon laceration and repair. In Leghorn chickens, flexor tendons were sharply divided using a scalpel and underwent repair in a standard fashion (54 total repairs). The sites were treated with a type I/III collagen membrane, collagen-GAG resorbable matrix, or saline in a randomized fashion. After 3 weeks, qualitative and semiquantitative histological analysis was performed to evaluate the "extent of peritendinous adhesions" and "nature of tendon healing." The data was evaluated with chi-square analysis and unpaired Student's t test. For both collagen materials, there was a statistically significant improvement in the degree of both extent of peritendinous adhesions and nature of tendon healing relative to the control group. There was no significant difference seen between the two materials. There was one tendon rupture observed in each treatment group. Surgical handling characteristics were subjectively favored for type I/III collagen membrane over the collagen-GAG resorbable matrix. The ideal method of reducing clinically significant tendon adhesions after injury remains elusive. Both materials in this study demonstrate promise in reducing tendon adhesions after flexor tendon repair without impeding tendon healing in this model.

  13. The Coracohumeral Distance in Shoulders With Traumatic and Degenerative Subscapularis Tendon Tears.

    PubMed

    Balke, Maurice; Banerjee, Marc; Greshake, Oliver; Hoeher, Juergen; Bouillon, Bertil; Liem, Dennis

    2016-01-01

    A reduced coracohumeral distance (CHD) is thought to be responsible for subcoracoid impingement. This only accounts for degenerative tendon tears. In traumatic tears, the subcoracoid space should be normal. The CHD in patients with traumatic subscapularis tendon tears is larger than that in patients with degenerative tears and does not differ from patients with an intact subscapularis tendon. Cohort study; Level of evidence, 3. A total of 83 patients with arthroscopically certified subscapularis tendon tears were included in the study. Forty-four patients had degenerative causes (group 1), and 39 had traumatic causes (group 2). The control group consisted of 20 patients with traumatic supraspinatus tendon tears and arthroscopically proven, intact subscapularis tendons (group 3). On preoperative axial magnetic resonance imaging, the distance between the CHD was measured, and the values of the 3 groups were compared using the t test. The mean (±SD) CHD in patients with degenerative subscapularis tendon tears was 8.6 ± 2.0 mm (range, 4.0-13.2 mm) and was significantly (P = .0003) smaller than that in patients with traumatic tears (10.2 ± 2.0 mm; range, 6.6-16.2 mm) or controls (10.4 ± 1.8 mm; range, 6.8-14.0 mm). The CHD of controls and patients with traumatic tears did not differ significantly (P = .7875). A CHD of less than 6 mm only occurred in patients with degenerative subscapularis tendon tears. The hypothesis that the CHD in patients with degenerative subscapularis tendon tears is significantly smaller than that in patients with traumatic tears or intact subscapularis tendons was confirmed. The CHD in patients with traumatic tears does not differ from that in controls. A CHD of less than 6 mm only occurs in patients with degenerative subscapularis tendon tears. © 2015 The Author(s).

  14. Nonsurgical treatment and early return to activity leads to improved Achilles tendon fatigue mechanics and functional outcomes during early healing in an animal model.

    PubMed

    Freedman, Benjamin R; Gordon, Joshua A; Bhatt, Pankti R; Pardes, Adam M; Thomas, Stephen J; Sarver, Joseph J; Riggin, Corinne N; Tucker, Jennica J; Williams, Alexis W; Zanes, Robert C; Hast, Michael W; Farber, Daniel C; Silbernagel, Karin G; Soslowsky, Louis J

    2016-12-01

    Achilles tendon ruptures are common and devastating injuries; however, an optimized treatment and rehabilitation protocol has yet to be defined. Therefore, the objective of this study was to investigate the effects of surgical repair and return to activity on joint function and Achilles tendon properties after 3 weeks of healing. Sprague-Dawley rats (N = 100) received unilateral blunt transection of their Achilles tendon. Animals were then randomized into repaired or non-repaired treatments, and further randomized into groups that returned to activity after 1 week (RTA1) or after 3 weeks (RTA3) of limb casting in plantarflexion. Limb function, passive joint mechanics, and tendon properties (mechanical, organizational using high frequency ultrasound, histological, and compositional) were evaluated. Results showed that both treatment and return to activity collectively affected limb function, passive joint mechanics, and tendon properties. Functionally, RTA1 animals had increased dorsiflexion ROM and weight bearing of the injured limb compared to RTA3 animals 3-weeks post-injury. Such functional improvements in RTA1 tendons were evidenced in their mechanical fatigue properties and increased cross sectional area compared to RTA3 tendons. When RTA1 was coupled with nonsurgical treatment, superior fatigue properties were achieved compared to repaired tendons. No differences in cell shape, cellularity, GAG, collagen type I, or TGF-β staining were identified between groups, but collagen type III was elevated in RTA3 repaired tendons. The larger tissue area and increased fatigue resistance created in RTA1 tendons may prove critical for optimized outcomes in early Achilles tendon healing following complete rupture. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2172-2180, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Faster Movement Speed Results in Greater Tendon Strain during the Loaded Squat Exercise

    PubMed Central

    Earp, Jacob E.; Newton, Robert U.; Cormie, Prue; Blazevich, Anthony J.

    2016-01-01

    Introduction: Tendon dynamics influence movement performance and provide the stimulus for long-term tendon adaptation. As tendon strain increases with load magnitude and decreases with loading rate, changes in movement speed during exercise should influence tendon strain. Methods: Ten resistance-trained men [squat one repetition maximum (1RM) to body mass ratio: 1.65 ± 0.12] performed parallel-depth back squat lifts with 60% of 1RM load at three different speeds: slow fixed-tempo (TS: 2-s eccentric, 1-s pause, 2-s concentric), volitional-speed without a pause (VS) and maximum-speed jump (JS). In each condition joint kinetics, quadriceps tendon length (LT), patellar tendon force (FT), and rate of force development (RFDT) were estimated using integrated ultrasonography, motion-capture, and force platform recordings. Results: Peak LT, FT, and RFDT were greater in JS than TS (p < 0.05), however no differences were observed between VS and TS. Thus, moving at faster speeds resulted in both greater tendon stress and strain despite an increased RFDT, as would be predicted of an elastic, but not a viscous, structure. Temporal comparisons showed that LT was greater in TS than JS during the early eccentric phase (10–14% movement duration) where peak RFDT occurred, demonstrating that the tendon's viscous properties predominated during initial eccentric loading. However, during the concentric phase (61–70 and 76–83% movement duration) differing FT and similar RFDT between conditions allowed for the tendon's elastic properties to predominate such that peak tendon strain was greater in JS than TS. Conclusions: Based on our current understanding, there may be an additional mechanical stimulus for tendon adaptation when performing large range-of-motion isoinertial exercises at faster movement speeds. PMID:27630574

  16. Nonsurgical treatment and early return to activity leads to improved Achilles tendon fatigue mechanics and functional outcomes during early healing in an animal model

    PubMed Central

    Freedman, BR; Gordon, JA; Bhatt, PB; Pardes, AM; Thomas, SJ; Sarver, JJ; Riggin, CN; Tucker, JJ; Williams, AW; Zanes, RC; Hast, MW; Farber, DC; Silbernagel, KG; Soslowsky, LJ

    2016-01-01

    Achilles tendon ruptures are common and devastating injuries; however, an optimized treatment and rehabilitation protocol has yet to be defined. Therefore, the objective of this study was to investigate the effects of surgical repair and return to activity on joint function and Achilles tendon properties after 3-weeks of healing. Sprague Dawley rats (N=100) received unilateral blunt transection of their Achilles tendon. Animals were then randomized into repaired or non-repaired treatments, and further randomized into groups that returned to activity after 1-week (RTA1) or after 3-weeks (RTA3) of limb casting in plantarflexion. Limb function, passive joint mechanics, and tendon properties (mechanical, organizational using high frequency ultrasound, histological, and compositional) were evaluated. Results showed that both treatment and return to activity collectively affected limb function, passive joint mechanics, and tendon properties. Functionally, RTA1 animals had increased dorsiflexion ROM and weight bearing of the injured limb compared to RTA3 animals 3-weeks post injury. Such functional improvements in RTA1 tendons were evidenced in their mechanical fatigue properties and increased cross sectional area compared to RTA3 tendons. When RTA1 was coupled with nonsurgical treatment, superior fatigue properties were achieved compared to repaired tendons. No differences in cell shape, cellularity, GAG, collagen type I, or TGF-β staining were identified between groups, but collagen type III was elevated in RTA3 repaired tendons. The larger tissue area and increased fatigue resistance created in RTA1 tendons may prove critical for optimized outcomes in early Achilles tendon healing following complete rupture. PMID:27038306

