The Noisiness of Low-Frequency One-Third Octave Bands of Noise. M.S. Thesis - Southampton Univ.
NASA Technical Reports Server (NTRS)
Lawton, B. W.
1975-01-01
This study examined the relative noisiness of low frequency one-third octave bands of noise bounded by the bands centered at 25 Hz and 200 Hz, with intensities ranging from 50 db sound pressure level (SPL) to 95 db SPL. The thirty-two subjects used a method-of-adjustment technique, producing comparison-band intensities as noisy as standard bands centered at 100 Hz and 200 Hz with intensities of 60 db SPL and 72 db SPL. Four contours of equal noisiness were developed for one-third octave bands, extending down to 25 Hz and ranging in intensity from approximately 58 db SPL to 86 db SPL. These curves were compared with the contours of equal noisiness of Kryter and Pearsons. In the region of overlap (between 50 Hz and 200 Hz) the agreement was good.
Penna, Mario; Velásquez, Nelson; Solís, Rigoberto
2008-04-01
Thresholds for evoked vocal responses and thresholds of multiunit midbrain auditory responses to pure tones and synthetic calls were investigated in males of Pleurodema thaul, as behavioral thresholds well above auditory sensitivity have been reported for other anurans. Thresholds for evoked vocal responses to synthetic advertisement calls played back at increasing intensity averaged 43 dB RMS SPL (range 31-52 dB RMS SPL), measured at the subjects' position. Number of pulses increased with stimulus intensities, reaching a plateau at about 18-39 dB above threshold and decreased at higher intensities. Latency to call followed inverse trends relative to number of pulses. Neural audiograms yielded an average best threshold in the high frequency range of 46.6 dB RMS SPL (range 41-51 dB RMS SPL) and a center frequency of 1.9 kHz (range 1.7-2.6 kHz). Auditory thresholds for a synthetic call having a carrier frequency of 2.1 kHz averaged 44 dB RMS SPL (range 39-47 dB RMS SPL). The similarity between thresholds for advertisement calling and auditory thresholds for the advertisement call indicates that male P. thaul use the full extent of their auditory sensitivity in acoustic interactions, likely an evolutionary adaptation allowing chorusing activity in low-density aggregations.
Hearing in Cichlid Fishes under Noise Conditions
Ladich, Friedrich; Schulz-Mirbach, Tanja
2013-01-01
Background Hearing thresholds of fishes are typically acquired under laboratory conditions. This does not reflect the situation in natural habitats, where ambient noise may mask their hearing sensitivities. In the current study we investigate hearing in terms of sound pressure (SPL) and particle acceleration levels (PAL) of two cichlid species within the naturally occurring range of noise levels. This enabled us to determine whether species with and without hearing specializations are differently affected by noise. Methodology/Principal Findings We investigated auditory sensitivities in the orange chromide Etroplus maculatus, which possesses anterior swim bladder extensions, and the slender lionhead cichlid Steatocranus tinanti, in which the swim bladder is much smaller and lacks extensions. E. maculatus was tested between 0.2 and 3kHz and S. tinanti between 0.1 and 0.5 kHz using the auditory evoked potential (AEP) recording technique. In both species, SPL and PAL audiograms were determined in the presence of quiet laboratory conditions (baseline) and continuous white noise of 110 and 130 dB RMS. Baseline thresholds showed greatest hearing sensitivity around 0.5 kHz (SPL) and 0.2 kHz (PAL) in E. maculatus and 0.2 kHz in S. tinanti. White noise of 110 dB elevated the thresholds by 0–11 dB (SPL) and 7–11 dB (PAL) in E. maculatus and by 1–2 dB (SPL) and by 1–4 dB (PAL) in S. tinanti. White noise of 130 dB elevated hearing thresholds by 13–29 dB (SPL) and 26–32 dB (PAL) in E. maculatus and 6–16 dB (SPL) and 6–19 dB (PAL) in S. tinanti. Conclusions Our data showed for the first time for SPL and PAL thresholds that the specialized species was masked by different noise regimes at almost all frequencies, whereas the non-specialized species was much less affected. This indicates that noise can limit sound detection and acoustic orientation differently within a single fish family. PMID:23469032
Gap detection threshold in the rat before and after auditory cortex ablation.
Syka, J; Rybalko, N; Mazelová, J; Druga, R
2002-10-01
Gap detection threshold (GDT) was measured in adult female pigmented rats (strain Long-Evans) by an operant conditioning technique with food reinforcement, before and after bilateral ablation of the auditory cortex. GDT was dependent on the frequency spectrum and intensity of the continuously present noise in which the gaps were embedded. The mean values of GDT for gaps embedded in white noise or low-frequency noise (upper cutoff frequency 3 kHz) at 70 dB sound pressure level (SPL) were 1.57+/-0.07 ms and 2.9+/-0.34 ms, respectively. Decreasing noise intensity from 80 dB SPL to 20 dB SPL produced a significant increase in GDT. The increase in GDT was relatively small in the range of 80-50 dB SPL for white noise and in the range of 80-60 dB for low-frequency noise. The minimal intensity level of the noise that enabled GDT measurement was 20 dB SPL for white noise and 30 dB SPL for low-frequency noise. Mean GDT values at these intensities were 10.6+/-3.9 ms and 31.3+/-4.2 ms, respectively. Bilateral ablation of the primary auditory cortex (complete destruction of the Te1 and partial destruction of the Te2 and Te3 areas) resulted in an increase in GDT values. The fifth day after surgery, the rats were able to detect gaps in the noise. The values of GDT observed at this time were 4.2+/-1.1 ms for white noise and 7.4+/-3.1 ms for low-frequency noise at 70 dB SPL. During the first month after cortical ablation, recovery of GDT was observed. However, 1 month after cortical ablation GDT still remained slightly higher than in controls (1.8+/-0.18 for white noise, 3.22+/-0.15 for low-frequency noise, P<0.05). A decrease in GDT values during the subsequent months was not observed.
Thomas, Megan L.A.; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L.
2017-01-01
Background Cervical and ocular Vestibular Evoked Myogenic Potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. Purpose The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level (nHL)) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Research Design Prospective Experimental. Study Sample Ten children (4–6 years) and ten young adults (24 – 35 years) with normal hearing sensitivity and middle ear function participated in the study. Data Collection and Analysis Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant’s ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Results Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or non-linearities at high levels, and 3) peSPL increased with decreased tube diameter. Measurements in participant ears suggested: 1) peSPL was approximately 3 dB larger in child compared to adult ears, and 2) peSPL was larger in response to clicks compared to 500 Hz TBs. The model predicted the following 95% confidence interval for a 100 dB nHL click: 127–136.5 dB peSPL in adult ears and 128.7–138.2 dB peSPL in child ears. The model predicted the following 95% confidence interval for a 100 dB nHL 500 Hz TB stimulus: 122.2 – 128.2 dB peSPL in adult ears and 124.8–130.8 dB peSPL in child ears. Conclusions Our findings suggest that 1) when completing VEMP testing, the stimulus is approximately 3 dB higher in a child’s ear, 2) a 500 Hz TB is recommended over a click as it has lower peSPL compared to the click, and 3) both duration and intensity should be considered when choosing VEMP stimuli. Calculating the total sound energy exposure for your chosen stimuli is recommended as it accounts for both duration and intensity. When using this calculation for children, consider adding 3 dB to the stimulus level. PMID:28534730
Thomas, Megan L A; Fitzpatrick, Denis; McCreery, Ryan; Janky, Kristen L
2017-05-01
Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. The purpose of this study was to estimate the range of peak-to-peak equivalent sound pressure levels (peSPLs) in child and adult ears in response to high intensity stimuli (i.e., 100 dB normal hearing level [nHL]) commonly used for VEMP testing and make a determination of whether acoustic stimuli levels with VEMP testing are safe for use in children. Prospective experimental. Ten children (4-6 years) and ten young adults (24-35 years) with normal hearing sensitivity and middle ear function participated in the study. Probe microphone peSPL measurements of clicks and 500 Hz tonebursts (TBs) were recorded in tubes of small, medium, and large diameter, and in a Brüel & Kjær Ear Simulator Type 4157 to assess for linearity of the stimulus at high levels. The different diameter tubes were used to approximate the range of cross-sectional areas in infant, child, and adult ears, respectively. Equivalent ear canal volume and peSPL measurements were then recorded in child and adult ears. Lower intensity levels were used in the participant's ears to limit exposure to high intensity sound. The peSPL measurements in participant ears were extrapolated using predictions from linear mixed models to determine if equivalent ear canal volume significantly contributed to overall peSPL and to estimate the mean and 95% confidence intervals of peSPLs in child and adult ears when high intensity stimulus levels (100 dB nHL) are used for VEMP testing without exposing subjects to high-intensity stimuli. Measurements from the coupler and tubes suggested: 1) each stimuli was linear, 2) there were no distortions or nonlinearities at high levels, and 3) peSPL increased with decreased tube diameter. Measurements in participant ears suggested: 1) peSPL was approximately 3 dB larger in child compared to adult ears, and 2) peSPL was larger in response to clicks compared to 500 Hz TBs. The model predicted the following 95% confidence interval for a 100 dB nHL click: 127-136.5 dB peSPL in adult ears and 128.7-138.2 dB peSPL in child ears. The model predicted the following 95% confidence interval for a 100 dB nHL 500 Hz TB stimulus: 122.2-128.2 dB peSPL in adult ears and 124.8-130.8 dB peSPL in child ears. Our findings suggest that 1) when completing VEMP testing, the stimulus is approximately 3 dB higher in a child's ear, 2) a 500 Hz TB is recommended over a click as it has lower peSPL compared to the click, and 3) both duration and intensity should be considered when choosing VEMP stimuli. Calculating the total sound energy exposure for your chosen stimuli is recommended as it accounts for both duration and intensity. When using this calculation for children, consider adding 3 dB to the stimulus level. American Academy of Audiology
Prolonged noise exposure-induced auditory threshold shifts in rats
Chen, Guang-Di; Decker, Brandon; Muthaiah, Vijaya Prakash Krishnan; Sheppard, Adam; Salvi, Richard
2014-01-01
Noise-induced hearing loss (NIHL) initially increases with exposure duration, but eventually reaches an asymptotic threshold shift (ATS) once the exposure duration exceeds 18-24 h. Equations for predicting the ATS have been developed for several species, but not for rats, even though this species is extensively used in noise exposure research. To fill this void, we exposed rats to narrowband noise (NBN, 16-20 kHz) for 5 weeks starting at 80 dB SPL in the first week and then increasing the level by 6 dB per week to a final level of 104 dB SPL. Auditory brainstem responses (ABR) were recorded before, during, and following the exposure to determine the amount of hearing loss. The noise induced threshold shift to continuous long-term exposure, defined as compound threshold shift (CTS), within and above 16-20 kHz increased with noise level at the rate of 1.82 dB threshold shift per dB of noise level (NL) above a critical level (C) of 77.2 dB SPL i.e. CTS = 1.82(NL-77.2). The normalized amplitude of the largest ABR peak measured at 100 dB SPL decreased at the rate of 3.1% per dB of NL above the critical level of 76.9 dB SPL, i.e., %ABR Reduction = 3.1%(NL-76.9). ABR thresholds measured >30 days post-exposure only partially recovered resulting in a permanent threshold shift of 30-40 dB along with severe hair cell loss in the basal, high-frequency region of the cochlea. In the rat, CTS increases with noise level with a slope similar to humans and chinchillas. The critical level (C) in the rat is similar to that of humans, but higher than that of chinchillas. PMID:25219503
Rodriguez, Amanda I; Thomas, Megan L A; Fitzpatrick, Denis; Janky, Kristen L
Vestibular evoked myogenic potential (VEMP) testing is increasingly utilized in pediatric vestibular evaluations due to its diagnostic capability to identify otolith dysfunction and feasibility of testing. However, there is evidence demonstrating that the high-intensity stimulation level required to elicit a reliable VEMP response causes acoustic trauma in adults. Despite utility of VEMP testing in children, similar findings are unknown. It is hypothesized that increased sound exposure may exist in children because differences in ear-canal volume (ECV) compared with adults, and the effect of stimulus parameters (e.g., signal duration and intensity) will alter exposure levels delivered to a child's ear. The objectives of this study are to (1) measure peak to peak equivalent sound pressure levels (peSPL) in children with normal hearing (CNH) and young adults with normal hearing (ANH) using high-intensity VEMP stimuli, (2) determine the effect of ECV on peSPL and calculate a safe exposure level for VEMP, and (3) assess whether cochlear changes exist after VEMP exposure. This was a 2-phase approach. Fifteen CNH and 12 ANH participated in phase I. Equivalent ECV was measured. In 1 ear, peSPL was recorded for 5 seconds at 105 to 125 dB SPL, in 5-dB increments for 500- and 750-Hz tone bursts. Recorded peSPL values (accounting for stimulus duration) were then used to calculate safe sound energy exposure values for VEMP testing using the 132-dB recommended energy allowance from the 2003 European Union Guidelines. Fifteen CNH and 10 ANH received cervical and ocular VEMP testing in 1 ear in phase II. Subjects completed tympanometry, pre- and postaudiometric threshold testing, distortion product otoacoustic emissions, and questionnaire addressing subjective otologic symptoms to study the effect of VEMP exposure on cochlear function. (1) In response to high-intensity stimulation levels (e.g., 125 dB SPL), CNH had significantly higher peSPL measurements and smaller ECVs compared with ANH. (2) A significant linear relationship between equivalent ECV (as measured by diagnostic tympanometry) and peSPL exists and has an effect on total sound energy exposure level; based on data from phase I, 120 dB SPL was determined to be an acoustically safe stimulation level for testing in children. (3) Using calculated safe stimulation level for VEMP testing, there were no significant effect of VEMP exposure on cochlear function (as measured by audiometric thresholds, distortion product otoacoustic emission amplitude levels, or subjective symptoms) in CNH and ANH. peSPL sound recordings in children's ears are significantly higher (~3 dB) than that in adults in response to high-intensity VEMP stimuli that are commonly practiced. Equivalent ECV contributes to peSPL delivered to the ear during VEMP testing and should be considered to determine safe acoustic VEMP stimulus parameters; children with smaller ECVs are at risk for unsafe sound exposure during routine VEMP testing, and stimuli should not exceed 120 dB SPL. Using 120 dB SPL stimulus level for children during VEMP testing yields no change to cochlear function and reliable VEMP responses.
Heinrich, Ulf-Rüdiger; Selivanova, Oxana; Schmidtmann, Irene; Feltens, Ralph; Brieger, Jürgen; Mann, Wolf J
2010-03-01
Changes in the metabolism of arachidonic acid (AA) might be part of a noise-induced compensatory mechanism with regional specificity. The released imbalance of prostaglandins and leukotrienes, both AA metabolites, might result in altered blood flow regulation in the inner ear and probably contributes to noise-induced hearing loss. The aim of this study was to gain further information about noise-dependent changes in AA metabolism in the mammalian cochlea. In this prospective animal study, 10 male guinea pigs were exposed to tone bursts for 1 h at 70 dB sound pressure level (SPL) (n = 5) or 90 dB SPL (n = 5). Five animals were used as controls. Alterations in cyclooxygenase 1 (COX-1) and 5-lipoxygenase (5-LO) expression were determined by quantitative immunohistochemical analysis in 11 cochlear regions. COX-1 expression was decreased after both 70 dB SPL and 90 dB SPL exposure in most cell types of the organ of Corti and increased in the nerve fibers of the osseous spiral lamina. 5-LO was lowered after 90 dB SPL exposure, preferentially in the third cochlear turn in the organ of Corti, in the first and second turn in spiral ganglion cells, and in all turns in the stria vascularis.
Davidson, Lisa S; Skinner, Margaret W; Holstad, Beth A; Fears, Beverly T; Richter, Marie K; Matusofsky, Margaret; Brenner, Christine; Holden, Timothy; Birath, Amy; Kettel, Jerrica L; Scollie, Susan
2009-06-01
The purpose of this study was to examine the effects of a wider instantaneous input dynamic range (IIDR) setting on speech perception and comfort in quiet and noise for children wearing the Nucleus 24 implant system and the Freedom speech processor. In addition, children's ability to understand soft and conversational level speech in relation to aided sound-field thresholds was examined. Thirty children (age, 7 to 17 years) with the Nucleus 24 cochlear implant system and the Freedom speech processor with two different IIDR settings (30 versus 40 dB) were tested on the Consonant Nucleus Consonant (CNC) word test at 50 and 60 dB SPL, the Bamford-Kowal-Bench Speech in Noise Test, and a loudness rating task for four-talker speech noise. Aided thresholds for frequency-modulated tones, narrowband noise, and recorded Ling sounds were obtained with the two IIDRs and examined in relation to CNC scores at 50 dB SPL. Speech Intelligibility Indices were calculated using the long-term average speech spectrum of the CNC words at 50 dB SPL measured at each test site and aided thresholds. Group mean CNC scores at 50 dB SPL with the 40 IIDR were significantly higher (p < 0.001) than with the 30 IIDR. Group mean CNC scores at 60 dB SPL, loudness ratings, and the signal to noise ratios-50 for Bamford-Kowal-Bench Speech in Noise Test were not significantly different for the two IIDRs. Significantly improved aided thresholds at 250 to 6000 Hz as well as higher Speech Intelligibility Indices afforded improved audibility for speech presented at soft levels (50 dB SPL). These results indicate that an increased IIDR provides improved word recognition for soft levels of speech without compromising comfort of higher levels of speech sounds or sentence recognition in noise.
Effect of increased IIDR in the nucleus freedom cochlear implant system.
Holden, Laura K; Skinner, Margaret W; Fourakis, Marios S; Holden, Timothy A
2007-10-01
The objective of this study was to evaluate the effect of the increased instantaneous input dynamic range (IIDR) in the Nucleus Freedom cochlear implant (CI) system on recipients' ability to perceive soft speech and speech in noise. Ten adult Freedom CI recipients participated. Two maps differing in IIDR were placed on each subject's processor at initial activation. The IIDR was set to 30 dB for one map and 40 dB for the other. Subjects used both maps for at least one month prior to speech perception testing. Results revealed significantly higher scores for words (50 dB SPL), for sentences in background babble (65 dB SPL), and significantly lower sound field threshold levels with the 40 compared to the 30 dB IIDR map. Ceiling effects may have contributed to non-significant findings for sentences in quiet (50 dB SPL). The Freedom's increased IIDR allows better perception of soft speech and speech in noise.
Loud speech over noise: some spectral attributes, with gender differences.
Ternström, Sten; Bohman, Mikael; Södersten, Maria
2006-03-01
In seeking an acoustic description of overloaded voice, simulated environmental noise was used to elicit loud speech. A total of 23 adults, 12 females and 11 males, read six passages of 90 s duration, over realistic noise presented over loudspeakers. The noise was canceled out, exposing the speech signal to analysis. Spectrum balance (SB) was defined as the level of the 2-6 kHz band relative to the 0.1-1 kHz band. SB averaged across many similar vowel segments became less negative with increasing sound pressure level (SPL), as described in the literature, but only at moderate SPL. At high SPL, SB exhibited a personal "saturation" point, above which the high-band level no longer increased faster than the overall SPL, or even stopped increasing altogether, on average at 90.3 dB (@30 cm) for females and 95.5 dB for males. Saturation occurred 6-8 dB below the personal maximum SPL, regardless of gender. The loudest productions were often characterized by a relative increase in low-frequency energy, apparently in a sharpened first formant. This suggests a change of vocal strategy when the high spectrum can rise no further. The progression of SB with SPL was characteristically different for individual subjects.
Munro, K J; Davis, J
2003-04-01
The purpose of the study was to compare the measured real-ear sound pressure level (SPL) of audiometer output with the derived real-ear SPL obtained by adding the coupler to dial difference (CDD) and real-ear to coupler difference (RECD) to the audiometer dial reading. The real-ear SPL and RECD were measured in one ear of 16 normally hearing subjects using a probe-tube microphone. The CDD transform and the RECD transfer function were measured in an HA1 and an HA2 2-cc coupler using an EAR-LINK foam ear-tip or a customized earmold. The RECD transfer function was measured using the EARTone ER 3A and the Audioscan RE770 insert earphone. The procedures were very reliable with mean differences on retest of less than 1 dB. The mean difference between the measured and derived real-ear SPL was generally less than 1 dB and rarely exceeded 3 dB in any subject. The CDD measured for an individual audiometer and the RECD measured for an individual ear can be used to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
Munro, K J; Lazenby, A
2001-10-01
The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
Magalhães, Ana Tereza de Matos; Goffi-Gomez, M Valéria Schmidt; Hoshino, Ana Cristina; Tsuji, Robinson Koji; Bento, Ricardo Ferreira; Brito, Rubens
2013-09-01
To identify the technological contributions of the newer version of speech processor to the first generation of multichannel cochlear implant and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL, and the preprocessing gain adjustments (adaptive dynamic range optimization). Prospective exploratory study. Cochlear implant center at hospital. Cochlear implant users of the Spectra processor with speech recognition in closed set. Seventeen patients were selected between the ages of 15 and 82 and deployed for more than 8 years. The technology update of the speech processor for the Nucleus 22. To determine Freedom's contribution, thresholds and speech perception tests were performed with the last map used with the Spectra and the maps created for Freedom. To identify the effect of the frequency allocation table, both upgraded and converted maps were programmed. One map was programmed with 25 dB T-SPL and 65 dB C-SPL and the other map with adaptive dynamic range optimization. To assess satisfaction, SADL and APHAB were used. All speech perception tests and all sound field thresholds were statistically better with the new speech processor; 64.7% of patients preferred maintaining the same frequency table that was suggested for the older processor. The sound field threshold was statistically significant at 500, 1,000, 1,500, and 2,000 Hz with 25 dB T-SPL/65 dB C-SPL. Regarding patient's satisfaction, there was a statistically significant improvement, only in the subscale of speech in noise abilities and phone use. The new technology improved the performance of patients with the first generation of multichannel cochlear implant.
NASA Astrophysics Data System (ADS)
Liang, Ruiyu; Xi, Ji; Bao, Yongqiang
2017-07-01
To improve the performance of gain compensation based on three-segment sound pressure level (SPL) in hearing aids, an improved multichannel loudness compensation method based on eight-segment SPL was proposed. Firstly, the uniform cosine modulated filter bank was designed. Then, the adjacent channels which have low or gradual slopes were adaptively merged to obtain the corresponding non-uniform cosine modulated filter according to the audiogram of hearing impaired persons. Secondly, the input speech was decomposed into sub-band signals and the SPL of every sub-band signal was computed. Meanwhile, the audible SPL range from 0 dB SPL to 120 dB SPL was equally divided into eight segments. Based on these segments, a different prescription formula was designed to compute more detailed gain to compensate according to the audiogram and the computed SPL. Finally, the enhanced signal was synthesized. Objective experiments showed the decomposed signals after cosine modulated filter bank have little distortion. Objective experiments showed that the hearing aids speech perception index (HASPI) and hearing aids speech quality index (HASQI) increased 0.083 and 0.082 on average, respectively. Subjective experiments showed the proposed algorithm can effectively improve the speech recognition of six hearing impaired persons.
Forward masking of dynamic acoustic intensity: effects of intensity region and end-level.
Olsen, Kirk N; Stevens, Catherine J
2012-01-01
Overestimation of loudness change typically occurs in response to up-ramp auditory stimuli (increasing intensity) relative to down-ramps (decreasing intensity) matched on frequency, duration, and end-level. In the experiment reported, forward masking is used to investigate a sensory component of up-ramp overestimation: persistence of excitation after stimulus presentation. White-noise and synthetic vowel 3.6 s up-ramp and down-ramp maskers were presented over two regions of intensity change (40-60 dB SPL, 60-80 dB SPL). Three participants detected 10 ms 1.5 kHz pure tone signals presented at masker-offset to signal-offset delays of 10, 20, 30, 50, 90, 170 ms. Masking magnitude was significantly greater in response to up-ramps compared with down-ramps for masker-signal delays up to and including 50 ms. When controlling for an end-level recency bias (40-60 dB SPL up-ramp vs 80-60 dB SPL down-ramp), the difference in masking magnitude between up-ramps and down-ramps was not significant at each masker-signal delay. Greater sensory persistence in response to up-ramps is argued to have minimal effect on perceptual overestimation of loudness change when response biases are controlled. An explanation based on sensory adaptation is discussed.
Grossöhmichen, Martin; Salcher, Rolf; Kreipe, Hans-Heinrich; Lenarz, Thomas; Maier, Hannes
2015-01-01
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5-141.8 eq. dB SPL; Omega/Aerial: 123.6-143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6-131.6 eq. dB SPL) and RW stimulation (108.3-128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented.
Grossöhmichen, Martin; Salcher, Rolf; Kreipe, Hans-Heinrich; Lenarz, Thomas; Maier, Hannes
2015-01-01
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented. PMID:25785860
Wahab, Suzaily; Abdul Rahman, Abdul Hamid; Sidek, Dinsuhaimi; Zakaria, Mohd. Normani
2016-01-01
Objective Electrophysiological studies, which are mostly focused on afferent pathway, have proven that auditory processing deficits exist in patients with schizophrenia. Nevertheless, reports on the suppressive effect of efferent auditory pathway on cochlear outer hair cells among schizophrenia patients are limited. The present, case-control, study examined the contralateral suppression of transient evoked otoacoustic emissions (TEOAEs) in patients with schizophrenia. Methods Participants were twenty-three healthy controls and sixteen schizophrenia patients with normal hearing, middle ear and cochlear outer hair cells function. Absolute non-linear and linear TEOAEs were measured in both ears by delivering clicks stimuli at 80 dB SPL and 60 dB SPL respectively. Subsequently, contralateral suppression was determined by subtracting the absolute TEOAEs response obtained at 60 dBpe SPL during the absence and presence of contralateral white noise delivered at 65 dB HL. No attention tasks were conducted during measurements. Results We found no significant difference in absolute TEOAEs responses at 80 dB SPL, in either diagnosis or ear groups (p>0.05). However, the overall contralateral suppression was significantly larger in schizophrenia patients (p<0.05). Specifically, patients with schizophrenia demonstrated significantly increased right ear contralateral suppression compared to healthy control (p<0.05). Conclusion The present findings suggest increased inhibitory effect of efferent auditory pathway especially on the right cochlear outer hair cells. Further studies to investigate increased suppressive effects are crucial to expand the current understanding of auditory hallucination mechanisms in schizophrenia patients. PMID:26766950
The Noisiness of Low Frequency Bands of Noise
NASA Technical Reports Server (NTRS)
Lawton, B. W.
1975-01-01
The relative noisiness of low frequency 1/3-octave bands of noise was examined. The frequency range investigated was bounded by the bands centered at 25 and 200 Hz, with intensities ranging from 50 to 95 db (SPL). Thirty-two subjects used a method of adjustment technique, producing comparison band intensities as noisy as 100 and 200 Hz standard bands at 60 and 72 db. The work resulted in contours of equal noisiness for 1/3-octave bands, ranging in intensity from approximately 58 to 86 db (SPL). These contours were compared with the standard equal noisiness contours; in the region of overlap, between 50 and 200 Hz, the agreement was good.
Budenz, Tobias; Denzinger, Annette; Schnitzler, Hans-Ulrich
2018-01-01
Bats lower the emission SPL when approaching a target. The SPL reduction has been explained by intensity compensation which implies that bats adjust the emission SPL to perceive the retuning echoes at the same level. For a better understanding of this control mechanism we recorded the echolocation signals of four Myotis myotis with an onboard microphone when foraging in the passive mode for rustling mealworms offered in two feeding dishes with different target strength, and determined the reduction rate for the emission SPL and the increase rate for the SPL of the returning echoes. When approaching the dish with higher target strength bats started the reduction of the emission SPL at a larger reaction distance (1.05 ± 0.21 m) and approached it with a lower reduction rate of 7.2 dB/halving of distance (hd), thus producing a change of echo rate at the ears of + 4 dB/hd. At the weaker target reaction distance was shorter (0.71 ± 0.24 m) and the reduction rate (9.1 dB/hd) was higher, producing a change of echo rate of-1.2 dB/hd. Independent of dish type, bats lowered the emission SPL by about 26 dB on average. In one bat where the echo SPL from both targets could be measured, the reduction of emission SPL was triggered when the echo SPL surpassed a similar threshold value around 41-42 dB. Echo SPL was not adjusted at a constant value indicating that Myotis myotis and most likely all other bats do not use a closed loop system for intensity compensation when approaching a target of interest. We propose that bats lower the emission SPL to adjust the SPL of the perceived pulse-echo-pairs to the optimal auditory range for the processing of range information and hypothesize that bats use flow field information not only to control the reduction of the approach speed to the target but also to control the reduction of emission SPL.
Liu, Zhaohui; Gong, Li; Li, Xiaofang; Ye, Lin; Wang, Bin; Liu, Jing; Qiu, Jianyong; Jiao, Huiduo; Zhang, Wendong; Chen, Jingzao; Wang, Jiuping
2012-01-01
In the present study, we determined the effect of infrasonic exposure on apoptosis and intracellular free Ca²⁺ ([Ca²⁺]i) levels in the hippocampus of adult rats. Adult rats were randomly divided into the control and infrasound exposure groups. For infrasound treatment, animals received infrasonic exposure at 90 (8 Hz) or 130 dB (8 Hz) for 2 h per day. Hippocampi were dissected, and isolated hippocampal neurons were cultured. The [Ca²⁺]i levels in hippocampal neurons from adult rat brains were determined by Fluo-3/AM staining with a confocal microscope system on days 1, 7, 14, 21 and 28 following infrasonic exposure. Apoptosis was evaluated by Annexin V-FITC and propidium iodide double staining. Positive cells were sorted and analyzed by flow cytometry. Elevated [Ca²⁺]i levels were observed on days 14 and 21 after rats received daily treatment with 90 or 130 dB sound pressure level (SPL) infrasonic exposure (p<0.01 vs. control). The highest levels of [Ca²⁺]i were detected in the 130 dB SPL infrasonic exposure group. Meanwhile, apoptosis in hippocampal neurons was found to increase on day 7 following 90 dB SPL infrasound exposure, and significantly increased on day 14. Upon 130 dB infrasound treatment, apoptosis was first observed on day 14, whereas the number of apoptotic cells gradually decreased thereafter. Additionally, a marked correlation between cell apoptosis and [Ca²⁺]i levels was found on day 14 and 21 following daily treatment with 90 and 130 dB SPL, respectively. These results demonstrate that a period of infrasonic exposure induced apoptosis and upregulated [Ca²⁺]i levels in hippocampal neurons, suggesting that infrasound may cause damage to the central nervous system (CNS) through the Ca²⁺‑mediated apoptotic pathway in hippocampal neurons.
Event-Related Potential Measures of a Violation of an Expected Increase and Decrease in Intensity
Macdonald, Margaret; Campbell, Kenneth
2013-01-01
Unexpected physical increases in the intensity of a frequently occurring “standard” auditory stimulus are experienced as obtrusive. This could either be because of a physical change, the increase in intensity of the “deviant” stimulus, or a psychological change, the violation of the expectancy for the occurrence of the lower intensity standard stimulus. Two experiments were run in which event-related potentials (ERPs) were recorded to determine whether “psychological” increments (violation of an expectancy for a lower intensity) would be processed differently than psychological decrements (violation of an expectancy for a higher intensity). Event-related potentials (ERPs) were recorded while subjects were presented with auditory tones that alternated between low and high intensity. The subjects ignored the auditory stimuli while watching a video. Deviants were created by repeating the same stimulus. In the first experiment, pairs of stimuli alternating in intensity, were presented in separate increment (H-L…H-L…H-H…H-L, in which H = 80 dB SPL and L = 60 dB SPL) and decrement conditions (L-H…L-H…L-L… L-H, in which H = 90 dB SPL and L = 80 dB SPL). The paradigm employed in the second experiment consisted of an alternating intensity pattern (H-L-H-L-H-H-H-L) or (H-L-H-L-L-L-H-L). Importantly, the stimulus prior to the deviant (the standard) and the actual deviants in both increment and decrement conditions in both experiments were physically identical (80 dB SPL tones). The repetition of the lower intensity tone therefore acted as a psychological rather than a physical decrement (a higher intensity tone was expected) while the repetition of the higher intensity tone acted as a psychological increment (a lower intensity tone was expected). The psychological increments in both experiments elicited a larger amplitude mismatch negativity (MMN) than the decrements. Thus, regardless of whether an acoustic change signals a physical increase in intensity or violates an expected decrease in intensity, a large MMN will be elicited. PMID:24143195
Discrimination of rippled-spectrum patterns in noise: A manifestation of compressive nonlinearity
Milekhina, Olga N.; Nechaev, Dmitry I.; Klishin, Vladimir O.
2017-01-01
In normal-hearing listeners, rippled-spectrum discrimination was psychophysically investigated in both silence and with a simultaneous masker background using the following two paradigms: measuring the ripple density resolution with the phase-reversal test and measuring the ripple-shift threshold with the ripple-shift test. The 0.5-oct wide signal was centered on 2 kHz, the signal levels were 50 and 80 dB SPL, and the masker levels varied from 30 to 100 dB SPL. The baseline ripple density resolutions were 8.7 oct-1 and 8.6 oct-1 for the 50-dB and 80-dB signals, respectively. The baseline ripple shift thresholds were 0.015 oct and 0.018 oct for the 50-dB and 80-dB signals, respectively. The maskers were 0.5-oct noises centered on 2 kHz (on-frequency) or 0.75 to 1.25 oct below the signal (off-frequency maskers). The effects of the maskers were as follows: (i) both on- and low-frequency maskers reduced the ripple density resolution and increased the ripple shift thresholds, (ii) the masker levels at threshold (the ripple density resolution decrease down to 3 oct–1 or ripple shift threshold increased up to 0.1 oct) increased with increasing frequency spacing between the signal and masker, (iii) the masker levels at threshold were higher for the 80-dB signal than for the 50-dB signal, and (iv) the difference between the masker levels at threshold for the 50-dB and 80-dB signals decreased with increasing frequency spacing between the masker and signal. Within the 30-dB (from 50 to 80 dB SPL) signal level, the growth of the masker level at threshold was 27.8 dB for the on-frequency masker and 9 dB for the low-frequency masker. It is assumed that the difference between the on- and low-frequency masking of the rippled-spectrum discrimination reflects the cochlear compressive non-linearity. With this assumption, the compression was 0.3 dB/dB. PMID:28346538
Bowles, Ann E; Denes, Samuel L; Shane, Michael A
2010-11-01
Ultrasonic coded transmitters (UCTs) producing frequencies of 69-83 kHz are used increasingly to track fish and invertebrates in coastal and estuarine waters. To address concerns that they might be audible to marine mammals, acoustic properties of UCTs were measured off Mission Beach, San Diego, and at the U.S. Navy TRANSDEC facility. A regression model fitted to VEMCO UCT data yielded an estimated source level of 147 dB re 1 μPa SPL @ 1 m and spreading constant of 14.0. Based on TRANSDEC measurements, five VEMCO 69 kHz UCTs had source levels ranging from 146 to 149 dB re 1 μPa SPL @ 1 m. Five Sonotronics UCTs (69 kHz and 83 kHz) had source levels ranging from 129 to 137 dB re 1 μPa SPL @ 1 m. Transmitter directionality ranged from 3.9 to 18.2 dB. Based on propagation models and published data on marine mammal auditory psychophysics, harbor seals potentially could detect the VEMCO 69 kHz UCTs at ranges between 19 and >200 m, while odontocetes potentially could detect them at much greater ranges. California sea lions were not expected to detect any of the tested UCTs at useful ranges.
Chi, Fang-Lu; Liang, Qin; Wang, Zheng-Min
2004-07-01
The objective of this study was to investigate the effect on experimental endolymphatic hydrops in guinea pigs after hyperbaric therapy. The histopathologic character of Ménière's disease is the presence of endolymphatic hydrops. Endolymphatic hypertension could be one of the factors resulting from endolymphatic hydrops. Some treatments of Ménière's disease are aimed toward preventing the endolymphatic hypertension. Exposure to pressure change has risen in recent years. Thirty-two guinea pigs were operated on the right ears to induce endolymphatic hydrops by obliterating the endolymphatic sac through an extradural posterior cranial fossa approach. After 5 weeks' survival, 12 guinea pigs were put into a chamber with an absolute atmospheric pressure of 2.2 for 3 weeks (90 minutes once a day 5 times a week). We observed the morphologic and functional changes in guinea pig cochleae of the pressure group, 4-week hydrops group (n = 10), 8-week hydrops group (n = 10), and the normal group (n = 10). We measured the hearing threshold of the auditory brainstem response, the 70-dB SPL action potential (AP) latency, the ratio of 70-dB SPL summating potential magnitude to action potential magnitude (-SP/AP) of the electrocochleogram, and the maximum scala media area (SMA) ratio, respectively. The average 70-dB SPL-SP/AP magnitude of right ears (0.29 +/- 0.09) and the average maximum SMA ratio (2.23 +/- 0.20) in the pressure group were significantly less than that in the 8-week hydrops group (0.69 +/- 0.15 and 4.04 +/- 0.52, respectively) with the same survival time (p < 0.05). The results in the pressure group were almost as similar as that in the 4-week hydrops group (0.29 +/- 0.13 and 2.22 +/- 0.20, respectively) (p > 0.05). The average hearing threshold of ABR of right ears in the pressure group (36.67 +/- 14.30-dB SPL) was lower than that of the 8-week hydrops group (44 +/-1 4.30-dB SPL), but the difference was insignificant (p > 0.05). The average 70-dB SPL AP latency of right ears in the pressure group was not significantly different from those of the 8-week hydrops group, the 4-week hydrops group, or the normal group (p > 0.05). Our findings suggest hyperbaric therapy can significantly suppress the development of endolymphatic hydrops and improve cochlear function in guinea pigs. This study provided strong evidence for the development of pressure treatment of Ménière's disease without destroying the inner ear.
Average optimal DPOAE primary tone levels in normal-hearing adults.
Marcrum, Steven C; Kummer, Peter; Kreitmayer, Christoph; Steffens, Thomas
2016-01-01
Despite great progress towards optimizing DPOAE primary tone characteristics, factors such as stimulus and intra-subject emission variability have not been addressed. The purpose of this study was to identify optimal primary tone level relationships when these sources of variability were acknowledged, and to identify any influences of test frequency. Following coupler-based measurements assessing primary tone level stability, two experiments were conducted. In experiment 1, DPOAE test-retest reliability without probe replacement was measured for f2 = 1-6 kHz with L1 = L2 = 65 dB SPL. In experiment 2, optimal L1-L2 relationships were identified for f2 = 1-6 kHz. For 20 ≤ L2 ≤ 75 dB SPL, L1 was varied 15 dB SPL above and below the recommendation of L1 = 0.4 L2 + 39 [dB SPL]. Eleven normal-hearing adults participated in experiment 1. Thirty normal-hearing adults participated in experiment 2. Stimulus variability did not exceed 0.1 dB SPL. DPOAE reliability testing revealed an across-frequency mean standard error of measurement of 0.52 dB SPL. The average optimal L1-L2 relationship was described by L1 = 0.49 L2 + 41 [dB SPL]. A significant effect of frequency was identified for 6 kHz. Including relevant sources of variability improves internal validity of a primary tone level optimization formula.
Design of a Dual Waveguide Normal Incidence Tube (DWNIT) Utilizing Energy and Modal Methods
NASA Technical Reports Server (NTRS)
Betts, Juan F.; Jones, Michael G. (Technical Monitor)
2002-01-01
This report investigates the partition design of the proposed Dual Waveguide Normal Incidence Tube (DWNIT). Some advantages provided by the DWNIT are (1) Assessment of coupling relationships between resonators in close proximity, (2) Evaluation of "smart liners", (3) Experimental validation for parallel element models, and (4) Investigation of effects of simulated angles of incidence of acoustic waves. Energy models of the two chambers were developed to determine the Sound Pressure Level (SPL) drop across the two chambers, through the use of an intensity transmission function for the chamber's partition. The models allowed the chamber's lengthwise end samples to vary. The initial partition design (2" high, 16" long, 0.25" thick) was predicted to provide at least 160 dB SPL drop across the partition with a compressive model, and at least 240 dB SPL drop with a bending model using a damping loss factor of 0.01. The end chamber sample transmissions coefficients were set to 0.1. Since these results predicted more SPL drop than required, a plate thickness optimization algorithm was developed. The results of the algorithm routine indicated that a plate with the same height and length, but with a thickness of 0.1" and 0.05 structural damping loss, would provide an adequate SPL isolation between the chambers.
The effect of gabapentin on gap detection and forward masking in young and old gerbils.
Gleich, Otto; Strutz, Jürgen
2011-01-01
Auditory temporal processing frequently appears more affected in old subjects than would be predicted by the degree of peripheral hearing loss, pointing to an age-dependent central processing deficit. In parallel, an age-dependent decline of inhibitory function has been demonstrated in the auditory pathway, suggesting a causal relationship between temporal processing and inhibition. Gabapentin has been specifically synthesized as a potential gamma-amino-butyric-acid (GABA) mimetic with the capability to cross the blood-brain barrier. Gabapentin treatment ameliorated tinnitus in a rat model and improved tinnitus annoyance in humans with acoustic trauma. Consequently, the present study evaluated the effect of gabapentin on auditory temporal processing in the gerbil model. Psychometric functions were collected for different test paradigms. (A) "Gap detection": The detection of a gap in the middle of a 800 msec broadband noise pulse was determined either at 15 or at 30 dB SL. (B) "Forward masking": The detection of a 20 msec probe stimulus following 2.5 msec after a 400 msec 40 dB SPL masker was determined with masker and probe frequency at 2.85 kHz. The effect of gabapentin was evaluated by collecting gap detection and forward masking functions before, during, and after treating gerbils with gabapentin doses of 115 or 350 mg/kg/day administered via drinking water. Data under different experimental conditions were collected for groups of 3 to 5 young (<2 years) and 6 to 10 old (>2 years) gerbils. Two-way analyses of variance for the factors age groups and treatment groups with subsequent pairwise comparisons for significant effects were used for the statistical evaluation of the data. For gap detection, mean thresholds were significantly increased in the group of old as compared with the young gerbils at 30 dB SL (young 2.0 msec; old 3.2 msec) and at 15 dB SL (young 2.9 msec; old 9.1 msec). Gabapentin had no significant effect on gap detection, and there was no significant interaction between age group and gabapentin treatment. Mean thresholds in the forward masking paradigm were significantly elevated in old (45.5 dB SPL) as compared with young (35.0 dB SPL) gerbils. Overall, gabapentin had no significant effect on masked thresholds; however, there was a significant interaction between treatment and age. Subsequent pairwise comparisons revealed no significant effect on masked thresholds in old gerbils but showed significantly elevated thresholds of young gerbils during 350 mg/kg gabapentin (38.3 dB SPL) compared with thresholds obtained in young gerbils before (32.3 dB SPL) and after (33.5 dB SPL) treatment. Gabapentin did not exert a therapeutic effect on impaired gap detection and forward masking in old gerbils. The lack of an effect of gabapentin on impaired auditory temporal processing in old gerbils and the finding of elevated masked thresholds in young gerbils can be reconciled with reports of only moderate GABAergic effects compared with other drugs (e.g., comparing elevation of GABA levels in the brain by gabapentin and vigabatrin) and effects due to binding of gabapentin to alpha-2-delta units of voltage-gated calcium channels.
The MOC reflex during active listening to speech.
Garinis, Angela C; Glattke, Theodore; Cone, Barbara K
2011-10-01
The purpose of this study was to test the hypothesis that active listening to speech would increase medial olivocochlear (MOC) efferent activity for the right vs. the left ear. Click-evoked otoacoustic emissions (CEOAEs) were evoked by 60-dB p.e. SPL clicks in 13 normally hearing adults in 4 test conditions for each ear: (a) in quiet; (b) with 60-dB SPL contralateral broadband noise; (c) with words embedded (at -3-dB signal-to-noise ratio [SNR]) in 60-dB SPL contralateral noise during which listeners directed attention to the words; and (d) for the same SNR as in the 3rd condition, with words played backwards. There was greater suppression during active listening compared with passive listening that was apparent in the latency range of 6- to 18-ms poststimulus onset. Ear differences in CEOAE amplitude were observed in all conditions, with right-ear amplitudes larger than those for the left. The absolute difference between CEOAE amplitude in quiet and with contralateral noise, a metric of suppression, was equivalent for right and left ears. When the amplitude differences were normalized, suppression was greater for noise presented to the right and the effect measured for a probe in the left ear. The findings support the theory that cortical mechanisms involved in listening to speech affect cochlear function through the MOC efferent system.
[The speech audiometry using the matrix sentence test].
Boboshko, M Yu; Zhilinskaia, E V; Warzybok, A; Maltseva, N V; Zokoll, M; Kollmeier, B
The matrix sentence test in which the five-word semantically unpredictable sentences presented under the background noise conditions are used as the speech material was designed and validated for many languages. The objective of the present study was to evaluate the Russian version of the matrix sentence test (RuMatrix test) in the listeners of different ages with normal hearing. At the first stage of the study, 35 listeners at the age from 18 to 33 year were examined. The results of the estimation of the training effect dictated the necessity of conducting two training tracks before carrying out the RuMatrix test proper. The signal-to-noise ratio at which 50% speech recognition (SRT50) was obtained was found to be -8.8±0.8 dB SNR. A significant effect of exposure to the background noise was demonstrated: the noise level of 80 and 75 Db SPL led to a considerably lower intelligibility than the noise levels in the range from 45 to 70 dB SPL; in the subsequent studies, the noise level of 65 dB SPL was used. The high test-retest reliability of the RuMatrix test was proved. At the second stage of the study, 20 young (20-40 year old) listeners and 20 aged (62-74 year old) ones were examined. The mean SRT50 in the aged patients was found to be -6.9±1.1 dB SNR which was much worse than the mean STR50 in the young subjects (-8.7±0.9 dB SNR). It is concluded that, bearing in mind the excellent comparability of the results of the RUMat rix test across different languages, it can be used as a universal tool in international research projects.
NASA Astrophysics Data System (ADS)
Mao, Xuefeng; Tian, Xiaoran; Zhou, Xinlei; Yu, Qingxu
2015-04-01
The characteristics of a fiber-optic Fabry-Perot interferometric acoustic sensor are investigated. An improved phase-generator carrier-demodulation mechanism is proposed for obtaining a high harmonic suppression ratio and stability of the demodulation results. A gold-coated polyethylene terephthalate membrane is used as the sensing diaphragm. By optimizing the parameters and the demodulation algorithm, the signal-to-noise ratio (SNR) and distortion ratio of 50.3 dB and the total harmonic distortion of 0.1% at 114 dB sound pressure level (SPL) (@ 1 kHz) are achieved, respectively. The sensor shows good temperature stability; the variation of the response is within 0.6 dB as the temperature changes from -10°C to 50°C. A sensitivity of 40 mV/Pa at 1 kHz and a frequency response range of 100 Hz to 12.5 kHz are reached, respectively. The SNR of the system is 60 dB (Re. 94 dB SPL). The sensor may be applied to photoacoustic spectrometers as a high-performance acoustic sensor.
Jet noise reduction via dispersed phase injection
NASA Astrophysics Data System (ADS)
Greska, Brent; Krothapalli, Anjaneyulu; Arakeri, Vijay
2001-11-01
A recently developed hot jet aeroacoustics facility at FMRL,FAMU-FSU College of Engineering has been used to study the far field noise characteristics of hot supersonic jets as influenced by the injection of a dispersed phase with low mass loading.The measured SPL from a fully expanded Mach 1.36 hot jet shows a peak value of about 139 dB at 40 deg from the jet axis.By injecting atomized water,the SPL are reduced in the angular region of about 30 deg to 50 deg with the maximum reduction being about 2 dB at 40 deg.However,with the use of non atomized aqueous polymer solution as a dispersed phase the noise levels are reduced over all angular positions by at least 1 dB with the maximum reduction being about 3 dB at 40 deg.The injection of a dispersed phase readily kills the screech; the initial results show promise and optimization studies are underway to find methods of further noise reduction.
Brockmeyer, Alison M; Potts, Lisa G
2011-02-01
Difficulty understanding in background noise is a common complaint of cochlear implant (CI) recipients. Programming options are available to improve speech recognition in noise for CI users including automatic dynamic range optimization (ADRO), autosensitivity control (ASC), and a two-stage adaptive beamforming algorithm (BEAM). However, the processing option that results in the best speech recognition in noise is unknown. In addition, laboratory measures of these processing options often show greater degrees of improvement than reported by participants in everyday listening situations. To address this issue, Compton-Conley and colleagues developed a test system to replicate a restaurant environment. The R-SPACE™ consists of eight loudspeakers positioned in a 360 degree arc and utilizes a recording made at a restaurant of background noise. The present study measured speech recognition in the R-SPACE with four processing options: standard dual-port directional (STD), ADRO, ASC, and BEAM. A repeated-measures, within-subject design was used to evaluate the four different processing options at two noise levels. Twenty-seven unilateral and three bilateral adult Nucleus Freedom CI recipients. The participants' everyday program (with no additional processing) was used as the STD program. ADRO, ASC, and BEAM were added individually to the STD program to create a total of four programs. Participants repeated Hearing in Noise Test sentences presented at 0 degrees azimuth with R-SPACE restaurant noise at two noise levels, 60 and 70 dB SPL. The reception threshold for sentences (RTS) was obtained for each processing condition and noise level. In 60 dB SPL noise, BEAM processing resulted in the best RTS, with a significant improvement over STD and ADRO processing. In 70 dB SPL noise, ASC and BEAM processing had significantly better mean RTSs compared to STD and ADRO processing. Comparison of noise levels showed that STD and BEAM processing resulted in significantly poorer RTSs in 70 dB SPL noise compared to the performance with these processing conditions in 60 dB SPL noise. Bilateral participants demonstrated a bilateral improvement compared to the better monaural condition for both noise levels and all processing conditions, except ASC in 60 dB SPL noise. The results of this study suggest that the use of processing options that utilize noise reduction, like those available in ASC and BEAM, improve a CI recipient's ability to understand speech in noise in listening situations similar to those experienced in the real world. The choice of the best processing option is dependent on the noise level, with BEAM best at moderate noise levels and ASC best at loud noise levels for unilateral CI recipients. Therefore, multiple noise programs or a combination of processing options may be necessary to provide CI users with the best performance in a variety of listening situations. American Academy of Audiology.
Wardenga, Nina; Batsoulis, Cornelia; Wagener, Kirsten C; Brand, Thomas; Lenarz, Thomas; Maier, Hannes
2015-01-01
The aim of this study was to determine the relationship between hearing loss and speech reception threshold (SRT) in a fixed noise condition using the German Oldenburg sentence test (OLSA). After training with two easily-audible lists of the OLSA, SRTs were determined monaurally with headphones at a fixed noise level of 65 dB SPL using a standard adaptive procedure, converging to 50% speech intelligibility. Data was obtained from 315 ears of 177 subjects with hearing losses ranging from -5 to 90 dB HL pure-tone average (PTA, 0.5, 1, 2, 3 kHz). Two domains were identified with a linear dependence of SRT on PTA. The SRT increased with a slope of 0.094 ± 0.006 dB SNR/dB HL (standard deviation (SD) of residuals = 1.17 dB) for PTAs < 47 dB HL and with a slope of 0.811 ± 0.049 dB SNR/dB HL (SD of residuals = 5.54 dB) for higher PTAs. The OLSA can be applied to subjects with a wide range of hearing losses. With 65 dB SPL fixed noise presentation level the SRT is determined by listening in noise for PTAs < ∼47 dB HL, and above it is determined by listening in quiet.
Zapp, Jascha; Schmitter, Sebastian; Schad, Lothar R
2012-09-01
To extend the parameter restrictions of a silent echo-planar imaging (sEPI) sequence using sinusoidal readout (RO) gradients, in particular with increased spatial resolution. The sound pressure level (SPL) of the most feasible configurations is compared to conventional EPI having trapezoidal RO gradients. We enhanced the sEPI sequence by integrating a parallel acquisition technique (PAT) on a 3 T magnetic resonance imaging (MRI) system. The SPL was measured for matrix sizes of 64 × 64 and 128 × 128 pixels, without and with PAT (R = 2). The signal-to-noise ratio (SNR) was examined for both sinusoidal and trapezoidal RO gradients. Compared to EPI PAT, the SPL could be reduced by up to 11.1 dB and 5.1 dB for matrix sizes of 64 × 64 and 128 × 128 pixels, respectively. The SNR of sinusoidal RO gradients is lower by a factor of 0.96 on average compared to trapezoidal RO gradients. The sEPI PAT sequence allows for 1) increased resolution, 2) expanded RO frequency range toward lower frequencies, which is in general beneficial for SPL, or 3) shortened TE, TR, and RO train length. At the same time, it generates lower SPL compared to conventional EPI for a wide range of RO frequencies while having the same imaging parameters. Copyright © 2012 Wiley Periodicals, Inc.
Johnson, Earl E
2017-11-01
To determine safe output sound pressure levels (SPL) for sound amplification devices to preserve hearing sensitivity after usage. A mathematical model consisting of the Modified Power Law (MPL) (Humes & Jesteadt, 1991 ) combined with equations for predicting temporary threshold shift (TTS) and subsequent permanent threshold shift (PTS) (Macrae, 1994b ) was used to determine safe output SPL. The study involves no new human subject measurements of loudness tolerance or threshold shifts. PTS was determined by the MPL model for 234 audiograms and the SPL output recommended by four different validated prescription recommendations for hearing aids. PTS can, on rare occasion, occur as a result of SPL delivered by hearing aids at modern day prescription recommendations. The trading relationship of safe output SPL, decibel hearing level (dB HL) threshold, and PTS was captured with algebraic expressions. Better hearing thresholds lowered the safe output SPL and higher thresholds raised the safe output SPL. Safe output SPL can consider the magnitude of unaided hearing loss. For devices not set to prescriptive levels, limiting the output SPL below the safe levels identified should protect against threshold worsening as a result of long-term usage.
Effect of infrasound on cochlear damage from exposure to a 4 kHz octave band of noise.
Harding, Gary W; Bohne, Barbara A; Lee, Steve C; Salt, Alec N
2007-03-01
Infrasound (i.e., <20 Hz for humans; <100 Hz for chinchillas) is not audible, but exposure to high-levels of infrasound will produce large movements of cochlear fluids. We speculated that high-level infrasound might bias the basilar membrane and perhaps be able to minimize noise-induced hearing loss. Chinchillas were simultaneously exposed to a 30 Hz tone at 100 dB SPL and a 4 kHz OBN at either 108 dB SPL for 1.75 h or 86 dB SPL for 24h. For each animal, the tympanic membrane (TM) in one ear was perforated ( approximately 1 mm(2)) prior to exposure to attenuate infrasound transmission to that cochlea by about 50 dB SPL. Controls included animals that were exposed to the infrasound only or the 4 kHz OBN only. ABR threshold shifts (TSs) and DPOAE level shifts (LSs) were determined pre- and post-TM-perforation and immediately post-exposure, just before cochlear fixation. The cochleae were dehydrated, embedded in plastic, and dissected into flat preparations of the organ of Corti (OC). Each dissected segment was evaluated for losses of inner hair cells (IHCs) and outer hair cells (OHCs). For each chinchilla, the magnitude and pattern of functional and hair cell losses were compared between their right and left cochleae. The TM perforation produced no ABR TS across frequency but did produce a 10-21 dB DPOAE LS from 0.6 to 2 kHz. The infrasound exposure alone resulted in a 10-20 dB ABR TS at and below 2 kHz, no DPOAE LS and no IHC or OHC losses. Exposure to the 4 kHz OBN alone at 108 dB produced a 10-50 dB ABR TS for 0.5-12 kHz, a 10-60 dB DPOAE LS for 0.6-16 kHz and severe OHC loss in the middle of the first turn. When infrasound was present during exposure to the 4 kHz OBN at 108 dB, the functional losses and OHC losses extended much further toward the apical and basal tips of the OC than in cochleae exposed to the 4 kHz OBN alone. Exposure to only the 4 kHz OBN at 86 dB produces a 10-40 dB ABR TS for 3-12 kHz and 10-30 dB DPOAE LS for 3-8 kHz but little or no OHC loss in the middle of the first turn. No differences were found in the functional and hair-cell losses from exposure to the 4 kHz OBN at 86 dB in the presence or absence of infrasound. We hypothesize that exposure to infrasound and an intense 4 kHz OBN increases cochlear damage because the large fluid movements from infrasound cause more intermixing of cochlear fluids through the damaged reticular lamina. Simultaneous infrasound and a moderate 4 kHz OBN did not increase cochlear damage because the reticular lamina rarely breaks down during this moderate level exposure.
Effect of infrasound on cochlear damage from exposure to a 4-kHz octave band of noise
Harding, Gary W.; Bohne, Barbara A.; Lee, Steve C.; Salt, Alec N.
2008-01-01
Infrasound (i.e., < 20 Hz for humans; < 100 Hz for chinchillas) is not audible, but exposure to high levels of infrasound will produce large movements of cochlear fluids. We speculated that high-level infrasound might bias the basilar membrane and perhaps be able to minimize noise-induced hearing loss. Chinchillas were simultaneously exposed to a 30 Hz tone at 100 dB SPL and a 4-kHz OBN at either 108 dB SPL for 1.75 h or 86 dB SPL for 24 h. For each animal, the tympanic membrane (TM) in one ear was perforated (~1 mm2) prior to exposure to attenuate infrasound transmission to that cochlea by about 50 dB SPL. Controls included animals that were exposed to the infrasound only or the 4-kHz OBN only. ABR threshold shifts (TSs) and DPOAE level shifts (LSs) were determined pre- and post-TM-perforation and immediately post-exposure, just before cochlear fixation. The cochleae were dehydrated, embedded in plastic, and dissected into flat preparations of the organ of Corti (OC). Each dissected segment was evaluated for losses of inner hair cells (IHCs) and outer hair cells (OHCs). For each chinchilla, the magnitude and pattern of functional and hair cell losses were compared between their right and left cochleae. The TM perforation produced no ABR TS across frequency but did produce a 10–21 dB DPOAE LS from 0.6–2 kHz. The infrasound exposure alone resulted in a 10–20 dB ABR TS at and below 2 kHz, no DPOAE LS and no IHC or OHC losses. Exposure to the 4-kHz OBN alone at 108 dB produced a 10–50 dB ABR TS for 0.5–12 kHz, a 10–60 dB DPOAE LS for 0.6–16 kHz and severe OHC loss in the middle of the first turn. When infrasound was present during exposure to the 4-kHz OBN at 108 dB, the functional losses and OHC losses extended much further toward the apical and basal tips of the OC than in cochleae exposed to the 4-kHz OBN alone. Exposure to only the 4-kHz OBN at 86 dB produces a 10–40 dB ABR TS for 3–12 kHz and 10–30 dB DPOAE LS for 3–8 kHz but little or no OHC loss in the middle of the first turn. No differences were found in the functional and hair-cell losses from exposure to the 4-kHz OBN at 86 dB in the presence or absence of infrasound. We hypothesize that exposure to infrasound and an intense 4-kHz OBN increases cochlear damage because the large fluid movements from infrasound cause more intermixing of cochlear fluids through the damaged reticular lamina. Simultaneous infrasound and a moderate 4-kHz OBN did not increase cochlear damage because the reticular lamina rarely breaks down during this moderate level exposure. PMID:17300889
Observation of ice nucleation in acoustically levitated water drops
NASA Astrophysics Data System (ADS)
Lü, Y. J.; Xie, W. J.; Wei, B.
2005-10-01
The supercooling and nucleation of acoustically levitated water drops were investigated at two different sound pressure levels (SPL). These water drops were supercooled by 13to16K at the low SPL of 160.6dB, whereas their supercoolings varied from 5to11K at the high SPL of 164.4dB. The maximum supercooling obtained in the experiments is 32K. Statistical analyses based on the classical nucleation theory reveal that the occurrence of ice nucleation in water drops is mainly confined to the surface region under acoustic levitation conditions and the enlargement of drop surface area caused by the acoustic radiation pressure reduces water supercoolability remarkably. A comparison of the nucleation rates at the two SPLs indicates that the sound pressure can strengthen the surface-dominated nucleation of water drops. The acoustic stream around levitated water drops and the cavitation effect associated with ultrasonic field are the main factors that induce surface-dominated nucleation.
Marable, Brian R; Maurissen, Jacques P J
2004-01-01
Neurotoxicity regulatory guidelines mandate that automated test systems be validated using chemicals. However, in some cases, chemicals may not necessarily be needed to prove test system validity. To examine this issue, two independent experiments were conducted to validate an automated auditory startle response (ASR) system. In Experiment 1, we used adult (PND 63) and weanling (PND 22) Sprague-Dawley rats (10/sex/dose) to determine the effect of either d-amphetamine (4.0 or 8.0 mg/kg) or clonidine (0.4 or 0.8 mg/kg) on the ASR peak amplitude (ASR PA). The startle response of each rat to a short burst of white noise (120 dB SPL) was recorded over 50 consecutive trials. The ASR PA was significantly decreased (by clonidine) and increased (by d-amphetamine) compared to controls in PND 63 rats. In PND 22 rats, the response to clonidine was similar to adults, but d-amphetamine effects were not significant. Neither drug affected the rate of the decrease in ASR PA over time (habituation). In Experiment 2, PND 31 Sprague-Dawley rats (8/sex) were presented with 150 trials consisting of either white noise bursts of variable intensity (70-120 dB SPL in 10 dB increments, presented in random order) or null (0 dB SPL) trials. Statistically significant sex- and intensity-dependent differences were detected in the ASR PA. These results suggest that in some cases, parametric modulation may be an alternative to using chemicals for test system validation.
Optimizing otoacoustic emission protocols for a UNHS program.
Hatzopoulos, S; Petruccelli, J; Ciorba, A; Martini, A
2009-01-01
To identify the optimal test protocol to screen for hearing problems in newborns, an evaluation of three distortion product otoacoustic emission (DPOAE) protocols was conducted in neonates, from a well-baby nursery (WBN) and from a neonatal intensive care unit (NICU) and compared to the performance in newborns of a more standard protocol based on transient-evoked OAEs (TEOAEs). The DPOAE protocols used asymmetrical stimulus intensities (L(1) > L(2)) with a frequency ratio of 1.22, in the following format: (P1), L(1) = 60, L(2) = 50 dB SPL; (P2), L(1) = 65, L(2) = 55 dB SPL, and (P3), L(1) = 75, L(2) = 65 dB SPL. Linear TEOAE responses, evoked by click stimuli of 75 dB peSPL, were used as controls of normal cochlear function. Five frequencies at 1.5, 2.0, 3.0, 4.0 and 5.0 kHz were tested with a common commercially available macro-based software subroutine (Otodynamics Corp, ILO-92). The project evaluated the responses from 1200 WBN infants (average age 48 h) and 350 low-birth-weight NICU infants, all randomly selected. Statistical analyses comparing the signal-to-noise ratios (S/N), at the predefined f(2) frequencies, indicated that the P1 and P2 DPOAE protocols generated similar responses. Significant S/N differences were observed in the P3 to P2 dataset comparisons. DPOAE scoring criteria were estimated from the P3 dataset using a one-sided, distribution-free confidence intervals. The scoring criteria for a 'pass' were estimated as a minimum S/N of 6.0, 7.0 and 6.0 dB at 2.0, 3.0 and 4.0 kHz, respectively. In terms of feasibility, the P3 protocol generated responses in 98% of the WBN and 94.8% of the NICU infants. All three DPOAE protocols demonstrated shorter time-recording requirements than the standard TEOAE test. The false-positive and false-negative rates for the NICU infants were estimated as 0.0028 and 0.003%, respectively.
Hunter, Eric J.; Titze, Ingo R.
2012-01-01
Purpose This study creates a more concise picture of the vocal demands placed on teachers by comparing occupational voice use with non-occupational voice use. Methods The National Center for Voice and Speech voice dosimetry databank was used to calculate voicing percentage per hour, as well as average dB SPL and F0. Occupational voice use (9am-3 PM, weekdays) and non-occupational voice use (4 PM-10 PM, weekends) were compared (57 teachers, two weeks each). Results Five key findings were uncovered: [1] similar to previous studies, occupational voicing percentage per hour is more than twice that of non-occupational; [2] teachers experienced a wide range of occupational voicing percentages per hour (30±11%/hr); [3] average occupational voice was about 1 dB SPL louder than the non-occupational voice and remained constant throughout the day; [4] occupational voice exhibited an increased pitch and trended upward throughout the day; [5] some apparent gender differences were shown. Conclusions Data regarding voicing percentages, F0 and dB SPL provide critical insight into teachers’ vocal health. Further, because non-occupational voice use is added to an already overloaded voice, it may add key insights into recovery patterns, and should be the focus of future studies. PMID:20689046
Krumm, Bianca; Klump, Georg; Köppl, Christine; Langemann, Ulrike
2017-09-27
We measured the auditory sensitivity of the barn owl ( Tyto alba ), using a behavioural Go/NoGo paradigm in two different age groups, one younger than 2 years ( n = 4) and another more than 13 years of age ( n = 3). In addition, we obtained thresholds from one individual aged 23 years, three times during its lifetime. For computing audiograms, we presented test frequencies of between 0.5 and 12 kHz, covering the hearing range of the barn owl. Average thresholds in quiet were below 0 dB sound pressure level (SPL) for frequencies between 1 and 10 kHz. The lowest mean threshold was -12.6 dB SPL at 8 kHz. Thresholds were the highest at 12 kHz, with a mean of 31.7 dB SPL. Test frequency had a significant effect on auditory threshold but age group had no significant effect. There was no significant interaction between age group and test frequency. Repeated threshold estimates over 21 years from a single individual showed only a slight increase in thresholds. We discuss the auditory sensitivity of barn owls with respect to other species and suggest that birds, which generally show a remarkable capacity for regeneration of hair cells in the basilar papilla, are naturally protected from presbycusis. © 2017 The Author(s).
NASA Astrophysics Data System (ADS)
Wada, Hiroshi; Ando, Masayoshi; Takeuchi, Masataka; Sugawara, Hironori; Koike, Takuji; Kobayashi, Toshimitsu; Hozawa, Koji; Gemma, Takashi; Nara, Makoto
2002-05-01
``Time-averaged holography'' and ``holographic interferometry'' enable recording of the complete vibration pattern of a surface within several seconds. The results appear in the form of fringes. Vibration amplitudes smaller than 100 nm are not readily measurable by these techniques, because such small amplitudes produce variations in gray level, but not fringes. In practice, to obtain clear fringes in these measurements, stimulus sound pressures higher than 100 dB SPL must be used. The phase of motion is also not obtainable from such fringe techniques. In this study, a sinusoidal phase modulation technique is described, which allows detection of both small amplitudes of motion and their phase from time-averaged speckle pattern interferometry. In this technique, the laser injection current is modulated and digital image processing is used to analyze the measured patterns. When the sound-pressure level of stimuli is between 70 and 85 dB SPL, this system is applied to measure the vibratory response of the tympanic membrane (TM) of guinea pig temporal bones at frequencies up to 4 kHz where complicated vibration modes are observed. The effect of the bulla on TM displacements is also quantified. Results indicate that this system is capable of measuring the nanometer displacements of the TM, produced by stimuli of 70 dB SPL.
Acoustic characteristics of modern Greek Orthodox Church music.
Delviniotis, Dimitrios S
2013-09-01
Some acoustic characteristics of the two types of vocal music of the Greek Orthodox Church Music, the Byzantine chant (BC) and ecclesiastical speech (ES), are studied in relation to the common Greek speech and the Western opera. Vocal samples were obtained, and their acoustic parameters of sound pressure level (SPL), fundamental frequency (F0), and the long-time average spectrum (LTAS) characteristics were analyzed. Twenty chanters, including two chanters-singers of opera, sang (BC) and read (ES) the same hymn of Byzantine music (BM), the two opera singers sang the same aria of opera, and common speech samples were obtained, and all audio were analyzed. The distribution of SPL values showed that the BC and ES have higher SPL by 9 and 12 dB, respectively, than common speech. The average F0 in ES tends to be lower than the common speech, and the smallest standard deviation (SD) of F0 values characterizes its monotonicity. The tone-scale intervals of BC are close enough to the currently accepted theory with SD equal to 0.24 semitones. The rate and extent of vibrato, which is rare in BC, equals 4.1 Hz and 0.6 semitones, respectively. The average LTAS slope is greatest in BC (+4.5 dB) but smaller than in opera (+5.7 dB). In both BC and ES, instead of a singer's formant appearing in an opera voice, a speaker's formant (SPF) was observed around 3300 Hz, with relative levels of +6.3 and +4.6 dB, respectively. The two vocal types of BM, BC, and ES differ both to each other and common Greek speech and opera style regarding SPL, the mean and SD of F0, the LTAS slope, and the relative level of SPF. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Sound levels, hearing habits and hazards of using portable cassete players
NASA Astrophysics Data System (ADS)
Hellström, P.-A.; Axelsson, A.
1988-12-01
The maximum output sound pressure level ( SPL) from different types of portable cassette players (PCP's) and different headphones was analyzed by using KEMAR in one-third octave bands. The equivalent free-field dB(A) level (EqA-FFSL) was computed from the one-third octave bands corrected by the free-field to the eardrum transfer function. The dB(A) level varied between 104 dB from a low-cost PCP with supra-aural headphones (earphones with headbands and foam pads fitting against the pinna) to 126 dB from a high quality PCP with semi-aural headphones (small earphones without headbands to be used in the concha of the external ear). The cassette tapes used in this study were recorded with music, white noise, narrowband noise and pure tones. The equivalent and maximum SPL was measured in the ear canal (1 mm from eardrum) with the use of mini-microphones in 15 young subjects listening to pop music from PCP's at the highest level they considered comfortable. These SPL measurements corresponded to 112 dB(A) in free field. In a temporary threshold shift ( TTS) study, ten teenagers—four girls and six boys—listened to pop music for 1 h with PCP's at a level they enjoyed. The mean TTS value was 5-10 dB for frequencies between 1 and 8 kHz. In one subject the maximum TTS was 35 dB at 5-6 dB kHz. In order to acquire information about listening habits among youngsters using PCP's, 154 seventh and eighth graders (age 14-15) were interviewed. They used PCP's much less than expected during most of the year, but an increase was reported during the summer holidays.
An intervention for noise control of blast furnace in steel industry.
Golmohammadi, Rostam; Giahi, Omid; Aliabadi, Mohsen; Darvishi, Ebrahim
2014-01-01
Noise pollution is currently a major health risk factor for workers in industries. The aim of this study was to investigate noise pollution and implement a control intervention plan for blast furnace in a steel industry. The measurement of sound pressure level (SPL) along with frequency analysis was done with the sound-level-meter Cell-450. Personal noise exposure was performed using dosimeter TES-1345 calibrated with CEL-282. Before planning noise controls, acoustic insulation properties of the furnace control unit and workers' rest room were assessed. Control room and workers' rest room were redesigned in order to improve acoustical condition. The SPL before intervention around the Blast Furnace was 90.3 dB (L) and its dominant frequency was 4000 Hz. Besides, noise transmission loss of the control and rest rooms were 10.3 dB and 4.2 dB, respectively. After intervention, noise reduction rates in the control and rest rooms were 27.4 dB and 27.7 dB, respectively. The workers' noise dose before and after the intervention was 240% and less than 100%, respectively. Improvement the workroom acoustic conditions through noise insulation can be considered effective method for preventing workers exposure to harmful noise.
The Effects of Pre-processing Strategies for Pediatric Cochlear Implant Recipients
Rakszawski, Bernadette; Wright, Rose; Cadieux, Jamie H.; Davidson, Lisa S.; Brenner, Christine
2016-01-01
Background Cochlear implants (CIs) have been shown to improve children’s speech recognition over traditional amplification when severe to profound sensorineural hearing loss is present. Despite improvements, understanding speech at low-level intensities or in the presence of background noise remains difficult. In an effort to improve speech understanding in challenging environments, Cochlear Ltd. offers pre-processing strategies that apply various algorithms prior to mapping the signal to the internal array. Two of these strategies include Autosensitivity Control™ (ASC) and Adaptive Dynamic Range Optimization (ADRO®). Based on previous research, the manufacturer’s default pre-processing strategy for pediatrics’ everyday programs combines ASC+ADRO®. Purpose The purpose of this study is to compare pediatric speech perception performance across various pre-processing strategies while applying a specific programming protocol utilizing increased threshold (T) levels to ensure access to very low-level sounds. Research Design This was a prospective, cross-sectional, observational study. Participants completed speech perception tasks in four pre-processing conditions: no pre-processing, ADRO®, ASC, ASC+ADRO®. Study Sample Eleven pediatric Cochlear Ltd. cochlear implant users were recruited: six bilateral, one unilateral, and four bimodal. Intervention Four programs, with the participants’ everyday map, were loaded into the processor with different pre-processing strategies applied in each of the four positions: no pre-processing, ADRO®, ASC, and ASC+ADRO®. Data Collection and Analysis Participants repeated CNC words presented at 50 and 70 dB SPL in quiet and HINT sentences presented adaptively with competing R-Space noise at 60 and 70 dB SPL. Each measure was completed as participants listened with each of the four pre-processing strategies listed above. Test order and condition were randomized. A repeated-measures analysis of variance (ANOVA) was used to compare each pre-processing strategy across group data. Critical differences were utilized to determine significant score differences between each pre-processing strategy for individual participants. Results For CNC words presented at 50 dB SPL, the group data revealed significantly better scores using ASC+ADRO® compared to all other pre-processing conditions while ASC resulted in poorer scores compared to ADRO® and ASC+ADRO®. Group data for HINT sentences presented in 70 dB SPL of R-Space noise revealed significantly improved scores using ASC and ASC+ADRO® compared to no pre-processing, with ASC+ADRO® scores being better than ADRO® alone scores. Group data for CNC words presented at 70 dB SPL and adaptive HINT sentences presented in 60 dB SPL of R-Space noise showed no significant difference among conditions. Individual data showed that the pre-processing strategy yielding the best scores varied across measures and participants. Conclusions Group data reveals an advantage with ASC+ADRO® for speech perception presented at lower levels and in higher levels of background noise. Individual data revealed that the optimal pre-processing strategy varied among participants; indicating that a variety of pre-processing strategies should be explored for each CI user considering his or her performance in challenging listening environments. PMID:26905529
OVERLAP OF HEARING AND VOICING RANGES IN SINGING
Hunter, Eric J.; Titze, Ingo R.
2008-01-01
Frequency and intensity ranges in voice production by trained and untrained singers were superimposed onto the average normal human hearing range. The vocal output for all subjects was shown both in Voice Range Profiles and Spectral Level Profiles. Trained singers took greater advantage of the dynamic range of the auditory system with harmonic energy (45% of the hearing range compared to 38% for untrained vocalists). This difference seemed to come from the trained singers ablily to exploit the most sensitive part of the hearing range (around 3 to 4 kHz) through the use of the singer’s formant. The trained vocalists’ average maximum third-octave spectral band level was 95 dB SPL, compared to 80 dB SPL for untrained. PMID:19844607
OVERLAP OF HEARING AND VOICING RANGES IN SINGING.
Hunter, Eric J; Titze, Ingo R
2005-04-01
Frequency and intensity ranges in voice production by trained and untrained singers were superimposed onto the average normal human hearing range. The vocal output for all subjects was shown both in Voice Range Profiles and Spectral Level Profiles. Trained singers took greater advantage of the dynamic range of the auditory system with harmonic energy (45% of the hearing range compared to 38% for untrained vocalists). This difference seemed to come from the trained singers ablily to exploit the most sensitive part of the hearing range (around 3 to 4 kHz) through the use of the singer's formant. The trained vocalists' average maximum third-octave spectral band level was 95 dB SPL, compared to 80 dB SPL for untrained.
Sound and vibration sensitivity of VIIIth nerve fibers in the grassfrog, Rana temporaria.
Christensen-Dalsgaard, J; Jørgensen, M B
1996-10-01
We have studied the sound and vibration sensitivity of 164 amphibian papilla fibers in the VIIIth nerve of the grassfrog, Rana temporaria. The VIIIth nerve was exposed using a dorsal approach. The frogs were placed in a natural sitting posture and stimulated by free-field sound. Furthermore, the animals were stimulated with dorso-ventral vibrations, and the sound-induced vertical vibrations in the setup could be canceled by emitting vibrations in antiphase from the vibration exciter. All low-frequency fibers responded to both sound and vibration with sound thresholds from 23 dB SPL and vibration thresholds from 0.02 cm/s2. The sound and vibration sensitivity was compared for each fiber using the offset between the rate-level curves for sound and vibration stimulation as a measure of relative vibration sensitivity. When measured in this way relative vibration sensitivity decreases with frequency from 42 dB at 100 Hz to 25 dB at 400 Hz. Since sound thresholds decrease from 72 dB SPL at 100 Hz to 50 dB SPL at 400 Hz the decrease in relative vibration sensitivity reflects an increase in sound sensitivity with frequency, probably due to enhanced tympanic sensitivity at higher frequencies. In contrast, absolute vibration sensitivity is constant in most of the frequency range studied. Only small effects result from the cancellation of sound-induced vibrations. The reason for this probably is that the maximal induced vibrations in the present setup are 6-10 dB below the fibers' vibration threshold at the threshold for sound. However, these results are only valid for the present physical configuration of the setup and the high vibration-sensitivities of the fibers warrant caution whenever the auditory fibers are stimulated with free-field sound. Thus, the experiments suggest that the low-frequency sound sensitivity is not caused by sound-induced vertical vibrations. Instead, the low-frequency sound sensitivity is either tympanic or mediated through bone conduction or sound-induced pulsations of the lungs.
Stapes Displacement and Intracochlear Pressure in Response to Very High Level, Low Frequency Sounds
Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.
2018-01-01
The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (< 130 dB SPL) sound levels intracochlear pressure (PIC), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (DStap), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak PIC will vary linearly with DStap up to some saturation point. However, no direct tests of DStap, or of the relationship with PIC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between DStap and PIC to very high level sounds, measurements of DStap and PIC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of PIC were made in scala vestibuli (PSV) and scala tympani (PST), along with the SPL in the external auditory canal (PEAC), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (VStap). Stimuli were moderate (~100 dB SPL) to very high level (up to ~170 dB SPL), low frequency tones (20–2560 Hz). Both DStap and PSV increased proportionally with sound pressure level in the ear canal up to approximately ~150 dB SPL, above which both DStap and PSV showed a distinct deviation from proportionality with PEAC. Both DStap and PSV approached saturation: DStap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while PSV showed substantial frequency dependence in the saturation point. The relationship between PSV and DStap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that PSV sound pressure holds constant relationship with DStap, described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. PMID:28189837
Stecker, G Christopher; McLaughlin, Susan A; Higgins, Nathan C
2015-10-15
Whole-brain functional magnetic resonance imaging was used to measure blood-oxygenation-level-dependent (BOLD) responses in human auditory cortex (AC) to sounds with intensity varying independently in the left and right ears. Echoplanar images were acquired at 3 Tesla with sparse image acquisition once per 12-second block of sound stimulation. Combinations of binaural intensity and stimulus presentation rate were varied between blocks, and selected to allow measurement of response-intensity functions in three configurations: monaural 55-85 dB SPL, binaural 55-85 dB SPL with intensity equal in both ears, and binaural with average binaural level of 70 dB SPL and interaural level differences (ILD) ranging ±30 dB (i.e., favoring the left or right ear). Comparison of response functions equated for contralateral intensity revealed that BOLD-response magnitudes (1) generally increased with contralateral intensity, consistent with positive drive of the BOLD response by the contralateral ear, (2) were larger for contralateral monaural stimulation than for binaural stimulation, consistent with negative effects (e.g., inhibition) of ipsilateral input, which were strongest in the left hemisphere, and (3) also increased with ipsilateral intensity when contralateral input was weak, consistent with additional, positive, effects of ipsilateral stimulation. Hemispheric asymmetries in the spatial extent and overall magnitude of BOLD responses were generally consistent with previous studies demonstrating greater bilaterality of responses in the right hemisphere and stricter contralaterality in the left hemisphere. Finally, comparison of responses to fast (40/s) and slow (5/s) stimulus presentation rates revealed significant rate-dependent adaptation of the BOLD response that varied across ILD values. Copyright © 2015. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Rosa, P. T.; Fontes-Pereira, A. J.; Matusin, D. P.; von Krüger, M. A.; Pereira, W. C. A.
Bone healing is a complex process that stars after the occurrence of a fracture to restore bone optimal conditions. The gold standards for bone status evaluation are the dual energy X-ray absorptiometry and the computerized tomography. Ultrasound-based technologies have some advantages as compared to X-ray technologies: nonionizing radiation, portability and lower cost among others. Quantitative ultrasound (QUS) has been proposed in literature as a new tool to follow up the fracture healing process. QUS relates the ultrasound propagation with the bone tissue condition (normal or pathological), so, a change in wave propagation may indicate a variation in tissue properties. The most used QUS parameters are time-of-flight (TOF) and sound pressure level (SPL) of the first arriving signal (FAS). In this work, the FAS is the well known lateral wave. The aim of this work is to evaluate the relation of the TOF and SPL of the FAS and fracture inclination trace in two stages of bone healing using computational simulations. Four fracture geometries were used: normal and oblique with 30, 45 and 60 degrees. The TOF average values were 63.23 μs, 63.14 μs, 63.03 μs 62.94 μs for normal, 30, 45 and 60 degrees respectively and average SPL values were -3.83 dB -4.32 dB, -4.78 dB, -6.19 dB for normal, 30, 45 and 60 degrees respectively. The results show an inverse pattern between the amplitude and time-of-flight. These values seem to be sensible to fracture inclination trace, and in future, can be used to characterize it.
Norton, S J; Gorga, M P; Widen, J E; Folsom, R C; Sininger, Y; Cone-Wesson, B; Vohr, B R; Mascher, K; Fletcher, K
2000-10-01
The purpose of this study was to compare the performance of transient evoked otoacoustic emissions (TEOAEs), distortion product otoacoustic emissions (DPOAEs), and auditory brain stem responses (ABRs) as tools for identification of neonatal hearing impairment. A total of 4911 infants including 4478 graduates of neonatal intensive care units, 353 well babies with one or more risk factors for hearing loss (Joint Committee on Infant Hearing, 1994) and 80 well babies without risk factor who did not pass one or more neonatal test were targeted as the potential subject pool on which test performance would be assessed. During the neonatal period, they were evaluated using TEOAEs in response to an 80 dB pSPL click, DPOAE responses to two stimulus conditions (L1 = L2 = 75 dB SPL and L1 = 65 dB SPL L2 = 50 dB SPL), and ABR elicited by a 30 dB nHL click. In an effort to describe test performance, these "at-risk" infants were asked to return for behavioral audiologic assessments, using visual reinforcement audiometry (VRA) at 8 to 12 mo corrected age, regardless of neonatal test results. Sixty-four percent of these subjects returned and reliable VRA data were obtained on 95.6% of these returnees. This approach is in contrast to previous studies in which, by necessity, efforts were made to follow only those infants who "failed" the neonatal screening tests. The accuracy of the neonatal measures in predicting hearing status at 8 to 12 mo corrected age was determined. Only those infants who provided reliable, monaural VRA test results were included in the analysis. Separate analyses were performed without regard to intercurrent events (i.e., events between the neonatal and VRA tests that could cause their results to disagree), and then after accounting for the possible influence of intercurrent events such as otitis media and late-onset or progressive hearing loss. Low refer rates were achieved for the stopping criteria used in the present study, especially when a protocol similar to the one recommended in the National Institutes of Health (1993) Consensus Conference Report was followed. These analyses, however, do not completely describe test performance because they did not compare neonatal screening test results with a gold standard test of hearing. Test performance, as measured by the area under a relative operating characteristic curve, were similar for all three neonatal tests when neonatal test results were compared with VRA data obtained at 8 to 12 mo corrected age. However, ABRs were more successful at determining auditory status at 1 kHz, compared with the otoacoustic emission (OAE) tests. Performance was more similar across all three tests when they were used to identify hearing loss at 2 and 4 kHz. No test performed perfectly. Using either the two- or three-frequency pure-tone average (PTA), with a fixed false alarm rate of 20%, hit rates for the neonatal tests, in general, exceeded 80% when hearing impairment was defined as behavioral thresholds > or =30 dB HL. All three tests performed similarly when a two-frequency (2 and 4 kHz) PTA was used as the gold standard; OAE test performance decreased when a three-frequency PTA (adding 1 kHz) was used as the gold standard definition. For both PTA and all three neonatal screening measures, however, hit rate increased as the magnitude of hearing loss increased. Singly, all three neonatal hearing screening tests resulted in low refer rates, especially if referrals for follow-up were made only for the cases in which stopping criteria were not met in both ears. Following a protocol similar to that recommended in the National Institutes of Health (1993) Consensus Conference report resulted in refer rates that were less than 4%. TEOAEs at 80 dB pSPL, DPOAE at L1 = 65, L2 = 50 dB SPL and ABR at 30 dB nHL measured during the neonatal period, and as implemented in the current study, performed similarly at predicting behavioral hearing status at 8 to 12
Chronic exposure to low frequency noise at moderate levels causes impaired balance in mice.
