Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belzer, D. B.; Hadley, S. W.; Chin, S-M.
2008-10-01
The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called formore » the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings compared to the northern regions, a result possibly due to a small, offsetting increase in household air conditioning usage. (4) Changes in national traffic volume and motor gasoline consumption for passenger vehicles in 2007 were determined to be statistically insignificant and therefore, could not be attributed to Extended Daylight Saving Time.« less
NASA Astrophysics Data System (ADS)
Murray, Patrick L.
Government programs designed to decrease resource consumption, improve productivity and capitalize on extended daylight hours in the summer have been developed and implemented throughout the world for nearly three hundred years. In 2005, The United States government adopted an extended daylight savings program that increases the number of weeks where the country observes Daylight Saving Time (DST) from 31 to 35 weeks. The program took effect in March 2007. Arguments in support of DST programs highlight the portion of electricity consumption attributed to residential lighting in the evening hours. Adjusting clocks forward by one hour in summer months is believed to reduce electricity consumption due to lighting and therefore significantly reduce residential energy consumption during the period of DST. This paper evaluates the efficacy of the changes to DST resulting from the Energy Policy Act of 2005. The study focuses on changes to household electricity consumption during the extended four weeks of DST. Arizona, one of two states that continue to opt out of DST serves as the study's control for a comparison with neighboring states, Colorado, Nebraska, Nevada, New Mexico, Oklahoma, Texas and Utah. Results from the regression analysis of a Difference in Difference model indicate that contrary to evaluations by Congress and the Department of Energy, the four week period of Extended Daylight Saving Time does not produce a significant decrease in per capita electricity consumption in Southwestern states.
Hester, Nathan; Li, Ke; Schramski, John R; Crittenden, John
2012-04-30
Globally, residential energy consumption continues to rise due to a variety of trends such as increasing access to modern appliances, overall population growth, and the overall increase of electricity distribution. Currently, residential energy consumption accounts for approximately one-fifth of total U.S. energy consumption. This research analyzes the effectiveness of a range of energy-saving measures for residential houses in semi-arid climates. These energy-saving measures include: structural insulated panels (SIP) for exterior wall construction, daylight control, increased window area, efficient window glass suitable for the local weather, and several combinations of these. Our model determined that energy consumption is reduced by up to 6.1% when multiple energy savings technologies are combined. In addition, pre-construction technologies (structural insulated panels (SIPs), daylight control, and increased window area) provide roughly 4 times the energy savings when compared to post-construction technologies (window blinds and efficient window glass). The model also illuminated the importance variations in local climate and building configuration; highlighting the site-specific nature of this type of energy consumption quantification for policy and building code considerations. Published by Elsevier Ltd.
DOT National Transportation Integrated Search
1975-06-01
The analyses of the effects of Year-Round Daylight Saving Time were not conslusive because they could not be reliablyseparated from other changes occuring simultaneously including fuel availability constraints, speed limit reductions, Sunday gasoline...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
17 CFR 232.13 - Date of filing; adjustment of filing date.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed filed on.... Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in effect, shall be deemed... Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4...
Project Lateday : The Level of Accidents Under the Effect of Daylight Saving All Year
DOT National Transportation Integrated Search
1975-10-01
Year-round daylight saving time (YRDST) has recently been observed in the United States. The observance of double daylight saving time (DDST) is under some consideration. One of the principal expected effects of the adoption of these time systems is ...
Effects of daylight savings time changes on stock market volatility.
Berument, M Hakan; Dogan, Nukhet; Onar, Bahar
2010-04-01
The presence of daylight savings time effects on stock returns and on stock volatility was investigated using an EGARCH specification to model the conditional variance. The evidence gathered from the major United States stock markets for the period between 1967 and 2007 did not support the existence of the daylight savings time effect on stock returns or on volatility. Returns on the first business day following daylight savings time changes were not lower nor was the volatility higher, as would be expected if there were an effect.
Hicks, G J; Davis, J W; Hicks, R A
1998-06-01
On the hypothesis that sleepiness and alcohol interact to increase the risk of alcohol-related traffic fatalities, the percentages of alcohol-related fatal traffic crashes were assessed for the entire state of New Mexico for the years 1989-1992, for each of the seven days that preceded the changes to and from Daylight Savings Time and for each of the 14 days which followed the changes to and from Daylight Savings Time. Consistent with our hypothesis the percentage of alcohol-related fatal crashes increased significantly during the first seven days after these changes in Daylight Savings Time.
Daylight saving time transitions and hospital treatments due to accidents or manic episodes
Lahti, Tuuli A; Haukka, Jari; Lönnqvist, Jouko; Partonen, Timo
2008-01-01
Background Daylight saving time affects millions of people annually but its impacts are still widely unknown. Sleep deprivation and the change of circadian rhythm can trigger mental illness and cause higher accident rates. Transitions into and out of daylight saving time changes the circadian rhythm and may cause sleep deprivation. Thus it seems plausible that the prevalence of accidents and/or manic episodes may be higher after transition into and out of daylight saving time. The aim of this study was to explore the effects of transitions into and out of daylight saving time on the incidence of accidents and manic episodes in the Finnish population during the years of 1987 to 2003. Methods The nationwide data were derived from the Finnish Hospital Discharge Register. From the register we obtained the information about the hospital-treated accidents and manic episodes during two weeks before and two weeks after the transitions in 1987–2003. Results The results were negative, as the transitions into or out of daylight saving time had no significant effect on the incidence of accidents or manic episodes. Conclusion One-hour transitions do not increase the incidence of manic episodes or accidents which require hospital treatment. PMID:18302734
Daylight Saving Time Transitions and Road Traffic Accidents
Lahti, Tuuli; Nysten, Esa; Haukka, Jari; Sulander, Pekka; Partonen, Timo
2010-01-01
Circadian rhythm disruptions may have harmful impacts on health. Circadian rhythm disruptions caused by jet lag compromise the quality and amount of sleep and may lead to a variety of symptoms such as fatigue, headache, and loss of attention and alertness. Even a minor change in time schedule may cause considerable stress for the body. Transitions into and out of daylight saving time alter the social and environmental timing twice a year. According to earlier studies, this change in time-schedule leads to sleep disruption and fragmentation of the circadian rhythm. Since sleep deprivation decreases motivation, attention, and alertness, transitions into and out of daylight saving time may increase the amount of accidents during the following days after the transition. We studied the amount of road traffic accidents one week before and one week after transitions into and out of daylight saving time during years from 1981 to 2006. Our results demonstrated that transitions into and out of daylight saving time did not increase the number of traffic road accidents. PMID:20652036
17 CFR 240.0-2 - Business hours of the Commission.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Eastern Daylight Saving Time, whichever currently is in effect in Washington, DC, provided that hours for... 8 a.m. to 10 p.m., Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in... Saturdays, Sundays and federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight...
17 CFR 240.0-2 - Business hours of the Commission.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Eastern Daylight Saving Time, whichever currently is in effect in Washington, DC, provided that hours for... 8 a.m. to 10 p.m., Eastern Standard Time or Eastern Daylight Saving Time, whichever is currently in... Saturdays, Sundays and federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight...
47 CFR 73.99 - Presunrise service authorization (PSRA) and postsunset service authorization (PSSA).
Code of Federal Regulations, 2013 CFR
2013-10-01
... authorization. (c) Extended Daylight Saving Time Pre-Sunrise Authorizations: (1) Between the first Sunday in... presunrise operations during extended daylight saving time and shall issue conforming authorizations. These...
47 CFR 73.99 - Presunrise service authorization (PSRA) and postsunset service authorization (PSSA).
Code of Federal Regulations, 2011 CFR
2011-10-01
... authorization. (c) Extended Daylight Saving Time Pre-Sunrise Authorizations: (1) Between the first Sunday in... presunrise operations during extended daylight saving time and shall issue conforming authorizations. These...
A Study on the Optimal Duration of Daylight Saving Time (DST) in Korea
NASA Astrophysics Data System (ADS)
Mihn, Byeong-Hee; Ahn, Young Sook; Kim, Dong-Bin; Yang, Hong-Jin
2009-09-01
Daylight saving time aims at spending effective daylight in summer season. Korea had enforced daylight saving time twelve times from 1948 to 1988. Since 1988, it is not executed, but it is recently discussed the resumption of DST. In this paper, we investigate the trend of DST in other countries, review the history of DST in Korea, and suggest the optimal DST duration in terms of astronomical aspects (times of sunrise and sunset). We find that the starting day of DST in Korea is apt for the second Sunday in May or the second Sunday in April according to the time of sunrise or to the difference between Korean standard meridian and observer's, respectively. We also discuss time friction that might be caused by time difference between DST and Korea Standard Time (KST).
Daylighting as a design and energy strategy: Overview of opportunities and conflicts
NASA Astrophysics Data System (ADS)
Selkowitz, S.
1981-06-01
The potentials and problems associated with using daylight both to improve visual performance and interior aesthetics and to reduce electrical lighting energy consumption and peak electric loads are reviewed. Use of daylighting as a design strategy is not always synonymous with effective use of daylighting as an energy-saving strategy unless both approaches are jointly pursued by the design team. Criteria for visual performance, disability and discomfort glare, historical perspectives on daylight utilization, building form as a limit to daylight penetration, beam sunlighting strategies, luminous efficacy of daylight versus efficient electric light sources, comparative thermal impacts, peak load and load management potential, and nonenergy benefits are reviewed. Although the energy benefits of daylighting can be oversold, it is concluded that in most cases a solid understanding of the energy and design issues should produce energy efficiency and pleasing working environments.
Spectral Analysis of the Effects of Daylight Saving Time on Motor Vehicle Fatal Traffic Accidents
DOT National Transportation Integrated Search
1977-04-01
This report shows that Daylight Saving Time (DST) reduces the number of persons killed in motor vehicle fatal traffic accidents by about one percent. This estimate is based on a spectral (Fourier) analysis of these fatalities which utilizes a filteri...
Daylight Savings Time Transitions and the Incidence Rate of Unipolar Depressive Episodes.
Hansen, Bertel T; Sønderskov, Kim M; Hageman, Ida; Dinesen, Peter T; Østergaard, Søren D
2017-05-01
Daylight savings time transitions affect approximately 1.6 billion people worldwide. Prior studies have documented associations between daylight savings time transitions and adverse health outcomes, but it remains unknown whether they also cause an increase in the incidence rate of depressive episodes. This seems likely because daylight savings time transitions affect circadian rhythms, which are implicated in the etiology of depressive disorder. Therefore, we investigated the effects of daylight savings time transitions on the incidence rate of unipolar depressive episodes. Using time series intervention analysis of nationwide data from the Danish Psychiatric Central Research Register from 1995 to 2012, we compared the observed trend in the incidence rate of hospital contacts for unipolar depressive episodes after the transitions to and from summer time to the predicted trend in the incidence rate. The analyses were based on 185,419 hospital contacts for unipolar depression and showed that the transition from summer time to standard time were associated with an 11% increase (95% CI = 7%, 15%) in the incidence rate of unipolar depressive episodes that dissipated over approximately 10 weeks. The transition from standard time to summer time was not associated with a parallel change in the incidence rate of unipolar depressive episodes. This study shows that the transition from summer time to standard time was associated with an increase in the incidence rate of unipolar depressive episodes. Distress associated with the sudden advancement of sunset, marking the coming of a long period of short days, may explain this finding. See video abstract at, http://links.lww.com/EDE/B179.
Energy performance and savings potentials with skylights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1984-12-01
This study systematically explores the energy effects of skylight systems in a prototypical office building module and examines the savings from daylighting. For specific climates, roof/skylight characteristics are identified that minimize total energy or peak electrical demand. Simplified techniques for energy performance calculation are also presented based on a multiple regression analysis of our data base so that one may easily evaluate daylighting's effects on total and component energy loads and electrical peaks. This provides additional insights into the influence of skylight parameters on energy consumption and electrical peaks. We use the DOE-2.1B energy analysis program with newly incorporated daylightingmore » algorithms to determine hourly, monthly, and annual impacts of daylighting strategies on electrical lighting consumption, cooling, heating, fan power, peak electrical demands, and total energy use. A data base of more than 2000 parametric simulations for 14 US climates has been generated. Parameters varied include skylight-to-roof ratio, shading coefficient, visible transmittance, skylight well light loss, electric lighting power density, roof heat transfer coefficient, and electric lighting control type. 14 references, 13 figures, 4 tables.« less
ERIC Educational Resources Information Center
Raloff, Janet
1978-01-01
Presented are different research program developments aimed at reducing the consumption of electrical energy for artificial lights. Explains the idea of the dimmers, where the amount of incoming daylight regulates the current needed for the lamp. (GA)
Year-Round Daylight Saving Time Study : Volume 2. Supporting Studies
DOT National Transportation Integrated Search
1975-06-01
This volume contains detailed background material in support of findings of the Interim Report. It includes the findings of a survey of attifudes towards daylight saving conducted by the National Opinion Research Center; description of sunrise and su...
Rosenberg, Michael; Wood, Lisa
2010-02-01
To measure the impact of the introduction of daylight saving in Western Australia in December 2006 on when during the day adults engaged in physical activity. In early December 2006, 1,300 Western Australian adults were telephoned and asked about how the introduction of daylight saving would influence when during the day they typically engaged in physical activity. At the end of the daylight saving period in March 2007, 1,083 of the baseline cohort agreed to answer questions relating to how daylight saving had affected when during the day they were physically active. Almost half the cohort (45.5%) reported that daylight saving had affected when during the day they were physically active. During daylight saving fewer people exercised in the morning and more people exercised in the evening. When analysed at the individual level, 23% of the cohort ceased to exercise in the morning during daylight saving and 22% exercised in the evening only during daylight saving. In addition, to changes in when during the day people exercised, there was also an overall reduction in the average number of daily exercise sessions, with 8% not exercising at all during daylight saving. The results suggest that the introduction of daylight saving, a relatively modest compulsory change to increase daylight by one hour had an impact on patterns of when during the day people were physically active. The study results reinforce the value of focusing on policy as an effective means of supporting population behaviour change. © 2010 The Authors. Journal Compilation © 2010 Public Health Association of Australia.
Change in the Classroom Deportment of Children Following Change From Daylight Saving Time.
ERIC Educational Resources Information Center
Hicks, Robert A.; And Others
1980-01-01
The deportment of each student in a third-grade classroom was rated by the teacher before and after the fall change from daylight savings time, to see if this disruption in circadian rhythms alters behavior. The deportment of boys improved significantly while the deportment of girls was significantly disrupted. (Author/SJL)
A sensor-less LED dimming system based on daylight harvesting with BIPV systems.
Yoo, Seunghwan; Kim, Jonghun; Jang, Cheol-Yong; Jeong, Hakgeun
2014-01-13
Artificial lighting in office buildings typically requires 30% of the total energy consumption of the building, providing a substantial opportunity for energy savings. To reduce the energy consumed by indoor lighting, we propose a sensor-less light-emitting diode (LED) dimming system using daylight harvesting. In this study, we used light simulation software to quantify and visualize daylight, and analyzed the correlation between photovoltaic (PV) power generation and indoor illumination in an office with an integrated PV system. In addition, we calculated the distribution of daylight illumination into the office and dimming ratios for the individual control of LED lights. Also, we were able directly to use the electric power generated by PV system. As a result, power consumption for electric lighting was reduced by 40 - 70% depending on the season and the weather conditions. Thus, the dimming system proposed in this study can be used to control electric lighting to reduce energy use cost-effectively and simply.
The integration of daylighting with artificial lighting to enhance building energy performance
NASA Astrophysics Data System (ADS)
Al-Ashwal, Najib Taher; Hassan, Ahmad Sanusi
2017-10-01
In sustainable building designs, daylight is considered as an alternative source of light to artificial lighting. Daylight is an energy-free and efficient-cost lighting source. Natural light is the best source for light due to its good quality, which matches the visual response of the human eyes. Daylight positively affects people by providing a sense of liveliness and brightness in the living space. The positive impact of daylight on the building occupants' visual comfort, health and performance is well recognized. However, daylight is not widely utilized to supplement artificial lighting, because there is a lack of information and tools to evaluate daylighting and potentials for energy savings. The efficient utilization of natural lighting will not only affect the interior environment and the occupants' health and performance but also has a direct impact on the building energy performance. Therefore, this paper reviews and discusses the effects of daylighting on the building energy performance mainly in schools and office buildings. This includes lighting energy performance, total energy consumption, cooling load. The methods, which are used to estimate the possible reduction in total energy consumption, are also reviewed in this research paper. Previous studies revealed that a clear reduction can be obtained in the energy consumed by electric lighting, as well as in the total energy end-use when a suitable lighting control system is applied to utilize the available natural light.
Optimal integration of daylighting and electric lighting systems using non-imaging optics
NASA Astrophysics Data System (ADS)
Scartezzini, J.-L.; Linhart, F.; Kaegi-Kolisnychenko, E.
2007-09-01
Electric lighting is responsible for a significant fraction of electricity consumption within non-residential buildings. Making daylight more available in office and commercial buildings can lead as a consequence to important electricity savings, as well as to the improvement of occupants' visual performance and wellbeing. Over the last decades, daylighting technologies have been developed for that purpose, some of them having proven to be highly efficient such as anidolic daylighting systems. Based on non-imaging optics these optical devices were designed to achieve an efficient collection and redistribution of daylight within deep office rooms. However in order to benefit from the substantial daylight provision obtained through these systems and convert it into effective electricity savings, novel electric lighting strategies are required. An optimal integration of high efficacy light sources and efficient luminaries based on non-imaging optics with anidolic daylighting systems can lead to such novel strategies. Starting from the experience gained through the development of an Anidolic Integrated Ceiling (AIC), this paper presents an optimal integrated daylighting and electric lighting system. Computer simulations based on ray-tracing techniques were used to achieve the integration of 36W fluorescent tubes and non-imaging reflectors with an advanced daylighting system. Lighting power densities lower than 4 W/m2 can be achieved in this way within the corresponding office room. On-site monitoring of an integrated daylighting and electric lighting system carried out on a solar experimental building confirmed the energy and visual performance of such a system: it showed that low lighting power densities can be achieved by combining an anidolic daylighting system with very efficient electric light sources and luminaries.
Luminescent Solar Concentrator Daylighting
NASA Astrophysics Data System (ADS)
Bornstein, Jonathan G.
1984-11-01
Various systems that offer potential solutions to the problem of interior daylighting have been discussed in the literature. Virtually all of these systems rely on some method of tracking the sun along its azimuth and elevation, i.e., direct imaging of the solar disk. A simpler approach, however, involves a nontracking nonimaging device that effectively eliminates moving parts and accepts both the diffuse and direct components of solar radiation. Such an approach is based on a system that combines in a common luminaire the light emitted by luminescent solar concentrators (LSC), of the three primary colors, with a highly efficient artificial point source (HID metal halide) that automatically compensates for fluctuations in the LSC array via a daylight sensor and dimming ballast. A preliminary analysis suggests that this system could supply 90% of the lighting requirement, over the course of an 8 hour day, strictly from the daylight component under typical insolation con-ditions in the Southwest United States. In office buildings alone, the total aggregate energy savings may approach a half a quad annually. This indicates a very good potential for the realization of substantial savings in building electric energy consumption.
Teaching Science: Beats the Daylight Out of Me.
ERIC Educational Resources Information Center
Leyden, Michael B.
1995-01-01
Presents activities for observing, measuring, collecting, and graphing data about times of sunrise and sunset to teach an understanding about arrival of Daylight Savings Time in April. Also discusses seasonal affective disorder (SAD). (TM)
2009-03-26
annually ( McHugh , et al., 1998). USAF has used daylighting as an energy savings strategy in earlier studies (Holtz, 1990); and is pursuing it to meet...using renewable energy to generate electricity ( McHugh , et al., 1998). For example, traditional utility systems that are straining to meet peak...1998) found that lighting accounts for 40-50% of commercial energy consumption and McHugh , Burns, and Hittle (1998) stated that electric lighting and
The shift to and from daylight savings time and motor vehicle crashes.
Lambe, M; Cummings, P
2000-07-01
The objective of the study was to examine whether the shifts to and from daylight savings time in Sweden have short-term effects on the incidence of traffic crashes. A database maintained by the Swedish National Road Administration was used to examine crashes from 1984 through 1995, that occurred on state roads the Monday preceding, the Monday immediately after (index Monday), and the Monday 1 week after the change to daylight savings time in the spring and for the corresponding three Mondays in the autumn. The Mondays 1 week before and after the time changes were taken as representing the expected incidence of crashes. Crash incidence was calculated per 1000 person-years using population estimates for each year of the study. The association between 1 h of possible sleep loss and crash incidence was estimated by the incidence rate ratio from negative binomial regression. The incidence rate ratio was 1.04 (95% CI, 0.92-1.16) for a Monday on which drivers were expected to have had 1 h less sleep, compared with other Mondays. In the spring, the incidence rate ratio for crashes was 1.11 (95% CI, 0.93-1.31) for Mondays after the time change compared to other spring Mondays. The corresponding rate ratio for the fall was 0.98 (95% CI, 0.84-1.15) It was concluded that the shift to and from daylight savings time did not have measurable important immediate effects on crash incidence in Sweden.
ADASY (Active Daylighting System)
NASA Astrophysics Data System (ADS)
Vázquez-Moliní, Daniel; González-Montes, Mario; Fernández-Balbuena, Antonio Á.; Bernabéu, Eusebio; García-Botella, Ángel; García-Rodríguez, Lucas; Pohl, Wilfried
2009-08-01
The main objective of ADASY (Active Daylighting System) work is to design a façade static daylighting system oriented to office applications, mainly. The goal of the project is to save energy by guiding daylight into a building for lighting purpose. With this approach we can reduce the electrical load for artificial lighting, completing it with sustainable energy. The collector of the system is integrated on a vertical façade and its distribution guide is always horizontal inside of the false ceiling. ADASY is designed with a specific patent pending caption system, a modular light-guide and light extractor luminaire system. Special care has been put on the final cost of the system and its building integration purpose. The current ADASY configuration is able to illuminate 40 m2 area with a 300lx-400lx level in the mid time work hours; furthermore it has a good enough spatial uniformity distribution and a controlled glare. The data presented in this study are the result of simulation models and have been confirmed by a physical scaled prototype. ADASY's main advantages over regular illumination systems are: -Low maintenance; it has not mobile pieces and therefore it lasts for a long time and require little attention once installed. - No energy consumption; solar light continue working even if there has been a power outage. - High quality of light: the colour rendering of light is very high - Psychological benefits: People working with daylight get less stress and more comfort, increasing productivity. - Health benefits
Circadian occurrence of variceal bleeding in patients with liver cirrhosis.
Siringo, S; Bolondi, L; Sofia, S; Hermida, R C; Gramantieri, L; Gaiani, S; Piscaglia, F; Carbone, C; Misitano, B; Corinaldesi, R
1996-12-01
Several clinical events have a rhythmicity over the 24 h period. We assessed the presence of periodic rhythm in the occurrence of haematemesis in patients with liver cirrhosis under different daylight regimens, namely during standard time and during daylight savings. Over a 48 month period there were 212 consecutive admissions of 118 cirrhotics with variceal bleeding. Complete data were available for 181 episodes of bleeding: 121 (66.9%) started with haematemesis and 60 (33.1%) started with melaena. One hundred and two (56%) episodes occurred during daylight savings and 79 (44%) occurred during standard time. The cosinor test showed a 24 h biphasic peak for the occurrence of haematemesis (09.45 and 21.45 h). Moreover, a biphasic diurnal asymmetric frequency was also found by multiple component rhythmometry. The time peaks of onset of variceal haemorrhage did not change significantly during standard time and daylight savings. Patients with more than one haematemesis episode significantly bled over the same time interval. The present study confirms that over the 24 h period variceal bleeding in cirrhotic patients occurs with a predictable rhythmicity that does not seem to be under the control of the light-dark cycle. The finding of a chronorisk for variceal haemorrhage addresses specific questions for pathophysiological studies as well as for new treatment strategies.
NASA Astrophysics Data System (ADS)
Granderson, Jessica Ann
2007-12-01
The need for sustainable, efficient energy systems is the motivation that drove this research, which targeted the design of an intelligent commercial lighting system. Lighting in commercial buildings consumes approximately 13% of all the electricity generated in the US. Advanced lighting controls1 intended for use in commercial office spaces have proven to save up to 45% in electricity consumption. However, they currently comprise only a fraction of the market share, resulting in a missed opportunity to conserve energy. The research goals driving this dissertation relate directly to barriers hindering widespread adoption---increase user satisfaction, and provide increased energy savings through more sophisticated control. To satisfy these goals an influence diagram was developed to perform daylighting actuation. This algorithm was designed to balance the potentially conflicting lighting preferences of building occupants, with the efficiency desires of building facilities management. A supervisory control policy was designed to implement load shedding under a demand response tariff. Such tariffs offer incentives for customers to reduce their consumption during periods of peak demand, trough price reductions. In developing the value function occupant user testing was conducted to determine that computer and paper tasks require different illuminance levels, and that user preferences are sufficiently consistent to attain statistical significance. Approximately ten facilities managers were also interviewed and surveyed to isolate their lighting preferences with respect to measures of lighting quality and energy savings. Results from both simulation and physical implementation and user testing indicate that the intelligent controller can increase occupant satisfaction, efficiency, cost savings, and management satisfaction, with respect to existing commercial daylighting systems. Several important contributions were realized by satisfying the research goals. A general model of a daylighted environment was designed, and a practical means of user preference identification was defined. Further, a set of general procedures were identified for the design of human-centered sensor-based decision-analytic systems, and for the identification of the allowable uncertainty in nodes of interest. To confirm generality, a vehicle health monitoring problem was defined and solved using these two procedures. 1'Daylighting' systems use sensors to determine room occupancy and available sunlight, and automatically dim the lights in response.
A computer program for analyzing the energy consumption of automatically controlled lighting systems
NASA Astrophysics Data System (ADS)
1982-01-01
A computer code to predict the performance of controlled lighting systems with respect to their energy saving capabilities is presented. The computer program provides a mathematical model from which comparisons of control schemes can be made on an economic basis only. The program does not calculate daylighting, but uses daylighting values as input. The program can analyze any of three power input versus light output relationships, continuous dimming with a linear response, continuous dimming with a nonlinear response, or discrete stepped response. Any of these options can be used with or without daylighting, making six distinct modes of control system operation. These relationships are described in detail. The major components of the program are discussed and examples are included to explain how to run the program.
Ambient air conditions and variation in urban trail use.
Holmes, Ann M; Lindsey, Greg; Qiu, Chenchen
2009-11-01
This study examines the effect of air quality and administrative policies on use of urban trails in Indianapolis, IN. Attention is focused on two policy variables: (1) issuance of air pollution advisories and (2) the adoption of Daylight Savings Time. Results suggest that while trail use varies with air quality, current public advisories regarding air pollution may be of limited effectiveness in reducing trail users' exposures to hazardous pollutants. In contrast, the adoption of Daylight Savings Time was associated with a statistically significant increase in traffic levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thayer, B.M.
A daylight office building built for Lockheed Martin near San Francisco has saved half a million dollars on energy bills and several times more due to reduced absenteeism and improved employee productivity. The building design incorporates soft daylight throughout the interior of the building. This article discusses the following topics in relationship to the building design: design for the climate; deep daylighting; integrated electric lighting; mechanical system; energy performance; the productivity story.
Predicting energy savings attributed to daylighting
NASA Astrophysics Data System (ADS)
Robbins, C. L.
1982-08-01
A method is described for estimating a building's energy savings attributed to daylighting by predicting the percentage of the year that the electric lighting system is not in use. This depends on the particular control strategy chosen, a standard work year, and the amount of light (as a daylight factor) reaching on daylight and sunlight availability for selected cities in the United States.
Daylight saving time can decrease the frequency of wildlife–vehicle collisions
Ellis, William A.; FitzGibbon, Sean I.; Barth, Benjamin J.; Niehaus, Amanda C.; David, Gwendolyn K.; Taylor, Brendan D.; Matsushige, Helena; Melzer, Alistair; Bercovitch, Fred B.; Carrick, Frank; Jones, Darryl N.; Dexter, Cathryn; Gillett, Amber; Predavec, Martin; Lunney, Dan
2016-01-01
Daylight saving time (DST) could reduce collisions with wildlife by changing the timing of commuter traffic relative to the behaviour of nocturnal animals. To test this idea, we tracked wild koalas (Phascolarctos cinereus) in southeast Queensland, where koalas have declined by 80% in the last 20 years, and compared their movements with traffic patterns along roads where they are often killed. Using a simple model, we found that DST could decrease collisions with koalas by 8% on weekdays and 11% at weekends, simply by shifting the timing of traffic relative to darkness. Wildlife conservation and road safety should become part of the debate on DST. PMID:27881767
Does Daylight Savings Time encourage physical activity?
Zick, Cathleen D
2014-07-01
Extending Daylight Savings Time (DST) has been identified as a policy intervention that may encourage physical activity. However, there has been little research on the question of if DST encourages adults to be more physically active. Data from residents of Arizona, Colorado, New Mexico, and Utah ages 18-64 who participated in the 2003-2009 American Time Use Survey are used to assess whether DST is associated with increased time spent in moderate-to-vigorous physical activity (MVPA). The analysis capitalizes on the natural experiment created because Arizona does not observe DST. Both bivariate and multivariate analyses indicate that shifting 1 hour of daylight from morning to evening does not impact MVPA of Americans living in the southwest. While DST may affect the choices people make about the timing and location of their sports/recreational activities, the potential for DST to serve as a broad-based intervention that encourages greater sports/recreation participation is not supported by this analysis. Whether this null effect would persist in other climate situations is an open question.
Daylight saving time can decrease the frequency of wildlife-vehicle collisions.
Ellis, William A; FitzGibbon, Sean I; Barth, Benjamin J; Niehaus, Amanda C; David, Gwendolyn K; Taylor, Brendan D; Matsushige, Helena; Melzer, Alistair; Bercovitch, Fred B; Carrick, Frank; Jones, Darryl N; Dexter, Cathryn; Gillett, Amber; Predavec, Martin; Lunney, Dan; Wilson, Robbie S
2016-11-01
Daylight saving time (DST) could reduce collisions with wildlife by changing the timing of commuter traffic relative to the behaviour of nocturnal animals. To test this idea, we tracked wild koalas (Phascolarctos cinereus) in southeast Queensland, where koalas have declined by 80% in the last 20 years, and compared their movements with traffic patterns along roads where they are often killed. Using a simple model, we found that DST could decrease collisions with koalas by 8% on weekdays and 11% at weekends, simply by shifting the timing of traffic relative to darkness. Wildlife conservation and road safety should become part of the debate on DST. © 2016 The Author(s).
Predicting energy savings attributed to daylighting
NASA Astrophysics Data System (ADS)
Robbins, C. L.
1983-11-01
A method for estimating a building's energy savings attributable to daylighting by predicting the percentage of the year that the electric lighting system is not in use is described. This method depends upon the particular control stragegy chosen, a standard work year, and the amount of light (as a daylight factor, DF) reaching any given station in the building.
NASA Astrophysics Data System (ADS)
Cárdenas, J.; Osma, G.; Caicedo, C.; Torres, A.; Sánchez, S.; Ordóñez, G.
2016-07-01
This research shows the energy analysis of the Electrical Engineering Building, located on campus of the Industrial University of Santander in Bucaramanga - Colombia. This building is a green pilot for analysing energy saving strategies such as solar pipes, green roof, daylighting, and automation, among others. Energy analysis was performed by means of DesignBuilder software from virtual model of the building. Several variables were analysed such as air temperature, relative humidity, air velocity, daylighting, and energy consumption. According to two criteria, thermal load and energy consumption, critical areas were defined. The calibration and validation process of the virtual model was done obtaining error below 5% in comparison with measured values. The simulations show that the average indoor temperature in the critical areas of the building was 27°C, whilst relative humidity reached values near to 70% per year. The most critical discomfort conditions were found in the area of the greatest concentration of people, which has an average annual temperature of 30°C. Solar pipes can increase 33% daylight levels into the areas located on the upper floors of the building. In the case of the green roofs, the simulated results show that these reduces of nearly 31% of the internal heat gains through the roof, as well as a decrease in energy consumption related to air conditioning of 5% for some areas on the fourth and fifth floor. The estimated energy consumption of the building was 69 283 kWh per year.
Testing simulation and structural models with applications to energy demand
NASA Astrophysics Data System (ADS)
Wolff, Hendrik
2007-12-01
This dissertation deals with energy demand and consists of two parts. Part one proposes a unified econometric framework for modeling energy demand and examples illustrate the benefits of the technique by estimating the elasticity of substitution between energy and capital. Part two assesses the energy conservation policy of Daylight Saving Time and empirically tests the performance of electricity simulation. In particular, the chapter "Imposing Monotonicity and Curvature on Flexible Functional Forms" proposes an estimator for inference using structural models derived from economic theory. This is motivated by the fact that in many areas of economic analysis theory restricts the shape as well as other characteristics of functions used to represent economic constructs. Specific contributions are (a) to increase the computational speed and tractability of imposing regularity conditions, (b) to provide regularity preserving point estimates, (c) to avoid biases existent in previous applications, and (d) to illustrate the benefits of our approach via numerical simulation results. The chapter "Can We Close the Gap between the Empirical Model and Economic Theory" discusses the more fundamental question of whether the imposition of a particular theory to a dataset is justified. I propose a hypothesis test to examine whether the estimated empirical model is consistent with the assumed economic theory. Although the proposed methodology could be applied to a wide set of economic models, this is particularly relevant for estimating policy parameters that affect energy markets. This is demonstrated by estimating the Slutsky matrix and the elasticity of substitution between energy and capital, which are crucial parameters used in computable general equilibrium models analyzing energy demand and the impacts of environmental regulations. Using the Berndt and Wood dataset, I find that capital and energy are complements and that the data are significantly consistent with duality theory. Both results would not necessarily be achieved using standard econometric methods. The final chapter "Daylight Time and Energy" uses a quasi-experiment to evaluate a popular energy conservation policy: we challenge the conventional wisdom that extending Daylight Saving Time (DST) reduces energy demand. Using detailed panel data on half-hourly electricity consumption, prices, and weather conditions from four Australian states we employ a novel 'triple-difference' technique to test the electricity-saving hypothesis. We show that the extension failed to reduce electricity demand and instead increased electricity prices. We also apply the most sophisticated electricity simulation model available in the literature to the Australian data. We find that prior simulation models significantly overstate electricity savings. Our results suggest that extending DST will fail as an instrument to save energy resources.
Hybrid daylight/light-emitting diode illumination system for indoor lighting.
Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei
2014-03-20
A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.
LeRoy Doggett and Daylight Saving Time: A Reminiscence
NASA Astrophysics Data System (ADS)
Bartky, I. R.
1997-12-01
Daylight Saving Time (DST) has been a concern of Congress ever since its adoption in 1918. Yet, not until 1976 did Members of Congress have astronomical, geographic and demographic information in terms of the country's Standard Time zones. This information and various impact analyses were developed by the National Bureau of Standards (NBS) at the request of the House of Representatives, which was reviewing the effects of a two-year, DST experiment on the American public. The displays in the study gave legislators a way to consider alternate observance periods in a systematic manner. The leader of the DST study team will detail LeRoy Doggett's involvement during the hectic, three-month analysis period that culminated with NBS officials testifying before Congress.
76 FR 18467 - Pattern of Violations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... Eastern Daylight Savings Time on April 18, 2011. ADDRESSES: Submit comments by any of the following... proposed rule addressing Pattern of Violations (POV). This extension gives commenters additional time to...
Impact of daylight savings time on spontaneous pregnancy loss in in vitro fertilization patients.
Liu, Constance; Politch, Joseph A; Cullerton, Evan; Go, Kathryn; Pang, Samuel; Kuohung, Wendy
2017-01-01
Transition into daylight savings time (DST) has studied negative impacts on health, but little is known regarding impact on fertility. This retrospective cohort study evaluates DST impact on pregnancy and pregnancy loss rates in 1,654 autologous in vitro fertilization cycles (2009 to 2012). Study groups were identified based on the relationship of DST to embryo transfer. Pregnancy rates were similar in Spring and Fall (41.4%, 42.2%). Pregnancy loss rates were also comparable between Spring and Fall (15.5%, 17.1%), but rates of loss were significantly higher in Spring when DST occurred after embryo transfer (24.3%). Loss was marked in patients with a history of prior spontaneous pregnancy loss (60.5%).
Goodman, Anna; Page, Angie S; Cooper, Ashley R
2014-10-23
It has been proposed that introducing daylight saving measures could increase children's physical activity, but there exists little research on this issue. This study therefore examined associations between time of sunset and activity levels, including using the bi-annual 'changing of the clocks' as a natural experiment. 23,188 children aged 5-16 years from 15 studies in nine countries were brought together in the International Children's Accelerometry Database. 439 of these children were of particular interest for our analyses as they contributed data both immediately before and after the clocks changed. All children provided objectively-measured physical activity data from Actigraph accelerometers, and we used their average physical activity level (accelerometer counts per minute) as our primary outcome. Date of accelerometer data collection was matched to time of sunset, and to weather characteristics including daily precipitation, humidity, wind speed and temperature. Adjusting for child and weather covariates, we found that longer evening daylight was independently associated with a small increase in daily physical activity. Consistent with a causal interpretation, the magnitude of these associations was largest in the late afternoon and early evening and these associations were also evident when comparing the same child just before and just after the clocks changed. These associations were, however, only consistently observed in the five mainland European, four English and two Australian samples (adjusted, pooled effect sizes 0.03-0.07 standard deviations per hour of additional evening daylight). In some settings there was some evidence of larger associations between daylength and physical activity in boys. There was no evidence of interactions with weight status or maternal education, and inconsistent findings for interactions with age. In Europe and Australia, evening daylight seems to play a causal role in increasing children's activity in a relatively equitable manner. Although the average increase in activity is small in absolute terms, these increases apply across all children in a population. Moreover, these small effect sizes actually compare relatively favourably with the typical effect of intensive, individual-level interventions. We therefore conclude that, by shifting the physical activity mean of the entire population, the introduction of additional daylight saving measures could yield worthwhile public health benefits.
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
34 CFR 101.33 - Filing and service.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... to 5:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only on exhibits and transcripts of testimony need be filed. For...
17 CFR 171.3 - Business address; hours.
Code of Federal Regulations, 2014 CFR
2014-04-01
.... until 4:45 p.m., eastern standard time or eastern daylight savings time, whichever is currently in effect in Washington, DC. [55 FR 41068, Oct. 9, 1990, as amended at 60 FR 49336, Sept. 25, 1995] ...
Wagner, David T; Barnes, Christopher M; Lim, Vivien K G; Ferris, D Lance
2012-09-01
The Internet is a powerful tool that has changed the way people work. However, the ubiquity of the Internet has led to a new workplace threat to productivity-cyberloafing. Building on the ego depletion model of self-regulation, we examine how lost and low-quality sleep influence employee cyberloafing behaviors and how individual differences in conscientiousness moderate these effects. We also demonstrate that the shift to Daylight Saving Time (DST) results in a dramatic increase in cyberloafing behavior at the national level. We first tested the DST-cyberloafing relation through a national quasi-experiment, then directly tested the relation between sleep and cyberloafing in a closely controlled laboratory setting. We discuss the implications of our findings for theory, practice, and future research.
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2014 CFR
2014-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2012 CFR
2012-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2011 CFR
2011-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
21 CFR 1316.45 - Filings; address; hours.
Code of Federal Regulations, 2013 CFR
2013-04-01
... through Friday from 8:30 a.m. to 5 p.m. eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time, except on national legal holidays. Documents shall be dated...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
12 CFR 11.3 - Filing requirements and inspection of documents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... submitted by direct transmission on or before 10 p.m. Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect, shall be deemed filed on the same business day. (4) Mandatory compliance...
Options for reducing carbon dioxide emissions
NASA Astrophysics Data System (ADS)
Rosenfeld, Arthur H.; Price, Lynn
1992-03-01
Improvements in energy efficiency can significantly reduce the annual growth in greenhouse gas emissions. Such improvements occur when energy intensity is reduced; no reduction in energy services is required. Using the concept of ``cost of conserved energy'' to develop conservation supply curves similar to resource supply curves, researchers consistently find that electricity and natural gas savings of nearly 50% of current consumption are possible for U.S. buildings. Such reductions in energy consumption directly reduce emissions of greenhouse gases. To capture these savings, we must continue to develop energy-efficient technologies and strategies. This paper describes three recent energy-efficient technologies that benefitted from energy conservation research and development (R&D) funding: high-frequency ballasts, compact fluorescent lamps, and low-emissivity windows. Other advanced technologies and strategies of spectrally selective windows, superwindows, electrochromic windows, advanced insulation, low-flow showerheads, improved recessed lamp fixtures, whitening surfaces and planting urban trees, daylighting, and thermal energy storage are also discussed.
Aldasouqi, Saleh A; Reed, Amy J
2014-11-01
The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients' visits, and should remind their patients to always verify these settings. © 2014 Diabetes Technology Society.
Pitfalls of Insulin Pump Clocks
Reed, Amy J.
2014-01-01
The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
38 CFR 18b.22 - Filing and service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... excepted) from 8 a.m. to 4:30 p.m., eastern standard or daylight saving time, whichever is effective in the District of Columbia at the time. Originals only of exhibits and transcripts of testimony need be filed...
36 CFR 1150.23 - Filing and service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
17 CFR 230.459 - Calculation of effective date.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of 24 hours each from 5:30 p.m. eastern standard time or eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date of filing. [Reg. C, 12 FR 4075, June...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, T.
1997-12-31
As part of the ACT{sup 2} project, sponsored by a major northern California utility, two occupied single-story commercial buildings were equipped with similar yet different daylighting systems in an effort to reduce electric lighting loads and provide a better workspace. The daylighting system, at the newly constructed 15,000 sq.ft. California State Automobile Association (CSAA) office building in Antioch, California, incorporates skylights with louvers, perforated blinds on the windows, and dimming ballasts which control T8 fluorescent fixtures. At the 7,500 sq.ft. retrofitted Verifone office building in Auburn, California, the building required a different kind of skylight to provide daylighting. Die tomore » the 10 foot attic space on the single-story building, a tubular-type of skylight was installed. The tubular skylight incorporates a long cylinder with a reflective internal surface to direct available sunlight into the workspace through a white diffuser. In addition, T8 fluorescent fixtures were controlled by dimming ballasts and light level controls. Annual lighting energy consumption at the CSAA building was reduced by 32% with a favorable reaction from the occupants. While the occupant response to the lighting at Verifone was generally good, thee were some problems in calibrating the lighting controls, thereby reducing energy savings.« less
36 CFR § 1150.23 - Filing and service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (Federal legal holidays excepted) from 9 a.m. to 5:30 p.m. Standard or Daylight Savings Time, whichever is effective in the city where the office of the judge is located at the time. (c) Service. Service of one copy...
Daylighting Strategies Promote Healthy High Performance Buildings
ERIC Educational Resources Information Center
Gille, Steve
2010-01-01
There are many reasons to incorporate daylighting into the building or renovation of K-16 learning facilities. Benefits include increased productivity for students and staff, improved health, a better connection to the outdoors, energy savings and better quality of light. Add the role daylighting can play in LEED certification and it's clear that…
None
2018-02-14
Daylightingâthe use of windows or skylights for natural lighting and temperature regulationâis one building strategy that can save money for homeowners and businesses. Highly efficient, strategically placed windows maximize the use of natural daylight in a building, lowering the need for artificial lighting without causing heating or cooling problems.
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2012-10-01 2012-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2014-10-01 2014-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2013-10-01 2013-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
49 CFR 71.2 - Annual advancement of standard time.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., requires that the standard time of each State observing Daylight Saving Time shall be advanced 1 hour... 49 Transportation 1 2011-10-01 2011-10-01 false Annual advancement of standard time. 71.2 Section 71.2 Transportation Office of the Secretary of Transportation STANDARD TIME ZONE BOUNDARIES § 71.2...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2010 CFR
2010-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2014 CFR
2014-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2013 CFR
2013-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2011 CFR
2011-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
17 CFR 260.7a-4 - Calculation of time.
Code of Federal Regulations, 2012 CFR
2012-04-01
... eastern daylight-saving time, whichever is in effect at the principal office of the Commission on the date... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Calculation of time. 260.7a-4... time. Saturdays, Sundays and holidays shall be counted in computing the effective date of applications...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffmann, Sabine; Lee, Eleanor
Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems.more » While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption« less
75 FR 41239 - Sunshine Act; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-15
... LEGAL SERVICES CORPORATION Sunshine Act; Notice of Meeting TIME AND DATE: The Legal Services Corporation Board of Directors' Search Committee for LSC President (``Search Committee'' or ``Committee'') will meet on July 20, 2010. The meeting will begin at 4 p.m. (Central Daylight Savings Time) and...
Joining the Great Plains in Space, Place, and Time: Questioning a Time Zone Boundary
ERIC Educational Resources Information Center
Kuper, Rob
2011-01-01
Standard time zone boundaries are invisible in the landscape, yet they abruptly delineate a temporal difference of one hour between two large areas located relative to one another on Earth. In most cases, standard time zone boundaries follow political ones and define areas within which daylight saving time (DST)--the seasonal advancement of…
Adverse Effects of Daylight Saving Time on Adolescents' Sleep and Vigilance
Medina, Diana; Ebben, Matthew; Milrad, Sara; Atkinson, Brianna; Krieger, Ana C.
2015-01-01
Study Objectives: Daylight saving time (DST) has been established with the intent to reduce energy expenditure, however unintentional effects on sleep and vigilance have not been consistently measured. The objective of this study was to test the hypothesis that DST adversely affects high school students' sleep and vigilance on the school days following its implementation. Methods: A natural experiment design was used to assess baseline and post-DST differences in objective and subjective measures of sleep and vigilance by actigraphy, sleep diary, sleepiness scale, and psychomotor vigilance testing (PVT). Students were tested during school days immediately preceding and following DST. Results: A total of 40 high school students were enrolled in this study; 35 completed the protocol. Sleep duration declined by an average of 32 minutes on the weeknights post-DST, reflecting a cumulative sleep loss of 2 h 42 min as compared to the baseline week (p = 0.001). This finding was confirmed by sleep diary analyses, reflecting an average sleep loss of 27 min/night (p = 0.004) post-DST. Vigilance significantly deteriorated, with a decline in PVT performance post-DST, resulting in longer reaction times (p < 0.001) and increased lapses (p < 0.001). Increased daytime sleepiness was also demonstrated (p < 0.001). Conclusions: The early March DST onset adversely affected sleep and vigilance in high school students resulting in increased daytime sleepiness. Larger scale evaluations of sleep impairments related to DST are needed to further quantify this problem in the population. If confirmed, measures to attenuate sleep loss post-DST should be implemented. Citation: Medina D, Ebben M, Milrad S, Atkinson B, Krieger AC. Adverse effects of daylight saving time on adolescents' sleep and vigilance. J Clin Sleep Med 2015;11(8):879–884. PMID:25979095
75 FR 35801 - Meeting of the National Drinking Water Advisory Council-Notice of Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-23
... a.m. to noon, Eastern Daylight Savings Time. ADDRESSES: The meeting will be held at the Hotel... ensure adequate time for public involvement, individuals or organizations interested in presenting an... to give EPA as much time as possible to process your request. Dated: June 17, 2010. Cynthia C...
Code of Federal Regulations, 2013 CFR
2013-04-01
... means any hour between 8:15 a.m. and 4:45 p.m. Business day and business hour are Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect in Washington, DC, on all days... ENTITIES § 40.1 Definitions. As used in this part: (a) Business day means the intraday period of time...
Code of Federal Regulations, 2012 CFR
2012-04-01
... means any hour between 8:15 a.m. and 4:45 p.m. Business day and business hour are Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect in Washington, DC, on all days... ENTITIES § 40.1 Definitions. As used in this part: (a) Business day means the intraday period of time...
Code of Federal Regulations, 2014 CFR
2014-04-01
... means any hour between 8:15 a.m. and 4:45 p.m. Business day and business hour are Eastern Standard Time or Eastern Daylight Savings Time, whichever is currently in effect in Washington, DC, on all days... ENTITIES § 40.1 Definitions. As used in this part: (a) Business day means the intraday period of time...
Reduction of lighting energy consumption in office buildings through improved daylight design
NASA Astrophysics Data System (ADS)
Papadouri, Maria Violeta Prado
This study aims to investigate the lighting energy consumption in office buildings and the options for its reduction. One way to reduce lighting energy consumption is by improving the daylight design. A better use of daylight in buildings might be an outcome from the effort made in different directions. Like the improvement of a building's fabric and layout, the materials, even the furniture in a space influences the daylight quality considerably. Also very important role in lighting energy consumption has the development of more efficient lighting technology like the electric lighting control systems, such as photo sensors and occupancy sensors. Both systems are responsible so that the electric light is not used without reason. As the focusing area of this study, is to find ways to improve the daylight use in buildings, a consequent question is which are the methods provided in order to achieve this The accuracy of the methodology used is also an important issue in order to achieve reliable results. The methodology applied in this study includes the analysis of a case study by taking field measurements and computer simulations. The first stage included gathering information about the lighting design of the building and monitoring the light levels, both from natural and from the electric lighting. The second stage involved testing with computer simulations, different parameters that were expected to improve the daylight exploitation of the specific area. The results of the field measurements showed that the main problems of the space were the low natural light levels and the poor daylight distribution. The annual electric lighting energy consumption, as it was calculated with the use of computer simulations, represented the annual energy consumption of a typical air-conditioned prestige office building (energy consumption guide 19, for energy use in offices, 2000). After several computer simulations, the results showed that initial design parameters of the building can affect the lighting energy consumption of the space significantly. On the other hand, relatively small changes, like changing the reflectance of the surfaces and the lighting control systems can make even more difference to the light quality of the space and the reduction of lighting energy consumption.
Code of Federal Regulations, 2013 CFR
2013-07-01
... are between 8:45 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate during...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Code of Federal Regulations, 2014 CFR
2014-07-01
... are between 8:45 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate during...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Designed To Maximize Learning and Minimize Costs.
ERIC Educational Resources Information Center
Dolan, Thomas G.
2002-01-01
Describes how the Durant Road Middle School in Raleigh, North Carolina sets a new standard in environmental school design. "Daylighting," bringing daylight into the building for psychological, health, and energy-saving benefits, plays a central role in the design. (EV)
Advanced Lighting Controls for Reducing Energy Use and Cost in DoD Installations
2013-03-01
of advanced lighting control strategies including occupancy sensing, light tuning, daylight harvesting and proper lighting design is an effective way...details of this project and the results obtained. 15. SUBJECT TERMS Integrated lighting controls, occupancy sensing, daylight harvesting , personalized...provide energy savings through occupancy sensing, dimming and daylight harvesting . II. Dynalite is a distributed control-based, wired networked building
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-27
... Eastern Daylight Saving Time on June 20, 2011. ADDRESSES: Comments must be identified with ``RIN 1219-AB64... commenters additional time to review and comment on the proposed rule. DATES: The comment period for the... providing additional time for interested parties to submit comments. MSHA is extending the comment period...
Sleep Time: Media Hype vs. Diary Data
ERIC Educational Resources Information Center
Michelson, William
2011-01-01
Sleep duration has figured into claims of two trends promoted recently as dysfunctional in the mass media. One is the observation that the population at large is sleeping less than before. The second is that the annual change from Standard Time to Daylight Savings (or summer) Time causes adverse effects, largely through the loss of an hour's…
Code of Federal Regulations, 2010 CFR
2010-07-01
... business hours are between 8:15 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Code of Federal Regulations, 2011 CFR
2011-07-01
... business hours are between 8:15 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
Code of Federal Regulations, 2012 CFR
2012-07-01
... business hours are between 8:15 a.m. and 4:45 p.m., eastern standard or daylight saving time as appropriate...; computation of time; representation of parties. 966.6 Section 966.6 Postal Service UNITED STATES POSTAL... time; representation of parties. (a) Filing. All documents required under this part must be filed by...
NASA Astrophysics Data System (ADS)
Zastrow, Armin; Wittwer, Volker
1986-09-01
The interest in efficient daylighting systems has grown recently, due to their potential for saving a considerable amount of electrical energy used for lighting purposes. In this paper we discuss the properties of daylighting systems based on either fluorescent planar concentrators and transparent light guiding plates or light pipes coated with highly reflective silver coated plastic films. Finally we give first results from a demonstration project, daylighting systems in the students' living quarters in Stuttgart-Hohenheim, which is supported by the Commission of the European Communities.
The impact of translucent fabric shades and control strategies on energy savings and visual quality
NASA Astrophysics Data System (ADS)
Wankanapon, Pimonmart
Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2013 CFR
2013-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2014 CFR
2014-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 232.12 - Business hours of the Commission.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., is open each day, except Saturdays, Sundays, and federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... the filing of documents pursuant to the Acts or the rules and regulations thereunder are as set forth...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2012 CFR
2012-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 230.110 - Business hours of the Commission.
Code of Federal Regulations, 2011 CFR
2011-04-01
... open each day, except Saturdays, Sundays, and Federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... Commission each day, except Saturdays, Sundays and federal holidays, from 5:30 p.m. to 10 p.m., Eastern...
17 CFR 232.12 - Business hours of the Commission.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., is open each day, except Saturdays, Sundays, and federal holidays, from 9 a.m. to 5:30 p.m., Eastern... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time... the filing of documents pursuant to the Acts or the rules and regulations thereunder are as set forth...