  17. The influence of freezing on the tensile strength of tendon grafts : a biomechanical study.

    PubMed

    Arnout, Nele; Myncke, Jan; Vanlauwe, Johan; Labey, Luc; Lismont, Daniel; Bellemans, Johan

    2013-08-01

    We investigated the influence of freezing on the tensile strength of fresh frozen tendon grafts. The biomechanical characteristics of tendons that are less commonly used in knee surgery (tibialis anterior, tibialis posterior, peroneus longus and medial and lateral half of Achilles tendons) were compared to those of a semitendinosus and gracilis graft harvested from the same 10 multi-organ donors. All right side tendons constituted the study group and were frozen at -80 degrees C and thawed at room temperature 5 times. All left side tendons were frozen at -80 degrees C and thawed at room temperature once. There were 59 tendons in the control group and 56 in the study group. The looped grafts were clamped at one side using a custom-made freeze clamp and loaded until failure on an Instron 4505 testing machine. The average ultimate failure load was not significantly different between the control and the study group (p > 0.05). The failure load of the medial tendon Achilles was the lowest in both study and control group (p < 0.001). There was no significant difference in maximum stress, maximum displacement, maximum strain and stiffness between the control and study group (p > 0.05). From our study, we conclude that freezing tendons at -80 degrees C and thawing several times does not influence the maximum load, maximum stress, maximum displacement, maximum strain and stiffness. The medial half of the Achilles tendon is clearly the weakest tendon (p < 0.001). These findings show that tendon grafts can be frozen at -80 degrees C and thawed at room temperature several times without altering their biomechanical properties.

  18. Minimally invasive reconstruction of chronic achilles tendon ruptures using the ipsilateral free semitendinosus tendon graft and interference screw fixation.

    PubMed

    Maffulli, Nicola; Loppini, Mattia; Longo, Umile Giuseppe; Maffulli, Gayle D; Denaro, Vincenzo

    2013-05-01

    Achilles tendon ruptures represent more than 40% of all tendon ruptures requiring surgical management. About 20% of acute Achilles tendon tears are not diagnosed at the time of injury and become chronic, necessitating more complicated management than fresh injuries. Several techniques for the reconstruction of chronic tears of the Achilles tendon have been described, but the superiority of one technique over the others has not been demonstrated. Mini-invasive reconstruction of the Achilles tendon, with a gap lesion larger than 6 cm, using the ipsilateral free semitendinosus tendon graft will result in improvement of the overall function with a low rate of complications. Case series; Level of evidence, 4. Between 2008 and 2010, the authors prospectively enrolled 28 consecutive patients (21 men and 7 women; median age, 46 years) with chronic closed ruptures of the Achilles tendon who had undergone reconstruction with a free semitendinosus tendon graft. They assessed the Achilles tendon Total Rupture Score (ATRS), maximum calf circumference, and isometric plantarflexion strength before surgery and at the last follow-up. Outcome of surgery and rate of complications were also recorded. The median follow-up after surgery was 31.4 months. The overall result of surgery was excellent/good in 26 (93%) of 28 patients. The ATRS improved from 42 (range, 29-55) to 86 (range, 78-95) (P < .0001). In the operated leg, the maximum calf circumference and isometric plantarflexion strength were significantly improved after surgery (P < .0001); however, their values remained significantly lower than those of the opposite side (P < .0001). All patients were able to walk on tiptoes and returned to their preinjury working occupation. No infections were recorded. Mini-invasive reconstruction of the Achilles tendon, with a gap lesion larger than 6 cm, using the ipsilateral free semitendinosus tendon graft provides a significant improvement of symptoms and function, although calf circumference and ankle plantarflexion strength do not recover fully.

  19. A novel remaining tendon preserving repair technique leads to improved outcomes in special rotator cuff tear patterns.

    PubMed

    Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin

    2018-05-16

    The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.

  20. An advanced glycation endproduct (AGE)-rich diet promotes accumulation of AGEs in Achilles tendon.

    PubMed

    Skovgaard, Dorthe; Svensson, Rene B; Scheijen, Jean; Eliasson, Pernilla; Mogensen, Pernille; Hag, Anne Mette F; Kjær, Michael; Schalkwijk, Casper G; Schjerling, Peter; Magnusson, Stig P; Couppé, Christian

    2017-03-01

    Advanced Glycation Endproducts (AGEs) accumulate in long-lived tissue proteins like collagen in bone and tendon causing modification of the biomechanical properties. This has been hypothesized to raise the risk of orthopedic injury such as bone fractures and tendon ruptures. We evaluated the relationship between AGE content in the diet and accumulation of AGEs in weight-bearing animal Achilles tendon. Two groups of mice (C57BL/6Ntac) were fed with either high-fat diet low in AGEs high-fat diet (HFD) ( n  = 14) or normal diet high in AGEs (ND) ( n  = 11). AGE content in ND was six to 50-fold higher than HFD The mice were sacrificed at week 40 and Achilles and tail tendons were carefully excised to compare weight and nonweight-bearing tendons. The amount of the AGEs carboxymethyllysine (CML), methylglyoxal-derived hydroimidazolone (MG-H1) and carboxyethyllysine (CEL) in Achilles and tail tendon was measured using ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) and pentosidine with high-pressure liquid chromatography (HPLC) with fluorescent detection. AGEs in Achilles tendon were higher than in tail tendon for CML ( P  < 0.0001), CEL ( P  < 0.0001), MG-H1 and pentosidine (for both ND and HFD) ( P  < 0.0001). The AGE-rich diet (ND) resulted in an increase in CML ( P  < 0.0001), MG-H1 ( P  < 0.001) and pentosidine ( P  < 0.0001) but not CEL, in Achilles and tail tendon. This is the first study to provide evidence for AGE accumulation in injury-prone, weight-bearing Achilles tendon associated with intake of an AGE-rich diet. This indicates that food-derived AGEs may alter tendon properties and the development of tendon injuries. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  1. Prevalence and Role of a Low-Lying Peroneus Brevis Muscle Belly in Patients With Peroneal Tendon Pathologic Features: A Potential Source of Tendon Subluxation.

    PubMed

    Mirmiran, Roya; Squire, Chad; Wassell, Daniel

    2015-01-01

    A peroneus brevis low-lying muscle belly (LLMB) is a rare anomaly. A few published studies have supported the presence of this anomaly as an etiology for a peroneal tendon tear. However, the association between a peroneus brevis LLMB and tendon subluxation has not been well explored. In the present retrospective study, the magnetic resonance imaging (MRI) and intraoperative findings of 50 consecutive patients undergoing primary peroneal tendon surgery during a 5-year period were assessed. The sensitivity and specificity of MRI compared with the intraoperative findings for identifying peroneal tendon disease were investigated. The presence of associated peroneal tendon pathologic features in patients with and without a peroneus brevis LLMB was also compared. The sensitivity of MRI was high for identifying peroneal tenosynovitis (81.58%) and tear (85.71%). Although the sensitivity of MRI for detecting a peroneus brevis LLMB (3.23%) and tendon subluxation (10.00%) was low, MRI had high specificity at 94.74% and 100%, respectively. Intraoperatively, a peroneus brevis LLMB was seen in 62.00% of the patients with chronic lateral ankle pain and was associated with 64.52% of the patients with tenosynovitis, 29.03% of those with tendon subluxation, and 80.65% of those with a peroneus brevis tendon tear. Although the presence of a peroneus brevis LLMB did not show any statistically significant association with peroneus brevis tendon subluxation, of the 10 patients with intraoperatively observed tendon subluxation, 9 had a concomitant peroneus brevis LLMB. More studies with larger patient populations are needed to better investigate the role of a peroneus brevis LLMB as a mass-occupying lesion resulting in peroneal tendon subluxation. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. The enthesis organ concept and its relevance to the spondyloarthropathies.