Tamura, Haruka; Ohgami, Nobutaka; Yajima, Ichiro; Iida, Machiko; Ohgami, Kyoko; Fujii, Noriko; Itabe, Hiroyuki; Kusudo, Tastuya; Yamashita, Hitoshi; Kato, Masashi
2012-01-01
We are routinely exposed to low frequency noise (LFN; below 0.5 kHz) at moderate levels of 60-70 dB sound pressure level (SPL) generated from various sources in occupational and daily environments. LFN has been reported to affect balance in humans. However, there is limited information about the influence of chronic exposure to LFN at moderate levels for balance. In this study, we investigated whether chronic exposure to LFN at a moderate level of 70 dB SPL affects the vestibule, which is one of the organs responsible for balance in mice. Wild-type ICR mice were exposed for 1 month to LFN (0.1 kHz) and high frequency noise (HFN; 16 kHz) at 70 dB SPL at a distance of approximately 10-20 cm. Behavior analyses including rotarod, beam-crossing and footprint analyses showed impairments of balance in LFN-exposed mice but not in non-exposed mice or HFN-exposed mice. Immunohistochemical analysis showed a decreased number of vestibular hair cells and increased levels of oxidative stress in LFN-exposed mice compared to those in non-exposed mice. Our results suggest that chronic exposure to LFN at moderate levels causes impaired balance involving morphological impairments of the vestibule with enhanced levels of oxidative stress. Thus, the results of this study indicate the importance of considering the risk of chronic exposure to LFN at a moderate level for imbalance.
Stuart, Andrew; Preast, June L
2012-01-01
In previous studies, otoacoustic emissions (OAEs) have been found to be larger in normal-hearing children with sickle cell disease (SCD). It was hypothesized that some dysfunction or reduction in the medial olivocochlear efferent suppression of outer hair cell activity was responsible for this phenomenon. To test this hypothesis, contralateral suppression of transient-evoked otoacoustic emissions (TEOAEs) was examined in children with and without SCD. Thirteen African American school-aged normal-hearing children with homozygous SCD and 13 age- and gender-matched control children participated. TEOAEs were obtained bilaterally with 80 dB peSPL nonlinear click stimuli. To examine contralateral suppression, TEOAEs were obtained with 60 dB peSPL linear click stimuli with and without a contralateral 65 dB SPL white noise suppressor. Overall and half-octave band TEOAE levels were found to be larger in children with SCD relative to the normal control children (p < 0.05), consistent with previous reports of increased OAE levels. There was no significant difference (p > 0.05) in the absolute or proportional amount of TEOAE suppression as a function of group and ear. There were also no significant correlations or linear predictive relationships between TEOAE suppression and TEOAE level for either ear or group (p > 0.05). These findings do not support the notion that increased OAE levels in children with SCD are a consequence of abnormal medial olivocochlear system function as assessed with contralateral suppression of TEOAEs.
Modeling the measurements of cochlear microcirculation and hearing function after loud noise.
Arpornchayanon, Warangkana; Canis, Martin; Suckfuell, Markus; Ihler, Fritz; Olzowy, Bernhard; Strieth, Sebastian
2011-09-01
Recent findings support the crucial role of microcirculatory disturbance and ischemia for hearing impairment especially after noise-induced hearing loss (NIHL). The aim of this study was to establish an animal model for in vivo analysis of cochlear microcirculation and hearing function after a loud noise to allow precise measurements of both parameters in vivo. Randomized controlled trial. Setting. Animal study. Subjects and Methods. After assessment of normacusis (0 minutes) using evoked auditory brainstem responses (ABRs), noise (106-dB sound pressure level [SPL]) was applied to both ears in 6 guinea pigs for 30 minutes while unexposed animals served as controls. In vivo fluorescence microscopy of the stria vascularis capillaries was performed after surgical exposure of 1 cochlea. ABR measurements were derived from the contralateral ear. After noise exposure, red blood cell velocity was reduced significantly by 24.3% (120 minutes) and further decreased to 44.5% at the end of the observation (210 minutes) in contrast to stable control measurements. Vessel diameters were not affected in both groups. A gradual decrease of segmental blood flow became significant (38.1%) after 150 minutes compared with controls. Hearing thresholds shifted significantly from 20.0 ± 5.5 dB SPL (0 minutes) to 32.5 ± 4.2 dB SPL (60 minutes) only in animals exposed to loud noise. With regard to novel treatments targeting the stria vascularis in NIHL, this standardized model allows us to analyze in detail cochlear microcirculation and hearing function in vivo.
Chronic Exposure to Low Frequency Noise at Moderate Levels Causes Impaired Balance in Mice
Tamura, Haruka; Ohgami, Nobutaka; Yajima, Ichiro; Iida, Machiko; Ohgami, Kyoko; Fujii, Noriko; Itabe, Hiroyuki; Kusudo, Tastuya; Yamashita, Hitoshi; Kato, Masashi
2012-01-01
We are routinely exposed to low frequency noise (LFN; below 0.5 kHz) at moderate levels of 60–70 dB sound pressure level (SPL) generated from various sources in occupational and daily environments. LFN has been reported to affect balance in humans. However, there is limited information about the influence of chronic exposure to LFN at moderate levels for balance. In this study, we investigated whether chronic exposure to LFN at a moderate level of 70 dB SPL affects the vestibule, which is one of the organs responsible for balance in mice. Wild-type ICR mice were exposed for 1 month to LFN (0.1 kHz) and high frequency noise (HFN; 16 kHz) at 70 dB SPL at a distance of approximately 10–20 cm. Behavior analyses including rotarod, beam-crossing and footprint analyses showed impairments of balance in LFN-exposed mice but not in non-exposed mice or HFN-exposed mice. Immunohistochemical analysis showed a decreased number of vestibular hair cells and increased levels of oxidative stress in LFN-exposed mice compared to those in non-exposed mice. Our results suggest that chronic exposure to LFN at moderate levels causes impaired balance involving morphological impairments of the vestibule with enhanced levels of oxidative stress. Thus, the results of this study indicate the importance of considering the risk of chronic exposure to LFN at a moderate level for imbalance. PMID:22768129
In vivo imaging and vibration measurement of Guinea pig cochlea
NASA Astrophysics Data System (ADS)
Choudhury, Niloy; Chen, Fangyi; Zheng, Jiefu; Nuttall, Alfred L.; Jacques, Steven L.
2008-02-01
An optical coherence tomography (OCT) system was built to acquire in vivo, both images and vibration measurements of the organ of Corti of the guinea pig. The organ of Corti was viewed through a ~500-μm diameter hole in the bony wall of the scala tympani of the first cochlear turn. In imaging mode, the image was acquired as reflectance R(x,z). In vibration mode, the basilar membrane (BM) or reticular lamina (RL) was selected based on the image. Under software control, the system would move the scanning mirrors to bring the sensing volume of the measurement to the desired tissue location. To address the gain stability problem of the homodyne OCT system, arising from the system moving in and out of the quadrature point and also to resolve the 180 degree ambiguity in the phase measurement using an interferometer, a vibration calibration method is developed by adding a vibrating source to the reference arm to monitor the operating point of the interferometric system. Amplitude gain and phase of various cochlear membranes was measured for different sound pressure level (SPL) varying from 65dB SPL to 93 dB SPL.
Aerodynamics of the pseudo-glottis.
Kotby, M N; Hegazi, M A; Kamal, I; Gamal El Dien, N; Nassar, J
2009-01-01
The aim of this work is to study the hitherto unclear aerodynamic parameters of the pseudo-glottis following total laryngectomy. These parameters include airflow rate, sub-pseudo-glottic pressure (SubPsG), efficiency and resistance, as well as sound pressure level (SPL). Eighteen male patients who have undergone total laryngectomy, with an age range from 54 to 72 years, were investigated in this study. All tested patients were fluent esophageal 'voice' speakers utilizing tracheo-esophageal prosthesis. The airflow rate, SubPsG and SPL were measured. The results showed that the mean value of the airflow rate was 53 ml/s, the SubPsG pressure was 13 cm H(2)O, while the SPL was 66 dB. The normative data obtained from the true glottis in healthy age-matched subjects are 89 ml/s, 7.9 cm H(2)O and 70 dB, respectively. Other aerodynamic indices were calculated and compared to the data obtained from the true glottis. Such a comparison of the pseudo-glottic aerodynamic data to the data of the true glottis gives an insight into the mechanism of action of the pseudo-glottis. The data obtained suggests possible clinical applications in pseudo-voice training. Copyright 2009 S. Karger AG, Basel.
Numerical modeling of the sound fields in urban squares
NASA Astrophysics Data System (ADS)
Kang, Jian
2005-06-01
This paper studies the basic characteristics of sound fields in urban squares surrounded by reflecting building façades and the effectiveness of architectural changes and urban design options. A radiosity model and an image source model are developed, and a parametric study is carried out in hypothetical squares. The results show that the reverberation time (RT) is rather even in a square, whereas the early decay time (EDT) is very low in the near field, and then becomes close to RT after a rapid increase. Compared to diffuse boundaries, with geometrical boundaries the RT and EDT are significantly longer and the sound pressure level (SPL) attenuation with distance is generally smaller unless the height/side ratio is high. With a boundary diffusion coefficient of 0.2, the sound field is already close to that resulting from purely diffusely reflecting boundaries. The SPL in far field is typically 6-9 dB lower if the square side is doubled; 8 dB lower if the height of building façades is decreased from 50 m to 6 m (diffuse boundaries); 5 dB (diffuse boundaries) or 2 dB (geometrical boundaries) lower if the length/width ratio is increased from 1 to 4; and 10-12 dB lower if the boundary absorption coefficient is increased from 0.1 to 0.9. .
Numerical modeling of the sound fields in urban squares.
Kang, Jian
2005-06-01
This paper studies the basic characteristics of sound fields in urban squares surrounded by reflecting building façades and the effectiveness of architectural changes and urban design options. A radiosity model and an image source model are developed, and a parametric study is carried out in hypothetical squares. The results show that the reverberation time (RT) is rather even in a square, whereas the early decay time (EDT) is very low in the near field, and then becomes close to RT after a rapid increase. Compared to diffuse boundaries, with geometrical boundaries the RT and EDT are significantly longer and the sound pressure level (SPL) attenuation with distance is generally smaller unless the height/side ratio is high. With a boundary diffusion coefficient of 0.2, the sound field is already close to that resulting from purely diffusely reflecting boundaries. The SPL in far field is typically 6-9 dB lower if the square side is doubled; 8 dB lower if the height of building façades is decreased from 50 m to 6 m (diffuse boundaries); 5 dB (diffuse boundaries) or 2 dB (geometrical boundaries) lower if the length/width ratio is increased from 1 to 4; and 10-12 dB lower if the boundary absorption coefficient is increased from 0.1 to 0.9.
Empirical source noise prediction method with application to subsonic coaxial jet mixing noise
NASA Technical Reports Server (NTRS)
Zorumski, W. E.; Weir, D. S.
1982-01-01
A general empirical method, developed for source noise predictions, uses tensor splines to represent the dependence of the acoustic field on frequency and direction and Taylor's series to represent the dependence on source state parameters. The method is applied to prediction of mixing noise from subsonic circular and coaxial jets. A noise data base of 1/3-octave-band sound pressure levels (SPL's) from 540 tests was gathered from three countries: United States, United Kingdom, and France. The SPL's depend on seven variables: frequency, polar direction angle, and five source state parameters: inner and outer nozzle pressure ratios, inner and outer stream total temperatures, and nozzle area ratio. A least-squares seven-dimensional curve fit defines a table of constants which is used for the prediction method. The resulting prediction has a mean error of 0 dB and a standard deviation of 1.2 dB. The prediction method is used to search for a coaxial jet which has the greatest coaxial noise benefit as compared with an equivalent single jet. It is found that benefits of about 6 dB are possible.
Dundar, Riza; Kulduk, Erkan; Soy, Fatih Kemal; Aslan, Mehmet; Yukkaldiran, Ahmet; Guler, Osman Kadir; Ozbay, Can
2015-06-01
To reveal the success of boomerang-shaped chondroperichondrial graft (BSCPG) in pediatric chronic otitis media cases. A total of 43 pediatric patients (age 7-16 years) who had undergone type 1 tympanoplasty with the diagnosis of chronic otitis media between March 2010 and March 2013 were included in this retrospective study. The main outcome measures were the graft success rate and level of hearing improvement. Graft intake success rate was 90.7%. Mean preoperative and postoperative air-bone gap values were 20.51 ± 4.34 dB SPL and 9.32 ± 5.64 dB SPL, respectively (p < 0.001). Mean preoperative and postoperative pure tone average values were 28.6 ± 3.52 and 12.24 ± 5.22 respectively (p < 0.001). Air-bone gap was improved to ≤ 10 dB in 38 (88.37%) patients during the postoperative period. Boomerang-shaped chondroperichondrial grafting technique seems to be a successful alternative in the management of pediatric chronic otitis media cases. It has relatively higher grade graft success rate. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Moore, Brian C J; Füllgrabe, Christian; Stone, Michael A
2011-01-01
To determine preferred parameters of multichannel compression using individually fitted simulated hearing aids and a method of paired comparisons. Fourteen participants with mild to moderate hearing loss listened via a simulated five-channel compression hearing aid fitted using the CAMEQ2-HF method to pairs of speech sounds (a male talker and a female talker) and musical sounds (a percussion instrument, orchestral classical music, and a jazz trio) presented sequentially and indicated which sound of the pair was preferred and by how much. The sounds in each pair were derived from the same token and differed along a single dimension in the type of processing applied. For the speech sounds, participants judged either pleasantness or clarity; in the latter case, the speech was presented in noise at a 2-dB signal-to-noise ratio. For musical sounds, they judged pleasantness. The parameters explored were time delay of the audio signal relative to the gain control signal (the alignment delay), compression speed (attack and release times), bandwidth (5, 7.5, or 10 kHz), and gain at high frequencies relative to that prescribed by CAMEQ2-HF. Pleasantness increased with increasing alignment delay only for the percussive musical sound. Clarity was not affected by alignment delay. There was a trend for pleasantness to decrease slightly with increasing bandwidth, but this was significant only for female speech with fast compression. Judged clarity was significantly higher for the 7.5- and 10-kHz bandwidths than for the 5-kHz bandwidth for both slow and fast compression and for both talker genders. Compression speed had little effect on pleasantness for 50- or 65-dB SPL input levels, but slow compression was generally judged as slightly more pleasant than fast compression for an 80-dB SPL input level. Clarity was higher for slow than for fast compression for input levels of 80 and 65 dB SPL but not for a level of 50 dB SPL. Preferences for pleasantness were approximately equal with CAMEQ2-HF gains and with gains slightly reduced at high frequencies and were lower when gains were slightly increased at high frequencies. Speech clarity was not affected by changing the gain at high frequencies. Effects of alignment delay were small except for the percussive sound. A wider bandwidth was slightly preferred for speech clarity. Speech clarity was slightly greater with slow compression, especially at high levels. Preferred high-frequency gains were close to or a little below those prescribed by CAMEQ2-HF.
NASA Astrophysics Data System (ADS)
Nobili, R.
2003-02-01
Two years ago, Ruggero et al. [1] focused attention on two curious phenomena regarding the magnitude and phase of tectorial-membrane (TM) vibration relative to basilar-membrane (BM) vibration at a basal site of the chinchilla cochlea: 1) Over a wide range of stimulus frequencies, auditory-nerve responses, which are believed to reflect closely the TM vibration, behave as a linear combination of both BM displacement and velocity. 2) Near threshold, auditory-nerve responses to low-frequency tones are synchronous with peak BM velocity towards scala tympani, but at 80-90 dB SPL and 100-110 dB SPL responses undergo two large phase shifts approaching 180°. Such drastic phase shifts have no counterpart in BM vibrations. Here, it is argued that both these remarkable phenomena have a common origin: the viscoelastic properties of the TM attachment to limbus spiralis.
Sapienza, C M; Crandell, C C; Curtis, B
1999-09-01
Voice problems are a frequent difficulty that teachers experience. Common complaints by teachers include vocal fatigue and hoarseness. One possible explanation for these symptoms is prolonged elevations in vocal loudness within the classroom. This investigation examined the effectiveness of sound-field frequency modulation (FM) amplification on reducing the sound pressure level (SPL) of the teacher's voice during classroom instruction. Specifically, SPL was examined during speech produced in a classroom lecture by 10 teachers with and without the use of sound-field amplification. Results indicated a significant 2.42-dB decrease in SPL with the use of sound-field FM amplification. These data support the use of sound-field amplification in the vocal hygiene regimen recommended to teachers by speech-language pathologists.
Parameters to Maximize 2f2-f1 Distortion Product Otoacoustic Emission Levels
ERIC Educational Resources Information Center
Horn, Jennifer H.; Pratt, Shiela R.; Durrant, John D.
2008-01-01
Purpose: Past research has established parameters for the 2f1-f2 distortion product otoacoustic emissions (DPOAEs) that enhance response levels (e.g., L1 - L2 = 10 dB; f2/f1 = 1.22; L1, L2 = 65, 55 dB SPL). These same parameters do not optimize 2f2-f1 DPOAEs. Therefore, this study was conducted to evaluate more completely those parameters that…
Low noise propeller design using numerical analysis
NASA Astrophysics Data System (ADS)
Humpert, Bryce
The purpose of this study is to explore methods for reducing aircraft propeller noise with minimal losses in performance. Using numerical analysis, a standard two blade propeller configuration was taken from experiments conducted by Patrick, Finn, and Stich, and implemented into the numerical code XROTOR. The blade design modifications that were investigated to achieve the proposed goals include: increasing the number of blades, adjusting the chord length, beta distribution, radius of the blade, airfoil shape, and operating RPM. In order to determine the optimal blade design, a baseline case is first developed and the parameters listed earlier are then varied to create a new propeller design that reduces the sound pressure level (SPL) while maintaining performance levels within a predetermined range of the original specifications. From the analysis, the most significant improvements observed in lowering the acoustic signature are dominated by operating rpm and blade radius. A three-, four-, and five-blade configuration was developed that reduced the SPL generated by the propeller during cruise flight conditions. The optimum configuration that produced the greatest SPL reduction was the five-blade configuration. The resulting sound pressure level was reduced from the original 77 dB at 1000' ft above ground level (AGL), to 54 dB at 1000' AGL while remaining within 1.4% of the original thrust and efficiency.
Darling, Meghan; Huber, Jessica E.
2012-01-01
Purpose Individuals with Parkinson’s disease (PD) exhibit differences in displacement and velocity of the articulators as compared to older adults. The purpose of the current study was to examine effects of three loudness cues on articulatory movement patterns in individuals with PD. Methods Nine individuals diagnosed with idiopathic PD and 9 age- and sex- matched healthy controls produced sentences in four conditions: 1) comfortable loudness, 2) targeting 10dB above comfortable, 3) twice as loud as comfortable, and 4) in background noise. Lip and jaw kinematics and acoustic measurements were obtained. Results Both groups significantly increased sound pressure level (SPL) in the loud conditions as compared to comfortable. For the loud conditions, both groups had the highest SPL in background noise and 10dB and the lowest in twice as loud. Control participants produced the largest opening displacement in background noise and the smallest in twice as loud. Conversely, individuals with PD produced the largest opening displacement in twice as loud and the smallest in background noise. Conclusions Control participants and individuals with PD responded to cues to increase loudness in different ways. Changes in SPL may explain differences in kinematics for the control participants, but do not for individuals with PD. PMID:21386044
Brockmann, Meike; Drinnan, Michael J; Storck, Claudio; Carding, Paul N
2011-01-01
The aims of this study were to examine vowel and gender effects on jitter and shimmer in a typical clinical voice task while correcting for the confounding effects of voice sound pressure level (SPL) and fundamental frequency (F(0)). Furthermore the relative effect sizes of vowel, gender, voice SPL, and F(0) were assessed, and recommendations for clinical measurements were derived. With this cross-sectional single cohort study, 57 healthy adults (28 women, 29 men) aged 20-40 years were investigated. Three phonations of /a/, /o/, and /i/ at "normal" voice loudness were analyzed using Praat (software). The effects of vowel, gender, voice SPL, and F(0) on jitter and shimmer were assessed using descriptive and inferential (analysis of covariance) statistics. The effect sizes were determined with the eta-squared statistic. Vowels, gender, voice SPL, and F(0), each had significant effects either on jitter or on shimmer, or both. Voice SPL was the most important factor, whereas vowel, gender, and F(0) effects were comparatively small. Because men had systematically higher voice SPL, the gender effects on jitter and shimmer were smaller when correcting for SPL and F(0). Surprisingly, in clinical assessments, voice SPL has the single biggest impact on jitter and shimmer. Vowel and gender effects were clinically important, whereas fundamental frequency had a relatively small influence. Phonations at a predefined voice SPL (80 dB minimum) and vowel (/a/) would enhance measurement reliability. Furthermore, gender-specific thresholds applying these guidelines should be established. However, the efficiency of these measures should be verified and tested with patients. Copyright © 2011 The Voice Foundation. All rights reserved.
Laboratory test and acoustic analysis of cabin treatment for propfan test assessment aircraft
NASA Technical Reports Server (NTRS)
Kuntz, H. L.; Gatineau, R. J.
1991-01-01
An aircraft cabin acoustic enclosure, built in support of the Propfan Test Assessment (PTA) program, is described. Helmholtz resonators were attached to the cabin trim panels to increase the sidewall transmission loss (TL). Resonators (448) were located between the trim panels and fuselage shell. In addition, 152 resonators were placed between the enclosure and aircraft floors. The 600 resonators were each tuned to a 235 Hz resonance frequency. After flight testing on the PTA aircraft, the enclosure was tested in the Kelly Johnson R and D Center Acoustics Lab. Laboratory noise reduction (NR) test results are discussed. The enclosure was placed in a Gulfstream 2 fuselage section. Broadband (138 dB overall SPL) and tonal (149 dB overall SPL) excitations were used in the lab. Tonal excitation simulated the propfan flight test excitation. The fundamental tone was stepped in 2 Hz intervals from 225 through 245 Hz. The resonators increase the NR of the cabin walls around the resonance frequency of the resonator array. The effects of flanking, sidewall absorption, cabin adsorption, resonator loading of trim panels, and panel vibrations are presented. Increases in NR of up to 11 dB were measured.
Airborne Acoustic Perception by a Jumping Spider.
Shamble, Paul S; Menda, Gil; Golden, James R; Nitzany, Eyal I; Walden, Katherine; Beatus, Tsevi; Elias, Damian O; Cohen, Itai; Miles, Ronald N; Hoy, Ronald R
2016-11-07
Jumping spiders (Salticidae) are famous for their visually driven behaviors [1]. Here, however, we present behavioral and neurophysiological evidence that these animals also perceive and respond to airborne acoustic stimuli, even when the distance between the animal and the sound source is relatively large (∼3 m) and with stimulus amplitudes at the position of the spider of ∼65 dB sound pressure level (SPL). Behavioral experiments with the jumping spider Phidippus audax reveal that these animals respond to low-frequency sounds (80 Hz; 65 dB SPL) by freezing-a common anti-predatory behavior characteristic of an acoustic startle response. Neurophysiological recordings from auditory-sensitive neural units in the brains of these jumping spiders showed responses to low-frequency tones (80 Hz at ∼65 dB SPL)-recordings that also represent the first record of acoustically responsive neural units in the jumping spider brain. Responses persisted even when the distances between spider and stimulus source exceeded 3 m and under anechoic conditions. Thus, these spiders appear able to detect airborne sound at distances in the acoustic far-field region, beyond the near-field range often thought to bound acoustic perception in arthropods that lack tympanic ears (e.g., spiders) [2]. Furthermore, direct mechanical stimulation of hairs on the patella of the foreleg was sufficient to generate responses in neural units that also responded to airborne acoustic stimuli-evidence that these hairs likely play a role in the detection of acoustic cues. We suggest that these auditory responses enable the detection of predators and facilitate an acoustic startle response. VIDEO ABSTRACT. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Burkard, R.; Jones, S.; Jones, T.
1994-01-01
Rate-dependent changes in the chick brain-stem auditory evoked response (BAER) using conventional averaging and a cross-correlation technique were investigated. Five 15- to 19-day-old white leghorn chicks were anesthetized with Chloropent. In each chick, the left ear was acoustically stimulated. Electrical pulses of 0.1-ms duration were shaped, attenuated, and passed through a current driver to an Etymotic ER-2 which was sealed in the ear canal. Electrical activity from stainless-steel electrodes was amplified, filtered (300-3000 Hz) and digitized at 20 kHz. Click levels included 70 and 90 dB peSPL. In each animal, conventional BAERs were obtained at rates ranging from 5 to 90 Hz. BAERs were also obtained using a cross-correlation technique involving pseudorandom pulse sequences called maximum length sequences (MLSs). The minimum time between pulses, called the minimum pulse interval (MPI), ranged from 0.5 to 6 ms. Two BAERs were obtained for each condition. Dependent variables included the latency and amplitude of the cochlear microphonic (CM), wave 2 and wave 3. BAERs were observed in all chicks, for all level by rate combinations for both conventional and MLS BAERs. There was no effect of click level or rate on the latency of the CM. The latency of waves 2 and 3 increased with decreasing click level and increasing rate. CM amplitude decreased with decreasing click level, but was not influenced by click rate for the 70 dB peSPL condition. For the 90 dB peSPL click, CM amplitude was uninfluenced by click rate for conventional averaging. For MLS BAERs, CM amplitude was similar to conventional averaging for longer MPIs.(ABSTRACT TRUNCATED AT 250 WORDS).
Use of 64-channel electroencephalography to study neural otolith-evoked responses.
McNerney, Kathleen M; Lockwood, Alan H; Coad, Mary Lou; Wack, David S; Burkard, Robert F
2011-03-01
The vestibular evoked myogenic potential (VEMP) is a myogenic response that can be used clinically to evaluate the function of the saccule. However, to date, little is known about the thalamo-cortical representation of saccular activation. It is important to understand all aspects of the VEMP, as this test is currently used clinically in the evaluation of saccular function. To identify the areas of the brain that are activated in response to stimuli used clinically to evoke the VEMP. Electroencephalography (EEG) recordings combined with current density analyses were used to identify the areas of the brain that are activated in response to stimuli presented above VEMP threshold (500 Hz, 120 dB peak SPL [pSPL] tone bursts), as compared to stimuli presented below VEMP threshold (90 dB pSPL, 500 Hz tone bursts). Ten subjects without any history of balance or hearing impairment participated in the study. The neural otolith-evoked responses (NOERs) recorded in response to stimuli presented below VEMP threshold were absent or smaller than NOERs that were recorded in response to stimuli presented above VEMP threshold. Subsequent analyses with source localization techniques, followed by statistical analysis with SPM5 (Statistical Parametric Mapping), revealed several areas that were activated in response to the 120 dB pSPL tone bursts. These areas included the primary visual cortex, the precuneus, the precentral gyrus, the medial temporal gyrus, and the superior temporal gyrus. The present study found a number of specific brain areas that may be activated by otolith stimulation. Given the findings and source localization techniques (which required limited input from the investigator as to where the sources are believed to be located in the brain) used in the present study as well as the similarity in findings between studies employing galvanic stimuli, fMRI (functional magnetic resonance imaging), and scalp-recorded potentials in response to VEMP-eliciting stimuli, our study provides additional evidence that these brain regions are activated in response to stimuli that can be used clinically to evoke the VEMP. American Academy of Audiology.
Hoehmann, D; Müller, S; Dornhoffer, J L
1995-01-01
Low-frequency acoustic biasing using an intensive phase-shifted, low-frequency masker was studied according to its ability to determine disorders of cochlear micromechanics following noise trauma in the guinea pig as animal model. Statistical analyses proved that this technique allowed electrophysiological differentiation of controls versus groups with different degrees of experimentally induced threshold shifts. To substantiate group differences an intensity of at least 70 dB SPL was required for the 52 Hz masker and the difference in relation to the test-tone intensity had to be +/- 10 or +/- 20 dB SPL. The noise-traumatized cochlea could be identified by means of a threshold shift for the 5 microV pseudothreshold, a low modulation span of the compound action potential amplitude (< 25-50 microV frequency dependent), and reduced positive summating potential amplitude with negative non-modulating values within the different measurement phases for 1 and 2 kHz stimulation.
Application of Cortical Processing Theory to Acoustical Analysis
2007-07-27
attenuations of 80 dB. All stimuli were presented binaurally at 60 dB SPL. 4.2 Human performance (see also Appendix B.) Listeners The listeners in all...fepeat - beat vee - bee jt-gtwad_ - rod got - dot Table A.2. A sample of the outcome of one DRT session, one stimulus condition, and one subject. A...to the speech materials binaurally under Sennheiser HD580 headphones. On the first visit, each subject was given a pure tone hearing test to document
Jang, Jongmoon; Lee, JangWoo; Woo, Seongyong; Sly, David J; Campbell, Luke J; Cho, Jin-Ho; O'Leary, Stephen J; Park, Min-Hyun; Han, Sungmin; Choi, Ji-Wong; Jang, Jeong Hun; Choi, Hongsoo
2015-07-31
We proposed a piezoelectric artificial basilar membrane (ABM) composed of a microelectromechanical system cantilever array. The ABM mimics the tonotopy of the cochlea: frequency selectivity and mechanoelectric transduction. The fabricated ABM exhibits a clear tonotopy in an audible frequency range (2.92-12.6 kHz). Also, an animal model was used to verify the characteristics of the ABM as a front end for potential cochlear implant applications. For this, a signal processor was used to convert the piezoelectric output from the ABM to an electrical stimulus for auditory neurons. The electrical stimulus for auditory neurons was delivered through an implanted intra-cochlear electrode array. The amplitude of the electrical stimulus was modulated in the range of 0.15 to 3.5 V with incoming sound pressure levels (SPL) of 70.1 to 94.8 dB SPL. The electrical stimulus was used to elicit an electrically evoked auditory brainstem response (EABR) from deafened guinea pigs. EABRs were successfully measured and their magnitude increased upon application of acoustic stimuli from 75 to 95 dB SPL. The frequency selectivity of the ABM was estimated by measuring the magnitude of EABRs while applying sound pressure at the resonance and off-resonance frequencies of the corresponding cantilever of the selected channel. In this study, we demonstrated a novel piezoelectric ABM and verified its characteristics by measuring EABRs.
MEMS capacitive accelerometer-based middle ear microphone.
Young, Darrin J; Zurcher, Mark A; Semaan, Maroun; Megerian, Cliff A; Ko, Wen H
2012-12-01
The design, implementation, and characterization of a microelectromechanical systems (MEMS) capacitive accelerometer-based middle ear microphone are presented in this paper. The microphone is intended for middle ear hearing aids as well as future fully implantable cochlear prosthesis. Human temporal bones acoustic response characterization results are used to derive the accelerometer design requirements. The prototype accelerometer is fabricated in a commercial silicon-on-insulator (SOI) MEMS process. The sensor occupies a sensing area of 1 mm × 1 mm with a chip area of 2 mm × 2.4 mm and is interfaced with a custom-designed low-noise electronic IC chip over a flexible substrate. The packaged sensor unit occupies an area of 2.5 mm × 6.2 mm with a weight of 25 mg. The sensor unit attached to umbo can detect a sound pressure level (SPL) of 60 dB at 500 Hz, 35 dB at 2 kHz, and 57 dB at 8 kHz. An improved sound detection limit of 34-dB SPL at 150 Hz and 24-dB SPL at 500 Hz can be expected by employing start-of-the-art MEMS fabrication technology, which results in an articulation index of approximately 0.76. Further micro/nanofabrication technology advancement is needed to enhance the microphone sensitivity for improved understanding of normal conversational speech.
Schulze, W; Schul, J
2001-02-01
The responses of female Tettigonia viridissima to simulated bat echolocation calls were examined during tethered flight. The insects responded with three distinct behaviours, which occurred at graded stimulus intensities. At low intensities (threshold 54 dB SPL), T. viridissima responded by steering away from the sound source (negative phonotaxis). At intensities approximately 10 dB higher, beating of the hindwing was interrupted, although the insect remained in the flight posture. A diving response (cessation of the wingbeat, closure of the forewings and alignment of the legs against the body) occurred with a threshold of 76 dB SPL. Considering these thresholds, we estimate that the diving response occurs at approximately the sound amplitude at which many aerial-hawking bats first receive echoes from the insect. The other behaviours probably occur before the bat detects the insect and should therefore be interpreted as early avoidance behaviours. The repertoire of startle responses in T. viridissima, with directional and non-directional components, is similar to those of crickets and moths, but quite different from those described for another bushcricket (Neoconocephalus ensiger), which shows only a non-directional response. This supports the conclusion that bat-evasive behaviours are not conserved within the Tettigoniidae, but instead are shaped by the ecological constraints of the insects.
Normative data for the Words-in-Noise Test for 6- to 12-year-old children.
Wilson, Richard H; Farmer, Nicole M; Gandhi, Avni; Shelburne, Emily; Weaver, Jamie
2010-10-01
To establish normative data for children on the Words-in-Noise Test (WIN; R. H. Wilson, 2003; R. H. Wilson & R. McArdle, 2007). Forty-two children in each of 7 age groups, ranging in age from 6 to 12 years (n=294), and 24 young adults (age range: 18-27 years) with normal hearing for pure tones participated. All listeners were screened at 15 dB HL (American National Standards Institute, 2004) with the octave interval between 500 and 4000 Hz. Randomizations of WIN Lists 1, 2, and 1 or WIN Lists 2, 1, and 2 were presented with the noise fixed at 70 dB SPL, followed by presentation at 90 dB SPL of the 70 Northwestern University Auditory Test No. 6 (T. W. Tillman & R. Carhart, 1966) words used in the WIN. Finally, the Peabody Picture Vocabulary Test-Revised (L. M. Dunn & L. M. Dunn, 1981) was administered. Testing was conducted in a quiet room. There were 3 main findings: (a) The biggest change in recognition performance occurred between the ages of 6 and 7 years; (b) from 9 to 12 years, recognition performance was stable; and (c) performance by young adults (18-27 years) was slightly better (1-2 dB) than performance by the older children. The WIN can be used with children as young as 6 years of age; however, age-specific ranges of normal recognition performance must be used.
NASA Astrophysics Data System (ADS)
Mills, David M.
2003-02-01
Characteristics of distortion product otoacoustic emissions (DPOAEs) and auditory brainstem responses (ABRs) were measured in Mongolian gerbil before and after the introduction of two different auditory dysfunctions: (1) acoustic damage with a high-intensity tone, or (2) furosemide intoxication. The goal was to find emission parameters and measures that best differentiated between the two dysfunctions, e.g., at a given ABR threshold elevation. Emission input-output or ``growth'' functions were used (frequencies f1 and f2, f2/f1=1.21) with equal levels, L1=L2, and unequal levels, with L1=L2+20 dB. The best parametric choice was found to be unequal stimulus levels, and the best measure was found to be the change in the emission threshold level, Δx. The emission threshold was defined as the stimulus level required to reach a criterion emission amplitude, in this case -10 dB SPL. (The next best measure was the change in emission amplitude at high stimulus levels, specifically that measured at L1×L2=90×70 dB SPL.) For an ABR threshold shift of 20 dB or more, there was essentially no overlap in the emission threshold measures for the two conditions, sound damage or furosemide. The dividing line between the two distributions increased slowly with the change in ABR threshold, ΔABR, and was given by Δxt=0.6 ΔABR+8 dB. For a given ΔABR, if the shift in emission threshold was more than the calculated dividing line value, Δxt, the auditory dysfunction was due to acoustic damage, if less, it was due to furosemide.
A numerical study of the acoustic radiation due to eddy current-cryostat interactions.
Wang, Yaohui; Liu, Feng; Zhou, Xiaorong; Li, Yu; Crozier, Stuart
2017-06-01
To investigate the acoustic radiation due to eddy current-cryostat interactions and perform a qualitative analysis on noise reduction methods. In order to evaluate the sound pressure level (SPL) of the eddy current induced warm bore wall vibration, a Finite Element (FE) model was created to simulate the noises from both the warm bore wall vibration and the gradient coil assembly. For the SPL reduction of the warm bore wall vibration, we first improved the active shielding of the gradient coil, thus reducing the eddy current on the warm bore wall. A damping treatment was then applied to the warm bore wall to control the acoustic radiation. Initial simulations show that the SPL of the warm bore wall is higher than that of the gradient assembly with typical design shielding ratios at many frequencies. Subsequent simulation results of eddy current control and damping treatment application show that the average SPL reduction of the warm bore wall can be as high as 9.6 dB, and even higher in some frequency bands. Combining eddy current control and suggested damping scheme, the noise level in a MRI system can be effectively reduced. © 2017 American Association of Physicists in Medicine.
Roberts, Louise; Pérez-Domínguez, Rafael; Elliott, Michael
2016-11-15
Free-ranging individual fish were observed using a baited remote underwater video (BRUV) system during sound playback experiments. This paper reports on test trials exploring BRUV design parameters, image analysis and practical experimental designs. Three marine species were exposed to playback noise, provided as examples of behavioural responses to impulsive sound at 163-171dB re 1μPa (peak-to-peak SPL) and continuous sound of 142.7dB re 1μPa (RMS, SPL), exhibiting directional changes and accelerations. The methods described here indicate the efficacy of BRUV to examine behaviour of free-ranging species to noise playback, rather than using confinement. Given the increasing concern about the effects of water-borne noise, for example its inclusion within the EU Marine Strategy Framework Directive, and the lack of empirical evidence in setting thresholds, this paper discusses the use of BRUV, and short term behavioural changes, in supporting population level marine noise management. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reliability of measures of transient evoked otoacoustic emissions with contralateral suppression.
Stuart, Andrew; Cobb, Kensi M
2015-01-01
The reliability of measures of transient evoked otoacoustic emissions (TEOAEs) with contralateral suppression was examined. The effect of test session (i.e., initial test; retest without probe removal; retest with probe removal; and retest 1-2 days post initial test), gender, and ear was examined in 14 young adult females and 14 young adult males. TEOAEs were obtained bilaterally with 60 dB peSPL linear click stimuli with and without a contralateral 65 dB SPL broadband noise suppressor. Absolute TEOAE suppression and a normalized index of TEOAE suppression (i.e., percentage of suppression) were examined. Reliability of these measures was assessed with repeated measures linear mixed model analysis of variance, a coefficient of reliability, and Bland-Altman analyses. There were no statistically significant (p>0.05) main effects of test, gender, and ear or interactions for both absolute dB and % TEOAE suppression values. Cronbach's α were greater than 0.90 across the four tests for both TEOAE measures. Mean test differences or bias (i.e., between the initial and subsequent tests) for absolute and % TEOAE suppression ranged from -0.05 to 0.11 dB and -1.5% to 1.1%, respectively. There was no proportional/systematic bias with the mean differences of the first and subsequent measurements. Data herein were consistent with the view that bilateral TEOAE suppression measures are reliable across test sessions of 1-2 days among females and males and may provide a method to monitor medial olivocochlear efferent reflex status over time. Copyright © 2015 Elsevier Inc. All rights reserved.
The influence of jet engine noise on hearing of technical staff.
Konopka, Wiesław; Pawlaczyk-Luszczyńska, Małgorzata; Śliwińska-Kowalska, Mariola
2014-01-01
Due to high sound pressure levels (SPLs), noise produced by jet planes may be harmful to hearing of people working in their proximity. The aim of this study was to assess the effects of exposure to jet engine noise on technical staff hearing. The study comprised 60 men, aged 24-50 years, employed in army as technical staff and exposed to jet engine noise for 6-20 years. The control group were 50 non-noise exposed males, aged 25-51 years. Exposure to noise emitted by jet engines was evaluated. Pure-tone audiometry (PTA) and distortion product otoacoustic emissions (DPOAE) were recorded in both groups. Jet engines emitted broadband noise with spectrum dominated by components in the frequency range 315-6300 Hz (1/3-octave bands). Maximum A-weighted SPL during tests reached values of approx. 120-130 dB. Consequently, engine-servicing personnel (even in the case of a single engine test) was exposed to noise (at A-weighted daily noise exposure level above 95 dB) exceeding permissible levels. Averaged audiometric hearing threshold levels of technical staff were higher (≤ 17 dB HL, p < 0.001) than in the control group. Similarly, the DPOAE amplitude was lower (≤ 17 dB SPL, p < 0.01) in the noise-exposed subjects compared to the non-exposed ones. Significant reduction of DPOAE levels was mainly noted for high frequencies (3-6 kHz). Despite the usage of hearing protection devices, both PTA and DPOAE consistently showed poorer hearing in engine-servicing personnel vs. control group.
Swept-sine noise-induced damage as a hearing loss model for preclinical assays
Sanz, Lorena; Murillo-Cuesta, Silvia; Cobo, Pedro; Cediel-Algovia, Rafael; Contreras, Julio; Rivera, Teresa; Varela-Nieto, Isabel; Avendaño, Carlos
2015-01-01
Mouse models are key tools for studying cochlear alterations in noise-induced hearing loss (NIHL) and for evaluating new therapies. Stimuli used to induce deafness in mice are usually white and octave band noises that include very low frequencies, considering the large mouse auditory range. We designed different sound stimuli, enriched in frequencies up to 20 kHz (“violet” noises) to examine their impact on hearing thresholds and cochlear cytoarchitecture after short exposure. In addition, we developed a cytocochleogram to quantitatively assess the ensuing structural degeneration and its functional correlation. Finally, we used this mouse model and cochleogram procedure to evaluate the potential therapeutic effect of transforming growth factor β1 (TGF-β1) inhibitors P17 and P144 on NIHL. CBA mice were exposed to violet swept-sine noise (VS) with different frequency ranges (2–20 or 9–13 kHz) and levels (105 or 120 dB SPL) for 30 min. Mice were evaluated by auditory brainstem response (ABR) and otoacoustic emission tests prior to and 2, 14 and 28 days after noise exposure. Cochlear pathology was assessed with gross histology; hair cell number was estimated by a stereological counting method. Our results indicate that functional and morphological changes induced by VS depend on the sound level and frequency composition. Partial hearing recovery followed the exposure to 105 dB SPL, whereas permanent cochlear damage resulted from the exposure to 120 dB SPL. Exposure to 9–13 kHz noise caused an auditory threshold shift (TS) in those frequencies that correlated with hair cell loss in the corresponding areas of the cochlea that were spotted on the cytocochleogram. In summary, we present mouse models of NIHL, which depending on the sound properties of the noise, cause different degrees of cochlear damage, and could therefore be used to study molecules which are potential players in hearing loss protection and repair. PMID:25762930
Acoustic agglomeration of fine particles based on a high intensity acoustical resonator
NASA Astrophysics Data System (ADS)
Zhao, Yun; Zeng, Xinwu; Tian, Zhangfu
2015-10-01
Acoustic agglomeration (AA) is considered to be a promising method for reducing the air pollution caused by fine aerosol particles. Removal efficiency and energy consuming are primary parameters and generally have a conflict with each other for the industry applications. It was proved that removal efficiency is increased with sound intensity and optimal frequency is presented for certain polydisperse aerosol. As a result, a high efficiency and low energy cost removal system was constructed using acoustical resonance. High intensity standing wave is generated by a tube system with abrupt section driven by four loudspeakers. Numerical model of the tube system was built base on the finite element method, and the resonance condition and SPL increase were confirmd. Extensive tests were carried out to investigate the acoustic field in the agglomeration chamber. Removal efficiency of fine particles was tested by the comparison of filter paper mass and particle size distribution at different operating conditions including sound pressure level (SPL), and frequency. The experimental study has demonstrated that agglomeration increases with sound pressure level. Sound pressure level in the agglomeration chamber is between 145 dB and 165 dB from 500 Hz to 2 kHz. The resonance frequency can be predicted with the quarter tube theory. Sound pressure level gain of more than 10 dB is gained at resonance frequency. With the help of high intensity sound waves, fine particles are reduced greatly, and the AA effect is enhanced at high SPL condition. The optimal frequency is 1.1kHz for aerosol generated by coal ash. In the resonace tube, higher resonance frequencies are not the integral multiplies of the first one. As a result, Strong nonlinearity is avoided by the dissonant characteristic and shock wave is not found in the testing results. The mechanism and testing system can be used effectively in industrial processes in the future.
Cortical Auditory Evoked Potentials in (Un)aided Normal-Hearing and Hearing-Impaired Adults
Van Dun, Bram; Kania, Anna; Dillon, Harvey
2016-01-01
Cortical auditory evoked potentials (CAEPs) are influenced by the characteristics of the stimulus, including level and hearing aid gain. Previous studies have measured CAEPs aided and unaided in individuals with normal hearing. There is a significant difference between providing amplification to a person with normal hearing and a person with hearing loss. This study investigated this difference and the effects of stimulus signal-to-noise ratio (SNR) and audibility on the CAEP amplitude in a population with hearing loss. Twelve normal-hearing participants and 12 participants with a hearing loss participated in this study. Three speech sounds—/m/, /g/, and /t/—were presented in the free field. Unaided stimuli were presented at 55, 65, and 75 dB sound pressure level (SPL) and aided stimuli at 55 dB SPL with three different gains in steps of 10 dB. CAEPs were recorded and their amplitudes analyzed. Stimulus SNRs and audibility were determined. No significant effect of stimulus level or hearing aid gain was found in normal hearers. Conversely, a significant effect was found in hearing-impaired individuals. Audibility of the signal, which in some cases is determined by the signal level relative to threshold and in other cases by the SNR, is the dominant factor explaining changes in CAEP amplitude. CAEPs can potentially be used to assess the effects of hearing aid gain in hearing-impaired users. PMID:27587919
Evaluation of the Repeatability and Accuracy of the Wideband Real-Ear-to-Coupler Difference.
Vaisberg, Jonathan M; Folkeard, Paula; Pumford, John; Narten, Philipp; Scollie, Susan
2018-06-01
The real-ear-to-coupler difference (RECD) is an ANSI standardized method for estimating ear canal sound pressure level (SPL) thresholds and assisting in the prediction of real-ear aided responses. It measures the difference in dB between the SPL produced in the ear canal and the SPL produced in an HA-1 2-cc coupler by the same sound source. Recent evidence demonstrates that extended high-frequency bandwidth, beyond the hearing aid bandwidth typically measured, is capable of providing additional clinical benefit. The industry has, in turn, moved toward developing hearing aids and verification equipment capable of producing and measuring extended high-frequency audible output. As a result, a revised RECD procedure conducted using a smaller, 0.4-cc coupler, known as the wideband-RECD (wRECD), has been introduced to facilitate extended high-frequency coupler-based measurements up to 12.5 kHz. This study aimed to (1) compare test-retest repeatability between the RECD and wRECD and (2) measure absolute agreement between the RECD and wRECD when both are referenced to a common coupler. RECDs and wRECDs were measured bilaterally in adult ears by calculating the dB difference in SPL between the ear canal and coupler responses. Real-ear probe microphone measures were completed twice per ear per participant for both foam-tip and customized earmold couplings using the Audioscan Verifit 1 and Verifit 2 fitting systems, followed by measurements in the respective couplers. Twenty-one adults (mean age = 67 yr, range = 19-78) with typical aural anatomy (as determined by measures of impedance and otoscopy) participated in this study, leading to a sample size of 42 ears. Repeatability within RECD and wRECD was assessed for each coupling configuration using a repeated-measures analysis of variance (ANOVA) with test-retest and frequency as within-participants factors. Repeatability between the RECD and wRECD was assessed within each configuration using a repeated-measures ANOVA with test-retest, frequency, and coupler type as within-participants factors. Agreement between the RECD and wRECD was assessed for each coupling configuration using a repeated-measures ANOVA with RECD value, coupler type, and frequency as within-participants factors. Post hoc comparisons with Bonferroni corrections were used when appropriate to locate the frequencies at which differences occurred. A 3-dB criterion was defined to locate differences of clinical significance. Average absolute test-retest differences were within ±3 dB within each coupler and coupling configuration, and between the RECD and wRECD. The RECD and wRECD were in absolute agreement following HA-1-referenced transforms, with most frequencies agreeing within ±1 dB, except at 0.2 kHz for the earmold, and 0.2-0.25 kHz for the foam tip, where the average RECD exceeded the average wRECD by slightly >3 dB. Test-retest repeatability of the RECD (up to 8 kHz) and wRECD (up to 12.5 kHz) is acceptable and similar to previously reported data. The RECD and wRECD are referenced to different couplers, but can be rendered comparable with a simple transform, producing values that are in accordance with the ANSI S3.46-2013 standard. American Academy of Audiology.
Contralateral Dpoae Suppression in Humans at Very Low Sound Intensities
NASA Astrophysics Data System (ADS)
Janssen, T.; Gehr, D. D.; Kevanishvili, Z.
2003-02-01
Different functions are attributed to the olivo-cochlear bundle system (OCBS) such as protecting the ear from acoustic injury, improving signal detection in noise, and mediating selective attention. OCBS reflex strength can be evaluated, in animals as well as in humans, by measuring the degree of suppression of an ipsilateral DPOAE by a contralateral sound. The purpose of the study was to evaluate OCBS reflex strength depending on ipsilateral stimulus level, especially at threshold, by means of extrapolated DPOAE I/O-functions. Additionally, DPOAE was measured at near-to-threshold contralateral stimulus levels when using low-level ipsilateral stimulation for investigating possible enhancement of outer hair cell motion in the presence of low-level contralateral sound. The recording of the 2f1-f2 DPOAE in the presence or absence of contralateral sound was performed in normally hearing human subjects at f2 = 2 kHz. DPOAE I/O-functions were measured in a primary tone level range from L2 = 20 to L2 = 65 dB SPL (L1 = 0.4L2 + 39, f2/f1=1.2). Broad-band noise (BBN), narrow-band noise from 1720 to 2320 Hz (NBN), and pure tones (PT) at f2, 2f1-f2, geometric mean of f1 and f2, and 0.1oct + f2 were used for contralateral stimulation. The contralateral stimulus level (Ls) was decreased from 70 down to 10 dB SPL in 10 dB steps. DPOAE suppression was highest at the lowest primary tone level and was more pronounced for BBN and NBN than for pure tones, suggesting a more diffuse than a strong tonotopic organisation of the OCBS. The contralateral stimulus level at which significant DPOAE suppression occurred (p < 0.05) was different for the different stimuli being 20, 40, and 70 dB SPL for BBN, NBN, and pure-tone (f2), respectively. Significant DPOAE suppression to BBN and NBN occurred at Ls well below audiological middle-ear reflex threshold. DPOAE time course was different for Ls below and above middle-ear reflex threshold. Thus, middle-ear muscle contraction is suggested not to be involved in DPOAE suppression at low Ls. No enhancement of DPOAE could be found. The findings suggest the OCBS to be functioning in a more protective way than for improving signal detection in noise.
Lamm, K; Lamm, C; Lamm, H; Schumann, K
1988-09-01
In 14 guinea pigs the pO2 in the perilymph of the scala tympani fell to 50%-80% of the original value during exposure to noise consisting of 4,000 Hz clicks with a repetition rate of 20/s, 100 dB CHL = 120 dB SPL p.e., repeated twice over a period of 24 minutes each time. For the measurements of the pO2 we used the thin 0.5 micron micro-coaxial needle electrode described by Baumgärtl and Luebbers, which was placed through the round-window membrane in the scala tympani to a depth of 600 micron. The simultaneously recorded CAP latency times were prolonged by 0.8 ms at a test loudness of 60 and 80 dB CHL. The amplitudes of the CM had declined by 60%-70% of the original values at a test loudness of 80 dB SPL p.e. The intra-arterial blood pressure in the common carotid artery of all animals remained constant. As the cortilymph spaces communicate with the perilymph of the scala tympani, our measured decline of pO2 in the perilymph could indicate a cortilymph hypoxia. During exposure to noise the oxygen-dependent Na+ and K+ pumps, which maintain the ion balance and function of the organ of Corti, can decompensate due to lack of oxygen. That would lead to a K+ contamination of the cortilymph and to an intracellular Na+ accumulation, which can cause microstructural damage (hair cell-cilia fusion, hair cell, synaptic and dendritic swelling, hair cell contraction and sustained depolarization), which would be reflected in the CMs and CAPs.
The MOC Reflex during Active Listening to Speech
ERIC Educational Resources Information Center
Garinis, Angela C.; Glattke, Theodore; Cone, Barbara K.
2011-01-01
Purpose: The purpose of this study was to test the hypothesis that active listening to speech would increase medial olivocochlear (MOC) efferent activity for the right vs. the left ear. Method: Click-evoked otoacoustic emissions (CEOAEs) were evoked by 60-dB p.e. SPL clicks in 13 normally hearing adults in 4 test conditions for each ear: (a) in…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-13
... specified activity that cannot be reasonably expected to, and is not reasonably likely to, adversely affect... received SPL of 120 dB (rms) re 1 [mu]Pa, a level thought may cause Level B behavioral harassment to marine... porpoises. However, lower frequency man-made noises are more likely to affect detection of communication...
Zhai, S-Q; Guo, W; Hu, Y-Y; Yu, N; Chen, Q; Wang, J-Z; Fan, M; Yang, W-Y
2011-05-01
To explore the protective effects of brain-derived neurotrophic factor on the noise-damaged cochlear spiral ganglion. Recombinant adenovirus brain-derived neurotrophic factor vector, recombinant adenovirus LacZ and artificial perilymph were prepared. Guinea pigs with audiometric auditory brainstem response thresholds of more than 75 dB SPL, measured seven days after four hours of noise exposure at 135 dB SPL, were divided into three groups. Adenovirus brain-derived neurotrophic factor vector, adenovirus LacZ and perilymph were infused into the cochleae of the three groups, variously. Eight weeks later, the cochleae were stained immunohistochemically and the spiral ganglion cells counted. The auditory brainstem response threshold recorded before and seven days after noise exposure did not differ significantly between the three groups. However, eight weeks after cochlear perfusion, the group receiving brain-derived neurotrophic factor had a significantly decreased auditory brainstem response threshold and increased spiral ganglion cell count, compared with the adenovirus LacZ and perilymph groups. When administered via cochlear infusion following noise damage, brain-derived neurotrophic factor appears to improve the auditory threshold, and to have a protective effect on the spiral ganglion cells.
Loudness perception and speech intensity control in Parkinson's disease.
Clark, Jenna P; Adams, Scott G; Dykstra, Allyson D; Moodie, Shane; Jog, Mandar
2014-01-01
The aim of this study was to examine loudness perception in individuals with hypophonia and Parkinson's disease. The participants included 17 individuals with hypophonia related to Parkinson's disease (PD) and 25 age-equivalent controls. The three loudness perception tasks included a magnitude estimation procedure involving a sentence spoken at 60, 65, 70, 75 and 80 dB SPL, an imitation task involving a sentence spoken at 60, 65, 70, 75 and 80 dB SPL, and a magnitude production procedure involving the production of a sentence at five different loudness levels (habitual, two and four times louder and two and four times quieter). The participants with PD produced a significantly different pattern and used a more restricted range than the controls in their perception of speech loudness, imitation of speech intensity, and self-generated estimates of speech loudness. The results support a speech loudness perception deficit in PD involving an abnormal perception of externally generated and self-generated speech intensity. Readers will recognize that individuals with hypophonia related to Parkinson's disease may demonstrate a speech loudness perception deficit involving the abnormal perception of externally generated and self-generated speech intensity. Copyright © 2014 Elsevier Inc. All rights reserved.
Borch, D Zangger; Sundberg, J; Lindestad, P A; Thalén, M
2004-01-01
The acoustic characteristics of so-called 'dist' tones, commonly used in singing rock music, are analyzed in a case study. In an initial experiment a professional rock singer produced examples of 'dist' tones. The tones were found to contain aperiodicity, SPL at 0.3 m varied between 90 and 96 dB, and subglottal pressure varied in the range of 20-43 cm H2O, a doubling yielding, on average, an SPL increase of 2.3 dB. In a second experiment, the associated vocal fold vibration patterns were recorded by digital high-speed imaging of the same singer. Inverse filtering of the simultaneously recorded audio signal showed that the aperiodicity was caused by a low frequency modulation of the flow glottogram pulse amplitude. This modulation was produced by an aperiodic or periodic vibration of the supraglottic mucosa. This vibration reduced the pulse amplitude by obstructing the airway for some of the pulses produced by the apparently periodically vibrating vocal folds. The supraglottic mucosa vibration can be assumed to be driven by the high airflow produced by the elevated subglottal pressure.
Hearing and spatial behavior in Gryllotalpa major Saussure (Orthoptera: Gryllotalpidae).
Howard, Daniel R; Mason, Andrew C; Hill, Peggy S M
2008-11-01
The prairie mole cricket (Gryllotalpa major Saussure) is a rare orthopteran insect of the tallgrass prairie ecosystem of the south central USA. Populations are known to currently occupy fragmented prairie sites in Oklahoma, Arkansas, Kansas and Missouri, including The Nature Conservancy's Tallgrass Prairie Preserve in north central Oklahoma. Prairie mole cricket populations were surveyed at this site and at another site in Craig County, OK during the spring of 2005 and 2006, using the male cricket's acoustic call to locate advertising aggregations of males. Five males from one large aggregation were removed in a study to describe (1) the hearing thresholds across the call's range of frequencies, (2) the distances over which the higher harmonic components of the male's calls are potentially detectable, (3) the species' sensitivity to ultrasound and (4) the spatio-auditory dynamics of the prairie mole cricket lek. Results indicate that G. major has a bimodal pattern of frequency tuning, with hearing sensitivities greatest at the 2 kHz carrier frequency (41 dB SPL) and declining through the call's frequency range (84 dB at 10 kHz). A second sensitivity peak is evident in the ultrasound range at 25 kHz (62 dB SPL). Spatial analysis of G. major lek sites indicates that approximately 73% of males within the lek are spaced in such a way as to allow acoustic interaction at the species' carrier frequency, while any information in higher harmonic overtones in the call appears to be available only to nearest neighbors.
Khan, Farid Ullah; Khattak, Muhammad Umair
2016-02-01
Rapid developments in micro electronics, micro fabrication, ultra-large scale of integration, ultra-low power sensors, and wireless technology have greatly reduced the power consumption requirements of wireless sensor nodes (WSNs) and make it possible to operate these devices with energy harvesters. Likewise, other energy harvesters, acoustic energy harvesters (AEHs), have been developed and are gaining swift interest in last few years. This paper presents a review of AEHs reported in the literature for the applications of WSNs. Based on transduction mechanism, there are two types of AEHs: piezoelectric acoustic energy harvesters (PEAEHs) and electromagnetic acoustic energy harvesters (EMAEHs). The reported AEHs are mostly characterized under the sound pressure level (SPL) that ranges from 45 to 161 dB. The range for resonant frequency of the produced AEHs is from 146 Hz to 24 kHz and these produced 0.68 × 10(-6) μW to 30 mW power. The maximum power (30 mW) is produced by a PEAEH, when the harvester is subjected to a SPL of 161 dB and 2.64 kHz frequency. However, for EMAEHs, the maximum power reported is about 1.96 mW (at 125 dB and 143 Hz). Under the comparable SPLs, the power production by the reported EMAEHs is relatively better than that of PEAEHs, moreover, due to lower resonant frequency, the EMAEHs are more feasible for the low frequency band acoustical environment.
NASA Astrophysics Data System (ADS)
Khan, Farid Ullah; Khattak, Muhammad Umair
2016-02-01
Rapid developments in micro electronics, micro fabrication, ultra-large scale of integration, ultra-low power sensors, and wireless technology have greatly reduced the power consumption requirements of wireless sensor nodes (WSNs) and make it possible to operate these devices with energy harvesters. Likewise, other energy harvesters, acoustic energy harvesters (AEHs), have been developed and are gaining swift interest in last few years. This paper presents a review of AEHs reported in the literature for the applications of WSNs. Based on transduction mechanism, there are two types of AEHs: piezoelectric acoustic energy harvesters (PEAEHs) and electromagnetic acoustic energy harvesters (EMAEHs). The reported AEHs are mostly characterized under the sound pressure level (SPL) that ranges from 45 to 161 dB. The range for resonant frequency of the produced AEHs is from 146 Hz to 24 kHz and these produced 0.68 × 10-6 μW to 30 mW power. The maximum power (30 mW) is produced by a PEAEH, when the harvester is subjected to a SPL of 161 dB and 2.64 kHz frequency. However, for EMAEHs, the maximum power reported is about 1.96 mW (at 125 dB and 143 Hz). Under the comparable SPLs, the power production by the reported EMAEHs is relatively better than that of PEAEHs, moreover, due to lower resonant frequency, the EMAEHs are more feasible for the low frequency band acoustical environment.
On the accurate analysis of vibroacoustics in head insert gradient coils.
Winkler, Simone A; Alejski, Andrew; Wade, Trevor; McKenzie, Charles A; Rutt, Brian K
2017-10-01
To accurately analyze vibroacoustics in MR head gradient coils. A detailed theoretical model for gradient coil vibroacoustics, including the first description and modeling of Lorentz damping, is introduced and implemented in a multiphysics software package. Numerical finite-element method simulations were used to establish a highly accurate vibroacoustic model in head gradient coils in detail, including the newly introduced Lorentz damping effect. Vibroacoustic coupling was examined through an additional modal analysis. Thorough experimental studies were used to validate simulations. Average experimental sound pressure levels (SPLs) and accelerations over the 0-3000 Hz frequency range were 97.6 dB, 98.7 dB, and 95.4 dB, as well as 20.6 g, 8.7 g, and 15.6 g for the X-, Y-, and Z-gradients, respectively. A reasonable agreement between simulations and measurements was achieved. Vibroacoustic coupling showed a coupled resonance at 2300 Hz for the Z-gradient that is responsible for a sharp peak and the highest SPL value in the acoustic spectrum. We have developed and used more realistic multiphysics simulation methods to gain novel insights into the underlying concepts for vibroacoustics in head gradient coils, which will permit improved analyses of existing gradient coils and novel SPL reduction strategies for future gradient coil designs. Magn Reson Med 78:1635-1645, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Contralateral Inhibition of Click- and Chirp-Evoked Human Compound Action Potentials
Smith, Spencer B.; Lichtenhan, Jeffery T.; Cone, Barbara K.
2017-01-01
Cochlear outer hair cells (OHC) receive direct efferent feedback from the caudal auditory brainstem via the medial olivocochlear (MOC) bundle. This circuit provides the neural substrate for the MOC reflex, which inhibits cochlear amplifier gain and is believed to play a role in listening in noise and protection from acoustic overexposure. The human MOC reflex has been studied extensively using otoacoustic emissions (OAE) paradigms; however, these measurements are insensitive to subsequent “downstream” efferent effects on the neural ensembles that mediate hearing. In this experiment, click- and chirp-evoked auditory nerve compound action potential (CAP) amplitudes were measured electrocochleographically from the human eardrum without and with MOC reflex activation elicited by contralateral broadband noise. We hypothesized that the chirp would be a more optimal stimulus for measuring neural MOC effects because it synchronizes excitation along the entire length of the basilar membrane and thus evokes a more robust CAP than a click at low to moderate stimulus levels. Chirps produced larger CAPs than clicks at all stimulus intensities (50–80 dB ppeSPL). MOC reflex inhibition of CAPs was larger for chirps than clicks at low stimulus levels when quantified both in terms of amplitude reduction and effective attenuation. Effective attenuation was larger for chirp- and click-evoked CAPs than for click-evoked OAEs measured from the same subjects. Our results suggest that the chirp is an optimal stimulus for evoking CAPs at low stimulus intensities and for assessing MOC reflex effects on the auditory nerve. Further, our work supports previous findings that MOC reflex effects at the level of the auditory nerve are underestimated by measures of OAE inhibition. PMID:28420960
A Comparison of Presentation Levels to Maximize Word Recognition Scores
Guthrie, Leslie A.; Mackersie, Carol L.
2010-01-01
Background While testing suprathreshold word recognition at multiple levels is considered best practice, studies on practice patterns do not suggest that this is common practice. Audiologists often test at a presentation level intended to maximize recognition scores, but methods for selecting this level are not well established for a wide range of hearing losses. Purpose To determine the presentation level methods that resulted in maximum suprathreshold phoneme-recognition scores while avoiding loudness discomfort. Research Design Performance-intensity functions were obtained for 40 participants with sensorineural hearing loss using the Computer-Assisted Speech Perception Assessment. Participants had either gradually sloping (mild, moderate, moderately severe/severe) or steeply sloping losses. Performance-intensity functions were obtained at presentation levels ranging from 10 dB above the SRT to 5 dB below the UCL (uncomfortable level). In addition, categorical loudness ratings were obtained across a range of intensities using speech stimuli. Scores obtained at UCL – 5 dB (maximum level below loudness discomfort) were compared to four alternative presentation-level methods. The alternative presentation-level methods included sensation level (SL; 2 kHz reference, SRT reference), a fixed-level (95 dB SPL) method, and the most comfortable loudness level (MCL). For the SL methods, scores used in the analysis were selected separately for the SRT and 2 kHz references based on several criteria. The general goal was to choose levels that represented asymptotic performance while avoiding loudness discomfort. The selection of SLs varied across the range of hearing losses. Results Scores obtained using the different presentation-level methods were compared to scores obtained using UCL – 5 dB. For the mild hearing loss group, the mean phoneme scores were similar for all presentation levels. For the moderately severe/severe group, the highest mean score was obtained using UCL - 5 dB. For the moderate and steeply sloping groups, the mean scores obtained using 2 kHz SL were equivalent to UCL - 5 dB, whereas scores obtained using the SRT SL were significantly lower than those obtained using UCL - 5 dB. The mean scores corresponding to MCL and 95 dB SPL were significantly lower than scores for UCL - 5 dB for the moderate and the moderately severe/severe group. Conclusions For participants with mild to moderate gradually sloping losses and for those with steeply sloping losses, the UCL – 5 dB and the 2 kHz SL methods resulted in the highest scores without exceeding listeners' UCLs. For participants with moderately severe/severe losses, the UCL - 5 dB method resulted in the highest phoneme recognition scores. PMID:19594086
Development of a FDA-Approved Pharmaceutical to Treat Noise-Induced Hearing Loss
2014-08-13
be reduced by 40 dB, resulting in a 115 dB SPL of noise exposure for personnel servicing the flight operations. (5) BODY: Scientific and Technical...80 . 70 . Zklh ! 60 i - 41oHz 81611 16KH.I i 50 ·-·-----~~---- ! 40 l i JO • 1 zo ------------ 10 0 Z IoHz 41oHz 81oHz 16KHz...15•0/0I ~ 40 \\-- •• -----~r-----/----- -n-151131!0/JOOJ ! JO : 1 zo ’------~~--------- 10 0 1 IoHz 41oHz 8IoHz 16KHz 2 Main Effect: • • • -+-(S.0
ERIC Educational Resources Information Center
Schlauch, Robert S.; Han, Heekyung J.; Yu, Tzu-Ling J.; Carney, Edward
2017-01-01
Purpose: The purpose of this article is to examine explanations for pure-tone average-spondee threshold differences in functional hearing loss. Method: Loudness magnitude estimation functions were obtained from 24 participants for pure tones (0.5 and 1.0 kHz), vowels, spondees, and speech-shaped noise as a function of level (20-90 dB SPL).…
Stuart, Andrew; Butler, Alyson K
2012-10-01
One purported role of the medial olivocochlear (MOC) efferent system is to reduce the effects of masking noise. MOC system functioning can be evaluated noninvasively in humans through contralateral suppression of otoacoustic emissions. It has been suggested that the strength of the MOC efferent activity should be positively associated with listening performance in noise. The objective of the study was to further explore this notion by examining contralateral suppression of transient evoked otoacoustic emissions (TEOAEs) and sentence recognition in two noises with normal hearing young adults. A repeated measures multivariate quasi-experimental design was employed. Thirty-two normal hearing young adult females participated. Reception thresholds for sentences (RTSs) were determined monaurally and binaurally in quiet and in competing continuous and interrupted noises. Both noises had an identical power spectrum and differed only in their temporal continuity. "Release from masking" was computed by subtracting RTS signal-to-noise ratios in interrupted from continuous noise. TEOAEs were evoked with 80 dB peSPL click stimuli. To examine contralateral suppression, TEOAEs were evaluated with 60 dB peSPL click stimuli with and without a contralateral 65 dB SPL white noise suppressor. A binaural advantage was observed for RTSs in quiet and noise (p < .0001) while there was no difference between ears (p >.05). In noise, performance was superior in the interrupted noise (i.e., RTSs were lower vs. continuous noise; p < .0001). There were no statistically significant differences in TEOAE levels between ears (p >.05). There was also no significant difference in the amount of suppression between ears (p = .41). There were no significant correlations or predictive linear relations between the amount of TEOAE suppression and any indices of sentence recognition in noise (i.e., RTS signal-to-noise ratios and release from masking; p > .05). The findings are not consistent with the notion that increased medial olivocochlear efferent feedback, as assessed via contralateral suppression of TEOAEs, is associated with improved speech perception in continuous and interrupted noise. American Academy of Audiology.
The Words-in-Noise Test (WIN), list 3: a practice list.
Wilson, Richard H; Watts, Kelly L
2012-02-01
The Words-in-Noise Test (WIN) was developed as an instrument to quantify the ability of listeners to understand monosyllabic words in background noise using multitalker babble (Wilson, 2003). The 50% point, which is calculated with the Spearman-Kärber equation (Finney, 1952), is used as the evaluative metric with the WIN materials. Initially, the WIN was designed as a 70-word instrument that presented ten unique words at each of seven signal-to-noise ratios from 24 to 0 dB in 4 dB decrements. Subsequently, the 70-word list was parsed into two 35-word lists that achieved equivalent recognition performances (Wilson and Burks, 2005). This report involves the development of a third list (WIN List 3) that was developed to serve as a practice list to familiarize the participant with listening to words presented in background babble. To determine-on young listeners with normal hearing and on older listeners with sensorineural hearing loss-the psychometric properties of the WIN List 3 materials. A quasi-experimental, repeated-measures design was used. Twenty-four young adult listeners (M = 21.6 yr) with normal pure-tone thresholds (≤ 20 dB HL at 250 to 8000 Hz) and 24 older listeners (M = 65.9 yr) with sensorineural hearing loss participated. The level of the babble was fixed at 80 dB SPL with the level of the words varied from 104 to 80 dB SPL in 4 dB decrements. For listeners with normal hearing, the 50% points for Lists 1 and 2 were similar (4.3 and 5.1 dB S/N, respectively), both of which were lower than the 50% point for List 3 (7.4 dB S/N). A similar relation was observed with the listeners with hearing loss, 50% points for Lists 1 and 2 of 12.2 and 12.4 dB S/N, respectively, compared to 15.8 dB S/N for List 3. The differences between Lists 1 and 2 and List 3 were significant. The relations among the psychometric functions and the relations among the individual data both reflected these differences. The significant ∼3 dB difference between performances on WIN Lists 1 and 2 and on WIN List 3 by the listeners with normal hearing and the listeners with hearing loss dictates caution with the use of List 3. The use of WIN List 3 should be reserved for ancillary purposes in which equivalent recognition performances are not required, for example, as a practice list or a stand alone measure. American Academy of Audiology.
Lobarinas, Edward; Scott, Ryan; Spankovich, Christopher; Le Prell, Colleen G
2016-01-01
Firearm discharges produce hazardous levels of impulse noise that can lead to permanent hearing loss. In the present study, we evaluated the effects of suppression, ammunition, and barrel length on AR-15 rifles. Sound levels were measured left/right of a user's head, and 1-m left of the muzzle, per MIL-STD-1474-D, under both unsuppressed and suppressed conditions. Nine commercially available AR-15 rifles and 14 suppressors were used. Suppressors significantly decreased peak dB SPL at the 1-m location and the left ear location. However, under most rifle/ammunition conditions, levels remained above 140 dB peak SPL near a user's right ear. In a subset of conditions, subsonic ammunition produced values near or below 140 dB peak SPL. Overall suppression ranged from 7-32 dB across conditions. These data indicate that (1) suppressors reduce discharge levels to 140 dB peak SPL or below in only a subset of AR-15 conditions, (2) shorter barrel length and use of muzzle brake devices can substantially increase exposure level for the user, and (3) there are significant left/right ear sound pressure differences under suppressed conditions as a function of the AR-15 direct impingement design that must be considered during sound measurements to fully evaluate overall efficacy.
Moore, Brian C J; Stone, Michael A; Füllgrabe, Christian; Glasberg, Brian R; Puria, Sunil
2008-12-01
It is possible for auditory prostheses to provide amplification for frequencies above 6 kHz. However, most current hearing-aid fitting procedures do not give recommended gains for such high frequencies. This study was intended to provide information that could be useful in quantifying appropriate high-frequency gains, and in establishing the population of hearing-impaired people who might benefit from such amplification. The study had two parts. In the first part, wide-bandwidth recordings of normal conversational speech were obtained from a sample of male and female talkers. The recordings were used to determine the mean spectral shape over a wide frequency range, and to determine the distribution of levels (the speech dynamic range) as a function of center frequency. In the second part, audiometric thresholds were measured for frequencies of 0.125, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, and 12.5 kHz for both ears of 31 people selected to have mild or moderate cochlear hearing loss. The hearing loss was never greater than 70 dB for any frequency up to 4 kHz. The mean spectrum level of the speech fell progressively with increasing center frequency above about 0.5 kHz. For speech with an overall level of 65 dB SPL, the mean 1/3-octave level was 49 and 37 dB SPL for center frequencies of 1 and 10 kHz, respectively. The dynamic range of the speech was similar for center frequencies of 1 and 10 kHz. The part of the dynamic range below the root-mean-square level was larger than reported in previous studies. The mean audiometric thresholds at high frequencies (10 and 12.5 kHz) were relatively high (69 and 77 dB HL, respectively), even though the mean thresholds for frequencies below 4 kHz were 41 dB HL or better. To partially restore audibility for a hearing loss of 65 dB at 10 kHz would require an effective insertion gain of about 36 dB at 10 kHz. With this gain, audibility could be (partly) restored for 25 of the 62 ears assessed.
The effect of aircraft speed on the penetration of sonic boom noise into a flat ocean
NASA Technical Reports Server (NTRS)
Sparrow, Victor W.
1994-01-01
As U.S. aircraft manufacturers now have focused their HSCT efforts on overwater supersonic flight, a great deal more must be known about sonic booms propagating overwater and interacting with the ocean. For example, it is thought that atmospheric turbulence effects are often much less severe over water than over land. Another important aspect of the overwater flight problems is the penetration of the sonic boom noise into the ocean, where there could be an environmental impact on sea life. This talk will present a brief review on the penetration of sonic boom noise into a large body of water with a flat surface. It has been determined recently that faster supersonic speeds imply greater penetration of sonic boom noise into the ocean. The new theory is derived from the original Sawyers paper and from the knowledge that for level flight a boom's duration is proportional to the quantity M/(M(exp 2)-1)(exp 3/8) where M is the Mach number. It is found that for depths of 10 m or less, the peak SPL varies less than 6 dB over a wide range of M. For greater depths, 100 m for example, increased Mach numbers may increase the SPL by 15 dB or more.
Impact of infrasound on the human cochlea.
Hensel, Johannes; Scholz, Günther; Hurttig, Ulrike; Mrowinski, Dieter; Janssen, Thomas
2007-11-01
Low-frequency tones were reported to modulate the amplitude of distortion product otoacoustic emissions (DPOAEs) indicating periodic changes of the operating point of the cochlear amplifier. The present study investigates potential differences between infrasound and low-frequency sounds in their ability to modulate human DPOAEs. DPOAEs were recorded in 12 normally hearing subjects in the presence of a biasing tone with f(B)=6Hz and a level L(B)=130dB SPL. Primary frequencies were fixed at f(1)=1.6 and f(2)=2.0kHz with fixed levels L(1)=51 and L(2)=30dB SPL. A new measure, the modulation index (MI), was devised to characterise the degree of DPOAE modulation. In subsequent measurements with biasing tones of f(B) = 12, 24 and 50Hz, L(B) was adjusted to maintain the MI as obtained individually at 6Hz. Modulation patterns lagged with increasing f(B). The necessary L(B) decreased by 12dB/octave with increasing f(B) and ran almost parallel to the published infrasound detection threshold. No signs of an abrupt change in transmission into the cochlea were found between infra- and low-frequency sounds. The results show clearly that infrasound enters the inner ear, and can alter cochlear processing.
Young adults' use and output level settings of personal music systems.
Torre, Peter
2008-10-01
There are growing concerns over noise exposure via personal music system use by young adults. One purpose of this study was to evaluate the prevalence of personal music system use and the listening patterns associated with these systems in a large sample of young adults. A second purpose of this study was to measure the dB SPL in the ear canal of young adults while they blindly set the volume of a personal music system to four settings. In the first study, the personal music system use survey was completed by 1016 students at various locations on the San Diego State University campus. Questions included sex, age, ethnicity, race, and whether or not they used a personal music system. Students who answered Yes to using a personal music system were instructed to complete the remaining 11 closed-set questions. These questions dealt with type of earphones used with the system, most common listening environment, length of time per day the system was used, and the volume setting. The differences between women and men and across ethnicity and race were evaluated for the questions. In the second study, a probe microphone placed in the ear canal of 32 participants was used to determine the dB SPL of four loudness categories at which the participants blindly set the level of a personal music system: low, medium or comfortable, loud, and very loud. In study 1, over 90% of the participants who completed the survey reported using a personal music system. Over 50% of those who use a personal music system reported listening between 1 and 3 hrs and almost 90% reported listening at either a medium or loud volume. Men were significantly more likely to report listening to their system for a longer duration compared with women and more likely to report listening at a very loud volume. There was a trend for Hispanic or Latino students to report listening for longer durations compared with Not Hispanic or Latino students, but this difference was not statistically significant. Black or African American students were significantly more likely to report listening to their personal music system between 3 and 5 hrs and more than 5 hrs and to report listening at a very loud volume compared with other racial groups. In study 2, the mean dB SPL values for low, medium or comfortable, loud, and very loud were 62.0, 71.6, 87.7, and 97.8 dB SPL, respectively. Men set the level of very loud significantly higher than women. It is clear that a vast majority of young adults who completed the personal music system use survey listen to a system using earphones. Most of the respondents listen between 1 and 3 hrs a day at a medium or loud volume. Based on the probe microphone measurement results, the volume settings for reported durations may not be hazardous for hearing. Long-term use of personal music systems, however, in combination with other noise exposures (i.e., recreational, occupational), and their effect on hearing remains a question for additional research.
NASA Astrophysics Data System (ADS)
Dalhoff, Ernst; Zelle, Dennis; Gummer, Anthony W.
2015-12-01
Measurement of contralateral suppression or ipsilateral adaptation of DPOAE due to the medial olivocochlear reflex (MOCR) in humans has so far been complicated by interference between the two major contributors to a DPOAE signal, namely, the nonlinear and the reflection-source components. For instance, while the MOCR has been shown to act inhibitory to the cochlear amplifier, a considerable share of the measured responses has been reported to be of the excitatory type (e.g. 22% for contralateral adaptation in [11]), and it has been shown that the magnitudes of ipsilateral adaptation as well as contralateral suppression depend on the precise frequency choice relative to the position of dips in the DPOAE fine structure [3, 8]. To separate MOCR effects on both source components, we developed a paradigm consisting of five short f2 pulses presented during a 0.35 s on-period of the f1 primary within blocks of 1.35 s length. The responses at f1 and f2 were cancelled using the primary-tone phase variation technique [13]. In 16 normal-hearing subjects, we measured MOCR-induced ipsilateral adaptation at three near-by frequencies in the DPOAE fine structure, corresponding roughly to characteristic interference states between the two major source components of a DPOAE, i.e. constructive, destructive and quadrature interference. Measurements were performed in the frequency range 1.7 ≤ f2 ≤ 2 kHz, f2/f1 = 1.2, and with moderate primary-tone levels (L2 = 45 dB SPL, L1 = 57 dB SPL). Analysis of the DPOAE time traces showed that the nonlinear component typically presents inhibitory adaptation between the 1st and the 5th pulses (median: 0.92 dB). Fitting a single exponential function to the pooled data yielded adaptation of 1.49 dB. From 26 statistically significant MOCR effects (P < 0.1) ranging between 0.29 and 2.81 dB, no excitatory response was detected. The separation of the DPOAE sources when analysing MOCR effects on ipsilateral DPOAE offers the potential of investigating the human efferent system more specifically than hitherto possible.
Sperm whales reduce foraging effort during exposure to 1-2 kHz sonar and killer whale sounds.
Isojunno, Saana; Cure, Charlotte; Kvadsheim, Petter Helgevold; Lam, Frans-Peter Alexander; Tyack, Peter Lloyd; Wensveen, Paul Jacobus; Miller, Patrick James O'Malley
2016-01-01
The time and energetic costs of behavioral responses to incidental and experimental sonar exposures, as well as control stimuli, were quantified using hidden state analysis of time series of acoustic and movement data recorded by tags (DTAG) attached to 12 sperm whales (Physeter macrocephalus) using suction cups. Behavioral state transition modeling showed that tagged whales switched to a non-foraging, non-resting state during both experimental transmissions of low-frequency active sonar from an approaching vessel (LFAS; 1-2 kHz, source level 214 dB re 1 µPa m, four tag records) and playbacks of potential predator (killer whale, Orcinus orca) sounds broadcast at naturally occurring sound levels as a positive control from a drifting boat (five tag records). Time spent in foraging states and the probability of prey capture attempts were reduced during these two types of exposures with little change in overall locomotion activity, suggesting an effect on energy intake with no immediate compensation. Whales switched to the active non-foraging state over received sound pressure levels of 131-165 dB re 1 µPa during LFAS exposure. In contrast, no changes in foraging behavior were detected in response to experimental negative controls (no-sonar ship approach or noise control playback) or to experimental medium-frequency active sonar exposures (MFAS; 6-7 kHz, source level 199 re 1 µPa m, received sound pressure level [SPL] = 73-158 dB re 1 µPa). Similarly, there was no reduction in foraging effort for three whales exposed to incidental, unidentified 4.7-5.1 kHz sonar signals received at lower levels (SPL = 89-133 dB re 1 µPa). These results demonstrate that similar to predation risk, exposure to sonar can affect functional behaviors, and indicate that increased perception of risk with higher source level or lower frequency may modulate how sperm whales respond to anthropogenic sound.
Martin, B A; Sigal, A; Kurtzberg, D; Stapells, D R
1997-03-01
This study investigated the effects of decreased audibility produced by high-pass noise masking on cortical event-related potentials (ERPs) N1, N2, and P3 to the speech sounds /ba/and/da/presented at 65 and 80 dB SPL. Normal-hearing subjects pressed a button in response to the deviant sound in an oddball paradigm. Broadband masking noise was presented at an intensity sufficient to completely mask the response to the 65-dB SPL speech sounds, and subsequently high-pass filtered at 4000, 2000, 1000, 500, and 250 Hz. With high-pass masking noise, pure-tone behavioral thresholds increased by an average of 38 dB at the high-pass cutoff and by 50 dB one octave above the cutoff frequency. Results show that as the cutoff frequency of the high-pass masker was lowered, ERP latencies to speech sounds increased and amplitudes decreased. The cutoff frequency where these changes first occurred and the rate of the change differed for N1 compared to N2, P3, and the behavioral measures. N1 showed gradual changes as the masker cutoff frequency was lowered. N2, P3, and behavioral measures showed marked changes below a masker cutoff of 2000 Hz. These results indicate that the decreased audibility resulting from the noise masking affects the various ERP components in a differential manner. N1 is related to the presence of audible stimulus energy, being present whether audible stimuli are discriminable or not. In contrast, N2 and P3 were absent when the stimuli were audible but not discriminable (i.e., when the second formant transitions were masked), reflecting stimulus discrimination. These data have implications regarding the effects of decreased audibility on cortical processing of speech sounds and for the study of cortical ERPs in populations with hearing impairment.
The effect of presentation level on memory performance.
Heinrich, Antje; Schneider, Bruce A
2011-01-01
A loss of speech intelligibility at high presentation levels is called rollover. It is a phenomenon that increases in prevalence as people age. Whether the adverse effect of high presentation levels extends to processes subsequent to speech intelligibility, such as memory, is unknown. The present study examined this question on the basis of the previous finding that older but not younger adults showed memory impairment when acoustically distorted words were presented at 50 dB SL compared with an undistorted baseline presented at 65 dB SPL. One question investigated in the present study was whether a presentation level of 50 dB SL put older listeners at the cusp of rollover and whether this subsequently impaired memory. Moreover, we wanted to know whether and at what level it was possible to induce a similar impairment in younger listeners. We used a paired-associate memory paradigm in which five word pairs per list were presented at a rate of 4 secs per word pair. After each list, the first word of one of the pairs was presented again and the listener was asked to recall the second word. Over the course of the experiment, all list positions were tested an equal number of times. The word pairs, which were acoustically distorted using a jittering algorithm, were presented at 40 dB SL to all younger and older participants and just below an uncomfortably loud level for younger listeners only. Intelligibility of the distorted words was equated across age groups for each presentation level. The effect of presentation level on memory performance was investigated and compared with data of a previous study that used the same design but presented the distorted and undistorted words at 50 dB SL to both age groups. A total of 58 younger and 24 older adults were tested in two experiments. The results showed that for older adults, memory performance for distorted words was decreased in all list positions at a presentation level of 50 dB SL compared with 40 dB SL and an undistorted 65 dB SPL baseline. This effect did not occur for younger listeners. However, when younger adults were tested at a very high presentation level, they showed the same memory decrease compared with the baseline as older adults showed for 50 dB SL. A high presentation level of distorted words can adversely affect memory even after intelligibility is equated for. Moreover, older listeners are affected at lower presentation levels. Hence, the choice of sound level, particularly for older listeners, is important and may affect their level of cognitive performance beyond its effects on intelligibility. Higher presentation levels may not always lead to better performance when the task involves recall of words previously heard.
