The past 20 years have brought the recognition that an important factor in the health of people in indoor environments is the dampness of the buildings in which they live and work. Furthermore, it is now appreciated that the principal biology responsible for the health problems i...
Richardson, George; Barton, Andrew; Basham, Meryl; Foy, Chris; Eick, Susan Ann; Somerville, Margaret
2006-05-15
A three-year study (1999-2001) was initiated in the UK to assess the effect of improving housing conditions in 3-4 bedroom, single-family unit, social rented sector houses on the health of the occupants. The houses were randomised into two groups. Phase I houses received extensive upgrading including wet central heating, on demand ventilation, double-glazed doors, cavity wall and roof/loft insulation. An identical intervention for Phase II houses was delayed for one year. As part of this randomised waiting list study, discrete measurements were made of indoor environmental variables in each house, to assess the short-term effects of improving housing conditions on the indoor environment. Variables representative of indoor environmental conditions were measured in the living room, bedroom and outdoors in each of the three years of the study. In 2000, there was a significant difference between the changes from 1999 to 2000 between Phase I (upgraded) and II (not then upgraded) houses for bedroom temperatures (p=0.002). Changes in wall surface dampness and wall dampness in Phase I houses were also significantly different to the change in Phase II houses in 2000 (p=0.001), but by 2001 the Phase I houses had reverted to the same dampness levels they had before upgrading. The housing upgrades increased bedroom temperatures in all houses. Other indoor environmental variables were not affected.
Indoor exposures and recurrent wheezing in infants: a study in the BAMSE cohort.
Emenius, G; Svartengren, M; Korsgaard, J; Nordvall, L; Pershagen, G; Wickman, M
2004-07-01
The aim of this study was to examine the relationship between indoor exposures and the home environment, and the development of recurrent wheezing during infancy. A birth cohort, comprising 4089 children, was followed. Information on exposures was obtained shortly after birth, and episodes of wheezing were recorded when the infants were 1 and 2 y of age. In a nested case-control study, 181 infants were enrolled, who had three or more reported episodes of wheezing after 3 mo of age combined with either use of inhaled steroids or symptoms of bronchial hyper-reactivity, and 359 age-matched controls. Home inspections were performed during the winter following enrolment, and indoor conditions were measured. Adjusted odds ratios (OR) and 95% confidence intervals (CI) were calculated. The OR for recurrent infant wheezing associated with signs of dampness reported prospectively by parents was 1.4 (0.9-2.2), and the OR for observed signs of dampness at home inspections was 1.6 (1.0-2.5). A trend was found in the risk of recurrent wheezing in relation to the number of indicators of dampness: OR 1.3 (0.8-2.2) for one sign of dampness and OR 2.7 (1.3-5.4) for three or more signs of dampness. Newly painted surfaces in the child's bedroom was associated with an increased OR for recurrent wheezing: 1.7 (1.3-2.6). Indicators of dampness, as well as recently repainted interior surfaces, appear to be associated with recurrent infant wheezing, with a strengthened effect of combined indoor exposures.
Mendell, M J; Heath, G A
2005-02-01
To assess whether school environments can adversely affect academic performance, we review scientific evidence relating indoor pollutants and thermal conditions, in schools or other indoor environments, to human performance or attendance. We critically review evidence for direct associations between these aspects of indoor environmental quality (IEQ) and performance or attendance. Secondarily, we summarize, without critique, evidence on indirect connections potentially linking IEQ to performance or attendance. Regarding direct associations, little strongly designed research was available. Persuasive evidence links higher indoor concentrations of NO(2) to reduced school attendance, and suggestive evidence links low ventilation rates to reduced performance. Regarding indirect associations, many studies link indoor dampness and microbiologic pollutants (primarily in homes) to asthma exacerbations and respiratory infections, which in turn have been related to reduced performance and attendance. Also, much evidence links poor IEQ (e.g. low ventilation rate, excess moisture, or formaldehyde) with adverse health effects in children and adults and documents dampness problems and inadequate ventilation as common in schools. Overall, evidence suggests that poor IEQ in schools is common and adversely influences the performance and attendance of students, primarily through health effects from indoor pollutants. Evidence is available to justify (i) immediate actions to assess and improve IEQ in schools and (ii) focused research to guide IEQ improvements in schools. There is more justification now for improving IEQ in schools to reduce health risks to students than to reduce performance or attendance risks. However, as IEQ-performance links are likely to operate largely through effects of IEQ on health, IEQ improvements that benefit the health of students are likely to have performance and attendance benefits as well. Immediate actions are warranted in schools to prevent dampness problems, inadequate ventilation, and excess indoor exposures to substances such as NO(2) and formaldehyde. Also, siting of new schools in areas with lower outdoor pollutant levels is preferable.
Respiratory health effects of the indoor environment in a population of Dutch children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dijkstra, L.; Houthuijs, D.; Brunekreef, B.
1990-11-01
The effect of indoor exposure to nitrogen dioxide on respiratory health was studied over a period of 2 yr in a population of nonsmoking Dutch children 6 to 12 yr of age. Lung function was measured at the schools, and information on respiratory symptoms was collected from a self-administered questionnaire completed by the parents of the children. Nitrogen dioxide was measured in the homes of all children with Palmes' diffusion tubes. In addition, information on smoking and dampness in the home was collected by questionnaire. There was no relationship between exposure to nitrogen dioxide in the home and respiratory symptoms.more » Respiratory symptoms were found to be associated with exposure to tobacco smoke and home dampness. There was a weak, negative association between maximal midexpiratory flow (MMEF) and exposure to nitrogen dioxide. FEV1, peak expiratory flow, and MMEF were all negatively associated with exposure to tobacco smoke. Home dampness was not associated with pulmonary function. Lung function growth, measured over a period of 2 yr, was not consistently associated with any of the indoor exposure variables. The development of respiratory symptoms over time was not associated with indoor exposure to nitrogen dioxide. There was a significant association between exposure to environmental tobacco smoke in the home and the development of wheeze. There was also a significant association between home dampness and the development of cough.« less
INDOOR MOLDS AND ALLERGIC POTENTIAL
Rationale: Damp/moldy environments have been associated with asthma exacerbation, but mold¿s role in allergic asthma induction is less clear. Recently, 5 molds were statistically associated with water-damaged asthmatic homes in the Cleveland area. The asthma exacerbation...
Molds are ubiquitous in the environment and exposures to molds contribute to various human diseases. Damp/moldy environments have been associated with asthma exacerbation, but mold's role in allergic asthma induction is less clear. The molds selected for these studies are commonl...
ALLERGIC POTENTIAL OF INDOOR MOLDS
Many fungi have been associated with allergic lung disease, but few are well studied and even fewer allergens of fungal origin are well characterized. Exposure to damp moldy environments has been associated with the exacerbation of asthma, but the role of molds in the induction o...
Exposure and Health Effects of Fungi on Humans
Baxi, Sachin N.; Portnoy, Jay M.; Larenas-Linnemann, Désirée; Phipatanakul, Wanda
2016-01-01
Fungi are ubiquitous microorganisms that are present in outdoor and indoor environments. Previous research has found relationships between environmental fungal exposures and human health effects. We reviewed recent articles focused on fungal exposure and dampness as risk factors for respiratory disease development, symptoms and hypersensitivity. In particular, we reviewed the evidence suggesting that early exposure to dampness or fungi is associated with development of asthma and increased asthma morbidity. While outdoor exposure to high concentrations of spores can cause health effects such as asthma attacks in association with thunderstorms, most people appear to be relatively unaffected unless they are sensitized to specific genera. Indoor exposure and dampness, on the other hand, appears to be associated with increased risk of developing asthma in young children and asthma morbidity in individuals who have asthma. These are important issues because they provide a rationale for interventions that might be considered for homes and buildings in which there is increased fungal exposure. In addition to rhinitis and asthma, fungus exposure is associated with a number of other illnesses including allergic bronchopulmonary mycoses, allergic fungal sinusitis and hypersensitivity pneumonitis. Additional research is necessary to establish causality and evaluate interventions for fungal and dampness-related health effects. PMID:26947460
Assessing the Allergenic Potential of Molds Found in Water-Damaged Homes in a Mouse Model
Damp/moldy indoor environments, which have resulted from flooding events and may increase as a result of climate change, have been associated with asthma exacerbation. Certain molds found in significantly higher or lower concentrations in asthmatics’ homes compared to control ho...
Asthma symptoms in relation to building dampness and odour in older multifamily houses in Stockholm.
Engvall, K; Norrby, C; Norbäck, D
2001-05-01
Respiratory symptoms and hay fever in adults in relation to the indoor environment. To study relationships between reports on respiratory symptoms and hay fever and building dampness and odours in older multifamily dwellings. A questionnaire study in a random sample of 231 multifamily buildings built before 1961, which included 4224 apartments. The response rate was 77% (n = 3241). Information on building characteristics was gathered from building owners and the central building register in Stockholm. Multiple logistic regression analysis was applied, adjusting for age, sex, current smoking, population density, type of ventilation and ownership. In total, 22% reported at least one sign of dampness, and 32% reported odour in the dwelling. All types of odours were more common in damp buildings. Reports on dampness and odours were related to asthma symptoms and current cough, even when adjusting for potential confounders. A combination of odour and signs of high air humidity was related to an increase in asthma symptoms (OR = 2.82; 95%CI 2.70-2.95) and current cough (OR = 5.29; 95%CI 4.99-5.62). Similar findings were observed for a combination of odour and history of water leakage in the last 5 years, with an increase in asthma symptoms (OR = 3.59; 95%CI 3.37-3.82) and current cough (OR = 2.86; 95%CI 2.61-3.14). There was a dose-response relationship between respiratory symptoms and the number of signs of dampness. An association was also observed between dampness and a history of pollen allergy. Signs of high indoor air humidity, water leakage and odours were common, and related to respiratory symptoms. Exposure to odorous compounds from building dampness may be significant with respect to respiratory symptoms and possibly atopic sensitisation.
Building characteristics associated with moisture related problems in 8,918 Swedish dwellings.
Hägerhed-Engman, Linda; Bornehag, Carl-Gustaf; Sundell, Jan
2009-08-01
Moisture problems in buildings have in a number of studies been shown to increase the risk for respiratory symptoms. The study Dampness in Buildings and Health (DBH) was initiated with the aim to identify health relevant exposures related to dampness in buildings. A questionnaire study about home environment with a focus on dampness problems and health was conducted in one county of Sweden (8,918 homes, response rate 79%). Building characteristics that were associated with one or more of the dampness indicators were for single-family houses, older houses, flat-roofed houses built in the 1960s and 1970s, houses with a concrete slab on the ground that were built before 1983. Moreover, tenancy and earlier renovation due to mould or moisture problems was strongly associated with dampness. A perception of dry air was associated with window-pane condensation, e.g. humid indoor air.
Sun, Y; Zhang, Y; Sundell, J; Fan, Z; Bao, L
2009-04-01
A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June10, 2006, to survey the association between dampness in dorms and allergy and airways infection among college students. The health and dampness condition were self-reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The allergy and airways infection symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. This study showed there was significantly positive association between condensation and dry cough. Eczema was often reported in rooms with suspected moisture problem. Dampness was a significantly risk factor for common cold. This paper indicated that dampness problem at dorms of Chinese students was a risk factor in irritating allergic symptoms, and hence there is a need for dorm environment improvement. The ventilation and microbiology problems in dorm environment corresponding to dampness should be further studied, especially when it is associated to occupants' health.
Mendell, Mark J.; Mirer, Anna G.; Cheung, Kerry; Tong, My; Douwes, Jeroen
2011-01-01
Objectives Many studies have shown consistent associations between evident indoor dampness or mold and respiratory or allergic health effects, but causal links remain unclear. Findings on measured microbiologic factors have received little review. We conducted an updated, comprehensive review on these topics. Data sources We reviewed eligible peer-reviewed epidemiologic studies or quantitative meta-analyses, up to late 2009, on dampness, mold, or other microbiologic agents and respiratory or allergic effects. Data extraction We evaluated evidence for causation or association between qualitative/subjective assessments of dampness or mold (considered together) and specific health outcomes. We separately considered evidence for associations between specific quantitative measurements of microbiologic factors and each health outcome. Data synthesis Evidence from epidemiologic studies and meta-analyses showed indoor dampness or mold to be associated consistently with increased asthma development and exacerbation, current and ever diagnosis of asthma, dyspnea, wheeze, cough, respiratory infections, bronchitis, allergic rhinitis, eczema, and upper respiratory tract symptoms. Associations were found in allergic and nonallergic individuals. Evidence strongly suggested causation of asthma exacerbation in children. Suggestive evidence was available for only a few specific measured microbiologic factors and was in part equivocal, suggesting both adverse and protective associations with health. Conclusions Evident dampness or mold had consistent positive associations with multiple allergic and respiratory effects. Measured microbiologic agents in dust had limited suggestive associations, including both positive and negative associations for some agents. Thus, prevention and remediation of indoor dampness and mold are likely to reduce health risks, but current evidence does not support measuring specific indoor microbiologic factors to guide health-protective actions. PMID:21269928
Quality of life of patients with asthma related to damp and moldy work environments.
Karvala, Kirsi; Uitti, Jukka; Luukkonen, Ritva; Nordman, Henrik
2013-01-01
Long-term outcomes of asthma related to exposure to workplace dampness are not well known. The aim of this study was to evaluate the quality of life (QOL) of patients with asthma related to damp and moldy workplaces and characterize factors influencing QOL. Using a questionnaire, we followed 1267 patients previously examined for suspected occupational respiratory disease related to exposure to damp and moldy indoor environments. In addition to demographic and other background data, the questionnaire included sections on current employment status, QOL, anxiety and depression, somatization, hypochondria, and asthma medication. We compared the QOL of patients with occupational asthma (OA) with that of patients with work-exacerbated asthma (WEA) or symptoms without asthma. Impaired QOL was found among patients diagnosed with OA when they were compared with patients in corresponding environments with WEA or symptoms only. Not working and greater use of asthma medication were major determinants of worse QOL. Psychological factors did not explain the differences between the groups. OA induced by exposure to workplace moisture and molds is associated with QOL deterioration. The impairment is related to being unemployed (due to disability, retirement, job loss or other reasons) and the need for medication.
Employing ASHRAE Standard 62-1989 in urban building environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1991-01-01
Indoor air quality (IAQ) is a result of a complex relationship between the contamination sources in a building, the ventilation rate, and the dilution of the indoor air contaminant concentrations with outdoor air. This complex relationship is further complicated by outdoor sources used for dilution air and pollution sinks in a building which may modify or remove contaminants. This paper reports that the factors influencing IAQ in a building are: emissions from indoor contamination sources, dilution rate of outdoor ventilation air, quality of the outdoor dilution air, and systems and materials in a building that change the concentrations of contaminants.more » Emissions from contaminant sources in a building are the primary determinant of IAQ. They include building materials, consumer products, cleaners, furnishings, combustion appliances and processes, biological growth from standing water and damp surfaces and building occupants. These factors combined with the emissions from indoor air contamination sources such as synthetic building materials, modern office equipment, and cleaning and biological agents are believed to increase the levels of indoor air contamination. The physiological reactions to these contaminants, coupled with the psychosocial stresses of the modern office environment, and the wide range of human susceptibility to indoor air contaminants led to the classification of acute building sicknesses: sick building syndrome (SBS), building-related illness (BRI), and multiple chemical sensitivity (MCS).« less
Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.
Norbäck, D; Björnsson, E; Janson, C; Widström, J; Boman, G
1995-01-01
OBJECTIVES--As a part of the worldwide European Community respiratory health survey, possible relations between symptoms of asthma, building characteristics, and indoor concentration of volatile organic compounds (VOCs) in dwellings were studied. METHODS--The study comprised 88 subjects, aged 20-45 years, from the general population in Uppsala, a mid-Swedish urban community, selected by stratified random sampling. Room temperature, air humidity, respirable dust, carbon dioxide (CO2), VOCs, formaldehyde, and house dust mites were measured in the homes of the subjects. They underwent a structured interview, spirometry, peak expiratory flow (PEF) measurements at home, methacholine provocation test for bronchial hyperresponsiveness, and skin prick tests. In addition, serum concentration of eosinophilic cationic protein (S-ECP), blood eosinophil count, and total immunoglobulin E (S-IgE) were measured. RESULTS--Symptoms related to asthma were more common in dwellings with house dust mites, and visible signs of dampness or microbial growth in the building. Significant relations were also found between nocturnal breathlessness and presence of wall to wall carpets, and indoor concentration of CO2, formaldehyde, and VOCs. The formaldehyde concentration exceeded the Swedish limit value for dwellings (100 micrograms/m3) in one building, and CO2 exceeded the recommended limit value of 1000 ppm in 26% of the dwellings, showing insufficient outdoor air supply. Bronchial hyperresponsiveness was related to indoor concentration of limonene, the most prevalent terpene. Variability in PEF was related to two other terpenes; alpha-pinen and delta-karen. CONCLUSION--Our results suggest that indoor VOCs and formaldehyde may cause asthma-like symptoms. There is a need to increase the outdoor air supply in many dwelling, and wall to wall carpeting and dampness in the building should be avoided. Improved indoor environment can also be achieved by selecting building materials, building construction, and indoor activities on the principle that the emission of volatile organic compounds should be as low as reasonably achievable, to minimise symptoms related to asthma due to indoor air pollution. PMID:7627316
Do indoor environments in schools influence student performance? A review of the literature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendell, Mark J.; Heath, Garvin A.
2004-11-24
Limited research is available on potential adverse effects of school environments on academic performance, despite strong public concern. We examine the scientific evidence relevant to this relationship by reviewing available research relating schools and other indoor environments to human performance or attendance. As a primary focus, we critically review evidence for direct relationships between indoor environmental quality (IEQ) in buildings and performance or attendance. As a secondary focus, we summarize, without critique, evidence on potential connections indirectly linking IEQ to performance or attendance: relationships between IEQ and health, between health and performance or attendance, and between attendance and performance. Themore » most persuasive direct evidence showed increases in indoor concentrations of nitrogen dioxide and outdoor concentrations of several specific pollutants to be related to reduced school attendance. The most persuasive indirect evidence showed indoor dampness and microbiologic pollutants to be related to asthma and respiratory infections, which have in turn been related to reduced performance and attendance. Furthermore, a substantial scientific literature links poor IEQ (e.g., low ventilation rate, excess moisture or formaldehyde) with respiratory and other health effects in children and adults. Overall, evidence suggests that poor IEQ in schools can influence the performance and attendance of students, primarily through health effects from indoor pollutants. Also, inadequate IEQ in schools seems sufficiently common to merit strong public concern. Evidence is available to justify (1) immediate actions to protect IEQ in schools and (2) focused research on exposures, prevention, and causation, to better guide policies and actions on IEQ in schools.« less
Dampness and Moisture Problems in Norwegian Homes
Becher, Rune; Høie, Anja Hortemo; Bakke, Jan Vilhelm; Holøs, Sverre Bjørn; Øvrevik, Johan
2017-01-01
The occurrence of dampness and mold in the indoor environment is associated with respiratory-related disease outcomes. Thus, it is pertinent to know the magnitude of such indoor environment problems to be able to estimate the potential health impact in the population. In the present study, the moisture damage in 10,112 Norwegian dwellings was recorded based on building inspection reports. The levels of moisture damage were graded based on a condition class (CC), where CC0 is immaculate and CC1 acceptable (actions not required), while CC2 and CC3 indicate increased levels of damage that requires action. Of the 10,112 dwellings investigated, 3125 had verified moisture or mold damage. This amounts to 31% of the surveyed dwellings. Of these, 27% had CC2 as the worst grade, whereas 4% had CC3 as the worst grade level. The room types and building structures most prone to moisture damage were (in rank order) crawl spaces, basements, un-insulated attics, cooling rooms, and bathrooms. The high proportion of homes with moisture damage indicate a possible risk for respiratory diseases in a relatively large number of individuals, even if only the more extensive moisture damages and those located in rooms where occupants spend the majority of their time would have a significant influence on adverse health effects. PMID:29039816
Sun, Y; Zhang, Y; Sundell, J; Fan, Z; Bao, L
2009-08-01
A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June 10, 2006, to survey the association between dampness in dorms, and allergy and airways infections among college students. The health and dampness conditions were self-reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. There was a significant positive association between condensation and dry cough. Eczema was often reported in rooms with moisture problem. Dampness was a significant risk factor for common cold. Dampness problems in dorms of Chinese students are a risk factor for allergic symptoms, and hence there is a need for dorm environment improvement. Health problems related to ventilation and microbiology problems in dorms should be further studied.
Indoor mold, toxigenic fungi, and Stachybotrys chartarum: infectious disease perspective.
Kuhn, D M; Ghannoum, M A
2003-01-01
Damp buildings often have a moldy smell or obvious mold growth; some molds are human pathogens. This has caused concern regarding health effects of moldy indoor environments and has resulted in many studies of moisture- and mold-damaged buildings. Recently, there have been reports of severe illness as a result of indoor mold exposure, particularly due to Stachybotrys chartarum. While many authors describe a direct relationship between fungal contamination and illness, close examination of the literature reveals a confusing picture. Here, we review the evidence regarding indoor mold exposure and mycotoxicosis, with an emphasis on S. chartarum. We also examine possible end-organ effects, including pulmonary, immunologic, neurologic, and oncologic disorders. We discuss the Cleveland infant idiopathic pulmonary hemorrhage reports in detail, since they provided important impetus for concerns about Stachybotrys. Some valid concerns exist regarding the relationship between indoor mold exposure and human disease. Review of the literature reveals certain fungus-disease associations in humans, including ergotism (Claviceps species), alimentary toxic aleukia (Fusarium), and liver disease (Aspergillys). While many papers suggest a similar relationship between Stachybotrys and human disease, the studies nearly uniformly suffer from significant methodological flaws, making their findings inconclusive. As a result, we have not found well-substantiated supportive evidence of serious illness due to Stachybotrys exposure in the contemporary environment. To address issues of indoor mold-related illness, there is an urgent need for studies using objective markers of illness, relevant animal models, proper epidemiologic techniques, and examination of confounding factors.
Indoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective
Kuhn, D. M.; Ghannoum, M. A.
2003-01-01
Damp buildings often have a moldy smell or obvious mold growth; some molds are human pathogens. This has caused concern regarding health effects of moldy indoor environments and has resulted in many studies of moisture- and mold-damaged buildings. Recently, there have been reports of severe illness as a result of indoor mold exposure, particularly due to Stachybotrys chartarum. While many authors describe a direct relationship between fungal contamination and illness, close examination of the literature reveals a confusing picture. Here, we review the evidence regarding indoor mold exposure and mycotoxicosis, with an emphasis on S. chartarum. We also examine possible end-organ effects, including pulmonary, immunologic, neurologic, and oncologic disorders. We discuss the Cleveland infant idiopathic pulmonary hemorrhage reports in detail, since they provided important impetus for concerns about Stachybotrys. Some valid concerns exist regarding the relationship between indoor mold exposure and human disease. Review of the literature reveals certain fungus-disease associations in humans, including ergotism (Claviceps species), alimentary toxic aleukia (Fusarium), and liver disease (Aspergillys). While many papers suggest a similar relationship between Stachybotrys and human disease, the studies nearly uniformly suffer from significant methodological flaws, making their findings inconclusive. As a result, we have not found well-substantiated supportive evidence of serious illness due to Stachybotrys exposure in the contemporary environment. To address issues of indoor mold-related illness, there is an urgent need for studies using objective markers of illness, relevant animal models, proper epidemiologic techniques, and examination of confounding factors. PMID:12525430
Cross Section of Legislative Approaches to Reducing Indoor Dampness and Mold
Boese, Gerald W.
2017-01-01
Exposure to indoor dampness and mold is associated with numerous adverse respiratory conditions, including asthma. While no quantitative health-based threshold currently exists for mold, the conditions that support excessive dampness and mold are known and preventable; experts agree that controlling these conditions could lead to substantial savings in health care costs and improvement in public health. This article reviews a sample of state and local policies to limit potentially harmful exposures. Adoption of laws to strengthen building codes, specify dampness and mold in habitability laws, regulate mold contractors, and other legislative approaches are discussed, as are key factors supporting successful implementation. Communicating these lessons learned could accelerate the process for other jurisdictions considering similar approaches. Information about effectiveness of legislation as prevention is lacking; thus, evaluation could yield important information to inform the development of model state or local laws that significantly address mold as a public health concern. PMID:27977504
Relation of indoor and outdoor airborne fungal spore levels in the Kansas City metropolitan area.
Jara, David; Portnoy, Jay; Dhar, Minati; Barnes, Charles
2017-03-01
Environmental control is an important component of asthma management for persons with asthma. A damp indoor environment and elevated airborne spore levels are factors in housing environmental control. We investigated if indoor airborne fungal spore levels correlated with outdoor ground-level airborne fungal spores or outdoor centrally collected spore levels as to types and abundance. Air collections were taken from home interiors, outdoor areas adjacent to the homes, and at a central location in the metropolitan area at the approximate same time. All air collections were examined and enumerated microscopically, and airborne spore estimates per cubic meter of air were reported for total fungal spores and for 11 identifiable spore groups. The 244 homes in the study were typical of the North American Midwest. The overall mean total spore counts in spores per cubic meter of air was indoors (4076 spores/m3), outdoors at ground level (8899 spores/m3), and outdoor metropolitan area (8342 spores/m3). All of the major indoor taxa were strongly correlated with the mean total spores present in the home. Total outdoor ground spore levels were highly correlated with levels of major outdoor taxa, such as ascospores and Cladosporium. Correlations of indoor spore levels with outdoor spore levels are strong for most major outdoor taxa. Indoor Aspergillus-Penicillium and Chaetomium are significantly correlated between indoor and local ground-level outdoor air. Although conditions may exist where indoor or outdoor spore levels were not well aligned, in most circumstances, the outdoor airborne spore community was reflected in the indoor airborne spore community.
Damp building-related illnesses (DBRI) include a myriad of respiratory, immunologic, and neurologic symptoms that are sometimes etiologically linked to aberrant indoor growth of the toxic black mold, Stachybotrys chartarum. Although supportive evidence for such linkages is limite...
Neurotoxicity of fungal volatile organic compounds in Drosophila melanogaster.
Inamdar, Arati A; Masurekar, Prakash; Bennett, Joan Wennstrom
2010-10-01
Many volatile organic compounds (VOCs) are found in indoor environment as products of microbial metabolism. In damp indoor environments, fungi are associated with poor air quality. Some epidemiological studies have suggested that microbial VOCs have a negative impact on human health. Our study was designed to provide a reductionist approach toward studying fungal VOC-mediated toxicity using the inexpensive model organism, Drosophila melanogaster, and pure chemical standards of several important fungal VOCs. Low concentrations of the following known fungal VOCs, 0.1% of 1-octen-3-ol and 0.5% of 2-octanone; 2,5 dimethylfuran; 3-octanol; and trans-2-octenal, caused locomotory defects and changes in green fluorescent protein (GFP)- and antigen-labeled dopaminergic neurons in adult D. melanogaster. Locomotory defects could be partially rescued with L-DOPA. Ingestion of the antioxidant, vitamin E, improved the survival span and delayed the VOC-mediated changes in dopaminergic neurons, indicating that the VOC-mediated toxicity was due, in part, to generation of reactive oxygen species.
Jaakkola, Maritta S; Nordman, Henrik; Piipari, Ritva; Uitti, Jukka; Laitinen, Jukka; Karjalainen, Antti; Hahtola, Paula; Jaakkola, Jouni J K
2002-01-01
Previous cross-sectional and prevalent case-control studies have suggested increased risk of asthma in adults related to dampness problems and molds in homes. We conducted a population-based incident case-control study to assess the effects of indoor dampness problems and molds at work and at home on development of asthma in adults. We recruited systematically all new cases of asthma during a 2.5-year study period (1997-2000) and randomly selected controls from a source population consisting of adults 21-63 years old living in the Pirkanmaa Hospital district, South Finland. The clinically diagnosed case series consisted of 521 adults with newly diagnosed asthma and the control series of 932 controls, after we excluded 76 (7.5%) controls with a history of asthma. In logistic regression analysis adjusting for confounders, the risk of asthma was related to the presence of visible mold and/or mold odor in the workplace (odds ratio, 1.54; 95% confidence interval, 1.01-2.32) but not to water damage or damp stains alone. We estimated the fraction of asthma attributable to workplace mold exposure to be 35.1% (95% confidence interval, 1.0-56.9%) among the exposed. Present results provide new evidence of the relation between workplace exposure to indoor molds and adult-onset asthma. PMID:12003761
Kang, Hyun Gu; Quach, Lien; Li, Wenjun; Lipsitz, Lewis A
2013-09-01
Outdoor fallers differ from indoor fallers substantially in demographics, lifestyle, health condition and physical function. Biomechanical predictors of outdoor falls have not been well characterized. Current validated measures of postural deficits, which describe only the overall postural behavior, are predictive of indoor falls but not outdoor falls. We hypothesized that a model-based description of postural muscle tone and reflexes, particularly during dual tasking, would predict outdoor falls. We tested whether postural stiffness and damping from an inverted pendulum model were predictive of future indoor and outdoor falls among older adults from the MOBILIZE Boston Study. The center of pressure data during standing were obtained from 717 participants aged 77.9±5.3 years. Participants stood barefoot with eyes open for 30s per trial, in two sets of five standing trials. One set included a serial subtractions task. Postural stiffness and damping values were determined from the postural sway data. After the postural measurements, falls were monitored prospectively using a monthly mail-in calendar over 6-36 months. Associations of postural measures with fall rates were determined using negative binomial regressions. After covariate adjustments, postural stiffness (p=0.02-0.05) and damping (p=0.007-0.1) were associated with lower outdoor falls risk, but not with indoor falls. Results were invariant by direction (anteroposterior versus mediolateral) or by condition (quiet standing versus dual task). Outdoor fall risk may be tied to postural control more so than indoor falls. Dual tasking is likely related to fall risk among older and sicker older adults, but not those relatively healthy. Copyright © 2013 Elsevier B.V. All rights reserved.
Kang, Hyun Gu; Quach, Lien; Li, Wenjun; Lipsitz, Lewis A.
2013-01-01
Outdoor fallers differ from indoor fallers substantially in demographics, lifestyle, health condition and physical function. Biomechanical predictors of outdoor falls have not been well characterized. Current validated measures of postural deficits, which describe only the overall postural behavior, are predictive of indoor falls but not outdoor falls. We hypothesized that a model-based description of postural muscle tone and reflexes, particularly during dual tasking, would predict outdoor falls. We tested whether postural stiffness and damping from an inverted pendulum model were predictive of future indoor and outdoor falls among older adults from the MOBILIZE Boston Study. The center of pressure data during standing were obtained from 717 participants aged 77.9±5.3 years. Participants stood barefoot with eyes open for 30 seconds per trial, in two sets of five standing trials. One set included a serial subtractions task. Postural stiffness and damping values were determined from the postural sway data. After the postural measurements, falls were monitored prospectively using a monthly mail-in calendar over 6-36 months. Associations of postural measures with fall rates were determined using negative binomial regressions. After covariate adjustments, postural stiffness (p=0.02-0.05) and damping (p=0.007-0.1) were associated with lower outdoor falls risk, but not with indoor falls. Results were invariant by direction (anteroposterior versus mediolateral) or by condition (quiet standing versus dual task). Outdoor fall risk may be tied to postural control more so than indoor falls. Dual tasking is likely related to fall risk among older and sicker older adults, but not those relatively healthy. PMID:23623606
Indoor environmental risk factors in young asthmatics: a case-control study.
Lindfors, A; Wickman, M; Hedlin, G; Pershagen, G; Rietz, H; Nordvall, S L
1995-11-01
One hundred and ninety three children with asthma and 318 controls aged 1-4 years were evaluated for atopic heredity and exposure to possible indoor risk factors for asthma-for example exposure to furred pets, tobacco smoke, and home dampness. A subgroup of cases were classified as cat and/or dog allergic on the basis of skin prick tests. Heredity for asthma was a significant risk factor (odds ratio (OR) 3.0, confidence interval (CI) 2.1 to 4.6). Environmental tobacco smoke was associated with an excess risk for asthma (OR 1.7, CI 1.1 to 2.3) and signs of home dampness tended to increase this risk (OR 1.3, CI 0.9 to 2.0). High dose exposure to cat and/or dog resulted in an increased risk only in asthma cases sensitised to cat and/or dog (OR 2.7, CI 1.0 to 7.3). A combination of high dose exposure to cat and/or dog, environmental tobacco smoke and damp housing was associated with an OR of 8.0 (CI 1.9 to 34.1). Raised indoor humidity has been shown to reflect low air exchange, which may also lead to increased doses of inhaled aeroallergens and tobacco smoke, and contribute to the interaction between the three risk factors.
Indoor environmental risk factors in young asthmatics: a case-control study.
Lindfors, A; Wickman, M; Hedlin, G; Pershagen, G; Rietz, H; Nordvall, S L
1995-01-01
One hundred and ninety three children with asthma and 318 controls aged 1-4 years were evaluated for atopic heredity and exposure to possible indoor risk factors for asthma-for example exposure to furred pets, tobacco smoke, and home dampness. A subgroup of cases were classified as cat and/or dog allergic on the basis of skin prick tests. Heredity for asthma was a significant risk factor (odds ratio (OR) 3.0, confidence interval (CI) 2.1 to 4.6). Environmental tobacco smoke was associated with an excess risk for asthma (OR 1.7, CI 1.1 to 2.3) and signs of home dampness tended to increase this risk (OR 1.3, CI 0.9 to 2.0). High dose exposure to cat and/or dog resulted in an increased risk only in asthma cases sensitised to cat and/or dog (OR 2.7, CI 1.0 to 7.3). A combination of high dose exposure to cat and/or dog, environmental tobacco smoke and damp housing was associated with an OR of 8.0 (CI 1.9 to 34.1). Raised indoor humidity has been shown to reflect low air exchange, which may also lead to increased doses of inhaled aeroallergens and tobacco smoke, and contribute to the interaction between the three risk factors. PMID:8554356
Norbäck, Dan; Cai, Gui-Hong
2011-10-01
There is little information on the indoor environment in hotels. Analysis of fungal DNA by quantitative PCR (qPCR) is a new method which can detect general and specific sequences. Dust was collected through swab sampling of door frames in 69 hotel rooms in 20 countries in Europe and Asia (2007-2009). Five sequences were detected by qPCR: total fungal DNA, Aspergillus and Penicillium DNA (Asp/Pen DNA), Aspergillus versicolor (A. versicolor DNA), Stachybotrys chartarum (S. chartarum DNA) and Streptomyces spp. (Streptomyces DNA). Associations were analysed by multiple linear regression. Total fungal DNA (GM = 1.08 × 10(8) cell equivalents m(-2); GSD = 6.36) and Asp/Pen DNA (GM = 1.79 × 10(7) cell equivalents m(-2); GSD = 10.12) were detected in all rooms. A. versicolor DNA, S. chartarum DNA and Streptomyces DNA were detected in 84%, 28% and 47% of the samples. In total, 20% of the rooms had observed dampness/mould, and 30% had odour. Low latitude (range 1.5-64.2 degrees) was a predictor of Asp/Pen DNA. Seaside location, lack of mechanical ventilation, and dampness or mould were other predictors of total fungal DNA and Asp/Pen DNA. Hotel ranking (Trip Advisor) or self-rated quality of the interior of the hotel room was a predictor of total fungal DNA, A. versicolor DNA and Streptomyces DNA. Odour was a predictor of S. chartarum DNA. In conclusion, fungal DNA in swab samples from hotel rooms was related to latitude, seaside location, ventilation, visible dampness and indoor mould growth. Hotels in tropical areas may have 10-100 times higher levels of common moulds such as Aspergillus and Penicillium species, as compared to a temperate climate zone.
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-01
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios—of open, tilted, and closed windows—were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor–indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor–indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows. PMID:29346318
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows.
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Röösli, Martin; Brink, Mark; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-18
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.
Wang, J; Engvall, K; Smedje, G; Nilsson, H; Norbäck, D
2017-07-01
In the Swedish Building Energy, Technical Status and Indoor environment study, a total of 1160 adults from 605 single-family houses answered a questionnaire on respiratory health. Building inspectors investigated the homes and measured temperature, air humidity, air exchange rate, and wood moisture content (in attic and crawl space). Moisture load was calculated as the difference between indoor and outdoor absolute humidity. Totally, 7.3% were smokers, 8.7% had doctor' diagnosed asthma, 11.2% current wheeze, and 9.5% current asthma symptoms. Totally, 50.3% had respiratory infections and 26.0% rhinitis. The mean air exchange rate was 0.36/h, and the mean moisture load 1.70 g/m 3 . Damp foundation (OR=1.79, 95% CI 1.16-2.78) was positively associated while floor constructions with crawl space (OR=0.49, 95% CI 0.29-0.84) was negatively associated with wheeze. Concrete slabs with overlying insulation (OR=2.21, 95% CI 1.24-3.92) and brick façade (OR=1.71, 95% CI 1.07-2.73) were associated with rhinitis. Moisture load was associated with respiratory infections (OR=1.21 per 1 g/m 3 , 95% CI 1.04-1.40) and rhinitis (OR=1.36 per 1 g/m 3 , 95% CI 1.02-1.83). Air exchange rate was associated with current asthma symptoms (OR=0.85 per 0.1/h, 95% CI 0.73-0.99). Living in homes with damp foundation, concrete slabs with overlying insulation, brick façade, low ventilation flow, and high moisture load are risk factors for asthma, rhinitis, and respiratory infections. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Vocal cord dysfunction related to water-damaged buildings.
Cummings, Kristin J; Fink, Jordan N; Vasudev, Monica; Piacitelli, Chris; Kreiss, Kathleen
2013-01-01
Vocal cord dysfunction (VCD) is the intermittent paradoxical adduction of the vocal cords during respiration, resulting in variable upper airway obstruction. Exposure to damp indoor environments is associated with adverse respiratory health outcomes, including asthma, but its role in the development of VCD is not well described. We describe the spectrum of respiratory illness in occupants of 2 water-damaged office buildings. The National Institute for Occupational Safety and Health conducted a health hazard evaluation that included interviews with managers, a maintenance officer, a remediation specialist who had evaluated the 2 buildings, employees, and consulting physicians. In addition, medical records and reports of building evaluations were reviewed. Diagnostic evaluations for VCD had been conducted at the Asthma and Allergy Center of the Medical College of Wisconsin. Two cases of VCD were temporally related to occupancy of water-damaged buildings. The patients experienced cough, chest tightness, dyspnea, wheezing, and hoarseness when in the buildings. Spirometry was normal. Methacholine challenge did not show bronchial hyperreactivity but did elicit symptoms of VCD and inspiratory flow-volume loop truncation. Direct laryngoscopy revealed vocal cord adduction during inspiration. Coworkers developed upper and lower respiratory symptoms; their diagnoses included sinusitis and asthma, consistent with recognized effects of exposure to indoor dampness. Building evaluations provided evidence of water damage and mold growth. VCD can occur with exposure to water-damaged buildings and should be considered in exposed patients with asthma-like symptoms. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendell, Mark J.
2015-06-01
This report briefly summarizes, based on recent review articles and selected more recent research reports, current scientific knowledge on two topics: assessing unhealthy levels of indoor D/M in homes and remediating home dampness-related problems to protect health. Based on a comparison of current scientific knowledge to that required to support effective, evidence-based, health-protective policies on home D/M, gaps in knowledge are highlighted, prior questions and research questions specified, and necessary research activities and approaches recommended.
Deng, Qihong; Lu, Chan; Ou, Cuiyun; Chen, Lv; Yuan, Hong
2016-06-01
Environmental factors have been found to be associated with allergic diseases, but it is unclear which environmental factor during which exposure window causes what kind of allergic diseases. We investigated association between exposure to some predominant outdoor and indoor environmental factors during preconceptional, prenatal, and postnatal periods and allergic diseases/symptoms in 2598 children in China. Children's lifetime incidence of allergic diseases and current prevalence of allergic symptoms and exposure to indoor new furniture/redecoration and mold/dampness was surveyed by a questionnaire. Exposure to outdoor air pollutants was estimated by the concentrations measured at air quality monitoring stations. Multiple logistic regression model was used to evaluate the associations between outdoor air pollutants and indoor environmental factors and allergic diseases (asthma, allergic rhinitis, and eczema) and symptoms (wheezing, night cough, and rhinitis-like). We found that preconceptional, prenatal, and postnatal exposure to outdoor industrial and traffic air pollutants were significantly associated with increase in the risk of childhood asthma, and also positively associated with allergic rhinitis and eczema. However, we cannot distinguish the effect of outdoor air pollutants and exposure windows because of their high correlations. New furniture was associated with eczema and allergic rhinitis during postnatal exposure, but redecoration associated with asthma and eczema during prenatal exposure. Indoor visible mold/damp stains was significant for eczema during prenatal exposure and asthma during postnatal exposure respectively, but window condensation was significant for all childhood allergic diseases during both prenatal and postnatal exposures. Allergic symptoms in children were found to be associated with exposure to indoor factors only. Associations between outdoor air pollutants and indoor environmental factors and childhood allergic diseases/symptoms were divergent and related to the timing of exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reducing vibration transfer from power plants by active methods
NASA Astrophysics Data System (ADS)
Kiryukhin, A. V.; Milman, O. O.; Ptakhin, A. V.
2017-12-01
The possibility of applying the methods of active damping of vibration and pressure pulsations for reducing their transfer from power plants into the environment, the seating, and the industrial premises are considered. The results of experimental works implemented by the authors on the active broadband damping of vibration and dynamic forces after shock-absorption up to 15 dB in the frequency band up to 150 Hz, of water pressure pulsations in the pipeline up to 20 dB in the frequency band up to 600 Hz, and of spatial low-frequency air noise indoors of a diesel generator at discrete frequency up to 20 dB are presented. It is shown that a reduction of vibration transfer through a vibration-isolating junction (expansion joints) of pipelines with liquid is the most complicated and has hardly been developed so far. This problem is essential for vibration isolation of power equipment from the seating and the environment through pipelines with water and steam in the power and transport engineering, shipbuilding, and in oil and gas pipelines in pumping stations. For improving efficiency, reducing the energy consumption, and decreasing the overall dimensions of equipment, it is advisable to combine the work of an active system with passive damping means, the use of which is not always sufficient. The executive component of the systems of active damping should be placed behind the vibration isolators (expansion joints). It is shown that the existence of working medium and connection of vibration with pressure pulsations in existing designs of pipeline expansion joints lead to growth of vibration stiffness of the expansion joint with the environment by two and more orders as compared with the static stiffness and makes difficulties for using the active methods. For active damping of vibration transfer through expansion joints of pipelines with a liquid, it is necessary to develop expansion joint structures with minimal connection of vibrations and pulsations and minimal vibration stiffness in the specified frequency range. The example of structure of such expansion joint and its test results are presented.
Molds are fungi that can be found both outdoors and indoors. They grow best in warm, damp and humid conditions. If ... spots in your house, you will probably get mold. Molds can cause health problems. Inhaling or touching ...
All about Allergies (For Parents)
... leaves or compost piles. Indoors, molds thrive in dark, poorly ventilated places such as bathrooms and damp ... or red eyes, this is called allergic conjunctivitis . (Dark circles that sometimes show up around the eyes ...
Maintaining Indoor Environmental Quality (IEQ) during Construction and Renovation
... and licensed contractors are required to conduct renovation. Biological Materials Chronic dampness from water intrusion leads to ... require special precautions prior to demolition to prevent biological dusts from dispersing in the occupied space. Another ...
Predictors of microbial agents in dust and respiratory health in the Ecrhs.
Tischer, Christina; Zock, Jan-Paul; Valkonen, Maria; Doekes, Gert; Guerra, Stefano; Heederik, Dick; Jarvis, Deborah; Norbäck, Dan; Olivieri, Mario; Sunyer, Jordi; Svanes, Cecilie; Täubel, Martin; Thiering, Elisabeth; Verlato, Giuseppe; Hyvärinen, Anne; Heinrich, Joachim
2015-05-02
Dampness and mould exposure have been repeatedly associated with respiratory health. However, less is known about the specific agents provoking or arresting health effects in adult populations. We aimed to assess predictors of microbial agents in mattress dust throughout Europe and to investigate associations between microbial exposures, home characteristics and respiratory health. Seven different fungal and bacterial parameters were assessed in mattress dust from 956 adult ECRHS II participants in addition to interview based home characteristics. Associations between microbial parameters and the asthma score and lung function were examined using mixed negative binomial regression and linear mixed models, respectively. Indoor dampness and pet keeping were significant predictors for higher microbial agent concentrations in mattress dust. Current mould and condensation in the bedroom were significantly associated with lung function decline and current mould at home was positively associated with the asthma score. Higher concentrations of muramic acid were associated with higher mean ratios of the asthma score (aMR 1.37, 95%CI 1.17-1.61). There was no evidence for any association between fungal and bacterial components and lung function. Indoor dampness was associated with microbial levels in mattress dust which in turn was positively associated with asthma symptoms.
Quality of indoor residential air and health
Dales, Robert; Liu, Ling; Wheeler, Amanda J.; Gilbert, Nicolas L.
2008-01-01
About 90% of our time is spent indoors where we are exposed to chemical and biological contaminants and possibly to carcinogens. These agents may influence the risk of developing nonspecific respiratory and neurologic symptoms, allergies, asthma and lung cancer. We review the sources, health effects and control strategies for several of these agents. There are conflicting data about indoor allergens. Early exposure may increase or may decrease the risk of future sensitization. Reports of indoor moulds or dampness or both are consistently associated with increased respiratory symptoms but causality has not been established. After cigarette smoking, exposure to environmental tobacco smoke and radon are the most common causes of lung cancer. Homeowners can improve the air quality in their homes, often with relatively simple measures, which should provide health benefits. PMID:18625986
Storrø, Ola; Oien, Torbjørn; Dotterud, Christian K; Jenssen, Jon A; Johnsen, Roar
2010-07-28
This study aimed to evaluate the impact of a primary prevention intervention program on risk behavior for allergic diseases among children up to 2 years of age. The setting was in ordinary pre- and postnatal primary health care in Trondheim, Norway. The Prevention of Allergy among Children in Trondheim, Norway (PACT) study invited all pregnant women and parents to children up to 2 years of age in the community to participate in a non-randomized, controlled, multiple life-style intervention study. Interventional topics was increased dietary intake of cod liver oil and oily fish for women during pregnancy and for infants during the first 2 years of life, reduced parental smoking and reduced indoor dampness. A control cohort was established prior to the intervention cohort with "follow up as usual". Questionnaires were completed in pregnancy, 6 weeks after birth and at 1 and 2 years of age. Trends in exposure and behavior are described. Intake of oily fish and cod liver oil increased statistically significantly among women and infants in the intervention cohort compared to the control cohort. There was a low postnatal smoking prevalence in both cohorts, with a trend towards a decreasing smoking prevalence in the control cohort. There was no change in indoor dampness or in behavior related to non- intervened life-style factors. The dietary intervention seemed to be successful. The observed reduced smoking behavior could not be attributed to the intervention program, and the latter had no effect on indoor dampness. (Current Controlled Trials registration number: ISRCTN28090297).
Fu, Lingyu; Zhang, Jianming; Jin, Lei; Zhang, Yao; Cui, Saisai; Chen, Meng
2018-03-01
The aim of this study was to evaluate new and previously hypothesized environmental risk factors and their interaction with rheumatoid arthritis (RA). Four hundred patients recently diagnosed with RA and 400 controls frequency-matched by gender and birth year using Propensity Score Matching (PSM) were selected from northern China. Investigation was performed using self-reported data from interviewer-administered surveys. Associations between exposure variables and risk of RA were evaluated using multifactor non-conditional logistic regression. It showed that damp localities, draft indoor, abdominal obesity (AO), and family history of RA among first-degree relatives were independent risk factors and drinking of milk was independent protective factors for RA. Besides these risk factors, in women, infrequent delivery times, early age at menopause, and late age at menarche were also independent risk factors for RA. Both the additive model and the multiplication model suggested that there was an interaction relationship between AO and damp localities (p < .001), and only the additive model suggested that there was interaction relationship between AO and no milk drinking (p < .001) in our study population. In women, there was interaction relationship between AO and damp localities (p < .001) and between AO and age at menopause (p < .001). In northern China, damp localities, draft indoor, AO, family history of RA among first-degree relatives, and no milk drinking may be important risk factors of RA patients.
Choi, Hyunok; Byrne, Sam; Larsen, Lisbeth Suldrup; Sigsgaard, Torben; Thorne, Peter S.; Larsson, Lennart; Sebastian, Aleksandra; Bornehag, Carl-Gustaf
2014-01-01
Background Qualitative reporting of home indoor moisture problems predicts respiratory diseases. However, causal agents underlying such qualitative markers remain unknown. Methods In the homes of 198 multiple allergic case children and 202 controls in Sweden, we cultivated culturable fungi by directly plating dust, and quantified(1–3, 1–6)-β-D-glucan, and ergosterol in dust samples from the child’s bedroom. We examined the relationship between these fungal agents and degree of parent or inspector reported home indoor dampness, and microbiological laboratory’s mold index. We also compared the concentrations of these agents between multiple allergic cases and healthy controls, as well as IgE-sensitization among cases. Results The concentrations of culturable fungal agents were comparable between houses with parent and inspector reported mold issues and those without. There were no differences in concentrations of the individual or the total summed culturable fungi, (1–3, 1–6)-β-D-glucan, and ergosterol between the controls and the multiple allergic case children, or individual diagnosis of asthma, rhinitis or eczema. Conclusion Culturable fungi, (1–3, 1–6)-β-D-glucan, and ergosterol in dust were not associated with qualitative markers of indoor dampness or mold or indoor humidity. Furthermore, these agents in dust samples were not associated with any health outcomes in the children. PMID:24016225
Norbäck, Dan; Lu, Chan; Wang, Juan; Zhang, Yinping; Li, Baizhan; Zhao, Zhuohui; Huang, Chen; Zhang, Xin; Qian, Hua; Sun, Yuexia; Sundell, Jan; Deng, Qihong
2018-06-01
Few data exist on asthma and rhinitis across China in relation to indoor and outdoor air pollution, climate and socioeconomic factors. The main aim was to study associations between asthma, rhinitis and current respiratory symptoms among pre-school children across China and selected indoor and outdoor exposure and indicators of socio-economic status (SES) in mutually adjusted models. Chinese children (3-6 yr.) (n = 39,782) were recruited from randomly selected day care centres in seven cities in China. Data on asthma, respiratory symptoms, rhinitis, indoor and outdoor exposure at home and SES were assessed by a parentally administered questionnaire. Lifetime mean ambient temperature, PM 10 , NO 2, and GDP per capita on city level were calculated. Totally 7.4% had ever doctors' diagnosed (DD) asthma and 8.7% DD-rhinitis, 19.7% had current wheeze, 45.0% rhinitis and 16.9% cough. DD-asthma was associated with ambient temperature (OR = 1.15, 95% CI 1.11-1.20 per °C), NO 2 (OR = 1.16, 95% CI 1.02-1.33 per 10 μg/m 3 ), indoor mould/dampness (OR = 1.25, 95% CI 1.13-1.39) and living near major roads (OR = 1.13, 95% CI 1.02-1.25). DD-rhinitis was associated with ambient temperature (OR = 1.07, 95% CI 1.05-1.10 per °C), NO 2 (OR = 1.20, 95% CI 1.09-1.32 per 10 μg/m 3 ), GDP (OR = 1.03, 95% CI 1.01-1.06 per 10,000 RenMinBi/year), indoor mould/dampness (OR = 1.23, 95% CI 1.11-1.35), passive smoking (OR = 1.11, 95% CI 1.01-1.21), and living near major roads (OR = 1.14, 95% CI 1.03-1.25). Children in suburban or rural areas, in larger families (≥5 persons) and with prenatal farm exposure had less DD-asthma and DD-rhinitis. Economic development level of the city, higher SES, ambient temperature, NO 2 , PM 10 , traffic air pollution and mould/dampness can be risk factors for asthma and rhinitis and respiratory symptoms among pre-school children in China. Breastfeeding, large family size and early-life farm exposure could be protective factors. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fungal pollution of indoor environments and its management.
Haleem Khan, A A; Mohan Karuppayil, S
2012-10-01
Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.
Fungal pollution of indoor environments and its management
Haleem Khan, A.A.; Mohan Karuppayil, S.
2012-01-01
Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health. PMID:23961203
JAAKKOLA, M S; LAITINEN, S; PIIPARI, R; UITTI, J; NORDMAN, H; HAAPALA, A-M; JAAKKOLA, J J K
2002-01-01
Immunoglobulin G (IgG) antibodies against microbes related to indoor dampness problems have been used as potential biomarkers of fungal exposure in clinical investigations. There is limited information on their relation to asthma. We conducted a population-based incident case–control study to assess the risk of asthma in relation to specific IgG antibodies to eight dampness-related microbes: Aspergillus fumigatus, A. versicolor, Cladosporium cladosporioides, Fusarium oxysporum, Sporobolomyces salmonicolor, Stachybotrys chartarum, Streptomyces albus and Trichoderma citrinoviride. We recruited systematically all new cases of asthma during a 2·5-year study period and randomly selected controls from a source population of adults 21–63 years of age living in the Pirkanmaa Hospital District, South Finland. The clinically diagnosed case series consisted of 521 adults with newly diagnosed asthma and the control series of 932 controls selected randomly from the source population. IgG antibodies were analysed with ELISA. An increased risk of developing asthma in adulthood was significantly related to IgG antibodies to T. citrinoviride, but not to the other moulds. There was no evidence of a dose–response relation between the IgG antibody level and the risk of asthma. T. citrinoviride may play a role in the aetiology of adult-onset asthma or serve as an indicator of other causal factors. PMID:12100029
Influence of indoor factors in dwellings on the development of childhood asthma.
Heinrich, Joachim
2011-01-01
Asthma has become the most common, childhood chronic disease in the industrialized world, and it is also increasing in developing regions. There are huge differences in the prevalence of childhood asthma across countries and continents, and there is no doubt that the prevalence of asthma was strongly increasing during the past decades worldwide. Asthma, as a complex disease, has a broad spectrum of potential determinants ranging from genetics to life style and environmental factors. Environmental factors are likely to be important in explaining the regional differences and the overall increasing trend towards asthma's prevalence. Among the environmental conditions, indoor factors are of particular interest because people spend more than 80% of their time indoors globally. Increasing prices for oil, gas and other sources of primary energy will further lead to better insulation of homes, and ultimately to reduced energy costs. This will decrease air exchange rates and will lower the dilution of indoor air mass with ambient air. Indoor air quality and potential health effects will therefore be an area for future research and for gaining a better understanding of asthma epidemics. This strategic review will summarize the current knowledge of the effects of a broad spectrum of indoor factors on the development of asthma in childhood in Western countries based on epidemiological studies. In conclusion, several epidemiological studies point out, that indoor factors might cause asthma in childhood. Stronger and more consistent findings are seen when exposure to these indoor factors is assessed by surrogates for the source of the actual toxicants. Measurement-based exposure assessments for several indoor factors are less common than using surrogates of the exposure. These studies, however, mainly showed heterogeneous results. The most consistent finding for an induction of asthma in childhood is related to exposure to environmental tobacco smoke, to living in homes close to busy roads, and in damp homes where are visible moulds at home. The causing agents of the increased risk of living in damp homes remained uncertain and needs clarification. Exposure to pet-derived allergens and house dust mites are very commonly investigated and thought to be related to asthma onset. The epidemiological evidence is not sufficient to recommend avoidance measures against pet and dust mites as preventive activities against allergies. More research is also needed to clarify the potential risk for exposure to volatile and semi-volatile organic compounds due to renovation activities, phthalates and chlorine chemicals due to cleaning. Copyright © 2010 Elsevier GmbH. All rights reserved.
Reflections on the history of indoor air science, focusing on the last 50 years.
Sundell, J
2017-07-01
The scientific articles and Indoor Air conference publications of the indoor air sciences (IAS) during the last 50 years are summarized. In total 7524 presentations, from 79 countries, have been made at Indoor Air conferences held between 1978 (49 presentations) and 2014 (1049 presentations). In the Web of Science, 26 992 articles on indoor air research (with the word "indoor" as a search term) have been found (as of 1 Jan 2016) of which 70% were published during the last 10 years. The modern scientific history started in the 1970s with a question: "did indoor air pose a threat to health as did outdoor air?" Soon it was recognized that indoor air is more important, from a health point of view, than outdoor air. Topics of concern were first radon, environmental tobacco smoke, and lung cancer, followed by volatile organic compounds, formaldehyde and sick building syndrome, house dust-mites, asthma and allergies, Legionnaires disease, and other airborne infections. Later emerged dampness/mold-associated allergies and today's concern with "modern exposures-modern diseases." Ventilation, thermal comfort, indoor air chemistry, semi-volatile organic compounds, building simulation by computational fluid dynamics, and fine particulate matter are common topics today. From their beginning in Denmark and Sweden, then in the USA, the indoor air sciences now show increasing activity in East and Southeast Asia. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Takaoka, Motoko; Suzuki, Kyoko; Norbäck, Dan
2017-08-01
To study associations between the school and home environment and current asthma, respiratory symptoms and airway infections among Japanese students. Japanese students (12-15 y) (N = 1048) in four schools responded to a questionnaire on respiratory health, allergy and the home environment. Temperature, relative air humidity (RH) and student density (students/m 2 floor area) was measured in the classrooms: dust was collected from floors and in classroom air and analysed for cat (Fel d 1) and dog (Can f 1) allergens. Health associations were analysed by multi-level logistic regression. Doctor's diagnosed asthma was common (13.4%), 8.8% reported cat allergy and 6.1% dog allergy. The median level in floor dust was 41 ng/g (IQR 23-92) for Fel d 1 and 101 ng/g (IQR 54-101) for Can f 1. The median level in air was 18.6 ng/ m 2 / day (IQR5.9-25.1) for Fel d 1 and 18.6 ng/ m 2 / day (IQR 6.0-13.3) for Can f 1. High RH, high student density and airborne cat allergen was associated with airway infections. In the home environment, recent indoor painting, new floor materials, odour, having cats as pets, window pane condensation in winter, and dampness in floor construction were associated with respiratory illness. High relative air humidity, high student density and airborne cat allergens at school may increase the risk of airway infections. Having cats as pets, chemical emissions from paint and new floor materials, odour and dampness can constitute domestic risk factors for respiratory symptoms while having dogs as pets could be protective.
