Sample records for db standard deviation

  1. Analysis of in-flight acoustic data for a twin-engined turboprop airplane

    NASA Technical Reports Server (NTRS)

    Wilby, J. F.; Wilby, E. G.

    1988-01-01

    Acoustic measurements were made on the exterior and interior of a general aviation turboprop airplane during four flight tests. The test conditions were carefully controlled and repeated for each flight in order to determine data variability. For the first three flights the cabin was untreated and for the fourth flight the fuselage was treated with glass fiber batts. On the exterior, measured propeller harmonic sound pressure levels showed typical standard deviations of +1.4 dB, -2.3 dB, and turbulent boundary layer pressure levels, +1.2 dB, -1.6. Propeller harmonic levels in the cabin showed greater variability, with typical standard deviations of +2.0 dB, -4.2 dB. When interior sound pressure levels from different flights with different cabin treatments were used to evaluate insertion loss, the standard deviations were typically plus or minus 6.5 dB. This is due in part to the variability of the sound pressure level measurements, but probably is also influenced by changes in the model characteristics of the cabin. Recommendations are made for the planning and performance of future flight tests to measure interior noise of propeller-driven aircraft, either high-speed advanced turboprop or general aviation propellers.

  2. A complex symbol signal-to-noise ratio estimator and its performance

    NASA Technical Reports Server (NTRS)

    Feria, Y.

    1994-01-01

    This article presents an algorithm for estimating the signal-to-noise ratio (SNR) of signals that contain data on a downconverted suppressed carrier or the first harmonic of a square-wave subcarrier. This algorithm can be used to determine the performance of the full-spectrum combiner for the Galileo S-band (2.2- to 2.3-GHz) mission by measuring the input and output symbol SNR. A performance analysis of the algorithm shows that the estimator can estimate the complex symbol SNR using 10,000 symbols at a true symbol SNR of -5 dB with a mean of -4.9985 dB and a standard deviation of 0.2454 dB, and these analytical results are checked by simulations of 100 runs with a mean of -5.06 dB and a standard deviation of 0.2506 dB.

  3. The Standard Deviation of Launch Vehicle Environments

    NASA Technical Reports Server (NTRS)

    Yunis, Isam

    2005-01-01

    Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.

  4. Measurements of propeller noise in a light turboprop airplane

    NASA Technical Reports Server (NTRS)

    Wilby, J. F.; Wilby, E. G.

    1987-01-01

    In-flight acoustic measurements have been made on the exterior and interior of a twin-engined turboprop airplane under controlled conditions to study data repeatability. It is found that the variability of the harmonic sound pressure levels in the cabin is greater than that for the exterior sound pressure levels, typical values for the standard deviation being +2.0 dB and -4.2 dB for the interior, versus +1.4 dB and -2.3 dB for the exterior. When insertion losses are determined for acoustic treatments in the cabin, the standard deviations of the data are typically + or - 6.5 dB. It is concluded that additional factors, such as accurate and repeatable selection of relative phase between propellers, controlled cabin-air-temperatures, installation of baseline acoustic absorption, and measurement of aircraft attitude, should be considered in order to reduce uncertainty in the measured data.

  5. Propeller aircraft interior noise model. II - Scale-model and flight-test comparisons

    NASA Technical Reports Server (NTRS)

    Willis, C. M.; Mayes, W. H.

    1987-01-01

    A program for predicting the sound levels inside propeller driven aircraft arising from sidewall transmission of airborne exterior noise is validated through comparisons of predictions with both scale-model test results and measurements obtained in flight tests on a turboprop aircraft. The program produced unbiased predictions for the case of the scale-model tests, with a standard deviation of errors of about 4 dB. For the case of the flight tests, the predictions revealed a bias of 2.62-4.28 dB (depending upon whether or not the data for the fourth harmonic were included) and the standard deviation of the errors ranged between 2.43 and 4.12 dB. The analytical model is shown to be capable of taking changes in the flight environment into account.

  6. S-193 scatterometer backscattering cross section precision/accuracy for Skylab 2 and 3 missions

    NASA Technical Reports Server (NTRS)

    Krishen, K.; Pounds, D. J.

    1975-01-01

    Procedures for measuring the precision and accuracy with which the S-193 scatterometer measured the background cross section of ground scenes are described. Homogeneous ground sites were selected, and data from Skylab missions were analyzed. The precision was expressed as the standard deviation of the scatterometer-acquired backscattering cross section. In special cases, inference of the precision of measurement was made by considering the total range from the maximum to minimum of the backscatter measurements within a data segment, rather than the standard deviation. For Skylab 2 and 3 missions a precision better than 1.5 dB is indicated. This procedure indicates an accuracy of better than 3 dB for the Skylab 2 and 3 missions. The estimates of precision and accuracy given in this report are for backscattering cross sections from -28 to 18 dB. Outside this range the precision and accuracy decrease significantly.

  7. Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar

    PubMed Central

    Gabella, Marco; Leuenberger, Andreas

    2017-01-01

    The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of −0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the “small” (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB. PMID:28531164

  8. Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar.

    PubMed

    Gabella, Marco; Leuenberger, Andreas

    2017-05-22

    The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of -0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the "small" (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB.

  9. Visual field changes after cataract extraction: the AGIS experience.

    PubMed

    Koucheki, Behrooz; Nouri-Mahdavi, Kouros; Patel, Gitane; Gaasterland, Douglas; Caprioli, Joseph

    2004-12-01

    To test the hypothesis that cataract extraction in glaucomatous eyes improves overall sensitivity of visual function without affecting the size or depth of glaucomatous scotomas. Experimental study with no control group. One hundred fifty-eight eyes (of 140 patients) from the Advanced Glaucoma Intervention Study with at least two reliable visual fields within a year both before and after cataract surgery were included. Average mean deviation (MD), pattern standard deviation (PSD), and corrected pattern standard deviation (CPSD) were compared before and after cataract extraction. To evaluate changes in scotoma size, the number of abnormal points (P < .05) on the pattern deviation plot was compared before and after surgery. We described an index ("scotoma depth index") to investigate changes of scotoma depth after surgery. Mean values for MD, PSD, and CPSD were -13.2, 6.4, and 5.9 dB before and -11.9, 6.8, and 6.2 dB after cataract surgery (P < or = .001 for all comparisons). Mean (+/- SD) number of abnormal points on pattern deviation plot was 26.7 +/- 9.4 and 27.5 +/- 9.0 before and after cataract surgery, respectively (P = .02). Scotoma depth index did not change after cataract extraction (-19.3 vs -19.2 dB, P = .90). Cataract extraction caused generalized improvement of the visual field, which was most marked in eyes with less advanced glaucomatous damage. Although the enlargement of scotomas was statistically significant, it was not clinically meaningful. No improvement of sensitivity was observed in the deepest part of the scotomas.

  10. Slant path L- and S-Band tree shadowing measurements

    NASA Technical Reports Server (NTRS)

    Vogel, Wolfhard J.; Torrence, Geoffrey W.

    1994-01-01

    This contribution presents selected results from simultaneous L- and S-Band slant-path fade measurements through a pecan, a cottonwood, and a pine tree employing a tower-mounted transmitter and dual-frequency receiver. A single, circularly-polarized antenna was used at each end of the link. The objective was to provide information for personal communications satellite design on the correlation of tree shadowing between frequencies near 1620 and 2500 MHz. Fades were measured along 10 m lateral distance with 5 cm spacing. Instantaneous fade differences between L- and S-Band exhibited normal distribution with means usually near 0 dB and standard deviations from 5.2 to 7.5 dB. The cottonwood tree was an exception, with 5.4 dB higher average fading at S- than at L-Band. The spatial autocorrelation reduced to near zero with lags of about 10 lambda. The fade slope in dB/MHz is normally distributed with zero mean and standard deviation increasing with fade level.

  11. Slant path L- and S-Band tree shadowing measurements

    NASA Astrophysics Data System (ADS)

    Vogel, Wolfhard J.; Torrence, Geoffrey W.

    1994-08-01

    This contribution presents selected results from simultaneous L- and S-Band slant-path fade measurements through a pecan, a cottonwood, and a pine tree employing a tower-mounted transmitter and dual-frequency receiver. A single, circularly-polarized antenna was used at each end of the link. The objective was to provide information for personal communications satellite design on the correlation of tree shadowing between frequencies near 1620 and 2500 MHz. Fades were measured along 10 m lateral distance with 5 cm spacing. Instantaneous fade differences between L- and S-Band exhibited normal distribution with means usually near 0 dB and standard deviations from 5.2 to 7.5 dB. The cottonwood tree was an exception, with 5.4 dB higher average fading at S- than at L-Band. The spatial autocorrelation reduced to near zero with lags of about 10 lambda. The fade slope in dB/MHz is normally distributed with zero mean and standard deviation increasing with fade level.

  12. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as the experience of study participants and test administrators, and the fit-test psychometric tasks are suggested as possible contributors to the observed results. PMID:27786602

  13. Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects.

    PubMed

    Su, Daniel; Greenberg, Andrew; Simonson, Joseph L; Teng, Christopher C; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul

    2016-04-01

    To investigate the efficacy of the Amsler grid test in detecting central visual field (VF) defects in glaucoma. Prospective, cross-sectional study. Patients with glaucoma with reliable Humphrey 10-2 Swedish Interactive Threshold Algorithm standard VF on the date of enrollment or within the previous 3 months. Amsler grid tests were performed for each eye and were considered "abnormal" if there was any perceived scotoma with missing or blurry grid lines within the central 10 degrees ("Amsler grid scotoma"). An abnormal 10-2 VF was defined as ≥3 adjacent points at P < 0.01 with at least 1 point at P < 0.005 in the same hemifield on the pattern deviation plot. Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area were calculated with the 10-2 VF as the clinical reference standard. Among eyes with an abnormal 10-2 VF, regression analyses were performed between the Amsler grid scotoma area and the 10-2 VF parameters (mean deviation [MD], scotoma extent [number of test points with P < 0.01 in total deviation map] and scotoma mean depth [mean sensitivity of test points with P < 0.01 in total deviation map]). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area. A total of 106 eyes (53 patients) were included (mean ± standard deviation age, 24-2 MD and 10-2 MD = 66±12 years, -9.61±8.64 decibels [dB] and -9.75±9.00 dB, respectively). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid test were 68%, 92%, 97%, and 46%, respectively. Sensitivity was 40% in eyes with 10-2 MD better than -6 dB, 58% in eyes with 10-2 MD between -12 and -6 dB, and 92% in eyes with 10-2 MD worse than -12 dB. The area under the receiver operating characteristic curve of the Amsler grid scotoma area was 0.810 (95% confidence interval, 0.723-0.880, P < 0.001). The Amsler grid scotoma area had the strongest relationship with 10-2 MD (quadratic R(2)=0.681), followed by 10-2 scotoma extent (quadratic R(2)=0.611) and 10-2 scotoma mean depth (quadratic R(2)=0.299) (all P < 0.001). The Amsler grid can be used to screen for moderate to severe central vision loss from glaucoma. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Enhancing active and passive remote sensing in the ocean using broadband acoustic transmissions and coherent hydrophone arrays

    NASA Astrophysics Data System (ADS)

    Tran, Duong Duy

    The statistics of broadband acoustic signal transmissions in a random continental shelf waveguide are characterized for the fully saturated regime. The probability distribution of broadband signal energies after saturated multi-path propagation is derived using coherence theory. The frequency components obtained from Fourier decomposition of a broadband signal are each assumed to be fully saturated, where the energy spectral density obeys the exponential distribution with 5.6 dB standard deviation and unity scintillation index. When the signal bandwidth and measurement time are respectively larger than the correlation bandwidth and correlation time of its energy spectral density components, the broadband signal energy obtained by integrating the energy spectral density across the signal bandwidth then follows the Gamma distribution with standard deviation smaller than 5.6 dB and scintillation index less than unity. The theory is verified with broadband transmissions in the Gulf of Maine shallow water waveguide in the 300-1200 Hz frequency range. The standard deviations of received broadband signal energies range from 2.7 to 4.6 dB for effective bandwidths up to 42 Hz, while the standard deviations of individual energy spectral density components are roughly 5.6 dB. The energy spectral density correlation bandwidths of the received broadband signals are found to be larger for signals with higher center frequency. Sperm whales in the New England continental shelf and slope were passively localized, in both range and bearing using a single low-frequency (< 2500 Hz), densely sampled, towed horizontal coherent hydrophone array system. Whale bearings were estimated using time-domain beamforming that provided high coherent array gain in sperm whale click signal-to-noise ratio. Whale ranges from the receiver array center were estimated using the moving array triangulation technique from a sequence of whale bearing measurements. The dive profile was estimated for a sperm whale in the shallow waters of the Gulf of Maine with 160 m water-column depth, located close to the array's near-field where depth estimation was feasible by employing time difference of arrival of the direct and multiply reflected click signals received on the array. The dependence of broadband energy on bandwidth and measurement time was verified employing recorded sperm whale clicks in the Gulf of Maine.

  15. Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.

    PubMed

    Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-07-01

    To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no relationship between variability and sensitivity with FDT2 (P = 0.46). In comparison with SAP, FDT2 exhibited narrower test-retest intervals at test locations with lower sensitivity (SAP thresholds <25 dB). A comparison of the total and pattern deviation maps between both techniques showed that the total deviation analyses of FDT2 may slightly underestimate the visual field loss apparent with SAP. However, the pattern-deviation maps of both instruments agreed well with each other. The test-retest variability of FDT2 is uniform over the measurement range of the instrument. These properties may provide advantages for the monitoring of patients with glaucoma that should be investigated in longitudinal studies.

  16. The effects of auditory stimulation with music on heart rate variability in healthy women.

    PubMed

    Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de

    2013-07-01

    There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.

  17. The effects of auditory stimulation with music on heart rate variability in healthy women

    PubMed Central

    Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos

    2013-01-01

    OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660

  18. Self-test web-based pure-tone audiometry: validity evaluation and measurement error analysis.

    PubMed

    Masalski, Marcin; Kręcicki, Tomasz

    2013-04-12

    Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. The aim of this research was to determine the measurement error of the hearing threshold determined in the way described above and to identify and analyze factors influencing its value. The evaluation of the hearing threshold was made in three series: (1) tests on a clinical audiometer, (2) self-tests done on a specially calibrated computer under the supervision of an audiologist, and (3) self-tests conducted at home. The research was carried out on the group of 51 participants selected from patients of an audiology outpatient clinic. From the group of 51 patients examined in the first two series, the third series was self-administered at home by 37 subjects (73%). The average difference between the value of the hearing threshold determined in series 1 and in series 2 was -1.54dB with standard deviation of 7.88dB and a Pearson correlation coefficient of .90. Between the first and third series, these values were -1.35dB±10.66dB and .84, respectively. In series 3, the standard deviation was most influenced by the error connected with the procedure of hearing threshold identification (6.64dB), calibration error (6.19dB), and additionally at the frequency of 250Hz by frequency nonlinearity error (7.28dB). The obtained results confirm the possibility of applying Web-based pure-tone audiometry in screening tests. In the future, modifications of the method leading to the decrease in measurement error can broaden the scope of Web-based pure-tone audiometry application.

  19. Do you hear the noise? The German matrix sentence test with a fixed noise level in subjects with normal hearing and hearing impairment.

    PubMed

    Wardenga, Nina; Batsoulis, Cornelia; Wagener, Kirsten C; Brand, Thomas; Lenarz, Thomas; Maier, Hannes

    2015-01-01

    The aim of this study was to determine the relationship between hearing loss and speech reception threshold (SRT) in a fixed noise condition using the German Oldenburg sentence test (OLSA). After training with two easily-audible lists of the OLSA, SRTs were determined monaurally with headphones at a fixed noise level of 65 dB SPL using a standard adaptive procedure, converging to 50% speech intelligibility. Data was obtained from 315 ears of 177 subjects with hearing losses ranging from -5 to 90 dB HL pure-tone average (PTA, 0.5, 1, 2, 3 kHz). Two domains were identified with a linear dependence of SRT on PTA. The SRT increased with a slope of 0.094 ± 0.006 dB SNR/dB HL (standard deviation (SD) of residuals = 1.17 dB) for PTAs < 47 dB HL and with a slope of 0.811 ± 0.049 dB SNR/dB HL (SD of residuals = 5.54 dB) for higher PTAs. The OLSA can be applied to subjects with a wide range of hearing losses. With 65 dB SPL fixed noise presentation level the SRT is determined by listening in noise for PTAs < ∼47 dB HL, and above it is determined by listening in quiet.