Zeh, R; Baumann, U
2015-08-01
Cochlear implants (CI) have proven to be a highly effective treatment for severe hearing loss or deafness. Inpatient rehabilitation therapy is frequently discussed as a means to increase the speech perception abilities achieved by CI. However, thus far there exists no quantitative evaluation of the effect of these therapies. A retrospective analysis of audiometric data obtained from 1355 CI users compared standardized and qualitative speech intelligibility tests conducted at two time points (admission to and discharge from inpatient hearing therapy, duration 3-5 weeks). The test battery comprised examination of vowel/consonant identification, the Freiburg numbers and monosyllabic test (65 and 80 dB sound pressure level, SPL, free-field sound level), the Hochmair-Schulz-Moser (HSM) sentence test in quiet and in noise (65 dB SPL speech level; 15 dB signal-to-noise ratio, SNR), and a speech tracking test with and without lip-reading. An average increase of 20 percentage points was scored at discharge compared to the admission tests. Patients of all ages and duration of deafness demonstrated the same amount of benefit from the rehabilitation treatment. After completion of inpatient rehabilitation treatment, patients with short duration of CI experience (below 4 months) achieved test scores comparable to experienced long-term users. The demonstrated benefit of the treatment was independent of age and duration of deafness or CI experience. The rehabilitative training program significantly improved hearing abilities and speech perception in CI users, thus promoting their professional and social inclusion. The present results support the efficacy of inpatient rehabilitation for CI recipients. Integration of this or similar therapeutic concepts in the German catalog of follow-up treatment measures appears justified.
Acoustic noise during functional magnetic resonance imaginga)
Ravicz, Michael E.; Melcher, Jennifer R.; Kiang, Nelson Y.-S.
2007-01-01
Functional magnetic resonance imaging (fMRI) enables sites of brain activation to be localized in human subjects. For studies of the auditory system, acoustic noise generated during fMRI can interfere with assessments of this activation by introducing uncontrolled extraneous sounds. As a first step toward reducing the noise during fMRI, this paper describes the temporal and spectral characteristics of the noise present under typical fMRI study conditions for two imagers with different static magnetic field strengths. Peak noise levels were 123 and 138 dB re 20 μPa in a 1.5-tesla (T) and a 3-T imager, respectively. The noise spectrum (calculated over a 10-ms window coinciding with the highest-amplitude noise) showed a prominent maximum at 1 kHz for the 1.5-T imager (115 dB SPL) and at 1.4 kHz for the 3-T imager (131 dB SPL). The frequency content and timing of the most intense noise components indicated that the noise was primarily attributable to the readout gradients in the imaging pulse sequence. The noise persisted above background levels for 300-500 ms after gradient activity ceased, indicating that resonating structures in the imager or noise reverberating in the imager room were also factors. The gradient noise waveform was highly repeatable. In addition, the coolant pump for the imager’s permanent magnet and the room air handling system were sources of ongoing noise lower in both level and frequency than gradient coil noise. Knowledge of the sources and characteristics of the noise enabled the examination of general approaches to noise control that could be applied to reduce the unwanted noise during fMRI sessions. PMID:11051496
NASA Astrophysics Data System (ADS)
Konrad-Martin, Dawn; Neely, Stephen T.; Keefe, Douglas H.; Dorn, Patricia A.; Cyr, Emily; Gorga, Michael P.
2002-04-01
DPOAE sources are modeled by intermodulation distortion generated near the f2 place and a reflection of this distortion near the DP place. In a previous paper, inverse fast Fourier transforms (IFFTs) of DPOAE filter functions in normal ears were consistent with this model [Konrad-Martin et al., J. Acoust. Soc. Am. 109, 2862-2879 (2001)]. In the present article, similar measurements were made in ears with specific hearing-loss configurations. It was hypothesized that hearing loss at f2 or DP frequencies would influence the relative contributions to the DPOAE from the corresponding basilar membrane places, and would affect the relative magnitudes of SFOAEs at frequencies equal to f2 and fDP. DPOAEs were measured with f2=4 kHz, f1 varied, and a suppressor near fDP. L2 was 25-55 dB SPL (L1=L2+10 dB). SFOAEs were measured at f2 and at 2.7 kHz (the average fDP produced by the f1 sweep) for stimulus levels of 20-60 dB SPL. SFOAE results supported predictions of the pattern of amplitude differences between SFOAEs at 4 and 2.7 kHz for sloping losses, but did not support predictions for the rising- and flat-loss categories. Unsuppressed IFFTs for rising losses typically had one peak. IFFTs for flat or sloping losses typically have two or more peaks; later peaks were more prominent in ears with sloping losses compared to normal ears. Specific predictions were unambiguously supported by the results for only four of ten cases, and were generally supported in two additional cases. Therefore, the relative contributions of the two DPOAE sources often were abnormal in impaired ears, but not always in the predicted manner.
Development of the Russian matrix sentence test.
Warzybok, Anna; Zokoll, Melanie; Wardenga, Nina; Ozimek, Edward; Boboshko, Maria; Kollmeier, Birger
2015-01-01
To develop the Russian matrix sentence test for speech intelligibility measurements in noise. Test development included recordings, optimization of speech material, and evaluation to investigate the equivalency of the test lists and training. For each of the 500 test items, the speech intelligibility function, speech reception threshold (SRT: signal-to-noise ratio, SNR, that provides 50% speech intelligibility), and slope was obtained. The speech material was homogenized by applying level corrections. In evaluation measurements, speech intelligibility was measured at two fixed SNRs to compare list-specific intelligibility functions. To investigate the training effect and establish reference data, speech intelligibility was measured adaptively. Overall, 77 normal-hearing native Russian listeners. The optimization procedure decreased the spread in SRTs across words from 2.8 to 0.6 dB. Evaluation measurements confirmed that the 16 test lists were equivalent, with a mean SRT of -9.5 ± 0.2 dB and a slope of 13.8 ± 1.6%/dB. The reference SRT, -8.8 ± 0.8 dB for the open-set and -9.4 ± 0.8 dB for the closed-set format, increased slightly for noise levels above 75 dB SPL. The Russian matrix sentence test is suitable for accurate and reliable speech intelligibility measurements in noise.
Bauer, Jay J; Mittal, Jay; Larson, Charles R; Hain, Timothy C
2006-04-01
The present study tested whether subjects respond to unanticipated short perturbations in voice loudness feedback with compensatory responses in voice amplitude. The role of stimulus magnitude (+/- 1,3 vs 6 dB SPL), stimulus direction (up vs down), and the ongoing voice amplitude level (normal vs soft) were compared across compensations. Subjects responded to perturbations in voice loudness feedback with a compensatory change in voice amplitude 76% of the time. Mean latency of amplitude compensation was 157 ms. Mean response magnitudes were smallest for 1-dB stimulus perturbations (0.75 dB) and greatest for 6-dB conditions (0.98 dB). However, expressed as gain, responses for 1-dB perturbations were largest and almost approached 1.0. Response magnitudes were larger for the soft voice amplitude condition compared to the normal voice amplitude condition. A mathematical model of the audio-vocal system captured the main features of the compensations. Previous research has demonstrated that subjects can respond to an unanticipated perturbation in voice pitch feedback with an automatic compensatory response in voice fundamental frequency. Data from the present study suggest that voice loudness feedback can be used in a similar manner to monitor and stabilize voice amplitude around a desired loudness level.
Measor, Kevin R; Leavell, Brian C; Brewton, Dustin H; Rumschlag, Jeffrey; Barber, Jesse R; Razak, Khaleel A
2017-01-01
In active sensing, animals make motor adjustments to match sensory inputs to specialized neural circuitry. Here, we describe an active sensing system for sound level processing. The pallid bat uses downward frequency-modulated (FM) sweeps as echolocation calls for general orientation and obstacle avoidance. The bat's auditory cortex contains a region selective for these FM sweeps (FM sweep-selective region, FMSR). We show that the vast majority of FMSR neurons are sensitive and strongly selective for relatively low levels (30-60 dB SPL). Behavioral testing shows that when a flying bat approaches a target, it reduces output call levels to keep echo levels between ∼30 and 55 dB SPL. Thus, the pallid bat behaviorally matches echo levels to an optimized neural representation of sound levels. FMSR neurons are more selective for sound levels of FM sweeps than tones, suggesting that across-frequency integration enhances level tuning. Level-dependent timing of high-frequency sideband inhibition in the receptive field shapes increased level selectivity for FM sweeps. Together with previous studies, these data indicate that the same receptive field properties shape multiple filters (sweep direction, rate, and level) for FM sweeps, a sound common in multiple vocalizations, including human speech. The matched behavioral and neural adaptations for low-intensity echolocation in the pallid bat will facilitate foraging with reduced probability of acoustic detection by prey.
Punch, Simone; Van Dun, Bram; King, Alison; Carter, Lyndal; Pearce, Wendy
2016-01-01
This article presents the clinical protocol that is currently being used within Australian Hearing for infant hearing aid evaluation using cortical auditory evoked potentials (CAEPs). CAEP testing is performed in the free field at two stimulus levels (65 dB sound pressure level [SPL], followed by 55 or 75 dB SPL) using three brief frequency-distinct speech sounds /m/, /ɡ/, and /t/, within a standard audiological appointment of up to 90 minutes. CAEP results are used to check or guide modifications of hearing aid fittings or to confirm unaided hearing capability. A retrospective review of 83 client files evaluated whether clinical practice aligned with the clinical protocol. It showed that most children could be assessed as part of their initial fitting program when they were identified as a priority for CAEP testing. Aided CAEPs were most commonly assessed within 8 weeks of the fitting. A survey of 32 pediatric audiologists provided information about their perception of cortical testing at Australian Hearing. The results indicated that clinical CAEP testing influenced audiologists' approach to rehabilitation and was well received by parents and that they were satisfied with the technique. Three case studies were selected to illustrate how CAEP testing can be used in a clinical environment. Overall, CAEP testing has been effectively integrated into the infant fitting program. PMID:27587921
Measor, Kevin R.; Leavell, Brian C.; Brewton, Dustin H.; Rumschlag, Jeffrey; Barber, Jesse R.
2017-01-01
Abstract In active sensing, animals make motor adjustments to match sensory inputs to specialized neural circuitry. Here, we describe an active sensing system for sound level processing. The pallid bat uses downward frequency-modulated (FM) sweeps as echolocation calls for general orientation and obstacle avoidance. The bat’s auditory cortex contains a region selective for these FM sweeps (FM sweep-selective region, FMSR). We show that the vast majority of FMSR neurons are sensitive and strongly selective for relatively low levels (30-60 dB SPL). Behavioral testing shows that when a flying bat approaches a target, it reduces output call levels to keep echo levels between ∼30 and 55 dB SPL. Thus, the pallid bat behaviorally matches echo levels to an optimized neural representation of sound levels. FMSR neurons are more selective for sound levels of FM sweeps than tones, suggesting that across-frequency integration enhances level tuning. Level-dependent timing of high-frequency sideband inhibition in the receptive field shapes increased level selectivity for FM sweeps. Together with previous studies, these data indicate that the same receptive field properties shape multiple filters (sweep direction, rate, and level) for FM sweeps, a sound common in multiple vocalizations, including human speech. The matched behavioral and neural adaptations for low-intensity echolocation in the pallid bat will facilitate foraging with reduced probability of acoustic detection by prey. PMID:28275715
Safety and clinical performance of acoustic reflex tests.
Hunter, L L; Ries, D T; Schlauch, R S; Levine, S C; Ward, W D
1999-12-01
Safety and effectiveness of acoustic reflex tests are important issues because these tests are widely applied to screen for retrocochlear pathology. Previous studies have reported moderately high sensitivity and specificity for detection of acoustic neuroma. However, there have been reports of possible iatrogenic hearing loss resulting from acoustic reflex threshold (ART) and decay (ARD) tests. This study assessed safety and clinical performance of ART tests for detection of acoustic neuroma. We report a case in which ARD testing resulted in a significant bilateral permanent threshold shift. This case was the impetus for us to investigate the clinical utility of ART and ARD tests. We analyzed sensitivity and specificity of ART, as well as asymmetry in pure-tone thresholds (PTT) for detection of acoustic neuroma in 56 tumor and 108 non-tumor ears. Sensitivity and specificity were higher for PTT asymmetry than for ART. Ipsilateral ART at 1000 Hz had poor sensitivity and specificity for detection of acoustic neuroma, and involves some potential risk to residual hearing for presentation levels higher than 115 dB SPL. Approximately half of the acoustic neuroma group had ipsilateral ARTs that would require administration of ARD tests at levels exceeding 115 dB SPL. Therefore, we conclude that PTT asymmetry is a more effective test for detection of acoustic neuroma, and involves no risk to residual hearing. Future studies of contralateral reflex threshold and ARD in combination with PTT asymmetry are recommended.
McQuinn, Ian H; Lesage, Véronique; Carrier, Dominic; Larrivée, Geneviève; Samson, Yves; Chartrand, Sylvain; Michaud, Robert; Theriault, James
2011-12-01
The threatened resident beluga population of the St. Lawrence Estuary shares the Saguenay-St. Lawrence Marine Park with significant anthropogenic noise sources, including marine commercial traffic and a well-established, vessel-based whale-watching industry. Frequency-dependent (FD) weighting was used to approximate beluga hearing sensitivity to determine how noise exposure varied in time and space at six sites of high beluga summer residency. The relative contribution of each source to acoustic habitat degradation was estimated by measuring noise levels throughout the summer and noise signatures of typical vessel classes with respect to traffic volume and sound propagation characteristics. Rigid-hulled inflatable boats were the dominant noise source with respect to estimated beluga hearing sensitivity in the studied habitats due to their high occurrence and proximity, high correlation with site-specific FD-weighted sound levels, and the dominance of mid-frequencies (0.3-23 kHz) in their noise signatures. Median C-weighted sound pressure level (SPL(RMS)) had a range of 19 dB re 1 μPa between the noisiest and quietest sites. Broadband SPL(RMS) exceeded 120 dB re 1 μPa 8-32% of the time depending on the site. Impacts of these noise levels on St. Lawrence beluga will depend on exposure recurrence and individual responsiveness. © 2011 Acoustical Society of America
Crespo-Maraver, Mariacruz; Doval, Eduardo; Fernández-Castro, Jordi; Giménez-Salinas, Jordi; Prat, Gemma; Bonet, Pere
2018-04-04
To adapt and to validate the Experience of Caregiving Inventory (ECI) in a Spanish population, providing empirical evidence of its internal consistency, internal structure and validity. Psychometric validation of the adapted version of the ECI. One hundred and seventy-two caregivers (69.2% women), mean age 57.51 years (range: 21-89) participated. Demographic and clinical data, standardized measures (ECI, suffering scale of SCL-90-R, Zarit burden scale) were used. The two scales of negative evaluation of the ECI most related to serious mental disorders (disruptive behaviours [DB] and negative symptoms [NS]) and the two scales of positive appreciation (positive personal experiences [PPE], and good aspects of the relationship [GAR]) were analyzed. Exploratory structural equation modelling was used to analyze the internal structure. The relationship between the ECI scales and the SCL-90-R and Zarit scores was also studied. The four-factor model presented a good fit. Cronbach's alpha (DB: 0.873; NS: 0.825; PPE: 0.720; GAR: 0.578) showed a higher homogeneity in the negative scales. The SCL-90-R scores correlated with the negative ECI scales, and none of the ECI scales correlated with the Zarit scale. The Spanish version of the ECI can be considered a valid, reliable, understandable and feasible self-report measure for its administration in the health and community context. Copyright © 2018 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
Lee, Kyoung-Ryul; Jang, Sung Hwan; Jung, Inhwa
2018-08-10
We investigated the acoustic performance of electrostatic sound-generating devices consisting of bi-layer graphene on polyimide film. The total sound pressure level (SPL) of the sound generated from the devices was measured as a function of source frequency by sweeping, and frequency spectra were measured at 1/3 octave band frequencies. The relationship between various operation conditions and total SPL was determined. In addition, the effects of changing voltage level, adding a DC offset, and using two pairs of electrodes were evaluated. It should be noted that two pairs of electrode operations improved sound generation by about 10 dB over all frequency ranges compared with conventional operation. As for the sound-generating capability, total SPL was 70 dBA at 4 kHz when an AC voltage of 100 V pp was applied with a DC offset of 100 V. Acoustic characteristics differed from other types of graphene-based sound generators, such as graphene thermoacoustic devices and graphene polyvinylidene fluoride devices. The effects of diameter and distance between electrodes were also studied, and we found that diameter greatly influenced the frequency response. We anticipate that the design information provided in this paper, in addition to describing key parameters of electrostatic sound-generating devices, will facilitate the commercial development of electrostatic sound-generating systems.
Connaughton, M A; Taylor, M H; Fine, M L
2000-05-01
To categorize variation in disturbance calls of the weakfish Cynoscion regalis and to understand their generation, we recorded sounds produced by different-sized fish, and by similar-sized fish at different temperatures, as well as muscle electromyograms. Single, simultaneous twitches of the bilateral sonic muscles produce a single sound pulse consisting of a two- to three-cycle acoustic waveform. Typical disturbance calls at 18 degrees C consist of trains of 2-15 pulses with a sound pressure level (SPL) of 74 dB re 20 microPa at 10 cm, a peak frequency of 540 Hz, a repetition rate of 20 Hz and a pulse duration of 3.5 ms. The pulse duration suggests an incredibly short twitch time. Sound pressure level (SPL) and pulse duration increase and dominant frequency decreases in larger fish, whereas SPL, repetition rate and dominant frequency increase and pulse duration decreases with increasing temperature. The dominant frequency is inversely related to pulse duration and appears to be determined by the duration of muscle contraction. We suggest that the lower dominant frequency of larger fish is caused by a longer pulse (=longer muscle twitch) and not by the lower resonant frequency of a larger swimbladder.
Van Hoesel, Richard; Ramsden, Richard; Odriscoll, Martin
2002-04-01
To characterize some of the benefits available from using two cochlear implants compared with just one, sound-direction identification (ID) abilities, sensitivity to interaural time delays (ITDs) and speech intelligibility in noise were measured for a bilateral multi-channel cochlear implant user. Sound-direction ID in the horizontal plane was tested with a bilateral cochlear implant user. The subject was tested both unilaterally and bilaterally using two independent behind-the-ear ESPRIT (Cochlear Ltd.) processors, as well as bilaterally using custom research processors. Pink noise bursts were presented using an 11-loudspeaker array spanning the subject's frontal 180 degrees arc in an anechoic room. After each burst, the subject was asked to identify which loudspeaker had produced the sound. No explicit training, and no feedback were given. Presentation levels were nominally at 70 dB SPL, except for a repeat experiment using the clinical devices where the presentation levels were reduced to 60 dB SPL to avoid activation of the devices' automatic gain control (AGC) circuits. Overall presentation levels were randomly varied by +/- 3 dB. For the research processor, a "low-update-rate" and a "high-update-rate" strategy were tested. Direct measurements of ITD just noticeable differences (JNDs) were made using a 3 AFC paradigm targeting 70% correct performance on the psychometric function. Stimuli included simple, low-rate electrical pulse trains as well as high-rate pulse trains modulated at 100 Hz. Speech data comparing monaural and binaural performance in noise were also collected with both low, and high update-rate strategies on the research processors. Open-set sentences were presented from directly in front of the subject and competing multi-talker babble noise was presented from the same loudspeaker, or from a loudspeaker placed 90 degrees to the left or right of the subject. For the sound-direction ID task, monaural performance using the clinical devices showed large mean absolute errors of 81 degrees and 73 degrees, with standard deviations (averaged across all 11 loud-speakers) of 10 degrees and 17 degrees, for left and right ears, respectively. Fore bilateral device use at a presentation level of 70 dB SPL, the mean error improved to about 16 degrees with an average standard deviation of 18 degrees. When the presentation level was decreased to 60 dB SPL to avoid activation of the automatic gain control (AGC) circuits in the clinical processors, the mean response error improved further to 8 degrees with a standard deviation of 13 degrees. Further tests with the custom research processors, which had a higher stimulation rate and did not include AGCs, showed comparable response errors: around 8 or 9 degrees and a standard deviation of about 11 degrees for both update rates. The best ITD JNDs measured for this subject were between 350 to 400 microsec for simple low-rate pulse trains. Speech results showed a substantial headshadow advantage for bilateral device use when speech and noise were spatially separated, but little evidence of binaural unmasking. For spatially coincident speech and noise, listening with both ears showed similar results to listening with either side alone when loudness summation was compensated for. No significant differences were observed between binaural results for high and low update-rates in any test configuration. Only for monaural listening in one test configuration did the high rate show a small significant improvement over the low rate. Results show that even if interaural time delay cues are not well coded or perceived, bilateral implants can offer important advantages, both for speech in noise as well as for sound-direction identification.
Comparison of hearing and voicing ranges in singing
NASA Astrophysics Data System (ADS)
Hunter, Eric J.; Titze, Ingo R.
2003-04-01
The spectral and dynamic ranges of the human voice of professional and nonprofessional vocalists were compared to the auditory hearing and feeling thresholds at a distance of one meter. In order to compare these, an analysis was done in true dB SPL, not just relative dB as is usually done in speech analysis. The methodology of converting the recorded acoustic signal to absolute pressure units was described. The human voice range of a professional vocalist appeared to match the dynamic range of the auditory system at some frequencies. In particular, it was demonstrated that professional vocalists were able to make use of the most sensitive part of the hearing thresholds (around 4 kHz) through the use of a learned vocal ring or singer's formant. [Work sponsored by NIDCD.
2015-09-01
reduction of SPL in dB as sound travels from a source to a receiver ( Urick 1983). The basic equation to obtain TL from measurements in a tonal transmission...attributed to the sum of losses due to spreading, multipath effects, scattering, and attenuation ( Urick 1983). Typical values for TL in different areas...executive.com/article/us-toughens- south-china-sea-stance.] Urick , R. J., 1983: Principles of Underwater Sound. 3rd ed. Peninsula Publishing, 423 pp. 32
Interaction of salicylate and noise results in mortality of rats.
Brennan, J F; Jastreboff, P J
1989-08-15
Survival as a function of salicylate dose and the intensity of environmental noise was investigated in 150 adult female pigmented rats. Rats were assigned to groups (n = 6/group) defined by combinations of salicylate levels from 0-(saline) to 300 mg/kg, injected subcutaneously, and noise levels from ambient noise to 98 dB SPL, presented daily for 10-h periods for up to 17 days. Mortality occurred in groups exposed to the higher combinations of salicylate and noise.
Kastelein, Ronald A; van Heerden, Dorianne; Gransier, Robin; Hoek, Lean
2013-12-01
The high under-water sound pressure levels (SPLs) produced during pile driving to build offshore wind turbines may affect harbor porpoises. To estimate the discomfort threshold of pile driving sounds, a porpoise in a quiet pool was exposed to playbacks (46 strikes/min) at five SPLs (6 dB steps: 130-154 dB re 1 μPa). The spectrum of the impulsive sound resembled the spectrum of pile driving sound at tens of kilometers from the pile driving location in shallow water such as that found in the North Sea. The animal's behavior during test and baseline periods was compared. At and above a received broadband SPL of 136 dB re 1 μPa [zero-peak sound pressure level: 151 dB re 1 μPa; t90: 126 ms; sound exposure level of a single strike (SELss): 127 dB re 1 μPa(2) s] the porpoise's respiration rate increased in response to the pile driving sounds. At higher levels, he also jumped out of the water more often. Wild porpoises are expected to move tens of kilometers away from offshore pile driving locations; response distances will vary with context, the sounds' source level, parameters influencing sound propagation, and background noise levels. Copyright © 2013 Elsevier Ltd. All rights reserved.
Dündar, Rıza; Soy, Fatih Kemal; Kulduk, Erkan; Muluk, Nuray Bayar; Cingi, Cemal
2014-10-01
The aim of this study was to introduce a new grafting technique in tympanoplasty that involves use of a boomerang-shaped chondroperichondrial graft (BSCPG). The anatomical and functional results were evaluated. A new tympanoplasty with boomerang-shaped chondroperichondrial graft (TwBSCPG) technique was used in 99 chronic otitis media patients with central or marginal perforation of the tympanic membrane and a normal middle ear mucosa. All 99 patients received chondroperichondrial cartilage grafts with a boomerang-shaped cartilage island left at the anterior and inferior parts. Postoperative follow-ups were conducted at months 1, 6, and 12. Preoperative and postoperative audiological examinations were performed and air-bone gaps were calculated according to the pure-tone averages (PTAs) of the patients. In the preoperative period, most (83.8%) air-bone gaps were ≥ 16 dB; after operating using the TwBSCPG technique, the air-bone gaps decreased to 0-10 dB in most patients (77.8%). In the TwBSCPG patients, the mean preoperative air-bone gap was 22.02 ± 6.74 dB SPL. Postoperatively, the mean postoperative air-bone gap was 8.70 ± 5.74 dB SPL. The TwBSCPG technique therefore decreased the postoperative air-bone gap compared to that preoperatively (p = 0.000, z = -8.645). At the 1-month follow-up, there were six graft perforations and one graft retraction. At the 6-month follow-up, there were nine graft perforations and three graft retractions. At 12 months, there were seven graft perforations and four graft retractions. During the first year after the boomerang tympanoplasty surgery, graft lateralization was not detected in any patient. Retractions were grade 1 according to the Sade classification and were localized to the postero-superior quadrant of the tympanic membrane. The TwBSCPG technique has benefits with respect to postoperative anatomical and audiological results. It prevents perforation of the tympanic membrane at the anterior quadrant and avoids graft lateralization due to placement of the graft under the manubrium mallei. Given these benefits, the TwBSCPG technique seems to be a good alternative for grafting in tympanoplasties.
Effect of Human Auditory Efferent Feedback on Cochlear Gain and Compression
Drga, Vit; Plack, Christopher J.
2014-01-01
The mammalian auditory system includes a brainstem-mediated efferent pathway from the superior olivary complex by way of the medial olivocochlear system, which reduces the cochlear response to sound (Warr and Guinan, 1979; Liberman et al., 1996). The human medial olivocochlear response has an onset delay of between 25 and 40 ms and rise and decay constants in the region of 280 and 160 ms, respectively (Backus and Guinan, 2006). Physiological studies with nonhuman mammals indicate that onset and decay characteristics of efferent activation are dependent on the temporal and level characteristics of the auditory stimulus (Bacon and Smith, 1991; Guinan and Stankovic, 1996). This study uses a novel psychoacoustical masking technique using a precursor sound to obtain a measure of the efferent effect in humans. This technique avoids confounds currently associated with other psychoacoustical measures. Both temporal and level dependency of the efferent effect was measured, providing a comprehensive measure of the effect of human auditory efferents on cochlear gain and compression. Results indicate that a precursor (>20 dB SPL) induced efferent activation, resulting in a decrease in both maximum gain and maximum compression, with linearization of the compressive function for input sound levels between 50 and 70 dB SPL. Estimated gain decreased as precursor level increased, and increased as the silent interval between the precursor and combined masker-signal stimulus increased, consistent with a decay of the efferent effect. Human auditory efferent activation linearizes the cochlear response for mid-level sounds while reducing maximum gain. PMID:25392499
Gender differences in children's voice use in a day care environment.
Nygren, Mariana; Tyboni, Mikaela; Lindström, Fredric; McAllister, Anita; van Doorn, Jan
2012-11-01
The prevalence of dysphonia is higher in boys than in girls before puberty. This could be because of the differences in boys' and girls' voice use. Previous research on gender differences in prepubescent children's voice parameters has been contradictory. Most studies have focused on examining fundamental frequency. The purpose of this study was to investigate voice use in boys and girls in a day care environment based on the voice parameters fundamental frequency (Hz), vocal intensity (dB SPL), and phonation time (%) and to ascertain whether there were any significant gender differences. Prospective comparative design. The study was conducted in a day care environment where 30 children (17 boys and 13 girls aged 4-5 years) participated. The participants' voices were measured continuously for 4 hours with a voice accumulator that registered fundamental frequency, vocal intensity level, phonation time, and background noise. Mean (standard deviation) fundamental frequency was 310 (22) and 321 (16) Hz, vocal intensity was 93 (4) and 91 (3) dB SPL, and phonation time was 7.7 (2.0)% and 7.6 (2.5)% for boys and girls, respectively. No differences between genders were statistically significant. The finding of no statistically significant gender differences for measurements of voice parameters in a group of children aged 4-5 years in a day care environment is an important finding that contributes to increased knowledge about young boys' and girls' voice use. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Ultrathin thermoacoustic nanobridge loudspeakers from ALD on polyimide
NASA Astrophysics Data System (ADS)
Brown, J. J.; Moore, N. C.; Supekar, O. D.; Gertsch, J. C.; Bright, V. M.
2016-11-01
The recent development of low-temperature (<200 °C) atomic layer deposition (ALD) for fabrication of freestanding nanostructures has enabled consideration of active device design based on engineered ultrathin films. This paper explores audible sound production from thermoacoustic loudspeakers fabricated from suspended tungsten nanobridges formed by ALD. Additionally, this paper develops an approach to lumped-element modeling for design of thermoacoustic nanodevices and relates the near-field plane wave model of individual transducer beams to the far-field spherical wave sound pressure that can be measured with standard experimental techniques. Arrays of suspended nanobridges with 25.8 nm thickness and sizes as small as 17 μm × 2 μm have been fabricated and demonstrated to produce audible sound using the thermoacoustic effect. The nanobridges were fabricated by ALD of 6.5 nm Al2O3 and 19.3 nm tungsten on sacrificial polyimide, with ALD performed at 130 °C and patterned by standard photolithography. The maximum observed loudspeaker sound pressure level (SPL) is 104 dB, measured at 20 kHz, 9.71 W input power, and 1 cm measurement distance, providing a loudspeaker sensitivity value of ∼64.6 dB SPL/1 mW. Sound production efficiency was measured to vary proportional to frequency f 3 and was directly proportional to input power. The devices in this paper demonstrate industrially feasible nanofabrication of thermoacoustic transducers and a sound production mechanism pertinent to submicron-scale device engineering.
Cho, Jin-Young; Lee, Hyoung-Joo; Jeong, Seul-Ki; Kim, Kwang-Youl; Kwon, Kyung-Hoon; Yoo, Jong Shin; Omenn, Gilbert S; Baker, Mark S; Hancock, William S; Paik, Young-Ki
2015-12-04
Approximately 2.9 billion long base-pair human reference genome sequences are known to encode some 20 000 representative proteins. However, 3000 proteins, that is, ~15% of all proteins, have no or very weak proteomic evidence and are still missing. Missing proteins may be present in rare samples in very low abundance or be only temporarily expressed, causing problems in their detection and protein profiling. In particular, some technical limitations cause missing proteins to remain unassigned. For example, current mass spectrometry techniques have high limits and error rates for the detection of complex biological samples. An insufficient proteome coverage in a reference sequence database and spectral library also raises major issues. Thus, the development of a better strategy that results in greater sensitivity and accuracy in the search for missing proteins is necessary. To this end, we used a new strategy, which combines a reference spectral library search and a simulated spectral library search, to identify missing proteins. We built the human iRefSPL, which contains the original human reference spectral library and additional peptide sequence-spectrum match entries from other species. We also constructed the human simSPL, which contains the simulated spectra of 173 907 human tryptic peptides determined by MassAnalyzer (version 2.3.1). To prove the enhanced analytical performance of the combination of the human iRefSPL and simSPL methods for the identification of missing proteins, we attempted to reanalyze the placental tissue data set (PXD000754). The data from each experiment were analyzed using PeptideProphet, and the results were combined using iProphet. For the quality control, we applied the class-specific false-discovery rate filtering method. All of the results were filtered at a false-discovery rate of <1% at the peptide and protein levels. The quality-controlled results were then cross-checked with the neXtProt DB (2014-09-19 release). The two spectral libraries, iRefSPL and simSPL, were designed to ensure no overlap of the proteome coverage. They were shown to be complementary to spectral library searching and significantly increased the number of matches. From this trial, 12 new missing proteins were identified that passed the following criterion: at least 2 peptides of 7 or more amino acids in length or one of 9 or more amino acids in length with one or more unique sequences. Thus, the iRefSPL and simSPL combination can be used to help identify peptides that have not been detected by conventional sequence database searches with improved sensitivity and a low error rate.
Sarria-S, Fabio A.; Morris, Glenn K.; Windmill, James F. C.; Jackson, Joseph; Montealegre-Z, Fernando
2014-01-01
This article reports the discovery of a new genus and three species of predaceous katydid (Insecta: Orthoptera) from Colombia and Ecuador in which males produce the highest frequency ultrasonic calling songs so far recorded from an arthropod. Male katydids sing by rubbing their wings together to attract distant females. Their song frequencies usually range from audio (5 kHz) to low ultrasonic (30 kHz). However, males of Supersonus spp. call females at 115 kHz, 125 kHz, and 150 kHz. Exceeding the human hearing range (50 Hz–20 kHz) by an order of magnitude, these insects also emit their ultrasound at unusually elevated sound pressure levels (SPL). In all three species these calls exceed 110 dB SPL rms re 20 µPa (at 15 cm). Males of Supersonus spp. have unusually reduced forewings (<0.5 mm2). Only the right wing radiates appreciable sound, the left bears the file and does not show a particular resonance. In contrast to most katydids, males of Supersonus spp. position and move their wings during sound production so that the concave aspect of the right wing, underlain by the insect dorsum, forms a contained cavity with sharp resonance. The observed high SPL at extreme carrier frequencies can be explained by wing anatomy, a resonant cavity with a membrane, and cuticle deformation. PMID:24901234
Korhonen, Petri; Kuk, Francis; Seper, Eric; Mørkebjerg, Martin; Roikjer, Majken
2017-01-01
Wind noise is a common problem reported by hearing aid wearers. The MarkeTrak VIII reported that 42% of hearing aid wearers are not satisfied with the performance of their hearing aids in situations where wind is present. The current study investigated the effect of a new wind noise attenuation (WNA) algorithm on subjective annoyance and speech recognition in the presence of wind. A single-blinded, repeated measures design was used. Fifteen experienced hearing aid wearers with bilaterally symmetrical (≤10 dB) mild-to-moderate sensorineural hearing loss participated in the study. Subjective rating for wind noise annoyance was measured for wind presented alone from 0° and 290° at wind speeds of 4, 5, 6, 7, and 10 m/sec. Phoneme identification performance was measured using Widex Office of Clinical Amplification Nonsense Syllable Test presented at 60, 65, 70, and 75 dB SPL from 270° in the presence of wind originating from 0° at a speed of 5 m/sec. The subjective annoyance from wind noise was reduced for wind originating from 0° at wind speeds from 4 to 7 m/sec. The largest improvement in phoneme identification with the WNA algorithm was 48.2% when speech was presented from 270° at 65 dB SPL and the wind originated from 0° azimuth at 5 m/sec. The WNA algorithm used in this study reduced subjective annoyance for wind speeds ranging from 4 to 7 m/sec. The algorithm was effective in improving speech identification in the presence of wind originating from 0° at 5 m/sec. These results suggest that the WNA algorithm used in the current study could expand the range of real-life situations where a hearing-impaired person can use the hearing aid optimally. American Academy of Audiology
Tonotopically Ordered Traveling Waves in the Hearing Organs of Bushcrickets in-vivo
NASA Astrophysics Data System (ADS)
Udayashankar, Arun Palghat; Kössl, Manfred; Nowotny, Manuela
2011-11-01
Experimental investigation of auditory mechanics in the mammalian cochlea has been difficult to address in-vivo due to its secure housing inside the temporal bone. Here we studied the easily accessible hearing organ of bushcrickets, located in their forelegs, known as the crista acustica. A characteristic feature of the organ is that it is lined with an array of auditory receptors in a tonotopic fashion with lower frequencies processed at the proximal part and higher frequencies at the distal part of the foreleg. Each receptor cell is associated with so called cap cells. The cap cells, graded in size, are directly involved in the mechanics of transduction along with the part of the acoustic trachea that supports the cap cells. Functional similarities between the crista acustica and the vertebrate cochlea such as frequency selectivity and distortion product otoacoustic emissions have been well documented. In this study we used laser Doppler vibrometry to study the mechanics of the organ and observed sound induced traveling waves (TW) along it's length. Frequency representation was tonotopic with TW propagating from the high frequency to the low frequency region of the organ similar to the situation in the cochlea. Traveling wave velocity increased monotonically from 4 to 12 m/s for a frequency range of 6 to 60 kHz, reflecting a smaller topographic spread (organ length: 1 mm) compared to the guinea pig cochlea (organ length: 18 mm). The wavelength of the traveling wave decreased monotonically from 0.67 mm to 0.27 mm for the same frequency range. Vibration velocity of the organ reached noise threshold levels (10 μm/s) at 30 dB SPL for a frequency of 21 kHz. A small non-linear compression (73 dB increase in velocity for an 80 dB increase in SPL) was also observed at the 21 kHz. Our results indicate that bushcrickets can be a good model system for exploration of auditory mechanics in-vivo.
The Use of Drugs to Reduce Hearing Loss Following Acute Acoustic Trama
2012-07-01
noise exposure: (1) L-N- acetylcysteine (L-NAC); (2) D-Methionine (D-MET); (3) Ebselen SPI-1005; (4) Acetyl-L-carnitine (ALCAR) and (5) Src-PTK inhibitor...exposed to a 4.0 kHz octave band of noise for 6 hours at 105 dB SPL: (1) L-N- acetylcysteine (L-NAC); (2) D-Methionine (D-MET); (3) Ebselen SPI-1005...effectively absent or severely depressed from 2 kHz and above (Figs. 14 & 15). Individual cochleograms for this group are shown in Figure 16. The
2017-03-31
dB Sound Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme Test (MRT) score as listed...below. Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a minimum of ten talkers and of ten...listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication amplification. Test must include the configurations
Lapsley Miller, Judi A; Reed, Charlotte M; Robinson, Sarah R; Perez, Zachary D
2018-02-21
Clinical pure-tone audiometry is conducted using stimuli delivered through supra-aural headphones or insert earphones. The stimuli are calibrated in an acoustic (average ear) coupler. Deviations in individual-ear acoustics from the coupler acoustics affect test validity, and variations in probe insertion and headphone placement affect both test validity and test-retest reliability. Using an insert earphone designed for otoacoustic emission testing, which contains a microphone and loudspeaker, an individualized in-the-ear calibration can be calculated from the ear-canal sound pressure measured at the microphone. However, the total sound pressure level (SPL) measured at the microphone may be affected by standing-wave nulls at higher frequencies, producing errors in stimulus level of up to 20 dB. An alternative is to calibrate using the forward pressure level (FPL) component, which is derived from the total SPL using a wideband acoustic immittance measurement, and represents the pressure wave incident on the eardrum. The objective of this study is to establish test-retest reliability for FPL calibration of pure-tone audiometry stimuli, compared with in-the-ear and coupler sound pressure calibrations. The authors compared standard audiometry using a modern clinical audiometer with TDH-39P supra-aural headphones calibrated in a coupler to a prototype audiometer with an ER10C earphone calibrated three ways: (1) in-the-ear using the total SPL at the microphone, (2) in-the-ear using the FPL at the microphone, and (3) in a coupler (all three are derived from the same measurement). The test procedure was similar to that commonly used in hearing-conservation programs, using pulsed-tone test frequencies at 0.5, 1, 2, 3, 4, 6, and 8 kHz, and an automated modified Hughson-Westlake audiometric procedure. Fifteen adult human participants with normal to mildly-impaired hearing were selected, and one ear from each was tested. Participants completed 10 audiograms on each system, with test-order randomly varied and with headphones and earphones refitted by the tester between tests. Fourteen of 15 ears had standing-wave nulls present between 4 and 8 kHz. The mean intrasubject SD at 6 and 8 kHz was lowest for the FPL calibration, and was comparable with the low-frequency reliability across calibration methods. This decrease in variability translates to statistically-derived significant threshold shift criteria indicating that 15 dB shifts in hearing can be reliably detected at 6 and 8 kHz using FPL-calibrated ER10C earphones, compared with 20 to 25 dB shifts using standard TDH-39P headphones with a coupler calibration. These results indicate that reliability is better with insert earphones, especially with in-the-ear FPL calibration, compared with a standard clinical audiometer with supra-aural headphones. However, in-the-ear SPL calibration should not be used due to its sensitivity to standing waves. The improvement in reliability is clinically meaningful, potentially allowing hearing-conservation programs to more confidently determine significant threshold shifts at 6 kHz-a key frequency for the early detection of noise-induced hearing loss.
Kleber, C; Buschmann, C T
2013-06-01
Periportal edema (PPE) of the liver in multislice computed tomography (MS-CT) scans that develops immediately (primary PPE [pPPE]) or later (secondary PPE [sPPE]) is not uncommon in severe trauma patients. Although PPE may serve as a marker for blunt abdominal trauma (22-31 % of cases), distinct causes and clinical implications of PPE are unclear. We analyzed the incidence of pPPE and sPPE in 68 MS-CT scans in severe trauma patients (2007-2009). Exclusion criteria were severely burned patients and patients with preexistent liver diseases predisposing to PPE. We divided PPE+ patients into two subpopulations-either initial/primary PPE (pPPE+) or later/secondary PPE (sPPE+). Further patient data were collected and statistically analyzed. PPE+ was found in 27.9 % (n = 19). Females predominated (p = 0.01), and PPE+ patients presented with a significantly better pH at admission (p = 0.008). The total amount of volume resuscitation (1,983 ± 1,155 ml; p = 0.02) and crystalloids (1,117 ± 796 ml; p = 0.006) administered before MS-CT scans was significantly higher in PPE+, whereas the amount of administered colloids (797 ± 640 ml) showed no significant difference in both groups. PPE+ was not associated with further patient data, i.e., trauma mechanism, injury severity, prognosis-relevant factors, adverse clinical events, or mortality. pPPE+ in MS-CT may serve as a surrogate parameter for intravenous volume load and/or venous congestion, and sPPE+ may also indicate venous congestion and right heart failure after severe trauma. In severe trauma patients with pPPE+/sPPE+ in MS-CT scans, causes of PPE relating to intravenous fluid overload and/or venous congestion should be excluded or treated.
Normative behavioral thresholds for short tone-bursts.
Beattie, R C; Rochverger, I
2001-10-01
Although tone-bursts have been commonly used in auditory brainstem response (ABR) evaluations for many years, national standards describing normal calibration values have not been established. This study was designed to gather normative threshold data to establish a physical reference for tone-burst stimuli that can be reproduced across clinics and laboratories. More specifically, we obtained norms for 3-msec tone-bursts presented at two repetition rates (9.3/sec and 39/sec), two gating functions (Trapezoid and Blackman), and four frequencies (500, 1000, 2000, and 4000 Hz). Our results are specified using three physical references: dB peak sound pressure level, dB peak-to-peak equivalent sound pressure level, and dB SPL (fast meter response, rate = 50 stimuli/sec). These data are offered for consideration when calibrating ABR equipment. The 39/sec stimulus rate yielded tone-burst thresholds that were approximately 3 dB lower than the 9.3/sec rate. The improvement in threshold with increasing stimulus rate may reflect the ability of the auditory system to integrate energy that occurs within a time interval of 200 to 500 msec (temporal integration). The Trapezoid gating function yielded thresholds that averaged 1.4 dB lower than the Blackman function. Although these differences are small and of little clinical importance, the cumulative effects of several instrument and/or procedural variables may yield clinically important differences.
Lesinskas, E; Stankeviciute, V; Petrulionis, M
2012-12-01
To present results for the auditory rehabilitation of patients with Treacher Collins syndrome with bilateral osseous atresia, using middle-ear implantation with a Vibrant Soundbridge. Three patients underwent vibroplasty for aural atresia with moderate to severe conductive hearing loss. The pre-operative Jahrsdoerfer radiological score was 4 for all patients. Patients underwent active middle-ear implantation of a Vibrant Soundbridge implant (coupling the floating mass transducer to the rudimentary stapes or footplate distally, and positioning it adjacent to the round window membrane proximally), with audiological analysis as follow up. After implant activation, the mean air conduction threshold ± standard deviation decreased to 22.8 ± 5.5 dB HL, representing a mean functional gain of 44.5 dB. The mean word recognition score (for bisyllabic words at 65 dB SPL) increased from 0 to 97 per cent. Vibrant Soundbridge implantation is an effective hearing rehabilitation procedure in patients with Treacher Collins syndrome with bilateral osseous atresia. This is a versatile implant which can achieve coupling even in cases of severe middle-ear malformation.
NASA Technical Reports Server (NTRS)
Fontana, R. R.; Hubbard, J. E., Jr.
1983-01-01
Mini-tuft and smoke flow visualization techniques have been developed for the investigation of model helicopter rotor blade vortex interaction noise at low tip speeds. These techniques allow the parameters required for calculation of the blade vortex interaction noise using the Widnall/Wolf model to be determined. The measured acoustics are compared with the predicted acoustics for each test condition. Under the conditions tested it is determined that the dominating acoustic pulse results from the interaction of the blade with a vortex 1-1/4 revolutions old at an interaction angle of less than 8 deg. The Widnall/Wolf model predicts the peak sound pressure level within 3 dB for blade vortex separation distances greater than 1 semichord, but it generally over predicts the peak S.P.L. by over 10 dB for blade vortex separation distances of less than 1/4 semichord.
Gökdoğan, Çağıl; Gökdoğan, Ozan; Şahin, Esra; Yılmaz, Metin
2014-01-01
This study aims to evaluate phonetogram data of the students in the department of music who passed the entrance exam. The phonetogram data of 44 individuals with a good voice quality in the department of music and age-matched individuals who were not trained in the field of music or not involved in music amateurish as the control group were compared. The voice of both groups were recorded using the voice range profile within the scope of Kay Elemetrics CSL (Model 4300 B) programmed. There was a significant difference in the voice range profile parameters including max Fo, Fo range, Fo range (St), min dB SPL, and max dB sound pressure level (p<0.05). Our study results suggest that the voice interval of the department of music is higher than the control group and that plays a major role in their acceptance to the department of music.
Newman, Andrew J; Hayes, Sarah H; Rao, Abhiram S; Allman, Brian L; Manohar, Senthilvelan; Ding, Dalian; Stolzberg, Daniel; Lobarinas, Edward; Mollendorf, Joseph C; Salvi, Richard
2015-03-15
Military personnel and civilians living in areas of armed conflict have increased risk of exposure to blast overpressures that can cause significant hearing loss and/or brain injury. The equipment used to simulate comparable blast overpressures in animal models within laboratory settings is typically very large and prohibitively expensive. To overcome the fiscal and space limitations introduced by previously reported blast wave generators, we developed a compact, low-cost blast wave generator to investigate the effects of blast exposures on the auditory system and brain. The blast wave generator was constructed largely from off the shelf components, and reliably produced blasts with peak sound pressures of up to 198dB SPL (159.3kPa) that were qualitatively similar to those produced from muzzle blasts or explosions. Exposure of adult rats to 3 blasts of 188dB peak SPL (50.4kPa) resulted in significant loss of cochlear hair cells, reduced outer hair cell function and a decrease in neurogenesis in the hippocampus. Existing blast wave generators are typically large, expensive, and are not commercially available. The blast wave generator reported here provides a low-cost method of generating blast waves in a typical laboratory setting. This compact blast wave generator provides scientists with a low cost device for investigating the biological mechanisms involved in blast wave injury to the rodent cochlea and brain that may model many of the damaging effects sustained by military personnel and civilians exposed to intense blasts. Copyright © 2015 Elsevier B.V. All rights reserved.
Newman, Andrew J.; Hayes, Sarah H.; Rao, Abhiram S.; Allman, Brian L.; Manohar, Senthilvelan; Ding, Dalian; Stolzberg, Daniel; Lobarinas, Edward; Mollendorf, Joseph C.; Salvi, Richard
2015-01-01
Background Military personnel and civilians living in areas of armed conflict have increased risk of exposure to blast overpressures that can cause significant hearing loss and/or brain injury. The equipment used to simulate comparable blast overpressures in animal models within laboratory settings is typically very large and prohibitively expensive. New Method To overcome the fiscal and space limitations introduced by previously reported blast wave generators, we developed a compact, low-cost blast wave generator to investigate the effects of blast exposures on the auditory system and brain. Results The blast wave generator was constructed largely from off the shelf components, and reliably produced blasts with peak sound pressures of up to 198 dB SPL (159.3 kPa) that were qualitatively similar to those produced from muzzle blasts or explosions. Exposure of adult rats to 3 blasts of 188 dB peak SPL (50.4 kPa) resulted in significant loss of cochlear hair cells, reduced outer hair cell function and a decrease in neurogenesis in the hippocampus. Comparison to existing methods Existing blast wave generators are typically large, expensive, and are not commercially available. The blast wave generator reported here provides a low-cost method of generating blast waves in a typical laboratory setting. Conclusions This compact blast wave generator provides scientists with a low cost device for investigating the biological mechanisms involved in blast wave injury to the rodent cochlea and brain that may model many of the damaging effects sustained by military personnel and civilians exposed to intense blasts. PMID:25597910
Greene, Nathaniel T.; Mattingly, Jameson K.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.; Cass, Stephen P.
2015-01-01
Hypothesis Cochlear implants (CI) designed for hearing preservation will not alter mechanical properties of the middle and inner ear as measured by intracochlear pressure (PIC) and stapes velocity (Vstap). Background CIs designed to provide combined electrical and acoustic stimulation (EAS) are now available. To maintain functional acoustic hearing, it is important to know if a CI electrode can alter middle or inner ear mechanics, as any alteration could contribute to elevated low-frequency thresholds in EAS patients. Methods Seven human cadaveric temporal bones were prepared, and pure-tone stimuli from 120Hz–10kHz were presented at a range of intensities up to 110 dB SPL. PIC in the scala vestibuli (PSV) and tympani (PST) were measured with fiber-optic pressure sensors concurrently with VStap using laser Doppler vibrometry. Five CI electrodes from two different manufacturers, with varying dimensions were inserted via a round window approach at six different depths (16–25 mm). Results The responses of PIC and VStap to acoustic stimulation were assessed as a function of stimulus frequency, normalized to SPL in the external auditory canal (EAC), in baseline and electrode inserted conditions. Responses measured with electrodes inserted were generally within ~5 dB of baseline, indicating little effect of cochlear implant electrode insertion on PIC and VStap. Overall, mean differences across conditions were small for all responses, and no substantial differences were consistently visible across electrode types. Conclusions Results suggest that the influence of a CI electrode on middle and inner ear mechanics is minimal, despite variation in electrode lengths and configurations. PMID:26333018
Thermoacoustic sound projector: exceeding the fundamental efficiency of carbon nanotubes.
Aliev, Ali E; Codoluto, Daniel; Baughman, Ray H; Ovalle-Robles, Raquel; Inoue, Kanzan; Romanov, Stepan A; Nasibulin, Albert G; Kumar, Prashant; Priya, Shashank; Mayo, Nathanael K; Blottman, John B
2018-08-10
The combination of smooth, continuous sound spectra produced by a sound source having no vibrating parts, a nanoscale thickness of a flexible active layer and the feasibility of creating large, conformal projectors provoke interest in thermoacoustic phenomena. However, at low frequencies, the sound pressure level (SPL) and the sound generation efficiency of an open carbon nanotube sheet (CNTS) is low. In addition, the nanoscale thickness of fragile heating elements, their high sensitivity to the environment and the high surface temperatures practical for thermoacoustic sound generation necessitate protective encapsulation of a freestanding CNTS in inert gases. Encapsulation provides the desired increase of sound pressure towards low frequencies. However, the protective enclosure restricts heat dissipation from the resistively heated CNTS and the interior of the encapsulated device. Here, the heat dissipation issue is addressed by short pulse excitations of the CNTS. An overall increase of energy conversion efficiency by more than four orders (from 10 -5 to 0.1) and the SPL of 120 dB re 20 μPa @ 1 m in air and 170 dB re 1 μPa @ 1 m in water were demonstrated. The short pulse excitation provides a stable linear increase of output sound pressure with substantially increased input power density (>2.5 W cm -2 ). We provide an extensive experimental study of pulse excitations in different thermodynamic regimes for freestanding CNTSs with varying thermal inertias (single-walled and multiwalled with varying diameters and numbers of superimposed sheet layers) in vacuum and in air. The acoustical and geometrical parameters providing further enhancement of energy conversion efficiency are discussed.
Thermocron iButton and iBBat temperature dataloggers emit ultrasound.
Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H
2009-10-01
Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.
Popov, Vladimir V; Supin, Alexander Ya; Rozhnov, Viatcheslav V; Nechaev, Dmitry I; Sysueva, Evgenia V
2014-05-15
The influence of fatiguing sound level and duration on post-exposure temporary threshold shift (TTS) was investigated in two beluga whales (Delphinapterus leucas). The fatiguing sound was half-octave noise with a center frequency of 22.5 kHz. TTS was measured at a test frequency of 32 kHz. Thresholds were measured by recording rhythmic evoked potentials (the envelope following response) to a test series of short (eight cycles) tone pips with a pip rate of 1000 s(-1). TTS increased approximately proportionally to the dB measure of both sound pressure (sound pressure level, SPL) and duration of the fatiguing noise, as a product of these two variables. In particular, when the noise parameters varied in a manner that maintained the product of squared sound pressure and time (sound exposure level, SEL, which is equivalent to the overall noise energy) at a constant level, TTS was not constant. Keeping SEL constant, the highest TTS appeared at an intermediate ratio of SPL to sound duration and decreased at both higher and lower ratios. Multiplication (SPL multiplied by log duration) better described the experimental data than an equal-energy (equal SEL) model. The use of SEL as a sole universal metric may result in an implausible assessment of the impact of a fatiguing sound on hearing thresholds in odontocetes, including under-evaluation of potential risks. © 2014. Published by The Company of Biologists Ltd.
Experimental study of acoustic agglomeration and fragmentation on coal-fired ash
NASA Astrophysics Data System (ADS)
Shen, Guoqing; Huang, Xiaoyu; He, Chunlong; Zhang, Shiping; An, Liansuo; Wang, Liang; Chen, Yanqiao; Li, Yongsheng
2018-02-01
As the major part of air pollution, inhalable particles, especially fine particles are doing great harm to human body due to smaller particle size and absorption of hazardous components. However, the removal efficiency of current particles filtering devices is low. Acoustic agglomeration is considered as a very effective pretreatment technique for removing particles. Fine particles collide, agglomerate and grow up in the sound field and the fine particles can be removed by conventional particles devices easily. In this paper, the agglomeration and fragmentation of 3 different kinds of particles with different size distributions are studied experimentally in the sound field. It is found that there exists an optimal frequency at 1200 Hz for different particles. The agglomeration efficiency of inhalable particles increases with SPL increasing for the unimodal particles with particle diameter less than 10 μm. For the bimodal particles, the optimal SPLs are 115 and 120 dB with the agglomeration efficiencies of 25% and 55%. A considerable effectiveness of agglomeration could only be obtained in a narrow SPL range and it decreases significantly over the range for the particles fragmentation.
Visualization Measurement of Streaming Flows Associated with a Single-Acoustic Levitator
NASA Astrophysics Data System (ADS)
Hasegawa, Koji; Abe, Yutaka; Kaneko, Akiko; Yamamoto, Yuji; Aoki, Kazuyoshi
2009-08-01
The purpose of the study is to experimentally investigate flow fields generated by an acoustic levitator. This flow field has been observed using flow visualization, PIV method. In the absent of a drop, the flow field was strongly influenced by sound pressure level (SPL). In light of the interfacial stability of a levitated drop, SPL was set at 161-163 [dB] in our experiments. In the case of any levitated drop at a pressure node of a standing wave, the toroidal vortices were appeared around a drop and clearly observed the flow fields around the drop by PIV measurement. It is found that the toroidal vortices around a levitated drop were strongly affected by the viscosity of a drop. For more detailed research, experiments in the reduced gravity were conducted with aircraft parabolic flights. By comparison with experimental results in the earth and reduced gravity, it is also indicated that the configuration of the external flow field around a drop is most likely to be affected by a position of a drop as well.
Kwon, Jennie H; Burnham, Carey-Ann D; Reske, Kimberly A; Liang, Stephen Y; Hink, Tiffany; Wallace, Meghan A; Shupe, Angela; Seiler, Sondra; Cass, Candice; Fraser, Victoria J; Dubberke, Erik R
2017-09-01
OBJECTIVE To evaluate healthcare worker (HCW) risk of self-contamination when donning and doffing personal protective equipment (PPE) using fluorescence and MS2 bacteriophage. DESIGN Prospective pilot study. SETTING Tertiary-care hospital. PARTICIPANTS A total of 36 HCWs were included in this study: 18 donned/doffed contact precaution (CP) PPE and 18 donned/doffed Ebola virus disease (EVD) PPE. INTERVENTIONS HCWs donned PPE according to standard protocols. Fluorescent liquid and MS2 bacteriophage were applied to HCWs. HCWs then doffed their PPE. After doffing, HCWs were scanned for fluorescence and swabbed for MS2. MS2 detection was performed using reverse transcriptase PCR. The donning and doffing processes were videotaped, and protocol deviations were recorded. RESULTS Overall, 27% of EVD PPE HCWs and 50% of CP PPE HCWs made ≥1 protocol deviation while donning, and 100% of EVD PPE HCWs and 67% of CP PPE HCWs made ≥1 protocol deviation while doffing (P=.02). The median number of doffing protocol deviations among EVD PPE HCWs was 4, versus 1 among CP PPE HCWs. Also, 15 EVD PPE protocol deviations were committed by doffing assistants and/or trained observers. Fluorescence was detected on 8 EVD PPE HCWs (44%) and 5 CP PPE HCWs (28%), most commonly on hands. MS2 was recovered from 2 EVD PPE HCWs (11%) and 3 CP PPE HCWs (17%). CONCLUSIONS Protocol deviations were common during both EVD and CP PPE doffing, and some deviations during EVD PPE doffing were committed by the HCW doffing assistant and/or the trained observer. Self-contamination was common. PPE donning/doffing are complex and deserve additional study. Infect Control Hosp Epidemiol 2017;38:1077-1083.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise.
Nechaev, Dmitry I; Milekhina, Olga N; Supin, Alexander Ya
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise
Nechaev, Dmitry I.; Milekhina, Olga N.; Supin, Alexander Ya.
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels. PMID:26462066
Hodgetts, William; Scott, Dylan; Maas, Patrick; Westover, Lindsey
2018-03-23
To determine if a newly-designed, forehead-mounted surface microphone would yield equivalent estimates of audibility when compared to audibility measured with a skull simulator for adult bone conduction users. Data was analyzed using a within subjects, repeated measures design. There were two different sensors (skull simulator and surface microphone) measuring the same hearing aid programmed to the same settings for all subjects. We were looking for equivalent results. Twenty-one adult percutaneous bone conduction users (12 females and 9 males) were recruited for this study. Mean age was 54.32 years with a standard deviation of 14.51 years. Nineteen of the subjects had conductive/mixed hearing loss and two had single-sided deafness. To define audibility, we needed to establish two things: (1) in situ-level thresholds at each audiometric frequency in force (skull simulator) and in sound pressure level (SPL; surface microphone). Next, we measured the responses of the preprogrammed test device in force on the skull simulator and in SPL on the surface mic in response to pink noise at three input levels: 55, 65, and 75 dB SPL. The skull simulator responses were converted to real head force responses by means of an individual real head to coupler difference transform. Subtracting the real head force level thresholds from the real head force output of the test aid yielded the audibility for each audiometric frequency for the skull simulator. Subtracting the SPL thresholds from the surface microphone from the SPL output of the test aid yielded the audibility for each audiometric frequency for the surface microphone. The surface microphone was removed and retested to establish the test-retest reliability of the tool. We ran a 2 (sensor) × 3 (input level) × 10 (frequency) mixed analysis of variance to determine if there were any significant main effects and interactions. There was a significant three-way interaction, so we proceeded to explore our planned comparisons. There were 90 planned comparisons of interest, three at each frequency (3 × 10) for the three input levels (30 × 3). Therefore, to minimize a type 1 error associated with multiple comparisons, we adjusted alpha using the Holm-Bonferroni method. There were five comparisons that yielded significant differences between the skull simulator and surface microphone (test and retest) in the estimation of audibility. However, the mean difference in these effects was small at 3.3 dB. Both sensors yielded equivalent results for the majority of comparisons. Models of bone conduction devices that have intact skin cannot be measured with the skull simulator. This study is the first to present and evaluate a new tool for bone conduction verification. The surface microphone is capable of yielding equivalent audibility measurements as the skull simulator for percutaneous bone conduction users at multiple input levels. This device holds potential for measuring other bone conduction devices (Sentio, BoneBridge, Attract, Soft headband devices) that do not have a percutaneous implant.
2017-03-01
in an environment 71-115 dB Sound Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme... Test (MRT) score as listed below. Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a...minimum of ten talkers and of ten listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication amplification. Test must
Henry, Kenneth S.; Kale, Sushrut; Scheidt, Ryan E.; Heinz, Michael G.
2011-01-01
Non-invasive auditory brainstem responses (ABRs) are commonly used to assess cochlear pathology in both clinical and research environments. In the current study, we evaluated the relationship between ABR characteristics and more direct measures of cochlear function. We recorded ABRs and auditory nerve (AN) single-unit responses in seven chinchillas with noise induced hearing loss. ABRs were recorded for 1–8 kHz tone burst stimuli both before and several weeks after four hours of exposure to a 115 dB SPL, 50 Hz band of noise with a center frequency of 2 kHz. Shifts in ABR characteristics (threshold, wave I amplitude, and wave I latency) following hearing loss were compared to AN-fiber tuning curve properties (threshold and frequency selectivity) in the same animals. As expected, noise exposure generally resulted in an increase in ABR threshold and decrease in wave I amplitude at equal SPL. Wave I amplitude at equal sensation level (SL), however, was similar before and after noise exposure. In addition, noise exposure resulted in decreases in ABR wave I latency at equal SL and, to a lesser extent, at equal SPL. The shifts in ABR characteristics were significantly related to AN-fiber tuning curve properties in the same animal at the same frequency. Larger shifts in ABR thresholds and ABR wave I amplitude at equal SPL were associated with greater AN threshold elevation. Larger reductions in ABR wave I latency at equal SL, on the other hand, were associated with greater loss of AN frequency selectivity. This result is consistent with linear systems theory, which predicts shorter time delays for broader peripheral frequency tuning. Taken together with other studies, our results affirm that ABR thresholds and wave I amplitude provide useful estimates of cochlear sensitivity. Furthermore, comparisons of ABR wave I latency to normative data at the same SL may prove useful for detecting and characterizing loss of cochlear frequency selectivity. PMID:21699970
Use of protective equipment by adolescents in inline skating, skateboarding, and snowboarding.
Kroncke, Erica L; Niedfeldt, Mark W; Young, Craig C
2008-01-01
Determine the frequency of personal protective equipment (PPE) use in adolescent inline skaters, skateboarders, and snowboarders; explore factors influencing PPE use; identify factors that would influence use; and examine the association of high-risk behaviors and PPE use. Cross-sectional survey. Central/southeast Wisconsin. Participants 13-18 years-old. None. Independent variables = age, gender, sport. None. Dependent variables = PPE use, factors influencing use, and frequency of other high-risk behaviors. The mean age of 333 participiants was 14.9 years. Adolescents wore considerably less PPE than recommended. Inline skaters wore the most; snowboarders the least. The most common reasons adolescents wore PPE were parents, peers, and rule/requirement. Younger adolescents cited parents more often than older adolescents as a factor for PPE use. Discomfort and lack of perceived need were the most common reasons for nonuse. Sustaining/witnessing an accident was the most common reason that would convince adolescents to wear PPE. Almost half of adolescents reported nothing would convince them to wear PPE. Younger adolescents wore more PPE than older adolescents. An association was seen between PPE use in all sports and bicycle helmets. An inverse relationship was found for tobacco and helmet use among skaters, as well as alcohol and helmet use in skateboarders. Adolescents underuse PPE. PPE reinforcement by parents/peers, encouraging bike helmets, manufacturing more comfortable gear, educating adolescents, and instituting PPE requirements in public areas may increase compliance. This could lead to decreased injuries. Physicians should discuss PPE with their patients/families. There may be an association between PPE use in extreme sports and decreased high-risk health behaviors.
Lankford, James E.; Meinke, Deanna K.; Flamme, Gregory A.; Finan, Donald S.; Stewart, Michael; Tasko, Stephen; Murphy, William J.
2016-01-01
Objective To characterize the impulse noise exposure and auditory risk for air rifle users for both youth and adults. Design Acoustic characteristics were examined and the auditory risk estimates were evaluated using contemporary damage-risk criteria for unprotected adult listeners and the 120-dB peak limit and LAeq75 exposure limit suggested by the World Health Organization (1999) for children. Study sample Impulses were generated by 9 pellet air rifles and 1 BB air rifle. Results None of the air rifles generated peak levels that exceeded the 140 dB peak limit for adults and 8 (80%) exceeded the 120 dB peak SPL limit for youth. In general, for both adults and youth there is minimal auditory risk when shooting less than 100 unprotected shots with pellet air rifles. Air rifles with suppressors were less hazardous than those without suppressors and the pellet air rifles with higher velocities were generally more hazardous than those with lower velocities. Conclusion To minimize auditory risk, youth should utilize air rifles with an integrated suppressor and lower velocity ratings. Air rifle shooters are advised to wear hearing protection whenever engaging in shooting activities in order to gain self-efficacy and model appropriate hearing health behaviors necessary for recreational firearm use. PMID:26840923
Active Noise Control of Low Speed Fan Rotor-Stator Modes
NASA Technical Reports Server (NTRS)
Sutliff, Daniel L.; Hu, Ziqiang; Pla, Frederic G.; Heidelberg, Laurence J.
1996-01-01
This report describes the Active Noise Cancellation System designed by General Electric and tested in the NASA Lewis Research Center's 48 inch Active Noise Control Fan. The goal of this study was to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for active noise cancellation of fan tones. The control system is based on a modal control approach. A known acoustic mode propagating in the fan duct is cancelled using an array of flush-mounted compact sound sources. Controller inputs are signals from a shaft encoder and a microphone array which senses the residual acoustic mode in the duct. The canceling modal signal is generated by a modal controller. The key results are that the (6,0) mode was completely eliminated at 920 Hz and substantially reduced elsewhere. The total tone power was reduced 9.4 dB. Farfield 2BPF SPL reductions of 13 dB were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB modal PWL decrease. Global attenuation of PWL was obtained using an actuator and sensor system totally contained within the duct.
Ototoxic occupational exposures for a stock car racing team: I. Noise surveys.
Van Campen, Luann E; Morata, Thais; Kardous, Chucri A; Gwin, Kristin; Wallingford, Kenneth M; Dallaire, Jacques; Alvarez, Frank J
2005-08-01
The National Institute for Occupational Safety and Health (NIOSH) surveyed noise exposure for a professional stock car team at their race shop and during two races at one racetrack. At the team's shop, area sound pressure levels (SPLs) were measured for various work tasks. Equivalent levels (Leqs) ranged from 58 to 104 decibels, A-weighted (dBA). Personal noise dosimetry was conducted for at least one employee for each job description in race car assembly (n = 9). The Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 90 dBA for an 8-hour, 5-dB exchange rate time-weighted average (TWA) was never exceeded, but in two instances values exceeded OSHA's action level of 85 dBA for hearing conservation implementation. The NIOSH recommended exposure limit (REL) of 85 dBA for a 3-dB exchange rate Leq was exceeded for five of the measured jobs. During the races, SPLs averaged above 100 dBA in the pit area where cars undergo adjustments/refueling, both before and during the race. Peak levels reached 140 dB SPL. NIOSH REL was exceeded for every personal noise dosimetry measurement. Recommendations for hearing protection and communication are presented.
Provision Increases Reported PPE Use for Mexican Immigrant Farmworkers: An mHealth Pilot Study.
Snipes, Shedra Amy; Smyth, Joshua M; Murphy, Dennis; Miranda, Patricia Y; Ishino, Francisco Alejandro Montiel
2015-12-01
Personal protective equipment (PPE) reduces pesticide exposures, but many farmworkers complain that it is difficult to obtain. We examined if PPE provision increased usage. We also delivered motivational messaging aimed to promote PPE use. First, we delivered a daily survey through a mobile phone app to assess PPE use. Farmworkers subsequently received a daily, individualized motivational message based on their PPE use and reported difficulties. PPE use was evaluated at baseline and at the close of the study. PPE behaviors improved for gloves (P ≤ 0.01) and safety glasses (P ≤ 0.001). Use of long-sleeved shirts, hats, and long pants were already consistently used at baseline and did not exhibit significant change. Our findings demonstrate that PPE provision and delivery of motivational messaging through mobile phones may increase PPE usage for farmworkers.
Kizawa, K; Kitahara, T; Horii, A; Maekawa, C; Kuramasu, T; Kawashima, T; Nishiike, S; Doi, K; Inohara, H
2010-02-17
Tinnitus is a non-observable phantom sensation. As such, it is a difficult condition to investigate and, to date, no effective treatment has been developed. To approach this phantom sensation, we aimed to develop a rat behavioral model of tinnitus using salicylate, an active component of aspirin known to induce tinnitus. We also aimed to establish a molecular marker of tinnitus by assessing the expression of transient receptor potential cation channel superfamily V-1 (TRPV1) in the rat auditory pathway during salicylate-induced tinnitus. Animals were trained to perform "an active avoidance task": animals were conditioned by electrical footshock to move to the other side of the conditioning box when hearing a sound. Animals received a single injection of saline or salicylate (400 mg/kg i.p.) and false positive responses were measured 2 h after injection as the number of movements during a silent period. The number of responses in salicylate-treated animals was highest when the conditioned stimulus was 60 dB sound pressure level (SPL) and 16 kHz. This indicates that animals could feel tinnitus 2 h after salicylate injection, equivalent to that induced by 60 dB SPL and 16 kHz. By means of real-time PCR and western blot analysis, TRPV1 expression was significantly upregulated in spiral ganglion cells 2 h after salicylate injection and this upregulation together with the increase in the number of false positive responses was significantly suppressed by capsazepine (10 mg/kg i.p.), a specific antagonist of TRPV1. This suggests that salicylate could induce tinnitus through activation of TRPV1 in the rat auditory pathway.
NASA Astrophysics Data System (ADS)
Nam, Hui; Guinan, John J.
2011-11-01
Apical auditory nerve (AN) fibers show two click-response regions that are both strongly inhibited by medial olivocochlear (MOC) efferents: (1) ringing responses from low- level (LL) clicks that are thought to be enhanced by a "cochlear amplifier," and (2) AN initial peak (ANIPr) responses from moderate-to-high level (˜70-100 dB pSPL) rarefaction clicks. Since MOC fibers synapse and act on outer hair cells (OHCs), the MOC inhibition of these responses indicates that OHC processes are heavily involved in the production of both LL and ANIPr responses. Using AN recordings in anesthetized cats, we explored the role of OHC stereocilia position in the production of these click-response regions by presenting rarefaction clicks at different phases of 50 Hz, 70-110 dB SPL bias tones. Bias effects on LL responses followed the traditional biasing pattern of twice-a-bias-tone-cycle suppression with more suppression at one phase than the other. This suppression is attributable to the bias tone moving the OHC stereocilia toward low-slope, saturation regions of the mechano-electric transduction function with the rest position being closer to one saturation region. A somewhat similar pattern was found for ANIPr responses except that the bias phases of the largest suppressions were different in ANIPr versus LL responses, usually by ˜180 degrees. The data are consistent with the LL and ANIPr responses both being due to active processes in OHCs that are controlled by OHC stereocilia position. The different phases of the LL and ANIPr suppressions indicate that different mechanisms, and perhaps different vibration patterns in the organ of Corti, are involved in the production of LL and ANIPr responses.
Voice amplification as a means of reducing vocal load for elementary music teachers.
Morrow, Sharon L; Connor, Nadine P
2011-07-01
Music teachers are over four times more likely than classroom teachers to develop voice disorders and greater than eight times more likely to have voice-related problems than the general public. Research has shown that individual voice-use parameters of phonation time, fundamental frequency and vocal intensity, as well as vocal load as calculated by cycle dose and distance dose are significantly higher for music teachers than their classroom teacher counterparts. Finding effective and inexpensive prophylactic measures to decrease vocal load for music teachers is an important aspect for voice preservation for this group of professional voice users. The purpose of this study was to determine the effects of voice amplification on vocal intensity and vocal load in the workplace as measured using a KayPENTAX Ambulatory Phonation Monitor (APM) (KayPENTAX, Lincoln Park, NJ). Seven music teachers were monitored for 1 workweek using an APM to determine average vocal intensity (dB sound pressure level [SPL]) and vocal load as calculated by cycle dose and distance dose. Participants were monitored a second week while using a voice amplification unit (Asyst ChatterVox; Asyst Communications Company, Inc., Indian Creek, IL). Significant decreases in mean vocal intensity of 7.00-dB SPL (P<0.001) were found using amplification, along with significant decreases (P=0.001) in cycle dose and distance dose. In addition, mean phonation time was found to decrease using amplification (P=0.023). These data suggest that voice amplification may be an effective intervention to decrease the potentially damaging vocal loads experienced by elementary music teachers in the classroom. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Bhagat, Shaum P.; Bass, Johnnie K.; White, Stephanie T.; Qaddoumi, Ibrahim; Wilson, Matthew W.; Wu, Jianrong; Rodriguez-Galindo, Carlos
2016-01-01
Objective Carboplatin is a common chemotherapy agent with potential ototoxic side effects that is used to treat a variety of pediatric cancers, including retinoblastoma. Retinoblastoma is a malignant tumor of the retina that is usually diagnosed in young children. Distortion-product otoacoustic emission tests offer an effective method of monitoring for ototoxicity in young children. This study was designed to compare measurements of distortion-product otoacoustic emissions obtained before and after several courses of carboplatin chemotherapy in order to examine if (a) mean distortion-product otoacoustic emission levels were significantly different; and (b) if criterion reductions in distortion-product otoacoustic emission levels were observed in individual children. Methods A prospective repeated measures study. Ten children with a median age of 7.6 months (range, 3–72 months) diagnosed with unilateral or bilateral retinoblastoma were examined. Distortion-product otoacoustic emissions were acquired from both ears of the children with 65/55 dB SPL primary tones (f2= 793–7996 Hz) and a frequency resolution of 3 points/octave. Distortion-product otoacoustic emission levels in dB SPL were measured before chemotherapy treatment (baseline measurement) and after 3–4 courses of chemotherapy (interim measurement). Comparisons were made between baseline and interim distortion-product otoacoustic emission levels (collapsed across ears). Evidence of ototoxicity was based on criterion reductions (≥ 6 dB) in distortion-product otoacoustic emission levels. Results Significant differences between baseline and interim mean distortion-product otoacoustic emission levels were only observed at f2=7996 Hz. Four children exhibited criterion reductions in distortion-product otoacoustic emission levels. Conclusions Mean distortion-product otoacoustic emission levels at most frequencies were not changed following 3–4 courses of carboplatin chemotherapy in children with retinoblastoma. However, on an individual basis, children receiving higher doses of carboplatin exhibited criterion reductions in distortion-product otoacoustic emission level at several frequencies. These findings suggest that higher doses of carboplatin affect outer hair cell function, and distortion-product otoacoustic emission tests can provide useful information when monitoring children at risk of developing carboplatin ototoxicity. PMID:20667604
Click-Evoked Auditory Efferent Activity: Rate and Level Effects.
Boothalingam, Sriram; Kurke, Julianne; Dhar, Sumitrajit
2018-05-07
There currently are no standardized protocols to evaluate auditory efferent function in humans. Typical tests use broadband noise to activate the efferents, but only test the contralateral efferent pathway, risk activating the middle ear muscle reflex (MEMR), and are laborious for clinical use. In an attempt to develop a clinical test of bilateral auditory efferent function, we have designed a method that uses clicks to evoke efferent activity, obtain click-evoked otoacoustic emissions (CEOAEs), and monitor MEMR. This allows for near-simultaneous estimation of cochlear and efferent function. In the present study, we manipulated click level (60, 70, and 80 dB peak-equivalent sound pressure level [peSPL]) and rate (40, 50, and 62.5 Hz) to identify an optimal rate-level combination that evokes measurable efferent modulation of CEOAEs. Our findings (n = 58) demonstrate that almost all click levels and rates used caused significant inhibition of CEOAEs, with a significant interaction between level and rate effects. Predictably, bilateral activation produced greater inhibition compared to stimulating the efferents only in the ipsilateral or contralateral ear. In examining the click rate-level effects during bilateral activation in greater detail, we observed a 1-dB inhibition of CEOAE level for each 10-dB increase in click level, with rate held constant at 62.5 Hz. Similarly, a 10-Hz increase in rate produced a 0.74-dB reduction in CEOAE level, with click level held constant at 80 dB peSPL. The effect size (Cohen's d) was small for either monaural condition and medium for bilateral, faster-rate, and higher-level conditions. We were also able to reliably extract CEOAEs from efferent eliciting clicks. We conclude that clicks can indeed be profitably employed to simultaneously evaluate cochlear health using CEOAEs as well as their efferent modulation. Furthermore, using bilateral clicks allows the evaluation of both the crossed and uncrossed elements of the auditory efferent nervous system, while yielding larger, more discernible, inhibition of the CEOAEs relative to either ipsilateral or contralateral condition.
Increased medial olivocochlear reflex strength in normal-hearing, noise-exposed humans
2017-01-01
Research suggests that college-aged adults are vulnerable to tinnitus and hearing loss due to exposure to traumatic levels of noise on a regular basis. Recent human studies have associated exposure to high noise exposure background (NEB, i.e., routine noise exposure) with the reduced cochlear output and impaired speech processing ability in subjects with clinically normal hearing sensitivity. While the relationship between NEB and the functions of the auditory afferent neurons are studied in the literature, little is known about the effects of NEB on functioning of the auditory efferent system. The objective of the present study was to investigate the relationship between medial olivocochlear reflex (MOCR) strength and NEB in subjects with clinically normal hearing sensitivity. It was hypothesized that subjects with high NEB would exhibit reduced afferent input to the MOCR circuit which would subsequently lead to reduced strength of the MOCR. In normal-hearing listeners, the study examined (1) the association between NEB and baseline click-evoked otoacoustic emissions (CEOAEs) and (2) the association between NEB and MOCR strength. The MOCR was measured using CEOAEs evoked by 60 dB pSPL linear clicks in a contralateral acoustic stimulation (CAS)-off and CAS-on (a broadband noise at 60 dB SPL) condition. Participants with at least 6 dB signal-to-noise ratio (SNR) in the CAS-off and CAS-on conditions were included for analysis. A normalized CEOAE inhibition index was calculated to express MOCR strength in a percentage value. NEB was estimated using a validated questionnaire. The results showed that NEB was not associated with the baseline CEOAE amplitude (r = -0.112, p = 0.586). Contrary to the hypothesis, MOCR strength was positively correlated with NEB (r = 0.557, p = 0.003). NEB remained a significant predictor of MOCR strength (β = 2.98, t(19) = 3.474, p = 0.003) after the unstandardized coefficient was adjusted to control for effects of smoking, sound level tolerance (SLT) and tinnitus. These data provide evidence that MOCR strength is associated with NEB. The functional significance of increased MOCR strength is discussed. PMID:28886123
Kalaiah, Mohan Kumar; Theruvan, Nikhitha B; Kumar, Kaushlendra; Bhat, Jayashree S
2017-04-01
The present study aimed to investigate the effect of active listening and listening effort on the contralateral suppression of transient evoked otoacoustic emissions (CSTEOAEs). Twenty eight young adults participated in the study. Transient evoked otoacoustic emissions (TEOAEs) were recorded using 'linear' clicks at 60 dB peSPL, in three contralateral noise conditions. In condition 1, TEOAEs were obtained in the presence of white noise in the contralateral ear. While, in condition 2, speech was embedded into white noise at +3, -3, and -9 dB signal-to-noise ratio (SNR) and delivered to the contralateral ear. The SNR was varied to investigate the effect of listening effort on the CSTEOAE. In condition 3, speech was played backwards and embedded into white noise at -3 dB SNR. The conditions 1 and 3 served as passive listening condition and the condition 2 served as active listening condition. In active listening condition, the participants categorized the words in to two groups (e.g., animal and vehicle). CSTEOAE was found to be largest in the presence of white noise, and the amount of CSTEOAE was not significantly different between active and passive listening conditions (condition 2 and 3). Listening effort had an effect on the CSTEOAE, the amount of suppression increased with listening effort, when SNR was decreased from +3 dB to -3 dB. However, when the SNR was further reduced to -9 dB, there was no further increase in the amount of CSTEOAE, instead there was a reduction in the amount of suppression. The findings of the present study show that listening effort might affect CSTEOAE.
Theruvan, Nikhitha B; Kumar, Kaushlendra; Bhat, Jayashree S
2017-01-01
Background and Objectives The present study aimed to investigate the effect of active listening and listening effort on the contralateral suppression of transient evoked otoacoustic emissions (CSTEOAEs). Subjects and Methods Twenty eight young adults participated in the study. Transient evoked otoacoustic emissions (TEOAEs) were recorded using ‘linear’ clicks at 60 dB peSPL, in three contralateral noise conditions. In condition 1, TEOAEs were obtained in the presence of white noise in the contralateral ear. While, in condition 2, speech was embedded into white noise at +3, −3, and −9 dB signal-to-noise ratio (SNR) and delivered to the contralateral ear. The SNR was varied to investigate the effect of listening effort on the CSTEOAE. In condition 3, speech was played backwards and embedded into white noise at −3 dB SNR. The conditions 1 and 3 served as passive listening condition and the condition 2 served as active listening condition. In active listening condition, the participants categorized the words in to two groups (e.g., animal and vehicle). Results CSTEOAE was found to be largest in the presence of white noise, and the amount of CSTEOAE was not significantly different between active and passive listening conditions (condition 2 and 3). Listening effort had an effect on the CSTEOAE, the amount of suppression increased with listening effort, when SNR was decreased from +3 dB to −3 dB. However, when the SNR was further reduced to −9 dB, there was no further increase in the amount of CSTEOAE, instead there was a reduction in the amount of suppression. Conclusions The findings of the present study show that listening effort might affect CSTEOAE. PMID:28417101
Small, Susan A; Smyth, Aisling; Leon, Griselle
2014-01-01
Few studies have investigated effective masking levels (EMLs) needed to isolate the test ear for bone conduction assessments in infants. The objective of this study was to determine EMLs for 500 and 2000 Hz bone conduction auditory steady state responses (ASSRs) to amplitude (AM)/frequency-modulated (FM) stimuli for infants and adults with normal hearing. Maturational factors that contribute to infant-adult differences in EMLs will also be investigated. The present study and previously published 1000 and 4000 Hz EML data will be compared to investigate EML across four frequencies. These findings will provide a starting point for implementing clinical masking for infant bone conduction testing using physiological measures. Participants were 15 infants (7 to 35 weeks) and 15 adults (21 to 56 years) with normal hearing. Bone-conducted single ASSR stimuli (research MASTER) were 100% AM and 25% FM at 85 and 101 Hz for 500 and 2000 Hz carrier frequencies, respectively. They were presented at 25 and 35 dB HL for 500 Hz and at 35 and 45 dB HL for 2000 Hz for both infants and adults (approximately 10 and 20 dB SL at each frequency for infants). Air-conducted narrowband maskers were presented to both ears simultaneously. Real-ear to coupler differences were measured to account for differences in the sound pressure developed in infant and adult ear canals as a result of ear-canal size. Data analyses were conducted for mean EMLs across frequency (500 to 4000 Hz) and between age groups. Masked and unmasked ASSR amplitudes were compared for 500 and 2000 Hz. Both infants and adults required much more masking (25 to 33 dB) to eliminate responses at 500 compared with 2000 Hz. On average, infants required 16 dB more masking at 500 Hz and similar amounts of masking at 2000 Hz compared with adults. When adjusted for ear-canal size and bone conduction sensitivity, the pattern of results did not change. Across all four frequencies, infants showed a systematic decrease in mean EMLs with an increase in frequency; all pair-wise comparisons were significant except 2000 versus 4000 Hz. Adults showed smaller frequency-dependent changes in EML (only significantly greater for 500 versus 2000 Hz and 4000 Hz). When ear-canal size and bone conduction sensitivity were taken into account, only 500 Hz required more masking than other frequencies in infants; there were no significant frequency-dependent trends for adults, although the greater EMLs at 1000 versus 2000 Hz and 4000 Hz approached significance. Unmasked and masked amplitudes tended to be larger for 2000 Hz but not for 500 Hz when comparing infants with adults. EMLs appropriate for infants for bone conduction ASSRs elicited to AM/FM stimuli are considerably higher at 500 compared with 2000 Hz. Infants also need more masking at 500 Hz compared with adults but the same amount of masking at 2000 Hz. Comparisons across four frequencies reveal a systematic decrease in EML with an increase in frequency in infants, which is not apparent in adults. Recommended EMLs for AM/FM bone-conducted ASSR stimuli presented at 35 dB HL for 500, 1000, 2000, and 4000 Hz, respectively, are: (1) infants: 81, 68, 59, and 45 dB SPL, and (2) adults: 66, 63, 59, and 55 dB SPL.