Solomon, Gina M.; Hjelmroos-Koski, Mervi; Rotkin-Ellman, Miriam; Hammond, S. Katharine
2006-01-01
Background The hurricanes and flooding in New Orleans, Louisiana, in October and November 2005 resulted in damp conditions favorable to the dispersion of bioaerosols such as mold spores and endotoxin. Objective Our objective in this study was to assess potential human exposure to bioaerosols in New Orleans after the flooding of the city. Methods A team of investigators performed continuous airborne sampling for mold spores and endotoxin outdoors in flooded and nonflooded areas, and inside homes that had undergone various levels of remediation, for periods of 5–24 hr during the 2 months after the flooding. Results The estimated 24-hr mold concentrations ranged from 21,000 to 102,000 spores/m3 in outdoor air and from 11,000 to 645,000 spores/m3 in indoor air. The mean outdoor spore concentration in flooded areas was roughly double the concentration in nonflooded areas (66,167 vs. 33,179 spores/m3; p < 0.05). The highest concentrations were inside homes. The most common mold species were from the genera of Cladosporium and Aspergillus/Penicillium; Stachybotrys was detected in some indoor samples. The airborne endotoxin concentrations ranged from 0.6 to 8.3 EU (endo-toxin units)/m3 but did not vary with flooded status or between indoor and outdoor environments. Conclusions The high concentration of mold measured indoors and outdoors in the New Orleans area is likely to be a significant respiratory hazard that should be monitored over time. Workers and returning residents should use appropriate personal protective equipment and exposure mitigation techniques to prevent respiratory morbidity and long-term health effects. PMID:16966092
Air-Sense: indoor environment monitoring evaluation system based on ZigBee network
NASA Astrophysics Data System (ADS)
Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang
2017-08-01
In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.
Climate Change and Our Environment: The Effect on Respiratory and Allergic Disease
Barnes, Charles S.; Alexis, Neil E.; Bernstein, Jonathan A.; Cohn, John R.; Demain, Jeffrey G.; Horner, Elliott; Levetin, Estelle; Nel, Andre; Phipatanakul, Wanda
2013-01-01
Climate change is a constant and ongoing process. It is postulated that human activities have reached a point at which we are producing global climate change. This article provides suggestions to help the allergist/environmental physician integrate recommendations about improvements in outdoor and indoor air quality and the likely response to predicted alterations in the earth’s environment into their patient’s treatment plan. Many changes that affect respiratory disease are anticipated. Examples of responses to climate change include energy reduction retrofits in homes that could potentially affect exposure to allergens and irritants, more hot sunny days that increase ozone-related difficulties, and rises in sea level or altered rainfall patterns that increase exposure to damp indoor environments. Climate changes can also affect ecosystems, manifested as the appearance of stinging and biting arthropods in new areas. Higher ambient carbon dioxide concentrations, warmer temperatures, and changes in floristic zones could potentially increase exposure to ragweed and other outdoor allergens, whereas green practices such as composting can increase allergen and irritant exposure. Finally, increased energy costs may result in urban crowding and human source pollution, leading to changes in patterns of infectious respiratory illnesses. Improved governmental controls on airborne pollutants could lead to cleaner air and reduced respiratory diseases but will meet strong opposition because of their effect on business productivity. The allergy community must therefore adapt, as physician and research scientists always have, by anticipating the needs of patients and by adopting practices and research methods to meet changing environmental conditions. PMID:23687635
A View Indoors, Indoor Environment Division's e-Article Series
The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.
In search of a common European approach to a healthy indoor environment.
Adan, Olaf C G; Ng-A-Tham, Julie; Hanke, Wojtek; Sigsgaard, Torben; van den Hazel, Peter; Wu, Felicia
2007-06-01
Increasingly, policymakers in Europe and around the world are realizing the importance of healthy indoor environments for public health. Certain member states of the European Union (EU) have already achieved successes in improving indoor environmental quality, such as controlling certain contaminants (e.g., environmental tobacco smoke) or developing nationwide policies that address indoor air generally. However, a common European approach to achieving healthy indoor environments is desirable for several reasons including providing a broader recognition of the problem of unhealthy indoor air, setting a policy example for all 27 EU member states, and achieving greater public health equity across the different European nations. In this article we address the question "Why is it so difficult in the EU to develop a coherent approach on indoor environment?" We identify and describe four main barriers: a) the subsidiarity principle in EU policymaking, introducing decentralization of decision making to the member states; b) fragmentation of the topic of the indoor environment; c) the differences in climate and governance among different member states that make a common policy difficult; and d) economic issues. We discuss potential lessons and recommendations from EU and U.S. successes in achieving healthier indoor environments through various policy mechanisms.
Indoor Environment in Residential Prefabricated Buildings
NASA Astrophysics Data System (ADS)
Kraus, Michal; Juhásová Šenitková, Ingrid
2017-10-01
The contribution presents results of the experimental measurement of indoor air quality in residential prefabricated buildings. People spend about 90% of their life in the indoor environment of buildings. Hygrothermal parameters and indoor air quality are the essential component that define the quality of the indoor environment. The results of case study characterize the quality of the indoor environment of the ordinary occupants in housing unit of residential prefabricated building. A current problem of revitalized prefabricated buildings is inadequate air exchange and related thereto to poor indoor air quality. The experimental measurements were carried out just before and at the beginning of the heating season (from 1st October to 30th November 2016). Heating season was launched in the middle of experimental measurement. The wireless indoor sensor Elgato Eve Room was used for measurements. The obtained values of indoor air temperature [°C], relative humidity [%] and indoor air quality [ppm] are describe and analysis in this study. The results of the study indicate that the values of temperature and indoor air quality meet optimal levels during the experiment with nuances. The mean air temperature in the indoor environment is 22.43 °C. The temperature of the indoor environment is held at the optimum level (18-24 °C) for 94.50% time of the experimental measurements. In addition, the indoor air quality in the context of the content of harmful volatile organic compounds (VOCs) has been excellent for almost 91% time of the total experiment. However, the values of relative humidity were less than the optimum value nearly 40% of the total observed time. The mean 10-minutes values of relative humidity during the heating season is about 10% lower than the mean 10-minutes relative humidity before the heating season.
Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong
NASA Astrophysics Data System (ADS)
Lee, Shun-Cheng; Guo, Hai; Li, Wai-Ming; Chan, Lo-Yin
Indoor air quality in selected indoor environments in Hong Kong such as homes, offices, schools, shopping malls and restaurants were investigated. Average CO 2 levels and total bacteria counts in air-conditioned classrooms, shopping malls and restaurants were comparatively higher than those measured in occupied offices and homes. Elevated CO 2 levels exceeding 1000 ppm and total bacteria counts resulted from high occupancy combined with inadequate ventilation. Average PM 10 levels were usually higher indoors than outdoors in homes, shopping malls and restaurants. The highest indoor PM 10 levels were observed at investigated restaurants due to the presence of cigarette smoking and extensive use of gas stoves for cooking. The restaurants and shopping malls investigated had higher formaldehyde levels than other indoor environments when building material, smoking and internal renovation work were present. Volatile organic compounds (VOCs) in both indoor and outdoor environments mainly resulted from vehicle exhaust emissions. It was observed that interior decoration work and the use of industrial solvents in an indoor environment could significantly increase the indoor levels of VOCs.
Vapor Transport to Indoor Environments
The indoor environment is an important microenvironment for human exposure to chemicals, both because people spend most of their time indoors and because chemicals are often at higher concentrations indoors versus outdoors. This chapter reviews the major components in estimating ...
Norbäck, D; Zock, J-P; Plana, E; Heinrich, J; Tischer, C; Jacobsen Bertelsen, R; Sunyer, J; Künzli, N; Villani, S; Olivieri, M; Verlato, G; Soon, A; Schlünssen, V; Gunnbjörnsdottir, M I; Jarvis, D
2017-09-01
We studied dampness and mold in homes in relation to climate, building characteristics and socio-economic status (SES) across Europe, for 7127 homes in 22 centers. A subsample of 3118 homes was inspected. Multilevel analysis was applied, including age, gender, center, SES, climate, and building factors. Self-reported water damage (10%), damp spots (21%), and mold (16%) in past year were similar as observed data (19% dampness and 14% mold). Ambient temperature was associated with self-reported water damage (OR=1.63 per 10°C; 95% CI 1.02-2.63), damp spots (OR=2.95; 95% CI 1.98-4.39), and mold (OR=2.28; 95% CI 1.04-4.67). Precipitation was associated with water damage (OR=1.12 per 100 mm; 95% CI 1.02-1.23) and damp spots (OR=1.11; 95% CI 1.02-1.20). Ambient relative air humidity was not associated with indoor dampness and mold. Older buildings had more dampness and mold (P<.001). Manual workers reported less water damage (OR=0.69; 95% CI 0.53-0.89) but more mold (OR=1.27; 95% CI 1.03-1.55) as compared to managerial/professional workers. There were correlations between reported and observed data at center level (Spearman rho 0.61 for dampness and 0.73 for mold). In conclusion, high ambient temperature and precipitation and high building age can be risk factors for dampness and mold in homes in Europe. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Brown, Terry; Dassonville, Claire; Derbez, Mickael; Ramalho, Olivier; Kirchner, Severine; Crump, Derrick; Mandin, Corinne
2015-07-01
To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Norbäck, Dan; Lu, Chan; Zhang, Yinping; Li, Baizhan; Zhao, Zhuohui; Huang, Chen; Zhang, Xin; Qian, Hua; Sundell, Jan; Deng, Qihong
2017-06-01
There is some evidence that dampness, mould and cockroaches can increase the risk of respiratory infections in children but few studies exist from China on this topic. Aim To study associations between domestic early life exposure to biological indoor factors (dampness, mould, cats, dogs, rats, cockroaches), cleaning habits and common cold among pre-school children across China. Children aged 3-6years (n=39,782) were recruited from randomly selected day care centres in seven cities in China. Data on common cold and prenatal and postnatal exposure to dampness, mould, windowpane condensation in wintertime (WPC), cats, dogs, cockroaches and rats were assessed by a parentally administered questionnaire. Data on annual ambient temperature and PM 10 was assessed on city level. Associations between high frequency (>5 colds per year) and long duration (≥2weeks) of common colds in the past year and exposure were calculated by multilevel logistic regression. A total of 9.2% had a high frequency and 11.9% had long duration of common cold. Exposure to mould (OR=1.38, 95% CI 1.24-1.53) and WPC (OR 1.23, 95%CI 1.13-1.33) at birth was associated with frequent common cold. Exposure to dogs at birth was associated with long duration of common cold. (OR=1.22, 95% CI 1.06-1.41). Exposure to mould (OR=1.36, 95% CI 1.22-1.54), WPC (OR=1.27, 95%CI 1.17-1.39) and water leakage (OR 1.34, 95% CI 1.20-1.49) in the current home was associated with frequent common cold. Presence of cockroaches were positively (OR=1.12, 95% CI 1.02-1.24) and presence of rats (OR=0.86, 95% CI 0.77-0.96) negatively associated with high frequency of common cold. Daily cleaning was negatively associated with frequent common cold (OR=0.89, 95% CI 0.81-0.97). Similar associations for mould, WPC, cockroaches and rats were found for long duration. Ambient PM 10 (OR=1.21, 95% CI 1.21-1.35 per 10μg/m 3 ) and temperature (OR=1.13, 95% CI 1.06-1.35 °C) on city level were associated with high frequency of common cold. Associations between cat keeping and high frequency of common cold were found only in southern China. Associations with cockroaches were stronger in northern China. Associations with dampness and mould were the same in the north and south. Indoor mould, water damage, windowpane condensation, cockroaches and keeping cats or dogs as pets can be risk factors for common cold while daily cleaning can be protective factor. PM 10 and a warmer climate zone can be other risk factors for common cold. Copyright © 2017 Elsevier Ltd. All rights reserved.
Associations between fungal species and water-damaged building materials.
Andersen, Birgitte; Frisvad, Jens C; Søndergaard, Ib; Rasmussen, Ib S; Larsen, Lisbeth S
2011-06-01
Fungal growth in damp or water-damaged buildings worldwide is an increasing problem, which has adverse effects on both the occupants and the buildings. Air sampling alone in moldy buildings does not reveal the full diversity of fungal species growing on building materials. One aim of this study was to estimate the qualitative and quantitative diversity of fungi growing on damp or water-damaged building materials. Another was to determine if associations exist between the most commonly found fungal species and different types of materials. More than 5,300 surface samples were taken by means of V8 contact plates from materials with visible fungal growth. Fungal identifications and information on building material components were analyzed using multivariate statistic methods to determine associations between fungi and material components. The results confirmed that Penicillium chrysogenum and Aspergillus versicolor are the most common fungal species in water-damaged buildings. The results also showed Chaetomium spp., Acremonium spp., and Ulocladium spp. to be very common on damp building materials. Analyses show that associated mycobiotas exist on different building materials. Associations were found between (i) Acremonium spp., Penicillium chrysogenum, Stachybotrys spp., Ulocladium spp., and gypsum and wallpaper, (ii) Arthrinium phaeospermum, Aureobasidium pullulans, Cladosporium herbarum, Trichoderma spp., yeasts, and different types of wood and plywood, and (iii) Aspergillus fumigatus, Aspergillus melleus, Aspergillus niger, Aspergillus ochraceus, Chaetomium spp., Mucor racemosus, Mucor spinosus, and concrete and other floor-related materials. These results can be used to develop new and resistant building materials and relevant allergen extracts and to help focus research on relevant mycotoxins, microbial volatile organic compounds (MVOCs), and microparticles released into the indoor environment.
Influence of relative humidity on VOC concentrations in indoor air.
Markowicz, Pawel; Larsson, Lennart
2015-04-01
Volatile organic compounds (VOCs) may be emitted from surfaces indoors leading to compromised air quality. This study scrutinized the influence of relative humidity (RH) on VOC concentrations in a building that had been subjected to water damage. While air samplings in a damp room at low RH (21-22%) only revealed minor amounts of 2-ethylhexanol (3 μg/m(3)) and 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB, 8 μg/m(3)), measurements performed after a rapid increase of RH (to 58-75%) revealed an increase in VOC concentrations which was 3-fold for 2-ethylhexanol and 2-fold for TXIB. Similar VOC emission patterns were found in laboratory analyses of moisture-affected and laboratory-contaminated building materials. This study demonstrates the importance of monitoring RH when sampling indoor air for VOCs in order to avoid misleading conclusions from the analytical results.
Evolution of the indoor biome.
Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R
2015-04-01
Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.
EVALUATION OF AIR PURIFICATION DEVICES FOR CONTROL OF INDOOR PM
Because people spend most of their time indoors (89%), the indoor environment is a primary determinant of particle exposure. The indoor environment is especially an important determinant for the very young, the very old, and those with underlying cardiopulmonary disease because...
Climate change and our environment: the effect on respiratory and allergic disease.
Barne, Charles; Alexis, Neil E; Bernstein, Jonathan A; Cohn, John R; Demain, Jeffrey G; Horner, Elliot; Levetin, Estelle; Nei, Andre; Phipatanakul, Wanda
2013-03-01
Climate change is a constant and ongoing process. It is postulated that human activities have reached a point at which we are producing global climate change. It provides suggestions to help the allergist/environmental physician integrate recommendations about improvements in outdoor and indoor air quality and the likely response to predicted alterations in the earth's environment into his or her patient's treatment plan. It incorporates references retrieved from Pub Med searches for topics, including:climate change, global warming, global climate change, greenhouse gasses, air pollution, particulates, black carbon, soot and sea level, as well as references contributed by the individual authors. Many changes that affect respiratory disease are anticipated.Examples of responses to climate change include energy reduction retrofits in homes that could potentially affect exposure to allergens and irritants, more hot sunny days that increase ozone-related difficulties, and rises in sea level or altered rainfall patterns that increase exposure to damp indoor environments.Climate changes can also affect ecosystems, manifested as the appearance of stinging and biting arthropods in new areas.Higher ambient carbon dioxide concentrations, warmer temperatures, and changes in floristic zones could potentially increase exposure to ragweed and other outdoor allergens,whereas green practices such as composting can increase allergen and irritant exposure. Finally, increased energy costs may resultin urban crowding and human source pollution, leading to changes in patterns of infectious respiratory illnesses. Improved governmental controls on airborne pollutants could lead to cleaner air and reduced respiratory diseases but will meet strong opposition because of their effect on business productivity. The allergy community must therefore adapt, as physician and research scientists always have, by anticipating the needs of patients and by adopting practices and research methods to meet changing environmental conditions.
Rethinking Indoor Localization Solutions Towards the Future of Mobile Location-Based Services
NASA Astrophysics Data System (ADS)
Guney, C.
2017-11-01
Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user's location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.
A review of polychlorinated biphenyls (PCBs) pollution in indoor air environment.
Dai, Qizhou; Min, Xia; Weng, Mili
2016-10-01
Polychlorinated biphenyls (PCBs) were widely used in industrial production due to the unique physical and chemical properties. As a kind of persistent organic pollutants, the PCBs would lead to environment pollution and cause serious problems for human health. Thus, they have been banned since the 1980s due to the environment pollution in the past years. Indoor air is the most direct and important environment medium to human beings; thus, the PCBs pollution research in indoor air is important for the protection of human health. This paper introduces the industrial application and potential harm of PCBs, summarizes the sampling, extracting, and analytical methods of environment monitoring, and compares the indoor air levels of urban areas with those of industrial areas in different countries according to various reports. This paper can provide a basic summary for PCBs pollution control in the indoor air environment. The review of PCBs pollution in indoor air in China is still limited. In this paper, we introduce the industrial application and potential harm of PCBs, summarize the sampling, extracting, and analytical methods of environment monitoring, and compare the indoor air levels of urban areas with industrial areas in different countries according to various reports.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kong, S.H.; Chung, K.S.; Park, J.S.
1999-07-01
Currently, there are many researches on the analysis of indoor environment in Sokkuram Cave Temple. However, there is not enough researches about an experimental study on the dome's indoor environment in Sokkuram Cave Temple using a miniature model. The purpose of this investigation is to measure and analyze characteristics of indoor environment such as relative humidity, dry bulb temperature and air velocity in the miniature model of Sokkuram Cave dome during winter season.
2017-06-01
implement human following on a mobile robot in an indoor environment . B. FUTURE WORK Future work that could be conducted in the realm of this thesis...FEASIBILITY OF CONDUCTING HUMAN TRACKING AND FOLLOWING IN AN INDOOR ENVIRONMENT USING A MICROSOFT KINECT AND THE ROBOT OPERATING SYSTEM by...FEASIBILITY OF CONDUCTING HUMAN TRACKING AND FOLLOWING IN AN INDOOR ENVIRONMENT USING A MICROSOFT KINECT AND THE ROBOT OPERATING SYSTEM 5. FUNDING NUMBERS
Study on indoor thermal environment in winter for rural residences in Yulin region
NASA Astrophysics Data System (ADS)
Yanjun, Li; Weixiao, Han
2018-02-01
Yulin region is located in the northern part of Shaanxi Province, China. The winter here is very cold and it has a long duration. In this paper, a rural residence which was located in Yulin region was taken as a study object. Indoor thermal environment of the rural residence were tested, including indoor air temperature and air relative humidity. Then, test data were analyzed. It was summarized that indoor thermal environment of test room can not fully meet human thermal comfort needs, and some tactics of regulation building thermal environment were proposed. This research contributes to improvement of indoor thermal environment for local rural residences and it provides reference for rural residences in other cold regions.
The effect of the indoor environment on the fate of organic chemicals in the urban landscape.
Cousins, Anna Palm
2012-11-01
To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.
Calculating Least Risk Paths in 3d Indoor Space
NASA Astrophysics Data System (ADS)
Vanclooster, A.; De Maeyer, Ph.; Fack, V.; Van de Weghe, N.
2013-08-01
Over the last couple of years, research on indoor environments has gained a fresh impetus; more specifically applications that support navigation and wayfinding have become one of the booming industries. Indoor navigation research currently covers the technological aspect of indoor positioning and the modelling of indoor space. The algorithmic development to support navigation has so far been left mostly untouched, as most applications mainly rely on adapting Dijkstra's shortest path algorithm to an indoor network. However, alternative algorithms for outdoor navigation have been proposed adding a more cognitive notion to the calculated paths and as such adhering to the natural wayfinding behaviour (e.g. simplest paths, least risk paths). These algorithms are currently restricted to outdoor applications. The need for indoor cognitive algorithms is highlighted by a more challenged navigation and orientation due to the specific indoor structure (e.g. fragmentation, less visibility, confined areas…). As such, the clarity and easiness of route instructions is of paramount importance when distributing indoor routes. A shortest or fastest path indoors not necessarily aligns with the cognitive mapping of the building. Therefore, the aim of this research is to extend those richer cognitive algorithms to three-dimensional indoor environments. More specifically for this paper, we will focus on the application of the least risk path algorithm of Grum (2005) to an indoor space. The algorithm as proposed by Grum (2005) is duplicated and tested in a complex multi-storey building. The results of several least risk path calculations are compared to the shortest paths in indoor environments in terms of total length, improvement in route description complexity and number of turns. Several scenarios are tested in this comparison: paths covering a single floor, paths crossing several building wings and/or floors. Adjustments to the algorithm are proposed to be more aligned to the specific structure of indoor environments (e.g. no turn restrictions, restricted usage of rooms, vertical movement) and common wayfinding strategies indoors. In a later stage, other cognitive algorithms will be implemented and tested in both an indoor and combined indoor-outdoor setting, in an effort to improve the overall user experience during navigation in indoor environments.
Emerging developments in the standardized chemical characterization of indoor air quality.
Nehr, Sascha; Hösen, Elisabeth; Tanabe, Shin-Ichi
2017-01-01
Despite the fact that the special characteristics of indoor air pollution make closed environments quite different from outdoor environments, the conceptual ideas for assessing air quality indoors and outdoors are similar. Therefore, the elaboration of International Standards for air quality characterization in view of controlling indoor air quality should resort to this common basis. In this short review we describe the possibilities of standardization of tools dedicated to indoor air quality characterization with a focus on the tools permitting to study the indoor air chemistry. The link between indoor exposure and health as well as the critical processes driving the indoor air quality are introduced. Available International Standards for the assessment of indoor air quality are depicted. The standards comprise requirements for the sampling on site, the analytical procedures, and the determination of material emissions. To date, these standardized procedures assure that indoor air, settled dust and material samples are analyzed in a comparable manner. However, existing International Standards exclusively specify conventional, event-driven target-screening using discontinuous measurement methods for long-lived pollutants. Therefore, this review draws a parallel between physico-chemical processes in indoor and outdoor environments. The achievements in atmospheric sciences also improve our understanding of indoor environments. The community of atmospheric scientists can be both ideal and supporter for researchers in the area of indoor air quality characterization. This short review concludes with propositions for future standardization activities for the chemical characterization of indoor air quality. Future standardization efforts should focus on: (i) the elaboration of standardized measurement methods and measurement strategies for online monitoring of long-lived and short-lived pollutants, (ii) the assessment of the potential and the limitations of non-target screening, (iii) the paradigm shift from event-driven investigations to systematic approaches to characterize indoor environments, and (iv) the development of tools for policy implementation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Teachers and Healthy Indoor School Environments
Teachers can be powerful advocates for creating healthy indoor environments, including improving school indoor air quality (IAQ). As they are on the front lines, teachers can perceive when IAQ changes affect students and themselves.
Mold growth on gypsum wallboard--a summary of three techniques.
Menetrez, M Y; Foarde, K K; Webber, T D; Dean, T R; Betancourt, D A
2009-01-01
Reducing occupant exposure to mold growing on damp gypsum wallboard and controlling mold contamination in the indoor environment was studied through 1) delineation of environmental conditions required to promote and avoid mold growth and 2) efficacy testing of antimicrobial products, specifically cleaners and paints, on gypsum wallboard (GWB) surfaces. The effects of moisture and relative humidity (RH) on mold growth and transport are important in avoiding and eliminating problems. These effects have been demonstrated on GWB and are discussed in this article for use as control guidance. The authors discuss the efficacy of antimicrobial cleaners and paints to remove, eliminate, or control mold growth on GWB. Research to control Stachybotrys chartarum growth using 13 separate antimicrobial cleaners and nine varieties of antimicrobial paint on contaminated GWB was performed in laboratory testing. GWB surfaces were subjected to high RH. GWB control measures are summarized and combined, and the antimicrobial product results are explained.
Indoor molds and lung function in healthy adults.
Hernberg, Samu; Sripaiboonkij, Penpatra; Quansah, Reginald; Jaakkola, Jouni J K; Jaakkola, Maritta S
2014-05-01
Indoor mold exposure is common worldwide and constitutes an important health problem. There are very few studies assessing the relation between mold exposure and lung function levels among non-asthmatic adults. Our objective was to assess the relations between dampness and mold exposures at home and at work and lung function. In particular, we elaborated the importance of different exposure indicators. In a population-based study, 269 non-asthmatic adults from South Finland answered a questionnaire on indoor dampness and mold exposures at home or at work and other factors potentially influencing lung function, and performed spirometry. Multiple linear regression model was applied to study the relations between exposures and spirometric lung function levels. In linear regression adjusting for confounding, FEV1 level was reduced on average 200 ml related to mold odor at home (effect estimate -0.20, 95% CI -0.60 to 0.21) and FVC level was reduced on average 460 ml (-0.46, -0.95 to 0.03) respectively. Exposure to mold odor at home or at work or both was related to reduced FEV1 (-0.15, -0.42 to 0.12) and FVC (-0.22, -0.55 to 0.11) levels. Women had on average 510 ml reduced FEV1 levels (-0.51, -1.0 to 0.03) and 820 ml reduced FVC levels (-0.82, -1.4 to -0.20) related to mold odor exposure at home. Mold odor exposure was related to lower lung function levels among non-asthmatic adults, especially among women. Copyright © 2014 Elsevier Ltd. All rights reserved.
The use of modern technologies in carbon dioxide monitoring
NASA Astrophysics Data System (ADS)
Komínek, Petr; Weyr, Jan; Hirš, Jiří
2017-12-01
Indoor environment has huge influence on person's health and overall comfort. It is of great importance that we realize how essential indoor air quality is, considering we spend on average as much as 90% of our time indoors. There are many factors that affect indoor air quality: specifically, inside air temperature, relative humidity, and odors to name the most important factors. One of the key factors indicating indoor air quality is carbon dioxide (CO2) level. The CO2 levels, measured in prefab apartment buildings, indicates substantial indoor air quality issues. Therefore, a proper education of the occupants is of utmost importance. Also, great care should be directed towards technical and technological solutions that would ensure meeting the normative indoor environment criteria, especially indoor air CO2 levels. Thanks to the implementation of new emerging autonomous technologies, such as Internet of Things (IoT), monitoring in real-time is enhanced. An area where IoT plays a major role is in the monitoring of indoor environment. IoT technology (e.g. smart meters and sensors) provide awareness of information about the quality of indoor environment. There is a huge potential for influencing behaviour of the users. Through the web application, it is possible to educate people and ensure fresh air supply.
Performance Evaluation of Indoor Environment towards Sustainability for Higher Educational Buildings
ERIC Educational Resources Information Center
Khalil, Natasha; Husin, Husrul Nizam; Wahab, Lilawati Ab; Kamal, Kamarul Syahril; Mahat, Noorsaidi
2011-01-01
The indoor environmental factors considered in higher educational building must be determined in order to meet the user's requirement. Disruption of indoor environment may constitute to reduce occupants' efficiencies and their learning process and activities. But the question is, how to ensure that the provision of indoor environmental aspects…
Influenza transmission during extreme indoor conditions in a low-resource tropical setting
NASA Astrophysics Data System (ADS)
Tamerius, James; Ojeda, Sergio; Uejio, Christopher K.; Shaman, Jeffrey; Lopez, Brenda; Sanchez, Nery; Gordon, Aubree
2017-04-01
Influenza transmission occurs throughout the planet across wide-ranging environmental conditions. However, our understanding of the environmental factors mediating transmission is evaluated using outdoor environmental measurements, which may not be representative of the indoor conditions where influenza is transmitted. In this study, we examined the relationship between indoor environment and influenza transmission in a low-resource tropical population. We used a case-based ascertainment design to enroll 34 households with a suspected influenza case and then monitored households for influenza, while recording indoor temperature and humidity data in each household. We show that the indoor environment is not commensurate with outdoor conditions and that the relationship between indoor and outdoor conditions varies significantly across homes. We also show evidence of influenza transmission in extreme indoor environments. Specifically, our data suggests that indoor environments averaged 29 °C, 18 g/kg specific humidity, and 68 % relative humidity across 15 transmission events observed. These indoor settings also exhibited significant temporal variability with temperatures as high as 39 °C and specific and relative humidity increasing to 22 g/kg and 85 %, respectively, during some transmission events. However, we were unable to detect differences in the transmission efficiency by indoor temperature or humidity conditions. Overall, these results indicate that laboratory studies investigating influenza transmission and virus survival should increase the range of environmental conditions that they assess and that observational studies investigating the relationship between environment and influenza activity should use caution using outdoor environmental measurements since they can be imprecise estimates of the conditions that mediate transmission indoors.
Influenza transmission during extreme indoor conditions in a low-resource tropical setting.
Tamerius, James; Ojeda, Sergio; Uejio, Christopher K; Shaman, Jeffrey; Lopez, Brenda; Sanchez, Nery; Gordon, Aubree
2017-04-01
Influenza transmission occurs throughout the planet across wide-ranging environmental conditions. However, our understanding of the environmental factors mediating transmission is evaluated using outdoor environmental measurements, which may not be representative of the indoor conditions where influenza is transmitted. In this study, we examined the relationship between indoor environment and influenza transmission in a low-resource tropical population. We used a case-based ascertainment design to enroll 34 households with a suspected influenza case and then monitored households for influenza, while recording indoor temperature and humidity data in each household. We show that the indoor environment is not commensurate with outdoor conditions and that the relationship between indoor and outdoor conditions varies significantly across homes. We also show evidence of influenza transmission in extreme indoor environments. Specifically, our data suggests that indoor environments averaged 29 °C, 18 g/kg specific humidity, and 68 % relative humidity across 15 transmission events observed. These indoor settings also exhibited significant temporal variability with temperatures as high as 39 °C and specific and relative humidity increasing to 22 g/kg and 85 %, respectively, during some transmission events. However, we were unable to detect differences in the transmission efficiency by indoor temperature or humidity conditions. Overall, these results indicate that laboratory studies investigating influenza transmission and virus survival should increase the range of environmental conditions that they assess and that observational studies investigating the relationship between environment and influenza activity should use caution using outdoor environmental measurements since they can be imprecise estimates of the conditions that mediate transmission indoors.
Potential Nationwide Improvements in Productivity and Health from Better Indoor Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, W.J.; Rosenfeld, A.H.
1998-05-01
Theoretical considerations and empirical data suggest that existing technologies and procedures can improve indoor environments in a manner that significantly increases productivity and health. Existing literature contains moderate to strong evidence that characteristics of buildings and indoor environments significantly influence rates of respiratory disease, allergy and asthma symptoms, sick building symptoms, and worker performance. While there is considerable uncertainty in our estimates of the magnitudes of productivity gains that may be obtained by providing better indoor environments, the projected gains are very large. For the U.S., we estimate potential annual savings and productivity gains of $6 to $19 billion frommore » reduced respiratory disease, $1 to $4 billion from reduced allergies and asthma, $10 to $20 billion from reduced sick building syndrome symptoms, and $12 to $125 billion from direct improvements in worker performance that are unrelated to health. In two example calculations, the potential financial benefits of improving indoor environments exceed costs by a factor of 8 and 14. Productivity gains that are quantified and demonstrated could serve as a strong stimulus for energy efficiency measures that simultaneously improve the indoor environment.« less
Potential nationwide improvements in productivity and health from better indoor environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, W.J.; Rosenfeld, A.H.
1998-07-01
Theoretical considerations and empirical data suggest that existing technologies and procedures can improve indoor environments in a manner that significantly increases productivity and health. Existing literature contains moderate to strong evidence that characteristics of buildings and indoor environments significantly influence rates of respiratory disease, allergy and asthma symptoms, sick building symptoms, and worker performance. While there is considerable uncertainty in their estimates of the magnitudes of productivity gains that may be obtained by providing better indoor environments, the projected gains are very large. For the US, the authors estimate potential annual savings and productivity gains of $6 to $19 billionmore » from reduced respiratory disease, $1 to $4 billion from reduced allergies and asthma, $10 to $20 billion from reduced sick building syndrome symptoms, and $12 to $125 billion from direct improvements in worker performance that are unrelated to health. In two example calculations, the potential financial benefits of improving indoor environments exceed costs by a factor of 8 and 14. Productivity gains that are quantified and demonstrated could serve as a strong stimulus for energy efficiency measures that simultaneously improve the indoor environment.« less
Healthy Indoor Environment Protocols for Home Energy Upgrades
This page contains the EPA-developed Healthy Indoor Environment Protocols for Home Energy Upgrades, a PDF guide that provides a set of best practices for improving indoor air quality in conjunction with energy upgrade work in homes.
Associations between Fungal Species and Water-Damaged Building Materials ▿
Andersen, Birgitte; Frisvad, Jens C.; Søndergaard, Ib; Rasmussen, Ib S.; Larsen, Lisbeth S.
2011-01-01
Fungal growth in damp or water-damaged buildings worldwide is an increasing problem, which has adverse effects on both the occupants and the buildings. Air sampling alone in moldy buildings does not reveal the full diversity of fungal species growing on building materials. One aim of this study was to estimate the qualitative and quantitative diversity of fungi growing on damp or water-damaged building materials. Another was to determine if associations exist between the most commonly found fungal species and different types of materials. More than 5,300 surface samples were taken by means of V8 contact plates from materials with visible fungal growth. Fungal identifications and information on building material components were analyzed using multivariate statistic methods to determine associations between fungi and material components. The results confirmed that Penicillium chrysogenum and Aspergillus versicolor are the most common fungal species in water-damaged buildings. The results also showed Chaetomium spp., Acremonium spp., and Ulocladium spp. to be very common on damp building materials. Analyses show that associated mycobiotas exist on different building materials. Associations were found between (i) Acremonium spp., Penicillium chrysogenum, Stachybotrys spp., Ulocladium spp., and gypsum and wallpaper, (ii) Arthrinium phaeospermum, Aureobasidium pullulans, Cladosporium herbarum, Trichoderma spp., yeasts, and different types of wood and plywood, and (iii) Aspergillus fumigatus, Aspergillus melleus, Aspergillus niger, Aspergillus ochraceus, Chaetomium spp., Mucor racemosus, Mucor spinosus, and concrete and other floor-related materials. These results can be used to develop new and resistant building materials and relevant allergen extracts and to help focus research on relevant mycotoxins, microbial volatile organic compounds (MVOCs), and microparticles released into the indoor environment. PMID:21531835
Indoor navigation by image recognition
NASA Astrophysics Data System (ADS)
Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man
2017-07-01
With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.
Microbial Resistant Test Method Development
Because humans spend most of their time in the indoor environment, environmental analysis of the quality of indoor air has become an important research topic. A major component of the aerosol in the indoor environment consists of biological particles, called bioaerosols, and fur...
MANAGING EXPOSURE TO INDOOR AIR POLLUTANTS IN RESIDENTIAL AND OFFICE ENVIRONMENTS
The paper discusses the factors to be considered in managing indoor air pollutants in residential and office environments to reduce occupant exposures. Techniques for managing indoor air pollution sources include: source elimination, substitution, modification, and pretreatment a...
THE ALLERGENIC POTENTIAL OF INDOOR AIR FUNGAL CONTAMINANTS
ABSTRACT
The indoor environment has increased in importance to children's health with children now spending more than 90% of their time indoors. Molds are an important component of this environment and have been associated with exacerbation of asthma. Their contribution t...
NASA Astrophysics Data System (ADS)
Wichmann, J.; Lind, T.; Nilsson, M. A.-M.; Bellander, T.
2010-11-01
In developed nations people spend about 90% of their time indoors. The relationship between indoor and outdoor air pollution levels is important for the understanding of the health effects of outdoor air pollution. Although other studies describe both the outdoor and indoor atmospheric environment, few excluded a priori major indoor sources, measured the air exchange rate, included more than one micro-environment and included the presence of human activity. PM 2.5, soot, NO 2 and the air exchange rate were measured during winter and summer indoors and outdoors at 18 homes (mostly apartments) of 18 children (6-11-years-old) and also at the six schools and 10 pre-schools that the children attended. The three types of indoor environments were free of environmental tobacco smoke and gas appliances, as the aim was to asses to what extent PM 2.5, soot and NO 2 infiltrate from outdoors to indoors. The median indoor and outdoor PM 2.5 levels were 8.4 μg m -3 and 9.3 μg m -3, respectively. The median indoor levels for soot and NO 2 were 0.66 m -1 × 10 -5 and 10.0 μg m -3, respectively. The respective outdoor levels were 0.96 m -1 × 10 -5 and 12.4 μg m -3. The median indoor/outdoor (I/O) ratios were 0.93, 0.76 and 0.92 for PM 2.5, soot and NO 2, respectively. Their infiltration factors were influenced by the micro-environment, ventilation type and air exchange rate, with aggregated values of 0.25, 0.55 and 0.64, respectively. Indoor and outdoor NO 2 levels were strongly associated ( R2 = 0.71), followed by soot ( R2 = 0.50) and PM 2.5 ( R2 = 0.16). In Stockholm, the three major indoor environments occupied by children offer little protection against combustion-related particles and gases in the outdoor air. Outdoor PM 2.5 seems to infiltrate less, but indoor sources compensate.
Potts, James F; Rona, Roberto J; Oyarzun, Manuel J; Amigo, Hugo; Bustos, Patricia
2008-04-01
We assessed the effects of indoor risk factors, including smoking, on different types of cough and on cough and wheeze in combination. Our sample was composed of 1232 men and women residing in a semirural area of Chile. We used a standardized questionnaire, sensitization to 8 allergens, and bronchial hyperresponsiveness to methacholine to assess cough and wheeze characteristics. Information was gathered on dampness, mold, ventilation, heating, housing quality, smoking, and environmental tobacco smoke exposure. Most exposures were associated with cough alone or cough in combination with wheeze. Smoking, past smoking, and environmental tobacco smoke exposure were strongly associated with dry cough and wheeze. The use of coal for heating was associated with dry cough. Leaks, mold, and lack of kitchen ventilation were associated with cough and wheeze. Nocturnal cough and productive cough were associated with specific types of sensitization, but dry cough was not. Productive cough was associated with hyperresponsiveness to methacholine. Several different types of indoor exposures, including environmental tobacco smoke exposure, are important contributors to morbidity associated with cough and wheeze. A vigorous preventive strategy designed to lower exposures to indoor risk factors would lower rates of respiratory morbidity.
Indoor risk factors for cough and their relation to wheeze and sensitization in Chilean young adults
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potts, J.F.; Rona, R.J.; Oyarzun, M.J.
2008-04-15
We assessed the effects of indoor risk factors, including smoking, on different types of cough and on cough and wheeze in combination. Our sample was composed of 1232 men and women residing in a semi-rural area of Chile. We used a standardized questionnaire, sensitization to 8 allergens, and bronchial hyperresponsiveness to methacholine to assess cough and wheeze characteristics. Information was gathered on dampness, mold, ventilation, heating, housing quality, smoking, and environmental tobacco smoke exposure. Most exposures were associated with cough alone or cough in combination with wheeze. Smoking, past smoking, and environmental tobacco smoke exposure were strongly associated with drymore » cough and wheeze. The use of coal for heating was associated with dry cough. Leaks, mold, and lack of kitchen ventilation were associated with cough and wheeze. Nocturnal cough and productive cough were associated with specific types of sensitization, but dry cough was not. Productive cough was associated with hyperresponsiveness to methacholine. Several different types of indoor exposures, including environmental tobacco smoke exposure, are important contributors to morbidity associated with cough and wheeze. A vigorous preventive strategy designed to lower exposures to indoor risk factors would lower rates of respiratory morbidity.« less
Lewinska, Anna M; Hoof, Jakob B; Peuhkuri, Ruut H; Rode, Carsten; Lilje, Osu; Foley, Matthew; Trimby, Patrick; Andersen, Birgitte
2016-10-01
Fungal growth in indoor environments is associated with many negative health effects. Many studies focus on brown- and white-rot fungi and their effect on wood, but there is none that reveals the influence of soft-rot fungi, such as Stachybotrys spp. and Chaetomium spp., on the structure of building materials such as plywood and gypsum wallboard. This study focuses on using micro-computed tomography (microCT) to investigate changes of the structure of plywood and gypsum wallboard during fungal degradation by S. chartarum and C. globosum. Changes in the materials as a result of dampness and fungal growth were determined by measuring porosity and pore shape via microCT. The results show that the composition of the building material influenced the level of penetration by fungi as shown by scanning electron microscopy (SEM). Plywood appeared to be the most affected, with the penetration of moisture and fungi throughout the whole thickness of the sample. Conversely, fungi grew only on the top cardboard in the gypsum wallboard and they did not have significant influence on the gypsum wallboard structure. The majority of the observed changes in gypsum wallboard occurred due to moisture. This paper suggests that the mycelium distribution within building materials and the structural changes, caused by dampness and fungal growth, depend on the type of the material. Copyright © 2016 Elsevier B.V. All rights reserved.
Douwes, J; van der Sluis, B; Doekes, G; van Leusden, F; Wijnands, L; van Strien, R; Verhoeff, A; Brunekreef, B
1999-03-01
Epidemiologic studies have demonstrated an association between indoor fungal growth and respiratory symptoms. However, in only a few studies was fungal exposure actually measured. The purpose of this study was to evaluate the measurement by enzyme immunoassay of extracellular polysaccharides of Aspergillus and Penicillium species (EPS-Asp/Pen ) in house dust as a marker for fungal exposure and to study the relations between EPS-Asp/Pen levels and home dampness and respiratory symptoms in children. Extracts of house dust samples from bedroom and living room floors and mattresses from homes of 31 children with chronic respiratory symptoms and 29 children with no chronic respiratory symptoms were analyzed for EPS-Asp/Pen. EPS-Asp/Pen were readily detectable (40 to 46,513 nanogram equivalent/g dust) in 161 house dust extracts, with highest concentrations in living room floor dust. EPS-Asp/Pen levels were 2 to 3 times higher on carpeted floors than on smooth floors. EPS-Asp/Pen were significantly correlated with total culturable fungi (r = 0.3 to 0.5) and with house dust mite allergens (r = 0.3 to 0.5). EPS-Asp/Pen levels in living room floor dust were positively associated with occupant-reported home dampness. This was not observed for EPS-Asp/Pen in bedroom floor and mattress dust. EPS-Asp/Pen levels in living room floor dust were positively associated with respiratory symptoms. EPS-Asp/Pen in bedroom floor and mattress dust showed a reversed association with respiratory symptoms, possibly because of allergen-avoidance measures taken in the bedroom. The enzyme immunoassay for fungal EPS-Asp/Pen may be a useful method for exposure assessment of indoor fungi.
INDOOR FUNGAL CONTAMINANTS: ASSESSING THE ALLERGIC POTENTIAL
The indoor environment has increased in importance to children's health with children now spending more than 90% of their time indoors. Molds are an important component of this environment and have been associated with exacerbation of asthma as well as a number of other health e...
Indoor-Outdoor Detection Using a Smart Phone Sensor.
Wang, Weiping; Chang, Qiang; Li, Qun; Shi, Zesen; Chen, Wei
2016-09-22
In the era of mobile internet, Location Based Services (LBS) have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL) has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users' current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM) communication cellular base station's signal strength in different environments, and identified the users' current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.
Human physiological responses to wooden indoor environment.
Zhang, Xi; Lian, Zhiwei; Wu, Yong
2017-05-15
Previous studies are mainly focused on non-wooden environments, whereas few are concerned with wooden ones. How wooden indoor environments impact the physiology of the occupants is still unclear. The purpose of this study was to explore the distinct physiological responses to wooden and non-wooden indoor environments, assessed by physiological parameters tests including blood pressure, electrocardiogram measurements, electro-dermal activity, oxyhemoglobin saturation, skin temperature, and near distance vision. Twenty healthy adults participated in this experiment, and their physiological responses were evaluated in a 90minute investigation. The results illustrated that; less tension and fatigue were generated in the wooden rooms than in the non-wooden rooms when the participants did their work. In addition, the study also found that the wooden environments benefit the autonomic nervous system, respiratory system, and visual system. Moreover, wooden rooms play a valuable role in physiological regulation and ease function especially after a consecutive period of work. These results provide an experimental basis to support that wooden environment is beneficial to indoor occupants than the non-wooden indoor environment. Copyright © 2017 Elsevier Inc. All rights reserved.
Protano, Carmela; Owczarek, Malgorzata; Antonucci, Arianna; Guidotti, Maurizio; Vitali, Matteo
2017-07-01
The aim of this research is to evaluate the ability of transplanted lichen Pseudovernia (P). furfuracea to biomonitor and bioaccumulate in urban indoor environments. The elements As, Cd, Cr, Cu, Hg, Ni and Pb and 12 selected polycyclic aromatic hydrocarbons (PAHs) were used to assess P. furfuracea as a biomonitoring tool for the indoor air quality of school environments. To achieve this purpose, lichen samples were exposed for 2 months in the outdoor and indoor environments of five school settings located in urban and rural areas. The results demonstrated that transplanted lichen P. furfuracea is a suitable biomonitoring tool for metals and PAHs in indoor settings and can discriminate between different levels of air pollution related to urbanisation and indoor conditions, such as those characterised by school environments. A transplanted lichen biomonitoring strategy is cost-effective, "green", educational for attending children and less "invasive" than traditional air sampling methods. The feasibility of indoor monitoring by P. furfuracea is a relevant finding and could be a key tool to improve air quality monitoring programmes in school scenarios and thus focus on health prevention interventions for children, who are one of the most susceptible groups in the population.
Kaunelienė, Violeta; Meišutovič-Akhtarieva, Marija; Martuzevičius, Dainius
2018-05-08
With the introduction of novel and potentially less polluting nicotine containing products to the market, the impacts of their usage to indoor air quality as opposed to conventional pollution sources must be reviewed and considered. This review study aimed to comparatively analyse changes in indoor air quality as the consequence of tobacco heating system (THS) generated pollution against general indoor air quality in various micro-environments, especially with combustion-based pollution sources present. Indoor concentrations of formaldehyde, acetaldehyde, benzene, toluene, nicotine and PM 2.5 were reviewed and compared; concentrations of other harmful and potentially harmful substances (HPHCs) were discussed. Generally, the usage of THS has been associated with lower or comparable indoor air pollutant concentrations compared against other conventional indoor sources or environments, in most cases distinguishable above background, thus potentially being associated with health effects at prolonged exposures as any other artificial air pollution source. In the controlled environment the use of THS (as well as an electronic cigarette) resulted in the lowest concentrations of formaldehyde, benzene, toluene, PM 2.5, among majority researched pollution sources (conventional cigarettes, waterpipe, incense, mosquito coils). The exposure to significantly higher pollution levels of benzene, toluene, and formaldehyde occurred in public environments, especially transport micro-environments. Such low levels of conventionally-assessed indoor pollutants resulting from the use of new nicotine containing products raise challenges for epidemiological studies of second-hand exposure to THS aerosol in real-life environments. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
The indoor environment has not been fully incorporated into the environmental justice dialogue. To inform strategies to reduce disparities, we developed a framework to identify the individual and place-based drivers of indoor environment quality. We reviewed empirical evidence...
Morawska, L; Ayoko, G A; Bae, G N; Buonanno, G; Chao, C Y H; Clifford, S; Fu, S C; Hänninen, O; He, C; Isaxon, C; Mazaheri, M; Salthammer, T; Waring, M S; Wierzbicka, A
2017-11-01
It has been shown that the exposure to airborne particulate matter is one of the most significant environmental risks people face. Since indoor environment is where people spend the majority of time, in order to protect against this risk, the origin of the particles needs to be understood: do they come from indoor, outdoor sources or both? Further, this question needs to be answered separately for each of the PM mass/number size fractions, as they originate from different sources. Numerous studies have been conducted for specific indoor environments or under specific setting. Here our aim was to go beyond the specifics of individual studies, and to explore, based on pooled data from the literature, whether there are generalizable trends in routes of exposure at homes, schools and day cares, offices and aged care facilities. To do this, we quantified the overall 24h and occupancy weighted means of PM 10 , PM 2.5 and PN - particle number concentration. Based on this, we developed a summary of the indoor versus outdoor origin of indoor particles and compared the means to the WHO guidelines (for PM 10 and PM 2.5 ) and to the typical levels reported for urban environments (PN). We showed that the main origins of particle metrics differ from one type of indoor environment to another. For homes, outdoor air is the main origin of PM 10 and PM 2.5 but PN originate from indoor sources; for schools and day cares, outdoor air is the source of PN while PM 10 and PM 2.5 have indoor sources; and for offices, outdoor air is the source of all three particle size fractions. While each individual building is different, leading to differences in exposure and ideally necessitating its own assessment (which is very rarely done), our findings point to the existence of generalizable trends for the main types of indoor environments where people spend time, and therefore to the type of prevention measures which need to be considered in general for these environments. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Nakagawa, M.; Akano, K.; Kobayashi, T.; Sekiguchi, Y.
2017-09-01
Image-based virtual reality (VR) is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS) positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, William J.
2000-04-01
Theoretical considerations and empirical data suggest that existing technologies and procedures can improve indoor environments in a manner that significantly increases productivity and health. Existing literature contains moderate to strong evidence that characteristics of buildings and indoor environments significantly influence rates of communicable respiratory illness, allergy and asthma symptoms, sick building symptoms, and worker performance. While there is considerable uncertainty in the estimates of the magnitudes of productivity gains that may be obtained by providing better indoor environments, the projected gains are very large. For the U.S., the estimated potential annual savings and productivity gains are $6 to $14 billionmore » from reduced respiratory disease, $2 to $4 billion from reduced allergies and asthma, $10 to $30 billion from reduced sick building syndrome symptoms, and $20 to $160 billion from direct improvements in worker performance that are unrelated to health. Productivity gains that are quantified and demonstrated could serve as a strong stimulus for energy efficiency measures that simultaneously improve the indoor environment.« less
Indoor air quality in public utility environments-a review.
Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena
2017-04-01
Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendell, Mark J.
This report briefly summarizes, based on recent review articles and selected more recent research reports, current scientific knowledge on two topics: assessing unhealthy levels of indoor D/M in homes and remediating home dampness-related problems to protect health. Based on a comparison of current scientific knowledge to that required to support effective, evidence-based, health-protective policies on home D/M, gaps in knowledge are highlighted, prior questions and research questions specified, and necessary research activities and approaches recommended.
Kuwahara, Y; Kondoh, J; Tatara, K; Azuma, E; Nakajima, T; Hashimoto, M; Komachi, Y
2001-03-01
Airway allergic diseases, such as bronchial asthma and allergic rhinitis, have increased, especially in urban areas. These diseases are characterized by airway inflammation with enhanced eosinophil activity, and the risk of disease development has been shown to increase with the prevalence of atopy. Questionnaires were administered to 426 healthy adult women aged 30-74 years, living in an urban area of Osaka, Japan, to survey individual living environments and airway allergic symptoms such as cough, sputum, and wheezing. Moreover, serum house-dust-mite (Dermatophagoides pteronyssinus, [Der p])-specific immunoglobulin E (IgE) and serum eosinophil cationic protein (ECP) were examined by radioimmunoassay, and the atopic status (atopic sensitization) and enhanced eosinophil activity were assessed as Der p-specific IgE RAST scores of 2-6 and ECP levels of more than 10 ng/ml, respectively. Intensive use of electric air conditioners in hot weather (odds ratio: 2.07 [95% CI: 1.11-3.87]) and mold proliferation in the kitchen (2.77 [1.34-5.73]) significantly increased the risk of atopic sensitization. Poor home ventilation and family smoking appeared to be positively but not significantly associated with atopic sensitization. Personal smoking and intensive use of the air conditioner appeared to be positively related to enhanced eosinophil activity. Atopic status showed significant involvement in the development of wheezing, and the development of cough was significantly associated with enhanced eosinophil activity. The results suggest that some urban styles of living are involved in atopic sensitization and enhanced eosinophil activity in the Japanese urban population, probably due to living conditions, such as indoor dampness and poor home ventilation, caused by tight insulation, which increase exposure to indoor air pollutants, such as respirable mite allergens and tobacco smoke.
Indoor air quality and health problems associated with damp floor coverings.
Tuomainen, Anneli; Seuri, Markku; Sieppi, Anne
2004-04-01
To study the relationship between a high incidence of bronchial asthma among employees working in an office building and an indoor air problem related to the degradation of polyvinyl chloride (PVC) floor coverings in the building. The indoor air measurements and results of renovations are also described. Employees' symptoms were surveyed by a questionnaire, and the incidence of asthma was calculated from the medical records for 1997-2000. The quality of indoor air was assessed by microbial sampling and by investigation of the building for possible moisture damage. Indoor air was sampled for volatile organic compounds (VOCs) through Tenax adsorbent tubes. In situ volatile emission measurements from the concrete floor were performed via the field and laboratory emission cell (FLEC) method. In an office with approximately 150 employees, eight new cases of asthma were found in 4 years. In addition, the workers complained of respiratory, conjunctival and nasal symptoms. Emissions indicating the degradation of plastic floor coverings (e.g. 2-ethyl-1-hexanol, 1-butanol) were found in the indoor air and floor material samples. The plastic floor coverings, adhesives and the levelling layers were carefully removed from 12 rooms. The VOCs had diffused into the underlying concrete slabs. The concrete was warmed to remove the diffused VOCs from these areas. After the repairs the concentrations of the VOCs indicating the degradation of PVC, decreased, as did the prevalence of the employees' symptoms and several asthma patients' need for medication. The workers in the office building complained of several respiratory, conjunctival and dermal symptoms. The incidence of adult-onset asthma was approximately nine-times higher than that among Finns employed in similar work. The most probable single cause of the indoor air problem was the degradation of the plastic floor coverings.
Chen, Rong; Sung, Wen-Pei; Chang, Hung-Chang; Chi, Yi-Rou
2013-01-01
A human life demand set to emerge in the future is the achievement of sustainability by maintaining a comfortable indoor environment without excessive reliance on energy-consuming air conditioners. The major research processes in this study are: (1) measuring indoor air quality and thermal comfort to evaluate the comfort of an indoor environment; (2) implementing questionnaire survey analysis to explore people's environmental self-perceptions and conducting a meta-analysis of the measurement results for air quality and physical aspects; and (3) constructing an indoor monitoring and management system. The experimental and analysis results of this research reveal that most of the office occupants preferred a cooler environment with a lower temperature. Additionally, because the summers in Taiwan are humid and hot, the occupants of an indoor space tend to feel uncomfortable because of the high humidity and poor indoor air quality. Therefore, Variable Air Volume (VAV), two air intakes, and exhaust plant are installed to improve indoor environment. After improvement, a lower temperature (approximately 21.2–23.9°C) indirectly reduces humidity, thereby making the occupants comfortable. Increasing air velocity to 0.1 ~ 0.15 m/s, the carbon dioxide concentrations decrease below the requirement of the WHO. Ninety-five percent of the workers corresponded to the standard comfort zone after this improvement. PMID:24311976
How to Create Healthy Indoor Environments in Schools
ERIC Educational Resources Information Center
Rhodes, Diane; Di Nella, Frank
2012-01-01
A green and healthy indoor environment should be a fundamental concern in the place where kids learn and grow. Good indoor air quality (IAQ) has been shown to have positive effects on student and staff productivity, performance, comfort and attendance. Conversely, poor IAQ in classrooms--caused by mold and moisture issues, problems with HVAC…
ERIC Educational Resources Information Center
Raiford, Regina
2001-01-01
Discusses the relationship between indoor air quality and productivity and a three-year research project to measure productivity within an educational setting. Also discusses research showing the impact of good indoor air quality on increasing productivity. Ten ways to manage asthma in a school environment are highlighted. (GR)
Takaro, Tim K; Scott, James A; Allen, Ryan W; Anand, Sonia S; Becker, Allan B; Befus, A Dean; Brauer, Michael; Duncan, Joanne; Lefebvre, Diana L; Lou, Wendy; Mandhane, Piush J; McLean, Kathleen E; Miller, Gregory; Sbihi, Hind; Shu, Huan; Subbarao, Padmaja; Turvey, Stuart E; Wheeler, Amanda J; Zeng, Leilei; Sears, Malcolm R; Brook, Jeffrey R
2015-01-01
The Canadian Healthy Infant Longitudinal Development birth cohort was designed to elucidate interactions between environment and genetics underlying development of asthma and allergy. Over 3600 pregnant mothers were recruited from the general population in four provinces with diverse environments. The child is followed to age 5 years, with prospective characterization of diverse exposures during this critical period. Key exposure domains include indoor and outdoor air pollutants, inhalation, ingestion and dermal uptake of chemicals, mold, dampness, biological allergens, pets and pests, housing structure, and living behavior, together with infections, nutrition, psychosocial environment, and medications. Assessments of early life exposures are focused on those linked to inflammatory responses driven by the acquired and innate immune systems. Mothers complete extensive environmental questionnaires including time-activity behavior at recruitment and when the child is 3, 6, 12, 24, 30, 36, 48, and 60 months old. House dust collected during a thorough home assessment at 3-4 months, and biological specimens obtained for multiple exposure-related measurements, are archived for analyses. Geo-locations of homes and daycares and land-use regression for estimating traffic-related air pollution complement time-activity-behavior data to provide comprehensive individual exposure profiles. Several analytical frameworks are proposed to address the many interacting exposure variables and potential issues of co-linearity in this complex data set.