    PubMed

    Benjamin, Michael; McGonagle, Dennis

    2009-01-01

    A characteristic feature of the spondyloarthropathies is inflammation at tendon or ligament attachment sites. This has traditionally been viewed as a focal abnormality, even though the inflammatory reaction intrinsic to enthesitis may be quite extensive. We argue that the diffuse nature of the pathology is best understood in the context of an 'enthesis organ concept'. This highlights the fact that stress concentration at an insertion site involves not only the enthesis itself, but neighbouring tissues as well. The archetypal enthesis organ is that of the Achilles tendon where intermittent contact between tendon and bone immediately proximal to the enthesis leads to the formation of fibrocartilages on the deep surface of the tendon and on the opposing calcaneal tuberosity, but similar functional modifications are widespread throughout the skeleton. Many entheses have bursae and fat near the insertion site and both of these serve to promote frictionless movement. Collectively, the fibrocartilages, bursa, fat pad and the enthesis itself constitute the enthesis organ. However, it also includes both the immediately adjacent trabecular bone networks and in some cases deep fascia. The concept of a synovio-entheseal complex (SEC) and of a 'functional enthesis' are complimentary to that of an enthesis organ and also have important implications for understanding spondyloarthropathy. The SEC concept emphasizes the interdependence between synovial membrane and entheses within enthesis organs. It draws attention to the fact that one component (the enthesis) is prone to microdamage and the other (the synovium) to inflammation. If an enthesis is damaged, any ensuing inflammatory reaction is likely to occur in the synovium. The concept of a 'functional enthesis' serves to emphasise anatomical, biomechanical and pathological features that are shared between true fibrocartilaginous entheses and regions proximal to the attachment sites themselves where tendons or ligaments wrap around bony pulleys. Such'wrap-around regions' are well documented sites of pathology in SpA-for tenosynovitis is a recognized feature. Stress concentration at the enthesis itself is dissipated at many sites by fibrous connections between one tendon or ligament and another, close to the insertion site. At a microscopic level, enthesis fibrocartilage is of paramount importance in ensuring that fibre bending of the tendon or ligament is not focused at the hard tissue interface. Normal enthesis organs are avascular in their fibrocartilaginous regions, but tissue microdamage to entheses is common and appears to be associated with tissue repair responses and vessel ingrowth. This makes the enthesis organ a site where adjuvant molecules derived from bacteria may be preferentially deposited. This microdamage and propensity for bacterial molecule deposition in the context of genetic factors such as HLA-B27 appears to lead to the characteristic inflammatory changes of AS. Understanding the enthesis organ concept helps to explain synovitis and osteitis in spondyloarthropathy. An appreciation of the complex anatomy of 'articular enthesis organs' (e.g., that associated with the distal interphalangeal joints) is helpful in understanding disease patterns in psoriatic arthritis. In this chapter, we review the extent and types ofenthesis organs and show how a patho-anatomic appreciation of these structures leads to a new platform for understanding the pathogenesis of SpA.

  3. Reconstruction of a ruptured patellar tendon using ipsilateral semitendinosus and gracilis tendons with preserved distal insertions: two case reports

    PubMed Central

    2013-01-01

    Background Acute patellar tendon ruptures with poor tissue quality. Ruptures that have been neglected are difficult to repair. Several surgical techniques for the repair of the patellar tendon have been reported, however, these techniques remain difficult because of contractures, adhesions, and atrophy of the quadriceps muscle after surgery. Case presentation We report the cases of 2 Japanese patients (Case 1: a 16-year-old male and Case 2: a 43-year-old male) with patellar tendon ruptures who were treated by reconstruction using semitendinosus-gracilis (STG) tendons with preserved distal insertions. Retaining the original insertion of the STG appears to preserve its viability and provide the revascularization necessary to accelerate healing. Both tendons were placed in front of the patella, in a figure-of-eight fashion, providing stability to the patella. Conclusion Both patients recovered near normal strength and stability of the patellar tendon as well as restoration of function after the operation. PMID:24010848

  4. Increased muscle belly and tendon stiffness in patients with Parkinson's disease, as measured by myotonometry.

    PubMed

    Marusiak, Jarosław; Jaskólska, Anna; Budrewicz, Sławomir; Koszewicz, Magdalena; Jaskólski, Artur

    2011-09-01

    Based on Davis's law, greater tonus of the muscle belly in individuals with Parkinson's disease can create greater tension in the tendon, leading to structural adjustment and an increase in tendon stiffness. Our study aimed to separately assess passive stiffness in the muscle belly and tendon in medicated patients with Parkinson's disease, using myotonometry. We tested 12 patients with Parkinson's disease and 12 healthy matched controls. Passive stiffness of muscle belly and tendon was estimated by myotonometry, electromyography, and mechanomyography in relaxed biceps and triceps brachii muscles. Compared with controls, patients with Parkinson's disease had higher stiffness in the muscle belly and tendon of the biceps brachii and in the tendon of the triceps brachii. In patients with Parkinson's disease, there was a positive correlation between muscle belly stiffness and parkinsonian rigidity in the biceps brachii. Patients with Parkinson's disease have higher passive stiffness of the muscle belly and tendon than healthy matched controls. Copyright © 2011 Movement Disorder Society.

  5. Magnetic resonance imaging of the long head of the biceps tendon: benefit of coplanar image.

    PubMed

    Lin, Anderson; Ting, Julius; Lee, Kwo-Whei

    2007-01-01

    To evaluate coplanar imaging of the long head of the biceps tendon. We retrospectively compared coronal oblique magnetic resonance images aligned with the principal supraspinatus tendon and with the intra-articular biceps tendon in 21 patients. Magnetic resonance images were analyzed for lesions depicted, including superior labral anteroposterior (SLAP) tears. Arthroscopic findings were reviewed. Coronal oblique images aligned with intra-articular biceps tendon depicted 18 (86%) of 21 coplanar intra-articular biceps tendons. Coplanar images identified 6 cases of tendinosis, 1 tear, 3 intra-articular ruptures, and 20 (95.2%) of 21 exact origins of the tendon. Arthroscopy revealed 18 SLAP tears. The detection of SLAP lesions between both coronal oblique magnetic resonance images was significantly different (P = 0.007). Advantages included imaging of the intra-articular biceps tendon with least partial-volume effects, definition of SLAP lesions and the tendinous origin at the supraglenoid tubercle, depiction of intra-articular bicipital ruptures, and increased sensitivity and specificity for intra-articular lesions.

  6. New Imaging Methods for Non-invasive Assessment of Mechanical, Structural, and Biochemical Properties of Human Achilles Tendon: A Mini Review

    PubMed Central

    Fouré, Alexandre

    2016-01-01

    The mechanical properties of tendon play a fundamental role to passively transmit forces from muscle to bone, withstand sudden stretches, and act as a mechanical buffer allowing the muscle to work more efficiently. The use of non-invasive imaging methods for the assessment of human tendon's mechanical, structural, and biochemical properties in vivo is relatively young in sports medicine, clinical practice, and basic science. Non-invasive assessment of the tendon properties may enhance the diagnosis of tendon injury and the characterization of recovery treatments. While ultrasonographic imaging is the most popular tool to assess the tendon's structural and indirectly, mechanical properties, ultrasonographic elastography, and ultra-high field magnetic resonance imaging (UHF MRI) have recently emerged as potentially powerful techniques to explore tendon tissues. This paper highlights some methodological cautions associated with conventional ultrasonography and perspectives for in vivo human Achilles tendon assessment using ultrasonographic elastography and UHF MRI. PMID:27512376

  7. IN VIVO MEASURES OF SHEAR WAVE SPEED AS A PREDICTOR OF TENDON ELASTICITY AND STRENGTH

    PubMed Central

    Martin, Jack A.; Biedrzycki, Adam H.; Lee, Kenneth S.; DeWall, Ryan J.; Brounts, Sabrina H.; Murphy, William L.; Markel, Mark D.; Thelen, Darryl G.