77 FR 22666 - Payment System Risk Policy; Daylight Overdraft Posting Rules
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-17
... of separately-sorted savings bonds and to eliminate a reference to the contractual clearing balance... clearing balance program are effective July 12, 2012. FOR FURTHER INFORMATION CONTACT: Susan V. Foley... account balances according to a set of ``posting rules'' that determine the intraday timing of debits and...
NASA Astrophysics Data System (ADS)
Zastrow, Armin; Wittwer, Volker
1987-02-01
Efficient daylighting systems have recently attracted increasing interest due to their potential for saving a condiderable amount of electrical energy used for lighting purposes. In this paper we discuss the properties of daylighting systems based on either fluorescent planar concentrators (FPC's) and transparent light guiding plates or light pipes coated with a highly reflective silver coated plastic film (3M Silverlux film). First results on daylighting systems in the students' living quarters in Stuttgart-Hohenheim will be presented. This is a demonstration project which is supported by the Commission of the European Communities.
Effects of skylight parameters on daylighting energy savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1985-05-01
Skylight parameters that affect lighting, cooling, heating, fan, and total energy use in office buildings are examined using the state-of-the-art building energy analysis computer code, DOE-2.1B. The lighting effects of skylight spatial distribution, skylight area, skylight visible transmission, well factor, illumination setpoint, interior partitions, ceiling height, and glazing characteristics are discussed. This study serves as the foundation for the creation of a DOE-2.1B data base and design tools for estimating daylighting energy savings from skylights. 13 refs., 9 figs., 1 tab.
Efficiency in energy production and consumption
NASA Astrophysics Data System (ADS)
Kellogg, Ryan Mayer
This dissertation deals with economic efficiency in the energy industry and consists of three parts. The first examines how joint experience between pairs of firms working together in oil and gas drilling improves productivity. Part two asks whether oil producers time their drilling optimally by taking real options effects into consideration. Finally, I investigate the efficiency with which energy is consumed, asking whether extending Daylight Saving Time (DST) reduces electricity use. The chapter "Learning by Drilling: Inter-Firm Learning and Relationship Persistence in the Texas Oilpatch" examines how oil production companies and the drilling rigs they hire improve drilling productivity by learning through joint experience. I find that the joint productivity of a lead firm and its drilling contractor is enhanced significantly as they accumulate experience working together. Moreover, this result is robust to other relationship specificities and standard firm-specific learning-by-doing effects. The second chapter, "Drill Now or Drill Later: The Effect of Expected Volatility on Investment," investigates the extent to which firms' drilling behavior accords with a key prescription of real options theory: irreversible investments such as drilling should be deferred when the expected volatility of the investments' payoffs increases. I combine detailed data on oil drilling with expectations of future oil price volatility that I derive from the NYMEX futures options market. Conditioning on expected price levels, I find that oil production companies significantly reduce the number of wells they drill when expected price volatility is high. I conclude with "Daylight Time and Energy: Evidence from an Australian Experiment," co-authored with Hendrik Wolff. This chapter assesses DST's impact on electricity demand using a quasi-experiment in which parts of Australia extended DST in 2000 to facilitate the Sydney Olympics. We show that the extension did not reduce overall electricity consumption, but did cause a substantial intra-day shift in demand consistent with activity patterns that are tied to the clock rather than sunrise and sunset.
Impact of daylight saving time on road traffic collision risk: a systematic review
Carey, Rachel N; Sarma, Kiran M
2017-01-01
Background Bills have been put forward in the UK and Republic of Ireland proposing a move to Central European Time (CET). Proponents argue that such a change will have benefits for road safety, with daylight being shifted from the morning, when collision risk is lower, to the evening, when risk is higher. Studies examining the impact of daylight saving time (DST) on road traffic collision risk can help inform the debate on the potential road safety benefits of a move to CET. The objective of this systematic review was to examine the impact of DST on collision risk. Methods Major electronic databases were searched, with no restrictions as to date of publication (the last search was performed in January 2017). Access to unpublished reports was requested through an international expert group. Studies that provided a quantitative analysis of the effect of DST on road safety-related outcomes were included. The primary outcomes of interest were road traffic collisions, injuries and fatalities. Findings Twenty-four studies met the inclusion criteria. Seventeen examined the short-term impact of transitions around DST and 12 examined long-term effects. Findings from the short-term studies were inconsistent. The long-term findings suggested a positive effect of DST. However, this cannot be attributed solely to DST, as a range of road collision risk factors vary over time. Interpretation The evidence from this review cannot support or refute the assertion that a permanent shift in light from morning to evening will have a road safety benefit. PMID:28674131
From dark to bright: novel daylighting applications in solid state lighting
NASA Astrophysics Data System (ADS)
Adler, Helmar G.
2011-10-01
The term "daylighting" is used in various ways, on one hand in a more architectural sense, i.e. using existing daylight to illuminate spaces, and on the other, more recently, for using light sources to replicate daylight. The emergence of solid state lighting (SSL) opens up a large number of new avenues for daylighting. SSL allows innovative controllability of intensity and color for artificial light sources that can be advantageously applied to daylighting. With the assistance of these new technologies the combination of natural and artificial lighting could lead to improvements in energy savings and comfort of living beings. Thus it is imperative to revisit or even improve daylighting research so that building networks of the future with their sensor, energy (e.g. HVAC) and lighting requirements can benefit from the emerging capabilities. This paper will briefly review existing daylighting concepts and technology and discuss new ideas. An example of a tunable multi-color SSL system will be shown.
Trampoline-associated injuries are more common in children in spring.
Yule, Michael S; Krishna, Sanjeev; Rahiri, Jamie-Lee; Hill, Andrew G
2016-06-10
Trampoline use is a popular pastime amongst children in New Zealand, and has many advantages for child development. However, recent reports claim that trampoline-associated injuries are still highly prevalent. In order to help prevent these injuries in the future, this study aims to provide more up-to-date epidemiological information in children, with emphasis on the time of year that injuries most commonly occur. A retrospective review was carried out utilising a prospective maintained trauma database. The database was searched electronically for injuries involving trampolines in children aged 0-15 years. Patient demographics and information regarding month of injury, injury type and management were extracted. There were 344 admissions to hospital for trampoline-related injuries between June 2000 and January 2015. Injuries were uncommon in winter, but rose in spring and summer. Fracture of the radius and/or ulna was the most common injury (34.0%), followed by humeral fracture (32.0%). The peak incidence of trampoline-related injuries occurred around the beginning of spring daylight savings time each year. This could therefore prove an opportune time to remind children and parents about trampoline safety at the same time as daylight savings reminders.
Daylight savings time and myocardial infarction.
Sandhu, Amneet; Seth, Milan; Gurm, Hitinder S
2014-01-01
Prior research has shown a transient increase in the incidence of acute myocardial infarction (AMI) after daylight savings time (DST) in the spring as well as a decrease in AMI after returning to standard time in the fall. These findings have not been verified in a broader population and if extant, may have significant public health and policy implications. We assessed changes in admissions for AMI undergoing percutaneous coronary intervention (PCI) in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) database for the weeks following the four spring and three fall DST changes between March 2010 and September 2013. A negative binomial regression model was used to adjust for trend and seasonal variation. There was no difference in the total weekly number of PCIs performed for AMI for either the fall or spring time changes in the time period analysed. After adjustment for trend and seasonal effects, the Monday following spring time changes was associated with a 24% increase in daily AMI counts (p=0.011), and the Tuesday following fall changes was conversely associated with a 21% reduction (p=0.044). No other weekdays in the weeks following DST changes demonstrated significant associations. In the week following the seasonal time change, DST impacts the timing of presentations for AMI but does not influence the overall incidence of this disease.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
...-2504B currently reads ``0600 to 2400 PST, daily'' and the time of designation for R-2530 currently reads...-2400 local time, daily, during both standard time and daylight saving time periods and for R-2530 is... time of designation is amended to read ``0600 to 2400 local time, daily'' for R-2504A and R-2504B and...
Hertog, W; Llenas, A; Carreras, J
2015-11-30
This article demonstrates the benefits of complementing a daylight-lit environment with a spectrally tunable illumination system. The spectral components of daylight present in the room are measured by a low-cost miniature spectrophotometer and processed through a number of optimization algorithms, carefully trading color fidelity for energy efficiency. Spectrally-tunable luminaires provide only those wavelengths that ensure that either the final illumination spectrum inside the room is kept constant or carefully follows the dynamic spectral pattern of natural daylight. Analyzing the measured data proves that such a hybrid illumination system brings both unprecendented illumination quality and significant energy savings.
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2011 CFR
2011-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2012 CFR
2012-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2014 CFR
2014-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
17 CFR 260.0-5 - Business hours of the Commission.
Code of Federal Regulations, 2013 CFR
2013-04-01
...., Washington, DC 20549, is open each day, except Saturdays, Sundays and federal holidays, from 9 a.m. to 5:30 p... federal holidays, from 8 a.m. to 5:30 p.m., Eastern Standard Time or Eastern Daylight Saving Time.... 18, 1993, as amended at 65 FR 24802, Apr. 27, 2000; 68 FR 25800, May 13, 2003; 73 FR 32228, June 5...
Daylighting in the workplace: Two new buildings offer a guiding light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackaway, A.; Littler, J.
1996-10-01
As environmental pressures intensify and energy efficiency remains paramount, there has been renewed interest in daylighting the workplace. Interestingly, daylighting`s resurgence is being furthered by mounting evidence of occupant dissatisfaction with predominantly electrically-lit offices, and two recent reports support growing concern that the lack of daylighting in these interiors has led not only to unhappy workers, but to potentially significant reductions in workplace productivity. Clearly pressure is mounting on designers to produce buildings responding to these concerns, and as the role of precedents in the evolution of design practice is unquestioned, demand has been increasing for publication of office-based daylightingmore » case studies. In an attempt to address this need, this paper examines two recently completed British buildings in which daylight has explicitly informed the architecture, and although data concerning the resulting energy savings is not yet available, these projects currently offer the design community two excellent examples of workplace daylighting where compelling visual environments are generating noteworthy occupant satisfaction.« less
ERIC Educational Resources Information Center
Grocoff, Paul N.
This report examines both electric lighting and daylighting, listing criteria to determine the correct equipment for a school renovation or building project. Specific topics examine use of prismatic lenses; parabolic louvers; and indirect lighting, including the cost savings of using indirect lighting. The report indicates there is no clear answer…
Impact of daylight saving time on road traffic collision risk: a systematic review.
Carey, Rachel N; Sarma, Kiran M
2017-07-02
Bills have been put forward in the UK and Republic of Ireland proposing a move to Central European Time (CET). Proponents argue that such a change will have benefits for road safety, with daylight being shifted from the morning, when collision risk is lower, to the evening, when risk is higher. Studies examining the impact of daylight saving time (DST) on road traffic collision risk can help inform the debate on the potential road safety benefits of a move to CET. The objective of this systematic review was to examine the impact of DST on collision risk. Major electronic databases were searched, with no restrictions as to date of publication (the last search was performed in January 2017). Access to unpublished reports was requested through an international expert group. Studies that provided a quantitative analysis of the effect of DST on road safety-related outcomes were included. The primary outcomes of interest were road traffic collisions, injuries and fatalities. Twenty-four studies met the inclusion criteria. Seventeen examined the short-term impact of transitions around DST and 12 examined long-term effects. Findings from the short-term studies were inconsistent. The long-term findings suggested a positive effect of DST. However, this cannot be attributed solely to DST, as a range of road collision risk factors vary over time. The evidence from this review cannot support or refute the assertion that a permanent shift in light from morning to evening will have a road safety benefit. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Daylight savings time and myocardial infarction
Sandhu, Amneet; Seth, Milan; Gurm, Hitinder S
2014-01-01
Background Prior research has shown a transient increase in the incidence of acute myocardial infarction (AMI) after daylight savings time (DST) in the spring as well as a decrease in AMI after returning to standard time in the fall. These findings have not been verified in a broader population and if extant, may have significant public health and policy implications. Methods We assessed changes in admissions for AMI undergoing percutaneous coronary intervention (PCI) in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) database for the weeks following the four spring and three fall DST changes between March 2010 and September 2013. A negative binomial regression model was used to adjust for trend and seasonal variation. Results There was no difference in the total weekly number of PCIs performed for AMI for either the fall or spring time changes in the time period analysed. After adjustment for trend and seasonal effects, the Monday following spring time changes was associated with a 24% increase in daily AMI counts (p=0.011), and the Tuesday following fall changes was conversely associated with a 21% reduction (p=0.044). No other weekdays in the weeks following DST changes demonstrated significant associations. Conclusions In the week following the seasonal time change, DST impacts the timing of presentations for AMI but does not influence the overall incidence of this disease. PMID:25332784
Microcomputer-controlled world time display for public area viewing
NASA Astrophysics Data System (ADS)
Yep, S.; Rashidian, M.
1982-05-01
The design, development, and implementation of a microcomputer-controlled world clock is discussed. The system, designated international Time Display System (ITDS), integrates a Geochron Calendar Map and a microcomputer-based digital display to automatically compensate for daylight savings time, leap year, and time zone differences. An in-depth technical description of the design and development of the electronic hardware, firmware, and software systems is provided. Reference material on the time zones, fabrication techniques, and electronic subsystems are also provided.
Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birru, Dagnachew; Wen, Yao-Jung; Rubinstein, Francis M.
2013-10-28
This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach tomore » determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.« less
Aftermath of World Trade Center Attack
NASA Technical Reports Server (NTRS)
2002-01-01
This true-color image was taken by the Enhanced Thematic Mapper Plus (ETM+) aboard the Landsat 7 satellite on September 12, 2001, at roughly 11:30 a.m. Eastern Daylight Savings Time. Visit the NASA home page for photos from the space station and MODIS, and GlobalSecurity.org for images from other satellites. Image courtesy USGS Landsat 7 team, at the EROS Data Center.
Accident rates and the impact of daylight saving time transitions.
Robb, David; Barnes, Thomas
2018-02-01
One-third of nations have adopted some form of Daylight Saving Time (DST). Associated costs and benefits include impacts on accident rates. Using data from 12.6 million accident claims in New Zealand during 2005-2016, we model accident rates as a function of various date-based predictors including days before/after the start and end of DST, holidays, day of week, and month of year. This is the first study to consider multiple accident categories (Road, Work, Falls and Home & Community), and the first in the southern hemisphere. The start of DST is associated with significantly higher rates of road accidents (first day +16% and second day +12%). Evidence that accident rates for Falls and Home & Community decline (increase) prior to the start (end) of DST suggest potential behavioural adaption from anticipating the change. While Work accidents show limited impact from DST changes, they exhibit a significant decline over the course of the week (Friday 13% lower than Monday), whereas Road accidents exhibit a significant increase (Friday 19% higher than Monday). Our results have implications for both DST implementation and policy. Copyright © 2017 Elsevier Ltd. All rights reserved.
The NIST Internet time service
NASA Astrophysics Data System (ADS)
Levine, Judah
1994-05-01
We will describe the NIST Network Time Service which provides time and frequency information over the Internet. Our first time server is located in Boulder, Colorado, a second backup server is under construction there, and we plan to install a third server on the East Coast later this year. The servers are synchronized to UTC(NIST) with an uncertainty of about 0.8 ms RMS and they will respond to time requests from any client on the Internet in several different formats including the DAYTIME, TIME and NTP protocols. The DAYTIME and TIME protocols are the easiest to use and are suitable for providing time to PC's and other small computers. In addition to UTC(NIST), the DAYTIME message provides advance notice of leap seconds and of the transitions to and from Daylight Saving Time. The Daylight Saving Time notice is based on the US transition dates of the first Sunday in April and the last one in October. The NTP is a more complex protocol that is suitable for larger machines; it is normally run as a 'daemon' process in the background and can keep the time of the client to within a few milliseconds of UTC(NIST). We will describe the operating principles of various kinds of client software ranging from a simple program that queries the server once and sets the local clock to more complex 'daemon' processes (such as NTP) that continuously correct the time of the local clock based on periodic calibrations.
The NIST Internet time service
NASA Technical Reports Server (NTRS)
Levine, Judah
1994-01-01
We will describe the NIST Network Time Service which provides time and frequency information over the Internet. Our first time server is located in Boulder, Colorado, a second backup server is under construction there, and we plan to install a third server on the East Coast later this year. The servers are synchronized to UTC(NIST) with an uncertainty of about 0.8 ms RMS and they will respond to time requests from any client on the Internet in several different formats including the DAYTIME, TIME and NTP protocols. The DAYTIME and TIME protocols are the easiest to use and are suitable for providing time to PC's and other small computers. In addition to UTC(NIST), the DAYTIME message provides advance notice of leap seconds and of the transitions to and from Daylight Saving Time. The Daylight Saving Time notice is based on the US transition dates of the first Sunday in April and the last one in October. The NTP is a more complex protocol that is suitable for larger machines; it is normally run as a 'daemon' process in the background and can keep the time of the client to within a few milliseconds of UTC(NIST). We will describe the operating principles of various kinds of client software ranging from a simple program that queries the server once and sets the local clock to more complex 'daemon' processes (such as NTP) that continuously correct the time of the local clock based on periodic calibrations.
NASA Astrophysics Data System (ADS)
Ludman, Jacques E.; Riccobono, Juanita R.; Savant, Gajendra D.; Jannson, Joanna L.; Campbell, Eugene W.; Hall, Robyn
1995-09-01
Daylighting techniques are an effective means of reducing both lighting and cooling costs; however, many of the standard techniques have flaws which reduce their effectiveness. Daylighting holograms are an efficient and effective method for diffracting sunlight up onto the ceiling, deep in a room, without diffracting the light at eye-level. They need only cover the top half of a window to produce significant energy savings. They may be used as part of a new glazing system or as a retrofit to existing windows. These holograms are broadband and are able to passively track the movement of the sun across the sky, throughout the day and year.
Does the transition into daylight saving time really cause partial sleep deprivation?
Toth Quintilham, Manoel Carlos; Adamowicz, Taísa; Pereira, Erico Felden; Pedrazzoli, Mario; Louzada, Fernando Mazzilli
2014-01-01
To identify possible changes in the sleep patterns according to chronotype in undergraduate students during the daylight saving time (DST) transition. A total of 378 students answered the Morningness-Eveningness Questionnaire (MEQ) to determine their chronotype and kept a diary about sleep-wake schedules 1 week before and after the DST transition. Oral mucosal cell samples were collected for genetic analysis. After the DST transition, intermediate types (I-types) delayed bedtime and increased their time in bed and all groups delayed their wake-up time. All groups presented a shorter phase angle between sunset and the bedtime after the DST transition. On the other hand, only E-types showed a tendency to reduce the phase angle between sunrise and wake-up time, while I-types and M-types kept the same phase angles between sunrise and wake-up time after the DST transition. The polymorphisms in the human genes CLOCK and PER3 were not associated with individual differences in sleep patterns, nor were they associated with an adjustment to the DST transition. Under the new set of social times determined by DST, the adjustment was only partial. I-types delayed bedtime and all groups delayed their wake-up times after the beginning of DST. Consequently, the time in bed after the DST transition was not reduced; Morning (M-types) and Evening-types (E-types) kept the same time in bed and I-types showed an increase on it.
Solar Glazing Tips for School Construction
ERIC Educational Resources Information Center
Smith, Jonathan
2012-01-01
Glazing can be optimized to enhance passive solar heating and daylight harvesting by exceeding the prescriptive limits of the energy code. This savings can be garnered without the high cost of external overhangs or expensive glazing products. The majority of savings from solar glazing are attributable to the increase in solar heating and…
HORIZONTAL HYBRID SOLAR LIGHT PIPE: AN INTEGRATED SYSTEM OF DAYLIGHT AND ELECTRIC LIGHT
This project will test the feasibility of an advanced energy efficient perimeter lighting system that integrates daylighting, electric lighting, and lighting controls to reduce electricity consumption. The system is designed to provide adequate illuminance levels in deep-floor...
Muñoz, Ricardo C
2012-06-01
Daylight saving time (DST) is a common practice in many countries, in which Official Time (OT) is abruptly shifted 1 hour with respect to solar time on two occasions every year (in fall and spring). All anthropogenic emitting processes tied to OT like job and school commuting traffic, abruptly change in this moment their timing with respect to solar time, inducing a sudden shift between emissions and the meteorological factors that control the dispersion and transport of air pollutants. Analyzing 13 years of hourly particulate matter (PM10) concentrations measured in Santiago, Chile, we demonstrate that the DST practice has observable non-trivial effects in the PM10 diurnal cycle. The clearest impact is in the morning peak of PM10 during the fall DST change, which occurs later and has on average a significant smaller magnitude in the days after the DST change as compared to the days before it. This decrease in magnitude is most remarkable because it occurs in a period of the year when overall PM10 concentrations increase due to generally worsening of the dispersion conditions. Results are shown for seven monitoring stations around the city, and for the fall and spring DST changes. They show clearly the interplay of emissions and meteorology in conditioning urban air pollution problems, highlighting the role of the morning and evening transitions of the atmospheric boundary layer in shaping the diurnal pattern of urban air pollutant concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Eleanor S.; Thanachareonkit, Anothai; Touzani, Samir
The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.
NASA Astrophysics Data System (ADS)
Ekasiwi, S. N. N.; Antaryama, I. G. N.; Krisdianto, J.; Ulum, M. S.
2018-03-01
Classrooms in educational buildings require certain lighting requirements to serve teaching and learning activities during daytime. The most typical design is double sided opening in order to get good daylight distribution in the classroom. Using artificial light is essential to contribute the worse daylight condition. A short observation indicates that during the lecture time the light turned on, even in the daytime. That might result in wasting electrical energy. The aim of the study is to examine the type of classroom, which perform comfortable lighting environment as well as saving energy. This paper reports preliminary results of the study obtained from field observation and measurements. The use of energy and usage pattern of artificial lighting during the lecture is recorded and then the data evaluated to see the suitability of existing energy use to building energy standards. The daylighting design aspects have to be the first consideration. However, the similarity in WWR of the classroom, the Daylight Factor (DF) may differ. It depends on the room depth. The similarity of the increase of WWR and Ratio of openings to floor area do not directly correspond to the increase of DF. The outdoor condition of larger daylight access and the room depth are the influencing factors. Despite the similarity of physical type, usage pattern of the classroom imply the use of electrical energy for lighting. The results indicate the factors influencing lighting energy performance in correlation to their typologies
Window performance and building energy use: Some technical options for increasing energy efficiency
NASA Astrophysics Data System (ADS)
Selkowitz, Stephen
1985-11-01
Window system design and operation has a major impact on energy use in buildings as well as on occupants' thermal and visual comfort. Window performance will be a function of optical and thermal properties, window management strategies, climate and orientation, and building type and occupancy. In residences, heat loss control is a primary concern, followed by sun control in more southerly climates. In commercial buildings, the daylight provided by windows may be the major energy benefits but solar gain must be controlled so that increased cooling loads do not exceed daylighting savings. Reductions in peak electrical demand and HVAC system size may also be possible in well-designed daylighted buildings.
Literature Review of the Effects of Natural Light on Building Occupants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, L.; Torcellini, P.
This paper presents summary findings from a literature search of the term ''daylighting''-using natural light in a building to offset or replace electric lighting. According to the Department of Energy's Office of Building Technology, State and Community Programs 2000 BTS Core Databook, in 1998, commercial buildings consumed 32% of the total electricity in the United States, of which more than one-third went to lighting. Using daylighting systems and turning off the lights will help reduce this energy load. Electrical lighting adds to both the electrical and cooling loads in a commercial building. Utility costs can be decreased when daylighting ismore » properly designed to replace electrical lighting. Along with the importance of energy savings, studies have demonstrated the non-energy-related benefits of daylighting. We compiled the data from books, periodicals, Internet articles, and interviews. The books, periodicals, and Internet articles provided the background information used to identify the main subjects of the paper. The interviews provided us with details related to specific buildings and companies that have integrated daylighting into their buildings.« less
Daylight characterization through vision-based sensing of lighting conditions in buildings
NASA Astrophysics Data System (ADS)
di Dio, Joseph, III
A new method for describing daylight under unknown weather conditions, as captured in images of a room, is proposed. This method considers pixel brightness information to be a linear combination of diffuse and directional light components, as received by a web cam from the walls and ceiling of an occupied office. The nature of these components in each image is determined by building orientation, room geometry, neighboring structures and the position of the sun. Considering daylight in this manner also allows for an estimation of the sky conditions at a given instant to be made, and presents a means to uncover seasonal trends in the behavior of light simply by monitoring the brightness variations of points on the walls and ceiling. Significantly, this daylight characterization method also allows for an estimation of the illumination level on a target surface to be made from image data. Currently, illumination at a target surface is estimated through the use of a ceiling-mounted photosensor, as part of a lighting control system, in the hopes of achieving a suitable balance between daylight and electrical lighting in a space. Improving the ability of a sensor to estimate the illumination is of great importance to those who wish to minimize unnecessary energy consumption, as a significant percentage of all U.S. electricity is currently consumed by light fixtures. A photosensor detects light that falls on its location, which does not necessarily correspond in a fixed manner to the light level on the target areas that the photosensor is meant to monitor. Additionally, a photosensor cannot discern variations in light distribution across a room, which often occur with daylight. By considering pixel brightness information to be a linear combination of diffuse and directional light components at selected pixels in an image, information about the light reaching these pixels can be extracted from observed patterns of brightness, under different light conditions. In this manner, each pixel provides information about the light field at its corresponding point in the room, and thus each pixel can be considered to behave as if it were a remote photosensor. By using multiple pixel readings in lieu of a single photosensor reading of a given light condition, an improved assessment of the illumination level on a target surface can been achieved. It is shown that on average, the camera-based method was approximately 25% more accurate in estimating illuminance in the test room than was a simulated ceiling-mounted photosensor. It is hoped that the methodology detailed here will aid in the eventual development of a camera-based daylight characterization sensor for use in lighting control systems, so that the potential for enhanced energy savings can be realized.
Development of Design Guidance for K-12 Schools from 30% to 50% Energy Savings: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pless, S.; Torcellini, P.; Long, N.
2008-07-01
This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating.
Technical-economic feasibility of orbiting sunlight reflectors
NASA Astrophysics Data System (ADS)
Alferov, Z.; Minin, V.
1986-02-01
The use of deflectors in orbit as a means of providing artificial illumination is examined. Considerations of technical and economic feasibility are addressed. Three main areas of application are distinguished: reflecting sunlight onto the surface of the Earth; concentration of the flow of solar energy on an orbiting receiver; and retransmission of optical radiation. The advantages of the artificial Earth illumination application of the orbiting reflector scheme in terms of energy savings in lighting cities, and additional daylight time for critical periods of farming operations are discussed.
Fatal accidents following changes in daylight savings time: the American experience.
Varughese; Allen
2001-01-01
Objective: This study examines specific hypotheses that both sleep loss and behavioral changes occurring with the time shifts for Daylight Savings Time (DST) significantly effect the number of fatal traffic accidents in the United States of America.Background: It has been reported that there is a significant increase in the number of automobile accidents in the spring shift to DST due to the loss of 1 h of sleep. But the extra hour gained at night with the shift from DST in the fall has been variably reported to be associated with increases and decreases in the number of automobile accidents which may reflect either behavioral anticipation with an extended late night prior to the change or the benefit of extra sleep after the change.Methods: Data from 21 years of United States' fatal automobile accidents were gathered. The mean number of accidents on the days at the time of the shifts (Saturday, Sunday and Monday) was compared to the average of the corresponding mean number of accidents on the matching day of the weeks preceding and following the shift. This was repeated for each DST shift. The number of accidents for a particular shift was also correlated with the year of the accidents.Results: There was a significant increase in accidents for the Monday immediately following the spring shift to DST (t=1.92, P=0.034). There was also a significant increase in number of accidents on the Sunday of the fall shift from DST (P<0.002). No significant changes were observed for the other days. A significant negative correlation with the year was found between the number of accidents on the Saturdays and Sundays but not Mondays.Conclusions: The sleep deprivation on the Monday following shift to DST in the spring results in a small increase in fatal accidents. The behavioral adaptation anticipating the longer day on Sunday of the shift from DST in the fall leads to an increased number of accidents suggesting an increase in late night (early Sunday morning) driving when traffic related fatalities are high possibly related to alcohol consumption and driving while sleepy. Public health educators should probably consider issuing warnings both about the effects of sleep loss in the spring shift and possible behaviors such as staying out later, particularly when consuming alcohol in the fall shift. Sleep clinicians should be aware that health consequences from forced changes in the circadian patterns resulting from DST come not only from physiological adjustments but also from behavioral responses to forced circadian changes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, L.O.; Lee, E.S.; Papmichael, K.M.
1994-03-01
We present results from the design and evaluation of three advanced daylighting systems: a light shelf, a light pipe, and a skylight. These systems use optical films and an optimized geometry to passively intercept and redirect sunlight further into the building. The objectives of these designs are to increase daylighting illuminance levels at distances of 4.6-9.1 m (15--30 ft) from the window, and to improve the uniformity of the daylight distribution and the luminance gradient across the room under variable sun and sky conditions throughout the year. The designs were developed through a series of computer-assisted ray-tracing studies, photometric measurements,more » and observations using physical scale models. Comprehensive sets of laboratory measurements in combination with analytical routines were then used to simulate daylight performance for any solar position. Results show increased daylight levels and an improved luminance gradient throughout the year -- indicating that lighting energy consumption and cooling energy due of lighting can be substantially reduced with improvements to visual comfort. Future development of the designs may further improve the daylighting performance of these systems.« less
ERIC Educational Resources Information Center
Shimm, Jon
2001-01-01
Discusses how incorporating energy-efficient features into residence halls can save money and make students' campus experience more enjoyable. Use of heat-recovery systems, low-impact lighting, and natural daylighting are explored as are ideas to consider for future residence hall construction projects or renovations. (GR)
NASA Astrophysics Data System (ADS)
Linhart, Friedrich; Wittkopf, Stephen K.; Münch, Mirjam; Scartezzini, Jean-Louis
2009-08-01
Making daylight more available in buildings is highly desirable for reasons of energy efficiency, visual comfort, occupant well-being and health. The Anidolic Integrated Ceiling (AIC) is a highly efficient daylighting system, designed to gather and redirect daylight from the outside of a building into its interior with minimal losses. The reflective coating materials used within AICs have a major impact on the optical efficiency of such systems. The first part of our article presents a new computer model of an AIC consisting of more than 30 distinct components. We discuss on which of them the use of expensive, highly reflective coatings makes the most sense. We conclude that coating the component "Anidolic element 1" is always a good choice and that considerable financial savings can be obtained by following an appropriate optimization sequence.The second part of our article discusses chronobiological properties of Anidolic Daylighting Systems (ADS). We recorded daytime irradiance values for several weeks from March to May 2009 in an experimental office setup in our laboratory using a portable digital spectroradiometer. Our results showed to which extent different sky conditions influenced daylight exposure of office workers in an ADS-equipped office room. We conclude that for the tested ADS-equipped office room, daylight supply can be considered largely sufficient during long periods on most working days. However, complementary artificial lighting with blue-enriched polychromatic fluorescent tubes might be useful on days with predominantly overcast skies as well as before 09:00 and after 16:30 on all days.
Development of Design Guidance for K-12 Schools: From 30% to 50% Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pless, S.; Torcellini, P.; Long, N.
2008-01-01
This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 Schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings (1999 and 2004 versions). Exhaustive simulations were run to create packages of energy design solutions available over a wide range of K-12 schools and climates. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating. We document and discuss the energy modeling performed to demonstrate that themore » recommendations will result in at least 30% energy savings over ASHRAE 90.1-1999 and ASHRAE 90.1-2004. Recommendations are evaluated based on the availability of daylighting for the school and by the type of HVAC system. Compared to the ASHRAE 90.1-1999 baseline, the recommendations result in more than 30% savings in all climate zones for both daylit and nondaylit elementary, middle, and high schools with a range of HVAC system types. These recommendations have been included in the Advanced Energy Design Guide for K-12 School Buildings. Compared to the more stringent ASHRAE 90.1-2004 baseline, the recommendations result in more than 30% savings in all climate zones, for only the daylit elementary, middle, and high schools, with a range of HVAC system types. To inform the future development of recommendations for higher level of energy savings, we analyzed a subset of recommendations to understand which energy efficiency technologies would be needed to achieve 50% energy savings.« less
A SIEPON based transmitter sleep mode energy-efficient mechanism in EPON
NASA Astrophysics Data System (ADS)
Nikoukar, AliAkbar; Hwang, I.-Shyan; Wang, Chien-Jung; Ab-Rahman, Mohammad Syuhaimi; Liem, Andrew Tanny
2015-06-01
The main energy consumption in computer networks is the access networks. The passive optical network (PON) has the least energy consumption among access network technologies. In addition, the time division multiplexing (TDM) Ethernet PON (EPON) is one of the best candidates to improve energy consumption by time utilization. The optical network unit (ONU) can utilize the time and save the energy in the EPON by turning off its transmitter/receiver when there is no upstream/downstream traffic. The ITU-T and IEEE organizations are published standards for energy-saving in the TDM-PON. Although their standards provide the framework to accomplish the energy-saving, the algorithms/criteria to generate events to accommodate various operational policies, time to wake up, parameter values for timers are out of scope of the standards. Many studies have proposed schemes for energy-saving in TDM-PON to achieve maximum energy saving. Even so, these schemes increase the mean packet delay and consequently, reduce the quality of service (QoS). In this paper, first we take a look to the state of the art for PON energy-saving. Additionally, a mechanism based on SIEPON standard in EPON with new components in the ONUs and optical line terminal (OLT) is proposed to save the transmitter energy and guarantee QoS. The proposed mechanism follows the SIEPON standard, considers the QoS first, and then saves the energy as far as possible. The ONU sleep controller unit (OSC) and green dynamic bandwidth allocation (GDBA) are used to calculate the ONU transmitter sleep (Tx) duration and grant the proper time to the ONUs. Simulation results show that the proposed energy-saving mechanism not only promises the QoS performance in terms of mean packet delay, packet loss, throughput, and jitter, but also saves energy in different maximum cycle times.
Lighting the School of the Future.
ERIC Educational Resources Information Center
Clanton, Nancy
1999-01-01
Discusses the Austin Independent School District's (Texas) school redesign efforts to allow more daylight in its schools, increase the students' comfort and productivity, and lower utility costs. Return on investment potential from savings in maintenance, replacement, and productivity of the school are highlighted. (GR)
Automatic target detection using binary template matching
NASA Astrophysics Data System (ADS)
Jun, Dong-San; Sun, Sun-Gu; Park, HyunWook
2005-03-01
This paper presents a new automatic target detection (ATD) algorithm to detect targets such as battle tanks and armored personal carriers in ground-to-ground scenarios. Whereas most ATD algorithms were developed for forward-looking infrared (FLIR) images, we have developed an ATD algorithm for charge-coupled device (CCD) images, which have superior quality to FLIR images in daylight. The proposed algorithm uses fast binary template matching with an adaptive binarization, which is robust to various light conditions in CCD images and saves computation time. Experimental results show that the proposed method has good detection performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Lei; Holden, Jacob; Gonder, Jeffrey D
The green routing strategy instructing a vehicle to select a fuel-efficient route benefits the current transportation system with fuel-saving opportunities. This paper introduces a navigation API route fuel-saving evaluation framework for estimating fuel advantages of alternative API routes based on large-scale, real-world travel data for conventional vehicles (CVs) and hybrid electric vehicles (HEVs). The navigation APIs, such Google Directions API, integrate traffic conditions and provide feasible alternative routes for origin-destination pairs. This paper develops two link-based fuel-consumption models stratified by link-level speed, road grade, and functional class (local/non-local), one for CVs and the other for HEVs. The link-based fuel-consumption modelsmore » are built by assigning travel from a large number of GPS driving traces to the links in TomTom MultiNet as the underlying road network layer and road grade data from a U.S. Geological Survey elevation data set. Fuel consumption on a link is calculated by the proposed fuel consumption model. This paper envisions two kinds of applications: 1) identifying alternate routes that save fuel, and 2) quantifying the potential fuel savings for large amounts of travel. An experiment based on a large-scale California Household Travel Survey GPS trajectory data set is conducted. The fuel consumption and savings of CVs and HEVs are investigated. At the same time, the trade-off between fuel saving and time saving for choosing different routes is also examined for both powertrains.« less
Power, Politics and Purchasing.
ERIC Educational Resources Information Center
Moore, Deborah P.
2000-01-01
Explores the overlapping of energy efficiency, budget-cutting, and facility needs in K-12 schools. Utilities expenditures in schools are discussed for electricity and natural gas as are energy-saving alternatives such as daylighting, solar energy, wind production of power, and geothermal energy. Sources for further information conclude the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This LEED Platinum home was built on the site of a 60-year-old bungalow that was demolished. It boasts views of Candlewood Lake, a great deal of daylight, and projected annual energy savings of almost $3,000. This home was awarded a 2013 Housing Innovation Award in the custom builder category.
NASA Astrophysics Data System (ADS)
Amado, L.; Osma, G.; Villamizar, R.
2016-07-01
This paper presents the modelling of lighting behaviour of a hybrid lighting system - HLS in inner spaces for tropical climate. HLS aims to mitigate the problem of high electricity consumption used by artificial lighting in buildings. These systems integrate intelligently the daylight and artificial light through control strategies. However, selection of these strategies usually depends on expertise of designer and of available budget. In order to improve the selection process of the control strategies, this paper analyses the Electrical Engineering Building (EEB) case, initially modelling of lighting behaviour is established for the HLS of a classroom and an office. This allows estimating the illuminance level of the mixed lighting in the space, and energy consumption by artificial light according to different lighting control techniques, a control strategy based on occupancy and a combination of them. The model considers the concept of Daylight Factor (DF) for the estimating of daylight illuminance on the work plane for tropical climatic conditions. The validation of the model was carried out by comparing the measured and model-estimated indoor illuminances.
Incidence of myocardial infarction with shifts to and from daylight savings time.
Jiddou, Monica R; Pica, Mark; Boura, Judy; Qu, Lihua; Franklin, Barry A
2013-03-01
Modulators of normal bodily functions such as the duration and quality of sleep might transiently influence cardiovascular risk. The transition to daylight savings time (DST) has been associated with a short-term increased incidence ratio (IR) of acute myocardial infarction (AMI). The present retrospective study examined the IR of AMIs that presented to our hospitals the week after DST and after the autumn switch to standard time, October 2006 to April 2012, with specific reference to the AMI type. Our study population (n = 935 patients; 59% men, 41% women) was obtained from the electronic medical records of the Royal Oak and Troy campuses of the Beaumont Hospitals in Michigan. Overall, the frequency of AMI was similar in the spring and autumn, 463 (49.5%) and 472 (50.5%), respectively. The IR for the first week after the spring shift was 1.17 (95% confidence interval 1.00 to 1.36). After the transition from DST in the autumn, the IR for the same period was lower, but not significantly different, 0.99 (95% confidence interval 0.85 to 1.16). Nevertheless, the greatest increase in AMI occurred on the first day (Sunday) after the spring shift to DST (1.71, 95% confidence interval 1.09 to 2.02; p <0.05). Also, a significantly greater incidence was found of non-ST-segment myocardial infarction after the transition to DST in the study group compared with that in the control group (p = 0.022). In conclusion, these data suggest that shifts to and from DST might transiently affect the incidence and type of acute cardiac events, albeit modestly. Copyright © 2013 Elsevier Inc. All rights reserved.
Transition into and out of daylight saving time and spontaneous delivery: a population-based study
László, Krisztina D; Cnattingius, Sven; Janszky, Imre
2016-01-01
Objective To investigate whether the circadian rhythm disruption following the transition into and out of daylight saving time (DST) is associated with an increased risk of spontaneous delivery. Design We compared the number of spontaneous deliveries in the Swedish Medical Birth Register during the week after the change to and the week after the change from DST (exposure periods) with the average number of spontaneous deliveries in the control period, defined as the week before and the week after each exposure period. Setting Sweden, 1993–2006. Primary and secondary outcome measures The primary outcomes were the weekly and the daily number of spontaneous deliveries in the exposure and the control periods. In secondary analyses we also compared the mean length of pregnancy of the women with spontaneous deliveries in the exposure and control periods. Results The number of deliveries during the week after the transition into or out of DST was similar to that in the comparison period (18 519 observed vs 18 434 expected in case of the spring shift and 19 073 observed vs 19 122 expected in case of the autumn shift); the corresponding incidence ratio and 95% CIs were 1.005 (0.990 to 1.019) and 0.997 (0.983 to 1.012), respectively. There were no differences in the length of gestation of the deliveries in the exposure and the control periods. Conclusions Our results do not support the hypothesis that a minor circadian rhythm disruption is associated with an increased short-term risk of spontaneous delivery. PMID:27630067
NASA Astrophysics Data System (ADS)
Alzoubi, Hussain Hendi
Energy consumption in buildings has recently become a major concern for environmental designers. Within this field, daylighting and solar energy design are attractive strategies for saving energy. This study seeks the integrity and the optimality of building envelopes' performance. It focuses on the transparent parts of building facades, specifically, the windows and their shading devices. It suggests a new automated method of utilizing solar energy while keeping optimal solutions for indoor daylighting. The method utilizes a statistical approach to produce mathematical equations based on physical experimentation. A full-scale mock-up representing an actual office was built. Heat gain and lighting levels were measured empirically and correlated with blind angles. Computational methods were used to estimate the power production from photovoltaic cells. Mathematical formulas were derived from the results of the experiments; these formulas were utilized to construct curves as well as mathematical equations for the purpose of optimization. The mathematical equations resulting from the optimization process were coded using Java programming language to enable future users to deal with generic locations of buildings with a broader context of various climatic conditions. For the purpose of optimization by automation under different climatic conditions, a blind control system was developed based on the findings of this study. This system calibrates the blind angles instantaneously based upon the sun position, the indoor daylight, and the power production from the photovoltaic cells. The functions of this system guarantee full control of the projected solar energy on buildings' facades for indoor lighting and heat gain. In winter, the system automatically blows heat into the space, whereas it expels heat from the space during the summer season. The study showed that the optimality of building facades' performance is achievable for integrated thermal, energy, and lighting models in buildings. There are blind angles that produce maximum energy from the photovoltaic cells while keeping indoor light within the acceptable limits that prevent undesired heat gain in summer.
Energy saving and consumption reducing evaluation of thermal power plant
NASA Astrophysics Data System (ADS)
Tan, Xiu; Han, Miaomiao
2018-03-01
At present, energy saving and consumption reduction require energy saving and consumption reduction measures for thermal power plant, establishing an evaluation system for energy conservation and consumption reduction is instructive for the whole energy saving work of thermal power plant. By analysing the existing evaluation system of energy conservation and consumption reduction, this paper points out that in addition to the technical indicators of power plant, market activities should also be introduced in the evaluation of energy saving and consumption reduction in power plant. Ttherefore, a new evaluation index of energy saving and consumption reduction is set up and the example power plant is calculated in this paper. Rresults show that after introducing the new evaluation index of energy saving and consumption reduction, the energy saving effect of the power plant can be judged more comprehensively, so as to better guide the work of energy saving and consumption reduction in power plant.
Analyzing Carbohydrate-Based Regenerative Fuel Cells as a Power Source for Unmanned Aerial Vehicles
2008-03-01
conventional means of generating electrical energy, such as turbines and internal combustion engines, in that the conventional methods normally have an...have 24 hours of daylight, this means that it must be able to store enough exergy (the total amount of energy that can theoretically be converted to...useful work, differentiated from useful energy by the efficiency of converting energy to work) to function during the time when exergy consumption is
An energy-aware routing protocol for query-based applications in wireless sensor networks.
Ahvar, Ehsan; Ahvar, Shohreh; Lee, Gyu Myoung; Crespi, Noel
2014-01-01
Wireless sensor network (WSN) typically has energy consumption restriction. Designing energy-aware routing protocol can significantly reduce energy consumption in WSNs. Energy-aware routing protocols can be classified into two categories, energy savers and energy balancers. Energy saving protocols are used to minimize the overall energy consumed by a WSN, while energy balancing protocols attempt to efficiently distribute the consumption of energy throughout the network. In general terms, energy saving protocols are not necessarily good at balancing energy consumption and energy balancing protocols are not always good at reducing energy consumption. In this paper, we propose an energy-aware routing protocol (ERP) for query-based applications in WSNs, which offers a good trade-off between traditional energy balancing and energy saving objectives and supports a soft real time packet delivery. This is achieved by means of fuzzy sets and learning automata techniques along with zonal broadcasting to decrease total energy consumption.
An Energy-Aware Routing Protocol for Query-Based Applications in Wireless Sensor Networks
Crespi, Noel
2014-01-01
Wireless sensor network (WSN) typically has energy consumption restriction. Designing energy-aware routing protocol can significantly reduce energy consumption in WSNs. Energy-aware routing protocols can be classified into two categories, energy savers and energy balancers. Energy saving protocols are used to minimize the overall energy consumed by a WSN, while energy balancing protocols attempt to efficiently distribute the consumption of energy throughout the network. In general terms, energy saving protocols are not necessarily good at balancing energy consumption and energy balancing protocols are not always good at reducing energy consumption. In this paper, we propose an energy-aware routing protocol (ERP) for query-based applications in WSNs, which offers a good trade-off between traditional energy balancing and energy saving objectives and supports a soft real time packet delivery. This is achieved by means of fuzzy sets and learning automata techniques along with zonal broadcasting to decrease total energy consumption. PMID:24696640
Parametric analysis of parameters for electrical-load forecasting using artificial neural networks
NASA Astrophysics Data System (ADS)
Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael
1997-04-01
Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.
CASI Work Plan: Calendar Year 2013
2013-02-15
reducing energy consumption in existing Army barracks using innovative heating, ventilating , and air-conditioning (HVAC) and building envelope...to enhance the effective “R-value” of insulation, thus reducing energy transfer through walls while maintaining comfortable temperatures for... consumption below ASHRAE’s goal for new facilities. This project will determine how effective the daylighting strategies are in providing adequate
Transition into and out of daylight saving time and spontaneous delivery: a population-based study.
László, Krisztina D; Cnattingius, Sven; Janszky, Imre
2016-09-14
To investigate whether the circadian rhythm disruption following the transition into and out of daylight saving time (DST) is associated with an increased risk of spontaneous delivery. We compared the number of spontaneous deliveries in the Swedish Medical Birth Register during the week after the change to and the week after the change from DST (exposure periods) with the average number of spontaneous deliveries in the control period, defined as the week before and the week after each exposure period. Sweden, 1993-2006. The primary outcomes were the weekly and the daily number of spontaneous deliveries in the exposure and the control periods. In secondary analyses we also compared the mean length of pregnancy of the women with spontaneous deliveries in the exposure and control periods. The number of deliveries during the week after the transition into or out of DST was similar to that in the comparison period (18 519 observed vs 18 434 expected in case of the spring shift and 19 073 observed vs 19 122 expected in case of the autumn shift); the corresponding incidence ratio and 95% CIs were 1.005 (0.990 to 1.019) and 0.997 (0.983 to 1.012), respectively. There were no differences in the length of gestation of the deliveries in the exposure and the control periods. Our results do not support the hypothesis that a minor circadian rhythm disruption is associated with an increased short-term risk of spontaneous delivery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
An energy saving mechanism of EPON networks for real time video transmission
NASA Astrophysics Data System (ADS)
Liu, Chien-Ping; Wu, Ho-Ting; Chiang, Yun-Ting; Chien, Shieh-Chieh; Ke, Kai-Wei
2015-07-01
Modern access networks are constructed widely by passive optical networks (PONs) to meet the growing bandwidth demand. However, higher bandwidth means more energy consumption. To save energy, a few research works propose the dual-mode energy saving mechanism that allows the ONU to operate between active and sleep modes periodically. However, such dual-mode energy saving design may induce unnecessary power consumption or packet delay increase in the case where only downstream data exist for most of the time. In this paper, we propose a new tri-mode energy saving scheme for Ethernet PON (EPON). The new tri-mode energy saving design, combining the dual-mode saving mechanism with the doze mode, allows the ONU to switch among these three modes alternatively. In the doze mode, the ONU may receive downstream data while keeping its transmitter close. Such scenario is often observed for real time video downstream transmission. Furthermore, the low packet delay of high priority upstream data can be attained through the use of early wake-up mechanism employed in both energy saving modes. The energy saving and system efficiency can thus be achieved jointly while maintaining the differentiated QoS for data with various priorities. Performance results via simulation have demonstrated the effectiveness of such mechanism.
Activity and observability of meteor showers throughout the year
NASA Astrophysics Data System (ADS)
Zimnikoval, Peter
2014-02-01
Diagrams on the poster present the activity periods of meteor showers as well as the rising and setting times of meteor shower radiants. Plotted are sunrises, sunsets and the period of twilight. It was constructed according to data from the IMO Meteor Shower Working List. More active showers are displayed in red and less active showers in green. The diagrams are calculated for geographic latitudes of 40° N, 0° and 40° S. The time scale is given as local time at the relevant zonal meridian and supplemented by local daylight saving time. The diagrams contain rounded values of solar longitude J2000. The star chart shows the radiant positions and drift of IMO meteor showers while the other diagrams display shower activity and date of maximum.
Wireless sensor and actuator networks for lighting energy efficiency and user satisfaction
NASA Astrophysics Data System (ADS)
Wen, Yao-Jung
Buildings consume more than one third of the primary energy generated in the U.S., and lighting alone accounts for approximately 30% of the energy usage in commercial buildings. As the largest electricity consumer of all building electrical systems, lighting harbors the greatest potential for energy savings in the commercial sector. Fifty percent of current energy consumption could be reduced with energy-efficient lighting management strategies. While commercial products do exist, they are poorly received due to exorbitant retrofitting cost and unsatisfactory performance. As a result, most commercial buildings, especially legacy buildings, have not taken advantage of the opportunity to generate savings from lighting. The emergence of wireless sensor and actuator network (WSAN) technologies presents an alternative that circumvents costly rewiring and promises better performance than existing commercial lighting systems. The goal of this dissertation research is to develop a framework for wireless-networked lighting systems with increased cost effectiveness, energy efficiency, and user satisfaction. This research is realized through both theoretical developments and implementations. The theoretical research aims at developing techniques for harnessing WSAN technologies to lighting hardware and control strategies. Leveraging redundancy, a sensor validation and fusion algorithm is developed for extracting pertinent lighting information from the disturbance-prone desktop-mounted photosensors. An adaptive sensing strategy optimizes the timing of data acquisition and power-hungry wireless transmission of sensory feedback in real-time lighting control. Exploiting the individual addressability of wireless-enabled luminaires, a lighting optimization algorithm is developed to create the optimal lighting that minimizes energy usage while satisfying occupants' diverse lighting preferences. The wireless-networked lighting system was implemented and tested in a number of real-life settings. A human subject study conducted in a private office concluded that the research system was competitive with the commercial lighting system with much fewer retrofitting requirements. The system implemented in a shared-space office realized a self-configuring mesh network with wireless photosensors and light actuators, and demonstrated a 50% energy savings and increased performance when harvesting daylight through windows is possible. The cost analysis revealed a reasonable payback period after the system is optimized for commercialization and confirms the marketing feasibility.
NASA Technical Reports Server (NTRS)
Plankey, B.
1981-01-01
A computer program called ECPVER (Energy Consumption Program - Verification) was developed to simulate all energy loads for any number of buildings. The program computes simulated daily, monthly, and yearly energy consumption which can be compared with actual meter readings for the same time period. Such comparison can lead to validation of the model under a variety of conditions, which allows it to be used to predict future energy saving due to energy conservation measures. Predicted energy saving can then be compared with actual saving to verify the effectiveness of those energy conservation changes. This verification procedure is planned to be an important advancement in the Deep Space Network Energy Project, which seeks to reduce energy cost and consumption at all DSN Deep Space Stations.
Way Beyond Widgets: Delivering Integrated Lighting Design in Actionable Solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myer, Michael; Richman, Eric E.; Jones, Carol C.
2008-08-17
Previously, energy-efficiency strategies for commercial spaces have focused on using efficient equipment without providing specific detailed instructions. Designs by experts in their fields are an energy-efficiency product in its own right. A new national program has developed interactive application-specific lighting designs for widespread use in four major commercial sectors. This paper will describe the technical basis for the solutions, energy efficiency and cost-savings methodology, and installations and measurement/verification to-date. Lighting designs have been developed for five types of retail stores (big box, small box, grocery, specialty market, and pharmacy) and are planned for the office, healthcare, and education sectors asmore » well. Nationally known sustainable lighting designers developed the designs using high-performance commercially available products, daylighting, and lighting controls. Input and peer review was received by stakeholders, including manufacturers, architects, utilities, energy-efficiency program sponsors (EEPS), and end-users (i.e., retailers). An interactive web tool delivers the lighting solutions and analyzes anticipated energy savings using project-specific inputs. The lighting solutions were analyzed against a reference building using the space-by-space method as allowed in the Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004) co-sponsored by the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the Illuminating Engineering Society of North America (IESNA). The results showed that the design vignettes ranged from a 9% to 28% reduction in the allowed lighting power density. Detailed control strategies are offered to further reduce the actual kilowatt-hour power consumption. When used together, the lighting design vignettes and control strategies show a modeled decrease in energy consumption (kWh) by 33% to 50% below the baseline design.« less
Control algorithms for dynamic windows for residential buildings
Firlag, Szymon; Yazdanian, Mehrangiz; Curcija, Charlie; ...