2016-01-01
Two foundational methods for estimating the total economic burden of disease are cost of illness (COI) and willingness to pay (WTP). WTP measures the full cost to society, but WTP estimates are difficult to compute and rarely available. COI methods are more often used but less likely to reflect full costs. This paper attempts to estimate the full economic cost (2014$) of illnesses resulting from exposure to dampness and mold using COI methods and WTP where the data is available. A limited sensitivity analysis of alternative methods and assumptions demonstrates a wide potential range of estimates. In the final estimates, the total annual cost to society attributable to dampness and mold is estimated to be $3.7 (2.3–4.7) billion for allergic rhinitis, $1.9 (1.1–2.3) billion for acute bronchitis, $15.1 (9.4–20.6) billion for asthma morbidity, and $1.7 (0.4–4.5) billion for asthma mortality. The corresponding costs from all causes, not limited to dampness and mold, using the same approach would be $24.8 billion for allergic rhinitis, $13.5 billion for acute bronchitis, $94.5 billion for asthma morbidity, and $10.8 billion for asthma mortality. PMID:27313630
Assessment of indoor air problems at work with a questionnaire
Reijula, K; Sundman-Digert, C
2004-01-01
Aims: To assess the extent of indoor air problems in office environments in Finland. Methods: Complaints and symptoms related to the indoor environment experienced by office workers were collected from 122 workplaces in 1996–99 by using the modified Indoor Air Questionnaire established by the Finnish Institute of Occupational Health. Altogether 11 154 employees took part in the survey. Results: The most common problems were dry air (35% of the respondents), stuffy air (34%), dust or dirt in the indoor environment (25%), and draught (22%). The most common work related symptoms were irritated, stuffy, or runny nose (20%), itching, burning, or irritation of the eyes (17%), and fatigue (16%). Women reported indoor air problems and work related symptoms more often than men. Allergic persons and smokers reported indoor air problems more often, and experienced work related symptoms more often than non-allergic persons and non-smokers. Conclusions: The complaints and work related symptoms associated with indoor air problems were common in office workers. The present questionnaire is a suitable tool for the occupational health personnel in investigating indoor air problems and the data of the survey can be used as a reference when the results of a survey at work are being analysed. PMID:14691270
NASA Astrophysics Data System (ADS)
Rivas, I.; Viana, M.; Moreno, T.; Bouso, L.; Pandolfi, M.; Alvarez-Pedrerol, M.; Forns, J.; Alastuey, A.; Sunyer, J.; Querol, X.
2015-04-01
Infiltration of outdoor-sourced particles into indoor environments in 39 schools in Barcelona was assessed during school hours. Tracers of road traffic emissions (NO2, Equivalent Black Carbon (EBC), Ultrafine Particles (UFP), Sb), secondary inorganic aerosols (SO42-, NO3-, NH4+) and a number of PM2.5 trace elements showed median indoor/outdoor (I/O) ratios ≤ 1, indicating that outdoor sources importantly contributed to indoor concentrations. Conversely, OC and mineral components had I/O ratios>1. Different infiltration factors were found for traffic and secondary components (0.31-0.75 and 0.50-0.92, cold and warm season respectively), with maxima corresponding to EBC and Cd. Higher concentrations of indoor-generated particles were observed when closed windows hindered dispersion (cold season). Building age was not a major determinant of indoor levels. Neither were the window's material, except for NO2 (with an increase of 8 μg m-3 for wood framed windows) and the mineral components (also dependent on the presence of sand in a distance <20 m) that reach the indoor environment via soil adhering to footwear with their dispersion being more barred by Aluminium/PVC framed windows than the wooden ones. Enlarged indoor concentrations of some trace elements suggest the presence of indoor sources that should be further investigated in order to achieve a healthier school indoor environment.
Transmission of Airborne Bacteria across Built Environments and Its Measurement Standards: A Review.
Fujiyoshi, So; Tanaka, Daisuke; Maruyama, Fumito
2017-01-01
Human health is influenced by various factors including microorganisms present in built environments where people spend most of their lives (approximately 90%). It is therefore necessary to monitor and control indoor airborne microbes for occupational safety and public health. Most studies concerning airborne microorganisms have focused on fungi, with scant data available concerning bacteria. The present review considers papers published from 2010 to 2017 approximately and factors affecting properties of indoor airborne bacteria (communities and concentration) with respect to temporal perspective and to multiscale interaction viewpoint. From a temporal perspective, bacterial concentrations in built environments change depending on numbers of human occupancy, while properties of bacterial communities tend to remain stable. Similarly, the bacteria found in social and community spaces such as offices, classrooms and hospitals are mainly associated with human occupancy. Other major sources of indoor airborne bacteria are (i) outdoor environments, and (ii) the building materials themselves. Indoor bacterial communities and concentrations are varied with varying interferences by outdoor environment. Airborne bacteria from the outdoor environment enter an indoor space through open doors and windows, while indoor bacteria are simultaneously released to the outer environment. Outdoor bacterial communities and their concentrations are also affected by geographical factors such as types of land use and their spatial distribution. The bacteria found in built environments therefore originate from any of the natural and man-made surroundings around humans. Therefore, to better understand the factors influencing bacterial concentrations and communities in built environments, we should study all the environments that humans contact as a single ecosystem. In this review, we propose the establishment of a standard procedure for assessing properties of indoor airborne bacteria using four factors: temperature, relative humidity (RH), air exchange rate, and occupant density, as a minimum requirement. We also summarize the relevant legislation by country. Choice of factors to measure remain controversial are discussed.
Transmission of Airborne Bacteria across Built Environments and Its Measurement Standards: A Review
Fujiyoshi, So; Tanaka, Daisuke; Maruyama, Fumito
2017-01-01
Human health is influenced by various factors including microorganisms present in built environments where people spend most of their lives (approximately 90%). It is therefore necessary to monitor and control indoor airborne microbes for occupational safety and public health. Most studies concerning airborne microorganisms have focused on fungi, with scant data available concerning bacteria. The present review considers papers published from 2010 to 2017 approximately and factors affecting properties of indoor airborne bacteria (communities and concentration) with respect to temporal perspective and to multiscale interaction viewpoint. From a temporal perspective, bacterial concentrations in built environments change depending on numbers of human occupancy, while properties of bacterial communities tend to remain stable. Similarly, the bacteria found in social and community spaces such as offices, classrooms and hospitals are mainly associated with human occupancy. Other major sources of indoor airborne bacteria are (i) outdoor environments, and (ii) the building materials themselves. Indoor bacterial communities and concentrations are varied with varying interferences by outdoor environment. Airborne bacteria from the outdoor environment enter an indoor space through open doors and windows, while indoor bacteria are simultaneously released to the outer environment. Outdoor bacterial communities and their concentrations are also affected by geographical factors such as types of land use and their spatial distribution. The bacteria found in built environments therefore originate from any of the natural and man-made surroundings around humans. Therefore, to better understand the factors influencing bacterial concentrations and communities in built environments, we should study all the environments that humans contact as a single ecosystem. In this review, we propose the establishment of a standard procedure for assessing properties of indoor airborne bacteria using four factors: temperature, relative humidity (RH), air exchange rate, and occupant density, as a minimum requirement. We also summarize the relevant legislation by country. Choice of factors to measure remain controversial are discussed. PMID:29238327
Polluted air--outdoors and indoors.
Myers, I; Maynard, R L
2005-09-01
Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend their interests into the environmental field and to focus on this important area.
Lucattini, Luisa; Poma, Giulia; Covaci, Adrian; de Boer, Jacob; Lamoree, Marja H; Leonards, Pim E G
2018-06-01
As many people spend a large part of their life indoors, the quality of the indoor environment is important. Data on contaminants such as flame retardants, pesticides and plasticizers are available for indoor air and dust but are scarce for consumer products such as computers, televisions, furniture, carpets, etc. This review presents information on semi-volatile organic compounds (SVOCs) in consumer products in an attempt to link the information available for chemicals in indoor air and dust with their indoor sources. A number of 256 papers were selected and divided among SVOCs found in consumer products (n = 57), indoor dust (n = 104) and air (n = 95). Concentrations of SVOCs in consumer products, indoor dust and air are reported (e.g. PFASs max: 13.9 μg/g in textiles, 5.8 μg/kg in building materials, 121 ng/g in house dust and 6.4 ng/m 3 in indoor air). Most of the studies show common aims, such as human exposure and risk assessment. The main micro-environments investigated (houses, offices and schools) reflect the relevance of indoor air quality. Most of the studies show a lack of data on concentrations of chemicals in consumer goods and often only the presence of chemicals is reported. At the moment this is the largest obstacle linking chemicals in products to chemicals detected in indoor air and dust. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Particle size distribution and air pollution patterns in three urban environments in Xi'an, China.
Niu, Xinyi; Guinot, Benjamin; Cao, Junji; Xu, Hongmei; Sun, Jian
2015-10-01
Three urban environments, office, apartment and restaurant, were selected to investigate the indoor and outdoor air quality as an inter-comparison in which CO2, particulate matter (PM) concentration and particle size ranging were concerned. In this investigation, CO2 level in the apartment (623 ppm) was the highest among the indoor environments and indoor levels were always higher than outdoor levels. The PM10 (333 µg/m(3)), PM2.5 (213 µg/m(3)), PM1 (148 µg/m(3)) concentrations in the office were 10-50% higher than in the restaurant and apartment, and the three indoor PM10 levels all exceeded the China standard of 150 µg/m(3). Particles ranging from 0.3 to 0.4 µm, 0.4 to 0.5 µm and 0.5 to 0.65 µm make largest contribution to particle mass in indoor air, and fine particles number concentrations were much higher than outdoor levels. Outdoor air pollution is mainly affected by heavy traffic, while indoor air pollution has various sources. Particularly, office environment was mainly affected by outdoor sources like soil dust and traffic emission; apartment particles were mainly caused by human activities; restaurant indoor air quality was affected by multiple sources among which cooking-generated fine particles and the human steam are main factors.
NASA Astrophysics Data System (ADS)
Wang, Ruozhu; Liu, Pengda; Qian, Yongmei
2018-02-01
This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.
Krüsi, Andrea; Chettiar, Jill; Ridgway, Amelia; Abbott, Janice; Strathdee, Steffanie A; Shannon, Kate
2012-06-01
We examined how unique, low-barrier, supportive housing programs for women who are functioning as unsanctioned indoor sex work environments in a Canadian urban setting influence risk negotiation with clients in sex work transactions. We conducted 39 semistructured qualitative interviews and 6 focus groups with women who live in low-barrier, supportive housing for marginalized sex workers with substance use issues. All interviews were transcribed verbatim and thematically analyzed. Women's accounts indicated that unsanctioned indoor sex work environments promoted increased control over negotiating sex work transactions, including the capacity to refuse unwanted services, negotiate condom use, and avoid violent perpetrators. Despite the lack of formal legal and policy support for indoor sex work venues in Canada, the environmental-structural supports afforded by these unsanctioned indoor sex work environments, including surveillance cameras and support from staff or police in removing violent clients, were linked to improved police relationships and facilitated the institution of informal peer-safety mechanisms. This study has drawn attention to the potential role of safer indoor sex work environments as venues for public health and violence prevention interventions and has indicated the critical importance of removing the sociolegal barriers preventing the formal implementation of such programs.
Krüsi, Andrea; Chettiar, Jill; Ridgway, Amelia; Abbott, Janice; Strathdee, Steffanie A.
2012-01-01
Objectives. We examined how unique, low-barrier, supportive housing programs for women who are functioning as unsanctioned indoor sex work environments in a Canadian urban setting influence risk negotiation with clients in sex work transactions. Methods. We conducted 39 semistructured qualitative interviews and 6 focus groups with women who live in low-barrier, supportive housing for marginalized sex workers with substance use issues. All interviews were transcribed verbatim and thematically analyzed. Results. Women’s accounts indicated that unsanctioned indoor sex work environments promoted increased control over negotiating sex work transactions, including the capacity to refuse unwanted services, negotiate condom use, and avoid violent perpetrators. Despite the lack of formal legal and policy support for indoor sex work venues in Canada, the environmental-structural supports afforded by these unsanctioned indoor sex work environments, including surveillance cameras and support from staff or police in removing violent clients, were linked to improved police relationships and facilitated the institution of informal peer-safety mechanisms. Conclusions. This study has drawn attention to the potential role of safer indoor sex work environments as venues for public health and violence prevention interventions and has indicated the critical importance of removing the sociolegal barriers preventing the formal implementation of such programs. PMID:22571708
Brasche, Sabine; Bischof, Wolfgang
2005-01-01
Comprehensive time-activity studies, for use as a basis for estimates of personal exposure, are not readily available in Germany. This analysis of time spent indoors at home is based on data from "Dampness and mould in homes" (2000/ 2001)--a study of about 12,000 persons living in 5530 randomly selected apartments and houses in Germany. The results show the mean times per day people in Germany spend in their homes, classified by gender, age group, building location, city size, region, building type, owner-occupier status, number of people at home, smoking and ventilation habits, moisture emission and ill health factors such as asthma, allergy and number of acute respiratory infections per year. The overall mean time spent at home, 15.7 h per, is in accordance with results from US-American (15.6 h/day) and Canadian (15.8 h/day) human activity surveys carried out in the nineties, as well as being consistent with the German Environmental Survey (1990/92) and a small German study in 1987.
Criegee intermediates in the indoor environment. New insights
Shallcross, D. E.; Taatjes, C. A.; Percival, C. J.
2014-03-25
Criegee intermediates are formed in the ozonolysis of alkenes and play an important role in indoor chemistry, notably as a source of OH radicals. Recent studies have shown that these Criegee intermediates react very quickly with NO 2, SO 2, and carbonyls, and in this study, steady-state calculations are used to inspect the potential impact of these data on indoor chemistry. It is shown that these reactions could accelerate NO 3 formation and SO 2 removal in the indoor environment significantly. In addition, reaction between Criegee intermediates and halogenated carbonyls could provide a significant loss process indoors, where currently onemore » does not exist.« less
Vitality of plants to live in the indoor environment
NASA Astrophysics Data System (ADS)
Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi
2017-09-01
Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live in indoor environment, and can be further studied to treat the indoor air.
NASA Astrophysics Data System (ADS)
Hosseini, Hamid Reza; Yunos, Mohd Yazid Mohd; Ismail, Sumarni; Yaman, Maheran
2017-12-01
This paper analysis the effects of indoor air elements on the dissatisfaction of occupants in education of environments. Tries to find the equation model for increasing the comprehension about these affects and optimizes satisfaction of occupants about indoor environment. Subsequently, increase performance of students, lecturers and staffs. As the method, a satisfaction questionnaire (SQ) and measuring environment elements (MEE) was conducted, 143 respondents at five classrooms, four staff rooms and five lectures rooms were considered. Temperature, air velocity and humidity (TVH) were used as independent variables and dissatisfaction as dependent variable. The hypothesis was tested for significant relationship between variables, and analysis was applied. Results found that indoor air quality presents direct effects on dissatisfaction of occupants and indirect effects on performance and the highest effects fallowed by temperature. These results may help to optimize the quality of efficiency and effectiveness in education environments.
Zota, Ami R.; Fabian, M. Patricia; Chahine, Teresa; Julien, Rhona; Spengler, John D.; Levy, Jonathan I.
2011-01-01
Objectives. The indoor environment has not been fully incorporated into the environmental justice dialogue. To inform strategies to reduce disparities, we developed a framework to identify the individual and place-based drivers of indoor environment quality. Methods. We reviewed empirical evidence of socioeconomic disparities in indoor exposures and key determinants of these exposures for air pollutants, lead, allergens, and semivolatile organic compounds. We also used an indoor air quality model applied to multifamily housing to illustrate how nitrogen dioxide (NO2) and fine particulate matter (PM2.5) vary as a function of factors known to be influenced by socioeconomic status. Results. Indoor concentrations of multiple pollutants are elevated in low-socioeconomic status households. Differences in these exposures are driven by the combined influences of indoor sources, outdoor sources, physical structures, and residential activity patterns. Simulation models confirmed indoor sources’ importance in determining indoor NO2 and PM2.5 exposures and showed the influence of household-specific determinants. Conclusions. Both theoretical models and empirical evidence emphasized that disparities in indoor environmental exposure can be significant. Understanding key determinants of multiple indoor exposures can aid in developing policies to reduce these disparities. PMID:21836112
Exposure to airborne engineered nanoparticles in the indoor environment
NASA Astrophysics Data System (ADS)
Vance, Marina E.; Marr, Linsey C.
2015-04-01
This literature review assesses the current state of knowledge about inhalation exposure to airborne, engineered nanoparticles in the indoor environment. We present principal exposure scenarios in indoor environments, complemented by analysis of the published literature and of an inventory of nanotechnology-enhanced consumer products. Of all products listed in the inventory, 10.8% (194 products) present the potential for aerosolization of nanomaterials and subsequent inhalation exposure during use or misuse. Among those, silver-containing products are the most prevalent (68 products). Roughly 50% of products would release wet aerosols and 50% would potentially release dry aerosols. Approximately 14% are cleaning products that can be broadly used in public indoor environments, where building occupants may be exposed. While a variety of nanomaterial compositions have been investigated in the limited number of published release and exposure studies, we identified a need for studies investigating nanofibers (beyond carbon nanotubes), nanofilms, nanoplatelets, and other emerging nanomaterials such as ceria and their nanocomposites. Finally, we provide recommendations for future research to advance the understanding of exposure to airborne nanomaterials indoors, such as studies into indoor chemistry of nanomaterials, better nanomaterial reporting and labeling in consumer products, and safer design of nanomaterial-containing consumer products.
Syazwan, Aizat Ismail; Hafizan, Juahir; Baharudin, Mohd Rafee; Azman, Ahmad Zaid Fattah; Izwyn, Zulkapri; Zulfadhli, Ismail; Syahidatussyakirah, Katis
2013-01-01
Objectives: The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers. Design: A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia. Methods: A set of modified published questionnaires by the Department of Occupational Safety and Health (DOSH), Malaysia and a previous study (MM040NA questionnaire) pertaining to indoor air symptoms was used in the evaluation process of the indoor air symptoms. Statistical analyses involving logistic regression and linear regression were used to determine the relationship between exposure and indoor air symptoms for use in the development of an indoor risk matrix. Results: The results indicate that some indoor air pollutants (carbon monoxide, formaldehyde, total volatile organic compound, and dust) are related to indoor air symptoms of men and women. Temperature and relative humidity showed a positive association with complaints related to the perceived indoor environmental condition (drafts and inconsistency of temperature). Men predominantly reported general symptoms when stratification of gender involved exposure to formaldehyde. Women reported high levels of complaints related to mucosal and general symptoms from exposure to the dust level indoors. Conclusion: Exposure to pollutants (total volatile organic compounds, carbon monoxide, and formaldehyde) and physical stressors (air temperature and relative humidity) influence reported symptoms of office workers. These parameters should be focused upon and graded as one of the important elements in the grading procedure when qualitatively evaluating the indoor environment. PMID:23526736
Syazwan, Aizat Ismail; Hafizan, Juahir; Baharudin, Mohd Rafee; Azman, Ahmad Zaid Fattah; Izwyn, Zulkapri; Zulfadhli, Ismail; Syahidatussyakirah, Katis
2013-01-01
The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers. A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia. A set of modified published questionnaires by the Department of Occupational Safety and Health (DOSH), Malaysia and a previous study (MM040NA questionnaire) pertaining to indoor air symptoms was used in the evaluation process of the indoor air symptoms. Statistical analyses involving logistic regression and linear regression were used to determine the relationship between exposure and indoor air symptoms for use in the development of an indoor risk matrix. The results indicate that some indoor air pollutants (carbon monoxide, formaldehyde, total volatile organic compound, and dust) are related to indoor air symptoms of men and women. Temperature and relative humidity showed a positive association with complaints related to the perceived indoor environmental condition (drafts and inconsistency of temperature). Men predominantly reported general symptoms when stratification of gender involved exposure to formaldehyde. Women reported high levels of complaints related to mucosal and general symptoms from exposure to the dust level indoors. Exposure to pollutants (total volatile organic compounds, carbon monoxide, and formaldehyde) and physical stressors (air temperature and relative humidity) influence reported symptoms of office workers. These parameters should be focused upon and graded as one of the important elements in the grading procedure when qualitatively evaluating the indoor environment.
Reducing indoor residential exposures to outdoor pollutants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.; Matson, Nance E.
2003-07-01
The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts thatmore » typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.« less
NASA Astrophysics Data System (ADS)
Zainon, Mohamad Rizal; Baharum, Faizal; Seng, Loh Yong
2016-08-01
The indoor environment much more important for people health and comfort than the outdoor environment. This scenario would make the performance of occupants at their work more important than energy costs in the building. So, this task is to upgrade indoor environmental quality conditions for comfort and work performance of occupants in Kompleks Eureka, USM while conserving energy of the building.. Recent studies have shown an important impact of the indoor thermal environment on occupants' work performance. Also studies on occupants medical leave show a very high loss of work time and working performance, which have important economical consequences for companies. The paper will mainly dealing with the indoor environmental qualities, such as thermal comfort level, air quality, lighting, and acoustic quality. The studies before showing that comfortable room temperatures, increased air ventilation above normal recommendation, comfortable acoustic surrounding will increases the work performance of occupants in Kompleks Eureka, USM.
Risk factors of indoor fall injuries in community-dwelling older women: a prospective cohort study.
Hu, Jia; Xia, Qinghua; Jiang, Yu; Zhou, Peng; Li, Yuhua
2015-01-01
The aims of the study were to explore the characteristics and the potential risk factors of indoor fall injuries in community-dwelling older women, and to provide evidence for the future intervention strategy. A prospective cohort of 3043 women aged 60 years old and above from 3 selected counties in Shanghai was followed up on the outcomes of indoor fall injuries for up to 1 year. Demographic and health data were collected during admission; the physical function, balance ability and home-living environment were examined by a structured questionnaire when admitted. The outcome of indoor fall injury was investigated by a visit in month 3, month 6 and month 12 after baseline survey. Univariate analysis and Multiple Logistic Regression Model were used to examine the associations between potential risk factors and outcomes of indoor fall injuries. Two hundred and thirty-one of the 3043 women (7.6%) eventually suffered indoor fall injuries at least once during the 1-year follow-up. The injurious falls of women were significantly associated with age, educational level, marital status, health status, balance ability, physical activity and home-living environment in the univariate analyses. Women who worried about falls and restrained activities for it were more likely to suffer fall injury. Younger women, with less chronic disease, with good balance ability and living in good corridor environment, were less likely to receive fall injury in multiple logistic regression analyses. Multidimensional factors were associated with indoor fall injuries for community-dwelling older women. Proper clinical treatment of chronic disease and improvement of women's balance ability, as well as reducing the risk factor of indoor environment, which will play vital roles in preventing indoor fall injuries, should be prioritized for the intervention strategy. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Preparation and response to weather-related and man-made emergencies is particularly important when it comes to indoor environments, since humans spend most of their time indoors, and rely on indoor spaces for shelter.
Indoor localization using FM radio and DTMB signals
NASA Astrophysics Data System (ADS)
Wu, H.; Wang, Q.; Zhao, Y.; Ma, X.; Yang, M.; Liu, B.; Tang, R.; Xu, X.
2016-07-01
Indoor localization systems based on Wi-Fi signal strength fingerprinting techniques are widely used in office buildings. However, a general problem of these systems pertains to Wi-Fi signal degradation due to the environmental factors. And also, these systems cannot be used in the environments not covered with Wi-Fi signals or the environments with only a single Wi-Fi access point. In this paper, a new indoor location fingerprinting system using both FM radio and Digital Television Terrestrial Multimedia Broadcasting (DTMB) signals is proposed. First, the indoor location fingerprinting using FM radio and DTMB signals is theoretically analyzed to confirm its feasibility. Then, a specially designed combined strength fingerprinting location algorithm is proposed for the location system, which is achieved on the USRP2 platform. Finally, the system is tested in a typical indoor environment. The theoretical analysis and the tests show that the indoor location fingerprinting system using FM radio and DTMB signals has a similar localization accuracy to the Wi-Fi signal strength fingerprinting location system, while it has a wider coverage area, a lower maintenance cost, and more stable signal strength, which makes it a practical indoor positioning method.
Cooperative Agreement Funding for Indoor Air Quality
The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.
Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter
2016-05-01
Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.
Syazwan, AI; Rafee, B Mohd; Juahir, Hafizan; Azman, AZF; Nizar, AM; Izwyn, Z; Syahidatussyakirah, K; Muhaimin, AA; Yunos, MA Syafiq; Anita, AR; Hanafiah, J Muhamad; Shaharuddin, MS; Ibthisham, A Mohd; Hasmadi, I Mohd; Azhar, MN Mohamad; Azizan, HS; Zulfadhli, I; Othman, J; Rozalini, M; Kamarul, FT
2012-01-01
Purpose To analyze and characterize a multidisciplinary, integrated indoor air quality checklist for evaluating the health risk of building occupants in a nonindustrial workplace setting. Design A cross-sectional study based on a participatory occupational health program conducted by the National Institute of Occupational Safety and Health (Malaysia) and Universiti Putra Malaysia. Method A modified version of the indoor environmental checklist published by the Department of Occupational Health and Safety, based on the literature and discussion with occupational health and safety professionals, was used in the evaluation process. Summated scores were given according to the cluster analysis and principal component analysis in the characterization of risk. Environmetric techniques was used to classify the risk of variables in the checklist. Identification of the possible source of item pollutants was also evaluated from a semiquantitative approach. Result Hierarchical agglomerative cluster analysis resulted in the grouping of factorial components into three clusters (high complaint, moderate-high complaint, moderate complaint), which were further analyzed by discriminant analysis. From this, 15 major variables that influence indoor air quality were determined. Principal component analysis of each cluster revealed that the main factors influencing the high complaint group were fungal-related problems, chemical indoor dispersion, detergent, renovation, thermal comfort, and location of fresh air intake. The moderate-high complaint group showed significant high loading on ventilation, air filters, and smoking-related activities. The moderate complaint group showed high loading on dampness, odor, and thermal comfort. Conclusion This semiquantitative assessment, which graded risk from low to high based on the intensity of the problem, shows promising and reliable results. It should be used as an important tool in the preliminary assessment of indoor air quality and as a categorizing method for further IAQ investigations and complaints procedures. PMID:23055779
Syazwan, Ai; Rafee, B Mohd; Juahir, Hafizan; Azman, Azf; Nizar, Am; Izwyn, Z; Syahidatussyakirah, K; Muhaimin, Aa; Yunos, Ma Syafiq; Anita, Ar; Hanafiah, J Muhamad; Shaharuddin, Ms; Ibthisham, A Mohd; Hasmadi, I Mohd; Azhar, Mn Mohamad; Azizan, Hs; Zulfadhli, I; Othman, J; Rozalini, M; Kamarul, Ft
2012-01-01
To analyze and characterize a multidisciplinary, integrated indoor air quality checklist for evaluating the health risk of building occupants in a nonindustrial workplace setting. A cross-sectional study based on a participatory occupational health program conducted by the National Institute of Occupational Safety and Health (Malaysia) and Universiti Putra Malaysia. A modified version of the indoor environmental checklist published by the Department of Occupational Health and Safety, based on the literature and discussion with occupational health and safety professionals, was used in the evaluation process. Summated scores were given according to the cluster analysis and principal component analysis in the characterization of risk. Environmetric techniques was used to classify the risk of variables in the checklist. Identification of the possible source of item pollutants was also evaluated from a semiquantitative approach. Hierarchical agglomerative cluster analysis resulted in the grouping of factorial components into three clusters (high complaint, moderate-high complaint, moderate complaint), which were further analyzed by discriminant analysis. From this, 15 major variables that influence indoor air quality were determined. Principal component analysis of each cluster revealed that the main factors influencing the high complaint group were fungal-related problems, chemical indoor dispersion, detergent, renovation, thermal comfort, and location of fresh air intake. The moderate-high complaint group showed significant high loading on ventilation, air filters, and smoking-related activities. The moderate complaint group showed high loading on dampness, odor, and thermal comfort. This semiquantitative assessment, which graded risk from low to high based on the intensity of the problem, shows promising and reliable results. It should be used as an important tool in the preliminary assessment of indoor air quality and as a categorizing method for further IAQ investigations and complaints procedures.
Parent's Guide to School Indoor Air Quality. Revised
ERIC Educational Resources Information Center
Healthy Schools Network, Inc., 2012
2012-01-01
Air pollution is air pollution, indoors or out. Good indoor air quality (IAQ) contributes to a favorable learning environment for students, protects health, and supports the productivity of school personnel. In schools in poor repair, leaky roofs and crumbling walls have caused additional indoor air quality problems, including contamination with…
Challenges in Flying Quadrotor Unmanned Aerial Vehicle for 3d Indoor Reconstruction
NASA Astrophysics Data System (ADS)
Yan, J.; Grasso, N.; Zlatanova, S.; Braggaar, R. C.; Marx, D. B.
2017-09-01
Three-dimensional modelling plays a vital role in indoor 3D tracking, navigation, guidance and emergency evacuation. Reconstruction of indoor 3D models is still problematic, in part, because indoor spaces provide challenges less-documented than their outdoor counterparts. Challenges include obstacles curtailing image and point cloud capture, restricted accessibility and a wide array of indoor objects, each with unique semantics. Reconstruction of indoor environments can be achieved through a photogrammetric approach, e.g. by using image frames, aligned using recurring corresponding image points (CIP) to build coloured point clouds. Our experiments were conducted by flying a QUAV in three indoor environments and later reconstructing 3D models which were analysed under different conditions. Point clouds and meshes were created using Agisoft PhotoScan Professional. We concentrated on flight paths from two vantage points: 1) safety and security while flying indoors and 2) data collection needed for reconstruction of 3D models. We surmised that the main challenges in providing safe flight paths are related to the physical configuration of indoor environments, privacy issues, the presence of people and light conditions. We observed that the quality of recorded video used for 3D reconstruction has a high dependency on surface materials, wall textures and object types being reconstructed. Our results show that 3D indoor reconstruction predicated on video capture using a QUAV is indeed feasible, but close attention should be paid to flight paths and conditions ultimately influencing the quality of 3D models. Moreover, it should be decided in advance which objects need to be reconstructed, e.g. bare rooms or detailed furniture.
Hegarty, B; Dannemiller, K C; Peccia, J
2018-03-03
Dampness and visible mold growth in homes are associated with negative human health outcomes, but causal relationships between fungal exposure and health are not well established. The purpose of this study was to determine whether dampness in buildings impacts fungal community gene expression and how, in turn, gene expression may modulate human health impacts. A metatranscriptomic study was performed on house dust fungal communities to investigate the expression of genes and metabolic processes in chamber experiments at water activity levels of 0.5, 0.85, and 1.0. Fungi at water activities as low as 0.5 were metabolically active, focusing their transcriptional resources on primary processes essential for cell maintenance. Metabolic complexity increased with water activity where communities at 1.0 displayed more diverse secondary metabolic processes. Greater gene expression at increasing water activity has important implications for human health: Fungal communities at 1.0 a w upregulated a greater number of allergen-, mycotoxin-, and pathogenicity-encoding genes versus communities at 0.85 and 0.5 a w . In damp buildings, fungi may display increases in secondary metabolic processes with the potential for greater per-cell production of allergens, toxins, and pathogenicity. Assessments in wet versus dry buildings that do not account for this elevated health impact may not accurately reflect exposure. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Test and analysis of indoor environment of dormitories of universities in autumn
NASA Astrophysics Data System (ADS)
Chen, Shijia
2017-03-01
In this paper, the indoor thermal and humid environment, luminous environment and acoustic environment of college dormitories in Baoding are tested and conducted a questionnaire survey. From the test, the subjective feelings and the objective evaluation parameters of the students in the dormitory were obtained. At last, the differences of thermal comfort, luminous environment and acoustic environment caused by students' different living habits and adaptability were analyzed.
Dieng, Hamady; Saifur, Rahman G M; Hassan, Ahmad Abu; Salmah, M R Che; Boots, Michael; Satho, Tomomitsu; Jaal, Zairi; AbuBakar, Sazaly
2010-07-27
The mosquito Ae. albopictus is usually adapted to the peri-domestic environment and typically breeds outdoors. However, we observed its larvae in most containers within homes in northern peninsular Malaysia. To anticipate the epidemiological implications of this indoor-breeding, we assessed some fitness traits affecting vectorial capacity during colonization process. Specifically, we examined whether Ae. albopictus exhibits increased survival, gonotrophic activity and fecundity due to the potential increase in blood feeding opportunities. In a series of experiments involving outdoors and indoors breeding populations, we found that Ae. albopictus lives longer in the indoor environment. We also observed increased nighttime biting activity and lifetime fecundity in indoor/domestic adapted females, although they were similar to recently colonized females in body size. Taken together these data suggest that accommodation of Ae. albopictus to indoor/domestic environment may increase its lifespan, blood feeding success, nuisance and thus vectorial capacity (both in terms of increased vector-host contacts and vector population density). These changes in the breeding behavior of Ae. albopictus, a potential vector of several human pathogens including dengue viruses, require special attention.
CFD simulation research on residential indoor air quality.
Yang, Li; Ye, Miao; He, Bao-Jie
2014-02-15
Nowadays people are excessively depending on air conditioning to create a comfortable indoor environment, but it could cause some health problems in a long run. In this paper, wind velocity field, temperature field and air age field in a bedroom with wall-hanging air conditioning running in summer are analyzed by CFD numerical simulation technology. The results show that wall-hanging air conditioning system can undertake indoor heat load and conduct good indoor thermal comfort. In terms of wind velocity, air speed in activity area where people sit and stand is moderate, most of which cannot feel wind flow and meet the summer indoor wind comfort requirement. However, for air quality, there are local areas without ventilation and toxic gases not discharged in time. Therefore it is necessary to take effective measures to improve air quality. Compared with the traditional measurement method, CFD software has many advantages in simulating indoor environment, so it is hopeful for humans to create a more comfortable, healthy living environment by CFD in the future. Copyright © 2013 Elsevier B.V. All rights reserved.
Analysis of Indoor Environment in Classroom Based on Hygienic Requirements
NASA Astrophysics Data System (ADS)
Javorček, Miroslav; Sternová, Zuzana
2016-06-01
The article contains the analysis of experimental ventilation measurement in selected classrooms of the Elementary School Štrba. Mathematical model of selected classroom was prepared according to in-situ measurements and air exchange was calculated. Interior air temperature and quality influences the students ´ comfort. Evaluated data were compared to requirements of standard (STN EN 15251,2008) applicable to classroom indoor environment during lectures, highlighting the difference between required ambiance quality and actually measured values. CO2 concentration refers to one of the parameters indicating indoor environment quality.
ERIC Educational Resources Information Center
Milshtein, Amy
2000-01-01
Discusses the special indoor air quality issues confronting school gyms, locker rooms, and pools; and explores ways to keep the indoor environment healthy. Included are discussions of mold and fungus control and air issues stemming from indoor pools. (GR)
Liu, X; Zhai, Z
2008-02-01
Indoor pollutions jeopardize human health and welfare and may even cause serious morbidity and mortality under extreme conditions. To effectively control and improve indoor environment quality requires immediate interpretation of pollutant sensor readings and accurate identification of indoor pollution history and source characteristics (e.g. source location and release time). This procedure is complicated by non-uniform and dynamic contaminant indoor dispersion behaviors as well as diverse sensor network distributions. This paper introduces a probability concept based inverse modeling method that is able to identify the source location for an instantaneous point source placed in an enclosed environment with known source release time. The study presents the mathematical models that address three different sensing scenarios: sensors without concentration readings, sensors with spatial concentration readings, and sensors with temporal concentration readings. The paper demonstrates the inverse modeling method and algorithm with two case studies: air pollution in an office space and in an aircraft cabin. The predictions were successfully verified against the forward simulation settings, indicating good capability of the method in finding indoor pollutant sources. The research lays a solid ground for further study of the method for more complicated indoor contamination problems. The method developed can help track indoor contaminant source location with limited sensor outputs. This will ensure an effective and prompt execution of building control strategies and thus achieve a healthy and safe indoor environment. The method can also assist the design of optimal sensor networks.
Johanning, Eckardt; Auger, Pierre; Morey, Philip R; Yang, Chin S; Olmsted, Ed
2014-03-01
Health problems and illnesses encountered by unprotected workers, first-responders, home-owners, and volunteers in recovery and restoration of moldy indoor environments after hurricanes, typhoons, tropical storms, and flooding damage are a growing concern for healthcare providers and disaster medicine throughout the world. Damp building materials, particularly cellulose-containing substrates, are prone to fungal (mold) and bacterial infestation. During remediation and demolition work, the airborne concentrations of such microbes and their by-products can rise significantly and result in an exposure risk. Symptoms reported by unprotected workers and volunteers may relate to reactions of the airways, skin, mucous membranes, or internal organs. Dampness-related fungi are primarily associated with allergies, respiratory symptoms or diseases such as dermatitis, rhinosinusitis, bronchitis, and asthma, as well as changes of the immunological system. Also, cognitive, endocrine, or rheumatological changes have been reported. Based on the consensus among experts at a recent scientific conference and a literature review, it is generally recommended to avoid and minimize unnecessary fungal exposure and use appropriate personal protective equipment (PPE) in disaster response and recovery work. Mycologists recommend addressing any moisture or water intrusion rapidly, since significant mold growth can occur within 48 h. Systematic source removal, cleaning with "soap and water," and "bulk removal" followed by high-efficiency particulate air vacuuming is recommended in most cases; use of "biocides" should be avoided in occupied areas. Public health agencies recommend use of adequate respiratory, skin, and eye protection. Workers can be protected against these diseases by use of dust control measures and appropriate personal protective equipment. At a minimum, a facial dust mask such as the National Institute for Occupational Safety and Health (NIOSH)-approved N95 respirator should be used for mold remediation jobs. For any large-scale projects, trained remediation workers who have medical clearance and use proper personal protection (PPE) should be employed.
Kaufhold, T; Fiedler, K; Jung, G; Lindner, M; Gassel, R P
1997-04-01
Reasons for indoor-moisture beyond the normal level can be caused by penetrating dampness, condensation-water, and apartment misuse. A fall in the air temperature below the dew point in connection with moulding inside buildings becomes evident mostly at places like badly insulated outer-walls or room-corners. In a number of houses built between 1980 and 1983 in the so called "Plattenbauweise" (prefabricated slabs), exclusively the inner-walls were covered in mould around cracks in the walls. Examinations showed connections between the apartment and the outer-corridor with a slight exchange of air through the cracks. Warm, wet air escaped from the apartment into the outer-corridor, and cold air entered the apartment from the outer-corridor. This temporary fall below the dewpoint caused by suitable variation of temperature probably resulted in the building materials and wallpapers becoming damp, as well as the growth of mould.
1989-11-01
environments that the inlet ring encounters and verifying the failure mechanisms through analysis and laboratory test. Due to the inlet ring’s proximity to the...these environments and duty cycles were further explored through finite element analysis and laboratory testing of the baseline structure. An MSC...Layer Damping Applications J. P. Coulter, T. G. Duclos and D. N. Acker CAA Analysis of a Modified Passive Hydraulic Damper with Variable Damping
Monitoring Indoor Air Quality for Enhanced Occupational Health.
Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque
2017-02-01
Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".
Liu, Wen; Fu, Xiao; Deng, Zhongliang
2016-12-02
Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means.
Liu, Wen; Fu, Xiao; Deng, Zhongliang
2016-01-01
Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means. PMID:27918454
Report #09-P-0053, December 9, 2008. Vulnerability testing of EPA’s Radiation and Indoor Environments National Laboratory (R&IEN) network identified Internet Protocol addresses with medium-risk vulnerabilities.
The Airborne Metagenome in an Indoor Urban Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tringe, Susannah; Zhang, Tao; Liu, Xuguo
2008-02-12
The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are notmore » random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.« less
The Airborne Metagenome in an Indoor Urban Environment
Liu, Xuguo; Yu, Yiting; Lee, Wah Heng; Yap, Jennifer; Yao, Fei; Suan, Sim Tiow; Ing, Seah Keng; Haynes, Matthew; Rohwer, Forest; Wei, Chia Lin; Tan, Patrick; Bristow, James; Rubin, Edward M.; Ruan, Yijun
2008-01-01
The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens. PMID:18382653
[Environmental quality: wellfare, confort and health].
Vargas Marcos, Francisco; Gallego Pulgarín, Isabel
2005-01-01
Different ways of interpreting environmental conditions have led to the development of concepts such as the sick building, indoor air quality or indoor environment quality, for understanding the complexity of the pollutants in enclosed environments and the implications thereof on the health. The "Indoor Environment Quality" proposal is an advancement, operative and conceptual, surpassing amply prior ones, given that it orients the actions toward healthy environments without limiting the idea of pollution to the air alone. The aim is identifying the competence to preventing hazards related to exposure to pollutants within the confines of indoor environments and know the legislative framework useful for taking the actions. Optimum conditions within indoor environments must redound in health, well-being and comfort with regard to both working life as well as the environments in which everyday activities outside of work, extracurricular, leisure-time and entertainment activities are carried out. Today's society is demanding safe, clean, well-climatized places, for this is necessary to integrate the inhabitant's perceptions and demands and achieve an optimum balance among social standards, energy use and sustainable development. Legislation is being further expanded upon in the direction of occupational health and safety and the regulation of chemical substances. Environmental Health carries out prevention and control tasks, takes part in the enforcement of international pollution and waste reduction agreements and promotes measures for carrying out the European Environment and Health Strategy. It is considered useful the elaboration of protocols for the evaluation and administration gives the risks associated to the interior pollutants.
Feasibility study on mental healthcare using indoor plants for office workers
NASA Astrophysics Data System (ADS)
Kubota, Tsuyoshi; Matsumoto, Hiroshi; Genjo, Kaori; Nakano, Takaoki
2017-10-01
In recent years, it has become a problem that office workers' stresses affect their intellectual productivity. As one of strategies mitigating the stress while working, many studies on the effect of indoor plants introduced into the office have been conducted. The psychological and physiological effects of indoor plants have been expected to mitigate the office workers' stresses. Also, the effects of green amenities such as improvement of productivity, control of the indoor thermal environment, relaxation and recovery of visual fatigue, and improvement of air quality have been expected. In this study, a field investigation on the green amenity effects of indoor plants on office workers' psychological and physiological responses in an actual office was conducted and discussed. This paper describes the measurement results of the physical environment and workers' psychological and physiological responses under the condition with shelves installed with indoor plants in an office room. It was suggested that indoor plants such as mint, basil and begonia, and a combination of red and green plants were effective for mitigating worker's stresses.
Source apportionment of indoor air pollution
NASA Astrophysics Data System (ADS)
Sexton, Ken; Hayward, Steven B.
An understanding of the relative contributions from important pollutant sources to human exposures is necessary for the design and implementation of effective control strategies. In the past, societal efforts to control air pollution have focused almost exclusively on the outdoor (ambient) environment. As a result, substantial amounts of time and money have been spent to limit airborne discharges from mobile and stationary sources. Yet it is now recognized that exposures to elevated pollutant concentrations often occur as a result of indoor, rather than outdoor, emissions. While the major indoor sources have been identified, their relative impacts on indoor air quality have not been well defined. Application of existing source apportionment models to nonindustrial indoor environments is only just beginning. It is possible that these models might be used to distinguish between indoor and outdoor emissions, as well as to distinguish among indoor sources themselves. However, before the feasibility and suitability of source-apportionment methods for indoor applications can be assessed adequately, it is necessary to take account of model assumptions and associated data requirements. This paper examines the issue of indoor source apportionment and reviews the need for emission characterization studies to support such source-apportionment efforts.
Parents and Students and Healthy Indoor School Environments
School-aged children spend a great deal of time inside school buildings. Parents can play an important role in creating healthy indoor school environments. Parents and students alike can make a powerful case for protecting health in schools.
Chua, M L; Setyawati, M I; Li, H; Fang, C H Y; Gurusamy, S; Teoh, F T L; Leong, D T; George, S
2017-05-01
We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Oxidative stress-dependent cytotoxicity responses were assessed using quantitative reverse transcriptase polymerase chain reaction (RT-PCR) and high content screening (HCS), and disruption of monolayer cell integrity was assessed using fluorescence microscopy and transwell assay. Scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDX) analysis showed differences in the morphology and elemental composition of PM of different sizes and origins. While the total mass of PM collected from indoor environment was lower in comparison with those collected from the corridor, the endotoxin content was substantially higher in indoor PM (e.g., ninefold higher endotoxin level in indoor PM 8.1-20 ). The ability to induce oxidative stress-mediated cytotoxicity and leakiness in cell monolayer were higher for indoor PM compared to those collected from the corridor. In conclusion, this comparative analysis suggested that indoor PM is relatively more hazardous to the endothelial system possibly because of higher endotoxin content. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Indoor environment program. 1994 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daisey, J.M.
1995-04-01
Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, andmore » energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.« less
Takaro, Tim K; Scott, James A; Allen, Ryan W; Anand, Sonia S; Becker, Allan B; Befus, A Dean; Brauer, Michael; Duncan, Joanne; Lefebvre, Diana L; Lou, Wendy; Mandhane, Piush J; McLean, Kathleen E; Miller, Gregory; Sbihi, Hind; Shu, Huan; Subbarao, Padmaja; Turvey, Stuart E; Wheeler, Amanda J; Zeng, Leilei; Sears, Malcolm R; Brook, Jeffrey R
2015-01-01
The Canadian Healthy Infant Longitudinal Development birth cohort was designed to elucidate interactions between environment and genetics underlying development of asthma and allergy. Over 3600 pregnant mothers were recruited from the general population in four provinces with diverse environments. The child is followed to age 5 years, with prospective characterization of diverse exposures during this critical period. Key exposure domains include indoor and outdoor air pollutants, inhalation, ingestion and dermal uptake of chemicals, mold, dampness, biological allergens, pets and pests, housing structure, and living behavior, together with infections, nutrition, psychosocial environment, and medications. Assessments of early life exposures are focused on those linked to inflammatory responses driven by the acquired and innate immune systems. Mothers complete extensive environmental questionnaires including time-activity behavior at recruitment and when the child is 3, 6, 12, 24, 30, 36, 48, and 60 months old. House dust collected during a thorough home assessment at 3–4 months, and biological specimens obtained for multiple exposure-related measurements, are archived for analyses. Geo-locations of homes and daycares and land-use regression for estimating traffic-related air pollution complement time-activity-behavior data to provide comprehensive individual exposure profiles. Several analytical frameworks are proposed to address the many interacting exposure variables and potential issues of co-linearity in this complex data set. PMID:25805254
Architectural design influences the diversity and structure of the built environment microbiome
Kembel, Steven W; Jones, Evan; Kline, Jeff; Northcutt, Dale; Stenson, Jason; Womack, Ann M; Bohannan, Brendan JM; Brown, G Z; Green, Jessica L
2012-01-01
Buildings are complex ecosystems that house trillions of microorganisms interacting with each other, with humans and with their environment. Understanding the ecological and evolutionary processes that determine the diversity and composition of the built environment microbiome—the community of microorganisms that live indoors—is important for understanding the relationship between building design, biodiversity and human health. In this study, we used high-throughput sequencing of the bacterial 16S rRNA gene to quantify relationships between building attributes and airborne bacterial communities at a health-care facility. We quantified airborne bacterial community structure and environmental conditions in patient rooms exposed to mechanical or window ventilation and in outdoor air. The phylogenetic diversity of airborne bacterial communities was lower indoors than outdoors, and mechanically ventilated rooms contained less diverse microbial communities than did window-ventilated rooms. Bacterial communities in indoor environments contained many taxa that are absent or rare outdoors, including taxa closely related to potential human pathogens. Building attributes, specifically the source of ventilation air, airflow rates, relative humidity and temperature, were correlated with the diversity and composition of indoor bacterial communities. The relative abundance of bacteria closely related to human pathogens was higher indoors than outdoors, and higher in rooms with lower airflow rates and lower relative humidity. The observed relationship between building design and airborne bacterial diversity suggests that we can manage indoor environments, altering through building design and operation the community of microbial species that potentially colonize the human microbiome during our time indoors. PMID:22278670
Toyinbo, Oluyemi; Matilainen, Markus; Turunen, Mari; Putus, Tuula; Shaughnessy, Richard; Haverinen-Shaughnessy, Ulla
2016-03-30
The aim of this paper was to examine associations between school building characteristics, indoor environmental quality (IEQ), and health responses using questionnaire data from both school principals and students. From 334 randomly sampled schools, 4248 sixth grade students from 297 schools participated in a questionnaire. From these schools, 134 principals returned questionnaires concerning 51 IEQ related questions of their school. Generalized linear mixed models (GLMM) were used to study the associations between IEQ indicators and existence of self-reported upper respiratory symptoms, while hierarchical Zero Inflated Poisson (ZIP)-models were used to model the number of symptoms. Significant associations were established between existence of upper respiratory symptoms and unsatisfactory classroom temperature during the heating season (ORs 1.45 for too hot and cold, and 1.27 for too cold as compared to satisfactory temperature) and dampness or moisture damage during the year 2006-2007 (OR: 1.80 as compared to no moisture damage), respectively. The number of upper respiratory symptoms was significantly associated with inadequate ventilation and dampness or moisture damage. A higher number of missed school days due to respiratory infections were reported in schools with inadequate ventilation (RR: 1.16). The school level IEQ indicator variables described in this paper could explain a relatively large part of the school level variation observed in the self-reported upper respiratory symptoms and missed school days due to respiratory infections among students.
Toyinbo, Oluyemi; Matilainen, Markus; Turunen, Mari; Putus, Tuula; Shaughnessy, Richard; Haverinen-Shaughnessy, Ulla
2016-01-01
Background: The aim of this paper was to examine associations between school building characteristics, indoor environmental quality (IEQ), and health responses using questionnaire data from both school principals and students. Methods: From 334 randomly sampled schools, 4248 sixth grade students from 297 schools participated in a questionnaire. From these schools, 134 principals returned questionnaires concerning 51 IEQ related questions of their school. Generalized linear mixed models (GLMM) were used to study the associations between IEQ indicators and existence of self-reported upper respiratory symptoms, while hierarchical Zero Inflated Poisson (ZIP)—models were used to model the number of symptoms. Results: Significant associations were established between existence of upper respiratory symptoms and unsatisfactory classroom temperature during the heating season (ORs 1.45 for too hot and cold, and 1.27 for too cold as compared to satisfactory temperature) and dampness or moisture damage during the year 2006–2007 (OR: 1.80 as compared to no moisture damage), respectively. The number of upper respiratory symptoms was significantly associated with inadequate ventilation and dampness or moisture damage. A higher number of missed school days due to respiratory infections were reported in schools with inadequate ventilation (RR: 1.16). Conclusions: The school level IEQ indicator variables described in this paper could explain a relatively large part of the school level variation observed in the self-reported upper respiratory symptoms and missed school days due to respiratory infections among students. PMID:27043595
Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud
2016-03-01
Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Using Openstreetmap Data to Generate Building Models with Their Inner Structures for 3d Maps
NASA Astrophysics Data System (ADS)
Wang, Z.; Zipf, A.
2017-09-01
With the development of Web 2.0, more and more data related to indoor environments has been collected within the volunteered geographic information (VGI) framework, which creates a need for construction of indoor environments from VGI. In this study, we focus on generating 3D building models from OpenStreetMap (OSM) data, and provide an approach to support construction and visualization of indoor environments on 3D maps. In this paper, we present an algorithm which can extract building information from OSM data, and can construct building structures as well as inner building components (e.g., doors, rooms, and windows). A web application is built to support the processing and visualization of the building models on a 3D map. We test our approach with an indoor dataset collected from the field. The results show the feasibility of our approach and its potentials to provide support for a wide range of applications, such as indoor and outdoor navigation, urban planning, and incident management.
Application of zonal model on indoor air sensor network design
NASA Astrophysics Data System (ADS)
Chen, Y. Lisa; Wen, Jin
2007-04-01
Growing concerns over the safety of the indoor environment have made the use of sensors ubiquitous. Sensors that detect chemical and biological warfare agents can offer early warning of dangerous contaminants. However, current sensor system design is more informed by intuition and experience rather by systematic design. To develop a sensor system design methodology, a proper indoor airflow modeling approach is needed. Various indoor airflow modeling techniques, from complicated computational fluid dynamics approaches to simplified multi-zone approaches, exist in the literature. In this study, the effects of two airflow modeling techniques, multi-zone modeling technique and zonal modeling technique, on indoor air protection sensor system design are discussed. Common building attack scenarios, using a typical CBW agent, are simulated. Both multi-zone and zonal models are used to predict airflows and contaminant dispersion. Genetic Algorithm is then applied to optimize the sensor location and quantity. Differences in the sensor system design resulting from the two airflow models are discussed for a typical office environment and a large hall environment.
Residential risk factors for childhood pneumonia: A cross-sectional study in eight cities of China.
Zhuge, Yang; Qian, Hua; Zheng, Xiaohong; Huang, Chen; Zhang, Yinping; Zhang, Min; Li, Baizhan; Zhao, Zhuohui; Deng, Qihong; Yang, Xu; Sun, Yuexia; Wang, Tingting; Zhang, Xin; Sundell, Jan
2018-04-11
Children's pneumonia is a heavy health burden. Few studies have been carried out on residential risk factors for pneumonia in children. Potential risks associated with dwelling characteristics are still unknown. A cross-sectional study was conducted among children in 8 cities in China during 2010-2011 and 41,176 valid data on children aged 3-8 years old were used in this analysis. To obtain the lifetime-ever incidence of pneumonia in children and identify associations between pneumonia and residential risk factors, chi-square analysis and logistic regression methods were employed. Adjusted odds ratios were used as measures of effect with a 95% confidence interval. Confounding variables in the regression model include children's gender, birthweight, breastfeeding duration, parental smoking and family history of atopy. The average lifetime-ever incidence of childhood pneumonia was 32.3%. Urban children (33.6%) had more pneumonia than suburban (29.9%) and rural children (24.9%). More residential risk factors were found in urban-dwellings. Boys, low birthweight (<2500 g), breastfeeding duration <6 months, family allergic history, and exposure to parental smoking were found to be associated with higher pneumonia lifetime-ever incidences. Various indicators of dampness, including visible mold spots, damp stains, water damage, water condensation, damp clothing or bedding and mold odor, were also positively associated with pneumonia. Pneumonia incidence increased as the number of dampness indicators increased. Both natural gas and solid cooking fuels were positively associated with pneumonia compared with electricity. Compared with cement, construction materials including synthetic fiber, laminated wood, real wood, paint, emulsion paint and wall paper were positively associated with pneumonia. Daily living habits such as putting bedding to sunshine frequently and cleaning the child's bedroom every day could be effective preventive strategies. A dose-response relationship between the number of residential risk factors and pneumonia was observed when the risk factors number ranged from 7 to 11. Residences with more risk factors had higher lifetime-ever pneumonia odds ratios. Indoor environmental factors including dampness, use of solid fuels or natural gas for cooking and use of new construction materials are risk factors for childhood pneumonia. This study gives evidence for the importance of home environment exposures in the occurrence of childhood pneumonia. Actions against the residential risk factors described in this study may help to prevent pneumonia in children. Copyright © 2018 Elsevier Ltd. All rights reserved.
Microbiological quality of indoor air in university libraries.
Hayleeyesus, Samuel Fekadu; Manaye, Abayneh Melaku
2014-05-01
To evaluate the concentration of bacteria and fungi in the indoor environment of Jimma University libraries, so as to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of eight libraries of Jimma University was determined. The settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Isolates were identified according to standard methods. The concentrations of bacteria and fungi aerosols in the indoor environment of the university libraries ranged between 367-2595 CFU/m(3). According to the sanitary standards classification of European Commission, almost all the libraries indoor air of Jimma University was heavily contaminated with bacteria and fungi. In spite of their major source difference, the average fungi density found in the indoor air of libraries did appear to follow the same trend with bacterial density (P=0.001). The bacteria isolates included Micrococcus sp., Staphylococcus aureus, Streptococcus pyogenes, Bacillus sp. and Neisseria sp. while Cladosporium sp., Alternaria sp., Penicillium sp. and Aspergillus sp. were the most isolated fungi. The indoor air of all libraries were in the range above highly contaminated according to European Commission classification and the most isolates are considered as potential candidates involved in the establishment of sick building syndromes and often associated with clinical manifestations like allergy, rhinitis, asthma and conjunctivitis. Thus, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment of libraries to safeguard the health of users and workers.
Image-Based Localization for Indoor Environment Using Mobile Phone
NASA Astrophysics Data System (ADS)
Huang, Y.; Wang, H.; Zhan, K.; Zhao, J.; Gui, P.; Feng, T.