Yue, Erkui; Li, Chao; Li, Yu; Liu, Zhen; Xu, Jian-Hong
2017-07-01
MiR529a affects rice panicle architecture by targeting OsSPL2,OsSPL14 and OsSPL17 genes that could regulate their downstream panicle related genes. The panicle architecture determines the grain yield and quality of rice, which could be regulated by many transcriptional factors. The SQUAMOSA PROMOTER BINDING-LIKE (SPL) transcription factors are involved in the regulation of panicle development, which are targeted by miR156 and miR529. The expression profile demonstrated that miR529a is preferentially expressed in the early panicle of rice and it might regulate panicle development in rice. However, the regulation mechanism of miR529-SPL is still not clear. In this study, we predicted five miR529a putative target genes, OsSPL2, OsSPL14, OsSPL16, OsSPL17 and OsSPL18, while only the expression of OsSPL2, OsSPL14, and OsSPL17 was regulated by miR529a in the rice panicle. Overexpression of miR529a dramatically affected panicle architecture, which was regulated by OsSPL2, OsSPL14, and OsSPL17. Furthermore, the 117, 35, and 25 pathway genes associated with OsSPL2, OsSPL14 and OsSPL17, respectively, were predicted, and they shared 20 putative pathway genes. Our results revealed that miR529a could play a vital role in the regulation of panicle architecture through regulating OsSPL2, OsSPL14, OsSPL17 and the complex networks formed by their pathway and downstream genes. These findings will provide new genetic resources for reshaping ideal plant architecture and breeding high yield rice varieties.
Hearing in alpacas (Vicugna pacos): audiogram, localization acuity, and use of binaural locus cues.
Heffner, Rickye S; Koay, Gimseong; Heffner, Henry E
2014-02-01
Behavioral audiograms and sound localization abilities were determined for three alpacas (Vicugna pacos). Their hearing at a level of 60 dB sound pressure level (SPL) (re 20 μPa) extended from 40 Hz to 32.8 kHz, a range of 9.7 octaves. They were most sensitive at 8 kHz, with an average threshold of -0.5 dB SPL. The minimum audible angle around the midline for 100-ms broadband noise was 23°, indicating relatively poor localization acuity and potentially supporting the finding that animals with broad areas of best vision have poorer sound localization acuity. The alpacas were able to localize low-frequency pure tones, indicating that they can use the binaural phase cue, but they were unable to localize pure tones above the frequency of phase ambiguity, thus indicating complete inability to use the binaural intensity-difference cue. In contrast, the alpacas relied on their high-frequency hearing for pinna cues; they could discriminate front-back sound sources using 3-kHz high-pass noise, but not 3-kHz low-pass noise. These results are compared to those of other hoofed mammals and to mammals more generally.
A 100-200 MHz ultrasound biomicroscope.
Knspik, D A; Starkoski, B; Pavlin, C J; Foster, F S
2000-01-01
The development of higher frequency ultrasound imaging systems affords a unique opportunity to visualize living tissue at the microscopic level. This work was undertaken to assess the potential of ultrasound imaging in vivo using the 100-200 MHz range. Spherically focused lithium niobate transducers were fabricated. The properties of a 200 MHz center frequency device are described in detail. This transducer showed good sensitivity with an insertion loss of 18 dB at 200 MHz. Resolution of 14 /spl mu/m in the lateral direction and 12 /spl mu/m in the axial direction was achieved with f/1.14 focusing. A linear mechanical scan system and a scan converter were used to generate B-scan images at a frame rate up to 12 frames per second. System performance in B-mode imaging is limited by frequency dependent attenuation in tissues. An alternative technique, zone-focus image collection, was investigated to extend depth of field. Images of coronary arteries, the eye, and skin are presented along with some preliminary correlations with histology. These results demonstrate the feasibility of ultrasound biomicroscopy In the 100-200 MHz range. Further development of ultrasound backscatter imaging at frequencies up to and above 200 MHz will contribute valuable information about tissue microstructure.
Honda, Hitoshi; Iwata, Kentaro
2016-08-01
Personal protective equipment (PPE) protects healthcare workers (HCWs) from infection by highly virulent pathogens via exposure to body fluids and respiratory droplets. Given the recent outbreaks of contagious infectious diseases worldwide, including Ebola virus and Middle Eastern respiratory syndrome, there is urgent need for further research to determine optimal PPE use in high-risk settings. This review intends to provide a general understanding of PPE and to provide guidelines for appropriate use based on current evidence. Although previous studies have focused on the efficacy of PPE in preventing transmission of pathogens, recent studies have examined the dangers to HCWs during removal of PPE when risk of contamination is highest. Access to adequate PPE supplies is crucial to preventing transmission of pathogens, especially in resource-limited settings. Adherence to appropriate PPE use is a challenge due to inadequate education on its usage, technical difficulties, and tolerability of PPE in the workplace. Future projects aim at ameliorating this situation, including redesigning PPE which is crucial to improving the safety of HCWs. PPE remains the most important strategy for protecting HCW from potentially fatal pathogens. Further research into optimal PPE design and use to improve the safety of HCWs is urgently needed.
NASA Astrophysics Data System (ADS)
Guan, Qingbao; Yuan, Li; Zhang, Yi; Gu, Aijuan; Liang, Guozheng
2018-05-01
Aligned carbon nanotube bundles (ACNTB) with multi-level hierarchical structures were tailored by reactive polymer vinyl-terminated polyphenylene ether (PPE) for the excellent integrated property of bismaleimide-triazine (BT) resin. The PPE-tailored ACNTB (ACNTB@PPE) has increased strength for the penetration of PPE into porous ACNTB strengthening the interaction between each CNT. The strong interaction at the interface of ACNTB@PPE and BT matrix can be created owing to the reaction of the vinyl group in PPE on the surface of ACNTB and maleimide group in BT. BT with 2% ACNTB@PPE composite shows the optimal flexural strength, fracture toughness and tensile strength, which are 88%, 115% and 77% higher than those of BT, respectively. The introduction of ACNTB@PPE slightly enhances the thermal property of BT. ACNTB@PPE can significantly improve the flame retardancy of BT composites. As compared to individual ACNTB, ACNTB@PPE effectively improves the integrated property of BT composites mainly due to the chemical interaction at the interface of ACNTB@PPE and BT matrix and the increased interaction between each CNT.
Chen, Jie; Lu, Kai-Zhi; Yi, Bin; Chen, Yan
2016-04-01
Following a chemical, biological, radiation, and nuclear incident, prompt cardiopulmonary resuscitation (CPR) procedure is essential for patients who suffer cardiac arrest. But CPR when wearing personal protection equipment (PPE) before decontamination becomes a challenge for healthcare workers (HCW). Although previous studies have assessed the impact of PPE on airway management, there is little research available regarding the quality of chest compression (CC) when wearing PPE.A present randomized cross-over simulation study was designed to evaluate the effect of PPE on CC performance using mannequins.The study was set in one university medical center in the China.Forty anesthesia residents participated in this randomized cross-over study.Each participant performed 2 min of CC on a manikin with and without PPE, respectively. Participants were randomized into 2 groups that either performed CC with PPE first, followed by a trial without PPE after a 180-min rest, or vice versa.CPR recording technology was used to objectively quantify the quality of CC. Additionally, participants' physiological parameters and subjective fatigue score values were recorded.With the use of PPE, a significant decrease of the percentage of effective compressions (41.3 ± 17.1% with PPE vs 67.5 ± 15.6% without PPE, P < 0.001) and the percentage of adequate compressions (67.7 ± 18.9% with PPE vs 80.7 ± 15.5% without PPE, P < 0.001) were observed. Furthermore, the increases in heart rate, mean arterial pressure, and subjective fatigue score values were more obvious with the use of PPE (all P < 0.01).We found significant deterioration of CC performance in HCW with the use of a level-C PPE, which may be a disadvantage for enhancing survival of cardiac arrest.
Singh, Lakhwinder Pal; Bhardwaj, Arvind; Deepak, K K; Bedi, Raman
2009-08-01
Occupational noise has been recognized as hazardous for the human beings. A high noise level in forging shops is considered to lower the labour productivity and cause illness however occupational noise is being accepted as an integral part of the job. The present study has been carried out in 5 small scale hand tool forging units (SSI) of different sizes in Northern India in Punjab. Noise levels at various sections were measured. OSHA norms for hearing conservation has been incorporated which includes an exchange rate of 5 dB (A), criterion level at 90 dB (A), criterion time of 8 h, threshold level=80 dB (A), upper limit=140 dB (A) and with F/S response rate. Equivalent sound pressure level (L(eq)) has been measured in various sections of these plants. Noise at various sections like hammer section, cutting presses, punching, grinding and barrelling process was found to be >90 dB (A), which is greater than OSHA norms. A cross-sectional study on the basis of questionnaire has been carried out. The results of which revealed that 68% of the workers are not wearing ear protective equipments out of these 50% were not provided with PPE by the company. About 95% of the workers were suffering speech interference though high noise annoyance was reported by only 20%. It has been established that the maximum noise exposure is being taken by the workers as they are working more than 8h a day for six days per week. More than 90% workers are working 12 to 24 h over time per week which lead to very high noise exposure i.e. 50 to 80% per week higher than exposure time/week in USA or European countries(15, 16)).
Budhathoki, Shyam Sundar; Singh, Suman Bahadur; Sagtani, Reshu Agrawal; Niraula, Surya Raj; Pokharel, Paras Kumar
2014-01-01
Objective The proper use of safety measures by welders is an important way of preventing and/or reducing a variety of health hazards that they are exposed to during welding. There is a lack of knowledge about hazards and personal protective equipments (PPEs) and the use of PPE among the welders in Nepal is limited. We designed a study to assess welders’ awareness of hazards and PPE, and the use of PPE among the welders of eastern Nepal and to find a possible correlation between awareness and use of PPE among them. Materials and methods A cross-sectional study of 300 welders selected by simple random sampling from three districts of eastern Nepal was conducted using a semistructured questionnaire. Data regarding age, education level, duration of employment, awareness of hazards, safety measures and the actual use of safety measures were recorded. Results Overall, 272 (90.7%) welders were aware of at least one hazard of welding and a similar proportion of welders were aware of at least one PPE. However, only 47.7% used one or more types of PPE. Education and duration of employment were significantly associated with the awareness of hazards and of PPE and its use. The welders who reported using PPE during welding were two times more likely to have been aware of hazards (OR=2.52, 95% CI 1.09 to 5.81) and five times more likely to have been aware of PPE compared with the welders who did not report the use of PPE (OR=5.13, 95% CI 2.34 to 11.26). Conclusions The welders using PPE were those who were aware of hazards and PPE. There is a gap between being aware of hazards and PPE (90%) and use of PPE (47%) at work. Further research is needed to identify the underlying factors leading to low utilisation of PPE despite the welders of eastern Nepal being knowledgeable of it. PMID:24889850
PPE Surface Proteins Are Required for Heme Utilization by Mycobacterium tuberculosis
Mitra, Avishek; Speer, Alexander; Lin, Kan; Ehrt, Sabine
2017-01-01
ABSTRACT Iron is essential for replication of Mycobacterium tuberculosis, but iron is efficiently sequestered in the human host during infection. Heme constitutes the largest iron reservoir in the human body and is utilized by many bacterial pathogens as an iron source. While heme acquisition is well studied in other bacterial pathogens, little is known in M. tuberculosis. To identify proteins involved in heme utilization by M. tuberculosis, a transposon mutant library was screened for resistance to the toxic heme analog gallium(III)-porphyrin (Ga-PIX). Inactivation of the ppe36, ppe62, and rv0265c genes resulted in resistance to Ga-PIX. Growth experiments using isogenic M. tuberculosis deletion mutants showed that PPE36 is essential for heme utilization by M. tuberculosis, while the functions of PPE62 and Rv0265c are partially redundant. None of the genes restored growth of the heterologous M. tuberculosis mutants, indicating that the proteins encoded by the genes have separate functions. PPE36, PPE62, and Rv0265c bind heme as shown by surface plasmon resonance spectroscopy and are associated with membranes. Both PPE36 and PPE62 proteins are cell surface accessible, while the Rv0265c protein is probably located in the periplasm. PPE36 and PPE62 are, to our knowledge, the first proline-proline-glutamate (PPE) proteins of M. tuberculosis that bind small molecules and are involved in nutrient acquisition. The absence of a virulence defect of the ppe36 deletion mutant indicates that the different iron acquisition pathways of M. tuberculosis may substitute for each other during growth and persistence in mice. The emerging model of heme utilization by M. tuberculosis as derived from this study is substantially different from those of other bacteria. PMID:28119467
PPE57 induces activation of macrophages and drives Th1-type immune responses through TLR2.
Xu, Ying; Yang, Enzhuo; Huang, Qi; Ni, Wenwen; Kong, Cong; Liu, Guoyuan; Li, Guanghua; Su, Haibo; Wang, Honghai
2015-06-01
Proline-glutamic acid (PE) and proline-proline-glutamic acid (PPE) are related proteins exclusive to Mycobacteria that play diverse roles in modulating critical innate immune pathways. In this study, we observed that the PPE57 protein is associated with the cell wall and is exposed on the cell surface. PPE57 enhances Mycobacterium spp. entering into macrophages and plays a role in macrophage phagocytosis. To explore the underlying mechanism, we demonstrated that PPE57 is able to recognise Toll-like receptor 2 (TLR2) and further induce macrophage activation by augmenting the expression of several cell surface molecules (CD40, CD80, CD86 and MHC class II) and pro-inflammatory cytokines (TNF-α, IL-6 and IL-12p40) within macrophages. These molecules are involved in the mitogen-activated protein kinase (MAPK) and nuclear factor κB (NF-κB) signalling pathways. We demonstrated that PPE57 effectively polarises T cells to secrete interferon (IFN)-γ and IL-2 and to up-regulate CXCR3 expression in vivo and in vitro, suggesting that this protein may contribute to Th1 polarisation during the immune response. Moreover, recombinant Bacillus Calmette-Guérin (BCG) over-expressing PPE57 could provide better protective efficacy against Mycobacterium tuberculosis challenge compared with BCG. Taken together, our data provides several pieces of evidence that PPE57 may regulate innate and adaptive immunity by interacting with TLR2. These findings indicate that PPE57 protein is a potential antigen for the rational design of an efficient vaccine against M. tuberculosis. PPE57 is located on the cell surface and enhances mycobacterium entry into macrophage. PPE57 interacts directly with TLR2 on macrophages. PPE57 plays a key role in the activation of macrophages in a TLR2-dependent manner. PPE57 induces a Th1 immune response via TLR2-mediated macrophage functions. Recombinant BCG over-expressing PPE57 could improve protective efficacy against M. tuberculosis.
First-year medical students' willingness to participate in peer physical examination.
Reid, Katharine J; Kgakololo, Meshak; Sutherland, Ruth M; Elliott, Susan L; Dodds, Agnes E
2012-01-01
There is little research on student attitudes toward participating in peer physical examination (PPE). This study explored first-year medical students' attitudes toward PPE and their willingness to participate in PPE before they had experience with PPE as part of their course. First-year medical students (n = 119) rated their willingness to participate in PPE for 15 body regions, with male or female peers, and when examining or being examined by others. Attitudes toward participating in PPE were also assessed. Low-sensitivity examinations (e.g., hands, head) in PPE were generally accepted by male and female students. Significant variation in willingness across different body regions was, however, evident for male and female students depending on the type of examination and their examination partner's gender. Students generally held positive attitudes toward participating in PPE as part of the course. Moreover, students with more positive attitudes provided higher ratings of willingness to participate in PPE for all examination types. Findings suggest high levels of willingness to participate in PPE for low-sensitivity examinations of the kind employed in university teaching contexts. Nonetheless, gender effects appear more complex than previously described, and for some regions of the body, there are subtle preferences for particular examination types, in particular performing examinations, rather than being examined.
Personal protective equipment for the Ebola virus disease: A comparison of 2 training programs.
Casalino, Enrique; Astocondor, Eugenio; Sanchez, Juan Carlos; Díaz-Santana, David Enrique; Del Aguila, Carlos; Carrillo, Juan Pablo
2015-12-01
Personal protective equipment (PPE) for preventing Ebola virus disease (EVD) includes basic PPE (B-PPE) and enhanced PPE (E-PPE). Our aim was to compare conventional training programs (CTPs) and reinforced training programs (RTPs) on the use of B-PPE and E-PPE. Four groups were created, designated CTP-B, CTP-E, RTP-B, and RTP-E. All groups received the same theoretical training, followed by 3 practical training sessions. A total of 120 students were included (30 per group). In all 4 groups, the frequency and number of total errors and critical errors decreased significantly over the course of the training sessions (P < .01). The RTP was associated with a greater reduction in the number of total errors and critical errors (P < .0001). During the third training session, we noted an error frequency of 7%-43%, a critical error frequency of 3%-40%, 0.3-1.5 total errors, and 0.1-0.8 critical errors per student. The B-PPE groups had the fewest errors and critical errors (P < .0001). Our results indicate that both training methods improved the student's proficiency, that B-PPE appears to be easier to use than E-PPE, that the RTP achieved better proficiency for both PPE types, and that a number of students are still potentially at risk for EVD contamination despite the improvements observed during the training. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Garcia-Molina, Antoni; Xing, Shuping; Huijser, Peter
2014-08-30
The Arabidopsis SQUAMOSA PROMOTER-BINDING PROTEIN-LIKE (SPL) transcription factor SPL7 reprograms cellular gene expression to adapt plant growth and cellular metabolism to copper (Cu) limited culture conditions. Plant cells require Cu to maintain essential processes, such as photosynthesis, scavenging reactive oxygen species, cell wall lignification and hormone sensing. More specifically, SPL7 activity promotes a high-affinity Cu-uptake system and optimizes Cu (re-)distribution to essential Cu-proteins by means of specific miRNAs targeting mRNA transcripts for those dispensable. However, the functional mechanism underlying SPL7 activation is still to be elucidated. As SPL7 transcript levels are largely non-responsive to Cu availability, post-translational modification seems an obvious possibility. Previously, it was reported that the SPL7 SBP domain does not bind to DNA in vitro in the presence of Cu ions and that SPL7 interacts with a kin17 domain protein to raise SPL7-target gene expression upon Cu deprivation. Here we report how additional conserved SPL7 protein domains may contribute to the Cu deficiency response in Arabidopsis. Cytological and biochemical approaches confirmed an operative transmembrane domain (TMD) and uncovered a dual localisation of SPL7 between the nucleus and an endomembrane system, most likely the endoplasmic reticulum (ER). This new perspective unveiled a possible link between Cu deficit and ER stress, a metabolic dysfunction found capable of inducing SPL7 targets in an SPL7-dependent manner. Moreover, in vivo protein-protein interaction assays revealed that SPL7 is able to homodimerize, probably mediated by the IRPGC domain. These observations, in combination with the constitutive activation of SPL7 targets, when ectopically expressing the N-terminal part of SPL7 including the SBP domain, shed some light on the mechanisms governing SPL7 function. Here, we propose a revised model of SPL7 activation and regulation. According to our results, SPL7 would be initially located to endomembranes and activated during ER stress as a result of Cu deficiency. Furthermore, we added the SPL7 dimerization in the presence of Cu ions as an additional regulatory mechanism to modulate the Cu deficiency response.
Ear-Canal Reflectance, Umbo Velocity and Tympanometry in Normal Hearing Adults
Rosowski, John J; Nakajima, Hideko H.; Hamade, Mohamad A.; Mafoud, Lorice; Merchant, Gabrielle R.; Halpin, Christopher F.; Merchant, Saumil N.
2011-01-01
Objective This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle-ear function including, audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal hearing ears. Design Data were prospectively gathered from 58 ears of 29 normal hearing subjects, 16 female and 13 male, aged 22–64 years. Subjects met all of the following criteria to be considered as having normal hearing. (1) No history of significant middle-ear disease. (2) No history of otologic surgery. (3) Normal tympanic membrane (TM) on otoscopy. (4) Pure-tone audiometric thresholds of 20 dB HL or better for 0.25 – 8 kHz. (5) Air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 – 4 kHz. (6) Normal, type-A peaked tympanograms. (7) All subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 – 8 kHz, standard 226 Hz tympanometry, Ear canal reflectance(ECR) for 0.2 – 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and Umbo Velocity (VU ) for 0.3 – 6 kHz at 70–90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results Mean power reflectance (|ECR|2) was near 1.0 at 0.2– 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 ms for 0.2 – 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears, and between males and females at 4 kHz. |ECR|2 decreased with age, but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR|2 and The results suggest that middle-ear compliance VU at frequencies below 1 kHz. contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz, but not at higher frequencies. Conclusions This study has established a database of objective measurements of middle ear function (ear-canal reflectance, umbo velocity, tympanometry) in a population of strictly defined normal hearing ears. The data will promote our understanding of normal middle ear function, and will serve as a control for comparison to similar measurements made in pathological ears. PMID:21857517
Rajabi, M; Rouzbehan, Y; Rezaei, J
2017-01-01
Dietary natural plant secondary metabolites (PSM) extracted from a pomegranate peel (PP) byproduct have the potential to improve milk yield and the milk fatty acid profile of dairy cows. This experiment was performed to assess the influence of different dietary levels of PP extract (PPE) on feedlot performance, ruminal status, nutrient utilization, and antioxidant status in fattening Moghani lambs. Thirty-two lambs (initial BW of 22 ± 1.2 kg) were used in a completely randomized design with a 72-d period and 4 treatments: PPE0 (no extract), PPE15 (15 mL PPE/kg of diet DM), PPE30 (30 mL PPE/kg of diet DM), and PPE45 (45 mL PPE/kg of diet DM). Feed intake, lamb growth, diet digestibility, microbial nitrogen (N) synthesis (MNS), N retention, rumen parameters, and blood metabolites were determined. The addition of PPE to the diet of lambs had no effect on DMI (linear [L], = 0.96; quadratic [Q], = 0.65). In vivo digestibility coefficients of DM, OM, CP, and Ash-free NDF were not affected (L, ≥ 0.28; Q, ≥ 0.26) by different levels of PPE, but it increased ADG (L, = 0.045; Q, = 0.19) and G:F (L, = 0.046; Q, = 0.20). Rumen pH, VFA concentrations, and acetate-to-propionate ratio were not affected (L, ≥ 0.14; Q, ≥ 0.23) by PPE supplementation. Dietary inclusion of PPE decreased the ruminal concentration of ammonia N (L, = 0.014; Q, = 0.67), total protozoa enumeration (L, < 0.001; Q, = 0.043), population (L, < 0.001; Q, = 0.19), urinary N excretion (L, = 0.005; Q, = 0.26), whereas MNS (L, = 0.019; Q, = 0.23) and N retention (L, < 0.001; Q, = 0.66) increased. Feeding PPE had no effect (L, ≥ 0.11; Q, ≥ 0.17) on plasma concentrations of glucose, triglycerides, cholesterol, total protein, albumin, or albumin-to-globulin ratio. Blood urea N (L, = 0.021; Q, = 0.32) decreased with dietary addition of PPE, while total antioxidant capacity (TAC) in the rumen fluid (L, = 0.032; Q, = 0.64) and TAC in the blood (L, = 0.041; Q, = 0.51) increased. Overall, dietary inclusion of PPE, up to 45 mL/kg of diet DM, linearly improved animal growth, N retention, and antioxidant capacities of the blood and rumen fluid. The PPE is a safe natural additive for use in sheep diets that can help to reduce environmental pollution by reducing urinary N excretion.
Does medical student willingness to practise peer physical examination translate into action?
Chen, Julie Y; Yip, Amber L M; Lam, Cindy L K; Patil, Nivritti G
2011-01-01
Peer physical examination (PPE) is commonly used in clinical skills teaching to allow students to practice physical examination techniques on each other. Previous studies have demonstrated medical students' generally positive attitudes towards PPE, but the correlation between student attitude and actual practice of PPE has yet to be examined. To determine if a positive student attitude towards PPE leads to subsequent action. The target population were MBBS I students (2006-2007 cohort) admitted to the Li Ka Shing Faculty of Medicine, The University of Hong Kong. Student attitude towards PPE and subsequent practice of PPE were assessed through self-completed written questionnaires before and after the compulsory Clinical Skills Programme (CSP). A total of 100/128 (78%) students completed both questionnaires, of which 83 (65%) could be linked to demographic data. All study participants were ethnically Chinese. A high level of willingness to conduct PPE persisted before and after the CSP for both male and female students. However, more than half of the students did not subsequently examine various non-intimate body regions of a fellow student during the CSP. Female students were more likely to exhibit attitude-behaviour inconsistency. The existing positive attitudes towards PPE need to be harnessed so that more students are encouraged to follow through and actually practise PPE, thus realizing the educational benefits of this activity. This may be done by ensuring that PPE is conducted in a safe setting while being conscientious of gender differences. Scheduled time and the use of a logbook may be useful to facilitate students practising PPE.
Sayes, Fadel; Pawlik, Alexandre; Frigui, Wafa; Gröschel, Matthias I.; Crommelynck, Samuel; Fayolle, Catherine; Cia, Felipe; Bancroft, Gregory J.; Bottai, Daria; Leclerc, Claude; Brosch, Roland; Majlessi, Laleh
2016-01-01
Mycobacterium tuberculosis (Mtb), possesses at least three type VII secretion systems, ESX-1, -3 and -5 that are actively involved in pathogenesis and host-pathogen interaction. We recently showed that an attenuated Mtb vaccine candidate (Mtb Δppe25-pe19), which lacks the characteristic ESX-5-associated pe/ppe genes, but harbors all other components of the ESX-5 system, induces CD4+ T-cell immune responses against non-esx-5-associated PE/PPE protein homologs. These T cells strongly cross-recognize the missing esx-5-associated PE/PPE proteins. Here, we characterized the fine composition of the functional cross-reactive Th1 effector subsets specific to the shared PE/PPE epitopes in mice immunized with the Mtb Δppe25-pe19 vaccine candidate. We provide evidence that the Mtb Δppe25-pe19 strain, despite its significant attenuation, is comparable to the WT Mtb strain with regard to: (i) its antigenic repertoire related to the different ESX systems, (ii) the induced Th1 effector subset composition, (iii) the differentiation status of the Th1 cells induced, and (iv) its particular features at stimulating the innate immune response. Indeed, we found significant contribution of PE/PPE-specific Th1 effector cells in the protective immunity against pulmonary Mtb infection. These results offer detailed insights into the immune mechanisms underlying the remarkable protective efficacy of the live attenuated Mtb Δppe25-pe19 vaccine candidate, as well as the specific potential of PE/PPE proteins as protective immunogens. PMID:27467705
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... Standard on Personal Protective Equipment (PPE) for Shipyard Employment; Extension of the Office of... requirements specified in the Standard on Personal Protective Equipment (PPE) for Shipyard Employment (29 CFR... information collection requirements contained in the Standard on Personal Protective Equipment (PPE) for...
Doksæter, Lise; Handegard, Nils Olav; Godø, Olav Rune; Kvadsheim, Petter H; Nordlund, Nina
2012-02-01
Atlantic herring, Clupea harengus, is a hearing specialist, and several studies have demonstrated strong responses to man-made noise, for example, from an approaching vessel. To avoid negative impacts from naval sonar operations, a set of studies of reaction patters of herring to low-frequency (1.0-1.5 kHz) naval sonar signals has been undertaken. This paper presents herring reactions to sonar signals and other stimuli when kept in captivity under detailed acoustic and video monitoring. Throughout the experiment, spanning three seasons of a year, the fish did not react significantly to sonar signals from a passing frigate, at received root-mean-square sound-pressure level (SPL) up to 168 dB re 1 μPa. In contrast, the fish did exhibit a significant diving reaction when exposed to other sounds, with a much lower SPL, e.g., from a two-stroke engine. This shows that the experimental setup is sensitive to herring reactions when occurring. The lack of herring reaction to sonar signals is consistent with earlier in situ behavioral studies. The complexity of the behavioral reactions in captivity underline the need for better understanding of the causal relationship between stimuli and reaction patterns of fish. © 2012 Acoustical Society of America
Design and analysis of a hemi-anechoic chamber at Michigan Technological University
NASA Astrophysics Data System (ADS)
Dreyer, Jason; Jangale, Ashish; Rao, Mohan D.
2005-09-01
A four-wheel chassis roll dynamometer test facility was installed on the campus of Michigan Technological University (MTU). The chassis dynamometer was enclosed in a soundproof hem-anechoic room in order to conduct noise radiation measurements on test vehicles. All surfaces of the room, except the floor and control room window, were acoustically treated with donated tetrahedral acoustic cones and panels. The acoustic absorption properties of these materials were characterized through reverberation chamber and impedance tube testing, and the effects of air gaps, cone orientation, and cone mounting materials were qualitatively evaluated. The design of the wall, ceiling, and door treatments of the chamber was based on the sound absorption properties of these materials, in addition to spatial constraints and cost considerations. The treated chamber acoustics were predicted based on the amount of acoustic material that could be applied to given chamber dimensions and would still preserve the functionality of the room. These predictions were validated through evaluation of the actual room treatment based on average reverberation time at 100-Hz third-octave band, free sound field characteristic 6-dB reduction in sound pressure level (SPL) per doubling in distance from source, noise reduction at the chamber boundaries, and background SPL Noise Criteria (NC) Rating.
Atmospheric effects on voice command intelligibility from acoustic hail and warning devices.
Bostron, Jason H; Brungart, Timothy A; Barnard, Andrew R; McDevitt, Timothy E
2011-04-01
Voice command sound pressure levels (SPLs) were recorded at distances up to 1500 m. Received SPLs were related to the meteorological condition during sound propagation and compared with the outdoor sound propagation standard ISO 9613-2. Intelligibility of received signals was calculated using ANSI S3.5. Intelligibility results for the present voice command indicate that meteorological condition imposes little to no effect on intelligibility when the signal-to-noise ratio (SNR) is low (<-9 dB) or high (>0 dB). In these two cases the signal is firmly unintelligible or intelligible, respectively. However, at moderate SNRs, variations in received SPL can cause a fully intelligible voice command to become unintelligible, depending on the meteorological condition along the sound propagation path. These changes in voice command intelligibility often occur on time scales as short as minutes during upward refracting conditions, typically found above ground during the day or upwind of a sound source. Reliably predicting the intelligibility of a voice command in a moderate SNR environment can be challenging due to the inherent variability imposed by sound propagation through the atmosphere.
SPL13 regulates shoot branching and flowering time in Medicago sativa.
Gao, Ruimin; Gruber, Margaret Y; Amyot, Lisa; Hannoufa, Abdelali
2018-01-01
Our results show SPL13 plays a crucial role in regulating vegetative and reproductive development in Medicago sativa L. (alfalfa), and that MYB112 is targeted and downregulated by SPL13 in alfalfa. We previously showed that transgenic Medicago sativa (alfalfa) plants overexpressing microRNA156 (miR156) show a bushy phenotype, reduced internodal length, delayed flowering time, and enhanced biomass yield. In alfalfa, transcripts of seven SQUAMOSA-PROMOTER BINDING PROTEIN-LIKE (SPL) transcription factors, including SPL13, are targeted for cleavage by miR156. Thus, association of each target SPL gene to a trait or set of traits is essential for developing molecular markers for alfalfa breeding. In this study, we investigated SPL13 function using SPL13 overexpression and silenced alfalfa plants. Severe growth retardation, distorted branches and up-curled leaves were observed in miR156-impervious 35S::SPL13m over-expression plants. In contrast, more lateral branches and delayed flowering time were observed in SPL13 silenced plants. SPL13 transcripts were predominantly present in the plant meristems, indicating that SPL13 is involved in regulating shoot branch development. Accordingly, the shoot branching-related CAROTENOID CLEAVAGE DIOXYGENASE 8 gene was found to be significantly downregulated in SPL13 RNAi silencing plants. A R2R3-MYB gene MYB112 was also identified as being directly silenced by SPL13 based on Next Generation Sequencing-mediated transcriptome analysis and chromatin immunoprecipitation assays, suggesting that MYB112 may be involved in regulating alfalfa vegetative growth.
Susceptibility to acoustic trauma in young and aged gerbils
NASA Astrophysics Data System (ADS)
Boettcher, Flint A.
2002-12-01
The effect of age on susceptibility to noise-induced hearing loss (NIHL), the effect of gender on the interaction of age-related hearing loss (ARHL) and NIHL, and the relative contributions of ARHL and NIHL to total hearing loss are poorly understood. The issues are difficult to resolve empirically in human subjects because of lack of control over extrinsic variables and for ethical reasons. Accordingly, these issues were examined in a well-studied animal model of both ARHL and NIHL, the Mongolian gerbil. Animals were exposed to an intense tone (3.5 kHz, 113 dB SPL, 1 h) either as young adults (6-8 months) or near the end of the average lifespan of the species (34-38 months). Hearing thresholds were determined with the auditory brainstem response (ABR). ARHL was approximately 5-10 dB, with slightly more observed in males at 16 kHz (p<0.05). NIHL of approximately 15-20 dB was similar for the young and old groups, suggesting no differences in susceptibility as a function of age. There were no gender differences in NIHL. The relative contributions of ARHL and NIHL to total hearing loss in aged, noise-exposed gerbils were predicted by an addition of ARHL and NIHL in dB, similar to an international standard on hearing loss allocation, ISO-1999 [Determination of Occupational Noise Exposure and Estimation of Noise-Induced Hearing Impairment (1990)]. Previous evaluations of ISO-1999 using the gerbil animal model concluded that addition of ARHL and NIHL in dB overpredicts total hearing loss. However, in these studies, ARHL was large and nearly equal to NIHL. In the current study, where ARHL was much less than NIHL, addition of the two factors in dB, as recommended by ISO-1999, results in fairly accurate predictions of total hearing loss.
NASA Rat Acoustic Tolerance Test 1994-1995: 8 kHz, 16 kHz, 32 kHz Experiments
NASA Technical Reports Server (NTRS)
Mele, Gary D.; Holley, Daniel C.; Naidu, Sujata
1996-01-01
Adult male Sprague-Dawley rats were exposed to chronic applied sound (74 to 79 dB, SPL) with octave band center frequencies of either 8, 16 or 32 kHz for up to 60 days. Control cages had ambient sound levels of about 62 dB (SPL). Groups of rats (test vs. control; N=9 per group) were euthanized after 0. 5. 14, 30, and 60 days. On each euthanasia day, objective evaluation of their physiology and behavior was performed using a Stress Assessment Battery (SAB) of measures. In addition, rat hearing was assessed using the brain stem auditory evoked potential (BAER) method after 60 days of exposure. No statistically significant differences in mean daily food use could be attributed to the presence of the applied test sound. Test rats used 5% more water than control rats. In the 8 kHz and 32 kHz tests this amount was statistically significant(P less than .05). This is a minor difference of questionable physiological significance. However, it may be an indication of a small reaction to the constant applied sound. Across all test frequencies, day 5 test rats had 6% larger spleens than control rats. No other body or organ weight differences were found to be statistically significant with respect to the application of sound. This spleen effect may be a transient adaptive process related to adaptation to the constant applied noise. No significant test effect on differential white blood cell counts could be demonstrated. One group demonstrated a low eosinophil count (16 kHz experiment, day 14 test group). However this was highly suspect. Across all test frequencies studied, day 5 test rats had 17% fewer total leukocytes than day 5 control rats. Sound exposed test rats exhibited 44% lower plasma corticosterone concentrations than did control rats. Note that the plasma corticosterone concentration was lower in the sound exposed test animals than the control animals in every instance (frequency exposure and number of days exposed).
Danielsson, Henrik; Hällgren, Mathias; Stenfelt, Stefan; Rönnberg, Jerker; Lunner, Thomas
2016-01-01
The audiogram predicts <30% of the variance in speech-reception thresholds (SRTs) for hearing-impaired (HI) listeners fitted with individualized frequency-dependent gain. The remaining variance could reflect suprathreshold distortion in the auditory pathways or nonauditory factors such as cognitive processing. The relationship between a measure of suprathreshold auditory function—spectrotemporal modulation (STM) sensitivity—and SRTs in noise was examined for 154 HI listeners fitted with individualized frequency-specific gain. SRTs were measured for 65-dB SPL sentences presented in speech-weighted noise or four-talker babble to an individually programmed master hearing aid, with the output of an ear-simulating coupler played through insert earphones. Modulation-depth detection thresholds were measured over headphones for STM (2cycles/octave density, 4-Hz rate) applied to an 85-dB SPL, 2-kHz lowpass-filtered pink-noise carrier. SRTs were correlated with both the high-frequency (2–6 kHz) pure-tone average (HFA; R2 = .31) and STM sensitivity (R2 = .28). Combined with the HFA, STM sensitivity significantly improved the SRT prediction (ΔR2 = .13; total R2 = .44). The remaining unaccounted variance might be attributable to variability in cognitive function and other dimensions of suprathreshold distortion. STM sensitivity was most critical in predicting SRTs for listeners < 65 years old or with HFA <53 dB HL. Results are discussed in the context of previous work suggesting that STM sensitivity for low rates and low-frequency carriers is impaired by a reduced ability to use temporal fine-structure information to detect dynamic spectra. STM detection is a fast test of suprathreshold auditory function for frequencies <2 kHz that complements the HFA to predict variability in hearing-aid outcomes for speech perception in noise. PMID:27815546
Influence of cochlear traveling wave and neural adaptation on auditory brainstem responses.
Junius, Dirk; Dau, Torsten
2005-07-01
The present study investigates the relationship between evoked responses to transient broadband chirps and responses to the same chirps when embedded in longer-duration stimuli. It examines to what extent the responses to the composite stimuli can be explained by a linear superposition of the responses to the single components, as a function of stimulus level. In the first experiment, a single rising chirp was temporally and spectrally embedded in two steady-state tones. In the second experiment, the stimulus consisted of a continuous alternating train of chirps: each rising chirp was followed by the temporally reversed (falling) chirp. In both experiments, the transitions between stimulus components were continuous. For stimulation levels up to approximately 70 dB SPL, the responses to the embedded chirp corresponded to the responses to the single chirp. At high stimulus levels (80-100 dB SPL), disparities occurred between the responses, reflecting a nonlinearity in the processing when neural activity is integrated across frequency. In the third experiment, the effect of within-train rate on wave-V response was investigated. The response to the chirp presented at a within-train rate of 95 Hz exhibited the same amplitude as that to the chirp presented in the traditional single-stimulus paradigm at a rate of 13 Hz. For a corresponding experiment with bandlimited chirps of 4 ms duration, where the within-train rate was 250 Hz, a clear reduction of the response amplitude was observed. This nonlinearity in terms of temporal processing most likely reflects effects of short-term adaptation. Overall, the results of the present study further demonstrate the importance of cochlear processing for the formation of brainstem potentials. The data may provide constraints on future models of peripheral processing in the human auditory system. The findings might also be useful for the development of effective stimulation paradigms in clinical applications.
An Assessment of the Theoretical Underpinnings of Practical Participatory Evaluation
ERIC Educational Resources Information Center
Smits, Pernelle A.; Champagne, Francois
2008-01-01
This article is concerned with the underpinnings of practical participatory evaluation (PPE). Evaluation approaches have long been criticized because their results are often not used. It is believed that PPE addresses this drawback. The article focuses on the mechanisms underlying the links between activities and consequences in PPE. A PPE theory…
Rubenstein, Eric; Shendell, Derek; Eggert, Brain C; Marcella, Stephen W
2014-01-01
Students with special health care needs (SHCNs) and individualized education plans (IEPs) may be injured more often in vocational, career, and technical education (CTE) programs. No research to date considers personal protective equipment (PPE) use among students with SHCNs in school-based programs reporting injuries to agencies. Data from 1999 to 2011 on PPE use among injured students in CTE programs in public schools and private secondary schools for the disabled were analyzed; students with SHCNs were distinguished by IEP status within New Jersey Safe Schools surveilance data. Among students with IEPs using PPE, 36% of injuries occurred to body parts PPE was meant to protect. Likely injury types were cuts-lacerations and burns for students with IEPs using PPE and cuts-lacerations and sprains for students with IEPs not using PPE. Females with IEPs using PPE were injured less often than males across ages. Results suggested students with SHCNs with IEPs need further job-related training with increased emphasis on properly selecting and fitting PPE.
Aoun, Manar; Michel, Francoise; Fouret, Gilles; Schlernitzauer, Audrey; Ollendorff, Vincent; Wrutniak-Cabello, Chantal; Cristol, Jean-Paul; Carbonneau, Marie-Annette; Coudray, Charles; Feillet-Coudray, Christine
2011-08-01
Accumulation of muscle TAG content and modification of muscle phospholipid fatty acid pattern may have an impact on lipid metabolism, increasing the risk of developing diabetes. Some polyphenols have been reported to modulate lipid metabolism, in particular those issued from red grapes. The present study was designed to determine whether a grape polyphenol extract (PPE) modulates skeletal muscle TAG content and phospholipid fatty acid composition in high-fat-high-sucrose (HFHS) diet-fed rats. Muscle plasmalemmal and mitochondrial fatty acid transporters, GLUT4 and lipid metabolism pathways were also explored. The PPE decreased muscle TAG content in HFHS/PPE diet-fed rats compared with HFHS diet-fed rats and induced higher proportions of n-3 PUFA in phospholipids. The PPE significantly up-regulated GLUT4 mRNA expression. Gene and protein expression of muscle fatty acid transporter cluster of differentiation 36 (CD36) was increased in HFHS diet-fed rats but returned to control values in HFHS/PPE diet-fed rats. Carnitine palmitoyltransferase 1 protein expression was decreased with the PPE. Mitochondrial β-hydroxyacyl CoA dehydrogenase was increased in HFHS diet-fed rats and returned to control values with PPE supplementation. Lipogenesis, mitochondrial biogenesis and mitochondrial activity were not affected by the PPE. In conclusion, the PPE modulated membrane phospholipid fatty acid composition and decreased muscle TAG content in HFHS diet-fed rats. The PPE lowered CD36 gene and protein expression, probably decreasing fatty acid transport and lipid accumulation within skeletal muscle, and increased muscle GLUT4 expression. These effects of the PPE are in favour of a better insulin sensibility.
Pan, Feng; Wang, Yue; Liu, Huanglong; Wu, Min; Chu, Wenyuan; Chen, Danmei; Xiang, Yan
2017-06-27
The SQUAMOSA promoter binding protein-like (SPL) proteins are plant-specific transcription factors (TFs) that function in a variety of developmental processes including growth, flower development, and signal transduction. SPL proteins are encoded by a gene family, and these genes have been characterized in two model grass species, Zea mays and Oryza sativa. The SPL gene family has not been well studied in moso bamboo (Phyllostachys edulis), a woody grass species. We identified 32 putative PeSPL genes in the P. edulis genome. Phylogenetic analysis arranged the PeSPL protein sequences in eight groups. Similarly, phylogenetic analysis of the SBP-like and SBP proteins from rice and maize clustered them into eight groups analogous to those from P. edulis. Furthermore, the deduced PeSPL proteins in each group contained very similar conserved sequence motifs. Our analyses indicate that the PeSPL genes experienced a large-scale duplication event ~15 million years ago (MYA), and that divergence between the PeSPL and OsSPL genes occurred 34 MYA. The stress-response expression profiles and tissue-specificity of the putative PeSPL gene promoter regions showed that SPL genes in moso bamboo have potential biological functions in stress resistance as well as in growth and development. We therefore examined PeSPL gene expression in response to different plant hormone and drought (polyethylene glycol-6000; PEG) treatments to mimic biotic and abiotic stresses. Expression of three (PeSPL10, -12, -17), six (PeSPL1, -10, -12, -17, -20, -31), and nine (PeSPL5, -8, -9, -14, -15, -19, -20, -31, -32) genes remained relatively stable after treating with salicylic acid (SA), gibberellic acid (GA), and PEG, respectively, while the expression patterns of other genes changed. In addition, analysis of tissue-specific expression of the moso bamboo SPL genes during development showed differences in their spatiotemporal expression patterns, and many were expressed at high levels in flowers and leaves. The PeSPL genes play important roles in plant growth and development, including responses to stresses, and most of the genes are expressed in different tissues. Our study provides a comprehensive understanding of the PeSPL gene family and may enable future studies on the function and evolution of SPL genes in moso bamboo.
Easwar, Vijayalakshmi; Purcell, David W; Aiken, Steven J; Parsa, Vijay; Scollie, Susan D
2015-01-01
The use of auditory evoked potentials as an objective outcome measure in infants fitted with hearing aids has gained interest in recent years. This article proposes a test paradigm using speech-evoked envelope following responses (EFRs) for use as an objective-aided outcome measure. The method uses a running speech-like, naturally spoken stimulus token /susa∫i/ (fundamental frequency [f0] = 98 Hz; duration 2.05 sec), to elicit EFRs by eight carriers representing low, mid, and high frequencies. Each vowel elicited two EFRs simultaneously, one from the region of formant one (F1) and one from the higher formants region (F2+). The simultaneous recording of two EFRs was enabled by lowering f0 in the region of F1 alone. Fricatives were amplitude modulated to enable recording of EFRs from high-frequency spectral regions. The present study aimed to evaluate the effect of level and bandwidth on speech-evoked EFRs in adults with normal hearing. As well, the study aimed to test convergent validity of the EFR paradigm by comparing it with changes in behavioral tasks due to bandwidth. Single-channel electroencephalogram was recorded from the vertex to the nape of the neck over 300 sweeps in two polarities from 20 young adults with normal hearing. To evaluate the effects of level in experiment I, EFRs were recorded at test levels of 50 and 65 dB SPL. To evaluate the effects of bandwidth in experiment II, EFRs were elicited by /susa∫i/ low-pass filtered at 1, 2, and 4 kHz, presented at 65 dB SPL. The 65 dB SPL condition from experiment I represented the full bandwidth condition. EFRs were averaged across the two polarities and estimated using a Fourier analyzer. An F test was used to determine whether an EFR was detected. Speech discrimination using the University of Western Ontario Distinctive Feature Differences test and sound quality rating using the Multiple Stimulus Hidden Reference and Anchors paradigm were measured in identical bandwidth conditions. In experiment I, the increase in level resulted in a significant increase in response amplitudes for all eight carriers (mean increase of 14 to 50 nV) and the number of detections (mean increase of 1.4 detections). In experiment II, an increase in bandwidth resulted in a significant increase in the number of EFRs detected until the low-pass filtered 4 kHz condition and carrier-specific changes in response amplitude until the full bandwidth condition. Scores in both behavioral tasks increased with bandwidth up to the full bandwidth condition. The number of detections and composite amplitude (sum of all eight EFR amplitudes) significantly correlated with changes in behavioral test scores. Results suggest that the EFR paradigm is sensitive to changes in level and audible bandwidth. This may be a useful tool as an objective-aided outcome measure considering its running speech-like stimulus, representation of spectral regions important for speech understanding, level and bandwidth sensitivity, and clinically feasible test times. This paradigm requires further validation in individuals with hearing loss, with and without hearing aids.
Exploring medical students' attitudes towards peer physical examination.
Rees, Charlotte E; Bradley, Paul; McLachlan, John C
2004-02-01
With opportunities for dissection and examination of sick patients decreasing, the role of peer physical examination (PPE) is increasing. This study explores students' attitudes towards PPE and the relationship between attitudes and demographics. A total of 129 first-year medical students from the Peninsula Medical School completed the Examining Fellow Students (EFS) questionnaire. At least 97% of students were comfortable participating in PPE of all body parts except breast and inguinal regions. Over 20% of students were unwilling to participate in PPE of the breast and inguinal regions. Students were more comfortable with PPE within gender than across gender. Females were more likely to be uncomfortable with PPE. Further research with larger sample sizes is required to determine whether attitudes are related to age and religious faith.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekiert, Damian C.; Cox, Jeffery S.
Nearly 10% of the coding capacity of the Mycobacterium tuberculosis genome is devoted to two highly expanded and enigmatic protein families called PE and PPE, some of which are important virulence/immunogenicity factors and are secreted during infection via a unique alternative secretory system termed "type VII." How PE-PPE proteins function during infection and how they are translocated to the bacterial surface through the five distinct type VII secretion systems [ESAT-6 secretion system (ESX)] of M. tuberculosis is poorly understood. Here in this paper, we report the crystal structure of a PE-PPE heterodimer bound to ESX secretion-associated protein G (EspG), whichmore » adopts a novel fold. This PE-PPE-EspG complex, along with structures of two additional EspGs, suggests that EspG acts as an adaptor that recognizes specific PE-PPE protein complexes via extensive interactions with PPE domains, and delivers them to ESX machinery for secretion. Surprisingly, secretion of most PE-PPE proteins in M. tuberculosis is likely mediated by EspG from the ESX-5 system, underscoring the importance of ESX-5 in mycobacterial pathogenesis. Furthermore, our results indicate that PE-PPE domains function as cis-acting targeting sequences that are read out by EspGs, revealing the molecular specificity for secretion through distinct ESX pathways.« less
Ekiert, Damian C.; Cox, Jeffery S.
2014-10-01
Nearly 10% of the coding capacity of the Mycobacterium tuberculosis genome is devoted to two highly expanded and enigmatic protein families called PE and PPE, some of which are important virulence/immunogenicity factors and are secreted during infection via a unique alternative secretory system termed "type VII." How PE-PPE proteins function during infection and how they are translocated to the bacterial surface through the five distinct type VII secretion systems [ESAT-6 secretion system (ESX)] of M. tuberculosis is poorly understood. Here in this paper, we report the crystal structure of a PE-PPE heterodimer bound to ESX secretion-associated protein G (EspG), whichmore » adopts a novel fold. This PE-PPE-EspG complex, along with structures of two additional EspGs, suggests that EspG acts as an adaptor that recognizes specific PE-PPE protein complexes via extensive interactions with PPE domains, and delivers them to ESX machinery for secretion. Surprisingly, secretion of most PE-PPE proteins in M. tuberculosis is likely mediated by EspG from the ESX-5 system, underscoring the importance of ESX-5 in mycobacterial pathogenesis. Furthermore, our results indicate that PE-PPE domains function as cis-acting targeting sequences that are read out by EspGs, revealing the molecular specificity for secretion through distinct ESX pathways.« less
Diaphragm based long cavity Fabry-Perot fiber acoustic sensor using phase generated carrier
NASA Astrophysics Data System (ADS)
Liu, Bin; Lin, Jie; Liu, Huan; Ma, Yuan; Yan, Lei; Jin, Peng
2017-01-01
A diaphragm based long cavity Fabry-Perot interferometric fiber acoustic sensor is proposed. The Fabry-Perot cavity is formed by a flat fiber facet and an ultra-thin silver diaphragm with a 6-meter long fiber inserted in the cavity. A narrow-linewidth ring-cavity erbium-doped fiber laser is applied to demodulate the sensing signal in the phase generated carrier algorithm. Experimental results have demonstrated that the phase sensitivity is about -140 dB re 1 rad/μPa at 2 kHz. The noise equivalent acoustic signal level is 60.6 μPa/Hz1/2 and the dynamic range is 65.1 dB-SPL at 2 kHz. The sensor is suitable for sensing of weak acoustic signals.
Noise stimulation decreases the concentration of norepinephrine in the rat cochlea.
Vicente-Torres, M A; Gil-Loyzaga, P
1999-05-14
The present study was designed to analyze, by using high performance liquid chromatography (HPLC), the effect of acoustic stimulation on the cochlear concentration of norepinephrine (NE). Independently of the rat strain (Long-Evans or Wistar strains), NE concentration decreased about 18% when animals were exposed to white noise (90 dB SPL for 1 h). The same decrease was observed in animals perfused by aortic pathway to remove the blood, indicating that this decrease corresponds exclusively to a neurophysiological process. In fact, these findings could indicate that noise stimulation is involved in the NE release from sympathetic fibers innervating the cochlea. This likely release of NE supports that sympathetic fibers play a functional role in cochleae exposed to noisy situations.
Arabidopsis mutant sk156 reveals complex regulation of SPL15 in a miR156-controlled gene network.
Wei, Shu; Gruber, Margaret Y; Yu, Bianyun; Gao, Ming-Jun; Khachatourians, George G; Hegedus, Dwayne D; Parkin, Isobel A P; Hannoufa, Abdelali
2012-09-18
The Arabidopsis microRNA156 (miR156) regulates 11 members of the SQUAMOSA PROMOTER BINDING PROTEIN LIKE (SPL) family by base pairing to complementary target mRNAs. Each SPL gene further regulates a set of other genes; thus, miR156 controls numerous genes through a complex gene regulation network. Increased axillary branching occurs in transgenic Arabidopsis overexpressing miR156b, similar to that observed in loss-of-function max3 and max4 mutants with lesions in carotenoid cleavage dioxygenases. Arabidopsis miR156b was found to enhance carotenoid levels and reproductive shoot branching when expressed in Brassica napus, suggesting a link between miR156b expression and carotenoid metabolism. However, details of the miR156 regulatory network of SPL genes related to carotenoid metabolism are not known. In this study, an Arabidopsis T-DNA enhancer mutant, sk156, was identified due to its altered branching and trichome morphology and increased seed carotenoid levels compared to wild type (WT) ecovar Columbia. Enhanced miR156b expression due to the 35S enhancers present on the T-DNA insert was responsible for these phenotypes. Constitutive and leaf primodium-specific expression of a miR156-insensitive (mutated) SPL15 (SPL15m) largely restored WT seed carotenoid levels and plant morphology when expressed in sk156. The Arabidopsis native miR156-sensitive SPL15 (SPL15n) and SPL15m driven by a native SPL15 promoter did not restore the WT phenotype in sk156. Our findings suggest that SPL15 function is somewhat redundant with other SPL family members, which collectively affect plant phenotypes. Moreover, substantially decreased miR156b transcript levels in sk156 expressing SPL15m, together with the presence of multiple repeats of SPL-binding GTAC core sequence close to the miR156b transcription start site, suggested feedback regulation of miR156b expression by SPL15. This was supported by the demonstration of specific in vitro interaction between DNA-binding SBP domain of SPL15 and the proximal promoter sequence of miR156b. Enhanced miR156b expression in sk156 leads to the mutant phenotype including carotenoid levels in the seed through suppression of SPL15 and other SPL target genes. Moreover, SPL15 has a regulatory role not only for downstream components, but also for its own upstream regulator miR156b.
Hacki, T
1999-09-01
Voice range profile(VRP) measurement (Phonetography) was used for the evaluation of the vocal capabilities of 41 female (F) and 50 male (M) members of a nonprofessional choir. By means of an automatic VPR measurement system F0 and SPL dB(A) were determined and displayed real time, two-dimensionally. The speaking voice (reading a standard passage as well as counting from the softest to the loudest intensity), the shouting voice (3-4 times shouting a standard sentence) and the singing voice (sustained phonation / la:/ at minimum and maximum intensity level) were measured. The VRPs of these voice modalities were superimposed on the screen and the plot. The averaged values for the speaking VRP: intensity range (F): 48 dB (range 46 soft to 94 dB loud phonation), (M): 52 dB (range 46-98). Pitch range (F): 15 semitones (ST) (Cis3, 138-E4, 329 Hz), (M): 19 ST (E2, 82 Hz-H3, 246 Hz). The average slope for the speaking voice (F): 0,31 ST/dB, (M): 0,36 ST/dB. Shouting VRP highest intensity (F): 106,5 dB, (M): 108,5 dB, highest pitch (F): between Ais4, 466 and H4, 493 Hz. (M): E4, 329 Hz. Average slope for speaking and shouting voice (F): 0,36 ST/dB, (M): 0,39 ST/dB. Singing VRP pitch range (F): 34,6 ST, (M): 37 ST, intensity range (F): 60 dB, (M): 58 dB. The pitch extension of the speaking VRP ranges from 2,9 to 46,2%, speaking and shouting VRPs together with 2,9 to 65% of the pitch range of the singing VRP (F), (M) 2,7-54% and 2,7-67,5% accordingly. The average values for nonprofessional singers reflect an effective but not special use of the phonatory system for the speaking, shouting and singing voice functions with respect to pitch and intensity.
Analysis of transient hypermorphic activity of E(spl)D during R8 specification
Majot, Adam T.
2017-01-01
Drosophila atonal (ato) is required for the specification of founding R8 photoreceptors during retinal development. ato is regulated via dual eye-specific enhancers; ato-3’ is subject to initial induction whereas 5’-ato facilitates Notch-mediated autoregulation. Notch is further utilized to induce bHLH repressors of the E(spl) locus to restrict Ato from its initial broad expression to individual cells. Although Notch operates in two, distinct phases, it has remained unclear how the two phases maintain independence from one another. The difference in these two phases has attributed to the hypothesized delayed expression of E(spl). However, immunofluorescence data indicate that E(spl) are expressed during early Ato patterning, suggesting a more sophisticated underlying mechanism. To probe this mechanism, we provide evidence that although E(spl) exert no influence on ato-3’, E(spl) repress 5’-ato and deletion of the E(spl) locus elicits precocious 5’-ato activity. Thus, E(spl) imposes a delay to the timing in which Ato initiates autoregulation. We next sought to understand this finding in the context of E(spl)D, which encodes a dysregulated variant of E(spl)M8 that perturbs R8 patterning, though, as previously reported, only in conjunction with the mutant receptor Nspl. We established a genetic interaction between E(spl)D and roughened eye (roe), a known modulator of Notch signaling in retinogenesis. This link further suggests a dosage-dependence between E(spl) and the proneural activators Ato and Sens, as indicated via interaction assays in which E(spl)D renders aberrant R8 patterning in conjunction with reduced proneural dosage. In total, the biphasicity of Notch signaling relies, to some degree, on the post-translational regulation of individual E(spl) members and, importantly, that post-translational regulation is likely necessary to modulate the level of E(spl) activity throughout the progression of Ato expression. PMID:29036187
Lanzetti, Manuella; da Costa, Cristiane Aguiar; Nesi, Renata Tiscoski; Barroso, Marina Valente; Martins, Vanessa; Victoni, Tatiana; Lagente, Vincent; Pires, Karla Maria Pereira; e Silva, Patrícia Machado Rodrigues; Resende, Angela Castro; Porto, Luis Cristóvão; Benjamim, Cláudia Farias; Valença, Samuel Santos
2012-12-01
Our aim was to investigate the role of oxidative stress in elastase-induced pulmonary emphysema. C57BL/6 mice were subjected to pancreatic porcine elastase (PPE) instillation (0.05 or 0.5 U per mouse, i.t.) to induce pulmonary emphysema. Lungs were collected on days 7, 14, and 21 after PPE instillation. The control group was sham injected. Also, mice treated with 1% aminoguanidine (AMG) and inducible NO synthase (iNOS) knockout mice received 0.5 U PPE (i.t.), and lungs were analyzed 21 days after. We performed bronchoalveolar lavage, biochemical analyses of oxidative stress, and lung stereology and morphometry assays. Emphysema was observed histologically at 21 days after 0.5 U PPE treatment; tissues from these mice exhibited increased alveolar linear intercept and air-space volume density in comparison with the control group. TNF-α was elevated at 7 and 14 days after 0.5 U PPE treatment, concomitant with a reduction in the IL-10 levels at the same time points. Myeloperoxidase was elevated in all groups treated with 0.5 U PPE. Oxidative stress was observed during early stages of emphysema, with increased nitrite levels and malondialdehyde and superoxide dismutase activity at 7 days after 0.5 U PPE treatment. Glutathione peroxidase activity was increased in all groups treated with 0.5 U PPE. The emphysema was attenuated when iNOS was inhibited using 1% AMG and in iNOS knockout mice. Furthermore, proteolytic stimulation by PPE enhanced the expression of nitrotyrosine and iNOS, whereas the PPE+AMG group showed low expression of iNOS and nitrotyrosine. PPE stimulus also induced endothelial (e) NOS expression, whereas AMG reduced eNOS. Our results suggest that the oxidative and nitrosative stress pathways are triggered by nitric oxide production via iNOS expression in pulmonary emphysema. Copyright © 2012 Elsevier Inc. All rights reserved.
Hall, S; Poller, B; Bailey, C; Gregory, S; Clark, R; Roberts, P; Tunbridge, A; Poran, V; Evans, C; Crook, B
2018-06-01
Variations currently exist across the UK in the choice of personal protective equipment (PPE) used by healthcare workers when caring for patients with suspected high-consequence infectious diseases (HCIDs). To test the protection afforded to healthcare workers by current PPE ensembles during assessment of a suspected HCID case, and to provide an evidence base to justify proposal of a unified PPE ensemble for healthcare workers across the UK. One 'basic level' (enhanced precautions) PPE ensemble and five 'suspected case' PPE ensembles were evaluated in volunteer trials using 'Violet'; an ultraviolet-fluorescence-based simulation exercise to visualize exposure/contamination events. Contamination was photographed and mapped. There were 147 post-simulation and 31 post-doffing contamination events, from a maximum of 980, when evaluating the basic level of PPE. Therefore, this PPE ensemble did not afford adequate protection, primarily due to direct contamination of exposed areas of the skin. For the five suspected case ensembles, 1584 post-simulation contamination events were recorded, from a maximum of 5110. Twelve post-doffing contamination events were also observed (face, two events; neck, one event; forearm, one event; lower legs, eight events). All suspected case PPE ensembles either had post-doffing contamination events or other significant disadvantages to their use. This identified the need to design a unified PPE ensemble and doffing procedure, incorporating the most protective PPE considered for each body area. This work has been presented to, and reviewed by, key stakeholders to decide on a proposed unified ensemble, subject to further evaluation. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Promotion of alternative-sized personal protective equipment.
Flynn, Michael A; Keller, Brenna; DeLaney, Sheli C
2017-12-01
With more diversity in the workforce, companies are producing PPE such as hard hats, safety glasses, coveralls, foot protection, and safety harnesses for a larger range of body shapes and sizes. However, gray literature reports suggest that barriers exist to getting alternate sized PPE from the manufacturer to the workers who need it. The purpose of this study is to determine the extent to which alternative-sized PPE is marketed. A web-based review of seven major manufacturers of PPE was conducted to determine: (a) whether or not they offer alternative-sized products, (b) if these products are clearly labeled, and (c) if images used to display PPE are representative of a diverse workforce. Of the seven PPE manufacturers investigated, six had at least one product that was marketed as gender and/or size alternatives however, alternative sizes were more common for larger body types. Alternative-sized products rarely included size charts, and the models used to display PPE were overwhelmingly white males of average size. Despite the growing availability of alternative-sized PPE, it can be difficult to find these products, which suggests that they are rarely promoted or labeled as alternative-sized. Our study indicates that companies should expand their product lines and more aggressively market and promote these items. Guidance on how to properly fit their products would also be extremely helpful to the end-user. Manufacturers could improve the availability of alternative-sized PPE and increase their promotion of these products on their websites and in their catalogs. Individual companies and safety professionals may assist in this process by demonstrating demand for alternative-sized PPE. Published by Elsevier Ltd.
Whyle, Eleanor Beth; Olivier, Jill
2016-12-01
In low- and middle-income countries (LMICs), the private sector-including international donors, non-governmental organizations, for-profit providers and traditional healers-plays a significant role in health financing and delivery. The use of the private sector in furthering public health goals is increasingly common. By working with the private sector through public -: private engagement (PPE), states can harness private sector resources to further public health goals. PPE initiatives can take a variety of forms and understanding of these models is limited. This paper presents the results of a Campbell systematic literature review conducted to establish the types and the prevalence of PPE projects for health service delivery and financing in Southern Africa. PPE initiatives identified through the review were categorized according to a PPE typology. The review reveals that the full range of PPE models, eight distinct models, are utilized in the Southern African context. The distribution of the available evidence-including significant gaps in the literature-is discussed, and key considerations for researchers, implementers, and current and potential PPE partners are presented. It was found that the literature is disproportionately representative of PPE initiatives located in South Africa, and of those that involve for-profit partners and international donors. A significant gap in the literature identified through the study is the scarcity of information regarding the relationship between international donors and national governments. This information is key to strengthening these partnerships, improving partnership outcomes and capacitating recipient countries. The need for research that disaggregates PPE models and investigates PPE functioning in context is demonstrated. © The Author 2016. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
About Personal Protective Equipment (PPE)
... Equipment for Infection Control Questions About Personal Protective Equipment (PPE) Share Tweet Linkedin Pin it More sharing ... Print Q1. How do manufacturers ensure personal protective equipment (PPE) is safe and effective? A1. To help ...
Zeng, Zhi; Lu, Liming; Rao, Zhanhong; Han, Lu; Shi, Jingrong; Ling, Li
2014-04-01
To investigate the current supply and use of personal protective equipment (PPE) among rural-to-urban migrant workers in small and medium enterprises (SMEs) in Zhongshan and Shenzhen, China and the influential factors for the use of PPE, and to provide a basis for better occupational health services and ensuring the health of migrant workers. Multi-stage sampling was used to select 856 migrant workers from 27 SMEs in Zhongshan and Shenzhen, and face-to-face questionnaire survey was conducted in these subjects. Statistical analysis was performed by one-way analysis of variance, chi-square test, and logistic regression. Of all migrant workers, 38.67%were supplied with free PPE by the factory, and this rate varied across industries (furniture industry: 45.81%; electronic industry: 31.46%) and SMEs (medium enterprises: 42.13%; small enterprises: 39.20%; micro enterprises: 22.16%); 22.43% insisted on the use of PPE. The logistic regression analysis showed that factors associated with the use of PPE included sex, age, awareness of occupational health knowledge, and the size of enterprise. The rates of supply and use of PPE among migrant workers are low. The larger the enterprise, the better the supply of PPE. Male gender, being elder, and high occupational health knowledge score were favorable factors for the use of PPE, while small enterprise size was the unfavorable factor for the use of PPE.
Al-Gubory, Kaïs H; Blachier, François; Faure, Patrice; Garrel, Catherine
2016-08-01
Pomegranate peel extract (PPE) contains several compounds with antioxidative properties. PPE added to foods may interact with endogenous antioxidants and promote health. However, little is known about the biochemical mechanisms by which PPE exerts their actions on tissues of biological systems in vivo. The purpose of this study was to determine the effects of PPE on activities of antioxidant enzymes. Mice were used to investigate the effects of PPE on plasma levels of malondialdehyde (MDA), tissue MDA content and activities of superoxide dismutase 1 (SOD1), SOD2 and glutathione peroxidase (GPX) in the small intestine, liver and skeletal muscle - different tissues involved in the digestion, absorption and metabolism of dietary nutrients. Control mice were fed a standard diet, whereas treated mice were fed for 40 days with the standard diet containing 5% or 10% PPE. Mice fed the 10% PPE diet exhibited lower plasma MDA concentrations, reduced content of MDA in the small intestine and liver and higher levels of SOD1 and GPX activities in the small intestine compared to mice fed the control diet. These findings demonstrate that intake of PPE in diet attenuates small intestine lipid peroxidation and strengthens the first line of small intestine antioxidant defense by enhancing enzymatic antioxidative pathways. PPE is worthy of further study as a therapeutic approach to prevent peroxidative stress-induced gut pathogenesis. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
Rees, Charlotte E; Bradley, Paul; Collett, Tracey; McLachlan, John C
2005-11-01
This study aims to explore quantitatively and qualitatively students' attitudes towards peer physical examination (PPE) and the influence of demographics on students' willingness to participate in PPE. A total of 296 first-year medical students from two consecutive cohorts at the Peninsula Medical School, UK completed the EFS questionnaire. Quantitative data from the questionnaire were analysed using univariate (i.e. Mann-Whitney and chi-squared tests) and multivariate statistics (i.e. stepwise multiple regression) and qualitative data were analysed using theme analysis. At least 92% of Peninsula Medical School students were willing to examine all 11 body parts (except breast and inguinal regions) of peers of same and opposite gender. Qualitative data support this by highlighting students' positive attitudes towards PPE. PPE was more acceptable within rather than across gender and students generally felt more comfortable examining their peers than being examined by peers. Qualitative data outline the range of student concerns with PPE. Significant relationships existed between students' attitudes towards PPE and various variables: gender, age and religious faith. The findings demonstrate that students may show a greater willingness to participate in PPE than previously thought. Further research is required to explore more fully the barriers to PPE.
The accent method of voice therapy: effect of accentuations on FO, SPL, and airflow.
Kotby, M N; Shiromoto, O; Hirano, M
1993-12-01
The effect of the increased flow rate (delta U) in response to the Accent Method exercises on fundamental frequency (FO) and sound pressure level (SPL) was studied in three subjects (professionally trained, trained, and untrained in this method). In all the subjects, the rhythmic accentuated exercises produced a variable degree of increase in FO (delta FO) and SPL (delta SPL). The professionally trained subject showed greater delta FO and delta SPL in response to the delta U in the fastest tempo, which requires higher skills. Both trained subjects showed a greater correlation between delta U and both delta SPL and delta FO, as well as between delta FO and delta SPL, as compared to the untrained subject. The effects of the accentuated exercises on FO and SPL in response to the increased airflow rate (delta U) thus appear to demonstrate the treating effectiveness of the Accent Method.
Weiss, Deike; Infante-Duarte, Carmen; Salbach-Andrae, Harriet; Burghardt, Roland; Hamann, Isabell; Pfeiffer, Ernst; Lehmkuhl, Ulrike; Ehrlich, Stefan
2010-08-01
The prohormone preproenkephalin (ppE) and its derived peptides are involved in leukocyte functioning as well as in the regulation of hunger and satiety. Various abnormalities of the immune and endocrine systems have been described in states of malnutrition such as anorexia nervosa (AN). We hypothesized that ppE expression in AN patients may vary depending on the state of the disorder and the extent of malnutrition. Expression of ppE mRNA was analysed in peripheral blood mononuclear cells of 29 underweight and 29 weight-recovered patients with AN and compared to that in 29 healthy control women. The extent of malnutrition was characterized by BMI and plasma leptin. Psychological distress and eating disorder specific-psychopathology was determined with the Symptom Checklist-90-Revised and the Eating Disorders Inventory-2. ppE gene expression was similar in all 3 groups and was not related to nutritional status or eating disorder symptoms. However, a significant negative correlation was found between ppE expression and obsessive-compulsive, depressive and anxious symptoms. In addition, ppE expression was higher in smokers compared to non-smokers. Although malnutrition and hypoleptinaemia as seen in patients with AN were not related to peripheral ppE expression, we demonstrated reduced ppE expression in patients with elevated psychological distress. Similar associations have been shown in animal models of stress. It remains speculative if psychological symptoms and/or stress may augment immune abnormalities in AN patients via a pathway that is independent of nutritional status and involves ppE. (c) 2010 S. Karger AG, Basel.
Selecting PPE for the Workplace (Personal Protective Equipment for the Eyes and Face)
... Additional References Site Map Credits Selecting Personal Protective Equipment (PPE) for the Workplace Impact Heat Chemicals Dust Optical Radiation OSHA Requirements Home | Selecting Personal Protective Equipment (PPE) for the Workplace | OSHA Requirements Site Map | ...
Air traffic controllers' long-term speech-in-noise training effects: A control group study.
Zaballos, Maria T P; Plasencia, Daniel P; González, María L Z; de Miguel, Angel R; Macías, Ángel R
2016-01-01
Speech perception in noise relies on the capacity of the auditory system to process complex sounds using sensory and cognitive skills. The possibility that these can be trained during adulthood is of special interest in auditory disorders, where speech in noise perception becomes compromised. Air traffic controllers (ATC) are constantly exposed to radio communication, a situation that seems to produce auditory learning. The objective of this study has been to quantify this effect. 19 ATC and 19 normal hearing individuals underwent a speech in noise test with three signal to noise ratios: 5, 0 and -5 dB. Noise and speech were presented through two different loudspeakers in azimuth position. Speech tokes were presented at 65 dB SPL, while white noise files were at 60, 65 and 70 dB respectively. Air traffic controllers outperform the control group in all conditions [P<0.05 in ANOVA and Mann-Whitney U tests]. Group differences were largest in the most difficult condition, SNR=-5 dB. However, no correlation between experience and performance were found for any of the conditions tested. The reason might be that ceiling performance is achieved much faster than the minimum experience time recorded, 5 years, although intrinsic cognitive abilities cannot be disregarded. ATC demonstrated enhanced ability to hear speech in challenging listening environments. This study provides evidence that long-term auditory training is indeed useful in achieving better speech-in-noise understanding even in adverse conditions, although good cognitive qualities are likely to be a basic requirement for this training to be effective. Our results show that ATC outperform the control group in all conditions. Thus, this study provides evidence that long-term auditory training is indeed useful in achieving better speech-in-noise understanding even in adverse conditions.
NASA Technical Reports Server (NTRS)
Pla, Frederic G.; Hu, Ziqiang; Sutliff, Daniel L.
1996-01-01
This report describes the Active Noise Cancellation (ANC) System designed by General Electric and tested in the NASA Lewis Research Center's (LERC) 48 inch Active Noise Control Fan (ANCF). The goal of this study is to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for global active noise cancellation of fan tones. The GE ANC system is based on a modal control approach. A known acoustic mode propagating in the fan duct is canceled using an array of flush-mounted compact sound sources. The canceling modal signal is generated by a modal controller. Inputs to the controller are signals from a shaft encoder and from a microphone array which senses the residual acoustic mode in the duct. The key results are that the (6,0) was completely eliminated at the 920 Hz design frequency and substantially reduced elsewhere. The total tone power was reduced 6.8 dB (out of a possible 9.8 dB). Farfield reductions of 15 dB (SPL) were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB PWL decrease. The results indicate that global attenuation of PWL at the target frequency was obtained in the aft quadrant using an ANC actuator and sensor system totally contained within the duct. The quality of the results depended on precise mode generation. High spillover into spurious modes generated by the ANC actuator array caused less than optimum levels of PWL reduction. The variation in spillover is believed to be due to calibration procedure, but must be confirmed in subsequent tests.
Perception of peer physical examination in two Australian osteopathy programs.
Vaughan, Brett; Grace, Sandra
2016-01-01
Peer physical examination (PPE) is an efficient and practical educational approach whereby students can practise their examination skills on each other before commencing clinical practice with actual patients. Little is known about the use of PPE in osteopathy education. Students in Year 1 of the osteopathy programs at Victoria University (Melbourne, Australia) and Southern Cross University (Lismore, Australia) completed the Examining Fellow Students and the Peer Physical Examination questionnaires prior to, and at the completion of, their first 12-week teaching session. Descriptive statistics were generated for each questionnaire. The McNemar and sign tests were used to evaluate differences between each questionnaire administration. Logistic regression was used to evaluate the influence of demographics on responses to both questionnaires. Results showed that students in both programs were generally willing to examine non-sensitive areas both before and after the 12-week teaching session. Students' were less apprehensive about PPE at the end of the teaching session, and this was reinforced by results for previous exposure to PPE in other courses. Consistent with previous studies, unwillingness to participate in PPE was associated with being female, being born outside Australia, holding religious beliefs, and being older. This is the first study to explore students' perceptions of PPE in this cohort and provides a basis for further work, including evaluating longer term changes in student perception of PPE, and whether these perceptions extend to practising manual therapy techniques. This study demonstrates that perceptions about PPE reported in medicine and other disciplines, namely that unwillingness to participate in PPE is associated with being female, being born outside Australia, holding religious beliefs, and being older, also apply to osteopathy. These findings are significant for all manual therapy students who spend a substantial portion of their course developing skills in PPE and practising manual therapy techniques. They highlight the need for curriculum development that acknowledges the importance of good practice in PPE, including discussions about body image, feedback skills training for educators, and providing detailed information to students about what to expect in practical skills classes before they commence their course.
Schmidt, Arne K D; Römer, Heiner
2011-01-01
Insects often communicate by sound in mixed species choruses; like humans and many vertebrates in crowded social environments they thus have to solve cocktail-party-like problems in order to ensure successful communication with conspecifics. This is even more a problem in species-rich environments like tropical rainforests, where background noise levels of up to 60 dB SPL have been measured. Using neurophysiological methods we investigated the effect of natural background noise (masker) on signal detection thresholds in two tropical cricket species Paroecanthus podagrosus and Diatrypa sp., both in the laboratory and outdoors. We identified three 'bottom-up' mechanisms which contribute to an excellent neuronal representation of conspecific signals despite the masking background. First, the sharply tuned frequency selectivity of the receiver reduces the amount of masking energy around the species-specific calling song frequency. Laboratory experiments yielded an average signal-to-noise ratio (SNR) of -8 dB, when masker and signal were broadcast from the same side. Secondly, displacing the masker by 180° from the signal improved SNRs by further 6 to 9 dB, a phenomenon known as spatial release from masking. Surprisingly, experiments carried out directly in the nocturnal rainforest yielded SNRs of about -23 dB compared with those in the laboratory with the same masker, where SNRs reached only -14.5 and -16 dB in both species. Finally, a neuronal gain control mechanism enhances the contrast between the responses to signals and the masker, by inhibition of neuronal activity in interstimulus intervals. Thus, conventional speaker playbacks in the lab apparently do not properly reconstruct the masking noise situation in a spatially realistic manner, since under real world conditions multiple sound sources are spatially distributed in space. Our results also indicate that without knowledge of the receiver properties and the spatial release mechanisms the detrimental effect of noise may be strongly overestimated.
Ravicz, Michael E.; Melcher, Jennifer R.
2007-01-01
Approaches were examined for reducing acoustic noise levels heard by subjects during functional magnetic resonance imaging (fMRI), a technique for localizing brain activation in humans. Specifically, it was examined whether a device for isolating the head and ear canal from sound (a “helmet”) could add to the isolation provided by conventional hearing protection devices (i.e., earmuffs and earplugs). Both subjective attenuation (the difference in hearing threshold with versus without isolation devices in place) and objective attenuation (difference in ear-canal sound pressure) were measured. In the frequency range of the most intense fMRI noise (1–1.4 kHz), a helmet, earmuffs, and earplugs used together attenuated perceived sound by 55–63 dB, whereas the attenuation provided by the conventional devices alone was substantially less: 30–37 dB for earmuffs, 25–28 dB for earplugs, and 39–41 dB for earmuffs and earplugs used together. The data enabled the clarification of the relative importance of ear canal, head, and body conduction routes to the cochlea under different conditions: At low frequencies (≤500 Hz), the ear canal was the dominant route of sound conduction to the cochlea for all of the device combinations considered. At higher frequencies (>500 Hz), the ear canal was the dominant route when either earmuffs or earplugs were worn. However, the dominant route of sound conduction was through the head when both earmuffs and earplugs were worn, through both ear canal and body when a helmet and earmuffs were worn, and through the body when a helmet, earmuffs, and earplugs were worn. It is estimated that a helmet, earmuffs, and earplugs together will reduce the most intense fMRI noise levels experienced by a subject to 60–65 dB SPL. Even greater reductions in noise should be achievable by isolating the body from the surrounding noise field. PMID:11206150
Schmidt, Arne K. D.; Römer, Heiner
2011-01-01
Background Insects often communicate by sound in mixed species choruses; like humans and many vertebrates in crowded social environments they thus have to solve cocktail-party-like problems in order to ensure successful communication with conspecifics. This is even more a problem in species-rich environments like tropical rainforests, where background noise levels of up to 60 dB SPL have been measured. Principal Findings Using neurophysiological methods we investigated the effect of natural background noise (masker) on signal detection thresholds in two tropical cricket species Paroecanthus podagrosus and Diatrypa sp., both in the laboratory and outdoors. We identified three ‘bottom-up’ mechanisms which contribute to an excellent neuronal representation of conspecific signals despite the masking background. First, the sharply tuned frequency selectivity of the receiver reduces the amount of masking energy around the species-specific calling song frequency. Laboratory experiments yielded an average signal-to-noise ratio (SNR) of −8 dB, when masker and signal were broadcast from the same side. Secondly, displacing the masker by 180° from the signal improved SNRs by further 6 to 9 dB, a phenomenon known as spatial release from masking. Surprisingly, experiments carried out directly in the nocturnal rainforest yielded SNRs of about −23 dB compared with those in the laboratory with the same masker, where SNRs reached only −14.5 and −16 dB in both species. Finally, a neuronal gain control mechanism enhances the contrast between the responses to signals and the masker, by inhibition of neuronal activity in interstimulus intervals. Conclusions Thus, conventional speaker playbacks in the lab apparently do not properly reconstruct the masking noise situation in a spatially realistic manner, since under real world conditions multiple sound sources are spatially distributed in space. Our results also indicate that without knowledge of the receiver properties and the spatial release mechanisms the detrimental effect of noise may be strongly overestimated. PMID:22163041
Frontal auditory evoked potentials and augmenting-reducing.
Bruneau, N; Roux, S; Garreau, B; Lelord, G
1985-09-01
Auditory evoked potentials (AEPs) to tones (750 Hz--200 msec) ranging from 50 to 80 dB SPL were studied at Cz and Fz leads in 29 normal adults (15 males) ranging in age from 20 to 22. Peak-to-trough amplitudes were measured for the P1-N1 and the N1-P2 wave forms as well as baseline (500 msec prestimulus)-to-peak amplitudes for each component, i.e., P1, N1 and P2. Amplitudes were examined as a function of intensity and electrode location. Cz-Fz amplitude differences increased with increasing stimulus intensity, the differentiating peak being the N1 component. An overall reducing phenomenon was found at Fz in the 70-80 dB range whereas an augmenting effect was observed at Cz for these intensities. The augmenting/reducing groups defined by analysis of individual amplitude-intensity patterns were different whether we considered Fz or Cz results: Fz reducers were more numerous than Cz reducers. These results on prominent reducing at the frontal level were examined in relation to the data concerning the modulatory function of the frontal cortex on auditory EPs. Implications were drawn for the role of the frontal cortex in cortical augmenting-reducing.
Noise at the neonatal intensive care unit and inside the incubator.
Pinheiro, Eliana Moreira; Guinsburg, Ruth; Nabuco, Marco Antonio de Araujo; Kakehashi, Tereza Yoshiko
2011-01-01
The goal was to identify sound pressure level (SPL) at the neonatal intensive care unit (NICU) and inside the incubator of a teaching hospital of a public university from São Paulo - SP, Brazil. SPL inside the NICU and the incubator were measured using four dosimeters in January/2010. SPL at the NICU varied from 52.6 dBA to 80.4 dBA and inside the incubator, from 45.4 dBA to 79.1 dBA. SPL both at the NICU and inside the incubator are above the recommended values, but levels were higher at the NICU than inside the incubator. Although there are some specific factors related to SPL inside the incubator, the NICU and incubator acoustic features present a system: an increase/decrease in SPL at the NICU usually tends to increase/decrease SPL inside the incubator. The study points to the need for simultaneous monitoring of SPL at the NICU and inside the incubator.
Rees, Charlotte E
2007-08-01
Previous research has consistently found a relationship between students' attitudes towards peer physical examination (PPE) and their gender. Male students are more comfortable with PPE than females and students are more comfortable with same- rather than mixed-gender PPE. Despite these findings, previous research has not discussed the gender-attitude relationship in any meaningful depth. This discussion paper examines why a relationship exists between student attitudes towards PPE and student gender using insights from feminist body image theory. According to the feminist theory of objectified body consciousness, females experience their bodies differently from males. Females may be less comfortable with PPE because they have higher levels of body shame and body surveillance than males. They may also be more likely than males to fear critical and teasing comments and sexual objectification by the opposite sex. Capitalizing on what we already know about psychoeducational and activism approaches to the prevention and change of negative body image, I recommend that body image issues are discussed as part of students' PPE and professionalism programmes. Further research is needed to examine medical students' body image alongside their attitudes towards PPE.
Influence of rate of change of frequency on the overall pitch of frequency-modulated tones.
Gockel, H; Moore, B C; Carlyon, R P
2001-02-01
The mechanism(s) determining pitch may assign less weight to portions of a sound where the frequency is changing rapidly. The present experiments explored the possible effect of this on the overall pitch of frequency-modulated sounds. Pitch matches were obtained between an adjustable unmodulated sinusoid and a sinusoidal carrier that was frequency modulated using a highly asymmetric function with the form of a repeating U or inverted U shaped function. The amplitude was constant during the 400-ms presentation time of each stimulus, except for 10-ms raised-cosine onset and offset ramps. In experiment 1, the carrier level was 50 dB SPL and the geometric mean of the instantaneous frequency of the modulated carrier, fc, was either 0.5, 1, 2, or 8 kHz. The modulation rate (fm) was 5, 10, or 20 Hz. The overall depth (maximum to minimum) of the FM was 8% of fc. For all carrier frequencies, the matched frequency was shifted away from the mean carrier frequency, downwards for the U shaped function stimuli and upwards for the repeated inverted U shaped function stimuli. The shift was typically slightly greater than 1% of fc, and did not vary markedly with fc. The effect of fm was small, but there was a trend for the shifts to decrease with increasing fm for fc = 0.5 kHz and to increase with increasing fm for fc = 2 kHz. In experiment 2, the carrier level was reduced to 20 dB SL and matches were obtained only for fc = 2 kHz. Shifts in matched frequency of about 1% were still observed, but the trend for the shifts to increase with increasing fm no longer occurred. In experiment 3, matches were obtained for a 4-kHz carrier at 50 dB SPL. Shifts of about 1% again occurred, which did not vary markedly with fm. The shifts in matched frequency observed in all three experiments are not predicted by models based on the amplitude- or intensity-weighted average of instantaneous frequency (EWAIF or IWAIF). The shifts (and the pitch shifts observed earlier for two-tone complexes and for stimuli with simultaneous AM and FM) are consistent with a model based on the assumption that the overall pitch of a frequency-modulated sound is determined from a weighted average of period estimates, with the weight attached to a given estimate being inversely related to the short-term rate of change of period and directly related to a compressive function of the amplitude.
New PPE Policy Will Help Prevent Injuries | Poster
By Ashley Shoemaker, Guest Writer In January 2013, a revised policy on personal protective equipment (PPE) was approved for all government and contractor employees at NCI at Frederick. This new policy was driven by a high number of eye injuries at NCI at Frederick (56 between 2007 and 2012) that were directly related to inadequate PPE. The Occupational Safety and Health Act states that each employer is responsible for identifying hazards in the workplace and determining what kind of PPE is necessary.