2015-09-30
This study analyzes the influence of control algorithms for dynamic windows on energy consumption, number of hours of retracted shades during daylight and shade operations. Five different control algorithms - heating/cooling, simple rules, perfect citizen, heat flow and predictive weather were developed and compared. The performance of a typical residential building was modeled with EnergyPlus. The program Widow was used to generate a Bi-Directional Distribution Function (BSDF) for two window configurations. The BSDF was exported to EnergyPlus using the IDF file format. The EMS feature in EnergyPlus was used to develop custom control algorithms. The calculations were made for fourmore » locations with diverse climate. The results showed that: (a) use of automated shading with proposed control algorithms can reduce the site energy in the range of 11.6-13.0%; in regard to source (primary) energy in the range of 20.1-21.6%, (b) the differences between algorithms in regard to energy savings are not high, (c) the differences between algorithms in regard to number of hours of retracted shades are visible, (e) the control algorithms have a strong influence on shade operation and oscillation of shade can occur, (d) additional energy consumption caused by motor, sensors and a small microprocessor in the analyzed case is very small.« less
Skylight energy performance and design optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arasteh, D.; Johnson, R.; Selkowitz, S.
1984-02-01
Proper skylight utilization can significantly lower energy requirements and peak electrical loads for space conditioning and lighting in commercial buildings. In this study we systematically explore the energy effects of skylight systems in a prototypical office building and examine the savings from daylighting. The DOE-2.1B energy analysis computer program with its newly incorporated daylighting algorithms was used to generate more than 2000 parametric simulations for seven US climates. The parameters varied include skylight-to-roof ratio, shading coefficient, visible transmittance, skylight well light loss, electric lighting power density, roof heat transfer coefficient, and type of electric lighting control. For specific climates wemore » identify roof/skylight characteristics that minimize total energy or peak electrical load requirements.« less
Shumack, Stephen; Murrell, Dedee F; Rubel, Diana M; Fernández‐Peñas, Pablo; Salmon, Robert; Hewitt, Daniel; Foley, Peter; Spelman, Lynda
2015-01-01
Abstract Australia has the highest prevalence of actinic keratoses (AK) worldwide. Because of the risk of transformation of AK to invasive squamous cell carcinomas, consensus guidelines recommend that AK are removed using appropriate therapies to prevent progression to invasive disease. Daylight photodynamic therapy (PDT) is emerging as an efficacious treatment for AK, particularly for patients who require treatment of large areas of chronic actinic damage that can be exposed easily to daylight. Daylight PDT with methyl aminolevulinate (MAL) cream is a simple treatment for AK, almost painless, well tolerated and convenient, requiring minimal time in the clinic. Randomised controlled studies from northern Europe and Australia support the use of daylight PDT as an effective therapy for grade I and II AK on the face and scalp. There is sufficient daylight to conduct daylight PDT in Australia at any time of the year and during most weather conditions. Hence, daylight PDT with MAL can be included as an effective and well‐tolerated new treatment option for the treatment of AK in Australia. These consensus recommendations provide guidelines for Australian clinicians on the use of daylight PDT in the treatment of diagnosed AK. PMID:26033230
Adaptive chromogenic materials and devices
NASA Astrophysics Data System (ADS)
Sixou, Pierre; Guillard, H.; Labonne, L.; Gandolfo, V.
2003-03-01
Electrically controllable glasses can be used to control daylight and solar energy in buildings and in automotives in order to improve quality of life and to save energy spent on lighting, cooling and heating. The paper discusses the case of switchable glazings using liquid crystal/polymer micro-composites. A comparison with other technologies (like inorganic electrochromics, thermotropic gels and dispersed particles) is drawn.
Building integrated semi-transparent photovoltaics: energy and daylighting performance
NASA Astrophysics Data System (ADS)
Kapsis, Konstantinos; Athienitis, Andreas K.
2011-08-01
This paper focuses on modeling and evaluation of semi-transparent photovoltaic technologies integrated into a coolingdominated office building façade by employing the concept of three-section façade. An energy simulation model is developed, using building simulation software, to investigate the effect of semi-transparent photovoltaic transmittance on the energy performance of an office in a typical office building in Montreal. The analysis is performed for five major façade orientations and two façade configurations. Using semi-transparent photovoltaic integrated into the office façade, electricity savings of up to 53.1% can be achieved compared to a typical office equipped with double glazing with Argon filling and a low emissivity coating, and lighting controlled based on occupancy and daylight levels.e.c
Energy-saving approaches to solid state street lighting
NASA Astrophysics Data System (ADS)
Vitta, Pranciškus; Stanikūnas, Rytis; Tuzikas, Arūnas; Reklaitis, Ignas; Stonkus, Andrius; Petrulis, Andrius; Vaitkevičius, Henrikas; Žukauskas, Artūras
2011-10-01
We consider the energy-saving potential of solid-state street lighting due to improved visual performance, weather sensitive luminance control and tracking of pedestrians and vehicles. A psychophysical experiment on the measurement of reaction time with a decision making task was performed under mesopic levels of illumination provided by a highpressure sodium (HPS) lamp and different solid-state light sources, such as daylight and warm-white phosphor converted light-emitting diodes (LEDs) and red-green-blue LED clusters. The results of the experiment imply that photopic luminances of road surface provided by solid-state light sources with an optimized spectral power distribution might be up to twice as low as those provided by the HPS lamp. Dynamical correction of road luminance against road surface conditions typical of Lithuanian climate was estimated to save about 20% of energy in comparison with constant-level illumination. The estimated energy savings due to the tracking of pedestrians and vehicles amount at least 25% with the cumulative effect of intelligent control of at least 40%. A solid-state street lighting system with intelligent control was demonstrated using a 300 m long test ground consisting of 10 solid-state street luminaires, a meteorological station and microwave motion sensor network operated via power line communication.
Neittaanmäki-Perttu, Noora; Grönroos, Mari; Karppinen, Toni; Snellman, Erna; Rissanen, Pekka
2016-02-01
Daylight-mediated photodynamic therapy (DL-PDT) is considered as effective as conventional PDT using artificial light (light-emitting diode (LED)-PDT) for treatment of actinic keratoses (AK). This randomized prospective non-sponsored study assessed the cost-effectiveness of DL-PDT compared with LED-PDT. Seventy patients with 210 AKs were randomized to DL-PDT or LED-PDT groups. Effectiveness was assessed at 6 months. The costs included societal costs and private costs, including the time patients spent in treatment. Results are presented as incremental cost-effectiveness ratio (ICER). The total costs per patient were significantly lower for DL-PDT (€132) compared with LED-PDT (€170), giving a cost saving of €38 (p = 0.022). The estimated probabilities for patients' complete response were 0.429 for DL-PDT and 0.686 for LED-PDT; a difference in probability of being healed of 0.257. ICER showed a monetary gain of €147 per unit of effectiveness lost. DL-PDT is less costly and less effective than LED-PDT. In terms of cost-effectiveness analysis, DL-PDT provides lower value for money compared with LED-PDT.
Super Blood Moon Lunar Eclipse
2017-12-08
What time will you be able to view the Super Moon Eclipse? The images below show times to view it for Eastern Daylight Time (EDT), Central Daylight Time (CDT), Mountain Daylight Time (MDT) and Pacific Daylight Time (PDT). All of South America and most of North and Central America will see the entire eclipse, while those west of roughly 120°W will see it in progress at moonrise. You won’t need special equipment to see it. Just go outside and look up! NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linhart, Friedrich; Scartezzini, Jean-Louis
2010-04-15
Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of lessmore » than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)« less
White Nail Radio Transmitter: Billion Dollar Savings through Energy Efficiency
2011-05-10
increase efficiency and reduce overall energy consumption ashore by 50 percent CNO, Navy Energy Vision, P 10 White Nail Vision Your Cell Phone Cell...Estimated Total Number of transmitters 3,000,000 Estimated total power saved Watt 1,250,000,000 Cell Phone Transmitter Efficiency 1.25 Gigawatts saved...Greenhouse Gas Power 4 1 Energy Navy Use 7.3 Billion kWh White Nail Cell Phone Savings 11 Billion kWh One and a half times!!! Saves the output of four of
Simulation of tree shade impacts on residential energy use for space conditioning in Sacramento
NASA Astrophysics Data System (ADS)
Simpson, J. R.; McPherson, E. G.
Tree shade reduces summer air conditioning demand and increases winter heating load by intercepting solar energy that would otherwise heat the shaded structure. We evaluate the magnitude of these effects here for 254 residential properties participating in a utility sponsored tree planting program in Sacramento, California. Tree and building characteristics and typical weather data are used to model hourly shading and energy used for space conditioning for each building for a period of one year. There were an average of 3.1 program trees per property which reduced annual and peak (8 h average from 1 to 9 p.m. Pacific Daylight Time) cooling energy use 153 kWh (7.1%) and 0.08 kW (2.3%) per tree, respectively. Annual heating load increased 0.85 GJ (0.80 MBtu, 1.9%) per tree. Changes in cooling load were smaller, but percentage changes larger, for newer buildings. Averaged over all homes, annual cooling savings of 15.25 per tree were reduced by a heating penalty of 5.25 per tree, for net savings of 10.00 per tree from shade. We estimate an annual cooling penalty of 2.80 per tree and heating savings of 6.80 per tree from reduced wind speed, for a net savings of 4.00 per tree, and total annual savings of 14.00 per tree (43.00 per property). Results are found to be consistent with previous simulations and the limited measurements available.
Highlighting High Performance: Michael E. Capuano Early Childhood Center; Somerville, Massachusetts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2006-03-01
This brochure describes the key high-performance building features of the Michael E. Capuano Early Childhood Center. The brochure was paid for by the Massachusetts Technology Collaborative as part of their Green Schools Initiative. High-performance features described are daylighting and energy-efficient lighting, indoor air quality, solar and wind energy, building envelope, heating and cooling systems, water conservation, and acoustics. Energy cost savings are also discussed.
Angular selective window systems: Assessment of technical potential for energy savings
Fernandes, Luis L.; Lee, Eleanor S.; McNeil, Andrew; ...
2014-10-16
Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAEmore » 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.« less
An Adaptive Intelligent Integrated Lighting Control Approach for High-Performance Office Buildings
NASA Astrophysics Data System (ADS)
Karizi, Nasim
An acute and crucial societal problem is the energy consumed in existing commercial buildings. There are 1.5 million commercial buildings in the U.S. with only about 3% being built each year. Hence, existing buildings need to be properly operated and maintained for several decades. Application of integrated centralized control systems in buildings could lead to more than 50% energy savings. This research work demonstrates an innovative adaptive integrated lighting control approach which could achieve significant energy savings and increase indoor comfort in high performance office buildings. In the first phase of the study, a predictive algorithm was developed and validated through experiments in an actual test room. The objective was to regulate daylight on a specified work plane by controlling the blind slat angles. Furthermore, a sensor-based integrated adaptive lighting controller was designed in Simulink which included an innovative sensor optimization approach based on genetic algorithm to minimize the number of sensors and efficiently place them in the office. The controller was designed based on simple integral controllers. The objective of developed control algorithm was to improve the illuminance situation in the office through controlling the daylight and electrical lighting. To evaluate the performance of the system, the controller was applied on experimental office model in Lee et al.'s research study in 1998. The result of the developed control approach indicate a significantly improvement in lighting situation and 1-23% and 50-78% monthly electrical energy savings in the office model, compared to two static strategies when the blinds were left open and closed during the whole year respectively.
NASA Technical Reports Server (NTRS)
Griffin, Brand Norman
2010-01-01
With 1 rover, 2 astronauts and 3 days, the Apollo 17 Mission covered over 30 km, setup 10 scientific experiments and returned 110 kg of samples. This is a lot of science in a short time and the inspiration for a barebones, return-to-the-Moon strategy called Daylight Exploration. The Daylight Exploration approach poses an answer to the question, What could the Apollo crew have done with more time and today s robotics? In contrast to more ambitious and expensive strategies that create outposts then rely on pressurized rovers to drive to the science sites, Daylight Exploration is a low-overhead approach conceived to land near the scientific site, conduct Apollo-like exploration then leave before the sun goes down. A key motivation behind Daylight Exploration is cost reduction, but it does not come at the expense of scientific exploration. As a goal, Daylight Exploration provides access to the top 10 science sites by using the best capabilities of human and robotic exploration. Most science sites are within an equatorial band of 26 degrees latitude and on the Moon, at the equator, the day is 14 Earth days long; even more important, the lunar night is 14 days long. Human missions are constrained to 12 days because the energy storage systems required to operate during the lunar night adds mass, complexity and cost. In addition, short missions are beneficial because they require fewer consumables, do not require an airlock, reduce radiation exposure, minimize the dwell-time for the ascent and orbiting propulsion systems and allow a low-mass, campout accommodations. Key to Daylight Exploration is the use of piloted rovers used as tele-operated science platforms. Rovers are launched before or with the crew, and continue to operate between crew visits analyzing and collecting samples during the lunar daylight
Prioritizing Sleep Health: Public Health Policy Recommendations.
Barnes, Christopher M; Drake, Christopher L
2015-11-01
The schedules that Americans live by are not consistent with healthy sleep patterns. In addition, poor access to educational and treatment aids for sleep leaves people engaging in behavior that is harmful to sleep and forgoing treatment for sleep disorders. This has created a sleep crisis that is a public health issue with broad implications for cognitive outcomes, mental health, physical health, work performance, and safety. New public policies should be formulated to address these issues. We draw from the scientific literature to recommend the following: establishing national standards for middle and high school start times that are later in the day, stronger regulation of work hours and schedules, eliminating daylight saving time, educating the public regarding the impact of electronic media on sleep, and improving access to ambulatory in-home diagnostic testing for sleep disorders. © The Author(s) 2015.
NASA Astrophysics Data System (ADS)
Rosin, Argo; Moller, Taavi; Lehtla, Madis; Hoimoja, Hardi
2010-01-01
This article analyses household electricity consumption based on an object in Estonia. Energy consumption of workday and holiday by loads (including high and low tariff energy consumption) is discussed. The final part describes the evaluation of profitability of common investments of consumption shifting and replacing inefficient devices with more efficient ones. Additionally it describes shifting problems and shifting equipment profitability in real-time tariff system.
NASA Astrophysics Data System (ADS)
Tang, Dunbing; Dai, Min
2015-09-01
The traditional production planning and scheduling problems consider performance indicators like time, cost and quality as optimization objectives in manufacturing processes. However, environmentally-friendly factors like energy consumption of production have not been completely taken into consideration. Against this background, this paper addresses an approach to modify a given schedule generated by a production planning and scheduling system in a job shop floor, where machine tools can work at different cutting speeds. It can adjust the cutting speeds of the operations while keeping the original assignment and processing sequence of operations of each job fixed in order to obtain energy savings. First, the proposed approach, based on a mixed integer programming mathematical model, changes the total idle time of the given schedule to minimize energy consumption in the job shop floor while accepting the optimal solution of the scheduling objective, makespan. Then, a genetic-simulated annealing algorithm is used to explore the optimal solution due to the fact that the problem is strongly NP-hard. Finally, the effectiveness of the approach is performed smalland large-size instances, respectively. The experimental results show that the approach can save 5%-10% of the average energy consumption while accepting the optimal solution of the makespan in small-size instances. In addition, the average maximum energy saving ratio can reach to 13%. And it can save approximately 1%-4% of the average energy consumption and approximately 2.4% of the average maximum energy while accepting the near-optimal solution of the makespan in large-size instances. The proposed research provides an interesting point to explore an energy-aware schedule optimization for a traditional production planning and scheduling problem.
Heliostat design for the daylighting system.
Chang, Chih-Hung; Hsiso, Horng-Ching; Chang, Cheng-Ming; Wang, Chen-You; Lin, Tzung-Han; Chen, Yi-Yung; Lai, Yi-Lung; Yen, Cho-Jung; Chen, Kuan-Yu; Whang, Allen Jong-Woei
2014-10-10
The daylighting system is designed to guide sunlight into buildings for illumination. It has the best illumination performance when sunlight vertically impinges on the collector of the daylighting system, while it has low performance when sunlight impinges obliquely. To overcome the problem, this paper investigates the design of a heliostat that reflects sunlight vertically onto a daylighting system. This study proposes a 3×3 mirror matrix heliostat, which is different from the traditional heliostat with one single mirror. With the heliostat, the system efficiency increases as high as 3.32 times.
Multiobjective generalized extremal optimization algorithm for simulation of daylight illuminants
NASA Astrophysics Data System (ADS)
Kumar, Srividya Ravindra; Kurian, Ciji Pearl; Gomes-Borges, Marcos Eduardo
2017-10-01
Daylight illuminants are widely used as references for color quality testing and optical vision testing applications. Presently used daylight simulators make use of fluorescent bulbs that are not tunable and occupy more space inside the quality testing chambers. By designing a spectrally tunable LED light source with an optimal number of LEDs, cost, space, and energy can be saved. This paper describes an application of the generalized extremal optimization (GEO) algorithm for selection of the appropriate quantity and quality of LEDs that compose the light source. The multiobjective approach of this algorithm tries to get the best spectral simulation with minimum fitness error toward the target spectrum, correlated color temperature (CCT) the same as the target spectrum, high color rendering index (CRI), and luminous flux as required for testing applications. GEO is a global search algorithm based on phenomena of natural evolution and is especially designed to be used in complex optimization problems. Several simulations have been conducted to validate the performance of the algorithm. The methodology applied to model the LEDs, together with the theoretical basis for CCT and CRI calculation, is presented in this paper. A comparative result analysis of M-GEO evolutionary algorithm with the Levenberg-Marquardt conventional deterministic algorithm is also presented.
Bats on a Budget: Torpor-Assisted Migration Saves Time and Energy
McGuire, Liam P.; Jonasson, Kristin A.; Guglielmo, Christopher G.
2014-01-01
Bats and birds must balance time and energy budgets during migration. Migrating bats face similar physiological challenges to birds, but nocturnality creates special challenges for bats, such as a conflict between travelling and refueling, which many birds avoid by feeding in daylight and flying at night. As endothermic animals, bats and birds alike must expend substantial amounts of energy to maintain high body temperatures. For migratory birds refueling at stopovers, remaining euthermic during inactive periods reduces the net refuelling rate, thereby prolonging stopover duration and delaying subsequent movement. We hypothesized that bats could mitigate similar ambient-temperature dependent costs by using a torpor-assisted migration strategy. We studied silver-haired bats Lasionycteris noctivagans during autumn migration using a combination of respirometry and temperature-sensitive radiotelemetry to estimate energy costs incurred under ambient temperature conditions, and the energy that bats saved by using torpor during daytime roosting periods. All bats, regardless of sex, age, or body condition used torpor at stopover and saved up to 91% of the energy they would have expended to remain euthermic. Furthermore, bats modulated use of torpor depending on ambient temperature. By adjusting the time spent torpid, bats achieved a rate of energy expenditure independent of the ambient temperature encountered at stopover. By lowering body temperature during inactive periods, fuel stores are spared, reducing the need for refuelling. Optimal migration models consider trade-offs between time and energy. Heterothermy provides a physiological strategy that allows bats to conserve energy without paying a time penalty as they migrate. Although uncommon, some avian lineages are known to use heterothermy, and current theoretical models of migration may not be appropriate for these groups. We propose that thermoregulatory strategies should be an important consideration of future migration studies of both bats and birds. PMID:25551615
Stalidzans, E; Zacepins, A; Kviesis, A; Brusbardis, V; Meitalovs, J; Paura, L; Bulipopa, N; Liepniece, M
2017-02-01
Honey bee wintering in a wintering building (indoors) with controlled microclimate is used in some cold regions to minimize colony losses due to the hard weather conditions. The behavior and possible state of bee colonies in a dark room, isolated from natural environment during winter season, was studied by indirect temperature measurements to analyze the expression of their annual rhythm when it is not affected by ambient temperature, rain, snow, wind, and daylight. Thus, the observed behavior in the wintering building is initiated solely by bee colony internal processes. Experiments were carried out to determine the dynamics of temperature above the upper hive body and weight dynamics of indoors and outdoors wintered honey bee colonies and their brood-rearing performance in spring. We found significantly lower honey consumption-related weight loss of indoor wintered colonies compared with outdoor colonies, while no significant difference in the amount of open or sealed brood was found, suggesting that wintering building saves food and physiological resources without an impact on colony activity in spring. Indoor wintered colonies, with or without thermal insulation, did not have significant differences in food consumption and brood rearing in spring. The thermal behavior and weight dynamics of all experimental groups has changed in the middle of February possibly due to increased brood-rearing activity. Temperature measurement above the upper hive body is a convenient remote monitoring method of wintering process. Predictability of food consumption in a wintering building, with constant temperature, enables wintering without oversupply of wintering honey. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Optimal Self-Tuning PID Controller Based on Low Power Consumption for a Server Fan Cooling System.
Lee, Chengming; Chen, Rongshun
2015-05-20
Recently, saving the cooling power in servers by controlling the fan speed has attracted considerable attention because of the increasing demand for high-density servers. This paper presents an optimal self-tuning proportional-integral-derivative (PID) controller, combining a PID neural network (PIDNN) with fan-power-based optimization in the transient-state temperature response in the time domain, for a server fan cooling system. Because the thermal model of the cooling system is nonlinear and complex, a server mockup system simulating a 1U rack server was constructed and a fan power model was created using a third-order nonlinear curve fit to determine the cooling power consumption by the fan speed control. PIDNN with a time domain criterion is used to tune all online and optimized PID gains. The proposed controller was validated through experiments of step response when the server operated from the low to high power state. The results show that up to 14% of a server's fan cooling power can be saved if the fan control permits a slight temperature response overshoot in the electronic components, which may provide a time-saving strategy for tuning the PID controller to control the server fan speed during low fan power consumption.
The energy performance of prototype holographic glazings
NASA Astrophysics Data System (ADS)
Papamichael, K.; Beltran, L.; Furler, R.; Lee, E. S.; Selkowitz, S.; Rubin, M.
1993-02-01
We report on the simulation of the energy performance of prototype holographic glazings in commercial office buildings in a California climate. These prototype glazings, installed above conventional side windows, are designed to diffract the transmitted solar radiation and reflect it off the ceiling, providing adequate daylight illumination for typical office tasks up to 10m from the window. In this study, we experimentally determined a comprehensive set of solar-optical properties and characterized the contribution of the prototype holographic glazings to workplane illuminance in a scale model of a typical office space. We then used the scale model measurements to simulate the energy performance of the holographic glazings over the course of an entire year for four window orientations (North, East, South and West) for the inland Los Angeles climate, using the DOE-2.lD building energy analysis computer program. The results of our experimental analyses indicate that these prototype holographic glazings diffract only a small fraction of the incident light. The results of this study indicate that these prototype holographic glazings will not save energy in commercial office buildings. Their performance is very similar to that of clear glass, which, through side windows, cannot efficiently illuminate more than a 4-6 m depth of a building's perimeter, because the cooling penalties due to solar heat gain are greater than the electric lighting savings due to daylighting.
In Search of a Good Night's Sleep.
Leahy, Laura G
2017-10-01
A good night's sleep is essential to overall physical, cognitive, and emotional well-being. Sleep deprivation, whether general or related to time changes (e.g., daylight saving time), contributes to decreased cognition, impaired memory, poor coordination, mood fluctuations, increased risk of heart disease and diabetes, and weight gain, among others. The sleep cycle is defined by five stages and two distinct parts-rapid eye movement (REM) and non-REM sleep-that work to promote not only the quantity of sleep but also the quality of sleep, which impacts overall health. Each stage of sleep is influenced by various neurochemical actions among the brain regions. The neurochemistry and neuropath-ways related to the sleep/wake cycle as well as the mechanisms of action of sleep-inducing and wake-promoting medications are explored. [Journal of Psychosocial Nursing and Mental Health Services, 55(10), 19-26.]. Copyright 2017, SLACK Incorporated.
Human daily rhythms measured for one year.
Binkley, S; Tome, M B; Crawford, D; Mosher, K
1990-08-01
Four human subjects recorded their wake-up and to-sleep times for one year each. The data were plotted to display individual circadian rhythms and the data were analyzed statistically. First, individuals had characteristic patterns in which visible changes in the patterns were observed mainly when time zones were changed because of travel. Second, the months with the latest wake-up and latest to-sleep times concentrated around the winter solstice; the months with the earliest wake-up and earliest to-sleep times concentrated around the fall equinox. Third, new moon versus full moon days were not different. Fourth, one-hour changes between standard and daylight savings time in the USA were reflected by near one-hour changes in two subjects, but not in a third. Fifth, weekend delays in wake-up time (0.8-1.6 hours), weekend delays in to-sleep time (0.1-0.5 hours), and shorter weekend awake time (0.8-1.3 hours) were observed. Sixth, throughout the year, wake-up times were close to the time of sunrise, but to-sleep times were several hours past sunset.
Tornado Strikes Southern Maryland
NASA Technical Reports Server (NTRS)
2002-01-01
Evening light catches the tops of towering thunderheads over the Mid-Atlantic states on April 28, 2002. The powerful storms spawned several tornados, one of which was classified as an F4 tornado. The powerful tornado touched down in the southern Maryland town of La Plata, destroying most of the historic downtown. The twister-one of the strongest ever to hit the state-beat a 24-mile swath running west to east through the state and claimed at least three lives. The image above was taken by the Geostationary Operational Environmental Satellite (GOES) at 7:15 PM Eastern Daylight Savings Time. A large version of the animation shows more detail. (5.9 MB Quicktime) Image courtesy National Oceanic and Atmospheric Administration (NOAA) and the GOES Project Science Office. Animation by Robert Simmon, NASA GSFC.
78 FR 64026 - Investigative Hearing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... Investigative Hearing. On Friday, May 17, 2013, at 6:01 p.m. eastern daylight time, eastbound Metro-North... $18.5 million. On Tuesday, May 28, 2013, at 11:57 a.m. eastern daylight time, Metro-North Railroad...; and Metro-North's organizational safety culture. Parties to the hearing include the Federal Railroad...
Traffic-aware energy saving scheme with modularization supporting in TWDM-PON
NASA Astrophysics Data System (ADS)
Xiong, Yu; Sun, Peng; Liu, Chuanbo; Guan, Jianjun
2017-01-01
Time and wavelength division multiplexed passive optical network (TWDM-PON) is considered to be a primary solution for next-generation passive optical network stage 2 (NG-PON2). Due to the feature of multi-wavelength transmission of TWDM-PON, some of the transmitters/receivers at the optical line terminal (OLT) could be shut down to reduce the energy consumption. Therefore, a novel scheme called traffic-aware energy saving scheme with modularization supporting is proposed. Through establishing the modular energy consumption model of OLT, the wavelength transmitters/receivers at OLT could be switched on or shut down adaptively depending on sensing the status of network traffic load, thus the energy consumption of OLT will be effectively reduced. Furthermore, exploring the technology of optical network unit (ONU) modularization, each module of ONU could be switched to sleep or active mode independently in order to reduce the energy consumption of ONU. Simultaneously, the polling sequence of ONU could be changed dynamically via sensing the packet arrival time. In order to guarantee the delay performance of network traffic, the sub-cycle division strategy is designed to transmit the real-time traffic preferentially. Finally, simulation results verify that the proposed scheme is able to reduce the energy consumption of the network while maintaining the traffic delay performance.
An Efficient Power Saving Mechanism for Delay-Guaranteed Services in IEEE 802.16e
NASA Astrophysics Data System (ADS)
Park, Yunju; Hwang, Gang Uk
As the IEEE 802.16e Wireless Metropolitan Access Network (WMAN) supports the mobility of a mobile station (MS), increasing MS power efficiency has become an important issue. In this paper, we analyze the sleep-mode operation for an efficient power saving mechanism for delay-guaranteed services in the IEEE 802.16e WMAN and observe the effects of the operating parameters related to this operation. For the analysis we use the M/GI/1/K queueing system with multiple vacations, exhaustive services and setup times. In the analysis, we consider the power consumption during the wake-mode period as well as the sleep-mode period. As a performance measure for the power consumption, we propose the power consumption per unit time per effective arrival which considers the power consumption and the packet blocking probability simultaneously. In addition, since we consider delay-guaranteed services, the average packet response delay is also considered as a performance measure. Based on the performance measures, we obtain the optimal sleep-mode operation which minimizes the power consumption per unit time per effective arrival with a given delay requirement. Numerical studies are also provided to investigate the system performance and to show how to achieve our objective.
Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics
NASA Astrophysics Data System (ADS)
Dvořák, Lukáš; Fojtášek, Kamil
2015-05-01
Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.
Energy-saving scheme based on downstream packet scheduling in ethernet passive optical networks
NASA Astrophysics Data System (ADS)
Zhang, Lincong; Liu, Yejun; Guo, Lei; Gong, Xiaoxue
2013-03-01
With increasing network sizes, the energy consumption of Passive Optical Networks (PONs) has grown significantly. Therefore, it is important to design effective energy-saving schemes in PONs. Generally, energy-saving schemes have focused on sleeping the low-loaded Optical Network Units (ONUs), which tends to bring large packet delays. Further, the traditional ONU sleep modes are not capable of sleeping the transmitter and receiver independently, though they are not required to transmit or receive packets. Clearly, this approach contributes to wasted energy. Thus, in this paper, we propose an Energy-Saving scheme that is based on downstream Packet Scheduling (ESPS) in Ethernet PON (EPON). First, we design both an algorithm and a rule for downstream packet scheduling at the inter- and intra-ONU levels, respectively, to reduce the downstream packet delay. After that, we propose a hybrid sleep mode that contains not only ONU deep sleep mode but also independent sleep modes for the transmitter and the receiver. This ensures that the energy consumed by the ONUs is minimal. To realize the hybrid sleep mode, a modified GATE control message is designed that involves 10 time points for sleep processes. In ESPS, the 10 time points are calculated according to the allocated bandwidths in both the upstream and the downstream. The simulation results show that ESPS outperforms traditional Upstream Centric Scheduling (UCS) scheme in terms of energy consumption and the average delay for both real-time and non-real-time packets downstream. The simulation results also show that the average energy consumption of each ONU in larger-sized networks is less than that in smaller-sized networks; hence, our ESPS is better suited for larger-sized networks.
NASA Astrophysics Data System (ADS)
Markou, M. T.; Kambezidis, H. D.; Bartzokas, A.; Darula, S.; Kittler, R.
2007-12-01
In this work, daylight reference years (DRYs), based on daylight and solar radiation measurements, are designed for two European cities, Athens, Greece and Bratislava, Slovakia, by using the Danish method, the Festa-Ratto technique and the Modified Sandia National Laboratories methodology. The data basis consists of 5-minute values of global and diffuse horizontal illuminance, global and diffuse horizontal irradiance, zenith luminance and solar altitude as well as of daily values of sunshine duration for 5 years for Athens and 8 years for Bratislava. Moreover, Linke's turbidity factor, luminous turbidity factor and relative sunshine duration are calculated and utilized. Then, for each DRY, the predominant sky-luminance distributions over Athens and Bratislava are identified, by using the methodology of Kittler et al., who corresponded the main sky conditions to 15 theoretical sky standards in diagrams of the ratio of zenith luminance to diffuse horizontal illuminance against solar altitude. For both cities the three aforementioned methods do not create identical DRYs. Despite the differences, the sky types defined for each of the two places seem not to depend on the choice of DRY. The predominant sky standard, for all of them, is a cloudless, polluted sky with a broad solar corona for Athens and an overcast sky with slight brightening towards the sun as well as very clear sky with low atmospheric turbidity for Bratislava. However, the selection of the DRY, which represents best the daylight conditions, is necessary for studies in saving energy in buildings. The DRY, which is created by the Modified Sandia National Laboratories method, is chosen for most cases, while the one created by the Danish method is also useful on certain occasions.
11 CFR 100.19 - File, filed or filing (2 U.S.C. 434(a)).
Code of Federal Regulations, 2014 CFR
2014-01-01
... Time on the filing date, except that pre-election reports must have a postmark dated no later than 11:59 p.m. Eastern Standard/Daylight Time on the fifteenth day before the date of the election. (2... Standard/Daylight Time on the filing date. (d) 48-hour and 24-hour reports of independent expenditures—(1...
Kirchberger, Inge; Wolf, Kathrin; Heier, Margit; Kuch, Bernhard; von Scheidt, Wolfgang; Peters, Annette; Meisinger, Christa
2015-08-14
Some studies suggest that transitions to and from daylight saving time (DST) have an influence on acute myocardial infarction (AMI) incidence. However, the available publications have a number of limitations e.g. regarding sample size, exclusion of fatal AMI cases, precise assessment of AMI onset, and consideration of possible confounders, and they were conducted in countries with different geographical location. The objective of this study was to examine the association of DST transitions with AMI incidence recorded in the population-based German MONICA/KORA Myocardial Infarction Registry. The study sample consisted of 25,499 coronary deaths and non-fatal AMI cases aged 25-74 years. We used Poisson regression with indicator variables for the 3 days or the week after the spring and the autumn transition and adjusted for potential confounders to model the association between DST transitions and AMI incidence. In addition, we built an excess model by calculating observed over expected events per day. Overall, no significant changes of AMI risk during the first 3 days or 1 week after the transition to and from DST were found. However, subgroup analyses on the spring transition revealed significantly increased risks for men in the first 3 days after transition (RR 1.155, 95 % CI 1.000-1.334) and for persons who took angiotensine converting enzyme (ACE) inhibitors prior to the AMI (3 days: RR 1.489, 95 % CI 1.151-1.927; 1 week: RR 1.297, 95 % CI 1.063-1.582). After the clock shift in autumn, patients with a prior infarction had an increased risk to have a re-infarction (3 days: RR 1.319, 95 % CI 1.029-1.691; 1 week: RR 1.270, 95 % CI 1.048-1.539). Specific subgroups such as men and persons with a history of AMI or prior treatment with ACE inhibitors, may have a higher risk for AMI during DST. Further studies which include data on chronotype and sleep duration are needed in order to confirm these results.
Evaluation of Water consumption and savings achieved in Datacenters through Air side Economization
NASA Astrophysics Data System (ADS)
Mishra, Ravi
Recent researches and a few facility owners have focused on eliminating the chiller plant altogether by implementing 'Evaporative Cooling', as an alternative or augmentation to compressor-based air conditioning since the energy consumption is dominated by the compressor work (around 41%) in the chiller plant. Because evaporative cooling systems consume water, when evaluating the energy savings potential of these systems, it is imperative to consider not just their impacts on electricity use, but also their impacts on water consumption as well since Joe Kava, Google's head of data center operations, was quoted as saying that water is the "big elephant in the room" for data center companies. The objective of this study was to calculate the savings achieved in water consumption when these evaporative cooling systems were completely or partially marginalized when the facility is strictly working in the Economizer mode also known as 'free cooling' considering other modes of cooling required only for a part of the time when outside temperature, humidity and pollutant level were unfavorable causing improper functioning and reliability issues. The analysis was done on ASHRAE climatic zones with the help of TMY-3 weather data.
Daylighting performance and thermal implications of skylights vs. south-facing roof monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenbaum, M.; Coldham, B.
1997-12-31
This paper reports the results of a comparison of skylights vs. south-facing roof monitors for daylighting the north wall zone of a 10,000 ft{sup 2} office building near Manchester, NH. A physical model was constructed and tested. Simultaneously, the building`s annual thermal performance was modeled with Energy-10 hourly simulation software, and its peak heating and cooling load performance was modeled with the Carrier Corp. Hourly Analysis Program (HAP). Apertures were built into the roof of the model, and several skylight and south-facing roof monitor configurations were tested in both clear and overcast conditions. A design goal was to have themore » building be daylit on overcast as well as clear days. This goal was based more on enhancement of the working environment than it was on electrical energy savings. Monitors with overhangs performed poorly in the overcast conditions--it was determined that 2.4 times as much monitor aperture was needed to yield equivalent light levels in overcast conditions. The thermal models showed that the annual heating and cooling energy cost for the building was the same for either strategy, but that peak cooling loads and peak heating loads were lower with the skylit version. The authors concluded that skylights were preferred over monitors in this application, due to similar annual energy costs, lower peak loads, and lower construction cost.« less
Progress Towards Highly Efficient Windows for Zero—Energy Buildings
NASA Astrophysics Data System (ADS)
Selkowitz, Stephen
2008-09-01
Energy efficient windows could save 4 quads/year, with an additional 1 quad/year gain from daylighting in commercial buildings. This corresponds to 13% of energy used by US buildings and 5% of all energy used by the US. The technical potential is thus very large and the economic potential is slowly becoming a reality. This paper describes the progress in energy efficient windows that employ low-emissivity glazing, electrochromic switchable coatings and other novel materials. Dynamic systems are being developed that use sensors and controls to modulate daylighting and shading contributions in response to occupancy, comfort and energy needs. Improving the energy performance of windows involves physics in a variety of application: optics, heat transfer, materials science and applied engineering. Technical solutions must also be compatible with national policy, codes and standards, economics, business practice and investment, real and perceived risks, comfort, health, safety, productivity, amenities, and occupant preference and values. The challenge is to optimize energy performance by understanding and reinforcing the synergetic coupling between these many issues.
Rychlik, Reinhard; Kreimendahl, Fabian; Blaich, Cornelia; Calache, Hanny; Garcia-Godoy, Franklin; Kay, Elizabeth; Si, Yan; Zilberman, David; Zimmer, Stefan
2017-04-01
To analyze the influence of increasing the average consumption of sugar-free gum (SFG) in 25 industrialized countries on dental expenditures due to caries by the national health care systems. It was assumed that large cost savings were possible, because the regular consumption of SFG significantly reduces the relative risk of caries and therefore, improves dental health, which reduces expenditures on dental treatments. A budget impact analysis (BIA) was performed to model the decrease in the relative risk of caries and the subsequent cost savings for dental care. Annual consumption of SFG, dental expenditures due to caries, chewing frequencies by age groups and the relative risk reduction for caries due to the consumption of SFG were identified and used as model parameters. Three different scenarios for the increase in the number of SFG were calculated. Besides overall results for all countries together, analyses were conducted for countries grouped by regions and the Human Development Index (HDI). For the entity of all 25 analyzed countries together, possible annual cost savings range from US$805.77 M in the scenario with the lowest increase of SFG consumption up to US$18,248 billion in the scenario with the biggest increase of SFG consumption. Europe and the USA show potential cost savings of US$1,061 billion and US$2,071 billion per year, respectively, if all chewers increase their consumption of SFG by 1 piece per day. The analysis showed the potential cost savings in dental expenditures due to caries that can be achieved by only slightly increasing the consumption of SFG. The regular consumption of SFG cannot replace good dental hygiene like tooth brushing, but can have a significant impact on dental health, which can lead to increased cost savings for health care systems worldwide. Based on the fact that a regular consumption of sugar-free chewing gum has the beneficial effect of reducing caries prevalence, an increased consumption may not only lead to improved dental health but significant cost savings in expenditures for dental treatment worldwide.
Kriszbacher, Ildikó; Bódis, József; Boncz, Imre; Koppan, Agnes; Koppan, Miklós
2010-04-01
We investigated whether the time of sunrise and the number of daylight hours have an effect on the seasonality, or the daily rhythm of heart attack mortality. We analyzed retrospectively data of patients admitted to hospitals with the diagnosis of heart attack (n=32,329) and patients who deceased of a heart attack (n=5142) between January 1, 2004 and December 31, 2005 in Hungary. Heart attack mortality was highest during winter, while lowest number of events was recorded during summer . The daily peak of diurnality was between 6:00 am and 12:00 pm (33.77%). A positive correlation was found between the time of sunrise, time of sunset and the mortality caused by myocardial infarction (p<0,01). In the analysis of the number of daylight hours and the heart attack mortality we found a negative correlation (r=-0.105, p<0.05). No significant difference was found between sexes and different age-groups in heart attack mortality. Our data suggest, that the occurrence and the mortality of heart attack may be related to the time of sunrise and the number of daylight hours. Copyright 2008 Elsevier Ireland Ltd. All rights reserved.
Energy Saving in DC Electric Railways by Battery Substation
NASA Astrophysics Data System (ADS)
Sugimoto, Takeshi
New rolling vehicles used in dc electric railways are of the regenerative type. At less busy time a part of regenerative power is not used for powering vehicles, and canceled by changed air brake. Recently, significant attention has been paid to the development of secondary batteries for hybrid and electric motorcars. The use of this battery enables reduction in electric power consumption. Because we can charge excess regenerative power and use for powering vehicles after. Before the fact we compared the actual and simulated effective coefficient of regenerative energy, we confirmed the suitability of the simulation model. In this simulation, we studied the energy-saving effect of the battery substations and determined the battery capacity at which maximum power saving is achieved. We found that the power consumption could be reduced remarkably by using a 15-20kWh battery substation.
Bogers, Jan P.A.M.; Bostoen, Tijmen; Broekman, Theo G.
2016-01-01
Low vitamin D levels are associated with schizophrenia, but the possible association between vitamin D levels and illness severity or duration of exposure to daylight has barely been investigated. To compare vitamin D levels in therapy-refractory severely ill schizophrenia patients and members of staff. To investigate the influence of daylight exposure on vitamin D levels in patients. Vitamin D was measured in patients with therapy-resistant schizophrenia in April, after the winter, and in patients and staff members in June, after an exceptionally sunny spring. Vitamin D levels in April and June were compared in patients, and levels in June were compared in patients and staff. The influence of daylight was taken into account by comparing the time patients spent outdoors during the day with the recommended minimum time for adequate vitamin D synthesis, and by comparing time spent outdoors in patients and staff. Patients had high rates of vitamin D deficiency (79-90%) and lower levels of vitamin D than staff members (p < 0.001), independent of skin pigmentation. In patients, vitamin D levels did not normalize, despite the considerably longer than recommended exposure of the skin to daylight (p < 0.001) and the longer exposure in patients than in staff members (p = 0.003). The vitamin D deficiency of therapy-resistant schizophrenia patients is pronounced and cannot be explained by differences in skin pigmentation or by an inactive, indoor lifestyle on the ward. Even theoretically sufficient exposure of the patients to daylight did not ameliorate the low vitamin D levels. While vitamin D deficiency probably plays a role in somatic health problems, it may also play a role in schizophrenia. Interestingly, exposure to daylight during an unusually sunny spring was not sufficient to correct the vitamin D deficiency seen in the patients. This emphasizes the need to measure and correct vitamin D levels in these patients.
Anticipation and Choice Heuristics in the Dynamic Consumption of Pain Relief
Story, Giles W.; Vlaev, Ivo; Dayan, Peter; Seymour, Ben; Darzi, Ara; Dolan, Raymond J.
2015-01-01
Humans frequently need to allocate resources across multiple time-steps. Economic theory proposes that subjects do so according to a stable set of intertemporal preferences, but the computational demands of such decisions encourage the use of formally less competent heuristics. Few empirical studies have examined dynamic resource allocation decisions systematically. Here we conducted an experiment involving the dynamic consumption over approximately 15 minutes of a limited budget of relief from moderately painful stimuli. We had previously elicited the participants’ time preferences for the same painful stimuli in one-off choices, allowing us to assess self-consistency. Participants exhibited three characteristic behaviors: saving relief until the end, spreading relief across time, and early spending, of which the last was markedly less prominent. The likelihood that behavior was heuristic rather than normative is suggested by the weak correspondence between one-off and dynamic choices. We show that the consumption choices are consistent with a combination of simple heuristics involving early-spending, spreading or saving of relief until the end, with subjects predominantly exhibiting the last two. PMID:25793302
Anticipation and choice heuristics in the dynamic consumption of pain relief.
Story, Giles W; Vlaev, Ivo; Dayan, Peter; Seymour, Ben; Darzi, Ara; Dolan, Raymond J
2015-03-01
Humans frequently need to allocate resources across multiple time-steps. Economic theory proposes that subjects do so according to a stable set of intertemporal preferences, but the computational demands of such decisions encourage the use of formally less competent heuristics. Few empirical studies have examined dynamic resource allocation decisions systematically. Here we conducted an experiment involving the dynamic consumption over approximately 15 minutes of a limited budget of relief from moderately painful stimuli. We had previously elicited the participants' time preferences for the same painful stimuli in one-off choices, allowing us to assess self-consistency. Participants exhibited three characteristic behaviors: saving relief until the end, spreading relief across time, and early spending, of which the last was markedly less prominent. The likelihood that behavior was heuristic rather than normative is suggested by the weak correspondence between one-off and dynamic choices. We show that the consumption choices are consistent with a combination of simple heuristics involving early-spending, spreading or saving of relief until the end, with subjects predominantly exhibiting the last two.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, W.A.
Energy engineering and management combines engineering problem-solving and financial management techniques to reduce utility costs. At present, substantial amounts of time and money are being spent in order to attempt to quantify energy consumption and costs and define opportunities for savings. Unfortunately, accurate verification of results is often overlooked. Advances in technology during the last few years have made the installation of a permanent, PC-based monitoring system possible for any facility, often for no more than the cost of a detailed study. By investing initially in a monitoring system rather than audits or studies, the actual consumption and cost datamore » will be available on a continuing basis and can be used to produce immediate operational savings, more accurately analyze opportunities requiring capital investments, and to verify actual savings resulting from changes. A permanent monitoring system, installed as the first step in a utility cost reduction effort, to identify where and how energy is used in a facility on a dynamic and real-time basis, can provide the most valuable and cost-effective tool available to an energy manager. The resulting data allows energy consumption patterns and utility costs to be understood and managed in the same manner as all other costs within a facility.« less
Wastewater treatment process impact on energy savings and greenhouse gas emissions.
Mamais, D; Noutsopoulos, C; Dimopoulou, A; Stasinakis, A; Lekkas, T D
2015-01-01
The objective of this research was to assess the energy consumption of wastewater treatment plants (WWTPs), to apply a mathematical model to evaluate their carbon footprint, and to propose energy saving strategies that can be implemented to reduce both energy consumption and greenhouse gas (GHG) emissions in Greece. The survey was focused on 10 WWTPs in Greece with a treatment capacity ranging from 10,000 to 4,000,000 population equivalents (PE). Based on the results, annual specific energy consumption ranged from 15 to 86 kWh/PE. The highest energy consumer in all the WWTPs was aeration, accounting for 40-75% of total energy requirements. The annual GHG emissions varied significantly according to the treatment schemes employed and ranged between 61 and 161 kgCO₂e/PE. The highest values of CO₂emissions were obtained in extended aeration systems and the lowest in conventional activated sludge systems. Key strategies that the wastewater industry could adopt to mitigate GHG emissions are identified and discussed. A case study is presented to demonstrate potential strategies for energy savings and GHG emission reduction. Given the results, it is postulated that the reduction of dissolved oxygen (DO) set points and sludge retention time can provide significant energy savings and decrease GHG emissions.
Amount of water needed to save 1 m3 of water: life cycle assessment of a flow regulator
NASA Astrophysics Data System (ADS)
Berger, Markus; Söchtig, Michael; Weis, Christoph; Finkbeiner, Matthias
2017-06-01
Water saving devices in the sanitary equipment, such as flow regulators, are assumed to be environmentally advantageous even though their environmental benefit has never been compared to the environmental burden caused during their production und disposal. Therefore, a life cycle assessment according to ISO 14044 has been conducted to identify and quantify the environmental effects throughout the lifespan of a flow regulator. The analysis comprises the production of materials, manufacturing of components at suppliers, the assembly at NEOPERL®, all transports, savings of water and thermal energy during use as well as waste incineration including energy recovery in the end-of-life stage. Results show that the production of one flow regulator causes 0.12 MJ primary energy demand, a global warming potential of 5.9 g CO2-equivalent, and a water consumption of 30.3 ml. On the other hand, during a use of 10 years, it saves 19,231 MJ primary energy, 1223 kg CO2-equivalent, and avoids a water consumption of 790 l (166,200 l water use). Since local impacts of water consumption are more relevant than volumes, consequences of water consumption have been analyzed using recently developed impact assessment models. Accordingly, the production of a flow regulator causes 8.5 ml freshwater depletion, 1.4 × 10-13 disability adjusted life years, and 4.8 × 10-6 potentially disappeared fractions of species m2 a. Even though avoided environmental impacts resulting from water savings highly depend on the region where the flow regulator is used, the analysis has shown that environmental benefits are at least 15,000 times higher than impacts caused during the production.
Røislien, Jo; Søvik, Signe; Eken, Torsten
2018-01-01
Trauma is a leading global cause of death, and predicting the burden of trauma admissions is vital for good planning of trauma care. Seasonality in trauma admissions has been found in several studies. Seasonal fluctuations in daylight hours, temperature and weather affect social and cultural practices but also individual neuroendocrine rhythms that may ultimately modify behaviour and potentially predispose to trauma. The aim of the present study was to explore to what extent the observed seasonality in daily trauma admissions could be explained by changes in daylight and weather variables throughout the year. Retrospective registry study on trauma admissions in the 10-year period 2001-2010 at Oslo University Hospital, Ullevål, Norway, where the amount of daylight varies from less than 6 hours to almost 19 hours per day throughout the year. Daily number of admissions was analysed by fitting non-linear Poisson time series regression models, simultaneously adjusting for several layers of temporal patterns, including a non-linear long-term trend and both seasonal and weekly cyclic effects. Five daylight and weather variables were explored, including hours of daylight and amount of precipitation. Models were compared using Akaike's Information Criterion (AIC). A regression model including daylight and weather variables significantly outperformed a traditional seasonality model in terms of AIC. A cyclic week effect was significant in all models. Daylight and weather variables are better predictors of seasonality in daily trauma admissions than mere information on day-of-year.
Laibson, David; Mollerstrom, Johanna
2012-01-01
Bernanke (2005) hypothesized that a “global savings glut” was causing large trade imbalances. However, we show that the global savings rates did not show a robust upward trend during the relevant period. Moreover, if there had been a global savings glut there should have been a large investment boom in the countries that imported capital. Instead, those countries experienced consumption booms. National asset bubbles explain the international imbalances. The bubbles raised consumption, resulting in large trade deficits. In a sample of 18 OECD countries plus China, movements in home prices alone explain half of the variation in trade deficits. PMID:23750045
Freshwater savings from marine protein consumption
NASA Astrophysics Data System (ADS)
Gephart, Jessica A.; Pace, Michael L.; D'Odorico, Paolo
2014-01-01
Marine fisheries provide an essential source of protein for many people around the world. Unlike alternative terrestrial sources of protein, marine fish production requires little to no freshwater inputs. Consuming marine fish protein instead of terrestrial protein therefore represents freshwater savings (equivalent to an avoided water cost) and contributes to a low water footprint diet. These water savings are realized by the producers of alternative protein sources, rather than the consumers of marine protein. This study quantifies freshwater savings from marine fish consumption around the world by estimating the water footprint of replacing marine fish with terrestrial protein based on current consumption patterns. An estimated 7 600 km3 yr-1 of water is used for human food production. Replacing marine protein with terrestrial protein would require an additional 350 km3 yr-1 of water, meaning that marine protein provides current water savings of 4.6%. The importance of these freshwater savings is highly uneven around the globe, with savings ranging from as little as 0 to as much as 50%. The largest savings as a per cent of current water footprints occur in Asia, Oceania, and several coastal African nations. The greatest national water savings from marine fish protein occur in Southeast Asia and the United States. As the human population increases, future water savings from marine fish consumption will be increasingly important to food and water security and depend on sustainable harvest of capture fisheries and low water footprint growth of marine aquaculture.
Yang, Hang; Zhang, Yongxin; Zheng, Chenghang; Wu, Xuecheng; Chen, Linghong; Gao, Xiang; Fu, Joshua S
2018-05-10
The pollutant abatement systems are widely applied in the coal-fired power sector and the energy consumption was considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000 MW coal-fired power unit which meet the ultra-low emission limits and the factors of operating parameters including unit load and inlet concentration of pollutants on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The WFGD system consumed 67% of the rate while the SCR and ESP systems consumed 8.9% and 24.1%. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of WFGD system. Implication Statement The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabine Brueske, Caroline Kramer, Aaron Fisher
2015-06-01
Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. pulp and paper manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas, representing 52% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity
Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Petroleum Refining
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabine Brueske, Caroline Kramer, Aaron Fisher
2015-06-01
Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. petroleum refining. The study relies on multiple sources to estimate the energy used in nine individual process areas, representing 68% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This publication is one in an ongoing series of case studies for "Laboratories for the 21st Century," a joint program of the U.S. Environmental Protection Agency and the U.S. Department of Energy Federal Energy Management Program. It is intended for all those who plan, design, and construct public and private-sector laboratory buildings. This study describes how the Nidus Center, a nonprofit incubator for life sciences and plan biotechnology established by Monsanto Company, employs daylighting, an energy-efficient mechanical system featuring energy recovery, and water conservation practices, among others, to save energy and money and help conserve natural resources.
Pan Am gets big savings at no cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanz, D.
Pan American World Airways' contract with an energy management control systems distributor enabled the company's terminal and maintenance facilities at JFK airport in New York to shift from housekeeping to major savings without additional cost. Energy savings from a pneumatic control system were split almost equally between Pan Am and Thomas S. Brown Associates (TSBA) Inc., and further savings are expected from a planned computer-controlled system. A full-time energy manager, able to give top priority to energy-consumption problems, was considered crucial to the program's success. Early efforts in light-level reduction and equipment scheduling required extensive persuasion and policing, but successfulmore » energy savings allowed the manager to progress to the more-extensive plants with TSBA.« less
NASA Technical Reports Server (NTRS)
Soloway, Donald I.; Alberts, Thomas E.