    2015-01-01

    The purpose of this study was to assess the potential for ultrasound shear wave elastography (SWE) to assess tissue elasticity and ultimate stress in both intact and healing tendons. The lateral gastrocnemius (Achilles) tendons of 41 New Zealand white rabbits were surgically severed and repaired with growth factor coated sutures. SWE imaging was used to measure shear wave speed (SWS) in both the medial and lateral tendons pre-surgery, and at 2 and 4 weeks post-surgery. Rabbits were euthanized at 4 weeks, and both medial and lateral tendons underwent mechanical testing to failure. SWS significantly (p<0.001) decreased an average of 17% between the intact and post-surgical state across all tendons. SWS was significantly (p<0.001) correlated with both the tendon elastic modulus (r = 0.52) and ultimate stress (r = 0.58). Thus, ultrasound SWE is a potentially promising noninvasive technology for quantitatively assessing the mechanical integrity of pre-operative and post-operative tendons. PMID:26215492

  8. An overview of structure, mechanical properties, and treatment for age-related tendinopathy.

    PubMed

    Zhou, B; Zhou, Y; Tang, K

    2014-04-01

    Tendons transfer tensile loads from muscle to bone, which enable joint motions and stabilize joints. Tendons sustain large mechanical loads in vivo and as a result, tendons were frequently injured. Aging has been confirmed as a predisposing factor of tendinopathy and bad recovery quality following tendon repair. Current treatment methods are generally not effective and involve either symptomatic relief with non-steroidal antiinflammatory drugs and physical therapy or surgery when conservative treatments failed. The limitation in treatment options is due to our incomplete knowledge of age-related tendinopathy. Studies over the past decades have uncovered a number of important mechanical and cellular changes of aging tendon. However, the basis of aging as a major risk factor for tendon injury and impaired tendon healing remained poorly understood. The objectives of this review are to provide an overview of the current knowledge about the aging-associated changes of structure, mechanical properties and treatment in tendon and highlight causes and therapies for age-related tendinopathy.

  9. National Rugby League athletes and tendon tap reflex assessment: a matched cohort clinical study.

    PubMed

    Maurini, James; Ohmsen, Paul; Condon, Greg; Pope, Rodney; Hing, Wayne

    2016-11-04

    Limited research suggests elite athletes may differ from non-athletes in clinical tendon tap reflex responses. In this matched cohort study, 25 elite rugby league athletes were compared with 29 non-athletes to examine differences in tendon reflex responses. Relationships between reflex responses and lengths of players' careers were also examined. Biceps, triceps, patellar and Achilles tendon reflexes were clinically assessed. Right and left reflexes were well correlated for each tendon (r S  = 0.7-0.9). The elite rugby league athletes exhibited significantly weaker reflex responses than non-athletes in all four tendons (p < 0.005). Biceps reflexes demonstrated the largest difference and Achilles reflexes the smallest difference. Moderate negative correlations (r S  = -0.3-0.6) were observed between reflex responses and lengths of players' careers. Future research is required to further elucidate mechanisms resulting in the observed differences in tendon reflexes and to ensure clinical tendon tap examinations and findings can be interpreted appropriately in this athletic population.

  10. Data-driven methods towards learning the highly nonlinear inverse kinematics of tendon-driven surgical manipulators.

    PubMed

    Xu, Wenjun; Chen, Jie; Lau, Henry Y K; Ren, Hongliang

    2017-09-01

    Accurate motion control of flexible surgical manipulators is crucial in tissue manipulation tasks. The tendon-driven serpentine manipulator (TSM) is one of the most widely adopted flexible mechanisms in minimally invasive surgery because of its enhanced maneuverability in torturous environments. TSM, however, exhibits high nonlinearities and conventional analytical kinematics model is insufficient to achieve high accuracy. To account for the system nonlinearities, we applied a data driven approach to encode the system inverse kinematics. Three regression methods: extreme learning machine (ELM), Gaussian mixture regression (GMR) and K-nearest neighbors regression (KNNR) were implemented to learn a nonlinear mapping from the robot 3D position states to the control inputs. The performance of the three algorithms was evaluated both in simulation and physical trajectory tracking experiments. KNNR performed the best in the tracking experiments, with the lowest RMSE of 2.1275 mm. The proposed inverse kinematics learning methods provide an alternative and efficient way to accurately model the tendon driven flexible manipulator. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Real-time sonoelastography as novel follow-up method in Achilles tendon surgery.

    PubMed

    Busilacchi, A; Olivieri, M; Ulisse, S; Gesuita, R; Skrami, E; Lording, T; Fusini, F; Gigante, A

    2016-07-01

    To evaluate the sonoelastographic features of Achilles tendon healing after percutaneous treatment using real-time sonoelastography, a new tool able to quantify deformation in biological tissues. Patients with atraumatic Achilles tendon ruptures, treated with a percutaneous technique, were assessed. Sonoelastographic evaluations were performed at the myotendinous junction, tendon body/lesion site and osteotendinous junction, both for the operated and contralateral side, at 40 days, 6 months and 1 year after surgery. Using standard regions of interest, the "strain index" (SI) was calculated as an indicator of tendon elasticity. Clinical outcomes were assessed by the ATRS questionnaire at 6 months and 1 year post-operatively and correlated with sonoelastographic findings. Sixty healthy tendons from 30 volunteers were used to provide a healthy control range. Twenty-five patients were recruited for this study. The SI in treated tendons showed progressive stiffening over time, especially at myotendinous junction and at the site of the sutured lesion, resulting in significantly higher stiffness than both the contralateral tendon and healthy volunteers. Peak thickness of treated tendons occurred at 6 months, with a tendency to reduce at 1 year, while never achieving a normal physiological state. Greatest remodelling was seen at the lesion site. The contralateral tendon showed significant thickening at the myotendinous and osteotendinous junctions. The SI of the contralateral tendon was found to be stiffer than physiological values found in the control group. ATRS score improved significantly between 6 months and 1 year, being negatively correlated with the SI (p < 0.001). RTSE showed that operatively treated Achilles tendons become progressively stiffer during follow-up, while the ATRS score improved. From a biomechanical point of view, at 1 year after surgery Achilles tendons did not show a "restitutio ad integrum". Real-time sonoelastography provides more qualitative and quantitative details in the diagnostics and follow-up of Achilles tendon conditions as the post-operative evolution of the repairing tissue. Diagnostic and therapeutic study, Level III.

  12. Accumulation of Oxidized LDL in the Tendon Tissues of C57BL/6 or Apolipoprotein E Knock-Out Mice That Consume a High Fat Diet: Potential Impact on Tendon Health

    PubMed Central

    Grewal, Navdeep; Thornton, Gail M.; Behzad, Hayedeh; Sharma, Aishwariya; Lu, Alex; Zhang, Peng; Reid, W. Darlene; Granville, David J.; Scott, Alex

    2014-01-01

    Objective Clinical studies have suggested an association between dyslipidemia and tendon injuries or chronic tendon pain; the mechanisms underlying this association are not yet known. The objectives of this study were (1) to evaluate the impact of a high fat diet on the function of load-bearing tendons and on the distribution in tendons of oxidized low density lipoprotein (oxLDL), and (2) to examine the effect of oxLDL on tendon fibroblast proliferation and gene expression. Methods Gene expression (Mmp2, Tgfb1, Col1a1, Col3a1), fat content (Oil Red O staining), oxLDL levels (immunohistochemistry) and tendon biomechanical properties were examined in mice (C57Bl/6 or ApoE -/-) receiving a standard or a high fat diet. Human tendon fibroblast proliferation and gene expression (COL1A1, COL3A1, MMP2) were examined following oxLDL exposure. Results In both types of mice (C57Bl/6 or ApoE -/-), consumption of a high fat diet led to a marked increase in oxLDL deposition in the load-bearing extracellular matrix of the tendon. The consumption of a high fat diet also reduced the failure stress and load of the patellar tendon in both mouse types, and increased Mmp2 expression. ApoE -/- mice exhibited more pronounced reductions in tendon function than wild-type mice, and decreased expression of Col1a1 compared to wild type mice. Human tendon fibroblasts responded to oxLDL by increasing their proliferation and their mRNA levels of MMP2, while decreasing their mRNA levels for COL1A1 and COL3A1. Conclusion The consumption of a high fat diet resulted in deleterious changes in tendon function, and these changes may be explained in part by the effects of oxLDL, which induced a proliferative, matrix-degrading phenotype in human tenocytes. PMID:25502628

  13. Asymptomatic Achilles tendon pathology is associated with a central fat distribution in men and a peripheral fat distribution in women: a cross sectional study of 298 individuals