2015-05-01
Real-time indoor localization based on supporting infrastructures like wireless devices and QR codes are usually costly and labor intensive to implement. In this study, we explored a cheap alternative approach based on images for indoor localization. A user can localize him/herself by just shooting a photo of the surrounding indoor environment using the mobile phone. No any other equipment is required. This is achieved by employing image-matching and searching techniques with a dataset of pre-captured indoor images. In the beginning, a database of structured images of the indoor environment is constructed by using image matching and the bundle adjustment algorithm. Then each image's relative pose (its position and orientation) is estimated and the semantic locations of images are tagged. A user's location can then be determined by comparing a photo taken by the mobile phone to the database. This is done by combining quick image searching, matching and the relative orientation. This study also try to explore image acquisition plans and the processing capacity of off-the-shell mobile phones. During the whole pipeline, a collection of indoor images with both rich and poor textures are examined. Several feature detectors are used and compared. Pre-processing of complex indoor photo is also implemented on the mobile phone. The preliminary experimental results prove the feasibility of this method. In the future, we are trying to raise the efficiency of matching between indoor images and explore the fast 4G wireless communication to ensure the speed and accuracy of the localization based on a client-server framework.
RESEARCH & DEVELOPMENT OF PREVENTION AND CONTROL MEASURES FOR MOLD CONTAMINATION
The U.S. Environmental Protection Agency, Air Pollution Prevention and Control Division, Indoor Environment Management Branch has, since 1995, conducted research into controlling biological contamination in the indoor environment. In this paper four areas of research are discusse...
TESTING ANTIMICROBIAL EFFICACY ON POROUS MATERIALS
The efficacy of antimicrobial treatments to eliminate or control biological growth in the indoor environment can easily be tested on nonporous surfaces. However, the testing of antimicrobial efficacy on porous surfaces, such as those found in the indoor environment [i.e., gypsum ...
Airborne viable fungi in school environments in different climatic regions - A review
NASA Astrophysics Data System (ADS)
Salonen, Heidi; Duchaine, Caroline; Mazaheri, Mandana; Clifford, Sam; Lappalainen, Sanna; Reijula, Kari; Morawska, Lidia
2015-03-01
Elevated levels of fungi in indoor environments have been linked with mould/moisture damage in building structures. However, there is a lack of information about "normal" concentrations and flora as well as guidelines of viable fungi in the school environment in different climatic conditions. We have reviewed existing guidelines for indoor fungi and the current knowledge of the concentrations and flora of viable fungi in different climatic areas, the impact of the local factors on concentrations and flora of viable fungi in school environments. Meta-regression was performed to estimate the average behaviour for each analysis of interest, showing wide variation in the mean concentrations in outdoor and indoor school environments (range: 101-103 cfu/m3). These concentrations were significantly higher for both outdoors and indoors in the moderate than in the continental climatic area, showing that the climatic condition was a determinant for the concentrations of airborne viable fungi. The most common fungal species both in the moderate and continental area were Cladosporium spp. and Penicillium spp. The suggested few quantitative guidelines for indoor air viable fungi for school buildings are much lower than for residential areas. This review provides a synthesis, which can be used to guide the interpretation of the fungi measurements results and help to find indications of mould/moisture in school building structures.
Bi, Xiaolong; Yuan, Shoujun; Pan, Xiaojun; Winstead, Cherese; Wang, Qiquan
2015-01-01
This study aimed to compare and assess phthalate contamination in various indoor environments. In this study, 44 floor dust samples from different indoor environments in Delaware, USA were collected and analyzed for 14 phthalates using gas chromatography-mass spectrometry. Phthalates were detected in all dust samples with the total concentration ranging from 84 to 7117 mg kg(-1). DEHP (di-2-ethylhexyl phthalate), BzBP (benzylbutyl phthalate), DBP (dibutyl phthalate), and DiBP (di-isobutyl phthalate) were both the most frequently and abundantly detected phthalates. The average concentration of total phthalates in dust from offices, student dorms, gyms, stores, and daycare centers was found to be significantly or insignificantly (P = 0.05) higher than that in dust from houses and apartments. Plastic flooring materials and the application of floor care chemical products were positively associated with total phthalate concentration in floor dust. Toxicological risk assessment indicated that an investigated daycare center in this study was the only indoor environment that may cause the intake amount of DEHP of infants, toddlers, and children via dust ingestion to exceed the reference dose established by the U.S. Environmental Protection Agency (USEPA). Regular monitoring on phthalate contamination in sensitive indoor environments is recommended.
Measurement of damping of graphite epoxy composite materials and structural joints
NASA Technical Reports Server (NTRS)
Crocker, Malcolm J.; Rao, Mohan D.; Raju, P. K.; Yan, Xinche
1989-01-01
The damping capacity of graphite epoxy materials and structural joints was evaluated. The damping ratio of different composite specimens and bonded joints were systematically evaluated under normal atmospheric conditions and in a vacuum environment. Free and forced vibration test methods were employed for measuring the damping ratios. The effect of edge support conditions on the damping value of a composite tube specimen was studied by using a series of experiments performed on the specimen with different edge supports. It was found that simulating a free-free boundary conditions by having no constraints at the ends gives the lowest value of the material damping of the composite. The accuracy of the estimation of the damping ratio value was improved by using a curve-fitting technique on the response data obtained through measurement. The effect of outgassing (moisture desorption) on the damping capacity was determined by measuring the damping ratio of the tube specimen in a vacuum environment before and after outgassing had occurred. The effects of high and low temperatures on the damping was also investigated by using a series of experiments on tube and beam specimens. An analytical model to study the vibrations of a bonded lap joint system was formulated. Numerical results were generated for different overlap ratios of the system. These were compared with experimental results. In order to determine the influence of bonded joints on the material damping capacity, experiments were conducted on bonded lap-jointed and double-butt-jointed specimens. These experimental results were compared with simple beam specimens with no joints.
Current Indoor Air Quality in Japan.
Jinno, Hideto
2016-01-01
People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.
Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš
2013-01-01
SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520
Peltola, Joanna S. P.; Andersson, Maria A.; Kämpfer, Peter; Auling, Georg; Kroppenstedt, Reiner M.; Busse, Hans-Jürgen; Salkinoja-Salonen, Mirja S.; Rainey, Frederick A.
2001-01-01
Nocardiopsis strains were isolated from water-damaged indoor environments. Two strains (N. alba subsp. alba 704a and a strain representing a novel species, ES10.1) as well as strains of N. prasina, N. lucentensis, and N. tropica produced methanol-soluble toxins that paralyzed the motility of boar spermatozoa at <30 μg of crude extract (dry weight) ml−1. N. prasina, N. lucentensis, N. tropica, and strain ES10.1 caused cessation of motility by dissipating the mitochondrial membrane potential, Δψ, of the boar spermatozoa. Indoor strain 704a produced a substance that destroyed cell membrane barrier function and depleted the sperm cells of ATP. Indoor strain 64/93 was antagonistic towards Corynebacterium renale. Two indoor Nocardiopsis strains were xerotolerant, and all five utilized a wide range of substrates. This combined with the production of toxic substances suggests good survival and potential hazard to human health in water-damaged indoor environments. Two new species, Nocardiopsis exhalans sp. nov. (ES10.1T) and Nocardiopsis umidischolae sp. nov. (66/93T), are proposed based on morphology, chemotaxonomic and physiological characters, phylogenetic analysis, and DNA-DNA reassociations. PMID:11526036
Dieng, Hamady; Saifur, Rahman G. M.; Hassan, Ahmad Abu; Salmah, M. R. Che; Boots, Michael; Satho, Tomomitsu; Jaal, Zairi; AbuBakar, Sazaly
2010-01-01
Background The mosquito Ae. albopictus is usually adapted to the peri-domestic environment and typically breeds outdoors. However, we observed its larvae in most containers within homes in northern peninsular Malaysia. To anticipate the epidemiological implications of this indoor-breeding, we assessed some fitness traits affecting vectorial capacity during colonization process. Specifically, we examined whether Ae. albopictus exhibits increased survival, gonotrophic activity and fecundity due to the potential increase in blood feeding opportunities. Methodology/Principal Findings In a series of experiments involving outdoors and indoors breeding populations, we found that Ae. albopictus lives longer in the indoor environment. We also observed increased nighttime biting activity and lifetime fecundity in indoor/domestic adapted females, although they were similar to recently colonized females in body size. Conclusion/Significance Taken together these data suggest that accommodation of Ae. albopictus to indoor/domestic environment may increase its lifespan, blood feeding success, nuisance and thus vectorial capacity (both in terms of increased vector-host contacts and vector population density). These changes in the breeding behavior of Ae. albopictus, a potential vector of several human pathogens including dengue viruses, require special attention. PMID:20668543
Correspondence between Children's Indoor and Outdoor Play in Japanese Preschool Daily Life
ERIC Educational Resources Information Center
Hirose, Toshiya; Koda, Naoko; Minami, Tetsuhiro
2012-01-01
This study examined the correspondence between children's indoor and outdoor play in a preschool environment to investigate whether the children maintained a tendency to engage in a particular type of play irrespective of the environment, or whether they changed the type of play according to the environment. Play behaviours of 18 three-year-old…
A first overview of textile fibers, including microplastics, in indoor and outdoor environments.
Dris, Rachid; Gasperi, Johnny; Mirande, Cécile; Mandin, Corinne; Guerrouache, Mohamed; Langlois, Valérie; Tassin, Bruno
2017-02-01
Studies about microplastics in various environments highlighted the ubiquity of anthropogenic fibers. As a follow-up of a recent study that emphasized the presence of man-made fibers in atmospheric fallout, this study is the first one to investigate fibers in indoor and outdoor air. Three different indoor sites were considered: two private apartments and one office. In parallel, the outdoor air was sampled in one site. The deposition rate of the fibers and their concentration in settled dust collected from vacuum cleaner bags were also estimated. Overall, indoor concentrations ranged between 1.0 and 60.0 fibers/m 3 . Outdoor concentrations are significantly lower as they range between 0.3 and 1.5 fibers/m 3 . The deposition rate of the fibers in indoor environments is between 1586 and 11,130 fibers/day/m 2 leading to an accumulation of fibers in settled dust (190-670 fibers/mg). Regarding fiber type, 67% of the analyzed fibers in indoor environments are made of natural material, primarily cellulosic, while the remaining 33% fibers contain petrochemicals with polypropylene being predominant. Such fibers are observed in marine and continental studies dealing with microplastics. The observed fibers are supposedly too large to be inhaled but the exposure may occur through dust ingestion, particularly for young children. Copyright © 2016 Elsevier Ltd. All rights reserved.
This diagram compliments the document, PCBs in Building Materials: Q's & A's, on how exposure to PCBs can be assessed and reduced in school buildings. It describes actions for reducing exposures to PCBs in indoor school building environments.
Feasibility analysis on the building environment of college dormitories in Baoding
NASA Astrophysics Data System (ADS)
Wang, Xinyi
2018-06-01
The quality of indoor air greatly affects people's health. As a place where college students live for a long time, the architectural environment is closely related to people's lives. In this paper, two cases of dormitory of the North China Electric Power University in Baoding are selected as the subject investigated. The environmental test and questionnaire method were used to study. The test indexes mainly include temperature, relative humidity and wind speeds. We obtain the basic situation of indoor thermal humidity environment, light environment and air velocity. Based on a series of tests, combined with subjective comfort and comprehensive evaluation, we analyzed the thermal comfort of indoor buildings, and put forward measures to further improve the building environment of College Dormitories under the principle of high efficiency and energy saving.
Meadow, J F; Altrichter, A E; Kembel, S W; Kline, J; Mhuireach, G; Moriyama, M; Northcutt, D; O'Connor, T K; Womack, A M; Brown, G Z; Green, J L; Bohannan, B J M
2014-02-01
Architects and engineers are beginning to consider a new dimension of indoor air: the structure and composition of airborne microbial communities. A first step in this emerging field is to understand the forces that shape the diversity of bioaerosols across space and time within the built environment. In an effort to elucidate the relative influences of three likely drivers of indoor bioaerosol diversity - variation in outdoor bioaerosols, ventilation strategy, and occupancy load - we conducted an intensive temporal study of indoor airborne bacterial communities in a high-traffic university building with a hybrid HVAC (mechanically and naturally ventilated) system. Indoor air communities closely tracked outdoor air communities, but human-associated bacterial genera were more than twice as abundant in indoor air compared with outdoor air. Ventilation had a demonstrated effect on indoor airborne bacterial community composition; changes in outdoor air communities were detected inside following a time lag associated with differing ventilation strategies relevant to modern building design. Our results indicate that both occupancy patterns and ventilation strategies are important for understanding airborne microbial community dynamics in the built environment. © 2013 The Authors. Indoor Air published by John Wiley & Sons Ltd.
Guo, Qiuju; Zhang, Lei; Guo, Lu
2012-12-01
The unattached fraction of radon progeny (f(p)) is one of the most important factors for accurate evaluation of the effective dose from a unit of radon exposure, and it may vary greatly in different environments. For precise evaluation of the indoor radon exposure dose and the influence of unattached radon progeny, a pilot survey of f(p) in different environments was carried out in China with a portable and integrating monitor. The dose conversion factors for radon progeny are calculated with LUDEP(®) code, and the dose contributions from the unattached and the attached radon progenies were simultaneously evaluated based on the results of field measurements. The results show that even though the concentrations of radon progeny vary significantly among different indoor environments, the variations of f(p) seem relatively small (9.3-16.9%). The dose contribution from unattached radon progeny is generally larger (30.2-46.2%) in an indoor environment.
NASA Astrophysics Data System (ADS)
Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.
2018-04-01
Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (p<0.05) than the total concentration of outdoor surface growing mould (209.91 CFU/cm2). Respectively, the mean concentration of indoor surface-growing mould (18920.13 CFU/cm2 for B1 and 3704.67 CFU/cm2 for B2) is significantly higher than their outdoor counterparts (99.95 CFU/cm2 for b1 and for 319.86 CFU/cm2 b2) at these buildings. Besides, various air quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.
An Office Building Occupants Guide to Indoor Air Quality - Printable Version
This guide is intended to help people who work in office buildings learn about the factors that contribute to indoor air quality and comfort problems and the roles of building managers and occupants in maintaining a good indoor environment.
THE INTERACTION OF VAPOUR PHASE ORGANIC COMPOUNDS WITH INDOOR SINKS
The interaction of indoor air pollutants with interior surfaces (i.e., sinks) is a well known, but poorly understood, phenomenon. Studies have shown that re-emissions of adsorbed organic vapours can contribute to elevated concentrations of organics in indoor environments. Researc...
SBS symptoms in relation to dampness and ventilation in inspected single-family houses in Sweden.
Smedje, Greta; Wang, Juan; Norbäck, Dan; Nilsson, Håkan; Engvall, Karin
2017-10-01
To investigate the relationships between symptoms compatible with the sick building syndrome (SBS) in adults and building dampness and ventilation in single-family houses. Within the Swedish BETSI study, a national sample of single-family houses were inspected by professional building experts, and adults living in the houses answered a questionnaire on SBS. Relationships between building factors and SBS were analysed using logistic regression. Of the respondents, 23% reported having had weekly SBS symptoms during the last three months. A large proportion of houses exhibited building or construction problems. In total, 40% of houses had dampness problems in the foundation, and this was related to a higher prevalence of both mucous and dermal symptoms, and any SBS symptoms. Furthermore, high air humidity was related to more symptoms, with the relationship with absolute humidity being stronger than that with relative humidity or moisture load. Symptoms were also more prevalent in houses with a high U value, reflecting a poor thermal insulation. Compared to natural ventilation, living in a house with mechanical supply and exhaust ventilation was related to a lower prevalence of general symptoms and any SBS symptoms, but there were only weak associations between measured air exchange rate and symptoms. A large proportion of single-family houses have dampness problems in the foundation, and pollutants may enter the living space of the house and affect the health of the occupants. Furthermore, absolute air humidity should be measured more often in indoor air studies.
Received Signal Strength Database Interpolation by Kriging for a Wi-Fi Indoor Positioning System
Jan, Shau-Shiun; Yeh, Shuo-Ju; Liu, Ya-Wen
2015-01-01
The main approach for a Wi-Fi indoor positioning system is based on the received signal strength (RSS) measurements, and the fingerprinting method is utilized to determine the user position by matching the RSS values with the pre-surveyed RSS database. To build a RSS fingerprint database is essential for an RSS based indoor positioning system, and building such a RSS fingerprint database requires lots of time and effort. As the range of the indoor environment becomes larger, labor is increased. To provide better indoor positioning services and to reduce the labor required for the establishment of the positioning system at the same time, an indoor positioning system with an appropriate spatial interpolation method is needed. In addition, the advantage of the RSS approach is that the signal strength decays as the transmission distance increases, and this signal propagation characteristic is applied to an interpolated database with the Kriging algorithm in this paper. Using the distribution of reference points (RPs) at measured points, the signal propagation model of the Wi-Fi access point (AP) in the building can be built and expressed as a function. The function, as the spatial structure of the environment, can create the RSS database quickly in different indoor environments. Thus, in this paper, a Wi-Fi indoor positioning system based on the Kriging fingerprinting method is developed. As shown in the experiment results, with a 72.2% probability, the error of the extended RSS database with Kriging is less than 3 dBm compared to the surveyed RSS database. Importantly, the positioning error of the developed Wi-Fi indoor positioning system with Kriging is reduced by 17.9% in average than that without Kriging. PMID:26343673
Received Signal Strength Database Interpolation by Kriging for a Wi-Fi Indoor Positioning System.
Jan, Shau-Shiun; Yeh, Shuo-Ju; Liu, Ya-Wen
2015-08-28
The main approach for a Wi-Fi indoor positioning system is based on the received signal strength (RSS) measurements, and the fingerprinting method is utilized to determine the user position by matching the RSS values with the pre-surveyed RSS database. To build a RSS fingerprint database is essential for an RSS based indoor positioning system, and building such a RSS fingerprint database requires lots of time and effort. As the range of the indoor environment becomes larger, labor is increased. To provide better indoor positioning services and to reduce the labor required for the establishment of the positioning system at the same time, an indoor positioning system with an appropriate spatial interpolation method is needed. In addition, the advantage of the RSS approach is that the signal strength decays as the transmission distance increases, and this signal propagation characteristic is applied to an interpolated database with the Kriging algorithm in this paper. Using the distribution of reference points (RPs) at measured points, the signal propagation model of the Wi-Fi access point (AP) in the building can be built and expressed as a function. The function, as the spatial structure of the environment, can create the RSS database quickly in different indoor environments. Thus, in this paper, a Wi-Fi indoor positioning system based on the Kriging fingerprinting method is developed. As shown in the experiment results, with a 72.2% probability, the error of the extended RSS database with Kriging is less than 3 dBm compared to the surveyed RSS database. Importantly, the positioning error of the developed Wi-Fi indoor positioning system with Kriging is reduced by 17.9% in average than that without Kriging.
Wilson, Aaron M; Luo, Wen; Miller, J David
2009-11-01
We are interested in isolating and identifying antigenic fungal proteins from species that grow on damp building materials. The indoor clade of Penicillium chrysogenum, the so-called Fleming clade, is the most common species of Penicillium on moldy building materials. We have identified a 52-kDa marker protein for the indoor clade of P. chrysogenum not present in a taxonomically diverse selection of fungi. It is found in high concentrations in protein extracted from the fungus grown on paper-faced gypsum wallboard. During this process, we illuminated the variability in response to patient sera and of strains of the fungus collected over a wide geographic area. From a collection of sera from all over the USA, 25 of the 48 patients reacted to the 52-kDa protein from this prescreened collection of sera. Most strain/antibody combinations had proportionate ELISA response associated with the presence of the target. However, approximately 25% of the strain/patient serum combinations included people who responded to many common allergens from the Penicillia. All the P. chrysogenum strains tested produced the target protein. However, there was considerable variability in patient IgG response to 32-, 30-, and 18-kDa antigens and in their production by the various clade 4 strains. The target protein was not found in spores or culture extracts of a wide selection of relevant fungi. It appears that the previous studies have been conducted on strains of the fungus from the three clades not those associated with the built environment.
Assessment of indoor PM2.5 in different residential environments
NASA Astrophysics Data System (ADS)
Yassin, Mohamed F.; AlThaqeb, Bothaina E. Y.; Al-Mutiri, Eman A. E.
2012-09-01
The indoor air quality (IAQ) as assessed by PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) was measured at indoor settings in various residential houses which were located in different local environments across Kuwait. The indoor house settings included kitchen, living room, and bedrooms. Samples were collected from houses over 24 h. PM2.5 was estimated using a Dust-Trak personal sampler. Results were analyzed and compared with the US Environmental Protection Agencies (EPA) and World Health Organization (WHO) standards and guidelines. The results demonstrated that kitchens have the highest PM2.5 concentration probably due to cooking activities; the bedroom has the lowest PM2.5 concentration. The study shows that Kuwait indoor residential pollution is among the worst in comparison with other countries.
Ozone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T; Zhang, J; Weschler, C J; Lioy, P J
2000-01-01
Little information currently exists regarding the occurrence of secondary organic aerosol formation in indoor air. Smog chamber studies have demonstrated that high aerosol yields result from the reaction of ozone with terpenes, both of which commonly occur in indoor air. However, smog chambers are typically static systems, whereas indoor environments are dynamic. We conducted a series of experiments to investigate the potential for secondary aerosol in indoor air as a result of the reaction of ozone with d-limonene, a compound commonly used in air fresheners. A dynamic chamber design was used in which a smaller chamber was nested inside a larger one, with air exchange occurring between the two. The inner chamber was used to represent a model indoor environment and was operated at an air exchange rate below 1 exchange/hr, while the outer chamber was operated at a high air exchange rate of approximately 45 exchanges/hr. Limonene was introduced into the inner chamber either by the evaporation of reagent-grade d-limonene or by inserting a lemon-scented, solid air freshener. A series of ozone injections were made into the inner chamber during the course of each experiment, and an optical particle counter was used to measure the particle concentration. Measurable particle formation and growth occurred almost exclusively in the 0.1-0.2 microm and 0.2-0.3 microm size fractions in all of the experiments. Particle formation in the 0.1-0.2 microm size range occurred as soon as ozone was introduced, but the formation of particles in the 0.2-0.3 microm size range did not occur until at least the second ozone injection occurred. The results of this study show a clear potential for significant particle concentrations to be produced in indoor environments as a result of secondary particle formation via the ozone-limonene reaction. Because people spend the majority of their time indoors, secondary particles formed in indoor environments may make a significant contribution to overall particle exposure. This study provides data for assessing the impact of outdoor ozone on indoor particles. This is important to determine the efficacy of the mass-based particulate matter standards in protecting public health because the indoor secondary particles can vary coincidently with the variations of outdoor fine particles in summer. PMID:11133393
Ozone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T; Zhang, J; Weschler, C J; Lioy, P J
2000-12-01
Little information currently exists regarding the occurrence of secondary organic aerosol formation in indoor air. Smog chamber studies have demonstrated that high aerosol yields result from the reaction of ozone with terpenes, both of which commonly occur in indoor air. However, smog chambers are typically static systems, whereas indoor environments are dynamic. We conducted a series of experiments to investigate the potential for secondary aerosol in indoor air as a result of the reaction of ozone with d-limonene, a compound commonly used in air fresheners. A dynamic chamber design was used in which a smaller chamber was nested inside a larger one, with air exchange occurring between the two. The inner chamber was used to represent a model indoor environment and was operated at an air exchange rate below 1 exchange/hr, while the outer chamber was operated at a high air exchange rate of approximately 45 exchanges/hr. Limonene was introduced into the inner chamber either by the evaporation of reagent-grade d-limonene or by inserting a lemon-scented, solid air freshener. A series of ozone injections were made into the inner chamber during the course of each experiment, and an optical particle counter was used to measure the particle concentration. Measurable particle formation and growth occurred almost exclusively in the 0.1-0.2 microm and 0.2-0.3 microm size fractions in all of the experiments. Particle formation in the 0.1-0.2 microm size range occurred as soon as ozone was introduced, but the formation of particles in the 0.2-0.3 microm size range did not occur until at least the second ozone injection occurred. The results of this study show a clear potential for significant particle concentrations to be produced in indoor environments as a result of secondary particle formation via the ozone-limonene reaction. Because people spend the majority of their time indoors, secondary particles formed in indoor environments may make a significant contribution to overall particle exposure. This study provides data for assessing the impact of outdoor ozone on indoor particles. This is important to determine the efficacy of the mass-based particulate matter standards in protecting public health because the indoor secondary particles can vary coincidently with the variations of outdoor fine particles in summer.
Report #12-P-0847, September 21, 2012.Our review of the security posture and in-place environmental controls of EPA’s Radiation and Indoor Environments National Laboratory computer room disclosed an array of security and environmental control deficiencies.
The U.S. Environmental Protection Agency (EPA) has established an ongoing effort to identify the major perfluorocarboxylic acid (PFCA) sources in nonoccupational indoor environments and characterize their transport and fate. This study determined the concentrations of perfluorote...
i-SVOC -- A simulation program for indoor SVOCs (Version 1.0)
Program i-SVOC estimates the emissions, transport, and sorption of semivolatile organic compounds (SVOCs) in the indoor environment as functions of time when a series of initial conditions is given. This program implements a framework for dynamic modeling of indoor SVOCs develope...
NASA Astrophysics Data System (ADS)
Pereira, Carlos; Chartois, Yannick; Pousset, Yannis; Vauzelle, Rodolphe
2006-09-01
Modelling of the environment is an important factor in electromagnetic wave propagation simulation, performed by a 3D ray-tracing method. The aim of this work is to study the effect of indoor environment modelling accuracy on MIMO (Multiple Input Multiple Output) channel characterisation. The first of the two environments investigated is the hall of our building, while the second one is a more confined environment and represents the floor of our laboratory. For these two indoor environments, three description levels are proposed in order to establish geometrical and electrical modelling impact on MIMO channel characterisation. Results are obtained by analysing the capacity and variation in correlation in relation to the polarisation, the presence of LOS (Line of sight) or NLOS configurations, the spacing between antennae and the number of transmitter and receiver antennae. To cite this article: C. Pereira et al., C. R. Physique 7 (2006).
Occupant perception of indoor air and comfort in four hospitality environments.
Moschandreas, D J; Chu, P
2002-01-01
This article reports on a survey of customer and staff perceptions of indoor air quality at two restaurants, a billiard hall, and a casino. The survey was conducted at each environment for 8 days: 2 weekend days on 2 consecutive weekends and 4 weekdays. Before and during the survey, each hospitality environment satisfied ventilation requirements set in ASHRAE Standard 62-1999, Ventilation for Acceptable Indoor Air. An objective of this study was to test the hypothesis: If a hospitality environment satisfies ASHRAE ventilation requirements, then the indoor air is acceptable, that is, fewer than 20% of the exposed occupants perceive the environment as unacceptable. A second objective was to develop a multiple regression model that predicts the dependent variable, the environment is acceptable, as a function of a number of independent perception variables. Occupant perception of environmental, comfort, and physical variables was measured using a questionnaire. This instrument was designed to be efficient and unobtrusive; subjects could complete it within 3 min. Significant differences of occupant environment perception were identified among customers and staff. The dependent variable, the environment is acceptable, is affected by temperature, occupant density, and occupant smoking status, odor perception, health conditions, sensitivity to chemicals, and enjoyment of activities. Depending on the hospitality environment, variation of independent variables explains as much as 77% of the variation of the dependent variable.
Equivalent Viscous Damping Methodologies Applied on VEGA Launch Vehicle Numerical Model
NASA Astrophysics Data System (ADS)
Bartoccini, D.; Di Trapani, C.; Fransen, S.
2014-06-01
Part of the mission analysis of a spacecraft is the so- called launcher-satellite coupled loads analysis which aims at computing the dynamic environment of the satellite and of the launch vehicle for the most severe load cases in flight. Evidently the damping of the coupled system shall be defined with care as to not overestimate or underestimate the loads derived for the spacecraft. In this paper the application of several EqVD (Equivalent Viscous Damping) for Craig an Bampton (CB)-systems are investigated. Based on the structural damping defined for the various materials in the parent FE-models of the CB-components, EqVD matrices can be computed according to different methodologies. The effect of these methodologies on the numerical reconstruction of the VEGA launch vehicle dynamic environment will be presented.
Variation of the unattached fraction of radon progeny and its contribution to radon exposure.
Guo, Lu; Zhang, Lei; Guo, Qiuju
2016-06-01
The unattached fraction of radon progeny is one of the most important factors for radon exposure evaluation through the dosimetric approach. To better understand its level and variation in the real environment, a series of field measurements were carried out indoors and outdoors, and radon equilibrium equivalent concentration was also measured. The dose contribution of unattached radon progeny was evaluated in addition. The results show that no clear variation trend of the unattached fraction of radon progeny is observed in an indoor or outdoor environment. The average unattached fraction of radon progeny for the indoors and outdoors are (8.7 ± 1.6)% and (9.7 ± 2.1)%, respectively. The dose contribution of unattached radon progeny to total radon exposure is some 38.8% in an indoor environment, suggesting the importance of the evaluation on unattached radon progeny.
Li, I-Hsum; Chen, Ming-Chang; Wang, Wei-Yen; Su, Shun-Feng; Lai, To-Wen
2014-01-27
A single-webcam distance measurement technique for indoor robot localization is proposed in this paper. The proposed localization technique uses webcams that are available in an existing surveillance environment. The developed image-based distance measurement system (IBDMS) and parallel lines distance measurement system (PLDMS) have two merits. Firstly, only one webcam is required for estimating the distance. Secondly, the set-up of IBDMS and PLDMS is easy, which only one known-dimension rectangle pattern is needed, i.e., a ground tile. Some common and simple image processing techniques, i.e., background subtraction are used to capture the robot in real time. Thus, for the purposes of indoor robot localization, the proposed method does not need to use expensive high-resolution webcams and complicated pattern recognition methods but just few simple estimating formulas. From the experimental results, the proposed robot localization method is reliable and effective in an indoor environment.
Zuo, Wangda; Wetter, Michael; Tian, Wei; ...
2015-07-13
Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation ofmore » the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.« less
Li, I-Hsum; Chen, Ming-Chang; Wang, Wei-Yen; Su, Shun-Feng; Lai, To-Wen
2014-01-01
A single-webcam distance measurement technique for indoor robot localization is proposed in this paper. The proposed localization technique uses webcams that are available in an existing surveillance environment. The developed image-based distance measurement system (IBDMS) and parallel lines distance measurement system (PLDMS) have two merits. Firstly, only one webcam is required for estimating the distance. Secondly, the set-up of IBDMS and PLDMS is easy, which only one known-dimension rectangle pattern is needed, i.e., a ground tile. Some common and simple image processing techniques, i.e., background subtraction are used to capture the robot in real time. Thus, for the purposes of indoor robot localization, the proposed method does not need to use expensive high-resolution webcams and complicated pattern recognition methods but just few simple estimating formulas. From the experimental results, the proposed robot localization method is reliable and effective in an indoor environment. PMID:24473282
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Wangda; Wetter, Michael; Tian, Wei
Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation ofmore » the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.« less
Bohlin, Pernilla; Audy, Ondřej; Škrdlíková, Lenka; Kukučka, Petr; Vojta, Šimon; Přibylová, Petra; Prokeš, Roman; Čupr, Pavel; Klánová, Jana
2014-11-01
Indoor air pollution has been recognized as an important risk factor for human health, especially in areas where people tend to spend most of their time indoors. Many semi-volatile organic compounds (SVOCs) have primarily indoor sources and are present in orders of magnitude higher concentrations indoors than outdoors. Despite this, awareness of SVOCs in indoor air and assessment of the link between indoor concentrations and human health have lagged behind those of outdoor air. This is partially related to challenges associated with indoor sampling of SVOCs. Passive air samplers (PASs), which are widely accepted in established outdoor air monitoring networks, have been used to fill the knowledge gaps on indoor SVOCs distribution. However, their applicability for indoor environments and the assessment of human health risks lack sufficient experimental data. To address this issue, we performed an indoor calibration study of polyurethane foam (PUF) PAS deployed in a double-dome chamber, covering both legacy and new SVOC classes. PUF-PAS and a continuous low-volume active air sampler (AAS) were co-deployed for a calibration period of twelve weeks. Based on the results from this evaluation, PUF-PAS in a double-bowl chamber is recommended for indoor sampling and health risk assessment of gas phase SVOCs, including novel brominated flame retardants (nBFR) providing sufficient exposure time is applied. Data for particle associated SVOCs suffered from significant uncertainties caused by low level of detection and low precision in this study. A more open chamber design for indoor studies may allow for higher sampling rates (RS) and better performance for the particle associated SVOCs.
Indoor airborne particle sources and outdoor haze days effect in urban office areas in Guangzhou.
Zhang, Manwen; Zhang, Sukun; Feng, Guixian; Su, Hui; Zhu, Fengzhi; Ren, Mingzhong; Cai, Zongwei
2017-04-01
To identify the sources of PM 2.5 pollutants in work environments and determine whether the air quality inside an office was affected by a change in outdoor pollution status, concurrent indoor and outdoor measurements of PM 2.5 were conducted at five different office spaces in the urban center of Guangzhou on low pollution days (non-episode days, NEDs), and high pollution days (haze episode days, EDs). Indoor-outdoor relationships between the PM 2.5 mass and its chemical constituents, which included water-soluble ions, carbonaceous species, and metal elements, were investigated. A principle component analysis (PCA) was performed to further confirm the relationship between the indoor and outdoor PM 2.5 pollution. The results reveal that (1) Printing and ETS (Environmental tobacco smoking) were found to be important office PM 2.5 sources and associated with the enrichment of SO 4 2- , OC, EC and some toxic metals indoors; (2) On EDs, serious outdoor pollution and higher air exchange rate greatly affected all studied office environments, masking the original differences of the indoor characteristics (3) Fresh air system could efficiently filter out most of the outside pollutants on both NEDs and EDs. Overall, the results of our study suggest that improper human behavior is associated with the day-to-day generation of indoor PM 2.5 levels and sporadic outdoor pollution events can lead to poor indoor air quality in urban office environments. Moreover, fresh air system has been experimentally proved with data as an effective way to improve the air quality in office. Copyright © 2016. Published by Elsevier Inc.
Damping treatment for an aircraft hard-mounted antenna system in a vibroacoustic environment
NASA Astrophysics Data System (ADS)
Tate, Ralph E.; Rupert, Carl L.
1990-10-01
This paper discusses the design, analysis, and testing of 'add-on' damping treatments for the Band 6, 7, 8 radar antenna packages that are hard-mounted on the B-1B Aft Equipment Bay (AEB) where equipment failures are routinely occurring during take-off maneuvers at maximum throttle settings. This damage results from the intense vibroacoustical environment generated by the three-stage afterburning engines. Failure rates have been sufficiently high to warrant a 'quick fix' involving damping treatments that can be installed in a short time with minimal modification to the existing structure.
Richter, Jens Christian; Jakobsson, Kristina; Taj, Tahir; Oudin, Anna
2018-01-01
Atopic disorders are a global concern. Studies in migrant populations can illuminate the interplay of genetic and environmental factors. Exposures related to bad housing (indoor dampness, mould growth, crowding etc.) are likely to play a role in how socioeconomic inequalities can turn into health disparities for disadvantaged populations. The sizable immigrant population living in very poor-quality housing in Malmö, Sweden, became the focus of a cross-sectional study. To describe atopic disorders and sensitizations in a population living in substandard housing in Malmö, Sweden, with an emphasis on their relation to harmful exposures from the built environment. Families were recruited via identification of any children with symptomatic airway afflictions from health care records, and also asymptomatic children from school lists. Interviewer-led health questionnaire data and data from self-reports about living conditions were obtained together with data from home inspections carried out by health communicators. Families underwent skin prick tests (SPT) against common aeroallergens. As could be expected from background demographic information, it turned out that we effectively studied an immigrant population inhabiting very precarious housing outside the center of Malmö. A total of 359 children from 130 families (total 650 participants) were included. Overall the prevalence of potentially harmful environmental exposures was high (signs of moisture or mould in more than 50% of apartments, indoor smoking in 37% of households). Atopic disorders were common among both adults and children. SPTs showed a spectrum of sensitizations consistent with unselected populations in Sweden. Paternal sensitization in the SPT was associated with higher risk of sensitization for offspring than maternal sensitization. Few statistically significant associations of atopic sensitization with studied environmental exposures were detected (for example objective signs of dampness /mould in bathrooms). There were marked discrepancies between asthma diagnoses obtained from the health records and parental reports of such diagnoses and treatment for their children. The atopic burden in this selected immigrant population was high, and results point to unmet medical needs. Health care systems caring for such populations need to be aware of their specific health needs; comprehensive asthma and allergy care should include consideration of harmful environmental exposures, adhering to the precautionary principle.
Exposures from indoor environments are a major issue for evaluating total long-term personal exposures to the fine fraction (
Biocontaminants such as some mold spores or pollen grains, because of their size and mass, settle rapidly within the indoor environment. Over time the...
Latex paints are widely used in residential and commercial indoor environments. The surface areas covered by the paints in these environments are relatively large. Thus, latex paints have the potential for having a major impact on indoor air quality (IAQ). A study was undertaken ...
Determination of indoor exposure levels commonly involves assumptions of fully mixed ventilation conditions. In the effort to determine contaminant levels with efficiency, the nodal approach is common in modeling of the indoor environment. To quantify the transport phenomenon or ...
Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino
2015-01-01
Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth. This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®), 70% ethanol, vinegar (4.0%−4.2% acetic acid), and a plant-derived compound (tea tree (Melaleuca alternifolia) oil) tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum), which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%–4.2% acetic acid) was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to inhibit the growth of fungal genera found in the indoor air environment. The results indicate that tea tree oil was the most effective antifungal agent tested, and may have industrial application for the remediation of fungal contamination in residential and occupational buildings. PMID:26042369
Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino
2015-06-02
Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth. This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®), 70% ethanol, vinegar (4.0%-4.2% acetic acid), and a plant-derived compound (tea tree (Melaleuca alternifolia) oil) tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum), which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%-4.2% acetic acid) was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to inhibit the growth of fungal genera found in the indoor air environment. The results indicate that tea tree oil was the most effective antifungal agent tested, and may have industrial application for the remediation of fungal contamination in residential and occupational buildings.
40 CFR 61.205 - Distribution and use of phosphogypsum for indoor research and development.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for indoor research and development. 61.205 Section 61.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR... and use of phosphogypsum for indoor research and development. (a) Phosphogypsum may be lawfully...
40 CFR 61.205 - Distribution and use of phosphogypsum for indoor research and development.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for indoor research and development. 61.205 Section 61.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR... and use of phosphogypsum for indoor research and development. (a) Phosphogypsum may be lawfully...
RISK ASSESSMENT/RISK MANAGEMENT FOR INDOOR MOLD
In 1998, a team of eight EPA researchers from NERL, NHEERL, NRMRL and NCEA organized to examine the role of indoor molds/fungi in children's health. The make-up of the indoor environment is critical to the health of children in general and has a particularly important influence ...
Particle size distributions were measured indoors and outdoors of six residences in the Raleigh-Durham-Chapel Hill, NC area to characterize the factors affecting particle concentrations in the indoor environment, including infiltration of outdoor aerosols. Size resolved partic...
Impact of climate change on the domestic indoor environment and associated health risks in the UK.
Vardoulakis, Sotiris; Dimitroulopoulou, Chrysanthi; Thornes, John; Lai, Ka-Man; Taylor, Jonathon; Myers, Isabella; Heaviside, Clare; Mavrogianni, Anna; Shrubsole, Clive; Chalabi, Zaid; Davies, Michael; Wilkinson, Paul
2015-12-01
There is growing evidence that projected climate change has the potential to significantly affect public health. In the UK, much of this impact is likely to arise by amplifying existing risks related to heat exposure, flooding, and chemical and biological contamination in buildings. Identifying the health effects of climate change on the indoor environment, and risks and opportunities related to climate change adaptation and mitigation, can help protect public health. We explored a range of health risks in the domestic indoor environment related to climate change, as well as the potential health benefits and unintended harmful effects of climate change mitigation and adaptation policies in the UK housing sector. We reviewed relevant scientific literature, focusing on housing-related health effects in the UK likely to arise through either direct or indirect mechanisms of climate change or mitigation and adaptation measures in the built environment. We considered the following categories of effect: (i) indoor temperatures, (ii) indoor air quality, (iii) indoor allergens and infections, and (iv) flood damage and water contamination. Climate change may exacerbate health risks and inequalities across these categories and in a variety of ways, if adequate adaptation measures are not taken. Certain changes to the indoor environment can affect indoor air quality or promote the growth and propagation of pathogenic organisms. Measures aimed at reducing greenhouse gas emissions have the potential for ancillary public health benefits including reductions in health burdens related heat and cold, indoor exposure to air pollution derived from outdoor sources, and mould growth. However, increasing airtightness of dwellings in pursuit of energy efficiency could also have negative effects by increasing concentrations of pollutants (such as PM2.5, CO and radon) derived from indoor or ground sources, and biological contamination. These effects can largely be ameliorated by mechanical ventilation with heat recovery (MVHR) and air filtration, where such solution is feasible and when the system is properly installed, operated and maintained. Groups at high risk of these adverse health effects include the elderly (especially those living on their own), individuals with pre-existing illnesses, people living in overcrowded accommodation, and the socioeconomically deprived. A better understanding of how current and emerging building infrastructure design, construction, and materials may affect health in the context of climate change and mitigation and adaptation measures is needed in the UK and other high income countries. Long-term, energy efficient building design interventions, ensuring adequate ventilation, need to be promoted. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Damping MEMS Devices in Harsh Environments Using Active Thin Films
2008-06-17
properties of the layers was developed. Damping properties in Nitinol thin film due only to residual stresses was measured to be as high as tan delta...0.17 for large strain (0.9%). At lower strain levels a Nitinol /Silicon laminate was tested in a cantilever load frame. The damping value of the...film was measured to be 0.28 (at 0.27% strain). A Nitinol /Terfenol-D/Nickel laminate was fabricated and tested in a cantilever loading. The damping
Impact of indoor environment on path loss in body area networks.
Hausman, Sławomir; Januszkiewicz, Łukasz
2014-10-20
In this paper the influence of an example indoor environment on narrowband radio channel path loss for body area networks operating around 2.4 GHz is investigated using computer simulations and on-site measurements. In contrast to other similar studies, the simulation model included both a numerical human body phantom and its environment-room walls, floor and ceiling. As an example, radio signal attenuation between two different configurations of transceivers with dipole antennas placed in a direct vicinity of a human body (on-body scenario) is analyzed by computer simulations for several types of reflecting environments. In the analyzed case the propagation environments comprised a human body and office room walls. As a reference environment for comparison, free space with only a conducting ground plane, modelling a steel mesh reinforced concrete floor, was chosen. The transmitting and receiving antennas were placed in two on-body configurations chest-back and chest-arm. Path loss vs. frequency simulation results obtained using Finite Difference Time Domain (FDTD) method and a multi-tissue anthropomorphic phantom were compared to results of measurements taken with a vector network analyzer with a human subject located in an average-size empty cuboidal office room. A comparison of path loss values in different environments variants gives some qualitative and quantitative insight into the adequacy of simplified indoor environment model for the indoor body area network channel representation.
Rösch, Carolin; Wissenbach, Dirk K; von Bergen, Martin; Franck, Ulrich; Wendisch, Manfred; Schlink, Uwe
2015-09-01
Atmospheric ozone-terpene reactions, which form secondary organic aerosol (SOA) particles, can affect indoor air quality when outdoor air mixes with indoor air during ventilation. This study, conducted in Leipzig, Germany, focused on limonene-induced particle formation in a genuine indoor environment (24 m(3)). Particle number, limonene and ozone concentrations were monitored during the whole experimental period. After manual ventilation for 30 min, during which indoor ozone levels reached up to 22.7 ppb, limonene was introduced into the room at concentrations of approximately 180 to 250 μg m(-3). We observed strong particle formation and growth within a diameter range of 9 to 50 nm under real-room conditions. Larger particles with diameters above 100 nm were less affected by limonene introduction. The total particle number concentrations (TPNCs) after limonene introduction clearly exceed outdoor values by a factor of 4.5 to 41 reaching maximum concentrations of up to 267,000 particles cm(-3). The formation strength was influenced by background particles, which attenuated the formation of new SOA with increasing concentration, and by ozone levels, an increase of which by 10 ppb will result in a six times higher TPNC. This study emphasizes indoor environments to be preferred locations for particle formation and growth after ventilation events. As a consequence, SOA formation can produce significantly higher amounts of particles than transported by ventilation into the indoor air.
Health Effects of PCBs in Residences and Schools (HESPERUS): PCB – health Cohort Profile
Bräuner, Elvira Vaclavik; Andersen, Zorana Jovanovic; Frederiksen, Marie; Specht, Ina Olmer; Hougaard, Karin Sørig; Ebbehøj, Niels; Bailey, Janice; Giwercman, Aleksander; Steenland, Kyle; Longnecker, Matthew Paul; Bonde, Jens Peter
2016-01-01
Polychlorinated-biphenyls (PCBs) were introduced in the late 1920s and used until the 1970s when they were banned in most countries due to evidence of environmental build-up and possible adverse health effects. However they still persist in the environment, indoors and in humans. Indoor air in contaminated buildings may confer airborne exposure markedly above background regional PCB levels. To date, no epidemiological studies have assessed the health effects from exposure to semi-volatile PCBs in the indoor environment. Indoor air PCBs are generally less chlorinated than PCBs that are absorbed via the diet, or via past occupational exposure; therefore their health effects require separate risk assessment. Two separate cohorts of individuals who have either attended schools (n = 66,769; 26% exposed) or lived in apartment buildings (n = 37,185; 19% exposed), where indoor air PCB concentrations have been measured were created. An individual estimate of long-term airborne PCB exposure was assigned based on measurements. The cohorts will be linked to eight different national data sources on mortality, school records, residential history, socioeconomic status, and chronic disease and reproductive outcomes. The linking of indoor air exposures with health outcomes provides a dataset unprecedented worldwide. We describe a project, called HESPERUS (Health Effects of PCBs in Residences and Schools), which will be the first study of the long term health effects of the lower-chlorinated, semi-volatile PCBs in the indoor environment. PMID:27090775
Health Effects of PCBs in Residences and Schools (HESPERUS): PCB - health Cohort Profile.
Bräuner, Elvira Vaclavik; Andersen, Zorana Jovanovic; Frederiksen, Marie; Specht, Ina Olmer; Hougaard, Karin Sørig; Ebbehøj, Niels; Bailey, Janice; Giwercman, Aleksander; Steenland, Kyle; Longnecker, Matthew Paul; Bonde, Jens Peter
2016-04-19
Polychlorinated-biphenyls (PCBs) were introduced in the late 1920s and used until the 1970s when they were banned in most countries due to evidence of environmental build-up and possible adverse health effects. However they still persist in the environment, indoors and in humans. Indoor air in contaminated buildings may confer airborne exposure markedly above background regional PCB levels. To date, no epidemiological studies have assessed the health effects from exposure to semi-volatile PCBs in the indoor environment. Indoor air PCBs are generally less chlorinated than PCBs that are absorbed via the diet, or via past occupational exposure; therefore their health effects require separate risk assessment. Two separate cohorts of individuals who have either attended schools (n = 66,769; 26% exposed) or lived in apartment buildings (n = 37,185; 19% exposed), where indoor air PCB concentrations have been measured were created. An individual estimate of long-term airborne PCB exposure was assigned based on measurements. The cohorts will be linked to eight different national data sources on mortality, school records, residential history, socioeconomic status, and chronic disease and reproductive outcomes. The linking of indoor air exposures with health outcomes provides a dataset unprecedented worldwide. We describe a project, called HESPERUS (Health Effects of PCBs in Residences and Schools), which will be the first study of the long term health effects of the lower-chlorinated, semi-volatile PCBs in the indoor environment.
Metabolites of Trichoderma species isolated from damp building materials.
McMullin, David R; Renaud, Justin B; Barasubiye, Tharcisse; Sumarah, Mark W; Miller, J David
2017-07-01
Buildings that have been flooded often have high concentrations of Trichoderma spores in the air while drying. Inhaled spores and spore and mycelial fragments contain large amounts of fungal glucan and natural products that contribute to the symptoms associated with indoor mould exposures. In this study, we considered both small molecules and peptaibol profiles of T. atroviride, T. koningiopsis, T. citrinoviride, and T. harzianum strains obtained from damp buildings in eastern Canada. Twenty-residue peptaibols and sorbicillin-derived metabolites (1-6) including a new structure, (R)-vertinolide (1), were characterized from T. citrinoviride. Trichoderma koningiopsis produced several koninginins (7-10), trikoningin KA V, and the 11-residue lipopeptaibols trikoningin KB I and trikoningin KB II. Trichoderma atroviride biosynthesized a mixture of 19-residue trichorzianine-like peptaibols, whereas T. harzianum produced 18-residue trichokindin-like peptaibols and the 11-residue harzianin HB I that was subsequently identified from the studied T. citrinoviride strain. Two α-pyrones, 6-pentyl-pyran-2-one (11) and an oxidized analog (12), were produced by both T. atroviride and T. harzianum. Aside from exposure to low molecular weight natural products, inhalation of Trichoderma spores and mycelial fragments may result in exposure to membrane-disrupting peptaibols. This investigation contributes to a more comprehensive understanding of the biologically active natural products produced by fungi commonly found in damp buildings.
Zhu, Yue-Shan; Yang, Wan-Dong; Li, Xiu-Wen; Ni, Hong-Gang; Zeng, Hui
2018-02-01
The quality of indoor environments has a significant impact on public health. Usually, an indoor environment is treated as a static box, in which physicochemical reactions of indoor air contaminants are negligible. This results in conservative estimates for primary indoor air pollutant concentrations, while also ignoring secondary pollutants. Thus, understanding the relationship between indoor and outdoor particles and particle-bound pollutants is of great significance. For this reason, we collected simultaneous indoor and outdoor measurements of the size distribution of airborne brominated flame retardant (BFR) congeners. The time-dependent concentrations of indoor particles and particle-bound BFRs were then estimated with the mass balance model, accounting for the outdoor concentration, indoor source strength, infiltration, penetration, deposition and indoor resuspension. Based on qualitative observation, the size distributions of ΣPBDE and ΣHBCD were characterized by bimodal peaks. According to our results, particle-bound BDE209 and γ-HBCD underwent degradation. Regardless of the surface adsorption capability of particles and the physicochemical properties of the target compounds, the concentration of BFRs in particles of different size fractions seemed to be governed by the particle distribution. Based on our estimations, for airborne particles and particle-bound BFRs, a window-open ventilated room only takes a quarter of the time to reach an equilibrium between the concentration of pollutants inside and outside compared to a closed room. Unfortunately, indoor pollutants and outdoor pollutants always exist simultaneously, which poses a window-open-or-closed dilemma to achieve proper ventilation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrison, G.C.; Corsi, R.L.; Destaillats, H.
2006-05-01
Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.
Interior shadings for office indoor visual comfort in humid climate region
NASA Astrophysics Data System (ADS)
Dinapradipta, Asri; Sudarma, Erwin; Defiana, Ima; Erwindi, Collinthia
2018-03-01
As part of the fenestration system, the interior shadings have also a role to control the indoor environment to maintain indoor visual comfort. As the occupants have personal access to control these, their control behavior then, might enhance or even worsen indoor comfort performance. The controlling behavior might not only influence indoor comfort performance but can also indicate the success or failure of interior shading as a control device element. This paper is intended to report control behavior patterns, as represented by the variety of the slats’ openings of two types of interior shading i.e. Venetian and Vertical blinds and to analyze these on the concurrent impacts to indoor office building’s indoor illuminance and luminance distribution. The purpose of this research is to figure out the shading control patterns as well as to examine the effectiveness of these two types of interior shadings to control indoor visual environment. This study is a quantitative research using experimentation on the slats’ opening of two types of shadings at two identical office rooms. The research results suggested that both types of blinds seem unsuitable for gaining proper illumination values at work planes in humid tropics area. However, these shadings demonstrate good performance for luminance distribution except for that of the closed Venetian blinds.
Hernández, Noelia; Ocaña, Manuel; Alonso, Jose M; Kim, Euntai
2017-01-13
Although much research has taken place in WiFi indoor localization systems, their accuracy can still be improved. When designing this kind of system, fingerprint-based methods are a common choice. The problem with fingerprint-based methods comes with the need of site surveying the environment, which is effort consuming. In this work, we propose an approach, based on support vector regression, to estimate the received signal strength at non-site-surveyed positions of the environment. Experiments, performed in a real environment, show that the proposed method could be used to improve the resolution of fingerprint-based indoor WiFi localization systems without increasing the site survey effort.
Hernández, Noelia; Ocaña, Manuel; Alonso, Jose M.; Kim, Euntai
2017-01-01
Although much research has taken place in WiFi indoor localization systems, their accuracy can still be improved. When designing this kind of system, fingerprint-based methods are a common choice. The problem with fingerprint-based methods comes with the need of site surveying the environment, which is effort consuming. In this work, we propose an approach, based on support vector regression, to estimate the received signal strength at non-site-surveyed positions of the environment. Experiments, performed in a real environment, show that the proposed method could be used to improve the resolution of fingerprint-based indoor WiFi localization systems without increasing the site survey effort. PMID:28098773
Research of cartographer laser SLAM algorithm
NASA Astrophysics Data System (ADS)
Xu, Bo; Liu, Zhengjun; Fu, Yiran; Zhang, Changsai
2017-11-01
As the indoor is a relatively closed and small space, total station, GPS, close-range photogrammetry technology is difficult to achieve fast and accurate indoor three-dimensional space reconstruction task. LIDAR SLAM technology does not rely on the external environment a priori knowledge, only use their own portable lidar, IMU, odometer and other sensors to establish an independent environment map, a good solution to this problem. This paper analyzes the Google Cartographer laser SLAM algorithm from the point cloud matching and closed loop detection. Finally, the algorithm is presented in the 3D visualization tool RViz from the data acquisition and processing to create the environment map, complete the SLAM technology and realize the process of indoor threedimensional space reconstruction
Faggioli, A; Capasso, L
2015-01-01
Indoor environment is one of major health determinants, and the regulations that set the sanitary requirements are of primary importance for the protection of public health. The authors analyse the critical aspects of the complex Italian regulatory system, starting from the EU regulations, through national and regional laws, and finally the municipal regulations. They underline the need for more uniformity and clarity in the determination of health standards, as well as for a simplification of the existing legislation. Moreover, they highlight the importance of controlling and monitoring indoor environment, currently almost completely absent in Italy due to the effects of the regulatory changes of the latest years.
NASA Astrophysics Data System (ADS)
Bartolomei, V.; Gomez Alvarez, E.; Glor, M.; Gligorovski, S.; Temime-Roussel, B.; Quivet, E.; Strekowski, R.; Zetzsch, C.; Held, A. B.; Wortham, H.
2013-12-01
Hydroxyl radical (OH) is one of the most important oxidant species in the atmosphere controlling its self-oxidizing capacity. The main sources of OH radicals are photolysis of ozone and photolysis of nitrous acid (HONO), among the others. In the indoor air, the ozonolysis of alkenes has been suggested as the main OH formation pathway. The possibility for OH formation through photolytic pathways in the indoor environment has been, up to now, ignored (Gómez Alvarez et al., 2012). Models and indirect measurements to the present time predicted concentrations of OH radicals in the order of 104 -105 cm-3. Recently, by direct measurements we have detected high OH radical concentrations of 1.8 106 cm-3 in a classroom in Marseille and we demonstrated that its main source is the photolysis of HONO (Gómez Alvarez et al., 2013). The concentrations of HONO are quite high indoors, reaching levels in the order of a few tens of ppbV (Gómez Alvarez et al., 2013). This is mainly due to 1) direct combustion sources and 2) heterogeneous reactions of NO2 on the numerous surfaces present in the indoor environment. HONO levels of 30 ppb were measured in a previous campaign carried out in Bayreuth in July 2012 as direct emissions from the combustion of a candle. The combination between so high concentrations of HONO and higher than expected light transmissions indoors (or indoor artificial lighting) could have a significant impact on the OH concentrations indoors which could feasibly become considerably higher than we measured in our school campaign (Gomez Alvarez et al., 2013). In order to evaluate these upper limits under combustion conditions in the indoor environment, we have carried out a campaign in the LOTASC chamber (Bayreuth, Germany). For this aim, the exhaust fumes from the burning of a commonly used domestic candle have been introduced in the chamber. The chamber was irradiated under well research indoor lighting conditions. A thorough characterization of light intensities and span (wavelength distribution) indoors have been performed, which had been identified as a clear flaw in our knowledge restricting the advancement of indoor air quality models. OH concentration levels have been determined using d9-butanol as tracer, using the OH clock determination procedure by PTR-MS-TOF. The OH radical concentration was investigated using different light intensities representative from indoor conditions, both natural and artificial and also different levels of RH. The PSS model has been performed in order to evaluate the contribution of different sources to the OH radical concentrations indoors under these conditions. The obtained results from the PSS model clearly indicate that the main source of OH radical indoors under combustion conditions is the photolysis of HONO under typical indoor irradiation conditions. REFERENCES Gómez Alvarez E, Wortham H, Strekowski R, Zetzsch C, Gligorovski S (2012) Atmospheric photo-sensitized heterogeneous and multiphase reactions: From outdoors to indoors, Environ. Sci. Technol. 46, 1955-1963. Gómez Alvarez, E.; Amedro, D.; Afif, C. ; Gligorovski, S.; Schoemacker , C.; Fittschen, C. ; Doussin, J. F.; Wortham, H. (2013) Unexpectedly high indoor hydroxyl radical concentrations associated with nitrous acid. Proc. Natl. Acad. Sci. USA Accepted.