1989-01-01
It is often proposed that the redundancy in choosing a force distribution for multiple arms grasping a single object should be handled by minimizing a quadratic performance index. The performance index may be formulated in terms of joint torques or in terms of the Cartesian space force/torque applied to the body by the grippers. The former seeks to minimize power consumption while the latter minimizes body stresses. Because the cost functions are related to each other by a joint angle dependent transformation on the weight matrix, it might be argued that either method tends to reduce power consumption, but clearly the joint space minimization is optimal. A comparison of these two options is presented with consideration given to computational cost and power consumption. Simulation results using a two arm robot system are presented to show the savings realized by employing the joint space optimization. These savings are offset by additional complexity, computation time and in some cases processor power consumption.
Energy-efficient building design in cold climates: Schools as a case study
NASA Astrophysics Data System (ADS)
Rangel Ruiz, Rocio
Buildings account for great amounts of greenhouse gas emissions. In terms of energy, buildings account for one third of the total amount of energy used in the country every year! Schools account for 14 percent of the energy used annually in commercial and institutional buildings. Further, schools are one of the most commonly constructed building types in Canada and spaces such as classrooms are often duplicated. This makes them preferred candidates for the research that was undertaken where energy-efficient solutions that can be transferred to different school designs were derived. Throughout the study, the Commercial Building Incentive Program (CBIP) was used as a benchmark. The objectives of the study were to demonstrate energy-efficient concepts, provide a case study to evaluate solutions, develop typological models and provide an understanding of the innovation process. The technological and societal aspects of the energy-efficient design were addressed. With respect to the technological aspects, the first step was the analysis of conventional design using a school in Calgary as a case study. The optimization of conventional design was undertaken using computer modeling to identify best practice solutions. Aspects that were included in the studies were lighting design, envelope characteristics, HVAC systems and building plant systems. The inclusion of passive design included the analysis of daylighting and natural ventilation. Computer modeling was used to assess daylighting in classrooms with unilateral and bilateral daylighting. Illuminance levels, glare and light distribution were evaluated. The study of natural ventilation was undertaken using literature review. Airflow and outdoor temperatures were the focus to identify solutions that could be incorporated into the design of classrooms. It was concluded that achieving excellence in energy efficiency in schools could be achieved using readily available technologies. Energy savings of up to 63 percent better than Canada's Model National Energy Code for Buildings (MNECB) reference case and utility cost savings of 30,000 (on a 50,000 annual cost) were achieved through conventional design optimization. Additional energy savings of three percent and utility cost savings of $7,000 were seen when passive strategies were included in the design. With respect to the societal aspects, an exploratory research study was undertaken to examine innovation. Architects and energy consultants were interviewed. All design professionals included in the study had participated in projects approved for a grant under CBIP. The purpose of the study was to identify drivers and barriers to energy efficiency. The study demonstrated that external and internal innovation pressures have a significant effect on whether or not the technology is adopted. Suggestions for reducing barriers and further promoting energy efficiency are discussed in this thesis. It is expected that the research will not only aid designers in assessing projects with regard to local priorities, but will also provide building guidelines that serve as tools for the development of the Canadian energy compliance for CO2 emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Wangda; McNeil, Andrew; Wetter, Michael
2013-05-23
Building designers are increasingly relying on complex fenestration systems to reduce energy consumed for lighting and HVAC in low energy buildings. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex fenestration systems. Depending on the configurations, the simulation can take hours or even days using a personal computer. This paper describes how to accelerate the matrix multiplication portion of a Radiance three-phase daylight simulation by conducting parallel computing on heterogeneous hardware of a personal computer. The algorithm was optimized and the computational part was implemented in parallel using OpenCL. The speed of new approach wasmore » evaluated using various daylighting simulation cases on a multicore central processing unit and a graphics processing unit. Based on the measurements and analysis of the time usage for the Radiance daylighting simulation, further speedups can be achieved by using fast I/O devices and storing the data in a binary format.« less
Potential reduction of energy consumption in public university library
NASA Astrophysics Data System (ADS)
Noranai, Z.; Azman, ADF
2017-09-01
Efficient electrical energy usage has been recognized as one of the important factor to reduce cost of electrical energy consumption. Various parties have been emphasized about the importance of using electrical energy efficiently. Inefficient usage of electrical energy usage lead to biggest factor increasing of administration cost in Universiti Tun Hussein Onn Malaysia. With this in view, a project the investigate potential reduction electrical energy consumption in Universiti Tun Hussein Onn Malaysia was carried out. In this project, a case study involving electrical energy consumption of Perpustakaan Tunku Tun Aminah was conducted. The scopes of this project are to identify energy consumption in selected building and to find the factors that contributing to wastage of electrical energy. The MS1525:2001, Malaysian Standard - Code of practice on energy efficiency and use of renewable energy for non-residential buildings was used as reference. From the result, 4 saving measure had been proposed which is change type of the lamp, install sensor, decrease the number of lamp and improve shading coefficient on glass. This saving measure is suggested to improve the efficiency of electrical energy consumption. Improve of human behaviour toward saving energy measure can reduce 10% from the total of saving cost while on building technical measure can reduce 90% from total saving cost.
Lara-Santillán, Pedro M; Mendoza-Villena, Montserrat; Fernández-Jiménez, L Alfredo; Mañana-Canteli, Mario
2014-01-01
This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008-2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002-2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.
Wastewater recycling and heat reclamation project: Red Lion Central Laundry, Portland, Oregon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garlick, T.F.; Halverson, M.A.; Ledbetter, M.R.
1997-06-01
This report discusses water, energy, and cost savings that can be achieved in a commercial laundry through the use of a wastewater recycling and heat recovery system. Cost savings are achieved through reductions in water use, reduction in sewage charges (typically based on water use), reductions in water heating energy, and potential reductions in water treatment chemicals because the recycled water has already been treated with soaps and conditioners. A recovery system saves water by recycling wash water that would normally be dumped into the city sewage system. Recycling the wash water produces considerable energy savings because the recycled watermore » has a higher temperature than fresh water. As a result, a hot water heater consumes less energy to heat the recycled water. The demonstration project discussed in this report was based in a large commercial laundry in Portland, Oregon. The laundry serves a large hotel/motel chain and processes an average of 25,000 pounds of laundry per day. A wastewater recovery system using a membrane microfiltration unit (MFU) was installed in the laundry in September 1995. Time series data of the water and energy consumption of the laundry were taken before and after installation of the MFU. Energy savings were measured by performing a thermal energy balance around the washing machines. Water savings were calculated by metering volumetric flow rates. After a period of approximately five months, the MFU has achieved final results of 52 percent savings in water consumption and 44 percent savings in energy to heat water. This five-month period represents a learning curve during which several small technical improvements were made to the MFU and laundry staff adjusted laundry operations to maximize the benefits of the MFU. An economic analysis discusses the impact of capital investment, daily consumption, and local utility rates on the payback period.« less
Rager, B; Lang, F R; Wagner, G G
2012-12-01
There is some research on personal reasons for saving money in the economic sciences. However, not much is known about the age differences of saving motives. In this vein, the future time perspective (FTP) is known to play a critical role for motivation across the life span. In this study, we introduce a new Saving Motive Inventory (SMI), which also covers saving goals after retirement. Furthermore, it is argued that additional saving motives that are not based on economic models of life-cycle saving also exist. In accordance with the socio-emotional selectivity theory, we explored age differences in an online survey with 496 participants from young (19-44 years), middle-aged (45-64 years), and older (65-86 years) adulthood, who completed a questionnaire on saving motives, personality, and future-related thinking (e.g., Future Time Perspective Scale, Life Orientation Test). Results of the explorative Factor Analysis (EFA) are consistent with the theoretical expectations. The factors are generativity, educational investment, consumption, indifference, and provision for death and dying. Together these five factors account for 67% of the variance. In general, the inventory is reliable and valid with respect to the expected internal and external criteria. It contributes to better understanding of saving motives over the lifespan, especially with respect to effects of the future time perspective.
Wrist activity in a woman: daily, weekly, menstrual, lunar, annual cycles?
Binkley, S
1992-09-01
Wrist activity was monitored continuously for one year in a woman who went about her normal life. The year of data were analyzed for changes and rhythms--daily, weekly, menstrual, lunar, annual. For each day, average motions/5 minutes, activity onset, activity offset, alpha (duration of activity), and acrophase were measured. Periodograms and average daily wave forms were calculated. Well-defined, entrained, daily rest-activity cycles were observed throughout the year with periods close to 24 hours. There was weekend delay (0.7 hours) in onset, weekend decrease in alpha (1.0 hours), and weekend advance of acrophase (0.4 hours). Motions/5 minutes decreased 9%, onsets were 0.3 hours later, and alphas were 0.4 hours shorter on menstrual cycle days 8 through 18 which should have encompassed the time of ovulation. Lunar phase had no effect. Annual changes in onset (1.1 hours), offset (1.2 hours), and acrophase (1.1 hours) were attributed to the 1-hour change between standard and daylight savings time.
Wind power as an electrical energy source in Illinois
NASA Astrophysics Data System (ADS)
Wendland, W. M.
1982-03-01
A preliminary estimate of the total wind power available in Illinois was made using available historical data, and projections of cost savings due to the presence of wind-generated electricity were attempted. Wind data at 10 m height were considered from nine different sites in the state, with three years data nominally being included. Wind-speed frequency histograms were developed for day and night periods, using a power law function to extrapolate the 10 m readings to 20 m. Wind speeds over the whole state were found to average over 8 mph, the cut-in point for most wind turbines, for from 40-63% of the time. A maximum of 75% run-time was determined for daylight hours in April-May. A reference 1.8 kW windpowered generator was used in annual demand projections for a reference one family home, using the frequency histograms. The small generator was projected to fulfill from 25-53% of the annual load, and, based on various cost assumptions, exhibited paybacks taking from 14-27 yr.
The Pasinetti-Solow Growth Model with Optimal Saving Behaviour: A Local Bifurcation Analysis
NASA Astrophysics Data System (ADS)
Commendatore, P.; Palmisani, C.
We present a discrete time version of the Pasinetti-Solow economic growth model. Workers and capitalists are assumed to save on the basis of rational choices. Workers face a finite time horizon and base their consumption choices on a life-cycle motive, whereas capitalists behave like an infinitely-lived dynasty. The accumulation of both capitalists' and workers' wealth through time is reduced to a two-dimensional map whose local asymptotic stability properties are studied. Various types of bifurcation emerge (flip, Neimark-Sacker, saddle-node and transcritical): a precondition for chaotic dynamics.
Field Commissioning of a Daylight-Dimming Lighting System.
ERIC Educational Resources Information Center
Floyd, David B.; Parker, Danny S.
A Florida elementary school cafeteria, retrofitted with a fluorescent lighting system that dims in response to available daylight, was evaluated through real time measurement of lighting and air conditioning power, work plane illumination, and interior/exterior site conditions. The new system produced a 27 percent reduction in lighting power due…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabine Brueske, Caroline Kramer, Aaron Fisher
Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. chemical manufacturing. The study relies on multiple sources to estimate the energy used in the production of 74 individual chemicals, representing 57% of sector-wide energy consumption. Energy savings opportunities for individual chemicals and for 15 subsectors of chemicals manufacturing are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.
Womack, James P; Jones, Daniel T
2005-03-01
During the past 20 years, the real price of most consumer goods has fallen worldwide, the variety of goods and the range of sales channels offering them have continued to grow, and product quality has steadily improved. So why is consumption often so frustrating? It doesn't have to be--and shouldn't be--the authors say. They argue that it's time to apply lean thinking to the processes of consumption--to give consumers the full value they want from goods and services with the greatest efficiency and the least pain. Companies may think they save time and money by off-loading work to the consumer but, in fact, the opposite is true. By streamlining their systems for providing goods and services, and by making it easier for customers to buy and use those products and services, a growing number of companies are actually lowering costs while saving everyone time. In the process, these businesses are learning more about their customers, strengthening consumer loyalty, and attracting new customers who are defecting from less user-friendly competitors. The challenge lies with the retailers, service providers, manufacturers, and suppliers that are not used to looking at total cost from the standpoint of the consumer and even less accustomed to working with customers to optimize the consumption process. Lean consumption requires a fundamental shift in the way companies think about the relationship between provision and consumption, and the role their customers play in these processes. It also requires consumers to change the nature of their relationships with the companies they patronize. Lean production has clearly triumphed over similar obstacles in recent years to become the dominant global manufacturing model. Lean consumption, its logical companion, can't be far behind.
Web survey of sleep problems associated with early-onset bipolar spectrum disorders.
Lofthouse, Nicholas; Fristad, Mary; Splaingard, Mark; Kelleher, Kelly; Hayes, John; Resko, Susan
2008-05-01
As research on sleep difficulties associated with Early-Onset Bipolar Spectrum Disorders (EBSD) is limited, a web-based survey was developed to further explore these problems. 494 parents of 4-to-12 year-olds, identified by parents as being diagnosed with EBSD, completed a web survey about past and current EBSD-related sleep problems. The survey included Children's Sleep Habits Questionnaire (CSHQ) items and sleep problems from the International Classification of Sleep Disorders 2nd edition. Nearly all parents reported some type of past or current EBSD-sleep problem. Most occurred during a worst mood period, particularly with mixed manic-depressive symptoms. Symptoms caused impairments at home, school, or with peers in 96.9% of the sample and across all three contexts in 64.0% of children. Sleep problems were also noted after three-day weekends and Spring and Fall Daylight Savings time changes. Findings, study limitations, and implications for treatment and etiology are discussed.
NASA Astrophysics Data System (ADS)
Grafton, R. Quentin; Ward, Michael B.; To, Hang; Kompas, Tom
2011-08-01
Household survey data for 10 countries are used to quantify and test the importance of price and nonprice factors on residential water demand and investigate complementarities between household water-saving behaviors and the average volumetric price of water. Results show (1) the average volumetric price of water is an important predictor of differences in residential consumption in models that include household characteristics, water-saving devices, attitudinal characteristics and environmental concerns as explanatory variables; (2) of all water-saving devices, only a low volume/dual-flush toilet has a statistically significant and negative effect on water consumption; and (3) environmental concerns have a statistically significant effect on some self-reported water-saving behaviors. While price-based approaches are espoused to promote economic efficiency, our findings stress that volumetric water pricing is also one of the most effective policy levers available to regulate household water consumption.
Daylight time-resolved photographs of lightning.
Qrville, R E; Lala, G G; Idone, V P
1978-07-07
Lightning dart leaders and return strokes have been recorded in daylight with both good spatial resolution and good time resolution as part of the Thunder-storm Research International Program. The resulting time-resolved photographs are apparently equivalent to the best data obtained earlier only at night. Average two-dimensional return stroke velocities in four subsequent strokes between the ground and a height of 1400 meters were approximately 1.3 x 10(8) meters per second. The estimated systematic error is 10 to 15 percent.
Hardware-in-the-Loop Modeling and Simulation Methods for Daylight Systems in Buildings
NASA Astrophysics Data System (ADS)
Mead, Alex Robert
This dissertation introduces hardware-in-the-loop modeling and simulation techniques to the daylighting community, with specific application to complex fenestration systems. No such application of this class of techniques, optimally combining mathematical-modeling and physical-modeling experimentation, is known to the author previously in the literature. Daylighting systems in buildings have a large impact on both the energy usage of a building as well as the occupant experience within a space. As such, a renewed interest has been placed on designing and constructing buildings with an emphasis on daylighting in recent times as part of the "green movement.''. Within daylighting systems, a specific subclass of building envelope is receiving much attention: complex fenestration systems (CFSs). CFSs are unique as compared to regular fenestration systems (e.g. glazing) in the regard that they allow for non-specular transmission of daylight into a space. This non-specular nature can be leveraged by designers to "optimize'' the times of the day and the days of the year that daylight enters a space. Examples of CFSs include: Venetian blinds, woven fabric shades, and prismatic window coatings. In order to leverage the non-specular transmission properties of CFSs, however, engineering analysis techniques capable of faithfully representing the physics of these systems are needed. Traditionally, the analysis techniques available to the daylighting community fall broadly into three classes: simplified techniques, mathematical-modeling and simulation, and physical-modeling and experimentation. Simplified techniques use "rules-of-thumb'' heuristics to provide insights for simple daylighting systems. Mathematical-modeling and simulation use complex numerical models to provide more detailed insights into system performance. Finally, physical-models can be instrumented and excited using artificial and natural light sources to provide performance insight into a daylighting system. Each class of techniques, broadly speaking however, has advantages and disadvantages with respect to the cost of execution (e.g. money, time, expertise) and the fidelity of the provided insight into the performance of the daylighting system. This varying tradeoff of cost and insight between the techniques determines which techniques are employed for which projects. Daylighting systems with CFS components, however, when considered for simulation with respect to these traditional technique classes, defy high fidelity analysis. Simplified techniques are clearly not applicable. Mathematical-models must have great complexity in order to capture the non-specular transmission accurately, which greatly limit their applicability. This leaves physical modeling, the most costly, as the preferred method for CFS. While mathematical-modeling and simulation methods do exist, they are in general costly and and still approximations of the underlying CFS behavior. Meaning in fact, measurements of CFSs are currently the only practical method to capture the behavior of CFSs. Traditional measurements of CFSs transmission and reflection properties are conducted using an instrument called a goniophotometer and produce a measurement in the form of a Bidirectional Scatter Distribution Function (BSDF) based on the Klems Basis. This measurement must be executed for each possible state of the CFS, hence only a subset of the possible behaviors can be captured for CFSs with continuously varying configurations. In the current era of rapid prototyping (e.g. 3D printing) and automated control of buildings including daylighting systems, a new analysis technique is needed which can faithfully represent these CFSs which are being designed and constructed at an increasing rate. Hardware-in-the-loop modeling and simulation is a perfect fit to the current need of analyzing daylighting systems with CFSs. In the proposed hardware-in-the-loop modeling and simulation approach of this dissertation, physical-models of real CFSs are excited using either natural or artificial light. The exiting luminance distribution from these CFSs is measured and used as inputs to a Radiance mathematical-model of the interior of the space, which is proposed to be lit by the CFS containing daylighting system. Hence, the components of the total daylighting and building system which are not mathematically-modeled well, the CFS, are physically excited and measured, while the components which are modeled properly, namely the interior building space, are mathematically-modeled. In order to excite and measure CFSs behavior, a novel parallel goniophotometer, referred to as the CUBE 2.0, is developed in this dissertation. The CUBE 2.0 measures the input illuminance distribution and the output luminance distribution with respect to a CFS under test. Further, the process is fully automated allowing for deployable experiments on proposed building sites, as well as in laboratory based experiments. In this dissertation, three CFSs, two commercially available and one novel--Twitchell's Textilene 80 Black, Twitchell's Shade View Ebony, and Translucent Concrete Panels (TCP)--are simulated on the CUBE 2.0 system for daylong deployments at one minute time steps. These CFSs are assumed to be placed in the glazing space within the Reference Office Radiance model, for which horizontal illuminance on a work plane of 0.8 m height is calculated for each time step. While Shade View Ebony and TCPs are unmeasured CFSs with respect to BSDF, Textilene 80 Black has been previously measured. As such a validation of the CUBE 2.0 using the goniophotometer measured BSDF is presented, with measurement errors of the horizontal illuminance between +3% and -10%. These error levels are considered to be valid within experimental daylighting investigations. Non-validated results are also presented in full for both Shade View Ebony as well as TCP. Concluding remarks and future directions for HWiL simulation close the dissertation.
Tomás-Velázquez, A; Redondo, P
2017-05-01
Actinic keratosis is a precursor lesion to the most common nonmelanoma skin cancer. Conventional photodynamic therapy (PDT) has been shown to be effective, but the procedure is time-consuming, can be very painful, and requires infrastructure. These shortcomings led to the emergence of daylight PDT. To obtain a global estimate of efficacy, we undertook a systematic literature review and performed a meta-analysis of the available evidence on the efficacy and safety of daylight PDT as compared to conventional PDT in the treatment of actinic keratosis and/or field cancerization. The conclusion is that the difference in efficacy is clinically negligible (global estimate of the mean response rate difference, -3.69%; 95% CI, -6.54% to -0.84%). The adverse effects of daylight PDT are mild and localized (79% of patients report no discomfort), and patients report less pain (P<.001). Daylight PDT gives good to excellent cosmetic results in more than 90% of patients, and patient satisfaction is greater (P<.001). Copyright © 2016 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.
Will Renewable Energy Save Our Planet?
NASA Astrophysics Data System (ADS)
Bojić, Milorad
2010-06-01
This paper discusses some important fundamental issues behind application of renewable energy (RE) to evaluate its impact as a climate change mitigation technology. The discussed issues are the following: definition of renewable energy, concentration of RE by weight and volume, generation of electrical energy and its power at unit area, electrical energy demand per unit area, life time approach vs. layman approach, energy return time, energy return ratio, CO2 return time, energy mix for RES production and use, geographical distribution of RES use, huge scale of energy shift from RES to non-RES, increase in energy consumption, Thermodynamic equilibrium of earth, and probable solutions for energy future of our energy and environmental crisis of today. The future solution (that would enable to human civilization further welfare, and good living, but with lower release of CO2 in atmosphere) may not be only RES. This will rather be an energy mix that may contain nuclear energy, non-nuclear renewable energy, or fossil energy with CO2 sequestration, efficient energy technologies, energy saving, and energy consumption decrease.
Yang, Min; Li, Ya-ming; Wei, Yuan-song; Lü, Jian; Yu, Da-wei; Liu, Ji-bao; Fan, Yao-bo
2015-06-01
Energy consumption is the main performance indicator of reclaimed water plant (RWP) operation. Methods of specific energy consumption analysis, unit energy consumption analysis and redundancy analysis were applied to investigate the composition and spatio-temporal distribution of energy consumption in Qinghe RWP with inverted A2/O, A2/O and A2/O-MBR processes. And the A2/ O-MBR process was mainly analyzed to identify the main nodes and causes for high energy consumption, approaches for energy saving were explored, and the energy consumption before and after upgrading for energy saving was compared. The results showed that aeration was the key factor affecting energy consumption in both conventional and A2/O-MBR processes, accounting for 42.97% and 50.65% of total energy consumption, respectively. A pulsating aeration allowed an increasing membrane flux and remarkably reduced the energy consumption of the A2/O-MBR process while still meeting the effluent standard, e.g., the membrane flux was increased by 20%, and the energy consumptions per kiloton wastewater and kilogram COD(removed) were decreased by 42.39% to 0.53 kW-h-kg-3 and by 54.74% to 1.29 kW x h x kg(-1), respectively. The decrease of backflow ratio in the A2/O-MBR process within a certain range would not deteriorate the effluent quality due to its insignificant correlation with the effluent quality, and therefore may be considered as one of the ways for further energy saving.
NASA Astrophysics Data System (ADS)
Wadsworth, Adam J.
A method for passively detecting and imaging underwater targets using ambient noise as the sole source of illumination (named acoustic daylight) was successfully implemented in the form of the Acoustic Daylight Ocean Noise Imaging System (ADONIS). In a series of imaging experiments conducted in San Diego Bay, where the dominant source of high-frequency ambient noise is snapping shrimp, a large quantity of ambient noise intensity data was collected with the ADONIS (Epifanio, 1997). In a subset of the experimental data sets, fluctuations of time-averaged ambient noise intensity exhibited a diurnal pattern consistent with the increase in frequency of shrimp snapping near dawn and dusk. The same subset of experimental data is revisited here and the correlation time is estimated and analysed for sequences of ambient noise data several minutes in length, with the aim of detecting possible periodicities or other trends in the fluctuation of the shrimp-dominated ambient noise field. Using videos formed from sequences of acoustic daylight images along with other experimental information, candidate segments of static-configuration ADONIS raw ambient noise data were isolated. For each segment, the normalized intensity auto-correlation closely resembled the delta function, the auto-correlation of white noise. No intensity fluctuation patterns at timescales smaller than a few minutes were discernible, suggesting that the shrimp do not communicate, synchronise, or exhibit any periodicities in their snapping. Also presented here is a ADONIS-specific target recognition algorithm based on principal component analysis, along with basic experimental results using a database of acoustic daylight images.
Use of Daylight and Aesthetic Image of Glass Facades in Contemporary Buildings
NASA Astrophysics Data System (ADS)
Roginska-Niesluchowska, Malgorzata
2017-10-01
The paper deals with the architecture of contemporary buildings in respect to their aesthetic image created by the use of natural light. Sustainability is regarded as a governing principle of contemporary architecture, where daylighting is an important factor as it affects energy consumption and environmental quality of the space inside a building. Environmental awareness of architecture, however, involves a much wider and more holistic view of design. The quality of sustainable architecture can be considered in its aesthetic and cultural context with regard to landscape, local tradition, and connection to the surrounding world. This approach is associated with the social mission of architecture, i.e. providing appropriate space for living, facilitating social relations and having positive impact on people. The purpose of the research is to study the use of daylight in creating an aesthetic image of contemporary buildings. The author focuses mainly on public buildings largely dedicated to art and culture which satisfy high functional and aesthetic requirements. The paper examines the genesis and current trends in the aesthetic image of modern buildings which use daylight as the main design strategy, focusing on the issues of glass facades. The main attention is given to the shaping of representative public areas which feature the glass facades. The research has been based on a case study, critical review of literature review, observation and synthesis. The study identifies and classifies different approaches to using daylight in these areas and highlights changes in the aesthetics of architecture made of glass, which uses daylight as the main design strategy. These changes are primarily caused by the development and spreading of new glazing materials and the use of digital method of design. The influence of light and its mode depends on glass materials but also on the local conditions of the site, and has a significant impact on the relationship between architecture and its natural and cultural environment. The subordination of architectural concept to the idea of natural lighting builds the relationship between form, function and the context of architecture, and is expressed in its structural, material and spatial properties, and in the resulting aesthetic order. Search for new architectural solutions is defined by local topographical, climatic, biological and cultural conditions. The architecture subordinate to the conception of contribution of light corresponds to the aesthetic aspirations of sustainability.
Energy Savings by Treating Buildings as Systems
NASA Astrophysics Data System (ADS)
Harvey, L. D. Danny
2008-09-01
This paper reviews the opportunities for dramatically reducing energy use in buildings by treating buildings as systems, rather than focusing on device efficiencies. Systems-level considerations are relevant for the operation of heat pumps (where the temperatures at which heat or coldness are distributed are particularly important); the joint or separate provision of heating, cooling, and ventilation; the joint or separate removal of sensible heat and moisture; and in the operation of fluid systems having pumps. Passive heating, cooling, and ventilation, as well as daylighting (use of sunlight for lighting purposes) also require consideration of buildings as systems. In order to achieve the significant (50-75%) energy savings that are possible through a systems approach, the design process itself has to involve a high degree of integration between the architect and various engineering disciplines (structural, mechanical, electrical), and requires the systematic examination and adjustment of alternative designs using computer simulation models.
Energy Savings Potential of SSL in Horticultural Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stober, Kelsey; Lee, Kyung; Yamada, Mary
Report that presents the findings for horticultural lighting applications where light-emitting diode (LED) products are now competing with traditional light sources. The three main categories of indoor horticulture were investigated: supplemented greenhouses, which use electric lighting to extend the hours of daylight, supplement low levels of sunlight on cloudy days, or disrupt periods of darkness to alter plant growth; non-stacked indoor farms, where plants are grown in a single layer on the floor under ceiling-mounted lighting; and vertical farms, where plants are stacked along vertical shelving to maximize grow space, and the lighting is typically mounted within the shelving units.
NASA Technical Reports Server (NTRS)
Klassen, Steve; Bugbee, Bruce
2005-01-01
Accurate shortwave radiation data is critical to evapotranspiration (ET) models used for developing irrigation schedules to optimize crop production while saving water, minimizing fertilizer, herbicide, and pesticide applications, reducing soil erosion, and protecting surface and ground water quality. Low cost silicon cell pyranometers have proven to be sufficiently accurate and robust for widespread use in agricultural applications under unobstructed daylight conditions. More expensive thermopile pyranometers are required for use as calibration standards and measurements under light with unique spectral properties (electric lights, under vegetation, in greenhouses and growth chambers). Routine cleaning, leveling, and annual calibration checks will help to ensure the integrity of long-term data.
Tachinardi, Patricia; Valentinuzzi, Verónica S; Oda, Gisele A; Buck, C Loren
The tuco-tuco (Ctenomys aff. knighti) is among the rodent species known to be nocturnal under standard laboratory conditions and diurnal under natural conditions. The circadian thermoenergetics (CTE) hypothesis postulates that switches in activity timing are a response to energetic challenges; daytime activity reduces thermoregulatory costs by consolidating activity to the warmest part of the day. Studying wild animals under both captive and natural conditions can increase understanding of how temporal activity patterns are shaped by the environment and could serve as a test of the CTE hypothesis. We estimated the effects of activity timing on energy expenditure for the tuco-tuco by combining laboratory measurements of metabolic rate with environmental temperature records in both winter and summer. We showed that, in winter, there would be considerable energy savings if activity is allocated at least partially during daylight, lending support to the CTE hypothesis. In summer, the impact of activity timing on energy expenditure is small, suggesting that during this season other factors, such as predation risk, water balance, and social interaction, may have more important roles than energetics in the determination of activity time.
ERIC Educational Resources Information Center
Heschong, Lisa
This study examines the effect of daylighting on human performance, focusing on skylighting as a way to isolate daylight as an illumination source, and separate illumination effects from other qualities associated with daylighting from windows. It establishes a statistical connection between daylighting and student performance and between…
Wireless network interface energy consumption implications of popular streaming formats
NASA Astrophysics Data System (ADS)
Chandra, Surendar
2001-12-01
With the proliferation of mobile streaming multimedia, available battery capacity constrains the end-user experience. Since streaming applications tend to be long running, wireless network interface card's (WNIC) energy consumption is particularly an acute problem. In this work, we explore the WNIC energy consumption implications of popular multimedia streaming formats from Microsoft (Windows media), Real (Real media) and Apple (Quick Time). We investigate the energy consumption under varying stream bandwidth and network loss rates. We also explore history-based client-side strategies to reduce the energy consumed by transitioning the WNICs to a lower power consuming sleep state. We show that Microsoft media tends to transmit packets at regular intervals; streams optimized for 28.8 Kbps can save over 80% in energy consumption with 2% data loss. A high bandwidth stream (768 Kbps) can still save 57% in energy consumption with less than 0.3% data loss. For high bandwidth streams, Microsoft media exploits network-level packet fragmentation, which can lead to excessive packet loss (and wasted energy) in a lossy network. Real stream packets tend to be sent closer to each other, especially at higher bandwidths. Quicktime packets sometimes arrive in quick succession; most likely an application level fragmentation mechanism. Such packets are harder to predict at the network level without understanding the packet semantics.
Effect of dividing daylight in symmetric prismatic daylight collector
NASA Astrophysics Data System (ADS)
Yeh, Shih-Chuan; Lu, Ju-Lin; Cheng, Yu-Chin
2017-04-01
This paper presented a symmetric prismatic daylight collector to collect daylight for the natural light illumination system. We analyzed the characteristics of the emerging light when the parallel light beam illuminate on the horizontally placed symmetric prismatic daylight collector. The ratio of the relative intensities of collected daylight that emerging from each surface of the daylight collector shown that the ratio is varied with the incident angle during a day. The simulation of the emerging light of the daylight collector shown that the ratio of emerging light is varied with the tilted angle when sunshine illuminated on a symmetric prismatic daylight collector which was not placed horizontally. The integration of normalized intensity is also varied with the tilted angle. The symmetric prismatic daylight collector with the benefits of reducing glare and dividing intensity of incident daylight, it is applicable to using in the natural light illumination system and hybrid system for improving the efficiency of utilizing of solar energy.
29 CFR Appendix to Subpart B of... - Reporter's Notes
Code of Federal Regulations, 2010 CFR
2010-07-01
... ascertainment of the truth, (2) avoid needless consumption of time, and (3) protect witnesses from harassment or... * * * may justify a broader approach. Under it, an agency may be permitted to take ‘official notice’ not... notice of ‘facts.’ Here Wigmore, following Thayer, insists that judicial notice is solely to save time...
Obituary: Ian R. Bartky, 1934-2007
NASA Astrophysics Data System (ADS)
Dick, Steven J.
2009-01-01
Ian Robertson Bartky, a physical chemist who turned to history for his second career, died 18 December 2007 of complications from lung cancer. He was 73. In addition to his scientific career, he will be remembered for his meticulous research on the evolution of time systems, especially for his two books Selling the True Time: Nineteenth Century Timekeeping in America (Stanford University Press, 2000), and One Time Fits All: The Campaigns for Global Uniformity (Stanford University Press, 2007). Ian was born on 15 March 1934 in Chicago, Illinois. He was the son of Walter Bartky, a Professor of Astronomy at the University of Chicago, and eventually its Dean of the Division of Physical Sciences. The elder Bartky's astronomy textbook, Highlights of Astronomy, published in 1935 and reprinted as late as 1964, includes a considerable discussion of time and standard meridians, which may have influenced Ian, even though his father died in 1958 at the age of 57 when Ian would have been only in his early 20s. Imbued with the love of science from his father, Ian graduated from Illinois Institute of Technology, and went on to obtain his doctorate in physical chemistry from the University of California Berkeley. He mentor was Nobelist William F. Giauque, and Ian always spoke fondly of Giauque's influence in setting rigorous standards that Ian followed when he joined the National Bureau of Standards [NBS] in 1961. Ian spent most of his career there, and it was there that he acquired his professional interest in time, notably when the House Commerce Committee asked him in the mid-1970s to determine whether the dates of Daylight Saving Time should be extended. This resulted in an NBS report in 1976, which concluded that any energy savings would be miniscule. With his usual attention to detail, Ian researched the entire history of the problem, and thus acquired his second great love after science--history. With Elizabeth Harrison he published a well-known article on the issues involved with Daylight Saving Time in Scientific American for 1979. My first interaction with Ian was leading up to the 150th anniversary of the United States Naval Observatory [USNO] in December 1980. While working on an article for Sky and Telescope on the early history of the Naval Observatory, I ran across documents in the National Archives from England proposing that the Navy's new Depot of Charts and Instruments--forerunner of the Observatory--erect a time ball as had been done in Portsmouth England in 1829. Ian had been in the National Archives working on the history of time. When I mentioned this 1829 document, he said it was impossible, because the first time ball in the world was in 1833 at Greenwich, England. But the documents told the story, and this Eureka moment led to our article in the Journal for the History of Astronomy (volume 12, October 1981), on the world's first time ball. This was to the considerable chagrin of the staff at Greenwich, who thought they had the world's first time ball, and who still ceremonially drop one at 1 PM local time. Ian went on to write the history of time balls for the Naval Observatory's sesquicentennial symposium at the end of 1980, as published in Sky with Ocean Joined. We then collaborated on another article for JHA (volume 13, February 1982) on the history of the first North American time ball, dropped at the USNO beginning in 1845. Time balls and Daylight Saving Time were only a small part of Ian's interest in time as he began to untangle the many issues involved in the history of timekeeping and time dissemination. His book Selling the True Time is a model of scholarship, and with it Ian proved to have that rare combination--a scientist with deep technical knowledge who could also ask and answer profound historical questions. He also had a keen appreciation of the role of human nature in history, always looking for the motivations for particular historical actions. Ian was proud to have the book published by Stanford University Press. When Stanford also published his final book One Time Fits All: The Campaigns for Global Uniformity, he was very proud of the glowing endorsement from Peter Galison, one of the country's foremost historians of science. With this book Ian also became the world's expert on the International Date Line, time zones, and standard time, among other aspects of time. Ian's historical work was supported by the National Science Foundation, the Dudley Observatory, and the National Maritime Museum of the Royal Observatory at Greenwich, where his work was highly regarded. He was active in many professional organizations, including the Historical Astronomy Division of the American Astronomical Society. On 29 March 2008 almost exactly 50 years after the death of his father, a memorial service was held in the library of the U. S. Naval Observatory, which had become Ian's second home during his researches, often accompanied by his wife Betty, to whom he dedicated his last book, calling her his "steadfast partner in this endeavor." The service, entitled "The Time of His Life: A Celebration of Research in the Development of Standard Timekeeping," included remarks by numerous colleagues and friends, surrounded by the books he so loved. Ian is survived by his wife of 47 years, Elizabeth Hodgins Bartky of Bethesda, Maryland, a son David J. Bartky, and a daughter Anne B. Goldberg.
Trivedi, Amit K; Rani, Sangeeta; Kumar, Vinod
2006-01-01
Background A stable and systematic daily change in light levels at dawn and dusk provides the most reliable indicator of the phase of the day. It is likely that organisms have evolved mechanisms to use these twilight transitions as the primary zeitgeber to adjust their circadian phases. In this study, we investigated under natural illumination conditions the effects of daylight exposure restricted to twilights on the timing of testicular regression and locomotor activity of the house sparrow (Passer domesticus), which possesses a strongly self-sustaining circadian system. Methods and results Two experiments were performed on adult male house sparrows. Beginning in the third week of April, the first experiment examined whether exposure to natural daylight only during twilights influenced the timing of testicular regression and concomitant changes in testosterone-dependent beak color of reproductively mature sparrows. Interestingly, there was a significant delay in testicular regression and depigmentation of the beak in sparrows exposed to natural daylight (NDL) only during twilights as compared to those exposed to NDL all day. The second experiment examined twice in the year, around the equinoxes (March and September), the effects of exposure to twilights only on the daily activity rhythm of sparrows kept in an outdoor aviary. Five of 7 birds continued exhibiting entrained activity rhythms when exposed only to twilights (NDL minus day light from sunrise to sunset) in September, but not in March. Both in NDL and twilight conditions, March birds had significantly lower activity counts than September birds. Conclusion Exposure to natural daylight only during twilights delayed the timing of testicular regression and concomitant depigmentation of the beak but did not affect the daily activity rhythm in male sparrows. This suggests that daily twilights can serve as cues for regulation of the circadian activity rhythm but not for the photoperiodic regulation of testicular cycle in the house sparrow. PMID:16553964
Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario
2014-01-01
This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677
A high performance load balance strategy for real-time multicore systems.
Cho, Keng-Mao; Tsai, Chun-Wei; Chiu, Yi-Shiuan; Yang, Chu-Sing
2014-01-01
Finding ways to distribute workloads to each processor core and efficiently reduce power consumption is of vital importance, especially for real-time systems. In this paper, a novel scheduling algorithm is proposed for real-time multicore systems to balance the computation loads and save power. The developed algorithm simultaneously considers multiple criteria, a novel factor, and task deadline, and is called power and deadline-aware multicore scheduling (PDAMS). Experiment results show that the proposed algorithm can greatly reduce energy consumption by up to 54.2% and the deadline times missed, as compared to the other scheduling algorithms outlined in this paper.
A High Performance Load Balance Strategy for Real-Time Multicore Systems
Cho, Keng-Mao; Tsai, Chun-Wei; Chiu, Yi-Shiuan; Yang, Chu-Sing
2014-01-01
Finding ways to distribute workloads to each processor core and efficiently reduce power consumption is of vital importance, especially for real-time systems. In this paper, a novel scheduling algorithm is proposed for real-time multicore systems to balance the computation loads and save power. The developed algorithm simultaneously considers multiple criteria, a novel factor, and task deadline, and is called power and deadline-aware multicore scheduling (PDAMS). Experiment results show that the proposed algorithm can greatly reduce energy consumption by up to 54.2% and the deadline times missed, as compared to the other scheduling algorithms outlined in this paper. PMID:24955382
NASA Astrophysics Data System (ADS)
Cory, Bradley S.
The reEnergize Program conducted 957 energy upgrades in Omaha Nebraska from July 2010 to September 30th 2013, through a government grant within the Better Buildings Neighborhood Program. Projected program savings were provided upon program completion but it was unknown how effective the program was at actually reducing energy consumption in the homes that were upgraded. The following research report uses a PRISM analysis to remove the effect of weather and compare the actual pre and post utility usage rates to determine the actual effectiveness of the program. The housing characteristics, and individual energy upgrades were analyzed to see if any patterns or trends could be identified between consumption savings and housing type and specific upgrade measure. The results of the study showed that the program did induce savings but by much less than the engineering estimates predicted. It is likely that housing characteristics and upgrade measures play a role in inducing consumption savings but homeowner behavior is a stronger factor that influences savings.
Javanbakht, Mehdi; Jamshidi, Ahmad Reza; Baradaran, Hamid Reza; Mohammadi, Zahra; Mashayekhi, Atefeh; Shokraneh, Farhad; Rezai Hamami, Mohsen; Yazdani Bakhsh, Raziyeh; Shabaninejad, Hossien; Delavari, Sajad; Tehrani, Arash
2018-05-01
Recent evidence from prospective cohort studies show a relationship between consumption of dairy foods and cardiovascular diseases (CVDs) and type 2 diabetes mellitus (T2DM). This association highlights the importance of dairy foods consumption in prevention of these diseases and also reduction of associated healthcare costs. The aim of this study was to estimate avoidable healthcare costs of CVD and T2D through adequate dairy foods consumption in Iran. This was a multistage modelling study. We conducted a systematic literature review in PubMed and EMBASE to identify any association between incidence of CVD and T2DM and dairy foods intake, and also associated relative risks. We obtained age- and sex-specific dairy foods consumption level and healthcare expenditures from national surveys and studies. Patient level simulation Markov models were constructed to predict the disease incidence, patient population size and associated healthcare costs for current and optimal dairy foods consumption at different time horizons (1, 5, 10 and 20 years). All parameters including costs and transition probabilities were defined as statistical distributions in the models, and all analyses were conducted by accounting for first and second order uncertainty. The systematic review results indicated that dairy foods consumption was inversely associated with incidence of T2DM, coronary heart disease (CHD) and stroke. We estimated that the introduction of a diet containing 3 servings of dairy foods per day may produce a $0.43 saving in annual per capita healthcare costs in Iran in the first year due to saving in cost of CVD and T2DM treatment. The estimated savings in per capita healthcare costs were $8.42, $39.97 and $190.25 in 5, 10 and 20-years' time, respectively. Corresponding total aggregated avoidable costs for the entire Iranian population within the study time horizons were $33.83, $661.31, $3,138.21 and $14,934.63 million, respectively. Our analysis demonstrated that increasing dairy foods consumption to recommended levels would be associated with reductions in healthcare costs. Further randomized trial studies are required to investigate the effect of dairy foods intake on cost of CVD and T2DM in the population. © 2018 The Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Personal Retirement Accounts and Saving†
Aguila, Emma
2017-01-01
Aging populations are leading countries worldwide to social security reforms. Many countries are moving from pay-as-you-go to personal retirement account (PRA) systems because of their financial sustainability and positive impact on private savings. PRA systems boost private savings at a macro level by converting a government liability into financial wealth managed by private fund managers. However, at a micro level, changes in retirement wealth affect individuals' saving and consumption patterns through their working lives. Retirement wealth increased for lower-income workers after Mexico introduced PRAs, crowding out saving, increasing consumption, and offsetting some of the PRA effect on private savings. (JEL D14, E21, H55, J26, O16) PMID:28286607
NASA Astrophysics Data System (ADS)
Spang, Edward S.; Holguin, Andrew J.; Loge, Frank J.
2018-01-01
In April 2015, the Governor of California mandated a 25% statewide reduction in water consumption (relative to 2013 levels) by urban water suppliers. The more than 400 public water agencies affected by the regulation were also required to report monthly progress towards the conservation goal to the State Water Resources Control Board. This paper uses the reported data to assess how the water utilities have responded to this mandate and to estimate the electricity savings and greenhouse gas (GHG) emissions reductions associated with reduced operation of urban water infrastructure systems. The results show that California succeeded in saving 524 000 million gallons (MG) of water (a 24.5% decrease relative to the 2013 baseline) over the mandate period, which translates into 1830 GWh total electricity savings, and a GHG emissions reduction of 521 000 metric tonnes of carbon dioxide equivalents (MT CO2e). For comparison, the total electricity savings linked to water conservation are approximately 11% greater than the savings achieved by the investor-owned electricity utilities’ efficiency programs for roughly the same time period, and the GHG savings represent the equivalent of taking about 111 000 cars off the road for a year. These indirect, large-scale electricity and GHG savings were achieved at costs that were competitive with existing programs that target electricity and GHG savings directly and independently. Finally, given the breadth of the results produced, we built a companion website, called ‘H2Open’ (https://cwee.shinyapps.io/greengov/), to this research effort that allows users to view and explore the data and results across scales, from individual water utilities to the statewide summary.
Playback system designed for X-Band SAR
NASA Astrophysics Data System (ADS)
Yuquan, Liu; Changyong, Dou
2014-03-01
SAR(Synthetic Aperture Radar) has extensive application because it is daylight and weather independent. In particular, X-Band SAR strip map, designed by Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, provides high ground resolution images, at the same time it has a large spatial coverage and a short acquisition time, so it is promising in multi-applications. When sudden disaster comes, the emergency situation acquires radar signal data and image as soon as possible, in order to take action to reduce loss and save lives in the first time. This paper summarizes a type of X-Band SAR playback processing system designed for disaster response and scientific needs. It describes SAR data workflow includes the payload data transmission and reception process. Playback processing system completes signal analysis on the original data, providing SAR level 0 products and quick image. Gigabit network promises radar signal transmission efficiency from recorder to calculation unit. Multi-thread parallel computing and ping pong operation can ensure computation speed. Through gigabit network, multi-thread parallel computing and ping pong operation, high speed data transmission and processing meet the SAR radar data playback real time requirement.
NASA Astrophysics Data System (ADS)
Wei, Wang; Chongchao, Pan; Yikai, Liang; Gang, Li
2017-11-01
With the rapid development of information technology, the scale of data center increases quickly, and the energy consumption of computer room also increases rapidly, among which, energy consumption of air conditioning cooling makes up a large proportion. How to apply new technology to reduce the energy consumption of the computer room becomes an important topic of energy saving in the current research. This paper study internet of things technology, and design a kind of green computer room environmental monitoring system. In the system, we can get the real-time environment data from the application of wireless sensor network technology, which will be showed in a creative way of three-dimensional effect. In the environment monitor, we can get the computer room assets view, temperature cloud view, humidity cloud view, microenvironment view and so on. Thus according to the condition of the microenvironment, we can adjust the air volume, temperature and humidity parameters of the air conditioning for the individual equipment cabinet to realize the precise air conditioning refrigeration. And this can reduce the energy consumption of air conditioning, as a result, the overall energy consumption of the green computer room will reduce greatly. At the same time, we apply this project in the computer center of Weihai, and after a year of test and running, we find that it took a good energy saving effect, which fully verified the effectiveness of this project on the energy conservation of the computer room.
Fleischman, Ross J.; Lundquist, Mark; Jui, Jonathan; Newgard, Craig D.; Warden, Craig
2014-01-01
Objective To derive and validate a model that accurately predicts ambulance arrival time that could be implemented as a Google Maps web application. Methods This was a retrospective study of all scene transports in Multnomah County, Oregon, from January 1 through December 31, 2008. Scene and destination hospital addresses were converted to coordinates. ArcGIS Network Analyst was used to estimate transport times based on street network speed limits. We then created a linear regression model to improve the accuracy of these street network estimates using weather, patient characteristics, use of lights and sirens, daylight, and rush-hour intervals. The model was derived from a 50% sample and validated on the remainder. Significance of the covariates was determined by p < 0.05 for a t-test of the model coefficients. Accuracy was quantified by the proportion of estimates that were within 5 minutes of the actual transport times recorded by computer-aided dispatch. We then built a Google Maps-based web application to demonstrate application in real-world EMS operations. Results There were 48,308 included transports. Street network estimates of transport time were accurate within 5 minutes of actual transport time less than 16% of the time. Actual transport times were longer during daylight and rush-hour intervals and shorter with use of lights and sirens. Age under 18 years, gender, wet weather, and trauma system entry were not significant predictors of transport time. Our model predicted arrival time within 5 minutes 73% of the time. For lights and sirens transports, accuracy was within 5 minutes 77% of the time. Accuracy was identical in the validation dataset. Lights and sirens saved an average of 3.1 minutes for transports under 8.8 minutes, and 5.3 minutes for longer transports. Conclusions An estimate of transport time based only on a street network significantly underestimated transport times. A simple model incorporating few variables can predict ambulance time of arrival to the emergency department with good accuracy. This model could be linked to global positioning system data and an automated Google Maps web application to optimize emergency department resource use. Use of lights and sirens had a significant effect on transport times. PMID:23865736
Electric energy savings from new technologies. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.
1986-09-01
Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for 10 technologies were prepared. The total projected annual savings for the year 2000 for all 10 technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In themore » Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference projection, only 25% of the savings estimated here should be subtracted from the reference projection for analysis purposes.« less
29 CFR Appendix to Subpart B of... - Reporter's Notes
Code of Federal Regulations, 2012 CFR
2012-07-01
... ascertainment of the truth, (2) avoid needless consumption of time, and (3) protect witnesses from harassment or... notice of ‘facts.’ Here Wigmore, following Thayer, insists that judicial notice is solely to save time... to Federal Rule of Evidence 302, 56 F.R.D. 118, 211 states: A series of Supreme Court decisions in...
29 CFR Appendix to Subpart B of... - Reporter's Notes
Code of Federal Regulations, 2011 CFR
2011-07-01
... ascertainment of the truth, (2) avoid needless consumption of time, and (3) protect witnesses from harassment or... notice of ‘facts.’ Here Wigmore, following Thayer, insists that judicial notice is solely to save time... to Federal Rule of Evidence 302, 56 F.R.D. 118, 211 states: A series of Supreme Court decisions in...
29 CFR Appendix to Subpart B of... - Reporter's Notes
Code of Federal Regulations, 2013 CFR
2013-07-01
... ascertainment of the truth, (2) avoid needless consumption of time, and (3) protect witnesses from harassment or... notice of ‘facts.’ Here Wigmore, following Thayer, insists that judicial notice is solely to save time... to Federal Rule of Evidence 302, 56 F.R.D. 118, 211 states: A series of Supreme Court decisions in...
29 CFR Appendix to Subpart B of... - Reporter's Notes
Code of Federal Regulations, 2014 CFR
2014-07-01
... ascertainment of the truth, (2) avoid needless consumption of time, and (3) protect witnesses from harassment or... notice of ‘facts.’ Here Wigmore, following Thayer, insists that judicial notice is solely to save time... to Federal Rule of Evidence 302, 56 F.R.D. 118, 211 states: A series of Supreme Court decisions in...
A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings
Tseng, Yen-Chieh; Lee, Da-Sheng; Lin, Cheng-Fang; Chang, Ching-Yuan
2013-01-01
It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building. PMID:23698273
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Zhiming; Lin, Zhenhong; Franzese, Oscar
This paper evaluates the application of battery electric vehicles (BEVs) and genset plug-in hybrid electric vehicles (PHEVs) to Class-7 local delivery trucks and genset PHEV for Class-8 utility bucket trucks over widely real-world driving data performed by conventional heavy-duty trucks. A simulation tool based on vehicle tractive energy methodology and component efficiency for addressing component and system performance was developed to evaluate the energy consumption and performance of the trucks. As part of this analysis, various battery sizes combined with different charging powers on the E-Trucks for local delivery and utility bucket applications were investigated. The results show that themore » E-Truck applications not only reduce energy consumption but also achieve significant energy cost savings. For delivery E-Trucks, the results show that periodic stops at delivery sites provide sufficient time for battery charging, and for this reason, a high-power charger is not necessary. For utility bucket PHEV trucks, energy consumption per mile of bucket truck operation is typically higher because of longer idling times and extra high idling load associated with heavy utility work. The availability of on-route charging is typically lacking at the work sites of bucket trucks; hence, the battery size of these trucks is somewhat larger than that of the delivery trucks studied.« less
Student Understanding of Time in an Introductory Astronomy Laboratory
NASA Astrophysics Data System (ADS)
Traxler, A. L.; Batuski, D. J.; Comins, N. F.; Thompson, J. R.
2005-09-01
The astronomy lab at the University of Maine consists of discrete weekly lessons in which students work in small groups. Individual pretests and post-tests accompany each lesson. The lesson studied here covers the topic of time, including sidereal time, Apparent Solar Time, and time zones. The pretest consists of four multiple-choice questions, which are also administered after instruction as a post-test. In the fall 2004 semester, the pretest was rewritten to focus on some major conceptual components of the lab, while the lesson materials were not modified from previous years. Examination of class performance (n = 96) revealed no significant improvements in score from pre- to post-lesson. In the spring 2005 semester, the lesson was altered to incorporate the Starry Night software for simulating the sky instead of the celestial sphere models previously used. The goal of the change was to give students a more interactive environment for completing the laboratory exercise, which was otherwise altered as little as possible. Data from the spring semester show some gains on the pre/post-test questions covering sidereal time and Daylight Savings Time. Results to date have informed planned modifications to the lesson. A. L. T. was supported during this research by the University of Maine through a Provost Fellowship.
ERIC Educational Resources Information Center
Gleed, Amy Keller
2009-01-01
Daylighting a space is both an art and a science. The impact of daylight can make a building's design come to life. Daylighting can be carried out skillfully, or it can be too casually considered or totally misunderstood. Bad daylighting is devastating to a space and costly to fix. Today, in this era of sustainable design, daylighting is given…
NASA Astrophysics Data System (ADS)
Zhong, X. Y.; Gao, J. X.; Ren, H.; Cai, W. G.