  20. A nonrandomized comparison of the thulium laser and the CO2 laser in primary stapedotomy for otosclerosis.

    PubMed

    Kamalski, Digna M A; Vincent, Robert; Wegner, Inge; Bittermann, Arnold J N; Grolman, Wilko

    2014-12-01

    Comparing hearing results in patients with otosclerosis treated with laser-assisted stapedotomy using the 2-μm thulium laser or the CO2 laser. Prospective nonrandomized clinical study. In a tertiary referral center in France (Jean Causse Ear Clinic, Béziers), 208 primary stapedotomies were performed in 204 patients between March 2008 and November 2009. Sufficient follow-up data were available for 194 procedures. The fenestration in the footplate was made with the thulium laser in 98 procedures and with a flexible CO2 laser in 96 procedures. Preoperative and postoperative audiometric results were compared. Side effects, such as vertigo and tinnitus, were scored. Patients treated with the CO2 laser had better hearing outcome compared with those treated with the thulium laser at both 3 and 12 months of follow-up. At 3 months, the success of the surgery, defined as closure of the air-bone gap to within 10 dB, was 90.0% in the thulium group compared with 96.8% in the CO2 group. Bone conduction shift showed an overall deterioration of 1.6 dB (standard deviation, 6.9 dB) in the thulium group compared with an improvement of 1.3 dB (standard deviation, 4 dB) in the CO2 group. In the thulium group, there were four patients with sensorineural hearing loss (4.4%) and three with tinnitus (3.1%) compared with none in the CO2 group. Stapedotomy surgery performed with a fiber-delivered thulium laser resulted in a higher chance of inner ear damage measured by bone conduction shift compared with the use of a fiber-delivered CO2 laser. We advise not to use the thulium laser for stapedotomy.

  1. Effects of blur and repeated testing on sensitivity estimates with frequency doubling perimetry.

    PubMed

    Artes, Paul H; Nicolela, Marcelo T; McCormick, Terry A; LeBlanc, Raymond P; Chauhan, Balwantray C

    2003-02-01

    To investigate the effect of blur and repeated testing on sensitivity with frequency doubling technology (FDT) perimetry. One eye of 12 patients with glaucoma (mean deviation [MD] mean, -2.5 dB, range +0.5 to -4.3 dB) and 11 normal control subjects underwent six consecutive tests with the FDT N30 threshold program in each of two sessions. In session 1, blur was induced by trial lenses (-6.00, -3.00, 0.00, +3.00, and +6.00 D, in random order). In session 2, only the effects of repeated testing were evaluated. The MD and pattern standard deviation (PSD) indices were evaluated as functions of blur and of test order. By correcting the data of session 1 for the reduction of sensitivity with repeated testing (session 2), the effect of blur on FDT sensitivities was established, and its clinical consequences evaluated on total- and pattern-deviation probability maps. FDT sensitivities decreased with blur (by <0.5 dB/D) and with repeated testing (by approximately 2 dB between the first and sixth tests). Blur and repeated testing independently led to larger numbers of locations with significant total and pattern deviation. Sensitivity reductions were similar in normal control subjects and patients with glaucoma, at central and peripheral test locations and at locations with high and low sensitivities. However, patients with glaucoma showed larger deterioration in the total-deviation-probability maps. To optimize the performance of the device, refractive errors should be corrected and immediate retesting avoided. Further research is needed to establish the cause of sensitivity loss with repeated FDT testing.

  2. Properties of pattern standard deviation in open-angle glaucoma patients with hemi-optic neuropathy and bi-optic neuropathy.

    PubMed

    Heo, Dong Won; Kim, Kyoung Nam; Lee, Min Woo; Lee, Sung Bok; Kim, Chang-Sik

    2017-01-01

    To evaluate the properties of pattern standard deviation (PSD) according to localization of the glaucomatous optic neuropathy. We enrolled 242 eyes of 242 patients with primary open-angle glaucoma, with a best-corrected visual acuity ≥ 20/25, and no media opacity. Patients were examined via dilated fundus photography, spectral-domain optical coherence tomography, and Humphrey visual field examination, and divided into those with hemi-optic neuropathy (superior or inferior) and bi-optic neuropathy (both superior and inferior). We assessed the relationship between mean deviation (MD) and PSD. Using broken stick regression analysis, the tipping point was identified, i.e., the point at which MD became significantly associated with a paradoxical reversal of PSD. In 91 patients with hemi-optic neuropathy, PSD showed a strong correlation with MD (r = -0.973, β = -0.965, p < 0.001). The difference between MD and PSD ("-MD-PSD") was constant (mean, -0.32 dB; 95% confidence interval, -2.48~1.84 dB) regardless of visual field defect severity. However, in 151 patients with bi-optic neuropathy, a negative correlation was evident between "-MD-PSD" and MD (r2 = 0.907, p < 0.001). Overall, the MD tipping point was -14.0 dB, which was close to approximately 50% damage of the entire visual field (p < 0.001). Although a false decrease of PSD usually begins at approximately 50% visual field damage, in patients with hemi-optic neuropathy, the PSD shows no paradoxical decrease and shows a linear correlation with MD.

  3. Multichannel silicon WDM ring filters fabricated with DUV lithography

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Moo; Park, Sahnggi; Kim, Gyungock

    2008-09-01

    We have fabricated 9-channel silicon wavelength-division-multiplexing (WDM) ring filters using 193 nm deep-ultraviolet (DUV) lithography and investigated the spectral properties of the ring filters by comparing the transmission spectra with and without an upper cladding. The average channel-spacing of the 9-channel WDM ring filter with a polymeric upper cladding is measured about 1.86 nm with the standard deviation of the channel-spacing about 0.34 nm. The channel crosstalk is about -30 dB, and the minimal drop loss is about 2 dB.

  4. Luminance sticker based facial expression recognition using discrete wavelet transform for physically disabled persons.

    PubMed

    Nagarajan, R; Hariharan, M; Satiyan, M

    2012-08-01

    Developing tools to assist physically disabled and immobilized people through facial expression is a challenging area of research and has attracted many researchers recently. In this paper, luminance stickers based facial expression recognition is proposed. Recognition of facial expression is carried out by employing Discrete Wavelet Transform (DWT) as a feature extraction method. Different wavelet families with their different orders (db1 to db20, Coif1 to Coif 5 and Sym2 to Sym8) are utilized to investigate their performance in recognizing facial expression and to evaluate their computational time. Standard deviation is computed for the coefficients of first level of wavelet decomposition for every order of wavelet family. This standard deviation is used to form a set of feature vectors for classification. In this study, conventional validation and cross validation are performed to evaluate the efficiency of the suggested feature vectors. Three different classifiers namely Artificial Neural Network (ANN), k-Nearest Neighborhood (kNN) and Linear Discriminant Analysis (LDA) are used to classify a set of eight facial expressions. The experimental results demonstrate that the proposed method gives very promising classification accuracies.

  5. Stapedotomy in osteogenesis imperfecta: a prospective study of 32 consecutive cases.

    PubMed

    Vincent, Robert; Wegner, Inge; Stegeman, Inge; Grolman, Wilko

    2014-12-01

    To prospectively evaluate hearing outcomes in patients with osteogenesis imperfecta undergoing primary stapes surgery and to isolate prognostic factors for success. A nonrandomized, open, prospective case series. A tertiary referral center. Twenty-five consecutive patients who underwent 32 primary stapedotomies for osteogenesis imperfecta with evidence of stapes fixation and available postoperative pure-tone audiometry. Primary stapedotomy with vein graft interposition and reconstruction with a regular Teflon piston or bucket handle-type piston. Preoperative and postoperative audiometric evaluation using conventional 4-frequency (0.5, 1, 2, and 4 kHz) audiometry. Air-conduction thresholds, bone-conduction thresholds, and air-bone gap were measured. The overall audiometric results as well as the results of audiometric evaluation at 3 months and at least 1 year after surgery were used. Overall, postoperative air-bone gap closure to within 10 dB was achieved in 88% of cases. Mean (standard deviation) gain in air-conduction threshold was 22 (9.4) dB for the entire case series, and mean (standard deviation) air-bone gap closure was 22 (9.0) dB. Backward multivariate logistic regression showed that a model with preoperative air-bone gap closure and intraoperatively established incus length accurately predicts success after primary stapes surgery. Stapes surgery is a feasible and safe treatment option in patients with osteogenesis imperfecta. Success is associated with preoperative air-bone gap and intraoperatively established incus length.

  6. Simultaneous measurements of L- and S-band tree shadowing for space-Earth communications

    NASA Technical Reports Server (NTRS)

    Vogel, Wolfhard J.; Torrence, Geoffrey W.; Lin, Hsin P.

    1995-01-01

    We present results from simultaneous L- and S-Band slant-path fade measurements through trees. One circularly-polarized antenna was used at each end of the dual-frequency link to provide information on the correlation of tree shadowing at 1620 and 2500 MHz. Fades were measured laterally in the shadow region with 5 cm spacing. Fade differences between L- and S-Band had a normal distribution with low means and standard deviations from 5.2 to 7.5 dB. Spatial variations occurred with periods larger than 1-2 wavelengths. Swept measurements over 160 MHz spans showed that the stdv. of power as function of frequency increased from approximately 1-6 dB at locations with mean fades of 4 and 20 dB, respectively. At a 5 dB fade, the central 90% of fade slopes were within a range of 0.7 (1.9) dB/MHz at L-(S-) Band.

  7. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    PubMed Central

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776

  8. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    PubMed

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  9. Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies.

    PubMed

    Artes, Paul H; Iwase, Aiko; Ohno, Yuko; Kitazawa, Yoshiaki; Chauhan, Balwantray C

    2002-08-01

    To investigate the distributions of threshold estimates with the Swedish Interactive Threshold Algorithms (SITA) Standard, SITA Fast, and the Full Threshold algorithm (Humphrey Field Analyzer; Zeiss-Humphrey Instruments, Dublin, CA) and to compare the pointwise test-retest variability of these strategies. One eye of 49 patients (mean age, 61.6 years; range, 22-81) with glaucoma (Mean Deviation mean, -7.13 dB; range, +1.8 to -23.9 dB) was examined four times with each of the three strategies. The mean and median SITA Standard and SITA Fast threshold estimates were compared with a "best available" estimate of sensitivity (mean results of three Full Threshold tests). Pointwise 90% retest limits (5th and 95th percentiles of retest thresholds) were derived to assess the reproducibility of individual threshold estimates. The differences between the threshold estimates of the SITA and Full Threshold strategies were largest ( approximately 3 dB) for midrange sensitivities ( approximately 15 dB). The threshold distributions of SITA were considerably different from those of the Full Threshold strategy. The differences remained of similar magnitude when the analysis was repeated on a subset of 20 locations that are examined early during the course of a Full Threshold examination. With sensitivities above 25 dB, both SITA strategies exhibited lower test-retest variability than the Full Threshold strategy. Below 25 dB, the retest intervals of SITA Standard were slightly smaller than those of the Full Threshold strategy, whereas those of SITA Fast were larger. SITA Standard may be superior to the Full Threshold strategy for monitoring patients with visual field loss. The greater test-retest variability of SITA Fast in areas of low sensitivity is likely to offset the benefit of even shorter test durations with this strategy. The sensitivity differences between the SITA and Full Threshold strategies may relate to factors other than reduced fatigue. They are, however, small in comparison to the test-retest variability.

  10. Comparison of mean deviation with AGIS and CIGTS scores in association with structural parameters in glaucomatous eyes.

    PubMed

    Naka, Maiko; Kanamori, Akiyasu; Tatsumi, Yasuko; Fujioka, Miyuki; Nagai-Kusuhara, Azusa; Nakamura, Makoto; Negi, Akira

    2009-01-01

    To evaluate which of the 3 clinically used visual field indices including mean deviation (MD), Advanced Glaucoma Intervention Study (AGIS) score, and Collaborative Initial Glaucoma Treatment Study (CIGTS) score are best in evaluating functional damage of glaucomatous optic neuropathy. In 213 glaucomatous eyes, peripapillary retinal nerve fiber layer thickness (RNFLT) and optic disc configuration were measured with Stratus optical coherence tomography and Heidelberg Retina Tomograph-2, respectively. Visual field was measured with standard automated perimetry 30-2. Correlations of the structural parameters compared with the 3 VF indices using second polynomial regression were calculated. In addition, these correlations were analyzed among eyes of 3 different stages of glaucoma, as defined by MD score (early, MD> or =-6 dB; moderate, -12 dB< or =MD<-6 dB; advanced, MD<-12 dB). Among structure-function relationships in all subjects, the highest correlation determination (R) was MD with RNFLT (=0.298). CIGTS score showed better R than MD or AGIS score with rim area, but these values were not higher than any R with RNFLT. In analyses of 3 groups depending on MD, statistically significant structure-function correlations were observed only in patients with an advanced stage. No clear difference was found among MD and AGIS/CIGTS scores in expressing functional damage of glaucomatous eyes. MD is suggested to be no worse than others in monitoring glaucoma in clinical setting.

  11. Relationship among visual field, blood flow, and neural structure measurements in glaucoma.

    PubMed

    Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David

    2012-05-17

    To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P < 0.001). Visual field loss was correlated with both reduced retinal blood flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.

  12. ATS-6 ascending: Near horizon measurements over water at 30 GHz

    NASA Technical Reports Server (NTRS)

    Vogel, W. J.; Straiton, A. W.; Fannin, B. M.

    1977-01-01

    The return of the ATS 6 satellite to a western longitude during the fall of 1976 presented a unique opportunity to perform low angle of elevation measurements at 30 GHz. For this purpose a receiver using a 1.5 m antenna was set up at Port Aransas, Texas, resulting in a propagation path entirely over water. The 30 GHz beacon was monitored daily for at least one hour from 8 September 1976 to 21 September 1976. During the time the elevation angle changed from 1.5 deg to 17.3 deg, the mean attenuation decreased from 20 dB to 2 dB and the standard deviation from over 6 dB to less than .2 dB. The deep fades at angles below 4 deg show significantly sharper nulls than peaks on a log scale. Spectra of the log amplitude fluctuations vary as the (-8/3) power of the spectral frequency in the limit. A flattening is noticeable at the low frequencies. A precipitation event at 8.5 deg elevation produced a 16 dB fade and significantly increased the variance.

  13. Behavior of visual field index in advanced glaucoma.

    PubMed

    Rao, Harsha L; Senthil, Sirisha; Choudhari, Nikhil S; Mandal, Anil K; Garudadri, Chandra S

    2013-01-14

    To evaluate the magnitude of Visual Field Index (VFI) change attributable to change in the estimation algorithm from the pattern deviation probability plot (PDPP) to the total deviation probability plot (TDPP) when the mean deviation (MD) crosses -20 decibels (dB). In a retrospective study, 37 stable glaucoma eyes in which MD of the VFs crossed -20 dB were identified. For each eye, a pair of VFs was selected so that one VF of the pair had a MD better than but close to -20 dB and the other had a MD worse than but again close to -20 dB. The change in VFI in the VF pairs and its associations with the number of points in probability plots with normal threshold sensitivities were evaluated. Similar pairs of VFs from 28 stable glaucoma eyes where the MD crossed -10 dB were chosen as controls. The change in VFI in VF pairs when the MD crossed 20 dB ranged from 3% to 33% (median: 15%), while the change when MD crossed -10 dB ranged from 1% to 8% (median: 4%). Difference in the number of points with normal threshold sensitivities in PDPP when MD was better than -20 dB compared to those in TDPP when MD crossed -20 dB significantly influenced the VFI change (R(2) = 0.65). Considering the eccentricity of these points further explained the VFI change (R(2) = 0.81). The decrease in VFI when MD crosses -20 dB can be highly variable. This has to be considered with the use of VFI in clinical and research settings.

  14. A-Weighted Sound Levels in Cockpits of Fixed- and Rotary-Wing Aircraft.

    DTIC Science & Technology

    fixed-wing vehicles and from 98 to 106 dB for helicopters. Means and standard deviations are reported by octave-bands, all-pass (flat), A - levels , and...preferred speech interference levels (PSIL, average of 500, 1000 and 2000 Hz). Also, at-the-ear A - levels are reported for generalized amounts of attenuation provided by headsets commonly worn in aircraft. (Author)

  15. Reduction in mean deviation values in automated perimetry in eyes with multifocal compared to monofocal intraocular lens implants.