ERIC Educational Resources Information Center
Lancioni, Giulio E.; O'Reilly, Mark F.; Singh, Nirbhay N.; Sigafoos, Jeff; Campodonico, Francesca; Oliva, Doretta
2009-01-01
Persons with profound visual impairments and other disabilities, such as neuromotor and intellectual disabilities, may encounter serious orientation and mobility problems even in familiar indoor environments, such as their homes. Teaching these persons to develop maps of their daily environment, using miniature replicas of the areas or some…
Knowledge of the Effects of Indoor Air Quality on Health among Women in Jordan
ERIC Educational Resources Information Center
Madanat, Hala; Barnes, Michael D.; Cole, Eugene C.
2008-01-01
Objective: To assess the extent of knowledge about symptoms relating to respiratory illnesses and home environments among a random sample of 200 urban Jordanian women. Method: This customized, validated, cross-sectional questionnaire evaluated the knowledge of these women about the association between the indoor environment and health, the…
Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju
2015-01-01
Indoor location-based services (iLBS) are extremely dynamic and changeable, and include numerous resources and mobile devices. In particular, the network infrastructure requires support for high scalability in the indoor environment, and various resource lookups are requested concurrently and frequently from several locations based on the dynamic network environment. A traditional map-based centralized approach for iLBSs has several disadvantages: it requires global knowledge to maintain a complete geographic indoor map; the central server is a single point of failure; it can also cause low scalability and traffic congestion; and it is hard to adapt to a change of service area in real time. This paper proposes a self-organizing and fully distributed platform for iLBSs. The proposed self-organizing distributed platform provides a dynamic reconfiguration of locality accuracy and service coverage by expanding and contracting dynamically. In order to verify the suggested platform, scalability performance according to the number of inserted or deleted nodes composing the dynamic infrastructure was evaluated through a simulation similar to the real environment. PMID:26016908
Energy, Weatherization and Indoor Air Quality
Climate change presents many challenges, including the production of severe weather events. These events and efforts to minimize their effects through weatherization can adversely affect indoor environments.
NASA Astrophysics Data System (ADS)
Kraus, Michal; Juhásová Šenitková, Ingrid
2017-10-01
Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users’ health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [μg/m3]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [°C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10µg/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.
An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture
Marques, Gonçalo; Pitarma, Rui
2016-01-01
The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants’ wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment. PMID:27869682
An Indoor Monitoring System for Ambient Assisted Living Based on Internet of Things Architecture.
Marques, Gonçalo; Pitarma, Rui
2016-11-17
The study of systems and architectures for ambient assisted living (AAL) is undoubtedly a topic of great relevance given the aging of the world population. The AAL technologies are designed to meet the needs of the aging population in order to maintain their independence as long as possible. As people typically spend more than 90% of their time in indoor environments, indoor air quality (iAQ) is perceived as an imperative variable to be controlled for the inhabitants' wellbeing and comfort. Advances in networking, sensors, and embedded devices have made it possible to monitor and provide assistance to people in their homes. The continuous technological advancements make it possible to build smart objects with great capabilities for sensing and connecting several possible advancements in ambient assisted living systems architectures. Indoor environments are characterized by several pollutant sources. Most of the monitoring frameworks instantly accessible are exceptionally costly and only permit the gathering of arbitrary examples. iAQ is an indoor air quality system based on an Internet of Things paradigm that incorporates in its construction Arduino, ESP8266, and XBee technologies for processing and data transmission and micro sensors for data acquisition. It also allows access to data collected through web access and through a mobile application in real time, and this data can be accessed by doctors in order to support medical diagnostics. Five smaller scale sensors of natural parameters (air temperature, moistness, carbon monoxide, carbon dioxide, and glow) were utilized. Different sensors can be included to check for particular contamination. The results reveal that the system can give a viable indoor air quality appraisal in order to anticipate technical interventions for improving indoor air quality. Indeed indoor air quality might be distinctively contrasted with what is normal for a quality living environment.
MacNeill, M; Kearney, J; Wallace, L; Gibson, M; Héroux, M E; Kuchta, J; Guernsey, J R; Wheeler, A J
2014-08-01
Indoor fine particles (FPs) are a combination of ambient particles that have infiltrated indoors, and particles that have been generated indoors from activities such as cooking. The objective of this paper was to estimate the infiltration factor (Finf ) and the ambient/non-ambient components of indoor FPs. To do this, continuous measurements were collected indoors and outdoors for seven consecutive days in 50 non-smoking homes in Halifax, Nova Scotia in both summer and winter using DustTrak (TSI Inc) photometers. Additionally, indoor and outdoor gravimetric measurements were made for each 24-h period in each home, using Harvard impactors (HI). A computerized algorithm was developed to remove (censor) peaks due to indoor sources. The censored indoor/outdoor ratio was then used to estimate daily Finfs and to determine the ambient and non-ambient components of total indoor concentrations. Finf estimates in Halifax (daily summer median = 0.80; daily winter median = 0.55) were higher than have been reported in other parts of Canada. In both winter and summer, the majority of FP was of ambient origin (daily winter median = 59%; daily summer median = 84%). Predictors of the non-ambient component included various cooking variables, combustion sources, relative humidity, and factors influencing ventilation. This work highlights the fact that regional factors can influence the contribution of ambient particles to indoor residential concentrations. Ambient and non-ambient particles have different risk management approaches, composition, and likely toxicity. Therefore, a better understanding of their contribution to the indoor environment is important to manage the health risks associated with fine particles (FPs) effectively. As well, a better understanding of the factors Finf can help improve exposure assessment and contribute to reduced exposure misclassification in epidemiologic studies. © 2013 Her Majesty the Queen in Right of Canada Indoor Air © 2013 John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.
Particle characterization in retail environments: concentrations, sources, and removal mechanisms.
Zaatari, M; Siegel, J
2014-08-01
Particles in retail environments can have consequences for the occupational exposures of retail workers and customers, as well as the energy costs associated with ventilation and filtration. Little is known about particle characteristics in retail environments. We measured indoor and outdoor mass concentrations of PM10 and PM2.5 , number concentrations of submicron particles (0.02-1 μm), size-resolved 0.3-10 μm particles, as well as ventilation rates in 14 retail stores during 24 site visits in Pennsylvania and Texas. Overall, the results were generally suggestive of relatively clean environments when compared to investigations of other building types and ambient/occupational regulatory limits. PM10 and PM2.5 concentrations (mean ± s.d.) were 20 ± 14 and 11 ± 10 μg/m(3), respectively, with indoor-to-outdoor ratios of 1.0 ± 0.7 and 0.88 ± 1.0. Mean submicron particle concentrations were 7220 ± 7500 particles/cm(3) with an indoor-to-outdoor ratio of 1.18 ± 1.30. The median contribution to PM10 and PM2.5 concentrations from indoor sources (vs. outdoors) was 83% and 53%, respectively. There were no significant correlations between measured ventilation rates and particle concentrations of any size. When examining options to lower PM2.5 concentrations below regulatory limits, the required changes to ventilation and filtration efficiency were site specific and depended on the indoor and outdoor concentration, emission rate, and infiltration level. Little is known about particle concentrations, contribution of indoor sources, and emission rates in retail environments. Knowledge of these particle characteristics informs health scientists with input parameters to include in exposure modeling. The predicted concentration change in response to different ventilation rates and filtration efficiencies may be used for guidance to develop control strategies to lower particulate matter concentrations in retail environments. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Request an environmental microbiologist. Her current research deals with screening indoor biocontaminutesants. She is responsible for the identification and characterization of mold, bacteria, and their metabolites in indoor environments.
Impact of Indoor Environment on Path Loss in Body Area Networks
Hausman, Sławomir; Januszkiewicz, Łukasz
2014-01-01
In this paper the influence of an example indoor environment on narrowband radio channel path loss for body area networks operating around 2.4 GHz is investigated using computer simulations and on-site measurements. In contrast to other similar studies, the simulation model included both a numerical human body phantom and its environment—room walls, floor and ceiling. As an example, radio signal attenuation between two different configurations of transceivers with dipole antennas placed in a direct vicinity of a human body (on-body scenario) is analyzed by computer simulations for several types of reflecting environments. In the analyzed case the propagation environments comprised a human body and office room walls. As a reference environment for comparison, free space with only a conducting ground plane, modelling a steel mesh reinforced concrete floor, was chosen. The transmitting and receiving antennas were placed in two on-body configurations chest–back and chest–arm. Path loss vs. frequency simulation results obtained using Finite Difference Time Domain (FDTD) method and a multi-tissue anthropomorphic phantom were compared to results of measurements taken with a vector network analyzer with a human subject located in an average-size empty cuboidal office room. A comparison of path loss values in different environments variants gives some qualitative and quantitative insight into the adequacy of simplified indoor environment model for the indoor body area network channel representation. PMID:25333289
Molds are multi-celled, colony forming, eukaryotic microorganisms lacking chlorophyll belonging to the Kingdom Fungi. Furthermore, molds are ubiquitous in both indoor and outdoor environments. There are more than 200 different types of fungi to which people are routinely exposed ...
Indoor Air Quality: A Guide for Educators.
ERIC Educational Resources Information Center
California State Dept. of Education, Sacramento.
Indoor air quality is a major concern for educators involved in the development of new school facilities, or the remodeling and maintenance of existing ones. This guide addresses the issue of air quality, the health concerns involved, and procedures for minimizing the impact of pollutants in the school environment. It defines common indoor air…
Emission models developed using small chamber data were combined with an Indoor Air Quality (IAQ) model to analyze the impact of volatile organic compound (VOC) emissions from latex paint on indoor environments. Test house experiments were conducted to verify the IAQ model's pred...
Environment and development of respiratory allergy. II. Indoors.
D'Amato, G; Liccardi, G; D'Amato, M
1994-12-01
Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.
Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances †
Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A.; Al-Khalifa, Hend S.
2016-01-01
In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space. PMID:27196906
Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances.
Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A; Al-Khalifa, Hend S
2016-05-16
In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.
NASA Astrophysics Data System (ADS)
Ogundele, Lasun T.; Olasinde, Roseline T.; Owoade, Oyediran K.; Olise, Felix S.
2018-05-01
This study presents the elemental compositions and concentrations of indoor dust and identifies the major sources in some selected indoor environments in Ile-Ife, Nigeria. The dust samples were collected from 16 indoor environments comprising offices, churches, residential and staff quarters using a cyclonic high power vacuum cleaner. The dust samples were analyzed for elemental concentrations using x-ray fluorescences. The data sets were analyzed for the possible sources and their contributions using Principal Component Factor Analysis (PCFA). The result showed that dust samples contained several elements: K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Ga, As, Rb, Sr, Se, Zr, V, and Sc. The PCFA identified three factors with the percentage variance of 92, 77, 71 and 68%, for the office, church, residential, and staff quarters, respectively, for the combined elemental data of each of the site classes. The identified sources were track-in-soil, road and windblown soil dust, paint debris, household dust from personal care materials, cooking, and cleaning activities. The unintentional track-in-soil due to mobility of the occupants, structural materials, and outdoor air was the major sources contributing to the indoor dust.
Hu, Jinhua; Li, Nianping; Lv, Yang; Liu, Jing; Xie, Jingchao; Zhang, Huibo
2017-01-01
Greater attention is currently being paid to the relationship between indoor environment and childhood allergies, however, the lack of reliable data and the disparity among different areas hinders reliable assessment of the relationship. This study focuses on the effect of indoor pollution on Chinese schoolchildren and the relationship between specific household and health problems suffered. The epidemiological questionnaire survey and the field measurement of the indoor thermal environment and primary air pollutants including CO2, fine particulate matter (PM2.5), chemical pollutants and fungi were performed in six Chinese cities. A total of 912 questionnaires were eligible for statistical analyses and sixty houses with schoolchildren aged 9–12 were selected for field investigation. Compared with Chinese national standards, inappropriate indoor relative humidity (<30% or >70%), CO2 concentration exceeding 1000 ppm and high PM2.5 levels were found in some monitored houses. Di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) were the most frequently detected semi-volatile organic compounds (SVOCs) in house dust. Cladosporium, Aspergillus and Penicillium were detected in both indoor air and house dust. This study indicates that a thermal environment with CO2 exceeding 1000 ppm, DEHP and DBP exceeding 1000 μg/g, and high level of PM2.5, Cladosporium, Aspergillus and Penicillium increases the risk of children’s allergies. PMID:28850091
Linardi, P M; Calheiros, C M L; Campelo-Junior, E B; Duarte, E M; Heukelbach, J; Feldmeier, H
2010-06-01
To explore the local transmission dynamics of Tunga penetrans in brazil, 134 soil samples from various environments were collected in three different endemic regions of the country and checked for the presence of the flea's larvae, pupae and adults. the samples, which came from an urban slum in the north-east, a village of xavante indians in the central-west and a community of yanomami indians living in traditional longhouses (malocas) in the north, were categorized as indoor, outdoor or indoor-outdoor (the latter representing samples collected in the malocas). The proportion of samples found positive for T. penetrans was lowest in the slum (9.3%) and highest in the Yanomami village (32.0%; P=0.01). Soil samples collected below bedsteads or hammocks or from the indoor resting places of dogs were significantly more likely to be positive than the indoor samples collected at other sites (65.0% v. 35.0%; P=0.02). There was no evidence indicating that the presence of T. penetrans in a soil sample was markedly affected by soil temperature, air temperature or air humidity. As no life stages of T. penetrans were found in any outdoor sample, it seems likely that, in resource-poor settings in Brazil, most transmission of T. penetrans occurs indoors. Control measures against the off-host life stages of T. penetrans should therefore be targeted at particular indoor micro-environments.
Hu, Jinhua; Li, Nianping; Lv, Yang; Liu, Jing; Xie, Jingchao; Zhang, Huibo
2017-08-29
Greater attention is currently being paid to the relationship between indoor environment and childhood allergies, however, the lack of reliable data and the disparity among different areas hinders reliable assessment of the relationship. This study focuses on the effect of indoor pollution on Chinese schoolchildren and the relationship between specific household and health problems suffered. The epidemiological questionnaire survey and the field measurement of the indoor thermal environment and primary air pollutants including CO₂, fine particulate matter (PM 2.5 ), chemical pollutants and fungi were performed in six Chinese cities. A total of 912 questionnaires were eligible for statistical analyses and sixty houses with schoolchildren aged 9-12 were selected for field investigation. Compared with Chinese national standards, inappropriate indoor relative humidity (<30% or >70%), CO₂ concentration exceeding 1000 ppm and high PM 2.5 levels were found in some monitored houses. Di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) were the most frequently detected semi-volatile organic compounds (SVOCs) in house dust. Cladosporium , Aspergillus and Penicillium were detected in both indoor air and house dust. This study indicates that a thermal environment with CO₂ exceeding 1000 ppm, DEHP and DBP exceeding 1000 μg/g, and high level of PM 2.5 , Cladosporium , Aspergillus and Penicillium increases the risk of children's allergies.
Van Loy, Michael D; Nazaroff, William W; Daisey, Joan M
1998-10-01
Recently developed models and data describing the interactions of gas-phase semi-volatile organic compounds with indoor surfaces are employed to examine the effects of sorption on nicotine's suitability as an environmental tobacco smoke (ETS) marker. Using parameters from our studies of nicotine sorption on carpet, painted wallboard, and stainless steel and previously published data on ETS particle deposition, the dynamic behavior of nicotine was modeled in two different indoor environments: a house and a stainless steel chamber. The results show that apparently contradictory observations of nicotine's behavior in indoor air can be understood by considering the effects of sorption under different experimental conditions. In indoor environments in which smoking has occurred regularly for an extended period, the sorbed mass of nicotine is very large relative to the mass emitted by a single cigarette. The importance of nicotine adsorption relative to ventilation as a gas-phase removal mechanism is reduced. Where smoking occurs less regularly or the indoor surfaces are cleaned prior to smoking (as in a laboratory chamber), nicotine deposition is more significant. Nicotine concentrations closely track the levels of other ETS constituents in environments with habitual smoking if the data are averaged over a period significantly longer than the period between cigarette combustion episodes. However, nicotine is not a suitable tracer for predicting ETS exposures at fine time scales or in settings where smoking occurs infrequently and irregularly.
Chen, Fei'er; Lin, Zhijing; Chen, Renjie; Norback, Dan; Liu, Cong; Kan, Haidong; Deng, Qihong; Huang, Chen; Hu, Yu; Zou, Zhijun; Liu, Wei; Wang, Juan; Lu, Chan; Qian, Hua; Yang, Xu; Zhang, Xin; Qu, Fang; Sundell, Jan; Zhang, Yinping; Li, Baizhan; Sun, Yuexia; Zhao, Zhuohui
2018-01-01
The urbanization and industrialization in China is accompanied by bad air quality, and the prevalence of asthma in Chinese children has been increasing in recent years. To investigate the associations between ambient PM 2.5 levels and asthmatic and allergic diseases or symptoms in preschool children in China, we assigned PM 2.5 exposure data from the Global Burden of Disease (GBD) project to 205 kindergartens at a spatial resolution of 0.1° × 0.1° in six cities in China (Shanghai, Nanjing, Chongqing, Changsha, Urumqi, and Taiyuan). A hierarchical multiple logistical regression model was applied to analyze the associations between kindergarten-level PM 2.5 exposure and individual-level outcomes of asthmatic and allergic symptoms. The individual-level variables, including gender, age, family history of asthma and allergic diseases, breastfeeding, parental smoking, indoor dampness, interior decoration pollution, household annual income, and city-level variable-annual temperature were adjusted. A total of 30,759 children (average age 4.6 years, 51.7% boys) were enrolled in this study. Apart from family history, indoor dampness, and decoration as predominant risk factors, we found that an increase of 10 μg/m 3 of the annual PM 2.5 was positively associated with the prevalence of allergic rhinitis by an odds ratio (OR) of 1.20 (95% confidence interval [CI] 1.11, 1.29) and diagnosed asthma by OR of 1.10 (95% CI 1.03, 1.18). Those who lived in non-urban (vs. urban) areas were exposed to more severe indoor air pollution arising from biomass combustion and had significantly higher ORs between PM 2.5 and allergic rhinitis and current rhinitis. Our study suggested that long-term exposure to PM 2.5 might increase the risks of asthmatic and allergic diseases or symptoms in preschool children in China. Compared to those living in urban areas, children living in suburban or rural areas had a higher risk of PM 2.5 exposure. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wei, Wenjuan; Mandin, Corinne; Ramalho, Olivier
2018-03-01
Semi-volatile organic compounds (SVOCs) in indoor environments can partition among the gas phase, airborne particles, settled dust, and available surfaces. The mass transfer parameters of SVOCs, such as the mass transfer coefficient and the partition coefficient, are influenced by indoor environmental factors. Subsequently, indoor SVOC concentrations and thus occupant exposure can vary depending on environmental factors. In this review, the influence of six environmental factors, i.e., indoor temperature, humidity, ventilation, airborne particle concentration, source loading factor, and reactive chemistry, on the mass transfer parameters and indoor concentrations of SVOCs was analyzed and tentatively quantified. The results show that all mass transfer parameters vary depending on environmental factors. These variations are mostly characterized by empirical equations, particularly for humidity. Theoretical calculations of these parameters based on mass transfer mechanisms are available only for the emission of SVOCs from source surfaces when airborne particles are not present. All mass transfer parameters depend on the temperature. Humidity influences the partition of SVOCs among different phases and is associated with phthalate hydrolysis. Ventilation has a combined effect with the airborne particle concentration on SVOC emission and their mass transfer among different phases. Indoor chemical reactions can produce or eliminate SVOCs slowly. To better model the dynamic SVOC concentration indoors, the present review suggests studying the combined effect of environmental factors in real indoor environments. Moreover, interactions between indoor environmental factors and human activities and their influence on SVOC mass transfer processes should be considered. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effectiveness and Predictability of Particle Damping
2000-01-01
Design Methodology for Extreme Environments,” Contract No. F33615-98-C-3005. The authors gratefully acknowledge the support and guidance of Mr. Robert...Mountain View, CA 94043 b University of Dayton Research Institute, 300 College Park, Dayton, OH 45469 ABSTRACT In this paper, recent results of...has been developed in support of this work. Keywords: Nonlinear, Particle, Granular, Impact, Damping 1. INTRODUCTION Particle damping is a derivative
Vimalanathan, Komalanathan; Ramesh Babu, Thangavelu
2014-01-01
The effect of indoor environment may have an influence on the performance, productivity health and well-being of office workers. Environmental factors such as indoor temperature and illumination have been investigated at three levels. A neurobehavioral test (NBT) has been proposed for the evaluation of office workersc performance. A field lab to emulate an office has been created. In controlled condition of environmental factors, the neurobehavioral test was conducted. The response time and the number of errors in each test have been recorded. A randomized block factorial design was used to analyze the responses of office worker's performance. The results revealed that the independent and interaction effect of temperature and illumination have significant effect on the office workers' performance. The effect of indoor room temperature has more influences than the effect of illumination. The effect of indoor temperature has 38.56% of contribution on the performance. The optimum levels of indoor temperature at 21°C and illumination at 1000 lux have improved the work performance and health of office workers. The indoor room temperature and illumination are more influence on the performance of the office workers. It may be concluded that the impact of indoor room temperature (38.56%) is more on the office worker's performance than the effect of illumination (19.91%). Further, it may be concluded that the optimum level of indoor room temperature (21°C) and illumination (1000lux) have improved the work performance, health and productivity of office workers.
[Enclosed environments and health].
Maroni, M; Barbieri, F
1989-01-01
Problems related to Indoor Air Quality are subject of study since about twenty years. New architectural criteria, new building materials and increasing demands of energy saving have progressively changed residences, offices and all non-industrial indoor environments. This paper present a review of the IAQ-related issues from sources characterization, to pollutant assessment and definition of effects on human health.
A limited-scale indoor air quality investigation was conducted over a 4 day period at the North Carolina Department of Environment, Health, and Natural Resources' offices located at 3800 Barrett Drive, Raleigh, NC. Integrated 9 hour particle, aldehyde, and volatile organic compou...
Thermal Analysis--Human Comfort--Indoor Environments. NBS Special Publication 491.
ERIC Educational Resources Information Center
Mangum, Billy W., Ed.; Hill, James E., Ed.
Included in these proceedings are 11 formal papers presented by leading researchers in the field of thermal comfort and heat stress at a symposium held for the purpose of exploring new aspects of indoor thermal environments, caused primarily by the impact of energy conservation in new and existing buildings. The contributed papers were from…
NASA Astrophysics Data System (ADS)
Murga, Alicia; Sano, Yusuke; Kawamoto, Yoichi; Ito, Kazuhide
2017-10-01
Mechanical and passive ventilation strategies directly impact indoor air quality. Passive ventilation has recently become widespread owing to its ability to reduce energy demand in buildings, such as the case of natural or cross ventilation. To understand the effect of natural ventilation on indoor environmental quality, outdoor-indoor flow paths need to be analyzed as functions of urban atmospheric conditions, topology of the built environment, and indoor conditions. Wind-driven natural ventilation (e.g., cross ventilation) can be calculated through the wind pressure coefficient distributions of outdoor wall surfaces and openings of a building, allowing the study of indoor air parameters and airborne contaminant concentrations. Variations in outside parameters will directly impact indoor air quality and residents' health. Numerical modeling can contribute to comprehend these various parameters because it allows full control of boundary conditions and sampling points. In this study, numerical weather prediction modeling was used to calculate wind profiles/distributions at the atmospheric scale, and computational fluid dynamics was used to model detailed urban and indoor flows, which were then integrated into a dynamic downscaling analysis to predict specific urban wind parameters from the atmospheric to built-environment scale. Wind velocity and contaminant concentration distributions inside a factory building were analyzed to assess the quality of the human working environment by using a computer simulated person. The impact of cross ventilation flows and its variations on local average contaminant concentration around a factory worker, and inhaled contaminant dose, were then discussed.
Sakellaris, Ioannis A; Saraga, Dikaia E; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G; Bluyssen, Philomena M
2016-04-25
Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.
Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.
2016-01-01
Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608
ERIC Educational Resources Information Center
Kennedy, Mike
2002-01-01
Reviews ways that schools can provide effective indoor learning environments by paying attention to the following areas: daylighting, acoustics, space allocation, technology implementation, ergonomics, maintenance, indoor air quality, safety, restrooms, and roofing. (GR)
NASA Astrophysics Data System (ADS)
Höppe, P.; Martinac, Ivo
In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ''sick building syndrome''.
Höppe, P; Martinac, I
1998-08-01
In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of "sick building syndrome".
Adapting Buildings for Indoor Air Quality in a Changing Climate
Climate change presents many challenges, including the production of severe weather events. These events and efforts to minimize their effects through weatherization can adversely affect indoor environments.
ASSESSING ALLERGENICITY OF INDOOR AIR FUNGAL CONTAMINANTS
Assessing Allergenicity of Indoor Air Fungal Contaminants
M D W Ward1, M E Viana2, N Haykal-Coates1, L B Copeland1, S H Gavett1, and MJ K Selgrade1. 1US EPA, ORD, NHEERL, RTP, NC, USA. 2NCSU, CVM, Raleigh, NC, USA.
Rationale: The indoor environment has increased in impor...
Indoor Air Quality: Tools for Schools Action Kit.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Indoor Air Div.
Good indoor air quality contributes to a favorable learning environment for students, productivity for teachers and staff, and a sense of comfort, health, and well-being for all school occupants. The goal of this kit is to provide clear and easily applied guidance that will help prevent Indoor Air Quality (IAQ) problems and resolve such problems…
Biodiversity and concentrations of airborne fungi in large US office buildings from the BASE study
NASA Astrophysics Data System (ADS)
Tsai, Feng C.; Macher, Janet M.; Hung, Yun-Yi
The Building Assessment Survey and Evaluation (BASE) study measured baseline concentrations of airborne fungi in 100 representative US office buildings in 1994-1998. Multiple samples for different sampling durations, sites, and times of the day were aggregated into building-wide indoor and outdoor average concentrations. Fungal concentrations were compared between locations (indoor vs. outdoor), sampling and analytical methods (culture vs. microscopy), and season (summer vs. winter). The arithmetic means (standard deviations) of the indoor/outdoor concentrations of culturable fungi and fungal spores were 100/680 (230/840) CFUm-3 and 270/6540 (1190/6780) sporem-3, respectively. Although fewer groups were observed indoors than outdoors, at lower average concentrations (except in two buildings), site-specific and building-wide indoor measurements had higher coefficients of variation. More groups were seen in summer, and aggregated concentrations tended to be higher than in winter except for culturable Aureobasidium spp. and Botrytis spp. outdoors and non-sporulating fungi in both locations. Rankings of the predominant fungi identified by both methods were similar, but overall indoor and outdoor spore concentrations were approximately 3 and 10 times higher, respectively, than concentrations of culturable fungi. In the 44 buildings with both measurements, the indoor and outdoor total culturable fungi to fungal spore ratios (total C/S ratios) were 1.27 and 0.25, with opposite seasonal patterns. The indoor C/S ratio was higher in summer than in winter (1.47 vs. 0.86; N=29 and 15, respectively), but the outdoor ratio was lower in summer (0.19 vs. 0.36, respectively). Comparison of the number of different fungal groups and individual occurrence in buildings and samples indicated that the outdoor environment and summer season were more diverse, but the proportional contributions of the groups were very similar suggesting that the indoor and outdoor environments were related as were summer and winter seasons for each location. The extreme (e.g., 90th percentile) indoor concentrations ( 200CFUm-3 and 210sporem-3) may provide reference values for non-complaint US office environments.
Detection of fluorotelomer alcohols in indoor environments and their relevance for human exposure.
Schlummer, Martin; Gruber, Ludwig; Fiedler, Dominik; Kizlauskas, Markus; Müller, Josef
2013-07-01
Fluorotelomer alcohols (FTOH) are important precursors of perfluorinated carboxylic acids (PFCA). These neutral and volatile compounds are frequently found in indoor air and may contribute to the overall human exposure to per- and polyfluorinated alkyl substances (PFAS). In this study air samples of ten workplace environments and a car interior were analysed. In addition, extracts and emissions from selected outdoor textiles were analysed in order to establish their potential contribution to the indoor levels of the above-mentioned compounds. Concentrations of FTOHs measured in air ranged from 0.15 to 46.8, 0.25 to 286, and 0.11 to 57.5ng/m(3) for 6:2, 8:2 and 10:2 FTOHs, respectively. The highest concentrations in air were identified in shops selling outdoor clothing, indicating outdoor textiles to be a relevant source of FTOH in indoor workplace environments. Total amounts of FTOH in materials of outdoor textiles accounted for <0.8-7.6, 12.1-180.9 and 4.65-105.7μg/dm(2) for 6:2, 8:2 and 10:2 FTOHs, respectively. Emission from selected textiles revealed emission rates of up to 494ng/h. The measured data show that a) FTOHs are present in indoor textiles (e.g. carpets), b) they are released at ambient temperatures and c) indoor air of shops selling outdoor textiles contains the highest levels of FTOH. Exposure of humans to perfluorooctanoic acid (PFOA) through absorption of FTOH and subsequent degradation is discussed on the basis of indoor air levels. Calculation of indoor air-related exposure using the median of the measured air levels revealed that exposure is on the same order of magnitude as the recently reported dietary intakes for a background-exposed population. On the basis of the 95th percentile, indoor air exposure to PFOA was estimated to exceed dietary exposure. However, indoor air-related intakes of FTOH are far below the tolerable daily intake (TDI) of PFOA, indicating that there is no risk to health, even when assuming an unrealistic complete degradation of FTOH into PFOA. Copyright © 2013 Elsevier Ltd. All rights reserved.
An Indoor Positioning Method for Smartphones Using Landmarks and PDR.
Wang, Xi; Jiang, Mingxing; Guo, Zhongwen; Hu, Naijun; Sun, Zhongwei; Liu, Jing
2016-12-15
Recently location based services (LBS) have become increasingly popular in indoor environments. Among these indoor positioning techniques providing LBS, a fusion approach combining WiFi-based and pedestrian dead reckoning (PDR) techniques is drawing more and more attention of researchers. Although this fusion method performs well in some cases, it still has some limitations, such as heavy computation and inconvenience for real-time use. In this work, we study map information of a given indoor environment, analyze variations of WiFi received signal strength (RSS), define several kinds of indoor landmarks, and then utilize these landmarks to correct accumulated errors derived from PDR. This fusion scheme, called Landmark-aided PDR (LaP), is proved to be light-weight and suitable for real-time implementation by running an Android application designed for the experiment. We compared LaP with other PDR-based fusion approaches. Experimental results show that the proposed scheme can achieve a significant improvement with an average accuracy of 2.17 m.
An Indoor Positioning Method for Smartphones Using Landmarks and PDR †
Wang, Xi; Jiang, Mingxing; Guo, Zhongwen; Hu, Naijun; Sun, Zhongwei; Liu, Jing
2016-01-01
Recently location based services (LBS) have become increasingly popular in indoor environments. Among these indoor positioning techniques providing LBS, a fusion approach combining WiFi-based and pedestrian dead reckoning (PDR) techniques is drawing more and more attention of researchers. Although this fusion method performs well in some cases, it still has some limitations, such as heavy computation and inconvenience for real-time use. In this work, we study map information of a given indoor environment, analyze variations of WiFi received signal strength (RSS), define several kinds of indoor landmarks, and then utilize these landmarks to correct accumulated errors derived from PDR. This fusion scheme, called Landmark-aided PDR (LaP), is proved to be light-weight and suitable for real-time implementation by running an Android application designed for the experiment. We compared LaP with other PDR-based fusion approaches. Experimental results show that the proposed scheme can achieve a significant improvement with an average accuracy of 2.17 m. PMID:27983670
Automatic Construction of Wi-Fi Radio Map Using Smartphones
NASA Astrophysics Data System (ADS)
Liu, Tao; Li, Qingquan; Zhang, Xing
2016-06-01
Indoor positioning could provide interesting services and applications. As one of the most popular indoor positioning methods, location fingerprinting determines the location of mobile users by matching the received signal strength (RSS) which is location dependent. However, fingerprinting-based indoor positioning requires calibration and updating of the fingerprints which is labor-intensive and time-consuming. In this paper, we propose a visual-based approach for the construction of radio map for anonymous indoor environments without any prior knowledge. This approach collects multi-sensors data, e.g. video, accelerometer, gyroscope, Wi-Fi signals, etc., when people (with smartphones) walks freely in indoor environments. Then, it uses the multi-sensor data to restore the trajectories of people based on an integrated structure from motion (SFM) and image matching method, and finally estimates location of sampling points on the trajectories and construct Wi-Fi radio map. Experiment results show that the average location error of the fingerprints is about 0.53 m.
Real-time indoor monitoring system based on wireless sensor networks
NASA Astrophysics Data System (ADS)
Wu, Zhengzhong; Liu, Zilin; Huang, Xiaowei; Liu, Jun
2008-10-01
Wireless sensor networks (WSN) greatly extend our ability to monitor and control the physical world. It can collaborate and aggregate a huge amount of sensed data to provide continuous and spatially dense observation of environment. The control and monitoring of indoor atmosphere conditions represents an important task with the aim of ensuring suitable working and living spaces to people. However, the comprehensive air quality, which includes monitoring of humidity, temperature, gas concentrations, etc., is not so easy to be monitored and controlled. In this paper an indoor WSN monitoring system was developed. In the system several sensors such as temperature sensor, humidity sensor, gases sensor, were built in a RF transceiver board for monitoring indoor environment conditions. The indoor environmental monitoring parameters can be transmitted by wireless to database server and then viewed throw PC or PDA accessed to the local area networks by administrators. The system, which was also field-tested and showed a reliable and robust characteristic, is significant and valuable to people.
A hybrid stochastic approach for self-location of wireless sensors in indoor environments.
Lloret, Jaime; Tomas, Jesus; Garcia, Miguel; Canovas, Alejandro
2009-01-01
Indoor location systems, especially those using wireless sensor networks, are used in many application areas. While the need for these systems is widely proven, there is a clear lack of accuracy. Many of the implemented applications have high errors in their location estimation because of the issues arising in the indoor environment. Two different approaches had been proposed using WLAN location systems: on the one hand, the so-called deductive methods take into account the physical properties of signal propagation. These systems require a propagation model, an environment map, and the position of the radio-stations. On the other hand, the so-called inductive methods require a previous training phase where the system learns the received signal strength (RSS) in each location. This phase can be very time consuming. This paper proposes a new stochastic approach which is based on a combination of deductive and inductive methods whereby wireless sensors could determine their positions using WLAN technology inside a floor of a building. Our goal is to reduce the training phase in an indoor environment, but, without an loss of precision. Finally, we compare the measurements taken using our proposed method in a real environment with the measurements taken by other developed systems. Comparisons between the proposed system and other hybrid methods are also provided.
A Hybrid Stochastic Approach for Self-Location of Wireless Sensors in Indoor Environments
Lloret, Jaime; Tomas, Jesus; Garcia, Miguel; Canovas, Alejandro
2009-01-01
Indoor location systems, especially those using wireless sensor networks, are used in many application areas. While the need for these systems is widely proven, there is a clear lack of accuracy. Many of the implemented applications have high errors in their location estimation because of the issues arising in the indoor environment. Two different approaches had been proposed using WLAN location systems: on the one hand, the so-called deductive methods take into account the physical properties of signal propagation. These systems require a propagation model, an environment map, and the position of the radio-stations. On the other hand, the so-called inductive methods require a previous training phase where the system learns the received signal strength (RSS) in each location. This phase can be very time consuming. This paper proposes a new stochastic approach which is based on a combination of deductive and inductive methods whereby wireless sensors could determine their positions using WLAN technology inside a floor of a building. Our goal is to reduce the training phase in an indoor environment, but, without an loss of precision. Finally, we compare the measurements taken using our proposed method in a real environment with the measurements taken by other developed systems. Comparisons between the proposed system and other hybrid methods are also provided. PMID:22412334
NASA Astrophysics Data System (ADS)
Moschandreas, D. J.; Vuilleumier, K. L.
Prior to this study, indoor air constituent levels and ventilation rates of hospitality environments had not been measured simultaneously. This investigation measured indoor Environmental Tobacco Smoke-related (ETS-related) constituent levels in two restaurants, a billiard hall and a casino. The objective of this study was to characterize ETS-related constituent levels inside hospitality environments when the ventilation rates satisfy the requirements of the ASHRAE 62-1989 Ventilation Standard. The ventilation rate of each selected hospitality environment was measured and adjusted. The study advanced only if the requirements of the ASHRAE 62-1989 Ventilation Standard - the pertinent standard of the American Society of Heating, Refrigeration and Air Conditioning Engineers - were satisfied. The supply rates of outdoor air and occupant density were measured intermittently to assure that the ventilation rate of each facility satisfied the standard under occupied conditions. Six ETS-related constituents were measured: respirable suspended particulate (RSP) matter, fluorescent particulate matter (FPM, an estimate of the ETS particle concentrations), ultraviolet particulate matter (UVPM, a second estimate of the ETS particle concentrations), solanesol, nicotine and 3-ethenylpyridine (3-EP). ETS-related constituent levels in smoking sections, non-smoking sections and outdoors were sampled daily for eight consecutive days at each hospitality environment. This study found that the difference between the concentrations of ETS-related constituents in indoor smoking and non-smoking sections was statistically significant. Differences between indoor non-smoking sections and outdoor ETS-related constituent levels were identified but were not statistically significant. Similarly, differences between weekday and weekend evenings were identified but were not statistically significant. The difference between indoor smoking sections and outdoors was statistically significant. Most importantly, ETS-related constituent concentrations measured indoors did not exceed existing occupational standards. It was concluded that if the measured ventilation rates of the sampled facilities satisfied the ASHRAE 62-1989 Ventilation Standard requirements, the corresponding ETS-related constituents were measured at concentrations below known harmful levels as specified by the American Conference of Governmental Industrial Hygiene (ACGIH).
Andrade, Alexandro; Dominski, Fábio Hech
2018-01-15
Systematic reviews have the potential to contribute substantially to environmental health and risk assessment. This study aimed to investigate indoor air quality of environments used for physical exercise and sports practice through a systematic review. The systematic review followed the PRISMA guidelines and was recorded in the PROSPERO registry (CRD42016036057). The search was performed using the SciELO, Science Direct, Scopus, LILACS, MEDLINE via PubMed, and SPORTDiscus databases, from their inception through April 2017. The search terms used in the databases were {air pollution" OR "air pollutants" OR "air quality"} AND {"physical exercise" OR "physical activity" OR "sport"}. The results of selected studies were divided into 5 categories for analysis: monitoring of air quality in the environment according to international guidelines, indoor-to-outdoor ratio (I/O), air quality during physical exercise, impact of air quality on health, and interventions to improve indoor air quality. Among 1281 studies screened, 34 satisfied the inclusion criteria. The monitoring of pollutants was conducted in 20 studies. CO and NO 2 were the most investigated pollutants, and guidelines were discussed in most studies. The I/O ratio was investigated in 12 studies, of which 9 showed a higher concentration of some pollutants in indoor rather than outdoor environments. Among the 34 studies selected, only 7 investigated the impact of indoor air pollution on human health. The population in most of these studies consisted of hockey players. Most studies conducted monitoring of pollutants in indoor environments used for physical exercise and sports practice. The earliest studies were conducted in ice skating rinks and the most recent evaluated gymnasiums, fitness centers, and sports centers. The CO, particulate matter, and NO 2 concentrations were the most investigated and have the longest history of investigation. These pollutants were within the limits established by guidelines in most studies. Studies that examined the association between air quality documented the adverse effects of pollution. There is a need for more studies focused on the relationship between pollution and health. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; ...
2015-03-02
The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less
Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; Gilbert, Jack A.; Stephens, Brent
2015-01-01
The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO2 concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×106 data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections. PMID:25729898
A Time-Aware Routing Map for Indoor Evacuation †
Zhao, Haifeng; Winter, Stephan
2016-01-01
Knowledge of dynamic environments expires over time. Thus, using static maps of the environment for decision making is problematic, especially in emergency situations, such as evacuations. This paper suggests a fading memory model for mapping dynamic environments: a mechanism to put less trust on older knowledge in decision making. The model has been assessed by simulating indoor evacuations, adopting and comparing various strategies in decision making. Results suggest that fading memory generally improves this decision making. PMID:26797610
Implementing Green Walls in Schools.
McCullough, Michael B; Martin, Michael D; Sajady, Mollika A
2018-01-01
Numerous studies in applied pedagogical design have shown that, at all educational levels, direct exposure to the natural environment can enhance learning by improving student attention and behaviors. Implementing green walls-a "vertical garden," or "living wall" interior wall that typically includes greenery, a growing medium (soil or substrate) and a water delivery system-provides environmental health benefits, but also provides a practical application within classrooms for minimizing directed attention fatigue in students by connecting them to "outdoor nature" within the indoor environment. Hands-on "project-based" learning is another pedagogical strategy that has proved to be effective across the spectrum of educational levels and across subject areas. Green walls have the potential to inspire critical thinking through a combination of project-based learning strategies and environmental education. The authors have outlined a curriculum involving the implementation of an indoor living wall system within a classroom-learning environment, incorporating project-based learning modules that interact with the wall. In conjunction with the passive health benefits of a green wall, project-based curriculum models can connect students interactively with indoor nature and have the potential to inspire real-world thinking related to science, technology, engineering, art, and mathematics fields within the indoor learning environment. Through a combination of these passive and interactive modes, students are connected to nature in the indoor environment regardless of weather conditions outdoors. Future research direction could include post-construction studies of the effectiveness of project-based curricula related to living walls, and the long-term impacts of implementing green walls in classrooms on school achievement and student behaviors.
Building characteristics affect the risk of allergy development.
Hesselmar, Bill; Aberg, Birgitta; Eriksson, Bo; Björkstén, Bengt; Aberg, Nils
2005-03-01
Damp dwellings increase the risk for house dust mite (HDM) infestation in temperate climate zones and may be associated with an increased risk for allergic disease. The aim of the study was to assess possible relationships between allergen levels in house dust, characteristics of residence buildings and allergic diseases in children. A subsample of 12-yr-old children, having the same address in 1991 and 1996, was selected from a population-based sample of children from the Göteborg area. Health inspectors examined the residences of all the 109 children and several different building characteristics including humidity and indoor temperature were collected. Dust samples for analysis of HDM allergens were collected from the children's beds, and for analysis of cat and dog allergens from the living room. Current health status was assessed by questionnaires, interviews and skin prick tests (SPT). Dog or cat allergens were found in all houses, even in houses without such animals. HDM allergens were found in 60% of the houses, but only six of them had levels exceeding 2 microg/g dust. There was a strong association between HDM-infestation and wheeze, but not with specific sensitization to HDM. The type of building (houses when compared with flats), the ventilation system and the presence of a basement had all major implications on respiratory symptoms, atopy and HDM infestation. We can conclude that dog or cat allergens were found in all houses, and a strong association between HDM infestation and indoor environment. Building construction affected both respiratory morbidity and sensitisation independently, suggesting not only worsening of symptoms but also a causative relationship with disease development. Copyright (c) 2005 Blackwell Munksgaard
Saito, Rena; Park, Ju-Hyeong; LeBouf, Ryan; Green, Brett J.; Park, Yeonmi
2017-01-01
Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/ MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically labeled verrucarol is available. PMID:26853932
Saito, Rena; Park, Ju-Hyeong; LeBouf, Ryan; Green, Brett J; Park, Yeonmi
2016-01-01
Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically labeled verrucarol is available.
Airborne fungi in low and high allergic prevalence child care centers
NASA Astrophysics Data System (ADS)
Zuraimi, M. S.; Fang, L.; Tan, T. K.; Chew, F. T.; Tham, K. W.
Fungi exposure has been linked to asthma and allergies among children. To determine the association between fungal exposure and wheeze and rhinitis symptoms, we examined concentrations of culturable indoor and outdoor fungi of various aerodynamic sizes in low and high allergic prevalence child care centers (CCCs) in Singapore. Environmental parameters were also performed for air temperature, relative humidity and ventilation rates, while information on CCC characteristics was collected via an inspection. Most commonly recovered fungi were Penicillium, Aspergillus, Geotrichum, Cladosporium and sterile mycelia with Geotrichum and sterile mycelia amounting to an average of 71.5% of the total airborne culturable fungi studied. Indoor and outdoor total culturable fungi concentrations and those in the size range of 1.1-3.3 μm were significantly higher in high allergic prevalence CCCs. When fungal types/genera were compared, indoor and outdoor Geotrichum and sterile mycelia of aerodynamic sizes 1.1-3.3 μm were found to be significantly elevated in high allergic prevalence CCCs. Indeed, average geometric mean diameters ( Dg, ave) of indoor and outdoor culturable fungi were consistently smaller in CCCs with high prevalence of allergies than those with low prevalence. We found significant associations of higher fungal concentrations, especially those with smaller aerodynamic sizes in CCCs situated near parks. There were no differences in fungal levels between CCCs with respect to their dampness profile mainly due to high CCC ventilation rates. Since particle size is a factor that determines where a fungi particle deposits in the respiratory tract, this study provides useful information in the etiology of wheeze and rhinitis symptoms among the CCC attending children.
The indoor-outdoor characteristics of water-soluble ion in PM2.5 in Tianjin wintertime.
Wang, Baoqing; Niu, Honghong; Liu, Bowei; Hu, Xinxin; Ren, Zihui
2018-05-15
The indoor and outdoor PM 2.5 mass concentration, water-soluble ion by filter sampler was analyzed on December 3-21, 2015 during wintertime in Tianjin, China. The results indicate that high humidity conditions result in the accumulation of atmospheric pollutants and reduce atmosphere visibility. The I/O ratio for PM 2.5 concentration in dormitory and lab are less than 1 in haze days. Indoor PM 2.5 concentration increases rapidly with outdoor PM 2.5 concentration increasing in haze days. The filtration factors of the dormitory and lab indicate nearly half of the outdoor PM 2.5 enters indoor environment. The human activities in dormitory could cause more the formation of PM 2.5 than those in lab. The concentration of SO 4 2- is the highest ion in water-soluble ion for outdoor PM 2.5 . The SO 4 2- , NO 3 - , NH 4 + , and Cl - are generated mainly by outdoor sources; however, the Na + , Ca 2+ , and Mg 2+ are generated mainly by indoor sources. The NH 4 NO 3 , (NH 4 ) 2 SO 4 , and NH 4 Cl accounts for 20.2~41.8%, 32.0~51.4%, and 6.4~10.6% of the total water-soluble ion in different indoor-outdoor environment. The total secondary aerosols including NH 4 NO 3 , (NH 4 ) 2 SO 4 , and NH 4 Cl in PM 2.5 are 28.3, 42.1, 28.2, 31.0, and 33.9% in outdoor environment for haze days, outdoor environment for non-haze days, dormitory for haze days, dormitory for non-haze days, and lab for haze days, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.
The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less
Abe, K
2012-06-01
Previously, the author proposed a 'fungal index' that quantifies the capacity for fungal growth in a test environment where a device (fungal detector) encapsulating spores of a xerophilic sensor fungus Eurotium herbariorum was placed. It was also found that an extremely xerophilic fungus, Aspergillus penicillioides, was suitable as a sensor fungus at sites with lower relative humidity (RH). In this report, the hydrophilic fungus Alternaria alternata was added to sensor fungi for the determination of the index in extremely humid environments. Measurements of the index and observations of the formation of spores by the sensor fungi were made in stable climates in moisture chambers, under natural conditions in homes, and in bathrooms prepared in an artificial climate chamber. Higher index values and earlier sporulation were obtained at higher RH in stable climates. The hydrophilic Alt. alternata showed the greatest response at 100% and 97.3% RH, the moderately xerophilic Eur. herbariorum, at 94%, 84%, and 75% RH, and the extremely xerophilic Asp. penicillioides, at 71% RH. In homes, the hydrophilic fungus was most active in water-usage areas, and the xerophilic fungi were most active in non-water-usage areas. Sporulation was observed on sensor fungi in fungal detectors placed in rooms where the index exceeded 18 ru/week after one-month exposure. Sites where the index exceeded 18 ru/week were referred to as damp, where fungal contamination seems to be unavoidable. Evaluations of ventilation systems in bathrooms with extremely humid climates showed typical examples of a countermeasure to fungal contamination. The purpose of this study is to establish a fungal index applicable in home environments with extremely high to relatively low relative humidity climates. The sensor fungus that showed the greatest response in a fungal detector (a device encapsulating spores of sensor fungi) served as not only a quantitative but also a qualitative indicator of the environment tested, indicating the type of fungi that would contaminate the site. A fungal index would be a good tool for detecting dampness that induces fungal contamination, which has adverse effects on human health. Evaluations of indoor climates would provide information useful to building owners, builders, designers, advisers, medical practitioners, and so on. Selection of the most suitable insulation systems in various buildings under different climates or evaluations of the drying process in water-damaged buildings could also be possible using fungal detectors and measurements of fungal indices. © 2011 John Wiley & Sons A/S.
Environmental Issues in Managing Asthma
Diette, Gregory B; McCormack, Meredith C; Hansel, Nadia N; Breysse, Patrick N; Matsui, Elizabeth C
2008-01-01
Management of asthma requires attention to environmental exposures both indoors and outdoors. Americans spend most of their time indoors, where they have a greater ability to modify their environment. The indoor environment contains both pollutants (eg, particulate matter, nitrogen dioxide, secondhand smoke, and ozone) and allergens from furred pets, dust mites, cockroaches, rodents, and molds. Indoor particulate matter consists of particles generated from indoor sources such as cooking and cleaning activities, and particles that penetrate from the outdoors. Nitrogen dioxide sources include gas stoves, furnaces, and fireplaces. Indoor particulate matter and nitrogen dioxide are linked to asthma morbidity. The indoor ozone concentration is mainly influenced by the outdoor ozone concentration. The health effects of indoor ozone exposure have not been well studied. In contrast, there is substantial evidence of detrimental health effects from secondhand smoke. Guideline recommendations are not specific for optimizing indoor air quality. The 2007 National Asthma Education and Prevention Program asthma guidelines recommend eliminating indoor smoking and improving the ventilation. Though the guidelines state that there is insufficient evidence to recommend air cleaners, air cleaners and reducing activities that generate indoor pollutants may be sound practical approaches for improving the health of individuals with asthma. The guidelines are more specific about allergen avoidance; they recommend identifying allergens to which the individual is immunoglobin E sensitized and employing a multifaceted, comprehensive strategy to reduce exposure. Outdoor air pollutants that impact asthma include particulate matter, ozone, nitrogen dioxide, and sulfur dioxide, and guidelines recommend that individuals with asthma avoid exertion outdoors when these pollutants are elevated. Outdoor allergens include tree, grass, and weed pollens, which vary in concentration by season. Recommendations to reduce exposure include staying indoors, keeping windows and doors closed, using air conditioning and perhaps high-efficiency particulate arrestor (HEPA) air filters, and thorough daily washing to remove allergens from one’s person. PMID:18426614
[Textural research on the origin and evolution of the"theory of drying dampness"and its initiator].
Zhou, X M; Hu, J P
2016-07-28
There are two different records, namely,"vulnerability to dampness in autumn"and"dryness prevailing"in autumn, in the Neijing ( Inner Canon ). In the Jin and Yuan Dynasties, Liu Wansu supplemented the pathogenesis of dryness pathogen, whereas Wang Andao explained the contradictory records in the Neijing . In the Qing Dynasty, Yu Chang definitely challenged the theory"vulnerability to dampness in autumn"of the Neijing ,triggering a debate on the recognition of"drying dampness". In fact, Yu Guopei was the initiator of"theory of drying dampness", who discussed the nature of Yin and Yang of"drying dampness"based on the laws of correspondence between human body and natural environment, elucidating that drying dampness should be the root of both exogenous disease and internal damage, and elaborating the etiology and pathogenesis of"drying dampness", the diagnosis and the nature of the drugs for drying dampness. Shi Shoutang inherited Yu's theory and made a further development. In modern times, some scholars advocated that"drying dampness"should be consideredalong with Yin and Yang, superficies and interior, excess and deficiency, cold and heat, as the guiding principle for syndrome differentiation.
Human Occupancy as a Source of Indoor Airborne Bacteria
Hospodsky, Denina; Qian, Jing; Nazaroff, William W.; Yamamoto, Naomichi; Bibby, Kyle; Rismani-Yazdi, Hamid; Peccia, Jordan
2012-01-01
Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM10 and PM2.5 size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM10. On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments. PMID:22529946
Moldy buildings, health of their occupants and fungal prevention.
Mihinova, D; Pieckova, E
2012-01-01
Microscopic fungi are important biological pollutants in the indoor environment, they are spread generally: on building materials, carpets, ceiling tiles, insulations, any surfaces, wallpapers, or in heating, ventilation, and air conditioning systems. Molds are able to grow on any materials, as long as moisture and oxygen are available. Exposure to fungi in indoor environments (esp. in water-damaged buildings) can cause adverse health effects, such as allergy, asthma, hypersensitivity pneumonia, mucous membrane irritation, different toxic effects, or even mycoses (in immunocompromised individuals) - alone or in combination. As serious adverse health effects could be caused antifungal prevention is an absolute need.This review article summarizes the occurrence of fungi in the indoor environment of buildings and their contribution to occupants´ health problems, and preventive measures against molds (Tab. 1, Fig. 1, Ref. 48).
Indoor Semi-volatile Organic Compounds (i-SVOC) Version 1.0
i-SVOC Version 1.0 is a general-purpose software application for dynamic modeling of the emission, transport, sorption, and distribution of semi-volatile organic compounds (SVOCs) in indoor environments.
75 FR 68784 - Healthy Indoor Environment Protocols for Home Energy Upgrades
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-09
... Home Energy Upgrades, in conjunction with the availability of the Department of Energy (DOE) Workforce... also provide the specific responses necessary to maintain or improve indoor air quality in conjunction...
Jiao, Yu; Yu, Hang; Wang, Tian; An, Yusong; Yu, Yifan
2017-12-01
The relationship between thermal environmental parameters and clothing insulation is an important element in improving thermal comfort for the elderly. A field study was conducted on the indoor, transition space, and outdoor thermal environments of 17 elderly facilities in Shanghai, China. A random questionnaire survey was used to gather data from 672 valid samples. A statistical analysis of the data was conducted, and multiple linear regression models were established to quantify the relationships between clothing insulation, respondent age, indoor air temperature, and indoor relative humidity. Results indicated that the average thermal insulation of winter and summer clothing is 1.38 clo and 0.44 clo, respectively, for elderly men and 1.39 clo and 0.45 clo, respectively, for elderly women. It was also found that the thermal insulation of winter clothing is linearly correlated with age, and that there were seasonal differences in the relationship between clothing insulation and the environment. During winter, the clothing insulation is negatively correlated only with indoor temperature parameters (air temperature and operative temperature) for elderly males, while it is negatively correlated with indoor temperature parameters as well as transition space and outdoor air temperature for elderly females. In summer, clothing insulation for both elderly males and females is negatively correlated with outdoor temperature, as well as indoor temperature parameters (air temperature and operative temperature). The thermal insulation of summer clothing is also negatively correlated with transitional space temperature for males. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chan, S.; Sohn, G.
2012-06-01
The past few years have seen wide spread adoption of outdoor positioning services, mainly GPS, being incorporated into everyday devices such as smartphones and tablets. While outdoor positioning has been well received by the public, its indoor counterpart has been mostly limited to private use due to its higher costs and complexity for setting up the proper environment. The objective of this research is to provide an affordable mean for indoor localization using wireless local area network (WLAN) Wi-Fi technology. We combined two different Wi-Fi approaches to locate a user. The first method involves the use of matching the pre-recorded received signal strength (RSS) from nearby access points (AP), to the data transmitted from the user on the fly. This is commonly known as "fingerprint matching". The second approach is a distance-based trilateration approach using three known AP coordinates detected on the user's device to derive the position. The combination of the two steps enhances the accuracy of the user position in an indoor environment allowing location-based services (LBS) such as mobile augmented reality (MAR) to be deployed more effectively in the indoor environment. The mapping of the RSS map can also prove useful to IT planning personnel for covering locations with no Wi-Fi coverage (ie. dead spots). The experiments presented in this research helps provide a foundation for the integration of indoor with outdoor positioning to create a seamless transition experience for users.
Light use efficiency for vegetables production in protected and indoor environments
NASA Astrophysics Data System (ADS)
Cocetta, Giacomo; Casciani, Daria; Bulgari, Roberta; Musante, Fulvio; Kołton, Anna; Rossi, Maurizio; Ferrante, Antonio
2017-01-01
In recent years, there is a growing interest for vegetables production in indoor or disadvantaged climatic zones by using greenhouses. The main problem of crop growing indoor or in environment with limited light availability is the correct choice of light source and the quality of lighting spectrum. In greenhouse and indoor cultivations, plant density is higher than in the open field and plants have to compete for light and nutrients. Nowadays, advanced systems for indoor horticulture use light emitting diodes (LED) for improving crop growth, enhancing the plant productivity and favouring the best nutritional quality formation. In closed environments, as indoor growing modules, the lighting system represents the only source of light and its features are fundamental for obtaining the best lighting performances for plant and the most efficient solution. LED lighting engines are more efficient compared to the lighting sources used traditionally in horticulture and allow light spectrum and intensity modulations to enhance the light use efficiency for plants. The lighting distribution and the digital controls are fundamental for tailoring the spectral distribution on each plant in specific moments of its growth and play an important role for optimizing growth and produce high-quality vegetables. LED lights can increase plant growth and yield, but also nutraceutical quality, since some light intensities increase pigments biosynthesis and enhance the antioxidants content of leaves or fruits: in this regards the selection of LED primary light sources in relation to the peaks of the absorbance curve of the plants is important.