    PubMed Central

    2010-01-01

    Background Adiposity is a modifiable factor that has been implicated in tendinopathy. As tendon pain reduces physical activity levels and can lead to weight gain, associations between tendon pathology and adiposity must be studied in individuals without tendon pain. Therefore, the purpose of this study was to determine whether fat distribution was associated with asymptomatic Achilles tendon pathology. Methods The Achilles tendons of 298 individuals were categorised as normal or pathological using diagnostic ultrasound. Fat distribution was determined using anthropometry (waist circumference, waist hip ratio [WHR]) and dual-energy x-ray absorptiometry. Results Asymptomatic Achilles tendon pathology was more evident in men (13%) than women (5%) (p = 0.007). Men with tendon pathology were older (50.9 ± 10.4, 36.3 ± 11.3, p < 0.001), had greater WHR (0.926 ± 0.091, 0.875 ± 0.065, p = 0.039), higher android/gynoid fat mass ratio (0.616 ± 0.186, 0.519 ± 0.142, p = 0.014) and higher upper-body/lower body fat mass ratio (2.346 ± 0.630, 2.022 ± 0.467, p = 0.013). Men older than 40 years with a waist circumference >83 cm had the greatest prevalence of tendon pathology (33%). Women with tendon pathology were older (47.4 ± 10.0, 36.0 ± 10.3, p = 0.008), had less total fat (17196 ± 3173 g, 21626 ± 7882 g, p = 0.009), trunk fat (7367 ± 1662 g, 10087 ± 4152 g, p = 0.003) and android fat (1117 ± 324 g, 1616 ± 811 g, p = 0.005). They had lower central/peripheral fat mass ratios (0.711 ± 0.321 g, 0.922 ± 0.194 g, p = 0.004) than women with normal tendons. Women with tendon pathology were more often menopausal (63%, 13%, p = 0.002). Conclusions Men with Achilles tendon pathology were older and had a central fat distribution. Women with tendon pathology were older and had a peripheral fat distribution. An interaction between age and waist circumference was observed among men. PMID:20196870

  14. Direct Lentiviral-Cyclooxygenase 2 Application to the Tendon-Bone Interface Promotes Osteointegration and Enhances Return of the Pull-Out Tensile Strength of the Tendon Graft in a Rat Model of Biceps Tenodesis

    PubMed Central

    Wergedal, Jon E.; Stiffel, Virginia; Lau, Kin-Hing William

    2014-01-01

    This study sought to determine if direct application of the lentiviral (LV)-cyclooxygenase 2 (COX2) vector to the tendon-bone interface would promote osteointegration of the tendon graft in a rat model of biceps tenodesis. The LV-COX2 gene transfer strategy was chosen for investigation because a similar COX2 gene transfer strategy promoted bony bridging of the fracture gap during bone repair, which involves similar histologic transitions that occur in osteointegration. Briefly, a 1.14-mm diameter tunnel was drilled in the mid-groove of the humerus of adult Fischer 344 rats. The LV-COX2 or βgal control vector was applied directly into the bone tunnel and onto the end of the tendon graft, which was then pulled into the bone tunnel. A poly-L-lactide pin was press-fitted into the tunnel as interference fixation. Animals were sacrificed at 3, 5, or 8 weeks for histology analysis of osteointegration. The LV-COX2 gene transfer strategy enhanced neo-chondrogenesis at the tendon-bone interface but with only marginal effect on de novo bone formation. The tendon-bone interface of the LV-COX2-treated tenodesis showed the well-defined tendon-to-fibrocartilage-to-bone histologic transitions that are indicative of osteointegration of the tendon graft. The LV-COX2 in vivo gene transfer strategy also significantly enhanced angiogenesis at the tendon-bone interface. To determine if the increased osteointegration was translated into an improved pull-out mechanical strength property, the pull-out tensile strength of the LV-COX2-treated tendon grafts was determined with a pull-out mechanical testing assay. The LV-COX2 strategy yielded a significant improvement in the return of the pull-out strength of the tendon graft after 8 weeks. In conclusion, the COX2-based in vivo gene transfer strategy enhanced angiogenesis, osteointegration and improved return of the pull-out strength of the tendon graft. Thus, this strategy has great potential to be developed into an effective therapy to promote tendon-to-bone healing after tenodesis or related surgeries. PMID:24848992

  15. Inducement of semitendinosus tendon regeneration to the pes anserinus after its harvest for anterior cruciate ligament reconstruction-A new inducer grafting technique

    PubMed Central

    2012-01-01

    Purpose To investigate the usefulness of the “inducer grafting” technique for regeneration of the semitendinosus (ST) tendon after its harvest for anterior cruciate ligament (ACL) reconstruction. Methods Twenty knees of 20 patients (mean age at the time of surgery, 23.1 years) underwent ACL reconstruction with a double bundle autograft using the ST tendon (7 patients) and the ST + the gracilis (G) tendons (13 patients). “Inducer grafting” technique After harvesting the ST tendon, a passing pin with a loop thread is inserted along with the tendon stripper. The passing pin is pulled out from the medial thigh and the loop thread retained. As an inducer graft, the ST tendon branch is used. After the ACL graft has been secured, the inducer graft is sutured to the pes anserinus and the proximal end passed through by pulling the thread out. Then the inducer graft is placed within the tendon canal. The mean follow-up period was 15 months. The presence and morphology of the regenerated ST tendon were examined by MRI. And the isometric hamstring strength was examined at 45°, 90° and 120° of knee flexion. Results One month after the operation in all the patients, MRI demonstrated a low-intensity structure at the anatomical location of the ST, at the level of the superior pole of the patella and the joint line, apparently representing the regenerated ST tendon. Four months after the operation, the distal portion of the regenerated ST tendon had reached the pes anserinus in all patients. Twelve months after the operation, the regenerated ST tendon was hypertrophic in 19 of the 20 patients (95%). The isometric knee flexion torque of the ACL-reconstructed limb was significantly lower at 90° and 120° compared with the contralateral limb. Conclusion These results suggest that the “inducer grafting” technique is able to improve the regeneration rate of the harvested ST tendon and promote hypertrophy of the regenerated ST tendon, extending all the way to the pes anserinus. However, this technique couldn’t improve the deficits in knee flexion torque after ACL reconstruction. PMID:22607724

  16. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    PubMed

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  17. Tension Regulation at the Suture Lines for Repair of Neglected Achilles Tendon Laceration.

    PubMed

    Massoud, Elsayed Ibraheem Elsayed

    2017-03-01

    Operative intervention is the preferred option for management of the neglected laceration of the Achilles tendon. However, the commonly used techniques rarely follow the principles of the regenerative medicine for the restoration of the lost tissue. This study postulated that incorporation of the autogenous tendon graft would properly progress when the interplay between mechanical loading and healing phases was correctly applied. A prospective study included 15 patients who were treated for neglected Achilles tendon laceration using the technique of lengthening of the proximal tendon stump. An absorbable reinforcement suture was used for control of the mechanical environment at the suture lines. By an average 5 years of the prospective follow-up, all the repaired tendons had restored continuity and length. The calf circumference equalized to the uninjured side in 12 patients. However, 3 patients had calf atrophy but they improved compared to the preoperative measurements. Sonogram confirmed the restoration of the normal thickness and the gliding characteristics of the repaired tendon. The technique restored continuity and tension of the repaired tendon, preserved the calf circumference, and prevented peritendinous adhesions. The absorbable reinforcement suture spontaneously allowed for the mechanical loading of the grafted tendon. Level IV, case series.

  18. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture.