    PubMed

    Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F

    2014-08-01

    To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    PubMed

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  17. Design and Evaluation of a Personal Diffusion Battery.

    PubMed

    Vosburgh, Donna J H; Klein, Timothy; Sheehan, Maura; Anthony, T Renee; Peters, Thomas M

    A four-stage personal diffusion battery (pDB) was designed and constructed to measure submicron particle size distributions. The pDB consisted of a screen-type diffusion battery, solenoid valve system, and electronic controller. A data inversion spreadsheet was created to solve for the number median diameter (NMD), geometric standard deviation (GSD), and particle number concentration of unimodal aerosols using stage number concentrations from the pDB combined with a handheld condensation particle counter (pDB+CPC). The inversion spreadsheet included particle entry losses, theoretical penetrations across screens, the detection efficiency of the CPC, and constraints so the spreadsheet solved to values within the pDB range. Size distribution parameters (NMD, GSD, and number concentration) measured with the pDB+CPC with inversion spreadsheet were within 25% of those measured with a scanning mobility particle sizer (SMPS) for 5 of 12 polydisperse combustion aerosols. For three tests conducted with propylene torch exhaust, the pDB+CPC with inversion spreadsheet successfully identified that the NMD was smaller than the constraint value of 16 nm. The ratio of the nanoparticle portion of the aerosol compared to the reference ( R nano ) was calculated to determine the ability of pDB+CPC with inversion spreadsheet to measure the nanoparticle portion of the aerosols. The R nano ranged from 0.87 to 1.01 when the inversion solved and from 0.06 to 2.01 when the inversion solved to a constraint. The pDB combined with CPC has limited use as a personal monitor but combining the pDB with a different detector would allow for the pDB to be used as a personal monitor.

  18. Design and Evaluation of a Personal Diffusion Battery

    PubMed Central

    Vosburgh, Donna J. H.; Klein, Timothy; Sheehan, Maura; Anthony, T. Renee; Peters, Thomas M.

    2016-01-01

    A four-stage personal diffusion battery (pDB) was designed and constructed to measure submicron particle size distributions. The pDB consisted of a screen-type diffusion battery, solenoid valve system, and electronic controller. A data inversion spreadsheet was created to solve for the number median diameter (NMD), geometric standard deviation (GSD), and particle number concentration of unimodal aerosols using stage number concentrations from the pDB combined with a handheld condensation particle counter (pDB+CPC). The inversion spreadsheet included particle entry losses, theoretical penetrations across screens, the detection efficiency of the CPC, and constraints so the spreadsheet solved to values within the pDB range. Size distribution parameters (NMD, GSD, and number concentration) measured with the pDB+CPC with inversion spreadsheet were within 25% of those measured with a scanning mobility particle sizer (SMPS) for 5 of 12 polydisperse combustion aerosols. For three tests conducted with propylene torch exhaust, the pDB+CPC with inversion spreadsheet successfully identified that the NMD was smaller than the constraint value of 16 nm. The ratio of the nanoparticle portion of the aerosol compared to the reference (R nano) was calculated to determine the ability of pDB+CPC with inversion spreadsheet to measure the nanoparticle portion of the aerosols. The R nano ranged from 0.87 to 1.01 when the inversion solved and from 0.06 to 2.01 when the inversion solved to a constraint. The pDB combined with CPC has limited use as a personal monitor but combining the pDB with a different detector would allow for the pDB to be used as a personal monitor. PMID:26900207

  19. Amplitude (vu and rms) and Temporal (msec) Measures of Two Northwestern University Auditory Test No. 6 Recordings.

    PubMed

    Wilson, Richard H

    2015-04-01

    In 1940, a cooperative effort by the radio networks and Bell Telephone produced the volume unit (vu) meter that has been the mainstay instrument for monitoring the level of speech signals in commercial broadcasting and research laboratories. With the use of computers, today the amplitude of signals can be quantified easily using the root mean square (rms) algorithm. Researchers had previously reported that amplitude estimates of sentences and running speech were 4.8 dB higher when measured with a vu meter than when calculated with rms. This study addresses the vu-rms relation as applied to the carrier phrase and target word paradigm used to assess word-recognition abilities, the premise being that by definition the word-recognition paradigm is a special and different case from that described previously. The purpose was to evaluate the vu and rms amplitude relations for the carrier phrases and target words commonly used to assess word-recognition abilities. In addition, the relations with the target words between rms level and recognition performance were examined. Descriptive and correlational. Two recoded versions of the Northwestern University Auditory Test No. 6 were evaluated, the Auditec of St. Louis (Auditec) male speaker and the Department of Veterans Affairs (VA) female speaker. Using both visual and auditory cues from a waveform editor, the temporal onsets and offsets were defined for each carrier phrase and each target word. The rms amplitudes for those segments then were computed and expressed in decibels with reference to the maximum digitization range. The data were maintained for each of the four Northwestern University Auditory Test No. 6 word lists. Descriptive analyses were used with linear regressions used to evaluate the reliability of the measurement technique and the relation between the rms levels of the target words and recognition performances. Although there was a 1.3 dB difference between the calibration tones, the mean levels of the carrier phrases for the two recordings were -14.8 dB (Auditec) and -14.1 dB (VA) with standard deviations <1 dB. For the target words, the mean amplitudes were -19.9 dB (Auditec) and -18.3 dB (VA) with standard deviations ranging from 1.3 to 2.4 dB. The mean durations for the carrier phrases of both recordings were 593-594 msec, with the mean durations of the target words a little different, 509 msec (Auditec) and 528 msec (VA). Random relations were observed between the recognition performances and rms levels of the target words. Amplitude and temporal data for the individual words are provided. The rms levels of the carrier phrases closely approximated (±1 dB) the rms levels of the calibration tones, both of which were set to 0 vu (dB). The rms levels of the target words were 5-6 dB below the levels of the carrier phrases and were substantially more variable than the levels of the carrier phrases. The relation between the rms levels of the target words and recognition performances on the words was random. American Academy of Audiology.

  20. A novel multiplexed fluorescence polarisation immunoassay based on a recombinant bi-specific single-chain diabody for simultaneous detection of fluoroquinolones and sulfonamides in milk.

    PubMed

    Chen, Min; Wen, Kai; Tao, Xiaoqi; Ding, Shuangyang; Xie, Jie; Yu, Xuezhi; Li, Jiancheng; Xia, Xi; Wang, Yang; Xie, Sanlei; Jiang, Haiyang

    2014-01-01

    Major research efforts are focusing on the development of simultaneous multiplexed immunoassays. In this study, a novel dual-binding fluorescence polarisation immunoassay (DB-FPIA) using a broad-specificity bi-specific single-chain diabody (scDb) and two fluorescent-labelled tracers (sulfamethoxypyridazine-fluorescein isothiocyanate (SMP-FITC) and sarafloxacin-Texas Red (SAR-TR)) with different excitation and emission wavelengths was developed for simultaneous and high-throughput detection of 19 fluoroquinolones (FQs) and 13 sulfonamides (SAs) at the maximum residue limits in milk samples. Recoveries for spiked milk samples were from 76.4% to 128.4%, with a relative standard deviation lower than 13.9%. The developed DB-FPIA was then applied to field samples, followed by confirmation by LC-MS/MS. All three instances in which FQs and SAs were present at concentrations near or above the assay limit of detection were identified as positive by the developed DB-FPIA, demonstrating that the method is suitable for rapid screening of FQs and SAs contamination. The novel methodology combines the advantage of the FPIA and the broad sensitivity of scDb and shows great promise for fast multi-analyte screening of low-molecular weight chemical residues in food samples.

  1. Experimental investigations on airborne gravimetry based on compressed sensing.

    PubMed

    Yang, Yapeng; Wu, Meiping; Wang, Jinling; Zhang, Kaidong; Cao, Juliang; Cai, Shaokun

    2014-03-18

    Gravity surveys are an important research topic in geophysics and geodynamics. This paper investigates a method for high accuracy large scale gravity anomaly data reconstruction. Based on the airborne gravimetry technology, a flight test was carried out in China with the strap-down airborne gravimeter (SGA-WZ) developed by the Laboratory of Inertial Technology of the National University of Defense Technology. Taking into account the sparsity of airborne gravimetry by the discrete Fourier transform (DFT), this paper proposes a method for gravity anomaly data reconstruction using the theory of compressed sensing (CS). The gravity anomaly data reconstruction is an ill-posed inverse problem, which can be transformed into a sparse optimization problem. This paper uses the zero-norm as the objective function and presents a greedy algorithm called Orthogonal Matching Pursuit (OMP) to solve the corresponding minimization problem. The test results have revealed that the compressed sampling rate is approximately 14%, the standard deviation of the reconstruction error by OMP is 0.03 mGal and the signal-to-noise ratio (SNR) is 56.48 dB. In contrast, the standard deviation of the reconstruction error by the existing nearest-interpolation method (NIPM) is 0.15 mGal and the SNR is 42.29 dB. These results have shown that the OMP algorithm can reconstruct the gravity anomaly data with higher accuracy and fewer measurements.

  2. Experimental Investigations on Airborne Gravimetry Based on Compressed Sensing

    PubMed Central

    Yang, Yapeng; Wu, Meiping; Wang, Jinling; Zhang, Kaidong; Cao, Juliang; Cai, Shaokun

    2014-01-01

    Gravity surveys are an important research topic in geophysics and geodynamics. This paper investigates a method for high accuracy large scale gravity anomaly data reconstruction. Based on the airborne gravimetry technology, a flight test was carried out in China with the strap-down airborne gravimeter (SGA-WZ) developed by the Laboratory of Inertial Technology of the National University of Defense Technology. Taking into account the sparsity of airborne gravimetry by the discrete Fourier transform (DFT), this paper proposes a method for gravity anomaly data reconstruction using the theory of compressed sensing (CS). The gravity anomaly data reconstruction is an ill-posed inverse problem, which can be transformed into a sparse optimization problem. This paper uses the zero-norm as the objective function and presents a greedy algorithm called Orthogonal Matching Pursuit (OMP) to solve the corresponding minimization problem. The test results have revealed that the compressed sampling rate is approximately 14%, the standard deviation of the reconstruction error by OMP is 0.03 mGal and the signal-to-noise ratio (SNR) is 56.48 dB. In contrast, the standard deviation of the reconstruction error by the existing nearest-interpolation method (NIPM) is 0.15 mGal and the SNR is 42.29 dB. These results have shown that the OMP algorithm can reconstruct the gravity anomaly data with higher accuracy and fewer measurements. PMID:24647125

  3. Reversal of Glaucoma Hemifield Test Results and Visual Field Features in Glaucoma.

    PubMed

    Wang, Mengyu; Pasquale, Louis R; Shen, Lucy Q; Boland, Michael V; Wellik, Sarah R; De Moraes, Carlos Gustavo; Myers, Jonathan S; Wang, Hui; Baniasadi, Neda; Li, Dian; Silva, Rafaella Nascimento E; Bex, Peter J; Elze, Tobias

    2018-03-01

    To develop a visual field (VF) feature model to predict the reversal of glaucoma hemifield test (GHT) results to within normal limits (WNL) after 2 consecutive outside normal limits (ONL) results. Retrospective cohort study. Visual fields of 44 503 eyes from 26 130 participants. Eyes with 3 or more consecutive reliable VFs measured with the Humphrey Field Analyzer (Swedish interactive threshold algorithm standard 24-2) were included. Eyes with ONL GHT results for the 2 baseline VFs were selected. We extracted 3 categories of VF features from the baseline tests: (1) VF global indices (mean deviation [MD] and pattern standard deviation), (2) mismatch between baseline VFs, and (3) VF loss patterns (archetypes). Logistic regression was applied to predict the GHT results reversal. Cross-validation was applied to evaluate the model on testing data by the area under the receiver operating characteristic curve (AUC). We ascertained clinical glaucoma status on a patient subset (n = 97) to determine the usefulness of our model. Predictive models for GHT results reversal using VF features. For the 16 604 eyes with 2 initial ONL results, the prevalence of a subsequent WNL result increased from 0.1% for MD < -12 dB to 13.8% for MD ≥-3 dB. Compared with models with VF global indices, the AUC of predictive models increased from 0.669 (MD ≥-3 dB) and 0.697 (-6 dB ≤ MD < -3 dB) to 0.770 and 0.820, respectively, by adding VF mismatch features and computationally derived VF archetypes (P < 0.001 for both). The GHT results reversal was associated with a large mismatch between baseline VFs. Moreover, the GHT results reversal was associated more with VF archetypes of nonglaucomatous loss, severe widespread loss, and lens rim artifacts. For a subset of 97 eyes, using our model to predict absence of glaucoma based on clinical evidence after 2 ONL results yielded significantly better prediction accuracy (87.7%; P < 0.001) than predicting GHT results reversal (68.8%) with a prescribed specificity 67.7%. Using VF features may predict the GHT results reversal to WNL after 2 consecutive ONL results. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Sound-direction identification, interaural time delay discrimination, and speech intelligibility advantages in noise for a bilateral cochlear implant user.

    PubMed

    Van Hoesel, Richard; Ramsden, Richard; Odriscoll, Martin

    2002-04-01

    To characterize some of the benefits available from using two cochlear implants compared with just one, sound-direction identification (ID) abilities, sensitivity to interaural time delays (ITDs) and speech intelligibility in noise were measured for a bilateral multi-channel cochlear implant user. Sound-direction ID in the horizontal plane was tested with a bilateral cochlear implant user. The subject was tested both unilaterally and bilaterally using two independent behind-the-ear ESPRIT (Cochlear Ltd.) processors, as well as bilaterally using custom research processors. Pink noise bursts were presented using an 11-loudspeaker array spanning the subject's frontal 180 degrees arc in an anechoic room. After each burst, the subject was asked to identify which loudspeaker had produced the sound. No explicit training, and no feedback were given. Presentation levels were nominally at 70 dB SPL, except for a repeat experiment using the clinical devices where the presentation levels were reduced to 60 dB SPL to avoid activation of the devices' automatic gain control (AGC) circuits. Overall presentation levels were randomly varied by +/- 3 dB. For the research processor, a "low-update-rate" and a "high-update-rate" strategy were tested. Direct measurements of ITD just noticeable differences (JNDs) were made using a 3 AFC paradigm targeting 70% correct performance on the psychometric function. Stimuli included simple, low-rate electrical pulse trains as well as high-rate pulse trains modulated at 100 Hz. Speech data comparing monaural and binaural performance in noise were also collected with both low, and high update-rate strategies on the research processors. Open-set sentences were presented from directly in front of the subject and competing multi-talker babble noise was presented from the same loudspeaker, or from a loudspeaker placed 90 degrees to the left or right of the subject. For the sound-direction ID task, monaural performance using the clinical devices showed large mean absolute errors of 81 degrees and 73 degrees, with standard deviations (averaged across all 11 loud-speakers) of 10 degrees and 17 degrees, for left and right ears, respectively. Fore bilateral device use at a presentation level of 70 dB SPL, the mean error improved to about 16 degrees with an average standard deviation of 18 degrees. When the presentation level was decreased to 60 dB SPL to avoid activation of the automatic gain control (AGC) circuits in the clinical processors, the mean response error improved further to 8 degrees with a standard deviation of 13 degrees. Further tests with the custom research processors, which had a higher stimulation rate and did not include AGCs, showed comparable response errors: around 8 or 9 degrees and a standard deviation of about 11 degrees for both update rates. The best ITD JNDs measured for this subject were between 350 to 400 microsec for simple low-rate pulse trains. Speech results showed a substantial headshadow advantage for bilateral device use when speech and noise were spatially separated, but little evidence of binaural unmasking. For spatially coincident speech and noise, listening with both ears showed similar results to listening with either side alone when loudness summation was compensated for. No significant differences were observed between binaural results for high and low update-rates in any test configuration. Only for monaural listening in one test configuration did the high rate show a small significant improvement over the low rate. Results show that even if interaural time delay cues are not well coded or perceived, bilateral implants can offer important advantages, both for speech in noise as well as for sound-direction identification.