Choo, Chua Poh; Jalaludin, Juliana
2015-01-01
The indoor environment is a major source of human exposure to pollutants. Some pollutants can have concentrations that are several times higher indoors than outdoors. Prolonged exposure may lead to adverse biologic effects, even at low concentrations. Several studies done in Malaysia had underlined the role of indoor air pollution in affecting respiratory health, especially for school-aged children. A critical review was conducted on the quantitative literature linking indoor air pollution with respiratory illnesses among school-aged children. This paper reviews evidence of the association between indoor air quality (IAQ) and its implications on respiratory health among Malaysian school-aged children. This review summarizes six relevant studies conducted in Malaysia for the past 10 years. Previous epidemiologic studies relevant to indoor air pollutants and their implications on school-aged children's respiratory health were obtained from electronic database and included as a reference in this review. The existing reviewed data emphasize the impact of IAQ parameters, namely, indoor temperature, ventilation rates, indoor concentration of carbon dioxide (CO2), carbon monoxide (CO), particulate matters (PM), volatile organic compounds (VOCs), nitrogen dioxide (NO2) and airborne microbes, on children's respiratory health. The study found that most of the Malaysian school-aged children are exposed to the inadequate environment during their times spent either in their houses or in their classrooms, which is not in compliance with the established standards. Children living in households or studying in schools in urban areas are more likely to suffer from respiratory illnesses compared with children living in homes or studying in schools in rural areas.
NASA Astrophysics Data System (ADS)
Edwards, Rufus D.; Jurvelin, J.; Koistinen, K.; Saarela, K.; Jantunen, M.
Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling.
The report discusses and presents data on constituents and emissions from products that have the potential to impact the indoor air environment. t is a tool to be used by researchers to help organize the study of materials as potential sources of indoor air emissions. ncluded are...
The Institute of Medicine of the NAS is conducting a study to evaluate the state of scientific understanding of the effects of climate change on indoor air quality and public health. General topics may include the likely impacts of climate change in the U.S. on the indoor environ...
Paradisi, R; Vanella, S; Barzanti, R; Cani, C; Battaglia, C; Seracchioli, R; Venturoli, S
2009-06-01
A number of studies indicated a clear decline in semen quality in the past 30-50 years and there is accumulating evidence that this decline might result from exposure to high levels of air pollution. To examine the impact of environment on male reproductive ability, we undertook for the first time a pilot study on semen quality of infertile men exposed to purification of indoor air. Ten subjects with a history of unexplained male infertility and poor semen quality were exposed for at least 1 year to a cleaning indoor air system (Koala technology). The key feature of this air purifier is the unique innovative multiple filtering system. The treatment of total purification of indoor air showed neither improvements in semen parameters nor variation in reproductive hormones (P = N.S.), but induced an evident increase (P < 0.03 and more) in seminal leucocytic concentrations. Within the limits due to the small sample of subjects recruited, the sole purification of indoor air does not seem enough to improve semen quality, although the increase in leucocytic concentrations could indicate an activation of the role of immunosurveillance in a purified indoor air environment.
Development of wireless sensor network for monitoring indoor air pollutant
NASA Astrophysics Data System (ADS)
Saad, Shaharil Mad; Shakaff, Ali Yeon Md; Saad, Abdul Rahman Mohd; Yusof @ Kamarudin, Azman Muhamad
2015-05-01
The air that we breathe with everyday contains variety of contaminants and particles. Some of these contaminants and particles are hazardous to human health. Most of the people don't realize that the content of air they being exposed to whether it was a good or bad air quality. The air quality whether in indoor or outdoor environment can be influenced by physical factors like dust particles, gaseous pollutants (including carbon dioxide, carbon monoxide and volatile organic compounds) and biological like molds and bacteria growth which largely depend on temperature and humidity condition of a room. These kinds of pollutants can affect human health, physical reaction, comfort or work performance. In this study, a wireless sensor network (WSN) monitoring system for monitor air pollutant in indoor environment was developed. The system was divided into three parts: web-based interface program, sensing module and a base station. The measured data was displayed on the web which is can be accessed by the user. The result shows that the overall measured parameters were meet the acceptable limit, requirement and criteria of indoor air pollution inside the building. The research can be used to improve the indoor air quality level in order to create a comfortable working and healthy environment for the occupants inside the building.
3D modeling of building indoor spaces and closed doors from imagery and point clouds.
Díaz-Vilariño, Lucía; Khoshelham, Kourosh; Martínez-Sánchez, Joaquín; Arias, Pedro
2015-02-03
3D models of indoor environments are increasingly gaining importance due to the wide range of applications to which they can be subjected: from redesign and visualization to monitoring and simulation. These models usually exist only for newly constructed buildings; therefore, the development of automatic approaches for reconstructing 3D indoors from imagery and/or point clouds can make the process easier, faster and cheaper. Among the constructive elements defining a building interior, doors are very common elements and their detection can be very useful either for knowing the environment structure, to perform an efficient navigation or to plan appropriate evacuation routes. The fact that doors are topologically connected to walls by being coplanar, together with the unavoidable presence of clutter and occlusions indoors, increases the inherent complexity of the automation of the recognition process. In this work, we present a pipeline of techniques used for the reconstruction and interpretation of building interiors based on point clouds and images. The methodology analyses the visibility problem of indoor environments and goes in depth with door candidate detection. The presented approach is tested in real data sets showing its potential with a high door detection rate and applicability for robust and efficient envelope reconstruction.
Rogerson, Mike; Gladwell, Valerie F.; Gallagher, Daniel J.; Barton, Jo L.
2016-01-01
This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future exercise intentions. PMID:27023580
Indirect health effects of relative humidity in indoor environments.
Arundel, A V; Sterling, E M; Biggin, J H; Sterling, T D
1986-01-01
A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versus low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens. PMID:3709462
Rogerson, Mike; Gladwell, Valerie F; Gallagher, Daniel J; Barton, Jo L
2016-03-25
This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future exercise intentions.
Peitzsch, Mirko; Sulyok, Michael; Täubel, Martin; Vishwanath, Vinay; Krop, Esmeralda; Borràs-Santos, Alicia; Hyvärinen, Anne; Nevalainen, Aino; Krska, Rudolf; Larsson, Lennart
2012-08-01
Secondary metabolites produced by fungi and bacteria are among the potential agents that contribute to adverse health effects observed in occupants of buildings affected by moisture damage, dampness and associated microbial growth. However, few attempts have been made to assess the occurrence of these compounds in relation to moisture damage and dampness in buildings. This study conducted in the context of the HITEA project (Health Effects of Indoor Pollutants: Integrating microbial, toxicological and epidemiological approaches) aimed at providing systematic information on the prevalence of microbial secondary metabolites in a large number of school buildings in three European countries, considering both buildings with and without moisture damage and/or dampness observations. In order to address the multitude and diversity of secondary metabolites a large number of more than 180 analytes was targeted in settled dust and surface swab samples using liquid chromatography/mass spectrometry (LC/MS) based methodology. While 42%, 58% and 44% of all samples collected in Spanish, Dutch and Finnish schools, respectively, were positive for at least one of the metabolites analyzed, frequency of detection for the individual microbial secondary metabolites - with the exceptions of emodin, certain enniatins and physcion - was low, typically in the range of and below 10% of positive samples. In total, 30 different fungal and bacterial secondary metabolites were found in the samples. Some differences in the metabolite profiles were observed between countries and between index and reference school buildings. A major finding in this study was that settled dust derived from moisture damaged, damp schools contained larger numbers of microbial secondary metabolites at higher levels compared to respective dust samples from schools not affected by moisture damage and dampness. This observation was true for schools in each of the three countries, but became statistically significant only when combining schools from all countries and thus increasing the sample number in the statistical analyses.
Bim-Based Indoor Path Planning Considering Obstacles
NASA Astrophysics Data System (ADS)
Xu, M.; Wei, S.; Zlatanova, S.; Zhang, R.
2017-09-01
At present, 87 % of people's activities are in indoor environment; indoor navigation has become a research issue. As the building structures for people's daily life are more and more complex, many obstacles influence humans' moving. Therefore it is essential to provide an accurate and efficient indoor path planning. Nowadays there are many challenges and problems in indoor navigation. Most existing path planning approaches are based on 2D plans, pay more attention to the geometric configuration of indoor space, often ignore rich semantic information of building components, and mostly consider simple indoor layout without taking into account the furniture. Addressing the above shortcomings, this paper uses BIM (IFC) as the input data and concentrates on indoor navigation considering obstacles in the multi-floor buildings. After geometric and semantic information are extracted, 2D and 3D space subdivision methods are adopted to build the indoor navigation network and to realize a path planning that avoids obstacles. The 3D space subdivision is based on triangular prism. The two approaches are verified by the experiments.
A Hybrid 3D Indoor Space Model
NASA Astrophysics Data System (ADS)
Jamali, Ali; Rahman, Alias Abdul; Boguslawski, Pawel
2016-10-01
GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM), Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.
Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings
NASA Astrophysics Data System (ADS)
Kraus, Michal
2017-10-01
Recent studies show that the relative humidity and the indoor air temperature constitute an important determinant of the quality of indoor air. Hygrothermal microclimate has a significant impact on occupant’s health and their comfort. The study presents the results of experimental measurement of indoor air temperature and relative humidity in selected apartment in prefabricated panel house situated in Ostrava, Czechia. The contribution describes and analysis the relation between indoor air temperature [°C] and relative humidity [%] in this apartment. The experimental object is selected with respect to the housing stock in the Czech Republic. A third of the housing stock in the Czech Republic is composed of prefabricated panel houses. Regeneration and revitalization of these buildings were in the focus of interest during recent years. Building modifications, such as thermal insulation of building envelope or window replacement, lead to a significantly higher level of airtightness of these objects. Humidity and indoor air temperature are measured in 10-minute cycles for two periods. The values of temperature and humidity are measured for the non-heating and the heating season. The length of each experimental period is 30 days. The mean value of indoor air temperature is 22.21 °C and average relative humidity is 45.87% in the non-heating period. The values of 22.62 °C and 35.20% represent average values for the heating period. A slight increase of the average temperature of the indoor environment (+1.85%) is observed. The decrease of the relative humidity is evident at first glance. The relative humidity of the internal environment is approximately 10% lower in the heating period. Long-term decline of relative humidity below 30% brings many problems. It is necessary to take measures to increase of relative humidity in residential prefabricated building. The aquarium appears to be ineffective. The solution may be forced artificial ventilation or humidifiers.
A model to estimate the cost effectiveness of the indoorenvironment improvements in office work
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seppanen, Olli; Fisk, William J.
2004-06-01
Deteriorated indoor climate is commonly related to increases in sick building syndrome symptoms, respiratory illnesses, sick leave, reduced comfort and losses in productivity. The cost of deteriorated indoor climate for the society is high. Some calculations show that the cost is higher than the heating energy costs of the same buildings. Also building-level calculations have shown that many measures taken to improve indoor air quality and climate are cost-effective when the potential monetary savings resulting from an improved indoor climate are included as benefits gained. As an initial step towards systemizing these building level calculations we have developed a conceptualmore » model to estimate the cost-effectiveness of various measures. The model shows the links between the improvements in the indoor environment and the following potential financial benefits: reduced medical care cost, reduced sick leave, better performance of work, lower turn over of employees, and lower cost of building maintenance due to fewer complaints about indoor air quality and climate. The pathways to these potential benefits from changes in building technology and practices go via several human responses to the indoor environment such as infectious diseases, allergies and asthma, sick building syndrome symptoms, perceived air quality, and thermal environment. The model also includes the annual cost of investments, operation costs, and cost savings of improved indoor climate. The conceptual model illustrates how various factors are linked to each other. SBS symptoms are probably the most commonly assessed health responses in IEQ studies and have been linked to several characteristics of buildings and IEQ. While the available evidence indicates that SBS symptoms can affect these outcomes and suspects that such a linkage exists, at present we can not quantify the relationships sufficiently for cost-benefit modeling. New research and analyses of existing data to quantify the financial importance of SBS symptoms would enable more widespread consideration of the effects of IEQ in cost benefit calculations.« less
Damping in aerospace composite materials
NASA Astrophysics Data System (ADS)
Agneni, A.; Balis Crema, L.; Castellani, A.
Experimental results are presented on specimens of carbon and Kevlar fibers in epoxy resin, materials used in many aerospace structures (control surfaces and wings in aircraft, large antennas in spacecraft, etc.). Some experimental methods of estimating damping ratios are first reviewed, either in the time domain or in the frequency domain. Some damping factor estimates from experimental tests are then shown; in order to evaluate the effects of the aerospace environment, damping factors have been obtained in a typical range of temperature, namely between +120 C and -120 C, and in the pressure range from room pressure to 10 exp -6 torr. Finally, a theoretical approach for predicting the bounds of the damping coefficients is shown, and prediction data are compared with experimental results.
ERIC Educational Resources Information Center
Kennedy, Mike
2003-01-01
Offers ten suggestions for schools and universities to help maintain a healthy indoor environment: proper flooring, sanitary washrooms, consistent maintenance, indoor air quality, preventing mold, daylighting, good acoustics, avoiding volatile organic compounds (VOCs), ergonomic furniture, and well-maintained roofs. (EV)
Indoor Air Pollution (Environmental Health Student Portal)
... on how indoor and outdoor air pollution affects human health. Healthy Air at Home (American Lung Association) - Resources ... and the environment, and the potential risks to human health. Experiments and Projects Air Quality (PDF, 981.40 ...
Space for Learning: A Pre-School Environment for Very Little Money.
ERIC Educational Resources Information Center
1972
This booklet identifies environments for pre-school learning. Each page may serve as a poster, a reminder of activities, or as a starting point for a training session. It includes an indoor and an outdoor section. The indoor section describes an art area, a music area, and a quiet area, a housekeeping area, free space for floor play, and a science…
Kamal, Atif; Cincinelli, Alessandra; Martellini, Tania; Palchetti, Ilaria; Bettazzi, Francesca; Malik, Riffat Naseem
2016-01-01
This study presents the analyses of urinary biomarkers (1-OHPyr, α- and β-naphthols) of polycyclic aromatic hydrocarbons (PAHs) exposure and biomarkers of effect (i.e. blood parameters) in petroleum-refinery workers (RFs) and auto-repair workers (MCs). Exposed subjects had higher concentrations of white blood cell (WBC) count than control subjects (CN) subjects (5.31 × 10(3) μL(-1) in exposed vs. 5.15 × 10(3) μL(-1) in CN subjects), while the biomarker of oxidative DNA damage (8-OHdG) was significantly higher in MCs. The exposure among these two cohorts could be influenced by the ambience of the workplaces; in fact, MCs' shops are relatively damp and enclosed workplaces in comparison with the indoor environment of refineries. PAHs in the dust samples from mechanical workshops probably originated from mixed sources (traffic exhaust and petroleum spills), while the incremental lifetime cancer risk (ILCR) for MCs showed moderate-to-low cancer risk from exposure to dust-bound PAHs. The study shows that increasing PAH exposure can be traced in MC workstations and needs to be investigated for the safety of public health.
Yang, Dan; Xu, Bin; Rao, Kaiyou; Sheng, Weihua
2018-01-24
Indoor occupants' positions are significant for smart home service systems, which usually consist of robot service(s), appliance control and other intelligent applications. In this paper, an innovative localization method is proposed for tracking humans' position in indoor environments based on passive infrared (PIR) sensors using an accessibility map and an A-star algorithm, aiming at providing intelligent services. First the accessibility map reflecting the visiting habits of the occupants is established through the integral training with indoor environments and other prior knowledge. Then the PIR sensors, which placement depends on the training results in the accessibility map, get the rough location information. For more precise positioning, the A-start algorithm is used to refine the localization, fused with the accessibility map and the PIR sensor data. Experiments were conducted in a mock apartment testbed. The ground truth data was obtained from an Opti-track system. The results demonstrate that the proposed method is able to track persons in a smart home environment and provide a solution for home robot localization.
Modelling of Indoor Environments Using Lindenmayer Systems
NASA Astrophysics Data System (ADS)
Peter, M.
2017-09-01
Documentation of the "as-built" state of building interiors has gained a lot of interest in the recent years. Various data acquisition methods exist, e.g. the extraction from photographed evacuation plans using image processing or, most prominently, indoor mobile laser scanning. Due to clutter or data gaps as well as errors during data acquisition and processing, automatic reconstruction of CAD/BIM-like models from these data sources is not a trivial task. Thus it is often tried to support reconstruction by general rules for the perpendicularity and parallelism which are predominant in man-made structures. Indoor environments of large, public buildings, however, often also follow higher-level rules like symmetry and repetition of e.g. room sizes and corridor widths. In the context of reconstruction of city city elements (e.g. street networks) or building elements (e.g. façade layouts), formal grammars have been put to use. In this paper, we describe the use of Lindenmayer systems - which originally have been developed for the computer-based modelling of plant growth - to model and reproduce the layout of indoor environments in 2D.
Yang, Dan; Xu, Bin; Rao, Kaiyou; Sheng, Weihua
2018-01-01
Indoor occupants’ positions are significant for smart home service systems, which usually consist of robot service(s), appliance control and other intelligent applications. In this paper, an innovative localization method is proposed for tracking humans’ position in indoor environments based on passive infrared (PIR) sensors using an accessibility map and an A-star algorithm, aiming at providing intelligent services. First the accessibility map reflecting the visiting habits of the occupants is established through the integral training with indoor environments and other prior knowledge. Then the PIR sensors, which placement depends on the training results in the accessibility map, get the rough location information. For more precise positioning, the A-start algorithm is used to refine the localization, fused with the accessibility map and the PIR sensor data. Experiments were conducted in a mock apartment testbed. The ground truth data was obtained from an Opti-track system. The results demonstrate that the proposed method is able to track persons in a smart home environment and provide a solution for home robot localization. PMID:29364188
Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals.
Liu, X; Zhai, Z
2007-12-01
Reduction in indoor environment quality calls for effective control and improvement measures. Accurate and prompt identification of contaminant sources ensures that they can be quickly removed and contaminated spaces isolated and cleaned. This paper discusses the use of inverse modeling to identify potential indoor pollutant sources with limited pollutant sensor data. The study reviews various inverse modeling methods for advection-dispersion problems and summarizes the methods into three major categories: forward, backward, and probability inverse modeling methods. The adjoint probability inverse modeling method is indicated as an appropriate model for indoor air pollutant tracking because it can quickly find source location, strength and release time without prior information. The paper introduces the principles of the adjoint probability method and establishes the corresponding adjoint equations for both multi-zone airflow models and computational fluid dynamics (CFD) models. The study proposes a two-stage inverse modeling approach integrating both multi-zone and CFD models, which can provide a rapid estimate of indoor pollution status and history for a whole building. Preliminary case study results indicate that the adjoint probability method is feasible for indoor pollutant inverse modeling. The proposed method can help identify contaminant source characteristics (location and release time) with limited sensor outputs. This will ensure an effective and prompt execution of building management strategies and thus achieve a healthy and safe indoor environment. The method can also help design optimal sensor networks.
Finell, E; Haverinen-Shaughnessy, U; Tolvanen, A; Laaksonen, S; Karvonen, S; Sund, R; Saaristo, V; Luopa, P; Ståhl, T; Putus, T; Pekkanen, J
2017-03-01
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building-related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools' observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools' psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school-related stress, poor teacher-student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = -0.43) and poor teacher-student relationship (standardized β = -0.22) were significant predictors of poor subjective IAQ. In addition, school-related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = -0.44). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dorizas, Paraskevi Vivian; Assimakopoulos, Margarita-Niki; Santamouris, Mattheos
2015-05-01
The perception of the indoor environmental quality (IEQ) through questionnaires in conjunction with in-field measurements related to the indoor air quality (IAQ), the thermal comfort and the lighting environment were studied in nine naturally ventilated schools of Athens, Greece. Cluster analysis was carried out in order to determine the ranges of indoor air pollutants, temperature (T), relative humidity (RH), and ventilation rates at which the students were satisfied with the indoor environment. It was found that increased levels of particulate matter did not have a negative effect on students' perception while students seemed to link the degradation of IAQ with temperature variations. Statistically significant correlations were further found between measurement results and students' perception of the IEQ. Students' sick building syndrome (SBS) symptoms and performance of schoolwork were also investigated as a function of the levels of indoor air pollutants and ventilation, and there were found significant positive correlations between particulate matter (PM) and certain health symptoms. Students' learning performance seemed to be affected by the ventilation rates and carbon dioxide (CO₂) concentrations while certain health effects positively correlated to the levels of PM and CO₂. The energy consumption of schools was rather low compared to other national findings, and both the electricity and oil consumption for heating positively correlated to the levels of indoor air pollutants.
The report discusses and presents data on constituents and emissions from products that have the potential to impact the indoor air environment. t is a tool to be used by researchers to help organize the study of materials as potential sources of indoor air emissions. ncluded are...
Since the 2001 U.S. federally mandated phase-out of residential uses of organophosphate (OP) insecticides, the use of and potential for human exposure to pyrethroid insecticides in the indoor residential environment increases, while that for OPs decreases. Here we report indoor ...
Physical activity patterns of ethnic children from low socio-economic environments within the UK.
Eyre, Emma Lisa Jane; Duncan, Michael Joseph; Birch, Samantha Louise; Cox, Valerie; Blackett, Matthew
2015-01-01
Many children fail to meet physical activity (PA) guidelines for health benefits. PA behaviours are complex and depend on numerous interrelated factors. The study aims to develop current understanding of how children from low Socio-economic environments within the UK use their surrounding built environments for PA by using advanced technology. The environment was assessed in 96 school children (7-9 years) using global positioning system (GPS) monitoring (Garmin Forerunner, 305). In a subsample of 46 children, the environment and PA were assessed using an integrated GPS and heart rate monitor. The percentage of time spent indoor, outdoor, in green and non-green environments along with time spent in moderate-to-vigorous PA (MVPA) in indoor and outdoor environments were assessed. A 2-by-2 repeated measures analysis of covariance, controlling for body mass index, BF%, assessed the environmental differences. The findings show that 42% of children from deprived wards of Coventry fail to meet PA guidelines, of which 43% was accumulated during school. Children engaged in more MVPA outdoor than indoor environments (P < 0.01) and a greater amount of time was spent in non-green environments (P < 0.01). Increased time outdoors was negatively associated with BF%. In conclusion, outdoor environments are important for health-enhancing PA and reducing fatness in deprived and ethnic children.
Residential indoor and personal PM10 exposures of ambient origin based on chemical components.
Xu, Jia; Bai, Zhipeng; You, Yan; Zhou, Jian; Zhang, Jiefeng; Niu, Can; Liu, Yating; Zhang, Nan; He, Fei; Ding, Xiao
2014-07-01
Many studies have focused on the relationships of particulate matter between indoor, outdoor and personal exposure; however, considerable uncertainties remain regarding the portion of indoor particles and personal exposure of ambient origin. As part of the Particle Exposure Assessment for Community Elderly (PEACE) study in Tianjin, China, we have further interpreted the relationships between personal, residential indoor, outdoor and community PM10 (particulate matter with aerodynamic diameters of less than 10 μm). Comparisons of the chemical compositions of PM10 samples were performed using the coefficient of divergence (COD). A robust regression method, least-trimmed squared (LTS) regression, was used to estimate the infiltration factors of PM10 from residential outdoor to indoor environments based on the particulate component concentrations. Personal exposures of ambient origin were also estimated. A relatively good correlation was found between the personal and indoor PM10 samples with respect to chemical composition. The infiltration factors (Finf) of the residential indoor-outdoor PM10 were 0.74±0.31 (mean±SD) in summer and 0.44±0.22 in winter, with medians of 0.98 and 0.48, respectively. The residential outdoor contributions to the indoor environments were 87±55 μg/m(3) in summer and 80±54 μg/m(3) in winter, with medians of 75 μg/m(3) and 61 μg/m(3), respectively. The personal exposures of ambient origin were 92±44 μg/m(3) in summer and 89±47 μg/m(3) in winter, with medians of 81 μg/m(3) and 80 μg/m(3), respectively. This study indicated that the infiltrations in an urbanized area in North China exhibited a seasonal difference: the residential outdoor contributions to residential indoor environments were larger in summer due to the higher use of natural ventilation. The personal exposures of ambient origin were comparable during the different seasons, whereas those of non-ambient origin were higher in summer than in winter.
Lim, J-M; Jeong, J-H; Lee, J-H; Moon, J-H; Chung, Y-S; Kim, K-H
2011-04-01
In this study, elemental composition of PM2.5 and the status of indoor/outdoor pollution were investigated in a commercial building near a roadside area in Daejeon, Korea. A total of 60 parallel PM2.5 samples were collected both on the roof (outdoor) and in an indoor office of a building near a highly congested road during the spring and fall of 2008. The concentrations of 23 elements were analysed from these PM2.5 samples using instrumental neutron activation analysis. PM2.5 levels in indoor environment (47.6 ± 16.5 μg/m(3)) were noticeably higher than the outdoor levels (37.7 ± 17.2 μg/m(3)) with the I/O concentration ratio of 1.37 ± 0.33 [correlation coefficient (r) = 0.89, P < 0.001]. Principal component analysis results coincidently showed the predominance of sources such as soil dust, traffic, oil/coal combustion and road dust for both indoor and outdoor microenvironments. An isolated source in the indoor environment was assigned to environmental tobacco smoke (ETS) with high factor loading of Ce, Cl, I, K, La and Zn. The overall results of our study indicate that the sources of indoor constituents were strongly dependent on outdoor processes except for the ones affected by independent sources such as ETS. An improved understanding of the factors affecting the indoor PM2.5 concentration levels can lead to the development of an efficient management strategy to control health risks from exposure to indoor PM2.5 and related toxic components. A comparison of our comprehensive data sets indicated that most indoor PM2.5 and associated elemental species were strongly enriched by indoor source activities along with infiltration of ambient outdoor air for a naturally ventilated building. © 2010 John Wiley & Sons A/S.
Acoustic vibrations of single suspended gold nanostructures
NASA Astrophysics Data System (ADS)
Major, Todd A.
The acoustic vibrations for single gold nanowires and gold plates were studied using time-resolved ultrafast transient absorption. The objective of this work was to remove the contribution of the supporting substrate from the damping of the acoustic vibrations of the metal nano-objects. This was achieved by suspending the nano-objects across trenches created by photolithography and reactive ion etching. Transient absorption measurements for single suspended gold nanowires were initially completed in air and water environments. The acoustic vibrations for gold nanowires over the trench in air last typically for several nanoseconds, whereas gold nanowires in water are damped more quickly. Continuum mechanics models suggest that the acoustic impedance mismatch between air and water dominates the damping rate. Later transient absorption studies on single suspended gold nanowires were completed in glycerol and ethylene glycol environments. However, our continuum mechanical model suggests nearly complete damping in glycerol due to its high viscosity, but similar damping rates are seen between the two liquids. The continuum mechanics model thus incorrectly addresses high viscosity effects on the lifetimes of the acoustic vibrations, and more complicated viscoelastic interactions occur for the higher viscosity liquids. (Abstract shortened by UMI.).
Shorter, Caroline; Crane, Julian; Pierse, Nevil; Barnes, Phillipa; Kang, Janice; Wickens, Kristin; Douwes, Jeroen; Stanley, Thorsten; Täubel, Martin; Hyvärinen, Anne; Howden-Chapman, Philippa
2018-01-01
Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case-control study involving 150 children with new-onset wheeze, aged between 1 and 7 years, each matched to two control children with no history of wheezing. Each participant's home was assessed for moisture damage, condensation, and mold growth by researchers, an independent building assessor and parents. Repeated measures of temperature and humidity were made, and electrostatic dust cloths were used to collect airborne microbes. Cloths were analyzed using qPCR. Children were skin prick tested for aeroallergens to establish atopy. Strong positive associations were found between observations of visible mold and new-onset wheezing in children (adjusted odds ratios ranged between 1.30 and 3.56; P ≤ .05). Visible mold and mold odor were consistently associated with new-onset wheezing in a dose-dependent manner. Measurements of qPCR microbial levels, temperature, and humidity were not associated with new-onset wheezing. The association between mold and new-onset wheeze was not modified by atopic status, suggesting a non-allergic association. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A Modular Localization System as a Positioning Service for Road Transport
Brida, Peter; Machaj, Juraj; Benikovsky, Jozef
2014-01-01
In recent times smart devices have attracted a large number of users. Since many of these devices allow position estimation using Global Navigation Satellite Systems (GNSS) signals, a large number of location-based applications and services have emerged, especially in transport systems. However GNSS signals are affected by the environment and are not always present, especially in dense urban environment or indoors. In this work firstly a Modular Localization Algorithm is proposed to allow seamless switching between different positioning modules. This helps us develop a positioning system that is able to provide position estimates in both indoor and outdoor environments without any user interaction. Since the proposed system can run as a service on any smart device, it could allow users to navigate not only in outdoor environments, but also indoors, e.g., underground garages, tunnels etc. Secondly we present the proposal of a 2-phase map reduction algorithm which allows one to significantly reduce the complexity of position estimation processes in case that positioning is performed using a fingerprinting framework. The proposed 2-phase map reduction algorithm can also improve the accuracy of the position estimates by filtering out reference points that are far from the mobile device. Both algorithms were implemented into a positioning system and tested in real world conditions in both indoor and outdoor environments. PMID:25353979
Assessment of zero-equation SGS models for simulating indoor environment
NASA Astrophysics Data System (ADS)
Taghinia, Javad; Rahman, Md Mizanur; Tse, Tim K. T.
2016-12-01
The understanding of air-flow in enclosed spaces plays a key role to designing ventilation systems and indoor environment. The computational fluid dynamics aspects dictate that the large eddy simulation (LES) offers a subtle means to analyze complex flows with recirculation and streamline curvature effects, providing more robust and accurate details than those of Reynolds-averaged Navier-Stokes simulations. This work assesses the performance of two zero-equation sub-grid scale models: the Rahman-Agarwal-Siikonen-Taghinia (RAST) model with a single grid-filter and the dynamic Smagorinsky model with grid-filter and test-filter scales. This in turn allows a cross-comparison of the effect of two different LES methods in simulating indoor air-flows with forced and mixed (natural + forced) convection. A better performance against experiments is indicated with the RAST model in wall-bounded non-equilibrium indoor air-flows; this is due to its sensitivity toward both the shear and vorticity parameters.
Indoor air quality of everyday use spaces dedicated to specific purposes-a review.
Marć, Mariusz; Śmiełowska, Monika; Namieśnik, Jacek; Zabiegała, Bożena
2018-01-01
According to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements, and individual garages. Some aspects of air quality in large-scale car parks, as a specific type of indoor environment, are also discussed. All those areas are characterized by relatively short time use. On the other hand, high and very high concentration levels of xenobiotics can be observed, resulting in higher exposure risk. The main compounds or group of chemical compounds are presented and discussed. The main factors influencing the type and amount of chemical pollutants present in the air of such areas are indicated.
Pohjoismäki, Jaakko L O; Karhunen, Pekka J; Goebeler, Sirkka; Saukko, Pekka; Sääksjärvi, Ilari E
2010-06-15
Fly species that are commonly recovered on human corpses concealed in houses or other dwellings are often dependent on human created environments and might have special features in their biology that allow them to colonize indoor cadavers. In this study we describe nine typical cases involving forensically relevant flies on human remains found indoors in southern Finland. Eggs, larvae and puparia were reared to adult stage and determined to species. Of the five species found the most common were Lucilia sericata Meigen, Calliphora vicina Robineau-Desvoidy and Protophormia terraenovae Robineau-Desvoidy. The flesh fly Sarcophaga caerulescens Zetterstedt is reported for the first time to colonize human cadavers inside houses and a COI gene sequence based DNA barcode is provided for it to help facilitate identification in the future. Fly biology, colonization speed and the significance of indoors forensic entomological evidence are discussed. (c) 2010 Elsevier Ireland Ltd. All rights reserved.
A salient region detection model combining background distribution measure for indoor robots.
Li, Na; Xu, Hui; Wang, Zhenhua; Sun, Lining; Chen, Guodong
2017-01-01
Vision system plays an important role in the field of indoor robot. Saliency detection methods, capturing regions that are perceived as important, are used to improve the performance of visual perception system. Most of state-of-the-art methods for saliency detection, performing outstandingly in natural images, cannot work in complicated indoor environment. Therefore, we propose a new method comprised of graph-based RGB-D segmentation, primary saliency measure, background distribution measure, and combination. Besides, region roundness is proposed to describe the compactness of a region to measure background distribution more robustly. To validate the proposed approach, eleven influential methods are compared on the DSD and ECSSD dataset. Moreover, we build a mobile robot platform for application in an actual environment, and design three different kinds of experimental constructions that are different viewpoints, illumination variations and partial occlusions. Experimental results demonstrate that our model outperforms existing methods and is useful for indoor mobile robots.
Duque Domingo, Jaime; Cerrada, Carlos; Valero, Enrique; Cerrada, Jose A
2017-10-20
This work presents an Indoor Positioning System to estimate the location of people navigating in complex indoor environments. The developed technique combines WiFi Positioning Systems and depth maps , delivering promising results in complex inhabited environments, consisting of various connected rooms, where people are freely moving. This is a non-intrusive system in which personal information about subjects is not needed and, although RGB-D cameras are installed in the sensing area, users are only required to carry their smart-phones. In this article, the methods developed to combine the above-mentioned technologies and the experiments performed to test the system are detailed. The obtained results show a significant improvement in terms of accuracy and performance with respect to previous WiFi-based solutions as well as an extension in the range of operation.
Structural Technology and Analysis Program (STAP) Delivery Order 0004: Durability Patch
NASA Astrophysics Data System (ADS)
Ikegami, Roy; Haugse, Eric; Trego, Angela; Rogers, Lynn; Maly, Joe
2001-06-01
Structural cracks in secondary structure, resulting from a high cycle fatigue (HCF) environment, are often referred to as nuisance cracks. This type of damage can result in costly inspections and repair. The repairs often do not last long because the repaired structure continues to respond in a resonant fashion to the environment. Although the use of materials for passive damping applications is well understood, there are few applications to high-cycle fatigue problems. This is because design information characterization temperature, resonant response frequency and strain levels are difficult to determine. The Durability Patch and Damage Dosimeter Program addressed these problems by: (1) Developing a damped repair design process which includes a methodology for designing the material and application characteristics required to optimally damp the repair. (2) Designing and developing a rugged, small, and lightweight data acquisition unit called the damage dosimeter. This is a battery operated, single board computer, capable of collecting three channels of strain and one channel of temperature, processing this data by user developed algorithms written in the C programming language, and storing the processed data in resident memory. The dosimeter is used to provide flight data needed to characterize the vibration environment. The vibration environment is then used to design the damping material characteristics and repair. The repair design methodology and dosimeter were demonstrated on B-52, C-130, and F-15 aircraft applications.
NASA Astrophysics Data System (ADS)
Wang, Xian-Ping; Zhang, Yi; Xia, Yu; Jiang, Wei-Bing; Liu, Hui; Liu, Wang; Gao, Yun-Xia; Zhang, Tao; Fang, Qian-Feng
2017-03-01
A novel micro-vibration sensitive-type high-damping Al matrix composites reinforced with Li7- x La3Zr2- x Nb x O12 (LLZNO, x = 0.25) was designed and prepared using an advanced spark plasma sintering (SPS) technique. The damping capacity and mechanical properties of LLZNO/Al composites (LLZNO content: 0-40 wt.%) were found to be greatly improved by the LLZNO addition. The maximum damping capacity and the ultimate tensile strength (UTS) of LLZNO/Al composite can be respectively up to 0.033 and 101.2 MPa in the case of 20 wt.% LLZNO addition. The enhancement of damping and mechanical properties of the composites was ascribed to the intrinsic high-damping capacity and strengthening effects of hard LLZNO particulate. This investigation provides a new insight to sensitively suppress micro-vibration of payloads in the aerospace environment.
Environmental tobacco smoke exposure assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guerin, M.R.
Environmental tobacco smoke (ETS) is the material released into the environment as tobacco products are smoked. Cigarettes, pipes, and cigars all produce ETS but the term has become all but synonymous with indoor air contamination by cigarette smoking. This is because cigarettes are by far the most commonly consumed tobacco product and because the principal human exposure occurs indoors. Exposure to ETS is variously termed as passive smoking, involuntary smoking, and as exposure to second-hand smoke. Considerable progress has been made toward a better understanding of ETS exposure. Strengths and limitations of various measures of exposure are better understood andmore » much data has been generated on the quantities of many ETS-constituents in many indoor environments. The properties of ETS, methods for its measurement in indoor air, and many results of field studies have recently been reviewed by the author. The recent EPA report includes a major treatment of exposure estimation including air concentrations, questionnaires, and biomarkers. This paper discusses approaches to exposure assessment and summarizes data on indoor air concentrations of ETS-constituents.« less
Chamber Bioaerosol Study: Outdoor Air and Human Occupants as Sources of Indoor Airborne Microbes
Adams, Rachel I.; Bhangar, Seema; Pasut, Wilmer; Arens, Edward A.; Taylor, John W.; Lindow, Steven E.; Nazaroff, William W.; Bruns, Thomas D.
2015-01-01
Human occupants are an important source of microbes in indoor environments. In this study, we used DNA sequencing of filter samples to assess the fungal and bacterial composition of air in an environmental chamber under different levels of occupancy, activity, and exposed or covered carpeting. In this office-like, mechanically ventilated environment, results showed a strong influence of outdoor-derived particles, with the indoor microbial composition tracking that of outdoor air for the 2-hour sampling periods. The number of occupants and their activity played a significant but smaller role influencing the composition of indoor bioaerosols. Human-associated taxa were observed but were not particularly abundant, except in the case of one fungus that appeared to be transported into the chamber on the clothing of a study participant. Overall, this study revealed a smaller signature of human body-associated taxa than had been expected based on recent studies of indoor microbiomes, suggesting that occupants may not exert a strong influence on bioaerosol microbial composition in a space that, like many offices, is well ventilated with air that is moderately filtered and moderately occupied. PMID:26024222
Liu, Ting; Li, Lu; Zhang, Jia-quan; Zhan, Chang-lin; Liu, Hong-xia; Zheng, Jing-ru; Yao, Rui-zhen; Cao, Jun-ji
2016-04-15
Bioaerosols of university dormitory can spread through air and cause a potential health risk for student staying in indoor environment. To quantify the characteristics of bioaerosols in indoor environment of university dormitory, concentration and size distribution of culturable bioaerosols were detected during the plum rain period, the correlations of culturable bioaerosol with concentration of particulate matter, the ambient temperature and relative humidity were analyzed using Spearman's correlation coefficient and finally the changes of size distribution of culturable bioaerosol caused by activities of students were detected. The results showed that the mean concentrations of culturable airborne bacteria and fungi were (2133 +/- 1617) CFUm' and (3111 +/- 2202) CFU x m(-3). The concentrations of culturable airborne bacteria and fungi exhibited negative correlation with PM1, PM2.5, and PM10, respectively. The respirable fractions of bacteria exhibited positive correlation with PM2.5, and the respirable fractions of fungi exhibited significant positive correlation with PM10. Ambient temperature had positive correlation with culturable airborne bacteria and fungi, and relative humidity had negative correlation with culturable airborne bacteria and fungi. In the afternoon, concentrations of culturable airborne fungi in indoor environment of university dormitory significantly increased, and the size distribution of culturable hioaerosols was different in the morning and afternoon.
Practical Implementation of Semi-Automated As-Built Bim Creation for Complex Indoor Environments
NASA Astrophysics Data System (ADS)
Yoon, S.; Jung, J.; Heo, J.
2015-05-01
In recent days, for efficient management and operation of existing buildings, the importance of as-built BIM is emphasized in AEC/FM domain. However, fully automated as-built BIM creation is a tough issue since newly-constructed buildings are becoming more complex. To manage this problem, our research group has developed a semi-automated approach, focusing on productive 3D as-built BIM creation for complex indoor environments. In order to test its feasibility for a variety of complex indoor environments, we applied the developed approach to model the `Charlotte stairs' in Lotte World Mall, Korea. The approach includes 4 main phases: data acquisition, data pre-processing, geometric drawing, and as-built BIM creation. In the data acquisition phase, due to its complex structure, we moved the scanner location several times to obtain the entire point clouds of the test site. After which, data pre-processing phase entailing point-cloud registration, noise removal, and coordinate transformation was followed. The 3D geometric drawing was created using the RANSAC-based plane detection and boundary tracing methods. Finally, in order to create a semantically-rich BIM, the geometric drawing was imported into the commercial BIM software. The final as-built BIM confirmed that the feasibility of the proposed approach in the complex indoor environment.
Indoor Allergens and Allergic Respiratory Disease
Chapman, Martin D.; Wünschmann, Sabina
2016-01-01
Purpose of review The purpose of this review is to evaluate the most recent findings on indoor allergens and their impact on allergic diseases. Recent findings Indoor allergens are present inside buildings (home, work environment, school), and given the chronic nature of the exposures, indoor allergies tend to be associated with the development of asthma. The most common indoor allergens are derived from dust mites, cockroaches, mammals (including wild rodents and pets), and fungi. The advent of molecular biology and proteomics has led to the identification, cloning, and expression of new indoor allergens, which have facilitated research to elucidate their role in allergic diseases. This review is an update on new allergens and their molecular features, together with the most recent reports on their avoidance for allergy prevention and their use for diagnosis and treatment. Summary Research progress on indoor allergens will result in the development of new diagnostic tools and design of coherent strategies for immunotherapy. PMID:27184001
Fekadu, Samuel; Getachewu, Bahilu
2015-04-01
Hospital environment represents a congenial situation where microorganisms and susceptible patients are indoors together. Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of seven wards of Jimma University Specialized Hospital was determined. Passive air sampling technique, using open Petri-dishes containing different culture media, was employed to collect sample twice daily. The concentrations of bacteria and fungi aerosols in the indoor environment of the wards ranged between 2123 - 9733 CFU/m(3). The statistical analysis showed that the concentrations of bacteria that were measured in all studied wards were significantly different from each other (p-value=0.017), whereas the concentrations of fungi that were measured in all sampled wards were not significantly different from each other (p-value=0.850). Moreover, the concentrations of bacteria that were measured at different sampling time (morning and afternoon) were significantly different (p-value =0.001). All wards that were included in the study were heavily contaminated with bacteria and fungi. Thus, immediate interventions are needed to control those environmental factors which favor the growth and multiplication of microbes, and it is vital to control visitors and students in and out the wards. Moreover, it is advisable that strict measures be put in place to check the increasing microbial load in the hospital environment.
NASA Astrophysics Data System (ADS)
Quinn, Ashlinn; Shaman, Jeffrey
2017-07-01
Little monitoring has been conducted of temperature and humidity inside homes despite the fact that these conditions may be relevant to health outcomes. Previous studies have observed associations between self-reported perceptions of the indoor environment and health. Here, we investigate associations between measured temperature and humidity, perceptions of indoor environmental conditions, and health symptoms in a sample of New York City apartments. We measured temperature and humidity in 40 New York City apartments during summer and winter seasons and collected survey data from the households' residents. Health outcomes of interest were (1) sleep quality, (2) symptoms of heat illness (summer season), and (3) symptoms of respiratory viral infection (winter season). Using mixed-effects logistic regression models, we investigated associations between the perceptions, symptoms, and measured conditions in each season. Perceptions of indoor temperature were significantly associated with measured temperature in both the summer and the winter, with a stronger association in the summer season. Sleep quality was inversely related to measured and perceived indoor temperature in the summer season only. Heat illness symptoms were associated with perceived, but not measured, temperature in the summer season. We did not find an association between any measured or perceived condition and cases of respiratory infection in the winter season. Although limited in size, the results of this study reveal that indoor temperature may impact sleep quality, and that thermal perceptions of the indoor environment may indicate vulnerability to heat illness. These are both important avenues for further investigation.
The Isprs Benchmark on Indoor Modelling
NASA Astrophysics Data System (ADS)
Khoshelham, K.; Díaz Vilariño, L.; Peter, M.; Kang, Z.; Acharya, D.
2017-09-01
Automated generation of 3D indoor models from point cloud data has been a topic of intensive research in recent years. While results on various datasets have been reported in literature, a comparison of the performance of different methods has not been possible due to the lack of benchmark datasets and a common evaluation framework. The ISPRS benchmark on indoor modelling aims to address this issue by providing a public benchmark dataset and an evaluation framework for performance comparison of indoor modelling methods. In this paper, we present the benchmark dataset comprising several point clouds of indoor environments captured by different sensors. We also discuss the evaluation and comparison of indoor modelling methods based on manually created reference models and appropriate quality evaluation criteria. The benchmark dataset is available for download at: http://www2.isprs.org/commissions/comm4/wg5/benchmark-on-indoor-modelling.html.
Smartphone-based integrated PDR/GPS/Bluetooth pedestrian location
NASA Astrophysics Data System (ADS)
Li, Xianghong; Wei, Dongyan; Lai, Qifeng; Xu, Ying; Yuan, Hong
2017-02-01
Typical indoor location method is fingerprint and traditional outdoor location system is GPS. Both of them are of poor accuracy and limited only for indoor or outdoor environments. As the smartphones are equipped with MEMS sensors, it means PDR can be widely used. In this paper, an algorithm of smartphone-based integrated PDR/GPS/Bluetooth for pedestrian location in the indoor/outdoor is proposed, which can be highly expected to realize seamless indoor/outdoor localization of the pedestrian. In addition, we also provide technologies to estimate orientation with Magnetometer and Gyroscope and detect context with output of sensors. The extensive experimental results show that the proposed algorithm can realize seamless indoor/outdoor localization.
Children exposure to indoor ultrafine particles in urban and rural school environments.
Cavaleiro Rufo, João; Madureira, Joana; Paciência, Inês; Slezakova, Klara; Pereira, Maria do Carmo; Aguiar, Lívia; Teixeira, João Paulo; Moreira, André; Oliveira Fernandes, Eduardo
2016-07-01
Extended exposure to ultrafine particles (UFPs) may lead to consequences in children due to their increased susceptibility when compared to older individuals. Since children spend in average 8 h/day in primary schools, assessing the number concentrations of UFPs in these institutions is important in order to evaluate the health risk for children in primary schools caused by indoor air pollution. Thus, the purpose of this study was to assess and determine the sources of indoor UFP number concentrations in urban and rural Portuguese primary schools. Indoor and outdoor ultrafine particle (UFP) number concentrations were measured in six urban schools (US) and two rural schools (RS) located in the north of Portugal, during the heating season. The mean number concentrations of indoor UFPs were significantly higher in urban schools than in rural ones (10.4 × 10(3) and 5.7 × 10(3) pt/cm(3), respectively). Higher UFP levels were associated with higher squared meters per student, floor levels closer to the ground, chalk boards, furniture or floor covering materials made of wood and windows with double-glazing. Indoor number concentrations of ultrafine-particles were inversely correlated with indoor CO2 levels. In the present work, indoor and outdoor concentrations of UFPs in public primary schools located in urban and rural areas were assessed, and the main sources were identified for each environment. The results not only showed that UFP pollution is present in augmented concentrations in US when compared to RS but also revealed some classroom/school characteristics that influence the concentrations of UFPs in primary schools.
A Visual-Based Approach for Indoor Radio Map Construction Using Smartphones.
Liu, Tao; Zhang, Xing; Li, Qingquan; Fang, Zhixiang
2017-08-04
Localization of users in indoor spaces is a common issue in many applications. Among various technologies, a Wi-Fi fingerprinting based localization solution has attracted much attention, since it can be easily deployed using the existing off-the-shelf mobile devices and wireless networks. However, the collection of the Wi-Fi radio map is quite labor-intensive, which limits its potential for large-scale application. In this paper, a visual-based approach is proposed for the construction of a radio map in anonymous indoor environments. This approach collects multi-sensor data, e.g., Wi-Fi signals, video frames, inertial readings, when people are walking in indoor environments with smartphones in their hands. Then, it spatially recovers the trajectories of people by using both visual and inertial information. Finally, it estimates the location of fingerprints from the trajectories and constructs a Wi-Fi radio map. Experiment results show that the average location error of the fingerprints is about 0.53 m. A weighted k-nearest neighbor method is also used to evaluate the constructed radio map. The average localization error is about 3.2 m, indicating that the quality of the constructed radio map is at the same level as those constructed by site surveying. However, this approach can greatly reduce the human labor cost, which increases the potential for applying it to large indoor environments.
Characterizing the bacterial communities in retail stores in the United States.
Hoisington, A; Maestre, J P; Kinney, K A; Siegel, J A
2016-12-01
The microorganisms present in retail environments have not been studied in detail despite the fact that these environments represent a potentially important location for exposure. In this study, HVAC filter dust samples in 13 US retail stores were collected and analyzed via pyrosequencing to characterize the indoor bacterial communities and to explore potential relationships between these communities and building and environmental parameters. Although retail stores contained a diverse bacterial community of 788 unique genera, over half of the nearly 118K sequences were attributed to the Proteobacteria phylum. Streptophyta, Bacillus, Corynebacterium, Pseudomonas, and Acinetobacter were the most prevalent genera detected. The recovered indoor airborne microbial community was statistically associated with both human oral and skin microbiota, indicating occupants are important contributors, despite a relatively low occupant density per unit volume in retail stores. Bacteria generally associated with outdoor environments were present in the indoor communities with no obvious association with air exchange rate, even when considering relative abundance. No significant association was observed between the indoor bacterial community recovered and store location, store type, or season. However, predictive functional gene profiling showed significant associations between the indoor community and season. The microbiome recovered from multiple samples collected months apart from the same building varied significantly indicating that caution is warranted when trying to characterize the bacterial community with a single sampling event. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zou, Han; Lu, Xiaoxuan; Jiang, Hao; Xie, Lihua
2015-01-15
Nowadays, developing indoor positioning systems (IPSs) has become an attractive research topic due to the increasing demands on location-based service (LBS) in indoor environments. WiFi technology has been studied and explored to provide indoor positioning service for years in view of the wide deployment and availability of existing WiFi infrastructures in indoor environments. A large body of WiFi-based IPSs adopt fingerprinting approaches for localization. However, these IPSs suffer from two major problems: the intensive costs of manpower and time for offline site survey and the inflexibility to environmental dynamics. In this paper, we propose an indoor localization algorithm based on an online sequential extreme learning machine (OS-ELM) to address the above problems accordingly. The fast learning speed of OS-ELM can reduce the time and manpower costs for the offline site survey. Meanwhile, its online sequential learning ability enables the proposed localization algorithm to adapt in a timely manner to environmental dynamics. Experiments under specific environmental changes, such as variations of occupancy distribution and events of opening or closing of doors, are conducted to evaluate the performance of OS-ELM. The simulation and experimental results show that the proposed localization algorithm can provide higher localization accuracy than traditional approaches, due to its fast adaptation to various environmental dynamics.
Development of indoor environmental index: Air quality index and thermal comfort index
NASA Astrophysics Data System (ADS)
Saad, S. M.; Shakaff, A. Y. M.; Saad, A. R. M.; Yusof, A. M.; Andrew, A. M.; Zakaria, A.; Adom, A. H.
2017-03-01
In this paper, index for indoor air quality (also known as IAQI) and thermal comfort index (TCI) have been developed. The IAQI was actually modified from previous outdoor air quality index (AQI) designed by the United States Environmental Protection Agency (US EPA). In order to measure the index, a real-time monitoring system to monitor indoor air quality level was developed. The proposed system consists of three parts: sensor module cloud, base station and service-oriented client. The sensor module cloud (SMC) contains collections of sensor modules that measures the air quality data and transmit the captured data to base station through wireless. Each sensor modules includes an integrated sensor array that can measure indoor air parameters like Carbon Dioxide, Carbon Monoxide, Ozone, Nitrogen Dioxide, Oxygen, Volatile Organic Compound and Particulate Matter. Temperature and humidity were also being measured in order to determine comfort condition in indoor environment. The result from several experiments show that the system is able to measure the air quality presented in IAQI and TCI in many indoor environment settings like air-conditioner, chemical present and cigarette smoke that may impact the air quality. It also shows that the air quality are changing dramatically, thus real-time monitoring system is essential.
Analyzing symptom data in indoor air questionnaires for primary schools.
Ung-Lanki, S; Lampi, J; Pekkanen, J
2017-09-01
Questionnaires on symptoms and perceived quality of indoor environment are used to assess indoor environment problems, but mainly among adults. The aim of this article was to explore best ways to analyze and report such symptom data, as part of a project to develop a parent-administered indoor air questionnaire for primary school pupils. Indoor air questionnaire with 25 questions on child's symptoms in the last 4 weeks was sent to parents in five primary schools with indoor air problems and in five control schools. About 83% of parents (N=1470) in case schools and 82% (N=805) in control schools returned the questionnaire. In two schools, 351 (52%) parents answered the questionnaire twice with a 2-week interval. Based on prevalence of symptoms, their test-retest repeatability (ICC), and on principal component analysis (PCA), the number of symptoms was reduced to 17 and six symptoms scores were developed. Six variants of these six symptom scores were then formed and their ability to rank schools compared. Four symptom scores (respiratory, lower respiratory, eye, and general symptoms) analyzed dichotomized maintained sufficiently well the diversity of symptom data and captured the between-school differences in symptom prevalence, when compared to more complex and numerous scores. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Oh, TaeSeok; Kim, MinJeong; Lim, JungJin; Kang, OnYu; Shetty, K Vidya; SankaraRao, B; Yoo, ChangKyoo; Park, Jae Hyung; Kim, Jeong Tai
2012-05-01
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.
Latif, Mohd Talib; Baharudin, Nor Hafizah; Velayutham, Puvaneswary; Awang, Normah; Hamdan, Harimah; Mohamad, Ruqyyah; Mokhtar, Mazlin B
2011-10-01
The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM₁₀) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM₁₀ recorded in the building during renovation action (ranging from 166 to 542 μg m⁻³) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m⁻³). Additionally, they were higher than the value of PM₁₀ recorded in indoor environments from other studies. The composition of heavy metals in PM₁₀ and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM₁₀ in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously by relevant stakeholders within the university in order to ensure that the associated risks toward humans and indoor environment are eliminated, or where this is not feasible, minimized as far as possible.
Improvements for rotary viscous dampers used in spacecraft deployment mechanisms
NASA Technical Reports Server (NTRS)
Stewart, Alphonso; Powers, Charles; Lyons, Ron
1998-01-01
During component level thermal-vacuum deployment testing of eight rotary viscous dampers for the Tropical Rainfall Measuring Mission (TRMM) satellite, all the dampers failed to provide damping during a region of the deployment. Radiographic examination showed that air in the damping fluid caused the undamped motion when the dampers were operated in a vacuum environment. Improvements in the procedure used to fill the dampers with damping fluid, the installation of a Viton vacuum seal in the damper cover, and improved screening techniques eliminated the problem.
AN OVERVIEW OF INDOOR RADON RISK REDUCTION IN THE UNITED STATES
Radon in the indoor environment is a recognized environmental hazard. The Environmental Protection Agency (EPA) has established several programs to develop, demonstrate, and transfer radon mitigation technology. Administration and management of these programs are shared by EPA's ...
PENETRATION OF AMBIENT FINE PARTICLES INTO THE INDOOR ENVIRONMENT
Several recent studies have indicated significant health risks associated with exposure to fine particles as measured outdoors. However, much of the exposure is believed to have occurred infdoors. consequently, there is considerable interest in the relationship between indoor a...
ERIC Educational Resources Information Center
Kennedy, Mike
2001-01-01
Shows how schools are working to avoid the types of equipment, supplies, and maintenance practices that harm indoor air quality. Simple steps to maintaining a cleaner indoor air environment are highlighted as are steps to reducing the problem air quality and the occurrence of asthma. (GR)
Constructing an Indoor Floor Plan Using Crowdsourcing Based on Magnetic Fingerprinting
Zhao, Fang; Jiang, Mengling; Ma, Hao; Zhang, Yuexia
2017-01-01
A large number of indoor positioning systems have recently been developed to cater for various location-based services. Indoor maps are a prerequisite of such indoor positioning systems; however, indoor maps are currently non-existent for most indoor environments. Construction of an indoor map by external experts excludes quick deployment and prevents widespread utilization of indoor localization systems. Here, we propose an algorithm for the automatic construction of an indoor floor plan, together with a magnetic fingerprint map of unmapped buildings using crowdsourced smartphone data. For floor plan construction, our system combines the use of dead reckoning technology, an observation model with geomagnetic signals, and trajectory fusion based on an affinity propagation algorithm. To obtain the indoor paths, the magnetic trajectory data obtained through crowdsourcing were first clustered using dynamic time warping similarity criteria. The trajectories were inferred from odometry tracing, and those belonging to the same cluster in the magnetic trajectory domain were then fused. Fusing these data effectively eliminates the inherent tracking errors originating from noisy sensors; as a result, we obtained highly accurate indoor paths. One advantage of our system is that no additional hardware such as a laser rangefinder or wheel encoder is required. Experimental results demonstrate that our proposed algorithm successfully constructs indoor floor plans with 0.48 m accuracy, which could benefit location-based services which lack indoor maps. PMID:29156639
Karunasena, Enusha; Larrañaga, Michael D; Simoni, Jan S; Douglas, David R; Straus, David C
2010-12-01
Damage to human neurological system cells resulting from exposure to mycotoxins confirms a previously controversial public health threat for occupants of water-damaged buildings. Leading scientific organizations disagree about the ability of inhaled mycotoxins in the indoor environment to cause adverse human health effects. Damage to the neurological system can result from exposure to trichothecene mycotoxins in the indoor environment. This study demonstrates that neurological system cell damage can occur from satratoxin H exposure to neurological cells at exposure levels that can be found in water-damaged buildings contaminated with fungal growth. The constant activation of inflammatory and apoptotic pathways at low levels of exposure in human brain capillary endothelial cells, astrocytes, and neural progenitor cells may amplify devastation to neurological tissues and lead to neurological system cell damage from indirect events triggered by the presence of trichothecenes.
Influence of Indoor Hygrothermal Conditions on Human Quality of Life in Social Housing.