    PubMed

    Cetinkaya, Engin; Aydin, Canan Gonen; Akman, Yunus Emre; Gul, Murat; Arikan, Yavuz; Aycan, Osman Emre; Kabukcuoglu, Yavuz Selim

    2015-01-01

    Quadriceps tendon injuries are rare. There is a limited number of studies in the literature, reporting partial quadriceps tendon ruptures. We did not find any study reporting an isolated vastus intermedius tendon injury in the literature. A 22 years old professional rugby player with the complaints of pain in the right lower limb, decreased range of motion in right knee and a mass in the mid-anterior of the right thigh applied following an overloading on his hyperflexed knee during a rugby match. T2 sequence magnetic resonance images revealed discontinuity in the vastus intermedius tendon and intramuscular hematoma. The patient has been conservatively treated. Quadriceps tendon ruptures generally occur after the 4th decade in the presence of degenerative changes. Our case is a young professional rugby player. Isolated vastus intermedius tendon rupture is unusual. Conservative treatment is performed as the intermedius tendon is in the deepest layer of the quadriceps muscle. We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture

    PubMed Central

    Cetinkaya, Engin; Aydin, Canan Gonen; Akman, Yunus Emre; Gul, Murat; Arikan, Yavuz; Aycan, Osman Emre; Kabukcuoglu, Yavuz Selim

    2015-01-01

    Introduction Quadriceps tendon injuries are rare. There is a limited number of studies in the literature, reporting partial quadriceps tendon ruptures. We did not find any study reporting an isolated vastus intermedius tendon injury in the literature. Presentation of case A 22 years old professional rugby player with the complaints of pain in the right lower limb, decreased range of motion in right knee and a mass in the mid-anterior of the right thigh applied following an overloading on his hyperflexed knee during a rugby match. T2 sequence magnetic resonance images revealed discontinuity in the vastus intermedius tendon and intramuscular hematoma. The patient has been conservatively treated. Discussion Quadriceps tendon ruptures generally occur after the 4th decade in the presence of degenerative changes. Our case is a young professional rugby player. Isolated vastus intermedius tendon rupture is unusual. Conservative treatment is performed as the intermedius tendon is in the deepest layer of the quadriceps muscle. Conclusion We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy. PMID:26298093

  20. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair.

    PubMed

    Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2010-12-01

    Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P < .05) than that of torn tendons (1086 ± 388 N-mm and 177 ± 71 N, respectively). For medial suture placement, maximum load, stiffness, and work of intact and torn tendons were similar (P > .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P < .05). Superior pullout resistance of medially placed sutures may provide a strain shielding effect for the lateral row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to suture migration. While clinical factors such as musculotendinous integrity warrant strong consideration for surgical decision making, the present ultrastructural and biomechanical results appear to provide a scientific rationale for double-row rotator cuff repair where sutures are placed more medially at the muscle-tendon junction.

  1. Achilles Pain.

    ERIC Educational Resources Information Center

    Connors, G. Patrick

    Five ailments which can cause pain in the achilles tendon area are: (1) muscular strain, involving the stretching or tearing of muscle or tendon fibers; (2) a contusion, inflammation or infection called tenosynovitis; (3) tendonitis, the inflammation of the tendon; (4) calcaneal bursitis, the inflammation of the bursa between the achilles tendon…

  2. The Tendon Structure Returns to Asymptomatic Values in Nonoperatively Treated Achilles Tendinopathy but Is Not Associated With Symptoms: A Prospective Study.

    PubMed

    de Jonge, Suzan; Tol, Johannes L; Weir, Adam; Waarsing, Jan H; Verhaar, Jan A N; de Vos, Robert-Jan

    2015-12-01

    Tendinopathy is characterized by alterations in the tendon structure, but there are conflicting results on the potential of tendon structure normalization and no large studies on the quantified, ultrasonographic tendon structure and its association with symptoms. To determine whether the tendon structure returns to values of asymptomatic individuals after treatment with 2 substances injected within the tendon, to assess the association between the tendon structure and symptoms, and to assess the prognostic value of the baseline tendon structure on treatment response. Cohort study; Level of evidence, 2. This study was part of a randomized trial on chronic midportion Achilles tendinopathy using eccentric exercises with either a platelet-rich plasma or saline injection. Symptoms were recorded using the Victorian Institute of Sports Assessment-Achilles (VISA-A) questionnaire. The tendon structure was quantified with ultrasound tissue characterization (UTC); echo types I + II (as a percentage of total tendon types I-IV) are structure related. Follow-up was at 6, 12, 24, and 52 weeks. A control group of asymptomatic subjects (similar age) was selected to compare the tendon structure. Patient symptoms were correlated with the tendon structure using a linear model. Fifty-four patients were included in the symptomatic group. The mean (± SD) echo types I + II in the symptomatic group increased significantly from 74.6% ± 10.8% at baseline to 85.6% ± 6.0% at 24-week follow-up. The result for echo types I + II at 24 weeks was not significantly different (P = .198) from that of the asymptomatic control group (87.5% ± 6.0%). In 54 repeated measurements at 5 time points, the adjusted percentage of echo types I + II was not associated with the VISA-A score (main effect: β = .12; 95% CI, -0.12 to 0.35; P = .338). The adjusted baseline echo types I + II were not associated with a change in the VISA-A score from baseline to 52 weeks (β = -.15; 95% CI, -0.67 to 0.36; P = .555). In symptomatic, tendinopathic Achilles tendons, the ultrasonographic tendon structure improved during nonoperative treatment and normalized after 24 weeks to values of matched asymptomatic controls. There was no association between the tendon structure and symptoms. The percentage of echo types I + II before treatment was not associated with change in symptoms over time. This study demonstrates that restoration of the tendon structure is not required for an improvement of symptoms. © 2015 The Author(s).

  3. Muscle-tendon glucose uptake in Achilles tendon rupture and tendinopathy before and after eccentric rehabilitation: Comparative case reports.

    PubMed

    Masood, Tahir; Kalliokoski, Kari; Bojsen-Møller, Jens; Finni, Taija

    2016-09-01

    Achilles tendon rupture (ATR) is the most common tendon rupture injury. The consequences of ATR on metabolic activity of the Achilles tendon and ankle plantarflexors are unknown. Furthermore, the effects of eccentric rehabilitation on metabolic activity patterns of Achilles tendon and ankle plantarflexors in ATR patients have not been reported thus far. We present a case study demonstrating glucose uptake (GU) in the Achilles tendon, the triceps surae, and the flexor hallucis longus of a post-surgical ATR patient before and after a 5-month eccentric rehabilitation. At baseline, three months post-surgery, all muscles and Achilles tendon displayed much higher GU in the ATR patient compared to a healthy individual despite lower plantarflexion force. After the rehabilitation, plantarflexion force increased in the operated leg while muscle GU was considerably reduced. The triceps surae muscles showed similar values to the healthy control. When compared to the healthy or a matched patient with Achilles tendon pain after 12 weeks of rehabilitation, Achilles tendon GU levels of ATR patient remained greater after the rehabilitation. Past studies have shown a shift in the metabolic fuel utilization towards glycolysis due to immobilization. Further research, combined with immuno-histological investigation, is needed to fully understand the mechanism behind excessive glucose uptake in ATR cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Enhancing the Biomechanical Performance of Anisotropic Nanofibrous Scaffolds in Tendon Tissue Engineering: Reinforcement with Cellulose Nanocrystals.

    PubMed

    Domingues, Rui M A; Chiera, Silvia; Gershovich, Pavel; Motta, Antonella; Reis, Rui L; Gomes, Manuela E

    2016-06-01

    Anisotropically aligned electrospun nanofibrous scaffolds based on natural/synthetic polymer blends have been established as a reasonable compromise between biological and biomechanical performance for tendon tissue engineering (TE) strategies. However, the limited tensile properties of these biomaterials restrict their application in this field due to the load-bearing nature of tendon/ligament tissues. Herein, the use of cellulose nanocrystals (CNCs) as reinforcing nanofillers in aligned electrospun scaffolds based on a natural/synthetic polymer blend matrix, poly-ε-caprolactone/chitosan (PCL/CHT) is reported. The incorporation of small amounts of CNCs (up to 3 wt%) into tendon mimetic nanofiber bundles has a remarkable biomaterial-toughing effect (85% ± 5%, p < 0.0002) and raises the scaffolds mechanical properties to tendon/ligament relevant range (σ = 39.3 ± 1.9 MPa and E = 540.5 ± 83.7 MPa, p < 0.0001). Aligned PCL/CHT/CNC nanocomposite fibrous scaffolds meet not only the mechanical requirements for tendon TE applications but also provide tendon mimetic extracellular matrix (ECM) topographic cues, a key feature for maintaining tendon cell's morphology and behavior. The strategy proposed here may be extended to other anisotropic aligned nanofibrous scaffolds based on natural/synthetic polymer blends and enable the full exploitation of the advantages provided by their tendon mimetic fibrous structures in tendon TE. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Different Achilles Tendon Pathologies Show Distinct Histological and Molecular Characteristics