  5. Validation of the BOD POD with hydrostatic weighing: influence of body clothing.

    PubMed

    Fields, D A; Hunter, G R; Goran, M I

    2000-02-01

    Whole body air-displacement plethysmography (BOD POD), a new body composition technique, was validated against hydrodensitometry (UWW) in 67 women wearing a one-piece swimsuit (OP) who represent a wide range of body fatness and age. Additionally, the effect of trapped isothermic air in clothing while in the BOD POD was examined by comparing different clothing schemes (a one-piece swimsuit (OP), two-piece swimsuit (TP), a hospital gown (HG), and a hospital gown previously included in a volume calibration (GC)) in a subset of 25 women. Cross-sectional data analysis. 67 healthy Caucasian females. Body density g/cm3 (Db) by BOD POD and UWW. In 67 females UWW Db (1.030+/-0.020 g/cm3) was higher (P<0.01) than BOD POD Db (1. 028+/-0.020 g/cm3). This is a difference of 1.0% fat. The R2 was 0. 94, SEE was 0.005 g/cm3 and the regression between Db by UWW and BOD POB did not significantly deviate from the line of identity. In the subset group of 25 subjects, OP Db (1.040+/-0.014 g/cm3) and TP Db (1.040+/-0.014 g/cm3) were significantly lower (P<0.01) than UWW Db (1.044+/-0.014 g/cm3) or a difference of 1.9% fat. The R2 was 0.86 and the SEE was 0.005 g/cm3 and the regression between Db by UWW and both OP and TP did not significantly deviate from the line of identity. HG Db (1.056+/-0.016 g/cm3) and GC Db (1.037+/-0.016 g/cm3) were significantly different (P<0.01) from UWW Db (1.044+/-0. 014 g/cm3). This difference in density translates to a difference of 5.5% and 3.2% fat respectively. The regression between Db by UWW and both HG and GC significantly deviated from the line of identity. This study supports the use of the BOD POD as a substitute for UWW. However, caution should be made in using the BOD POD if subjects are clothed in anything other than a tight fitting swimsuit.

  6. Acoustic Fluctuation Workshop Held at Naval Research Lab. on February 22-23 1978. Technical Review, Editorial Summary, Synopsis and Papers. Volume 2

    DTIC Science & Technology

    1979-07-02

    modulation falls off at -30 dB per oc- tave as would be expected for internal waves. jloat: (C) (1) Random course and speed produce small effect on coherence...2) Constant course and speed produce large effects. (3) Measured coherence lower than predicted. Barbour: (C) Standard deviation of fluctuations in...present characteristics of signals propagated over long range deep water paths, for which the data is currently insufficient to permit modeling. In

  7. Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.

    PubMed

    Gardiner, Stuart K; Swanson, William H; Goren, Deborah; Mansberger, Steven L; Demirel, Shaban

    2014-07-01

    Visual field testing uses high-contrast stimuli in areas of severe visual field loss. However, retinal ganglion cells saturate with high-contrast stimuli, suggesting that the probability of detecting perimetric stimuli may not increase indefinitely as contrast increases. Driven by this concept, this study examines the lower limit of perimetric sensitivity for reliable testing by standard automated perimetry. Evaluation of a diagnostic test. A total of 34 participants with moderate to severe glaucoma; mean deviation at their last clinic visit averaged -10.90 dB (range, -20.94 to -3.38 dB). A total of 75 of the 136 locations tested had a perimetric sensitivity of ≤ 19 dB. Frequency-of-seeing curves were constructed at 4 nonadjacent visual field locations by the Method of Constant Stimuli (MOCS), using 35 stimulus presentations at each of 7 contrasts. Locations were chosen a priori and included at least 2 with glaucomatous damage but a sensitivity of ≥ 6 dB. Cumulative Gaussian curves were fit to the data, first assuming a 5% false-negative rate and subsequently allowing the asymptotic maximum response probability to be a free parameter. The strength of the relation (R(2)) between perimetric sensitivity (mean of last 2 clinic visits) and MOCS sensitivity (from the experiment) for all locations with perimetric sensitivity within ± 4 dB of each selected value, at 0.5 dB intervals. Bins centered at sensitivities ≥ 19 dB always had R(2) >0.1. All bins centered at sensitivities ≤ 15 dB had R(2) <0.1, an indication that sensitivities are unreliable. No consistent conclusions could be drawn between 15 and 19 dB. At 57 of the 81 locations with perimetric sensitivity <19 dB, including 49 of the 63 locations ≤ 15 dB, the fitted asymptotic maximum response probability was <80%, consistent with the hypothesis of response saturation. At 29 of these locations the asymptotic maximum was <50%, and so contrast sensitivity (50% response rate) is undefined. Clinical visual field testing may be unreliable when visual field locations have sensitivity below approximately 15 to 19 dB because of a reduction in the asymptotic maximum response probability. Researchers and clinicians may have difficulty detecting worsening sensitivity in these visual field locations, and this difficulty may occur commonly in patients with glaucoma with moderate to severe glaucomatous visual field loss. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Free-space to few-mode-fiber coupling under atmospheric turbulence.

    PubMed

    Zheng, Donghao; Li, Yan; Chen, Erhu; Li, Beibei; Kong, Deming; Li, Wei; Wu, Jian

    2016-08-08

    High speed free space optical communication (FSOC) has taken advantages of components developed for fiber-optic communication systems. Recently, with the rapid development of few-mode-fiber based fiber communication systems, few-mode-fiber components might further promote their applications in FSOC system. The coupling efficiency between free space optical beam and few-mode fibers under atmospheric turbulence effect are investigated in this paper. Both simulation and experimental results show that, compared with single-mode fiber, the coupling efficiencies for a 2-mode fiber and a 4-mode fiber are improved by ~4 dB and ~7 dB respectively in the presence of medium moderate and strong turbulence. Compared with single-mode fiber, the relative standard deviation of received power is restrained by 51% and 66% respectively with a 4-mode and 2-mode fiber.

  9. Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes.

    PubMed

    El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N

    2003-11-01

    To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.

  10. Empirical source noise prediction method with application to subsonic coaxial jet mixing noise

    NASA Technical Reports Server (NTRS)

    Zorumski, W. E.; Weir, D. S.

    1982-01-01

    A general empirical method, developed for source noise predictions, uses tensor splines to represent the dependence of the acoustic field on frequency and direction and Taylor's series to represent the dependence on source state parameters. The method is applied to prediction of mixing noise from subsonic circular and coaxial jets. A noise data base of 1/3-octave-band sound pressure levels (SPL's) from 540 tests was gathered from three countries: United States, United Kingdom, and France. The SPL's depend on seven variables: frequency, polar direction angle, and five source state parameters: inner and outer nozzle pressure ratios, inner and outer stream total temperatures, and nozzle area ratio. A least-squares seven-dimensional curve fit defines a table of constants which is used for the prediction method. The resulting prediction has a mean error of 0 dB and a standard deviation of 1.2 dB. The prediction method is used to search for a coaxial jet which has the greatest coaxial noise benefit as compared with an equivalent single jet. It is found that benefits of about 6 dB are possible.

  11. The SIR-B observations of microwave backscatter dependence on soil moisture, surface roughness, and vegetation covers

    NASA Technical Reports Server (NTRS)

    Wang, J. R.; Shiue, J. C.; Engman, E. T.; Rusek, M.; Steinmeier, C.

    1986-01-01

    An experiment was conducted from an L-band SAR aboard Space Shuttle Challenger in October 1984 to study the microwave backscatter dependence on soil moisture, surface roughness, and vegetation cover. The results based on the analyses of an image obtained at 21-deg incidence angle show a positive correlatlion between scattering coefficient and soil moisture content, with a sensitivity comparable to that derived from the ground radar measurements reported by Ulaby et al. (1978). The surface roughness strongly affects the microwave backscatter. A factor of two change in the standard deviation of surface roughness height gives a corresponding change of about 8 dB in the scattering coefficient. The microwave backscatter also depends on the vegetation types. Under the dry soil conditions, the scattering coefficient is observed to change from about -24 dB for an alfalfa or lettuce field to about -17 dB for a mature corn field. These results suggest that observations with a SAR system of multiple frequencies and polarizations are required to unravel the effects of soil moisture, surface roughness, and vegetation cover.

  12. Application of the Vibrant Soundbridge middle-ear implant for aural atresia in patients with Treacher Collins syndrome.

    PubMed

    Lesinskas, E; Stankeviciute, V; Petrulionis, M

    2012-12-01

    To present results for the auditory rehabilitation of patients with Treacher Collins syndrome with bilateral osseous atresia, using middle-ear implantation with a Vibrant Soundbridge. Three patients underwent vibroplasty for aural atresia with moderate to severe conductive hearing loss. The pre-operative Jahrsdoerfer radiological score was 4 for all patients. Patients underwent active middle-ear implantation of a Vibrant Soundbridge implant (coupling the floating mass transducer to the rudimentary stapes or footplate distally, and positioning it adjacent to the round window membrane proximally), with audiological analysis as follow up. After implant activation, the mean air conduction threshold ± standard deviation decreased to 22.8 ± 5.5 dB HL, representing a mean functional gain of 44.5 dB. The mean word recognition score (for bisyllabic words at 65 dB SPL) increased from 0 to 97 per cent. Vibrant Soundbridge implantation is an effective hearing rehabilitation procedure in patients with Treacher Collins syndrome with bilateral osseous atresia. This is a versatile implant which can achieve coupling even in cases of severe middle-ear malformation.

  13. Individual Test Point Fluctuations of Macular Sensitivity in Healthy Eyes and Eyes With Age-Related Macular Degeneration Measured With Microperimetry.

    PubMed

    Barboni, Mirella Telles Salgueiro; Szepessy, Zsuzsanna; Ventura, Dora Fix; Németh, János

    2018-04-01

    To establish fluctuation limits, it was considered that not only overall macular sensitivity but also fluctuations of individual test points in the macula might have clinical value. Three repeated measurements of microperimetry were performed using the Standard Expert test of Macular Integrity Assessment (MAIA) in healthy subjects ( N = 12, age = 23.8 ± 1.5 years old) and in patients with age-related macular degeneration (AMD) ( N = 11, age = 68.5 ± 7.4 years old). A total of 37 macular points arranged in four concentric rings and in four quadrants were analyzed individually and in groups. The data show low fluctuation of macular sensitivity of individual test points in healthy subjects (average = 1.38 ± 0.28 dB) and AMD patients (average = 2.12 ± 0.60 dB). Lower sensitivity points are more related to higher fluctuation than to the distance from the central point. Fixation stability showed no effect on the sensitivity fluctuation. The 95th percentile of the standard deviations of healthy subjects was, on average, 2.7 dB, ranging from 1.2 to 4 dB, depending on the point tested. Point analysis and regional analysis might be considered prior to evaluating macular sensitivity fluctuation in order to distinguish between normal variation and a clinical change. S tatistical methods were used to compare repeated microperimetry measurements and to establish fluctuation limits of the macular sensitivity. This analysis could add information regarding the integrity of different macular areas and provide new insights into fixation points prior to the biofeedback fixation training.

  14. The improvement of a simple theoretical model for the prediction of the sound insulation of double leaf walls.

    PubMed

    Davy, John L

    2010-02-01

    This paper presents a revised theory for predicting the sound insulation of double leaf cavity walls that removes an approximation, which is usually made when deriving the sound insulation of a double leaf cavity wall above the critical frequencies of the wall leaves due to the airborne transmission across the wall cavity. This revised theory is also used as a correction below the critical frequencies of the wall leaves instead of a correction due to Sewell [(1970). J. Sound Vib. 12, 21-32]. It is found necessary to include the "stud" borne transmission of the window frames when modeling wide air gap double glazed windows. A minimum value of stud transmission is introduced for use with resilient connections such as steel studs. Empirical equations are derived for predicting the effective sound absorption coefficient of wall cavities without sound absorbing material. The theory is compared with experimental results for double glazed windows and gypsum plasterboard cavity walls with and without sound absorbing material in their cavities. The overall mean, standard deviation, maximum, and minimum of the differences between experiment and theory are -0.6 dB, 3.1 dB, 10.9 dB at 1250 Hz, and -14.9 dB at 160 Hz, respectively.

  15. Modified Gas Chromatographic Method to Determine Monoacylglycerol and Diacylglycerol Contents in Edible Fats and Oils.

    PubMed

    Satou, Chiemi; Goto, Hirofumi; Yamazaki, Yuya; Saitou, Katsuyoshi; Matsumoto, Shoji; Takahashi, Ou; Miyazaki, Yosuke; Ikuta, Keiichi; Yajima, Yosuke

    2017-06-01

    Monoacylglycerol (MAG) and diacylglycerol (DAG) are minor components of edible fats and oils, and they relate to the quality of these foods. The AOCS official method Cd 11b-91 has been used to determine MAG and DAG contents in fats and oils. There are, however, difficulties in the determination of MAG and DAG using this analytical procedure. Therefore, we improved this method by modifying the trimethylsilyl derivatization procedure and replacing the internal standard (IS) material. In our modified method, TMS-HT (mixture of hexamethyldisilazane and trimethylchlorosilane) was used for derivatization of MAG and DAG, which was followed by liquid-liquid extraction with water and n-hexane solution containing the IS, tricaprin. Using the modified method, we demonstrated superior repeatability in comparison with that of the AOCS method by reducing procedural difficulties. The relative standard deviation of distearin peak areas was 1.8% or 2.9% in the modified method, while it was 5.6% in the AOCS method. In addition, capillary columns, such as DB-1ht and DB-5ht could be used in this method.

  16. Fast Plane Wave 2-D Vector Flow Imaging Using Transverse Oscillation and Directional Beamforming.

    PubMed

    Jensen, Jonas; Villagomez Hoyos, Carlos Armando; Stuart, Matthias Bo; Ewertsen, Caroline; Nielsen, Michael Bachmann; Jensen, Jorgen Arendt

    2017-07-01

    Several techniques can estimate the 2-D velocity vector in ultrasound. Directional beamforming (DB) estimates blood flow velocities with a higher precision and accuracy than transverse oscillation (TO), but at the cost of a high beamforming load when estimating the flow angle. In this paper, it is proposed to use TO to estimate an initial flow angle, which is then refined in a DB step. Velocity magnitude is estimated along the flow direction using cross correlation. It is shown that the suggested TO-DB method can improve the performance of velocity estimates compared with TO, and with a beamforming load, which is 4.6 times larger than for TO and seven times smaller than for conventional DB. Steered plane wave transmissions are employed for high frame rate imaging, and parabolic flow with a peak velocity of 0.5 m/s is simulated in straight vessels at beam-to-flow angles from 45° to 90°. The TO-DB method estimates the angle with a bias and standard deviation (SD) less than 2°, and the SD of the velocity magnitude is less than 2%. When using only TO, the SD of the angle ranges from 2° to 17° and for the velocity magnitude up to 7%. Bias of the velocity magnitude is within 2% for TO and slightly larger but within 4% for TO-DB. The same trends are observed in measurements although with a slightly larger bias. Simulations of realistic flow in a carotid bifurcation model provide visualization of complex flow, and the spread of velocity magnitude estimates is 7.1 cm/s for TO-DB, while it is 11.8 cm/s using only TO. However, velocities for TO-DB are underestimated at peak systole as indicated by a regression value of 0.97 for TO and 0.85 for TO-DB. An in vivo scanning of the carotid bifurcation is used for vector velocity estimations using TO and TO-DB. The SD of the velocity profile over a cardiac cycle is 4.2% for TO and 3.2% for TO-DB.

  17. Simulation of the novel compact structure of an interferometric biosensor based on multimode interference waveguides

    NASA Astrophysics Data System (ADS)

    Xhoxhi, Moisi; Dudia, Alma; Ymeti, Aurel

    2017-05-01

    We propose the novel structure of an interferometric biosensor based on multimode interference (MMI) waveguides. We present the design of the biosensor using eigenmode expansion (EME) method in accordance with the requirements and standards of today's photonic technology. The MMI structures with a 90 nm Si3N4 core are used as power splitters with 5 outputs. The 5 high-resolution images at the end of the multimode region show high power balance. We analyze the coupling efficiency of the laser source with the structure, the excess loss and power imbalance for different compact MMI waveguides with widths ranging from 45 μm to 15 μm. For a laser source with a tolerance of +/-1mm in linearization we could achieve a coupling efficiency of 52%. MMI waveguides with tapered channels show excess loss values under 0.5 dB and power imbalance values under 0.08 dB. In addition, we show that for a 10 nm deviation of the source wavelength from its optimal value and for a 10 μm deviation of the MMI length from its optimal value, the performance of the MMI waveguides remains acceptable. Finally, we analyze the power budget of the whole biosensor structure and show that it is sufficient for the proper operation of this device.