Soares, Sara; Fraga, Silvia; Delgado, Joao M P Q; Ramos, Nuno M M
2015-11-17
Modern societies spend most of their time indoors, namely at home, and the indoor environment quality turns out to be a crucial factor to health, quality of life and well-being of the residents. The present study aims to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals' health. This study case will rely on the following assessments in both rehabilitated and non-rehabilitated social housing: i) field measurements, in social dwellings (namely temperature, relative humidity, carbon dioxide concentration, air velocity, air change rate, level of mould spores and energy consumption); ii) residents' questionnaires on social, demogaphic, behavioural, health characteristics and quality of life. Also, iii) qualitative interviews performed with social housing residents from the rehabilitated houses, addressing the self-perception of living conditions and their influence in health status and quality of life. All the collected information will be combined and analysed in order to achieve the main objective. It is expected to define a Predicted Human Life Quality (PHLQ) index, that combines physical parameters describing the indoor environment measured through engineering techniques with residents' and neighbourhood quality of life characteristics assessed by health questionnaires. Improvement in social housing should be related with better health indicators and the new index might be an important tool contributing to enhance quality of life of the residents. Significance for public healthThis study will contribute to understand how indoor environment relates with quality of life and how improving housing conditions impacts on individuals' health, in social housing neighbourhoods. As so, it is important to share the undertaken methodology carried out by a multidisciplinary team, in order to allow other researchers following comparable studies to adopt a similar approach. The case study results will allow to define building rehabilitation policies, improving residents' quality of life and adding great contribution to public health promotion.
NASA Astrophysics Data System (ADS)
Wang, Guodong; Dong, Shuanglin; Tian, Xiangli; Gao, Qinfeng; Wang, Fang
2015-06-01
Emergy analysis is effective for analyzing ecological economic systems. However, the accuracy of the approach is affected by the diversity of economic level, meteorological and hydrological parameters in different regions. The present study evaluated the economic benefits, environmental impact, and sustainability of indoor, semi-intensive and extensive farming systems of sea cucumber ( Apostichopus japonicus) in the same region. The results showed that A. japonicus indoor farming system was high in input and output (yield) whereas pond extensive farming system was low in input and output. The output/input ratio of indoor farming system was lower than that of pond extensive farming system, and the output/input ratio of semi-intensive farming system fell in between them. The environmental loading ratio of A. japonicus extensive farming system was lower than that of indoor farming system. In addition, the emergy yield and emergy exchange ratios, and emergy sustainability and emergy indexes for sustainable development were higher in extensive farming system than those in indoor farming system. These results indicated that the current extensive farming system exerted fewer negative influences on the environment, made more efficient use of available resources, and met more sustainable development requirements than the indoor farming system. A. japonicus farming systems showed more emergy benefits than fish farming systems. The pond farming systems of A. japonicus exploited more free local environmental resources for production, caused less potential pressure on the local environment, and achieved higher sustainability than indoor farming system.
NASA Astrophysics Data System (ADS)
Gligorovski, Sasho; Abbatt, Jonathan P. D.
2018-02-01
In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.
Reactive indoor air chemistry and health-A workshop summary.
Wells, J R; Schoemaecker, C; Carslaw, N; Waring, M S; Ham, J E; Nelissen, I; Wolkoff, P
2017-11-01
The chemical composition of indoor air changes due to the reactive nature of the indoor environment. Historically, only the stable parent compounds were investigated due to their ease of measurement by conventional methods. Today, however, scientists can better characterize oxidation products (gas and particulate-phase) formed by indoor chemistry. An understanding of occupant exposure can be developed through the investigation of indoor oxidants, the use of derivatization techniques, atmospheric pressure detection, the development of real-time technologies, and improved complex modeling techniques. Moreover, the connection between exposure and health effects is now receiving more attention from the research community. Nevertheless, a need still exists for improved understanding of the possible link between indoor air chemistry and observed acute or chronic health effects and long-term effects such as work-related asthma. Published by Elsevier GmbH.
NASA Astrophysics Data System (ADS)
Seeley, Charles; Coutu, André; Monette, Christine; Nennemann, Bernd; Marmont, Hugues
2012-03-01
Hydroelectric power generation is an important non-fossil fuel power source to help meet the world’s energy needs. Fluid-structure interaction (FSI), in the form of mass loading and damping, governs the dynamic response of water turbines, such as Francis turbines. Although the effects of fluid mass loading are well documented, fluid damping is also a critical quantity that may limit vibration amplitudes during service, and therefore help to avoid premature failure of the turbines. However, fluid damping has received less attention in the literature. This paper presents an experimental investigation of damping due to FSI. Three hydrofoils were designed and built to investigate damping due to FSI. Piezoelectric actuation using macrofiber composites (MFCs) provided excitation to the hydrofoil test structure, independent of the flow conditions, to overcome the noisy environment. Natural frequency and damping estimates were experimentally obtained from sine sweep frequency response functions measured with a laser vibrometer through a window in the test section. The results indicate that, although the natural frequencies were not substantially affected by the flow, the damping ratios were observed to increase in a linear manner with respect to flow velocity.
Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini
2014-05-01
Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)). Copyright © 2014 Elsevier Ltd. All rights reserved.
Antifungal properties of essential oils for improvement of indoor air quality: a review.
Whiley, Harriet; Gaskin, Sharyn; Schroder, Tiffany; Ross, Kirstin
2018-03-28
Concerns regarding indoor air quality, particularly the presence of fungi and moulds, are increasing. The potential for essential oils to reduce, control or remove fungi, is gaining interest as they are seen as a "natural" alternative to synthetic chemical fungicides. This review examines published research on essential oils as a method of fungal control in indoor environments. It was difficult to compare the relative performances of essential oils due to differences in research methods and reporting languages. In addition, there are limited studies that scale up laboratory results and assess the efficacy of essential oils within building environments. However, generally, there appears to be some evidence to support the essential oils clove oil, tea tree oil, oregano, thyme and lemon as potential antifungal agents. Essential oils from heartwood, marjoram, cinnamon, lemon basil, caraway, bay tree, fir, peppermint, pine, cedar leaf and manuka were identified in at least one study as having antifungal potential. Future studies should focus on comparing the effectiveness of these essential oils against a large number of fungal isolates from indoor environments. Studies will then need to focus on translating these results into realistic application methods, in actual buildings, and assess the potential for long-term antifungal persistence.
Zhu, Jiping; Feng, Yong-Lai; Aikawa, Bio
2004-11-01
An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).
The Guide for Clinicians was designed to help the healthcare provider address patients with illnesses related to mold in the indoor environment by providing background understanding of how mold may be affecting patients.
A Mandate for Change in the Library Environment.
ERIC Educational Resources Information Center
Silberman, Richard M.
1993-01-01
The problem of indoor air quality and sick-building syndrome in libraries is explained in terms of human health and comfort and the preservation of books and manuscripts. Ventilation and indoor pollutants are discussed, and a proactive strategy of prevention is recommended. (EAM)
Secondhand Tobacco Smoke and Smoke-free Homes
... asthma trigger. Eliminating secondhand smoke from the indoor environment will improve the indoor air quality. View the 1992 EPA Risk Assessment (PDF) (525 pp, 4 MB, About PDF ) , U.S. EPA, Office of Research and Development, Office of Health and Environmental Assessment, Washington, DC, ...
ERIC Educational Resources Information Center
Mahoney, Daniel P.
2008-01-01
Healthful indoor air quality (IAQ) in education facilities can improve the learning environment for students, enhance teacher job satisfaction, and reduce staff complaints. A proactive indoor air quality program helps identify and eliminate conditions that could lead to IAQ complaints, building-related illnesses, and workers' compensation claims.…
Somppi, Taija Liisa
2017-01-01
Long-term exposure to dampness microbiota induces multi-organ morbidity. One of the symptoms related to this disorder is non-thyroidal illness syndrome (NTIS). A retrospective study was carried out in nine patients with a history of mold exposure, experiencing chronic fatigue, cognitive disorder, and different kinds of hypothyroid symptoms despite provision of levothyroxine (3,5,3′,5′-tetraiodothyronine, LT4) monotherapy. Exposure to volatile organic compounds present in water-damaged buildings including metabolic products of toxigenic fungi and mold-derived inflammatory agents can lead to a deficiency or imbalance of many hormones, such as active T3 hormone. Since the 1970s, the synthetic prohormone, levothyroxine (LT4), has been the most commonly prescribed thyroid hormone in replacement monotherapy. It has been presumed that the peripheral conversion of T4 (3,5,3′,5′-tetraiodothyronine) into T3 (3,5,3′-triiodothyronine) is sufficient to satisfy the overall tissue requirements. However, evidence is presented that this not the case for all patients, especially those exposed to indoor air molds. This retrospective study describes the successful treatment of nine patients in whom NTIS was treated with T3-based thyroid hormone. The treatment was based on careful interview, clinical monitoring, and laboratory analysis of serum free T3 (FT3), reverse T3 (rT3) and thyroid-stimulating hormone, free T4, cortisol, and dehydroepiandrosterone (DHEA) values. The ratio of FT3/rT3 was calculated. In addition, some patients received adrenal support with hydrocortisone and DHEA. All patients received nutritional supplementation and dietary instructions. During the therapy, all nine patients reported improvements in all of the symptom groups. Those who had residual symptoms during T3-based therapy remained exposed to indoor air molds in their work places. Four patients were unable to work and had been on disability leave for a long time during LT4 monotherapy. However, during the T3-based and supportive therapy, all patients returned to work in so-called “healthy” buildings. The importance of avoiding mycotoxin exposure via the diet is underlined as DIO2 genetic polymorphism and dysfunction of DIO2 play an important role in the development of symptoms that can be treated successfully with T3 therapy. PMID:28824644
Somppi, Taija Liisa
2017-01-01
Long-term exposure to dampness microbiota induces multi-organ morbidity. One of the symptoms related to this disorder is non-thyroidal illness syndrome (NTIS). A retrospective study was carried out in nine patients with a history of mold exposure, experiencing chronic fatigue, cognitive disorder, and different kinds of hypothyroid symptoms despite provision of levothyroxine (3,5,3',5'-tetraiodothyronine, LT4) monotherapy. Exposure to volatile organic compounds present in water-damaged buildings including metabolic products of toxigenic fungi and mold-derived inflammatory agents can lead to a deficiency or imbalance of many hormones, such as active T3 hormone. Since the 1970s, the synthetic prohormone, levothyroxine (LT4), has been the most commonly prescribed thyroid hormone in replacement monotherapy. It has been presumed that the peripheral conversion of T4 (3,5,3',5'-tetraiodothyronine) into T3 (3,5,3'-triiodothyronine) is sufficient to satisfy the overall tissue requirements. However, evidence is presented that this not the case for all patients, especially those exposed to indoor air molds. This retrospective study describes the successful treatment of nine patients in whom NTIS was treated with T3-based thyroid hormone. The treatment was based on careful interview, clinical monitoring, and laboratory analysis of serum free T3 (FT3), reverse T3 (rT3) and thyroid-stimulating hormone, free T4, cortisol, and dehydroepiandrosterone (DHEA) values. The ratio of FT3/rT3 was calculated. In addition, some patients received adrenal support with hydrocortisone and DHEA. All patients received nutritional supplementation and dietary instructions. During the therapy, all nine patients reported improvements in all of the symptom groups. Those who had residual symptoms during T3-based therapy remained exposed to indoor air molds in their work places. Four patients were unable to work and had been on disability leave for a long time during LT4 monotherapy. However, during the T3-based and supportive therapy, all patients returned to work in so-called "healthy" buildings. The importance of avoiding mycotoxin exposure via the diet is underlined as DIO2 genetic polymorphism and dysfunction of DIO2 play an important role in the development of symptoms that can be treated successfully with T3 therapy.
Concepts and effects of damping in isolators
NASA Technical Reports Server (NTRS)
Kerley, J.
1984-01-01
A series of innovative designs and inventions which led to the solution of many aerospace vibration and shock problems through damping techniques is presented. The design of damped airborne structures has presented a need for such creative innovation. The primary concern was to discover what concepts were necessary for good structural damping. Once these concepts are determined and converted into basic principles, the design of hardware follows. The following hardware and techniques were developed in support of aerospace program requirements: shipping containers, alignment cables for precision mechanisms, isolation of small components such as relays and flight instruments, isolation for heavy flight equipment, coupling devices, universal joints, use of wire mesh to replace cable, isolation of 16-dB, 5000 lb horn, and compound damping devices to get better isolation from shock and vibration in a high steady environment.
Occurrence, sources and human exposure assessment of SCCPs in indoor dust of northeast China.
Liu, Li-Hua; Ma, Wan-Li; Liu, Li-Yan; Huo, Chun-Yan; Li, Wen-Long; Gao, Chong-Jing; Li, Hai-Ling; Li, Yi-Fan; Chan, Hing Man
2017-06-01
Short-chain chlorinated paraffins (SCCPs) are widely used chemicals in household products and might cause adverse human health effects. However, limited information is available on the occurrence of SCCPs in indoor environments and their exposure risks on humans. In this study the concentrations, profiles and human exposure of SCCPs in indoor dust from five different indoor environments, including commercial stores, residential apartments, dormitories, offices and laboratories were characterized. The SCCPs levels ranged from 10.1 to 173.0 μg/g, with the median and mean concentration of 47.2 and 53.6 μg/g, respectively. No significant difference was found on concentrations among the five microenvironments. The most abundant compounds in indoor dust samples were homologues of C 13 group, Cl 7 group and N 20 (N is the total number of C and Cl) group. In the five microenvironments, commercial stores were more frequently exposed to shorter carbon chained and higher chlorinated homologues. Three potential sources for SCCPs were identified by the multiple linear regression of factor score model and correspondence analysis. The major sources of SCCPs in indoor dust were technical mixtures of CP-42 (42% chlorine, w/w) and CP-52 b (52% chlorine, w/w). The total daily exposure doses and hazard quotients (HQ) were calculated by the human exposure models, and they were all below the reference doses and threshold values, respectively. Monte Carlo simulation was applied to predict the human exposure risk of SCCPs. Infants and toddlers were at risk of SCCPs based on predicted HQ values, which were exceeded the threshold for neoplastic effects in the worst case. Our results on the occurrences, sources and human exposures of SCCPs will be useful to provide a better understanding of SCCPs behaviors in indoor environment in China, and to support environmental risk evaluation and regulation of SCCPs in the world. Copyright © 2017. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Pal, Suvajit; Ghosh, Manas
2014-07-01
We investigate the profiles of diagonal components of static and frequency-dependent third nonlinear (γxxxx and γyyyy) polarizability of repulsive impurity doped quantum dots. The dopant impurity potential takes a GAUSSIAN form. We have considered propagation of the dopant within an environment that damps the motion. The study focuses on role of damping strength on the diagonal components of both static and frequency-dependent third nonlinear polarizability of the doped system. The doped system is further exposed to an external electric field of given intensity. Damping subtly modulates the dot-impurity interaction and fabricates the polarizability components in a noticeable manner.
Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology.
Hsu, Yu-Liang; Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen
2017-07-15
This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents' wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident's feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment.
LeBouf, Ryan; Yesse, Liesel; Rossner, Alan
2008-05-01
It is well known that characterization of airborne bioaerosols in indoor environments is a challenge because of inherent irregularity in concentrations, which are influenced by many environmental factors. The primary aim of this study was to quantify the day-to-day variability of airborne fungal levels in a single residential environment over multiple seasons. Indoor air quality practitioners must recognize the inherent variability in airborne bio-aerosol measurements during data analysis of mold investigations. Changes in airborne fungi due to varying season and day is important to recognize when considering health impacts of these contaminants and when establishing effective controls. Using an Andersen N6 impactor, indoor and outdoor bioaerosol samples were collected on malt extract agar plates for 18 weekdays and 19 weekdays in winter and summer, respectively. Interday and intraday variability for the bioaerosols were determined for each sampler. Average fungal concentrations were 26 times higher during the summer months. Day-to-day fungal samples showed a relatively high inconsistency suggesting airborne fungal levels are very episodic and are influenced by several environmental factors. Summer bio-aerosol variability ranged from 7 to 36% and winter variability from 24 to 212%; these should be incorporated into results of indoor mold investigations. The second objective was to observe the relationship between biological and nonbiological particulate matter (PM). No correlation was observed between biological and nonbiological PM. Six side-by-side particulate samplers collected coarse PM (PM10) and fine PM (PM2.5) levels in both seasons. PM2.5 particulate concentrations were found to be statistically higher during summer months. Interday variability observed during this study suggests that indoor air quality practitioners must adjust their exposure assessment strategies to reflect the temporal variability in bioaerosol concentrations.
Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology
Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen
2017-01-01
This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents’ wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident’s feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment. PMID:28714884
Xiong, Lilin; Huang, Xiao; Li, Jie; Mao, Peng; Wang, Xiang; Wang, Rubing; Tang, Meng
2018-06-13
Indoor physical environments appear to influence learning efficiency nowadays. For improvement in learning efficiency, environmental scenarios need to be designed when occupants engage in different learning tasks. However, how learning efficiency is affected by indoor physical environment based on task types are still not well understood. The present study aims to explore the impacts of three physical environmental factors (i.e., temperature, noise, and illuminance) on learning efficiency according to different types of tasks, including perception, memory, problem-solving, and attention-oriented tasks. A 3 × 4 × 3 full factorial design experiment was employed in a university classroom with 10 subjects recruited. Environmental scenarios were generated based on different levels of temperature (17 °C, 22 °C, and 27 °C), noise (40 dB(A), 50 dB(A), 60 dB(A), and 70 dB(A)) and illuminance (60 lx, 300 lx, and 2200 lx). Accuracy rate (AC), reaction time (RT), and the final performance indicator (PI) were used to quantify learning efficiency. The results showed ambient temperature, noise, and illuminance exerted significant main effect on learning efficiency based on four task types. Significant concurrent effects of the three factors on final learning efficiency was found in all tasks except problem-solving-oriented task. The optimal environmental scenarios for top learning efficiency were further identified under different environmental interactions. The highest learning efficiency came in thermoneutral, relatively quiet, and bright conditions in perception-oriented task. Subjects performed best under warm, relatively quiet, and moderately light exposure when recalling images in the memory-oriented task. Learning efficiency peaked to maxima in thermoneutral, fairly quiet, and moderately light environment in problem-solving process while in cool, fairly quiet and bright environment with regard to attention-oriented task. The study provides guidance for building users to conduct effective environmental intervention with simultaneous controls of ambient temperature, noise, and illuminance. It contributes to creating the most suitable indoor physical environment for improving occupants learning efficiency according to different task types. The findings could further supplement the present indoor environment-related standards or norms with providing empirical reference on environmental interactions.
Climate change and health: Indoor heat exposure in vulnerable populations☆
White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Dvonch, J. Timothy; O'Neill, Marie S.
2015-01-01
Introduction Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures’ responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings PMID:22071034
Occurrence of endocrine-disrupting chemicals in indoor dust
Hwang, Hyun-Min; Park, Eun-Kee; Young, Thomas M.; Hammock, Bruce D.
2010-01-01
Human exposure to indoor dust enriched with endocrine-disrupting chemicals released from numerous indoor sources has been a focus of increasing concern. Longer residence times and elevated contaminant concentrations in the indoor environment may increase chances of exposure to these contaminants by 1000-fold compared to outdoor exposure. To investigate the occurrence of semi-volatile endocrine-disrupting chemicals, including PBDEs (polybrominated diphenyl ethers), PCBs (polychlorinated biphenyls), phthalates, pyrethroids, DDT (dichlorodiphenyltrichloroethane) and its metabolites, and chlordanes, indoor dust samples were collected from household vacuum cleaner bags provided by 10 apartments and 1 community hall in Davis, California, USA. Chemical analyses show that all indoor dust samples are highly contaminated by target analytes measured in the present study. Di-(2-ethylhexyl)phthalate was the most abundant (104–7630 μg/g) in all samples and higher than other target analytes by 2 to 6 orders of magnitude. PBDEs were also found at high concentrations (1780–25,200 ng/g). Although the use of PCBs has been banned or restricted for decades, some samples had PCBs at levels that are considered to be concerns for human health, indicating that the potential risk posed by PCBs still remains high in the indoor environment, probably due to a lack of dissipation processes and continuous release from the sources. Although the use of some PBDEs is being phased out in some parts of the U.S., this trend may apply to PBDEs as well. We can anticipate that exposure to PBDEs will continue as long as the general public keeps using existing household items such as sofas, mattresses, and carpets that contain PBDEs. This study provides additional information that indoor dust is highly contaminated by persistent and endocrine-disrupting chemicals. PMID:18632138
NASA Astrophysics Data System (ADS)
Tasić, Viša; Jovašević-Stojanović, Milena; Vardoulakis, Sotiris; Milošević, Novica; Kovačević, Renata; Petrović, Jelena
2012-07-01
Accurate monitoring of indoor mass concentrations of particulate matter is very important for health risk assessment as people in developed countries spend approximately 90% of their time indoors. The direct reading, aerosol monitoring device, Turnkey, OSIRIS Particle Monitor (Model 2315) and the European reference low volume sampler, LVS3 (Sven/Leckel LVS3) with size-selective inlets for PM10 and PM2.5 fractions were used to assess the comparability of available optical and gravimetric methods for particulate matter characterization in indoor air. Simultaneous 24-hour samples were collected in an indoor environment for 60 sampling periods in the town of Bor, Serbia. The 24-hour mean PM10 levels from the OSIRIS monitor were well correlated with the LVS3 levels (R2 = 0.87) and did not show statistically significant bias. The 24-hour mean PM2.5 levels from the OSIRIS monitor were moderately correlated with the LVS3 levels (R2 = 0.71), but show statistically significant bias. The results suggest that the OSIRIS monitor provides sufficiently accurate measurements for PM10. The OSIRIS monitor underestimated the indoor PM10 concentrations by approximately 12%, relative to the reference LVS3 sampler. The accuracy of PM10 measurements could be further improved through empirical adjustment. For the fine fraction of particulate matter, PM2.5, it was found that the OSIRIS monitor underestimated indoor concentrations by approximately 63%, relative to the reference LVS3 sampler. This could lead to exposure misclassification in health effects studies relying on PM2.5 measurements collected with this instrument in indoor environments.
Subedi, Bikram; Sullivan, Kenneth D; Dhungana, Birendra
2017-11-01
The quality of indoor environment has received considerable attention owing to the declining outdoor human activities and the associated public health issues. The prolonged exposure of children in childcare facilities or the occupational exposure of adults to indoor environmental triggers can be a culprit of the pathophysiology of several commonly observed idiopathic syndromes. In this study, concentrations of potentially toxic plasticizers (phthalates as well as non-phthalates) were investigated in 28 dust samples collected from three different indoor environments across the USA. The mean concentrations of non-phthalate plasticizers [acetyl tri-n-butyl citrate (ATBC), di-(2-ethylhexyl) adipate (DEHA), and di-isobutyl adipate (DIBA)] were found at 0.51-880 μg/g for the first time in indoor dust samples from childcare facilities, homes, and salons across the USA. The observed concentrations of these replacement non-phthalate plasticizer were as high as di-(2-ethylhexyl) phthalate, the most frequently detected phthalate plasticizer at highest concentration worldwide, in most of indoor dust samples. The estimated daily intakes of total phthalates (n = 7) by children and toddlers through indoor dust in childcare facilities were 1.6 times higher than the non-phthalate plasticizers (n = 3), whereas estimated daily intake of total non-phthalates for all age groups at homes were 1.9 times higher than the phthalate plasticizers. This study reveals, for the first time, a more elevated (∼3 folds) occupational intake of phthalate and non-phthalate plasticizers through the indoor dust at salons (214 and 285 ng/kg-bw/day, respectively) than at homes in the USA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Object Detection Applied to Indoor Environments for Mobile Robot Navigation.
Hernández, Alejandra Carolina; Gómez, Clara; Crespo, Jonathan; Barber, Ramón
2016-07-28
To move around the environment, human beings depend on sight more than their other senses, because it provides information about the size, shape, color and position of an object. The increasing interest in building autonomous mobile systems makes the detection and recognition of objects in indoor environments a very important and challenging task. In this work, a vision system to detect objects considering usual human environments, able to work on a real mobile robot, is developed. In the proposed system, the classification method used is Support Vector Machine (SVM) and as input to this system, RGB and depth images are used. Different segmentation techniques have been applied to each kind of object. Similarly, two alternatives to extract features of the objects are explored, based on geometric shape descriptors and bag of words. The experimental results have demonstrated the usefulness of the system for the detection and location of the objects in indoor environments. Furthermore, through the comparison of two proposed methods for extracting features, it has been determined which alternative offers better performance. The final results have been obtained taking into account the proposed problem and that the environment has not been changed, that is to say, the environment has not been altered to perform the tests.
Object Detection Applied to Indoor Environments for Mobile Robot Navigation
Hernández, Alejandra Carolina; Gómez, Clara; Crespo, Jonathan; Barber, Ramón
2016-01-01
To move around the environment, human beings depend on sight more than their other senses, because it provides information about the size, shape, color and position of an object. The increasing interest in building autonomous mobile systems makes the detection and recognition of objects in indoor environments a very important and challenging task. In this work, a vision system to detect objects considering usual human environments, able to work on a real mobile robot, is developed. In the proposed system, the classification method used is Support Vector Machine (SVM) and as input to this system, RGB and depth images are used. Different segmentation techniques have been applied to each kind of object. Similarly, two alternatives to extract features of the objects are explored, based on geometric shape descriptors and bag of words. The experimental results have demonstrated the usefulness of the system for the detection and location of the objects in indoor environments. Furthermore, through the comparison of two proposed methods for extracting features, it has been determined which alternative offers better performance. The final results have been obtained taking into account the proposed problem and that the environment has not been changed, that is to say, the environment has not been altered to perform the tests. PMID:27483264
Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju
2014-03-21
A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated.
Neural computing thermal comfort index PMV for the indoor environment intelligent control system
NASA Astrophysics Data System (ADS)
Liu, Chang; Chen, Yifei
2013-03-01
Providing indoor thermal comfort and saving energy are two main goals of indoor environmental control system. An intelligent comfort control system by combining the intelligent control and minimum power control strategies for the indoor environment is presented in this paper. In the system, for realizing the comfort control, the predicted mean vote (PMV) is designed as the control goal, and with chastening formulas of PMV, it is controlled to optimize for improving indoor comfort lever by considering six comfort related variables. On the other hand, a RBF neural network based on genetic algorithm is designed to calculate PMV for better performance and overcoming the nonlinear feature of the PMV calculation better. The formulas given in the paper are presented for calculating the expected output values basing on the input samples, and the RBF network model is trained depending on input samples and the expected output values. The simulation result is proved that the design of the intelligent calculation method is valid. Moreover, this method has a lot of advancements such as high precision, fast dynamic response and good system performance are reached, it can be used in practice with requested calculating error.
Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.
Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia
2013-09-03
Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.
Allergens in indoor air: environmental assessment and health effects.
Carrer, P; Maroni, M; Alcini, D; Cavallo, D
2001-04-10
It has been suggested that the increase in morbidity and mortality for asthma and allergies, may also be due to an increase in exposure to allergens in the modern indoor environment. Indoor allergen exposure is recognised as the most important risk factor for asthma in children. House dust mites, pets, insects, plants, moulds and chemical agents in the indoor environment are important causes of allergic diseases. House dust mites and their debris and excrements that contain the allergens are normally found in the home in beds, mattresses, pillows, carpets and furniture stuffing, but they have also been found in office environments. Domestic animals such as cats, dogs, birds and rodents may cause allergic asthma and rhinoconjunctivitis. The exposure usually occurs in homes, but also in schools and kindergartens where domestic animals are kept as pets or for education; moreover, cat and dog owners can bring allergens to public areas in their clothes. Allergy to natural rubber latex has become an important occupational health concern in recent years, particularly among healthcare workers; when powdered gloves are worn or changed, latex particles get into the air and workers are exposed to latex aerosolised antigens. To assess the environmental risk to allergen exposure or to verify if there is a causal relationship between the immunologic findings in a patient and his/her environmental exposure, sampling from the suspected environment may be necessary.
Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.
Bloom, Erica; Nyman, Eva; Must, Aime; Pehrson, Christina; Larsson, Lennart
2009-11-01
Mycotoxins are toxic, secondary metabolites frequently produced by molds in water-damaged indoor environments. We studied the prevalence of selected, potent mycotoxins and levels of fungal biomass in samples collected from water-damaged indoor environments in Sweden during a 1-year period. One hundred samples of building materials, 18 samples of settled dust, and 37 samples of cultured dust were analyzed for: (a) mycoflora by microscopy and culture; (b) fungal chemical marker ergosterol and hydrolysis products of macrocyclic trichothecenes and trichodermin (verrucarol and trichodermol) by gas chromatography-tandem mass spectrometry; and (c) sterigmatocystin, gliotoxin, aflatoxin B(1), and satratoxin G and H by high performance liquid chromatography-tandem mass spectrometry. Sixty-six percent of the analyzed building materials samples, 11% of the settled dust samples, and 51% of the cultured dust samples were positive for at least one of the studied mycotoxins. In addition, except in the case of gliotoxin, mycotoxin-positive building material samples contained 2-6 times more ergosterol than mycotoxin-negative samples. We show that (a) molds growing on a range of different materials indoors in water-damaged buildings generally produce mycotoxins, and (b) mycotoxin-containing particles in mold-contaminated environments may settle on surfaces above floor level. The mass spectrometry methods used in this study are valuable tools in further research to survey mycotoxin exposure and investigate potential links with health effects.
A flexible routing scheme for patients with topographical disorientation.
Torres-Solis, Jorge; Chau, Tom
2007-11-28
Individuals with topographical disorientation have difficulty navigating through indoor environments. Recent literature has suggested that ambient intelligence technologies may provide patients with navigational assistance through auditory or graphical instructions delivered via embedded devices. We describe an automatic routing engine for such an ambient intelligence system. The method routes patients with topographical disorientation through indoor environments by repeatedly computing the route of minimal cost from the current location of the patient to a specified destination. The cost of a given path not only reflects the physical distance between end points, but also incorporates individual patient abilities, the presence of mobility-impeding physical barriers within a building and the dynamic nature of the indoor environment. We demonstrate the method by routing simulated patients with either topographical disorientation or physical disabilities. Additionally, we exemplify the ability to route a patient from source to destination while taking into account changes to the building interior. When compared to a random walk, the proposed routing scheme offers potential cost-savings even when the patient follows only a subset of instructions. The routing method presented reduces the navigational effort for patients with topographical disorientation in indoor environments, accounting for physical abilities of the patient, environmental barriers and dynamic building changes. The routing algorithm and database proposed could be integrated into wearable and mobile platforms within the context of an ambient intelligence solution.
Aminzadeh, Reza; Thielens, Arno; Bamba, Aliou; Kone, Lamine; Gaillot, Davy Paul; Lienard, Martine; Martens, Luc; Joseph, Wout
2016-07-01
For the first time, response of personal exposimeters (PEMs) is studied under diffuse field exposure in indoor environments. To this aim, both numerical simulations, using finite-difference time-domain method, and calibration measurements were performed in the range of 880-5875 MHz covering 10 frequency bands in Belgium. Two PEMs were mounted on the body of a human male subject and calibrated on-body in an anechoic chamber (non-diffuse) and a reverberation chamber (RC) (diffuse fields). This was motivated by the fact that electromagnetic waves in indoor environments have both specular and diffuse components. Both calibrations show that PEMs underestimate actual incident electromagnetic fields. This can be compensated by using an on-body response. Moreover, it is shown that these responses are different in anechoic chamber and RC. Therefore, it is advised to use an on-body calibration in an RC in future indoor PEM measurements where diffuse fields are present. Using the response averaged over two PEMs reduced measurement uncertainty compared to single PEMs. Following the calibration, measurements in a realistic indoor environment were done for wireless fidelity (WiFi-5G) band. Measured power density values are maximally 8.9 mW/m(2) and 165.8 μW/m(2) on average. These satisfy reference levels issued by the International Commission on Non-Ionizing Radiation Protection in 1998. Power density values obtained by applying on-body calibration in RC are higher than values obtained from no body calibration (only PEMs) and on-body calibration in anechoic room, by factors of 7.55 and 2.21, respectively. Bioelectromagnetics. 37:298-309, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Massey, David D.; Kulshrestha, Aditi; Taneja, Ajay
2013-03-01
The concentration of PM10, PM5.0, PM2.5 and PM1 were measured in the indoor-outdoor environment of rural homes of North central part of India during winter, summer and rainy seasons for the time duration of October 2007 to March 2009. Seven trace metals (Pb, Cd, Ni, Fe, Cr, Mn and Cu) were also determined in PM2.5 from October 2007 to March 2009 in the indoor-outdoor environment. During the study period the annual average concentration for PM10, PM5.0, PM2.5 and PM1 in indoor and outdoor were 242.53 μg m-3 and 217.76 μg m-3, 203.57 μg m-3 and 180.42 μg m-3, 164.60 μg m-3 and 143.07 μg m-3, 106.23 μg m-3 and 105.17 μg m-3 respectively. Concentrations of PM10 and PM2.5 have been compared with prescribed WHO standards and NAAQS standards of India and were found to be much higher. Significant seasonal variations of particulate pollutants were obtained using the monthly average concentration of coarse and fine particulate matter. Indoor/outdoor ratios at the rural sites were also determined with the meteorological parameters like temperature, humidity, wind speed and air exchange rate. Chromium was found to have the highest excess cancer risk in a risk evaluation using an Integrated Risk Information System. Three factors each in indoor and outdoor environment of rural site have been identified using Principal Component Analysis & Positive Matrix Factorization.
POST-APPLICATION EXPOSURE POTENTIAL TO PESTICIDES IN THE RESIDENTIAL ENVIRONMENT
A study to investigate the temporal and spatial distributions of pesticides applied by homeowners and commercial applicators for indoor crack and crevice treatments was initiated by the U.S. EPA in 1999. In participating households, pre- and post-application samples of indoor ...
MCEARD CONTRIBUTION TO ORD ASTHMA RESEARCH INITIATIVE
Beginning in 1998, EPA researchers have worked to examine the role of indoor molds/fungi in children's health. The make-up of the indoor environment is critical to the health of children in general and has a particularly important influence on the incidence and exacerbation of ...
Indoor Residence Times of Semivolatile Organic Compounds: Model Estimation and Field Evaluation
Indoor residence times of semivolatile organic compounds (SVOCs) are a major and mostly unavailable input for residential exposure assessment. We calculated residence times for a suite of SVOCs using a fugacity model applied to residential environments. Residence times depend on...
AN ANALYTICAL METHOD FOR THE MEASUREMENT OF NONVIABLE BIOAEROSOLS
Exposures from indoor environments are a major issue for evaluating total long-term personal exposure to the fine fraction (<2.5 micrometers in aerodynamic diameter) of particulate matter (PM). It is widely accepted in the indoor air quality (IAQ) research community that bioconta...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Indoor Radon Grants (section 306) § 35.700 Purpose. (a... programs that assess and mitigate radon and that aim at reducing radon health risks. Indoor Radon Grant...
Developing a Reference Material for Formaldehyde Emissions Testing; Final Report
Exposure to formaldehyde has been shown to produce broad and potentially severe adverse human health effects. With ubiquitous formaldehyde sources in the indoor environment, formaldehyde concentrations in indoor air are usually higher than outdoors, ranging from 10 to 4000 μg/m3....
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-09-01
The National Institute for Occupational Safety and Health (NIOSH) has compiled the document in response to an increasing number of requests for information about indoor air quality (IAQ), including sick building syndrome. Included in the publication are: NIOSH Congressional testimony that describes the NIOSH IAQ investigations program and summarizes the results of NIOSH research and findings on IAQ problems, NIOSH guidance for conducting indoor air quality investigations, NIOSH journal article on evaluating building ventilation systems, and list of non-NIOSH publications on indoor air quality. As the Federal agency responsible for conducting research and making recommendations for occupational safety and healthmore » standards, NIOSH limits its IAQ activities to the occupational environment. The U.S. Environmental Protection Agency (EPA) also conducts an IAQ program and can be contacted for information regarding both occupational and non-occupational settings.« less
NASA Astrophysics Data System (ADS)
Alsudani, Ahlam
2018-05-01
In recent years, indoor positioning system (IPS) plays a very important role in several environments such as hospitals, airports, males, Etc. It is used to locate mobile stations such as human and robots inside buildings. Some of IPSs applications are: locating an elder or child needed for an urgent help in hospitals, emergency situations such as locating firefighters inside building on fire or policemen fitting terrorists inside building by a commander to help for expedite evacuation in case one of them need for help. In indoor positioning applications, the accuracy should be high as can as possible, in another word; the error should be less than 1 meter. The indoor environment is the major challenging to obtain such accuracy. In this paper, we present a novel algorithm to identify the line of sight (LOS) and non-line of sight (NLOS) channels and improve the positioning accuracy using ultra-wideband (UWB) technology implementing DW1000 devices.
Indoor Pedestrian Navigation Using Foot-Mounted IMU and Portable Ultrasound Range Sensors
Girard, Gabriel; Côté, Stéphane; Zlatanova, Sisi; Barette, Yannick; St-Pierre, Johanne; van Oosterom, Peter
2011-01-01
Many solutions have been proposed for indoor pedestrian navigation. Some rely on pre-installed sensor networks, which offer good accuracy but are limited to areas that have been prepared for that purpose, thus requiring an expensive and possibly time-consuming process. Such methods are therefore inappropriate for navigation in emergency situations since the power supply may be disturbed. Other types of solutions track the user without requiring a prepared environment. However, they may have low accuracy. Offline tracking has been proposed to increase accuracy, however this prevents users from knowing their position in real time. This paper describes a real time indoor navigation system that does not require prepared building environments and provides tracking accuracy superior to previously described tracking methods. The system uses a combination of four techniques: foot-mounted IMU (Inertial Motion Unit), ultrasonic ranging, particle filtering and model-based navigation. The very purpose of the project is to combine these four well-known techniques in a novel way to provide better indoor tracking results for pedestrians. PMID:22164034
Modeling Human Exposure to Indoor Contaminants: External Source to Body Tissues.
Webster, Eva M; Qian, Hua; Mackay, Donald; Christensen, Rebecca D; Tietjen, Britta; Zaleski, Rosemary
2016-08-16
Information on human indoor exposure is necessary to assess the potential risk to individuals from many chemicals of interest. Dynamic indoor and human physicologically based pharmacokinetic (PBPK) models of the distribution of nonionizing, organic chemical concentrations in indoor environments resulting in delivered tissue doses are developed, described and tested. The Indoor model successfully reproduced independently measured, reported time-dependent air concentrations of chloroform released during showering and of 2-butyoxyethanol following use of a volatile surface cleaner. The Indoor model predictions were also comparable to those from a higher tier consumer model (ConsExpo 4.1) for the surface cleaner scenario. The PBPK model successful reproduced observed chloroform exhaled air concentrations resulting from an inhalation exposure. Fugacity based modeling provided a seamless description of the partitioning, fluxes, accumulation and release of the chemical in indoor media and tissues of the exposed subject. This has the potential to assist in health risk assessments, provided that appropriate physical/chemical property, usage characteristics, and toxicological information are available.
[Indoor volatile organic compounds: concentrations, sources, variation factors].
Palot, A; Charpin-Kadouch, C; Ercoli, J; Charpin, D
2008-06-01
Volatile organic compounds (V.O.C.) are part of urban air pollution and are also generated indoors from cleaning and maintenance products. VOC measurements are, on average, 10 times higher within homes than outside. Results of the national survey led by the Observatoire National de la Qualité de l'Air Intérieur demonstrated that up to 25% of French homes have very high or high concentrations of VOC. Indoor levels depend mainly on indoor sources. Aldehydes are included in many everyday life products. VOC originate from various household decorating and cleaning products. Some products are less detrimental to the environment and health and have special labelling. Indoor VOC levels also depend on the rate of air exchange and on household characteristics such as indoor temperature and humidity, age of the building, presence of smokers, and communication with a garage. The public may participate in maintaining good indoor air quality and the authorities should also improve regulations. VOC are part of everyday air pollution. Their sources and concentrations should be better monitored.
Darling, E; Corsi, R L
2017-05-01
Ozone reacts readily with many indoor materials, as well as with compounds in indoor air. These reactions lead to lower indoor than outdoor ozone concentrations when outdoor air is the major contributor to indoor ozone. However, the products of indoor ozone reactions may be irritating or harmful to building occupants. While active technologies exist to reduce indoor ozone concentrations (i.e, in-duct filtration using activated carbon), they can be cost-prohibitive for some and/or infeasible for dwellings that do not have heating, ventilating, and air-conditioning systems. In this study, the potential for passive reduction of indoor ozone by two different clay-based interior surface coatings was explored. These coatings were exposed to occupied residential indoor environments and tested bimonthly in environmental chambers for quantification of ozone reaction probabilities and reaction product emission rates over a 6-month period. Results indicate that clay-based coatings may be effective as passive removal materials, with relatively low by-product emission rates that decay rapidly within 2 months. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Gold, Diane R; Adamkiewicz, Gary; Arshad, Syed Hasan; Celedón, Juan C; Chapman, Martin D; Chew, Ginger L; Cook, Donald N; Custovic, Adnan; Gehring, Ulrike; Gern, James E; Johnson, Christine C; Kennedy, Suzanne; Koutrakis, Petros; Leaderer, Brian; Mitchell, Herman; Litonjua, Augusto A; Mueller, Geoffrey A; O'Connor, George T; Ownby, Dennis; Phipatanakul, Wanda; Persky, Victoria; Perzanowski, Matthew S; Ramsey, Clare D; Salo, Päivi M; Schwaninger, Julie M; Sordillo, Joanne E; Spira, Avrum; Suglia, Shakira F; Togias, Alkis; Zeldin, Darryl C; Matsui, Elizabeth C
2017-10-01
Environmental exposures have been recognized as critical in the initiation and exacerbation of asthma, one of the most common chronic childhood diseases. The National Institute of Allergy and Infectious Diseases; National Institute of Environmental Health Sciences; National Heart, Lung, and Blood Institute; and Merck Childhood Asthma Network sponsored a joint workshop to discuss the current state of science with respect to the indoor environment and its effects on the development and morbidity of childhood asthma. The workshop included US and international experts with backgrounds in allergy/allergens, immunology, asthma, environmental health, environmental exposures and pollutants, epidemiology, public health, and bioinformatics. Workshop participants provided new insights into the biologic properties of indoor exposures, indoor exposure assessment, and exposure reduction techniques. This informed a primary focus of the workshop: to critically review trials and research relevant to the prevention or control of asthma through environmental intervention. The participants identified important limitations and gaps in scientific methodologies and knowledge and proposed and prioritized areas for future research. The group reviewed socioeconomic and structural challenges to changing environmental exposure and offered recommendations for creative study design to overcome these challenges in trials to improve asthma management. The recommendations of this workshop can serve as guidance for future research in the study of the indoor environment and on environmental interventions as they pertain to the prevention and management of asthma and airway allergies. Published by Elsevier Inc.
Zou, Han; Lu, Xiaoxuan; Jiang, Hao; Xie, Lihua
2015-01-01
Nowadays, developing indoor positioning systems (IPSs) has become an attractive research topic due to the increasing demands on location-based service (LBS) in indoor environments. WiFi technology has been studied and explored to provide indoor positioning service for years in view of the wide deployment and availability of existing WiFi infrastructures in indoor environments. A large body of WiFi-based IPSs adopt fingerprinting approaches for localization. However, these IPSs suffer from two major problems: the intensive costs of manpower and time for offline site survey and the inflexibility to environmental dynamics. In this paper, we propose an indoor localization algorithm based on an online sequential extreme learning machine (OS-ELM) to address the above problems accordingly. The fast learning speed of OS-ELM can reduce the time and manpower costs for the offline site survey. Meanwhile, its online sequential learning ability enables the proposed localization algorithm to adapt in a timely manner to environmental dynamics. Experiments under specific environmental changes, such as variations of occupancy distribution and events of opening or closing of doors, are conducted to evaluate the performance of OS-ELM. The simulation and experimental results show that the proposed localization algorithm can provide higher localization accuracy than traditional approaches, due to its fast adaptation to various environmental dynamics. PMID:25599427
Yoon, Ki Young; Park, Chul Woo; Byeon, Jeong Hoon; Hwang, Jungho
2010-03-01
We proposed a rapid method to estimate the efficacies of air controlling devices in situ using ATP bioluminescence in combination with an inertial impactor. The inertial impactor was designed to have 1 mum of cutoff diameter, and its performance was estimated analytically, numerically, and experimentally. The proposed method was characterized using Staphylococcus epidermidis, which was aerosolized with a nebulizer. The bioaerosol concentrations were estimated within 25 min using the proposed method without a culturing process, which requires several days for colony formation. A linear relationship was obtained between the results of the proposed ATP method (RLU/m(3)) and the conventional culture-based method (CFU/m(3)), with R(2) 0.9283. The proposed method was applied to estimate the concentration of indoor bioaerosols, which were identified as a mixture of various microbial species including bacteria, fungi, and actinomycetes, in an occupational indoor environment, controlled by mechanical ventilation and an air cleaner. Consequently, the proposed method showed a linearity with the culture-based method for indoor bioaerosols with R(2) 0.8189, even though various kinds of microorganisms existed in the indoor air. The proposed method may be effective in monitoring the changes of relative concentration of indoor bioaerosols and estimating the effectiveness of air control devices in indoor environments.
Alshami, Iyad Husni; Sahibuddin, Shamsul; Firdaus, Firdaus
2017-01-01
The Global Positioning System demonstrates the significance of Location Based Services but it cannot be used indoors due to the lack of line of sight between satellites and receivers. Indoor Positioning Systems are needed to provide indoor Location Based Services. Wireless LAN fingerprints are one of the best choices for Indoor Positioning Systems because of their low cost, and high accuracy, however they have many drawbacks: creating radio maps is time consuming, the radio maps will become outdated with any environmental change, different mobile devices read the received signal strength (RSS) differently, and peoples’ presence in LOS between access points and mobile device affects the RSS. This research proposes a new Adaptive Indoor Positioning System model (called DIPS) based on: a dynamic radio map generator, RSS certainty technique and peoples’ presence effect integration for dynamic and multi-floor environments. Dynamic in our context refers to the effects of people and device heterogeneity. DIPS can achieve 98% and 92% positioning accuracy for floor and room positioning, and it achieves 1.2 m for point positioning error. RSS certainty enhanced the positioning accuracy for floor and room for different mobile devices by 11% and 9%. Then by considering the peoples’ presence effect, the error is reduced by 0.2 m. In comparison with other works, DIPS achieves better positioning without extra devices. PMID:28783047
Effects of moisture controlled charcoal on indoor thermal and air environments
NASA Astrophysics Data System (ADS)
Matsumoto, Hiroshi; Yokogoshi, Midori; Nabeshima, Yuki
2017-10-01
It is crucial to remove and control indoor moisture in Japan, especially in hot and humid summers, in order to improve thermal comfort and save energy in buildings. Charcoal for moisture control made from the waste of wood material has attracted attention among many control strategies to control indoor moisture, and it is beginning to be used in houses. However, the basic characteristics of the charcoal to control moisture and remove chemical compounds in indoor air have not been investigated sufficiently. The objective of this study is to clarify the effect of moisture control charcoal on indoor thermal and air environments by a long-term field measurement using two housing scale models with/without charcoal in Toyohashi, Japan. The comparative experiments to investigate the effect of the charcoal on air temperature and humidity for two models with/without charcoal were conducted from 2015 to 2016. Also, the removal performance of volatile organic compound (VOCs) was investigated in the summer of 2015. Four bags of packed charcoal were set on the floor in the attic for one model during the experiment. As a result of the experiments, a significant effect of moisture control was observed in hot and humid season, and the efficient effect of moisture adsorption was obtained by the periodic humidification experiment using a humidifier. Furthermore, the charcoal showed a remarkable performance of VOC removal from indoor air by the injection experiment of formaldehyde.
Climate change and health: Indoor heat exposure in vulnerable populations
DOE Office of Scientific and Technical Information (OSTI.GOV)
White-Newsome, Jalonne L., E-mail: jalonne@umich.edu; Sanchez, Brisa N., E-mail: brisa@umich.edu; Jolliet, Olivier, E-mail: ojolliet@umich.edu
2012-01-15
Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 inmore » Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 Degree-Sign C, 13.8 Degree-Sign C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.« less
Analysis of isocyanates in indoor dust.
Bekki, Kanae; Uchiyama, Shigehisa; Kunugita, Naoki
2018-05-04
Isocyanates are harmful semi-volatile organic compounds that are emitted from various consumer products like polyurethane foam-based mattresses. Although it is a concern that isocyanates might accumulate in indoor dust, causing infants and toddlers, in particular, to be exposed to them, little information is available on the levels of isocyanates in the indoor environment. In this study, we investigated the suitability of an analytical method for determining the presence and level of isocyanates in the indoor dust. The method we developed displayed acceptable linearity, accuracy, and precision in the analysis of eleven different isocyanates. By using this analytical method, we could detect five isocyanates (ICA, MIC, EIC, PIC, and PHI) and quantify three isocyanates (MIC, EIC, and PHI) in indoor dust collected in different houses. This study is the first to focus on the pollution of indoor dust by isocyanates, and the tested method is suitable for the estimation of the level of isocyanate exposure. Graphical abstract ᅟ.
Psychotropic substances in indoor environments.
Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia
2014-10-01
The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.
Psychosocial dimensions of solving an indoor air problem.
Lahtinen, Marjaana; Huuhtanen, Pekka; Kähkönen, Erkki; Reijula, Kari
2002-03-01
This investigation focuses on the psychological and social dimensions of managing and solving indoor air problems. The data were collected in nine workplaces by interviews (n = 85) and questionnaires (n = 375). Indoor air problems in office environments have traditionally utilized industrial hygiene or technical expertise. However, indoor air problems at workplaces are often more complex issues to solve. Technical questions are inter-related with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the solving process are also put to the test. In the present study, the interviewees were very critical of the process of solving the indoor air problem. The responsibility for coordinating the problem-managing process was generally considered vague, as were the roles and functions of the various parties. Communication problems occurred and rumors about the indoor air problem circulated widely. Conflicts were common, complicating the process in several ways. The research focused on examining different ways of managing and resolving an indoor air problem. In addition, reference material on the causal factors of the indoor air problem was also acquired. The study supported the hypothesis that psychosocial factors play a significant role in indoor air problems.
Uejio, C. K.; Tamerius, J. D.; Vredenburg, J.; Asaeda, G.; Isaacs, D. A.; Braun, J.; Quinn, A.; Freese, J. P.
2016-01-01
Most extreme heat studies relate outdoor weather conditions to human morbidity and mortality. In developed nations, individuals spend ~90% of their time indoors. This pilot study investigated the indoor environments of people receiving emergency medical care in New York City, NY, U.S., from July to August 2013. The first objective was to determine the relative influence of outdoor conditions as well as patient characteristics and neighborhood sociodemographics on indoor temperature and specific humidity (N = 764). The second objective was to determine whether cardiovascular or respiratory cases experience hotter and more humid indoor conditions as compared to controls. Paramedics carried portable sensors into buildings where patients received care to passively monitor indoor temperature and humidity. The case–control study compared 338 respiratory cases, 291 cardiovascular cases, and 471 controls. Intuitively, warmer and sunnier outdoor conditions increased indoor temperatures. Older patients who received emergency care tended to occupy warmer buildings. Indoor-specific humidity levels quickly adjusted to outdoor conditions. Indoor heat and humidity exposure above a 26 °C threshold increased (OR: 1.63, 95% CI: 0.98–2.68, P = 0.056), but not significantly, the proportion of respiratory cases. Indoor heat exposures were similar between cardiovascular cases and controls. PMID:26086869
Mobile indoor localization using Kalman filter and trilateration technique
NASA Astrophysics Data System (ADS)
Wahid, Abdul; Kim, Su Mi; Choi, Jaeho
2015-12-01
In this paper, an indoor localization method based on Kalman filtered RSSI is presented. The indoor communications environment however is rather harsh to the mobiles since there is a substantial number of objects distorting the RSSI signals; fading and interference are main sources of the distortion. In this paper, a Kalman filter is adopted to filter the RSSI signals and the trilateration method is applied to obtain the robust and accurate coordinates of the mobile station. From the indoor experiments using the WiFi stations, we have found that the proposed algorithm can provide a higher accuracy with relatively lower power consumption in comparison to a conventional method.
Extracting Topological Relations Between Indoor Spaces from Point Clouds
NASA Astrophysics Data System (ADS)
Tran, H.; Khoshelham, K.; Kealy, A.; Díaz-Vilariño, L.
2017-09-01
3D models of indoor environments are essential for many application domains such as navigation guidance, emergency management and a range of indoor location-based services. The principal components defined in different BIM standards contain not only building elements, such as floors, walls and doors, but also navigable spaces and their topological relations, which are essential for path planning and navigation. We present an approach to automatically reconstruct topological relations between navigable spaces from point clouds. Three types of topological relations, namely containment, adjacency and connectivity of the spaces are modelled. The results of initial experiments demonstrate the potential of the method in supporting indoor navigation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants State Indoor Radon Grants (section 306) § 35.290 Purpose. (a) Purpose... mitigate radon and that aim at reducing radon health risks. State Indoor Radon Grant funds may be used for...
The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.
Long-term integrating samplers for indoor air and sub slab soil gas at VI sites
Vapor intrusion (VI) site assessments are plagued by substantial spatial and temporal variability that makes exposure and risk assessment difficult. Most risk-based decision making for volatile organic compound (VOC) exposure in the indoor environment is based on health benchmark...
Abstract Both Streptomyces species and mold species have previously been isolated from moisture-damaged building materials; however, an association between these two groups of microorganisms in indoor environments is not clear. In this study, we used a cultureindependent met...
Gut, Ian M; Bartlett, Ryan A; Yeager, John J; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul; Karaolis, David K R
2016-05-01
Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies,Yersinia pestis persistence as a function of surface type at 21 °C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Bartlett, Ryan A.; Yeager, John J.; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul
2016-01-01
ABSTRACT Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies, Yersinia pestis persistence as a function of surface type at 21°C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. IMPORTANCE Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis. The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. PMID:26944839
Ubiquitous Indoor Geolocation: a Case Study of Jewellery Management System
NASA Astrophysics Data System (ADS)
Nikparvar, B.; Sadeghi-Niaraki, A.; Azari, P.
2014-10-01
Addressing and geolocation for indoor environments are important fields of research in the recent years. The problem of finding location of objects in indoor spaces is proposed to solve in two ways. The first, is to assign coordinates to objects and second is to divide space into cells and detect the presence or absence of objects in each cell to track them. In this paper the second approach is discussed by using Radio Frequency Identification technology to identify and track high value objects in jewellery retail industry. In Ubiquitous Sensor Networks, the reactivity or proactivity of the environment are important issues. Reactive environments wait for a request to response to it. Instead, in proactive spaces, the environment acts in advance to deal with an expected action. In this research, a geo-sensor network containing RFID readers, tags, and antennas which continuously exchange radio frequency signal streams is proposed to manage and monitor jewellery galleries ubiquitously. The system is also equipped with a GIS representation which provides a more user-friendly system to manage a jewellery gallery.
Indoor space 3D visual reconstruction using mobile cart with laser scanner and cameras
NASA Astrophysics Data System (ADS)
Gashongore, Prince Dukundane; Kawasue, Kikuhito; Yoshida, Kumiko; Aoki, Ryota
2017-02-01
Indoor space 3D visual reconstruction has many applications and, once done accurately, it enables people to conduct different indoor activities in an efficient manner. For example, an effective and efficient emergency rescue response can be accomplished in a fire disaster situation by using 3D visual information of a destroyed building. Therefore, an accurate Indoor Space 3D visual reconstruction system which can be operated in any given environment without GPS has been developed using a Human-Operated mobile cart equipped with a laser scanner, CCD camera, omnidirectional camera and a computer. By using the system, accurate indoor 3D Visual Data is reconstructed automatically. The obtained 3D data can be used for rescue operations, guiding blind or partially sighted persons and so forth.
2013-01-01
Background Low absolute humidity (AH) has been associated with increased influenza virus survival and transmissibility and the onset of seasonal influenza outbreaks. Humidification of indoor environments may mitigate viral transmission and may be an important control strategy, particularly in schools where viral transmission is common and contributes to the spread of influenza in communities. However, the variability and predictors of AH in the indoor school environment and the feasibility of classroom humidification to levels that could decrease viral survival have not been studied. Methods Automated sensors were used to measure temperature, humidity and CO2 levels in two Minnesota grade schools without central humidification during two successive winters. Outdoor AH measurements were derived from the North American Land Data Assimilation System. Variability in indoor AH within classrooms, between classrooms in the same school, and between schools was assessed using concordance correlation coefficients (CCC). Predictors of indoor AH were examined using time-series Auto-Regressive Conditional Heteroskedasticity models. Classroom humidifiers were used when school was not in session to assess the feasibility of increasing indoor AH to levels associated with decreased influenza virus survival, as projected from previously published animal experiments. Results AH varied little within classrooms (CCC >0.90) but was more variable between classrooms in the same school (CCC 0.81 for School 1, 0.88 for School 2) and between schools (CCC 0.81). Indoor AH varied widely during the winter (range 2.60 to 10.34 millibars [mb]) and was strongly associated with changes in outdoor AH (p < 0.001). Changes in indoor AH on school weekdays were strongly associated with CO2 levels (p < 0.001). Over 4 hours, classroom humidifiers increased indoor AH by 4 mb, an increase sufficient to decrease projected 1-hour virus survival by an absolute value of 30% during winter months. Conclusions During winter, indoor AH in non-humidified grade schools varies substantially and often to levels that are very low. Indoor results are predicted by outdoor AH over a season and CO2 levels (which likely reflects human activity) during individual school days. Classroom humidification may be a feasible approach to increase indoor AH to levels that may decrease influenza virus survival and transmission. PMID:23383620
Scene analysis for a breadboard Mars robot functioning in an indoor environment
NASA Technical Reports Server (NTRS)
Levine, M. D.