    PubMed Central

    Minkwitz, Susann; Schmock, Aysha; Bormann, Nicole; Kurtoglu, Alper; Tsitsilonis, Serafeim; Manegold, Sebastian

    2018-01-01

    Reasons for the development of chronic tendon pathologies are still under debate and more basic knowledge is needed about the different diseases. The aim of the present study was therefore to characterize different acute and chronic Achilles tendon disorders. Achilles tendon samples from patients with chronic tendinopathy (n = 7), chronic ruptures (n = 6), acute ruptures (n = 13), and intact tendons (n = 4) were analyzed. The histological score investigating pathological changes was significantly increased in tendinopathy and chronic ruptures compared to acute ruptures. Inflammatory infiltration was detected by immunohistochemistry in all tendon pathology groups, but was significantly lower in tendinopathy compared to chronic ruptures. Quantitative real-time PCR (qRT-PCR) analysis revealed significantly altered expression of genes related to collagens and matrix modeling/remodeling (matrix metalloproteinases, tissue inhibitors of metalloproteinases) in tendinopathy and chronic ruptures compared to intact tendons and/or acute ruptures. In all three tendon pathology groups markers of inflammation (interleukin (IL) 1β, tumor necrosis factor α, IL6, IL10, IL33, soluble ST2, transforming growth factor β1, cyclooxygenase 2), inflammatory cells (cluster of differentaition (CD) 3, CD68, CD80, CD206), fat metabolism (fatty acid binding protein 4, peroxisome proliferator-activated receptor γ, CCAAT/enhancer-binding protein α, adiponectin), and innervation (protein gene product 9.5, growth associated protein 43, macrophage migration inhibitory factor) were detectable, but only in acute ruptures significantly regulated compared to intact tendons. The study gives an insight into structural and molecular changes of pathological processes in tendons and might be used to identify targets for future therapy of tendon pathologies. PMID:29385715

  6. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons

    PubMed Central

    Thorpe, Chavaunne T.; Godinho, Marta S.C.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R.C.

    2015-01-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. PMID:25958330

  7. Manipulation of Foot Strike and Footwear Increases Achilles Tendon Loading During Running.

    PubMed

    Rice, Hannah; Patel, Mubarak

    2017-08-01

    The Achilles tendon is the most common site of tendon overuse injury in humans. Running with a forefoot strike pattern and in minimal shoes is a topic of recent interest, yet evidence is currently limited regarding the combined influence of foot strike and footwear on Achilles tendon loading. To investigate the influence of both foot strike and footwear on Achilles tendon loading in habitual rearfoot strike runners. Controlled laboratory study. Synchronized kinematic and force data were collected from 22 habitual rearfoot strikers (11 male), who habitually ran in nonminimal running shoes, during overground running at 3.6 m·s -1 . Participants ran in 3 different footwear conditions (standard running shoe, minimal running shoe, and barefoot) with both a rearfoot strike (RFS) and an imposed forefoot strike (FFS) in each footwear condition. Achilles tendon loading was estimated by use of inverse dynamics, where the Achilles tendon moment arm was determined with a regression equation. A 2-way, repeated-measures analysis of variance was used to compare conditions. Achilles tendon impulse was greater when subjects ran with an FFS rather than an RFS in minimal shoes. Achilles tendon loading rates were higher when subjects ran either in minimal shoes or barefoot than in standard shoes, regardless of foot strike. In runners who habitually rearfoot strike in standard running shoes, running in minimal shoes or barefoot increased the rate of tendon loading, and running with a forefoot strike in minimal shoes increased the magnitude of tendon loading. Transitioning to these running conditions may increase the risk of tendinopathy.

  8. Lack of tissue renewal in human adult Achilles tendon is revealed by nuclear bomb 14C

    PubMed Central

    Heinemeier, Katja Maria; Schjerling, Peter; Heinemeier, Jan; Magnusson, Stig Peter; Kjaer, Michael

    2013-01-01

    Tendons are often injured and heal poorly. Whether this is caused by a slow tissue turnover is unknown, since existing data provide diverging estimates of tendon protein half-life that range from 2 mo to 200 yr. With the purpose of determining life-long turnover of human tendon tissue, we used the 14C bomb-pulse method. This method takes advantage of the dramatic increase in atmospheric levels of 14C, produced by nuclear bomb tests in 1955–1963, which is reflected in all living organisms. Levels of 14C were measured in 28 forensic samples of Achilles tendon core and 4 skeletal muscle samples (donor birth years 1945–1983) with accelerator mass spectrometry (AMS) and compared to known atmospheric levels to estimate tissue turnover. We found that Achilles tendon tissue retained levels of 14C corresponding to atmospheric levels several decades before tissue sampling, demonstrating a very limited tissue turnover. The tendon concentrations of 14C approximately reflected the atmospheric levels present during the first 17 yr of life, indicating that the tendon core is formed during height growth and is essentially not renewed thereafter. In contrast, 14C levels in muscle indicated continuous turnover. Our observation provides a fundamental premise for understanding tendon function and pathology, and likely explains the poor regenerative capacity of tendon tissue.—Heinemeier, K. M., Schjerling, P., Heinemeier, J., Magnusson, S. P., Kjaer, M. Lack of tissue renewal in human adult Achilles tendon is revealed by nuclear bomb 14C. PMID:23401563

  9. Rotator cuff tendon connections with the rotator cable.

    PubMed

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  10. Is there still a place for Achilles tendon lengthening?

    PubMed

    Tagoe, Mark T; Reeves, Neil D; Bowling, Frank L

    2016-01-01

    Patients with diabetes and ankle equinus are at particularly high risk for forefoot ulceration because of the development of high forefoot pressures. Stiffness in the triceps surae muscles and tendons are thought to be largely responsible for equinus in patients with diabetes and underpins the surgical rationale for Achilles tendon lengthening (ATL) procedures to alleviate this deformity and reduce ulcer risk. The established/traditional surgical approach is the triple hemisection along the length of the Achilles tendon. Although the percutaneous approach has been successful in achieving increases in ankle dorsiflexion >30°, the tendon rupture risk has led to some surgeons looking at alternative approaches. The gastrocnemius aponeurosis may be considered as an alternative because of the Achilles tendon's poor blood supply. ATL procedures are a balance between achieving adequate tendon lengthening and minimizing tendon rupture risk during or after surgery. After ATL surgery, the first 7 days should involve reduced loading and protected range of motion to avoid rupture, after which gradual reintroduction to loading should be encouraged to increase tendon strength. In summary, there is a moderate level of evidence to support surgical intervention for ankle joint equinus in patients with diabetes and forefoot ulceration that is non-responsive to other conservative treatments. Areas of caution for ATL procedures include the risk for overcorrection, tendon rupture and the tendon's poor blood supply. Further prospective randomized control trials are required to confirm the benefits of ATL procedures over conservative care and the most optimal anatomical sites for surgical intervention. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Differential Motion and Compression Between the Plantaris and Achilles Tendons: A Contributing Factor to Midportion Achilles Tendinopathy?

    PubMed

    Stephen, Joanna M; Marsland, Daniel; Masci, Lorenzo; Calder, James D F; Daou, Hadi El

    2018-03-01

    The plantaris tendon (PT) has been thought to contribute to symptoms in a proportion of patients with Achilles midportion tendinopathy, with symptoms improving after PT excision. There is compression and differential movement between the PT and Achilles tendon (AT) during ankle plantarflexion and dorsiflexion. Descriptive laboratory study. Eighteen fresh-frozen cadaveric ankles (mean ± SD age: 35 ± 7 years, range = 27-48 years; men, n = 9) were mounted in a customized testing rig, where the tibia was fixed but the forefoot could be moved freely. A Steinmann pin was drilled through the calcaneus, enabling a valgus torque to be applied. The soleus, gastrocnemius, and plantaris muscles were loaded with 63 N with a weighted pulley system. The test area was 40 to 80 mm above the os calcis, corresponding to where the injury is observed clinically. Medially, the AT and PT were exposed, and a calibrated flexible pressure sensor was inserted between the tendons. Pressure readings were recorded with the ankle in full dorsiflexion, full plantarflexion, and plantargrade and repeated in these positions with a 5 N·m torque, simulating increased hindfoot valgus. The pressure sensor was removed and the PT and AT marked with ink at the same level, with the foot held in neutral rotation and plantargrade. Videos and photographs were taken to assess differential motion between the tendons. After testing, specimens were dissected to identify the PT insertion. One-way analysis of variance and paired t tests were performed to make comparisons. The PT tendons with an insertion separate from the AT demonstrated greater differential motion through range (14 ± 4 mm) when compared with those directly adherent to the AT (2 ± 2 mm) ( P < .001). Mean pressure between the PT and AT rose in terminal plantarflexion for all specimens ( P < .001) and was more pronounced with hindfoot valgus ( P < .001). The PT inserting directly into the calcaneus resulted in significantly greater differential motion as compared with the AT. Tendon compression was elevated in terminal plantarflexion, suggesting that adapting rehabilitation tendon-loading programs to avoid this position may be beneficial. The insertion pattern of the PT may be a factor in plantaris-related midportion Achilles tendinopathy. Terminal range plantarflexion and hindfoot valgus both increased AT and PT compression, suggesting that these should be avoided in this patient population.