  18. Visual field progression with frequency-doubling matrix perimetry and standard automated perimetry in patients with glaucoma and in healthy controls.

    PubMed

    Redmond, Tony; O'Leary, Neil; Hutchison, Donna M; Nicolela, Marcelo T; Artes, Paul H; Chauhan, Balwantray C

    2013-12-01

    A new analysis method called permutation of pointwise linear regression measures the significance of deterioration over time at each visual field location, combines the significance values into an overall statistic, and then determines the likelihood of change in the visual field. Because the outcome is a single P value, individualized to that specific visual field and independent of the scale of the original measurement, the method is well suited for comparing techniques with different stimuli and scales. To test the hypothesis that frequency-doubling matrix perimetry (FDT2) is more sensitive than standard automated perimetry (SAP) in identifying visual field progression in glaucoma. Patients with open-angle glaucoma and healthy controls were examined by FDT2 and SAP, both with the 24-2 test pattern, on the same day at 6-month intervals in a longitudinal prospective study conducted in a hospital-based setting. Only participants with at least 5 examinations were included. Data were analyzed with permutation of pointwise linear regression. Permutation of pointwise linear regression is individualized to each participant, in contrast to current analyses in which the statistical significance is inferred from population-based approaches. Analyses were performed with both total deviation and pattern deviation. Sixty-four patients and 36 controls were included in the study. The median age, SAP mean deviation, and follow-up period were 65 years, -2.6 dB, and 5.4 years, respectively, in patients and 62 years, +0.4 dB, and 5.2 years, respectively, in controls. Using total deviation analyses, statistically significant deterioration was identified in 17% of patients with FDT2, in 34% of patients with SAP, and in 14% of patients with both techniques; in controls these percentages were 8% with FDT2, 31% with SAP, and 8% with both. Using pattern deviation analyses, statistically significant deterioration was identified in 16% of patients with FDT2, in 17% of patients with SAP, and in 3% of patients with both techniques; in controls these values were 3% with FDT2 and none with SAP. No evidence was found that FDT2 is more sensitive than SAP in identifying visual field deterioration. In about one-third of healthy controls, age-related deterioration with SAP reached statistical significance.

  19. Acoustic response variability in automotive vehicles

    NASA Astrophysics Data System (ADS)

    Hills, E.; Mace, B. R.; Ferguson, N. S.

    2009-03-01

    A statistical analysis of a series of measurements of the audio-frequency response of a large set of automotive vehicles is presented: a small hatchback model with both a three-door (411 vehicles) and five-door (403 vehicles) derivative and a mid-sized family five-door car (316 vehicles). The sets included vehicles of various specifications, engines, gearboxes, interior trim, wheels and tyres. The tests were performed in a hemianechoic chamber with the temperature and humidity recorded. Two tests were performed on each vehicle and the interior cabin noise measured. In the first, the excitation was acoustically induced by sets of external loudspeakers. In the second test, predominantly structure-borne noise was induced by running the vehicle at a steady speed on a rough roller. For both types of excitation, it is seen that the effects of temperature are small, indicating that manufacturing variability is larger than that due to temperature for the tests conducted. It is also observed that there are no significant outlying vehicles, i.e. there are at most only a few vehicles that consistently have the lowest or highest noise levels over the whole spectrum. For the acoustically excited tests, measured 1/3-octave noise reduction levels typically have a spread of 5 dB or so and the normalised standard deviation of the linear data is typically 0.1 or higher. Regarding the statistical distribution of the linear data, a lognormal distribution is a somewhat better fit than a Gaussian distribution for lower 1/3-octave bands, while the reverse is true at higher frequencies. For the distribution of the overall linear levels, a Gaussian distribution is generally the most representative. As a simple description of the response variability, it is sufficient for this series of measurements to assume that the acoustically induced airborne cabin noise is best described by a Gaussian distribution with a normalised standard deviation between 0.09 and 0.145. There is generally considerable variability in the roller-induced noise, with individual 1/3-octave levels varying by typically 15 dB or so and with the normalised standard deviation being in the range 0.2-0.35 or more. These levels are strongly affected by wheel rim and tyre constructions. For vehicles with nominally identical wheel rims and tyres, the normalised standard deviation for 1/3-octave levels in the frequency range 40-600 Hz is 0.2 or so. The distribution of the linear roller-induced noise level in each 1/3-octave frequency band is well described by a lognormal distribution as is the overall level. As a simple description of the response variability, it is sufficient for this series of measurements to assume that the roller-induced road noise is best described by a lognormal distribution with a normalised standard deviation of 0.2 or so, but that this can be significantly affected by the tyre and rim type, especially at lower frequencies.

  20. Differential standard deviation of log-scale intensity based optical coherence tomography angiography.

    PubMed

    Shi, Weisong; Gao, Wanrong; Chen, Chaoliang; Yang, Victor X D

    2017-12-01

    In this paper, a differential standard deviation of log-scale intensity (DSDLI) based optical coherence tomography angiography (OCTA) is presented for calculating microvascular images of human skin. The DSDLI algorithm calculates the variance in difference images of two consecutive log-scale intensity based structural images from the same position along depth direction to contrast blood flow. The en face microvascular images were then generated by calculating the standard deviation of the differential log-scale intensities within the specific depth range, resulting in an improvement in spatial resolution and SNR in microvascular images compared to speckle variance OCT and power intensity differential method. The performance of DSDLI was testified by both phantom and in vivo experiments. In in vivo experiments, a self-adaptive sub-pixel image registration algorithm was performed to remove the bulk motion noise, where 2D Fourier transform was utilized to generate new images with spatial interval equal to half of the distance between two pixels in both fast-scanning and depth directions. The SNRs of signals of flowing particles are improved by 7.3 dB and 6.8 dB on average in phantom and in vivo experiments, respectively, while the average spatial resolution of images of in vivo blood vessels is increased by 21%. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Visual field defects of the contralateral eye of non-arteritic ischemic anterior optic neuropathy: are they related to sleep apnea?

    PubMed

    Aptel, Florent; Aryal-Charles, Nischal; Tamisier, Renaud; Pépin, Jean-Louis; Lesoin, Antoine; Chiquet, Christophe

    2017-06-01

    To evaluate whether obstructive sleep apnea (OSA) is responsible for the visual field defects found in the fellow eyes of patients with non-arteritic ischemic optic neuropathy (NAION). Prospective cross-sectional study. The visual fields of the fellow eyes of NAION subjects with OSA were compared to the visual fields of control OSA patients matched for OSA severity. All patients underwent comprehensive ophthalmological and general examination including Humphrey 24.2 SITA-Standard visual field and polysomnography. Visual field defects were classified according the Ischemic Optic Neuropathy Decompression Trial (IONDT) classification. From a cohort of 78 consecutive subjects with NAION, 34 unaffected fellow eyes were compared to 34 control eyes of subjects matched for OSA severity (apnea-hypopnea index [AHI] 35.5 ± 11.6 vs 35.4 ± 9.4 events per hour, respectively, p = 0.63). After adjustment for age and body mass index, all visual field parameters were significantly different between the NAION fellow eyes and those of the control OSA groups, including mean deviation (-4.5 ± 3.7 vs -1.3 ± 1.8 dB, respectively, p < 0.05), visual field index (91.6 ± 10 vs 97.4 ± 3.5%, respectively, p = 0.002), pattern standard deviation (3.7 ± 2.3 vs 2.5 ± 2 dB, respectively, p = 0.015), and number of subjects with at least one defect on the IONDT classification (20 vs 10, respectively, p < 0.05). OSA alone does not explain the visual field defects frequently found in the fellow eyes of NAION patients.

  2. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation.

    PubMed

    Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan

    2017-04-04

    A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (-1.8 and -0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (-2.95 and -3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dB m input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dB m at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dB m at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dB m input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (-48.34, -44.21, -48.34, and -46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (-45.61, -41.57, -45.01, and -45.51 dB, respectively). When five-cycle 20 dB m input power was applied, the second, third, fourth, and fifth harmonic distortions of the HVPA with the power MOSFET linearizer (-41.54, -41.80, -48.86, and -46.27 dB, respectively) were also lower than that of the HVPA without the power MOSFET linearizer (-25.85, -43.56, -49.04, and -49.24 dB, respectively). Therefore, we conclude that the power MOSFET linearizer could reduce gain deviation of the HVPA, thus reducing the echo signal harmonic distortions generated by the high-frequency ultrasonic transducers in pulse-echo instrumentation.

  3. Visual Field Defects and Retinal Ganglion Cell Losses in Human Glaucoma Patients

    PubMed Central

    Harwerth, Ronald S.; Quigley, Harry A.

    2007-01-01

    Objective The depth of visual field defects are correlated with retinal ganglion cell densities in experimental glaucoma. This study was to determine whether a similar structure-function relationship holds for human glaucoma. Methods The study was based on retinal ganglion cell densities and visual thresholds of patients with documented glaucoma (Kerrigan-Baumrind, et al.) The data were analyzed by a model that predicted ganglion cell densities from standard clinical perimetry, which were then compared to histologic cell counts. Results The model, without free parameters, produced accurate and relatively precise quantification of ganglion cell densities associated with visual field defects. For 437 sets of data, the unity correlation for predicted vs. measured cell densities had a coefficient of determination of 0.39. The mean absolute deviation of the predicted vs. measured values was 2.59 dB, the mean and SD of the distribution of residual errors of prediction was -0.26 ± 3.22 dB. Conclusions Visual field defects by standard clinical perimetry are proportional to neural losses caused by glaucoma. Clinical Relevance The evidence for quantitative structure-function relationships provides a scientific basis of interpreting glaucomatous neuropathy from visual thresholds and supports the application of standard perimetry to establish the stage of the disease. PMID:16769839

  4. The Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V.

    PubMed

    Wall, Michael; Zamba, Gideon K D; Artes, Paul H

    2018-01-01

    It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect of censoring on mean deviation (MD). In the Iowa Variability in Perimetry Study, 120 glaucoma subjects were tested every 6 months for 4 years with size III SITA Standard and size V Full Threshold. Progression was determined with three complementary techniques: pointwise linear regression (PLR), permutation of PLR, and linear regression of the MD index. All analyses were repeated on "censored'' datasets in which threshold estimates below a given criterion value were set to equal the criterion value. Our analyses confirmed previous observations that threshold estimates below 20 dB contribute much less to visual field progression than estimates above this range. These findings were broadly similar with stimulus sizes III and V. Censoring of threshold values < 20 dB has relatively little impact on the rates of visual field progression in patients with mild to moderate glaucoma. Size V, which has lower retest variability, performs at least as well as size III for longitudinal glaucoma progression analysis and appears to have a larger useful dynamic range owing to the upper sensitivity limit being higher.

  5. Variance of transionospheric VLF wave power absorption

    NASA Astrophysics Data System (ADS)

    Tao, X.; Bortnik, J.; Friedrich, M.

    2010-07-01

    To investigate the effects of D-region electron-density variance on wave power absorption, we calculate the power reduction of very low frequency (VLF) waves propagating through the ionosphere with a full wave method using the standard ionospheric model IRI and in situ observational data. We first verify the classic absorption curves of Helliwell's using our full wave code. Then we show that the IRI model gives overall smaller wave absorption compared with Helliwell's. Using D-region electron densities measured by rockets during the past 60 years, we demonstrate that the power absorption of VLF waves is subject to large variance, even though Helliwell's absorption curves are within ±1 standard deviation of absorption values calculated from data. Finally, we use a subset of the rocket data that are more representative of the D region of middle- and low-latitude VLF wave transmitters and show that the average quiet time wave absorption is smaller than that of Helliwell's by up to 100 dB at 20 kHz and 60 dB at 2 kHz, which would make the model-observation discrepancy shown by previous work even larger. This result suggests that additional processes may be needed to explain the discrepancy.

  6. Hearing results using the SMart piston prosthesis.

    PubMed

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  7. Hardwall acoustical characteristics and measurement capabilities of the NASA Lewis 9 x 15 foot low speed wind tunnel

    NASA Technical Reports Server (NTRS)

    Rentz, P. E.

    1976-01-01

    Experimental evaluations of the acoustical characteristics and source sound power and directionality measurement capabilities of the NASA Lewis 9 x 15 foot low speed wind tunnel in the untreated or hardwall configuration were performed. The results indicate that source sound power estimates can be made using only settling chamber sound pressure measurements. The accuracy of these estimates, expressed as one standard deviation, can be improved from + or - 4 db to + or - 1 db if sound pressure measurements in the preparation room and diffuser are also used and source directivity information is utilized. A simple procedure is presented. Acceptably accurate measurements of source direct field acoustic radiation were found to be limited by the test section reverberant characteristics to 3.0 feet for omni-directional and highly directional sources. Wind-on noise measurements in the test section, settling chamber and preparation room were found to depend on the sixth power of tunnel velocity. The levels were compared with various analytic models. Results are presented and discussed.

  8. Optimization of an Optical Inspection System Based on the Taguchi Method for Quantitative Analysis of Point-of-Care Testing

    PubMed Central

    Yeh, Chia-Hsien; Zhao, Zi-Qi; Shen, Pi-Lan; Lin, Yu-Cheng

    2014-01-01

    This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP). PMID:25256108

  9. Characterizing the temporal variability of L-band backscatter using dense UAVSAR time-series in preparation for the NISAR mission

    NASA Astrophysics Data System (ADS)

    Lavalle, M.; Lee, A.; Shiroma, G. X. H.; Rosen, P. A.

    2017-12-01

    The NASA-ISRO SAR (NISAR) mission will deliver unprecedented global maps of L-band HH/HV backscatter every 12 days with resolution ranging from a few to tens of meters in support of ecosystem, solid Earth and cryosphere science and applications. Understanding and modeling the temporal variability of L-band backscatter over temporal scales of years, months and days is critical for developing retrieval algorithms that can robustly extract the biophysical variables of interest (e.g., forest biomass, soil moisture, etc.) from NISAR time series. In this talk, we will focus on the 5-year time series of 60 JPL/UAVSAR polarimetric images collected near the Sacramento Delta to characterize the inter-annual, seasonal and short-scale variability of the L-band polarimetric backscatter for a broad range of land cover types. Our preliminary analysis reveals that backscatter from man-made structures is very stable over time, whereas backscatter from bare soil and herbaceous vegetation fluctuates over time with standard deviation of 2.3 dB. Land-cover classes with larger biomass such as trees and tall vegetation show about 1.5 dB standard deviation in temporal backscatter variability. Closer examination of high-spatial resolution UAVSAR imagery reveal also that vegetation structure, speckle noise and horizontal forest heterogeneity in the Sacramento Delta area can significantly affect the point-wise backscatter value. In our talk, we will illustrate the long UAVSAR time series, describe our data analysis strategy, show the results of polarimetric variability for different land cover classes and number of looks, and discuss the implications for the development of NISAR L2/L3 retrieval algorithms of ecosystem science.

  10. [Determination of buprofezin, methamidophos, acephate, and triazophos residues in Chinese tea samples by gas chromatography].

    PubMed

    Zhang, Shuiba; Yi, Jun; Ye, Jianglei; Zheng, Wenhui; Cai, Xueqin; Gong, Zhenbin

    2004-03-01

    A method has been developed for the simultaneous determination of buprofezin, methamidophos, acephate and triazophos residues in Chinese tea samples. The pesticide residues were extracted from tea samples with a mixture of ethyl acetate and n-hexane (50:50, v/v) at 45 degrees C. The extracts were subsequently treated with a column packed with 40 mg of active carbon by gradient elution with ethyl acetate and n-hexane. Buprofenzin and the three organophosphorus pesticides were analyzed by gas chromatography using a DB-210 capillary column and a nitrogen-phosphorus detector. The recoveries for spiked standards were 73.4%-96.9%. The relative standard deviations were all within 4.63%. The limits of quantitation (3sigma) in the tea samples were about 7.0-12.0 microg/kg.

  11. Results of Outdoor to Indoor Propagation Measurements from 5-32GHz

    NASA Technical Reports Server (NTRS)

    Houts, Jacquelynne R.; McDonough, Ryan S.