Physical Performance Decrements in Military Personnel Wearing Personal Protective Equipment (PPE)
2009-10-01
remaining out of the testing position for more than 5 seconds. For the NeuroCom SOT, subjects were asked to stand on the force plate with the...PPE) P2 - 2 RTO-MP-HFM-181 and without a PPE system of Kevlar® front and back plates and an unlined combat helmet. The average mass of the PPE...in four different postural conditions immediately before and after the treadmill (exercise) test. All participants stood on a Bertec force platform
Dynamics of infant cortical auditory evoked potentials (CAEPs) for tone and speech tokens.
Cone, Barbara; Whitaker, Richard
2013-07-01
Cortical auditory evoked potentials (CAEPs) to tones and speech sounds were obtained in infants to: (1) further knowledge of auditory development above the level of the brainstem during the first year of life; (2) establish CAEP input-output functions for tonal and speech stimuli as a function of stimulus level and (3) elaborate the data-base that establishes CAEP in infants tested while awake using clinically relevant stimuli, thus providing methodology that would have translation to pediatric audiological assessment. Hypotheses concerning CAEP development were that the latency and amplitude input-output functions would reflect immaturity in encoding stimulus level. In a second experiment, infants were tested with the same stimuli used to evoke the CAEPs. Thresholds for these stimuli were determined using observer-based psychophysical techniques. The hypothesis was that the behavioral thresholds would be correlated with CAEP input-output functions because of shared cortical response areas known to be active in sound detection. 36 infants, between the ages of 4 and 12 months (mean=8 months, s.d.=1.8 months) and 9 young adults (mean age 21 years) with normal hearing were tested. First, CAEPs amplitude and latency input-output functions were obtained for 4 tone bursts and 7 speech tokens. The tone bursts stimuli were 50 ms tokens of pure tones at 0.5, 1.0, 2.0 and 4.0 kHz. The speech sound tokens, /a/, /i/, /o/, /u/, /m/, /s/, and /∫/, were created from natural speech samples and were also 50 ms in duration. CAEPs were obtained for tone burst and speech token stimuli at 10 dB level decrements in descending order from 70 dB SPL. All CAEP tests were completed while the infants were awake and engaged in quiet play. For the second experiment, observer-based psychophysical methods were used to establish perceptual threshold for the same speech sound and tone tokens. Infant CAEP component latencies were prolonged by 100-150 ms in comparison to adults. CAEP latency-intensity input output functions were steeper in infants compared to adults. CAEP amplitude growth functions with respect to stimulus SPL are adult-like at this age, particularly for the earliest component, P1-N1. Infant perceptual thresholds were elevated with respect to those found in adults. Furthermore, perceptual thresholds were higher, on average, than levels at which CAEPs could be obtained. When CAEP amplitudes were plotted with respect to perceptual threshold (dB SL), the infant CAEP amplitude growth slopes were steeper than in adults. Although CAEP latencies indicate immaturity in neural transmission at the level of the cortex, amplitude growth with respect to stimulus SPL is adult-like at this age, particularly for the earliest component, P1-N1. The latency and amplitude input-output functions may provide additional information as to how infants perceive stimulus level. The reasons for the discrepancy between electrophysiologic and perceptual threshold may be due to immaturity in perceptual temporal resolution abilities and the broad-band listening strategy employed by infants. The findings from the current study can be translated to the clinical setting. It is possible to use tonal or speech sound tokens to evoke CAEPs in an awake, passively alert infant, and thus determine whether these sounds activate the auditory cortex. This could be beneficial in the verification of hearing aid or cochlear implant benefit. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Efficacy of passive acoustic screening: implications for the design of imager and MR-suite.
Moelker, Adriaan; Vogel, Mika W; Pattynama, Peter M T
2003-02-01
To investigate the efficacy of passive acoustic screening in the magnetic resonance (MR) environment by reducing direct and indirect MR-related acoustic noise, both from the patient's and health worker's perspective. Direct acoustic noise refers to sound originating from the inner and outer shrouds of the MR imager, and indirect noise to acoustic reflections from the walls of the MR suite. Sound measurements were obtained inside the magnet bore (patient position) and at the entrance of the MR imager (health worker position). Inner and outer shrouds and walls were lined with thick layers of sound insulation to eliminate the direct and indirect acoustic pathways. Sound pressure levels (SPLs) and octave band frequencies were acquired during various MR imaging sequences at 1.5 T. Inside the magnet bore, direct acoustic noise radiating from the inner shroud was most relevant, with substantial reductions of up to 18.8 dB when using passive screening of the magnetic bore. At the magnet bore entrance, blocking acoustic noise from the outer shroud and reflections showed significant reductions of 4.5 and 2.8 dB, respectively, and 9.4 dB when simultaneously applied. Inner shroud coverage contributed minimally to the overall SPL reduction. Maximum noise reduction by passive acoustic screening can be achieved by reducing direct sound conduction through the inner and outer shrouds. Additional measures to optimize the acoustic properties of the MR suite have only little effect. Copyright 2003 Wiley-Liss, Inc.
McFadden, Sandra L.; Ding, Da-Lian; Lear, Patricia M.; Ho, Ye-Shih
2000-01-01
Reactive oxygen species (ROS) and oxidative stress have been implicated in cochlear injury following loud noise and ototoxins. Genetic mutations that impair antioxidant defenses would be expected to increase cochlear injury following acute insults and to contribute to cumulative injury that presents as age-related hearing loss. We examined whether genetically based deficiency of cellular glutathione peroxidase, a major antioxidant enzyme, increases noise-induced hearing loss in mice. Two-month-old "knockout" mice with a targeted inactivating mutation of the gene coding for glutathione peroxidase (Gpx1) and wild type controls were exposed to broadband noise for one hour at 110 dB SPL. Auditory brainstem response (ABR) thresholds at test frequencies ranging from 5 to 40 kHz were obtained two and four weeks after exposure to determine the stable permanent component of the hearing loss. Depending on test frequency, Gpx1 knockout mice showed up to 16 dB higher ABR thresholds prior to noise exposure, and up to 15 dB greater noise-induced hearing loss, compared with controls. Within the cochlear base, there was also a significant contribution of the knockout to inner and outer hair cell loss, as well as nerve fiber loss. Our results support a link between genetic impairment of antioxidant defenses, vulnerability of the cochlea injury, and cochlear degeneration. Such impairment produces characteristics expected of some mutations associated with age-related hearing loss and offers one possible mechanism for their action. PMID:11545230
Davidson, Lisa S; Geers, Ann E; Brenner, Christine
2010-10-01
Updated cochlear implant technology and optimized fitting can have a substantial impact on speech perception. The effects of upgrades in processor technology and aided thresholds on word recognition at soft input levels and sentence recognition in noise were examined. We hypothesized that updated speech processors and lower aided thresholds would allow improved recognition of soft speech without compromising performance in noise. 109 teenagers who had used a Nucleus 22-cochlear implant since preschool were tested with their current speech processor(s) (101 unilateral and 8 bilateral): 13 used the Spectra, 22 the ESPrit 22, 61 the ESPrit 3G, and 13 the Freedom. The Lexical Neighborhood Test (LNT) was administered at 70 and 50 dB SPL and the Bamford Kowal Bench sentences were administered in quiet and in noise. Aided thresholds were obtained for frequency-modulated tones from 250 to 4,000 Hz. Results were analyzed using repeated measures analysis of variance. Aided thresholds for the Freedom/3G group were significantly lower (better) than the Spectra/Sprint group. LNT scores at 50 dB were significantly higher for the Freedom/3G group. No significant differences between the 2 groups were found for the LNT at 70 or sentences in quiet or noise. Adolescents using updated processors that allowed for aided detection thresholds of 30 dB HL or better performed the best at soft levels. The BKB in noise results suggest that greater access to soft speech does not compromise listening in noise.
Factors influencing worker use of personal protective eyewear.
Lombardi, David A; Verma, Santosh K; Brennan, Melanye J; Perry, Melissa J
2009-07-01
To identify and describe the array of factors that influence a workers' decision to wear personal protective eyewear (PPE) and the barriers that exist in preventing their use. A series of focus groups enrolled workers and supervisors primarily from manufacturing, construction, or service/retail industries that had potential exposure to eye injury hazards in their job tasks. Focus group sessions were facilitated to collect qualitative and quantitative data in two categories, "sought information" and "emergent themes", related to the factors influencing use of PPE. We conducted a series of 7 groups with 51 participants, 36 (71%) males and 15 (29%) females ranging in age from 19 to 64 years old, from a variety of occupations including construction (24%), production (22%), installation, repair and maintenance (14%), and healthcare (10%). Most were highly experienced in their occupation (>10 years); males (86%) and females (53%), and had received some safety training in the past (82%). The majority of workers in this study were required to wear PPE on their worksite (78%), however only 55% had a dedicated safety officer. A conceptual model that summarizes the "sought information" and "emergent themes" is presented that depicts the decision making process for the factors influencing use of PPE and consists of three primary branches; perceptions of hazards and risks, "barriers" to PPE usage, and enforcement and reinforcement. Lack of comfort/fit, and fogging and scratching of the eyewear were suggested as the most important barriers to PPE usage. Younger age and lack of safety training were other important factors affecting use of PPE. Several potentially modifiable factors identified would lead to an increase in workers' PPE use and encourage supervisors to provide ongoing positive feedback on the continuous use of PPE by workers at risk for an eye injury.
Quality of care and investment in property, plant, and equipment in hospitals.
Levitt, S W
1994-02-01
This study explores the relationship between quality of care and investment in property, plant, and equipment (PPE) in hospitals. Hospitals' investment in PPE was derived from audited financial statements for the fiscal years 1984-1989. Peer Review Organization (PRO) Generic Quality Screen (GQS) reviews and confirmed failures between April 1989 and September 1990 were obtained from the Massachusetts PRO. Weighted least squares regression models used PRO GQS confirmed failure rates as the dependent variable, and investment in PPE as the key explanatory variable. Investment in PPE was standardized, summed by the hospital over the six years, and divided by the hospital's average number of beds in that period. The number of PRO reviewed cases with one or more GQS confirmed failures was divided by the total number of cases reviewed to create confirmed failure rates. Investment in PPE in Massachusetts hospitals is correlated with GQS confirmed failure rates. A financial variable, investment in PPE, predicts certain dimensions of quality of care in hospitals.
Akhter, Yusuf; Ehebauer, Matthias T; Mukhopadhyay, Sangita; Hasnain, Seyed E
2012-01-01
The PE/PPE multigene family codes for approximately 10% of the Mycobacterium tuberculosis proteome and is encoded by 176 open reading frames. These proteins possess, and have been named after, the conserved proline-glutamate (PE) or proline-proline-glutamate (PPE) motifs at their N-terminus. Their genes have a conserved structure and repeat motifs that could be a potential source of antigenic variation in M. tuberculosis. PE/PPE genes are scattered throughout the genome and PE/PPE pairs are usually encoded in bicistronic operons although this is not universally so. This gene family has evolved by specific gene duplication events. PE/PPE proteins are either secreted or localized to the cell surface. Several are thought to be virulence factors, which participate in evasion of the host immune response. This review summarizes the current knowledge about the gene family in order to better understand its biological function. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Access to properly fitting personal protective equipment for female construction workers.
Onyebeke, Lynn C; Papazaharias, Demetrios M; Freund, Alice; Dropkin, Jonathan; McCann, Michael; Sanchez, Sadie H; Hashim, Dana; Meyer, John D; Lucchini, Roberto G; Zuckerman, Norman C
2016-11-01
Previous literature suggests that most personal protective equipment (PPE) for construction is designed for males and does not accommodate female anthropometry. We conducted a pilot study to identify whether female construction workers currently have adequate access to properly fitting PPE. Semi-structured focus group interviews were conducted with union female carpenters, laborers, and ironworkers. Researchers coded focus group transcriptions and extracted major themes using thematic framework analysis. Participants (n = 23) had a mean of 15.1 years of construction experience (range 3-34.5 years). A majority reported fit problems for many types of PPE (gloves, harnesses, safety vests, work boots, outerwear), generally noting that the equipment provided by contractors was too large. Other emergent themes included female workers purchasing their own PPE, exposure to various safety hazards from poorly fitted PPE, and perceived indifferent safety culture. Female construction workers continue to have difficulty accessing properly fitting PPE. Am. J. Ind. Med. 59:1032-1040, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Bhat, Khalid Hussain; Srivastava, Shruti; Kotturu, Sandeep Kumar; Ghosh, Sudip; Mukhopadhyay, Sangita
2017-01-01
Mycobacterium tuberculosis, the bacterium that causes tuberculosis, is one of the most successful pathogens of humans. It has evolved several adaptive skills and evasion mechanisms to hijack the immunologically educated host to suit its intracellular lifestyle. Here, we show that one of the unique PPE family member proteins of M. tuberculosis, PPE2, can limit nitric oxide (NO) production by inhibiting inos gene transcription. PPE2 protein has a leucine zipper DNA-binding motif and a functional nuclear localization signal. PPE2 was translocated into the macrophage nucleus via the classical importin α/β pathway where it interacted with a GATA-binding site overlapping with the TATA box of inos promoter and inhibited NO production. PPE2 prolonged intracellular survival of a surrogate bacterium M. smegmatis in vitro as well as in vivo. This information are likely to improve our knowledge of host-pathogen interactions during M. tuberculosis infection which is crucial for designing effective anti-TB therapeutics. PMID:28071726
Olson, Ryan; Grosshuesch, Ariel; Schmidt, Sara; Gray, Mary; Wipfli, Bradley
2009-10-01
The current project evaluated the effects of the collective behavior of multiple social models on the use of personal protective equipment (PPE). Prior to completing a simulated baggage-screening task, participants (N=64) watched a scripted training video that included three confederate trainees. Participants were randomly assigned to one of four manipulations, where different proportions of confederates were shown putting on over-ear sound mufflers before starting the task (0, 1, 2, or 3). White noise played at 70 decibels in the test room, and PPE use was observed unobtrusively through a lab window at five time intervals. The mean intervals of PPE use generally increased as the number of positive social models increased (0=0.63, 1=0.50, 2=1.25, 3=3.06), and differences between groups were significant [chi(2) (3, N=64)=14.92, p<.01, eta(2)=0.24]. The results suggest that the aggregate prevalence of safety behavior within work groups may be an important determinant of initial PPE use by new employees. Results suggest that new hires are likely to use PPE at a rate that is proportional to the collective PPE use observed among their peers. Safety leaders should regularly measure the collective level of PPE use at job sites and encourage majority usage through appropriate interventions such as increasing the availability or quality of PPE, training, or positive reinforcement for compliance.
Cuddington, Erin; Shin, Jason J; Frank, Rachel M
2016-03-01
Our aim was to examine inclusion of screening questions related to female athlete triad in the Canadian Interuniversity Sport (CIS) pre-participation evaluation (PPE) forms. We hypothesized that the current CIS PPE forms are not comprehensive screening tools for identifying athletes at risk for the female athlete triad. All 48 English-speaking CIS universities were invited to participate in the study. Via e-mail, a copy of the PPE form was requested from team physicians and certified athletic trainers. Two reviewers evaluated the PPE forms for inclusion of the 12 items recommended by the Female Athlete Triad Coalition for primary screening for the triad. Thirty-nine of 48 CIS universities responded (81%). The majority of the universities (97%), required a PPE for incoming athletes. Only 9 universities (24%) had 6 or more of the 12 recommended screening items included in their forms, whereas 26 universities (70%) included 4 or less items. Three universities (8%) did not address any of the recommended questions. Questions related to disordered eating were often absent in the collected PPEs. In 10 universities (27%), PPE forms were completed by the athlete alone. The remaining 27 (73%) universities required the form to be completed by the athlete in conjunction with a therapist, physician, or both. PPE forms used by CIS universities have limited ability to identify athletes at risk of the triad-based on the recommendations of the Coalition. Furthermore, there is a lack of uniformity of the PPE forms within the CIS.
Micromachined microphone array on a chip for turbulent boundary layer measurements
NASA Astrophysics Data System (ADS)
Krause, Joshua Steven
A surface micromachined microphone array on a single chip has been successfully designed, fabricated, characterized, and tested for aeroacoustic purposes. The microphone was designed to have venting through the diaphragm, 64 elements (8x8) on the chip, and used a capacitive transduction scheme. The microphone was fabricated using the MEMSCAP PolyMUMPs process (a foundry polysilicon surface micromachining process) along with facilities at Tufts Micro and Nano Fabrication Facility (TMNF) where a Parylene-C passivation layer deposition and release of the microstructures were performed. The devices are packaged with low profile interconnects, presenting a maximum of 100 mum of surface topology. The design of an individual microphone was completed through the use of a lumped element model (LEM) to determine the theoretical performance of the microphone. Off-chip electronics were created to allow the microphone array outputs to be redirected to one of two channels, allowing dynamic reconfiguration of the effective transducer shape in software and provide 80 dB off isolation. The characterization was completed through the use of laser Doppler vibrometry (LDV), acoustic plane wave tube and free-field calibration, and electrical noise floor testing in a Faraday cage. Measured microphone sensitivity is 0.15 mV/Pa for an individual microphone and 8.7 mV/Pa for the entire array, in close agreement with model predictions. The microphones and electronics operate over the 200--40 000 Hz band. The dynamic range extends from 60 dB SPL in a 1 Hz band to greater than 150 dB SPL. Element variability was +/-0.05 mV/Pa in sensitivity with an array yield of 95%. Wind tunnel testing at flow rates of up to 205.8 m/s indicates that the devices continue to operate in flow without damage, and can be successfully reconfigured on the fly. Care has been taken to systematically remove contaminating signals (acoustic, vibration, and noise floor) from the wind tunnel data to determine actual turbulent pressure fluctuations beneath the turbulent boundary layer to an uncertainty level of 1 dB. Analysis of measured boundary layer pressure spectra at six flow rates from 34.3 m/s to 205.8 m/s indicate single point wall spectral measurements in close agreement to the empirical models of Goody, Chase-Howe, and Efimtsov above Mach 0.4. The MEMS data more closely resembles the magnitude of the Efimtsov model at higher frequencies (25% higher above 3 kHz for the Mach 0.6 case); however, the shape of the spectral model is closer to the model of Goody (50% lower for the Mach 0.6 case for all frequencies). The Chase-Howe model does fall directly on the MEMS data starting at 6 kHz, but has a sharper slope and does not resemble the data at below 6 kHz.
High-Speed Automatic Microscopy for Real Time Tracks Reconstruction in Nuclear Emulsion
NASA Astrophysics Data System (ADS)
D'Ambrosio, N.
2006-06-01
The Oscillation Project with Emulsion-tRacking Apparatus (OPERA) experiment will use a massive nuclear emulsion detector to search for /spl nu//sub /spl mu///spl rarr//spl nu//sub /spl tau// oscillation by identifying /spl tau/ leptons through the direct detection of their decay topology. The feasibility of experiments using a large mass emulsion detector is linked to the impressive progress under way in the development of automatic emulsion analysis. A new generation of scanning systems requires the development of fast automatic microscopes for emulsion scanning and image analysis to reconstruct tracks of elementary particles. The paper presents the European Scanning System (ESS) developed in the framework of OPERA collaboration.
Spent Pot Lining Characterization Framework
NASA Astrophysics Data System (ADS)
Ospina, Gustavo; Hassan, Mohamed I.
2017-09-01
Spent pot lining (SPL) management represents a major concern for aluminum smelters. There are two key elements for spent pot lining management: recycling and safe storage. Spent pot lining waste can potentially have beneficial uses in co-firing in cement plants. Also, safe storage of SPL is of utmost importance. Gas generation of SPL reaction with water and ignition sensitivity must be studied. However, determining the feasibility of SPL co-firing and developing the required procedures for safe storage rely on determining experimentally all the necessary SPL properties along with the appropriate test methods, recognized by emissions standards and fire safety design codes. The applicable regulations and relevant SPL properties for this purpose are presented along with the corresponding test methods.
The molecular mechanism of SPOROCYTELESS/NOZZLE in controlling Arabidopsis ovule development
Wei, Baoye; Zhang, Jinzhe; Pang, Changxu; Yu, Hao; Guo, Dongshu; Jiang, Hao; Ding, Mingxin; Chen, Zhuoyao; Tao, Qing; Gu, Hongya; Qu, Li-Jia; Qin, Genji
2015-01-01
Ovules are essential for plant reproduction and develop into seeds after fertilization. SPOROCYTELESS/NOZZLE (SPL/NZZ) has been known for more than 15 years as an essential factor for ovule development in Arabidopsis, but the biochemical nature of SPL function has remained unsolved. Here, we demonstrate that SPL functions as an adaptor-like transcriptional repressor. We show that SPL recruits TOPLESS/TOPLESS-RELATED (TPL/TPR) co-repressors to inhibit the CINCINNATA (CIN)-like TEOSINTE BRANCHED1/CYCLOIDEA/PCF (TCP) transcription factors. We reveal that SPL uses its EAR motif at the C-terminal end to recruit TPL/TPRs and its N-terminal part to bind and inhibit the TCPs. We demonstrate that either disruption of TPL/TPRs or overexpression of TCPs partially phenocopies the defects of megasporogenesis in spl. Moreover, disruption of TCPs causes phenotypes that resemble spl-D gain-of-function mutants. These results define the action mechanism for SPL, which along with TPL/TPRs controls ovule development by repressing the activities of key transcription factors. Our findings suggest that a similar gene repression strategy is employed by both plants and fungi to control sporogenesis. PMID:25378179
Mao, Xinguo; Li, Ang; Wang, Jingyi; Chang, Xiaoping; Zhang, Xueyong
2017-01-01
Maintaining high and stable yields has become an increasing challenge in wheat breeding due to climate change. Although Squamosa-promoter binding protein (SBP)-box genes have important roles in plant development, very little is known about the actual biological functions of wheat SBP-box family members. Here, we dissect the functional conservation, divergence, and exploitation of homoeologs of two paralogous TaSPL wheat loci during domestication and breeding. TaSPL20 and TaSPL21 were highly expressed in the lemma and palea. Ectopic expressions of TaSPL20/21 in rice exhibited similar functions in terms of promoting panicle branching but had different functions during seed development. We characterized all six TaSPL20/21 genes located across the three homoeologous (A, B, and D) genomes. According to the functional analysis of naturally occurring variants in 20 environments, four favorable haplotypes were identified. Together, they reduced plant height by up to 27.5%, and TaSPL21-6D-HapII increased 1000-grain weight by 9.73%. Our study suggests that TaSPL20 and TaSPL21 homoeologs underwent diversification in function with each evolving its own distinctive characteristics. During domestication and breeding of wheat in China, favorable haplotypes of each set were selected and exploited to varying degrees due to their large effects on plant height and 1000-grain weight. PMID:28424214
Son, Su-Young; Lee, Joo-Young; Tochihara, Yutaka
2013-01-01
The purpose of the present study was to elucidate differences in actual work environments, mobility and satisfaction between firefighters wearing aluminized and non-aluminized personal protective equipment (PPE), and to suggest a proper standard test method for Japanese firefighters' PPE. A survey from two cities in Japan (City A: aluminized PPE; City B: non aluminized PPE) was undertaken. A total of 525 firefighters from City A and 757 from City B participated. Firefighters spent 22.5 min (City A) and 27.3 min (City B) on average firefighting with the full set of PPE in one incident, but the heat strain experienced among firefighters from City A was twice that of firefighters from City B (57.5% and 28.4%). Firefighters spent 65.9 min on one incident and 24.2 min for suppression of fire with the full set of PPE on average. The toughest task that caused physical strain in City A was 'stair climbing' and in City B was 'drawing up a hose filled with water'. The most restricted body region due to PPE was the knee for both groups. Evaluations revealed that the aluminized fire jacket had worse ventilation and mobility than the non-aluminized, while the non-aluminized one received with more unfavorable evaluations for water resistance and maintainability.
[Origin of acoustically evoked short latency negative response in guinea pigs].
Huang, Wen-qin; Qin, Huan-hua; Nong, Dong-xiao; Tang, An-zhou; Li, Zhi-mei; Yang, Tian
2011-04-01
To establish a model of acoustically evoked short latency negative response (ASNR) in guinea pigs, a model of profound hearing loss with normal saccular functions, and verify the correlation between ASNR and vestibular evoked myogenic potential (VEMP). Thirty-two healthy guinea pigs were employed in the experiment, which were randomly divided into control group (16 subjects) and deafened group (16 subjects). Each animal experienced auditory and vestibular tests including auditory brainstem response (ABR), VEMP and caloric test. A quick treatment was employed for deafened group consisting of a subcutaneous injection of kanamycin at a dose of 400 mg/kg followed by a jugular vein injection of ethacrynic acid at a dose of 40 mg/kg one hour later. The animals were received ABR, VEMP and caloric test 7 - 10 days following the drug administration. The deafened group was further divided into ASNR group and non-ASNR group, based on the presence of ASNR. In deafened group, five subjects died postoperatively, 11 subjects (22 ears) provided full data, ASNR was elicited in eight ears (36.4%), the threshold was 120 - 130 dB SPL with mean of (124.4 ± 4.96) dB SPL. Its latency range was 1.75 - 2.60 ms with mean of (2.15 ± 0.27) ms. The mean latency of threshold was (2.34 ± 0.18) ms. All eight ASNR ears presented with VEMP. The VEMP threshold, positive and negative potential latencies proved no statistical difference (P > 0.05) between ASNR group and control group. Significant difference was detected between the VEMP presence of ASNR group and non-ASNR group (P = 0.002). There was no statistically significant correlation between VEMP and caloric test neither between ASNR and caloric test in deafened group. This study evoked ASNR in an ototoxicity guinea pig model which has profound hearing loss with normal saccular functions. The presence of ASNR correlated with VEMP, however, not correlated with caloric test, suggesting that ASNR and VEMP are both originated from the saccule.
Using SPL (Spent Pot-Lining) as an Alternative Fuel in Metallurgical Furnaces
NASA Astrophysics Data System (ADS)
Gao, Lei; Mostaghel, Sina; Ray, Shamik; Chattopadyay, Kinnor
2016-09-01
Replacing coke (coal) in a metallurgical furnace with other alternative fuels is beneficial for process economics and environmental friendliness. Coal injection is a common practice in blast furnace ironmaking, and spent pot-lining (SPL) was conceptualized as an alternative to coal. SPL is a resourceful waste from primary Aluminum production, with high carbon value. Equilibrium thermodynamics was used to calculate the energy content of SPL, and the compositional changes during SPL combustion. In order to capture the kinetics and mass transfer aspects, a blast furnace tuyere region CFD model was developed. The results of SPL combustion were compared with standard PCI coals, which are commonly used in blast furnaces. The CFD model was validated with experimental results for standard high volatile coals.
Nett, Beth; Brosky, Joseph A; Velarde, Lynnuel; Pariser, David P; Boyce, David A
2010-02-01
Although it is common practice to administer pre-participation examinations (PPE) of athletes prior to training, there are no clearly established formats. Elements integral to the PPE fall within the scope of physical therapist practice, and are often categorized as a form of primary prevention for musculoskeletal disorders as defined in the Guide to Physical Therapist Practice. The purpose of this study is to describe the design and implementation of a PPE for a women's professional (gridiron) football team. The results and findings from this PPE provide one of the first musculoskeletal profiles and information about selected physical characteristics from members of a female professional football team. Players from the Kentucky Karma women's football team, a member of the National Women's Football League (NWFA), volunteered to participate in a PPE. Of twenty-five eligible team members, thirteen consented to participate. The PPE consisted of a health history questionnaire, a musculoskeletal screening, and a series of physical performance and agility tests. The players' average (± SD) age, height, weight, body mass index (BMI), and body fat percentage were 29.6 (± 5.6) yrs., 1.66 (± .05) m, 66.8 (± 12.6) kg, 24.1 (± 3.7), and 27.4 (± 6.6) %, respectively. Commonly reported injuries were similar to those reported in men's collegiate football. This is one of the first papers to report on a model PPE for a women's professional football team. Future research is needed to establish a standard PPE, recognize common injuries, and develop prevention strategies unique to women's professional football.
O'Brien, Catherine; Blanchard, Laurie A; Cadarette, Bruce S; Endrusick, Thomas L; Xu, Xiaojiang; Berglund, Larry G; Sawka, Michael N; Hoyt, Reed W
2011-10-01
Personal protective equipment (PPE) refers to clothing and equipment designed to protect individuals from chemical, biological, radiological, nuclear, and explosive hazards. The materials used to provide this protection may exacerbate thermal strain by limiting heat and water vapor transfer. Any new PPE must therefore be evaluated to ensure that it poses no greater thermal strain than the current standard for the same level of hazard protection. This review describes how such evaluations are typically conducted. Comprehensive evaluation of PPE begins with a biophysical assessment of materials using a guarded hot plate to determine the thermal characteristics (thermal resistance and water vapor permeability). These characteristics are then evaluated on a thermal manikin wearing the PPE, since thermal properties may change once the materials have been constructed into a garment. These data may be used in biomedical models to predict thermal strain under a variety of environmental and work conditions. When the biophysical data indicate that the evaporative resistance (ratio of permeability to insulation) is significantly better than the current standard, the PPE is evaluated through human testing in controlled laboratory conditions appropriate for the conditions under which the PPE would be used if fielded. Data from each phase of PPE evaluation are used in predictive models to determine user guidelines, such as maximal work time, work/rest cycles, and fluid intake requirements. By considering thermal stress early in the development process, health hazards related to temperature extremes can be mitigated while maintaining or improving the effectiveness of the PPE for protection from external hazards.
Quality of care and investment in property, plant, and equipment in hospitals.
Levitt, S W
1994-01-01
OBJECTIVE. This study explores the relationship between quality of care and investment in property, plant, and equipment (PPE) in hospitals. DATA SOURCES. Hospitals' investment in PPE was derived from audited financial statements for the fiscal years 1984-1989. Peer Review Organization (PRO) Generic Quality Screen (GQS) reviews and confirmed failures between April 1989 and September 1990 were obtained from the Massachusetts PRO. STUDY DESIGN. Weighted least squares regression models used PRO GQS confirmed failure rates as the dependent variable, and investment in PPE as the key explanatory variable. DATA EXTRACTION. Investment in PPE was standardized, summed by the hospital over the six years, and divided by the hospital's average number of beds in that period. The number of PRO reviewed cases with one or more GQS confirmed failures was divided by the total number of cases reviewed to create confirmed failure rates. PRINCIPAL FINDINGS. Investment in PPE in Massachusetts hospitals is correlated with GQS confirmed failure rates. CONCLUSIONS. A financial variable, investment in PPE, predicts certain dimensions of quality of care in hospitals. PMID:8113054
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glasser, S.W.; Korfhagen, T.R.; Weaver, T.E.
1988-01-05
In hyaline membrane disease of premature infants, lack of surfactant leads to pulmonary atelectasis and respiratory distress. Hydrophobic surfactant proteins of M/sub r/ = 5000-14,000 have been isolated from mammalian surfactants which enhance the rate of spreading and the surface tension lowering properties of phospholipids during dynamic compression. The authors have characterized the amino-terminal amino acid sequence of pulmonary proteolipids from ether/ethanol extracts of bovine, canine, and human surfactant. Two distinct peptides were identified and termed SPL(pVal) and SPL(Phe). An oligonucleotide probe based on the valine-rich amino-terminal amino acid sequence of SPL(pVal) was utilized to isolate cDNA and genomic DNAmore » encoding the human protein, termed surfactant proteolipid SPL(pVal) on the basis of its unique polyvaline domain. The primary structure of a precursor protein of 20,870 daltons, containing the SPL(pVal) peptide, was deduced from the nucleotide sequence of the cDNAs. Hybrid-arrested translation and immunoprecipitation of labeled translation products of human mRNA demonstrated a precursor protein, the active hydrophobic peptide being produced by proteolytic processing. Two classes of cDNAs encoding SPL(pVal) were identified. Human SPL(pVal) mRNA was more abundant in the adult than in fetal lung. The SPL(pVal) gene locus was assigned to chromosome 8.« less
Risk by use of hearing protectors--expert programme supports SMEs in appropriate selection and use.
Liedtke, M
2005-01-01
Comprehensive protection by use of PPE against the hazards at work requires more than proper selection based on the protection level needed: The PPE user directive (Council Directive 89/656/EEC, Official Journal of the European Communities L 393, 30/12/1989 p.0018 - 0028) requires an assessment of personal protective equipment itself, which has to consider the risks which may be introduced by use of PPE or use of combinations of PPE. As an example risks which may be introduced by use of hearing protectors are described. Assistance in the assessment required by PPE user directive (Council Directive 89/656/EEC, Official Journal of the European Communities L 393, 30/12/1989 p. 0018 - 0028) and in selection and use of hearing protectors with regard to this assessment is presented.
Development and psychometric evaluation of the Professional Practice Environment (PPE) scale.
Erickson, Jeanette Ives; Duffy, Mary E; Gibbons, M Patricia; Fitzmaurice, Joan; Ditomassi, Marianne; Jones, Dorothy
2004-01-01
To describe the Professional Practice Environment (PPE) scale, its conceptual development and psychometric evaluation, and its uses in measuring eight characteristics of the professional practice environment in an acute care setting. The 38-item PPE Scale was validated on a sample of 849 professional practice staff at the Massachusetts General Hospital in Boston. Psychometric analysis included: item analysis, principal components analysis (PCA) with varimax rotation and Kaiser normalization, and internal consistency reliability using Cronbach's alpha coefficient. Eight components were shown, confirming the original conceptually derived model's structure and accounting for 61% of explained variance. Cronbach's alpha coefficients for the eight PPE subscales ranged from .78 to .88. Findings showed the 38-item PPE Scale was reliable and valid for use in health outcomes research to examine the professional practice environment of staff working in acute care settings.
Center for Macromolecular Crystallography, University of Alabama in Birmingham
NASA Technical Reports Server (NTRS)
Navia, Manuel A.
1991-01-01
Porcine pancreatic elastase (PPE) crystals grown under microgravity conditions on mission STS-26 of the Space Shuttle Discovery were shown to diffract to considerably higher resolution than the best PPE crystals grown by us on the ground. We have now independently refined both the microgravity and ground-based data. Preliminary results of these refinements are summarized. These results show nearly a doubling of experimental diffraction data for this structure, exceeding 1.3 A resolution. Improved phase information derived from the refined structure of PPE based on this microgravity data has allowed us to interpret previously-uninterpretable electron density obtained from ground-based crystals of a complex of PPE with a chemically-reactive inhibitor. Intermediate stages in the enzyme-inhibitor reaction mechanism in the crystal can now be directly observed. Further refinement of PPE structures is in progress.
NASA Astrophysics Data System (ADS)
Lin, Chundan; Xia, Qide; Li, Kuan; Li, Juan; Yang, Zhenqing
2018-06-01
The ultrafast injection of excited electrons in dye/TiO2 system plays a critical role, which determines the device's efficiency in large part. In this work, we studied the geometrical structures and electronic properties of a dye/TiO2 composite system for dye-sensitized solar cells (DSSCs) by using density functional theory, and we analyzed the mechanism of ultrafast electron injection with emphasis on the power conversion efficiency. The results show that the dye SPL103/TiO2 (101) surface is more stable than dye SPL101. The electron injection driving force of SPL103/TiO2 (101) is 3.55 times that of SPL101, indicating that SPL103/TiO2 (101) has a strong ability to transfer electrons. SPL103 and SPL101/TiO2 (101) both have fast electron transfer processes, and especially the electron injection time of SPL103/TiO2 (101) is only 1.875 fs. The results of this work are expected to provide a new understanding of the mechanism of electron injection in dyes/TiO2 systems for use in highly effective DSSCs.
Chang, Melinda Y; Velez, Federico G; Demer, Joseph L; Bonelli, Laura; Quiros, Peter A; Arnold, Anthony C; Sadun, Alfredo A; Pineles, Stacy L
2017-12-01
To identify the most accurate diagnostic imaging modality for classifying pediatric eyes as papilledema (PE) or pseudopapilledema (PPE). Prospective observational study. Nineteen children between the ages of 5 and 18 years were recruited. Five children (10 eyes) with PE, 11 children (19 eyes) with PPE owing to suspected buried optic disc drusen (ODD), and 3 children (6 eyes) with PPE owing to superficial ODD were included. All subjects underwent imaging with B-scan ultrasonography, fundus photography, autofluorescence, fluorescein angiography (FA), optical coherence tomography (OCT) of the retinal nerve fiber layer (RNFL), and volumetric OCT scans through the optic nerve head with standard spectral-domain (SD OCT) and enhanced depth imaging (EDI OCT) settings. Images were read by 3 masked neuro-ophthalmologists, and the final image interpretation was based on 2 of 3 reads. Image interpretations were compared with clinical diagnosis to calculate accuracy and misinterpretation rates of each imaging modality. Accuracy of each imaging technique for classifying eyes as PE or PPE, and misinterpretation rates of each imaging modality for PE and PPE. Fluorescein angiography had the highest accuracy (97%, 34 of 35 eyes, 95% confidence interval 92%-100%) for classifying an eye as PE or PPE. FA of eyes with PE showed leakage of the optic nerve, whereas eyes with suspected buried ODD demonstrated no hyperfluorescence, and eyes with superficial ODD showed nodular staining. Other modalities had substantial likelihood (30%-70%) of misinterpretation of PE as PPE. The best imaging technique for correctly classifying pediatric eyes as PPE or PE is FA. Other imaging modalities, if used in isolation, are more likely to lead to misinterpretation of PE as PPE, which could potentially result in failure to identify a life-threatening disorder causing elevated intracranial pressure and papilledema. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Species-specificity of equine and porcine Lawsonia intracellularis isolates in laboratory animals
Sampieri, Francesca; Vannucci, Fabio A.; Allen, Andrew L.; Pusterla, Nicola; Antonopoulos, Aphroditi J.; Ball, Katherine R.; Thompson, Julie; Dowling, Patricia M.; Hamilton, Don L.; Gebhart, Connie J.
2013-01-01
Lawsonia intracellularis infection causes proliferative enteropathy (PE) in many mammalian species, with porcine and equine proliferative enteropathy (PPE and EPE) known worldwide. Hamsters are a well-published animal model for PPE infection studies in pigs. There is no laboratory animal model for EPE infection studies and it is not known whether there is species-specificity for equine or porcine isolates of L. intracellularis in animal models. The objective of this study was to determine whether it is possible to generate typical EPE lesions in hamsters after inoculation with an equine strain of L. intracellularis (EPE strain) and whether it is comparatively possible to generate PPE lesions in rabbits after inoculation with a porcine strain of L. intracellularis (PPE strain). In 2 separate trials, 4-week-old and 3-week-old weanling golden Syrian hamsters were challenged with EPE strains and compared to uninfected (both trials) and PPE-infected controls (Trial 2 only). Concurrently, 6 female New Zealand white juvenile rabbits were infected with PPE strain and observed concomitantly to 8 similar rabbits infected with EPE strain for a different experiment. Hamsters and rabbits were observed for 21 to 24 days post-infection (DPI), depending on the experiment. Neither infected species developed clinical signs. The presence of disease was assessed with diagnostic techniques classically used for pigs and horses: immune-peroxidase monolayer assay on sera; quantitative polymerase chain reaction (qPCR) detection of molecular DNA in feces; and hematoxylin and eosin (H&E) stain and immunohistochemistry (IHC) on intestinal tissues. Our results showed that EPE-challenged hamsters do not develop infection when compared with PPE controls (IHC, P = 0.009; qPCR, P = 0.0003). Conversely, PPE-challenged rabbits do not develop typical intestinal lesions in comparison to EPE-challenged rabbits, with serological response at 14 DPI being significantly lower (P = 0.0023). In conclusion, PPE and EPE strains appear to have different host-specificities for hamsters and rabbits, respectively. PMID:24124268
Northington, William E; Suyama, Joe; Goss, Fredric L; Randall, Colby; Gallagher, Michael; Hostler, David
2007-01-01
As the likelihood of terrorist acts increases, prehospital personnel have been forced to train in the proper use of chemical-resistant personal protective equipment (PPE). This protective ensemble has been reported to be physiologically taxing for the wearer, imposing an additional thermal load resulting in hypohydration, hyperthermia, and reduced work time. Victim extrication, the rescue-the-rescuer role of the rapid intervention team and rapid self-extrication, typically requires high-intensity work that can be maintained only for short time intervals. The additional physiological burden imparted by the level C PPE during high-intensity work is unknown. We hypothesized that the added thermal burden resulting from work in PPE would shorten work time and result in a higher core temperature during incremental treadmill exercise. In this prospective, crossover, laboratory study, EMS providers (n = 8, 5 male) completed a Bruce treadmill test on two occasions: once in a chemical-resistant coverall and air-purifying respirator (PPE) and once in shorts and t-shirt (CON). Oxygen consumption, vital signs, core and skin temperature, and perceptual measures of exertion, thermal sensation, and comfort were monitored throughout the test. Subjects achieved maximal oxygen consumption and more than 90% of age-predicted maximum heart rate in both conditions. Heart rate, skin temperature, and measures of perceived exertion, comfort, and thermal sensation increased during the treadmill exercise but did not differ between the PPE and CON conditions. Core temperature increased in both the CON and PPE conditions (0.8 +/- 0.5 vs. 0.7 +/- 0.3, p = 0.40). High-intensity work in level C PPE is primarily limited by cardiovascular capacity. The thermal burden associated with this short bout of work in PPE (approximately 10 minutes) is not different than high-intensity work in short pants and cotton t-shirt. Consideration should be given to cardiorespiratory fitness when assigning providers to work in chemical-resistant PPE, especially on tasks that require high-intensity work.
Damalas, Christos A; Abdollahzadeh, Gholamhossein
2016-11-15
Understanding factors affecting the use of personal protective equipment (PPE) during handling of plant protection products (PPPs) is of major importance for the design of tailored interventions to minimize exposure among farmers. However, data regarding this issue are highly limited. Factors related to the use of PPE during handling of PPPs were explored in a survey of cotton farmers in northern Greece. Data were collected through face-to-face interviews with the farmers based on a questionnaire with structured items on the frequency of use of various personal protective devices during handling of PPPs. New evidence on patterns of PPE use and potential exposure of farmers to PPPs is provided. Most farmers (49.3%) showed potentially unsafe behaviour with respect to PPE use. Hat and boots were the most commonly used protective items during PPPs use, but most of the farmers surveyed reported low frequency of use for gloves, goggles, face mask, coveralls, and respirator. Especially the respirator was reported to be the least used PPE item amongst farmers. Farmers who perceived PPPs as harmful substances or those who had an episode of intoxication in the past reported more frequent use of several PPE items. Stepwise multiple regression analysis revealed that the variable episode of intoxication in the past exerted the strongest positive influence on PPE use, followed by the perception of PPPs being hazardous substances, upper secondary education, previous training on PPPs (i.e., spraying equipment, application parameters, risks to human health and environment, safety issues) and farm size under cultivation. Old age exerted a significant negative influence on PPE use, namely, elderly farmers tended not to use PPE. Strategies to maximize the protection of applicators of PPPs from hazardous exposures still require innovation to achieve increased effectiveness. Emphasis on lifelong training and education of farmers about hazards and risks of PPPs is crucial for changing wrong behaviours in handling of PPPs. Copyright © 2016 Elsevier B.V. All rights reserved.
Role of a Transcriptional Regulator in Programmed Cell Death and Plant Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Julie M. Stone
2008-09-13
The long-term goal of this research is to understand the role(s) and molecular mechanisms of programmed cell death (PCD) in the controlling plant growth, development and responses to biotic and abiotic stress. We developed a genetic selection scheme to identify A. thaliana FB1-resistant (fbr) mutants as a way to find genes involved in PCD (Stone et al., 2000; Stone et al., 2005; Khan and Stone, 2008). The disrupted gene in fbr6 (AtSPL14) responsible for the FB1-insensitivity and plant architecture phenotypes encodes a plant-specific SBP DNA-binding domain transcriptional regulator (Stone et al., 2005; Liang et al., 2008). This research plan ismore » designed to fill gaps in the knowledge about the role of SPL14 in plant growth and development. The work is being guided by three objectives aimed at determining the pathways in which SPL14 functions to modulate PCD and/or plant development: (1) determine how SPL14 functions in plant development, (2) identify target genes that are directly regulated by SPL14, and (3) identify SPL14 modifications and interacting proteins. We made significant progress during the funding period. Briefly, some major accomplishments are highlighted below: (1) To identify potential AtSPL14 target genes, we identified a consensus DNA binding site for the AtSPL14 SBP DNA-binding domain using systematic evolution of ligands by exponential selection (SELEX) and site-directed mutagenesis (Liang et al., 2008). This consensus binding site was used to analyze Affymetrix microarray gene expression data obtained from wild-type and fbr6 mutant plants to find possible AtSPL14-regulated genes. These candidate AtSPL14-regulated genes are providing new information on the molecular mechanisms linking plant PCD and plant development through modulation of the 26S proteasome. (2) Transgenic plants expressing epitope-tagged versions of AtSPL14 are being used to confirm the AtSPL14 targets (by ChIP-PCR) and further dissect the molecular interactions (Nazarenus, Liang and Stone, in preparation) (3) Double mutants generated between fbr6 and various accelerated cell death (acd) mutants indicate that sphingolipid metabolism is influenced by AtSPL14 and sphingolipidomics profiling supports this conclusion (Lin, Markham and Stone, in preparation). (4) A new set of phenotypes have been uncovered in the original fbr6-1 mutant, including a short-root phenotype related to auxin signaling and altered photosynthetic parameters related to stomatal density and conductance (Lin and Stone, in preparation; Lin, Madhavan and Stone, in preparation). Additional AtSPL14-related mutants and transgenic plants have been generated to effectively dissect the functions of AtSPL14, including a dominant negative fbr6-2 allele and transgenic plants overexpressing FBR6/AtSPL14 that display an accelerated cell death (acd) phenotype.« less
Mutations in ppe38 block PE_PGRS secretion and increase virulence of Mycobacterium tuberculosis.
Ates, Louis S; Dippenaar, Anzaan; Ummels, Roy; Piersma, Sander R; van der Woude, Aniek D; van der Kuij, Kim; Le Chevalier, Fabien; Mata-Espinosa, Dulce; Barrios-Payán, Jorge; Marquina-Castillo, Brenda; Guapillo, Carolina; Jiménez, Connie R; Pain, Arnab; Houben, Edith N G; Warren, Robin M; Brosch, Roland; Hernández-Pando, Rogelio; Bitter, Wilbert
2018-02-01
Mycobacterium tuberculosis requires a large number of secreted and exported proteins for its virulence, immune modulation and nutrient uptake. Most of these proteins are transported by the different type VII secretion systems 1,2 . The most recently evolved type VII secretion system, ESX-5, secretes dozens of substrates belonging to the PE and PPE families, which are named for conserved proline and glutamic acid residues close to the amino terminus 3,4 . However, the role of these proteins remains largely elusive 1 . Here, we show that mutations of ppe38 completely block the secretion of two large subsets of ESX-5 substrates, that is, PPE-MPTR and PE_PGRS, together comprising >80 proteins. Importantly, hypervirulent clinical M. tuberculosis strains of the Beijing lineage have such a mutation and a concomitant loss of secretion 5 . Restoration of PPE38-dependent secretion partially reverted the hypervirulence phenotype of a Beijing strain, and deletion of ppe38 in moderately virulent M. tuberculosis increased virulence. This indicates that these ESX-5 substrates have an important role in virulence attenuation. Phylogenetic analysis revealed that deletion of ppe38 occurred at the branching point of the 'modern' Beijing sublineage and is shared by Beijing outbreak strains worldwide, suggesting that this deletion may have contributed to their success and global distribution 6,7 .
Gao, Ruimin; Austin, Ryan S; Amyot, Lisa; Hannoufa, Abdelali
2016-08-19
Medicago sativa (alfalfa) is a low-input forage and potential bioenergy crop, and improving its yield and quality has always been a focus of the alfalfa breeding industry. Transgenic alfalfa plants overexpressing a precursor of alfalfa microRNA156 (MsmiR156) were recently generated by our group. These plants (miR156OE) showed enhanced biomass yield, reduced internodal length, increased shoot branching and trichome density, and a delay in flowering time. Transcripts of three SQUAMOSA-PROMOTER BINDING PROTEIN-LIKE (SPL) genes (MsSPL6, MsSPL12, and MsSPL13) were found to be targeted for cleavage by MsmiR156 in alfalfa. To further illustrate the molecular mechanisms underlying the effects of miR156 in alfalfa, two miR156OE genotypes (A11a and A17) were subjected to Next Generation RNA Sequencing with Illumina HiSeq. More than 1.11 billion clean reads were obtained from our available sequenced samples. A total of 160,472 transcripts were generated using Trinity de novo assembly and 4,985 significantly differentially expressed genes were detected in miR156OE plants A11a and A17 using the Medicago truncatula genome as reference. A total of 17 genes (including upregulated, downregulated, and unchanged) were selected for quantitative real-time PCR (qRT-PCR) validation, which showed that gene expression levels were largely consistent between qRT-PCR and RNA-Seq data. In addition to the established SPL genes MsSPL6, MsSPL12 and MsSPL13, four new SPLs; MsSPL2, MsSPL3, MsSPL4 and MsSPL9 were also down-regulated significantly in both miR156OE plants. These seven SPL genes belong to genes phylogeny clades VI, IV, VIII, V and VII, which have been reported to be targeted by miR156 in Arabidopsis thaliana. The gene ontology terms characterized electron transporter, starch synthase activity, sucrose transport, sucrose-phosphate synthase activity, chitin binding, sexual reproduction, flavonoid biosynthesis and lignin catabolism correlate well to the phenotypes of miR156OE alfalfa plants. This is the first report of changes in global gene expression in response to miR156 overexpression in alfalfa. The discovered miR156-targeted SPL genes belonging to different clades indicate miR156 plays fundamental and multifunctional roles in regulating alfalfa plant development.
Kuhn, Pierre; Zores, Claire; Pebayle, Thierry; Hoeft, Alain; Langlet, Claire; Escande, Benoît; Astruc, Dominique; Dufour, André
2012-04-01
Very early preterm infants (VPIs) are exposed to unpredictable noise in neonatal intensive care units. Their ability to perceive moderate acoustic environmental changes has not been fully investigated. Physiological values of the 598 isolated sound peaks (SPs) that were 5-10 and 10-15 dB slow-response A (dBA) above background noise levels and that occurred during infants' sleep varied significantly, indicating that VPIs detect them. Exposure to 10-15 dBA SPs during active sleep significantly increased mean heart rate and decreased mean respiratory rate and mean systemic and cerebral oxygen saturations relative to baseline. VPIs are sensitive to changes in their nosocomial acoustic environment, with a minimal signal-to-noise ratio (SNR) threshold of 5-10 dBA. These acoustic changes can alter their well-being. In this observational study, we evaluated their differential auditory sensitivity to sound-pressure level (SPL) increments below 70-75 dBA equivalent continuous level in their incubators. Environmental (SPL and audio recording), physiological, cerebral, and behavioral data were prospectively collected over 10 h in 26 VPIs (GA 28 (26-31) wk). SPs emerging from background noise levels were identified and newborns' arousal states at the time of SPs were determined. Changes in parameters were compared over 5-s periods between baseline and the 40 s following the SPs depending on their SNR thresholds above background noise.
The characteristics of salivary pepsin in patients with severe motor and intellectual disabilities.
Hashizume, Naoki; Fukahori, Suguru; Asagiri, Kimio; Ishii, Shinji; Saikusa, Nobuyuki; Higashidate, Naruki; Yoshida, Motomu; Masui, Daisuke; Sakamoto, Saki; Tanaka, Yoshiaki; Yagi, Minoru; Yamashita, Yushiro
2017-09-01
The aim of the present study was to determine the utility of measuring the salivary pepsin level (SPL) as an objective assessment of gastroesophageal reflux disease (GERD) in severe motor and intellectual disabilities (SMID) patients. This prospective study included 26 SMID patients who underwent simultaneous 24-h multichannel intraluminal impedance pH measurement (pH/MII) and SPL evaluation. The enrolled patients were divided into GERD (+) or GERD (-) groups according to the pH/MII findings. The age, gender and pH/MII parameters were compared between the two groups. A correlation analysis was also conducted for the SPL following early-morning fasting and post-enteral feeding and the age, gender, presence of gastrostomy and tracheostomy and pH/MII parameters. The SPL was compared between the two sampling groups. Fifteen patients were classified as GERD (+), and 11 patients were classified as GERD (-). The mean SPL following early-morning fasting and post-enteral feeding among all patients were 104.3 (median: 38, 25th and 75th percentile: 12, 361) ng/ml and 222.2 (median: 152:0, 500) ng/ml, respectively. Regarding positivity, 76.9% and 73.1% of SPL values in early-morning fasting and post-enteral feeding SMID patients, respectively, were positive (≧16ng/ml). The SPL following early-morning fasting demonstrated a weak but significant positive correlation with age. In contrast, we noted no correlation between the pH/MII parameters and the SPL for either the early-morning fasting or post-enteral feeding patients, and no significant difference in the SPL was observed between the GERD (+) and (-) patients. The present study showed that a high proportion of SMID patients had a relatively high SPL, regardless of the presence of GERD. The SPL in SMID patients might be affected by several distinctive factors in addition to gastroesophageal reflux. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Yadav, Mukesh Kumar; Choi, June; Song, Jae-Jun
2014-03-01
Gentamicin (GM) is a commonly used aminoglycoside antibiotic that generates free oxygen radicals within the inner ear, which can cause vestibulo-cochlear toxicity and permanent damage to the sensory hair cells and neurons. Piper longum L. (PL) is a well-known spice and traditional medicine in Asia and Pacific islands, which has been reported to exhibit a wide spectrum of activity, including antioxidant activity. In this study, we evaluated the effect of hexane:ethanol (2:8) PL extract (subfraction of PL [SPL] extract) on GM-induced hair cell loss in basal, middle and apical regions in a neonatal cochlea cultures. The protective effects of SPL extract were measured by phalloidin staining of cultures from postnatal day 2-3 mice with GM-induced hair cell loss. The anti-apoptosis activity of SPL extract was measured using double labeling by terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) and myosin-7a staining. The radical-scavenging activity of SPL extract was assessed using the 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. SPL extract at a concentration of 1 µg/mL significantly inhibited GM-induced hair cell loss at basal and middle region of cochlea, while 5 µg/mL was effective against apical region hair cell loss. The protective effect of SPL extract was concentration dependent and hair cells retained their stereocilia in explants treated with SPL extract prior to treatment with 0.3 mM GM. SPL extract decreased GM-induced apoptosis of hair cells as assessed by TUNEL staining. The outer hair and inner hair counts were not decreased in SPL extract treated groups in compare to GM treated explants. Additionally, SPL extract showed concentration dependent radical scavenging activity in a DPPH assay. An anti-apoptosis effect and potent radical scavenger activity of SPL extract protects from GM-induced hair cell loss at basal, middle and apical regions in neonatal cochlea cultures.
Kim, Jae Joon; Lee, Jeong Hwan; Kim, Wanhui; Jung, Hye Seung; Huijser, Peter; Ahn, Ji Hoon
2012-01-01
The flowering time of plants is affected by modest changes in ambient temperature. However, little is known about the regulation of ambient temperature-responsive flowering by small RNAs. In this study, we show that the microRNA156 (miR156)-SQUAMOSA PROMOTER BINDING PROTEIN-LIKE3 (SPL3) module directly regulates FLOWERING LOCUS T (FT) expression in the leaf to control ambient temperature-responsive flowering. Overexpression of miR156 led to more delayed flowering at a lower ambient temperature (16°C), which was associated with down-regulation of FT and FRUITFULL expression. Among miR156 target genes, SPL3 mRNA levels were mainly reduced, probably because miR156-mediated cleavage of SPL3 mRNA was higher at 16°C. Overexpression of miR156-resistant SPL3 [SPL3(−)] caused early flowering, regardless of the ambient temperature, which was associated with up-regulation of FT and FRUITFULL expression. Reduction of miR156 activity by target mimicry led to a phenotype similar to that of SUC2::rSPL3 plants. FT up-regulation was observed after dexamethasone treatment in GVG-rSPL3 plants. Misexpression and artificial microRNA-mediated suppression of FT in the leaf dramatically altered the ambient temperature-responsive flowering of plants overexpressing miR156 and SPL3(−). Chromatin immunoprecipitation assay showed that the SPL3 protein directly binds to GTAC motifs within the FT promoter. Lesions in TERMINAL FLOWER1, SHORT VEGETATIVE PHASE, and EARLY FLOWERING3 did not alter the expression of miR156 and SPL3. Taken together, our data suggest that the interaction between the miR156-SPL3 module and FT is part of the regulatory mechanism controlling flowering time in response to ambient temperature. PMID:22427344
Reif, Roberto; Zhi, Zhongwei; Dziennis, Suzan; Nuttall, Alfred L; Wang, Ruikang K
2013-10-01
In this work we determined the contributions of loud sound exposure (LSE) on cochlear blood flow (CoBF) in an in vivo anesthetized mouse model. A broadband noise system (20 kHz bandwidth) with an intensity of 119 dB SPL, was used for a period of one hour to produce a loud sound stimulus. Two techniques were used to study the changes in blood flow, a Doppler optical microangiography (DOMAG) system; which can measure the blood flow within individual cochlear vessels, and a laser Doppler flowmetry (LDF) system; which averages the blood flow within a volume (a hemisphere of ~1.5 mm radius) of tissue. Both systems determined that the blood flow within the cochlea is reduced due to the LSE stimulation.
Alleviation of mortality induced by salicylate and stress.
Jastreboff, P J; Brennan, J F
1994-05-15
Protection from the deleterious effects of the interaction of environmental stress and salicylate by calcium supplement was investigated in 96 pigmented rats. Within a 2 x 2 x 4 factorial design, rats were assigned to groups defined by: A) ad lib access to 1) plain tap water, or 2) 50 mM calcium chloride solution; B) exposure to stressors consisting of daily 10 h periods of 1) 98 dB SPL noise, or 2) confinement precluding movements; C) daily injections of 233, 350, or 410 mg/kg of sodium salicylate or the saline vehicle. For subjects maintained on tap water, weight loss and mortality increased with salicylate levels, with all subjects dying in the group drinking water and injected with 410 mg/kg. Calcium protected all of the subjects in the noise stress group but not in the confined group.
He, Chao; Wang, Bo; Li, Danni; Xu, Huan; Shen, Yongchun
2017-08-01
Parapneumonic pleural effusion (PPE) is a common complication of pneumonia. The accurate diagnosis of PPE remains a challenge. Recent studies suggest that procalcitonin (PCT) emerges as a potential biomarker for PPE. Our study aimed to determine the diagnostic value of PCT for PPE by a clinical study and summarize the overall diagnostic performance of PCT through a meta-analysis. Demographic and clinical data of the patients with PPE and controls were collected in our clinical study. The diagnostic performances of serum PCT (s-PCT) were analyzed via receiver operating characteristic (ROC) curve analysis, using area under the curve (AUC) as a measure of accuracy. Literature databases were systematically searched for the studies examining the accuracy of PCT for diagnosing PPE. Data on sensitivity, specificity, positive/negative likelihood ratio (PLR/NLR), and diagnostic odds ratio (DOR) were pooled. Summary ROC curves and AUC were used to evaluate overall test performance. In our clinical study, 47 patients with PPE and 101 controls were included. The s-PCT levels were significantly increased in the setting of PPE (5.44 ± 9.82 ng/mL) compared with malignant PE (0.15 ± 0.19 ng/mL), tuberculous PE (0.18 ± 0.16 ng/mL), and transudates (0.09 ± 0.03 ng/mL) (P < .001). Using a cutoff value of 0.195 ng/mL, the sensitivity and specificity of s-PCT in diagnosing PPE were 0.83 and 0.80, respectively, and AUC was 0.89. In addition, 11 studies were included in our meta-analysis. Summary performance estimates for s-PCT in diagnosing PPE were as follows: sensitivity, 0.78 (95% CI: 0.71-0.84); specificity, 0.74 (95% CI: 0.69-0.78); PLR, 3.46 (95% CI: 2.09-5.74); NLR, 0.27 (95% CI: 0.14-0.54); DOR, 12.37 (95% CI: 4.34-41.17); and AUC, 0.84. The corresponding estimates for p-PCT were as follows: sensitivity, 0.62 (95% CI: 0.57-0.67); specificity, 0.71 (95% CI: 0.68-0.75); PLR 2.31 (95% CI: 1.81-2.95); NLR, 0.47 (95% CI: 0.35-0.63); DOR, 5.48 (95% CI: 3.07-9.77); and AUC, 0.80. Both s-PCT and p-PCT might have modest performance in diagnosing PPE. However, more studies on a large scale should be performed to confirm our findings.
Torp, Steffen; Grøgaard, Jens B; Moen, Bente E; Bråtveit, Magne
2005-08-01
On the basis of the job demands-control-support model by Karasek and Theorell, we investigated how social and organizational factors influence workers' use of personal protective equipment (PPE). A cross-sectional study was performed among 1420 workers in 203 motor vehicle-repair garages. Multilevel modeling was performed to account for the hierarchical structure of the data. Social and management support correlated positively with PPE use at the worker level. Low demands measured at the garage level and having a health and safety management system at the garage also correlated with active use of PPE. An interaction effect between social support and garage-level demands was observed. In addition to health information and provision of PPE, focusing on social and organizational factors seems necessary to get more workers to comply with the instructions on PPE use.
New PPE Policy Will Help Prevent Injuries | Poster
By Ashley Shoemaker, Guest Writer In January 2013, a revised policy on personal protective equipment (PPE) was approved for all government and contractor employees at NCI at Frederick. This new policy was driven by a high number of eye injuries at NCI at Frederick (56 between 2007 and 2012) that were directly related to inadequate PPE. The Occupational Safety and Health Act
Parkia pendula lectin as histochemistry marker for meningothelial tumour.
Beltrão, E I C; Medeiros, P L; Rodrigues, O G; Figueredo-Silva, J; Valença, M M; Coelho, L C B B; Carvalho, L B
2003-01-01
Lectins have been intensively used in histochemical techniques for cell surface characterization. These proteins are involved in several biological processes and their use as histochemical markers have been evaluated since they can indicate differences in cell surfaces. Parkia pendula lectin (PpeL) was evaluated as histochemical marker for meningothelial meningioma biopsies. Tissue slices were incubated with PpeL conjugated to horseradish peroxidase (PpeL-HRP) and Concanavalin A-HRP (ConA-HPR) and the binding visualized with diaminobenzidine and hydrogen peroxide. The lectin-tissue binding was inhibited with D-glucose. PpeL showed to be a useful tool for the characterization of meningothelial tumour and clinico-pathological diagnosis.
Arcury, Thomas A; Grzywacz, Joseph G; Anderson, Andrea M; Mora, Dana C; Carrillo, Lourdes; Chen, Haiying; Quandt, Sara A
2013-02-01
This analysis describes the work safety climate of Latino poultry processing workers and notes differences by worker personal characteristics and employer; describes the use of common personal protective equipment (PPE) among workers; and examines the associations of work safety climate with use of common PPE. Data are from a cross-sectional study of 403 Latino poultry processing workers in western North Carolina. Work safety climate differed little by personal characteristics, but it did differ consistently by employer. Provision of PPE varied; for example, 27.2% of participants were provide with eye protection at no cost, 57.0% were provided with hand protection at no cost, and 84.7% were provided with protective clothing at no cost. PPE use varied by type. Provision of PPE at no cost was associated with lower work safety climate; this result was counter-intuitive. Consistent use of PPE was associated with higher work safety climate. Work safety climate is important for improving workplace safety for immigrant workers. Research among immigrant workers should document work safety climate for different employers and industries, and delineate how work safety climate affects safety behavior and injuries. Copyright © 2012 Wiley Periodicals, Inc.
Norris, Emma; Myers, Lynn
2013-11-01
Despite evident protective value of motorcycle personal protective equipment (PPE), no research has assessed considerations behind its uptake in UK riders. A cross-sectional online questionnaire design was employed, with riders (n=268) recruited from online motorcycle forums. Principal component analysis found four PPE behavioural outcomes. Theoretical factors of intentions, attitudes, injunctive and descriptive subjective norms, risk perceptions, anticipated regret, benefits and habit were also identified for further analysis. High motorcycle jacket, trousers and boots wear, middling high-visibility wear and low non-Personal Protective Equipment wear were found. Greater intentions, anticipated regret and perceived benefits were significantly associated with increased motorcycle jacket, trousers and boots wear, with habit presence and scooter use significantly associated with increased high-visibility wear. Lower intentions, anticipated regret and risk perceptions, being female, not holding a car licence and urban riding were significantly associated with increased non-PPE wear. A need for freedom of choice and mixed attitudes towards PPE use were evident in additional comments. PPE determinants in this sample provide a preliminary basis for future uptake interventions. Larger scale and qualitative research is needed to further investigate relevant constructs. Copyright © 2013 Elsevier Ltd. All rights reserved.
Stockpile Model of Personal Protective Equipment in Taiwan.
Chen, Yu-Ju; Chiang, Po-Jung; Cheng, Yu-Hsin; Huang, Chun-Wei; Kao, Hui-Yun; Chang, Chih-Kai; Huang, Hsun-Miao; Liu, Pei-Yin; Wang, Jen-Hsin; Chih, Yi-Chien; Chou, Shu-Mei; Yang, Chin-Hui; Chen, Chang-Hsun
The Taiwan Centers for Disease Control (Taiwan CDC) has established a 3-tier personal protective equipment (PPE) stockpiling framework that could maintain a minimum stockpile for the surge demand of PPE in the early stage of a pandemic. However, PPE stockpiling efforts must contend with increasing storage fees and expiration problems. In 2011, the Taiwan CDC initiated a stockpile replacement model in order to optimize the PPE stockpiling efficiency, ensure a minimum stockpile, use the government's limited funds more effectively, and achieve the goal of sustainable management. This stockpile replacement model employs a first-in-first-out principle in which the oldest stock in the central government stockpile is regularly replaced and replenished with the same amount of new and qualified products, ensuring the availability and maintenance of the minimum stockpiles. In addition, a joint electronic procurement platform has been established for merchandising the replaced PPE to local health authorities and medical and other institutions for their routine or epidemic use. In this article, we describe the PPE stockpile model in Taiwan, including the 3-tier stockpiling framework, the operational model, the components of the replacement system, implementation outcomes, epidemic supports, and the challenges and prospects of this model.
McLachlan, J C; White, P; Donnelly, L; Patten, D
2010-01-01
A number of studies have explored student attitudes to examining each other (peer physical examination: PPE). Differences have emerged in whether students prefer to be examined by friends or strangers. Changes have been reported in how students feel about PPE if asked before or after the PPE programme commences. RESEARCH INTENTION: Since a Grounded Theory paradigm was employed, there was no formal research hypothesis: the research intention was to explore factors which might underlie changes in student willingness to undertake PPE following familiarity with the process. Students who had completed an Examining Fellow Students Questionnaire at the beginning and end of the academic year, and who had indicated a change in willingness to participate, were invited to attend focus groups. Four focus groups were convened and transcripts were analysed for common themes. Surprisingly, students downplayed the significance of changes. Also unexpectedly, dichotomous views emerged on familiarity, with some students preferring friends for examination and others preferring strangers. Staff embarrassment also emerged as a factor inhibiting student participation. The significance of reported changes in attitudes to PPE may have been exaggerated. Proposals for increasing the willingness of students to participate in PPE are developed from the emergent themes.
Stockpile Model of Personal Protective Equipment in Taiwan
Chen, Yu-Ju; Cheng, Yu-Hsin; Huang, Chun-Wei; Kao, Hui-Yun; Chang, Chih-Kai; Huang, Hsun-Miao; Liu, Pei-Yin; Wang, Jen-Hsin; Chih, Yi-Chien; Chou, Shu-Mei; Yang, Chin-Hui; Chen, Chang-Hsun
2017-01-01
The Taiwan Centers for Disease Control (Taiwan CDC) has established a 3-tier personal protective equipment (PPE) stockpiling framework that could maintain a minimum stockpile for the surge demand of PPE in the early stage of a pandemic. However, PPE stockpiling efforts must contend with increasing storage fees and expiration problems. In 2011, the Taiwan CDC initiated a stockpile replacement model in order to optimize the PPE stockpiling efficiency, ensure a minimum stockpile, use the government's limited funds more effectively, and achieve the goal of sustainable management. This stockpile replacement model employs a first-in-first-out principle in which the oldest stock in the central government stockpile is regularly replaced and replenished with the same amount of new and qualified products, ensuring the availability and maintenance of the minimum stockpiles. In addition, a joint electronic procurement platform has been established for merchandising the replaced PPE to local health authorities and medical and other institutions for their routine or epidemic use. In this article, we describe the PPE stockpile model in Taiwan, including the 3-tier stockpiling framework, the operational model, the components of the replacement system, implementation outcomes, epidemic supports, and the challenges and prospects of this model. PMID:28418743
Normative data for penile length in Turkish newborns.
Kutlu, Alev Oğuz
2010-01-01
Local normative data for penile size will aid physicians in clinical practice. There are no studies on stretched penile length (SPL) in newborn Turkish boys. To establish normative data for SPL of newborn Turkish boys and compare these with data from different countries. 514 newborn Turkish boys, who were not small for gestational age (SGA) or premature, were included in this cross-sectional study. SPLs of the newborns were measured by the same investigator. The correlations between SPL and gestational age, weight, length, and head circumference were evaluated. The 3(rd) percentile value for SPL was found as 3.00 cm in these Turkish newborns. Positive correlations were shown between SPL and height (r=0.240, p<0.001), weight (r=0.251, p<0.001), and head circumference (r=0.235, p<0.001). Multiple linear regression analysis showed that SPL positively correlated with height and head circumference (p=0.021 and p= 0.042, respectively). This is the largest study on SPL in newborns from our country. This normative data can be used in clinical practice for defining micropenis.
Padmanabhan, Meenu S.; Ma, Shisong; Burch-Smith, Tessa M.; Czymmek, Kirk; Huijser, Peter; Dinesh-Kumar, Savithramma P.
2013-01-01
Following the recognition of pathogen-encoded effectors, plant TIR-NB-LRR immune receptors induce defense signaling by a largely unknown mechanism. We identify a novel and conserved role for the SQUAMOSA PROMOTER BINDING PROTEIN (SBP)-domain transcription factor SPL6 in enabling the activation of the defense transcriptome following its association with a nuclear-localized immune receptor. During an active immune response, the Nicotiana TIR-NB-LRR N immune receptor associates with NbSPL6 within distinct nuclear compartments. NbSPL6 is essential for the N-mediated resistance to Tobacco mosaic virus. Similarly, the presumed Arabidopsis ortholog AtSPL6 is required for the resistance mediated by the TIR-NB-LRR RPS4 against Pseudomonas syringae carrying the avrRps4 effector. Transcriptome analysis indicates that AtSPL6 positively regulates a subset of defense genes. A pathogen-activated nuclear-localized TIR-NB-LRR like N can therefore regulate defense genes through SPL6 in a mechanism analogous to the induction of MHC genes by mammalian immune receptors like CIITA and NLRC5. PMID:23516366
Bhakhri, Bhanu Kiran; Meena, Shyam Sundar; Rawat, Mayank; Datta, Vikram
2015-02-01
It is inappropriate to use universal cut-off points to interpret stretched penile length (SPL) measurements in newborns with variable body dimensions. To assess neonatal SPL on the basis of gestational maturity and anthropometric parameters at birth. A cross-sectional observational study of SPL was conducted on stable newborns at a referral teaching hospital in north India between January and June 2012. Gestational maturity, SPL and anthropometric parameters (weight, length, head circumference and foot length) were recorded within 24 hours of birth. Variation of SPL in relation to gestational age and anthropometric parameters were evaluated using multiple linear regression models. The equation using lower confidence limits of 95% confidence intervals for the correlation coefficients provides cut-off points to define a small penis. Data from 1249 newborns demonstrated that penile growth follows the pattern of increase in body dimensions in newborns. SPL can be predicted best in relation to body and foot length taken together. SPL should be interpreted in relation to anthropometric parameters in newborns, particularly body and foot length.
Experimental Evaluation of Three Designs of Electrodynamic Flexural Transducers
Eriksson, Tobias J. R.; Laws, Michael; Kang, Lei; Fan, Yichao; Ramadas, Sivaram N.; Dixon, Steve
2016-01-01
Three designs for electrodynamic flexural transducers (EDFT) for air-coupled ultrasonics are presented and compared. An all-metal housing was used for robustness, which makes the designs more suitable for industrial applications. The housing is designed such that there is a thin metal plate at the front, with a fundamental flexural vibration mode at ∼50 kHz. By using a flexural resonance mode, good coupling to the load medium was achieved without the use of matching layers. The front radiating plate is actuated electrodynamically by a spiral coil inside the transducer, which produces an induced magnetic field when an AC current is applied to it. The transducers operate without the use of piezoelectric materials, which can simplify manufacturing and prolong the lifetime of the transducers, as well as open up possibilities for high-temperature applications. The results show that different designs perform best for the generation and reception of ultrasound. All three designs produced large acoustic pressure outputs, with a recorded sound pressure level (SPL) above 120 dB at a 40 cm distance from the highest output transducer. The sensitivity of the transducers was low, however, with single shot signal-to-noise ratio (SNR)≃15 dB in transmit–receive mode, with transmitter and receiver 40 cm apart. PMID:27571075
Combined Effect of Fluid and Pressure on Middle Ear Function
Dai, Chenkai; Wood, Mark W.; Gan, Rong Z.
2008-01-01
In our previous studies, the effects of effusion and pressure on sound transmission were investigated separately. The aim of this study is to investigate the combined effect of fluid and pressure on middle ear function. An otitis media with effusion model was created by injecting saline solution and air pressure simultaneously into the middle ear of human temporal bones. Tympanic membrane displacement in response to 90 dB SPL sound input was measured by a laser vibrometer and the compliance of the middle ear was measured by a tympanometer. The movement of the tympanic membrane at the umbo was reduced up to 17 dB by the combination of fluid and pressure in the middle ear over the auditory frequency range. The fluid and pressure effects on the umbo movement in the fluid-pressure combination are not additive. The combined effect of fluid and pressure on the umbo movement is different compared with that of only fluid or pressure change in the middle ear. Negative pressure in fluid-pressure combination had more effect on middle ear function than positive pressure. Tympanometry can detect the middle ear pressure of the fluid-pressure combination. This study provides quantitative information for analysis of the combined effect of fluid and pressure on tympanic membrane movement. PMID:18162348
Effects of Exposure to the Sound from Seismic Airguns on Pallid Sturgeon and Paddlefish
Gross, Jackson A.; Carlson, Thomas J.; Skalski, John; Young, John V.; Hawkins, Anthony D.; Zeddies, David
2016-01-01
This study examined the effects of exposure to a single acoustic pulse from a seismic airgun array on caged endangered pallid sturgeon (Scaphirhynchus albus) and on paddlefish (Polyodon spathula) in Lake Sakakawea (North Dakota, USA). The experiment was designed to detect the onset of physiological responses including minor to mortal injuries. Experimental fish were held in cages as close as 1 to 3 m from the guns where peak negative sound pressure levels (Peak- SPL) reached 231 dB re 1 μPa (205 dB re 1 μPa2·s sound exposure level [SEL]). Additional cages were placed at greater distances in an attempt to develop a dose-response relationship. Treatment and control fish were then monitored for seven days, euthanized, and necropsied to determine injuries. Necropsy results indicated that the probability of delayed mortality associated with pulse pressure following the seven day monitoring period was the same for exposed and control fish of both species. Exposure to a single pulse from a small air gun array (10,160 cm3) was not lethal for pallid sturgeon and paddlefish. However, the risks from exposure to multiple sounds and to sound exposure levels that exceed those reported here remain to be examined. PMID:27505029
Effects of Exposure to the Sound from Seismic Airguns on Pallid Sturgeon and Paddlefish.
Popper, Arthur N; Gross, Jackson A; Carlson, Thomas J; Skalski, John; Young, John V; Hawkins, Anthony D; Zeddies, David
2016-01-01
This study examined the effects of exposure to a single acoustic pulse from a seismic airgun array on caged endangered pallid sturgeon (Scaphirhynchus albus) and on paddlefish (Polyodon spathula) in Lake Sakakawea (North Dakota, USA). The experiment was designed to detect the onset of physiological responses including minor to mortal injuries. Experimental fish were held in cages as close as 1 to 3 m from the guns where peak negative sound pressure levels (Peak- SPL) reached 231 dB re 1 μPa (205 dB re 1 μPa2·s sound exposure level [SEL]). Additional cages were placed at greater distances in an attempt to develop a dose-response relationship. Treatment and control fish were then monitored for seven days, euthanized, and necropsied to determine injuries. Necropsy results indicated that the probability of delayed mortality associated with pulse pressure following the seven day monitoring period was the same for exposed and control fish of both species. Exposure to a single pulse from a small air gun array (10,160 cm3) was not lethal for pallid sturgeon and paddlefish. However, the risks from exposure to multiple sounds and to sound exposure levels that exceed those reported here remain to be examined.
Mencias, Tara; Noon, Megan; Hoch, Anne Z
2012-03-01
To evaluate the screening practices and preparticipation evaluation (PPE) forms used to identify college athletes at risk for the female athlete triad (triad). Phone and/or e-mail survey. National Collegiate Athletic Association (NCAA) Division I universities. All 347 NCAA Division I universities were invited to participate in a survey, with 257 participating in the survey (74%) and 287 forms collected (83%). Information about the nature of the PPE was requested from team physicians and certified athletic trainers during a phone or e-mail survey. In addition, a copy of their PPE form was requested to evaluate for inclusion of the 12 items recommended by the Female Athlete Triad Coalition for primary screening for the triad. All 257 universities (100%) required a PPE for incoming athletes; however, only 83 universities (32%) required an annual PPE for returning athletes. Screening was performed on campus at 218 universities (85%). Eleven universities (4%) were using the recently updated fourth edition PPE. Only 25 universities (9%) had 9 or more of the 12 recommended items included in their forms, whereas 127 universities (44%) included 4 or less items. Relevant items that were omitted from more than 40% of forms included losing weight to meet the image requirements of a sport; using vomiting, diuretics, and/or laxatives to lose weight; and the number of menses experienced in the past 12 months. The current PPE forms used by NCAA Division I universities may not effectively screen for the triad.
Taylor, Silas; Shulruf, Boaz
2016-01-01
Peer physical examination (PPE), by which junior medical students learn physical examination skills before practicing on patients, is a widely implemented and accepted part of medical curricula. However, the ethical implications of PPE have been debated, since issues including student gender impact on its acceptability. Research has previously demonstrated the phenomenon of 'attitude-behavior inconsistency' showing that students' predictions about their participation in PPE differ from what they actually do in practice. This study asks whether gender and student self-ratings of outlook affect engagement in PPE. This study gathered data from students who had completed PPE with the objective of determining what factors have the greatest impact on the actual practice of PPE by students. Data were used to derive the number of opportunities students had to examine a peer, for various body parts. Respondent gender and self-ratings of outlook were recorded. Responses from 130 students were analysed: 74 female (57%) and 56 male (43%). Students have fewer opportunities to examine peers of the opposite gender; this is statistically significant for all body parts when male students examine female peers. Gender is the factor of overriding importance on whether these peer interactions actually occur, such that students have fewer opportunities to examine peers of the opposite gender, particularly male students examining female peers. Student outlook has little impact. We speculate that the more acceptable PPE is to participants, paradoxically, the more complicated these interactions become, possibly with implications for future practice.
The influence of students' gender on equity in Peer Physical Examination: a qualitative study.
Vnuk, Anna K; Wearn, Andy; Rees, Charlotte E
2017-08-01
Peer Physical Examination (PPE) is an educational tool used globally for learning early clinical skills and anatomy. In quantitative research, there are differences in students' preferences and actual participation in PPE by gender. This novel study qualitatively explores the effect that gender has on medical students' experiences of learning physical examination through PPE. We employ an interpretative approach to uncover the PPE experiences of students from a European, graduate-entry medical school. Volunteers participated in either individual or group interviews. The data were transcribed, de-identified and analysed using thematic analysis. There was evidence of gender inequity in PPE, with students describing significant imbalances in participation. Male students adopted roles that generated significant personal discomfort and led to fewer experiences as examiners. Assumptions were made by tutors and students about gender roles: male students' ready acceptance of exposure to be examined and female students' need to be protected from particular examinations. In contrast with the first assumption, male students did feel coerced or obliged to be examined. Students described their experiences of taking action to break down the gender barrier. Importantly, students reported that tutors played a role in perpetuating inequities. These findings, whilst relating to one university, have implications for all settings where PPE is used. Educators should be vigilant about gender issues and the effect that they may have on students' participation in PPE to ensure that students are not disadvantaged in their learning.
Effects of porcine pancreatic enzymes on the pancreas of hamsters. Part 1: basic studies.
Saruc, Murat; Nozawa, Fumiaki; Yalniz, Mehmet; Itami, Atsushi; Pour, Parviz M
2012-09-10
Porcine pancreatic enzymes (PPE) extracted from glandular stomach has been used for the treatment of pancreatic cancer patients. Unfortunately, no information is available on the in vitro and in vivo effect on the pancreas and other tissues. We used Syrian Golden hamsters, a unique pancreatic cancer model, to obtain basic information on PPE for its eventual use for the treatment of pancreatic cancer. PPE was used in different concentrations in vitro and in vivo. The stability of the enzyme in the water solution was investigated. It was given to the hamsters by gavage in concentrations of 1g/kg and 400 mg/kg for short periods and in aqueous solution for 65 days. Plasma enzyme and insulin, the size of islets and the number of the insulin cells per islet were examined. The enzyme activity of PPE was maintained in water solution for at least 24 hours. Due to its content of calcium chloride it showed a high toxicity to normal and malignant hamster pancreatic cancer cells and human pancreatic cancer cell lines in vitro. PPE did not alter the plasma pancreatic enzyme levels regardless of the dose, duration and application route. On the contrary, PPE reduced their levels significantly. Remarkably, it also reduced the level of insulin, the size of the islets and the number of insulin cells in the islets significantly. The results imply that PPE does not enter the blood circulation but it appears to slow down the function of both the exocrine and endocrine pancreas.
Fogel, Itay; David, Osant; Balik, Chaya H; Eisenkraft, Arik; Poles, Lion; Shental, Omri; Kassirer, Michael; Brosh-Nissimov, Tal
2017-11-01
The recent Ebola virus disease outbreak emphasized the potential misuse of personal protective equipment (PPE) by health care workers (HCWs) during such an event. We aimed to compare self-perceived proficiency of PPE use and objective performance, and identify predictors of low compliance and PPE misuse. An observational study combined with subjective questionnaires were carried out during a bioterror simulation drill. Forty-two observers evaluated performance under PPE. Mistakes were recorded and graded using a structured observational format and were correlated with the subjective questionnaires and with demographic parameters. One hundred seventy-eight HCWs from community clinics and hospitals were included. The mean self-perceived proficiency was high (6.1 out of 7), mean level of comfort was moderate (4.0 out of 7), and mean objective performance was intermediate (9.5 out of 13). There was no correlation between comfort and objective performance scores. Self-perceived proficiency was in correlation with donning and continuous performance with PPE but not with doffing. Clinic personnel performed better than personnel in hospitals (40.3% vs 67.8% with 3 or more mistakes, respectively; P = .001). Demographic characteristics had no correlation with objective or self-perceived performance. Self-perceived proficiency is a poor predictor of appropriate PPE use. The results suggest poor awareness of the possibility of PPE misuse. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Treatment of Palmar Plantar Erythrodysesthesia (PPE) with Topical Sildenafil: A Pilot Study
Meadows, Kellen L.; Rushing, Christel; Honeycutt, Wanda; Latta, Kenneth; Howard, Leigh; Arrowood, Christy A.; Niedzwiecki, Donna; Hurwitz, Herbert I.
2016-01-01
Purpose Palmar-plantar erythrodysethesia (PPE) is a common chemotherapy and anti-VEGF multi-kinase inhibitor class-related toxicity that often results in debilitating skin changes and often limits the use of active anti-cancer regimens. Mechanistic and anecdotal clinical evidence suggested that topical application of sildenafil cream may help reduce the severity of PPE. Therefore, we conducted a randomized, double-blind, placebo-controlled pilot study to evaluate the feasibility, safety and efficacy of topical sildenafil cream for the treatment of PPE. Methods Eligible subjects were required to have grade 1–3 PPE associated with either capecitabine or sunitinib. Subjects were randomized to receive 1% topical sildenafil cream to the left extremities or right extremities and placebo cream on the opposite extremity. 0.5 mL of cream was applied to each affected hand/foot two times per day. The primary endpoint was improvement in PPE grading at any point on study. Clinical assessments were evaluated by NCI-CTC 4.0 grading and patient self-reported pain. Results Ten subjects were enrolled; 9 were evaluable for safety and efficacy. Five of nine subjects reported some improvement in foot pain and 3 of 8 subjects for hand pain improvement. One of these subjects noted specific improvement in tactile function. No treatment-related toxicities were observed. Conclusions In this limited, single center study, topical cream containing 1% sildenafil is feasible to administer, is well-tolerated, and may mitigate PPE-related symptoms due to anti-cancer therapeutic agents. Further validation is necessary. PMID:25341548
Analysis of serum chemokine levels in patients with HIV-associated eosinophilic folliculitis.