2018-04-01
The acceleration of the urbanization process has brought new opportunities for China’s development. With the rapid economic development and people’s living standards improving, building energy consumption also showed a rigid growth trend. With the continuous improvement of the level of industrialization, industrial energy-saving potential declines. The construction industry to bear the task of energy-saving emission reduction will face more severe challenges. As the three municipalities of China, Beijing, Shanghai and Chongqing have significant radiation effects in the economy, urbanization level and construction industry development of the region. Therefore, it is of great significance to study the building energy consumption in the three regions with the change of urbanization level and the key factors. Based on the data of Beijing, Shanghai and Chongqing from 2001 to 2015, this paper attempts to find out whether the EKC curve of building energy consumption exists. At the same time, based on the results of the model, the data of the three regions are divided into three periods. The exponential decomposition method (LMDI) is used to find out the factors that have the greatest impact on the energy consumption of buildings in different stages. Moreover, analyzes the policy background of each stage and puts forward some policy suggestions on this basis.
Data on European non-residential buildings.
D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo
2017-10-01
This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.
Energy monitoring system based on human activity in the workplace
NASA Astrophysics Data System (ADS)
Mustafa, Nur Hanim; Husain, Mohd Nor; Aziz, Mohamad Zoinol Abidin Abdul; Othman, Mohd Azlishah; Malek, Fareq
2015-05-01
Human behaviors always related to day routine activities in a smart house directly give the significant factor to manage energy usage in human life. An Addition that, the factor will contribute to the best efficiency of the system. This paper will focus on the monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior at working place. Besides that, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy saving based on human behaviors. This scenario will help to see the human activity in the workplace in order to get the energy saving and support world green environment.
NASA Astrophysics Data System (ADS)
Berman, Samuel
1985-11-01
Advances in research for new types of lighting with increased efficacies (lumens/watt) are discussed in the following areas: (1) high-frequency, solid-state ballasts, (2) isotopic enhancement of mercury isotopes, (3) magnetic augmentation, (4) electrodeless, ultra-high frequency, (5) tuned phosphors, (6) two-photon phosphors, (7) heat mirrors, and (8) advanced control circuits to take advantage of daylight and occupancy. As of 1985, improvements in efficacy have been accomplished on an economic basis to save energy for (1) high frequency ballasts (25%), (2) isotopic enhancement (5%), and (8) advanced control circuits (up to 50%). Most of these advances depend on a deeper understanding of the weakly ionized plasma as a radiating and diffusing medium.
Strategies to Save 50% Site Energy in Grocery and General Merchandise Stores
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirsch, A.; Hale, E.; Leach, M.
2011-03-01
This paper summarizes the methodology and main results of two recently published Technical Support Documents. These reports explore the feasibility of designing general merchandise and grocery stores that use half the energy of a minimally code-compliant building, as measured on a whole-building basis. We used an optimization algorithm to trace out a minimum cost curve and identify designs that satisfy the 50% energy savings goal. We started from baseline building energy use and progressed to more energy-efficient designs by sequentially adding energy design measures (EDMs). Certain EDMs figured prominently in reaching the 50% energy savings goal for both building types:more » (1) reduced lighting power density; (2) optimized area fraction and construction of view glass or skylights, or both, as part of a daylighting system tuned to 46.5 fc (500 lux); (3) reduced infiltration with a main entrance vestibule or an envelope air barrier, or both; and (4) energy recovery ventilators, especially in humid and cold climates. In grocery stores, the most effective EDM, which was chosen for all climates, was replacing baseline medium-temperature refrigerated cases with high-efficiency models that have doors.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
... Production Act of 1993--OpenDaylight Project, Inc. Notice is hereby given that, on November 13, 2013.... 4301 et seq. (``the Act''), OpenDaylight Project, Inc. (``OpenDaylight'') has filed written.... Membership in this group research project remains open, and OpenDaylight intends to file additional written...
An Innovative Enhanced Wall to Reduce the Energy Demand in Buildings
NASA Astrophysics Data System (ADS)
Fantozzi, F.; Filipeschi, S.; Mameli, M.; Nesi, S.; Cillari, G.; Mantelli, M. B. H.; Milanez, F. H.
2017-01-01
Energy saving in buildings is one of most important issues for European countries. Although in the last years many studies have been carried out in order to reach the zero-consumption house the energy rate due to passive solar heating could be further enhanced. This paper proposes a method for increasing the energy rate absorbed by opaque walls by using a two phase loop thermosyphon connecting the internal and the external façade of a prefabricated house wall. The evaporator zone is embedded into the outside facade and the condenser is indoor placed to heat the domestic environment. The thermosyphon has been preliminary designed and implanted into a wall for a prefabricated house in Italy. An original dynamic thermal model of the building equipped with the thermosyphon wall allowed the evolution of the indoor temperature over time and the energy saving rates. The transient behaviour of the building has been simulated during the winter period by using the EnergyPlusTM software. The annual saving on the heating energy is higher than 50% in the case of a low consumption building.
Energy savings opportunities in the global digital television transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Won Young; Gopal, Anand; Phadke, Amol
Globally, terrestrial television (TV) broadcasting is in the midst of a complete transition to digital signals. The last analog terrestrial broadcast is expected to be switched off in the early 2020s. This transition presents huge energy savings opportunities that have thus far been ignored. Digital TV switchovers have likely increased energy consumption as countries have completed transitions by providing digital TV converters to analog TV users, which increase energy consumption and extend the life of energy-inefficient analog TVs. We find that if analog TVs were retired at the time of a digital switchover and replaced with super-efficient flat-panel TVs, suchmore » as light-emitting diode (LED) backlit liquid crystal display (LCD) TVs, there is a combined electricity savings potential of 32 terawatt hours [TWh] per year in countries that have not yet completed their digital TV transition. In view of these findings as well as the dramatic drops of super-efficient TV prices and the unique early-retirement opportunity resulting from cessation of terrestrial analog broadcasts, TV-exchange programs would easily and substantially advance energy efficiency.« less
NASA Astrophysics Data System (ADS)
Lu, Qiheng; Feng, Xiaoyun
2013-03-01
After analyzing the working principle of the four-aspect fixed autoblock system, an energy-saving control model was created based on the dynamics equations of the trains in order to study the energy-saving optimal control strategy of trains in a following operation. Besides the safety and punctuality, the main aims of the model were the energy consumption and the time error. Based on this model, the static and dynamic speed restraints under a four-aspect fixed autoblock system were put forward. The multi-dimension parallel genetic algorithm (GA) and the external punishment function were adopted to solve this problem. By using the real number coding and the strategy of ramps divided into three parts, the convergence of GA was speeded up and the length of chromosomes was shortened. A vector of Gaussian random disturbance with zero mean was superposed to the mutation operator. The simulation result showed that the method could reduce the energy consumption effectively based on safety and punctuality.
Energy savings opportunities in the global digital television transition
Park, Won Young; Gopal, Anand; Phadke, Amol
2016-12-20
Globally, terrestrial television (TV) broadcasting is in the midst of a complete transition to digital signals. The last analog terrestrial broadcast is expected to be switched off in the early 2020s. This transition presents huge energy savings opportunities that have thus far been ignored. Digital TV switchovers have likely increased energy consumption as countries have completed transitions by providing digital TV converters to analog TV users, which increase energy consumption and extend the life of energy-inefficient analog TVs. We find that if analog TVs were retired at the time of a digital switchover and replaced with super-efficient flat-panel TVs, suchmore » as light-emitting diode (LED) backlit liquid crystal display (LCD) TVs, there is a combined electricity savings potential of 32 terawatt hours [TWh] per year in countries that have not yet completed their digital TV transition. In view of these findings as well as the dramatic drops of super-efficient TV prices and the unique early-retirement opportunity resulting from cessation of terrestrial analog broadcasts, TV-exchange programs would easily and substantially advance energy efficiency.« less
David Grant Medical Center energy use baseline and integrated resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, E.E.; Hoshide, R.K.; Dittmer, A.L.
1993-04-01
The US Air Mobility Command (AMC) has tasked Pacific Northwest Laboratory (PNL) with supporting the US Department of Energy (DOE) Federal Energy Management Program`s (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy resource opportunities (EROs) at the David Grant Medical Center (DGMC). This report describes the methodology used to identify and evaluate the EROs at DGMC, provides a life-cycle cost (LCC) analysis for each ERO, and prioritizes any life-cycle cost-effective EROs based on their net present value (NPV), value index (VI), and savings to investment ratio (SIR or ROI). Analysis results are presented for 17 EROsmore » that involve energy use in the areas of lighting, fan and pump motors, boiler operation, infiltration, electric load peak reduction and cogeneration, electric rate structures, and natural gas supply. Typical current energy consumption is approximately 22,900 MWh of electricity (78,300 MBtu), 87,600 kcf of natural gas (90,300 MBtu), and 8,300 gal of fuel oil (1,200 MBtu). A summary of the savings potential by energy-use category of all independent cost-effective EROs is shown in a table. This table includes the first cost, yearly energy consumption savings, and NPV for each energy-use category. The net dollar savings and NPV values as derived by the life-cycle cost analysis are based on the 1992 federal discount rate of 4.6%. The implementation of all EROs could result in a yearly electricity savings of more than 6,000 MWh or 26% of current yearly electricity consumption. More than 15 MW of billable load (total billed by the utility for a 12-month period) or more than 34% of current billed demand could also be saved. Corresponding natural gas savings would be 1,050 kcf (just over 1% of current consumption). Total yearly net energy cost savings for all options would be greater than $343,340. This value does not include any operations and maintenance (O&M) savings.« less
David Grant Medical Center energy use baseline and integrated resource assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, E.E.; Hoshide, R.K.; Dittmer, A.L.
1993-04-01
The US Air Mobility Command (AMC) has tasked Pacific Northwest Laboratory (PNL) with supporting the US Department of Energy (DOE) Federal Energy Management Program's (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy resource opportunities (EROs) at the David Grant Medical Center (DGMC). This report describes the methodology used to identify and evaluate the EROs at DGMC, provides a life-cycle cost (LCC) analysis for each ERO, and prioritizes any life-cycle cost-effective EROs based on their net present value (NPV), value index (VI), and savings to investment ratio (SIR or ROI). Analysis results are presented for 17 EROsmore » that involve energy use in the areas of lighting, fan and pump motors, boiler operation, infiltration, electric load peak reduction and cogeneration, electric rate structures, and natural gas supply. Typical current energy consumption is approximately 22,900 MWh of electricity (78,300 MBtu), 87,600 kcf of natural gas (90,300 MBtu), and 8,300 gal of fuel oil (1,200 MBtu). A summary of the savings potential by energy-use category of all independent cost-effective EROs is shown in a table. This table includes the first cost, yearly energy consumption savings, and NPV for each energy-use category. The net dollar savings and NPV values as derived by the life-cycle cost analysis are based on the 1992 federal discount rate of 4.6%. The implementation of all EROs could result in a yearly electricity savings of more than 6,000 MWh or 26% of current yearly electricity consumption. More than 15 MW of billable load (total billed by the utility for a 12-month period) or more than 34% of current billed demand could also be saved. Corresponding natural gas savings would be 1,050 kcf (just over 1% of current consumption). Total yearly net energy cost savings for all options would be greater than $343,340. This value does not include any operations and maintenance (O M) savings.« less
Stapanian, Martin A.; Kocovsky, Patrick M.; Adams, Jean V.
2009-01-01
1. Non-native mussels have increased water clarity in many lakes and streams in North America and Europe. Diel variation in catchability of some fish species has been linked to visibility during survey trawls (used to measure escapement). 2. Water clarity increased in nearshore areas of western Lake Erie by the early 1990s, following passage of legislation in 1972 to improve water quality (e.g. reduce phosphorus loading) and the invasion of dreissenid mussels (Dreissena spp.) beginning in 1987. 3. We hypothesised that increased water clarity in Lake Erie resulted in decreased catchability of young-of-year (age-0) yellow perch (Perca flavescens Mitchill) during daylight compared to during night. We used a two-tiered modelling approach to test this hypothesis on the ratio (R) of catch per hour (CPH) during night to CPH during daylight in bottom trawl surveys conducted during 1961-2005. 4. First, we examined seven a priori models. The first model, the 'null' model, represented no change in R over time. Three more models tested whether the timing of the change in R was associated with passage of water quality legislation only, dreissenids only (two-period models) and both legislation and dreissenids (three-period models). Three additional models included a 3-year lag before the effects of legislation, dreissenids or both occurred. Secondly, all possible two- and three-period models with a minimum of 2 years per time period were explored a posteriori. The a posteriori procedure determined the temporal transitions to higher R that were best supported by the data, without regard to a priori hypotheses. 5. Night CPH was greater than daylight CPH in 3 of 11 years during 1961-72, in 10 of 15 years during 1973-87, and in 14 of 18 years during 1988-2005. During 1991-2005 night CPH exceeded daylight CPH in all years except one, and night CPH was more than twice daylight CPH in 10 years during this period. 6. The best a priori model had two periods, with a break between 1990 and 1991, corresponding to 3 years after the dreissenid invasion. Similarly, the best two- and three-period a posteriori models both had breaks between 1990 and 1991. The results supported our hypothesis that age-0 yellow perch exhibited a transition to lower catchability during daylight compared to night, and the timing of the transition coincided with the establishment of dreissenid mussels. 7. The most plausible mechanism for our results was increased visibility of the trawl during daylight, resulting in increased avoidance of the trawl. These results have potential applications wherever non-native mussels have increased water clarity.
Investigation of nocturnal oviposition by necrophilous flies in central Texas.
Baldridge, Robert S; Wallace, Susan G; Kirkpatrick, Ryan
2006-01-01
The need to accurately estimate the postmortem interval (PMI) has prompted research into factors affecting fly oviposition (i.e., oviposition and/or larviposition) on a corpse. Research efforts have focused on whether or not diurnally active flies oviposit during nighttime hours. This study reports that nocturnal oviposition (defined as occurring between 2100-0600 h CDST (Central Daylight Savings Time)) did not occur on freshly killed white rats or mice, on beef (fresh or aged up to 48 h), on freshly thawed pigs, nor, usually, on thawed pigs that were aged for up to 48 h. Limited oviposition did occur between 2100 and 2120 h on one bloated pig at a lighted rural site. Necrophilous flies were present and active at lighted and dark sites (urban and rural) before and immediately after sunset, but fly activity on the bait ceased within 50 min postsunset and did not resume until after 0600 h. These observations support other studies reporting that diurnally active flies do not oviposit during the nighttime.
ERIC Educational Resources Information Center
Kosik, Kenneth S.; Heschong, Lisa
An audiotape presents study analysis of the effect of daylighting on student performance. The study includes a focus on skylighting as a way to isolate daylight as an illumination source, and separate illumination effects from other qualities associated with daylighting from windows. Results from test scores of over 21,000 student records, along…
Effects of cardiothoracic physiotherapy on intrapulmonary shunt in abdominal surgical patients.
Ntoumenopoulos, George; Greenwood, Kenneth
1996-01-01
This study investigated the provision of additional evening physiotherapy on pulmonary complications and intrapulmonary shunt (Qs/Qt) after abdominal surgery. Thirty-one elderly patients received either daylight only or daylight plus evening physiotherapy for up to 48 hours. Physiotherapy included combinations of positioning, gravity assisted drainage, breathing exercises, manual techniques, coughing and airway suctioning. Measurements included Qs/Qt and post-operative pulmonary complications. While no significant difference in atelectasis was found, the post-operative Qs/Qt data averaged into six-hour time frames demonstrated significantly lower mean Qs/Qt for the daylight plus evening physiotherapy group between 18 and 24 hours post-surgery. Additional evening physiotherapy may reduce post-operative deterioration in gas exchange after major abdominal surgery.
Reducing Operating Costs and Energy Consumption at Water Utilities
Due to their unique combination of high energy usage and potential for significant savings, utilities are turning to energy-efficient technologies to help save money. Learn about cost and energy saving technologies from this brochure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Sallal, K.A.
1999-07-01
The study aims to explore the effect of different climates on window and skylight design in residential buildings. The study house is evaluated against climates that have design opportunities for passive systems, with emphasis on passive cooling. The study applies a variety of methods to evaluate the design. It has found that earth sheltering and night ventilation have the potential to provide 12--29% and 25--77% of the cooling requirements respectively for the study house in the selected climates. The reduction of the glazing area from 174 ft{sup 2} to 115 ft{sup 2} has different impacts on the cooling energy costmore » in the different climates. In climates such Fresno and Tucson, one should put the cooling energy savings as a priority for window design, particularly when determining the window size. In other climates such as Albuquerque, the priority of window design should be first given to heating savings requirements.« less
A Novel Energy Saving Algorithm with Frame Response Delay Constraint in IEEE 802.16e
NASA Astrophysics Data System (ADS)
Nga, Dinh Thi Thuy; Kim, Mingon; Kang, Minho
Sleep-mode operation of a Mobile Subscriber Station (MSS) in IEEE 802.16e effectively saves energy consumption; however, it induces frame response delay. In this letter, we propose an algorithm to quickly find the optimal value of the final sleep interval in sleep-mode in order to minimize energy consumption with respect to a given frame response delay constraint. The validations of our proposed algorithm through analytical results and simulation results suggest that our algorithm provide a potential guidance to energy saving.
Mission aware energy saving strategies for Army ground vehicles
NASA Astrophysics Data System (ADS)
Dattathreya, Macam S.
Fuel energy is a basic necessity for this planet and the modern technology to perform many activities on earth. On the other hand, quadrupled automotive vehicle usage by the commercial industry and military has increased fuel consumption. Military readiness of Army ground vehicles is very important for a country to protect its people and resources. Fuel energy is a major requirement for Army ground vehicles. According to a report, a department of defense has spent nearly $13.6 billion on fuel and electricity to conduct ground missions. On the contrary, energy availability on this plant is slowly decreasing. Therefore, saving energy in Army ground vehicles is very important. Army ground vehicles are embedded with numerous electronic systems to conduct missions such as silent and normal stationary surveillance missions. Increasing electrical energy consumption of these systems is influencing higher fuel consumption of the vehicle. To save energy, the vehicles can use any of the existing techniques, but they require complex, expensive, and time consuming implementations. Therefore, cheaper and simpler approaches are required. In addition, the solutions have to save energy according to mission needs and also overcome size and weight constraints of the vehicle. Existing research in the current literature do not have any mission aware approaches to save energy. This dissertation research proposes mission aware online energy saving strategies for stationary Army ground vehicles to save energy as well as to meet the electrical needs of the vehicle during surveillance missions. The research also proposes theoretical models of surveillance missions, fuzzy logic models of engine and alternator efficiency data, and fuzzy logic algorithms. Based on these models, two energy saving strategies are proposed for silent and normal surveillance type of missions. During silent mission, the engine is on and batteries power the systems. During normal surveillance mission, the engine is on, gear is on neutral position, the vehicle is stationary, and the alternator powers the systems. The proposed energy saving strategy for silent surveillance mission minimizes unnecessary battery discharges by controlling the power states of systems according to the mission needs and available battery capacity. Initial experiments show that the proposed approach saves 3% energy when compared with the baseline strategy for one scenario and 1.8% for the second scenario. The proposed energy saving strategy for normal surveillance mission operates the engine at fuel-efficient speeds to meet vehicle demand and to save fuel. The experiment and simulation uses a computerized vehicle model and a test bench to validate the approach. In comparison to vehicles with fixed high-idle engine speed increments, experiments show that the proposed strategy saves fuel energy in the range of 0-4.9% for the tested power demand range of 44-69 kW. It is hoped to implement the proposed strategies on a real Army ground vehicle to start realizing the energy savings.
Influence of air temperature on electric consumption in Moscow
NASA Astrophysics Data System (ADS)
Lokoshchenko, Mikhail A.; Nikolayeva, Nataliya A.
2017-04-01
For the first time for mid latitudes and with the use of long-term data of Moscow State University Meteorological observatory a dependence of electric power consumption E on the air temperature T has been studied for each separate day for the period from 1990 to 2015 (totally - 9496 values). As a result, it is shown that the relation is in general decreasing in conditions of cold Moscow region: energy consumption as a rule reduces with a rise of the temperature. However, in time of severe frosts the energy consumption increasing goes to nothing due to special measures for energy savings whereas during heat wave episodes of extremely hot weather (especially in summer of 2010) an opposite tendency appears to the energy consumption increase with the increase of the air temperature due to additional consumption for the air conditioning. This relation between E and T is statistically significant with extremely high confidence probability (more than 0.999). The optimum temperature for the energy saving is 18 ˚C. The air temperature limit values in Moscow during last decades have been discussed. Daily-averaged T varied from -28.0 ˚C in January of 2006 to +31.4 ˚C in August of 2010 so a range of this parameter is almost 60 ˚C. Catastrophic heat wave in 2010 appeared as a secondary summer maximum of the electric consumption annual course. The relation between E and T for separate years demonstrates strong weekly periodicity at the dynamics of E daily values. As a result statistical distribution of E daily values for separate years is bimodal. One its mode is connected with working-days and another one - with non-work days (Saturday, Sunday and holidays) when consumption is much less. In recent time weekly cycle at the electric consumption became weaker due to total fall of industry in Moscow. In recent years the dependence of energy consumption on the air temperature generally became stronger - probably due to changes of its structure (growth of non-industrial users' contribution). A relation of energy consumption with the relative humidity is absent whereas a relation of energy consumption with the water vapor pressure e indirectly reflects a dependence of this parameter on the air temperature. Use of multiple and partial correlation between E, T and e confirmed an absence of direct relation between energy consumption and water vapor pressure. Authors are much grateful to System Operator of Unified Energy System of Russia for given data about electric power consumption in Moscow region.
Brown, Vicki; Ananthapavan, Jaithri; Veerman, Lennert; Sacks, Gary; Lal, Anita; Peeters, Anna; Backholer, Kathryn; Moodie, Marjory
2018-05-15
Television (TV) advertising of food and beverages high in fat, sugar and salt (HFSS) influences food preferences and consumption. Children from lower socioeconomic position (SEP) have higher exposure to TV advertising due to more time spent watching TV. This paper sought to estimate the cost-effectiveness of legislation to restrict HFSS TV advertising until 9:30 pm, and to examine how health benefits and healthcare cost-savings differ by SEP. Cost-effectiveness modelling was undertaken (i) at the population level, and (ii) by area-level SEP. A multi-state multiple-cohort lifetable model was used to estimate obesity-related health outcomes and healthcare cost-savings over the lifetime of the 2010 Australian population. Incremental cost-effectiveness ratios (ICERs) were reported, with assumptions tested through sensitivity analyses. An intervention restricting HFSS TV advertising would cost AUD5.9M (95% UI AUD5.8M⁻AUD7M), resulting in modelled reductions in energy intake (mean 115 kJ/day) and body mass index (BMI) (mean 0.352 kg/m²). The intervention is likely to be cost-saving, with 1.4 times higher total cost-savings and 1.5 times higher health benefits in the most disadvantaged socioeconomic group (17,512 HALYs saved (95% UI 10,372⁻25,155); total cost-savings AUD126.3M (95% UI AUD58.7M⁻196.9M) over the lifetime) compared to the least disadvantaged socioeconomic group (11,321 HALYs saved (95% UI 6812⁻15,679); total cost-savings AUD90.9M (95% UI AUD44.3M⁻136.3M)). Legislation to restrict HFSS TV advertising is likely to be cost-effective, with greater health benefits and healthcare cost-savings for children with low SEP.
Veerman, Lennert; Lal, Anita; Peeters, Anna; Backholer, Kathryn; Moodie, Marjory
2018-01-01
Television (TV) advertising of food and beverages high in fat, sugar and salt (HFSS) influences food preferences and consumption. Children from lower socioeconomic position (SEP) have higher exposure to TV advertising due to more time spent watching TV. This paper sought to estimate the cost-effectiveness of legislation to restrict HFSS TV advertising until 9:30 pm, and to examine how health benefits and healthcare cost-savings differ by SEP. Cost-effectiveness modelling was undertaken (i) at the population level, and (ii) by area-level SEP. A multi-state multiple-cohort lifetable model was used to estimate obesity-related health outcomes and healthcare cost-savings over the lifetime of the 2010 Australian population. Incremental cost-effectiveness ratios (ICERs) were reported, with assumptions tested through sensitivity analyses. An intervention restricting HFSS TV advertising would cost AUD5.9M (95% UI AUD5.8M–AUD7M), resulting in modelled reductions in energy intake (mean 115 kJ/day) and body mass index (BMI) (mean 0.352 kg/m2). The intervention is likely to be cost-saving, with 1.4 times higher total cost-savings and 1.5 times higher health benefits in the most disadvantaged socioeconomic group (17,512 HALYs saved (95% UI 10,372–25,155); total cost-savings AUD126.3M (95% UI AUD58.7M–196.9M) over the lifetime) compared to the least disadvantaged socioeconomic group (11,321 HALYs saved (95% UI 6812–15,679); total cost-savings AUD90.9M (95% UI AUD44.3M–136.3M)). Legislation to restrict HFSS TV advertising is likely to be cost-effective, with greater health benefits and healthcare cost-savings for children with low SEP. PMID:29762517
Goodwin accelerator model revisited with fixed time delays
NASA Astrophysics Data System (ADS)
Matsumoto, Akio; Merlone, Ugo; Szidarovszky, Ferenc
2018-05-01
Dynamics of Goodwin's accelerator business cycle model is reconsidered. The model is characterized by a nonlinear accelerator and an investment time delay. The role of the nonlinearity for the birth of persistent oscillations is fully discussed in the existing literature. On the other hand, not much of the role of the delay has yet been revealed. The purpose of this paper is to show that the delay really matters. In the original framework of Goodwin [6], it is first demonstrated that there is a threshold value of the delay: limit cycles arise for smaller values than the threshold and so do sawtooth oscillations for larger values. In the extended framework in which a consumption or saving delay, in addition to the investment delay, is introduced, three main results are demonstrated under assumption of the identical length of investment and consumption delays. The dynamics with consumption delay is basically the same as that of the single delay model. Second, in the case of saving delay, the steady state can coexist with the stable and unstable limit cycles in the stable case. Third, in the unstable case, there is an interval of delay in which the limit cycle or the sawtooth oscillation emerges depending on the choice of the constant initial function.
Energy-saving method for technogenic waste processing
Dikhanbaev, Bayandy; Dikhanbaev, Aristan Bayandievich
2017-01-01
Dumps of a mining-metallurgical complex of post-Soviet Republics have accumulated a huge amount of technogenic waste products. Out of them, Kazakhstan alone has preserved about 20 billion tons. In the field of technogenic waste treatment, there is still no technical solution that leads it to be a profitable process. Recent global trends prompted scientists to focus on developing energy-saving and a highly efficient melting unit that can significantly reduce specific fuel consumption. This paper reports, the development of a new technological method—smelt layer of inversion phase. The introducing method is characterized by a combination of ideal stirring and ideal displacement regimes. Using the method of affine modelling, recalculation of pilot plant’s test results on industrial sample has been obtained. Experiments show that in comparison with bubbling and boiling layers of smelt, the degree of zinc recovery increases in the layer of inversion phase. That indicates the reduction of the possibility of new formation of zinc silicates and ferrites from recombined molecules of ZnO, SiO2, and Fe2O3. Calculations show that in industrial samples of the pilot plant, the consumption of natural gas has reduced approximately by two times in comparison with fuming-furnace. The specific fuel consumption has reduced by approximately four times in comparison with Waelz-kiln. PMID:29281646
Performance of a novel multiple-signal luminescence sediment tracing method
NASA Astrophysics Data System (ADS)
Reimann, Tony
2014-05-01
Optically Stimulated Luminescence (OSL) is commonly used for dating sediments. Luminescence signals build up due to exposure of mineral grains to natural ionizing radiation, and are reset when these grains are exposed to (sun)light during sediment transport and deposition. Generally, luminescence signals can be read in two ways, potentially providing information on the burial history (dating) or the transport history (sediment tracing) of mineral grains. In this study we use a novel luminescence measurement procedure (Reimann et al., submitted) that simultaneously monitors six different luminescence signals from the same sub-sample (aliquot) to infer the transport history of sand grains. Daylight exposure experiments reveal that each of these six signals resets (bleaches) at a different rate, thus allowing to trace the bleaching history of the sediment in six different observation windows. To test the feasibility of luminescence sediment tracing in shallow-marine coastal settings we took eight sediment samples from the pilot mega-nourishment Zandmotor in Kijkduin (South-Holland). This site provides relatively controlled conditions as the morphological evolution of this nourishment is densely monitored (Stive et al., 2013). After sampling the original nourishment source we took samples along the seaward facing contour of the spit that was formed from August 2011 (start of nourishment) to June 2012 (sampling). It is presumed that these samples originate from the source and were transported and deposited within the first year after construction. The measured luminescence of a sediment sample was interpolated onto the daylight bleaching curve of each signal to assign the Equivalent Exposure Time (EET) to a sample. The EET is a quantitative measure of the full daylight equivalent a sample was exposed to during sediment transport, i.e. the higher the EET the longer the sample has been transported or the more efficient it has been exposed to day-light during sediment transport. The EET increases with increasing distance from the nourishment source, indicating that our method is capable to quantify sediment transport distances. We furthermore observed that the EET of an aeolian analogue is orders of magnitudes higher than those of the water-lain transported Zandmotor samples, suggesting that our approach is also able to differentiate between different modes of coastal sediment transport. This new luminescence approach offers new possibilities to decipher the sedimentation history of palaeo-environmental archives e.g. in coastal, fluvial or aeolian settings. References: Reimann, T.et al. Quantifying the degreeof bleaching during sediment transport using a polymineral multiple-signalluminescence approach. Submitted. Stive, M.J.F. et al. 2013. A New Alternative to Saving Our Beaches from Sea-Level Rise: The SandEngine. Journal of Coastal research 29, 1001-1008.
Elizabeth A. Flaherty; Merav Ben-David; Winston P. Smith
2010-01-01
Gliding allows mammals to exploit canopy habitats of old-growth forests possibly as a means to save energy. To assess costs of quadrupedal locomotion for a gliding arboreal mammal, we used open-flow respirometry and a variable-speed treadmill to measure oxygen consumption and to calculate cost of transport, excess exercise oxygen consumption, and excess post-exercise...
Aging influence on sensing properties of porous silica films sensitized toward ammonia
NASA Astrophysics Data System (ADS)
Tyszkiewicz, Cuma; Rogoziński, Roman
2015-12-01
The sol-gel technology allows preparation of thin silica films ranging in porosity from dense to highly porous. These films can function as a matrix binding molecules of the pH-sensitive dyes and can be utilized as the sensitive films for intensity based planar evanescent wave chemical sensors. Sensitive properties of these dyes decreases in time due to aging processes. We report characterization of weakening of sensing properties of highly porous silica films doped with the bromocresole purple (BCP). In the presence of the gaseous ammonia, the absorption band (AB) of protonated BCP centered at λ=430 nm, is shifted toward λ=591 nm due to deprotonation, resulting in the increase of sensitive films absorption in the range of wavelengths of shifted AB. Two sets of films were investigated. Films from the first one were cyclically exposed to the ammonia and stored isolated from the daylight. Films from the second set weren't exposed to the ammonia and were stored in a staining jar exposed to the daylight. A depth of the AB at λ=430 nm was measured using a spectrophotometer. A sensitivity of the films toward ammonia was measured using LED emitting at center wavelength λ=610 nm. As was shown, the sensitivity of these films exposed to the ammonia diluted in dry air, and isolated from the daylight, decreases in time exponentially. The magnitude of that decrease monotonically depends on the ammonia concentration. It was also shown that the daylight causes quick aging of films not exposed to the ammonia. A depth of the AB centered at λ=430 nm relatively quickly decreased when compared with films isolated from the daylight and exposed to the ammonia.
Energy Smart Schools--Applied Research, Field Testing, and Technology Integration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nebiat Solomon; Robin Vieira; William L. Manz
2004-12-01
The National Association of State Energy Officials (NASEO) in conjunction with the California Energy Commission, the Energy Center of Wisconsin, the Florida Solar Energy Center, the New York State Energy Research and Development Authority, and the Ohio Department of Development's Office of Energy Efficiency conducted a four-year, cost-share project with the U.S. Department of Energy (USDOE), Office of Energy Efficiency and Renewable Energy to focus on energy efficiency and high-performance technologies in our nation's schools. NASEO was the program lead for the MOU-State Schools Working group, established in conjunction with the USDOE Memorandum of Understanding process for collaboration among statemore » and federal energy research and demonstration offices and organizations. The MOU-State Schools Working Group included State Energy Offices and other state energy research organizations from all regions of the country. Through surveys and analyses, the Working Group determined the school-related energy priorities of the states and established a set of tasks to be accomplished, including the installation and evaluation of microturbines, advanced daylighting research, testing of schools and classrooms, and integrated school building technologies. The Energy Smart Schools project resulted in the adoption of advanced energy efficiency technologies in both the renovation of existing schools and building of new ones; the education of school administrators, architects, engineers, and manufacturers nationwide about the energy-saving, economic, and environmental benefits of energy efficiency technologies; and improved the learning environment for the nation's students through use of better temperature controls, improvements in air quality, and increased daylighting in classrooms. It also provided an opportunity for states to share and replicate successful projects to increase their energy efficiency while at the same time driving down their energy costs.« less
NASA Glenn Research Center Experience Using DOE Midwest Region Super ESPC
NASA Technical Reports Server (NTRS)
Zala, Laszlo F.
2000-01-01
The energy crisis of 1973 prompted the Federal Government and private industry to look into alternative methods to save energy. At the same time the constant reduction of operations and maintenance funds during the last 5 years forced Glenn Research Center (GRC) to look for alternative funding sources to meet the mandate to reduce energy consumption. The Super Energy Savings Performance Contract (ESPC) was chosen as a viable source of facility improvement funding that can create larger project scope and help replace aging, inefficient equipment. This paper describes Glenn's participation in the Department of Energy (DOE) Super ESPC program. This program provided Glenn cost savings in the performance of energy audits, preparation of documents, evaluation of proposals, and selection of energy service company (ESCO).
ERIC Educational Resources Information Center
Harrigan, Merrilee
1999-01-01
The nonprofit Alliance to Save Energy has been helping schools reduce energy consumption through a combination of retrofits, classroom instruction, and behavior. Lists eight small steps to big energy savings, among them: involve the whole school, stop leaks, turn off computers, and recycle. (MLF)
A hydrogen transient nuclear magnetic resonance sensor for industrial drying applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicholls, C.
1990-01-01
It has been estimated that industrial non-paper drying processes consume {approximately}0.8 quad (i.e. 8 {times} 10{sup 14} BTU) of energy per year in the United States, representing {approximately}5% of total industrial consumption. If improved technologies could be used to increase the efficiencies of the drying process and hence produce a 2% reduction in energy consumption, the energy savings would be 0.016 quad per year, or {approximately}2.5 million bbl of crude oil. DOE studies indicated that the most attractive R D target to aid in achieving these savings was an advanced moisture sensor, capable of application to a wide variety ofmore » drying processes. To meet these objectives the sensor should accurately monitor product moisture content over the range 2--35 % wt moisture (wb) and be usable at temperatures up to 350{degree}F. 22 refs., 11 figs., 1 tab.« less
Treatment of emulsified oils by electrocoagulation: pulsed voltage applications.
Genc, Ayten; Bakirci, Busra
2015-01-01
The effect of pulsed voltage application on energy consumption during electrocoagulation was investigated. Three voltage profiles having the same arithmetic average with respect to time were applied to the electrodes. The specific energy consumption for these profiles were evaluated and analyzed together with oil removal efficiencies. The effects of applied voltages, electrode materials, electrode configurations, and pH on oil removal efficiency were determined. Electrocoagulation experiments were performed by using synthetic and real wastewater samples. The pulsed voltages saved energy during the electrocoagulation process. In continuous operation, energy saving was as high as 48%. Aluminum electrodes used for the treatment of emulsified oils resulted in higher oil removal efficiencies in comparison with stainless steel and iron electrodes. When the electrodes gap was less than 1 cm, higher oil removal efficiencies were obtained. The highest oil removal efficiencies were 95% and 35% for the batch and continuous operating modes, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sintov, Nicole; Dux, Ellen; Tran, Agassi
Here, the aim of our study was to evaluate the impact of a competition-based intervention combining high resolution electricity feedback, incentives, information, and prompts on college dormitory residents’ energy consumption and participation in demand response (DR) events. We also investigated changes in individual-level pro-environmental behaviors and examined psycho-social correlates of behavior change. Residents of 39 suites in a freshman residence hall competed against one another to reduce energy consumption and win prizes as part of a 3-week competition. Feedback was provided in near real time at the suite-level via an interactive touch-screen kiosk. Participants also completed baseline and followup surveys.more » Findings have indicated that electricity use among all suites was approximately 6.4% lower during the competition period compared to baseline, a significant reduction. Additionally, participants reported engaging in various pro-environmental behaviors significantly more frequently during the competition relative to baseline. Changes in pro-environmental behavior were associated with changes in level of group identification and perceived social norms. In three weeks, dormitory residents saved 3, 158 kWh of electricity compared to baseline – the equivalent of more than 3, 470 pounds of carbon dioxide emissions. Our findings provide evidence that real-time feedback, combined with incentives, information, and prompts, can motivate on-campus residents to reduce energy consumption. We contribute to a limited body of evidence supporting the effectiveness of dorm energy competitions in motivating college students to save energy. In addition, we identified individual-level behavioral and psycho-social changes made during such an intervention. University residential life planners may also use the results of this research to inform student programming.« less
Sintov, Nicole; Dux, Ellen; Tran, Agassi; ...
2016-07-04
Here, the aim of our study was to evaluate the impact of a competition-based intervention combining high resolution electricity feedback, incentives, information, and prompts on college dormitory residents’ energy consumption and participation in demand response (DR) events. We also investigated changes in individual-level pro-environmental behaviors and examined psycho-social correlates of behavior change. Residents of 39 suites in a freshman residence hall competed against one another to reduce energy consumption and win prizes as part of a 3-week competition. Feedback was provided in near real time at the suite-level via an interactive touch-screen kiosk. Participants also completed baseline and followup surveys.more » Findings have indicated that electricity use among all suites was approximately 6.4% lower during the competition period compared to baseline, a significant reduction. Additionally, participants reported engaging in various pro-environmental behaviors significantly more frequently during the competition relative to baseline. Changes in pro-environmental behavior were associated with changes in level of group identification and perceived social norms. In three weeks, dormitory residents saved 3, 158 kWh of electricity compared to baseline – the equivalent of more than 3, 470 pounds of carbon dioxide emissions. Our findings provide evidence that real-time feedback, combined with incentives, information, and prompts, can motivate on-campus residents to reduce energy consumption. We contribute to a limited body of evidence supporting the effectiveness of dorm energy competitions in motivating college students to save energy. In addition, we identified individual-level behavioral and psycho-social changes made during such an intervention. University residential life planners may also use the results of this research to inform student programming.« less
Field testing energy-saving hermetic compressors in residential refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauber, R.S.; Middleton, M.G.
The design of an energy-saving compressor for low back pressure applications is reviewed. Calorimeter performance results are stated for two sizes of the efficient design and compared with performance test results for a standard compressor. Power consumption of a refrigerator-freezer is given with a standard compressor and with the energy-saving compressor. The preparation of the refrigerators used in the field test is discussed, along with the criteria used in selecting the instrumentation for the project. Results of the energy-saving compressor in the field test, along with a comparison to a standard production compressor, are presented. Some conclusions are drawn, basedmore » on the data, in relation to important factors in residential refrigerator power consumption.« less
Field testing energy-saving hermetic compressors in residential refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauber, R.S.; Middleton, M.G.
The design of an energy saving compressor for low back pressure applications is reviewed. Calorimeter performance results are stated for two sizes of the efficient design and compared with performance test results for a standard compressor. Power consumption of a refrigerator-freezer is given with a standard compressor and with the energy saving compressor. The preparation of the refrigerators used in the field test are discussed along with the criteria used in selecting the instrumentation for the project. Results of the energy saving compressor in the field test along with a comparison to a standard production compressor are presented. Some conclusionsmore » are drawn, based on the data, in relation to important factors in residential refrigerator power consumption.« less
To Save or to Consume: Linking Growth Theory with the Keynesian Model
ERIC Educational Resources Information Center
Kwok, Yun-kwong
2007-01-01
In the neoclassical growth theory, higher saving rate gives rise to higher output per capita. However, in the Keynesian model, higher saving rate causes lower consumption, which may lead to a recession. Students may ask, "Should we save or should we consume?" In most of the macroeconomics textbooks, economic growth and Keynesian economics are in…
Daylighting in Schools: Improving Student Performance and Health at a Price Schools Can Afford.
ERIC Educational Resources Information Center
Plympton, Patricia; Conway, Susan; Epstein, Kyra
This document discusses evidence regarding daylighting and student performance and development, and presents four case studies of schools that have cost effectively implemented daylighting into their buildings. Case studies reveal that design and construction strategies that incorporate daylighting do not significantly increase costs over…
ERIC Educational Resources Information Center
Kennedy, Mike
2010-01-01
When the subject of buildings and daylighting arises, most people's thoughts will turn first to windows. To the uninitiated, it seems a simple formula: more windows, more daylight; fewer windows, less daylight. But designers know that effective use of daylighting in a building design involves more than just letting in light to otherwise darkened…
Theoretical solution for light transmission of a bended hollow light guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kocifaj, Miroslav; Darula, Stanislav; Kittler, Richard
2010-08-15
Hollow light guides with very high reflective inner surfaces are novel daylight systems that collect sunlight and skylight available on the roof of buildings transporting it into deep or windowless interiors in building cores. Thus the better utilization of daylight can result in energy savings and wellbeing in these enclosed indoor spaces. An analytical complex solution of a straight tube system was solved in the HOLIGILM method with a user-friendly tool available on the http://www.holigilm.info. An even more difficult light flow transport is to be determined in bended tubes usually placed on sloped roofs where a bend is necessary tomore » adjust the vertical pass through the ceilings. This paper presents the theoretical derivation of the model with its graphical representation and coordinate system respecting backward ray-tracing bend distortions. To imagine the resulting illuminance on the horizontal plane element in the interior, the virtual ray (i.e. luminance in an elementary solid angle) has to pass the ceiling diffuser interface, the inner mirror like tube with a bend, through a roof cupola attachment to the element of the sky and sun light source. Due to this complexity and the lengthy derivation and explanations more practical applications will be published later in a separate contribution. (author)« less
Energy-Efficient ZigBee-Based Wireless Sensor Network for Track Bicycle Performance Monitoring
Gharghan, Sadik K.; Nordin, Rosdiadee; Ismail, Mahamod
2014-01-01
In a wireless sensor network (WSN), saving power is a vital requirement. In this paper, a simple point-to-point bike WSN was considered. The data of bike parameters, speed and cadence, were monitored and transmitted via a wireless communication based on the ZigBee protocol. Since the bike parameters are monitored and transmitted on every bike wheel rotation, this means the sensor node does not sleep for a long time, causing power consumption to rise. Therefore, a newly proposed algorithm, known as the Redundancy and Converged Data (RCD) algorithm, was implemented for this application to put the sensor node into sleep mode while maintaining the performance measurements. This is achieved by minimizing the data packets transmitted as much as possible and fusing the data of speed and cadence by utilizing the correlation measurements between them to minimize the number of sensor nodes in the network to one node, which results in reduced power consumption, cost, and size, in addition to simpler hardware implementation. Execution of the proposed RCD algorithm shows that this approach can reduce the current consumption to 1.69 mA, and save 95% of the sensor node energy. Also, the comparison results with different wireless standard technologies demonstrate minimal current consumption in the sensor node. PMID:25153141
Energy-efficient ZigBee-based wireless sensor network for track bicycle performance monitoring.
Gharghan, Sadik K; Nordin, Rosdiadee; Ismail, Mahamod
2014-08-22
In a wireless sensor network (WSN), saving power is a vital requirement. In this paper, a simple point-to-point bike WSN was considered. The data of bike parameters, speed and cadence, were monitored and transmitted via a wireless communication based on the ZigBee protocol. Since the bike parameters are monitored and transmitted on every bike wheel rotation, this means the sensor node does not sleep for a long time, causing power consumption to rise. Therefore, a newly proposed algorithm, known as the Redundancy and Converged Data (RCD) algorithm, was implemented for this application to put the sensor node into sleep mode while maintaining the performance measurements. This is achieved by minimizing the data packets transmitted as much as possible and fusing the data of speed and cadence by utilizing the correlation measurements between them to minimize the number of sensor nodes in the network to one node, which results in reduced power consumption, cost, and size, in addition to simpler hardware implementation. Execution of the proposed RCD algorithm shows that this approach can reduce the current consumption to 1.69 mA, and save 95% of the sensor node energy. Also, the comparison results with different wireless standard technologies demonstrate minimal current consumption in the sensor node.
Energy efficiency buildings program
NASA Astrophysics Data System (ADS)
1981-05-01
Progress is reported in developing techniques for auditing the energy performance of buildings. The ventilation of buildings and indoor air quality is discussed from the viewpoint of (1) combustion generated pollutants; (2) organic contaminants; (3) radon emanation, measurements, and control; (4) strategies for the field monitoring of indoor air quality; and (5) mechanical ventilation systems using air-to-air heat exchanges. The development of energy efficient windows to provide optimum daylight with minimal thermal losses in cold weather and minimum thermal gain in hot weather is considered as well as the production of high frequency solid state ballasts for fluorescent lights to provide more efficient lighting at a 25% savings over conventional core ballasts. Data compilation, analysis, and demonstration activities are summarized.
Optical characterization of fritted glass for architectural applications
NASA Astrophysics Data System (ADS)
Jonsson, Jacob C.; Rubin, Michael D.; Nilsson, Annica M.; Jonsson, Andreas; Roos, Arne
2009-04-01
Fritted glass is commonly used as a light diffusing element in modern buildings. Traditionally it has been used for aesthetic purposes but it can also be used for energy savings by incorporating it in novel daylighting systems? To answer such questions the light scattering properties must be properly characterized. This paper contains measurements of different varieties of fritted glass, ranging from the simplest direct-hemispherical measurements to angle-resolved goniometer measurements. Modeling the light scattering to obtain the full bidirectional scattering distribution function (BSDF) extends the measured data, making it useful in simulation programs such as Window 6 and Radiance. Surface profilometry results and SEM micrographs are included to demonstrate the surface properties of the samples studied.
Public perceptions of energy consumption and savings
Attari, Shahzeen Z.; DeKay, Michael L.; Davidson, Cliff I.; Bruine de Bruin, Wändi
2010-01-01
In a national online survey, 505 participants reported their perceptions of energy consumption and savings for a variety of household, transportation, and recycling activities. When asked for the most effective strategy they could implement to conserve energy, most participants mentioned curtailment (e.g., turning off lights, driving less) rather than efficiency improvements (e.g., installing more efficient light bulbs and appliances), in contrast to experts’ recommendations. For a sample of 15 activities, participants underestimated energy use and savings by a factor of 2.8 on average, with small overestimates for low-energy activities and large underestimates for high-energy activities. Additional estimation and ranking tasks also yielded relatively flat functions for perceived energy use and savings. Across several tasks, participants with higher numeracy scores and stronger proenvironmental attitudes had more accurate perceptions. The serious deficiencies highlighted by these results suggest that well-designed efforts to improve the public's understanding of energy use and savings could pay large dividends. PMID:20713724
An improved cellular automata model for train operation simulation with dynamic acceleration
NASA Astrophysics Data System (ADS)
Li, Wen-Jun; Nie, Lei
2018-03-01
Urban rail transit plays an important role in the urban public traffic because of its advantages of fast speed, large transport capacity, high safety, reliability and low pollution. This study proposes an improved cellular automaton (CA) model by considering the dynamic characteristic of the train acceleration to analyze the energy consumption and train running time. Constructing an effective model for calculating energy consumption to aid train operation improvement is the basis for studying and analyzing energy-saving measures for urban rail transit system operation.
NASA Astrophysics Data System (ADS)
Baek, Sangkyu; Choi, Bong Dae
We investigate power consumption of a mobile station with the power saving class of type 1 in the IEEE 802.16e. We deal with stochastic behavior of mobile station during not only sleep mode period but also awake mode period with both downlink and uplink traffics. Our methods for investigating the power saving class of type 1 are to construct the embedded Markov chain and the semi-Markov chain generated by the embedded Markov chain. To see the effect of the sleep mode, we obtain the average power consumption of a mobile station and the mean queueing delay of a message. Numerical results show that the larger size of the sleep window makes the power consumption of a mobile station smaller and the queueing delay of a downlink message longer.
Heat-electrical regeneration way to intensive energy saving in an electric arc furnaces
NASA Astrophysics Data System (ADS)
Kartavtcev, S.; Matveev, S.; Neshporenko, E.
2018-03-01
Energy saving in steel production is of great significance for its large economical scale of 1500 mil t/year and high-energy consumption. Steady trend of last years is an increase of steel production in electric arc furnaces (EAF) with a very high consumption of electricity up to 750 kWh/ton. The intention to reduce so much energy consumption they can reach by many ways. One of such way is a transforming heat energy of liquid steel to electricity and destine it to steel electric arc process. Under certain conditions, it may lead to “zero” consumption of electric power in the process. The development of these conditions leads to the formation of energy-efficient heat schemes, with a minimum electricity consumption from the external network.
Qi, Xuewei; Wu, Guoyuan; Boriboonsomsin, Kanok; ...
2016-01-01
Plug-in hybrid electric vehicles (PHEVs) show great promise in reducing transportation-related fossil fuel consumption and greenhouse gas emissions. Designing an efficient energy management system (EMS) for PHEVs to achieve better fuel economy has been an active research topic for decades. Most of the advanced systems rely either on a priori knowledge of future driving conditions to achieve the optimal but not real-time solution (e.g., using a dynamic programming strategy) or on only current driving situations to achieve a real-time but nonoptimal solution (e.g., rule-based strategy). This paper proposes a reinforcement learning–based real-time EMS for PHEVs to address the trade-off betweenmore » real-time performance and optimal energy savings. The proposed model can optimize the power-split control in real time while learning the optimal decisions from historical driving cycles. Here, a case study on a real-world commute trip shows that about a 12% fuel saving can be achieved without considering charging opportunities; further, an 8% fuel saving can be achieved when charging opportunities are considered, compared with the standard binary mode control strategy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, Xuewei; Wu, Guoyuan; Boriboonsomsin, Kanok
Plug-in hybrid electric vehicles (PHEVs) show great promise in reducing transportation-related fossil fuel consumption and greenhouse gas emissions. Designing an efficient energy management system (EMS) for PHEVs to achieve better fuel economy has been an active research topic for decades. Most of the advanced systems rely either on a priori knowledge of future driving conditions to achieve the optimal but not real-time solution (e.g., using a dynamic programming strategy) or on only current driving situations to achieve a real-time but nonoptimal solution (e.g., rule-based strategy). This paper proposes a reinforcement learning–based real-time EMS for PHEVs to address the trade-off betweenmore » real-time performance and optimal energy savings. The proposed model can optimize the power-split control in real time while learning the optimal decisions from historical driving cycles. Here, a case study on a real-world commute trip shows that about a 12% fuel saving can be achieved without considering charging opportunities; further, an 8% fuel saving can be achieved when charging opportunities are considered, compared with the standard binary mode control strategy.« less
Acceleration of Radiance for Lighting Simulation by Using Parallel Computing with OpenCL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Wangda; McNeil, Andrew; Wetter, Michael
2011-09-06
We report on the acceleration of annual daylighting simulations for fenestration systems in the Radiance ray-tracing program. The algorithm was optimized to reduce both the redundant data input/output operations and the floating-point operations. To further accelerate the simulation speed, the calculation for matrix multiplications was implemented using parallel computing on a graphics processing unit. We used OpenCL, which is a cross-platform parallel programming language. Numerical experiments show that the combination of the above measures can speed up the annual daylighting simulations 101.7 times or 28.6 times when the sky vector has 146 or 2306 elements, respectively.
MODIS Measures Fraction of Sunlight Absorbed by Plants
NASA Technical Reports Server (NTRS)
2002-01-01
At the height of the solar cycle, the Sun is finally displaying some fireworks. This image from the Solar and Heliospheric Observatory (SOHO) shows a large solar flare from June 6, 2000 at 1424 Universal Time (10:24 AM Eastern Daylight Savings Time). Associated with the flare was a coronal mass ejection that sent a wave of fast moving charged particles straight towards Earth. (The image was acquired by the Extreme ultaviolet Imaging Telescope (EIT), one of 12 instruments aboard SOHO) Solar activity affects the Earth in several ways. The particles generated by flares can disrupt satellite communications and interfere with power transmission on the Earth's surface. Earth's climate is tied to the total energy emitted by the sun, cooling when the sun radiates less energy and warming when solar output increases. Solar radiation also produces ozone in the stratosphere, so total ozone levels tend to increase during the solar maximum. For more information about these solar flares and the SOHO mission, see NASA Science News or the SOHO home page. For more about the links between the sun and climate change, see Sunspots and the Solar Max. Image courtesy SOHO Extreme ultaviolet Imaging Telescope, ESA/NASA
NASA Technical Reports Server (NTRS)
2002-01-01
At the height of the solar cycle, the Sun is finally displaying some fireworks. This image from the Solar and Heliospheric Observatory (SOHO) shows a large solar flare from June 6, 2000 at 1424 Universal Time (10:24 AM Eastern Daylight Savings Time). Associated with the flare was a coronal mass ejection that sent a wave of fast moving charged particles straight towards Earth. (The image was acquired by the Extreme ultaviolet Imaging Telescope (EIT), one of 12 instruments aboard SOHO) Solar activity affects the Earth in several ways. The particles generated by flares can disrupt satellite communications and interfere with power transmission on the Earth's surface. Earth's climate is tied to the total energy emitted by the sun, cooling when the sun radiates less energy and warming when solar output increases. Solar radiation also produces ozone in the stratosphere, so total ozone levels tend to increase during the solar maximum. For more information about these solar flares and the SOHO mission, see NASA Science News or the SOHO home page. For more about the links between the sun and climate change, see Sunspots and the Solar Max. Image courtesy SOHO Extreme ultaviolet Imaging Telescope, ESA/NASA
EVALUATION OF A PROCEDURE FOR USING DAYLIGHT PROJECTION OF FILM LOOPS IN TEACHING SKILLS.