    2016-01-01

    The demand for wireless services has increased exponentially in the last few years and shows no signs of slowing in the near future. In order for the next generation wireless to provide seamless access, whether the user is indoors or out, a thorough understanding and validation of models describing the impact of building entry loss (BEL) is required. This information is currently lacking and presents a challenge for most system designers. For this reason empirical data is needed to assess the impact of BEL at frequencies that are being explored for future mobile broadband applications This paper present the results of measurements of outdoor-to-indoor propagation from 5-32 GHz in three different buildings. The first is a newer building that is similar in construction to modern residential home. The second is an older commercial office building. The last building is a very new commercial office building built using modern green building techniques. These three buildings allow for the measurement of propagation losses through both modern and older materials; such as glass windows and exterior block and siding. Initial results found that at particular spatial locations the BEL could be less than 1dB or more than 70dB with free space losses discounted (this is likely influenced by multipath). Additionally, it was observed that the PDF distributions of a majority of the measurements trended toward log-normal with means and standard deviations ranging from 8-38dB and 6-14dB, respectively.

  12. How does glaucoma look?: patient perception of visual field loss.

    PubMed

    Crabb, David P; Smith, Nicholas D; Glen, Fiona C; Burton, Robyn; Garway-Heath, David F

    2013-06-01

    To explore patient perception of vision loss in glaucoma and, specifically, to test the hypothesis that patients do not recognize their impairment as a black tunnel effect or as black patches in their field of view. Clinic-based cross-sectional study. Fifty patients (age range, 52-82 years) with visual acuity better than 20/30 and with a range of glaucomatous visual field (VF) defects in both eyes, excluding those with very advanced disease (perimetrically blind). Participants underwent monocular VF testing in both eyes using a Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA; 24-2 Swedish interactive threshold algorithm standard tests) and other tests of visual function. Participants took part in a recorded interview during which they were asked if they were aware of their VF loss; if so, there were encouraged to describe it in their own words. Participants were shown 6 images modified in a variety of ways on a computer monitor and were asked to select the image that most closely represented their perception of their VF loss. Forced choice of an image best representing glaucomatous vision impairment. Participants had a range of VF defect severity: average HFA mean deviation was -8.7 dB (standard deviation [SD], 5.8 dB) and -10.5 dB (SD, 7.1 dB) in the right and left eyes, respectively. Thirteen patients (26%; 95% confidence interval [CI], 15%-40%) reported being completely unaware of their vision loss. None of the patients chose the images with a distinct black tunnel effect or black patches. Only 2 patients (4%; 95% CI, 0%-14%) chose the image with a tunnel effect with blurred edges. An image depicting blurred patches and another with missing patches was chosen by 54% (95% CI, 39%-68%) and 16% (95% CI, 7%-29%) of the patients, respectively. Content analysis of the transcripts from the recorded interviews indicated a frequent use of descriptors of visual symptoms associated with reported blur and missing features. Patients with glaucoma do not perceive their vision loss as a black tunnel effect or as black patches masking their field of view. These findings are important in the context of depicting the effects of glaucomatous vision loss and raising awareness for glaucoma detection. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. risk for sudden death.

    PubMed

    Acoltzin-Vidal, Cuauhtémoc; Rabling-Arellanos, Elizabeth

    2018-01-01

    Prolongation of the descending branch of the T-wave in the electrocardiogram (ECG) has been identified to be able to determine the risk for sudden death of cardiac origin, but its importance in the general population is not known. To provide a tool for easy acquisition and effective application to identify the risk of sudden death in the general population. We measured the dbT/jT index (descending branch of the T wave/space between the j point and the end of T), and it was found to be completely normal in 400 ECGs, 656 had alterations that don't affect ventricular repolarization, and 82 had branch block. We carried out the Z transformation of the nonparametric distribution curves and calculated the Z ratio to data far from the mean value. The distribution was asymmetric, with no difference in the three groups. The Z transformation showed a mean value of 30 ± 7, which suggests that 95% of the population has a dbT/jT index < 0.45. dbT/jT index results > 0.44 are beyond two standard deviations and are therefore abnormal, which should prompt specialized assessment in order to determine if there is risk for death in the carrier. Copyright: © 2018 SecretarÍa de Salud.

  14. Use of the 'real-ear to dial difference' to derive real-ear SPL from hearing level obtained with insert earphones.

    PubMed

    Munro, K J; Lazenby, A

    2001-10-01

    The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  15. Backscattering Measurement From a Single Microdroplet

    PubMed Central

    Lee, Jungwoo; Chang, Jin Ho; Jeong, Jong Seob; Lee, Changyang; Teh, Shia-Yen; Lee, Abraham; Shung, K. Kirk

    2011-01-01

    Backscattering measurements for acoustically trapped lipid droplets were undertaken by employing a P[VDF-TrFE] broadband transducer of f-number = 1, with a bandwidth of 112%. The wide bandwidth allowed the transmission of the 45 MHz trapping signal and the 15 MHz sensing signal using the same transducer. Tone bursts at 45 MHz were first transmitted by the transducer to hold a single droplet at the focus (or the center of the trap) and separate it from its neighboring droplets by translating the transducer perpendicularly to the beam axis. Subsequently, 15 MHz probing pulses were sent to the trapped droplet and the backscattered RF echo signal received by the same transducer. The measured beam width at 15 MHz was measured to be 120 μm. The integrated backscatter (IB) coefficient of an individual droplet was determined within the 6-dB bandwidth of the transmit pulse by normalizing the power spectrum of the RF signal to the reference spectrum obtained from a flat reflector. The mean IB coefficient for droplets with a 64 μm average diameter (denoted as cluster A) was −107 dB, whereas it was −93 dB for 90-μm droplets (cluster B). The standard deviation was 0.9 dB for each cluster. The experimental values were then compared with those computed with the T-matrix method and a good agreement was found: the difference was as small as 1 dB for both clusters. These results suggest that this approach might be useful as a means for measuring ultrasonic backscattering from a single microparticle, and illustrate the potential of acoustic sensing for cell sorting. PMID:21507767

  16. The Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V

    PubMed Central

    Zamba, Gideon K. D.; Artes, Paul H.

    2018-01-01

    Purpose It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect of censoring on mean deviation (MD). Methods In the Iowa Variability in Perimetry Study, 120 glaucoma subjects were tested every 6 months for 4 years with size III SITA Standard and size V Full Threshold. Progression was determined with three complementary techniques: pointwise linear regression (PLR), permutation of PLR, and linear regression of the MD index. All analyses were repeated on “censored'' datasets in which threshold estimates below a given criterion value were set to equal the criterion value. Results Our analyses confirmed previous observations that threshold estimates below 20 dB contribute much less to visual field progression than estimates above this range. These findings were broadly similar with stimulus sizes III and V. Conclusions Censoring of threshold values < 20 dB has relatively little impact on the rates of visual field progression in patients with mild to moderate glaucoma. Size V, which has lower retest variability, performs at least as well as size III for longitudinal glaucoma progression analysis and appears to have a larger useful dynamic range owing to the upper sensitivity limit being higher. PMID:29356822

  17. An improved method for predicting the effects of flight on jet mixing noise

    NASA Technical Reports Server (NTRS)

    Stone, J. R.

    1979-01-01

    A method for predicting the effects of flight on jet mixing noise has been developed on the basis of the jet noise theory of Ffowcs-Williams (1963) and data derived from model-jet/free-jet simulated flight tests. Predicted and experimental values are compared for the J85 turbojet engine on the Bertin Aerotrain, the low-bypass refanned JT8D engine on a DC-9, and the high-bypass JT9D engine on a DC-10. Over the jet velocity range from 280 to 680 m/sec, the predictions show a standard deviation of 1.5 dB.

  18. SeeDB: Efficient Data-Driven Visualization Recommendations to Support Visual Analytics

    PubMed Central

    Vartak, Manasi; Rahman, Sajjadur; Madden, Samuel; Parameswaran, Aditya; Polyzotis, Neoklis

    2015-01-01

    Data analysts often build visualizations as the first step in their analytical workflow. However, when working with high-dimensional datasets, identifying visualizations that show relevant or desired trends in data can be laborious. We propose SeeDB, a visualization recommendation engine to facilitate fast visual analysis: given a subset of data to be studied, SeeDB intelligently explores the space of visualizations, evaluates promising visualizations for trends, and recommends those it deems most “useful” or “interesting”. The two major obstacles in recommending interesting visualizations are (a) scale: evaluating a large number of candidate visualizations while responding within interactive time scales, and (b) utility: identifying an appropriate metric for assessing interestingness of visualizations. For the former, SeeDB introduces pruning optimizations to quickly identify high-utility visualizations and sharing optimizations to maximize sharing of computation across visualizations. For the latter, as a first step, we adopt a deviation-based metric for visualization utility, while indicating how we may be able to generalize it to other factors influencing utility. We implement SeeDB as a middleware layer that can run on top of any DBMS. Our experiments show that our framework can identify interesting visualizations with high accuracy. Our optimizations lead to multiple orders of magnitude speedup on relational row and column stores and provide recommendations at interactive time scales. Finally, we demonstrate via a user study the effectiveness of our deviation-based utility metric and the value of recommendations in supporting visual analytics. PMID:26779379

  19. SeeDB: Efficient Data-Driven Visualization Recommendations to Support Visual Analytics.

    PubMed

    Vartak, Manasi; Rahman, Sajjadur; Madden, Samuel; Parameswaran, Aditya; Polyzotis, Neoklis

    2015-09-01

    Data analysts often build visualizations as the first step in their analytical workflow. However, when working with high-dimensional datasets, identifying visualizations that show relevant or desired trends in data can be laborious. We propose SeeDB, a visualization recommendation engine to facilitate fast visual analysis: given a subset of data to be studied, SeeDB intelligently explores the space of visualizations, evaluates promising visualizations for trends, and recommends those it deems most "useful" or "interesting". The two major obstacles in recommending interesting visualizations are (a) scale : evaluating a large number of candidate visualizations while responding within interactive time scales, and (b) utility : identifying an appropriate metric for assessing interestingness of visualizations. For the former, SeeDB introduces pruning optimizations to quickly identify high-utility visualizations and sharing optimizations to maximize sharing of computation across visualizations. For the latter, as a first step, we adopt a deviation-based metric for visualization utility, while indicating how we may be able to generalize it to other factors influencing utility. We implement SeeDB as a middleware layer that can run on top of any DBMS. Our experiments show that our framework can identify interesting visualizations with high accuracy. Our optimizations lead to multiple orders of magnitude speedup on relational row and column stores and provide recommendations at interactive time scales. Finally, we demonstrate via a user study the effectiveness of our deviation-based utility metric and the value of recommendations in supporting visual analytics.

  20. The repeatability of mean defect with size III and size V standard automated perimetry.

    PubMed

    Wall, Michael; Doyle, Carrie K; Zamba, K D; Artes, Paul; Johnson, Chris A

    2013-02-15

    The mean defect (MD) of the visual field is a global statistical index used to monitor overall visual field change over time. Our goal was to investigate the relationship of MD and its variability for two clinically used strategies (Swedish Interactive Threshold Algorithm [SITA] standard size III and full threshold size V) in glaucoma patients and controls. We tested one eye, at random, for 46 glaucoma patients and 28 ocularly healthy subjects with Humphrey program 24-2 SITA standard for size III and full threshold for size V each five times over a 5-week period. The standard deviation of MD was regressed against the MD for the five repeated tests, and quantile regression was used to show the relationship of variability and MD. A Wilcoxon test was used to compare the standard deviations of the two testing methods following quantile regression. Both types of regression analysis showed increasing variability with increasing visual field damage. Quantile regression showed modestly smaller MD confidence limits. There was a 15% decrease in SD with size V in glaucoma patients (P = 0.10) and a 12% decrease in ocularly healthy subjects (P = 0.08). The repeatability of size V MD appears to be slightly better than size III SITA testing. When using MD to determine visual field progression, a change of 1.5 to 4 decibels (dB) is needed to be outside the normal 95% confidence limits, depending on the size of the stimulus and the amount of visual field damage.

  1. Comparison of Short- and Long-term Hearing Outcomes of Successful Inlay Cartilage Tympanoplasty Between Small and Large Eardrum Perforations.

    PubMed

    Wu, Pei-Wen; Wang, Wen-Hung; Huang, Chi-Che; Lee, Ta-Jen; Huang, Chien-Chia

    2015-12-01

    To compare the short- and long-term hearing outcomes after successful inlay cartilage tympanoplasty between patients with small (≤25%) and large (≥50%) eardrums perforations. This is a retrospective case series study conducted in a tertiary referral center. Twenty-five patients who underwent 27 procedures were enrolled. Their mean age was 60.26 years (range, 42 to 76 years). The mean follow-up time was 18.86 months (range, 12.30 to 35.83 months). The preoperative, initial postoperative, and long-term hearing results in patients with total repair of the eardrum were analyzed. In the small size group, the average (±standard deviation) air-bone gap (ABG) closure was 1.08±7.53 dB in the short-term and 2.33±11.56 dB in the long-term hearing examinations. There was no difference between short- and long-term ABG closure (P=0.689). In the large size group, the average ABG closure was 9.77±9.40 dB in the short-term and 16.25±6.01 dB in the long-term hearing examinations. There was a significant difference between short- and long-term ABG closure (P=0.029). Patients with large perforations have continuous hearing improvement and ABG closure for more than one year. In contrast, the short- and long-term postoperative ABGs are almost the same in patients with small perforations. More long-term postoperative follow-up of hearing results is necessary for large perforations.

  2. CT, MR, and ultrasound image artifacts from prostate brachytherapy seed implants: The impact of seed size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Andrew K. H.; Basran, Parminder S.; Thomas, Steven D.

    Purpose: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 {sup 125}I sources. Methods: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds andmore » the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. Results: With the thin seeds, CT image noise was reduced from 48.5 {+-} 0.2 to 32.0 {+-} 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 {+-} 17.1 dB for the thin seed images and 50.0 {+-} 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average ({+-}SD) of 7.0 {+-} 3.5 manual corrections in seed positions for the thin seed scans and 3.0 {+-} 1.2 manual corrections in seed positions for the standard seed scans. The average error in seed placement was 1.2 mm for both seed types and the maximum error in seed placement was 2.1 mm for the thin seed scans and 1.8 mm for the standard seed scans. Conclusions: The 9011 thin seeds yielded significantly improved image quality for CT and US images but no significant differences in MR image quality.« less

  3. Accuracy of Noninvasive Estimation Techniques for the State of the Cochlear Amplifier

    NASA Astrophysics Data System (ADS)

    Dalhoff, Ernst; Gummer, Anthony W.

    2011-11-01

    Estimation of the function of the cochlea in human is possible only by deduction from indirect measurements, which may be subjective or objective. Therefore, for basic research as well as diagnostic purposes, it is important to develop methods to deduce and analyse error sources of cochlear-state estimation techniques. Here, we present a model of technical and physiologic error sources contributing to the estimation accuracy of hearing threshold and the state of the cochlear amplifier and deduce from measurements of human that the estimated standard deviation can be considerably below 6 dB. Experimental evidence is drawn from two partly independent objective estimation techniques for the auditory signal chain based on measurements of otoacoustic emissions.

  4. Test-retest reliability of the Toy Discrimination Test with a masker of noise or babble in children with hearing impairment.

    PubMed

    Lovett, Rosemary; Summerfield, Quentin; Vickers, Deborah

    2013-06-01

    The Toy Discrimination Test measures children's ability to discriminate spoken words. Previous assessments of reliability tested children with normal hearing or mild hearing impairment, and most studies used a version of the test without a masking sound. We assessed test-retest reliability for children with hearing impairment using maskers of broadband noise and two-talker babble. Stimuli were presented from a loudspeaker. The signal-to-noise ratio (SNR) was varied adaptively to estimate the speech-reception threshold (SRT) corresponding to 70.7% correct performance. Participants completed each masked condition twice. Fifty-five children with permanent hearing impairment participated, aged 3.0 to 6.3 years. Thirty-four children used acoustic hearing aids; 21 children used cochlear implants. For the noise masker, the within-subject standard deviation of SRTs was 2.4 dB, and the correlation between first and second SRT was + 0.73. For the babble masker, corresponding values were 2.7 dB and + 0.60. Reliability was similar for children with hearing aids and children with cochlear implants. The results can inform the interpretation of scores from individual children. If a child completes a condition twice in different listening situations (e.g. aided and unaided), a difference between scores ≥ 7.5 dB would be statistically significant (p <.05).