Yokobayashi, H; Sugaya, M; Miyagaki, T; Kai, H; Suga, H; Yamada, D; Minatani, Y; Watanabe, K; Kikuchi, Y; Tamaki, T; Sato, S
2013-02-01
Patients with human immunodeficiency virus (HIV) infection exhibit various skin diseases. HIV-associated eosinophilic folliculitis (EF) and pruritic papular eruption (PPE) are frequently seen. To understand the mechanisms underlying HIV-associated EF and PPE. In order to know frequencies of EF and PPE among patients with HIV infection, we first collected HIV(+) patients who visited dermatology clinic in National Center for Global Health and Medicine during February 2007. We next collected 25 serum samples from HIV(+) patients with skin diseases from May 2008 to May 2010. Eight of 25 patients had EF (EF group), four had PPE (PPE group) and others had non-itchy skin problems such as condyloma acuminatum (no itch group). We first confirmed high frequencies of EF (10.7%) and PPE (5.3%) among 75 HIV(+) patients who visited our clinic during one month. We then measured serum levels of CCL11, CCL17, CCL26 and CCL27. Serum CCL17 levels in EF were significantly higher than those of PPE and no itch group. Serum CCL26 and CCL27 levels in EF were higher than those of no itch group. The number of CD4(+) cells in EF was significantly lower than that in no itch group. High serum levels of CCL17, CCL26 and CCL27, and low CD4(+) cell counts may account for the development of HIV-associated EF. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.
Zhang, Bin; Liu, Xia; Zhao, Guangyao; Mao, Xinguo; Li, Ang; Jing, Ruilian
2014-06-01
Wheat (Triticum aestivum L.) is one of the most important crops in the world. Squamosa-promoter binding protein (SBP)-box genes play a critical role in regulating flower and fruit development. In this study, 10 novel SBP-box genes (TaSPL genes) were isolated from wheat ((Triticum aestivum L.) cultivar Yanzhan 4110). Phylogenetic analysis classified the TaSPL genes into five groups (G1-G5). The motif combinations and expression patterns of the TaSPL genes varied among the five groups with each having own distinctive characteristics: TaSPL20/21 in G1 and TaSPL17 in G2 mainly expressed in the shoot apical meristem and the young ear, and their expression levels responded to development of the ear; TaSPL6/15 belonging to G3 were upregulated and TaSPL1/23 in G4 were downregulated during grain development; the gene in G5 (TaSPL3) expressed constitutively. Thus, the consistency of the phylogenetic analysis, motif compositions, and expression patterns of the TaSPL genes revealed specific gene structures and functions. On the other hand, the diverse gene structures and different expression patterns suggested that wheat SBP-box genes have a wide range of functions. The results also suggest a potential role for wheat SBP-box genes in ear development. This study provides a significant beginning of functional analysis of SBP-box genes in wheat. © 2014 The Authors. Journal of Integrative Plant Biology Published by Wiley Publishing Asia Pty Ltd on behalf of Institute of Botany, Chinese Academy of Sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foust, C.B.
An incident involving chemical warfare agents requires a unique hazardous materials (HAZMAT) response. As with an HAZMAT event, federal regulations prescribe that responders must be protected from exposure to the chemical agents. But unlike other HAZMAT events, special considerations govern selection of personal protective equipment (PPE). PPE includes all clothing, respirators and monitoring devices used to respond to a chemical release. PPE can differ depending on whether responders are military or civilian personnel.
Phase Calibration of Microphones by Measurement in the Free-field
NASA Technical Reports Server (NTRS)
Shams, Qamar A.; Bartram, Scott M.; Humphreys, William M.; Zuckewar, Allan J.
2006-01-01
Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.
Profiling structured product labeling with NDF-RT and RxNorm
2012-01-01
Background Structured Product Labeling (SPL) is a document markup standard approved by Health Level Seven (HL7) and adopted by United States Food and Drug Administration (FDA) as a mechanism for exchanging drug product information. The SPL drug labels contain rich information about FDA approved clinical drugs. However, the lack of linkage to standard drug ontologies hinders their meaningful use. NDF-RT (National Drug File Reference Terminology) and NLM RxNorm as standard drug ontology were used to standardize and profile the product labels. Methods In this paper, we present a framework that intends to map SPL drug labels with existing drug ontologies: NDF-RT and RxNorm. We also applied existing categorical annotations from the drug ontologies to classify SPL drug labels into corresponding classes. We established the classification and relevant linkage for SPL drug labels using the following three approaches. First, we retrieved NDF-RT categorical information from the External Pharmacologic Class (EPC) indexing SPLs. Second, we used the RxNorm and NDF-RT mappings to classify and link SPLs with NDF-RT categories. Third, we profiled SPLs using RxNorm term type information. In the implementation process, we employed a Semantic Web technology framework, in which we stored the data sets from NDF-RT and SPLs into a RDF triple store, and executed SPARQL queries to retrieve data from customized SPARQL endpoints. Meanwhile, we imported RxNorm data into MySQL relational database. Results In total, 96.0% SPL drug labels were mapped with NDF-RT categories whereas 97.0% SPL drug labels are linked to RxNorm codes. We found that the majority of SPL drug labels are mapped to chemical ingredient concepts in both drug ontologies whereas a relatively small portion of SPL drug labels are mapped to clinical drug concepts. Conclusions The profiling outcomes produced by this study would provide useful insights on meaningful use of FDA SPL drug labels in clinical applications through standard drug ontologies such as NDF-RT and RxNorm. PMID:23256517
Profiling structured product labeling with NDF-RT and RxNorm.
Zhu, Qian; Jiang, Guoqian; Chute, Christopher G
2012-12-20
Structured Product Labeling (SPL) is a document markup standard approved by Health Level Seven (HL7) and adopted by United States Food and Drug Administration (FDA) as a mechanism for exchanging drug product information. The SPL drug labels contain rich information about FDA approved clinical drugs. However, the lack of linkage to standard drug ontologies hinders their meaningful use. NDF-RT (National Drug File Reference Terminology) and NLM RxNorm as standard drug ontology were used to standardize and profile the product labels. In this paper, we present a framework that intends to map SPL drug labels with existing drug ontologies: NDF-RT and RxNorm. We also applied existing categorical annotations from the drug ontologies to classify SPL drug labels into corresponding classes. We established the classification and relevant linkage for SPL drug labels using the following three approaches. First, we retrieved NDF-RT categorical information from the External Pharmacologic Class (EPC) indexing SPLs. Second, we used the RxNorm and NDF-RT mappings to classify and link SPLs with NDF-RT categories. Third, we profiled SPLs using RxNorm term type information. In the implementation process, we employed a Semantic Web technology framework, in which we stored the data sets from NDF-RT and SPLs into a RDF triple store, and executed SPARQL queries to retrieve data from customized SPARQL endpoints. Meanwhile, we imported RxNorm data into MySQL relational database. In total, 96.0% SPL drug labels were mapped with NDF-RT categories whereas 97.0% SPL drug labels are linked to RxNorm codes. We found that the majority of SPL drug labels are mapped to chemical ingredient concepts in both drug ontologies whereas a relatively small portion of SPL drug labels are mapped to clinical drug concepts. The profiling outcomes produced by this study would provide useful insights on meaningful use of FDA SPL drug labels in clinical applications through standard drug ontologies such as NDF-RT and RxNorm.
Tripathi, Rajiv K; Goel, Ridhi; Kumari, Sweta; Dahuja, Anil
2017-03-01
SQUAMOSA Promoter-Binding Protein-Like (SPL) genes form a major family of plant-specific transcription factors and play an important role in plant growth and development. In this study, we report the identification of 41 SPL genes (GmSPLs) in the soybean genome. Phylogenetic analysis revealed that these genes were divided into five groups (groups 1-5). Further, exon/intron structure and motif composition revealed that the GmSPL genes are conserved within their same group. The N-terminal zinc finger 1 (Zn1) of the SBP domain was a CCCH (Cys3His1) and the C terminus zinc finger 2 (Zn2) was a CCHC (Cys2HisCys) type. The 41 GmSPL genes were distributed unevenly on 17 of the 20 chromosomes, with tandem and segmental duplication events. We found that segmental duplication has made an important contribution to soybean SPL gene family expansion. The Ka/Ks ratios revealed that the duplicated GmSPL genes evolved under the effect of purifying selection. In addition, 17 of the 41 GmSPLs were found as targets of miR156; these might be involved in their posttranscriptional regulation through miR156. Importantly, RLM-RACE analysis confirmed the GmmiR156-mediated cleavage of GmSPL2a transcript in 2-4 mm stage of soybean seed. Alternative splicing events in 9 GmSPLs were detected which produces transcripts and proteins of different lengths that may modulate protein signaling, binding, localization, stability, and other properties. Expression analysis of the soybean SPL genes in various tissues and different developmental stages of seed suggested distinct spatiotemporal patterns. Differences in the expression patterns of miR156-targeted and miR156-non-targeted soybean SPL genes suggest that miR156 plays key functions in soybean development. Our results provide an important foundation for further uncovering the crucial roles of GmSPLs in the development of soybean and other biological processes.
Personal Protective Equipment in Animal Research
Villano, Jason S; Follo, Janet M; Chappell, Mark G; Jr, Morris T Collins
2017-01-01
The occupational health and safety program is an integral component of a comprehensive animal care and use program. It is important to mitigate the risk of exposures of animal care and research personnel to allergens and physical, chemical, radiologic, and biologic hazards during the conduct of various tasks. This need is especially true in infectious disease and biocontainment research. One aspect of the program is the provision of personal protective equipment (PPE). Commercially available PPE should be carefully evaluated based on their material composition and performance according to manufacturer data. To help institutions and end users by providing them guidance on choosing appropriate PPE, we here discuss the regulatory framework, device standards, and materials engineering for various PPE, including gloves, shoe covers, head caps, gowns, aprons, masks, hearing and eye protection devices, and respirators. Ultimately, the choice of appropriate PPE is based on the risk assessment, which should include consideration for personnel comfort, correct device fitting, and the containment level for the hazard used. PMID:28662749
Sequence Polishing Library (SPL) v10.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oberortner, Ernst
The Sequence Polishing Library (SPL) is a suite of software tools in order to automate "Design for Synthesis and Assembly" workflows. Specifically: The SPL "Converter" tool converts files among the following sequence data exchange formats: CSV, FASTA, GenBank, and Synthetic Biology Open Language (SBOL); The SPL "Juggler" tool optimizes the codon usages of DNA coding sequences according to an optimization strategy, a user-specific codon usage table and genetic code. In addition, the SPL "Juggler" can translate amino acid sequences into DNA sequences.:The SPL "Polisher" verifies NA sequences against DNA synthesis constraints, such as GC content, repeating k-mers, and restriction sites.more » In case of violations, the "Polisher" reports the violations in a comprehensive manner. The "Polisher" tool can also modify the violating regions according to an optimization strategy, a user-specific codon usage table and genetic code;The SPL "Partitioner" decomposes large DNA sequences into smaller building blocks with partial overlaps that enable an efficient assembly. The "Partitioner" enables the user to configure the characteristics of the overlaps, which are mostly determined by the utilized assembly protocol, such as length, GC content, or melting temperature.« less
NASA Astrophysics Data System (ADS)
Howard, Mackenzie A.; Stagner, Barden B.; Lonsbury-Martin, Brenda L.; Martin, Glen K.
2002-01-01
Distortion-product otoacoustic emissions (DPOAEs) at 2f1-f2 can be suppressed by the introduction of a third ``suppressor'' tone. Plotting the suppression of the DPOAE level against the changing frequency and level of the suppressor produces frequency-tuning functions referred to as suppression tuning curves (STCs). The dominant features of STCs, including their shape, are similar to the features of neural tuning curves (NTCs) recorded from single auditory nerve fibers. However, recent findings using reversible diuretics suggest that STCs do not provide the same measure of cochlear frequency selectivity as provided by NTCs. To determine if STCs are also insensitive to the adverse effects of excessive sounds, the present study exposed rabbits to a moderate-level noise that produced temporary threshold shift-like (TTS) effects on DPOAEs, and examined the influence of such exposures on STCs. DPOAEs were produced using primary tones with geometric-mean frequencies centered at 2.8 or 4 kHz, and with L1 and L2 values of 45/45, 50/35, 50/50, and 55/45 dB SPL. STCs were obtained before and during recovery for a period of approximately 2 h immediately following, and at 1, 2, 3, and 7 d post-exposure to a 2 kHz octave band noise, at levels and durations sufficient to cause significant but reversible reductions in DPOAE levels. STC data included tip center frequency, tip threshold, and Q10dB measures of tuning for suppression criteria of 3, 6, 9, and 12 dB. Recovery was variable between animals, but all rabbits recovered fully by 7 d post-exposure. STC center frequencies measured during the TTS typically tuned to a slightly higher frequency, while tip thresholds tended to decrease and Q10dB increase. Together, the results indicate that, despite similarities in the general properties of STCs and NTCs, these two types of tuning curves are affected differently following reversible cochlear insult.
Air Traffic Controllers’ Long-Term Speech-in-Noise Training Effects: A Control Group Study
Zaballos, María T.P.; Plasencia, Daniel P.; González, María L.Z.; de Miguel, Angel R.; Macías, Ángel R.
2016-01-01
Introduction: Speech perception in noise relies on the capacity of the auditory system to process complex sounds using sensory and cognitive skills. The possibility that these can be trained during adulthood is of special interest in auditory disorders, where speech in noise perception becomes compromised. Air traffic controllers (ATC) are constantly exposed to radio communication, a situation that seems to produce auditory learning. The objective of this study has been to quantify this effect. Subjects and Methods: 19 ATC and 19 normal hearing individuals underwent a speech in noise test with three signal to noise ratios: 5, 0 and −5 dB. Noise and speech were presented through two different loudspeakers in azimuth position. Speech tokes were presented at 65 dB SPL, while white noise files were at 60, 65 and 70 dB respectively. Results: Air traffic controllers outperform the control group in all conditions [P<0.05 in ANOVA and Mann-Whitney U tests]. Group differences were largest in the most difficult condition, SNR=−5 dB. However, no correlation between experience and performance were found for any of the conditions tested. The reason might be that ceiling performance is achieved much faster than the minimum experience time recorded, 5 years, although intrinsic cognitive abilities cannot be disregarded. Discussion: ATC demonstrated enhanced ability to hear speech in challenging listening environments. This study provides evidence that long-term auditory training is indeed useful in achieving better speech-in-noise understanding even in adverse conditions, although good cognitive qualities are likely to be a basic requirement for this training to be effective. Conclusion: Our results show that ATC outperform the control group in all conditions. Thus, this study provides evidence that long-term auditory training is indeed useful in achieving better speech-in-noise understanding even in adverse conditions. PMID:27991470
Peer physical examination: time to revisit?
Outram, Suzanne; Nair, Balakrishnan R
2008-09-01
Opportunities for using inpatients for learning physical examination skills have decreased. In peer physical examination (PPE), students act as models for each other to learn skills in physical examination and other non-invasive procedures. PPE is extensively used and has high acceptability, but nevertheless poses some challenges. PPE may be less acceptable among culturally and linguistically diverse students. In the light of our findings and the published literature, best practice points are described.
Rees, Charlotte E; Wearn, Andy M; Vnuk, Anna K; Bradley, Paul A
2009-10-01
Although recent quantitative research suggests that medical students are reluctant to engage in peer physical examination (PPE) of intimate body regions, we do not know why. This article explores first-year medical students' anxieties about PPE of intimate body regions at six schools. Using the Examining Fellow Students (EFS) questionnaire, we collected qualitative data from students in five countries (UK; Australia; New Zealand; Japan; Hong Kong) between 2005 and 2007. Our framework analysis of 617 (78.7%) students' qualitative comments yielded three themes: present and future benefits of PPE; possible barriers to PPE; and student stipulations for successful PPE. This article focuses on several sub-themes relating to students' anxieties about PPE of intimate body regions and their associated sexual, gender, cultural and religious concerns. By exploring students' euphemisms about intimate areas, our findings reveal further insights into the relationship between students' anxieties, gender and culture. First-year students are anxious about examining intimate body regions, so a staged approach starting with manikins is recommended. Further qualitative research is needed employing interviews to explore in depth students' anxieties about examinations of intimate body regions and how their views are shaped by interactions with peers, patients and doctors.
Tanner, Kristine; Roy, Nelson; Merrill, Ray M; Muntz, Faye; Houtz, Daniel R; Sauder, Cara; Elstad, Mark; Wright-Costa, Julie
2010-12-01
To examine the effects of nebulized isotonic saline (IS) versus sterile water (SW) on self-perceived phonatory effort (PPE) and phonation threshold pressure (PTP) following a surface laryngeal dehydration challenge in classically trained sopranos. In a double-blind, within-subject crossover design, 34 sopranos breathed dry air (relative humidity < 1%) transorally for 15 min and then nebulized 3 mL of IS or SW, or experienced a no-treatment control condition over 3 consecutive weeks. PPE and PTP were measured every 15 min from baseline through 2 hr postdesiccation. PPE increased significantly following the laryngeal desiccation challenge in all 3 treatment conditions (p < .01). After nebulization, PPE returned to baseline for the IS condition only. For the SW and control conditions, PPE remained above baseline during the 2 hr after desiccation. No statistically significant changes in PTP following laryngeal desiccation were observed, although values for the IS condition remained below baseline for nearly 2 hr after nebulization. PPE and PTP were not significantly correlated. Following a laryngeal surface dehydration challenge, classically trained sopranos reported increased vocal effort that persisted for at least 2 hr. Compared with SW, nebulized IS showed promise as an effective way to remediate the adverse, self-perceived effects of laryngeal desiccation.
Ahmed, Lamiaa Ali
2014-01-01
This study aimed to evaluate the renoprotective effect of Physalis peruviana L. extract (PPE) on acute renal injury in rats. Adult male rats (n = 36) were divided into six groups that were fed with basal diet throughout the experiment (33 days). The first group was normal group, the second and the third groups were administered orally with 100 and 150 mg PPE/kg body weight (BW) respectively, the fourth group was injected intraperitoneally with 5 mg/kg BW cisplatin once on the 28th day to induced ARI, and the fifth and sixth groups were treated like the second and the third groups and were injected with cisplatin on the 28th day. Many bioactive compounds were found in PPE. PPE did not cause any changes in the second and third groups compared to normal control group. Administration of PPE prior to cisplatin injection caused significant reduction in relative kidney weight, serum creatinine, urea, blood urea nitrogen, and significant increments in body weight, feed intake, total protein, albumin, and total globulin compared to cisplatin group. Pretreatment with PPE improved kidney histology and diminished the level of thiobarbituric acid reactive substances and enhanced other antioxidant enzymes in kidney homogenate compared to cisplatin group. PMID:24757415
Ahmed, Lamiaa Ali
2014-01-01
This study aimed to evaluate the renoprotective effect of Physalis peruviana L. extract (PPE) on acute renal injury in rats. Adult male rats (n = 36) were divided into six groups that were fed with basal diet throughout the experiment (33 days). The first group was normal group, the second and the third groups were administered orally with 100 and 150 mg PPE/kg body weight (BW) respectively, the fourth group was injected intraperitoneally with 5 mg/kg BW cisplatin once on the 28th day to induced ARI, and the fifth and sixth groups were treated like the second and the third groups and were injected with cisplatin on the 28th day. Many bioactive compounds were found in PPE. PPE did not cause any changes in the second and third groups compared to normal control group. Administration of PPE prior to cisplatin injection caused significant reduction in relative kidney weight, serum creatinine, urea, blood urea nitrogen, and significant increments in body weight, feed intake, total protein, albumin, and total globulin compared to cisplatin group. Pretreatment with PPE improved kidney histology and diminished the level of thiobarbituric acid reactive substances and enhanced other antioxidant enzymes in kidney homogenate compared to cisplatin group.
Normative data for stretched penile length in term neonates born in Tamil Nadu.
Prabhu, Sudha Rathna; Mahadevan, Shriraam; Bharath, R; Jagadeesh, Sujatha; Kumutha, J; Suresh, Seshadri
2014-07-01
To establish normative data for stretched penile length (SPL) in term male neonates born in Tamil Nadu. All live term male neonates delivered in a hospital during a given period were included. SPL was measured from the pubic ramus to the tip of the glans. Two consecutive measurements were taken and average was recorded. The mean SPL observed in our study was 2.83 ± 0.49 cm. This study helps establish normative values for SPL in neonates of Tamil Nadu origin.
Reverberance of AN Existing Hall in Relation to both Subsequent Reverberation Time and Spl
NASA Astrophysics Data System (ADS)
HASE, S.; TAKATSU, A.; SATO, S.; SAKAI, H.; ANDO, Y.
2000-04-01
The reverberance of sound fields was evaluated by psychological tests in a multi-purpose hall with 400 seats. Both the subsequent reverberation time (Tsub) and sound pressure level (SPL) were changed, and the scale values of reverberance for both the music and speech signals were obtained by using the paired comparison method. This study found that Tsuband SPL have an independent influence on the scale value of reverberance. The reverberance increases when both Tsuband SPL are increased.
2016-01-01
Purpose Peer physical examination (PPE), by which junior medical students learn physical examination skills before practicing on patients, is a widely implemented and accepted part of medical curricula. However, the ethical implications of PPE have been debated, since issues including student gender impact on its acceptability. Research has previously demonstrated the phenomenon of ‘attitude-behavior inconsistency’ showing that students’ predictions about their participation in PPE differ from what they actually do in practice. This study asks whether gender and student self-ratings of outlook affect engagement in PPE. Methods This study gathered data from students who had completed PPE with the objective of determining what factors have the greatest impact on the actual practice of PPE by students. Data were used to derive the number of opportunities students had to examine a peer, for various body parts. Respondent gender and self-ratings of outlook were recorded. Results Responses from 130 students were analysed: 74 female (57%) and 56 male (43%). Students have fewer opportunities to examine peers of the opposite gender; this is statistically significant for all body parts when male students examine female peers. Conclusion Gender is the factor of overriding importance on whether these peer interactions actually occur, such that students have fewer opportunities to examine peers of the opposite gender, particularly male students examining female peers. Student outlook has little impact. We speculate that the more acceptable PPE is to participants, paradoxically, the more complicated these interactions become, possibly with implications for future practice. PMID:27894184
Chromatin-associated regulation of sorbitol synthesis in flower buds of peach.
Lloret, Alba; Martínez-Fuentes, Amparo; Agustí, Manuel; Badenes, María Luisa; Ríos, Gabino
2017-11-01
PpeS6PDH gene is postulated to mediate sorbitol synthesis in flower buds of peach concomitantly with specific chromatin modifications. Perennial plants have evolved an adaptive mechanism involving protection of meristems within specialized structures named buds in order to survive low temperatures and water deprivation during winter. A seasonal period of dormancy further improves tolerance of buds to environmental stresses through specific mechanisms poorly known at the molecular level. We have shown that peach PpeS6PDH gene is down-regulated in flower buds after dormancy release, concomitantly with changes in the methylation level at specific lysine residues of histone H3 (H3K27 and H3K4) in the chromatin around the translation start site of the gene. PpeS6PDH encodes a NADPH-dependent sorbitol-6-phosphate dehydrogenase, the key enzyme for biosynthesis of sorbitol. Consistently, sorbitol accumulates in dormant buds showing higher PpeS6PDH expression. Moreover, PpeS6PDH gene expression is affected by cold and water deficit stress. Particularly, its expression is up-regulated by low temperature in buds and leaves, whereas desiccation treatment induces PpeS6PDH in buds and represses the gene in leaves. These data reveal the concurrent participation of chromatin modification mechanisms, transcriptional regulation of PpeS6PDH and sorbitol accumulation in flower buds of peach. In addition to its role as a major translocatable photosynthate in Rosaceae species, sorbitol is a widespread compatible solute and cryoprotectant, which suggests its participation in tolerance to environmental stresses in flower buds of peach.
Morzelle, Maressa Caldeira; Salgado, Jocelem Mastrodi; Telles, Milena; Mourelle, Danilo; Bachiega, Patricia; Buck, Hudson Sousa
2016-01-01
Alzheimer’s disease is a chronic and degenerative condition that had no treatment until recently. The current therapeutic strategies reduce progression of the disease but are expensive and commonly cause side effects that are uncomfortable for treated patients. Functional foods to prevent and/or treat many conditions, including neurodegenerative diseases, represent a promising field of study currently gaining attention. To this end, here we demonstrate the effects of pomegranate (Punica granatum) peel extract (PPE) regarding spatial memory, biomarkers of neuroplasticity, oxidative stress and inflammation in a mouse model of neurodegeneration. Male C57Bl/6 mice were chronically infused for 35 days with amyloid-β peptide 1–42 (Aβ) or vehicle (control) using mini-osmotic pumps. Another group, also infused with Aβ, was treated with PPE (p.o.– βA+PPE, 800 mg/kg/day). Spatial memory was evaluated in the Barnes maze. Animals treated with PPE and in the control group exhibited a reduction in failure to find the escape box, a finding that was not observed in the Aβ group. The consumption of PPE reduced amyloid plaque density, increased the expression of neurotrophin BDNF and reduced the activity of acetylcholinesterase enzyme. A reduction in lipid peroxidation and in the concentration of the pro-inflammatory cytokine TNF-α was also observed in the PPE group. No hepatic lesions were observed in animals treated with PPE. In conclusion, administration of pomegranate peel extract has neuroprotective effects involving multiple mechanisms to prevent establishment and progression of the neurodegenerative process induced by infusion with amyloid-β peptide in mice. PMID:27829013
Rees, Charlotte E; Wearn, Andy M; Vnuk, Anna K; Sato, Toshio J
2009-03-01
Although studies have begun to shed light on medical students' attitudes towards peer physical examination (PPE), they have been conducted at single sites, and have generally not examined changes in medical students' attitudes over time. Employing both cross-sectional and longitudinal designs, the current study examines medical students' attitudes towards PPE at schools from different geographical and cultural regions and assess changes in their attitudes over their first year of medical study. Students at six schools (Peninsula, UK; Durham, UK; Auckland, New Zealand; Flinders, Australia; Sapporo, Japan and Li Ka Shing, Hong Kong) completed the Examining Fellow Students (EFS) questionnaire near the start of their academic year (T1), and students at four schools (Peninsula, Durham, Auckland and Flinders) completed the EFS for a second time, around the end of their academic year (T2). Univariate and multivariate analyses revealed a high level of acceptance for PPE of non-intimate body regions amongst medical students from all schools (greater than 83%, hips, at T1 and 94.5%, hips and upper body, at T2). At T1 and T2, students' willingness to engage in PPE was associated with their gender, ethnicity, religiosity and school. Typically, students least comfortable with PPE at T1 and T2 were female, non-white, religious and studying at Auckland. Although students' attitudes towards PPE were reasonably stable over their first year of study, and after exposure to PPE, we did find some statistically significant differences in attitudes between T1 and T2. Interestingly, attitude changes were consistently predicted by gender, even when controlling for school. While male students' attitudes towards PPE were relatively stable over time, females' attitudes were changeable. In this paper, we discuss our findings in light of existing research and theory, and discuss their implications for educational practice and further research.
Dunn, Angela C; Walker, Tiffany A; Redd, John; Sugerman, David; McFadden, Jevon; Singh, Tushar; Jasperse, Joseph; Kamara, Brima Osaio; Sesay, Tom; McAuley, James; Kilmarx, Peter H
2016-03-01
In the largest Ebola virus disease (EVD) outbreak in history, nosocomial transmission of EVD increased spread of the disease. We report on 2 instances in Sierra Leone where patients unknowingly infected with EVD were admitted to a general hospital ward (1 pediatric ward and 1 maternity ward), exposing health care workers, caregivers, and other patients to EVD. Both patients died on the general wards, and were later confirmed as being infected with EVD. We initiated contact tracing and assessed risk factors for secondary infections to guide containment recommendations. We reviewed medical records to establish the index patients' symptom onset. Health care workers, patients, and caregivers were interviewed to determine exposures and personal protective equipment (PPE) use. Contacts were monitored daily for EVD symptoms. Those who experienced EVD symptoms were isolated and tested. Eighty-two contacts were identified: 64 health care workers, 7 caregivers, 4 patients, 4 newborns, and 3 children of patients. Seven contacts became symptomatic and tested positive for EVD: 2 health care workers (1 nurse and 1 hospital cleaner), 2 caregivers, 2 newborns, and 1 patient. The infected nurse placed an intravenous catheter in the pediatric index patient with only short gloves PPE and the hospital cleaner cleaned the operating room of the maternity ward index patient wearing short gloves PPE. The maternity ward index patient's caregiver and newborn were exposed to her body fluids. The infected patient and her newborn shared the ward and latrine with the maternity ward index patient. Hospital staff members did not use adequate PPE. Caregivers were not offered PPE. Delayed recognition of EVD and inadequate PPE likely led to exposures and secondary infections. Earlier recognition of EVD and adequate PPE might have reduced direct contact with body fluids. Limiting nonhealth-care worker contact, improving access to PPE, and enhancing screening methods for pregnant women, children, and inpatients may help decrease EVD transmission in general health care settings. Published by Elsevier Inc.
Belhamidi, Mohamed Said; Hammi, Salah Eddine; Bouzroud, Mohamed; Benmoussa, Mustapha; ali, Abdelmounaim Ait; Bounaim, Ahmed
2017-01-01
L’hypertension portale non cirrhotique est une affection décrite pour la première fois par Guido BANTI en 1898 comme une affection associant une hypertension portale avec splénomégalie et anémie sur foie sain. Le diagnostic repose sur l’échographie abdominale, la splénoportographie et la biopsie hépatique. Le but de notre travail est d’évaluer la place de la splénectomie dans l’hypertension portale non cirrhotique à travers une étude rétrospective portant sur 3 malades dont 2 femmes et un homme pris en charge dans notre formation entre Janvier 2010 et Septembre 2016. Le diagnostic de l’hypertension portale idiopathique a été basé sur les critères suivants : une hypertension portale, la présence des varices oesophagiènnes avec une splénomégalie, l’absence de cirrhose ou d’autres affections hépatiques responsables de l’hypertension portale. La splénectomie a été réalisée chez les 3 malades. L’évolution après la splénectomie était marquée par la normalisation des signes cliniques, radiologiques et biologiques de cette affection, avec absence de récidive des varices œsophagiennes. La splénectomie associée à la ligature des varices œsophagiennes pourraient être suffisantes pour traiter ce syndrome et surtout ses conséquences sans avoir recours à une dérivation spléno-rénale. PMID:29255554
Andrade, L F; Davide, L C; Gedraite, L S
2010-05-01
SPL (spent pot liner) is a solid waste produced by the aluminum industry. This waste has a highly variable composition, consisting of cyanides, fluorides, organics, and metals. The aim of this work was to study the effect of SPL on root tips of Lactuca sativa using current plant bioassays. We observed a decrease in the germination rate with increasing concentrations of SPL. In addition, SPL was found to reduce root growth, which is correlated with a decrease in the mitotic index. Nevertheless, we noticed a significant enhancement in the percentage of stickiness, c-metaphase, anaphase bridges, and laggard chromosomes in dividing cells and also an increase in the number of cells with condensed nuclei. Moreover, SPL was found to alter the root tip surface, resulting in a reduction in the amount of root hair. These results demonstrate that SPL is a toxic agent that leads to cell damage and disturbance. Copyright 2009 Elsevier Inc. All rights reserved.
Brief report: sound output of infant humidifiers.
Royer, Allison K; Wilson, Paul F; Royer, Mark C; Miyamoto, Richard T
2015-06-01
The sound pressure levels (SPLs) of common infant humidifiers were determined to identify the likely sound exposure to infants and young children. This primary investigative research study was completed at a tertiary-level academic medical center otolaryngology and audiology laboratory. Five commercially available humidifiers were obtained from brick-and-mortar infant supply stores. Sound levels were measured at 20-, 100-, and 150-cm distances at all available humidifier settings. Two of 5 (40%) humidifiers tested had SPL readings greater than the recommended hospital infant nursery levels (50 dB) at distances up to 100 cm. In this preliminary study, it was demonstrated that humidifiers marketed for infant nurseries may produce appreciably high decibel levels. Further characterization of the effect of humidifier design on SPLs and further elucidation of ambient sound levels associated with hearing risk are necessary before definitive conclusions and recommendations can be made. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
[Pre-operation evaluation and intra-operation management of cochlear implantation].
Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning
2004-10-01
To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.
Acoustic Liner Drag: A Parametric Study of Conventional Configurations
NASA Technical Reports Server (NTRS)
Howerton, Brian M.; Jones, Michael G.
2015-01-01
Interest in the characterization of the aerodynamic drag performance of acoustic liners has increased in the past several years. This paper details experiments in NASA Langley's Grazing Flow Impedance Tube to quantify the relative drag of several conventional perforate-over-honeycomb liner configurations. For a fixed porosity, facesheet hole diameter and cavity depth are varied to study the effect of each. These configurations are selected to span the range of conventional liner geometries used in commercial aircraft engines. Detailed static pressure and acoustic measurements are made for grazing flows up to M=0.5 at 140 dB SPL for tones between 400 and 2800 Hz. These measurements are used to calculate a resistance factor (?) for each configuration. Analysis shows a correlation between perforate hole size and the resistance factor but cavity depth seems to have little influence. Acoustic effects on liner drag are observed to be limited to the lower Mach numbers included in this investigation.
Analog-to-digital conversion to accommodate the dynamics of live music in hearing instruments.
Hockley, Neil S; Bahlmann, Frauke; Fulton, Bernadette
2012-09-01
Hearing instrument design focuses on the amplification of speech to reduce the negative effects of hearing loss. Many amateur and professional musicians, along with music enthusiasts, also require their hearing instruments to perform well when listening to the frequent, high amplitude peaks of live music. One limitation, in most current digital hearing instruments with 16-bit analog-to-digital (A/D) converters, is that the compressor before the A/D conversion is limited to 95 dB (SPL) or less at the input. This is more than adequate for the dynamic range of speech; however, this does not accommodate the amplitude peaks present in live music. The hearing instrument input compression system can be adjusted to accommodate for the amplitudes present in music that would otherwise be compressed before the A/D converter in the hearing instrument. The methodology behind this technological approach will be presented along with measurements to demonstrate its effectiveness.
A study on (K, Na) NbO3 based multilayer piezoelectric ceramics micro speaker
NASA Astrophysics Data System (ADS)
Gao, Renlong; Chu, Xiangcheng; Huan, Yu; Sun, Yiming; Liu, Jiayi; Wang, Xiaohui; Li, Longtu
2014-10-01
A flat panel micro speaker was fabricated from (K, Na) NbO3 (KNN)-based multilayer piezoelectric ceramics by a tape casting and cofiring process using Ag-Pd alloys as an inner electrode. The interface between ceramic and electrode was investigated by scanning electron microscope (SEM) and transmission electron microscope (TEM). The acoustic response was characterized by a standard audio test system. We found that the micro speaker with dimensions of 23 × 27 × 0.6 mm3, using three layers of 30 μm thickness KNN-based ceramic, has a high average sound pressure level (SPL) of 87 dB, between 100 Hz-20 kHz under five voltage. This result was even better than that of lead zirconate titanate (PZT)-based ceramics under the same conditions. The experimental results show that the KNN-based multilayer ceramics could be used as lead free piezoelectric micro speakers.
Palmieri, Marcel José; Luber, Jaquelini; Andrade-Vieira, Larissa Fonseca; Davide, Lisete Chamma
2014-03-15
Spent pot-liner (SPL) is a hazardous solid waste produced by the aluminum industry. Although its composition may vary, fluoride and cyanide salts as well as aluminum are predominant components. A seed-germination and root-elongation test was performed with Lactuca sativa seeds as a test system. SPL induced decrease of seed germination rate and root elongation. The concentration of 26.5g/L SPL was established from a regression curve as the IC50 (inhibition concentration 50%). Through chemical analyses, the concentrations of fluoride, cyanide and aluminum in SPL solutions of 26.5g/L (IC50), 39.75g/L (1.5IC50) and 13.25g/L (0.5IC50) were determined. Further, a cell-cycle test was conducted with root tips of L. sativa exposed to these same SPL solutions. All test chemicals presented toxic effects on meristematic cells of L. sativa. Aluminum was identified as the SPL component mainly responsible for reduction of the mitotic index. Chromosomal alterations resulted from the interactions among the three main chemical components of SPL, without a clear predominantly responsible agent. Induction of condensed nuclei was mainly due to effects of aluminum and fluoride, and may serve as an indicator of induced cell death. Copyright © 2014 Elsevier B.V. All rights reserved.
Dowd, Karen; Taylor, Melanie; Toribio, Jenny-Ann L M L; Hooker, Claire; Dhand, Navneet K
2013-08-01
This study was conducted to determine the perceptions of zoonotic disease risk among Australian veterinarians, the infection control practices they use to protect themselves from zoonotic diseases, and the factors influencing their use of these protective practices. A questionnaire was designed and piloted prior to its administration to veterinarians at the annual Australian Veterinary Association Conference in May 2011. The questionnaire comprised 21 closed, semi-closed and open questions. Data from the questionnaire were analyzed using ordinal logistic regression analyses to determine significant factors for veterinarians' use of personal protective equipment (PPE). A total of 344 veterinarians completed the questionnaire of which 63.7% were women, 63.2% worked in small/companion animal practice, and 79.9% worked in private veterinary practice. Of the respondents, 44.9% reported contracting a zoonosis during their careers with 19.7% reporting a suspected case and 25.2% reporting a confirmed incidence. Around 40-60% of veterinarians perceived exposure to zoonosis likely or very likely in a variety of situations. With reference to current national industry guidelines, the reported use of PPE was less than "adequate" for most scenarios except for performing postmortems, surgery or dental procedures. No PPE was used by 60-70% of veterinarians for treating respiratory and neurological cases and by 40-50% when treating gastrointestinal and dermatological cases. Workplace conditions need improvement as 34.8% of workplaces did not have isolation units for infected animals, 21.1% did not have separate eating areas for staff, and 57.1% did not have complete PPE kits for use. Veterinarians were more likely to use PPE if they had undertaken postgraduate education, perceived that zoonosis exposure from animals and procedures was likely, consciously considered PPE use for every case they dealt with and believed that liability issues and risks encouraged use of PPE. In contrast, those working in private practices, those who tended to 'just hope for the best' when trying to avoid zoonotic diseases, and those who were not aware of industry guidelines were less likely to use PPE. The results suggest that veterinarians' perceptions and workplace policies and culture substantially influence their use of PPE. Efforts should be made to encourage veterinarians and their workplaces to use infection control practices to protect themselves and their staff from zoonotic diseases. Copyright © 2013 Elsevier B.V. All rights reserved.
Kinematic control of male Allen's Hummingbird wing trill over a range of flight speeds.
Clark, Christopher J; Mistick, Emily A
2018-05-18
Wing trills are pulsed sounds produced by modified wing feathers at one or more specific points in time during a wingbeat. Male Allen's Hummingbird ( Selasphorus sasin ) produce a sexually dimorphic 9 kHz wing trill in flight. Here we investigate the kinematic basis for trill production. The wingtip velocity hypothesis posits that trill production is modulated by the airspeed of the wingtip at some point during the wingbeat, whereas the wing rotation hypothesis posits that trill production is instead modulated by wing rotation kinematics. To test these hypotheses, we flew six male Allen's Hummingbirds in an open jet wind tunnel at flight speeds of 0, 3, 6, 9, 12 and 14 m s -1 , and recorded their flight with two 'acoustic cameras' placed below and behind, or below and lateral to the flying bird. The acoustic cameras are phased arrays of 40 microphones that used beamforming to spatially locate sound sources within a camera image. Trill Sound Pressure Level (SPL) exhibited a U-shaped relationship with flight speed in all three camera positions. SPL was greatest perpendicular to the stroke plane. Acoustic camera videos suggest that the trill is produced during supination. The trill was up to 20 dB louder during maneuvers than it was during steady state flight in the wind tunnel, across all airspeeds tested. These data provide partial support for the wing rotation hypothesis. Altered wing rotation kinematics could allow male Allen's Hummingbird to modulate trill production in social contexts such as courtship displays. © 2018. Published by The Company of Biologists Ltd.
Polyphosphoester nanoparticles as biodegradable platform for delivery of multiple drugs and siRNA
Elzeny, Hadeel; Zhang, Fuwu; Ali, Esraa N; Fathi, Heba A; Zhang, Shiyi; Li, Richen; El-Mokhtar, Mohamed A; Hamad, Mostafa A; Wooley, Karen L; Elsabahy, Mahmoud
2017-01-01
Delivery of multiple therapeutics and/or diagnostic agents to diseased tissues is challenging and necessitates the development of multifunctional platforms. Among the various strategies for design of multifunctional nanocarriers, biodegradable polyphosphoester (PPE) polymers have been recently synthesized via a rapid and simple synthetic strategy. In addition, the chemical structure of the polymer could be tuned to form nanoparticles with varying surface chemistries and charges, which have shown exceptional safety and biocompatibility as compared to several commercial agents. The purpose of this study was to exploit a mixture of PPE nanoparticles of cationic and neutral surface charges for multiple delivery of anticancer drugs (ie, sorafenib and paclitaxel) and nucleic acids (ie, siRNA). Cationic PPE polymers could efficiently complex siRNA, and the stability of the nanoparticles could be maintained in physiological solutions and upon freeze-drying and were able to deliver siRNA in vivo when injected intravenously in mice. Commercially available cationic polyethylenimine polymer had LD50 of ca. 61.7 mg/kg in mice, whereas no animal died after injection of the cationic PPE polymer at a dose of >130 mg/kg. Neutral PPE nanoparticles were able to encapsulate two hydrophobic drugs, namely, sorafenib and paclitaxel, which are commonly used for the treatment of hepatocellular carcinoma. Mixing the neutral and cationic PPE nanoparticles did not result in any precipitation, and the size characteristics of both types of nanoparticles were maintained. Hence, PPE polymers might have potential for the delivery of multiple drugs and diagnostic agents to diseased tissues via simple synthesis of the individual polymers and assembly into nanoparticles that can host several drugs while being mixed in the same administration set, which is of importance for industrial and clinical development. PMID:28260861
Fujiki, Saori; Ishizaki, Tatsuro; Nakayama, Takeo
2017-12-01
Residents of long-term care facilities are highly susceptible to norovirus gastroenteritis, and each facility is concerned about the need to implement norovirus infection control. Among control measures, personal protective equipment (PPE), such as disposable gloves and masks, plays a major role in reducing infectious spread. However, the preparation status of PPE in facilities before infection outbreaks has not been reported. The aim was to clarify the implementation status of preventive measures for norovirus gastroenteritis and the cost of preparing the necessary PPE in long-term care facilities. A questionnaire survey of facilities affiliated with the Kyoto Prefecture and Osaka Prefecture branches of the Japan Association of Geriatric Health Services Facilities was conducted. The survey items were the characteristics of the facility, whether preventive measures had been implemented for norovirus gastroenteritis from October through the following March in both 2009 and 2010, and the quantities and unit prices of PPE prepared for preventive measures. Twenty-six (11.2%) of 232 surveyed facilities (as of August 2011) answered the survey. Among them, 24 (92.3%) in 2009 and 25 (96.2%) in 2010 reported having implemented preventive measures for norovirus gastroenteritis, while 21 facilities (80.8%) in 2009 and 22 facilities (84.6%) in 2010 had prepared PPE. The median total cost for preparing the PPE needed for the preventive measures was US $2601 (range US $221-9192) in 2009 and US $3904 (range US $305-6427) in 2010. Although the results need careful interpretation because of the low response rate, most of the surveyed long-term care facilities had implemented preventive measures for norovirus gastroenteritis. However, the cost of preparing the PPE needed for the preventive measures varied among the facilities. © 2017 John Wiley & Sons, Ltd.
Polyphosphoester nanoparticles as biodegradable platform for delivery of multiple drugs and siRNA.
Elzeny, Hadeel; Zhang, Fuwu; Ali, Esraa N; Fathi, Heba A; Zhang, Shiyi; Li, Richen; El-Mokhtar, Mohamed A; Hamad, Mostafa A; Wooley, Karen L; Elsabahy, Mahmoud
2017-01-01
Delivery of multiple therapeutics and/or diagnostic agents to diseased tissues is challenging and necessitates the development of multifunctional platforms. Among the various strategies for design of multifunctional nanocarriers, biodegradable polyphosphoester (PPE) polymers have been recently synthesized via a rapid and simple synthetic strategy. In addition, the chemical structure of the polymer could be tuned to form nanoparticles with varying surface chemistries and charges, which have shown exceptional safety and biocompatibility as compared to several commercial agents. The purpose of this study was to exploit a mixture of PPE nanoparticles of cationic and neutral surface charges for multiple delivery of anticancer drugs (ie, sorafenib and paclitaxel) and nucleic acids (ie, siRNA). Cationic PPE polymers could efficiently complex siRNA, and the stability of the nanoparticles could be maintained in physiological solutions and upon freeze-drying and were able to deliver siRNA in vivo when injected intravenously in mice. Commercially available cationic polyethylenimine polymer had LD 50 of ca. 61.7 mg/kg in mice, whereas no animal died after injection of the cationic PPE polymer at a dose of >130 mg/kg. Neutral PPE nanoparticles were able to encapsulate two hydrophobic drugs, namely, sorafenib and paclitaxel, which are commonly used for the treatment of hepatocellular carcinoma. Mixing the neutral and cationic PPE nanoparticles did not result in any precipitation, and the size characteristics of both types of nanoparticles were maintained. Hence, PPE polymers might have potential for the delivery of multiple drugs and diagnostic agents to diseased tissues via simple synthesis of the individual polymers and assembly into nanoparticles that can host several drugs while being mixed in the same administration set, which is of importance for industrial and clinical development.
Robinson, Nicola; Lorenc, Ava
2015-04-01
To explore barriers, challenges and best practice within patient and public engagement (PPE) in sexual and reproductive health and HIV (SRHH) services in London. Consultation exercise using qualitative interviews with 27 stakeholders including commissioners, managers, voluntary/community organizations (VCOs) clinicians and patients, analysed using Framework Analysis and Atlas.ti software. Participants recognized PPE's importance, echoing recent political and NHS drives, and highlighted the need for meaningful, empowering PPE, including user-designed methods, peer research and participatory approaches. Although challenging in SRHH and requiring training and support, PPE may help tackle stigma, and promote self-management and patient-centred-care, including peer education and role modelling. Expertise may come from experienced VCOs. Themes in priority order were: organizational commitment (including lack of dedicated staff, time and money); motivating patients; changing NHS philosophy; informing patients/public; using public awareness/education campaigns; overcoming stigma; working with VCOs. 'Reaching out' to engage underrepresented groups in this sensitive area was emphasized through community outreach, incentivization and linking with existing organizations. Making engagement easy and addressing issues of public value were also important. Stigma was less hindering than anticipated, except for ethnic minorities. PPE was seen to improve patient satisfaction, increase service uptake and reduce inequalities, key priorities in SRHH, and identify innovative service delivery ideas. PPE is crucial in creating a patient-led NHS and responsible society. If organizations, including the NHS, commit to implementing meaningful PPE which actively targets those at risk of poor SRHH, services can be truly patient-led and patients and communities empowered to tackle the stigma of SRHH. © 2012 John Wiley & Sons Ltd.
Understanding student concerns about peer physical examination using an activity theory framework.
Wearn, Andy M; Rees, Charlotte E; Bradley, Paul; Vnuk, Anna K
2008-12-01
Peer physical examination (PPE) has been employed for several decades as part of the formal curriculum for learning clinical skills. Most of the existing studies exploring students' attitudes towards PPE are single-site and use quantitative methods. Currently, there is a lack of theoretical underpinning to PPE as a learning method. Using an adaptation of the Examining Fellow Students questionnaire, we captured qualitative data from Year 1 medical students about their views and concerns around learning using PPE. The study was set in six schools across five countries (the UK, Australia, New Zealand, Japan and Hong Kong). Students provided free text comments that were later transcribed and analysed using framework analysis. A total of 617 students provided comments for analysis. This paper focuses on several related themes about the complexities of students' relationships within the context of PPE and their reflections on peer examination in comparison with genuine patient examination. Students drew parallels and differences between the peer examiner-examinee relationship and the doctor-patient relationship. They explained how these two types of relationship differed in nature and in terms of their levels of interaction. Our findings illuminate the interactional and complex nature of PPE, drawing out concerns and ambiguities around relationships, community and rules. We discuss our results in light of Engeström's model of activity theory (AT) and provide recommendations for educational practice and further research based on the principles of AT.
Webster-Gandy, Joan D; How, Chris; Harrold, Karen
2007-07-01
Palmar-plantar erythrodysesthesia (PPE) or hand-foot syndrome (HFS) is a relatively common side effect of cytotoxic chemotherapy. Many cytotoxic drugs have been reported to cause the condition but it is more frequently associated with 5 fluorouracil (5FU), liposomal doxorubicin and cytarabine. The oral 5FU precursor, capecitabine is frequently associated with PPE and with the recent extension of its use to adjuvant treatment, the incidence of PPE is likely to increase. The initial symptoms are dysesthesia and tingling in the palms, fingers and soles of feet and erythema, which may progress to burning pain with dryness, cracking, desquamation, ulceration and oedema. Palms of the hands are more frequently affected than soles of the feet. This condition is painful and distressing to patients and in some incidences it results in patients not being able to work or perform normal daily activities. It can also result in treatment interruptions which impact on the efficacy of the treatment regimen. Effective and appropriate patient education from a specialist nurse prior to treatment is an essential part of patient management which will facilitate early identification of the symptoms and therefore prevent treatment delays and PPE progression. This article reviews current knowledge of the condition, including classification, and discussion of the findings of a clinical audit in a cancer centre. It includes the incidence, grading, management and impact of PPE on normal daily activities.
Sun, Yi; Tian, Yuke; Li, Haifeng; Zhang, Dengwen; Sun, Qiang
2017-01-01
Background . This study aimed to investigate the use of human bone marrow mesenchymal stem cells (hBMSCs) genetically engineered with the human proenkephalin (hPPE) gene to treat bone cancer pain (BCP) in a rat model. Methods . Primary cultured hBMSCs were passaged and modified with hPPE, and the cell suspensions (6 × 10 6 ) were then intrathecally injected into a rat model of BCP. Paw mechanical withdrawal threshold (PMWT) was measured before and after BCP. The effects of hPPE gene transfer on hBMSC bioactivity were analyzed in vitro and in vivo. Results . No changes were observed in the surface phenotypes and differentiation of hBMSCs after gene transfer. The hPPE-hBMSC group showed improved PMWT values on the ipsilateral side of rats with BCP from day 12 postoperatively, and the analgesic effect was reversed by naloxone. The levels of proinflammatory cytokines such as IL-1 β and IL-6 were ameliorated, and leucine-enkephalin (L-EK) secretion was augmented, in the hPPE-engineered hBMSC group. Conclusion . The intrathecal administration of BMSCs modified with the hPPE gene can effectively relieve pain caused by bone cancer in rats and might be a potentially therapeutic tool for cancer-related pain in humans.
Ates, Louis S.; van der Woude, Aniek D.; Bestebroer, Jovanka; van Stempvoort, Gunny; Musters, René J. P.; Garcia-Vallejo, Juan J.; Picavet, Daisy I.; van de Weerd, Robert; Maletta, Massimiliano; Kuijl, Coenraad P.; van der Wel, Nicole N.; Bitter, Wilbert
2016-01-01
Mycobacteria produce a capsule layer, which consists of glycan-like polysaccharides and a number of specific proteins. In this study, we show that, in slow-growing mycobacteria, the type VII secretion system ESX-5 plays a major role in the integrity and stability of the capsule. We have identified PPE10 as the ESX-5 substrate responsible for this effect. Mutants in esx-5 and ppe10 both have impaired capsule integrity as well as reduced surface hydrophobicity. Electron microscopy, immunoblot and flow cytometry analyses demonstrated reduced amounts of surface localized proteins and glycolipids, and morphological differences in the capsular layer. Since capsular proteins secreted by the ESX-1 system are important virulence factors, we tested the effect of the mutations that cause capsular defects on virulence mechanisms. Both esx-5 and ppe10 mutants of Mycobacterium marinum were shown to be impaired in ESX-1-dependent hemolysis. In agreement with this, the ppe10 and esx5 mutants showed reduced recruitment of ubiquitin in early macrophage infection and intermediate attenuation in zebrafish embryos. These results provide a pivotal role for the ESX-5 secretion system and its substrate PPE10, in the capsular integrity of pathogenic mycobacteria. These findings open up new roads for research on the mycobacterial capsule and its role in virulence and immune modulation. PMID:27280885
Al Zadjali, Said; Morse, Stephen; Chenoweth, Jonathan; Deadman, Mike
2015-01-01
The level of uptake and use of personal protective equipment (PPE) by farm workers in Oman is low; the conditions under which pesticides are stored are frequently below acceptable international standards. Research was undertaken to explore the drivers working against safe storage of agrochemicals and effective personal protection usage by pesticide application personnel. Results from a survey of over 200 respondents, representing workers in, and owners of, farms either within or outside a local farmer's association (FA), suggest that FA membership raises standards of behaviour both in terms of safe pesticide storage and use of PPE. Age of respondents had no apparent effect on the likelihood of PPE (gloves and masks) use. PPE use was, however, highest among respondents with more advanced educational backgrounds. Positive responses for glove and mask use, when applying pesticides, were higher for owners and workers in FA farms compared to non-FA farms. Lowest reported use of PPE was among workers in non-FA farms. Analysis of responses appears to indicate that behaviour patterns of workers in FA farms mirror that of the farm owners. This was not the case in non-FA farms. The results suggest that conformity to social norms, in this case acceptable work-environment behaviour, is a powerful driver behind raised usage levels of PPE in farms in Oman. Copyright © 2014 Elsevier B.V. All rights reserved.
Wernick, B; Cipriano, A; Odom, S R; MacBean, U; Mubang, R N; Wojda, T R; Liu, S; Serres, S; Evans, D C; Thomas, P G; Cook, C H; Stawicki, S P
2017-06-01
The spleen is one of the most commonly injured abdominal solid organs during blunt trauma. Modern management of splenic trauma has evolved to include non-operative therapies, including observation and angioembolization to preclude splenectomy in most cases of blunt splenic injury. Despite the shift in management strategies, relatively little is known about the hematologic changes associated with these various modalities. The aim of this study was to determine if there are significant differences in hematologic characteristics over time based on the treatment modality employed following splenic trauma. We hypothesized that alterations seen in hematologic parameters would vary between observation (OBS), embolization (EMB), and splenectomy (SPL) in the setting of splenic injury. An institutional review board-approved, retrospective study of routine hematologic indices examined data between March 2000 and December 2014 at three academic trauma centers. A convenience sample of patients with splenic trauma and admission lengths of stay >96 h was selected for inclusion, resulting in a representative sample of each sub-group (OBS, EMB, and SPL). Basic demographics and injury severity data (ISS) were abstracted. Platelet count, red blood cell (RBC) count and RBC indices, and white blood cell (WBC) count with differential were analyzed between the time of admission and a maximum of 1080 h (45 days) post-injury. Comparisons between OBS, EMB, and SPL groups were then performed using non-parametric statistical testing, with statistical significance set at p < 0.05. Data from 130 patients (40 SPL, 40 EMB, and 50 OBS) were analyzed. The median age was 40 years, with 67 % males. Median ISS was 21.5 (21 for SPL, 19 for EMB, and 22 for OBS, p = n/s) and median Glasgow Coma Scale (GCS) was 15. Median splenic injury grade varied by interventional modality (grade 4 for SPL, 3 for EMB, and 2 for OBS, p < 0.05). Inter-group comparisons demonstrated no significant differences in RBC counts. However, mean corpuscular volume (MCV) and RBC distribution width (RDW) were elevated in the SPL and EMB groups (p < 0.01). Similarly, EMB and SPL groups had higher platelet counts than the OBS group (p < 0.01). In aggregate, WBC counts were highest following SPL, followed by EMB and OBS (p < 0.01). Similar trends were noted in neutrophil and monocyte counts (p < 0.01), but not in lymphocyte counts (p = n/s). This study describes important trends and patterns among fundamental hematologic parameters following traumatic splenic injuries managed with SPL, EMB, or OBS. As expected, observed WBC counts were highest following SPL, then EMB, and finally OBS. No differences were noted in RBC count between the three groups, but RDW was significantly greater following SPL compared to EMB and OBS. We also found that MCV was highest following OBS, when compared to EMB or SPL. Finally, our data indicate that platelet counts are similarly elevated for both SPL and EMB, when compared to the OBS group. These results provide an important foundation for further research in this still relatively unexplored area.
Carek, P J; Hunter, L
2001-01-01
The preparticipation physical examination (PPE) has become the standard of care for the millions of high school students in the United States as they prepare for athletic participation. These assessments are intended to identify medical conditions that may affect safe and effective participation in organized sports. The PPE has become an integral aspect of the athletic and sports medicine system during the last three decades. Over time, the PPE has been revised, largely based upon the recommendations of large medical organizations. Several primary and secondary goals have been presented to be accomplished through the PPE. One particular goal of these assessments is to identify individuals with underlying cardiovascular disease, a significant cause of acute sudden cardiac death in high school and college athletes. While current research continues to demonstrate that the PPE has no effect on the overall morbidity and mortality rates in athletes, other objectives may be fulfilled by these examinations. In order to improve the ability of these examinations in fulfilling their primary objectives, instruments that have better results in preventing the injuries and deaths associated with athletic participation should be developed and investigate.
Cardoso, Ronie Cleverson; Lobão-Soares, Bruno; Bianchin, Marino Muxfeldt; Carlotti, Carlos Gilberto; Walz, Roger; Alvarez-Silva, Márcio; Trentin, Andréa Gonçalves; Nicolau, Mauro
2004-01-01
Background While it is well known that bradykinin B2 agonists increase plasma protein extravasation (PPE) in brain tumors, the bradykinin B1 agonists tested thus far are unable to produce this effect. Here we examine the effect of the selective B1 agonist bradykinin (BK) Sar-[D-Phe8]des-Arg9BK (SAR), a compound resistant to enzymatic degradation with prolonged activity on PPE in the blood circulation in the C6 rat glioma model. Results SAR administration significantly enhanced PPE in C6 rat brain glioma compared to saline or BK (p < 0.01). Pre-administration of the bradykinin B1 antagonist [Leu8]-des-Arg (100 nmol/Kg) blocked the SAR-induced PPE in the tumor area. Conclusions Our data suggest that the B1 receptor modulates PPE in the blood tumor barrier of C6 glioma. A possible role for the use of SAR in the chemotherapy of gliomas deserves further study. PMID:15458573
Preparticipation screening - the sports physical therapy perspective.
Sanders, Barbara; Blackburn, Turner A; Boucher, Brenda
2013-04-01
The sports physical therapist (SPT) is uniquely qualified to participate in the provision of preparticipation physical examinations (PPE). The PPE is recommended prior to athletic participation and required by many jurisdictions. There is little research to support the process and components; however, a number of professional organizations have recommendations that direct the PPE process. This clinical commentary highlights the role of the sports physical therapist and current evidence related to the preparticipation physical examination process. Data sources were limited to include professional positions and peer reviewed publications from 1988 through January 2013. Preparticipation physicals should be useful, comprehensive, and cost effective for the athlete and the health care team. Additional research is indicated in many of the areas of the PPE. The SPT is a valuable member of the health care team and can be a primary facilitator of the PPE in concert with the physician, athletic trainer, athletic organization administrators, and others. Well-designed and inclusive PPEs can be provided to meet the major objectives of identification of athletes at risk. Controversy continues over the extent of the cardiac screening component as well as other sport or athlete specific components. 5.
2011-01-01
Background In Drosophila, the Enhancer of split complex (E(spl)-C) comprises 11 bHLH and Bearded genes that function during Notch signaling to repress proneural identity in the developing peripheral nervous system. Comparison with other insects indicates that the basal state for Diptera is a single bHLH and Bearded homolog and that the expansion of the gene complex occurred in the lineage leading to Drosophila. However, comparative genomic data from other fly species that would elucidate the origin and sequence of gene duplication for the complex is lacking. Therefore, in order to examine the evolutionary history of the complex within Diptera, we reconstructed, using several fosmid clones, the entire E(spl)-complex in the stalk-eyed fly, Teleopsis dalmanni and collected additional homologs of E(spl)-C genes from searches of dipteran EST databases and the Glossina morsitans genome assembly. Results Comparison of the Teleopsis E(spl)-C gene organization with Drosophila indicates complete conservation in gene number and orientation between the species except that T. dalmanni contains a duplicated copy of E(spl)m5 that is not present in Drosophila. Phylogenetic analysis of E(spl)-complex bHLH and Bearded genes for several dipteran species clearly demonstrates that all members of the complex were present prior to the diversification of schizophoran flies. Comparison of upstream regulatory elements and 3' UTR domains between the species also reveals strong conservation for many of the genes and identifies several novel characteristics of E(spl)-C regulatory evolution including the discovery of a previously unidentified, highly conserved SPS+A domain between E(spl)mγ and E(spl)mβ. Conclusion Identifying the phylogenetic origin of E(spl)-C genes and their associated regulatory DNA is essential to understanding the functional significance of this well-studied gene complex. Results from this study provide numerous insights into the evolutionary history of the complex and will help refine the focus of studies examining the adaptive consequences of this gene expansion. PMID:22151427
Comparison of forcefields for molecular dynamics simulations of hydrocarbon phase diagrams
NASA Astrophysics Data System (ADS)
Pisarev, V. V.; Zakharov, S. A.
2018-01-01
Molecular dynamics calculations of vapor-liquid equilibrium of methane-n-butane mixture are performed. Three force-field models are tested: the TraPPE-UA united-atom forcefield, LOPLS-AA all-atom forcefield and a fully flexible version of the TraPPE-EH all-atom forcefield. All those forcefields reproduce well the composition of liquid phase in the mixture as a function of pressure at the 300 K isotherm, while significant discrepancies from experimental data are observed in the saturated vapor compositions with OPLS-AA and TraPPE-UA forcefields. The best agreement with the experimental phase diagram is found with TraPPE-EH forcefield which accurately reproduces compositions of both liquid and vapor phase. This forcefield can be recommended for simulation of two-phase hydrocarbon systems.
2017-06-18
To observe the morphological changes on cochlear hair cells of rats in simulated weightlessness and inboard noise and to investigate the different changes in three turns of hair cells. Thirty-two healthy SD rats, all males, were randomly divided into four groups: control group, weightlessness group, noise group and weightlessness+noise groups (n=8). Then rats were exposed to -30° head down tilt as simulated weightlessness and inboard noise including steady-state noise which was (72±2) dB SPL and impulse noise up to 160 dB SPL in spaceship environment. The control group was kept in normal condition for 8 weeks. Bilateral auditory brainstem response (ABR) thresholds were tested before and after exposure respectively, and immunofluorescence staining and scanning electron microscopy (SEMs) of basilar membrane were applied after exposure. ABR threshold shifts of each group were higher after exposure. There was difference between ABRs of the experiment groups before and after exposure (P<0.05). IF showed that the inner hair cells (IHCs) missing was the main damage in the basal turn of weightlessness group, the hair cells in the middle turn were swell and in the top turn, the hair cells were not clear. In noise group, the main loss happened in the outer hair cells (OHCs) of the outermost layer. In weightlessness+noise group, the nuclear missing in the basal turn was apparent, and mainly happened at the outermost layer. Meanwhile, the missing of hair cells in the middle turn and top turn was seen at the innermost layer. SEM showed that the cilia in the basal turn of weightlessness group were serious lodging, and occasional absence. Furthermore, the basal cilia in noise group became lodged and absent, and the other two turns were seriously missing. And in weightlessness+noise group, the cilia missing in the basal turn was apparently seen. The damage degree of the four groups: weightlessness+noise group>noise group>weightlessness group>control group and the damage degree of the four turns of hair cells: basal turn>mid turn>top turn. The rats exposed to the above environment for 2 weeks displayed obvious changes in cochlea morphology, and the weightlessness +noise group had the most obvious damage.
Optical measurement of the weak non-linearity in the eardrum vibration response to auditory stimuli
NASA Astrophysics Data System (ADS)
Aerts, Johan
The mammalian hearing organ consists of the external ear (auricle and ear canal) followed by the middle ear (eardrum and ossicles) and the inner ear (cochlea). Its function is to convert the incoming sound waves and convert them into nerve pulses which are processed in the final stage by the brain. The main task of the external and middle ear is to concentrate the incoming sound waves on a smaller surface to reduce the loss that would normally occur in transmission from air to inner ear fluid. In the past it has been shown that this is a linear process, thus without serious distortions, for sound waves going up to pressures of 130 dB SPL (˜90 Pa). However, at large pressure changes up to several kPa, the middle ear movement clearly shows non-linear behaviour. Thus, it is possible that some small non-linear distortions are also present in the middle ear vibration at lower sound pressures. In this thesis a sensitive measurement set-up is presented to detect this weak non-linear behaviour. Essentially, this set-up consists of a loud-speaker which excites the middle ear, and the resulting vibration is measured with an heterodyne vibrometer. The use of specially designed acoustic excitation signals (odd random phase multisines) enables the separation of the linear and non-linear response. The application of this technique on the middle ear demonstrates that there are already non-linear distortions present in the vibration of the middle ear at a sound pressure of 93 dB SPL. This non-linear component also grows strongly with increasing sound pressure. Knowledge of this non-linear component can contribute to the improvement of modern hearing aids, which operate at higher sound pressures where the non-linearities could distort the signal considerably. It is also important to know the contribution of middle ear non-linearity to otoacoustic emissions. This are non-linearities caused by the active feedback amplifier in the inner ear, and can be detected in the external and middle ear. These signals are used for diagnostic purposes, and therefore it is important to have an estimate the non-linear middle ear contribution to these emissions.
The Middle Ear Muscle Reflex in Rat: Developing a Biomarker of Auditory Nerve Degeneration.
Chertoff, Mark E; Martz, Ashley; Sakumura, Joey T; Kamerer, Aryn M; Diaz, Francisco
The long-term goal of this research is to determine whether the middle ear muscle reflex can be used to predict the number of healthy auditory nerve fibers in hearing-impaired ears. In this study, we develop a high-impedance source and an animal model of the middle ear muscle reflex and explore the influence of signal frequency and level on parameters of the reflex to determine an optimal signal to examine auditory nerve fiber survival. A high-impedance source was developed using a hearing aid receiver attached to a 0.06 diameter 10.5-cm length tube. The impedance probe consisted of a microphone probe placed near the tip of a tube coupled to a sound source. The probe was calibrated by inserting it into a syringe of known volumes and impedances. The reflex in the anesthetized rat was measured with elicitor stimuli ranging from 3 to 16 kHz presented at levels ranging from 35 to 100 dB SPL to one ear while the reflex was measured in the opposite ear containing the probe and probe stimulus. The amplitude of the reflex increased with elicitor level and was largest at 3 kHz. The lowest threshold was approximately 54 dB SPL for the 3-kHz stimulus. The rate of decay of the reflex was greatest at 16 kHz followed by 10 and 3 kHz. The rate of decay did not change significantly with elicitor signal level for 3 and 16 kHz, but decreased as the level of the 10-kHz elicitor increased. A negative feedback model accounts for the reflex decay by having the strength of feedback dependent on auditory nerve input. The rise time of the reflex varied with frequency and changed with level for the 10- and 16-kHz signals but not significantly for the 3-kHz signal. The latency of the reflex increased with a decrease in elicitor level, and the change in latency with level was largest for the 10-kHz stimulus. Because the amplitude of the reflex in rat was largest with an elicitor signal at 3 kHz, had the lowest threshold, and yielded the least amount of decay, this may be the ideal frequency to estimate auditory nerve survival in hearing-impaired ears.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-06
... follows: ``Chronic Toxicity Test of SPL in Rats'' (Fujino, et al.) (Ref. 2); ``Acute and Subacute Toxicity Tests of SPL'' (Fujino, et al.) (mice and rats) (Ref. 3); ``Teratologenicity Study of SPL in Rats and... Inoculation with Herpes Simplex Virus'' (Department of Microbiology, School of Medicine, Kyushu University...
75 FR 5144 - Submission for OMB Review: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-01
... of a previously approved collection. Title of Collection: Personal Protective Equipment (PPE) for... of the workplace to determine if personal protective equipment (PPE) is necessary and to communicate...
2016-08-01
ANTHROPOMETRICS AND BODY SIZE CHANGES ON THE DEVELOPMENT OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SIZING SYSTEMS IN THE US ARMY by Hyeg Joo Choi* Todd...EFFECTS OF ANTHROPOMETRICS AND BODY SIZE CHANGES ON THE DEVELOPMENT OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SIZING SYSTEMS IN THE US ARMY 5a. CONTRACT...Universities (ORAU) Maryland, 4692 Millennium Drive, Suite 101, Belcamp, MD 21017 14. ABSTRACT Understanding body size and shape information of military
Salgado-Pabon, Wilmara; Meyerholz, David K.; White, Mark J.; Schlievert, Patrick M.
2016-01-01
ABSTRACT The Spl proteases are a group of six serine proteases that are encoded on the νSaβ pathogenicity island and are unique to Staphylococcus aureus. Despite their interesting biochemistry, their biological substrates and functions in virulence have been difficult to elucidate. We found that an spl operon mutant of the community-associated methicillin-resistant S. aureus USA300 strain LAC induced localized lung damage in a rabbit model of pneumonia, characterized by bronchopneumonia observed histologically. Disease in the mutant-infected rabbits was restricted in distribution compared to that in wild-type USA300-infected rabbits. We also found that SplA is able to cleave the mucin 16 glycoprotein from the surface of the CalU-3 lung cell line, suggesting a possible mechanism for wild-type USA300 spreading pneumonia to both lungs. Investigation of the secreted and surface proteomes of wild-type USA300 and the spl mutant revealed multiple alterations in metabolic proteins and virulence factors. This study demonstrates that the Spls modulate S. aureus physiology and virulence, identifies a human target of SplA, and suggests potential S. aureus targets of the Spl proteases. IMPORTANCE Staphylococcus aureus is a versatile human pathogen that produces an array of virulence factors, including several proteases. Of these, six proteases called the Spls are the least characterized. Previous evidence suggests that the Spls are expressed during human infection; however, their function is unknown. Our study shows that the Spls are required for S. aureus to cause disseminated lung damage during pneumonia. Further, we present the first example of a human protein cut by an Spl protease. Although the Spls were predicted not to cut staphylococcal proteins, we also show that an spl mutant has altered abundance of both secreted and surface-associated proteins. This work provides novel insight into the function of Spls during infection and their potential ability to degrade both staphylococcal and human proteins. PMID:27747296
Virucidal activity of the dendrimer microbicide SPL7013 against HIV-1.
Telwatte, Sushama; Moore, Katie; Johnson, Adam; Tyssen, David; Sterjovski, Jasminka; Aldunate, Muriel; Gorry, Paul R; Ramsland, Paul A; Lewis, Gareth R; Paull, Jeremy R A; Sonza, Secondo; Tachedjian, Gilda
2011-06-01
Topical microbicides for use by women to prevent the transmission of human immunodeficiency virus (HIV) and other sexually transmitted infections are urgently required. Dendrimers are highly branched nanoparticles being developed as microbicides. SPL7013 is a dendrimer with broad-spectrum activity against HIV type I (HIV-1) and -2 (HIV-2), herpes simplex viruses type-1 (HSV-1) and -2 (HSV-2) and human papillomavirus. SPL7013 [3% (w/w)] has been formulated in a mucoadhesive carbopol gel (VivaGel®) for use as a topical microbicide. Previous studies showed that SPL7013 has similar potency against CXCR4-(X4) and CCR5-using (R5) strains of HIV-1 and that it blocks viral entry. However, the ability of SPL7013 to directly inactivate HIV-1 is unknown. We examined whether SPL7013 demonstrates virucidal activity against X4 (NL4.3, MBC200, CMU02 clade EA and 92UG046 clade D), R5 (Ba-L, NB25 and 92RW016 clade A) and dual-tropic (R5X4; MACS1-spln) HIV-1 using a modified HLA-DR viral capture method and by polyethylene glycol precipitation. Evaluation of virion integrity was determined by ultracentrifugation through a sucrose cushion and detection of viral proteins by Western blot analysis. SPL7013 demonstrated potent virucidal activity against X4 and R5X4 strains, although virucidal activity was less potent for the 92UG046 X4 clade D isolate. Where potent virucidal activity was observed, the 50% virucidal concentrations were similar to the 50% effective concentrations previously reported in drug susceptibility assays, indicating that the main mode of action of SPL7013 is by direct viral inactivation for these strains. In contrast, SPL7013 lacked potent virucidal activity against R5 HIV-1 strains. Evaluation of the virucidal mechanism showed that SPL7013-treated NL4.3, 92UG046 and MACS1-spln virions were intact with no significant decrease in gp120 surface protein with respect to p24 capsid content compared to the corresponding untreated virus. These studies demonstrate that SPL7013 is virucidal against HIV-1 strains that utilize the CXCR4 coreceptor but not viruses tested in this study that solely use CCR5 by a mechanism that is distinct from virion disruption or loss of gp120. In addition, the mode of action by which SPL7013 prevents infection of cells with X4 and R5X4 strains is likely to differ from R5 strains of HIV-1. Copyright © 2011 Elsevier B.V. All rights reserved.
Watkins, Greg D; Swanson, Brett A; Suaning, Gregg J
2018-02-22
Cochlear implant (CI) sound processing strategies are usually evaluated in clinical studies involving experienced implant recipients. Metrics which estimate the capacity to perceive speech for a given set of audio and processing conditions provide an alternative means to assess the effectiveness of processing strategies. The aim of this research was to assess the ability of the output signal to noise ratio (OSNR) to accurately predict speech perception. It was hypothesized that compared with the other metrics evaluated in this study (1) OSNR would have equivalent or better accuracy and (2) OSNR would be the most accurate in the presence of variable levels of speech presentation. For the first time, the accuracy of OSNR as a metric which predicts speech intelligibility was compared, in a retrospective study, with that of the input signal to noise ratio (ISNR) and the short-term objective intelligibility (STOI) metric. Because STOI measured audio quality at the input to a CI sound processor, a vocoder was applied to the sound processor output and STOI was also calculated for the reconstructed audio signal (vocoder short-term objective intelligibility [VSTOI] metric). The figures of merit calculated for each metric were Pearson correlation of the metric and a psychometric function fitted to sentence scores at each predictor value (Pearson sigmoidal correlation [PSIG]), epsilon insensitive root mean square error (RMSE*) of the psychometric function and the sentence scores, and the statistical deviance of the fitted curve to the sentence scores (D). Sentence scores were taken from three existing data sets of Australian Sentence Tests in Noise results. The AuSTIN tests were conducted with experienced users of the Nucleus CI system. The score for each sentence was the proportion of morphemes the participant correctly repeated. In data set 1, all sentences were presented at 65 dB sound pressure level (SPL) in the presence of four-talker Babble noise. Each block of sentences used an adaptive procedure, with the speech presented at a fixed level and the ISNR varied. In data set 2, sentences were presented at 65 dB SPL in the presence of stationary speech weighted noise, street-side city noise, and cocktail party noise. An adaptive ISNR procedure was used. In data set 3, sentences were presented at levels ranging from 55 to 89 dB SPL with two automatic gain control configurations and two fixed ISNRs. For data set 1, the ISNR and OSNR were equally most accurate. STOI was significantly different for deviance (p = 0.045) and RMSE* (p < 0.001). VSTOI was significantly different for RMSE* (p < 0.001). For data set 2, ISNR and OSNR had an equivalent accuracy which was significantly better than that of STOI for PSIG (p = 0.029) and VSTOI for deviance (p = 0.001), RMSE*, and PSIG (both p < 0.001). For data set 3, OSNR was the most accurate metric and was significantly more accurate than VSTOI for deviance, RMSE*, and PSIG (all p < 0.001). ISNR and STOI were unable to predict the sentence scores for this data set. The study results supported the hypotheses. OSNR was found to have an accuracy equivalent to or better than ISNR, STOI, and VSTOI for tests conducted at a fixed presentation level and variable ISNR. OSNR was a more accurate metric than VSTOI for tests with fixed ISNRs and variable presentation levels. Overall, OSNR was the most accurate metric across the three data sets. OSNR holds promise as a prediction metric which could potentially improve the effectiveness of sound processor research and CI fitting.
Structured product labeling improves detection of drug-intolerance issues.
Schadow, Gunther
2009-01-01
This study sought to assess the value of the Health Level 7/U.S. Food and Drug Administration Structured Product Labeling (SPL) drug knowledge representation standard and its associated terminology sources for drug-intolerance (allergy) decision support in computerized provider order entry (CPOE) systems. The Regenstrief Institute CPOE drug-intolerance issue detection system and its knowledge base was compared with a method based on existing SPL label content enriched with knowledge sources used with SPL (NDF-RT/MeSH). Both methods were applied to a large set of drug-intolerance (allergy) records, drug orders, and medication dispensing records covering >50,000 patients over 30 years. The number of drug-intolerance issues detected by both methods was counted, as well as the number of patients with issues, number of distinct drugs, and number of distinct intolerances. The difference between drug-intolerance issues detected or missed by either method was qualitatively analyzed. Although <70% of terms were mapped to SPL, the new approach detected four times as many drug-intolerance issues on twice as many patients. The SPL-based approach is more sensitive and suggests that mapping local dictionaries to SPL, and enhancing the depth and breadth of coverage of SPL content are worth accelerating. The study also highlights specificity problems known to trouble drug-intolerance decision support and suggests how terminology and methods of recording drug intolerances could be improved.
Chen, Guang-Hui; Sun, Jia-Ying; Liu, Man; Liu, Jie; Yang, Wei-Cai
2014-12-20
Germlines in plants are formed de novo during post-embryonic development, while little is known about the mechanism that controls this process. In Arabidopsis, the earliest gene controlling this process is SPOROCYTELESS (SPL). A decade ago, we showed that loss of SPL function abolished sporogenesis in both male and female organs of Arabidopsis. However, its function is unclear up to now. In this study, we showed that SPL belongs to a novel transcription repressor family specific in embryophyte, which consists of 173 members in the land plants so far. All of them contain a conserved SPL-motif in their N-terminal and an ethylene-responsive element binding factor-associated amphiphilic repression (EAR) motif in the C-terminal, therefore designated as SPL-like, EAR-containing proteins (SPEARs). Consistently, SPL acts as a transcriptional repressor in yeast and tobacco cells, and SPEAR proteins are able to form homodimer and/or heterodimer with each other in vitro. Furthermore, SPEARs interact with the TOPLESS (TPL) co-repressors via the EAR motif and TCP family transcription factors in yeast cells. Together, we propose that SPL and SPEARs most likely belong to a novel transcription repressor family in land plants which may play a variety of developmental roles in plants. Copyright © 2014 Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, and Genetics Society of China. Published by Elsevier Ltd. All rights reserved.
Han, Song-Hee; Kim, Sung-June; Yun, Young Won; Nam, Sang Yoon; Lee, Hu-Jang; Lee, Beom-Jun
2018-03-01
This study was performed to investigate the effect of a concentrate of fermented wild ginseng root culture (HLJG0701) on memory improvement in the scopolamine (SPL)-induced memory-deficient mouse model. Eight-week-old male ICR mice were used to evaluate the protective effect of HLJG0701 against the SPL-induced memory loss animal model. The Morris water maze test, which measures hippocampus-dependent learning ability, and the Y-maze test, a short-term memory assessment test, were performed and related markers were analyzed. HLJG0701-treated groups displayed significantly reduced acetylcholinesterase activity and increased acetylcholine level compared with the SPL-administered group (SPL-G) ( P <0.05). In the Y-maze test, the spontaneous alternation in al HLJG0711-treated groups was significantly increased compared with that in SPL-G ( P <0.05). In the Morris water maze test, the escape latency and time spent in the target quadrant in all HLJG0701-treated groups were significantly decreased and increased, respectively, compared with those in SPL-G ( P <0.05). In addition, the brain-derived neurotrophic factor level in groups treated with HLJG0701 300 and 600 mg/kg body weight was significantly increased compared with that in SPL-G ( P <0.05). These results suggest that the HLJG0701 may protect against memory loss by inhibiting acetylcholinesterase activity and preventing acetylcholine deficiency.
Structured Product Labeling Improves Detection of Drug-intolerance Issues
Schadow, Gunther
2009-01-01
Objectives This study sought to assess the value of the Health Level 7/U.S. Food and Drug Administration Structured Product Labeling (SPL) drug knowledge representation standard and its associated terminology sources for drug-intolerance (allergy) decision support in computerized provider order entry (CPOE) systems. Design The Regenstrief Institute CPOE drug-intolerance issue detection system and its knowledge base was compared with a method based on existing SPL label content enriched with knowledge sources used with SPL (NDF-RT/MeSH). Both methods were applied to a large set of drug-intolerance (allergy) records, drug orders, and medication dispensing records covering >50,000 patients over 30 years. Measurements The number of drug-intolerance issues detected by both methods was counted, as well as the number of patients with issues, number of distinct drugs, and number of distinct intolerances. The difference between drug-intolerance issues detected or missed by either method was qualitatively analyzed. Results Although <70% of terms were mapped to SPL, the new approach detected four times as many drug-intolerance issues on twice as many patients. Conclusion The SPL-based approach is more sensitive and suggests that mapping local dictionaries to SPL, and enhancing the depth and breadth of coverage of SPL content are worth accelerating. The study also highlights specificity problems known to trouble drug-intolerance decision support and suggests how terminology and methods of recording drug intolerances could be improved. PMID:18952933
29 CFR 1910.9 - Compliance duties owed to each employee.
Code of Federal Regulations, 2010 CFR
2010-07-01
... employee. (a) Personal protective equipment. Standards in this part requiring the employer to provide personal protective equipment (PPE), including respirators and other types of PPE, because of hazards to...
29 CFR 1910.9 - Compliance duties owed to each employee.
Code of Federal Regulations, 2011 CFR
2011-07-01
... employee. (a) Personal protective equipment. Standards in this part requiring the employer to provide personal protective equipment (PPE), including respirators and other types of PPE, because of hazards to...
29 CFR 1917.5 - Compliance duties owed to each employee.
Code of Federal Regulations, 2010 CFR
2010-07-01
... employee. (a) Personal protective equipment. Standards in this part requiring the employer to provide personal protective equipment (PPE), including respirators and other types of PPE, because of hazards to...
29 CFR 1917.5 - Compliance duties owed to each employee.
Code of Federal Regulations, 2011 CFR
2011-07-01
... employee. (a) Personal protective equipment. Standards in this part requiring the employer to provide personal protective equipment (PPE), including respirators and other types of PPE, because of hazards to...
Measurement of impulse peak insertion loss for four hearing protection devices in field conditions
Murphy, William J.; Flamme, Gregory A.; Meinke, Deanna K.; Sondergaard, Jacob; Finan, Donald S.; Lankford, James E.; Khan, Amir; Vernon, Julia; Stewart, Michael
2015-01-01
Objective In 2009, the U.S. Environmental Protection Agency (EPA) proposed an impulse noise reduction rating (NRR) for hearing protection devices based upon the impulse peak insertion loss (IPIL) methods in the ANSI S12.42-2010 standard. This study tests the ANSI S12.42 methods with a range of hearing protection devices measured in field conditions. Design The method utilizes an acoustic test fixture and three ranges for impulse levels: 130–134, 148–152, and 166–170 dB peak SPL. For this study, four different models of hearing protectors were tested: Bilsom 707 Impact II electronic earmuff, E·A·R Pod Express, E·A·R Combat Arms version 4, and the Etymotic Research, Inc. Electronic BlastPLG™ EB1. Study sample Five samples of each protector were fitted on the fixture or inserted in the fixture's ear canal five times for each impulse level. Impulses were generated by a 0.223 caliber rifle. Results The average IPILs increased with peak pressure and ranged between 20 and 38 dB. For some protectors, significant differences were observed across protector examples of the same model, and across insertions. Conclusions The EPA's proposed methods provide consistent and reproducible results. The proposed impulse NRR rating should utilize the minimum and maximum protection percentiles as determined by the ANSI S12.42-2010 methods. PMID:22176308
Re-examination of the role of the human acoustic stapedius reflex
NASA Astrophysics Data System (ADS)
Phillips, Dennis P.; Stuart, Andrew; Carpenter, Michael
2002-05-01
The ``rollover'' seen in the word recognition performance scores of patients with Bell's palsy (facial nerve paralysis) has historically been taken as an indicator of the role of the stapedius reflex in the protection from upward spread of masking. Bell's palsy, however, may be a polyneuropathy, so it is not clear that the poor word recognition performance at high levels is necessarily attributable specifically to impaired facial nerve function. The present article reports two new experiments that probe whether an isolated impairment of the stapedius reflex can produce rollover in word recognition performance-intensity functions. In experiment 1, performance-intensity functions for monosyllabic speech materials were obtained from ten normal listeners under two listening conditions: normal and low-frequency augmented to offset the effects of the stapedius reflex on the transmission of low-frequency vibrations to the cochlea. There was no effect of the spectral augmentation on word recognition for stimulus levels up to 107 dB SPL. In experiment 2, six patients who had undergone stapedectomy were tested for rollover using performance-intensity functions. None of the patients showed rollover in their performance-intensity functions, even at stimulus levels in excess of 100 dB HL. These data suggest that if the stapedius reflex has a role in protection from upward spread of masking, then this role is inconsequential for word recognition in quiet.
Growth of suppression in humans based on distortion-product otoacoustic emission measurements
Gorga, Michael P.; Neely, Stephen T.; Kopun, Judy; Tan, Hongyang
2011-01-01
Distortion-product otoacoustic emissions (DPOAEs) were used to describe suppression growth in normal-hearing humans. Data were collected at eight f2 frequencies ranging from 0.5 to 8 kHz for L2 levels ranging from 10 to 60 dB sensation level. For each f2 and L2 combination, suppression was measured for nine or eleven suppressor frequencies (f3) whose levels varied from −20 to 85 dB sound pressure level (SPL). Suppression grew nearly linearly when f3 ≈ f2, grew more rapidly for f3 < f2, and grew more slowly for f3 > f2. These results are consistent with physiological and mechanical data from lower animals, as well as previous DPOAE data from humans, although no previous DPOAE study has described suppression growth for as wide a range of frequencies and levels. These trends were evident for all f2 and L2 combinations; however, some exceptions were noted. Specifically, suppression growth rate was less steep as a function of f3 for f2 frequencies ≤1 kHz. Thus, despite the qualitative similarities across frequency, there were quantitative differences related to f2, suggesting that there may be subtle differences in suppression for frequencies above 1 kHz compared to frequencies below 1 kHz. PMID:21361439
NASA Technical Reports Server (NTRS)
Betts, Juan F.