ERIC Educational Resources Information Center
HARBY, S.F.
EQUIPMENT USING A TRANSLUCENT SCREEN AND REAR PROJECTION HAS MADE IT POSSIBLE TO PROJECT MOTION PICTURES IN DAYLIGHT (DAYLIGHT PROJECTION). FILMS CAN BE SHOWN REPEATEDLY WHEN FORMED INTO A FILM LOOP (CONTINUOUS LOOP PROJECTION). DAYLIGHT PROJECTION AND CONTINUOUS LOOP PROJECTION WERE USED TO INVESTIGATE THE FOLLOWING QUESTIONS--(1) ARE FILM LOOP…
Are we indeed what we eat? Street food consumption in the Market Circle area of Takoradi, Ghana.
Hiamey, Stephen Edem; Amuquandoh, Francis Eric; Boison, Grace Aba
2013-01-01
The paper examines street foods consumption in the Market Circle of Sekondi-Takoradi, Ghana. The data used for the study were obtained from individuals who were either purchasing or consuming street foods in the Market Circle in August of 2011. The results revealed that the average consumer makes use of street foods six times in a week and there was a penchant for carbohydrate based foods over other types of street foods. Reasons including cost saving, convenience and eating on credit were noted to underlie the consumption of street foods in the area. Based on the findings, it was concluded that the high consumption of street foods in the Market Circle was for reasons other than nutrition and health. © The Author(s) 2015.
Energy-Efficient Scheduling for Hybrid Tasks in Control Devices for the Internet of Things
Gao, Zhigang; Wu, Yifan; Dai, Guojun; Xia, Haixia
2012-01-01
In control devices for the Internet of Things (IoT), energy is one of the critical restriction factors. Dynamic voltage scaling (DVS) has been proved to be an effective method for reducing the energy consumption of processors. This paper proposes an energy-efficient scheduling algorithm for IoT control devices with hard real-time control tasks (HRCTs) and soft real-time tasks (SRTs). The main contribution of this paper includes two parts. First, it builds the Hybrid tasks with multi-subtasks of different function Weight (HoW) task model for IoT control devices. HoW describes the structure of HRCTs and SRTs, and their properties, e.g., deadlines, execution time, preemption properties, and energy-saving goals, etc. Second, it presents the Hybrid Tasks' Dynamic Voltage Scaling (HTDVS) algorithm. HTDVS first sets the slowdown factors of subtasks while meeting the different real-time requirements of HRCTs and SRTs, and then dynamically reclaims, reserves, and reuses the slack time of the subtasks to meet their ideal energy-saving goals. Experimental results show HTDVS can reduce energy consumption about 10%–80% while meeting the real-time requirements of HRCTs, HRCTs help to reduce the deadline miss ratio (DMR) of systems, and HTDVS has comparable performance with the greedy algorithm and is more favorable to keep the subtasks' ideal speeds. PMID:23112659
Saving Money Through Energy Conservation.
ERIC Educational Resources Information Center
Presley, Michael H.; And Others
This publication is an introduction to personal energy conservation. The first chapter presents a rationale for conserving energy and points out that private citizens control about one third of this country's energy consumption. Chapters two and three show how to save money by saving energy. Chapter two discusses energy conservation methods in the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darghouth, Naim; Barbose, Galen; Wiser, Ryan
2010-03-30
Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods aremore » under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.« less
Joint optimization of green vehicle scheduling and routing problem with time-varying speeds
Zhang, Dezhi; Wang, Xin; Ni, Nan; Zhang, Zhuo
2018-01-01
Based on an analysis of the congestion effect and changes in the speed of vehicle flow during morning and evening peaks in a large- or medium-sized city, the piecewise function is used to capture the rules of the time-varying speed of vehicles, which are very important in modelling their fuel consumption and CO2 emission. A joint optimization model of the green vehicle scheduling and routing problem with time-varying speeds is presented in this study. Extra wages during nonworking periods and soft time-window constraints are considered. A heuristic algorithm based on the adaptive large neighborhood search algorithm is also presented. Finally, a numerical simulation example is provided to illustrate the optimization model and its algorithm. Results show that, (1) the shortest route is not necessarily the route that consumes the least energy, (2) the departure time influences the vehicle fuel consumption and CO2 emissions and the optimal departure time saves on fuel consumption and reduces CO2 emissions by up to 5.4%, and (3) extra driver wages have significant effects on routing and departure time slot decisions. PMID:29466370
Joint optimization of green vehicle scheduling and routing problem with time-varying speeds.
Zhang, Dezhi; Wang, Xin; Li, Shuangyan; Ni, Nan; Zhang, Zhuo
2018-01-01
Based on an analysis of the congestion effect and changes in the speed of vehicle flow during morning and evening peaks in a large- or medium-sized city, the piecewise function is used to capture the rules of the time-varying speed of vehicles, which are very important in modelling their fuel consumption and CO2 emission. A joint optimization model of the green vehicle scheduling and routing problem with time-varying speeds is presented in this study. Extra wages during nonworking periods and soft time-window constraints are considered. A heuristic algorithm based on the adaptive large neighborhood search algorithm is also presented. Finally, a numerical simulation example is provided to illustrate the optimization model and its algorithm. Results show that, (1) the shortest route is not necessarily the route that consumes the least energy, (2) the departure time influences the vehicle fuel consumption and CO2 emissions and the optimal departure time saves on fuel consumption and reduces CO2 emissions by up to 5.4%, and (3) extra driver wages have significant effects on routing and departure time slot decisions.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.
Energy Use and Power Levels in New Monitors and Personal Computers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, Judy A.; Homan, Gregory K.; Mahajan, Akshay
2002-07-23
Our research was conducted in support of the EPA ENERGY STAR Office Equipment program, whose goal is to reduce the amount of electricity consumed by office equipment in the U.S. The most energy-efficient models in each office equipment category are eligible for the ENERGY STAR label, which consumers can use to identify and select efficient products. As the efficiency of each category improves over time, the ENERGY STAR criteria need to be revised accordingly. The purpose of this study was to provide reliable data on the energy consumption of the newest personal computers and monitors that the EPA can usemore » to evaluate revisions to current ENERGY STAR criteria as well as to improve the accuracy of ENERGY STAR program savings estimates. We report the results of measuring the power consumption and power management capabilities of a sample of new monitors and computers. These results will be used to improve estimates of program energy savings and carbon emission reductions, and to inform rev isions of the ENERGY STAR criteria for these products. Our sample consists of 35 monitors and 26 computers manufactured between July 2000 and October 2001; it includes cathode ray tube (CRT) and liquid crystal display (LCD) monitors, Macintosh and Intel-architecture computers, desktop and laptop computers, and integrated computer systems, in which power consumption of the computer and monitor cannot be measured separately. For each machine we measured power consumption when off, on, and in each low-power level. We identify trends in and opportunities to reduce power consumption in new personal computers and monitors. Our results include a trend among monitor manufacturers to provide a single very low low-power level, well below the current ENERGY STAR criteria for sleep power consumption. These very low sleep power results mean that energy consumed when monitors are off or in active use has become more important in terms of contribution to the overall unit energy consumption (UEC). Cur rent ENERGY STAR monitor and computer criteria do not specify off or on power, but our results suggest opportunities for saving energy in these modes. Also, significant differences between CRT and LCD technology, and between field-measured and manufacturer-reported power levels reveal the need for standard methods and metrics for measuring and comparing monitor power consumption.« less
Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan
NASA Astrophysics Data System (ADS)
Nazzal, Ali; Oki, Masato
Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.
Saving energy for the data collection point in WBAN network
NASA Astrophysics Data System (ADS)
Nguyen-Duc, Toan; Kamioka, Eiji
2017-11-01
Wireless sensor networking (WSN) has been rapidly developed and become essential in various domains including health care systems. Such systems use WSN to collect real-time medical sensed data, aiming at improving the patient safety. For instance, patients suffered from adverse events, i.e., cardiac or respiratory arrests, are monitored so as to prevent them from getting harm. Sensors are placed on, in or near the patients' body to continuously collect sensing data such as the electrocardiograms, blood oxygenation, breathing, and heart rate. In this case, the sensors form a subcategory of WSN called wireless body area network (WBAN). In WBAN, sensing data are sent to one or more data collection points called personal server (PS). The role of PS is important since it forwards sensed data, to a medical server via a Bluetooth/WLAN connection in real time to support storage of information and real-time diagnosis, the device can also issue a notification of an emergency status. Since PS is a battery-based device, when its battery is empty, it will disconnect the sensed medical data with the rest network. To best of our knowledge, very few studies that focus on saving energy for the PS. To this end, this work investigates the trade-off between energy consumption for wireless communication and the amount of sensing data. An energy consumption model for wireless communication has been proposed based on direct measurement using real testbed. According to our findings, it is possible to save energy for the PS by selecting suitable wireless technology to be used based on the amount of data to be transmitted.
Energy saving achieved by limited filamentous bulking sludge under low dissolved oxygen.
Guo, Jian-Hua; Peng, Yong-Zhen; Peng, Cheng-Yao; Wang, Shu-Ying; Chen, Ying; Huang, Hui-Jun; Sun, Zhi-Rong
2010-02-01
Limited filamentous bulking caused by low dissolved oxygen (DO) was proposed to establish a low energy consumption wastewater treatment system. This method for energy saving was derived from two full-scale field observations, which showed pollutants removal would be enhanced and energy consumption could be reduced by at least 10% using limited filamentous bulking. Furthermore, preliminary investigation including the abundance evaluation and the identification of filamentous bacteria demonstrated that the limited filamentous bulking could be repeated steadily in a lab-scale anoxic-oxic reactor fed with domestic wastewater. The sludge loss did not occur in the secondary clarifier, while COD and total nitrogen removal efficiencies were improved by controlling DO for optimal filamentous bacterial population. Suspended solids in effluent were negligible and turbidity was lower than 2 NTU, which were distinctly lower than those under no bulking. Theoretical and experimental results indicated the aeration consumption could be saved by the application of limited filamentous bulking.
Design and evaluation of Continuous Descent Approach as a fuel-saving procedure
NASA Astrophysics Data System (ADS)
Jin, Li
Continuous Descent Approach (CDA), which is among the key concepts of the Next Generation Air Transportation System (NextGen), is a fuel economical procedure, but requires increased separation to accommodate spacing uncertainties among arriving aircraft. Such negative impact is often overlooked when benefits are estimated. Although a considerable number of researches have been devoted to the estimation of potential fuel saving of CDA, few have attempted to explain the fuel saving observed in field tests from an analytical point of view. This research gives insights into the reasons why CDA saves fuel, and a number of design guidelines for CDA procedures are derived. The analytical relationship between speed, altitude, and time-cumulative fuel consumption is derived based on Base of Aircraft Data (BADA) Total Energy Model. Theoretical analysis implies that speed profile has an impact as substantial as, if not more than, vertical profile on the fuel consumption in the terminal area. In addition, CDA is not intrinsically a fuel-saving procedure: whether CDA saves fuel or not is contingent upon whether the speed profile is properly designed or not. Based on this model, the potential fuel savings due to CDA at San Francisco International Airport were estimated, and the accuracy of this estimation is analyzed. Possible uncertainties in this fuel estimation primarily resulted from the modeled CDA procedure and the inaccuracy of BADA. This thesis also investigates the fuel savings due to CDAs under high traffic conditions, counting not only the savings benefiting from optimal vertical profiles but also the extra fuel burn resulting from the increased separations. The simulated CDAs traffic is based on radar track data, and deconflicted by a scheduling algorithm that targets minimized delays. The delays are absorbed by speed change and path stretching, accounting for the air traffic controls that are entailed by CDAs. The fuel burn statistics calculated based on the BADA Total Energy Model reveals that the CDAs save on average 171.87 kg per arrival, but the number is discounted by delay absorption. The savings diminish as the arrival demand increases, and could be even negative due to large delays. The throughput analysis demonstrated that the impact of CDA on airport capacity is insignificant and tolerable. The Atlanta International Airport was used as the testbed for sensitivity analysis, and the New York Metroplex was used as the test bed for throughput analysis.
Cost effectiveness of brief interventions for reducing alcohol consumption.
Wutzke, S E; Shiell, A; Gomel, M K; Conigrave, K M
2001-03-01
The direct costs and health effects of a primary-care-based brief intervention for hazardous alcohol consumption were examined. The total cost of the intervention was calculated from costs associated with: marketing the intervention programme; providing training and support in the use of the intervention materials; physician time required for providing brief advice for 'at-risk' drinkers. The effect of the intervention on health outcomes was expressed in terms of number of life years saved by preventing alcohol-related deaths. This was derived by combining estimates of the impact of the programme if it were implemented nationally with available evidence on the health effects of excess alcohol consumption. Results are based on international trial evidence showing the physical resources required by the intervention and its effectiveness combined with Australian price data. The costs associated with screening and brief advice using the current intervention programme range from Aus$19.14 to Aus$21.50. The marginal costs per additional life year saved were below Aus$1873. The robustness of the model used is supported by an extensive sensitivity analysis. In comparison with existing health promotion strategies the costs and effects of the current intervention are highly encouraging.
Data analytics for simplifying thermal efficiency planning in cities
Abdolhosseini Qomi, Mohammad Javad; Noshadravan, Arash; Sobstyl, Jake M.; Toole, Jameson; Ferreira, Joseph; Pellenq, Roland J.-M.; Ulm, Franz-Josef; Gonzalez, Marta C.
2016-01-01
More than 44% of building energy consumption in the USA is used for space heating and cooling, and this accounts for 20% of national CO2 emissions. This prompts the need to identify among the 130 million households in the USA those with the greatest energy-saving potential and the associated costs of the path to reach that goal. Whereas current solutions address this problem by analysing each building in detail, we herein reduce the dimensionality of the problem by simplifying the calculations of energy losses in buildings. We present a novel inference method that can be used via a ranking algorithm that allows us to estimate the potential energy saving for heating purposes. To that end, we only need consumption from records of gas bills integrated with a building's footprint. The method entails a statistical screening of the intricate interplay between weather, infrastructural and residents' choice variables to determine building gas consumption and potential savings at a city scale. We derive a general statistical pattern of consumption in an urban settlement, reducing it to a set of the most influential buildings' parameters that operate locally. By way of example, the implications are explored using records of a set of (N = 6200) buildings in Cambridge, MA, USA, which indicate that retrofitting only 16% of buildings entails a 40% reduction in gas consumption of the whole building stock. We find that the inferred heat loss rate of buildings exhibits a power-law data distribution akin to Zipf's law, which provides a means to map an optimum path for gas savings per retrofit at a city scale. These findings have implications for improving the thermal efficiency of cities' building stock, as outlined by current policy efforts seeking to reduce home heating and cooling energy consumption and lower associated greenhouse gas emissions. PMID:27097652
Possibilities of Architectural Lighting to Create New Style
NASA Astrophysics Data System (ADS)
Chudinova, V. G.; Bokova, O. R.
2017-11-01
The article presents the argumentation of the provision on the style-forming potential of the lighting design the sphere of which is interpreted in a wide range of genres. The area of the intersection of form-building technological and artistic aspects lies in the field of ecology which includes not only energy saving, but also the well-being of the human and the society. The theory and practice of designing the night-time image of architectural ensembles, buildings and landscapes develops much slower than the implementation of light solutions in the advertising industry. In most cases, the possibilities of lighting design are used only in the field of decorative lighting despite their huge aesthetic potential and rapidly improving technologies. The request for innovation and uniqueness usually arises on the basis of image and political ambitions of large corporations or for the positioning of powerful brands. The success of such projects becomes a driver for both creation and promotion of innovative solutions. However, in a broader scientific sense, not only the design of artificial light systems but also the optimization of the daylight usage falls into the sphere lighting design. The need for the new methods of architectural shaping is dictated by the need to introduce in the building of resource-saving lighting technologies, ecological infrastructure including alternative energy sources. The article gives the examples of different lighting design genres supplemented with illustrations. The conclusions concern the prospective directions and tasks of scientific research in the field of lighting design.
Reducing power usage on demand
NASA Astrophysics Data System (ADS)
Corbett, G.; Dewhurst, A.
2016-10-01
The Science and Technology Facilities Council (STFC) datacentre provides large- scale High Performance Computing facilities for the scientific community. It currently consumes approximately 1.5MW and this has risen by 25% in the past two years. STFC has been investigating leveraging preemption in the Tier 1 batch farm to save power. HEP experiments are increasing using jobs that can be killed to take advantage of opportunistic CPU resources or novel cost models such as Amazon's spot pricing. Additionally, schemes from energy providers are available that offer financial incentives to reduce power consumption at peak times. Under normal operating conditions, 3% of the batch farm capacity is wasted due to draining machines. By using preempt-able jobs, nodes can be rapidly made available to run multicore jobs without this wasted resource. The use of preempt-able jobs has been extended so that at peak times machines can be hibernated quickly to save energy. This paper describes the implementation of the above and demonstrates that STFC could in future take advantage of such energy saving schemes.
Energy performance of semi-transparent PV modules for applications in buildings
NASA Astrophysics Data System (ADS)
Fung, Yu Yan
Owing to the increasing awareness on energy conservation and environmental protection, building-integrated photovoltaic (BIPV) has been developed rapidly in the past decade. A number of research studies have been conducted on the energy performance of BIPV systems. However, most of the previous studies focused on the systems that incorporated with opaque type PV modules, little attention has been devoted to semi-transparent type PV modules, which have been commonly integrated in modern architectures. This thesis aims at evaluating the energy performance of the semi-transparent BIPV modules, including heat gains to the indoor environment, power generation from the PV modules and daylight utilization. Solar radiation intensity on PV module's surfaces is an essential parameter for assessing energy performance of the PV modules. Different slope solar radiation models are analyzed and compared. The model that best suits Hong Kong situations is selected for the further development of the energy performance of the BIPV modules. The optimum orientation and tilted angle are determined in the analysis. In addition to the solar radiation models, a detailed investigation on the heat gain through the semi-transparent BIPV modules is carried out in this study. A one-dimensional transient heat transfer model, the SPVHG model, for evaluating the thermal performance of the semi-transparent BIPV modules is developed. The SPVHG model considers in detail the energy that is transmitted, absorbed and reflected in each element of the BIPV modules such as solar cells and glass layers. A computer program of the model is written accordingly. By applying the SPVHG model, the heat gain through the semi-transparent BIPV module of any thickness can be determined for any solar irradiance level. The annual performance can also be assessed by inputting annual weather data to the model. In order to verify the SPVHG model, laboratory tests have been carried out on semi-transparent BIPV modules. A well-insulated calorimeter box and an adjustable steady-state type solar simulator which can provide up to 1600 W/m2 have been used in the tests. Energy that transmitted through the semi-transparent BIPV modules and entered the calorimeter box was evaluated. It was found that the experimental results and the simulated results support each other. The SPVHG model is validated and can be used for further studies. Other than heat transfer, power production and the daylight utilization are also the vital parts in the energy performance assessment of the semi-transparent BIPV module for applications in building facades. Power generation models of both opaque and semi-transparent BIPV modules are investigated in this study. In order to test the validity of the power generation model, measurements on a BIPV system of an existing building are carried out. The measurement results reveal a good validity of the power generation model. Only a minor modification to the model is required. The daylight utilization is evaluated by using an indoor illuminance model. The model estimates the mean internal illuminance on the working plane of a room when there is both sunlight and skylight. Consequently, the power saving due to the daylight utilization can be determined. By using the SPVHG model together with the power generation model and the indoor illuminance model, the energy performance, in terms of electricity benefit, of building facades that incorporated with semi-transparent BIPV modules is evaluated. Different scenarios are studied by changing various parameters such as the window to wall ratios, thickness and efficiency of the solar cells. The results show that the solar cells within the semi-transparent BIPV modules significantly reduce the solar heat gain and thus reduce the power consumption of air-conditioning systems. Taking into account the impacts of PV electricity generation and daylight utilization, the optimum solar cell area ratio in the PV modules varies from 0.7 to 0.9 for different window-to-wall ratios of the building facade. The largest net electricity benefit of the BIPV facade under the simulation conditions is around 120 kWh/m 2. The SPVHG model developed in this study is a precise model for calculating the amount of heat gains through the semi-transparent BIPV modules. By considering also the power generation and daylight utilization, the electricity benefit of different BIPV facade configurations can be simulated. This information should help engineers predict the cooling load due to the BIPV facade and thus review their designs for energy efficiency optimization. On the whole, the results of this study provide valuable reference to local engineers, designers and professionals for efficient BIPV facade applications.
NASA Astrophysics Data System (ADS)
Shah, Ushik D.
Lighting contributes to a high percentage of the total energy use in office buildings. The lack of financial incentive often dissuades office workers from trying to save electricity at their work place. This thesis aims at reducing the total power consumed by an office building by using persuasive technologies on the occupants to promote environmentally conscious and energy saving behavior. A three week field study was conducted by providing occupants of an office building feedback about their energy consumption along with messages to encourage them to save energy. Feedback was provided via television screens and flyers placed strategically at the study location, the fourth floor of the Knoy Hall of Technology, Purdue University, West Lafayette campus. The results obtained from the analysis of data showed no change in energy consumption post intervention. Group feedback thus proved to be ineffective in encouraging occupants of this office building to reduce their energy consumption. This thesis presents the findings of the study and discusses recommendations and future scope for similar studies.
NASA Technical Reports Server (NTRS)
Monk, T. H.; Buysse, D. J.; Billy, B. D.; Kennedy, K. S.; Kupfer, D. J.
1997-01-01
As part of a larger bedrest study involving various life science experiments, a study was conducted on the effects of 17 days of continuous bedrest and elimination of daylight on circadian rectal temperature rhythms, mood, alertness, and sleep (objective and diary) in eight healthy middle-aged men. Sleep was timed from 2300 to 0700 hours throughout. Three 72-hour measurement blocks were compared: ambulatory prebedrest, early bedrest (days 5-7), and late bedrest (days 15-17). Temperature rhythms showed reduced amplitude and later phases resulting from the bedrest conditions. This was associated with longer nocturnal sleep onset latencies and poorer subjectively rated sleep but with no reliable changes in any of the other sleep parameters. Daily changes in posture and/or exposure to daylight appear to be important determinants of a properly entrained circadian system.
Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandez, Nicholas E.P.; Katipamula, Srinivas; Wang, Weimin
Commercial buildings in the United States use about 18 Quadrillion British thermal units (Quads) of primary energy annually . Studies have shown that as much as 30% of building energy consumption can be avoided by using more accurate sensing, using existing controls better, and deploying advanced controls; hence, the motivation for the work described in this report. Studies also have shown that 10% to 20% of the commercial building peak load can be temporarily managed/curtailed to provide grid services. Although many studies have indicated significant potential for reducing the energy consumption in commercial buildings, very few have documented the actualmore » savings. The studies that did so only provided savings at the whole building level, which makes it difficult to assess the savings potential of each individual measure deployed.« less
Sunlight Responsive Thermochromic Window System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Millett, F,A; Byker,H, J
2006-10-27
Pleotint has embarked on a novel approach with our Sunlight Responsive Thermochromic, SRT™, windows. We are integrating dynamic sunlight control, high insulation values and low solar heat gain together in a high performance window. The Pleotint SRT window is dynamic because it reversibly changes light transmission based on thermochromics activated directly by the heating effect of sunlight. We can achieve a window package with low solar heat gain coefficient (SHGC), a low U value and high insulation. At the same time our windows provide good daylighting. Our innovative window design offers architects and building designers the opportunity to choose theirmore » desired energy performance, excellent sound reduction, external pane can be self-cleaning, or a resistance to wind load, blasts, bullets or hurricanes. SRT windows would provide energy savings that are estimated at up to 30% over traditional window systems. Glass fabricators will be able to use existing equipment to make the SRT window while adding value and flexibility to the basic design. Glazing installers will have the ability to fit the windows with traditional methods without wires, power supplies and controllers. SRT windows can be retrofit into existing buildings,« less
Hurricane Isaac by Night [annotated
2017-12-08
NASA image acquired August 29, 2012 1:57 a.m EDT Hurricane Isaac lit up by moonlight as it spins over the city of New Orleans, La. at 1:57 am central daylight savings time the morning of August 29, 2012. The Suomi National Polar-orbiting Partnership (NPP) satellite captured these images with its Visible Infrared Imaging Radiometer Suite (VIIRS). The "day-night band" of VIIRS detects light in a range of wavelengths from green to near-infrared and uses light intensification to enable the detection of dim signals. Suomi NPP is the result of a partnership between NASA, the National Oceanic and Atmospheric Administration and the Department of Defense. Image Credit: NASA/NOAA, Earth Observatory NASA Earth Observatory image by Jesse Allen and Robert Simmon, using VIIRS Day Night Band data. Credit: NASA Earth Observatory NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
OTTER: An Optimized Transit Tool And Easy Reference
2016-03-01
as stated in the CNO’s Position Report: 2014. While a number of fuel -saving measures have been implemented in recent years, the effects of...saving measures have been implemented in recent years, the effects of operational transit speed on fuel consumption have not been adequately...their estimated savings As clearly seen, operating configuration has the most effect by far on fuel savings. Source: Fonte S (2009). In 2015
Lerche, Catharina M; Heerfordt, Ida M; Heydenreich, Jakob; Wulf, Hans Christian
2016-02-29
Daylight-mediated photodynamic therapy (daylight PDT) is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor "daylight PDT" and investigated their ability to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light-emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB) radiation passes through the greenhouse glass, so sun protection is not needed.
Lerche, Catharina M.; Heerfordt, Ida M.; Heydenreich, Jakob; Wulf, Hans Christian
2016-01-01
Daylight-mediated photodynamic therapy (daylight PDT) is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor “daylight PDT” and investigated their ability to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light-emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB) radiation passes through the greenhouse glass, so sun protection is not needed. PMID:26938525
Fast and memory efficient text image compression with JBIG2.
Ye, Yan; Cosman, Pamela
2003-01-01
In this paper, we investigate ways to reduce encoding time, memory consumption and substitution errors for text image compression with JBIG2. We first look at page striping where the encoder splits the input image into horizontal stripes and processes one stripe at a time. We propose dynamic dictionary updating procedures for page striping to reduce the bit rate penalty it incurs. Experiments show that splitting the image into two stripes can save 30% of encoding time and 40% of physical memory with a small coding loss of about 1.5%. Using more stripes brings further savings in time and memory but the return diminishes. We also propose an adaptive way to update the dictionary only when it has become out-of-date. The adaptive updating scheme can resolve the time versus bit rate tradeoff and the memory versus bit rate tradeoff well simultaneously. We then propose three speedup techniques for pattern matching, the most time-consuming encoding activity in JBIG2. When combined together, these speedup techniques can save up to 75% of the total encoding time with at most 1.7% of bit rate penalty. Finally, we look at improving reconstructed image quality for lossy compression. We propose enhanced prescreening and feature monitored shape unifying to significantly reduce substitution errors in the reconstructed images.
Strategies to improve energy efficiency in sewage treatment plants
NASA Astrophysics Data System (ADS)
Au, Mau Teng; Pasupuleti, Jagadeesh; Chua, Kok Hua
2013-06-01
This paper discusses on strategies to improve energy efficiency in Sewage Treatment Plant (STP). Four types of STP; conventional activated sludge, extended aeration, oxidation ditch, and sequence batch reactor are presented and strategized to reduce energy consumption based on their influent flow. Strategies to reduce energy consumption include the use of energy saving devices, energy efficient motors, automation/control and modification of processes. It is envisaged that 20-30% of energy could be saved from these initiatives.
Dixit, Abhishek; Lannoo, Bart; Colle, Didier; Pickavet, Mario; Demeester, Piet
2012-12-10
The optical network unit (ONU), installed at a customer's premises, accounts for about 60% of power in current fiber-to-the-home (FTTH) networks. We propose a power consumption model for the ONU and evaluate the ONU power consumption in various next generation optical access (NGOA) architectures. Further, we study the impact of the power savings of the ONU in various low power modes such as power shedding, doze and sleep.
Is Advanced Real-Time Energy Metering Sufficient to Persuade People to Save Energy?
NASA Astrophysics Data System (ADS)
Ting, L.; Leite, H.; Ponce de Leão, T.
2012-10-01
In order to promote a low-carbon economy, EU citizens may soon be able to check their electricity consumption from smart meter. It is hoped that smart meter can, by providing real-time consumption and pricing information to residential users, help reducing demand for electricity. It is argued in this paper that, according the Elaborative Likelihood Model (ELM), these methods are most likely to be effective when consumers perceive the issue of energy conservation relevant to their lives. Nevertheless, some fundamental characteristics of these methods result in limited amount of perceived personal relevance; for instance, energy expenditure expense may be relatively small comparing to other household expenditure like mortgage and consumption information does not enhance interpersonal trust. In this paper, it is suggested that smart meter can apply the "nudge" approaches which respond to ELM as the use of simple rules to make decision, which include the change of feedback delivery and device design.
Modelling Electrical Energy Consumption in Automotive Paint Shop
NASA Astrophysics Data System (ADS)
Oktaviandri, Muchamad; Safiee, Aidil Shafiza Bin
2018-03-01
Industry players are seeking ways to reduce operational cost to sustain in a challenging economic trend. One key aspect is an energy cost reduction. However, implementing energy reduction strategy often struggle with obstructions, which slow down their realization and implementation. Discrete event simulation method is an approach actively discussed in current research trend to overcome such obstructions because of its flexibility and comprehensiveness. Meanwhile, in automotive industry, paint shop is considered the most energy consumer area which is reported consuming about 50%-70% of overall automotive plant consumption. Hence, this project aims at providing a tool to model and simulate energy consumption at paint shop area by conducting a case study at XYZ Company, one of the automotive companies located at Pekan, Pahang. The simulation model was developed using Tecnomatix Plant Simulation software version 13. From the simulation result, the model was accurately within ±5% for energy consumption and ±15% for maximum demand after validation with real system. Two different energy saving scenarios were tested. Scenario 1 was based on production scheduling approach under low demand situation which results energy saving up to 30% on the consumption. Meanwhile scenario 2 was based on substituting high power compressor with the lower power compressor. The results were energy consumption saving of approximately 1.42% and maximum demand reduction about 1.27%. This approach would help managers and engineers to justify worthiness of investment for implementing the reduction strategies.
Daylighting Makes a Difference.
ERIC Educational Resources Information Center
Heschong, Lisa; Knecht, Carey
2002-01-01
Examined the role of daylight in student achievement in three schools and found a uniformly positive and statistically significant correlation between the presence of more daylight and better student test scores. Offers guidelines on designing daylit classrooms. (EV)
Morán López, Jesús Manuel; Enciso Izquierdo, Fidel Jesús; Luengo Pérez, Luis Miguel; Beneítez Moralejo, Belén; Piedra León, María; de Luis, Daniel A; Amado Señaris, José Antonio
2017-10-01
DRM is a highly prevalent condition in Spanish hospitals and is associated to increased healthcare costs. Costs associated to DRM were calculated using the methods of the PREDyCES study. The potential savings derived from specialized nutritional treatment were calculated by extrapolating the results of the SNAQ strategy. Median cost per procedure in patients with DRM was €9,679.85, with a final cost of €28,700,775.2. The cost of each patient with DRM was 2.63 times higher than the cost of patients with no DRM. The potential cost saving associated to specialized nutritional treatment was estimated at €1,682,317.28 (5.86% of total cost associated to DRM). Patients with DRM showed a higher consumption of financial resources as compared to well-nourished patients. Specialized nutritional treatment is a potential cost-saving procedure. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.
Analysis of Time-of-Day Energy Demand and Supply in University and Hospital
NASA Astrophysics Data System (ADS)
Shimazaki, Yoichi
The aim of this study was to estimate the time-of-day energy demand in University of Yamanashi. Our University consisted of Kofu campus (Faculty of Education & Human Sciences and Faculty of Engineering) and Faculty of Medicine campus (Faculty of Medicine and University Hospital). The energy data of 4 facilities were classified into hot water, heating, cooling and electric power demands based on electric power consumptions, city gas and heavy oil from 1996 to 2005. For 10 years, primary energy increased 1.2 times in the whole of the university. The amount of electric power consumption was 63% in the fuel classification. The amount of electric power consumption of faculty reacted to the change in temperature greatly. In 2005, it was found that thermoelectric-ratios for 4 facilities, i.e. Education, Engineering, Medicine and Hospital were 2.3, 1.5, 2.0 and 2.7 respectively. These data are very useful for the energy saving and energy management of university.
Lighting system combining daylight concentrators and an artificial source
Bornstein, Jonathan G.; Friedman, Peter S.
1985-01-01
A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.
Kittelmann, Jörg; Ottens, Marcel; Hubbuch, Jürgen
2015-04-15
High-throughput batch screening technologies have become an important tool in downstream process development. Although continuative miniaturization saves time and sample consumption, there is yet no screening process described in the 384-well microplate format. Several processes are established in the 96-well dimension to investigate protein-adsorbent interactions, utilizing between 6.8 and 50 μL resin per well. However, as sample consumption scales with resin volumes and throughput scales with experiments per microplate, they are limited in costs and saved time. In this work, a new method for in-well resin quantification by optical means, applicable in the 384-well format, and resin volumes as small as 0.1 μL is introduced. A HTS batch isotherm process is described, utilizing this new method in combination with optical sample volume quantification for screening of isotherm parameters in 384-well microplates. Results are qualified by confidence bounds determined by bootstrap analysis and a comprehensive Monte Carlo study of error propagation. This new approach opens the door to a variety of screening processes in the 384-well format on HTS stations, higher quality screening data and an increase in throughput. Copyright © 2015 Elsevier B.V. All rights reserved.
Building an Energy-efficient Uplink and Downlink Delay Aware TDM-PON System
NASA Astrophysics Data System (ADS)
Newaz, S. H. Shah; Jang, Min Seok; Alaelddin, Fuad Yousif Mohammed; Lee, Gyu Myoung; Choi, Jun Kyun
2016-05-01
With the increasing concern over the energy expenditure due to rapid ICT expansion and growth of Internet traffic volume, there is a growing trend towards developing energy-efficient ICT solutions. Passive Optical Network (PON), which is regarded as a key enabler to facilitate high speed broadband connection to individual subscribers, is considered as one of the energy-efficient access network technologies. However, an immense amount of research effort can be noticed in academia and industries to make PON more energy-efficient. In this paper, we aim at improving energy saving performance of Time Division Multiplexing (TDM)-PON, which is the most widely deployed PON technology throughout the world. A commonly used approach to make TDM-PON energy-efficient is to use sleep mode in Optical Network Units (ONUs), which are the customer premises equipment of a TDM-PON system. However, there is a strong trade-off relationship between traffic delay performance of an ONU and its energy saving (the longer the sleep interval length of an ONU, the lower its energy consumption, but the higher the traffic delay, and vice versa). In this paper, we propose an Energy-efficient Uplink and Downlink Delay Aware (EUDDA) scheme for TDM-PON system. The prime object of EUDDA is to meet both downlink and uplink traffic delay requirement while maximizing energy saving performance of ONUs as much as possible. In EUDDA, traffic delay requirement is given more priority over energy saving. Even so, it still can improve energy saving of ONUs noticeably. We evaluate performance of EUDDA in front of two existing solutions in terms of traffic delay, jitter, and ONU energy consumption. The performance results show that EUDDA significantly outperforms the other existing solutions.
NASA Technical Reports Server (NTRS)
Kraus, E. F.; Vanabkoude, J. C.
1976-01-01
The fuel saving potential and cost effectiveness of numerous operational and technical options proposed for reducing the fuel consumption of the U.S. commercial airline fleet was examined and compared. The impact of the most promising fuel conserving options on fuel consumption, passenger demand, operating costs and airline profits when implemented in the U.S. domestic and international airline fleets was determined. A forecast estimate was made of the potential fuel savings achievable in the U.S. scheduled air transportation system. Specifically, the means for reducing the jet fuel consumption of the U.S. scheduled airlines in domestic and international passenger operations were investigated. A design analysis was made of two turboprop aircraft as possible fuel conserving derivatives of the DC-9-30.
Cogeneration technology alternatives study. Volume 1: Summary report
NASA Technical Reports Server (NTRS)
1980-01-01
Data and information in the area of advanced energy conversion systems for industrial congeneration applications in the 1985-2000 time period was studied. Six current and thirty-one advanced energy conversion systems were defined and combined with appropriate balance-of-plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a framework for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. Various cogeneration strategies were analyzed and both topping and bottoming (using industrial by-product heat) applications were included. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Typically fuel energy savings of 10 to 25 percent were predicted compared to traditional on-site furnaces and utility electricity. With the variety of industrial requirements, each advanced technology had attractive applications. Overall, fuel cells indicated the greatest fuel energy savings and emission reductions. Gas turbines and combined cycles indicated high overall annual cost savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal-derived fuels, or coal with advanced fluid bed combustion or on-site gasification systems.
Zhou, Minghua; Yu, Jiaguo
2008-04-15
A simple method for preparing highly daylight-induced photoactive nanocrystalline C,N,S-tridoped TiO2 powders was developed by a solid-phase reaction. The as-prepared TiO2 powders were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflectance spectra, N2 adsorption-desorption measurements and transmission electron microscopy (TEM). The photocatalytic activity was evaluated by the photocatalytic oxidation of formaldehyde under daylight irradiation in air. The results show that daylight-induced photocatalytic activities of the as-prepared TiO2 powders were improved by C,N,S-tridoping. The C,N,S-tridoped TiO2 powders exhibited stronger absorption in the near UV and visible-light region with red shift in the band-gap transition. When the molar ratio of CS(NH2)2 to xerogel TiO2 powders (prepared by hydrolysis of Ti(OC4H9)4 in distilled water) (R) was kept in 3, the daylight-induced photocatalytic activities of the as-prepared C,N,S-tridoped TiO2 powders were about more than six times greater than that of Degussa P25 and un-doped TiO2 powders. The high activities of the C,N,S-tridoped TiO2 can be attributed to the results of the synergetic effects of strong absorption in the near UV and visible-light region, red shift in adsorption edge and two phase structures of un-doped TiO2 and C,N,S-tridoped TiO2.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D.; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed. PMID:24586299
Energy savings potential from improved building controls for the US commercial building sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin
The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sectormore » energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.« less
Assessing the Decline in the National Saving Rate
1993-04-01
and on the Contributions of the Government and Private Sectors xii 1. NIPA Measure of National Saving as a Percentage of Gross National Product 2 2...System of National Accounts Measure of National Saving Rates 3 3. Per Capita Gross Domestic Product in 1990 U.S. Dollars Adjusted for Purchasing Power... Product 4 6. Nonresidential and Residential Capital Consumption as a Percentage of Gross National Product and Capital Stocks 10 7. Net National Saving as
When energy saving advice leads to more, rather than less, consumption
NASA Astrophysics Data System (ADS)
Revell, Kirsten M. A.; Stanton, Neville A.
2017-01-01
Energy saving technology that relies on behaviour change fails to deliver on its promise. Energy saving advice also has limited effect. This paper examines and reveals how technology and energy saving advice interacts with householders' thought processes to influence energy consumption. A case study of three households that held a 'Feedback' mental model of the home heating thermostat, as defined by Kempton [1986. 'Two Theories of Home Heat Control'. Cognitive Science 10 (1): 75-90], was undertaken to understand the driver behind differences in their home heating strategies, and the effect on energy consumption. Analysis was undertaken from five different data sources comprising: (1) boiler on durations, (2) thermostat set point adjustments, (3) self-reported strategies with home heating controls, (4) user mental model descriptions of the home heating system, and (5) Interview transcripts. The authors found that differences in user mental models of home heating at the system level explained differences in the strategies chosen at the control device level. Differences in boiler on periods were found to relate to limitations of the 'Feedback' mental model; that is, the model fails to consider the effect of the movement of warm air within the home and the impact of internal/external temperature differentials on heat loss rates. The authors argue that technology and advice should be tailored to the thought processes adopted by householders in order to promote behaviour that would realise intended energy savings.
Aggressive Strategies for Residential Energy and Carbon Savings by 2025
NASA Astrophysics Data System (ADS)
Ling, F. H.; Kammen, D. M.
2004-12-01
Energy efficiency technologies and practices have long been recognized as a low-cost, often least cost, option that can be deployed widely throughout the economy (Steve Nadel, 2002; Donald A. Hanson and John A. Laitner, 2003). We are engaged in a review of technology-based energy savings options throughout the U. S. economy with a joint focus on both immediate savings opportunities and long-term strategies for accelerating the innovation process and pipeline. For the near term, we developed scenarios based on available 'off the shelf' technologies and practices for achieving minimum energy consumption in lighting, standby power in electronics, and miscellaneous end-uses in the U.S. residential sector. In the business-as-usual (BAU) case, energy consumption continues to grow despite innovations at a current rate of 1.7 percent/year (Laitner, 2004). Nevertheless, the need for developing new energy supplies can be mitigated through the use of 'best current technologies' as the industry norm in 2025. Figure 1 (see URL below) shows this reduction in energy consumption and greenhouse gas emissions. The BAU model corresponds to the current rate of 'decarbonization' in the overall U.S. economy (Energy Information Administration, 2004). Over a twenty-year period, about 2 billion metric tons of carbon dioxide and 30 quads of primary fuel could be saved through the introduction of "best current technology" with the greatest reductions in the area of lighting technologies. In 2025, 1.5 quads of primary energy is saved with the breakdown in end-use electricity saved as follows: 113 TWh (0.39 quads), 70.8 TWh (0.24 quads), and 62 TWh (0.21 quads) for residential lighting, appliance standards, and standby power respectively. In addition, there is empirical evidence from specific technology sectors, from statewide programs in California, as well as on theoretical grounds (Laitner, 2004) that innovation and decarbonization rates of 3 to 5 percent/year have at times been, and could again be achieved. While such high rates of innovation do not usually sustain themselves for more than a few years, innovation rates higher than the current 1.7 percent/year are also explored in this study. Acknowledgement: Alliance to Save Energy (ASE) and Energy Foundation References: Energy Information Administration. "Annual Energy Outlook 2004." Washington, DC: U.S. Department of Energy, 2004. Hanson, Donald A. and Laitner, John A. "Skip". "An Integrated Analysis of Policies That Increase Investments in Advanced Energy-Efficient/Low-Carbon Technologies." Energy Economics, 2003. Laitner, J. A. "How far energy efficiency." 2004. Nadel, Steve. "Appliance and Equipment Efficiency Standards." Annual Reviews, 2002.
Residential solar hot water system--Tempe, Arizona
NASA Technical Reports Server (NTRS)
1981-01-01
Domestic hot water for single story home is heated by two 4 by 8 foot solar collectors. Solar energy saved 5.54 million Btu in six month period; savings with increased water consumption would be significantly higher.
A tuneable approach to uniform light distribution for artificial daylight photodynamic therapy.
O'Mahoney, Paul; Haigh, Neil; Wood, Kenny; Brown, C Tom A; Ibbotson, Sally; Eadie, Ewan
2018-06-16
Implementation of daylight photodynamic therapy (dPDT) is somewhat limited by variable weather conditions. Light sources have been employed to provide artificial dPDT indoors, with low irradiances and longer treatment times. Uniform light distribution across the target area is key to ensuring effective treatment, particularly for large areas. A novel light source is developed with tuneable direction of light emission in order to meet this challenge. Wavelength composition of the novel light source is controlled such that the protoporphyrin-IX (PpIX) weighed spectra of both the light source and daylight match. The uniformity of the light source is characterised on a flat surface, a model head and a model leg. For context, a typical conventional PDT light source is also characterised. Additionally, the wavelength uniformity across the treatment site is characterised. The PpIX-weighted spectrum of the novel light source matches with PpIX-weighted daylight spectrum, with irradiance values within the bounds for effective dPDT. By tuning the direction of light emission, improvements are seen in the uniformity across large anatomical surfaces. Wavelength uniformity is discussed. We have developed a light source that addresses the challenges in uniform, multiwavelength light distribution for large area artificial dPDT across curved anatomical surfaces. Copyright © 2018. Published by Elsevier B.V.
Atmospheric Science Data Center
2014-09-25
Solar Noon (GMT time) The time when the sun is due south in the northern hemisphere or due north in the southern ... The average cosine of the angle between the sun and directly overhead during daylight hours. Cosine solar ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitehead, Camilla Dunham; McNeil, Michael; Dunham_Whitehead, Camilla
2008-02-28
The U.S. Environmental Protection Agency (EPA) influences the market for plumbing fixtures and fittings by encouraging consumers to purchase products that carry the WaterSense label, which certifies those products as performing at low flow rates compared to unlabeled fixtures and fittings. As consumers decide to purchase water-efficient products, water consumption will decline nationwide. Decreased water consumption should prolong the operating life of water and wastewater treatment facilities.This report describes the method used to calculate national water savings attributable to EPA?s WaterSense program. A Microsoft Excel spreadsheet model, the National Water Savings (NWS) analysis model, accompanies this methodology report. Version 1.0more » of the NWS model evaluates indoor residential water consumption. Two additional documents, a Users? Guide to the spreadsheet model and an Impacts Report, accompany the NWS model and this methodology document. Altogether, these four documents represent Phase One of this project. The Users? Guide leads policy makers through the spreadsheet options available for projecting the water savings that result from various policy scenarios. The Impacts Report shows national water savings that will result from differing degrees of market saturation of high-efficiency water-using products.This detailed methodology report describes the NWS analysis model, which examines the effects of WaterSense by tracking the shipments of products that WaterSense has designated as water-efficient. The model estimates market penetration of products that carry the WaterSense label. Market penetration is calculated for both existing and new construction. The NWS model estimates savings based on an accounting analysis of water-using products and of building stock. Estimates of future national water savings will help policy makers further direct the focus of WaterSense and calculate stakeholder impacts from the program.Calculating the total gallons of water the WaterSense program saves nationwide involves integrating two components, or modules, of the NWS model. Module 1 calculates the baseline national water consumption of typical fixtures, fittings, and appliances prior to the program (as described in Section 2.0 of this report). Module 2 develops trends in efficiency for water-using products both in the business-as-usual case and as a result of the program (Section 3.0). The NWS model combines the two modules to calculate total gallons saved by the WaterSense program (Section 4.0). Figure 1 illustrates the modules and the process involved in modeling for the NWS model analysis.The output of the NWS model provides the base case for each end use, as well as a prediction of total residential indoor water consumption during the next two decades. Based on the calculations described in Section 4.0, we can project a timeline of water savings attributable to the WaterSense program. The savings increase each year as the program results in the installation of greater numbers of efficient products, which come to compose more and more of the product stock in households throughout the United States.« less
Study on energy consumption evaluation of mountainous highway based on LCA
NASA Astrophysics Data System (ADS)
Fei, Lunlin; Zhang, Qi; Xie, Yongqing
2017-06-01
For the system to understand the road construction energy consumption process, this paper selects a typical mountainous highway in the south, using the theory and method of Life Cycle Assessment (LCA) to quantitatively study the energy consumption of the whole process of highway raw materials production, construction and operation. The results show that the energy consumption in the raw material production stage is the highest, followed by the highway operation and construction stage. The energy consumption per unit of tunnel engineering, bridge engineering, roadbed engineering and pavement engineering in the construction phase are 2279.00 tce, 1718.07 tce, 542.19 tce and 34.02 tce, and in operational phase, 85.44% of electricity consumption comes from tunnel ventilation and lighting. Therefore, in the bridge and tunnel construction process, we should promote energy-saving innovation of the construction technology and mechanical equipment, and further strengthen the research and development of tunnel ventilation, lighting energy-saving equipment and intelligent control technology, which will help significantly reduce the energy consumption and greenhouse gas emissions of the life cycle of highway.
Influences on Energy Savings of Heavy Trucks Using Cooperative Adaptive Cruise Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lammert, Michael P; McAuliffe, Brian; Lu, Xiao-Yun
An integrated adaptive cruise control (ACC) and cooperative ACC (CACC) was implemented and tested on three heavy-duty tractor-trailer trucks on a closed test track. The first truck was always in ACC mode, and the followers were in CACC mode using wireless vehicle-vehicle communication to augment their radar sensor data to enable safe and accurate vehicle following at short gaps. The fuel consumption for each truck in the CACC string was measured using the SAE J1321 procedure while travelling at 65 mph and loaded to a gross weight of 65,000 lb, demonstrating the effects of: inter-vehicle gaps (ranging from 3.0 smore » or 87 m to 0.14 s or 4 m, covering a much wider range than previously reported tests), cut-in and cut-out maneuvers by other vehicles, speed variations, the use of mismatched vehicles (standard trailers mixed with aerodynamic trailers with boat tails and side skirts), and the presence of a passenger vehicle ahead of the platoon. The results showed that energy savings generally increased in a non-linear fashion as the gap was reduced. The middle truck saved the most fuel at gaps shorter than 12 m and the trailing truck saved the most at longer gaps, while lead truck saved the least at all gaps. The cut-in and cut-out maneuvers had only a marginal effect on fuel consumption even when repeated every two miles. The presence of passenger-vehicle traffic had a measurable impact. The fuel-consumption savings on the curves was less than on the straight sections.« less
Optoelectronic aid for patients with severely restricted visual fields in daylight conditions
NASA Astrophysics Data System (ADS)
Peláez-Coca, María Dolores; Sobrado-Calvo, Paloma; Vargas-Martín, Fernando
2011-11-01
In this study we evaluated the immediate effectiveness of an optoelectronic visual field expander in a sample of subjects with retinitis pigmentosa suffering from a severe peripheral visual field restriction. The aid uses the augmented view concept and provides subjects with visual information from outside their visual field. The tests were carried out in daylight conditions. The optoelectronic aid comprises a FPGA (real-time video processor), a wide-angle mini camera and a transparent see-through head-mounted display. This optoelectronic aid is called SERBA (Sistema Electro-óptico Reconfigurable de Ayuda para Baja Visión). We previously showed that, without compromising residual vision, the SERBA system provides information about objects within an area about three times greater on average than the remaining visual field of the subjects [1]. In this paper we address the effects of the device on mobility under daylight conditions with and without SERBA. The participants were six subjects with retinitis pigmentosa. In this mobility test, better results were obtained when subjects were wearing the SERBA system; specifically, both the number of contacts with low-level obstacles and mobility errors decreased significantly. A longer training period with the device might improve its usefulness.
Daylight coloring for monochrome infrared imagery
NASA Astrophysics Data System (ADS)
Gabura, James
2015-05-01
The effectiveness of infrared imagery in poor visibility situations is well established and the range of applications is expanding as we enter a new era of inexpensive thermal imagers for mobile phones. However there is a problem in that the counterintuitive reflectance characteristics of various common scene elements can cause slowed reaction times and impaired situational awareness-consequences that can be especially detrimental in emergency situations. While multiband infrared sensors can be used, they are inherently more costly. Here we propose a technique for adding a daylight color appearance to single band infrared images, using the normally overlooked property of local image texture. The simple method described here is illustrated with colorized images from the visible red and long wave infrared bands. Our colorizing process not only imparts a natural daylight appearance to infrared images but also enhances the contrast and visibility of otherwise obscure detail. We anticipate that this colorizing method will lead to a better user experience, faster reaction times and improved situational awareness for a growing community of infrared camera users. A natural extension of our process could expand upon its texture discerning feature by adding specialized filters for discriminating specific targets.
Biogeography of time partitioning in mammals.
Bennie, Jonathan J; Duffy, James P; Inger, Richard; Gaston, Kevin J
2014-09-23
Many animals regulate their activity over a 24-h sleep-wake cycle, concentrating their peak periods of activity to coincide with the hours of daylight, darkness, or twilight, or using different periods of light and darkness in more complex ways. These behavioral differences, which are in themselves functional traits, are associated with suites of physiological and morphological adaptations with implications for the ecological roles of species. The biogeography of diel time partitioning is, however, poorly understood. Here, we document basic biogeographic patterns of time partitioning by mammals and ecologically relevant large-scale patterns of natural variation in "illuminated activity time" constrained by temperature, and we determine how well the first of these are predicted by the second. Although the majority of mammals are nocturnal, the distributions of diurnal and crepuscular species richness are strongly associated with the availability of biologically useful daylight and twilight, respectively. Cathemerality is associated with relatively long hours of daylight and twilight in the northern Holarctic region, whereas the proportion of nocturnal species is highest in arid regions and lowest at extreme high altitudes. Although thermal constraints on activity have been identified as key to the distributions of organisms, constraints due to functional adaptation to the light environment are less well studied. Global patterns in diversity are constrained by the availability of the temporal niche; disruption of these constraints by the spread of artificial lighting and anthropogenic climate change, and the potential effects on time partitioning, are likely to be critical influences on species' future distributions.