  5. Effect of acetazolamide on visual function in patients with idiopathic intracranial hypertension and mild visual loss: the idiopathic intracranial hypertension treatment trial.

    PubMed

    Wall, Michael; McDermott, Michael P; Kieburtz, Karl D; Corbett, James J; Feldon, Steven E; Friedman, Deborah I; Katz, David M; Keltner, John L; Schron, Eleanor B; Kupersmith, Mark J

    Acetazolamide is commonly used to treat idiopathic intracranial hypertension (IIH), but there is insufficient information to establish an evidence base for its use. To determine whether acetazolamide is beneficial in improving vision when added to a low-sodium weight reduction diet in patients with IIH and mild visual loss. Multicenter, randomized, double-masked, placebo-controlled study of acetazolamide in 165 participants with IIH and mild visual loss who received a low-sodium weight-reduction diet. Participants were enrolled at 38 academic and private practice sites in North America from March 2010 to November 2012 and followed up for 6 months (last visit in June 2013). All participants met the modified Dandy criteria for IIH and had a perimetric mean deviation (PMD) between -2 dB and -7 dB. The mean age was 29 years and all but 4 participants were women. Low-sodium weight-reduction diet plus the maximally tolerated dosage of acetazolamide (up to 4 g/d) or matching placebo for 6 months. The planned primary outcome variable was the change in PMD from baseline to month 6 in the most affected eye, as measured by Humphrey Field Analyzer. Perimetric mean deviation is a measure of global visual field loss (mean deviation from age-corrected normal values), with a range of 2 to -32 dB; larger negative values indicate greater vision loss. Secondary outcome variables included changes in papilledema grade, quality of life (Visual Function Questionnaire 25 [VFQ-25] and 36-Item Short Form Health Survey), headache disability, and weight at month 6. The mean improvement in PMD was greater with acetazolamide (1.43 dB, from -3.53 dB at baseline to -2.10 dB at month 6; n = 86) than with placebo (0.71 dB, from -3.53 dB to -2.82 dB; n = 79); the difference was 0.71 dB (95% CI, 0 to 1.43 dB; P = .050). Mean improvements in papilledema grade (acetazolamide: -1.31, from 2.76 to 1.45; placebo: -0.61, from 2.76 to 2.15; treatment effect, -0.70; 95% CI, -0.99 to -0.41; P < .001) and vision-related quality of life as measured by the National Eye Institute VFQ-25 (acetazolamide: 8.33, from 82.97 to 91.30; placebo: 1.98, from 82.97 to 84.95; treatment effect, 6.35; 95% CI, 2.22 to 10.47; P = .003) and its 10-item neuro-ophthalmic supplement (acetazolamide: 9.82, from 75.45 to 85.27; placebo: 1.59, from 75.45 to 77.04; treatment effect, 8.23; 95% CI, 3.89 to 12.56; P < .001) were also observed with acetazolamide. Participants assigned to acetazolamide also experienced a reduction in weight (acetazolamide: -7.50 kg, from 107.72 kg to 100.22 kg; placebo: -3.45 kg, from 107.72 kg to 104.27 kg; treatment effect, -4.05 kg, 95% CI, -6.27 to -1.83 kg; P < .001). In patients with IIH and mild visual loss, the use of acetazolamide with a low-sodium weight-reduction diet compared with diet alone resulted in modest improvement in visual field function. The clinical importance of this improvement remains to be determined. clinicaltrials.gov Identifier: NCT01003639.

  6. Multiplane wave imaging increases signal-to-noise ratio in ultrafast ultrasound imaging.

    PubMed

    Tiran, Elodie; Deffieux, Thomas; Correia, Mafalda; Maresca, David; Osmanski, Bruno-Felix; Sieu, Lim-Anna; Bergel, Antoine; Cohen, Ivan; Pernot, Mathieu; Tanter, Mickael

    2015-11-07

    Ultrafast imaging using plane or diverging waves has recently enabled new ultrasound imaging modes with improved sensitivity and very high frame rates. Some of these new imaging modalities include shear wave elastography, ultrafast Doppler, ultrafast contrast-enhanced imaging and functional ultrasound imaging. Even though ultrafast imaging already encounters clinical success, increasing even more its penetration depth and signal-to-noise ratio for dedicated applications would be valuable. Ultrafast imaging relies on the coherent compounding of backscattered echoes resulting from successive tilted plane waves emissions; this produces high-resolution ultrasound images with a trade-off between final frame rate, contrast and resolution. In this work, we introduce multiplane wave imaging, a new method that strongly improves ultrafast images signal-to-noise ratio by virtually increasing the emission signal amplitude without compromising the frame rate. This method relies on the successive transmissions of multiple plane waves with differently coded amplitudes and emission angles in a single transmit event. Data from each single plane wave of increased amplitude can then be obtained, by recombining the received data of successive events with the proper coefficients. The benefits of multiplane wave for B-mode, shear wave elastography and ultrafast Doppler imaging are experimentally demonstrated. Multiplane wave with 4 plane waves emissions yields a 5.8  ±  0.5 dB increase in signal-to-noise ratio and approximately 10 mm in penetration in a calibrated ultrasound phantom (0.7 d MHz(-1) cm(-1)). In shear wave elastography, the same multiplane wave configuration yields a 2.07  ±  0.05 fold reduction of the particle velocity standard deviation and a two-fold reduction of the shear wave velocity maps standard deviation. In functional ultrasound imaging, the mapping of cerebral blood volume results in a 3 to 6 dB increase of the contrast-to-noise ratio in deep structures of the rodent brain.

  7. Visual field progression in glaucoma: what is the specificity of the Guided Progression Analysis?

    PubMed

    Artes, Paul H; O'Leary, Neil; Nicolela, Marcelo T; Chauhan, Balwantray C; Crabb, David P

    2014-10-01

    To estimate the specificity of the Guided Progression Analysis (GPA) (Carl Zeiss Meditec, Dublin, CA) in individual patients with glaucoma. Observational cohort study. Thirty patients with open-angle glaucoma. In 30 patients with open-angle glaucoma, 1 eye (median mean deviation [MD], -2.5 decibels [dB]; interquartile range, -4.4 to -1.3 dB) was tested 12 times over 3 months (Humphrey Field Analyzer, Carl Zeiss Meditec; SITA Standard, 24-2). "Possible progression" and "likely progression" were determined with the GPA. These analyses were repeated after the order of the tests had been randomly rearranged (1000 unique permutations). Rate of false-positive alerts of "possible progression" and "likely progression" with the GPA. On average, the specificity of the GPA "likely progression" alert was high-for the entire sample, the mean rate of false-positive alerts after 10 follow-up tests was 2.6%. With "possible progression," the specificity was considerably lower (false-positive rate, 18.5%). Most important, the cumulative rate of false-positive alerts varied substantially among patients, from <1% to 80% with "possible progression" and from <0.1% to 20% with "likely progression." Factors associated with false-positive alerts were visual field variability (standard deviation of MD, Spearman's rho = 0.41, P<0.001) and the reliability indices (proportion of false-positive and false-negative responses, fixation losses, rho>0.31, P≤0.10). On average, progression criteria currently used in the GPA have high specificity, but some patients are more likely to show false-positive alerts than others. This is a natural consequence of population-based change criteria and may not matter in clinical trials and studies in which large groups of patients are compared. However, it must be considered when the GPA is used in clinical practice where specificity needs to be controlled for individual patients. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Evaluation of the Effect of Noise on the Rate of Errors and Speed of Work by the Ergonomic Test of Two-Hand Co-Ordination

    PubMed Central

    Habibi, Ehsanollah; Dehghan, Habibollah; Dehkordy, Sina Eshraghy; Maracy, Mohammad Reza

    2013-01-01

    Background: Among the most important and effective factors affecting the efficiency of the human workforce are accuracy, promptness, and ability. In the context of promoting levels and quality of productivity, the aim of this study was to investigate the effects of exposure to noise on the rate of errors, speed of work, and capability in performing manual activities. Methods: This experimental study was conducted on 96 students (52 female and 44 male) of the Isfahan Medical Science University with the average and standard deviations of age, height, and weight of 22.81 (3.04) years, 171.67 (8.51) cm, and 65.05 (13.13) kg, respectively. Sampling was conducted with a randomized block design. Along with controlling for intervening factors, a combination of sound pressure levels [65 dB (A), 85 dB (A), and 95 dB (A)] and exposure times (0, 20, and 40) were used for evaluation of precision and speed of action of the participants, in the ergonomic test of two-hand coordination. Data was analyzed by SPSS18 software using a descriptive and analytical statistical method by analysis of covariance (ANCOVA) repeated measures. Results: The results of this study showed that increasing sound pressure level from 65 to 95 dB in network ‘A’ increased the speed of work (P < 0.05). Increase in the exposure time (0 to 40 min of exposure) and gender showed no significant differences statistically in speed of work (P > 0.05). Male participants got annoyed from the noise more than females. Also, increase in sound pressure level increased the rate of error (P < 0.05). Conclusions: According to the results of this research, increasing the sound pressure level decreased efficiency and increased the errors and in exposure to sounds less than 85 dB in the beginning, the efficiency decreased initially and then increased in a mild slope. PMID:23930164

  9. Cardiac autonomic regulation during exposure to auditory stimulation with classical baroque or heavy metal music of different intensities.

    PubMed

    Amaral, Joice A T; Nogueira, Marcela L; Roque, Adriano L; Guida, Heraldo L; De Abreu, Luiz Carlos; Raimundo, Rodrigo Daminello; Vanderlei, Luiz Carlos M; Ribeiro, Vivian L; Ferreira, Celso; Valenti, Vitor E

    2014-03-01

    The effects of chronic music auditory stimulation on the cardiovascular system have been investigated in the literature. However, data regarding the acute effects of different styles of music on cardiac autonomic regulation are lacking. The literature has indicated that auditory stimulation with white noise above 50 dB induces cardiac responses. We aimed to evaluate the acute effects of classical baroque and heavy metal music of different intensities on cardiac autonomic regulation. The study was performed in 16 healthy men aged 18-25 years. All procedures were performed in the same soundproof room. We analyzed heart rate variability (HRV) in time (standard deviation of normal-to-normal R-R intervals [SDNN], root-mean square of differences [RMSSD] and percentage of adjacent NN intervals with a difference of duration greater than 50 ms [pNN50]) and frequency (low frequency [LF], high frequency [HF] and LF/HF ratio) domains. HRV was recorded at rest for 10 minutes. Subsequently, the volunteers were exposed to one of the two musical styles (classical baroque or heavy metal music) for five minutes through an earphone, followed by a five-minute period of rest, and then they were exposed to the other style for another five minutes. The subjects were exposed to three equivalent sound levels (60-70dB, 70-80dB and 80-90dB). The sequence of songs was randomized for each individual. Auditory stimulation with heavy metal music did not influence HRV indices in the time and frequency domains in the three equivalent sound level ranges. The same was observed with classical baroque musical auditory stimulation with the three equivalent sound level ranges. Musical auditory stimulation of different intensities did not influence cardiac autonomic regulation in men.

  10. Aerodynamic and acoustic investigation of inverted velocity profile coannular exhaust nozzle models and development of aerodynamic and acoustic prediction procedures

    NASA Technical Reports Server (NTRS)

    Larson, R. S.; Nelson, D. P.; Stevens, B. S.

    1979-01-01

    Five co-annular nozzle models, covering a systematic variation of nozzle geometry, were tested statically over a range of exhaust conditions including inverted velocity profile (IVP) (fan to primary stream velocity ratio 1) and non IVP profiles. Fan nozzle pressure ratio (FNPR) was varied from 1.3 to 4.1 at primary nozzle pressure ratios (PNPR) of 1.53 and 2.0. Fan stream temperatures of 700 K (1260 deg R) and 1089 K(1960 deg R) were tested with primary stream temperatures of 700 K (1260 deg R), 811 K (1460 deg R), and 1089 K (1960 deg R). At fan and primary stream velocities of 610 and 427 m/sec (2000 and 1400 ft/sec), respectively, increasing fan radius ratio from 0.69 to 0.83 reduced peak perceived noise level (PNL) 3 dB, and an increase in primary radius ratio from 0 to 0.81 (fan radius ratio constant at 0.83) reduced peak PNL an additional 1.0 dB. There were no noise reductions at a fan stream velocity of 853 m/sec (2800 ft/sec). Increasing fan radius ratio from 0.69 to 0.83 reduced nozzle thrust coefficient 1.2 to 1.5% at a PNPR of 1.53, and 1.7 to 2.0% at a PNPR of 2.0. The developed acoustic prediction procedure collapsed the existing data with standard deviation varying from + or - 8 dB to + or - 7 dB. The aerodynamic performance prediction procedure collapsed thrust coefficient measurements to within + or - .004 at a FNPR of 4.0 and a PNPR of 2.0.

  11. Severity of Visual Field Loss and Health Related Quality of Life

    PubMed Central

    McKean-Cowdin, Roberta; Varma, Rohit; Wu, Joanne; Hays, Ron D.; Azen, Stanley P.

    2009-01-01

    Purpose To examine the association between severity of visual field loss (VFL) and self-reported health-related quality of life (HRQOL) in a population-based sample. Design Population-based cross-sectional study. Methods Participants in the Los Angeles Latino Eye Study underwent a comprehensive ophthalmic examination including visual field testing using the Humphrey Automated Field Analyzer II (SITA Standard 24-2). Mean Deviation (MD) scores were used to determine severity of VFL both as a continuous variable and stratified by severity: no VFL (MD≥ − 2 decibels [dB]), mild VFL (6dB

  12. Personalized Prediction of Glaucoma Progression Under Different Target Intraocular Pressure Levels Using Filtered Forecasting Methods.

    PubMed

    Kazemian, Pooyan; Lavieri, Mariel S; Van Oyen, Mark P; Andrews, Chris; Stein, Joshua D

    2018-04-01

    To generate personalized forecasts of how patients with open-angle glaucoma (OAG) experience disease progression at different intraocular pressure (IOP) levels to aid clinicians with setting personalized target IOPs. Secondary analyses using longitudinal data from 2 randomized controlled trials. Participants with moderate or advanced OAG from the Collaborative Initial Glaucoma Treatment Study (CIGTS) or the Advanced Glaucoma Intervention Study (AGIS). By using perimetric and tonometric data from trial participants, we developed and validated Kalman Filter (KF) models for fast-, slow-, and nonprogressing patients with OAG. The KF can generate personalized and dynamically updated forecasts of OAG progression under different target IOP levels. For each participant, we determined how mean deviation (MD) would change if the patient maintains his/her IOP at 1 of 7 levels (6, 9, 12, 15, 18, 21, or 24 mmHg) over the next 5 years. We also model and predict changes to MD over the same time horizon if IOP is increased or decreased by 3, 6, and 9 mmHg from the level attained in the trials. Personalized estimates of the change in MD under different target IOP levels. A total of 571 participants (mean age, 64.2 years; standard deviation, 10.9) were followed for a mean of 6.5 years (standard deviation, 2.8). Our models predicted that, on average, fast progressors would lose 2.1, 6.7, and 11.2 decibels (dB) MD under target IOPs of 6, 15, and 24 mmHg, respectively, over 5 years. In contrast, on average, slow progressors would lose 0.8, 2.1, and 4.1 dB MD under the same target IOPs and time frame. When using our tool to quantify the OAG progression dynamics for all 571 patients, we found no statistically significant differences over 5 years between progression for black versus white, male versus female, and CIGTS versus AGIS participants under different target IOPs (P > 0.05 for all). To our knowledge, this is the first clinical decision-making tool that generates personalized forecasts of the trajectory of OAG progression at different target IOP levels. This approach can help clinicians determine appropriate, personalized target IOPs for patients with OAG. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation

    PubMed Central

    Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan

    2017-01-01

    A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (−1.8 and −0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (−2.95 and −3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dBm input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dBm at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dBm at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dBm input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (−48.34, −44.21, −48.34, and −46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (−45.61, −41.57, −45.01, and −45.51 dB, respectively). When five-cycle 20 dBm input power was applied, the second, third, fourth, and fifth harmonic distortions of the HVPA with the power MOSFET linearizer (−41.54, −41.80, −48.86, and −46.27 dB, respectively) were also lower than that of the HVPA without the power MOSFET linearizer (−25.85, −43.56, −49.04, and −49.24 dB, respectively). Therefore, we conclude that the power MOSFET linearizer could reduce gain deviation of the HVPA, thus reducing the echo signal harmonic distortions generated by the high-frequency ultrasonic transducers in pulse-echo instrumentation. PMID:28375165

  14. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    PubMed

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P < 0.001), tests performed after lunch (P < 0.001), and tests performed in the summer or autumn (P < 0.001). The effects of time of day and season appeared to depend on disease stage. Independent of these effects, the percentage of false-positive answers strongly influenced the MD with a 1 dB increase in MD per 10% increase in false-positive answers. Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  15. Dual-wavelength nano-engineered Thulium-doped fiber laser via bending of singlemode-multimode-singlemode fiber structure

    NASA Astrophysics Data System (ADS)

    Zulkifli, A. Z.; Latiff, A. A.; Paul, M. C.; Yasin, M.; Ahmad, H.; Harun, S. W.