  12. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    PubMed

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  14. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  15. Age-dependent effects of systemic administration of oxytetracycline on the viscoelastic properties of rat tail tendons as a mechanistic basis for pharmacological treatment of flexural limb deformities in foals.

    PubMed

    Wintz, Leslie R; Lavagnino, Michael; Gardner, Keri L; Sedlak, Aleksa M; Arnoczky, Steven P

    2012-12-01

    To describe the effect of systemically administered oxytetracycline on the viscoelastic properties of rat tail tendon fascicles (TTfs) to provide a mechanistic rationale for pharmacological treatment of flexural limb deformities in foals. TTfs from ten 1-month-old and ten 6-month-old male Sprague-Dawley rats. 5 rats in each age group were administered oxytetracycline (50 mg/kg, IP, q 24 h) for 4 days. The remaining 5 rats in each age group served as untreated controls. Five days after initiation of oxytetracycline treatment, TTfs were collected and their viscoelastic properties were evaluated via a stress-relaxation protocol. Maximum modulus and equilibrium modulus were compared via a 2-way ANOVA. Collagen fibril size, density, and orientation in TTfs were compared between treated and control rats. Viscoelastic properties were significantly decreased in TTfs from 1-month-old oxytetracycline-treated rats, compared with those in TTfs from 1-month-old control rats. Oxytetracycline had no effect on the viscoelastic properties of TTfs from 6-month-old rats. Collagen fibril size, density, and orientation in TTfs from 1-month-old rats did not differ between oxytetracycline-treated and control rats. Results confirmed that systemically administered oxytetracycline decreased the viscoelastic properties of TTfs from 1-month-old rats but not those of TTfs from 6-month-old rats. The decrease in viscoelastic properties associated with oxytetracycline treatment does not appear to be caused by altered collagen fibril diameter or organization. The age-dependent effect of oxytetracycline on the viscoelastic properties of tendons may be related to its effect on the maturation of the extracellular matrix of developing tendons.

  16. Monitoring tissue formation and organization of engineered tendon by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Bagnaninchi, P. O.; Yang, Y.; Maffulli, N.; Wang, R. K.; El Haj, A.

    2006-02-01

    The uniaxial orientation and bundle formation of collagen fibres determine the mechanical properties of tendons. Thus the particular challenge of tendon tissue engineering is to build the tissue with a highly organized structure of collagen fibres. Ultimately the engineered construct will be used as autologous grafts in tendon surgery, withstanding physiological loading. We grew pig tenocytes in porous chitosan scaffolds with multiple microchannels of 250-500 μm. The cell proliferation and production of extra-cellular matrix (ECM) within the scaffolds have been successfully monitored by Optical Coherence Tomography (OCT), a bench-top OCT system equipped with a broadband light source centred at 1300 nm. Under sterile condition, the measurements were performed on-line and in a non-destructive manner. In addition, a novel method based on OCT imaging, which calculates the occupation ratio of the microchannel derived from the scattered intensity has been developed. It is confirmed that the occupation ratio is correlated to cell proliferation and ECM production in the scaffolds. Thus this method has been utilised to assess the effect of different culture conditions on the tissue formation. The use of a perfusion bioreactor has resulted in a significantly (p<1e -3) higher cell proliferation and matrix production.

  17. Traumatic Extensor Tendon Injuries to the Hand: Clinical Anatomy, Biomechanics, and Surgical Procedure Review.

    PubMed

    Colzani, Giulia; Tos, Pierluigi; Battiston, Bruno; Merolla, Giovanni; Porcellini, Giuseppe; Artiaco, Stefano

    2016-04-01

    The extensor apparatus is a complex muscle-tendon system that requires integrity or optimal reconstruction to preserve hand function. Anatomical knowledge and the understanding of physiopathology of extensor tendons are essential for an accurate diagnosis of extensor tendon injuries (ETIs) of the hand and wrist, because these lesions are complex and commonly observed in clinical practice. A careful clinical history and assessment still remain the first step for the diagnosis, followed by US and MR to confirm the suspect of ETI or to investigate some doubtful conditions and rule out associate lesions. During last decades the evolution of surgical techniques and rehabilitative treatment protocol led to gradual improvement in clinical results of ETI treatment and surgical repair. Injury classification into anatomical zones and the evaluation of the characteristics of the lesions are considered key points to select the appropriate treatment for ETI. Both conservative and surgical management can be indicated in ETI, depending on the anatomical zone and on the characteristics of the injuries. As a general rule, an attempt of conservative treatment should be performed when the lesion is expected to have favorable result with nonoperative procedure. Many surgical techniques have been proposed over the time and with favorable results if the tendon injury is not underestimated and adequately treated. Despite recent research findings, a lack of evidence-based knowledge is still observed in surgical treatment and postoperative management of ETI. Further clinical and biomechanical investigations would be advisable to clarify this complex issue.

  18. Traumatic Extensor Tendon Injuries to the Hand: Clinical Anatomy, Biomechanics, and Surgical Procedure Review

    PubMed Central

    Colzani, Giulia; Tos, Pierluigi; Battiston, Bruno; Merolla, Giovanni; Porcellini, Giuseppe; Artiaco, Stefano

    2016-01-01

    The extensor apparatus is a complex muscle-tendon system that requires integrity or optimal reconstruction to preserve hand function. Anatomical knowledge and the understanding of physiopathology of extensor tendons are essential for an accurate diagnosis of extensor tendon injuries (ETIs) of the hand and wrist, because these lesions are complex and commonly observed in clinical practice. A careful clinical history and assessment still remain the first step for the diagnosis, followed by US and MR to confirm the suspect of ETI or to investigate some doubtful conditions and rule out associate lesions. During last decades the evolution of surgical techniques and rehabilitative treatment protocol led to gradual improvement in clinical results of ETI treatment and surgical repair. Injury classification into anatomical zones and the evaluation of the characteristics of the lesions are considered key points to select the appropriate treatment for ETI. Both conservative and surgical management can be indicated in ETI, depending on the anatomical zone and on the characteristics of the injuries. As a general rule, an attempt of conservative treatment should be performed when the lesion is expected to have favorable result with nonoperative procedure. Many surgical techniques have been proposed over the time and with favorable results if the tendon injury is not underestimated and adequately treated. Despite recent research findings, a lack of evidence-based knowledge is still observed in surgical treatment and postoperative management of ETI. Further clinical and biomechanical investigations would be advisable to clarify this complex issue. PMID:27616821

  19. Postoperative ultrasonography of the musculoskeletal system.

    PubMed

    Chun, Kyung Ah; Cho, Kil-Ho

    2015-07-01

    Ultrasonography of the postoperative musculoskeletal system plays an important role in the accurate diagnosis of abnormal lesions in the bone and soft tissues. Ultrasonography is a fast and reliable method with no harmful irradiation for the evaluation of postoperative musculoskeletal complications. In particular, it is not affected by the excessive metal artifacts that appear on computed tomography or magnetic resonance imaging. Another benefit of ultrasonography is its capability to dynamically assess the pathologic movement in joints, muscles, or tendons. This article discusses the frequent applications of musculoskeletal ultrasonography in various postoperative situations including those involving the soft tissues around the metal hardware, arthroplasty, postoperative tendons, recurrent soft tissue tumors, bone unions, and amputation surgery.

  20. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    PubMed

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

Top