NASA Astrophysics Data System (ADS)
Dong, J. Y.; Cheng, W.; Ma, C. P.; Xin, L. S.; Tan, Y. T.
2017-06-01
In order to study the issue of rural residential energy consumption in cold regions of China, modeled an architecture prototype based on BIM platform according to the affecting factors of rural residential thermal environment, and imported the virtual model which contains building information into energy analysis tools and chose the appropriate building orientation. By analyzing the energy consumption of the residential buildings with different enclosure structure forms, we designed the optimal energy-saving residence form. There is a certain application value of this method for researching the energy consumption and energy-saving design for the rural residence in cold regions of China.
Alleviating Pressure on Water Resources: A new approach could be attempted
NASA Astrophysics Data System (ADS)
Sun, Shikun; Wang, Yubao; Wang, Feifei; Liu, Jing; Luan, Xiaobo; Li, Xiaolei; Zhou, Tianwa; Wu, Pute
2015-09-01
Water and food safety are two major challenges which the world faces today. Traditional water management focuses on the reduction of water use through improvements in water saving technologies. However, quantitative research is needed to evaluate the effects of changing food consumption patterns on water resources. Here we report the water saving effects of changing diet pattern of the major crops and animal products in mainland China. By using the concepts of water footprint (WF) per weight unit and per calorie unit, provided by 13 primary crop and animal products, the WFs of the 13 agricultural products in each province are compared, and their water/energy conversion efficiencies are analyzed. Then, impacts of different scenarios of changing diet pattern on water consumption were explored. Results show that there are obvious differences between the WF per weight and calorie unit provided by crop and animal products due to the nutritional properties of the agricultural products. Promoting water savings from the food consumption side could give a positive feedback on water consumption. Scenario analysis of adjustments to the diet pattern proves that it is potentially feasible to reach the objective of alleviating stress on water resources while guaranteeing nutritional value of the residents.
Alleviating Pressure on Water Resources: A new approach could be attempted.
Sun, Shikun; Wang, Yubao; Wang, Feifei; Liu, Jing; Luan, Xiaobo; Li, Xiaolei; Zhou, Tianwa; Wu, Pute
2015-09-14
Water and food safety are two major challenges which the world faces today. Traditional water management focuses on the reduction of water use through improvements in water saving technologies. However, quantitative research is needed to evaluate the effects of changing food consumption patterns on water resources. Here we report the water saving effects of changing diet pattern of the major crops and animal products in mainland China. By using the concepts of water footprint (WF) per weight unit and per calorie unit, provided by 13 primary crop and animal products, the WFs of the 13 agricultural products in each province are compared, and their water/energy conversion efficiencies are analyzed. Then, impacts of different scenarios of changing diet pattern on water consumption were explored. Results show that there are obvious differences between the WF per weight and calorie unit provided by crop and animal products due to the nutritional properties of the agricultural products. Promoting water savings from the food consumption side could give a positive feedback on water consumption. Scenario analysis of adjustments to the diet pattern proves that it is potentially feasible to reach the objective of alleviating stress on water resources while guaranteeing nutritional value of the residents.
Alleviating Pressure on Water Resources: A new approach could be attempted
Sun, Shikun; Wang, Yubao; Wang, Feifei; Liu, Jing; Luan, Xiaobo; Li, Xiaolei; Zhou, Tianwa; Wu, Pute
2015-01-01
Water and food safety are two major challenges which the world faces today. Traditional water management focuses on the reduction of water use through improvements in water saving technologies. However, quantitative research is needed to evaluate the effects of changing food consumption patterns on water resources. Here we report the water saving effects of changing diet pattern of the major crops and animal products in mainland China. By using the concepts of water footprint (WF) per weight unit and per calorie unit, provided by 13 primary crop and animal products, the WFs of the 13 agricultural products in each province are compared, and their water/energy conversion efficiencies are analyzed. Then, impacts of different scenarios of changing diet pattern on water consumption were explored. Results show that there are obvious differences between the WF per weight and calorie unit provided by crop and animal products due to the nutritional properties of the agricultural products. Promoting water savings from the food consumption side could give a positive feedback on water consumption. Scenario analysis of adjustments to the diet pattern proves that it is potentially feasible to reach the objective of alleviating stress on water resources while guaranteeing nutritional value of the residents. PMID:26364756
Review of the Application of Green Building and Energy Saving Technology
NASA Astrophysics Data System (ADS)
Tong, Zhineng
2017-12-01
The use of energy-saving technologies in green buildings should run through the entire process of building design, construction and use, enabling green energy-saving technologies to maximize their effectiveness in construction. Realize the sustainable development of green building, reduce energy consumption, reduce people’s interference with the natural environment, suitable for people living in “green” building.
NASA Astrophysics Data System (ADS)
Sokol, Natalia; Martyniuk-Peczek, Justyna
2017-10-01
This paper reports on the partial results of the research aiming to illustrate how an integration of daylight design into an architectural planning process can help designers to create the residential buildings in respect to the environmental issues, solar and illuminance gains, as well as, the residents’ needs and comfort. It describes how changing daylight recommendations affected the design of the block of flats regarding their orientation, the spacing, the forms, and the size of the windows in the four urban residential areas. The results of this study help to determine more precise characterization of daylight indicators useful in architectural planning.
Shi, Xiao-Qing; Li, Xiao-Nuo; Yang, Jian-Xin
2013-01-01
Transportation is the key industry of urban energy consumption and carbon emissions. The transformation of conventional gasoline vehicles to new energy vehicles is an important initiative to realize the goal of developing low-carbon city through energy saving and emissions reduction, while electric vehicles (EV) will play an important role in this transition due to their advantage in energy saving and lower carbon emissions. After reviewing the existing researches on energy saving and emissions reduction of electric vehicles, this paper analyzed the factors affecting carbon emissions reduction. Combining with electric vehicles promotion program in Beijing, the paper analyzed carbon emissions and reduction potential of electric vehicles in six scenarios using the optimized energy consumption related carbon emissions model from the perspective of fuel life cycle. The scenarios included power energy structure, fuel type (energy consumption per 100 km), car type (CO2 emission factor of fuel), urban traffic conditions (speed), coal-power technologies and battery type (weight, energy efficiency). The results showed that the optimized model was able to estimate carbon emissions caused by fuel consumption more reasonably; electric vehicles had an obvious restrictive carbon reduction potential with the fluctuation of 57%-81.2% in the analysis of six influencing factors, while power energy structure and coal-power technologies play decisive roles in life-cycle carbon emissions of electric vehicles with the reduction potential of 78.1% and 81.2%, respectively. Finally, some optimized measures were proposed to reduce transport energy consumption and carbon emissions during electric vehicles promotion including improving energy structure and coal technology, popularizing energy saving technologies and electric vehicles, accelerating the battery R&D and so on. The research provides scientific basis and methods for the policy development for the transition of new energy vehicles in low-carbon transport.
Daylight strategies for architectural studio facilities: the literature review
NASA Astrophysics Data System (ADS)
Othman, Muhammad Anas Bin; Azfahani Ahmad, Nur; Ajis, Azizah Md
2017-05-01
The implementation of daylighting strategies in buildings is a common aspect in architecture. However, due to the availability of inexpensive electricity, natural lighting strategies became insignificant, and been overlooked by designers. With the current concern over rapid increment on electricity cost, many designers now try to revitalized daylighting strategies in buildings. This includes educational buildings. In Malaysian cases, it is a norm that universities; especially during lecture and studio sessions, used artificial lighting throughout the day. Definitely, this is not parallel with the “green” aim made by the Government in the Malaysian Plan. Therefore, this paper aims to explore the impact of daylight strategies for educational studios in universities, by maximising the penetration of natural daylight into the space towards creating a more green-conducive studio. The paper review literature about the types, criteria and benefits of daylight strategies. This paper also presented a pilot study that has been performed in one university in Perak, Malaysia, by selecting architectural studios as the main subject.
An energy-efficient failure detector for vehicular cloud computing.
Liu, Jiaxi; Wu, Zhibo; Dong, Jian; Wu, Jin; Wen, Dongxin
2018-01-01
Failure detectors are one of the fundamental components for maintaining the high availability of vehicular cloud computing. In vehicular cloud computing, lots of RSUs are deployed along the road to improve the connectivity. Many of them are equipped with solar battery due to the unavailability or excess expense of wired electrical power. So it is important to reduce the battery consumption of RSU. However, the existing failure detection algorithms are not designed to save battery consumption RSU. To solve this problem, a new energy-efficient failure detector 2E-FD has been proposed specifically for vehicular cloud computing. 2E-FD does not only provide acceptable failure detection service, but also saves the battery consumption of RSU. Through the comparative experiments, the results show that our failure detector has better performance in terms of speed, accuracy and battery consumption.
An energy-efficient failure detector for vehicular cloud computing
Liu, Jiaxi; Wu, Zhibo; Wu, Jin; Wen, Dongxin
2018-01-01
Failure detectors are one of the fundamental components for maintaining the high availability of vehicular cloud computing. In vehicular cloud computing, lots of RSUs are deployed along the road to improve the connectivity. Many of them are equipped with solar battery due to the unavailability or excess expense of wired electrical power. So it is important to reduce the battery consumption of RSU. However, the existing failure detection algorithms are not designed to save battery consumption RSU. To solve this problem, a new energy-efficient failure detector 2E-FD has been proposed specifically for vehicular cloud computing. 2E-FD does not only provide acceptable failure detection service, but also saves the battery consumption of RSU. Through the comparative experiments, the results show that our failure detector has better performance in terms of speed, accuracy and battery consumption. PMID:29352282
NASA Astrophysics Data System (ADS)
Kang, Donghun; Lee, Jungeon; Jung, Jongpil; Lee, Chul-Hee; Kyung, Chong-Min
2014-09-01
In mobile video systems powered by battery, reducing the encoder's compression energy consumption is critical to prolong its lifetime. Previous Energy-rate-distortion (E-R-D) optimization methods based on a software codec is not suitable for practical mobile camera systems because the energy consumption is too large and encoding rate is too low. In this paper, we propose an E-R-D model for the hardware codec based on the gate-level simulation framework to measure the switching activity and the energy consumption. From the proposed E-R-D model, an energy minimizing algorithm for mobile video camera sensor have been developed with the GOP (Group of Pictures) size and QP(Quantization Parameter) as run-time control variables. Our experimental results show that the proposed algorithm provides up to 31.76% of energy consumption saving while satisfying the rate and distortion constraints.
A fractal comparison of real and Austrian business cycle models
NASA Astrophysics Data System (ADS)
Mulligan, Robert F.
2010-06-01
Rescaled range and power spectral density analysis are applied to examine a diverse set of macromonetary data for fractal character and stochastic dependence. Fractal statistics are used to evaluate two competing models of the business cycle, Austrian business cycle theory and real business cycle theory. Strong evidence is found for antipersistent stochastic dependence in transactions money (M1) and components of the monetary aggregates most directly concerned with transactions, which suggests an activist monetary policy. Savings assets exhibit persistent long memory, as do those monetary aggregates which include savings assets, such as savings money (M2), M2 minus small time deposits, and money of zero maturity (MZM). Virtually all measures of economic activity display antipersistence, and this finding is invariant to whether the measures are adjusted for inflation, including real gross domestic product, real consumption expenditures, real fixed private investment, and labor productivity. This strongly disconfirms real business cycle theory.
Feeding periodicity, diet composition, and food consumption of subyearling rainbow trout in winter
Johnson, James H.; Chalupnicki, Marc; Abbett, Ross
2016-01-01
Although winter is a critically important period for stream salmonids, aspects of the ecology of several species are poorly understood. Consequently, we examined the diel feeding ecology of subyearling rainbow trout (Oncorhynchus mykiss) during winter in a central New York stream. Rainbow trout diet was significantly different during each 4-h interval and also differed from the drift and benthos. Feeding was significantly greater during darkness (i.e. 20:00 h – 04:00 h) than during daylight hours (i.e. 08:00 h – 16:00 h), peaking at 20:00 h. Daily food consumption (1.9 mg) and daily ration (3.4 %) during winter were substantially lower than previously reported for subyearling rainbow trout in the same stream during summer. These findings provide important new insights into the winter feeding ecology of juvenile rainbow trout in streams.
Prediction-Based Energy Saving Mechanism in 3GPP NB-IoT Networks.
Lee, Jinseong; Lee, Jaiyong
2017-09-01
The current expansion of the Internet of things (IoT) demands improved communication platforms that support a wide area with low energy consumption. The 3rd Generation Partnership Project introduced narrowband IoT (NB-IoT) as IoT communication solutions. NB-IoT devices should be available for over 10 years without requiring a battery replacement. Thus, a low energy consumption is essential for the successful deployment of this technology. Given that a high amount of energy is consumed for radio transmission by the power amplifier, reducing the uplink transmission time is key to ensure a long lifespan of an IoT device. In this paper, we propose a prediction-based energy saving mechanism (PBESM) that is focused on enhanced uplink transmission. The mechanism consists of two parts: first, the network architecture that predicts the uplink packet occurrence through a deep packet inspection; second, an algorithm that predicts the processing delay and pre-assigns radio resources to enhance the scheduling request procedure. In this way, our mechanism reduces the number of random accesses and the energy consumed by radio transmission. Simulation results showed that the energy consumption using the proposed PBESM is reduced by up to 34% in comparison with that in the conventional NB-IoT method.
Prediction-Based Energy Saving Mechanism in 3GPP NB-IoT Networks
2017-01-01
The current expansion of the Internet of things (IoT) demands improved communication platforms that support a wide area with low energy consumption. The 3rd Generation Partnership Project introduced narrowband IoT (NB-IoT) as IoT communication solutions. NB-IoT devices should be available for over 10 years without requiring a battery replacement. Thus, a low energy consumption is essential for the successful deployment of this technology. Given that a high amount of energy is consumed for radio transmission by the power amplifier, reducing the uplink transmission time is key to ensure a long lifespan of an IoT device. In this paper, we propose a prediction-based energy saving mechanism (PBESM) that is focused on enhanced uplink transmission. The mechanism consists of two parts: first, the network architecture that predicts the uplink packet occurrence through a deep packet inspection; second, an algorithm that predicts the processing delay and pre-assigns radio resources to enhance the scheduling request procedure. In this way, our mechanism reduces the number of random accesses and the energy consumed by radio transmission. Simulation results showed that the energy consumption using the proposed PBESM is reduced by up to 34% in comparison with that in the conventional NB-IoT method. PMID:28862675
A network coding based routing protocol for underwater sensor networks.
Wu, Huayang; Chen, Min; Guan, Xin
2012-01-01
Due to the particularities of the underwater environment, some negative factors will seriously interfere with data transmission rates, reliability of data communication, communication range, and network throughput and energy consumption of underwater sensor networks (UWSNs). Thus, full consideration of node energy savings, while maintaining a quick, correct and effective data transmission, extending the network life cycle are essential when routing protocols for underwater sensor networks are studied. In this paper, we have proposed a novel routing algorithm for UWSNs. To increase energy consumption efficiency and extend network lifetime, we propose a time-slot based routing algorithm (TSR).We designed a probability balanced mechanism and applied it to TSR. The theory of network coding is introduced to TSBR to meet the requirement of further reducing node energy consumption and extending network lifetime. Hence, time-slot based balanced network coding (TSBNC) comes into being. We evaluated the proposed time-slot based balancing routing algorithm and compared it with other classical underwater routing protocols. The simulation results show that the proposed protocol can reduce the probability of node conflicts, shorten the process of routing construction, balance energy consumption of each node and effectively prolong the network lifetime.
A Network Coding Based Routing Protocol for Underwater Sensor Networks
Wu, Huayang; Chen, Min; Guan, Xin
2012-01-01
Due to the particularities of the underwater environment, some negative factors will seriously interfere with data transmission rates, reliability of data communication, communication range, and network throughput and energy consumption of underwater sensor networks (UWSNs). Thus, full consideration of node energy savings, while maintaining a quick, correct and effective data transmission, extending the network life cycle are essential when routing protocols for underwater sensor networks are studied. In this paper, we have proposed a novel routing algorithm for UWSNs. To increase energy consumption efficiency and extend network lifetime, we propose a time-slot based routing algorithm (TSR).We designed a probability balanced mechanism and applied it to TSR. The theory of network coding is introduced to TSBR to meet the requirement of further reducing node energy consumption and extending network lifetime. Hence, time-slot based balanced network coding (TSBNC) comes into being. We evaluated the proposed time-slot based balancing routing algorithm and compared it with other classical underwater routing protocols. The simulation results show that the proposed protocol can reduce the probability of node conflicts, shorten the process of routing construction, balance energy consumption of each node and effectively prolong the network lifetime. PMID:22666045
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Lei; Holden, Jacob; Gonder, Jeff
New technologies, such as connected and automated vehicles, have attracted more and more researchers for improving the energy efficiency and environmental impact of current transportation systems. The green routing strategy instructs a vehicle to select the most fuel-efficient route before the vehicle departs. It benefits the current transportation system with fuel saving opportunity through identifying the greenest route. This paper introduces an evaluation framework for estimating benefits of green routing based on large-scale, real-world travel data. The framework has the capability to quantify fuel savings by estimating the fuel consumption of actual routes and comparing to routes procured by navigationmore » systems. A route-based fuel consumption estimation model, considering road traffic conditions, functional class, and road grade is proposed and used in the framework. An experiment using a large-scale data set from the California Household Travel Survey global positioning system trajectory data base indicates that 31% of actual routes have fuel savings potential with a cumulative estimated fuel savings of 12%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Lei; Holden, Jacob; Gonder, Jeffrey D
New technologies, such as connected and automated vehicles, have attracted more and more researchers for improving the energy efficiency and environmental impact of current transportation systems. The green routing strategy instructs a vehicle to select the most fuel-efficient route before the vehicle departs. It benefits the current transportation system with fuel saving opportunity through identifying the greenest route. This paper introduces an evaluation framework for estimating benefits of green routing based on large-scale, real-world travel data. The framework has the capability to quantify fuel savings by estimating the fuel consumption of actual routes and comparing to routes procured by navigationmore » systems. A route-based fuel consumption estimation model, considering road traffic conditions, functional class, and road grade is proposed and used in the framework. An experiment using a large-scale data set from the California Household Travel Survey global positioning system trajectory data base indicates that 31% of actual routes have fuel savings potential with a cumulative estimated fuel savings of 12%.« less
Energy Efficient Operation of Ammonia Refrigeration Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohammed, Abdul Qayyum; Wenning, Thomas J; Sever, Franc
Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their size and complexity. This paper develops a model for simulating single-stage ammonia refrigeration systems, describes common energy saving opportunities, and uses the model to quantify those opportunities. The simulation model uses data that are typically available during site visits to ammonia refrigeration plants and can be calibrated to actual consumption and performance data if available. Annual electricity consumption for a base-case ammonia refrigeration system is simulated. The model is then used to quantify energy savings for six specific energy efficiency opportunities; reduce refrigeration load, increase suction pressure, employmore » dual suction, decrease minimum head pressure set-point, increase evaporative condenser capacity, and reclaim heat. Methods and considerations for achieving each saving opportunity are discussed. The model captures synergistic effects that result when more than one component or parameter is changed. This methodology represents an effective method to model and quantify common energy saving opportunities in ammonia refrigeration systems. The results indicate the range of savings that might be expected from common energy efficiency opportunities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mittal, Sparsh; Zhang, Zhao; Vetter, Jeffrey S
Recent trends of CMOS scaling and use of large last level caches (LLCs) have led to significant increase in the leakage energy consumption of LLCs and hence, managing their energy consumption has become extremely important in modern processor design. The conventional cache energy saving techniques require offline profiling or provide only coarse granularity of cache allocation. We present FlexiWay, a cache energy saving technique which uses dynamic cache reconfiguration. FlexiWay logically divides the cache sets into multiple (e.g. 16) modules and dynamically turns off suitable and possibly different number of cache ways in each module. FlexiWay has very small implementationmore » overhead and it provides fine-grain cache allocation even with caches of typical associativity, e.g. an 8-way cache. Microarchitectural simulations have been performed using an x86-64 simulator and workloads from SPEC2006 suite. Also, FlexiWay has been compared with two conventional energy saving techniques. The results show that FlexiWay provides largest energy saving and incurs only small loss in performance. For single, dual and quad core systems, the average energy saving using FlexiWay are 26.2%, 25.7% and 22.4%, respectively.« less
Data analytics for simplifying thermal efficiency planning in cities.
Abdolhosseini Qomi, Mohammad Javad; Noshadravan, Arash; Sobstyl, Jake M; Toole, Jameson; Ferreira, Joseph; Pellenq, Roland J-M; Ulm, Franz-Josef; Gonzalez, Marta C
2016-04-01
More than 44% of building energy consumption in the USA is used for space heating and cooling, and this accounts for 20% of national CO2emissions. This prompts the need to identify among the 130 million households in the USA those with the greatest energy-saving potential and the associated costs of the path to reach that goal. Whereas current solutions address this problem by analysing each building in detail, we herein reduce the dimensionality of the problem by simplifying the calculations of energy losses in buildings. We present a novel inference method that can be used via a ranking algorithm that allows us to estimate the potential energy saving for heating purposes. To that end, we only need consumption from records of gas bills integrated with a building's footprint. The method entails a statistical screening of the intricate interplay between weather, infrastructural and residents' choice variables to determine building gas consumption and potential savings at a city scale. We derive a general statistical pattern of consumption in an urban settlement, reducing it to a set of the most influential buildings' parameters that operate locally. By way of example, the implications are explored using records of a set of (N= 6200) buildings in Cambridge, MA, USA, which indicate that retrofitting only 16% of buildings entails a 40% reduction in gas consumption of the whole building stock. We find that the inferred heat loss rate of buildings exhibits a power-law data distribution akin to Zipf's law, which provides a means to map an optimum path for gas savings per retrofit at a city scale. These findings have implications for improving the thermal efficiency of cities' building stock, as outlined by current policy efforts seeking to reduce home heating and cooling energy consumption and lower associated greenhouse gas emissions. © 2016 The Author(s).
Energy monitoring based on human activity in the workplace
NASA Astrophysics Data System (ADS)
Mustafa, N. H.; Husain, M. N.; Abd Aziz, M. Z. A.; Othman, M. A.; Malek, F.
2014-04-01
Human behavior is the most important factor in order to manage energy usage. Nowadays, smart house technology offers a better quality of life by introducing automated appliance control and assistive services. However, human behaviors will contribute to the efficiency of the system. This paper will focus on monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior atb the workplace. Then, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy in efficient ways based on human behaviours. This scenario will lead to the positive impact in order to achieve the energy saving in the building and support the green environment.
Moonlight project promotes energy-saving technology
NASA Astrophysics Data System (ADS)
Ishihara, A.
1986-01-01
In promoting energy saving, development of energy conservation technologies aimed at raising energy efficiency in the fields of energy conversion, its transportation, its storage, and its consumption is considered, along with enactment of legal actions urging rational use of energies and implementation of an enlightenment campaign for energy conservation to play a crucial role. Under the Moonlight Project, technical development is at present being centered around the following six pillars: (1) large scale energy saving technology; (2) pioneering and fundamental energy saving technology; (3) international cooperative research project; (4) research and survey of energy saving technology; (5) energy saving technology development by private industry; and (6) promotion of energy saving through standardization. Heat pumps, magnetohydrodynamic generators and fuel cells are discussed.
Kim, Junbeum; Xu, Ming; Kahhat, Ramzy; Allenby, Braden; Williams, Eric
2009-01-01
We attempted to design and assess an example of a sustainable networked delivery (SND) system: a hybrid business-to-consumer book delivery system. This system is intended to reduce costs, achieve significant reductions in energy consumption, and reduce environmental emissions of critical local pollutants and greenhouse gases. The energy consumption and concomitant emissions of this delivery system compared with existing alternative delivery systems were estimated. We found that regarding energy consumption, an emerging hybrid delivery system which is a sustainable networked delivery system (SND) would consume 47 and 7 times less than the traditional networked delivery system (TND) and e-commerce networked delivery system (END). Regarding concomitant emissions, in the case of CO2, the SND system produced 32 and 7 times fewer emissions than the TND and END systems. Also the SND system offer meaningful economic benefit such as the costs of delivery and packaging, to the online retailer, grocery, and consumer. Our research results show that the SND system has a lot of possibilities to save local transportation energy consumption and delivery costs, and reduce environmental emissions in delivery system.
Scheduling for energy and reliability management on multiprocessor real-time systems
NASA Astrophysics Data System (ADS)
Qi, Xuan
Scheduling algorithms for multiprocessor real-time systems have been studied for years with many well-recognized algorithms proposed. However, it is still an evolving research area and many problems remain open due to their intrinsic complexities. With the emergence of multicore processors, it is necessary to re-investigate the scheduling problems and design/develop efficient algorithms for better system utilization, low scheduling overhead, high energy efficiency, and better system reliability. Focusing cluster schedulings with optimal global schedulers, we study the utilization bound and scheduling overhead for a class of cluster-optimal schedulers. Then, taking energy/power consumption into consideration, we developed energy-efficient scheduling algorithms for real-time systems, especially for the proliferating embedded systems with limited energy budget. As the commonly deployed energy-saving technique (e.g. dynamic voltage frequency scaling (DVFS)) will significantly affect system reliability, we study schedulers that have intelligent mechanisms to recuperate system reliability to satisfy the quality assurance requirements. Extensive simulation is conducted to evaluate the performance of the proposed algorithms on reduction of scheduling overhead, energy saving, and reliability improvement. The simulation results show that the proposed reliability-aware power management schemes could preserve the system reliability while still achieving substantial energy saving.
Methods for assessing the energy-saving efficiency of industrial symbiosis in industrial parks.
Li, Wenfeng; Cui, Zhaojie; Han, Feng
2015-01-01
The available energy resources are being depleted worldwide. Industrial symbiosis (IS) provides a promising approach for increasing the efficiency of energy utilization, with numerous studies reporting the superiority of this technology. However, studies quantifying the energy-saving efficiency of IS remain insufficient. This paper proposes an index system for the quantitative evaluation of the energy-saving efficiency of IS. Both energy-saving and financial indexes were selected, the former include the IS energy-saving index, the contribution rate of energy saved through IS, fractional energy savings, and cut rate of energy consumption per total output value; and the latter include the IS investment payback period, IS input-output ratio, net present value (NPV), and internal rate of return (IRR) of IS. The proposed methods were applied to a case study on the XF Industrial Park (XF IP), in the city of Liaocheng in Shandong Province of China. Three energy-saving channels using IS were found in the XF IP: (a) utilizing the energy of high-temperature materials among industrial processes, (b) recovering waste heat and steam between different processes, and (c) saving energy by sharing infrastructures. The results showed that the energy efficiency index of IS was 0.326, accounting for 34.6% of the comprehensive energy-saving index in 2011, and the fractional energy-savings were 12.42%. The index of energy consumption per total industrial output value varied from 90.9 tce/MRMB to 51.6 tce/MRMB. Thus, the cut rate of energy consumption per total industrial output value was 43.42%. The average values of the IS input-output ratio was 406.2 RMB/tce, 57.2% lower than the price of standard coal. Static investment payback period in the XF IP was 8.5 months, indicating that the XF IP began to earn profit 8.5 months after the construction of all IS modes. The NVP and IRR of each IS mode in the XF IP were greater than zero, with average values equal to 1,789.96 MRMB and 140.96%, respectively. The computation result for each indicator revealed that IS could lead to the use of energy with high efficiency and lighten the financial burden of enterprises in the XF IP. And the proposed index system may help IPs and EIPs to make strategic decisions when designing IS modes.
Impact of Sustainable Cool Roof Technology on Building Energy Consumption
NASA Astrophysics Data System (ADS)
Vuppuluri, Prem Kiran
Highly reflective roofing systems have been analyzed over several decades to evaluate their ability to meet sustainability goals, including reducing building energy consumption and mitigating the urban heat island. Studies have isolated and evaluated the effects of climate, surface reflectivity, and roof insulation on energy savings, thermal load mitigation and also ameliorating the urban heat island. Other sustainable roofing systems, like green-roofs and solar panels have been similarly evaluated. The motivation for the present study is twofold: the first goal is to present a method for simultaneous evaluation and inter-comparison of multiple roofing systems, and the second goal is to quantitatively evaluate the realized heating and cooling energy savings associated with a white roof system compared to the reduction in roof-top heat flux. To address the first research goal a field experiment was conducted at the International Harvester Building located in Portland, OR. Thermal data was collected for a white roof, vegetated roof, and a solar panel shaded vegetated roof, and the heat flux through these roofing systems was compared against a control patch of conventional dark roof membrane. The second research goal was accomplished using a building energy simulation program to determine the impact of roof area and roof insulation on the savings from a white roof, in both Portland and Phoenix. The ratio of cooling energy savings to roof heat flux reduction from replacing a dark roof with a white roof was 1:4 for the month of July, and 1:5 annually in Portland. The COP of the associated chillers ranges from 2.8-4.2, indicating that the ratio of cooling energy savings to heat flux reduction is not accounted for solely by the COP of the chillers. The results of the building simulation indicate that based on energy savings alone, white roofs are not an optimal choice for Portland. The benefits associated with cooling energy savings relative to a black roof are offset by the winter-time penalty, and the net benefit from adopting white roof technology in Portland is small. That said, there are other potential benefits of white roofing such as impact on urban heat islands and roof life that must also be considered.
Daylighting Concepts for University Libraries and Their Influences on Users' Satisfaction
ERIC Educational Resources Information Center
Kilic, Didem Kan; Hasirci, Deniz
2011-01-01
Daylighting, a controlled architectural tool that influences users' perception and behavior, in university libraries and their influences on users' preference and satisfaction was examined in this study. The effects of daylighting in coordination with visual comfort, on university library users were measured in relation to four environmental…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Yasin; Khare, Vaibhav Rai; Mathur, Jyotirmay
The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building usingmore » a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.« less
Analysis on Zero Energy Consumption Strategy for Office Buildings Lighting in Lianyungang Area
NASA Astrophysics Data System (ADS)
Wu, Dongmei
2018-01-01
In recent years, the energy-saving environmental protection has aroused the people’s high concern, and set off a new application practice in China. By analyzing the advantages of the illumination condition in Lianyungang area and combining the content and form of office space, the author puts forward a series of ways and means of energy saving in office building lighting, in order to provide a way for reference to the goal of building Zero energy consumption in the office space environment under the background of green architecture.
Fabrication and characterization of Aerogel-Polydimethyl siloxane (PDMS) Insulation Film
NASA Astrophysics Data System (ADS)
Noh, Yeoung ah; Song, Sinae; Taik Kim, Hee
2018-03-01
The building has a large impact on the space heating demand and the indoor environment is affected by climate or daylight. Hence, silica aerogel has generally used as a film to reduce the coefficient of the window in the building. Silica aerogel is a suitable material to apply for insulation material with lower thermal conductivity than that of air to save interior energy. However expensive precursor and drying process were the main issue of the silica aerogel synthesis and practical usage. We attempt to fabricate aerogel insulation film for energy saving through the economic process under ambient pressure. Silica aerogel was synthesized from rice husk ash, which was an agricultural waste to be able to recycle. Taguchi design was used to optimize the parameters (amount of rice husk ash, pH, aging time) controlling the surface area of silica aerogel. The silica aerogel is prepared by sol-gel processing through acidic treatment and aging. The silica aerogel was obtained by modification of silica hydrogel surface and dry at ambient pressure. Finally, aerogel film was respectively fabricated by the different content of aerogel in polydimethylsiloxane (PDMS). Silica aerogel obtained 21 – 24nm average particle size was analyzed by SEM and silica aerogel with high surface area (832.26 m2/g), pore size ( 3.30nm ) was characterized by BET. Then silica Aerogel – PDMS insulation film with thermal conductivity (0.002 W/mK) was analyzed by thermal wave system. The study demonstrates an eco-friendly and low-cost route toward silica – PDMS insulation film with low thermal conductivity (0.002 W/mK).
NASA Astrophysics Data System (ADS)
Darghouth, Naim Richard
Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing three types of retail rates (a flat rate, a time-of-use rate, and real-time pricing) from these wholesale price profiles, I examine bill savings from PV generation for the ten wholesale market scenarios under net metering and an alternative to net metering where hourly excess PV generation is compensated at the wholesale price. Most generally, I challenge the common assertion that PV compensation is likely to stay constant (or rise) due to constant (or rising) retail rates, and find that future electricity market scenarios can drive substantial changes in residential retail rates and that these changes, in concert with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV.
Prospects for reducing the processing cost of lithium ion batteries
Wood III, David L.; Li, Jianlin; Daniel, Claus
2014-11-06
A detailed processing cost breakdown is given for lithium-ion battery (LIB) electrodes, which focuses on: elimination of toxic, costly N-methylpyrrolidone (NMP) dispersion chemistry; doubling the thicknesses of the anode and cathode to raise energy density; and, reduction of the anode electrolyte wetting and SEI-layer formation time. These processing cost reduction technologies generically adaptable to any anode or cathode cell chemistry and are being implemented at ORNL. This paper shows step by step how these cost savings can be realized in existing or new LIB manufacturing plants using a baseline case of thin (power) electrodes produced with NMP processing and amore » standard 10-14-day wetting and formation process. In particular, it is shown that aqueous electrode processing can cut the electrode processing cost and energy consumption by an order of magnitude. Doubling the thickness of the electrodes allows for using half of the inactive current collectors and separators, contributing even further to the processing cost savings. Finally wetting and SEI-layer formation cost savings are discussed in the context of a protocol with significantly reduced time. These three benefits collectively offer the possibility of reducing LIB pack cost from $502.8 kWh-1-usable to $370.3 kWh-1-usable, a savings of $132.5/kWh (or 26.4%).« less
Gellerfors, Mikael; Svensén, Christer; Linde, Joacim; Lossius, Hans Morten; Gryth, Dan
2015-09-01
Securing the airway by endotracheal intubation (ETI) is a key issue in prehospital critical care. Night vision goggles (NVG) are used by personnel operating in low-light environments. We examined the feasibility of an anesthesiologist performed ETI using NVG in a helicopter setting. Twelve anesthesiologists performed ETI on a manikin in an emergency room (ER) setting and two helicopter settings, with randomization to either rotary wing daylight (RW-D) or rotary wing in total darkness using binocular NVG (RW-NVG). Primary endpoint was intubation time. Secondary endpoints included success rate, Cormack-Lehane (CL) score, and subjective difficulty according to the Visual Analoge Scale (VAS). The median intubation time was shorter for the RW-D compared to the RW-NVG setting (16.5 seconds vs. 30.0 seconds; p = 0,03). We found no difference in median intubation time for the ER and RW-D settings (16.8 seconds vs. 16.5 seconds; p = 0.91). For all scenarios, success rate was 100%. CL and VAS varied between the ER setting (CL 1.8, VAS 2.8), RW-D setting (CL 2.0, VAS 3.0), and RW-NVG setting (CL 3.0, VAS 6.5). This study suggests that anesthesiologists successfully and quickly can perform ETI in a helicopter setting both in daylight and in darkness using binocular NVG, but with shorter intubation times in daylight. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
Hogewoning, Sander W; Douwstra, Peter; Trouwborst, Govert; van Ieperen, Wim; Harbinson, Jeremy
2010-03-01
Plant responses to the light spectrum under which plants are grown affect their developmental characteristics in a complicated manner. Lamps widely used to provide growth irradiance emit spectra which are very different from natural daylight spectra. Whereas specific responses of plants to a spectrum differing from natural daylight may sometimes be predictable, the overall plant response is generally difficult to predict due to the complicated interaction of the many different responses. So far studies on plant responses to spectra either use no daylight control or, if a natural daylight control is used, it will fluctuate in intensity and spectrum. An artificial solar (AS) spectrum which closely resembles a sunlight spectrum has been engineered, and growth, morphogenesis, and photosynthetic characteristics of cucumber plants grown for 13 d under this spectrum have been compared with their performance under fluorescent tubes (FTs) and a high pressure sodium lamp (HPS). The total dry weight of the AS-grown plants was 2.3 and 1.6 times greater than that of the FT and HPS plants, respectively, and the height of the AS plants was 4-5 times greater. This striking difference appeared to be related to a more efficient light interception by the AS plants, characterized by longer petioles, a greater leaf unfolding rate, and a lower investment in leaf mass relative to leaf area. Photosynthesis per leaf area was not greater for the AS plants. The extreme differences in plant response to the AS spectrum compared with the widely used protected cultivation light sources tested highlights the importance of a more natural spectrum, such as the AS spectrum, if the aim is to produce plants representative of field conditions.
NASA Astrophysics Data System (ADS)
Jiang, Yingni
2018-03-01
Due to the high energy consumption of communication, energy saving of data centers must be enforced. But the lack of evaluation mechanisms has restrained the process on energy saving construction of data centers. In this paper, energy saving evaluation index system of data centers was constructed on the basis of clarifying the influence factors. Based on the evaluation index system, analytical hierarchy process was used to determine the weights of the evaluation indexes. Subsequently, a three-grade fuzzy comprehensive evaluation model was constructed to evaluate the energy saving system of data centers.
Calibrated energy simulations of potential energy savings in actual retail buildings
NASA Astrophysics Data System (ADS)
Alhafi, Zuhaira
Retail stores are commercial buildings with high energy consumption due to their typically large volumes and long hours of operation. This dissertation assesses heating, ventilating and air conditioning saving strategies based on energy simulations with input parameters from actual retail buildings. The dissertation hypothesis is that "Retail store buildings will save a significant amount of energy by (1) modifying ventilation rates, and/or (2) resetting set point temperatures. These strategies have shown to be beneficial in previous studies. As presented in the literature review, potential energy savings ranged from 0.5% to 30% without compromising indoor thermal comfort and indoor air quality. The retail store buildings can be ventilated at rates significantly lower than rates called for in the ASHRAE Standard 62.1-2010 while maintaining acceptable indoor air quality. Therefore, two dissertation objectives are addressed: (1) Investigate opportunities to reduce ventilation rates that do not compromise indoor air quality in retail stores located in Central Pennsylvania, (2) Investigate opportunities to increase (in summer) and decrease (in winter) set point temperatures that do not compromise thermal comfort. This study conducted experimental measurements of ventilation rates required to maintain acceptable air quality and indoor environmental conditions requirements for two retail stores using ASHRAE Standard 62.1_2012. More specifically, among other parameters, occupancy density, indoor and outdoor pollutant concentrations, and indoor temperatures were measured continuously for one week interval. One of these retail stores were tested four times for a yearlong time period. Pollutants monitored were formaldehyde, carbon dioxide, particle size distributions and concentrations, as well as total volatile organic compounds. As a part of the base protocol, the number of occupants in each store was hourly counted during the test, and the results reveal that the occupant densities were approximately 20% to 30% of that called by ASHRAE 62.1. Formaldehyde was the most important contaminant of concern in retail stores investigated. Both stores exceeded the most conservative health guideline for formaldehyde (OEHHA TWA REL = 7.3 ppb). This study found that source removal and reducing the emission rate, as demonstrated in retail stores sampled in this study, is a viable strategy to meet the health guideline. Total volatile compound were present in retail stores at low concentrations well below health guidelines suggested by Molhave (1700microg /m 2) and Bridges (1000 microg /m2). Based on these results and through mass--balance modeling, different ventilation rate reduction scenarios were proposed, and for these scenarios the differences in energy consumption were estimated. Findings of all phases of this desertion have contributed to understanding (a) the trade-off between energy savings and ventilation rates that do not compromise indoor air quality, and (b) the trade-off between energy savings and resets of indoor air temperature that do not compromise thermal comfort. Two models for retail stores were built and calibrated and validated against actual utility bills. Energy simulation results indicated that by lowering the ventilation rates from measured and minimum references would reduce natural gas energy use by estimated values of 6% to 19%. Also, this study found that the electrical cooling energy consumption was not significantly sensitive to different ventilation rates. However, increasing indoor air temperature by 3°C in summer had a significant effect on the energy savings. In winter, both energy savings strategies, ventilation reduction and decrease in set points, had a significant effect on natural gas consumption. Specially, when the indoor air temperature 21°C was decreased to 19.4°C with the same amount of ventilation rate of Molhaves guideline for both cases. Interestingly, the temperature of 23.8°C (75°F), which is the lowest value of ASHRAE 55 thermal comfort for sedentary people (cashiers) and the highest value for thermal comfort adjustments due to activity level (customers and workers) that are calculated by using empirical equation, was the optimum temperature for sedentary and active people in Retail store buildings.
ERIC Educational Resources Information Center
American School and University, 1981
1981-01-01
Schools in Wilton (Connecticut) cut electric consumption 39 percent by replacing existing lamps with new types of energy saving lamps. Fuel oil consumption dropped 53 percent largely through attention paid to the operation of boilers and oil burners. (Author/MLF)
Assessment of the Energy Impacts of Improving Highway-Infrastructure Materials
DOT National Transportation Integrated Search
1995-04-01
Argonne National Laboratory has conducted a study to ascertain the relative importance of improved highway materials compared to vehicle energy consumption on U.S. energy consumption. Energy savings through an improved highway infrastructure can occu...
Moving into the Light: The AEOS Telescope in the Daytime Operating Environment
NASA Astrophysics Data System (ADS)
Mayo, J.
Abstract for Coming into the Light: The AEOS Telescope in the Daytime Operating Environment” Interest in daylight operation for the AEOS 3.67-m Telescope first surfaced during the preparation of the AEOS specification documentation in 1991. The author and Lt Rich Elder prepared, edited and combined requirements inputs from AFRL technical staff to create the final RFP document. In this released specification, AEOS daylight performance was limited to best effort, although provisions for adding secondary mirror sky light baffling were to be provided. In 1993, during the AEOS construction phase, AFRL requested that the author prepare a report on special considerations for operating AEOS in the solar illuminated daytime environment. This report was published and briefed to AFRL and Space Command at that time. Interest in this topic at AMOS was rekindled in 2007 by Dr Joe Janni and Lt Col Scott Hunt. The author updated his 1993 report and in June 2007 presented AEOS 1993 Daylight Operation Study Revisited” at AMOS. Subsequently, Dr Stacie Williams spearheaded additional work in this critical technical area. Recent efforts at Tau Technologies LLC have focused on external AEOS telescope baffling and shielding options assessment, solar irradiation effects on optical components, especially the primary mirror, and on modeling the solar illumination on the entire telescope during daylight operation. Solid Works and Illustrator simulation models have been developed and exercised.
The possible impact of an alcohol welfare surcharge on consumption of alcoholic beverages in Taiwan
2013-01-01
Background The abuse of alcoholic beverages leads to numerous negative consequences in Taiwan, as around the world. Alcohol abuse not only contributes to cardiovascular disease, hypertension, diabetes and cancer, but it is also an underlying cause of many other serious problems, such as traffic accidents, lost productivity, and domestic violence. International leaders in health policy are increasingly using taxation as an effective tool with which to lower alcohol consumption. In this study, we assessed how consumption patterns in Taiwan would be affected by levying a welfare surcharge on alcoholic beverages of 20%, 40% or 60% in accordance with the current excise tax. We also assessed the medical savings Taiwan would experience if consumption of alcoholic beverages were to decrease and how much additional revenue a welfare surcharge would generate. Methods We estimated the elasticity of four types of alcoholic beverages (beer, wine, whisky and brandy) using the Central Bureau of Statistics (CBS) Demand Model. Specifically, we estimated alcohol’s price elasticity by analyzing the sales prices and time statistics of these products from 1974 to 2009. Results Alcoholic beverages in Taiwan have the following price elasticities: beer (−0.820), wine (−0.955), whisky (−0.587), brandy (−0.958). A welfare surcharge tax of 40% in accordance with the excise tax would decrease overall consumption of beer, wine, whisky and brandy between 16.24% and 16.42%. It would also generate New Taiwan Dollar (NT$) revenues of 5.782 billion to 5.993 billion. Savings in medical costs would range from NT$871.07 million to NT$897.46 million annually. Conclusions A social and welfare surcharge of 40% on alcoholic beverages in Taiwan would successfully lower consumption rates, decrease medical costs, and generate revenue that could be used to educate consumers and further decrease consumption rates. Consequently, we strongly recommend that such a tax be imposed in Taiwan. PMID:24010885
The possible impact of an alcohol welfare surcharge on consumption of alcoholic beverages in Taiwan.
Yeh, Chun-Yuan; Ho, Li-Ming; Lee, Jie-Min; Hwang, Jhe-Yo
2013-09-08
The abuse of alcoholic beverages leads to numerous negative consequences in Taiwan, as around the world. Alcohol abuse not only contributes to cardiovascular disease, hypertension, diabetes and cancer, but it is also an underlying cause of many other serious problems, such as traffic accidents, lost productivity, and domestic violence. International leaders in health policy are increasingly using taxation as an effective tool with which to lower alcohol consumption. In this study, we assessed how consumption patterns in Taiwan would be affected by levying a welfare surcharge on alcoholic beverages of 20%, 40% or 60% in accordance with the current excise tax. We also assessed the medical savings Taiwan would experience if consumption of alcoholic beverages were to decrease and how much additional revenue a welfare surcharge would generate. We estimated the elasticity of four types of alcoholic beverages (beer, wine, whisky and brandy) using the Central Bureau of Statistics (CBS) Demand Model. Specifically, we estimated alcohol's price elasticity by analyzing the sales prices and time statistics of these products from 1974 to 2009. Alcoholic beverages in Taiwan have the following price elasticities: beer (-0.820), wine (-0.955), whisky (-0.587), brandy (-0.958). A welfare surcharge tax of 40% in accordance with the excise tax would decrease overall consumption of beer, wine, whisky and brandy between 16.24% and 16.42%. It would also generate New Taiwan Dollar (NT$) revenues of 5.782 billion to 5.993 billion. Savings in medical costs would range from NT$871.07 million to NT$897.46 million annually. A social and welfare surcharge of 40% on alcoholic beverages in Taiwan would successfully lower consumption rates, decrease medical costs, and generate revenue that could be used to educate consumers and further decrease consumption rates. Consequently, we strongly recommend that such a tax be imposed in Taiwan.
Smart energy management system
NASA Astrophysics Data System (ADS)
Desai, Aniruddha; Singh, Jugdutt
2010-04-01
Peak and average energy usage in domestic and industrial environments is growing rapidly and absence of detailed energy consumption metrics is making systematic reduction of energy usage very difficult. Smart energy management system aims at providing a cost-effective solution for managing soaring energy consumption and its impact on green house gas emissions and climate change. The solution is based on seamless integration of existing wired and wireless communication technologies combined with smart context-aware software which offers a complete solution for automation of energy measurement and device control. The persuasive software presents users with easy-to-assimilate visual cues identifying problem areas and time periods and encourages a behavioural change to conserve energy. The system allows analysis of real-time/statistical consumption data with the ability to drill down into detailed analysis of power consumption, CO2 emissions and cost. The system generates intelligent projections and suggests potential methods (e.g. reducing standby, tuning heating/cooling temperature, etc.) of reducing energy consumption. The user interface is accessible using web enabled devices such as PDAs, PCs, etc. or using SMS, email, and instant messaging. Successful real-world trial of the system has demonstrated the potential to save 20 to 30% energy consumption on an average. Low cost of deployment and the ability to easily manage consumption from various web enabled devices offers gives this system a high penetration and impact capability offering a sustainable solution to act on climate change today.
Light Moves: Integrating Daylight into School Design from the Start
ERIC Educational Resources Information Center
Brossy de Dios, Eric; Rogic, Tinka; Vaughn, Wendell
2010-01-01
Numerous studies have demonstrated the benefits of daylight on the learning environment. Enhanced student performance and mood, increased teacher and student attendance, reduced energy costs, as well as a positive effect on the environment are some of the improvements seen in school buildings that use well-planned daylighting concepts. Looking at…
Effective Energy Simulation and Optimal Design of Side-lit Buildings with Venetian Blinds
NASA Astrophysics Data System (ADS)
Cheng, Tian
Venetian blinds are popularly used in buildings to control the amount of incoming daylight for improving visual comfort and reducing heat gains in air-conditioning systems. Studies have shown that the proper design and operation of window systems could result in significant energy savings in both lighting and cooling. However, there is no convenient computer tool that allows effective and efficient optimization of the envelope of side-lit buildings with blinds now. Three computer tools, Adeline, DOE2 and EnergyPlus widely used for the above-mentioned purpose have been experimentally examined in this study. Results indicate that the two former tools give unacceptable accuracy due to unrealistic assumptions adopted while the last one may generate large errors in certain conditions. Moreover, current computer tools have to conduct hourly energy simulations, which are not necessary for life-cycle energy analysis and optimal design, to provide annual cooling loads. This is not computationally efficient, particularly not suitable for optimal designing a building at initial stage because the impacts of many design variations and optional features have to be evaluated. A methodology is therefore developed for efficient and effective thermal and daylighting simulations and optimal design of buildings with blinds. Based on geometric optics and radiosity method, a mathematical model is developed to reasonably simulate the daylighting behaviors of venetian blinds. Indoor illuminance at any reference point can be directly and efficiently computed. They have been validated with both experiments and simulations with Radiance. Validation results show that indoor illuminances computed by the new models agree well with the measured data, and the accuracy provided by them is equivalent to that of Radiance. The computational efficiency of the new models is much higher than that of Radiance as well as EnergyPlus. Two new methods are developed for the thermal simulation of buildings. A fast Fourier transform (FFT) method is presented to avoid the root-searching process in the inverse Laplace transform of multilayered walls. Generalized explicit FFT formulae for calculating the discrete Fourier transform (DFT) are developed for the first time. They can largely facilitate the implementation of FFT. The new method also provides a basis for generating the symbolic response factors. Validation simulations show that it can generate the response factors as accurate as the analytical solutions. The second method is for direct estimation of annual or seasonal cooling loads without the need for tedious hourly energy simulations. It is validated by hourly simulation results with DOE2. Then symbolic long-term cooling load can be created by combining the two methods with thermal network analysis. The symbolic long-term cooling load can keep the design parameters of interest as symbols, which is particularly useful for the optimal design and sensitivity analysis. The methodology is applied to an office building in Hong Kong for the optimal design of building envelope. Design variables such as window-to-wall ratio, building orientation, and glazing optical and thermal properties are included in the study. Results show that the selected design values could significantly impact the energy performance of windows, and the optimal design of side-lit buildings could greatly enhance energy savings. The application example also demonstrates that the developed methodology significantly facilitates the optimal building design and sensitivity analysis, and leads to high computational efficiency.
Convenience food products. Drivers for consumption.
Brunner, Thomas A; van der Horst, Klazine; Siegrist, Michael
2010-12-01
Convenience is one of the big trends in the food business. The demand for convenience food products is steadily increasing; therefore, understanding convenience food consumption is an important issue. Despite being vital properties of convenience food, saving time and effort have not been very successful constructs for predicting convenience food consumption. To examine a wide range of possible drivers for convenience food consumption, the present study uses a convenience food frequency questionnaire that asks about consumption behavior. A paper-and-pencil questionnaire was sent out to a representative sample of people in German-speaking Switzerland and yielded N = 918 complete datasets from persons mainly responsible for buying and preparing food in the household. The various convenience food products could be categorized into four groups, which we labeled as highly processed food items, moderately processed food items, single components, and salads. Fifteen drivers were found to have a significant impact either on total convenience consumption or on one of the identified categories. Strong predictors were age, concern about naturalness, nutrition knowledge, and cooking skills. Copyright © 2010 Elsevier Ltd. All rights reserved.
Energy-saving framework for passive optical networks with ONU sleep/doze mode.
Van, Dung Pham; Valcarenghi, Luca; Dias, Maluge Pubuduni Imali; Kondepu, Koteswararao; Castoldi, Piero; Wong, Elaine
2015-02-09
This paper proposes an energy-saving passive optical network framework (ESPON) that aims to incorporate optical network unit (ONU) sleep/doze mode into dynamic bandwidth allocation (DBA) algorithms to reduce ONU energy consumption. In the ESPON, the optical line terminal (OLT) schedules both downstream (DS) and upstream (US) transmissions in the same slot in an online and dynamic fashion whereas the ONU enters sleep mode outside the slot. The ONU sleep time is maximized based on both DS and US traffic. Moreover, during the slot, the ONU might enter doze mode when only its transmitter is idle to further improve energy efficiency. The scheduling order of data transmission, control message exchange, sleep period, and doze period defines an energy-efficient scheme under the ESPON. Three schemes are designed and evaluated in an extensive FPGA-based evaluation. Results show that whilst all the schemes significantly save ONU energy for different evaluation scenarios, the scheduling order has great impact on their performance. In addition, the ESPON allows for a scheduling order that saves ONU energy independently of the network reach.
NASA Astrophysics Data System (ADS)
Cao, Ling; Che, Wenbin
2018-05-01
For the central air-conditioning energy-saving, it is common practice to use a wide range of PTD controllers in engineering to optimize energy savings. However, the shortcomings of the PTD controller have also been magnified on this issue, such as: calculation accuracy is not enough, the calculation time is too long. Particle swarm optimization has the advantage of fast convergence. This paper is based on Particle Swarm Optimization apply in PTD controller tuning parameters in order to achieve the purpose of saving energy while ensuring comfort. The algorithm proposed in this paper can adjust the weight according to the change of population fitness, reduce the weights of particles with lower fitness and enhance the weights of particles with higher fitness in the population, and fully release the population vitality. The method in this paper is validated by the TRNSYS model based on the central air-conditioning system. The experimental results show that the room temperature fluctuation is small, the overshoot is small, the adjustment speed is fast, and the energy-saving fluctuates at 10%.