2001-01-01
The objective of the current study was to assess the repeatability of experiments at NASA Langley's Thermal Acoustic Fatigue Apparatus (TAFA) facility and to use these experiments to validate numerical models. Experiments show that power spectral density (PSD) curves were repeatable except at the resonant frequencies, which tended to vary between 5 Hz to 15 Hz. Results show that the thinner specimen had more variability in the resonant frequency location than the thicker sample, especially for modes higher than the first mode in the frequency range. Root Mean Square (RMS) tended to be more repeatable. The RMS behaved linearly through the SPL range of 135 to 153 dB. Standard Deviations (STDs) of the results tended to be relatively low constant up to about 147 dB. The RMS results were more repeatable than the PDS results. The STD results were less than 10% of the RMS results for both the 0.125 in (0.318 cm) and 0.062 in (0.1588 cm) thick plate. The STD of the PSD results were around 20% to 100% of the mean PSD results for non-resonant and resonant frequencies, respectively, for the 0.125 in (0.318 cm) thicker plate and between 25% to 125% of the mean PSD results, for nonresonant and resonant frequencies, respectively, for the thinner plate.
A Compact and Low-Cost MEMS Loudspeaker for Digital Hearing Aids.
Sang-Soo Je; Rivas, F; Diaz, R E; Jiuk Kwon; Jeonghwan Kim; Bakkaloglu, B; Kiaei, S; Junseok Chae
2009-10-01
A microelectromechanical-systems (MEMS)-based electromagnetically actuated loudspeaker to reduce form factor, cost, and power consumption, and increase energy efficiency in hearing-aid applications is presented. The MEMS loudspeaker has multilayer copper coils, an NiFe soft magnet on a thin polyimide diaphragm, and an NdFeB permanent magnet on the perimeter. The coil impedance is measured at 1.5 Omega, and the resonant frequency of the diaphragm is located far from the audio frequency range. The device is driven by a power-scalable, 0.25-mum complementary metal-oxide semiconductor class-D SigmaDelta amplifier stage. The class-D amplifier is formed by a differential H-bridge driven by a single bit, pulse-density-modulated SigmaDelta bitstream at a 1.2-MHz clock rate. The fabricated MEMS loudspeaker generates more than 0.8-mum displacement, equivalent to 106-dB sound pressure level (SPL), with 0.13-mW power consumption. Driven by the SigmaDelta class-D amplifier, the MEMS loudspeaker achieves measured 65-dB total harmonic distortion (THD) with a measurement uncertainty of less than 10%. Energy-efficient and cost-effective advanced hearing aids would benefit from further miniaturization via MEMS technology. The results from this study appear very promising for developing a compact, mass-producible, low-power loudspeaker with sufficient sound generation for hearing-aid applications.
Zaĭtseva, Iu V; Voloshina, P V; Liu, X; Ovadis, M I; Berg, G; Chernin, L S; Khmel', I A
2010-05-01
Most bacteria exist in the natural environment as biofilms, multicellular communities attached to hard surfaces. Biofilms have a characteristic architecture and are enclosed in the exopolymer matrix. Bacterial cells in biofilms are extremely resistant to antibacterial factors. It was shown in this work that the GrrA/GrrS system of global regulators of gene expression and the sigma S subunit of RNA polymerase (RpoS) play a significant role in positive regulation of biofilm formation in the rhizospheric bacterium Serratia plymuthica IC1270. Inactivation of grrS and rpoS genes resulted in an up to six-to-sevenfold and four-to-fivefold reduction in biofilm formation, respectively. Mutations in the grrS gene decreased the capacity of the bacterium for swarming motility. The splIR Quorum Sensing (QS) system was shown to negatively influence the biofilm formation. Transfer of the recombinant plasmid containing cloned genes splI/splR of S. plymuthica HRO-C48 into S. plymuthica IC1270 cells led to a twofold decrease of their ability to form biofilms. Inactivation of the splI gene coding for the synthase of N-acyl-homoserine lactones in S. plymuthica HRO-C48 resulted in a 2-2.5-fold increase in the level of biofilm formation, whereas the inclusion of plasmid carrying the cloned splI/splR genes into these mutant cells restored the biofilm formation to the normal level. The results obtained demonstrate that the formation of biofilms in S. plymuthica is positively regulated by the GrrA/GrrS and RpoS global regulators and is negatively regulated by the SplIR QS system.
Molina-Jijón, Eduardo; Rodríguez-Muñoz, Rafael; González-Ramírez, Ricardo; Namorado-Tónix, Carmen; Pedraza-Chaverri, José; Reyes, Jose L
2017-01-01
Hyperglycemia in diabetes alters tight junction (TJ) proteins in the kidney. We evaluated the participation of aldosterone (ALD), and the effect of spironolactone (SPL), a mineralocorticoid receptor antagonist, on the expressions of claudin-2, -4, -5 and -8, and occludin in glomeruli, proximal and distal tubules isolated from diabetic rats. Type 1 diabetes was induced in female Wistar rats by a single tail vein injection of streptozotocin (STZ), and SPL was administrated daily by gavage, from days 3-21. Twenty-one days after STZ injection the rats were sacrificed. In diabetic rats, the serum ALD levels were increased, and SPL-treatment did not have effect on these levels or in hyperglycemia, however, proteinuria decreased in SPL-treated diabetic rats. Glomerular damage, evaluated by nephrin and Wilm's tumor 1 (WT1) protein expressions, and proximal tubular damage, evaluated by kidney injury molecule 1 (Kim-1) and heat shock protein 72 kDa (Hsp72) expressions, were ameliorated by SPL. Also, SPL prevented decrement in claudin-5 in glomeruli, and claudin-2 and occludin in proximal tubules by decreasing oxidative stress, evaluated by superoxide anion (O2●-) production, and oxidative stress markers. In distal tubules, SPL ameliorated increase in mRNA, protein expression, and phosphorylation in threonine residues of claudin-4 and -8, through a serum and glucocorticoid-induced kinase 1 (SGK1), and with-no-lysine kinase 4 (WNK4) signaling pathway. In conclusion, this is the first study that demonstrates that ALD modulates the expression of renal TJ proteins in diabetes, and that the blockade of its actions with SPL, may be a promising therapeutic strategy to prevent alterations of TJ proteins in diabetic nephropathy.
Transcriptional regulation of cranial sensory placode development
Moody, Sally A.; LaMantia, Anthony-Samuel
2015-01-01
Cranial sensory placodes derive from discrete patches of the head ectoderm, and give rise to numerous sensory structures. During gastrulation, a specialized “neural border zone” forms around the neural plate in response to interactions between the neural and non-neural ectoderm and signals from adjacent mesodermal and/or endodermal tissues. This zone subsequently gives rise to two distinct precursor populations of the peripheral nervous system: the neural crest and the pre-placodal ectoderm (PPE). The PPE is a common field from which all cranial sensory placodes arise (adenohypophyseal, olfactory, lens, trigeminal, epibranchial, otic). Members of the Six family of transcription factors are major regulators of PPE specification, in partnership with co-factor proteins such as Eya. Six gene activity also maintains tissue boundaries between the PPE, neural crest and epidermis by repressing genes that specify the fates of those adjacent ectodermally-derived domains. As the embryo acquires anterior-posterior identity, the PPE becomes transcriptionally regionalized, and it subsequently subdivides into specific placodes with distinct developmental fates in response to signaling from adjacent tissues. Each placode is characterized by a unique transcriptional program that leads to the differentiation of highly specialized cells, such as neurosecretory cells, somatic sensory receptor cells, chemosensory neurons, peripheral glia and supporting cells. In this review, we summarize the transcriptional and signaling factors that regulate key steps of placode development, influence subsequent sensory neuron specification, and discuss what is known about mutations in some of the essential PPE genes that underlie human congenital syndromes. PMID:25662264
Pooling knowledge and improving safety for contracted works at a large industrial park.
Agnello, Patrizia; Ansaldi, Silvia; Bragatto, Paolo
2015-01-01
At a large chemical park maintenance is contracted by the major companies operating the plants to many small firms. The cultural and psychological isolation of contractor workers was recognized a root cause of severe accidents in the recent years. That problem is common in chemical industry. The knowledge sharing has been assumed a good key to involve contractors and sub contractors in safety culture and contributing to injuries prevention. The selection of personal protective equipment PPE for the maintenance works has been taken as benchmark to demonstrate the adequateness of the proposed approach. To support plant operators, contractors and subcontractors in PPE discussion, a method has been developed. Its core is a knowledge-base, organized in an Ontology, as suitable for inferring decisions. By means of this tool all stakeholders have merged experience and information and find out the right PPE, to be provided, with adequate training and information package. PPE selection requires sound competencies about process and environmental hazards, including major accident, preventive and protective measures, maintenance activities. These pieces of knowledge previously fragmented among plant operators and contractors, have to be pooled, and used to find out the adequate PPE for a number of maintenance works. The PPE selection is per se important, but it is also a good chance to break the contractors' isolation and involve them in safety objectives. Thus by pooling experience and practical knowledge, the common understanding of safety issues has been strengthened.
NASA Astrophysics Data System (ADS)
Bordelon, David E.; Cornejo, Christine; Grüttner, Cordula; Westphal, Fritz; DeWeese, Theodore L.; Ivkov, Robert
2011-06-01
Magnetic nanoparticles can create heat that can be exploited to treat cancer when they are exposed to alternating magnetic fields (AMF). At a fixed frequency, the particle heating efficiency or specific power loss (SPL) depends upon the magnitude of the AMF. We characterized the amplitude-dependent SPL of three commercial dextran-iron oxide nanoparticle suspensions through saturation to 94 kA/m with a calorimeter comprising a solenoid coil that generates a uniform field to 100 kA/m at ˜150 kHz. We also describe a novel method to empirically determine the appropriate range of the heating curve from which the SPL is then calculated. These results agree with SPL values calculated from the phenomenological Box-Lucas equation. We note that the amplitude-dependent SPL among the samples was markedly different, indicating significant magneto-structural variation not anticipated by current models.
Montiel-Ishino, Francisco A; Smyth, Joshua M; Murphy, Dennis J; Miranda, Patricia Y; Davis, Lisa A
2016-01-01
Background Farmworkers’ exposures to pesticides are reduced when they wear personal protective equipment (PPE), and mobile health (mHealth) platforms can potentially deliver information to farmworkers to help promote PPE use. However, little is known about the feasibility of using mHealth platforms to promote farmworkers’ use of PPE. Objective The objective of the study was to describe the development and feasibility-testing of Protect Yourself! (¡Protéjase!), an intervention designed to increase PPE use. As the vast majority of farmworkers in the United States are from Mexico, we examined the intervention in a primarily Mexican-origin farmworker population. Methods ¡Protéjase was developed in several steps. First, we performed ethnographic observations to understand what prevents PPE use. Next, we developed program components that met the challenges uncovered in the ethnographic observations, seeking direct feedback from farmworkers on each component. Feasibility was assessed using surveys and focus groups. Material was provided in Spanish or English at the preference of the participant. Finally, we pilot tested each component of the intervention, including: (1) PPE that was provided to each worker for their personal use during the intervention trial, and (2) delivery of an application-based tool that promoted the use of PPE through daily individualized messaging. Results 55 farmworkers enrolled in the study, but only 41 of 55 (75%) completed the entire pilot intervention trial. Results focus on the evaluation of the intervention, and include only those who completed the entire trial. Among farmworkers who completed the entire intervention trial, all but two farmworkers were born in Mexico and were Spanish speaking. Still, all study participants self-identified as Mexican or Mexican-American. When asked what changes were needed in the intervention’s messaging or delivery to increase user satisfaction, 22 out of 41 participants (54%) felt that no changes were needed. However, 16 of 41 participants (39%) suggested small changes to messaging (eg, refer to long pants as pants only) to improve their understanding of the messages. Finally, a small number (3 of 41 participants, 7%) felt that messages were difficult to read, primarily due to low literacy. Conclusions The ¡Protéjase! mHealth program demonstrated very good feasibility, satisfaction, and acceptance; potential improvements (eg, small modifications in messaging to increase farmworkers’ use) were noted. Overall, the PPE provided to workers as well as the mHealth platform were both perceived as useful for promoting PPE use. PMID:27066727
Lee, Joo-Young; Bakri, Ilham; Kim, Jung-Hyun; Son, Su-Young; Tochihara, Yutaka
2013-01-01
This study investigated the effects of firefighter personal protective equipment (PPE) on the determination of maximal oxygen uptake (VO(2max)) while using two different treadmill protocols: a progressive incline protocol (PIP) and a progressive speed protocol (PSP), with three clothing conditions (Light-light clothing; Boots-PPE with rubber boots; Shoes-PPE with running shoes). Bruce protocol with Light was performed for a reference test. Results showed there was no difference in VO(2max) between Bruce Light, PIP Light, and PSP Light. However, VO(2max) was reduced in Boots and Shoes with shortened maximal performance time (7 and 6 min reduced for PIP Boots and Shoes, respectively; 11 and 9 min reduced for PSP Boots and Shoes, respectively), whereas the increasing rate of VO(2) in Boots and Shoes during submaximal exercise was greater compared with Light. Wearing firefighter boots compared with wearing running shoes also significantly affected submaximal VO(2) but not VO(2max). These results suggest that firefighters' maximal performance determined from a typical VO(2max) test without wearing PPE may overestimate the actual performance capability of firefighters wearing PPE.
Lee, Joo-Young; Bakri, Ilham; Kim, Jung-Hyun; Son, Su-Young; Tochihara, Yutaka
2015-01-01
This study investigated the effects of firefighter personal protective equipment (PPE) on the determination of maximal oxygen uptake (VO2max) while using two different treadmill protocols: a progressive incline protocol (PIP) and a progressive speed protocol (PSP), with three clothing conditions (Light-light clothing; Boots-PPE with rubber boots; Shoes-PPE with running shoes). Bruce protocol with Light was performed for a reference test. Results showed there was no difference in VO2max between Bruce Light, PIP Light, and PSP Light. However, VO2max was reduced in Boots and Shoes with shortened maximal performance time (7 and 6 min reduced for PIP Boots and Shoes, respectively; 11 and 9 min reduced for PSP Boots and Shoes, respectively), whereas the increasing rate of VO2 in Boots and Shoes during submaximal exercise was greater compared with Light. Wearing firefighter boots compared with wearing running shoes also significantly affected submaximal VO2 but not VO2max. These results suggest that firefighters’ maximal performance determined from a typical VO2max test without wearing PPE may overestimate the actual performance capability of firefighters wearing PPE. PMID:23668854
Genome-wide analysis of the SPL/miR156 module and its interaction with the AP2/miR172 unit in barley
USDA-ARS?s Scientific Manuscript database
The SQUAMOSA-promoter binding like (SPL) gene family encodes transcription factors shown in a number of species to influence plant growth and development, but information about these genes in barley is limited. This study identified 13 barley SPL genes, within five distinct groups, that are ortholog...
USDA-ARS?s Scientific Manuscript database
Anthers and ovules are the sex organs that produce male and female spores, respectively. The SPOROCYTELESS (SPL)/NOZZLE (NZZ) encodes a nuclear protein controlling the sporogenesis in sex organs. However, the function of SPL in unisexual plants has never been explored, and the upstream regulators of...
Otani, Koji; Iwabuchi, Masumi; Sato, Katsuhiko; Konno, Shinichi; Kikuchi, Shinichi
2018-05-18
Laminoplasty is widely accepted as a standard treatment of cervical compressive myelopathy. However, due to the risk of postoperative complications such as neck symptoms, segmental partial laminectomy (SPL) is performed instead, which results in fewer postoperative symptoms. The aim of this study was to describe the difference in the incidence and severity of postoperative neck symptoms between traditional C3-C7 expansive open-door laminoplasty (ELAP) and SPL. A retrospective and comparative study was performed regarding neck complications following the two surgical procedures. Twenty patients underwent SPL, and an additional 20 age- and gender-matched patients underwent traditional C3-C7 ELAP. Preoperative and postoperative JOA scores were measured, and postoperative neck symptoms in both groups were evaluated using a self-administered questionnaire, according to the Neck Pain and Disability Scale. The total incidence of postoperative neck symptoms in the SPL group was similar to that in the ELAP group; however, the severity of symptoms was remarkably lower in the SPL group than in the ELAP group. SPL seems to be a better procedure for reducing postoperative neck symptoms, when compared with C3-C7 ELAP.
Dromey, C; Ramig, L O
1998-10-01
The purpose of the study was to compare the effects of changing sound pressure level (SPL) and rate on respiratory, phonatory, and articulatory behavior during sentence production. Ten subjects, 5 men and 5 women, repeated the sentence, "I sell a sapapple again," under 5 SPL and 5 rate conditions. From a multi-channel recording, measures were made of lung volume (LV), SPL, fundamental frequency (F0), semitone standard deviation (STSD), and upper and lower lip displacements and peak velocities. Loud speech led to increases in LV initiation, LV termination, F0, STSD, and articulatory displacements and peak velocities for both lips. Token-to-token variability in these articulatory measures generally decreased as SPL increased, whereas rate increases were associated with increased lip movement variability. LV excursion decreased as rate increased. F0 for the men and STSD for both genders increased with rate. Lower lip displacements became smaller for faster speech. The interspeaker differences in velocity change as a function of rate contrasted with the more consistent velocity performance across speakers for changes in SPL. Because SPL and rate change are targeted in therapy for dysarthria, the present data suggest directions for future research with disordered speakers.
Zhang, Huiyong; Zhao, Xin; Li, Jigang; Cai, Huaqing; Deng, Xing Wang; Li, Lei
2014-01-01
Light and copper are important environmental determinants of plant growth and development. Despite the wealth of knowledge on both light and copper signaling, the molecular mechanisms that integrate the two pathways remain poorly understood. Here, we use Arabidopsis thaliana to demonstrate an interaction between SQUAMOSA PROMOTER BINDING PROTEIN-LIKE7 (SPL7) and ELONGATED HYPOCOTYL5 (HY5), which mediate copper and light signaling, respectively. Through whole-genome chromatin immunoprecipitation and RNA sequencing analyses, we elucidated the SPL7 regulon and compared it with that of HY5. We found that the two transcription factors coregulate many genes, including those involved in anthocyanin accumulation and photosynthesis. Moreover, SPL7 and HY5 act coordinately to transcriptionally regulate MIR408, which results in differential expression of microRNA408 (miR408) and its target genes in response to changing light and copper conditions. We demonstrate that this regulation is tied to copper allocation to the chloroplast and plastocyanin levels. Finally, we found that constitutively activated miR408 rescues the distinct developmental defects of the hy5, spl7, and hy5 spl7 mutants. These findings revealed the existence of crosstalk between light and copper, mediated by a HY5-SPL7 network. Furthermore, integration of transcriptional and posttranscriptional regulation is critical for governing proper metabolism and development in response to combined copper and light signaling. PMID:25516599
NASA Astrophysics Data System (ADS)
Wollenweber, S. D.; Tsui, B. M. W.; Lalush, D. S.; Frey, E. C.; Gullberg, G. T.
1998-08-01
The objective of this study was to implement the Hotelling trace (HT) to evaluate the potential increase in defect detection in myocardial SPECT using high-resolution fan-beam (HRF) versus parallel-hole (HRP) collimation and compare results to a previously reported human observer study (G.K. Gregoriou et al., ibid., vol. 42, p. 1267-75, 1995). Projection data from the 3D MCAT torso phantom were simulated including the effects of attenuation, collimator-detector response blurring and scatter. Poisson noise fluctuations were then simulated. The HRP and HRF collimators had the same spatial resolution at 20 cm. The total counts in the projection data sets were proportional to the detection efficiencies of the collimators and on the order of that found in clinical Tc-99m studies. In six left-ventricular defect locations, the HT found for HRF was superior to that for HRP collimation. For HRF collimation, the HT was calculated for reconstructed images using 64/spl times/64, 128/spl times/128 and 192/spl times/192 grid sizes. The results demonstrate substantial improvement in myocardial defect detection when the grid size was increased from 64/spl times/64 to 128/spl times/128 and slight improvement from 128/spl times/128 to 192/spl times/192. Also, the performance of the Hotelling observer in terms of the HT at the different grid sizes correlates at better than 0.95 to that found in human observers in a previously reported observer experiment and ROC study.
NASA Astrophysics Data System (ADS)
Nojima, Kazuhisa; Ge, Sheng; Katayama, Yoshinori; Ueno, Shoogo; Iramina, Keiji
2010-05-01
The aim of this study is to investigate the effect of the stimulus frequency and pulses number of repetitive transcranial magnetic stimulation (rTMS) on the inter-reversal time (IRT) of perceptual reversal on the right superior parietal lobule (SPL). The spinning wheel illusion was used as the ambiguous figures stimulation in this study. To investigate the rTMS effect over the right SPL during perceptual reversal, 0.25 Hz 60 pulse, 1 Hz 60 pulse, 0.5 Hz 120 pulse, 1 Hz 120 pulse, and 1 Hz 240 pulse biphasic rTMS at 90% of resting motor threshold was applied over the right SPL and the right posterior temporal lobe (PTL), respectively. As a control, a no TMS was also conducted. It was found that rTMS on 0.25 Hz 60 pulse and 1 Hz 60 pulse applied over the right SPL caused shorter IRT. In contrast, it was found that rTMS on 1 Hz 240-pulse applied over the right SPL caused longer IRT. On the other hand, there is no significant difference between IRTs when the rTMS on 0.5 Hz 120 pulse and 1 Hz 120 pulse were applied over the right SPL. Therefore, the applying of rTMS over the right SPL suggests that the IRT of perceptual reversal is effected by the rTMS conditions such as the stimulus frequency and the number of pulses.
Legionella pneumophila S1P-lyase targets host sphingolipid metabolism and restrains autophagy
Rolando, Monica; Escoll, Pedro; Nora, Tamara; Botti, Joëlle; Boitez, Valérie; Daniels, Craig; Abraham, Gilu; Stogios, Peter J.; Skarina, Tatiana; Christophe, Charlotte; Dervins-Ravault, Delphine; Cazalet, Christel; Hilbi, Hubert; Rupasinghe, Thusitha W. T.; Tull, Dedreia; McConville, Malcolm J.; Ong, Sze Ying; Hartland, Elizabeth L.; Codogno, Patrice; Levade, Thierry; Naderer, Thomas; Savchenko, Alexei; Buchrieser, Carmen
2016-01-01
Autophagy is an essential component of innate immunity, enabling the detection and elimination of intracellular pathogens. Legionella pneumophila, an intracellular pathogen that can cause a severe pneumonia in humans, is able to modulate autophagy through the action of effector proteins that are translocated into the host cell by the pathogen’s Dot/Icm type IV secretion system. Many of these effectors share structural and sequence similarity with eukaryotic proteins. Indeed, phylogenetic analyses have indicated their acquisition by horizontal gene transfer from a eukaryotic host. Here we report that L. pneumophila translocates the effector protein sphingosine-1 phosphate lyase (LpSpl) to target the host sphingosine biosynthesis and to curtail autophagy. Our structural characterization of LpSpl and its comparison with human SPL reveals high structural conservation, thus supporting prior phylogenetic analysis. We show that LpSpl possesses S1P lyase activity that was abrogated by mutation of the catalytic site residues. L. pneumophila triggers the reduction of several sphingolipids critical for macrophage function in an LpSpl-dependent and -independent manner. LpSpl activity alone was sufficient to prevent an increase in sphingosine levels in infected host cells and to inhibit autophagy during macrophage infection. LpSpl was required for efficient infection of A/J mice, highlighting an important virulence role for this effector. Thus, we have uncovered a previously unidentified mechanism used by intracellular pathogens to inhibit autophagy, namely the disruption of host sphingolipid biosynthesis. PMID:26831115
Validation of the professional practice environment scale in nurse educators in hospitals.
Sayers, Jan Maree; Salamonson, Yenna; DiGiacomo, Michelle; Davidson, Patricia Mary
2016-03-01
To report an assessment of the psychometric properties of the Professional Practice Environment (PPE) scale in a sample of Australian nurse educators in acute care hospitals. Although nurse educators are important in an enabling work environment, there has been no reported exploration of their satisfaction with work in acute care hospitals. The factor structure and internal consistency of the PPE scale were consistent with Erickson's eight-factor model of the items, indicating the appropriateness of the scale as an assessment tool to measure the PPE of nurse educators. The PPE scale is useful for monitoring the work environment of nurse educators in clinical practice and the environmental effects influencing their recruitment, retention and job satisfaction. This work may inform the development of integrated professional practice environments where the professional practice and workplace satisfaction of nurse educators are optimised, influencing safe, quality patient care.
Nurses' use of hazardous drug-handling precautions and awareness of national safety guidelines.
Polovich, Martha; Martin, Susan
2011-11-01
To determine patterns of personal protective equipment (PPE) used by oncology nurses while handling hazardous drugs (HDs) and to assess knowledge of the 2004 National Institute for Occupational Safety and Health (NIOSH) Alert and its effect on precaution use. Descriptive, correlational. The Oncology Nursing Society 31st Annual Congress in Boston, MA, in 2006. 330 nurses who prepared and/or administered chemotherapy. Nurses described HD safe-handling precaution use by self-report survey. The availability and use of biologic safety cabinets and PPE. Respondents were well educated (57% had a bachelor's degree or more), experienced (X = 19, SD = 10.2 years in nursing and X = 12, SD = 7.9 years in oncology), and certified (70%; majority OCN®). Forty-seven percent of respondents were aware of the NIOSH Alert. Thirty-five percent of all participants and 93% of nurses in private practice settings reported preparing chemotherapy. Glove use (95%-100%) was higher than that reported in earlier studies, and gown use for drug preparation (65%), drug administration (50%), and handling excretions (23%) have remained unchanged. Double-gloving was rare (11%-18%). Nurses in private practices were less likely to have chemotherapy-designated PPE available, use PPE, and use spill kits for HD spills. Nurses have adopted glove use for HD handling; however, gown use remains comparatively low. Chemotherapy-designated PPE is not always provided by employers. Nurses lack awareness of current safety guidelines. Nurses must know about the risks of HD exposure and ways to reduce exposure. Employers must provide appropriate PPE and encourage its use. Alternative methods of disseminating safety recommendations are needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venderbosch, R.W.; Nelissen, J.G.L.; Peijs, A.A.J.M.
1993-12-31
The application of poly(2,6-dimethyl-1,4-phenylene ether), PPE, as a matrix material for continuous carbon fiber reinforced composites was studied. PPE is an amorphous thermoplastic exhibiting a high glass transition temperature (220 C) and outstanding mechanical properties with respect to e.g. toughness. However, due to the limited thermal stability at temperatures above T{sub g}, PPE can be regarded as an intractable polymer. Consequently, the introduction of PPE in a composite structure via a melt impregnation route is not feasible. In this investigation a solution impregnation route, using epoxy resin as a reactive solvent, was developed. During impregnation epoxy resin acts as amore » solvent which results in enhanced flow and a reduced processing temperature enabling the preparation of high quality composites, avoiding any degradation. Upon curing of the neat system, phase separation and phase inversion occurs resulting in a continuous PPE matrix filled with glassy epoxy spheres. As a result of this morphology the mechanical and thermal properties of the final material are mainly dominated by the PPE component. In composite applications, a strong influence of the polarity of the carbon fiber surface on the resulting matrix morphology was found. Upon curing, phase separation is initiated at the fiber surface resulting in an epoxy `interlayer` at the fiber surface. This phenomenon can provide a high level of interfacial adhesion. A preliminary investigation of the resulting composite materials revealed outstanding mechanical properties with respect to e.g. interlaminar toughness and strength.« less
A Comparison of Personal Protective Standards: Caring for Patients With Ebola Virus.
Franklin, Sativa Michelle
2016-01-01
The purpose of this article is to discuss the variance in requirements for personal protective equipment (PPE) used among healthcare workers to treat patients actively infected with the Ebola virus in West Africa. The Ebola virus is a highly contagious disease, which has killed 11020 people within the past year. In order to combat the disease and treat those with active infections, healthcare workers are required to use PPE. The guidelines for the PPE, in addition to the requirements of what should be worn, are varied between the World Health Organization (WHO) and the Centers for Disease Control and Prevention. A military unit was composed of sister services (Army, Navy, and Air Force) deployed to Monrovia, Liberia, to assist in mitigating the devastating effects of the Ebola virus. Each service member was taught PPE standards according to the WHO and were assigned to teach healthcare workers from around the world on how to manage the care of patients infected with the Ebola virus, while simultaneously taking diligent precautions to protect themselves against the deadly disease. More than 1500 healthcare workers were instructed on the latest PPE standards before they entered into the Ebola treatment units (ETUs) that were being constructed in Liberia. Cumulative death rates from the Ebola virus in Liberia increased from 2413 in October 2014 to 3686 by January 2015. The rapid decline in Ebola mortality is multifactorial. The efforts of US military medical personnel likely were a contributing factor in this rapid decline as those international health workers were afforded the latest in PPE training with strict attention to detail. US military medical personnel, in concert with other governmental agencies, created a potent force multiplier in the efforts to curb this deadly infection. The educational initiative was essential to the slowdown in the spread of the Ebola virus in Liberia. Recommendations for a detailed review of the PPE standards and variances in practice from both WHO and Centers for Disease Control and Prevention are necessary to standardize processes across international healthcare workers to expedite the care for future infectious disease outbreaks. A possible solution is to modify the PPE process to standardize with the WHO guidelines. Key stakeholders from all levels (staff nurse, clinical nurse specialist, nurse managers, infectious disease experts, etc) need to be heavily involved in this process.
The Danger Zone for Noise Hazards Around the Black Hawk Helicopter.
Jones, Heath G; Greene, Nathaniel T; Chen, Michael R; Azcona, Cierrah M; Archer, Brandon J; Reeves, Efrem R
2018-06-01
During ground operations, rotary-wing aircraft engines and subsystems produce noise hazards that place airfield personnel at risk for hearing damage. The noise exposure levels outside the aircraft during various operating conditions, and the distances from aircraft at which they drop to safe levels, are not readily available. The current study measured noise levels at various positions around the UH-60 Black Hawk helicopter for three operating conditions typically used when the aircraft is on the ground. Microphones were positioned systematically around the helicopter and A-weighted sound pressure levels (SPLs) were computed from the recordings. In addition, the 85-dBA SPL contour around the aircraft was mapped. The resulting A-weighted SPLs and contour mapping were used to determine the noise hazard area around the helicopter. Measurements reported here show noise levels of 105 dB or greater in all operating conditions. The fueling location at the left rear of the aircraft near the auxiliary power unit (APU) is the area of greatest risk for noise-induced hearing loss (NIHL). Additionally, sound field contours indicate noise hazard areas (>85 dBA SPL) can extend beyond 100 ft from the helicopter. This report details the areas of greatest risk for auditory injury around the UH-60 Black Hawk helicopter. Our findings suggest the area of hazardous noise levels around the aircraft can extend to neighboring aircraft, particularly on the side of the aircraft where the APU is located. Hearing protection should be worn whenever the aircraft is operating, even if working at a distance.Jones HG, Greene NT, Chen MR, Azcona CM, Archer BJ, Reeves ER. The danger zone for noise hazards around the Black Hawk helicopter. Aerosp Med Hum Perform. 2018; 89(6):547-551.
Regulation of OsSPL14 by OsmiR156 defines ideal plant architecture in rice.
Jiao, Yongqing; Wang, Yonghong; Xue, Dawei; Wang, Jing; Yan, Meixian; Liu, Guifu; Dong, Guojun; Zeng, Dali; Lu, Zefu; Zhu, Xudong; Qian, Qian; Li, Jiayang
2010-06-01
Increasing crop yield is a major challenge for modern agriculture. The development of new plant types, which is known as ideal plant architecture (IPA), has been proposed as a means to enhance rice yield potential over that of existing high-yield varieties. Here, we report the cloning and characterization of a semidominant quantitative trait locus, IPA1 (Ideal Plant Architecture 1), which profoundly changes rice plant architecture and substantially enhances rice grain yield. The IPA1 quantitative trait locus encodes OsSPL14 (SOUAMOSA PROMOTER BINDING PROTEIN-LIKE 14) and is regulated by microRNA (miRNA) OsmiR156 in vivo. We demonstrate that a point mutation in OsSPL14 perturbs OsmiR156-directed regulation of OsSPL14, generating an 'ideal' rice plant with a reduced tiller number, increased lodging resistance and enhanced grain yield. Our study suggests that OsSPL14 may help improve rice grain yield by facilitating the breeding of new elite rice varieties.
Effects of Bel Canto Training on Acoustic and Aerodynamic Characteristics of the Singing Voice.
McHenry, Monica A; Evans, Joseph; Powitzky, Eric
2016-03-01
This study was designed to assess the impact of 2 years of operatic training on acoustic and aerodynamic characteristics of the singing voice. This is a longitudinal study. Participants were 21 graduate students and 16 undergraduate students. They completed a variety of tasks, including laryngeal videostroboscopy, audio recording of pitch range, and singing of syllable trains at full voice in chest, passaggio, and head registers. Inspiration, intraoral pressure, airflow, and sound pressure level (SPL) were captured during the syllable productions. Both graduate and undergraduate students significantly increased semitone range and SPL. The contributions to increased SPL were typically increased inspiration, increased airflow, and reduced laryngeal resistance, although there were individual differences. Two graduate students increased SPL without increased airflow and likely used supraglottal strategies to do so. Students demonstrated improvements in both acoustic and aerodynamic components of singing. Increasing SPL primarily through respiratory drive is a healthy strategy and results from intensive training. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Zhang, Heng; Huang, Zhaohui; Xiao, Limin; Jiang, Xinye; Chen, Daozhen; Wei, Yarong
2017-09-01
The association between vitamin D deficiency and early spontaneous pregnancy loss (SPL) is unclear. To assess the association of serum 25-hydroxyvitamin D (25(OH)D) and SPL. Embase, PubMed, and Web of Science were searched for relevant papers published before February 20, 2016, using search terms including "vitamin D" and "pregnancy loss." Case-control and cohort studies investigating the relationship of maternal serum 25(OH)D and SPL were included. Two authors independently extracted original data from the selected papers. The DerSimonian-Laird random-effects model was used to perform the meta-analysis. Heterogeneity was assessed by calculating I 2 . Five studies, including 10 630 pregnant women, met the inclusion criteria. There was no significant association between a low 25(OH)D level and an increased risk of SPL. In a subgroup analysis, an extremely low 25(OH)D level (<20 ng/mL) was significantly associated with an increased risk of SPL in the first trimester (relative risk 2.24, 95% confidence interval 1.15-4.37); the heterogeneity across studies was not significant (I 2 =0.0%, P=0.355). Severe Vitamin D deficiency could be detrimental to early embryonic development and increase the risk of early SPL. © 2017 International Federation of Gynecology and Obstetrics.
Scheperjans, Filip; Palomero-Gallagher, Nicola; Grefkes, Christian; Schleicher, Axel; Zilles, Karl
2005-11-01
Regional distributions of ligand binding sites of 12 different neurotransmitter receptors (glutamatergic: AMPA, kainate, NMDA; GABAergic: GABA(A), GABA(B); cholinergic: muscarinic M2, nicotinic; adrenergic: alpha1, alpha2; serotonergic: 5-HT1A, 5-HT2; dopaminergic: D1) were studied in human postmortem brains by means of quantitative receptor autoradiography. Binding site densities were measured in the superior parietal lobule (SPL) (areas 5L, 5M, 5Ci, and different locations within Brodmann's area (BA) 7), somatosensory (BA 2), and visual cortical areas (BA 17, and different locations within BAs 18 and 19). Similarities of receptor distribution between cortical areas were analyzed by cluster analysis, uni- and multivariate statistics of mean receptor densities (averaged over all cortical layers), and profiles representing the laminar distribution patterns of receptors. A considerable heterogeneity of regional receptor densities and laminar patterns between the sites was found in the SPL and the visual cortex. The most prominent regional differences were found for M2 receptors. In the SPL, rostrocaudally oriented changes of receptor densities were more pronounced than those in mediolateral direction. The receptor distribution in the rostral SPL was more similar to that of the somatosensory cortex, whereas caudal SPL resembled the receptor patterns of the dorsolateral extrastriate visual areas. These results suggest a segregation of the different SPL areas based on receptor distribution features typical for somatosensory or visual areas, which fits to the dual functional role of this cortical region, i.e., the involvement of the human SPL in visuomotor and somatosensory motor transformations.
Voice Use Among Music Theory Teachers: A Voice Dosimetry and Self-Assessment Study.
Schiller, Isabel S; Morsomme, Dominique; Remacle, Angélique
2017-07-25
This study aimed (1) to investigate music theory teachers' professional and extra-professional vocal loading and background noise exposure, (2) to determine the correlation between vocal loading and background noise, and (3) to determine the correlation between vocal loading and self-evaluation data. Using voice dosimetry, 13 music theory teachers were monitored for one workweek. The parameters analyzed were voice sound pressure level (SPL), fundamental frequency (F0), phonation time, vocal loading index (VLI), and noise SPL. Spearman correlation was used to correlate vocal loading parameters (voice SPL, F0, and phonation time) and noise SPL. Each day, the subjects self-assessed their voice using visual analog scales. VLI and self-evaluation data were correlated using Spearman correlation. Vocal loading parameters and noise SPL were significantly higher in the professional than in the extra-professional environment. Voice SPL, phonation time, and female subjects' F0 correlated positively with noise SPL. VLI correlated with self-assessed voice quality, vocal fatigue, and amount of singing and speaking voice produced. Teaching music theory is a profession with high vocal demands. More background noise is associated with increased vocal loading and may indirectly increase the risk for voice disorders. Correlations between VLI and self-assessments suggest that these teachers are well aware of their vocal demands and feel their effect on voice quality and vocal fatigue. Visual analog scales seem to represent a useful tool for subjective vocal loading assessment and associated symptoms in these professional voice users. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Kawanaka, Hirofumi; Akahoshi, Tomohiko; Nagao, Yoshihiro; Kinjo, Nao; Yoshida, Daisuke; Matsumoto, Yoshihiro; Harimoto, Norifumi; Itoh, Shinji; Yoshizumi, Tomoharu; Maehara, Yoshihiko
2018-01-01
Laparoscopic gastric devascularization(Lap GDS) and splenectomy (SPL) for gastric varices is technically challenging because of highly developed collateral vessels and bleeding tendency. We investigated the feasibility of customization of Lap GDS and SPL based on CT vascular anatomy. We analyzed 61 cirrhotic patients with gastric varices who underwent Lap GDS and SPL between 2006 and 2014. Lap GDS was customized according to the afferent feeding veins (left gastric vein (LGV) and/or posterior gastric vein (PGV)/short gastric vein (SGV)) and efferent drainage veins (gastrorenal shunt and/or gastrophrenic shunt, or numerous retroperitoneal veins) based on CT imaging. Thirty-four patients with efferent drainage veins suitable for balloon-occluded retrograde transvenous obliteration (B-RTO) underwent B-RTO instead of surgical GDS, with subsequent Lap SPL. Among 27 patients with gastric varices unsuitable for B-RTO, 15 patients with PGV/SGV underwent Lap GDS of the greater curvature and SPL, and 12 patients with LGV or LGV/PGV/SGV underwent Lap GDS of the greater and lesser curvature and SPL. The mean operation time was 294 min and mean blood loss was 198 g. There was no mortality or severe morbidity. Gastric varices were eradicated in all 61 patients, with no bleeding or recurrence during a mean follow-up of 55.9 months. The cumulative 3-, 5-, and 7-year survival rates were 92, 82, and 64%, respectively. Lap GDS and SPL customized based on CT vascular anatomy is a safe and effective procedure for treating gastric varices.
Palatability and chemical safety of apple juice fortified with pomegranate peel extract.
Altunkaya, Arzu; Hedegaard, Rikke V; Harholt, Jesper; Brimer, Leon; Gökmen, Vural; Skibsted, Leif H
2013-10-01
Pomegranate peel extract (PPE), a by-product of the pomegranate juice industry with potential health effects, was explored for use to fortify reconstituted apple juice in the concentration range 0.5 to 2.0% (w/w). Radical scavenging and antioxidative capacities of the fortified apple juices were evaluated using (i) electron spin resonance (ESR) to quantify their ability to scavenge the stable radical Fremy's salt and (ii) the Trolox equivalent antioxidant capacity (TEAC) assay and compared to apple juice without fortification as control. The highest antioxidative capacity was found in the apple juice fortified with the highest percentage of pomegranate peel extract, while the optimal sensory quality was found by addition of 0.5 g PPE per 100 mL. The Artemia salina assay was used as a fast screening method for evaluating overall toxicity, and showed little toxicity with up to 1.0 g per 100 mL addition of PPE, but increasing toxicity at higher concentrations. Accordingly, it is important to balance addition of PPE, when used for enrichment of apple juice in order to obtain a healthier product, without compromising the sensorial quality or toxicological safety of the apple juice. Concentrations between 0.5 and 1.0 g PPE per 100 mL seem to be acceptable.
[SOMATOTYPE, NUTRITIONAL STATUS AND BLOOD GLUCOSE LEVEL OF PHYSICAL EDUCATION STUDENTS].
Valdés-Badilla, Pablo; Salvador Soler, Noemí; Godoy-Cumillaf, Andrés; Carmona-López, María Ines; Fernández, Juan José; Durán-Agüero, Samuel
2015-09-01
classical studies have compared the glycemia with the nutritional status in both children and adults; however studies that consider also somatotype are unknown. associating the somatotype and nutritional status with the glycemic level of students of Pedagogy in Physical Education (PPE). the sample included 40 subjects, divided between 13 women and 27 men. It was determined in each subject BMI, somatotype and also a fasting blood glucose sample was obtained. the somatotype in male PPE students was mesomorphic (3-2-2) with a nutritional status of overweight (25 kg/m2) and balanced mesomorphic (4-4-2) with normal weight (22 kg/m2) in women PPE students. While average fasting blood glucose was 69 mg / dl. No association between somatotype and BMI with blood sugar levels of students of PPE, however, women of PEF showed significant positive correlations between mesomorphy and the ICC (0.577) and between glycemia and height (0.650). somatotype and BMI of the students of PPE are consistent with their age and sex, but no association between somatotype and glucose was observed. Moreover, the average blood glucose levels were somewhat lower compared to normative tables, a situation that could be related to physical activity, however, requires further study to confirm it. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Chemical composition of Propolis Extract ACF® and activity against herpes simplex virus.
Bankova, V; Galabov, A S; Antonova, D; Vilhelmova, N; Di Perri, B
2014-09-25
Propolis Extract ACF(®) (PPE) is a purified extract manufactured from propolis collected in a Canadian region rich in poplar trees, and it is the active substance of a topical ointment used against herpes labialis (cold sores or fever blisters). Aim of this study was to analyze the chemical composition of PPE in order to understand the plant origin and possible relations between compounds and antiviral activity, and to characterize the antiviral activity of the extract against herpes simplex virus in vitro. The analysis of the propolis extract samples was conducted by Gas Chromatography-Mass Spectrometry (GC-MS). The antiviral activity was tested against herpes simplex viruses type 1 and type 2 in MDBK cell cultures by treating the cells with PPE at the time of virus adsorption, and by incubating the virus with the extract before infection (virucidal assay). Results from the GC-MS analyses revealed a dual plant origin of PPE, with components derived from resins of two different species of poplar. The chemical composition appeared standardized between extract samples and was also reproduced in the sample of topical ointment. The antiviral studies showed that PPE had a pronounced virucidal effect against herpes simplex viruses type 1 and type 2, and also interfered with virus adsorption. Copyright © 2014 Elsevier GmbH. All rights reserved.
Occupational safety beliefs among Latino residential roofing workers.
Arcury, Thomas A; Summers, Phillip; Carrillo, Lourdes; Grzywacz, Joseph G; Quandt, Sara A; Mills, Thomas H
2014-06-01
This analysis describes beliefs about work safety and personal protective equipment (PPE) among Latino roofing workers, it delineates their perceptions of work environment characteristics that affect work safety and PPE use, and it describes how they experience work injuries and the consequences of these injuries. In-depth interviews were completed with 10 current and former Latino residential roofers. Interview transcripts were subjected to systematic qualitative analysis. Participants' valued productivity over safety, and this had a negative influence on their safety behavior and reduced their PPE use. They understood that roofing was hazardous. They limited use of PPE when they felt it reduced productivity and when it was uncomfortable. Work environment characteristics that affected safety included company size, the physical demands of the job, lack of training, the need for work, general life stress, and distractions at work. An injury had to result in lost work time to be considered significant. Access to health care is limited by employers not providing Workers' compensation. Future research is needed to substantiate these descriptive results and to delineate factors that are associated with safety behavior and use of PPE. Interventions, based on a lay health educator model, are needed to improve safety in this population. Safety regulations need to be evaluated and their enforcement needs to be improved. © 2013 Wiley Periodicals, Inc.
PREPARTICIPATION SCREENING – THE SPORTS PHYSICAL THERAPY PERSPECTIVE
Blackburn, Turner A.; Boucher, Brenda
2013-01-01
Background and Purpose: The sports physical therapist (SPT) is uniquely qualified to participate in the provision of preparticipation physical examinations (PPE). The PPE is recommended prior to athletic participation and required by many jurisdictions. There is little research to support the process and components; however, a number of professional organizations have recommendations that direct the PPE process. Description of Topic and Related Evidence: This clinical commentary highlights the role of the sports physical therapist and current evidence related to the preparticipation physical examination process. Data sources were limited to include professional positions and peer reviewed publications from 1988 through January 2013. Relation to Clinical Practice: Preparticipation physicals should be useful, comprehensive, and cost effective for the athlete and the health care team. Additional research is indicated in many of the areas of the PPE. The SPT is a valuable member of the health care team and can be a primary facilitator of the PPE in concert with the physician, athletic trainer, athletic organization administrators, and others. Well‐designed and inclusive PPEs can be provided to meet the major objectives of identification of athletes at risk. Controversy continues over the extent of the cardiac screening component as well as other sport or athlete specific components. Level of Evidence: 5 PMID:23593556
Patel, Anita; D'Alessandro, Maryann M; Ireland, Karen J; Burel, W Greg; Wencil, Elaine B; Rasmussen, Sonja A
Personal protective equipment (PPE) that protects healthcare workers from infection is a critical component of infection control strategies in healthcare settings. During a public health emergency response, protecting healthcare workers from infectious disease is essential, given that they provide clinical care to those who fall ill, have a high risk of exposure, and need to be assured of occupational safety. Like most goods in the United States, the PPE market supply is based on demand. The US PPE supply chain has minimal ability to rapidly surge production, resulting in challenges to meeting large unexpected increases in demand that might occur during a public health emergency. Additionally, a significant proportion of the supply chain is produced off-shore and might not be available to the US market during an emergency because of export restrictions or nationalization of manufacturing facilities. Efforts to increase supplies during previous public health emergencies have been challenging. During the 2009 H1N1 influenza pandemic and the 2014 Ebola virus epidemic, the commercial supply chain of pharmaceutical and healthcare products quickly became critical response components. This article reviews lessons learned from these responses from a PPE supply chain and systems perspective and examines ways to improve PPE readiness for future responses.
Does the Ovarian Stimulation Phase Length Predict In vitro Fertilization Outcomes?
Alport, Brie; Case, Allison; Lim, Hyun; Baerwald, Angela
2011-01-01
Background Bi-directional communication between the follicle and oocyte is necessary to regulate follicle and oocyte development. Currently, it is not practical to monitor the serial growth of individual follicles during assisted reproduction. The ovarian stimulation phase length (SPL) is an indirect measure of mean follicular growth rate. The objective of this study was to test the hypothesis that a short or long SPL would be associated with suboptimal outcomes in women undergoing in vitro fertilization (IVF). Materials and Methods A retrospective cohort study was conducted in 140 women who underwent IVF. Follicle development was monitored every 2-3 days during ovarian stimulation using transvaginal ultrasonography. Once > 3 follicles reached ≥ 17 mm, human chorionic gonadotropin (hCG) was administered. Oocyte retrieval was performed approximately 35 hours after hCG. Oocytes underwent IVF on the day of collection and were evaluated daily thereafter. Embryos were transferred on days 3 or 5, depending on the number and quality of embryos available. Associations between SPL, age, follicle, oocyte, embryo and pregnancy outcomes were evaluated (SPSS version 17.0; SPSS Inc., Chicago, IL, USA). Results A SPL of 11 days was associated with an optimal number of follicles that developed to ≥ 6 mm, ≥ 10 mm and ≥ 15 mm; serum estradiol concentrations; and number of oocytes collected (p<0.05). Gradual reductions in the number of developing follicles, serum estradiol concentrations and number of oocytes collected occurred with SPL less than or greater than 11 days (p<0.05). The SPL did not influence endometrial, embryo or pregnancy outcomes (p>0.05). Associations between SPL and outcomes were not influenced by age (p>0.05). Conclusion The ovarian SPL can be used to predict the number of follicles that develop, oocytes collected and serum estradiol concentrations, but not embryo or pregnancy outcomes. PMID:25101156
Reusable single-port access device shortens operative time and reduces operative costs.
Shussman, Noam; Kedar, Asaf; Elazary, Ram; Abu Gazala, Mahmoud; Rivkind, Avraham I; Mintz, Yoav
2014-06-01
In recent years, single-port laparoscopy (SPL) has become an attractive approach for performing surgical procedures. The pitfalls of this approach are technical and financial. Financial concerns are due to the increased cost of dedicated devices and prolonged operating room time. Our aim was to calculate the cost of SPL using a reusable port and instruments in order to evaluate the cost difference between this approach to SPL using the available disposable ports and standard laparoscopy. We performed 22 laparoscopic procedures via the SPL approach using a reusable single-port access system and reusable laparoscopic instruments. These included 17 cholecystectomies and five other procedures. Operative time, postoperative length of stay (LOS) and complications were prospectively recorded and were compared with similar data from our SPL database. Student's t test was used for statistical analysis. SPL was successfully performed in all cases. Mean operative time for cholecystectomy was 72 min (range 40-116). Postoperative LOS was not changed from our standard protocols and was 1.1 days for cholecystectomy. The postoperative course was within normal limits for all patients and perioperative morbidity was recorded. Both operative time and length of hospital stay were shorter for the 17 patients who underwent cholecystectomy using a reusable port than for the matched previous 17 SPL cholecystectomies we performed (p < 0.001). Prices of disposable SPL instruments and multiport access devices as well as extraction bags from different manufacturers were used to calculate the cost difference. Operating with a reusable port ended up with an average cost savings of US$388 compared with using disposable ports, and US$240 compared with standard laparoscopy. Single-port laparoscopic surgery is a technically challenging and expensive surgical approach. Financial concerns among others have been advocated against this approach; however, we demonstrate herein that using a reusable port and instruments reduces operative time and overall operative costs, even beyond the cost of standard laparoscopy.
Genome-wide identification and characterization of the SBP-box gene family in Petunia.
Zhou, Qin; Zhang, Sisi; Chen, Feng; Liu, Baojun; Wu, Lan; Li, Fei; Zhang, Jiaqi; Bao, Manzhu; Liu, Guofeng
2018-03-12
SQUAMOSA PROMOTER BINDING PROTEIN (SBP)-box genes encode a family of plant-specific transcription factors (TFs) that play important roles in many growth and development processes including phase transition, leaf initiation, shoot and inflorescence branching, fruit development and ripening etc. The SBP-box gene family has been identified and characterized in many species, but has not been well studied in Petunia, an important ornamental genus. We identified 21 putative SPL genes of Petunia axillaris and P. inflata from the reference genome of P. axillaris N and P. inflata S6, respectively, which were supported by the transcriptome data. For further confirmation, all the 21 genes were also cloned from P. hybrida line W115 (Mitchel diploid). Phylogenetic analysis based on the highly conserved SBP domains arranged PhSPLs in eight groups, analogous to those from Arabidopsis and tomato. Furthermore, the Petunia SPL genes had similar exon-intron structure and the deduced proteins contained very similar conserved motifs within the same subgroup. Out of 21 PhSPL genes, fourteen were predicted to be potential targets of PhmiR156/157, and the putative miR156/157 response elements (MREs) were located in the coding region of group IV, V, VII and VIII genes, but in the 3'-UTR regions of group VI genes. SPL genes were also identified from another two wild Petunia species, P. integrifolia and P. exserta, based on their transcriptome databases to investigate the origin of PhSPLs. Phylogenetic analysis and multiple alignments of the coding sequences of PhSPLs and their orthologs from wild species indicated that PhSPLs were originated mainly from P. axillaris. qRT-PCR analysis demonstrated differential spatiotemperal expression patterns of PhSPL genes in petunia and many were expressed predominantly in the axillary buds and/or inflorescences. In addition, overexpression of PhSPL9a and PhSPL9b in Arabidopsis suggested that these genes play a conserved role in promoting the vegetative-to-reproductive phase transition. Petunia genome contains at least 21 SPL genes, and most of the genes are expressed in different tissues. The PhSPL genes may play conserved and diverse roles in plant growth and development, including flowering regulation, leaf initiation, axillary bud and inflorescence development. This work provides a comprehensive understanding of the SBP-box gene family in Petunia and lays a significant foundation for future studies on the function and evolution of SPL genes in petunia.
Sphingosine 1-phosphate lyase enzyme assay using a BODIPY-labeled substrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bandhuvula, Padmavathi; Li Zaiguo; Bittman, Robert
2009-03-06
Sphingosine 1-phosphate lyase (SPL) is responsible for the irreversible catabolism of sphingosine 1-phosphate, which signals through five membrane receptors to mediate cell stress responses, angiogenesis, and lymphocyte trafficking. The standard assay for SPL activity utilizes a radioactive dihydrosphingosine 1-phosphate substrate and is expensive and cumbersome. In this study, we describe an SPL assay that employs an {omega}-labeled BODIPY-sphingosine 1-phosphate substrate, allowing fluorescent product detection by HPLC and incorporating advantages of the BODIPY fluorophore. The major aldehyde product is confirmed by reaction with 2,4-dinitrophenylhydrazine. The SPL-catalyzed reaction is linear over a 30 min time period and yields a K{sub m} ofmore » 35 {mu}M for BODIPY-sphingosine 1-phosphate.« less
Nair, Shiny; Pandey, Akhilesh Datt; Mukhopadhyay, Sangita
2011-05-01
Mycobacterium tuberculosis bacteria are known to suppress proinflammatory cytokines like IL-12 and TNF-α for a biased Th2 response that favors a successful infection and its subsequent intracellular survival. However, the signaling pathways targeted by the bacilli to inhibit production of these cytokines are not fully understood. In this study, we demonstrate that the PPE18 protein of M. tuberculosis inhibits LPS-induced IL-12 and TNF-α production by blocking nuclear translocation of p50, p65 NF-κB, and c-rel transcription factors. We found that PPE18 upregulates the expression as well as tyrosine phosphorylation of suppressor of cytokine signaling 3 (SOCS3), and the phosphorylated SOCS3 physically interacts with IκBα-NF-κB/rel complex, inhibiting phosphorylation of IκBα at the serine 32/36 residues by IκB kinase-β, and thereby prevents nuclear translocation of the NF-κB/rel subunits in LPS-activated macrophages. Specific knockdown of SOCS3 by small interfering RNA enhanced IκBα phosphorylation, leading to increased nuclear levels of NF-κB/rel transcription factors vis-a-vis IL-12 p40 and TNF-α production in macrophages cotreated with PPE18 and LPS. The PPE18 protein did not affect the IκB kinase-β activity. Our study describes a novel mechanism by which phosphorylated SOCS3 inhibits NF-κB activation by masking the phosphorylation site of IκBα. Also, this study highlights the possible mechanisms by which the M. tuberculosis suppresses production of proinflammatory cytokines using PPE18.
Levesque, D L; Arif, A A; Shen, J
2012-04-01
There are inconsistencies about the effects of farmworker housing and workplace conditions and use of self-protective behavior practices and personal protective equipment (PPE). To investigate the association between workplace and housing conditions and farmworker use of pesticide safety practices and PPE. This study was conducted in 4 counties in North Carolina, USA, from July to October, 2010, during the agricultural growing season. Farmworkers working in agriculture aged 18 to 62 (n = 187) were administered a structured questionnaire to collect self-reported measures on housing and workplace conditions. Use of pesticide safety and PPE were examined by asking questions about wearing gloves, wearing socks, and wearing a hat. Chi-square and multiple logistic regression analyses were used for statistical analyses. Farmworkers reporting availability of enough hot and cold water for bathing and doing laundry were 13.6 times more likely to use pesticide safety practices (adjusted OR: 13.6, 95% CI: 1.4-135.4), whereas, those who reported that soap for handwashing was always or usually available while doing agricultural work were 7.8 times more likely to use pesticide safety practices (adjusted OR: 7.8, 95% CI: 3.3-18.5). Farmworkers that reported access to water to wash their hands with while performing agricultural work were more likely to use PPE (adjusted OR: 3.4, 95% CI: 1.3-9.2). Some migrant farmworker labor camps are not supplying acceptable housing conditions such as 1 handwashing sink per 6 people (n = 10, 5.4%). Use of pesticide safety practices and PPE is greater when farmers provide decontamination supplies. Improvement of housing and workplace conditions are crucial to increase use of pesticide safety practices and PPE.
Lane, E L; Cheetham, S; Jenner, P
2008-01-01
The monoamine uptake inhibitor BTS 74 398 induces ipsilateral circling in 6-hydroxydopamine (6-OHDA) lesioned rats without induction of abnormal motor behaviours associated with L-dopa administration. We examined whether this was reflected in the expression of peptide mRNA in the direct and indirect striatal output pathways.6-OHDA lesioning of the nigrostriatal pathway increased striatal expression of PPE-A mRNA and decreased levels of PPT mRNA with PPE-B mRNA expression remaining unchanged. Acute L-dopa administration normalised PPE-A mRNA and elevated PPT mRNA while PPE-B mRNA expression remained unchanged. Acute administration of BTS 74 398 did not alter striatal peptide mRNA levels. Following chronic treatment with L-dopa, PPE-A mRNA expression in the lesioned striatum continued to be normalised and PPT mRNA was increased compared to the intact side. PPE-B mRNA expression was also markedly increased relative to the non-lesioned striatum. Chronic BTS 74 398 administration did not alter mRNA expression in the 6-OHDA lesioned striatum although small increases in PPT mRNA expression in the intact and sham lesioned striatum were observed. The failure of BTS 74 398 to induce changes in striatal neuropeptide mRNA correlated with its failure to induce abnormal motor behaviours or behavioural sensitisation but does not explain how it produces a reversal of motor deficits. An action in another area of the brain appears likely and may explain the subsequent failure of BTS 74 398 and related compounds to exert anti-parkinsonian actions in man.
Afonso, João Paulo Junqueira Magalhães; Tomimori, Jane; Michalany, Nilceo Schwery; Nonogaki, Suely; Porro, Adriana Maria
2012-08-01
Among the papular-pruriginous dermatoses related to human immunodeficiency (HIV) infection, two entities remain poorly differentiated leading to confusion in their diagnosis: HIV-related pruritic papular eruption (HIV-PPE or prurigo) and eosinophilic folliculitis (HIV-EF). To establish histopathological and immunohistochemical parameters to differentiate between two conditions associated with HIV infection, the pruritic papular eruption (HIV-PPE) and eosinophilic folliculitis (HIV-EF). Clinically typical HIV-PPE (18 cases) and HIV-EF (10 cases) cases were compared with each other in terms of the following topics: clinical and laboratory features (gender, age, CD4+ cell and eosinophil count), histopathological features (hematoxylin-eosin and toluidine blue staining) and immunohistochemical features (anti-CD1a, anti-CD4, anti-CD7, anti-CD8, anti-CD15, anti-CD20, anti-CD30, anti-CD68/macrophage and anti-S-100 reactions). Among the HIV-EF patients, we found an intense perivascular and diffuse inflammatory infiltration compared with those patients with HIV-PPE. The tissue mast cell count by toluidine staining was higher in the HIV-EF patients, who also presented higher expression levels of CD15 (for eosinophils), CD4 (T helper), and CD7 (pan-T lymphocytes) than the HIV-PPE patients. Only quantitative differences and not qualitative differences were found. These data indicate that HIV-related PPE and EF could possibly be differentiated by histopathological and immunohistochemical findings in addition to clinical characteristics. In fact, these two inflammatory manifestations could be within the spectrum of the same disease because only quantitative, and not qualitative, differences were found. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Analog-to-Digital Conversion to Accommodate the Dynamics of Live Music in Hearing Instruments
Bahlmann, Frauke; Fulton, Bernadette
2012-01-01
Hearing instrument design focuses on the amplification of speech to reduce the negative effects of hearing loss. Many amateur and professional musicians, along with music enthusiasts, also require their hearing instruments to perform well when listening to the frequent, high amplitude peaks of live music. One limitation, in most current digital hearing instruments with 16-bit analog-to-digital (A/D) converters, is that the compressor before the A/D conversion is limited to 95 dB (SPL) or less at the input. This is more than adequate for the dynamic range of speech; however, this does not accommodate the amplitude peaks present in live music. The hearing instrument input compression system can be adjusted to accommodate for the amplitudes present in music that would otherwise be compressed before the A/D converter in the hearing instrument. The methodology behind this technological approach will be presented along with measurements to demonstrate its effectiveness. PMID:23258618
A corollary discharge maintains auditory sensitivity during sound production
NASA Astrophysics Data System (ADS)
Poulet, James F. A.; Hedwig, Berthold
2002-08-01
Speaking and singing present the auditory system of the caller with two fundamental problems: discriminating between self-generated and external auditory signals and preventing desensitization. In humans and many other vertebrates, auditory neurons in the brain are inhibited during vocalization but little is known about the nature of the inhibition. Here we show, using intracellular recordings of auditory neurons in the singing cricket, that presynaptic inhibition of auditory afferents and postsynaptic inhibition of an identified auditory interneuron occur in phase with the song pattern. Presynaptic and postsynaptic inhibition persist in a fictively singing, isolated cricket central nervous system and are therefore the result of a corollary discharge from the singing motor network. Mimicking inhibition in the interneuron by injecting hyperpolarizing current suppresses its spiking response to a 100-dB sound pressure level (SPL) acoustic stimulus and maintains its response to subsequent, quieter stimuli. Inhibition by the corollary discharge reduces the neural response to self-generated sound and protects the cricket's auditory pathway from self-induced desensitization.
Noise Prediction of NASA SR2 Propeller in Transonic Conditions
NASA Astrophysics Data System (ADS)
Gennaro, Michele De; Caridi, Domenico; Nicola, Carlo De
2010-09-01
In this paper we propose a numerical approach for noise prediction of high-speed propellers for Turboprop applications. It is based on a RANS approach for aerodynamic simulation coupled with Ffowcs Williams-Hawkings (FW-H) Acoustic Analogy for propeller noise prediction. The test-case geometry adopted for this study is the 8-bladed NASA SR2 transonic cruise propeller, and simulated Sound Pressure Levels (SPL) have been compared with experimental data available from Wind Tunnel and Flight Tests for different microphone locations in a range of Mach numbers between 0.78 and 0.85 and rotational velocities between 7000 and 9000 rpm. Results show the ability of this approach to predict noise to within a few dB of experimental data. Moreover corrections are provided to be applied to acoustic numerical results in order for them to be compared with Wind Tunnel and Flight Test experimental data, as well computational grid requirements and guidelines in order to perform complete aerodynamic and aeroacoustic calculations with highly competitive computational cost.
Structural and Optical Properties Studies Of Ar2+ Ion Implanted Mn Deposited GaAs
NASA Astrophysics Data System (ADS)
De Gennaro, Michele; Caridi, Domenico; de Nicola, Carlo
2010-09-01
In this paper we propose a numerical approach for noise prediction of high-speed propellers for Turboprop applications. It is based on a RANS approach for aerodynamic simulation coupled with Ffowcs Williams-Hawkings (FW-H) Acoustic Analogy for propeller noise prediction. The test-case geometry adopted for this study is the 8-bladed NASA SR2 transonic cruise propeller, and simulated Sound Pressure Levels (SPL) have been compared with experimental data available from Wind Tunnel and Flight Tests for different microphone locations in a range of Mach numbers between 0.78 and 0.85 and rotational velocities between 7000 and 9000 rpm. Results show the ability of this approach to predict noise to within a few dB of experimental data. Moreover corrections are provided to be applied to acoustic numerical results in order for them to be compared with Wind Tunnel and Flight Test experimental data, as well computational grid requirements and guidelines in order to perform complete aerodynamic and aeroacoustic calculations with highly competitive computational cost.
Guinea pig cochlear blood flow under definite sound exposure-hydrogen clearance measurement.
Meyer, P; Kuhl, K D; Schmidt, R; Grützmacher, W
1991-01-01
Blood flow measurements were carried out on 18 coloured guinea pigs (8 animals served as control group) before and during definite sound exposure (12 kHz, 110 dB SPL). The exposure time amounted to 60 min. The anaesthesia was carried out according to the following schedule: a mixture consisting of 70 mg alpha-chloralose/kg b.w. and 400 mg urethane/kg b.w. was injected intraperitoneally. The relaxation was performed by means of i.p. application of 3 mg Tricuran/kg b.w./h. The hydrogen clearance measurements (HCM) were carried out under artificial respiration with control of arterial pH, endexpiratory CO2 content, as well as blood pressure and body temperature. After a duration of noise exposure of 30-45 min the cochlear blood flow reached an average level of 80% of the initial point. This level remained mainly unchanged until the end of noise exposure (60 min). Our HMC's confirm Laser Doppler flowmetry findings.
NASA Astrophysics Data System (ADS)
Yamasaki, Nobuhiko; Tajima, Hirotoshi
2008-06-01
In the wake-rotor interaction fan noise, a number of the interacting modes at the blade passing frequency (BPF) and its harmonics are generated which are prescribed by the number of stator and rotor blades etc. In the present study, the dominant mode is tried to be suppressed by the secondary sound from the loudspeaker actuators. One of the novel features of the present system is the adoption of the control board with the Field Programmable Gate Array (FPGA) hardware and the LabVIEW software to synchronize the circumferentially installed loudspeaker actuators with the relative location of rotational blades under arbitrary fan rotational speeds. The experiments were conducted under the conditions of three rotational speeds of 2004, 3150, and 4002 [rpm]. The reduction in the sound pressure level (SPL) was observed for all three rotational speeds. The sound pressure level at the BPF was reduced approximately 13 [dB] for 2004 [rpm] case, but not so large reduction was attained for other cases probably due to the inefficiency of the loudspeaker actuators at high frequencies
Detection efficiency of auditory steady state evoked by modulated noise.
Santos, T S; Silva, J J; Lins, O G; Melges, D B; Tierra-Criollo, C J
2016-09-01
This study aimed to investigate the efficiency of Magnitude Squared Coherence (MSC) and Spectral F test (SFT) for the detection of auditory steady state responses (ASSR) obtained by amplitude-modulated noises. Twenty individuals (12 women) without any history of neurological or audiological diseases, aged from 18 to 59 years (mean ± standard deviation = 26.45 ± 3.9 years), who provided written informed consent, participated in the study. The Audiostim system was used for stimulating and ASSR recording. The tested stimuli were amplitude-modulated Wide-band noise (WBN), Low-band noise (LBN), High-band noise (HBN), Two-band noise (TBN) between 77 and 110 Hz, applied in intensity levels of 55, 45, and 25 dB sound pressure level (SPL). MSC and SFT, two statistical-based detection techniques, were applied with a significance level of 5%. Detection times and rates were compared using the Friedman test and Tukey-Kramer as post hoc analysis. Also based on the stimulation parameters (stimuli types and intensity levels) and detection techniques (MSC or SFT), 16 different pass/fail protocols, for which the true negatives (TN) were calculated. The median detection times ranged from 68 to 157s for 55 dB SPL, 68-99s for 45 dB SPL, and 84-118s for 25 dB SPL. No statistical difference was found between MSC and STF considering the median detection times (p > 0.05). The detection rates ranged from 100% to 55.6% in 55 dB SPL, 97.2%-38.9% in 45 dB SPL and 66.7%-8.3% in 25 dB SPL. Also for detection rates, no statistical difference was observed between MSC and STF (p > 0.05). True negatives (TN) above 90% were found for Protocols that employed WBN or HBN, at 55 dB SPL or that used WBN or HBN, at 45 dB SPL. For Protocols employing TBN, at 55 dB SPL or 45 dB SPL TN below 60% were found due to the low detection rates of stimuli that included low-band frequencies. The stimuli that include high-frequency content showed higher detection rates (>90%) and lower detection times (<3 min). The noise composed by two bands applied separately (TBN) is not feasible for clinical applications since it requires prolonging the exam duration, and also led to a reduced percentage of true negatives. On the other hand, WBN and HBN achieved high detection performance and high TN and should be investigated to implement pass/fail protocol for hearing screening with clinical population. Finally, both WBN and HBN seemed to be indifferent to the employed technique (SFT or MSC), which can be seen as another advantage of ASSR employment. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Ying; Tang, Yanli; Zhou, Zhijun; Ji, Eunkyung; Lopez, Gabriel P; Chi, Eva Y; Schanze, Kirk S; Whitten, David G
2010-08-03
Poly(phenylene ethyneylene) (PPE)-based cationic conjugated polyelectrolytes (CPEs) and cationic phenylene ethynylene oligomers (OPEs) exhibit broad-spectrum antimicrobial activity, and their main target is believed to be the cell membrane. To understand better how these antimicrobial molecules interact with membranes, a series of PPE-based CPEs and OPEs with different side chains were studied. Large unilamellar vesicles with lipid compositions mimicking those of mammalian or bacterial membranes were used as model membranes. Among the CPEs and OPEs tested, the anionic CPE, PPE-SO(3)(2-) and the smallest cationic OPE-1 are inactive against all vesicles. Other cationic CPEs and OPEs show significant membrane perturbation ability against bacterial membrane mimics but are inactive against a mammalian cell membrane mimic with the exception of PPE-DABCO and two end-only-functionalized OPEs, which also disrupted a mammalian cell membrane mimic. The results suggest that the phospholipid composition of vesicles dominates the interaction of CPE and OPE with lipid membranes.
The impact of OSHA regulations on nursing care cost and compliance.
Raltz, S; Kozarek, R A; Kim-Deobald, J; Pethigal, P; Moorhouse, M A
1994-01-01
The Occupational Safety and Health Administration (OSHA) requires health care facilities to protect employees from bloodborne pathogens. One of the mandates is to provide personal protective equipment (PPE) to employees at no cost to the employee. In this article, the authors explore the cost and compliance of implementing the new OSHA regulations for nursing staff assisting with colonoscopies over a 6-month period. The data were collected on a total of 461 procedures. The cost of implementing PPE for the nursing staff was $2.98 per procedure. The PPE available for the nursing staff included goggles, splash-proof gown, face mask, shoe covers, and latex gloves. The total cost of implementing the new regulations for the nursing staff assisting with colonoscopies was $2,747.56 and was projected to cost approximately $50,000 yearly if implemented for all GI procedures in the institution. Staff compliance rates for the five pieces of PPE ranged from 6.5 to 97.8%.
Shendell, Derek G; Jhaveri, Mehul; Nowakowski, Alexandra C H; Wozniak, Maryann E; Campbell, Jennifer K; Marshall, Elizabeth G; Kelly, Sarah W
2010-09-01
Through school-sponsored career and technical education programs in New Jersey, students work part-time during or after school in paid and unpaid structured learning experiences regulated by the New Jersey Department of Education. Schools submit information on "reportable incidents," injury or illness resulting in physician treatment. Incidents including reported use of personal protective equipment (PPE) were assessed; 1,600 incident reports (1999 to 2008) were received. Attributes such as type and severity, body parts affected, and PPE use for incidents occurring at school among students grades 9 to 12 or labeled as "adults" during school hours (n = 285) were analyzed. Older teens incurred more injuries. PPE use was consistently low across age and gender. Students most frequently experienced knife injuries involving fingers and hands. Results identified potential injury determinants and training and intervention topics such as PPE, and support development of an enhanced reporting form. Copyright 2010, SLACK Incorporated.
Quinn, Tyler; Kim, Jung-Hyun; Seo, Yongsuk; Coca, Aitor
2018-06-01
IntroductionPersonal protective equipment (PPE) recommended for use in West Africa during the Ebola outbreak increased risk for heat illness, and countermeasures addressing this issue would be valuable.Hypothesis/ProblemThe purpose of this study was to examine the physiological impact and heat perception of four different personal cooling devices (PCDs) under impermeable PPE during low-intensity exercise in a hot and humid environment using thermal manikin modeling and human testing. Six healthy male subjects walked on a treadmill in a hot/humid environment (32°C/92% relative humidity [RH]) at three metabolic equivalents (METs) for 60 minutes wearing PPE recommended for use in West Africa and one of four different personal cooling devices (PCDs; PCD1, PCD2, PCD3, and PCD4) or no PCD for control (CON). The same ensembles were tested with thermal manikin modeling software in the same conditions to compare the results. All PCDs seemed to reduce physiological heat stress characteristics when worn under PPE compared to CON. Both the manikin and human testing provided similar results in core temperature (Tc) and heat sensation (HS) in both magnitude and relationship. While the manikin and human data provided similar skin temperature (Tsk) characterization, Tsk estimation by the manikin seemed to be slightly over-estimated. Weight loss, as estimated by the manikin, was under-estimated compared to the human measurement. Personal cooling device use in conjunction with impermeable PPE may be advantageous in mitigating physiological and perceptual burdens of heat stress. Evaluation of PCDs worn under PPE can be done effectively via human or manikin testing; however, Tsk may be over-estimated and weight loss may be under-estimated. Thermal manikin testing of PCDs may provide fast and accurate information to persons recommending or using PCDs with PPE. QuinnT, KimJH, SeoY, CocaA. Comparison of thermal manikin modeling and human subjects' response during use of cooling devices under personal protective ensembles in the heat. Prehosp Disaster Med. 2018;33(3):279-287.
Xu, Xiaozhao; Li, Xu; Hu, Xingwang; Wu, Ting; Wang, Yi; Xu, Xuefeng; Zhang, Xinzhong; Han, Zhenhai
2017-01-01
Adventitious root formation is essential for the vegetative propagation of perennial woody plants. During the juvenile-to-adult phase change mediated by the microRNA156 (miR156), the adventitious rooting ability decreases dramatically in many species, including apple rootstocks. However, the mechanism underlying how miR156 affects adventitious root formation is unclear. In the present study, we showed that in the presence of the synthetic auxin indole-3-butyric acid (IBA), semi-lignified leafy cuttings from juvenile phase (Mx-J) and rejuvenated (Mx-R) Malus xiaojinensis trees exhibited significantly higher expression of miR156, PIN-FORMED1 (PIN1), PIN10, and rootless concerning crown and seminal roots-like (RTCS-like) genes, thus resulting in higher adventitious rooting ability than those from adult phase (Mx-A) trees. However, the expression of SQUAMOSA-PROMOTER BINDING PROTEIN-LIKE26 (SPL26) and some auxin response factor (ARF) gene family members were substantially higher in Mx-A than in Mx-R cuttings. The expression of NbRTCS-like but not NbPINs and NbARFs varied with miR156 expression in tobacco (Nicotiana benthamiana) plants transformed with 35S:MdMIR156a6 or 35S:MIM156 constructs. Overexpressing the miR156-resistant MxrSPL genes in tobacco confirmed the involvement of MxSPL20, MxSPL21&22, and MxSPL26 in adventitious root formation. Together, high expression of miR156 was necessary for auxin-induced adventitious root formation via MxSPL26, but independent of MxPINs and MxARFs expression in M. xiaojinensis leafy cuttings. PMID:28674551
Franzen, Daniel; Diacon, Andreas H; Freitag, Lutz; Schubert, Pawel T; Wright, Colleen A; Schuurmans, Macé M
2016-04-27
The evaluation of solitary pulmonary lesions (SPL) requires a balance between procedure-related morbidity and diagnostic yield, particularly in areas where tuberculosis (TB) is endemic. Data on ultrathin bronchoscopy (UB) for this purpose is limited. To evaluate feasibility and safety of UB compared to SB for diagnosis of SPL in a TB endemic region. In this prospective randomised trial we compared diagnostic yield and adverse events of UB with standard-size bronchoscopy (SB), both combined with fluoroscopy, in a cohort of patients with SPL located beyond the visible range of SB. We included 40 patients (mean age 55.2 years, 45 % male) with malignant SPL (n = 16; 40 %), tuberculous SPL (n = 11; 27.5 %) and other benign SPL (n = 13; 32.5 %). Mean procedure time in UB and SB was 30.6 and 26.0 min, respectively (p = 0.15). By trend, adverse events were recorded more often with UB than with SB (30.0 vs. 5.0 %, p = 0.091), including extensive coughing (n = 2), blocked working channel (n = 2), and arterial hypertension requiring therapeutic intervention (n = 1), all with UB. The overall diagnostic yield of UB compared to SB was 55.0 % vs. 80.0 %, respectively (p = 0.18). Sensitivity for the diagnosis of malignancy of UB and SB was 50.0 % and 62.5 %, respectively (p = 0.95). UB is not superior to SB for the evaluation of SPL in a region endemic with tuberculosis, when combined with fluoroscopic guidance only. ClinicalTrials.gov (Identifier: NCT02490059 ).
Development of an intraoperative gamma camera based on a 256-pixel mercuric iodide detector array
NASA Astrophysics Data System (ADS)
Patt, B. E.; Tornai, M. P.; Iwanczyk, J. S.; Levin, C. S.; Hoffman, E. J.
1997-06-01
A 256-element mercuric iodide (HgI/sub 2/) detector array has been developed which is intended for use as an intraoperative gamma camera (IOGC). The camera is specifically designed for use in imaging gamma-emitting radiopharmaceuticals (such as 99m-Tc labeled Sestamibi) incorporated into brain tumors in the intraoperative surgical environment. The system is intended to improve the success of tumor removal surgeries by allowing more complete removal of subclinical tumor cells without removal of excessive normal tissue. The use of HgI/sub 2/ detector arrays in this application facilitates construction of an imaging head that is very compact and has a high SNR. The detector is configured as a cross-grid array. Pixel dimensions are 1.25 mm squares separated by 0.25 mm. The overall dimension of the detector is 23.75 mm on a side. The detector thickness is 1 mm which corresponds to over 60% stopping at 140 keV. The array has good uniformity with average energy resolution of 5.2/spl plusmn/2.9% FWHM at 140 keV (best resolution was 1.9% FWHM). Response uniformity (/spl plusmn//spl sigma/) was 7.9%. A study utilizing realistic tumor phantoms (uptake ratio varied from 2:1 to 100:1) in background (1 mCi/l) was conducted. SNRs for the reasonably achievable uptake ratio of 50:1 were 5.61 /spl sigma/ with 1 cm of background depth ("normal tissue") and 2.74 /spl sigma/ with 4 cm of background for a 6.3 /spl mu/l tumor phantom (/spl sim/270 nCi at the time of the measurement).
Lei, Kai-Jian; Lin, Ya-Ming; Ren, Jing; Bai, Ling; Miao, Yu-Chen; An, Guo-Yong; Song, Chun-Peng
2016-01-01
The microRNA156 (miR156)-modulated SQUAMOSA PROMOTER BINDING PROTEIN-LIKE (SPL) is involved in diverse biological processes that include growth, development and metabolism. Here, we report that the Arabidopsis miR156 and SPL3 as regulators play important roles in phosphate (Pi) deficiency response. MiR156 was induced during Pi starvation whereas SPL3 expression was repressed. Phenotypes of reduced rhizosphere acidification and decreased anthocyanin accumulation were observed in 35S:MIM156 (via target mimicry) transgenic plants under Pi deficiency. The content and uptake of Pi in 35S:MIM156 Arabidopsis plants were increased compared with wild-type (Col-0 ecotype) plants. 35S:rSPL3 seedlings showed similar anthocyanin accumulation and Pi content phenotypes to those of 35S:MIM156 plants. Chromatin immunoprecipitation and an electrophoretic mobility shift assay indicated that the SPL3 protein directly bound to GTAC motifs in the PLDZ2, Pht1;5 and miR399f promoters. The expression of several Pi starvation-induced genes was increased in 35S:MIM156 and 35S:rSPL3 plants, including high-affinity Pi transporters, Mt4/TPS1-like genes and phosphatases. Collectively, our results suggest that the miR156-SPL3-Pht1;5 (-PLDZ2 and -miR399f) pathways constitute a component of the Pi deficiency-induced regulatory mechanism of Arabidopsis. © The Author 2015. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Mitroi, Daniel N; Deutschmann, André U; Raucamp, Maren; Karunakaran, Indulekha; Glebov, Konstantine; Hans, Michael; Walter, Jochen; Saba, Julie; Gräler, Markus; Ehninger, Dan; Sopova, Elena; Shupliakov, Oleg; Swandulla, Dieter; van Echten-Deckert, Gerhild
2016-11-24
The bioactive lipid sphingosine 1-phosphate (S1P) is a degradation product of sphingolipids that are particularly abundant in neurons. We have shown previously that neuronal S1P accumulation is toxic leading to ER-stress and an increase in intracellular calcium. To clarify the neuronal function of S1P, we generated brain-specific knockout mouse models in which S1P-lyase (SPL), the enzyme responsible for irreversible S1P cleavage was inactivated. Constitutive ablation of SPL in the brain (SPL fl/fl/Nes ) but not postnatal neuronal forebrain-restricted SPL deletion (SPL fl/fl/CaMK ) caused marked accumulation of S1P. Hence, altered presynaptic architecture including a significant decrease in number and density of synaptic vesicles, decreased expression of several presynaptic proteins, and impaired synaptic short term plasticity were observed in hippocampal neurons from SPL fl/fl/Nes mice. Accordingly, these mice displayed cognitive deficits. At the molecular level, an activation of the ubiquitin-proteasome system (UPS) was detected which resulted in a decreased expression of the deubiquitinating enzyme USP14 and several presynaptic proteins. Upon inhibition of proteasomal activity, USP14 levels, expression of presynaptic proteins and synaptic function were restored. These findings identify S1P metabolism as a novel player in modulating synaptic architecture and plasticity.
A rapid fluorescence assay for sphingosine-1-phosphate lyase enzyme activity.
Bandhuvula, Padmavathi; Fyrst, Henrik; Saba, Julie D
2007-12-01
Sphingosine-1-phosphate (S1P) lyase (SPL) catalyzes the conversion of S1P to ethanolamine phosphate and hexadecenal. This enzyme plays diverse roles in physiology and disease and, thus, may be useful as a disease marker and/or drug target. Unfortunately, the radioisotope-based assay currently used to quantify SPL activity is suboptimal. We have devised an assay using a commercially available omega(7-nitro-2-1,3-benzoxadiazol-4-yl)-d-erythro (NBD)-labeled fluorescent substrate. Alternatively, we provide a method for synthesis of the substrate from NBD-sphingosine. Enzyme activity is determined by following the formation of NBD-aldehyde product, which is isolated from unreacted substrate by lipid extraction and quantified after separation by HPLC using a C18 column. A fluorescent NBD-C18-sphingosine internal standard is used to control for extraction efficiency. The reaction is linear over 20 min and total protein concentrations of 20-200 mg/l. The sensitivity of the fluorescence assay is comparable to or better than that of the radioactive assay, and SPL levels as low as 8 pmol/mg/min were readily detected. Semicarbazide, a nonspecific SPL inhibitor, reduced SPL activity in vitro by approximately 70% using both standard and fluorescence methods. Product inhibition was not observed using ethanolamine phosphate and a commercially available source of hexadecenal. This method is suitable for quantifying SPL activity in a variety of cell and tissue sources.
Hunter, Eric J.; Švec, Jan G.; Titze, Ingo R.
2016-01-01
Frequency and intensity ranges (in true dB SPL re 20 μPa at 1 meter) of voice production in trained and untrained vocalists were compared to the perceived dynamic range (phons) and units of loudness (sones) of the ear. Results were reported in terms of standard Voice Range Profiles (VRPs), perceived VRPs (as predicted by accepted measures of auditory sensitivities), and a new metric labeled as an Overall Perceptual Level Construct. Trained classical singers made use of the most sensitive part of the hearing range (around 3–4 KHz) through the use of the singer’s formant. When mapped onto the contours of equal-loudness (depicting non-uniform spectral and dynamic sensitivities of the auditory system), the formant is perceived at an even higher sound level, as measured in phons, than a flat or A-weighted spectrum would indicate. The contributions of effects like the singer’s formant and the sensitivities of the auditory system helped the trained singers produce 20–40 percent more units of loudness, as measured in sones, than the untrained singers. Trained male vocalists had a maximum Overall Perceptual Level Construct that was 40% higher than the untrained male vocalists. While the A-weighted spectrum (commonly used in VRP measurement) is a reasonable first order approximation of auditory sensitivities, it misrepresents the most salient part of the sensitivities (where the singer’s formant is found) by nearly 10 dB. PMID:16325373
Alsaggaf, Mohammed S; Moussa, Shaaban H; Tayel, Ahmed A
2017-06-01
Fish are generous sources for providing man with his essential nutritional requirements, but the extreme susceptibility to quality deterioration hinders their optimal usage and storage. Natural derivatives are always the perfect alternatives for food preservation. The application of fungal chitosan (Ch), from Aspergillus niger, and pomegranate peel extract (PPE), in coating films for Nile tilapia (Oreochromis niloticus) fillets preservation and maintaining their microbiological, chemical and sensorial quality during cooled storage at 4°C for 30days, was investigated. Fish fillet were coated with Ch (2%) and combined Ch+PPE, at PPE percentages of 0.5, 1.0, 1.5 and 2.0%. Fillets coating resulted in sharp decrease of the entire microbial counts during storage; the increased concentrations from PPE strengthened coating film antimicrobial activity. Additionally, fillets coating could retard the chemical spoilage parameters increasing, i.e. nitrogen volatile base (TVB-N), peroxide value (PV) and reactive substances of thiobarbituric acid (TBARS), during storage period. The sensory evaluation indicated higher preferences for the odor, texture, color and overall quality of coated samples. Fish fillets coating with Ch and Ch+PPE could be recommended for shelf life extension and maintaining the microbiological, chemical and sensorial quality through the application of safe preservatives from natural origins. Copyright © 2017 Elsevier B.V. All rights reserved.