1973-01-01
The problem is delt with of computer perception in an indoor laboratory environment containing rocks of various sizes. The sensory data processing is required for the NASA/JPL breadboard mobile robot that is a test system for an adaptive variably-autonomous vehicle that will conduct scientific explorations on the surface of Mars. Scene analysis is discussed in terms of object segmentation followed by feature extraction, which results in a representation of the scene in the robot's world model.
1990-09-01
maneuver in a cluttered indoor environment . Since Pluto could position itself in any orientation, it would also allow us to mount a robot arm on top of...reasons. First, it gives the payload a smoother ride: although the robot operates in an indoor environment , there are still cables and door thresholds to...form a self-holding circuit. A small DPDT relay powers the proper indicator light and is also 9 Batery en main Inlet O60A 24VDC Off Board On Board(NO
NASA Technical Reports Server (NTRS)
Min, James B.; Harris, Donald L.; Ting, J. M.
2011-01-01
For advanced aerospace propulsion systems, development of ceramic matrix composite integrally-bladed turbine disk technology is attractive for a number of reasons. The high strength-to-weight ratio of ceramic composites helps to reduce engine weight and the one-piece construction of a blisk will result in fewer parts count, which should translate into reduced operational costs. One shortcoming with blisk construction, however, is that blisks may be prone to high cycle fatigue due to their structural response to high vibration environments. Use of ceramic composites is expected to provide some internal damping to reduce the vibratory stresses encountered due to unsteady flow loads through the bladed turbine regions. A goal of our research was to characterize the vibration viscous damping behavior of C/SiC composites. The vibration damping properties were measured and calculated. Damping appeared to decrease with an increase in the natural frequency. While the critical damping amount of approximately 2% is required for typical aerospace turbomachinery engines, the C/SiC damping at high frequencies was less than 0.2% from our study. The advanced high-performance aerospace propulsion systems almost certainly will require even more damping than what current vehicles require. A purpose of this paper is to review some work on C/SiC vibration damping by the authors for the NASA CMC turbine blisk development program and address an importance of the further investigation of the blade vibration damping characteristics on candidate CMC materials for the NASA s advanced aerospace turbomachinery engine systems.
Gallup, J; Kozak, P; Cummins, L; Gillman, S
1987-01-01
We are constantly being exposed to molds in our environment. Indoor mold problems occur after prolonged or chronic water damage to a variety of organic materials such as unfinished wood, jutebacked carpeting, wallpaper, books, cardboard, leather, cork, paper, wallboard, and wicker baskets. Mechanisms for spore dispersal (such as air currents or foot traffic on carpets) must also be present. The presence of these organic materials and dispersal mechanisms leads to significant increases in indoor spore levels.
Description of and preliminary tests results for the Joint Damping Experiment (JDX)
NASA Technical Reports Server (NTRS)
Bingham, Jeffrey G.; Folkman, Steven L.
1995-01-01
An effort is currently underway to develop an experiment titled joint Damping E_periment (JDX) to fly on the Space Shuttle as Get Away Special Payload G-726. This project is funded by NASA's IN-Space Technology Experiments Program and is scheduled to fly in July 1995 on STS-69. JDX will measure the influence of gravity on the structural damping of a three bay truss having clearance fit pinned joints. Structural damping is an important parameter in the dynamics of space structures. Future space structures will require more precise knowledge of structural damping than is currently available. The mission objectives are to develop a small-scale shuttle flight experiment that allows researchers to: (1) characterize the influence of gravity and joint gaps on structural damping and dynamic behavior of a small-scale truss model, and (2) evaluate the applicability of low-g aircraft test results for predicting on-orbit behavior. Completing the above objectives will allow a better understanding and/or prediction of structural damping occurring in a pin jointed truss. Predicting damping in joints is quite difficult. One of the important variables influencing joint damping is gravity. Previous work has shown that gravity loads can influence damping in a pin jointed truss structure. Flying this experiment as a GAS payload will allow testing in a microgravity environment. The on-orbit data (in micro-gravity) will be compared with ground test results. These data will be used to help develop improved models to predict damping due to pinned joints. Ground and low-g aircraft testing of this experiment has been completed. This paper describes the experiment and presents results of both ground and low-g aircraft tests which demonstrate that damping of the truss is dramatically influenced by gravity.
Jan, Shau-Shiun; Hsu, Li-Ta; Tsai, Wen-Ming
2010-01-01
In order to provide the seamless navigation and positioning services for indoor environments, an indoor location based service (LBS) test bed is developed to integrate the indoor positioning system and the indoor three-dimensional (3D) geographic information system (GIS). A wireless sensor network (WSN) is used in the developed indoor positioning system. Considering the power consumption, in this paper the ZigBee radio is used as the wireless protocol, and the received signal strength (RSS) fingerprinting positioning method is applied as the primary indoor positioning algorithm. The matching processes of the user location include the nearest neighbor (NN) algorithm, the K-weighted nearest neighbors (KWNN) algorithm, and the probabilistic approach. To enhance the positioning accuracy for the dynamic user, the particle filter is used to improve the positioning performance. As part of this research, a 3D indoor GIS is developed to be used with the indoor positioning system. This involved using the computer-aided design (CAD) software and the virtual reality markup language (VRML) to implement a prototype indoor LBS test bed. Thus, a rapid and practical procedure for constructing a 3D indoor GIS is proposed, and this GIS is easy to update and maintenance for users. The building of the Department of Aeronautics and Astronautics at National Cheng Kung University in Taiwan is used as an example to assess the performance of various algorithms for the indoor positioning system.
Jan, Shau-Shiun; Hsu, Li-Ta; Tsai, Wen-Ming
2010-01-01
In order to provide the seamless navigation and positioning services for indoor environments, an indoor location based service (LBS) test bed is developed to integrate the indoor positioning system and the indoor three-dimensional (3D) geographic information system (GIS). A wireless sensor network (WSN) is used in the developed indoor positioning system. Considering the power consumption, in this paper the ZigBee radio is used as the wireless protocol, and the received signal strength (RSS) fingerprinting positioning method is applied as the primary indoor positioning algorithm. The matching processes of the user location include the nearest neighbor (NN) algorithm, the K-weighted nearest neighbors (KWNN) algorithm, and the probabilistic approach. To enhance the positioning accuracy for the dynamic user, the particle filter is used to improve the positioning performance. As part of this research, a 3D indoor GIS is developed to be used with the indoor positioning system. This involved using the computer-aided design (CAD) software and the virtual reality markup language (VRML) to implement a prototype indoor LBS test bed. Thus, a rapid and practical procedure for constructing a 3D indoor GIS is proposed, and this GIS is easy to update and maintenance for users. The building of the Department of Aeronautics and Astronautics at National Cheng Kung University in Taiwan is used as an example to assess the performance of various algorithms for the indoor positioning system. PMID:22319282
US EPA Base Study Standard Operating Procedure for Continuous Monitoring of Indoor Air
The procedure described is intended for monitoring continuously and simultaneously, at selected work sites, parameters that are most commonly associated with the quality of indoor environments: the concentrations of carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH), illumination, and noise.
The Tampa Asthmatic Children's Study (TACS) was completed to assess environmental exposures for a group of asthmatic children (n = 9) under the age of six and living in Tampa, Florida. Concentrations of particulate organic species are reported from residential indoor, residential...
Therapeutic Play at Inflatable Playgrounds
ERIC Educational Resources Information Center
Yavorcik, Carin
2009-01-01
The environment at indoor inflatable playgrounds, featuring giant bounce houses and slides, can become an ideal place for children with autism to receive helpful sensations. This is the reasoning behind Sensory Nights hosted by the Autism Society of America and Pump It Up, a national franchise of giant, indoor inflatable playgrounds. The private…
DISSOCIATION OF SULFUR HEXAFLUORIDE TRACER GAS IN THE PRESENCE OF AN INDOOR COMBUSTION SOURCE
As an odorless, non-toxic, and inert compound, sulfur hexafluoride (SF6) is one of the most widely used tracer gases in indoor air quality studies in both controlled and uncontrolled environments. This compound may be subject to hydrolysis under elevated temperature to form acidi...
The report summarizes information from the first two phases of a five-phase cooperative effort between research Triangle Institute and the Indoor Environment Management Branch of the U.S. Environmental Protection Agency's Air Pollution Prevention and Control Division to apply pol...
The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.
Overdamping by weakly coupled environments
NASA Astrophysics Data System (ADS)
Esposito, Massimiliano; Haake, Fritz
2005-12-01
A quantum system weakly interacting with a fast environment usually undergoes a relaxation with complex frequencies whose imaginary parts are damping rates quadratic in the coupling to the environment in accord with Fermi’s “golden rule.” We show for various models (spin damped by harmonic-oscillator or random-matrix baths, quantum diffusion, and quantum Brownian motion) that upon increasing the coupling up to a critical value still small enough to allow for weak-coupling Markovian master equations, a different relaxation regime can occur. In that regime, complex frequencies lose their real parts such that the process becomes overdamped. Our results call into question the standard belief that overdamping is exclusively a strong coupling feature.
Sassani, Farrokh
2014-01-01
The simulation results for electromagnetic energy harvesters (EMEHs) under broad band stationary Gaussian random excitations indicate the importance of both a high transformation factor and a high mechanical quality factor to achieve favourable mean power, mean square load voltage, and output spectral density. The optimum load is different for random vibrations and for sinusoidal vibration. Reducing the total damping ratio under band-limited random excitation yields a higher mean square load voltage. Reduced bandwidth resulting from decreased mechanical damping can be compensated by increasing the electrical damping (transformation factor) leading to a higher mean square load voltage and power. Nonlinear EMEHs with a Duffing spring and with linear plus cubic damping are modeled using the method of statistical linearization. These nonlinear EMEHs exhibit approximately linear behaviour under low levels of broadband stationary Gaussian random vibration; however, at higher levels of such excitation the central (resonant) frequency of the spectral density of the output voltage shifts due to the increased nonlinear stiffness and the bandwidth broadens slightly. Nonlinear EMEHs exhibit lower maximum output voltage and central frequency of the spectral density with nonlinear damping compared to linear damping. Stronger nonlinear damping yields broader bandwidths at stable resonant frequency. PMID:24605063
A microclimate study on hypogea environments of ancient roman building.
Scatigno, C; Gaudenzi, S; Sammartino, M P; Visco, G
2016-10-01
Roman hypogea, vernacular settlements or crypts, are underground places characterised by specific and unique challenges (RH<90% and almost constant temperature throughout the whole year) related to their relative isolation from the outdoor environment. These sites often require adequate monitoring tools providing complete environmental information in order to carry out appropriate strategies for scheduling routine maintenance and designing suitable layouts for their preservation. In this work we present the results of a carefully planned thermo-hygrometric monitoring campaign conducted in a peculiar Roman building (130CE), the "Casa di Diana" Mithraeum, sited in Ostia Antica (archaeological site, Rome-Italy), with the aim of characterising the indoor environment as the structure suffers of several conservation problems (biocolonisation, efflorescences, evaporating and condensing cycle for wall-building materials). The campaign involving multipoint continuous measurement was carefully planned to better describe this micro-clime. In addition to underground environmental data available in literature, we have also performed, as a checkpoint control, a thermo-hygrometric monitoring campaign in the "Terme di Mitra" Hypogeum, a few meters from the "Casa di Diana". The recorded data was analysed by multivariate statistical and chemometric analyses. The results brought to light the presence of different microclimates (three areas) within a single Mithraeum: a room (pre-Mithraeum) and an area (Mithraeum: 2-4m) present a thermo-hygrometric environmental behaviour in accordance with a semi-confined environment, another area (Mithraeum: 1-2m) behaves accordingly with underground environments (although it cannot be described as such), and the last area (Mithraeum: 0-1m) where was recording RH values close to saturation (96-99%), associated with non-ventilated areas where the rising damp is "held" and not dispersed, describing an own micro-clime, comparable to a "small greenhouse". This study has allowed to identify some critical areas in view of planning future conservation solutions, without exporting the artefacts kept inside. Copyright © 2016 Elsevier B.V. All rights reserved.
Indoor air quality of houses located in the urban environment of Agra, India.
Taneja, Ajay; Saini, Renuka; Masih, Amit
2008-10-01
Increased concern over the adverse health effects of air pollution has highlighted the need for air-pollution measurements, especially in urban areas, where many sources of air pollutants are normally monitored outdoors as part of obligations under the National Air Quality Strategies. Very little is known about air pollution indoors. In fact, the largest exposure to health-damaging indoor pollution probably occurs in the developing world, not in households, schools, and offices of developed countries where most research and control efforts have been focused to date. As a result much of the health impacts from air pollution worldwide seem to occur among the poorest and most vulnerable populations. The authors in their earlier studies have confirmed the importance of ambient air in determining the quality of air indoors. In this study an observation of air quality indoors and outdoors of domestic homes located in an urban environment from October 2004 to December 2005 in Agra, north central India, is performed. The purpose of this study was to characterize the indoor/outdoor (I/O) relationship of airborne pollutants and recognize their probable source in all three seasons, that is, winter, summer, and rainy season. Concentrations of SO(2), NO(2), CO(2), Cl(2), H(2)S, NH(3), RSPM, and PAH were monitored simultaneously and I/O ratios were calculated. In order to investigate the effect of seasonality on indoor and ambient air quality, winter to summer and winter to monsoon average ratios were calculated. It is apparent that there is a general pattern of increasing levels from monsoon to summer to winter, and similarly from outdoor to indoor air. Regressions analysis had been done to further investigate the influence of outdoor air-pollutant concentrations on indoor concentrations. The most probable categories of sources for these pollutants have been identified by using principal-component analysis. Indoor air pollution is a complex function of energy housing and behavioral factors. On the basis of this study and observations, some interventions are also suggested.
Experimental studies of tuned particle damper: Design and characterization
NASA Astrophysics Data System (ADS)
Zhang, Kai; Xi, Yanhui; Chen, Tianning; Ma, Zhihao
2018-01-01
To better suppress the structural vibration in the micro vibration and harsh environment, a new type of damper, tuned particle damper (TPD), was designed by combining the advantage of classical dynamic vibration absorber (DVA) and particle damper (PD). An equivalent theoretical model was established to describe the dynamic behavior of a cantilever system treated with TPD. By means of a series of sine sweep tests, the dynamic characteristic of TPD under different excitation intensity was explored and the damping performance of TPD was investigated by comparing with classical DVA and PD with the same mass ratio. Experimental results show that with the increasing of excitation intensity TPD shows two different dynamic characteristics successively, i.e., PD-like and DVA-like. TPD shows a wider suppression frequency band than classical DVA and better practicability than PD in the micro vibration environment. Moreover, to characterize the dynamic characteristic of TPD, a simple evaluation of the equivalent dynamic mass and equivalent dynamic damping of the cantilever system treated with TPD was performed by fitting the experimental data to the presented theoretical model. Finally, based on the rheology behaviors of damping particles reported by the previous research results, an approximate phase diagram which shows the motion states of damping particles in TPD was employed to analyze the dynamic characteristic of TPD and several motion states of damping particles in TPD were presented via a high-speed camera.
Walls talk: Microbial biogeography of homes spanning urbanization
Ruiz-Calderon, Jean F.; Cavallin, Humberto; Song, Se Jin; Novoselac, Atila; Pericchi, Luis R.; Hernandez, Jean N.; Rios, Rafael; Branch, Oralee H.; Pereira, Henrique; Paulino, Luciana C.; Blaser, Martin J.; Knight, Rob; Dominguez-Bello, Maria G.
2016-01-01
Westernization has propelled changes in urbanization and architecture, altering our exposure to the outdoor environment from that experienced during most of human evolution. These changes might affect the developmental exposure of infants to bacteria, immune development, and human microbiome diversity. Contemporary urban humans spend most of their time indoors, and little is known about the microbes associated with different designs of the built environment and their interaction with the human immune system. This study addresses the associations between architectural design and the microbial biogeography of households across a gradient of urbanization in South America. Urbanization was associated with households’ increased isolation from outdoor environments, with additional indoor space isolation by walls. Microbes from house walls and floors segregate by location, and urban indoor walls contain human bacterial markers of space use. Urbanized spaces uniquely increase the content of human-associated microbes—which could increase transmission of potential pathogens—and decrease exposure to the environmental microbes with which humans have coevolved. PMID:26933683
Active member vibration control experiment in a KC-135 reduced gravity environment
NASA Technical Reports Server (NTRS)
Lawrence, C. R.; Lurie, B. J.; Chen, G.-S.; Swanson, A. D.
1991-01-01
An active member vibration control experiment in a KC-135 reduced gravity environment was carried out by the Air Force Flight Dynamics Laboratory and the Jet Propulsion Laboratory. Two active members, consisting of piezoelectric actuators, displacement sensors, and load cells, were incorporated into a 12-meter, 104 kg box-type test structure. The active member control design involved the use of bridge (compound) feedback concept, in which the collocated force and velocity signals are feedback locally. An impact-type test was designed to accommodate the extremely short duration of the reduced gravity testing window in each parabolic flight. The moving block analysis technique was used to estimate the modal frequencies and dampings from the free-decay responses. A broadband damping performance was demonstrated up to the ninth mode of 40 Hz. The best damping performance achieved in the flight test was about 5 percent in the fourth mode of the test structure.
Real-time localization of mobile device by filtering method for sensor fusion
NASA Astrophysics Data System (ADS)
Fuse, Takashi; Nagara, Keita
2017-06-01
Most of the applications with mobile devices require self-localization of the devices. GPS cannot be used in indoor environment, the positions of mobile devices are estimated autonomously by using IMU. Since the self-localization is based on IMU of low accuracy, and then the self-localization in indoor environment is still challenging. The selflocalization method using images have been developed, and the accuracy of the method is increasing. This paper develops the self-localization method without GPS in indoor environment by integrating sensors, such as IMU and cameras, on mobile devices simultaneously. The proposed method consists of observations, forecasting and filtering. The position and velocity of the mobile device are defined as a state vector. In the self-localization, observations correspond to observation data from IMU and camera (observation vector), forecasting to mobile device moving model (system model) and filtering to tracking method by inertial surveying and coplanarity condition and inverse depth model (observation model). Positions of a mobile device being tracked are estimated by system model (forecasting step), which are assumed as linearly moving model. Then estimated positions are optimized referring to the new observation data based on likelihood (filtering step). The optimization at filtering step corresponds to estimation of the maximum a posterior probability. Particle filter are utilized for the calculation through forecasting and filtering steps. The proposed method is applied to data acquired by mobile devices in indoor environment. Through the experiments, the high performance of the method is confirmed.
Wang, Yu-Hao; Su, Hsing-Hao; Hsu, Lan; Wang, Chung-Yang; Wu, Pi-Hsiung
2018-01-01
With a global rising trend in prevalence of allergic diseases, more attention has been paid to investigation of environmental risk factors. Many risk factors have so far been identified. However, novel risk factors specific to Taiwanese environment and lifestyle were still relatively unknown. To investigate the potential effects of a number of little-known indoor risk factors on the frequency of doctor's visit for respiratory problems in context of Taiwanese environment and lifestyle. A cross-sectional, population-based study was performed on a 861 participants around Kaohsiung area, Taiwan. Survey investigation was employed to assess the household environment and the frequency of doctor's visit for respiratory problems. Participants who performed "daily cleaning" was shown to have a significantly (p=0.007) higher mean number of doctor's visits in comparison to those who did not. Similar observation was made for participants who periodically took out beddings (p=0.042). Age had a significant positive correlation (linear regression β 0.089) with frequency of respiratory problems. The habit of daily cleaning was implicated as a potential indoor risk factor due to the unique nature of Taiwanese cleaning habit and close contact with cleaning supplies, which could serve as chemical irritants. Bedding takeout was predicted to be an indicator of chronic allergies rather than an actual risk factor. However, both were controversial in their role as potential indoor risk factor, and required further examination.
Children's exposure to brominated flame retardants in indoor environments - A review.
Malliari, Eleftheria; Kalantzi, Olga-Ioanna
2017-11-01
The aim of this review is to present up-to-date research on children's exposure to brominated flame retardants (BFRs) in indoor environments. Large geographical variations were observed for all BFRs [polybrominated diphenyl ethers (PBDEs), hexabromocyclododecane (HBCDD), tetrabromobisphenol A (TBBPA)], with the highest concentrations of PBDEs measured in North America (BDE-47) and Europe (BDE-209), where higher concentrations of PBDEs are present in dust from houses, daycare centers and primary schools. In Asia the highest PBDE concentrations were measured in China, near e-waste recycling areas. In the Middle East, Australia and Africa BFR levels were low in most indoor spaces. Asian countries also have the highest concentrations of TBBPA and HBCDD, followed by European countries. Fewer studies have been conducted measuring novel and emerging BFRs (NBFRs or EBFRs), of which decabromodiphenylethane (DBDPE) has the highest concentration in indoor environments, especially in China. The vast majority of children's exposure studies have been conducted in houses, sampling either dust or air, and considerably fewer in schools, daycare centers, cars and public facilities, despite BFR levels being comparable to (or sometimes even higher than) house dust. Relatively fewer studies focused on children's tissues such as serum, and only two studied exposure via mouthing toys. Alternative noninvasive sampling matrices that may act as surrogates for exposure to BFRs such as handwipes and silicone wristbands have recently started to gain momentum, because of the ease of sampling, faster collection time and better correlations to serum than house dust. Feces sampling is another promising alternative to children's serum that warrants further research. While many studies have associated different indoor environment characteristics, there is a knowledge gap on the association between children's behaviour and activity patterns and their exposure to BFRs, as well as data on infant exposure to BFRs via baby products. Results from the studies showed that dust ingestion was the dominant exposure pathway for most studied BFRs compared to indoor air inhalation and dermal contact, especially for infants and toddlers who have higher exposures than older children. Copyright © 2017 Elsevier Ltd. All rights reserved.
Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju
2014-01-01
A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated. PMID:24662407
HyMoTrack: A Mobile AR Navigation System for Complex Indoor Environments.
Gerstweiler, Georg; Vonach, Emanuel; Kaufmann, Hannes
2015-12-24
Navigating in unknown big indoor environments with static 2D maps is a challenge, especially when time is a critical factor. In order to provide a mobile assistant, capable of supporting people while navigating in indoor locations, an accurate and reliable localization system is required in almost every corner of the building. We present a solution to this problem through a hybrid tracking system specifically designed for complex indoor spaces, which runs on mobile devices like smartphones or tablets. The developed algorithm only uses the available sensors built into standard mobile devices, especially the inertial sensors and the RGB camera. The combination of multiple optical tracking technologies, such as 2D natural features and features of more complex three-dimensional structures guarantees the robustness of the system. All processing is done locally and no network connection is needed. State-of-the-art indoor tracking approaches use mainly radio-frequency signals like Wi-Fi or Bluetooth for localizing a user. In contrast to these approaches, the main advantage of the developed system is the capability of delivering a continuous 3D position and orientation of the mobile device with centimeter accuracy. This makes it usable for localization and 3D augmentation purposes, e.g. navigation tasks or location-based information visualization.
Leivo, Virpi; Prasauskas, Tadas; Du, Liuliu; Turunen, Mari; Kiviste, Mihkel; Aaltonen, Anu; Martuzevicius, Dainius; Haverinen-Shaughnessy, Ulla
2018-04-15
Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO 2 ) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO 2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO 2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use. Copyright © 2017 Elsevier B.V. All rights reserved.
HyMoTrack: A Mobile AR Navigation System for Complex Indoor Environments
Gerstweiler, Georg; Vonach, Emanuel; Kaufmann, Hannes
2015-01-01
Navigating in unknown big indoor environments with static 2D maps is a challenge, especially when time is a critical factor. In order to provide a mobile assistant, capable of supporting people while navigating in indoor locations, an accurate and reliable localization system is required in almost every corner of the building. We present a solution to this problem through a hybrid tracking system specifically designed for complex indoor spaces, which runs on mobile devices like smartphones or tablets. The developed algorithm only uses the available sensors built into standard mobile devices, especially the inertial sensors and the RGB camera. The combination of multiple optical tracking technologies, such as 2D natural features and features of more complex three-dimensional structures guarantees the robustness of the system. All processing is done locally and no network connection is needed. State-of-the-art indoor tracking approaches use mainly radio-frequency signals like Wi-Fi or Bluetooth for localizing a user. In contrast to these approaches, the main advantage of the developed system is the capability of delivering a continuous 3D position and orientation of the mobile device with centimeter accuracy. This makes it usable for localization and 3D augmentation purposes, e.g. navigation tasks or location-based information visualization. PMID:26712755
Effects of Indoor Air Pollutants on Atopic Dermatitis.
Kim, JaKyoung; Kim, HyungJin; Lim, DaeHyun; Lee, Young-Kyu; Kim, Jeong Hee
2016-12-09
The increasing prevalence of atopic dermatitis (AD) is associated with variations in indoor environments. In Korea, many inner walls of homes are covered with wallpaper: such walls emit indoor air pollutants, including volatile organic compounds (VOCs) and formaldehyde. This randomized, double-blind study investigated the effects of wallpaper on indoor air quality and AD. Thirty-one children (aged three to eight years) with moderate AD were assigned to environmentally-friendly (EF) and polyvinyl chloride (PVC) wallpaper groups. Indoor air concentrations of VOCs, natural VOCs (NVOCs), formaldehyde, and total suspended bacteria were measured before and two (W₂) and eight weeks (W₈) after wallpapering. Scoring Atopic Dermatitis (SCORAD) evaluations and blood tests were performed during the same period. The EF wallpaper and PVC wallpaper groups showed similar trends in the changes in total VOCs (TVOC) and formaldehyde content in the indoor air. However, the EF wallpaper group showed more improvement on the SCORAD at W₂ and W₈ than the PVC wallpaper group. The SCORAD index was positively correlated with several indoor air pollutants. Further, the SCORAD index and NVOC % were negatively correlated. Improved SCORAD index and effects of wallpapering on indoor air quality improvements occurred within a short period of time in both groups. We believe that NVOCs in indoor air after EF wallpapering have a beneficial effect on health.
Airway toxicity of house dust and its fungal composition.
Piecková, Elena; Wilkins, Ken
2004-01-01
House dust is an important source of different toxic metabolites as well as allergens, including those of fungal origin, in the indoor environment. A bio-assay employing 1-day-old chick tracheas was used to characterize airway effects of 2-butanone and dimethylsulphoxide (Me2SO) extracts of 23 dust samples collected from water damaged (13) and control (10) Danish schools. Direct microscopical analysis of samples, followed by cultivation on dichloran 18 % glycerol agar at 25 degrees C for 10 days to establish their mycoflora, was performed. The in vitro ciliostatic potential of the chloroform-extractable endo- and exometabolites of 41 representative fungal isolates was determined. Nine dust extracts in 2-butanone (2 from damp rooms) or 10 (6) in Me(2)SO showed some ciliostatic activity in the 3-days' experiment. Fungal composition of dust from buildings with leakage was almost identical with that from undamaged houses, as well as the fungal colony counts from the damp schools and the control samples. Aspergillus spp. were prevalent in the samples - 31 or 40 % of all fungi, followed by Penicillium spp. and Cladosporium cladosporioides. Alternaria spp., Chaetomium spp., Mucor spp., Mycelia sterilia, Paecilomyces variotii, Rhizopus sp., Ulocladium sp. and yeasts were each isolated in less than 8 % of the fungal content. No Aspergillus flavus isolate (8 in total) was aflatoxigenic,em>in vitro. Alternaria spp., Aspergillus spp., Botrytis cinerea, Penicillium spp., C. cladosporioides, Chaetomium spp. and Ulocladium sp.; in total, 88 % of all fungi tested, produced ciliostatically active metabolites. These toxigenic strains were also present in 4 dust samples from controls and 5 dust samples from water damaged buildings. Extracts of these dust samples were also toxic in bioassay. There were bio-detectable concentrations (10-20 microg of extracts/ml of the organ culture medium) of toxic compounds in house dust. Contribution of fungal metabolites to its toxic effect should be studied further.
Foliage Plants for Improving Indoor Air Quality
NASA Technical Reports Server (NTRS)
Wolverton, B. C.
1988-01-01
NASA's research with foliage houseplants during the past 10 years has produced a new concept in indoor air quality improvement. This new and exciting technology is quite simple. Both plant leaves and roots are utilized in removing trace levels of toxic vapors from inside tightly sealed buildings. Low levels of chemicals such as carbon monoxide and formaldehyde can be removed from indoor environments by plant leaves alone, while higher concentrations of numerous toxic chemicals can be removed by filtering indoor air through the plant roots surrounded by activated carbon. The activated carbon absorbs large quantities of the toxic chemicals and retains them until the plant roots and associated microorganisms degrade and assimilate these chemicals.
A proposed UAV for indoor patient care.
Todd, Catherine; Watfa, Mohamed; El Mouden, Yassine; Sahir, Sana; Ali, Afrah; Niavarani, Ali; Lutfi, Aoun; Copiaco, Abigail; Agarwal, Vaibhavi; Afsari, Kiyan; Johnathon, Chris; Okafor, Onyeka; Ayad, Marina
2015-09-10
Indoor flight, obstacle avoidance and client-server communication of an Unmanned Aerial Vehicle (UAV) raises several unique research challenges. This paper examines current methods and associated technologies adapted within the literature toward autonomous UAV flight, for consideration in a proposed system for indoor healthcare administration with a quadcopter. We introduce Healthbuddy, a unique research initiative towards overcoming challenges associated with indoor navigation, collision detection and avoidance, stability, wireless drone-server communications and automated decision support for patient care in a GPS-denied environment. To address the identified research deficits, a drone-based solution is presented. The solution is preliminary as we develop and refine the suggested algorithms and hardware system to achieve the research objectives.
Study of indoor radon distribution using measurements and CFD modeling.
Chauhan, Neetika; Chauhan, R P; Joshi, M; Agarwal, T K; Aggarwal, Praveen; Sahoo, B K
2014-10-01
Measurement and/or prediction of indoor radon ((222)Rn) concentration are important due to the impact of radon on indoor air quality and consequent inhalation hazard. In recent times, computational fluid dynamics (CFD) based modeling has become the cost effective replacement of experimental methods for the prediction and visualization of indoor pollutant distribution. The aim of this study is to implement CFD based modeling for studying indoor radon gas distribution. This study focuses on comparison of experimentally measured and CFD modeling predicted spatial distribution of radon concentration for a model test room. The key inputs for simulation viz. radon exhalation rate and ventilation rate were measured as a part of this study. Validation experiments were performed by measuring radon concentration at different locations of test room using active (continuous radon monitor) and passive (pin-hole dosimeters) techniques. Modeling predictions have been found to be reasonably matching with the measurement results. The validated model can be used to understand and study factors affecting indoor radon distribution for more realistic indoor environment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Fuselli, Sergio; De Felice, Marco; Morlino, Roberta; Turrio-Baldassarri, Luigi
2010-01-01
Fourteen volatile organic compounds (VOCs)—twelve hydrocarbons and two organochlorine compounds—were monitored both outdoors and indoors for three years at one site in Rome. Results showed that 118 out of 168 indoor seasonal mean values were higher than the corresponding outdoor concentrations. The most relevant source of outdoor hydrocarbons was automotive exhaust emissions. Due to the enforcement of various measures to protect health and the environment, outdoor levels of monoaromatic hydrocarbons decreased about ten fold over 15 years, and aliphatic hydrocarbons also decreased. With the decrease in these outdoor concentrations, indoor air sources are likely to be more relevant for indoor air exposures. Winter outdoor values for monoaromatic hydrocarbons were generally markedly higher than the summer ones. The gradual replacement of the current fleet of circulating cars with new cars complying with EURO 5 standards, further reducing hydrocarbon emissions, may possibly lead to an increase in the observed indoor/outdoor ratios. It is indeed more difficult to remove indoor sources, some of which are still unknown. PMID:21139860
Fluid oscillation in the Drop Tower
NASA Technical Reports Server (NTRS)
Kaukler, William F.
1988-01-01
An interfluid meniscus oscillates within a cylindrical container when suddenly released from earth's gravity and taken into a microgravity environment. Oscillations damp out from energy dissipative mechanisms such as viscosity and interfacial friction. Damping out of the oscillations by the latter mechanism is affected by the nature of the interfacial junction between the fluid-fluid interface and the container wall. Perfluoromethylcyclohexane and isopropanol in glass were the materials used for the experiment. The wetting condition of the fluids against the wall changes at the critical wetting transition temperature. This change in wetting causes a change in the damping characteristics.
ASHRAE and residential ventilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.
In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality createsmore » health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the logical place to provide leadership. This leadership has been demonstrated most recently by the publication of the first nationally recognized standard on ventilation in homes, ASHRAE Standard 62.2-2003, which builds on work that has been part of ASHRAE for many years and will presumably continue. Homeowners and occupants, which includes virtually all of us, will benefit from the application of Standard 62.2 and use of the top ten list. This activity is exactly the kind of benefit to society that the founders of ASHRAE envisioned and is consistent with ASHRAE's mission and vision. ASHRAE members should be proud of their Society for taking leadership in residential ventilation.« less
Shen, Huazhen; Tsai, Cheng-Mou; Yuan, Chung-Shin; Jen, Yi-Hsiu; Ie, Iau-Ren
2017-01-01
This study firstly investigated the species, concentration variation, and emission factors of mercury emitted from the burning of incenses and joss papers in an Asian temple. Both indoor and outdoor speciated mercury (GEM, GOM, and PHg) were sampled by manual samplers, while ambient GEM at an indoor site was in-situ monitored by a continuous GEM monitor. Field measurement results showed that the total atmospheric mercury (TAM) concentrations in indoor and outdoor environments were in the range of 8.03-35.72 and 6.03-31.35 ng/m 3 , respectively. The indoor and outdoor ratios (I/O) of TAM in the daytime and at nighttime were in the range of 0.64-0.90 and 1.50-2.04, respectively. The concentrations of GEM, GOM, and PHg during the holiday periods were approximately 1-4 times higher than those during the non-holiday periods. GEM was the dominant mercury species in the indoor and outdoor environments and accounted for 63-81% of TAM, while the oxidized mercury accounted for 19-37% of TAM. Burning incenses and joss papers in a combustion chamber showed that the concentration of GEM from joss paper burning ranged from 4.07 to 11.62 μg/m 3 , or about 13.97 times higher than that of incense burning, while the concentration of PHg from incense burning ranged from 95.91 to 135.07 ng/m 3 , or about 3.29 times higher than that of joss paper burning. The emission factors of incense burning were 10.39 ng/g of GEM and 1.40 ng/g of PHg, while those of joss paper burning were 12.65 ng/g of GEM and 1.27 ng/g of PHg, respectively. This study revealed that speciated mercury emitted from worship activities had significant influence on the indoor and outdoor mercury concentrations in an Asian temple. Higher intensity of worship activities during holidays resulted in a higher concentration of speciated mercury in indoor and outdoor air, which might cause health threats to worshipers, staffs, and surrounding inhabitants through long-term exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.
Indoor air humidity, air quality, and health - An overview.
Wolkoff, Peder
2018-04-01
There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture-damage of the building construction and emissions therefrom. Further, residential versus public environments should be considered as separate entities with different characteristics and demands of humidity. Research is needed about particle, bacteria and virus dynamics indoors for improvement of quality of life and with more focus on the impact of absolute humidity. "Dry (or wet) air" should be redefined to become a meaningful IAQ descriptor. Copyright © 2018 The Author. Published by Elsevier GmbH.. All rights reserved.
Indoor and outdoor elemental mercury: a comparison of three different cases.
Loupa, G; Polyzou, C; Zarogianni, A M; Ouzounis, K; Rapsomanikis, S
2017-02-01
Gaseous elemental mercury (GEM) concentrations were determined in three different indoor environments: an office in a building with no indoor sources of mercury (Bldg. I), an office affected by indoor mercury emissions from an adjacent laboratory (Bldg. II), and finally, an office where an outdoor mercury spill occurred accidentally (Bldg. III). The maximum recorded indoor GEM concentrations, with the largest variation in time, were observed in Bldg. II, with a continuous indoor mercury source (lower to upper quartile 15 to 62 ng m -3 ). The lowest values were recorded in Bldg. I (lower to upper quartile 3 to 5 ng m -3 ), where indoor GEM levels were affected mainly by the exhaust of vehicles in the parking lot of the building. The monitoring of GEM indoors (lower to upper quartile 15 to 42 ng m -3 ), and outdoors (in several heights) of the Bldg. III, revealed that the cleaning up procedure that followed the spill was not adequate. Auxiliary measurements in the first two cases were the indoor microclimatic conditions, as well as the indoor CO 2 concentrations, and in the third case the outdoor meteorological data. The exhaust of vehicles, the chemical reagents, and an outdoor mercury spill were found to mainly affect the observed indoor GEM levels. People in Bldg. II and people walking through the area, where Hg 0 was spilled, were found to be exposed to concentrations above some guide values.
Chen, She-Jun; Ding, Nan; Zhu, Zhi-Cheng; Tian, Mi; Luo, Xiao-Jun; Mai, Bi-Xian
2014-11-01
Halogenated flame retardants (HFRs) are a class of ubiquitous pollutants in the environment and attract increasing attention. In the present study, HFR concentrations were measured in indoor and outdoor dust in an important industrial city (Dongguan) in southern China, in which their presence and associated human exposure are unknown. The HFRs were dominated by polybrominated diphenyl ethers (PBDEs) and decabromodiphenyl ethane (DBDPE), with mean concentrations of 2365 and 2441 ng/g in the indoor dust, respectively, which were 2-3 order of magnitude higher the concentrations of other HFRs. However elevated tri- to hepta-BDE concentrations (869 ng/g) were found in Houjie Town, a furniture manufacturing center. The mean indoor/outdoor (I/O) ratios of HFR concentrations in the dust were all larger than one (1.55-16.4), suggesting the importance of indoors sources for HFRs in indoor dust in this industrial city. Principal component analysis (PCA) showed that the correlations among the HFRs in the indoor dust probably revealed differences in their commercial applications, while most HFRs in the outdoor dust have similar sources except for phased-out BDE47 and 99. The compositions of lower brominated PBDEs varied among the towns, probably due to their different sources or influence of photo-degradation. Nevertheless, the similar composition of highly brominated congeners indicated little photo-degradation encountered in the ambient environment. The non-cancer risk associated with indoor dust ingestion is low for the general population in Dongguan, but some children in the furniture manufacturing center have significantly high risk of exposure to banned PBDEs. Copyright © 2014 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Harvey, Nigel; Reimers, Stian
2013-01-01
People's forecasts from time series underestimate future values for upward trends and overestimate them for downward ones. This trend damping may occur because (a) people anchor on the last data point and make insufficient adjustment to take the trend into account, (b) they adjust toward the average of the trends they have encountered within the…
Effects of radiation and creep on viscoelastic damping materials
NASA Astrophysics Data System (ADS)
Henderson, John P.; Lewis, Tom M.; Murrell, Fred H.; Mangra, Danny
1995-05-01
The Advanced Photon Source (APS), under construction at Argonne National Laboratory (ANL), requires precise alignment of several large magnets. Submicron vibratory displacements of the magnets can degrade the performance of this important facility. Viscoelastic materials (VEM) have been shown to be effective in the control of the vibration of these magnets. Damping pads, placed under the magnet support structures in the APS storage ring, use thin layers of VEM. These soft VEM layers are subject to both high-energy radiation environment and continuous through-the-thickness compressive loads. Material experiments were conducted to answer concerns over the long term effects of the radiation environment and creep in the viscoelastic damping layers. The effects of exposure to radiation as high as 108 rad on the complex modulus were measured. Through-the-thickness creep displacements of VEM thin layers subjected to static loads of 50 psi were measured. Creep tests were conducted at elevated temperatures. Time-temperature equivalence principles were used to project creep displacements at room temperatures over several years. These damping material measurements should be of interest to vibration control engineers working with a variety of applications of fields ranging from aerospace to industrial machinery.
Noisy oscillator: Random mass and random damping.
Burov, Stanislav; Gitterman, Moshe
2016-11-01
The problem of a linear damped noisy oscillator is treated in the presence of two multiplicative sources of noise which imply a random mass and random damping. The additive noise and the noise in the damping are responsible for an influx of energy to the oscillator and its dissipation to the surrounding environment. A random mass implies that the surrounding molecules not only collide with the oscillator but may also adhere to it, thereby changing its mass. We present general formulas for the first two moments and address the question of mean and energetic stabilities. The phenomenon of stochastic resonance, i.e., the expansion due to the noise of a system response to an external periodic signal, is considered for separate and joint action of two sources of noise and their characteristics.
Vapor intrusion refers to the situation in which harmful chemicals [such as halogenated or chlorinated volatile organic compounds (VOC) or petroleum products] in the groundwater or soil volatilize in the vadose zone and migrate into the indoor environment. These chemicals typical...
This paper describes a method for dynamic modeling of the interactions of semivolatile organic compounds (SVOCs) with airborne and settled particulate matter in the indoor environment. This method is fully compatible with the other components within the framework. Despite the unc...
Preschool Teachers' Views on Schools' Indoor and Outdoor Environment Safety
ERIC Educational Resources Information Center
Konakli, Tugba; Ülçetin, Esra
2016-01-01
The aim of this research is to analyze opinions of teachers who work in preschool education institutions concerning precautions that should be taken for indoor and outdoor security. Study group of this research is determined by criterion sampling from purposeful sampling techniques. The study group of this research is consist of eight preschool…
Compact fluorescent light (CFL) bulbs contain a few milligrams (mg) of elemental mercury. When a CFL breaks, some of the mercury is immediately released as elemental mercury vapor and the remainder is deposited on indoor surfaces with the bulb debris. In a controlled study design...
Strategies to reduce indoor exposures to certain toxic air contaminants suggested a study of the penetration of these toxics from the external atmosphere into an unoccupied research house. The mass balance method is applied to measure rates of sorption and re-emission of the con...
WLAN Positioning Methods and Supporting Learning Technologies for Mobile Platforms
ERIC Educational Resources Information Center
Melkonyan, Arsen
2013-01-01
Location technologies constitute an essential component of systems design for autonomous operations and control. The Global Positioning System (GPS) works well in outdoor areas, but the satellite signals are not strong enough to penetrate inside most indoor environments. As a result, a new strain of indoor positioning technologies that make use of…
This research is a combination of experimental results and analysis of formaldehyde penetration across a residential building envelope with the objective of developing an understanding of the factors that govern indoor air concentrations of air toxics and to provide linkages betw...
Polybrominated diphenyl ethers in indoor air in Kuwait: Implications for human exposure
NASA Astrophysics Data System (ADS)
Gevao, Bondi; Al-Bahloul, Majed; Al-Ghadban, Abdul Nabi; Ali, Lulwa; Al-Omair, Ali; Helaleh, Murad; Al-Matrouk, Khaled; Zafar, Jamal
Polyurethane foam plug passive samplers were used to concurrently measure air concentrations of polybrominated diphenyl ethers (PBDEs) in 70 indoor environments. PBDEs were detected in all homes and offices investigated with patterns similar to the distribution in the commercial penta technical formulation (Bromkal 70-5DE). The ubiquitous distribution of these compounds in indoor environments may be due to the volatilization of these chemicals from foam (e.g. mattresses, foam padded furniture), electronic equipments (e.g. TVs, printers, computers) and other consumer products to which they are added as flame retardants. Mean ΣPBDEs concentration in air was log-normally distributed and ranged from ˜2-385 pg m -3. Using an inhalation rate of 8 and 20 m 3 day -1 for children and adults respectively, exposure via inhalation is estimated to be 173 and 399 pg day -1 for children and adults respectively. This study supports the growing body of evidence for the ubiquitous presence of these compounds in indoor air and the potential for continuous, low-level exposure both at work and home.
Exoskeletons and economics: indoor arthropod diversity increases in affluent neighbourhoods.
Leong, Misha; Bertone, Matthew A; Bayless, Keith M; Dunn, Robert R; Trautwein, Michelle D
2016-08-01
In urban ecosystems, socioeconomics contribute to patterns of biodiversity. The 'luxury effect', in which wealthier neighbourhoods are more biologically diverse, has been observed for plants, birds, bats and lizards. Here, we used data from a survey of indoor arthropod diversity (defined throughout as family-level richness) from 50 urban houses and found that house size, surrounding vegetation, as well as mean neighbourhood income best predict the number of kinds of arthropods found indoors. Our finding, that homes in wealthier neighbourhoods host higher indoor arthropod diversity (consisting of primarily non-pest species), shows that the luxury effect can extend to the indoor environment. The effect of mean neighbourhood income on indoor arthropod diversity was particularly strong for individual houses that lacked high surrounding vegetation ground cover, suggesting that neighbourhood dynamics can compensate for local choices of homeowners. Our work suggests that the management of neighbourhoods and cities can have effects on biodiversity that can extend from trees and birds all the way to the arthropod life in bedrooms and basements. © 2016 The Authors.
Exoskeletons and economics: indoor arthropod diversity increases in affluent neighbourhoods
Bertone, Matthew A.; Bayless, Keith M.; Dunn, Robert R.; Trautwein, Michelle D.
2016-01-01
In urban ecosystems, socioeconomics contribute to patterns of biodiversity. The ‘luxury effect’, in which wealthier neighbourhoods are more biologically diverse, has been observed for plants, birds, bats and lizards. Here, we used data from a survey of indoor arthropod diversity (defined throughout as family-level richness) from 50 urban houses and found that house size, surrounding vegetation, as well as mean neighbourhood income best predict the number of kinds of arthropods found indoors. Our finding, that homes in wealthier neighbourhoods host higher indoor arthropod diversity (consisting of primarily non-pest species), shows that the luxury effect can extend to the indoor environment. The effect of mean neighbourhood income on indoor arthropod diversity was particularly strong for individual houses that lacked high surrounding vegetation ground cover, suggesting that neighbourhood dynamics can compensate for local choices of homeowners. Our work suggests that the management of neighbourhoods and cities can have effects on biodiversity that can extend from trees and birds all the way to the arthropod life in bedrooms and basements. PMID:27484644
Indoor radio measurement and planning for UMTS/HSDPA with antennas
NASA Astrophysics Data System (ADS)
Eheduru, Marcellinus
Over the last decade, mobile communication networks have evolved tremendously with a key focus on providing high speed data services in addition to voice. The third generation of mobile networks in the form of Universal Mobile Telecommunications System (UMTS) is already offering revolutionary mobile broadband experience to its users by deploying High Speed Downlink Packet Access (HSDPA) as its packet-data technology. With data speeds up to 14.4 Mbps and ubiquitous mobility, HSDPA is anticipated to become a preferred broadband access medium for end-users via mobile phones, laptops etc. While majority of these end-users are located indoors most of the time, approximately 70-80% of the HSDPA traffic is estimated to originate from inside buildings. Thus for network operators, indoor coverage has become a necessity for technical and business reasons. Macro-cellular (outdoor) to indoor coverage is a natural inexpensive way of providing network coverage inside the buildings. However, it does not guarantee sufficient link quality required for optimal HSDPA operation. On the contrary, deploying a dedicated indoor system may be far too expensive from an operator's point of view. In this thesis, the concept is laid for the understanding of indoor radio wave propagation in a campus building environment which could be used to plan and improve outdoor-to-indoor UMTS/HSDPA radio propagation performance. It will be shown that indoor range performance depends not only on the transmit power of an indoor antenna, but also on the product's response to multipath and obstructions in the environment along the radio propagation path. An extensive measurement campaign will be executed in different indoor environments analogous to easy, medium and hard radio conditions. The effects of walls, ceilings, doors and other obstacles on measurement results would be observed. Chapter one gives a brief introduction to the evolution of UMTS and HSDPA. It goes on to talk about radio wave propagation and some important properties of antennas which must be considered when choosing an antenna for indoor radio propagation. The challenges of in-building network coverage and also the objectives of this thesis are also mentioned in this chapter. The evolution and standardization, network architecture, radio features and most importantly, the radio resource management features of UMTS/HSDPA are given in chapter two. In this chapter, the reason why Wideband Code Division Multiple Access (WCDMA) was specified and selected for 3G (UMTS) systems would be seen. The architecture of the radio access network, interfaces with the radio access network between base stations and radio network controllers (RNC), and the interface between the radio access network and the core network are also described in this chapter. The main features of HSDPA are mentioned at the end of the chapter. In chapter three the principles of the WCDMA air interface, including spreading, Rake reception, signal fading, power control and handovers are introduced. The different types and characteristics of the propagation environments and how they influence radio wave propagation are mentioned. UMTS transport, logical and physical channels are also mentioned, highlighting their significance and relationship in and with the network. Radio network planning for UMTS is discussed in chapter four. The outdoor planning process which includes dimensioning, detailed planning, optimization and monitoring is outlined. Indoor radio planning with distributed antenna systems (DAS), which is the idea and motivation behind this thesis work, is also discussed. The various antennas considered and the antenna that was selected for this thesis experiment was discussed in chapter five. The antenna radiation pattern, directivity, gain and input impedance were the properties of the antenna that were taken into consideration. The importance of the choice of the antenna for any particular type of indoor environment is also mentioned. In chapter six, the design and fabrication of the monopole antennas used for the experimental measurement is mentioned. The procedure for measurement and the equipment used are also discussed. The results gotten from the experiment are finally analyzed and discussed. In this chapter the effect of walls, floors, doors, ceilings and other obstacles on radio wave propagation will be seen. Finally, chapter seven concludes this thesis work and gives some directions for future work.
Calibration of LR-115 for 222Rn monitoring taking into account the plateout effect.
Da Silva, A A R; Yoshimura, E M
2003-01-01
The dose received by people exposed to indoor radon is mainly due to radon progeny. This fact points to the establishment of techniques that access either radon and progeny together, or only radon progeny concentration. In this work a low cost and easy to use methodology is presented to determine the total indoor alpha emission concentration. It is based on passive detection using LR-115 and CR-39 detectors, taking into account the plateout effect. A calibration of LR-115 track density response was done by indoor exposure in controlled environments and dwellings, places where 222Rn and progeny concentration were measured with CR-39. The calibration factor obtained showed great dependence on the ambient condition: (0.69 +/- 0.04) cm for controlled environments and (0.43 +/- 0.03) cm for dwellings.
Lidar-based door and stair detection from a mobile robot
NASA Astrophysics Data System (ADS)
Bansal, Mayank; Southall, Ben; Matei, Bogdan; Eledath, Jayan; Sawhney, Harpreet
2010-04-01
We present an on-the-move LIDAR-based object detection system for autonomous and semi-autonomous unmanned vehicle systems. In this paper we make several contributions: (i) we describe an algorithm for real-time detection of objects such as doors and stairs in indoor environments; (ii) we describe efficient data structures and algorithms for processing 3D point clouds acquired by laser scanners in a streaming manner, which minimize the memory copying and access. We show qualitative results demonstrating the effectiveness of our approach on runs in an indoor office environment.
Hubbard, H F; Coleman, B K; Sarwar, G; Corsi, R L
2005-12-01
The use of indoor ozone generators as air purifiers has steadily increased over the past decade. Many ozone generators are marketed to consumers for their ability to eliminate odors and microbial agents and to improve health. In addition to the harmful effects of ozone, recent studies have shown that heterogeneous and homogeneous reactions between ozone and some unsaturated hydrocarbons can be an important source of indoor secondary pollutants, including free radicals, carbonyls, carboxylic acids, and fine particles. Experiments were conducted in one apartment and two detached single-family dwellings in Austin, TX, to assess the effects of an ozone generator on indoor secondary organic aerosol concentrations in actual residential settings. Ozone was generated using a commercial ozone generator marketed as an air purifier, and particle measurements were recorded before, during, and after the release of terpenes from a pine oil-based cleaning product. Particle number concentration, ozone concentration, and air exchange rate were measured during each experiment. Particle number and mass concentrations increased when both terpenes and ozone were present at elevated levels. Experimental results indicate that ozone generators in the presence of terpene sources facilitate the growth of indoor fine particles in residential indoor atmospheres. Human exposure to secondary organic particles can be reduced by minimizing the intentional release of ozone, particularly in the presence of terpene sources. Past studies have shown that ozone-initiated indoor chemistry can lead to elevated concentrations of fine particulate matter, but have generally been completed in controlled laboratory environments and office buildings. We explored the effects of an explicit ozone generator marketed as an air purifier on the formation of secondary organic aerosol mass in actual residential indoor settings. Results indicate significant increases in number and mass concentrations for particles <0.7 microns in diameter, particularly when an ozone generator is used in the presence of a terpene source such as a pine oil-based cleaner. These results add evidence to the potentially harmful effects of ozone generation in residential environments.
Tamerius, JD; Perzanowski, MS; Acosta, LM; Jacobson, JS; Goldstein, IF; Quinn, JW; Rundle, AG; Shaman, J
2013-01-01
Background Numerous mechanisms link outdoor weather and climate conditions to human health. It is likely that many health conditions are more directly affected by indoor rather than outdoor conditions. Yet, the relationship between indoor temperature and humidity conditions to outdoor variability, and the heterogeneity of the relationship among different indoor environments are largely unknown. Methods We use 5–14 day measures of indoor temperature and relative humidity from 327 dwellings in New York City for the years 2008–2011 to investigate the relationship between indoor climate, outdoor meteorological conditions, socioeconomic conditions, and building descriptors. Study households were primarily middle-income and located across the boroughs of Brooklyn, Queens, Bronx, and Manhattan. Results Indoor temperatures are positively associated with outdoor temperature during the warm season and study dwellings in higher socioeconomic status neighborhoods are significantly cooler. During the cool season, outdoor temperatures have little effect on indoor temperatures; however, indoor temperatures can range more than 10 °C between dwellings despite similar outdoor temperatures. Apartment buildings tend to be significantly warmer than houses and dwellings on higher floors are also significantly warmer than dwellings on lower floors. Outdoor specific humidity is positively associated with indoor specific and relative humidity, but there is no consistent relationship between outdoor and indoor relative humidity. Conclusions In New York City, the relationship between indoor and outdoor temperature and humidity conditions vary significantly between dwellings. These results can be used to inform studies of health outcomes for which temperature or humidity is an established factor affecting human health and highlights the need for more research on the determinants of indoor climate. PMID:24077420
Duff, Putu; Shoveller, Jean; Dobrer, Sabina; Ogilvie, Gina; Montaner, Julio; Chettiar, Jill; Shannon, Kate
2015-01-01
Background This study aims to: report on a newly developed ‘Safer Indoor Work Environmental Scale’ that characterizes the social, policy and physical features of indoor venues and social cohesion; and using this scale, longitudinally evaluate the association between these features on sex workers’ (SWs’) condom use for pregnancy prevention. Methods Drawing on a prospective open cohort of female SWs working in indoor venues, a newly-developed ‘Safer Indoor Work Environment Scale’ was used to build six multivariable models with generalized estimating equations (GEE), to determine the independent effects of social, policy and venue-based features and social cohesion on condom use. Results Of 588 indoor SWs, 63.6% used condoms for pregnancy prevention in the last month. In multivariable GEE analysis, the following venue-based features were significantly correlated with barrier contraceptive use for pregnancy prevention: managerial practices and venue safety policies (Adjusted Odds Ratio (AOR)=1.09; 95% Confidence Interval (95%CI) 1.01–1.17) access to sexual and reproductive health services/supplies (AOR=1.10; 95%CI 1.00–1.20) access to drug harm reduction (AOR=1.13; 95%CI 1.01–1.28), and social cohesion among workers (AOR=1.05; 95%CI 1.03–1.07). Access to security features was marginally associated with condom use (AOR=1.13; 95%CI 0.99–1.29). Conclusion The findings of the current study highlight how work environment and social cohesion among SWs are related to improved condom use. Given global calls for the decriminalization of sex work, and potential legislative reforms in Canada, this study points to the critical need for new institutional arrangements (e.g., legal and regulatory frameworks; labour standards) to support safer sex workplaces. PMID:25678713
Duff, Putu; Shoveller, Jean; Dobrer, Sabina; Ogilvie, Gina; Montaner, Julio; Chettiar, Jill; Shannon, Kate
2015-07-01
This study aims to report on a newly developed Safer Indoor Work Environmental Scale that characterises the social, policy and physical features of indoor venues and social cohesion; and using this scale, longitudinally evaluate the association between these features on sex workers' (SWs') condom use for pregnancy prevention. Drawing on a prospective open cohort of female SWs working in indoor venues, a newly developed Safer Indoor Work Environment Scale was used to build six multivariable models with generalised estimating equations (GEE), to determine the independent effects of social, policy and physical venue-based features and social cohesion on condom use. Of 588 indoor SWs, 63.6% used condoms for pregnancy prevention in the last month. In multivariable GEE analysis, the following venue-based features were significantly correlated with barrier contraceptive use for pregnancy prevention: managerial practices and venue safety policies (adjusted OR (AOR)=1.09; 95% CI 1.01 to 1.17), access to sexual and reproductive health services/supplies (AOR=1.10; 95% CI 1.00 to 1.20), access to drug harm reduction (AOR=1.13; 95% CI 1.01 to 1.28) and social cohesion among workers (AOR=1.05; 95% CI 1.03 to 1.07). Access to security features was marginally associated with condom use (AOR=1.13; 95% CI 0.99 to 1.29). The findings of the current study highlight how work environment and social cohesion among SWs are related to improved condom use. Given global calls for the decriminalisation of sex work, and potential legislative reforms in Canada, this study points to the critical need for new institutional arrangements (eg, legal and regulatory frameworks; labour standards) to support safer sex workplaces. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.