NASA Astrophysics Data System (ADS)
Pasasa, Linus; Marbun, Parlin; Mariza, Ita
2015-09-01
The purpose of this paper is to study and analyse the factors affecting customer decisions in using electricity at peak-load hours (between 17.00 to 22.00 WIB) and their behaviors towards electricity conservation in Indonesian household. The underlying rationale is to influence a reduction in energy consumption by stimulating energy saving behaviors, thereby reducing the impact of energy use on the environment. How is the correlation between the decisions in using electricity during peak load hours with the household customer's behavior towards saving electricity? The primary data is obtained by distributing questionnaires to customers of PT. PLN Jakarta Raya and Tangerang Distribution from Household segment. The data is analysed using the Structural Equation Model (SEM) and AMOS Software. The research is finding that all factors (Personal, Social, PLN Services, Psychological, and Cultural) are positively influence customer decision in using electricity at peak load hours. There is a correlation between the decisions in using electricity during peak load hours with the household customer's behavior towards saving electricity.
A review on waste heat recovery from exhaust in the ceramics industry
NASA Astrophysics Data System (ADS)
Delpech, Bertrand; Axcell, Brian; Jouhara, Hussam
2017-11-01
Following the energy crisis in 1980, many saving technologies have been investigated with attempts to implement them into various industries, one of them is the field of ceramic production. In order to comply with energy saving trends and environmental issues, the European ceramic industry sector has developed energy efficient systems which reduced significantly production time and costs and reduced total energy consumption. The last achievement is of great importance as the energy consumption of the ceramic process accounts for a significant percentage of the total production costs. More precisely, the firing stage consumes the highest amount of energy during the whole ceramic production process. The use of roller kilns, fired by natural gas, involves a loss of 50% of the input energy via the flue gas and the cooling gas exhausts. This review paper briefly describes the production process of the different ceramic products, with a focus on the ceramic sector in Europe. Due to the limited on waste heat recovery in the ceramic industry, other high temperature waste heat recovery applications are considered in the paper, such as in concrete and steel production, which could have a potential use in the ceramic industry. The state of the art technologies used in the ceramics industry are reviewed with a special interest in waste heat recovery from the ceramic process exhaust stacks and energy saving technologies.
Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring
Lin, Chung-Chih; Yu, Yan-Shuo
2015-01-01
The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the “very good signal” interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis. PMID:26640512
Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring.
Wang, Jie; Lin, Chung-Chih; Yu, Yan-Shuo; Yu, Tsang-Chu
2015-01-01
The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the "very good signal" interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis.
Cogeneration Technology Alternatives Study (CTAS) Volume 5: Analytical approach and results
NASA Technical Reports Server (NTRS)
1980-01-01
Data and information in the area of advanced energy conversion systems for industrial cogeneration applications in the 1985 to 2000 time period are provided. Six current and thirty-six advanced energy conversion systems were defined and combined with appropriate balance of plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a framework for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. Various cogeneration strategies were analyzed and both topping and bottoming (using industrial by-product heat) applications were included. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Typically fuel energy savings of 10 to 25 percent were predicted compared to traditional on site furnaces and utility electricity. Gas turbines and combined cycles indicated high overall annual cost savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal derived fuels, or coal with advanced fluid bed combustion or on site gasification systems.
Water consumption and water-saving characteristics of a ground cover rice production system
NASA Astrophysics Data System (ADS)
Jin, Xinxin; Zuo, Qiang; Ma, Wenwen; Li, Sen; Shi, Jianchu; Tao, Yueyue; Zhang, Yanan; Liu, Yang; Liu, Xiaofei; Lin, Shan; Ben-Gal, Alon
2016-09-01
The ground cover rice production system (GCRPS) offers a potentially water-saving alternative to the traditional paddy rice production system (TPRPS) by furrow irrigating mulched soil beds and maintaining soils under predominately unsaturated conditions. The guiding hypothesis of this study was that a GCRPS would decrease both physiological and non-physiological water consumption of rice compared to a TPRPS while either maintaining or enhancing production. This was tested in a two-year field experiment with three treatments (TPRPS, GCRPSsat keeping root zone average soil water content near saturated, and GCRPS80% keeping root zone average soil water content as 80-100% of field water capacity) and a greenhouse experiment with four treatments (TPRPS, GCRPSsat, GCRPSfwc keeping root zone average soil water content close to field water capacity, and GCRPS80%). The water-saving characteristics of GCRPS were analyzed as a function of the measured soil water conditions, plant parameters regarding growth and production, and water input and consumption. In the field experiment, significant reduction in both physiological and non-physiological water consumption under GCRPS lead to savings in irrigation water of ∼61-84% and reduction in total input water of ∼35-47%. Compared to TPRPS, deep drainage was reduced ∼72-88%, evaporation was lessened ∼83-89% and transpiration was limited ∼6-10% under GCRPS. In addition to saving water, plant growth and grain yield were enhanced under GCRPS due to increased soil temperature in the root zone. Therefore, water use efficiencies (WUEs), based on transpiration, irrigation and total input water, were respectively improved as much as 27%, 609% and 110% under GCRPS. Increased yield attributed to up to ∼19%, decreased deep drainage accounted for ∼75%, decreased evaporation accounted for ∼14% and reduced transpiration for ∼5% of the enhancement in WUE of input water under GCRPS, while increased runoff and water storage had negative influence on WUE (-7.5 and -3.7%, respectively) for GCRPS compared to TPRPS. The greenhouse experiment validated the results obtained in the field by simplifying the non-physiological water consumption processes, and thus confirming the relative importance of physiological processes and increased WUE under GCRPS.
NASA Astrophysics Data System (ADS)
Polosin, A. N.; Chistyakova, T. B.
2018-05-01
In this article, the authors describe mathematical modeling of polymer processing in extruders of various types used in extrusion and calender productions of film materials. The method consists of the synthesis of a static model for calculating throughput, energy consumption of the extruder, extrudate quality indices, as well as a dynamic model for evaluating polymer residence time in the extruder, on which the quality indices depend. Models are adjusted according to the extruder type (single-screw, reciprocating, twin-screw), its screw and head configuration, extruder’s work temperature conditions, and the processed polymer type. Models enable creating extruder screw configurations and determining extruder controlling action values that provide the extrudate of required quality while satisfying extruder throughput and energy consumption requirements. Model adequacy has been verified using polyolefins’ and polyvinylchloride processing data in different extruders. The program complex, based on mathematical models, has been developed in order to control extruders of various types in order to ensure resource and energy saving in multi-assortment productions of polymeric films. Using the program complex in the control system for the extrusion stage of the polymeric film productions enables improving film quality, reducing spoilage, lessening the time required for production line change-over to other throughput and film type assignment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Tengfang; Piette, Mary Ann
2004-08-05
The original scope of work was to obtain and analyze existing and emerging data in four states: California, Florida, New York, and Wisconsin. The goal of this data collection was to deliver a baseline database or recommendations for such a database that could possibly contain window and daylighting features and energy performance characteristics of Kindergarten through 12th grade (K-12) school buildings (or those of classrooms when available). In particular, data analyses were performed based upon the California Commercial End-Use Survey (CEUS) databases to understand school energy use, features of window glazing, and availability of daylighting in California K-12 schools. Themore » outcomes from this baseline task can be used to assist in establishing a database of school energy performance, assessing applications of existing technologies relevant to window and daylighting design, and identifying future R&D needs. These are in line with the overall project goals as outlined in the proposal. Through the review and analysis of this data, it is clear that there are many compounding factors impacting energy use in K-12 school buildings in the U.S., and that there are various challenges in understanding the impact of K-12 classroom energy use associated with design features of window glazing and skylight. First, the energy data in the existing CEUS databases has, at most, provided the aggregated electricity and/or gas usages for the building establishments that include other school facilities on top of the classroom spaces. Although the percentage of classroom floor area in schools is often available from the databases, there is no additional information that can be used to quantitatively segregate the EUI for classroom spaces. In order to quantify the EUI for classrooms, sub-metering of energy usage by classrooms must be obtained. Second, magnitudes of energy use for electricity lighting are not attainable from the existing databases, nor are the lighting levels contributed by artificial lighting or daylight. It is impossible to reasonably estimate the lighting energy consumption for classroom areas in the sample of schools studied in this project. Third, there are many other compounding factors that may as well influence the overall classroom energy use, e.g., ventilation, insulation, system efficiency, occupancy, control, schedules, and weather. Fourth, although we have examined the school EUI grouped by various factors such as climate zones, window and daylighting design features from the California databases, no statistically significant associations can be identified from the sampled California K-12 schools in the current California CEUS. There are opportunities to expand such analyses by developing and including more powerful CEUS databases in the future. Finally, a list of parameters is recommended for future database development and for use of future investigation in K-12 classroom energy use, window and skylight design, and possible relations between them. Some of the key parameters include: (1) Energy end use data for lighting systems, classrooms, and schools; (2) Building design and operation including features for windows and daylighting; and (3) Other key parameters and information that would be available to investigate overall energy uses, building and systems design, their operation, and services provided.« less
NASA Astrophysics Data System (ADS)
Galvis, D.; Exposito, C.; Osma, G.; Amado, L.; Ordóñez, G.
2016-07-01
This paper presents an analysis of hybrid lighting systems of Electrical Engineering Building in the Industrial University of Santander, which is a pilot of green building for warm- tropical conditions. Analysis of lighting performance of inner spaces is based on lighting curves obtained from characterization of daylighting systems of these spaces. A computation tool was made in Excel-Visual Basic to simulate the behaviour of artificial lighting system considering artificial control system, user behaviour and solar condition. Also, this tool allows to estimate the electrical energy consumption of the lighting system for a day, a month and a year.
Daylight and absenteeism--evidence from Norway.
Markussen, Simen; Røed, Knut
2015-01-01
Based on administrative register data from Norway, we examine the impact of hours of daylight on sick-leave absences among workers. Our preferred estimates imply that an additional hour of daylight increases the daily entry rate to absenteeism by 0.5 percent and the corresponding recovery rate by 0.8 percent, ceteris paribus. The overall relationship between absenteeism and daylight hours is negative. Absenteeism is also sensitive to weather conditions. Heavy snowfall raises the incidence of absence during the winter, while warm weather reduces the probability of returning to work during the summer. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Charles; Green, Andrew S.; Dahle, Douglas
2013-08-01
The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) inits buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achievingmore » savings in non-building applications.« less
Distributed Channel Allocation and Time Slot Optimization for Green Internet of Things.
Ding, Kaiqi; Zhao, Haitao; Hu, Xiping; Wei, Jibo
2017-10-28
In sustainable smart cities, power saving is a severe challenge in the energy-constrained Internet of Things (IoT). Efficient utilization of limited multiple non-overlap channels and time resources is a promising solution to reduce the network interference and save energy consumption. In this paper, we propose a joint channel allocation and time slot optimization solution for IoT. First, we propose a channel ranking algorithm which enables each node to rank its available channels based on the channel properties. Then, we propose a distributed channel allocation algorithm so that each node can choose a proper channel based on the channel ranking and its own residual energy. Finally, the sleeping duration and spectrum sensing duration are jointly optimized to maximize the normalized throughput and satisfy energy consumption constraints simultaneously. Different from the former approaches, our proposed solution requires no central coordination or any global information that each node can operate based on its own local information in a total distributed manner. Also, theoretical analysis and extensive simulations have validated that when applying our solution in the network of IoT: (i) each node can be allocated to a proper channel based on the residual energy to balance the lifetime; (ii) the network can rapidly converge to a collision-free transmission through each node's learning ability in the process of the distributed channel allocation; and (iii) the network throughput is further improved via the dynamic time slot optimization.
Optimal Implementations for Reliable Circadian Clocks
NASA Astrophysics Data System (ADS)
Hasegawa, Yoshihiko; Arita, Masanori
2014-09-01
Circadian rhythms are acquired through evolution to increase the chances for survival through synchronizing with the daylight cycle. Reliable synchronization is realized through two trade-off properties: regularity to keep time precisely, and entrainability to synchronize the internal time with daylight. We find by using a phase model with multiple inputs that achieving the maximal limit of regularity and entrainability entails many inherent features of the circadian mechanism. At the molecular level, we demonstrate the role sharing of two light inputs, phase advance and delay, as is well observed in mammals. At the behavioral level, the optimal phase-response curve inevitably contains a dead zone, a time during which light pulses neither advance nor delay the clock. We reproduce the results of phase-controlling experiments entrained by two types of periodic light pulses. Our results indicate that circadian clocks are designed optimally for reliable clockwork through evolution.
The Power of Flexibility: Autonomous Agents That Conserve Energy in Commercial Buildings
NASA Astrophysics Data System (ADS)
Kwak, Jun-young
Agent-based systems for energy conservation are now a growing area of research in multiagent systems, with applications ranging from energy management and control on the smart grid, to energy conservation in residential buildings, to energy generation and dynamic negotiations in distributed rural communities. Contributing to this area, my thesis presents new agent-based models and algorithms aiming to conserve energy in commercial buildings. More specifically, my thesis provides three sets of algorithmic contributions. First, I provide online predictive scheduling algorithms to handle massive numbers of meeting/event scheduling requests considering flexibility , which is a novel concept for capturing generic user constraints while optimizing the desired objective. Second, I present a novel BM-MDP ( Bounded-parameter Multi-objective Markov Decision Problem) model and robust algorithms for multi-objective optimization under uncertainty both at the planning and execution time. The BM-MDP model and its robust algorithms are useful in (re)scheduling events to achieve energy efficiency in the presence of uncertainty over user's preferences. Third, when multiple users contribute to energy savings, fair division of credit for such savings to incentivize users for their energy saving activities arises as an important question. I appeal to cooperative game theory and specifically to the concept of Shapley value for this fair division. Unfortunately, scaling up this Shapley value computation is a major hindrance in practice. Therefore, I present novel approximation algorithms to efficiently compute the Shapley value based on sampling and partitions and to speed up the characteristic function computation. These new models have not only advanced the state of the art in multiagent algorithms, but have actually been successfully integrated within agents dedicated to energy efficiency: SAVES, TESLA and THINC. SAVES focuses on the day-to-day energy consumption of individuals and groups in commercial buildings by reactively suggesting energy conserving alternatives. TESLA takes a long-range planning perspective and optimizes overall energy consumption of a large number of group events or meetings together. THINC provides an end-to-end integration within a single agent of energy efficient scheduling, rescheduling and credit allocation. While SAVES, TESLA and THINC thus differ in their scope and applicability, they demonstrate the utility of agent-based systems in actually reducing energy consumption in commercial buildings. I evaluate my algorithms and agents using extensive analysis on data from over 110,000 real meetings/events at multiple educational buildings including the main libraries at the University of Southern California. I also provide results on simulations and real-world experiments, clearly demonstrating the power of agent technology to assist human users in saving energy in commercial buildings.
Application of a digital technique in evaluating the reliability of shade guides.
Cal, E; Sonugelen, M; Guneri, P; Kesercioglu, A; Kose, T
2004-05-01
There appears to be a need for a reliable method for quantification of tooth colour and analysis of shade. Therefore, the primary objective of this study was to show the applicability of graphic software in colour analysis and secondly to investigate the reliability of commercial shade guides produced by the same manufacturer, using this digital technique. After confirming the reliability and reproducibility of the digital method by using self-assessed coloured images, three shade guides of the same manufacturer were photographed in daylight and in studio environments with a digital camera and saved in tagged image file format (TIFF) format. Colour analysis of each photograph was performed using the Adobe Photoshop 4.0 graphic program. Luminosity, and red, green, blue (L and RGB) values of each shade tab of each shade guide were measured and the data were subjected to statistical analysis using the repeated measure Anova test. The L and RGB values of the images taken in daylight differed significantly from those of the images taken in studio environment (P < 0.05). In both environments, the luminosity and red values of the shade tabs were significantly different from each other (P < 0.05). It was concluded that, when the environmental conditions were kept constant, the Adobe Photoshop 4.0 colour analysis program could be used to analyse the colour of images. On the other hand, the results revealed that the accuracy of shade tabs widely being used in colour matching should be readdressed.
Mobile recommender application for promoting electricity saving among Iraqis
NASA Astrophysics Data System (ADS)
Sabri, Manhal Isam; Hussain, Azham
2017-10-01
Mobile utilization has rapidly expanded due to its feasibility in executing different applications that can be used in solving everyday problems. Common issues in daily life include electricity saving. In Iraq, the Ministry of Power seriously faces such issue. This is because most households have lack access to information regarding to sufficient power consumption, as well as applications that educate about such saving. Therefore, this study aims at developing a mobile application for Iraqi to help them understand the basis for reducing electricity consumption based on the meter data supplied by the users for square meter along with the active devices and period of usage. The proposed mobile application was evaluated by 50 households from the perspective of ease of use, usefulness, ease of learning, and satisfaction. The obtained result showed that majority of the participants found the application to be ease to use, useful, easy to learn, and were satisfied with its functionalities. The study findings provide some insights about the importance of using mobile application for promoting households in Iraq to manage their power consumption behavior.
NASA Astrophysics Data System (ADS)
Stillwell, A. S.; Chini, C. M.; Schreiber, K. L.; Barker, Z. A.
2015-12-01
Energy and water are two increasingly correlated resources. Electricity generation at thermoelectric power plants requires cooling such that large water withdrawal and consumption rates are associated with electricity consumption. Drinking water and wastewater treatment require significant electricity inputs to clean, disinfect, and pump water. Due to this energy-water nexus, energy efficiency measures might be a cost-effective approach to reducing water use and water efficiency measures might support energy savings as well. This research characterizes the cost-effectiveness of different efficiency approaches in households by quantifying the direct and indirect water and energy savings that could be realized through efficiency measures, such as low-flow fixtures, energy and water efficient appliances, distributed generation, and solar water heating. Potential energy and water savings from these efficiency measures was analyzed in a product-lifetime adjusted economic model comparing efficiency measures to conventional counterparts. Results were displayed as cost abatement curves indicating the most economical measures to implement for a target reduction in water and/or energy consumption. These cost abatement curves are useful in supporting market innovation and investment in residential-scale efficiency.
Odland, D; Davis, C
1982-08-01
Plain muffins, yellow cake, baked custard, apple pie, tuna casserole, frozen tuna casserole, cheese soufflé, and meat loaf were baked in preheated and non-preheated standard gas, continuous-clean gas, standard electric, and self-cleaning electric ovens. Products generally required 5 min. or less extra baking time when cooked in non-preheated rather than in preheated ovens. The variability in baking times often was less between preheated and non-preheated ovens than among oven types. Calculated energy consumption values showed that usually less energy was required to bake products in non-preheated than in preheated ovens; savings averaged about 10 percent. Few significant differences were found in physical measurements or eating quality either between preheated and non-preheated ovens or among oven types. Overall, for the products tested, findings confirmed that preheating the oven is not essential for good product quality and, therefore, is an unnecessary use of energy.
Colorimetric analysis of outdoor illumination across varieties of atmospheric conditions.
Peyvandi, Shahram; Hernández-Andrés, Javier; Olmo, F J; Nieves, Juan Luis; Romero, Javier
2016-06-01
Solar illumination at ground level is subject to a good deal of change in spectral and colorimetric properties. With an aim of understanding the influence of atmospheric components and phases of daylight on colorimetric specifications of downward radiation, more than 5,600,000 spectral irradiance functions of daylight, sunlight, and skylight were simulated by the radiative transfer code, SBDART [Bull. Am. Meteorol. Soc.79, 2101 (1998)], under the atmospheric conditions of clear sky without aerosol particles, clear sky with aerosol particles, and overcast sky. The interquartile range of the correlated color temperatures (CCT) for daylight indicated values from 5712 to 7757 K among the three atmospheric conditions. A minimum CCT of ∼3600 K was found for daylight when aerosol particles are present in the atmosphere. Our analysis indicated that hemispheric daylight with CCT less than 3600 K may be observed in rare conditions in which the level of aerosol is high in the atmosphere. In an atmosphere with aerosol particles, we also found that the chromaticity of daylight may shift along the green-purple direction of the Planckian locus, with a magnitude depending on the spectral extinction by aerosol particles and the amount of water vapor in the atmosphere. The data analysis showed that an extremely high value of CCT, in an atmosphere without aerosol particles, for daylight and skylight at low sun, is mainly due to the effect of Chappuis absorption band of ozone at ∼600 nm. In this paper, we compare our data with well-known observations from previous research, including the ones used by the CIE to define natural daylight illuminants.
Astronomical Information Center - Naval Oceanography Portal
section Advanced Search... Sections Home Time Earth Orientation Astronomy Meteorology Oceanography Ice You the Moon Illuminated Time Universal Time and Greenwich Mean Time What is Terrestrial Time? Computing Greenwich Apparent Sidereal Time What are the U.S. Time Zones? World Time Zone Map When Does Daylight Time
NASA Astrophysics Data System (ADS)
Han, Yishi; Luo, Zhixiao; Wang, Jianhua; Min, Zhixuan; Qin, Xinyu; Sun, Yunlong
2014-09-01
In general, context-based adaptive variable length coding (CAVLC) decoding in H.264/AVC standard requires frequent access to the unstructured variable length coding tables (VLCTs) and significant memory accesses are consumed. Heavy memory accesses will cause high power consumption and time delays, which are serious problems for applications in portable multimedia devices. We propose a method for high-efficiency CAVLC decoding by using a program instead of all the VLCTs. The decoded codeword from VLCTs can be obtained without any table look-up and memory access. The experimental results show that the proposed algorithm achieves 100% memory access saving and 40% decoding time saving without degrading video quality. Additionally, the proposed algorithm shows a better performance compared with conventional CAVLC decoding, such as table look-up by sequential search, table look-up by binary search, Moon's method, and Kim's method.
Artificial light sources for simulating natural daylight and skylight.
Grum, F
1968-01-01
A review of the literature reveals the need for reliable and stable artificial light sources that can be used as simulators of daylight and skylight. In quest of such simulators a first requirement is quantitative information on the average spectral distributions of natural sources such as daylight and skylight. Recent investigations of the spectral energy characteristics of natural daylight and skylight made it possible to determine such average conditions. With these conditions established, a search was undertaken for an artificial light source that would simulate these average natural distributions with a minimum of filtering. Certain fluorescent lamps and combinations of them were considered first, but, although it was possible to achieve fairly good visual matches of daylight and skylight, the spectral characteristics and the variability of such combinations are drawbacks to their use in critical scientific work. For this purpose, therefore, xenon arc lamps were found to be superior.
A Framework for Daylighting Optimization in Whole Buildings with OpenStudio
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-08-12
We present a toolkit and workflow for leveraging the OpenStudio (Guglielmetti et al. 2010) platform to perform daylighting analysis and optimization in a whole building energy modeling (BEM) context. We have re-implemented OpenStudio's integrated Radiance and EnergyPlus functionality as an OpenStudio Measure. The OpenStudio Radiance Measure works within the OpenStudio Application and Parametric Analysis Tool, as well as the OpenStudio Server large scale analysis framework, allowing a rigorous daylighting simulation to be performed on a single building model or potentially an entire population of programmatically generated models. The Radiance simulation results can automatically inform the broader building energy model, andmore » provide dynamic daylight metrics as a basis for decision. Through introduction and example, this paper illustrates the utility of the OpenStudio building energy modeling platform to leverage existing simulation tools for integrated building energy performance simulation, daylighting analysis, and reportage.« less
Impact of savings groups on the lives of the poor
Karlan, Dean; Savonitto, Beniamino; Thuysbaert, Bram; Udry, Christopher
2017-01-01
Savings-led microfinance programs operate in poor rural communities in developing countries to establish groups that save and then lend out the accumulated savings to each other. Nonprofit organizations train villagers to create and lead these groups. In a clustered randomized evaluation spanning three African countries (Ghana, Malawi, and Uganda), we find that the promotion of these community-based microfinance groups leads to an improvement in household business outcomes and women’s empowerment. However, we do not find evidence of impacts on average consumption or other livelihoods. PMID:28270615
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ron Moon
This final scientific report documents the Industrial Technology Program (ITP) Stage 2 Concept Development effort on Data Center Energy Reduction and Management Through Real-Time Optimal Control (RTOC). Society is becoming increasingly dependent on information technology systems, driving exponential growth in demand for data center processing and an insatiable appetite for energy. David Raths noted, 'A 50,000-square-foot data center uses approximately 4 megawatts of power, or the equivalent of 57 barrels of oil a day1.' The problem has become so severe that in some cases, users are giving up raw performance for a better balance between performance and energy efficiency. Historically,more » power systems for data centers were crudely sized to meet maximum demand. Since many servers operate at 60%-90% of maximum power while only utilizing an average of 5% to 15% of their capability, there are huge inefficiencies in the consumption and delivery of power in these data centers. The goal of the 'Recovery Act: Decreasing Data Center Energy Use through Network and Infrastructure Control' is to develop a state of the art approach for autonomously and intelligently reducing and managing data center power through real-time optimal control. Advances in microelectronics and software are enabling the opportunity to realize significant data center power savings through the implementation of autonomous power management control algorithms. The first step to realizing these savings was addressed in this study through the successful creation of a flexible and scalable mathematical model (equation) for data center behavior and the formulation of an acceptable low technical risk market introduction strategy leveraging commercial hardware and software familiar to the data center market. Follow-on Stage 3 Concept Development efforts include predictive modeling and simulation of algorithm performance, prototype demonstrations with representative data center equipment to verify requisite performance and continued commercial partnering agreement formation to ensure uninterrupted development, and deployment of the real-time optimal control algorithm. As a software implementable technique for reducing power consumption, the RTOC has two very desirable traits supporting rapid prototyping and ultimately widespread dissemination. First, very little capital is required for implementation. No major infrastructure modifications are required and there is no need to purchase expensive capital equipment. Second, the RTOC can be rolled out incrementally. Therefore, the effectiveness can be proven without a large scale initial roll out. Through the use of the Impact Projections Model provided by the DOE, monetary savings in excess of $100M in 2020 and billions by 2040 are predicted. In terms of energy savings, the model predicts a primary energy displacement of 260 trillion BTUs (33 trillion kWh), or a 50% reduction in server power consumption. The model also predicts a corresponding reduction of pollutants such as SO2 and NOx in excess of 100,000 metric tonnes assuming the RTOC is fully deployed. While additional development and prototyping is required to validate these predictions, the relative low cost and ease of implementation compared to large capital projects makes it an ideal candidate for further investigation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandt, James M.; Devine, Karen Dragon; Gentile, Ann C.
2014-09-01
As computer systems grow in both size and complexity, the need for applications and run-time systems to adjust to their dynamic environment also grows. The goal of the RAAMP LDRD was to combine static architecture information and real-time system state with algorithms to conserve power, reduce communication costs, and avoid network contention. We devel- oped new data collection and aggregation tools to extract static hardware information (e.g., node/core hierarchy, network routing) as well as real-time performance data (e.g., CPU uti- lization, power consumption, memory bandwidth saturation, percentage of used bandwidth, number of network stalls). We created application interfaces that allowedmore » this data to be used easily by algorithms. Finally, we demonstrated the benefit of integrating system and application information for two use cases. The first used real-time power consumption and memory bandwidth saturation data to throttle concurrency to save power without increasing application execution time. The second used static or real-time network traffic information to reduce or avoid network congestion by remapping MPI tasks to allocated processors. Results from our work are summarized in this report; more details are available in our publications [2, 6, 14, 16, 22, 29, 38, 44, 51, 54].« less
2017-12-08
NASA image acquired August 29, 2012 1:57 a.m EDT Annotated view here: bit.ly/RsFT9Y Hurricane Isaac lit up by moonlight as it spins over the city of New Orleans, La. at 1:57 am central daylight savings time the morning of August 29, 2012. The Suomi National Polar-orbiting Partnership (NPP) satellite captured these images with its Visible Infrared Imaging Radiometer Suite (VIIRS). The "day-night band" of VIIRS detects light in a range of wavelengths from green to near-infrared and uses light intensification to enable the detection of dim signals. Suomi NPP is the result of a partnership between NASA, the National Oceanic and Atmospheric Administration and the Department of Defense. Image Credit: NASA/NOAA, Earth Observatory NASA Earth Observatory image by Jesse Allen and Robert Simmon, using VIIRS Day Night Band data. Credit: NASA Earth Observatory NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Evaluation of an antibiotic intravenous to oral sequential therapy program.
Pablos, Ana I; Escobar, Ismael; Albiñana, Sandra; Serrano, Olga; Ferrari, José M; Herreros de Tejada, Alberto
2005-01-01
This study was designed to analyse the drug consumption difference and economic impact of an antibiotic sequential therapy focused on quinolones. We studied the consumption of quinolones (ofloxacin/levofloxacin and ciprofloxacin) 6 months before and after the implementation of a sequential therapy program in hospitalised patients. It was calculated for each antibiotic, in its oral and intravenous forms, in defined daily dose (DDD/100 stays per day) and economical terms (drug acquisition cost). At the beginning of the program ofloxacin was replaced by levofloxacin and, since their clinical uses are similar, the consumption of both drugs was compared during the period. In economic terms, the consumption of intravenous quinolones decreased 60% whereas the consumption of oral quinolones increased 66%. In DDD/100 stays per day, intravenous forms consumption decreased 53% and oral forms consumption increased 36%. Focusing on quinolones, the implementation of a sequential therapy program based on promoting an early switch from intravenous to oral regimen has proved its capacity to alter the utilisation profile of these antibiotics. The program has permitted the hospital a global saving of 41420 dollars for these drugs during the period of time considered. Copyright (c) 2004 John Wiley & Sons, Ltd.
Quantifying Adoption Rates and Energy Savings Over Time for Advanced Manufacturing Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanes, Rebecca; Carpenter Petri, Alberta C; Riddle, Matt
Energy-efficient manufacturing technologies can reduce energy consumption and lower operating costs for an individual manufacturing facility, but increased process complexity and the resulting risk of disruption means that manufacturers may be reluctant to adopt such technologies. In order to quantify potential energy savings at scales larger than a single facility, it is necessary to account for how quickly and how widely the technology will be adopted by manufacturers. This work develops a methodology for estimating energy-efficient manufacturing technology adoption rates using quantitative, objectively measurable technology characteristics, including energetic, economic and technical criteria. Twelve technology characteristics are considered, and each characteristicmore » is assigned an importance weight that reflects its impact on the overall technology adoption rate. Technology characteristic data and importance weights are used to calculate the adoption score, a number between 0 and 1 that represents how quickly the technology is likely to be adopted. The adoption score is then used to estimate parameters for the Bass diffusion curve, which quantifies the change in the number of new technology adopters in a population over time. Finally, energy savings at the sector level are calculated over time by multiplying the number of new technology adopters at each time step with the technology's facility-level energy savings. The proposed methodology will be applied to five state-of-the-art energy-efficient technologies in the carbon fiber composites sector, with technology data obtained from the Department of Energy's 2016 bandwidth study. Because the importance weights used in estimating the Bass curve parameters are subjective, a sensitivity analysis will be performed on the weights to obtain a range of parameters for each technology. The potential energy savings for each technology and the rate at which each technology is adopted in the sector are quantified and used to identify the technologies which offer the greatest cumulative sector-level energy savings over a period of 20 years. Preliminary analysis indicates that relatively simple technologies, such as efficient furnaces, will be adopted more quickly and result in greater cumulative energy savings compared to more complex technologies that require process retrofitting, such as advanced control systems.« less
Khan, Yasin; Khare, Vaibhav Rai; Mathur, Jyotirmay; ...
2015-03-26
The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building usingmore » a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.« less
Recent Advances and Research Status in Energy Conservation of Iron Ore Sintering in China
NASA Astrophysics Data System (ADS)
Wang, Yao-Zu; Zhang, Jian-Liang; Liu, Zheng-Jian; Du, Cheng-Bo
2017-11-01
For the ferrous burden of blast furnaces in China, sinter generally accounts for more than 70% and the sintering process accounts for approximately 6-10% of the total energy consumption of the iron and steel enterprise. Therefore, saving energy during the sintering process is important to reduce the energy consumption in the iron and steel industry. This paper aims to illustrate recent advances and the research status of energy conservation of iron ore sintering in China. It focuses on the development and application of energy-saving technologies such as the composite agglomeration process, sintering with high-proportion flue gas recirculation sintering, recovery of sensible heat from the sinter cooling process, homogeneous deep-bed sintering technology, and comprehensive treatment technology of leakage of sintering. Moreover, some suggestions for the future development of energy-saving technologies are put forward.
Energy use and conservation trends, 1972--1986
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klan, M.S.; Belzer, D.B.; Marsh, S.J.
1989-02-01
US trends in energy use and conservation since 1972 are analyzed in this report. That year represents the last year prior to significant energy price shocks. In 1986, an estimated 31.8 quads has been saved in the US compared with what consumption would have been if the energy use per dollar of GNP had continued on the same trend after 1972 as in the period 1960--1972. Actual US energy consumption in 1986 was 74.3 quads. It is clear that energy conservation is persistent and conservation investments continue to pay off even after initial energy price shocks have subsided. Separate analysesmore » have been conducted for the major end-use sectors (residential, commercial, industrial, and transportation). Savings have been estimated in each sector, and the factors contributing to sectoral savings identified. 19 refs., 23 figs., 26 tabs.« less
ERIC Educational Resources Information Center
Hill, Alva L.; Lawrence, Jerry
In recent years one of the most prevalent requests directed to design architects by teachers and administrative personnel is to include in the architectural program for their new school provisions for admitting more daylight into their classrooms. This guide by the American Institute of Architects National Committee on Architecture for Education…
Colour Model for Outdoor Machine Vision for Tropical Regions and its Comparison with the CIE Model
NASA Astrophysics Data System (ADS)
Sahragard, Nasrolah; Ramli, Abdul Rahman B.; Hamiruce Marhaban, Mohammad; Mansor, Shattri B.
2011-02-01
Accurate modeling of daylight and surface reflectance are very useful for most outdoor machine vision applications specifically those which are based on color recognition. Existing daylight CIE model has drawbacks that limit its ability to predict the color of incident light. These limitations include lack of considering ambient light, effects of light reflected off the ground, and context specific information. Previously developed color model is only tested for a few geographical places in North America and its accountability is under question for other places in the world. Besides, existing surface reflectance models are not easily applied to outdoor images. A reflectance model with combined diffuse and specular reflection in normalized HSV color space could be used to predict color. In this paper, a new daylight color model showing the color of daylight for a broad range of sky conditions is developed which will suit weather conditions of tropical places such as Malaysia. A comparison of this daylight color model and daylight CIE model will be discussed. The colors of matte and specular surfaces have been estimated by use of the developed color model and surface reflection function in this paper. The results are shown to be highly reliable.
31 CFR 588.302 - Effective date.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY WESTERN BALKANS STABILIZATION REGULATIONS General... interests in property are blocked pursuant to § 588.201(a)(1), 12:01 a.m. eastern daylight time, June 27...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1999-01-01
In another Office of Industrial Technologies Motor Challenge Success Story, Alcoa (formerly Alumax) aluminum reduced annual energy consumption by 12% and reduced both maintenance and noise levels. Order this fact sheet now to learn how your company can both increase energy efficiency and decrease pollution.
Field Test of Boiler Primary Loop Temperature Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glanville, P.; Rowley, P.; Schroeder, D.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
Han, Jeongyun; Lee, Eunjung; Cho, Hyunghun; Yoon, Yoonjin; Lee, Hyoseop; Rhee, Wonjong
2018-05-17
In this paper, we provide findings from an energy saving experiment in a university building, where an IoT platform with 1 Hz sampling sensors was deployed to collect electric power consumption data. The experiment was a reward setup with daily feedback delivered by an energy delegate for one week, and energy saving of 25.4% was achieved during the experiment. Post-experiment sustainability, defined as 10% or more of energy saving, was also accomplished for 44 days without any further intervention efforts. The saving was possible mainly because of the data-driven intervention designs with high-resolution data in terms of sampling frequency and number of sensors, and the high-resolution data turned out to be pivotal for an effective waste behavior investigation. While the quantitative result was encouraging, we also noticed many uncontrollable factors, such as exams, papers due, office allocation shuffling, graduation, and new-comers, that affected the result in the campus environment. To confirm that the quantitative result was due to behavior changes, rather than uncontrollable factors, we developed several data-driven behavior detection measures. With these measures, it was possible to analyze behavioral changes, as opposed to simply analyzing quantitative fluctuations. Overall, we conclude that the space-time resolution of data can be crucial for energy saving, and potentially for many other data-driven energy applications.
Laike, Thorbjörn; Morita, Takeshi
2018-01-01
The purpose of the study was to investigate seasonal variation in mood and behavior among a group of office workers in Sweden (56°N). Thirty subjects participated in this longitudinal study. The subjects kept a weekly log that included questionnaires for ratings of psychological wellbeing and daily sleep-activity diaries where they also noted time spent outdoors. The lighting conditions in the offices were subjectively evaluated during one day, five times over the year. There was a seasonal variation in positive affect and in sleep-activity behavior. Across the year, there was a large variation in the total time spent outdoors in daylight. The subjects reported seasonal variation concerning the pleasantness, variation and strength of the light in the offices and regarding the visibility in the rooms. Finally, the subjects spent most of their time indoors, relying on artificial lighting, which demonstrates the importance of the lighting quality in indoor environments.
Reifman, Jaques; Kumar, Kamal; Wesensten, Nancy J; Tountas, Nikolaos A; Balkin, Thomas J; Ramakrishnan, Sridhar
2016-12-01
Computational tools that predict the effects of daily sleep/wake amounts on neurobehavioral performance are critical components of fatigue management systems, allowing for the identification of periods during which individuals are at increased risk for performance errors. However, none of the existing computational tools is publicly available, and the commercially available tools do not account for the beneficial effects of caffeine on performance, limiting their practical utility. Here, we introduce 2B-Alert Web, an open-access tool for predicting neurobehavioral performance, which accounts for the effects of sleep/wake schedules, time of day, and caffeine consumption, while incorporating the latest scientific findings in sleep restriction, sleep extension, and recovery sleep. We combined our validated Unified Model of Performance and our validated caffeine model to form a single, integrated modeling framework instantiated as a Web-enabled tool. 2B-Alert Web allows users to input daily sleep/wake schedules and caffeine consumption (dosage and time) to obtain group-average predictions of neurobehavioral performance based on psychomotor vigilance tasks. 2B-Alert Web is accessible at: https://2b-alert-web.bhsai.org. The 2B-Alert Web tool allows users to obtain predictions for mean response time, mean reciprocal response time, and number of lapses. The graphing tool allows for simultaneous display of up to seven different sleep/wake and caffeine schedules. The schedules and corresponding predicted outputs can be saved as a Microsoft Excel file; the corresponding plots can be saved as an image file. The schedules and predictions are erased when the user logs off, thereby maintaining privacy and confidentiality. The publicly accessible 2B-Alert Web tool is available for operators, schedulers, and neurobehavioral scientists as well as the general public to determine the impact of any given sleep/wake schedule, caffeine consumption, and time of day on performance of a group of individuals. This evidence-based tool can be used as a decision aid to design effective work schedules, guide the design of future sleep restriction and caffeine studies, and increase public awareness of the effects of sleep amounts, time of day, and caffeine on alertness. © 2016 Associated Professional Sleep Societies, LLC.
The Role of Daylighting in Skilled Nursing Short-Term Rehabilitation Facilities.
Gharaveis, Arsalan; Shepley, Mardelle McCuskey; Gaines, Kristi
2016-01-01
The aim of this study is to investigate the best placement of windows in short-term rehabilitation facilities in terms of daylighting and outdoor views by exploring the impact of windows on resident perception of stress, mood, activities, and satisfaction. The physiological and psychological benefits of daylighting have made it an increasingly important topic in multidisciplinary research. Although multiple studies have been written about the impact of daylight on physiological responses, few investigations have been made into the nonvisual effects related to resident mood, satisfaction, and stress level. In addition, researchers typically propose recommendations for quantitative aspects of illuminance, rather than addressing the behavioural outcomes. A combination of qualitative and quantitative methodologies were used to address the research questions. Thirty-four participants, who were living temporarily in the inpatient rehabilitation units of two skilled nursing facilities, were subjects in semistructured interviews and a 7-question 5-scale survey. While residents expressed the need to have direct visual access to the outdoors, they indicated that daylight was of even higher benefit. Additionally, they noted that size and location of windows impacted their stress levels, moods, and activities. More than half of the facility residents reported changing their postures for either better outdoor views or less light disturbance while sleeping. The results of this study emphasize the importance of daylighting for residents in rehabilitation units. Architects should acknowledge the role of daylighting and window views in the design of rehabilitation facilities. © The Author(s) 2015.
Simulating the energy performance of holographic glazings
NASA Astrophysics Data System (ADS)
Papamichael, K.; Beltran, L.; Furler, Reto; Lee, E. S.; Selkowitz, Steven E.; Rubin, Michael
1994-09-01
The light diffraction properties of holographic diffractive structures present an opportunity to improve the daylight performance in side-lit office spaces by redirecting and reflecting sunlight off the ceiling, providing adequate daylight illumination up to 30 ft (9.14 m) from the window wall. Prior studies of prototypical holographic glazings, installed above conventional `view' windows, have shown increased daylight levels over a deeper perimeter area than clear glass, for selected sun positions. In this study, we report on the simulation of the energy performance of prototypical holographic glazings assuming a commercial office building in the inland Los Angeles climate. The simulation of the energy performance involved determination of both luminous and thermal performance. Since the optical complexity of holographic glazings prevented the use of conventional algorithms for the simulation of their luminous performance, we used a newly developed method that combines experimentally determined directional workplane illuminance coefficients with computer-based analytical routines to determine a comprehensive set of daylight factors for many sun positions. These daylight factors were then used within the DOE-2.1D energy simulation program to determine hourly daylight and energy performance over the course of an entire year for four window orientations. Since the prototypical holographic diffractive structures considered in this study were applied on single pane clear glass, we also simulated the performance of hypothetical glazings, assuming the daylight performance of the prototype holographic glazings and the thermal performance of double-pane and low-e glazings. Finally, we addressed various design and implementation issues towards potential performance improvement.
Staining paraffin embedded sections of scald of barley before paraffin removal.
Xi, K; Burnett, P A
1997-07-01
Staining of paraffin embedded sections with periodic acid-Schiff reagent and fast green before paraffin removal resulted in differentiation of barley seed and leaf tissue from fungal structures of Rhynchosporium secalis. Crystal violet, toluidine blue O and antiline blue also successfully stained fungal structures of R. secalis in barley leaf tissues. Staining of embedded sections before paraffin removal allows simple processing of a series of sections, saves time and reduces solvent consumption.
A spatially augmented reality sketching interface for architectural daylighting design.
Sheng, Yu; Yapo, Theodore C; Young, Christopher; Cutler, Barbara
2011-01-01
We present an application of interactive global illumination and spatially augmented reality to architectural daylight modeling that allows designers to explore alternative designs and new technologies for improving the sustainability of their buildings. Images of a model in the real world, captured by a camera above the scene, are processed to construct a virtual 3D model. To achieve interactive rendering rates, we use a hybrid rendering technique, leveraging radiosity to simulate the interreflectance between diffuse patches and shadow volumes to generate per-pixel direct illumination. The rendered images are then projected on the real model by four calibrated projectors to help users study the daylighting illumination. The virtual heliodon is a physical design environment in which multiple designers, a designer and a client, or a teacher and students can gather to experience animated visualizations of the natural illumination within a proposed design by controlling the time of day, season, and climate. Furthermore, participants may interactively redesign the geometry and materials of the space by manipulating physical design elements and see the updated lighting simulation. © 2011 IEEE Published by the IEEE Computer Society
Sampling strategies for radio-tracking coyotes
Smith, G.J.; Cary, J.R.; Rongstad, O.J.
1981-01-01
Ten coyotes radio-tracked for 24 h periods were most active at night and moved little during daylight hours. Home-range size determined from radio-locations of 3 adult coyotes increased with the number of locations until an asymptote was reached at about 35-40 independent day locations or 3 6 nights of hourly radio-locations. Activity of the coyote did not affect the asymptotic nature of the home-range calculations, but home-range sizes determined from more than 3 nights of hourly locations were considerably larger than home-range sizes determined from daylight locations. Coyote home-range sizes were calculated from daylight locations, full-night tracking periods, and half-night tracking periods. Full- and half-lnight sampling strategies involved obtaining hourly radio-locations during 12 and 6 h periods, respectively. The half-night sampling strategy was the best compromise for our needs, as it adequately indexed the home-range size, reduced time and energy spent, and standardized the area calculation without requiring the researcher to become completely nocturnal. Sight tracking also provided information about coyote activity and sociability.
Mekonnen, Tekeshe A.; Odden, Michelle C.; Coxson, Pamela G.; Guzman, David; Lightwood, James; Wang, Y. Claire; Bibbins-Domingo, Kirsten
2013-01-01
Background Consumption of sugar-sweetened beverage (SSB) has risen over the past two decades, with over 10 million Californians drinking one or more SSB per day. High SSB intake is associated with risk of type 2 diabetes, obesity, hypertension, and coronary heart disease (CHD). Reduction of SSB intake and the potential impact on health outcomes in California and among racial, ethnic, and low-income sub-groups has not been quantified. Methods We projected the impact of reduced SSB consumption on health outcomes among all Californians and California subpopulations from 2013 to 2022. We used the CVD Policy Model – CA, an established computer simulation of diabetes and heart disease adapted to California. We modeled a reduction in SSB intake by 10–20% as has been projected to result from proposed penny-per-ounce excise tax on SSB and modeled varying effects of this reduction on health parameters including body mass index, blood pressure, and diabetes risk. We projected avoided cases of diabetes and CHD, and associated health care cost savings in 2012 US dollars. Results Over the next decade, a 10–20% SSB consumption reduction is projected to result in a 1.8–3.4% decline in the new cases of diabetes and an additional drop of 0.5–1% in incident CHD cases and 0.5–0.9% in total myocardial infarctions. The greatest reductions are expected in African Americans, Mexican Americans, and those with limited income regardless of race and ethnicity. This reduction in SSB consumption is projected to yield $320–620 million in medical cost savings associated with diabetes cases averted and an additional savings of $14–27 million in diabetes-related CHD costs avoided. Conclusions A reduction of SSB consumption could yield substantial population health benefits and cost savings for California. In particular, racial, ethnic, and low-income subgroups of California could reap the greatest health benefits. PMID:24349119
Corporate Delivery of a Global Smart Buildings Program
Fernandes, Samuel; Granderson, Jessica; Singla, Rupam; ...
2017-11-22
Buildings account for about 40 percent of the total energy consumption in the U.S. and emit approximately one third of greenhouse gas emissions. But they also offer tremendous potential for achieving significant greenhouse gas reductions with the right savings strategies. With an increasing amount of data from buildings and advanced computational and analytical abilities, buildings can be made “smart” to optimize energy consumption and occupant comfort. Smart buildings are often characterized as having a high degree of data and system integration, connectivity and control, as well as the advanced use of data analytics. These “smarts” can enable up to 10–20%more » savings in a building, and help ensure that they persist over time. In 2009, Microsoft Corporation launched the Energy-Smart Buildings (ESB) program with a vision to improve building operations services, security and accessibility in services, and new tenant applications and services that improve productivity and optimize energy use. The ESB program focused on fault diagnostics, advanced analytics and new organizational processes and practices to support their operational integration. In addition to the ESB program, Microsoft undertook capital improvement projects that made effective use of a utility incentive program and lab consolidations over the same duration. The ESB program began with a pilot at Microsoft's Puget Sound campus that identified significant savings of up to 6–10% in the 13 pilot buildings. The success of the pilot led to a global deployment of the program. Between 2009 and 2015, there was a 23.7% reduction in annual electricity consumption (kWh) at the Puget Sound campus with 18.5% of that resulting from the ESB and lab consolidations. This article provides the results of research conducted to assess the best-practice strategies that Microsoft implemented to achieve these savings, including the fault diagnostic routines that are the foundation of the ESB program and organizational change management practices. It also presents the process that was adopted to scale the ESB program globally. We conclude with recommendations for how these successes can be generalized and replicated by other corporate enterprises.« less
Corporate Delivery of a Global Smart Buildings Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandes, Samuel; Granderson, Jessica; Singla, Rupam
Buildings account for about 40 percent of the total energy consumption in the U.S. and emit approximately one third of greenhouse gas emissions. But they also offer tremendous potential for achieving significant greenhouse gas reductions with the right savings strategies. With an increasing amount of data from buildings and advanced computational and analytical abilities, buildings can be made “smart” to optimize energy consumption and occupant comfort. Smart buildings are often characterized as having a high degree of data and system integration, connectivity and control, as well as the advanced use of data analytics. These “smarts” can enable up to 10–20%more » savings in a building, and help ensure that they persist over time. In 2009, Microsoft Corporation launched the Energy-Smart Buildings (ESB) program with a vision to improve building operations services, security and accessibility in services, and new tenant applications and services that improve productivity and optimize energy use. The ESB program focused on fault diagnostics, advanced analytics and new organizational processes and practices to support their operational integration. In addition to the ESB program, Microsoft undertook capital improvement projects that made effective use of a utility incentive program and lab consolidations over the same duration. The ESB program began with a pilot at Microsoft's Puget Sound campus that identified significant savings of up to 6–10% in the 13 pilot buildings. The success of the pilot led to a global deployment of the program. Between 2009 and 2015, there was a 23.7% reduction in annual electricity consumption (kWh) at the Puget Sound campus with 18.5% of that resulting from the ESB and lab consolidations. This article provides the results of research conducted to assess the best-practice strategies that Microsoft implemented to achieve these savings, including the fault diagnostic routines that are the foundation of the ESB program and organizational change management practices. It also presents the process that was adopted to scale the ESB program globally. We conclude with recommendations for how these successes can be generalized and replicated by other corporate enterprises.« less
Holographic diffractive structures for daylighting, phase 1
NASA Astrophysics Data System (ADS)
1985-10-01
Advanced Environmental Research Group (AERG) has researched and developed a proprietary device which will passively track the Sun throughout a wide range of latitudes, hours of the day and seasons of the year. The Holographic Diffractive Structure (HDS), consists of novel holographic diffraction grating designs applied to a substrate suitable for mounting or incorporated into window glazings. The HDS installations will be a low cost system for the controlled management of sunlight in buildings for energy savings and an enhanced lighting environment. The HDSs act to intercept sunlight and redirect it away from the immediate window area towards the darker regions at the rear of the room, or (via light guides) to interior spaces without windows, or (used on the facade of a building) to redirect sunlight into dark urban canyons or onto the facades of other nearby buildings.
NASA Astrophysics Data System (ADS)
Smith, Geoffrey B.; Earp, Alan; Franklin, Jim B.; McCredie, Geoffrey
2001-11-01
Simple quantitative performance criteria are developed for translucent materials in terms of hemispherical visible transmittance, and angular spread of transmitted luminance using a half angle. Criteria are linked to applications in luminaires and skylights with emphasis on maximising visible throughput while minimising glare. These basic criteria are also extended to angle of incidence changes which are substantial. Example data is provided showing that acrylic pigmented with spherical polymer particles can have total hemispherical transmittance with weak thickness dependence, which is better than clear sheet, while the spread of transmitted light is quite thickness-sensitive and occurs over wider angles than inorganic pigments. This combination means significantly fewer lamps can achieve specified lux levels with low glare, and smaller skylights can provide higher, more uniform daylight illuminance.
Energy Optimization Using a Case-Based Reasoning Strategy
Herrera-Viedma, Enrique
2018-01-01
At present, the domotization of homes and public buildings is becoming increasingly popular. Domotization is most commonly applied to the field of energy management, since it gives the possibility of managing the consumption of the devices connected to the electric network, the way in which the users interact with these devices, as well as other external factors that influence consumption. In buildings, Heating, Ventilation and Air Conditioning (HVAC) systems have the highest consumption rates. The systems proposed so far have not succeeded in optimizing the energy consumption associated with a HVAC system because they do not monitor all the variables involved in electricity consumption. For this reason, this article presents an agent approach that benefits from the advantages provided by a Multi-Agent architecture (MAS) deployed in a Cloud environment with a wireless sensor network (WSN) in order to achieve energy savings. The agents of the MAS learn social behavior thanks to the collection of data and the use of an artificial neural network (ANN). The proposed system has been assessed in an office building achieving an average energy savings of 41% in the experimental group offices. PMID:29543729
Energy Optimization Using a Case-Based Reasoning Strategy.
González-Briones, Alfonso; Prieto, Javier; De La Prieta, Fernando; Herrera-Viedma, Enrique; Corchado, Juan M
2018-03-15
At present, the domotization of homes and public buildings is becoming increasingly popular. Domotization is most commonly applied to the field of energy management, since it gives the possibility of managing the consumption of the devices connected to the electric network, the way in which the users interact with these devices, as well as other external factors that influence consumption. In buildings, Heating, Ventilation and Air Conditioning (HVAC) systems have the highest consumption rates. The systems proposed so far have not succeeded in optimizing the energy consumption associated with a HVAC system because they do not monitor all the variables involved in electricity consumption. For this reason, this article presents an agent approach that benefits from the advantages provided by a Multi-Agent architecture (MAS) deployed in a Cloud environment with a wireless sensor network (WSN) in order to achieve energy savings. The agents of the MAS learn social behavior thanks to the collection of data and the use of an artificial neural network (ANN). The proposed system has been assessed in an office building achieving an average energy savings of 41% in the experimental group offices.