Andrade-Rivas, Federico; Rother, Hanna-Andrea
2015-10-01
The high exposure risks of workers to herbicides in low- and middle-income countries is an important public health concern because of the potential resulting negative impacts on workers' health. This study investigated workers' personal protective equipment (PPE) compliance as a risk mitigation measure; particularly workers who apply herbicides for Working for Water (WfW) - a South African invasive alien vegetation control programme. The study aim was to understand workers' low PPE compliance by analysing their risk perceptions of herbicide use, working conditions and socio-cultural context. Research methods included ethnographic observations, informal interviews, visual media, questionnaires and a focus group. Study results indicated that low PPE compliance persists despite workers' awareness of herbicide exposure risks and as a result of the influence from workers' socio-cultural context (i.e. gender dynamics and social status), herbicide risk perceptions and working conditions (i.e. environmental and logistical). Interestingly, teams comprised of mostly women had the highest compliance rate. These findings highlighted that given the complexity of PPE compliance, especially in countries with several economic and social constraints, exposure reduction interventions should not rely solely on PPE use promotion. Instead, other control strategies requiring less worker input for effectiveness should be implemented, such as elimination and substitution of highly hazardous pesticides, and altering application methods. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Physiological Evaluation of Personal Protective Ensembles Recommended for Use in West Africa.
Coca, Aitor; Quinn, Tyler; Kim, Jung-Hyun; Wu, Tianzhou; Powell, Jeff; Roberge, Raymond; Shaffer, Ronald
2017-10-01
Personal protective equipment (PPE) provides health care workers with a barrier to prevent human contact with viruses like Ebola and potential transmission of the disease. However, PPE can also introduce an additional physiological burden from potentially increased heat stress. This study evaluated the human physiological and subjective responses to continuous light exercise within environmental conditions similar to those in West Africa while wearing 3 different, commonly used PPE ensembles (E1, E2, and E3). Six healthy individuals were tested in an environmental chamber (32°C, 92% relative humidity) while walking (3 METs, 2.5 mph, 0% incline) on a treadmill for 60 minutes. All subjects wore medical scrubs and PPE items. E1 also had a face shield and fluid-resistant surgical gown; E2 additionally included goggles, coverall, and separate hood; and E3 also contained a highly impermeable coverall, separate hood, and surgical mask cover over the N95 respirator. Heart rate and core temperature at the end of the exercise were significantly higher for E2 and E3 than for E1. Subjective perceptions of heat and exertion were significantly higher for E2 and E3 than for E1. Heat stress and PPE training, as well as the implementation of a work-to-rest ratio that avoids dehydration and possible heat stress issues, are recommended. (Disaster Med Public Health Preparedness. 2017;11:580-586).
NASA Astrophysics Data System (ADS)
Mi, Hongyu; Guan, Mingming; Liu, Jilin; Shan, Hongyan; Fei, Qiang; Huan, Yanfu; Feng, Guodong
2017-04-01
In this work, a turn on fluorescent sensor, based on Hg2 + coordination conjugated polymer, was developed to detect cysteine-containing compounds. The fluorescence of conjugated polymer (poly(2,5-bis (sodium 4-oxybutyrate) -1,4 - phenylethynylene-alt-1,4-phenyleneethynylene; PPE-OBS) would be quenched by Hg2 + because of the coordination-induced aggregation and electron transfers of PPE-OBS toward Hg2 +. When there were some cysteine-containing compounds in PPE-OBS-Hg2 + system, the fluorescence of PPE-OBS would be recovered. It indicated that the PPE-OBS-Hg2 + system could be used to detect cysteine-containing compounds. Under the optimized conditions, the experiment results showed that there were particularly linear range, high sensitivity and selectivity over other amino acids. The limit of detection (LOD) of cysteine (Cys), homocysteine (Hcy) and glutathione (GSH) were 0.725 μmol L- 1, 0.982 μmol L- 1 and 1.21 μmol L- 1 by using this sensor. In addition, Cys standard recovery in several green tea drink and honey samples was also demonstrated. The recovery of Cys was range from 96.3 to 105.0% and RSD was less than 3.25%. The satisfactory results demonstrated that the proposed method could be as a potential fluorescent method for determining cysteine-containing compounds in real samples.
Mechanistic studies of the radical SAM enzyme spore photoproduct lyase (SPL).
Li, Lei
2012-11-01
Spore photoproduct lyase (SPL) repairs a special thymine dimer 5-thyminyl-5,6-dihydrothymine, which is commonly called spore photoproduct or SP at the bacterial early germination phase. SP is the exclusive DNA photo-damage product in bacterial endospores; its generation and swift repair by SPL are responsible for the spores' extremely high UV resistance. The early in vivo studies suggested that SPL utilizes a direct reversal strategy to repair the SP in the absence of light. The research in the past decade further established SPL as a radical SAM enzyme, which utilizes a tri-cysteine CXXXCXXC motif to harbor a [4Fe-4S] cluster. At the 1+ oxidation state, the cluster provides an electron to the S-adenosylmethionine (SAM), which binds to the cluster in a bidentate manner as the fourth and fifth ligands, to reductively cleave the CS bond associated with the sulfonium ion in SAM, generating a reactive 5'-deoxyadenosyl (5'-dA) radical. This 5'-dA radical abstracts the proR hydrogen atom from the C6 carbon of SP to initiate the repair process; the resulting SP radical subsequently fragments to generate a putative thymine methyl radical, which accepts a back-donated H atom to yield the repaired TpT. SAM is suggested to be regenerated at the end of each catalytic cycle; and only a catalytic amount of SAM is needed in the SPL reaction. The H atom source for the back donation step is suggested to be a cysteine residue (C141 in Bacillus subtilis SPL), and the H-atom transfer reaction leaves a thiyl radical behind on the protein. This thiyl radical thus must participate in the SAM regeneration process; however how the thiyl radical abstracts an H atom from the 5'-dA to regenerate SAM is unknown. This paper reviews and discusses the history and the latest progress in the mechanistic elucidation of SPL. Despite some recent breakthroughs, more questions are raised in the mechanistic understanding of this intriguing DNA repair enzyme. This article is part of a Special Issue entitled: Radical SAM enzymes and Radical Enzymology. Copyright © 2011 Elsevier B.V. All rights reserved.
Xu, Jingjing; Cox, Robyn M
2014-09-01
The Four Alternative Auditory Feature test (FAAF) is a word-based closed-set speech recognition test. Because the original test materials were recorded in British English dialect, it is not appropriate for use in the United States. The purpose of this study was to produce an American dialect FAAF (AFAAF). The AFAAF materials spoken by a native American-English speaking male were recorded and digitally edited. In the validation study, the AFAAF was administered monaurally at five signal-to-noise ratios (SNRs) in both ears for each listener. A total of 20 young adults with normal hearing participated in the validation study. For each participant, speech recognition scores were collected in one session. The speech level was fixed at 70 dB SPL and the steady-state talker-matched noise level was varied, resulting in five SNRs from -15 to -5 dB. One full list (80 words) was used for each SNR. For each participant, a performance-intensity (PI) function was fit to the discrete mean percent correct scores for the five SNRs according to a best-fit, three-parameter sigmoid function. In addition, scores for the left and right ears were compared to examine test-retest reliability. RESULTS show that the slope of the PI function is 6% per dB, the mean test-retest difference scores for the five SNRs are within 3 rationalized arcsine units (rau), and the 95% critical difference for the 80-word scores is 12 rau. Compared with the FAAF, the slope of the PI function for the AFAAF is slightly less steep. Test-retest reliability of the AFAAF is at least equal to that of the FAAF. It is concluded that the AFAAF is similar but not identical to the FAAF. The AFAAF is now available for measuring speech recognition performance in listeners who use American English as a native language. American Academy of Audiology.
Marmel, Frederic; Marrufo-Pérez, Miriam I; Heeren, Jan; Ewert, Stephan; Lopez-Poveda, Enrique A
2018-06-14
The detection of high-frequency spectral notches has been shown to be worse at 70-80 dB sound pressure level (SPL) than at higher levels up to 100 dB SPL. The performance improvement at levels higher than 70-80 dB SPL has been related to an 'ideal observer' comparison of population auditory nerve spike trains to stimuli with and without high-frequency spectral notches. Insofar as vertical localization partly relies on information provided by pinna-based high-frequency spectral notches, we hypothesized that localization would be worse at 70-80 dB SPL than at higher levels. Results from a first experiment using a virtual localization set-up and non-individualized head-related transfer functions (HRTFs) were consistent with this hypothesis, but a second experiment using a free-field set-up showed that vertical localization deteriorates monotonically with increasing level up to 100 dB SPL. These results suggest that listeners use different cues when localizing sound sources in virtual and free-field conditions. In addition, they confirm that the worsening in vertical localization with increasing level continues beyond 70-80 dB SPL, the highest levels tested by previous studies. Further, they suggest that vertical localization, unlike high-frequency spectral notch detection, does not rely on an 'ideal observer' analysis of auditory nerve spike trains. Copyright © 2018 Elsevier B.V. All rights reserved.
Preston, Jill C; Jorgensen, Stacy A; Orozco, Rebecca; Hileman, Lena C
2016-02-01
Duplicated petunia clade-VI SPL genes differentially promote the timing of inflorescence and flower development, and leaf initiation rate. The timing of plant reproduction relative to favorable environmental conditions is a critical component of plant fitness, and is often associated with variation in plant architecture and habit. Recent studies have shown that overexpression of the microRNA miR156 in distantly related annual species results in plants with perennial characteristics, including late flowering, weak apical dominance, and abundant leaf production. These phenotypes are largely mediated through the negative regulation of a subset of genes belonging to the SQUAMOSA PROMOTER BINDING PROTEIN-LIKE (SPL) family of transcription factors. In order to determine how and to what extent paralogous SPL genes have partitioned their roles in plant growth and development, we functionally characterized petunia clade-VI SPL genes under different environmental conditions. Our results demonstrate that PhSBP1and PhSBP2 differentially promote discrete stages of the reproductive transition, and that PhSBP1, and possibly PhCNR, accelerates leaf initiation rate. In contrast to the closest homologs in annual Arabidopsis thaliana and Mimulus guttatus, PhSBP1 and PhSBP2 transcription is not mediated by the gibberellic acid pathway, but is positively correlated with photoperiod and developmental age. The developmental functions of clade-VI SPL genes have, thus, evolved following both gene duplication and speciation within the core eudicots, likely through differential regulation and incomplete sub-functionalization.
Bernal, María; Casero, David; Singh, Vasantika; Wilson, Grandon T.; Grande, Arne; Yang, Huijun; Dodani, Sheel C.; Pellegrini, Matteo; Huijser, Peter; Connolly, Erin L.; Merchant, Sabeeha S.; Krämer, Ute
2012-01-01
The transition metal copper (Cu) is essential for all living organisms but is toxic when present in excess. To identify Cu deficiency responses comprehensively, we conducted genome-wide sequencing-based transcript profiling of Arabidopsis thaliana wild-type plants and of a mutant defective in the gene encoding SQUAMOSA PROMOTER BINDING PROTEIN-LIKE7 (SPL7), which acts as a transcriptional regulator of Cu deficiency responses. In response to Cu deficiency, FERRIC REDUCTASE OXIDASE5 (FRO5) and FRO4 transcript levels increased strongly, in an SPL7-dependent manner. Biochemical assays and confocal imaging of a Cu-specific fluorophore showed that high-affinity root Cu uptake requires prior FRO5/FRO4-dependent Cu(II)-specific reduction to Cu(I) and SPL7 function. Plant iron (Fe) deficiency markers were activated in Cu-deficient media, in which reduced growth of the spl7 mutant was partially rescued by Fe supplementation. Cultivation in Cu-deficient media caused a defect in root-to-shoot Fe translocation, which was exacerbated in spl7 and associated with a lack of ferroxidase activity. This is consistent with a possible role for a multicopper oxidase in Arabidopsis Fe homeostasis, as previously described in yeast, humans, and green algae. These insights into root Cu uptake and the interaction between Cu and Fe homeostasis will advance plant nutrition, crop breeding, and biogeochemical research. PMID:22374396
Pedraza-Reyes, M; Gutiérrez-Corona, F; Nicholson, W L
1994-01-01
Bacterial spores are highly resistant to killing by UV radiation and exhibit unique DNA photochemistry. UV irradiation of spore DNA results in formation of spore photoproduct (SP), the thymine dimer 5-thyminyl-5,6-dihydrothymine. Repair of SP occurs during germination of Bacillus subtilis spores by two distinct routes, either by the general nucleotide excision repair (uvr) pathway or by a novel SP-specific monomerization reaction mediated by the enzyme SP lyase, which is encoded by the spl gene. Repair of SP occurs early in spore germination and is independent of de novo protein synthesis, suggesting that the SP repair enzymes are synthesized during sporulation and are packaged in the dormant spore. To test this hypothesis, the expression of a translational spl-lacZ fusion integrated at the spl locus was monitored during B. subtilis growth and sporulation. beta-Galactosidase expression from the spl-lacZ fusion was silent during vegetative growth and was not DNA damage inducible, but it was activated at morphological stage III of sporulation specifically in the forespore compartment, coincident with activation of expression of the stage III marker enzyme glucose dehydrogenase. Expression of the spl-lacZ fusion was shown to be dependent upon the sporulation-specific RNA polymerase containing the sigma-G factor (E sigma G), as spl-lacZ expression was abolished in a mutant harboring a deletion in the sigG gene and restored by expression of the sigG gene in trans. Primer extension analysis of spl mRNA revealed a major extension product initiating upstream from a small open reading frame of unknown function which precedes spl, and it revealed two other shorter minor extension products. All three extension products were present in higher quantities during sporulation and after sigG induction. The three putative transcripts are all preceded by sequences which share homology with the consensus sigma-G factor-type promoter sequence, but in vitro transcription by purified sigma-G RNA polymerase was detected only from the promoter corresponding to the major extension product. The open reading frame-spl operon therefore appears to be an additional member of the sigma-G regulon, which also includes as members the small, acid-soluble spore proteins which are in large part responsible for spore DNA photochemistry. Therefore, sporulating bacteria appear to coordinately regulate genes whose products not only alter spore DNA photochemistry but also repair the major spore-specific photoproduct during germination Images PMID:8021181
Code of Federal Regulations, 2011 CFR
2011-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... conjunction with engineering controls, guards, and safe work practices and procedures. 2. Assessment and... are likely to arise under foreseeable work activity conditions and to match employee PPE to the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... conjunction with engineering controls, guards, and safe work practices and procedures. 2. Assessment and... are likely to arise under foreseeable work activity conditions and to match employee PPE to the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... conjunction with engineering controls, guards, and safe work practices and procedures. 2. Assessment and... are likely to arise under foreseeable work activity conditions and to match employee PPE to the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... conjunction with engineering controls, guards, and safe work practices and procedures. 2. Assessment and... are likely to arise under foreseeable work activity conditions and to match employee PPE to the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... the first week of a response. Protective measures addressed in the guidance include medical countermeasures (i.e., drugs, vaccine), personal protective equipment (PPE), and other possible work practices. A...), including more specificity regarding the use of personal protective equipment (PPE). In addition, a number...
The Influence of Students' Gender on Equity in Peer Physical Examination: A Qualitative Study
ERIC Educational Resources Information Center
Vnuk, Anna K.; Wearn, Andy; Rees, Charlotte E.
2017-01-01
Peer Physical Examination (PPE) is an educational tool used globally for learning early clinical skills and anatomy. In quantitative research, there are differences in students' preferences and actual participation in PPE by gender. This novel study qualitatively explores the effect that gender has on medical students' experiences of learning…
[Prevalence of genital anomalies in young football players].
Mónaco, M; Verdugo, F; Bodell, M; Avendaño, E; Til, L; Drobnic, F
2015-01-01
The purpose of genital examination (GE) during the Pre-participation Physical Examination (PPE) is to identify the state of maturity, and rule out any genital pathology. To describe genital anomalies (GA) and estimate the awareness of GE in young football players. A descriptive, cross-sectional study was conducted in 280 elite football players from the results of PPE over two seasons. There was a detection rate of 5.4% GA, with varicocele being 3.2%, and of which only 13% were aware of their condition. Although this study shows a low incidence of genital abnormality in the study population, only 13% were aware of the GE prior to assessment. These findings demonstrate a low incidence of GA in this population. While GE is recommended during PPE, it is not a routine practice performed by family doctors or sports medicine specialists. This article attempts to raise awareness of the importance of GE in PPE as a preventive health strategy. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Lipopeptide biosurfactants from Paenibacillus polymyxa inhibit single and mixed species biofilms.
Quinn, Gerry A; Maloy, Aaron P; McClean, Stephen; Carney, Brian; Slater, John W
2012-01-01
Although biofilms are recognised as important in microbial colonisation, solutions to their inhibition are predominantly based on planktonic assays. These solutions have limited efficacy against biofilms. Here, a series of biofilm-orientated tests were used to identify anti-biofilm compounds from marine micro-flora. This led to the isolation of a complex of anti-biofilm compounds from an extract of Paenibacillus polymyxa (PPE). A combination of rpHPLC and mass spectrometry identified the principle components of PPE as fusaricidin B (LI-FO4b) and polymyxin D1, with minor contributions from surfactins. This complex (PPE) reduced the biofilm biomass of Bacillus subtilis, Micrococcus luteus, Pseudomonas aeruginosa, Staphylococcus aureus and Streptococcus bovis. In contrast, ampicillin was only effective against S. aureus. PPE also inhibited a self-assembling marine biofilm (SAMB) in co-incubation assays by 99.3% ± 1.9 and disrupted established SAMB by 72.4% ± 4.4, while ampicillin showed no significant reduction. The effectiveness of this complex of lipopeptides against single and multispecies biofilms suggests a future role in biofilm prevention strategies.
NASA Astrophysics Data System (ADS)
Cervantes-Espinosa, L. M.; Castillo-Alvarado, F. de L.; Lara-Hernández, G.; Cruz-Orea, A.; Mendoza-Alvarez, J. G.; Valcárcel, J. P.; García-Quiroz, A.
2012-11-01
Thermal properties of liquids used in the automobile industry such as engine oil, antifreeze, and a liquid for windshield wipers were obtained using the photopyroelectric (PPE) technique. The inverse PPE configuration was used in order to obtain the thermal effusivity of the liquid samples. The theoretical equation for the PPE signal in this configuration, as a function of the incident light modulation frequency, was fitted to the experimental data in order to obtain the thermal effusivity of these samples. Also, the back PPE configuration was used to obtain the thermal diffusivity of these liquids; this thermal parameter was obtained by fitting the theoretical equation for this configuration, as a function of the sample thickness (called the thermal wave resonator cavity), to the experimental data. All measurements were done at room temperature. A complete thermal characterization of these liquids used in the automobile industry was achieved by the relationship between the obtained thermal diffusivities and thermal effusivities with their thermal conductivities and volumetric heat capacities. The obtained results are compared with the thermal properties of similar liquids.
Martín Rodríguez, Francisco; Fernández Pérez, Cristina; Castro Villamor, Miguel; Martín Conty, José Luis; Arnillas Gómez, Pedro; Casado Vicente, Verónica
2018-01-01
Our aim was to determine the usefulness of level D personal protective equipment (PPE) in safeguarding health care staff who perform cardiopulmonary resuscitation (CPR). Quasi-experimental, uncontrolled trial in 96 volunteers chosen randomly and stratified by sex, level of training, and professional category. The subjects were selected from a convenience sample of 164 nurses, physicians, and students of nursing and medicine (40 men [41.66%] and 56 women [58.33%]). The mean (SD) age was 31 (11) years. The Conconi test was used to determine heart rate (HR) at the anaerobic threshold on a cycle ergometer. That HR was then compared to each volunteer's maximum HR during performance of CPR while wearing PPE. While the volunteers were performing CPR, 46.9% of them surpassed their maximum recommendable HR recorded during the cycle ergometer test. We found that performing CPR while wearing level D PPE requires intense physical effort. Special situations should be taken into consideration when developing protocols for situations that require staff to wear PPE. Staff who must perform CPR under these conditions should be given specific training.
Ahn, Junho; Choi, Yeonweon; Lee, Ae-Ree; Lee, Joon-Hwa; Jung, Jong Hwa
2016-03-21
Using duplex DNA-AuNP aggregates, a sequence-specific DNA-binding protein, SQUAMOSA Promoter-binding-Like protein 12 (SPL-12), was directly determined by SPL-12-duplex DNA interaction-based colorimetric actions of DNA-Au assemblies. In order to prepare duplex DNA-Au aggregates, thiol-modified DNA 1 and DNA 2 were attached onto the surface of AuNPs, respectively, by the salt-aging method and then the DNA-attached AuNPs were mixed. Duplex-DNA-Au aggregates having the average size of 160 nm diameter and the maximum absorption at 529 nm were able to recognize SPL-12 and reached the equivalent state by the addition of ∼30 equivalents of SPL-12 accompanying a color change from red to blue with a red shift of the maximum absorption at 570 nm. As a result, the aggregation size grew to about 247 nm. Also, at higher temperatures of the mixture of duplex-DNA-Au aggregate solution and SPL-12, the equivalent state was reached rapidly. On the contrary, in the control experiment using Bovine Serum Albumin (BSA), no absorption band shift of duplex-DNA-Au aggregates was observed.
Control of Neural Daughter Cell Proliferation by Multi-level Notch/Su(H)/E(spl)-HLH Signaling
Bivik, Caroline; MacDonald, Ryan B.; Gunnar, Erika; Mazouni, Khalil; Schweisguth, Francois; Thor, Stefan
2016-01-01
The Notch pathway controls proliferation during development and in adulthood, and is frequently affected in many disorders. However, the genetic sensitivity and multi-layered transcriptional properties of the Notch pathway has made its molecular decoding challenging. Here, we address the complexity of Notch signaling with respect to proliferation, using the developing Drosophila CNS as model. We find that a Notch/Su(H)/E(spl)-HLH cascade specifically controls daughter, but not progenitor proliferation. Additionally, we find that different E(spl)-HLH genes are required in different neuroblast lineages. The Notch/Su(H)/E(spl)-HLH cascade alters daughter proliferation by regulating four key cell cycle factors: Cyclin E, String/Cdc25, E2f and Dacapo (mammalian p21CIP1/p27KIP1/p57Kip2). ChIP and DamID analysis of Su(H) and E(spl)-HLH indicates direct transcriptional regulation of the cell cycle genes, and of the Notch pathway itself. These results point to a multi-level signaling model and may help shed light on the dichotomous proliferative role of Notch signaling in many other systems. PMID:27070787
A synthetic promoter library for constitutive gene expression in Lactobacillus plantarum.
Rud, Ida; Jensen, Peter Ruhdal; Naterstad, Kristine; Axelsson, Lars
2006-04-01
A synthetic promoter library (SPL) for Lactobacillus plantarum has been developed, which generalizes the approach for obtaining synthetic promoters. The consensus sequence, derived from rRNA promoters extracted from the L. plantarum WCFS1 genome, was kept constant, and the non-consensus sequences were randomized. Construction of the SPL was performed in a vector (pSIP409) previously developed for high-level, inducible gene expression in L. plantarum and Lactobacillus sakei. A wide range of promoter strengths was obtained with the approach, covering 3-4 logs of expression levels in small increments of activity. The SPL was evaluated for the ability to drive beta-glucuronidase (GusA) and aminopeptidase N (PepN) expression. Protein production from the synthetic promoters was constitutive, and the most potent promoters gave high protein production with levels comparable to those of native rRNA promoters, and production of PepN protein corresponding to approximately 10-15 % of the total cellular protein. High correlation was obtained between the activities of promoters when tested in L. sakei and L. plantarum, which indicates the potential of the SPL for other Lactobacillus species. The SPL enables fine-tuning of stable gene expression for various applications in L. plantarum.
Geers, Ann E; Davidson, Lisa S; Uchanski, Rosalie M; Nicholas, Johanna G
2013-09-01
This study documented the ability of experienced pediatric cochlear implant (CI) users to perceive linguistic properties (what is said) and indexical attributes (emotional intent and talker identity) of speech, and examined the extent to which linguistic (LSP) and indexical (ISP) perception skills are related. Preimplant-aided hearing, age at implantation, speech processor technology, CI-aided thresholds, sequential bilateral cochlear implantation, and academic integration with hearing age-mates were examined for their possible relationships to both LSP and ISP skills. Sixty 9- to 12-year olds, first implanted at an early age (12 to 38 months), participated in a comprehensive test battery that included the following LSP skills: (1) recognition of monosyllabic words at loud and soft levels, (2) repetition of phonemes and suprasegmental features from nonwords, and (3) recognition of key words from sentences presented within a noise background, and the following ISP skills: (1) discrimination of across-gender and within-gender (female) talkers and (2) identification and discrimination of emotional content from spoken sentences. A group of 30 age-matched children without hearing loss completed the nonword repetition, and talker- and emotion-perception tasks for comparison. Word-recognition scores decreased with signal level from a mean of 77% correct at 70 dB SPL to 52% at 50 dB SPL. On average, CI users recognized 50% of key words presented in sentences that were 9.8 dB above background noise. Phonetic properties were repeated from nonword stimuli at about the same level of accuracy as suprasegmental attributes (70 and 75%, respectively). The majority of CI users identified emotional content and differentiated talkers significantly above chance levels. Scores on LSP and ISP measures were combined into separate principal component scores and these components were highly correlated (r = 0.76). Both LSP and ISP component scores were higher for children who received a CI at the youngest ages, upgraded to more recent CI technology and had lower CI-aided thresholds. Higher scores, for both LSP and ISP components, were also associated with higher language levels and mainstreaming at younger ages. Higher ISP scores were associated with better social skills. Results strongly support a link between indexical and linguistic properties in perceptual analysis of speech. These two channels of information appear to be processed together in parallel by the auditory system and are inseparable in perception. Better speech performance, for both linguistic and indexical perception, is associated with younger age at implantation and use of more recent speech processor technology. Children with better speech perception demonstrated better spoken language, earlier academic mainstreaming, and placement in more typically sized classrooms (i.e., >20 students). Well-developed social skills were more highly associated with the ability to discriminate the nuances of talker identity and emotion than with the ability to recognize words and sentences through listening. The extent to which early cochlear implantation enabled these early-implanted children to make use of both linguistic and indexical properties of speech influenced not only their development of spoken language, but also their ability to function successfully in a hearing world.
Optimization of programming parameters in children with the advanced bionics cochlear implant.
Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L
2012-05-01
Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal-to-noise ratio). Outcomes were analyzed using a paired t-test and a mixed-model repeated measures analysis of variance (ANOVA). T-levels set 10 CUs below "soft" resulted in significantly lower detection thresholds for all six Ling sounds and FM tones at 250, 1000, 3000, 4000, and 6000 Hz. When comparing programs differing by IDR and sensitivity, a 50 dB IDR with a 0 sensitivity setting showed significantly poorer thresholds for low frequency FM tones and voiced Ling sounds. Analysis of group mean scores for CNC words in quiet or HINT-C sentences in noise indicated no significant differences across IDR/sensitivity settings. Individual data, however, showed significant differences between IDR/sensitivity programs in noise; the optimal program differed across participants. In pediatric recipients of the Advanced Bionics cochlear implant device, manually setting T-levels with ascending loudness judgments should be considered when possible or when low-level sounds are inaudible. Study findings confirm the need to determine program settings on an individual basis as well as the importance of speech recognition verification measures in both quiet and noise. Clinical guidelines are suggested for selection of programming parameters in both young and older children. American Academy of Audiology.
Geers, Ann; Davidson, Lisa; Uchanski, Rosalie; Nicholas, Johanna
2013-01-01
Objectives This study documented the ability of experienced pediatric cochlear implant (CI) users to perceive linguistic properties (what is said) and indexical attributes (emotional intent and talker identity) of speech, and examined the extent to which linguistic (LSP) and indexical (ISP) perception skills are related. Pre-implant aided hearing, age at implantation, speech processor technology, CI-aided thresholds, sequential bilateral cochlear implantation, and academic integration with hearing age-mates were examined for their possible relationships to both LSP and ISP skills. Design Sixty 9–12 year olds, first implanted at an early age (12–38 months), participated in a comprehensive test battery that included the following LSP skills: 1) recognition of monosyllabic words at loud and soft levels, 2) repetition of phonemes and suprasegmental features from non-words, and 3) recognition of keywords from sentences presented within a noise background, and the following ISP skills: 1) discrimination of male from female and female from female talkers and 2) identification and discrimination of emotional content from spoken sentences. A group of 30 age-matched children without hearing loss completed the non-word repetition, and talker- and emotion-perception tasks for comparison. Results Word recognition scores decreased with signal level from a mean of 77% correct at 70 dB SPL to 52% at 50 dB SPL. On average, CI users recognized 50% of keywords presented in sentences that were 9.8 dB above background noise. Phonetic properties were repeated from non-word stimuli at about the same level of accuracy as suprasegmental attributes (70% and 75%, respectively). The majority of CI users identified emotional content and differentiated talkers significantly above chance levels. Scores on LSP and ISP measures were combined into separate principal component scores and these components were highly correlated (r = .76). Both LSP and ISP component scores were higher for children who received a CI at the youngest ages, upgraded to more recent CI technology and had lower CI-aided thresholds. Higher scores, for both LSP and ISP components, were also associated with higher language levels and mainstreaming at younger ages. Higher ISP scores were associated with better social skills. Conclusions Results strongly support a link between indexical and linguistic properties in perceptual analysis of speech. These two channels of information appear to be processed together in parallel by the auditory system and are inseparable in perception. Better speech performance, for both linguistic and indexical perception, is associated with younger age at implantation and use of more recent speech processor technology. Children with better speech perception demonstrated better spoken language, earlier academic mainstreaming, and placement in more typically-sized classrooms (i.e., >20 students). Well-developed social skills were more highly associated with the ability to discriminate the nuances of talker identity and emotion than with the ability to recognize words and sentences through listening. The extent to which early cochlear implantation enabled these early-implanted children to make use of both linguistic and indexical properties of speech influenced not only their development of spoken language, but also their ability to function successfully in a hearing world. PMID:23652814
Occupational safety measures and morbidity among welders in Vellore, Southern India
Alexander, Vijay; Zechariah, Pradeep; Nair, Suryanarayan Rajendran; Kattula, Deepthi
2016-01-01
Background Welders in the unorganized occupational sector in the economically developing world are exposed to respiratory, skin, eye, ear, and neurological problems exacerbated by non-usage of personal protective equipment (PPE). Objective To study the frequency of health problems and the usage of PPE among welders in unorganized welding units in Vellore, India. Methods A cross-sectional survey was conducted among 150 welders to determine the frequency of skin, ear, eye, and respiratory morbidity and the usage of PPE. A group of 150 non-welders were chosen for comparison. Results Significant differences in the frequency of skin burns, redness, hyper pigmentation, itching, eye injuries, and sensorineural deafness were observed among the welders and non-welders (P < 0.001). Hypertension was noted in 12.6% of the welders as compared to 0.7% among the non-welders. None of the welders used appropriate PPE. For welders, low educational attainment was associated with an increased risk of eye injury (P < 0.05, OR = 0.29). There was also a significant difference between sensorineural deafness and a welder having less than 10 years of welding work experience (P < 0.001, OR = 18.18) which could probably be accounted for by the healthy worker effect. Conclusion Welders in this sample experienced a significant skin, eye, and ear morbidity accentuated by the non-usage of PPE. All worked without formal training and were unaware of the safe working guidelines that exist, but are not implemented for the welders in India. PMID:27682579
Park, Soojin; Seok, Jin Kyung; Kwak, Jun Yup; Suh, Hwa-Jin; Kim, Young Mi; Boo, Yong Chool
2016-01-01
Epidemiological and experimental evidence support health risks associated with the exposure to airborne particulate matter with a diameter of <10 μM (PM10). PM10 stimulates the production of reactive oxygen species (ROS) and inflammatory mediators. Thus, we assumed that natural antioxidants might provide health benefits attenuating hazardous effects of PM10. In the present study, we examined the effects of pomegranate peel extract (PPE) on THP-1 monocytic cells exposed to PM10. PM10 induced cytotoxicity and the production of ROS. It also increased the expression and secretion of inflammatory cytokines, such as tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β), and monocyte chemoattractant protein-1 (MCP-1), and cell adhesion molecules, such as intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1). PPE at 10-100 μg mL(-1) attenuated the production of ROS and the expression of TNF-α, IL-1β, MCP-1, and ICAM-1, but not VCAM-1, in THP-1 cells stimulated by PM10 (100 μg mL(-1)). PPE also attenuated the adhesion of PM10-stimulated THP-1 cells to EA.hy926 endothelial cells. PPE constituents, punicalagin and ellagic acid, attenuated PM10-induced monocyte adhesion to endothelial cells, and punicalagin was less cytotoxic compared to ellagic acid. The present study suggests that PPE and punicalagin may be useful in alleviating inflammatory reactions due to particulate matter.
IL-23 Is Essential for the Development of Elastase-Induced Pulmonary Inflammation and Emphysema.
Fujii, Utako; Miyahara, Nobuaki; Taniguchi, Akihiko; Waseda, Koichi; Morichika, Daisuke; Kurimoto, Etsuko; Koga, Hikari; Kataoka, Mikio; Gelfand, Erwin W; Cua, Daniel J; Yoshimura, Akihiko; Tanimoto, Mitsune; Kanehiro, Arihiko
2016-11-01
We recently reported that IL-17A plays a critical role in the development of porcine pancreatic elastase (PPE)-induced emphysema. The proliferation of T-helper type 17 (Th17) cells was induced by IL-23. To determine the contribution of IL-23 to the development of pulmonary emphysema, a mouse model of PPE-induced emphysema was used in which responses of IL-23p19-deficient (IL-23 -/- ) and wild-type (WT) mice were compared. Intratracheal instillation of PPE induced emphysematous changes in the lungs and was associated with increased levels of IL-23 in lung homogenates. Compared with WT mice, IL-23 -/- mice developed significantly lower static compliance values and markedly reduced emphysematous changes on histological analyses after PPE instillation. These changes were associated with lower levels of IL-17A and fewer Th17 cells in the lung. The neutrophilia seen in bronchoalveolar lavage fluid of WT mice was attenuated in IL-23 -/- mice, and the reduction was associated with decreased levels of keratinocyte-derived cytokine and macrophage inflammatory protein-2 in bronchoalveolar lavage fluid. Treatment with anti-IL-23p40 monoclonal antibody significantly attenuated PPE-induced emphysematous changes in the lungs of WT mice. These data identify the important contributions of IL-23 to the development of elastase-induced pulmonary inflammation and emphysema, mediated through an IL-23/IL-17 pathway. Targeting IL-23 in emphysema is a potential therapeutic strategy for delaying disease progression.
NASA Astrophysics Data System (ADS)
Aying, K. P.; Otadoy, R. E.; Violanda, R.
2015-06-01
This study investigates on the sound pressure level (SPL) of insert-type earphones that are commonly used for music listening of the general populace. Measurements of SPL from earphones of different respondents were measured by plugging the earphone to a physical ear canal model. Durations of the earphone used for music listening were also gathered through short interviews. Results show that 21% of the respondents exceed the standard loudness/duration relation recommended by the World Health Organization (WHO).
Jing, Linjing; Chen, Li; Peng, Haitao; Ji, Mizhi; Xiong, Yi; Lv, Guoyu
2017-12-01
Owing to the good degradability and biocompatibility of polyphosphoesters (PPEs), the aim of the current study was to investigate a novel degradable composite of nano-hydroxyapatite/poly(amino acid) (n-HA/PAA) with cyclophosphate (CPE) via in situ melting polymerization to improve the degradation of n-HA/PAA. The structure of each composite was characterized via Fourier transform infrared spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. The degradation properties were studied in terms of the weight loss and pH in a phosphate-buffered saline (PBS) solution, while the surface morphology was examined using a scanning electron microscope-energy dispersive spectrometer (SEM-EDS) after soaking the surface in simulated body fluid (SBF). The cell proliferation, cell adhesion, and alkaline phosphatase (ALP) activity were used for the analysis of cytocompatibility. The weight loss results showed that the n-HA/PAA composite was 9.98 wt%, weighed after soaking in the PBS solution for 12 weeks, whereas the nano-hydroxyapatite/polyphosphoester-amino acid (n-HA/PPE-AA) composite was 46.94 wt%. The pH of the composites was in a suitable range between 6.64 to 7.06 and finally stabilized at 7.39. The SEM and EDS results revealed the formation of an apatite-like layer on the surface of the n-HA/PPE-AA composites after soaking in SBF for one week. The cell counting Kit 8 (CCK-8) assay of the cell culture in the leaching liquid of the n-HA/PPE-AA composites exhibited non-cytotoxicity and high-proliferation, and the cell adhesion showed the well spreading and normal phenotype extension of the cells on the n-HA/PPE-AA composites surface. Concurrently, the co-culture results of the composites and cells confirmed that the n-HA/PPE-AA composites exhibited a higher ALP activity. In summary, the results demonstrated that the n-HA/PPE-AA composites had a controllable degradation property, good bioactivity, and cytocompatibility.
Free energy of mixing of acetone and methanol: a computer simulation investigation.
Idrissi, Abdenacer; Polok, Kamil; Barj, Mohammed; Marekha, Bogdan; Kiselev, Mikhail; Jedlovszky, Pál
2013-12-19
The change of the Helmholtz free energy, internal energy, and entropy accompanying the mixing of acetone and methanol is calculated in the entire composition range by the method of thermodynamic integration using three different potential model combinations of the two compounds. In the first system, both molecules are described by the OPLS, and in the second system, both molecules are described by the original TraPPE force field, whereas in the third system a modified version of the TraPPE potential is used for acetone in combination with the original TraPPE model of methanol. The results reveal that, in contrast with the acetone-water system, all of these three model combinations are able to reproduce the full miscibility of acetone and methanol, although the thermodynamic driving force of this mixing is very small. It is also seen, in accordance with the finding of former structural analyses, that the mixing of the two components is driven by the entropy term corresponding to the ideal mixing, which is large enough to overcompensate the effect of the energy increase and entropy loss due to the interaction of the unlike components in the mixtures. Among the three model combinations, the use of the original TraPPE model of methanol and modified TraPPE model of acetone turns out to be clearly the best in this respect, as it is able to reproduce the experimental free energy, internal energy, and entropy of mixing values within 0.15 kJ/mol, 0.2 kJ/mol, and 1 J/(mol K), respectively, in the entire composition range. The success of this model combination originates from the fact that the use of the modified TraPPE model of acetone instead of the original one in these mixtures improves the reproduction of the entropy of mixing, while it retains the ability of the original model of excellently reproducing the internal energy of mixing.
Keer, Sam; McLean, Dave; Glass, Bill; Douwes, Jeroen
2018-03-12
To assess the association between the use of personal protective equipment (PPE) and good workplace hygiene and symptoms of neurotoxicity in solvent-exposed vehicle spray painters. Exposure control measures including PPE-use and workplace hygiene practices and symptoms of neurotoxicity were assessed in 267 vehicle repair spray painters. Symptoms were assessed using an adapted version of the EUROQUEST Questionnaire. Frequent respirator and glove use was inversely and significantly associated with symptoms of neurotoxicity in a dose-dependent manner (P < 0.05 for trend) with the strongest protective effect found for consistent glove use (odds ratios [OR] 0.1-0.2, P < 0.01, for reporting ≥10 and ≥5 symptoms). A clear dose-response trend was also observed when combining frequency of respirator and glove use (P < 0.05 for reporting ≥5 and ≥10 symptoms), with an overall reduction in risk of 90% (OR, 0.1, P < 0.01) for those who consistently used both types of PPE. Protective effects were most pronounced for the symptom domains of psychosomatic (P < 0.05 for trend, for combined PPE use), mood (P < 0.05), and memory and concentration symptoms combined (P < 0.05), with reductions in risk of >80%. Poor hygiene workplace practices, such as solvent exposure to multiple body parts (OR 3.4, P = 0.11 for reporting ≥10 symptoms), were associated with an increased risk of symptoms. When using a general workplace hygiene score derived from a combination of PPE-use and (good) workplace practice factors an inverse and significant dose-response trend was observed for reporting ≥5 (P < 0.01) and ≥10 symptoms (P < 0.01). This study has shown that PPE-use and good workplace hygiene are associated with a strongly reduced risk of symptoms of neurotoxicity in solvent-exposed vehicle spray painters.
Bhogale, Sneha; Mahajan, Ameya S.; Natarajan, Bhavani; Rajabhoj, Mohit; Thulasiram, Hirekodathakallu V.; Banerjee, Anjan K.
2014-01-01
MicroRNA156 (miR156) functions in maintaining the juvenile phase in plants. However, the mobility of this microRNA has not been demonstrated. So far, only three microRNAs, miR399, miR395, and miR172, have been shown to be mobile. We demonstrate here that miR156 is a potential graft-transmissible signal that affects plant architecture and tuberization in potato (Solanum tuberosum). Under tuber-noninductive (long-day) conditions, miR156 shows higher abundance in leaves and stems, whereas an increase in abundance of miR156 has been observed in stolons under tuber-inductive (short-day) conditions, indicative of a photoperiodic control. Detection of miR156 in phloem cells of wild-type plants and mobility assays in heterografts suggest that miR156 is a graft-transmissible signal. This movement was correlated with changes in leaf morphology and longer trichomes in leaves. Overexpression of miR156 in potato caused a drastic phenotype resulting in altered plant architecture and reduced tuber yield. miR156 overexpression plants also exhibited altered levels of cytokinin and strigolactone along with increased levels of LONELY GUY1 and StCyclin D3.1 transcripts as compared with wild-type plants. RNA ligase-mediated rapid amplification of complementary DNA ends analysis validated SQUAMOSA PROMOTER BINDING-LIKE3 (StSPL3), StSPL6, StSPL9, StSPL13, and StLIGULELESS1 as targets of miR156. Gel-shift assays indicate the regulation of miR172 by miR156 through StSPL9. miR156-resistant SPL9 overexpression lines exhibited increased miR172 levels under a short-day photoperiod, supporting miR172 regulation via the miR156-SPL9 module. Overall, our results strongly suggest that miR156 is a phloem-mobile signal regulating potato development. PMID:24351688
Anomalous Annealing of a High-Resistivity CCD Irradiated at Low Temperature
NASA Astrophysics Data System (ADS)
Bautz, M.; Prigozhin, G.; Kissel, S.; LaMarr, B.; Grant, C.; Brown, S.
2005-04-01
The front-illuminated charge-coupled device (CCD) detectors in the Chandra X-ray Observatory's ACIS instrument suffered radiation damage from soft protons focused by the telescope mirror early in the mission. In the course of assessing this damage, the focal plane was temporarily warmed from its normal operating temperature (then -100/spl deg/C) to +30/spl deg/C. Following this "bakeout", the radiation-damaged CCDs exhibited significantly greater charge transfer inefficiency (CTI). We performed a laboratory experiment with a sibling of the flight detectors in an attempt to reproduce and better understand this phenomenon. The test CCD was cooled to -100/spl deg/C, irradiated by 120 keV protons and then warmed to +30/spl deg/C for 8 hours. As expected, after the initial irradiation, but before detector warmup, a substantial CTI increase was observed. The subsequent warmup itself then produced an additional factor /spl ap/2.5 increase in CTI. Following smaller subsequent irradiations with the detector cold, a "bakeout" for 8 hours at -60/spl deg/C produced no observable increase in CTI. However, a subsequent bakeout to +30/spl deg/C for another 8 hours resulted in an additional increase in CTI of roughly 15%. The CTI changes produced by the room temperature bakeout are accompanied by dramatic changes in the de-trapping times of electron traps responsible for the CTI. The distributions of signal amplitudes in the pixels trailing X-ray events indicate that annealing at room temperature can cause large changes of the trap emission times, from which we infer that conversion of trapping defects takes place. The observed phenomena can be explained by the previously suggested mechanism of carbon-related defect transformation. Specifically, the room-temperature annealing may allow carbon interstitials to form metastable complexes with phosphorus and/or carbon substitutional atoms.
ERIC Educational Resources Information Center
Smits, Pernelle A.; Champagne, Francois; Farand, Lambert
2012-01-01
The evaluation of interventions is becoming increasing common and now often seeks to involve managers in the process. Such practical participatory evaluation (PPE) aims to increase the use of evaluation results through the participation of stakeholders. This study focuses on the propensity of health managers for PPE, as measured through the…
ERIC Educational Resources Information Center
Wharton, Tracy; Alexander, Neil
2013-01-01
This article describes lessons learned about implementing evaluations in hospital settings. In order to overcome the methodological dilemmas inherent in this environment, we used a practical participatory evaluation (P-PE) strategy to engage as many stakeholders as possible in the process of evaluating a clinical demonstration project.…
ERIC Educational Resources Information Center
Bobadoye, Sunday A.; Afolami, Adewale J.; Olabode, Ogunmakinde; Aribisala, Emmanuel E.
2013-01-01
This study examined the link between the Nigeria Institute of Architects and the Architects Registration Council of Nigeria (ARCON) with respect to the Professional Practice Examinations (PPE). It sought to establish why so many graduates are yet to write the PPE and to identify the perceptions about the examination and the professional…
STS-42 Phase Partitioning Experiment (PPE) closeup taken onboard OV-103
NASA Technical Reports Server (NTRS)
1992-01-01
STS-42 Phase Partitioning Experiment (PPE), an International Microgravity Laboratory 1 (IML-1) experiment, is documented in a closeup taken onboard Discovery, Orbiter Vehicle (OV) 103. Phase partitioning is a very effective technique used by biochemists and cell biologists to obtain fairly pure cells. Cells are separated and collected in a mixture of two immiscible liquids (fluids that tend not to mix) by their surface characteristics. In the PPE, investigators feel they will be able to separate closely related cells because cell density and convection flows are not factors in the phase partitioning process in space. They also hope to study other factors that influence the process. Phase partitioning is used to separate biological materials such as bone marrow cells for cancer treatment.
Liu, Jinling; Park, Chan Ho; He, Feng; Nagano, Minoru; Wang, Mo; Bellizzi, Maria; Zhang, Kai; Zeng, Xiaoshan; Liu, Wende; Ning, Yuese; Kawano, Yoji; Wang, Guo-Liang
2015-01-01
The ubiquitin proteasome system in plants plays important roles in plant-microbe interactions and in immune responses to pathogens. We previously demonstrated that the rice U-box E3 ligase SPL11 and its Arabidopsis ortholog PUB13 negatively regulate programmed cell death (PCD) and defense response. However, the components involved in the SPL11/PUB13-mediated PCD and immune signaling pathway remain unknown. In this study, we report that SPL11-interacting Protein 6 (SPIN6) is a Rho GTPase-activating protein (RhoGAP) that interacts with SPL11 in vitro and in vivo. SPL11 ubiquitinates SPIN6 in vitro and degrades SPIN6 in vivo via the 26S proteasome-dependent pathway. Both RNAi silencing in transgenic rice and knockout of Spin6 in a T-DNA insertion mutant lead to PCD and increased resistance to the rice blast pathogen Magnaporthe oryzae and the bacterial blight pathogen Xanthomonas oryzae pv. oryzae. The levels of reactive oxygen species and defense-related gene expression are significantly elevated in both the Spin6 RNAi and mutant plants. Strikingly, SPIN6 interacts with the small GTPase OsRac1, catalyze the GTP-bound OsRac1 into the GDP-bound state in vitro and has GAP activity towards OsRac1 in rice cells. Together, our results demonstrate that the RhoGAP SPIN6 acts as a linkage between a U-box E3 ligase-mediated ubiquitination pathway and a small GTPase-associated defensome system for plant immunity. PMID:25658451
Research Opportunities at Storm Peak Laboratory
NASA Astrophysics Data System (ADS)
Hallar, A. G.; McCubbin, I. B.
2006-12-01
The Desert Research Institute (DRI) operates a high elevation facility, Storm Peak Laboratory (SPL), located on the west summit of Mt. Werner in the Park Range near Steamboat Springs, Colorado at an elevation of 3210 m MSL (Borys and Wetzel, 1997). SPL provides an ideal location for long-term research on the interactions of atmospheric aerosol and gas- phase chemistry with cloud and natural radiation environments. The ridge-top location produces almost daily transition from free tropospheric to boundary layer air which occurs near midday in both summer and winter seasons. Long-term observations at SPL document the role of orographically induced mixing and convection on vertical pollutant transport and dispersion. During winter, SPL is above cloud base 25% of the time, providing a unique capability for studying aerosol-cloud interactions (Borys and Wetzel, 1997). A comprehensive set of continuous aerosol measurements was initiated at SPL in 2002. SPL includes an office-type laboratory room for computer and instrumentation setup with outside air ports and cable access to the roof deck, a cold room for precipitation and cloud rime ice sample handling and ice crystal microphotography, a 150 m2 roof deck area for outside sampling equipment, a full kitchen and two bunk rooms with sleeping space for nine persons. The laboratory is currently well equipped for aerosol and cloud measurements. Particles are sampled from an insulated, 15 cm diameter manifold within approximately 1 m of its horizontal entry point through an outside wall. The 4 m high vertical section outside the building is capped with an inverted can to exclude large particles.
Interaction between Two Timing MicroRNAs Controls Trichome Distribution in Arabidopsis
Xue, Xue-Yi; Zhao, Bo; Chao, Lu-Men; Chen, Dian-Yang; Cui, Wen-Rui; Mao, Ying-Bo; Wang, Ling-Jian; Chen, Xiao-Ya
2014-01-01
The miR156-targeted SQUAMOSA PROMOTER BINDING PROTEIN LIKE (SPL) transcription factors function as an endogenous age cue in regulating plant phase transition and phase-dependent morphogenesis, but the control of SPL output remains poorly understood. In Arabidopsis thaliana the spatial pattern of trichome is a hallmark of phase transition and governed by SPLs. Here, by dissecting the regulatory network controlling trichome formation on stem, we show that the miR171-targeted LOST MERISTEMS 1 (LOM1), LOM2 and LOM3, encoding GRAS family members previously known to maintain meristem cell polarity, are involved in regulating the SPL activity. Reduced LOM abundance by overexpression of miR171 led to decreased trichome density on stems and floral organs, and conversely, constitutive expression of the miR171-resistant LOM (rLOM) genes promoted trichome production, indicating that LOMs enhance trichome initiation at reproductive stage. Genetic analysis demonstrated LOMs shaping trichome distribution is dependent on SPLs, which positively regulate trichome repressor genes TRICHOMELESS 1 (TCL1) and TRIPTYCHON (TRY). Physical interaction between the N-terminus of LOMs and SPLs underpins the repression of SPL activity. Importantly, other growth and developmental events, such as flowering, are also modulated by LOM-SPL interaction, indicating a broad effect of the LOM-SPL interplay. Furthermore, we provide evidence that MIR171 gene expression is regulated by its targeted LOMs, forming a homeostatic feedback loop. Our data uncover an antagonistic interplay between the two timing miRNAs in controlling plant growth, phase transition and morphogenesis through direct interaction of their targets. PMID:24699192
Freitas, Aline Silva; Fontes Cunha, Isabela Martinez; Andrade-Vieira, Larissa Fonseca; Techio, Vânia Helena
2016-02-01
Spent Pot Liner (SPL) is a solid waste from the aluminum industry frequently disposed of in industrial landfills; it can be leached and contaminate the soil, sources of drinking water and plantations, and thus may pose a risk to human health and to ecosystems. Its composition is high variable, including cyanide, fluoride and aluminum salts, which are highly toxic and environmental pollutants. This study evaluated the effect of SPL and its main components on root growth and the mitosis of Lactuca sativa, by investigating the mechanisms of cellular and chromosomal alterations with the aid of immunolocalization. To this end, newly emerged roots of L. sativa were exposed to SPL and its main components (solutions of cyanide, fluoride and aluminum) and to calcium chloride (control) for 48h. After this, root length was measured and cell cycle was examined by means of conventional cytogenetics and immunolocalization. Root growth was inhibited in the treatments with SPL and aluminum; chromosomal and nuclear alterations were observed in all treatments. The immunolocalization evidenced normal dividing cells with regular temporal and spatial distribution of histone H3 phosphorylation at serine 10 (H3S10ph). However, SPL and its main components inhibited the phosphorylation of histone H3 at serine 10, inactivated pericentromeric regions and affected the cohesion of sister chromatids, thus affecting the arrangement of chromosomes in the metaphase plate and separation of chromatids in anaphase. In addition, these substances induced breaks in pericentromeric regions, characterized as fragile sites. Copyright © 2015 Elsevier Inc. All rights reserved.
Wang, Jiaojian; Yang, Yong; Fan, Lingzhong; Xu, Jinping; Li, Changhai; Liu, Yong; Fox, Peter T; Eickhoff, Simon B; Yu, Chunshui; Jiang, Tianzi
2015-01-01
The superior parietal lobule (SPL) plays a pivotal role in many cognitive, perceptive, and motor-related processes. This implies that a mosaic of distinct functional and structural subregions may exist in this area. Recent studies have demonstrated that the ongoing spontaneous fluctuations in the brain at rest are highly structured and, like coactivation patterns, reflect the integration of cortical locations into long-distance networks. This suggests that the internal differentiation of a complex brain region may be revealed by interaction patterns that are reflected in different neuroimaging modalities. On the basis of this perspective, we aimed to identify a convergent functional organization of the SPL using multimodal neuroimaging approaches. The SPL was first parcellated based on its structural connections as well as on its resting-state connectivity and coactivation patterns. Then, post hoc functional characterizations and connectivity analyses were performed for each subregion. The three types of connectivity-based parcellations consistently identified five subregions in the SPL of each hemisphere. The two anterior subregions were found to be primarily involved in action processes and in visually guided visuomotor functions, whereas the three posterior subregions were primarily associated with visual perception, spatial cognition, reasoning, working memory, and attention. This parcellation scheme for the SPL was further supported by revealing distinct connectivity patterns for each subregion in all the used modalities. These results thus indicate a convergent functional architecture of the SPL that can be revealed based on different types of connectivity and is reflected by different functions and interactions. © 2014 Wiley Periodicals, Inc.
Storm Peak Laboratory 5th-6th Grade Climate and Weather Program
NASA Astrophysics Data System (ADS)
McCubbin, I. B.; Hallar, A. G.
2008-12-01
Storm Peak Laboratory (SPL) has created a place-based elementary school program, which has been implemented at five elementary schools in Northwest Colorado. Real understanding, not factual recall, is the primary goal and developing a desire to be lifelong learners in science is a secondary goal. The specific objectives of the program include the following: 1) Develop a weather and climate curriculum that teaches skills required by Colorado Student Assessment Program (CSAP). 2) Provide a hands-on place-based educational experience where students have an opportunity to use scientific equipment. 3) Provide students a three-day program that consists of an introduction, field program, and follow-up to help students grasp concepts and apply them to other school studies. 4) Provide all participating students with understanding of climate and weather 5) Build foundations for students to understand climate change. 6) Disseminate to alpine regions across the Western US, potentially impacting thousands of students that will experience the impacts of climate change during their lifetime. The SPL program spans three days for each school and includes five elementary schools. During the first day, a scientist and educators from SPL visit each classroom for two hours to introduce the concepts of climate and weather as well as teach students how to use scientific equipment. During the field program on the second day, students measure and record information about temperature, pressure, relative humidity, wind speed, and particle concentration while they travel to SPL via the gondola and chair lifts (in winter) or 4WD Suburbans (in fall). Once at the laboratory, students will meet with both SPL scientists and educators to tour the facility, discuss SPL research activities, and explore application of these activities to their curriculum. An alternative winter snowshoe program at the top of the gondola is offered to students who do not ski, where students have a program on snow science. At the end of the day each student has a data sheet with measurements recorded from 5 locations of different elevations to take back to the classroom. Following the field trip, SPL scientists and educators visit the school for a follow-up to help children grasp concepts, represent their data set collected in graphical formats, answer questions, and evaluate students" learning. Currently, approximately 250 students annually participate in the SPL 5th and 6th grade climate education program.
Recovery of Neonatal Head Turning to Decreased Sound Pressure Level.
ERIC Educational Resources Information Center
Tarquinio, Nancy; And Others
1990-01-01
Investigated newborns' responses to decreased sound pressure level (SPL) by means of a localized head turning habituation procedure. Findings, which demonstrated recovery of neonatal head turning to decreased SPL, were inconsistent with the selective receptor adaptation model. (RH)
Combining Static Model Checking with Dynamic Enforcement Using the Statecall Policy Language
NASA Astrophysics Data System (ADS)
Madhavapeddy, Anil
Internet protocols encapsulate a significant amount of state, making implementing the host software complex. In this paper, we define the Statecall Policy Language (SPL) which provides a usable middle ground between ad-hoc coding and formal reasoning. It enables programmers to embed automata in their code which can be statically model-checked using SPIN and dynamically enforced. The performance overheads are minimal, and the automata also provide higher-level debugging capabilities. We also describe some practical uses of SPL by describing the automata used in an SSH server written entirely in OCaml/SPL.
Contralateral ear occlusion for improving the reliability of otoacoustic emission screening tests.
Papsin, Emily; Harrison, Adrienne L; Carraro, Mattia; Harrison, Robert V
2014-01-01
Newborn hearing screening is an established healthcare standard in many countries and testing is feasible using otoacoustic emission (OAE) recording. It is well documented that OAEs can be suppressed by acoustic stimulation of the ear contralateral to the test ear. In clinical otoacoustic emission testing carried out in a sound attenuating booth, ambient noise levels are low such that the efferent system is not activated. However in newborn hearing screening, OAEs are often recorded in hospital or clinic environments, where ambient noise levels can be 60-70 dB SPL. Thus, results in the test ear can be influenced by ambient noise stimulating the opposite ear. Surprisingly, in hearing screening protocols there are no recommendations for avoiding contralateral suppression, that is, protecting the opposite ear from noise by blocking the ear canal. In the present study we have compared transient evoked and distortion product OAEs measured with and without contralateral ear plugging, in environmental settings with ambient noise levels <25 dB SPL, 45 dB SPL, and 55 dB SPL. We found out that without contralateral ear occlusion, ambient noise levels above 55 dB SPL can significantly attenuate OAE signals. We strongly suggest contralateral ear occlusion in OAE based hearing screening in noisy environments.
Functional Heterogeneity in Posterior Parietal Cortex Across Attention and Episodic Memory Retrieval
Hutchinson, J. Benjamin; Uncapher, Melina R.; Weiner, Kevin S.; Bressler, David W.; Silver, Michael A.; Preston, Alison R.; Wagner, Anthony D.
2014-01-01
While attention is critical for event memory, debate has arisen regarding the extent to which posterior parietal cortex (PPC) activation during episodic retrieval reflects engagement of PPC-mediated mechanisms of attention. Here, we directly examined the relationship between attention and memory, within and across subjects, using functional magnetic resonance imaging attention-mapping and episodic retrieval paradigms. During retrieval, 4 functionally dissociable PPC regions were identified. Specifically, 2 PPC regions positively tracked retrieval outcomes: lateral intraparietal sulcus (latIPS) indexed graded item memory strength, whereas angular gyrus (AnG) tracked recollection. By contrast, 2 other PPC regions demonstrated nonmonotonic relationships with retrieval: superior parietal lobule (SPL) tracked retrieval reaction time, consistent with a graded engagement of top-down attention, whereas temporoparietal junction displayed a complex pattern of below-baseline retrieval activity, perhaps reflecting disengagement of bottom-up attention. Analyses of retrieval effects in PPC topographic spatial attention maps (IPS0-IPS5; SPL1) revealed that IPS5 and SPL1 exhibited a nonmonotonic relationship with retrieval outcomes resembling that in the SPL region, further suggesting that SPL activation during retrieval reflects top-down attention. While demands on PPC attention mechanisms vary during retrieval attempts, the present functional parcellation of PPC indicates that 2 additional mechanisms (mediated by latIPS and AnG) positively track retrieval outcomes. PMID:23019246
Sasaki, S
1999-10-01
Functional connections of single reticulospinal neurons (RSNs) in the nucleus reticularis gigantocellularis (NRG) with ipsilateral dorsal neck motoneurons were examined with the spike-triggered averaging technique. Extracellular spikes of single NRG-RSNs activated antidromically from the C6, but not from the L1 segment (C-RSNs) were used as the trigger. These neurons were monosynaptically activated from the superior colliculus and the cerebral peduncle. Single-RSN PSPs were recorded in 43 dorsal neck motoneurons [biventer cervicis and complexus (BCC) and splenius (SPL)] for 21 NRG-RSNs and 135 motoneurons tested. All synaptic potentials were EPSPs, and most of their latencies, measured from the triggering spikes, were 0.8-1.5 ms, which is in a monosynaptic range. The amplitudes of single-RSN EPSPs were 10-360 microV. Spike-triggered averaging revealed single-RSN EPSPs in multiple motoneurons of the same species (SPL or BCC), their locations extending up to nearly 1 mm rostrocaudally. Synaptic connections of single RSNs with both SPL and BCC motoneurons were also found with some predominance for one of them. The results provide direct evidence that NRG-RSNs make monosynaptic excitatory connections with SPL and BCC motoneurons. It appears that some NRG-RSNs connect predominantly with SPL motoneurons and others with BCC motoneurons.
Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech.
Švec, Jan G; Granqvist, Svante
2018-03-15
Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
Advanced electric-field scanning probe lithography on molecular resist using active cantilever
NASA Astrophysics Data System (ADS)
Kaestner, Marcus; Aydogan, Cemal; Ivanov, Tzvetan; Ahmad, Ahmad; Angelov, Tihomir; Reum, Alexander; Ishchuk, Valentyn; Krivoshapkina, Yana; Hofer, Manuel; Lenk, Steve; Atanasov, Ivaylo; Holz, Mathias; Rangelow, Ivo W.
2015-07-01
The routine "on demand" fabrication of features smaller than 10 nm opens up new possibilities for the realization of many devices. Driven by the thermally actuated piezoresistive cantilever technology, we have developed a prototype of a scanning probe lithography (SPL) platform which is able to image, inspect, align, and pattern features down to the single digit nanoregime. Here, we present examples of practical applications of the previously published electric-field based current-controlled scanning probe lithography. In particular, individual patterning tests are carried out on calixarene by using our developed table-top SPL system. We have demonstrated the application of a step-and-repeat SPL method including optical as well as atomic force microscopy-based navigation and alignment. The closed-loop lithography scheme was applied to sequentially write positive and negative tone features. Due to the integrated unique combination of read-write cycling, each single feature is aligned separately with the highest precision and inspected after patterning. This routine was applied to create a pattern step by step. Finally, we have demonstrated the patterning over larger areas, over existing topography, and the practical applicability of the SPL processes for lithography down to 13-nm pitch patterns. To enhance the throughput capability variable beam diameter electric field, current-controlled SPL is briefly discussed.
Wearn, Andy; Bhoopatkar, Harsh
2006-10-01
Early clinical skills teaching often requires students to learn through examining one another. This model should acknowledge ethical, practical and individual issues, disclosure and identification of abnormalities. Consent to peer physical examination (PPE) is usually expected rather than discussed and sought. We sought to evaluate a formal written consent process for PPE and to explore students' views of this approach. A survey tool was designed and distributed to all years 2 and 3 students in the Auckland University medical programme (2004). Results were analysed using univariate statistics and thematic analysis. The response rate was 57% (146/258). Most students had read the participant information sheet prior to signing, with 78% giving consent. They had not felt coerced and the in-course experience matched the 'promise'. Comments included: PPE gave insights into the 'patient's world', encouraged peer learning and raised some professional issues. More than 95% of students took the examination role at least once (less likely if female, P = 0.002). Some European, Maori and Pacific students never took the role; all Asian students did at least once. Students preferred PPE in groups consisting of 'friends'. The task influenced group composition by sex (P < 0.0001) but not ethnicity. Students accept and support a formal consent process. PPE participation rates are similar to predictions. The experience must match the promises made. Formal preparation alone might have produced similar student outcomes. Female students are more selective about tasks undertaken. The influence of ethnicity and the effect on future behaviour and attitudes needs further exploration.
Prevalence of Cardiovascular Disorders Among Iranian Elite Athletes.
Salehi, Shahin; Moradi Shahpar, Farhad; Norouzi, Gholamreza; Ghazalian, Farshad; Poursaid Esfehani, Mehrshad; Abedi Yekta, Amir Hosein
2016-06-01
Athletes' health is an important issue and for promoting it, pre-participation examination (PPE) is widely performed by responsible bodies around the world. This study was to determine prevalence of cardiovascular disorders among athletes participating in the Asian games and answering the question whether the electrocardiogram (ECG) is a necessary part of pre-participation examination (PPE) for prevention of sudden cardiac death. All athletes participated at Asian games came to sports medicine federation for a PPE including a comprehensive questionnaire, physical examination and ECG. In this retrospective study all profiles of 338 athletes have been studied as well as their electrocardiograms. Multiple logistic regressions as well as Firth's bias reduction were used with R statistical software and SPSS. For predicting the changes in ECG, receiver operating characteristic (ROC) curve has done. Among 388 athletes, 80 (20.6%) were female and 308 (79.4%) male with mean age of 23.2 + 8 years. Nine athletes (2.3%) were smokers, 28 of them (7.2%) experienced chest pain and discomfort, 45 of them (13.3%) had palpitations and 28 (7.2%) had history of anemia. Study of their electrocardiograms showed that long Q-T interval was not seen for anyone, but evidence of left ventricular hypertrophy was seen in 12 (3.1%), inverted T wave in 6 (1.5%), and right bundle branch block in 45 (13.3%). PPE provides very important information of athletes' health. This study has shown that there was not any significant relation between current examination and electrocardiogram changes but regarding the ECG changes we recommend it as a routine part of PPE.
Park, Soojin; Seok, Jin Kyung; Kwak, Jun Yup; Suh, Hwa-Jin; Kim, Young Mi; Boo, Yong Chool
2016-01-01
Epidemiological and experimental evidence support health risks associated with the exposure to airborne particulate matter with a diameter of <10 μM (PM10). PM10 stimulates the production of reactive oxygen species (ROS) and inflammatory mediators. Thus, we assumed that natural antioxidants might provide health benefits attenuating hazardous effects of PM10. In the present study, we examined the effects of pomegranate peel extract (PPE) on THP-1 monocytic cells exposed to PM10. PM10 induced cytotoxicity and the production of ROS. It also increased the expression and secretion of inflammatory cytokines, such as tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β), and monocyte chemoattractant protein-1 (MCP-1), and cell adhesion molecules, such as intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1). PPE at 10–100 μg mL−1 attenuated the production of ROS and the expression of TNF-α, IL-1β, MCP-1, and ICAM-1, but not VCAM-1, in THP-1 cells stimulated by PM10 (100 μg mL−1). PPE also attenuated the adhesion of PM10-stimulated THP-1 cells to EA.hy926 endothelial cells. PPE constituents, punicalagin and ellagic acid, attenuated PM10-induced monocyte adhesion to endothelial cells, and punicalagin was less cytotoxic compared to ellagic acid. The present study suggests that PPE and punicalagin may be useful in alleviating inflammatory reactions due to particulate matter. PMID:27247608
Bruce-Low, S S; Cotterrell, D; Jones, G E
2007-01-15
Fire fighter breathing apparatus instructors (BAIs) must possess the ability to respond to both the extrinsic stress of a high temperature environment and the intrinsic stress from wearing personal protective equipment (PPE) and self-contained breathing apparatus (SCBA), repeatedly and regularly, whilst training recruits in live fire training exercises (LFTEs). There are few previous investigations on BAIs in hot environments such as LFTEs, since the main research focus has been on regular fire fighters undertaking exercises in temperate or fire conditions at a moderate to high exercise intensity. In this study, the intrinsic cardiovascular stress effects of wearing PPE + SCBA were first investigated using a step test whilst wearing gym kit (control), weighted gym kit (a rucksack weighted to the equivalent of PPE + SCBA) and full PPE + SCBA (weight plus the effects of protective clothing). The extrinsic effects of the very hot environment were investigated in BIAs in LFTEs compared to mock fire training exercises (MFTEs), where the fire was not ignited. There was an increase in heart rate due to the modest workload imposed on the BAIs through carrying out the MFTEs (25.0 (18.7)%) compared to resting. However, when exposed to fire during the LFTEs, heat storage appears to be significant as the heart rate increased by up to 39.8 (+/-20.1)% over that of the mock LFTEs at temperate conditions. Thus, being able to dissipate heat from the PPE is particularly important in reducing the cardiovascular responses for BAIs during LFTEs.
Fletcher, Tom E; Gulzhan, Abuova; Ahmeti, Salih; Al-Abri, Seif S; Asik, Zahide; Atilla, Aynur; Beeching, Nick J; Bilek, Heval; Bozkurt, Ilkay; Christova, Iva; Duygu, Fazilet; Esen, Saban; Khanna, Arjun; Kader, Çiğdem; Mardani, Masoud; Mahmood, Faisal; Mamuchishvili, Nana; Pshenichnaya, Natalia; Sunbul, Mustafa; Yalcin, Tuğba Y; Leblebicioglu, Hakan
2017-01-01
Crimean Congo Hemorrhagic Fever (CCHF) is a life threatening acute viral infection that presents significant risk of nosocomial transmission to healthcare workers. Evaluation of CCHF infection prevention and control (IP&C) practices in healthcare facilities that routinely manage CCHF cases in Eurasia. A cross-sectional CCHF IP&C survey was designed and distributed to CCHF centers in 10 endemic Eurasian countries in 2016. Twenty-three responses were received from centers in Turkey, Pakistan, Russia, Georgia, Kosovo, Bulgaria, Oman, Iran, India and Kazakhstan. All units had dedicated isolation rooms for CCHF, with cohorting of confirmed cases in 15/23 centers and cohorting of suspect and confirmed cases in 9/23 centers. There was adequate personal protective equipment (PPE) in 22/23 facilities, with 21/23 facilities reporting routine use of PPE for CCHF patients. Adequate staffing levels to provide care reported in 14/23 locations. All centers reported having a high risk CCHFV nosocomial exposure in last five years, with 5 centers reporting more than 5 exposures. Education was provided annually in most centers (13/23), with additional training requested in PPE use (11/23), PPE donning/doffing (12/23), environmental disinfection (12/23) and waste management (14/23). Staff and patient safety must be improved and healthcare associated CCHF exposure and transmission eliminated. Improvements are recommended in isolation capacity in healthcare facilities, use of PPE and maintenance of adequate staffing levels. We recommend further audit of IP&C practice at individual units in endemic areas, as part of national quality assurance programs.
Gulzhan, Abuova; Ahmeti, Salih; Al-Abri, Seif S.; Asik, Zahide; Atilla, Aynur; Beeching, Nick J.; Bilek, Heval; Bozkurt, Ilkay; Christova, Iva; Duygu, Fazilet; Esen, Saban; Khanna, Arjun; Kader, Çiğdem; Mardani, Masoud; Mahmood, Faisal; Mamuchishvili, Nana; Pshenichnaya, Natalia; Sunbul, Mustafa; Yalcin, Tuğba Y.; Leblebicioglu, Hakan
2017-01-01
Background Crimean Congo Hemorrhagic Fever (CCHF) is a life threatening acute viral infection that presents significant risk of nosocomial transmission to healthcare workers. Aim Evaluation of CCHF infection prevention and control (IP&C) practices in healthcare facilities that routinely manage CCHF cases in Eurasia. Methods A cross-sectional CCHF IP&C survey was designed and distributed to CCHF centers in 10 endemic Eurasian countries in 2016. Results Twenty-three responses were received from centers in Turkey, Pakistan, Russia, Georgia, Kosovo, Bulgaria, Oman, Iran, India and Kazakhstan. All units had dedicated isolation rooms for CCHF, with cohorting of confirmed cases in 15/23 centers and cohorting of suspect and confirmed cases in 9/23 centers. There was adequate personal protective equipment (PPE) in 22/23 facilities, with 21/23 facilities reporting routine use of PPE for CCHF patients. Adequate staffing levels to provide care reported in 14/23 locations. All centers reported having a high risk CCHFV nosocomial exposure in last five years, with 5 centers reporting more than 5 exposures. Education was provided annually in most centers (13/23), with additional training requested in PPE use (11/23), PPE donning/doffing (12/23), environmental disinfection (12/23) and waste management (14/23). Conclusions Staff and patient safety must be improved and healthcare associated CCHF exposure and transmission eliminated. Improvements are recommended in isolation capacity in healthcare facilities, use of PPE and maintenance of adequate staffing levels. We recommend further audit of IP&C practice at individual units in endemic areas, as part of national quality assurance programs. PMID:28886039
Usubuchi, Hajime; Vetter, Douglas E.; Elgoyhen, A. Bélen; Thomas, Steven A.; Liberman, M. Charles
2012-01-01
Suppression of ipsilateral distortion product otoacoustic emissions (DPOAEs) by contralateral noise is used in humans and animals to assay the strength of sound-evoked negative feedback from the medial olivocochlear (MOC) efferent pathway. However, depending on species and anesthesia, contributions of other feedback systems to the middle or inner ear can cloud the interpretation. Here, contributions of MOC and middle-ear muscle reflexes, as well as autonomic feedback, to contra-noise suppression in anesthetized mice are dissected by selectively eliminating each pathway by surgical transection, pharmacological blockade, or targeted gene deletion. When ipsilateral DPOAEs were evoked by low-level primaries, contra-noise suppression was typically ∼1 dB with contra-noise levels around 95 dB SPL, and it always disappeared upon contralateral cochlear destruction. Lack of middle-ear muscle contribution was suggested by persistence of contra-noise suppression after paralysis with curare, tensor tympani cauterization, or section of the facial nerve. Contribution of cochlear sympathetics was ruled out by studying mutant mice lacking adrenergic signaling (dopamine β-hydroxylase knockouts). Surprisingly, contra-noise effects on low-level DPOAEs were also not diminished by eliminating the MOC system pharmacologically (strychnine), surgically, or by deletion of relevant cholinergic receptors (α9/α10). In contrast, when ipsilateral DPOAEs were evoked by high-level primaries, the contra-noise suppression, although comparable in magnitude, was largely eliminated by MOC blockade or section. Possible alternate pathways are discussed for the source of contra-noise-evoked effects at low ipsilateral levels. PMID:22514298
Dhar, Sumitrajit; Shaffer, Lauren A
2004-12-01
The use of a suppressor tone has been proposed as the method of choice in obtaining single-generator distortion product (DP) grams, the speculation being that such DP grams will be more predictive of hearing thresholds. Current distortion product otoacoustic emissions (DPOAE) theory points to the ear canal DPOAE signal being a complex interaction between multiple components. The effectiveness of a suppressor tone is predicted to be dependent entirely on the relative levels of these components. We examine the validity of using a suppressor tone through a detailed examination of the effects of a suppressor on DPOAE fine structure in individual ears. DPOAE fine structure, recorded in 10 normal-hearing individuals with a suppressor tone at 45, 55, and 65 dB SPL, was compared with recordings without a suppressor. Behavioral hearing thresholds were also measured in the same subjects, using 2-dB steps. The effect of the suppressor tone on DPOAE fine structure varied between ears and was dependent on frequency within ears. Correlation between hearing thresholds and DPOAE level measured without a suppressor was similar to previous reports. The effects of the suppressor are explained in the theoretical framework of a model involving multiple DPOAE components. Our results suggest that a suppressor tone can have highly variable effects on fine structure across individuals or even across frequency within one ear, thereby making the use of a suppressor less viable as a clinical tool for obtaining single-generator DP grams.
Moore, Brian C J
2012-09-01
This article reviews a series of studies on the factors influencing sound quality preferences, mostly for jazz and classical music stimuli. The data were obtained using ratings of individual stimuli or using the method of paired comparisons. For normal-hearing participants, the highest ratings of sound quality were obtained when the reproduction bandwidth was wide (55 to 16000 Hz) and ripples in the frequency response were small (less than ± 5 dB). For hearing-impaired participants listening via a simulated five-channel compression hearing aid with gains set using the CAM2 fitting method, preferences for upper cutoff frequency varied across participants: Some preferred a 7.5- or 10-kHz upper cutoff frequency over a 5-kHz cutoff frequency, and some showed the opposite preference. Preferences for a higher upper cutoff frequency were associated with a shallow high-frequency slope of the audiogram. A subsequent study comparing the CAM2 and NAL-NL2 fitting methods, with gains slightly reduced for participants who were not experienced hearing aid users, showed a consistent preference for CAM2. Since the two methods differ mainly in the gain applied for frequencies above 4 kHz (CAM2 recommending higher gain than NAL-NL2), these results suggest that extending the upper cutoff frequency is beneficial. A system for reducing "overshoot" effects produced by compression gave small but significant benefits for sound quality of a percussion instrument (xylophone). For a high-input level (80 dB SPL), slow compression was preferred over fast compression.
Personal protective equipment and risk for avian influenza (H7N3).
Morgan, Oliver; Kuhne, Mirjam; Nair, Pat; Verlander, Neville Q; Preece, Richard; McDougal, Marianne; Zambon, Maria; Reacher, Mark
2009-01-01
An outbreak of avian influenza (H7N3) among poultry resulted in laboratory-confirmed disease in 1 of 103 exposed persons. Incomplete use of personal protective equipment (PPE) was associated with conjunctivitis and influenza-like symptoms. Rigorous use of PPE by persons managing avian influenza outbreaks may reduce exposure to potentially hazardous infected poultry materials.
Personal Protective Equipment and Risk for Avian Influenza (H7N3)
Kuhne, Mirjam; Nair, Pat; Verlander, Neville Q.; Preece, Richard; McDougal, Marianne; Zambon, Maria; Reacher, Mark
2009-01-01
An outbreak of avian influenza (H7N3) among poultry resulted in laboratory-confirmed disease in 1 of 103 exposed persons. Incomplete use of personal protective equipment (PPE) was associated with conjunctivitis and influenza-like symptoms. Rigorous use of PPE by persons managing avian influenza outbreaks may reduce exposure to potentially hazardous infected poultry materials. PMID:19116052
Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 CP810 Sound Processor.
Dillier, Norbert; Lai, Wai Kong
2015-06-11
The Nucleus(®) 5 System Sound Processor (CP810, Cochlear™, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom™ Sound Processor (Cochlear™) for speech in quiet and noise for a subset of the processing options. This study compares the two processing options suggested to be used in noisy environments, Zoom and Beam, for various sound field conditions using a standardized speech in noise matrix test (Oldenburg sentences test). Nine German-speaking subjects who previously had been using the Freedom speech processor and subsequently were upgraded to the CP810 device participated in this series of additional evaluation tests. The speech reception threshold (SRT for 50% speech intelligibility in noise) was determined using sentences presented via loudspeaker at 65 dB SPL in front of the listener and noise presented either via the same loudspeaker (S0N0) or at 90 degrees at either the ear with the sound processor (S0NCI+) or the opposite unaided ear (S0NCI-). The fourth noise condition consisted of three uncorrelated noise sources placed at 90, 180 and 270 degrees. The noise level was adjusted through an adaptive procedure to yield a signal to noise ratio where 50% of the words in the sentences were correctly understood. In spatially separated speech and noise conditions both Zoom and Beam could improve the SRT significantly. For single noise sources, either ipsilateral or contralateral to the cochlear implant sound processor, average improvements with Beam of 12.9 and 7.9 dB in SRT were found. The average SRT of -8 dB for Beam in the diffuse noise condition (uncorrelated noise from both sides and back) is truly remarkable and comparable to the performance of normal hearing listeners in the same test environment. The static directivity (Zoom) option in the diffuse noise condition still provides a significant benefit of 5.9 dB in comparison with the standard omnidirectional microphone setting. These results indicate that CI recipients may improve their speech recognition in noisy environments significantly using these directional microphone-processing options.
Ip, Philip P C; Irving, Julie A; McCluggage, W Glenn; Clement, Philip B; Young, Robert H
2013-02-01
Papillary proliferation of the endometrium (PPE) without cytologic atypia is uncommon and has only been studied in detail by Lehman and Hart in 2001. On histologic examination, PPE ranges from simple papillae with fibrovascular cores, often involving the surface of endometrial polyps, to complex intracystic proliferations; some consider the latter to be analogous to nonatypical complex hyperplasia. To further characterize PPE, with emphasis on the risk of and features associated with concurrent or subsequent neoplasia, the clinicopathologic features of 59 cases without cytologic atypia were studied. The cases were classified into 2 groups according to the degree of architectural complexity and extent of proliferation. Group 1 consisted of those with localized simple papillae. Simple papillae were defined as those with short, predominantly nonbranching stalks; those with occasional secondary branches and/or detached papillae were also included in this group. Localized proliferations were those with 1 or 2 foci involving the surface or the subjacent glands of polyps or nonpolypoid endometrium. Group 2 consisted of those with complex papillae and/or those with diffuse and crowded intracystic papillae. Complex papillae were those with either short or long stalks, with frequent secondary and complex branches. Diffuse proliferation was defined as presence of 3 or more foci within a specimen or involvement of >50% of the endometrial polyp by simple or complex PPE. Any coexistent or subsequent hyperplasia of conventional type (World Health Organization classification) or adenocarcinoma was recorded. The age of patients ranged from 23 to 82 years (median, 53 y); 36 (61%) were postmenopausal. The majority presented with abnormal vaginal bleeding. Sixteen patients (27%) were receiving hormonal preparations including 5 who were treated with a progestogen for preexisting endometrial hyperplasia or low-grade endometrioid adenocarcinoma. The histologic diagnosis of PPE was made in 49 biopsies and in 10 hysterectomy specimens. Thirty-six cases (61%) were classified as group 1 and 23 (39%) as group 2. In 47 cases (80%), there was a coexisting endometrial polyp, 39 (66%) of which were involved by the PPE. Fifty-three cases (90%) had coexisting epithelial metaplastic changes, 41 (77%) of which were involved by the PPE. The most common type of metaplasia was mucinous (41 of 59 cases, or 69%). Follow-up information was known for 46 patients (78%). Coexistent or subsequent nonatypical and atypical hyperplasia was found in 8 (17%) and 6 cases (13%), respectively. In 6 of the 46 cases (13%), a low-grade endometrioid adenocarcinoma was present either in the original specimen or during follow-up. In contrast to group 1 PPE, those with group 2 features were significantly associated with concurrent or subsequent premalignant lesions (nonatypical and atypical hyperplasia) or carcinoma (P<0.0001). This study indicates that localized and architecturally simple PPEs confined to a completely removed polyp are usually associated with a benign outcome and may be appropriately labeled as "benign papillary proliferation of the endometrium." Lesions with architecturally complex papillae, especially when extensive, have an increased risk of concurrent or subsequent endometrial hyperplasia and carcinoma and should probably be regarded as analogous to atypical complex hyperplasia, and the term "complex papillary hyperplasia" is appropriate. As the distinction between simple and complex PPE may be difficult in small endometrial aspirational samples, consideration for curettage should be given to ascertain whether the lesion has been completely removed.
Balser, Nils; Lorey, Britta; Pilgramm, Sebastian; Naumann, Tim; Kindermann, Stefan; Stark, Rudolf; Zentgraf, Karen; Williams, A Mark; Munzert, Jörn
2014-01-01
In many daily activities, and especially in sport, it is necessary to predict the effects of others' actions in order to initiate appropriate responses. Recently, researchers have suggested that the action-observation network (AON) including the cerebellum plays an essential role during such anticipation, particularly in sport expert performers. In the present study, we examined the influence of task-specific expertise on the AON by investigating differences between two expert groups trained in different sports while anticipating action effects. Altogether, 15 tennis and 16 volleyball experts anticipated the direction of observed tennis and volleyball serves while undergoing functional magnetic resonance imaging (fMRI). The expert group in each sport acted as novice controls in the other sport with which they had only little experience. When contrasting anticipation in both expertise conditions with the corresponding untrained sport, a stronger activation of AON areas (SPL, SMA), and particularly of cerebellar structures, was observed. Furthermore, the neural activation within the cerebellum and the SPL was linearly correlated with participant's anticipation performance, irrespective of the specific expertise. For the SPL, this relationship also holds when an expert performs a domain-specific anticipation task. Notably, the stronger activation of the cerebellum as well as of the SMA and the SPL in the expertise conditions suggests that experts rely on their more fine-tuned perceptual-motor representations that have improved during years of training when anticipating the effects of others' actions in their preferred sport. The association of activation within the SPL and the cerebellum with the task achievement suggests that these areas are the predominant brain sites involved in fast motor predictions. The SPL reflects the processing of domain-specific contextual information and the cerebellum the usage of a predictive internal model to solve the anticipation task.