    2016-12-01

    In this paper, a dual-wavelength fiber laser (DWFL) using nano-engineered Thulium-doped fiber as a gain medium with a bent singlemode-multimode-singlemode fiber structure (SMS) is demonstrated. The SMS structure is packaged systematically using Cr-39 polymer plates to provide linear bending via applied load. Experimental results have proved that the bent SMS is capable to provide highly effective wavelength filter and wavelengths stabilizer by balancing the net cavity gain between the two wavelengths. The DWFL provides very narrow spacing of 0.9 nm, narrow 3 dB spectral linewidth of ∼0.07 nm and SNR of ∼42 dB. Based on stability test, very small mode hopping is observed at the two wavelengths having deviations of ±0 nm and ±0.04 nm respectively. In conjunction, the DWFL provides very stable relative wavelength spacing with a deviation of ±0.04 nm.

  16. Effects of steam inhalation on voice quality-related acoustic measures.

    PubMed

    Mahalingam, Shenbagavalli; Boominathan, Prakash

    2016-10-01

    To investigate the effects of steam inhalation using a facial steamer on voice quality-related acoustic measures. Prospective outcome research: single-blinded experimental study. Forty-five vocally healthy female subjects ranging in age from 18 to 30 years (Mean age: 22.41 years; standard deviation [SD]: 8.91) participated in the study. Phonation samples were recorded under three different conditions in triplicate: baseline recording, immediately after mouth breathing (dehydration), and immediately after 3 minutes of steam inhalation via the mouth (rehydration). In the initial voice recording (prior to dehydration), mean jitter (0.42 %; SD: 0.07), shimmer (2.20 dB; SD: 0.45), and harmonics-to-noise ratio (HNR) (21.60; SD: 2.41) values were within normal limits. After short-term mouth breathing (dehydration, approximately 10 minutes), the mean jitter (1.57 %; SD: 1.82) and shimmer (4.73 dB; SD: 1.83) were significantly increased (P < 0.05), and HNR (18.64; SD: 3.16) was reduced (P < 0.05). After steam inhalation (rehydration) for 3 minutes, mean jitter (0.48 %; SD: 0.12) and shimmer (2.70 dB; SD: 0.71) showed significant decrease (P < 0.05), and HNR (20.10; SD: 3.69) showed significant increase (P < 0.05). All parameters statistically significantly improved from post dehydration values. The simple procedure of steam inhalation using a facial steamer displayed positive effects on parameters proposed to reflect voice quality. 4. Laryngoscope, 126:2305-2309, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Noise pollution effect in flour factory on workers' hearing in Lamerd City.

    PubMed

    Mohammadizadeh, M; Ahmadi, S H; Sekhavati, E; Ahani-Jegar, K

    2015-01-01

    Introduction: Noise pollution is one of the most important problems in industry that has an effect on the auditory system and other physiological parameters, as well as persons in noise exposure situations. While noise-induced hearing loss is preventable, once acquired, hearing loss is permanent and irreversible. Methodology: In the current study, noise in various sections of Flour Company in Lamerd estimated via the audio recorder, which revealed that the operators' expression remained larger than the state criterion; hence, the perception experiment (audio recorder) was performed on the operators and its outcomes were examined via utilizing SPSS 16 of version. Findings: Overall, Pearson relationship r = 0.453 discovered among job reports and the performance decline between all operators by significant stage p≤0.05. Moreover, T-test applied to examine noise impact on operators included in boisterous rooms (mean more than 85 dB) also average=26. 71 and regular deviation=11.72 got (p≤0.05) that was greater than 25db (as the standard hearing threshold). Conclusion: The outcomes of audio measuring and T-test revealed that the noise corruption has an impact on the hearing of bodies operating in noisy rooms.

  18. Circulating metabolites of strawberry mediate reductions in vascular inflammation and endothelial dysfunction in db/db mice.

    PubMed

    Petersen, Chrissa; Bharat, Divya; Cutler, Brett Ronald; Gholami, Samira; Denetso, Christopher; Mueller, Jennifer Ellen; Cho, Jae Min; Kim, Ji-Seok; Symons, J David; Anandh Babu, Pon Velayutham

    2018-07-15

    Cardiovascular disease is 2-4-fold more prevalent in patients with diabetes. Human studies support the cardiovascular benefits of strawberry consumption but the effects of strawberry on diabetic vasculature are unknown. We tested the hypothesis that dietary strawberry supplementation attenuates vascular inflammation and dysfunction in diabetic mice. Seven-week-old diabetic db/db mice that consumed standard diet (db/db) or diet supplemented with 2.35% freeze-dried strawberry (db/db + SB) for ten weeks were compared to non-diabetic control mice (db/+). Indices of vascular inflammation and dysfunction were measured. Endothelial cells (ECs) were isolated from the vasculature to determine the influence of strawberry on them. The effect of metabolites of strawberry on endothelial inflammation was determined by incubating mouse aortic ECs (MAECs) with ±5% serum, obtained from strawberry fed mice (metabolites serum) or standard diet fed mice (control serum) ± 25 mM glucose and 100 μM palmitate. db/db mice exhibited an increased monocyte binding to vessel, elevated blood pressure, and reduced endothelial-dependent vasorelaxation compared with db/+ mice but each defect was attenuated in db/db + SB mice. The elevation of inflammatory molecules, NOX2 and inhibitor-κB kinase observed in ECs from db/db vs. db/+ mice was suppressed in db/db + SB mice. Glucose and palmitate increased endothelial inflammation in MAECs but were normalized by co-incubation with metabolites serum. Dietary supplementation of strawberry attenuates indices of vascular inflammation and dysfunction in diabetic db/db mice. The effect of strawberry on vasculature is endothelial-dependent and possibly mediated through their circulating metabolites. Strawberry might complement conventional therapies to improve vascular complications in diabetics. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Multi-year slant path rain fade statistics at 28.56 and 19.04 GHz for Wallops Island, Virginia

    NASA Technical Reports Server (NTRS)

    Goldhirsh, J.

    1979-01-01

    Multiyear rain fade statistics at 28.56 GHz and 19.04 GHz were compiled for the region of Wallops Island, Virginia covering the time periods, 1 April 1977 through 31 March 1978, and 1 September 1978 through 31 August 1979. The 28.56 GHz attenuations were derived by monitoring the beacon signals from the COMSTAR geosynchronous satellite, D sub 2 during the first year, and satellite, D sub 3, during the second year. Although 19.04 GHz beacons exist aboard these satellites, statistics at this frequency were predicted using the 28 GHz fade data, the measured rain rate distribution, and effective path length concepts. The prediction method used was tested against radar derived fade distributions and excellent comparisons were noted. For example, the rms deviations between the predicted and test distributions were less than or equal to 0.2dB or 4% at 19.04 GHz. The average ratio between the 28.56 GHz and 19.04 GHz fades were also derived for equal percentages of time resulting in a factor of 2.1 with a .05 standard deviation.

  20. [Simultaneous determination of 15 polycyclic aromatic hydrocarbons in cigarette filter by gas chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Xiaotao; Zhang, Li; Ruan, Yibin; Wang, Weiwei; Ji, Houwei; Wan, Qiang; Lin, Fucheng; Liu, Jian

    2017-10-08

    A method for the simultaneous determination of 15 polycyclic aromatic hydrocarbons in cigarette filter was developed by isotope internal standard combined with gas chromatography-tandem mass spectrometry. The cigarette filters were extracted with dichloromethane, and the extract was filtered with 0.22 μm organic phase membrane. The samples were isolated by DB-5MS column (30 m×0.25 mm, 0.25 μm) and detected using multiple reaction monitoring mode of electron impact source under positive ion mode. The linearities of the 15 polycyclic aromatic hydrocarbons (acenapthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, ben[ a ]anthracene, chrysene, benzo[ b ]fluoranthene, benzo[ k ]fluoranthene, benzo[ a ]pyrene, dibenzo[ a,h ]anthracene, benzo[ g,h,i ]perylene and indeno[1,2,3- c,d ]pyrene) were good, and the correlation coefficients ( R 2 ) ranged from 0.9914 to 0.9999. The average recoveries of the 15 polycyclic aromatic hydrocarbons were 81.6%-109.6% at low, middle and high spiked levels, and the relative standard deviations were less than 16%, except that the relative standard deviation of fluorene at the low spiked level was 19.2%. The limits of detection of the 15 polycyclic aromatic hydrocarbons were 0.02 to 0.24 ng/filter, and the limits of quantification were 0.04 to 0.80 ng/filter. The method is simple, rapid, accurate, sensitive and reproducible. It is suitable for the quantitative analysis of the 15 polycyclic aromatic hydrocarbons in cigarette filters.

  1. Design and analysis of a low-loss linear analog phase modulator for deep space spacecraft X-band transponder applications

    NASA Technical Reports Server (NTRS)

    Mysoor, N. R.; Mueller, R. O.

    1991-01-01

    This article summarizes the design concepts, analyses, and development of an X-band (8145 MHz) transponder low-loss linear phase modulator for deep space spacecraft applications. A single-section breadboard circulator-coupled reflection phase modulator has been analyzed, fabricated, and evaluated. A linear phase deviation of 92 deg with a linearity tolerance of +/- 8 percent was measured for this modulator from 8257 MHz to 8634 MHz over the temperature range -20 to 75 C. The measured insertion loss and the static delay variation with temperature were 2 +/- 0.3 dB and 0.16 psec/ C, respectively. Based on this design, cascaded sections have been modeled, and simulations were performed to provide an X-band deep space transponder (DST) phase modulator with +/- 2.5 radians (+/- 143 deg) of peak phase deviation to accommodate downlink signal modulation with composite telemetry data and ranging, with a deviation linearity tolerance of +/- 8 percent and insertion loss of less than 10 +/- 0.5 dB. A two-section phase modulator using constant gamma hyperabrupt varactors and an efficient modulator driver circuit was breadboarded. The measured results satisfy the DST phase-modulator requirements and show excellent agreement with the predicted results.

  2. Iterative demodulation and decoding of coded non-square QAM

    NASA Technical Reports Server (NTRS)

    Li, L.; Divsalar, D.; Dolinar, S.

    2003-01-01

    Simulation results show that, with iterative demodulation and decoding, coded NS-8QAM performs 0.5 dB better than standard 8QAM and 0.7 dB better than 8PSK at BER= 10(sup -5), when the FEC code is the (15, 11) Hamming code concatenated with a rate-1 accumulator code, while coded NS-32QAM performs 0.25 dB better than standard 32QAM.

  3. Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter.

    PubMed

    Crescenti, Remo A; Bamber, Jeffrey C; Partridge, Mike; Bush, Nigel L; Webb, Steve

    2007-11-21

    Research on polymer-gel dosimetry has been driven by the need for three-dimensional dosimetry, and because alternative dosimeters are unsatisfactory or too slow for that task. Magnetic resonance tomography is currently the most well-developed technique for determining radiation-induced changes in polymer structure, but quick low-cost alternatives remain of significant interest. In previous work, ultrasound attenuation and speed of sound were found to change as a function of absorbed radiation dose in polymer-gel dosimeters, although the investigations were restricted to one ultrasound frequency. Here, the ultrasound attenuation coefficient mu in one polymer gel (MAGIC) was investigated as a function of radiation dose D and as a function of ultrasonic frequency f in a frequency range relevant for imaging dose distributions. The nonlinearity of the frequency dependence was characterized, fitting a power-law model mu = af(b); the fitting parameters were examined for potential use as additional dose readout parameters. In the observed relationship between the attenuation coefficient and dose, the slopes in a quasi-linear dose range from 0 to 30 Gy were found to vary with the gel batch but lie between 0.0222 and 0.0348 dB cm(-1) Gy(-1) at 2.3 MHz, between 0.0447 and 0.0608 dB cm(-1) Gy(-1) at 4.1 MHz and between 0.0663 and 0.0880 dB cm(-1) Gy(-1) at 6.0 MHz. The mean standard deviation of the slope for all samples and frequencies was 15.8%. The slope was greater at higher frequencies, but so were the intra-batch fluctuations and intra-sample standard deviations. Further investigations are required to overcome the observed variability, which was largely associated with the sample preparation technique, before it can be determined whether any frequency is superior to others in terms of accuracy and precision in dose determination. Nevertheless, lower frequencies will allow measurements through larger samples. The fit parameter a of the frequency dependence, describing the attenuation coefficient at 1 MHz, was found to be dose dependent, which is consistent with our expectations, as polymerization is known to be associated with increased absorption of ultrasound. No significant dose dependence was found for the fit parameter b, which describes the nonlinearity with frequency. This is consistent with the increased absorption being due to the introduction of new relaxation processes with characteristic frequencies similar to those of existing processes. The data presented here will help with optimizing the design of future 3D dose-imaging systems using ultrasound methods.

  4. Characterizing multi-scale self-similar behavior and non-statistical properties of fluctuations in financial time series

    NASA Astrophysics Data System (ADS)

    Ghosh, Sayantan; Manimaran, P.; Panigrahi, Prasanta K.

    2011-11-01

    We make use of wavelet transform to study the multi-scale, self-similar behavior and deviations thereof, in the stock prices of large companies, belonging to different economic sectors. The stock market returns exhibit multi-fractal characteristics, with some of the companies showing deviations at small and large scales. The fact that, the wavelets belonging to the Daubechies’ (Db) basis enables one to isolate local polynomial trends of different degrees, plays the key role in isolating fluctuations at different scales. One of the primary motivations of this work is to study the emergence of the k-3 behavior [X. Gabaix, P. Gopikrishnan, V. Plerou, H. Stanley, A theory of power law distributions in financial market fluctuations, Nature 423 (2003) 267-270] of the fluctuations starting with high frequency fluctuations. We make use of Db4 and Db6 basis sets to respectively isolate local linear and quadratic trends at different scales in order to study the statistical characteristics of these financial time series. The fluctuations reveal fat tail non-Gaussian behavior, unstable periodic modulations, at finer scales, from which the characteristic k-3 power law behavior emerges at sufficiently large scales. We further identify stable periodic behavior through the continuous Morlet wavelet.

  5. AHCODA-DB: a data repository with web-based mining tools for the analysis of automated high-content mouse phenomics data.

    PubMed

    Koopmans, Bastijn; Smit, August B; Verhage, Matthijs; Loos, Maarten

    2017-04-04

    Systematic, standardized and in-depth phenotyping and data analyses of rodent behaviour empowers gene-function studies, drug testing and therapy design. However, no data repositories are currently available for standardized quality control, data analysis and mining at the resolution of individual mice. Here, we present AHCODA-DB, a public data repository with standardized quality control and exclusion criteria aimed to enhance robustness of data, enabled with web-based mining tools for the analysis of individually and group-wise collected mouse phenotypic data. AHCODA-DB allows monitoring in vivo effects of compounds collected from conventional behavioural tests and from automated home-cage experiments assessing spontaneous behaviour, anxiety and cognition without human interference. AHCODA-DB includes such data from mutant mice (transgenics, knock-out, knock-in), (recombinant) inbred strains, and compound effects in wildtype mice and disease models. AHCODA-DB provides real time statistical analyses with single mouse resolution and versatile suite of data presentation tools. On March 9th, 2017 AHCODA-DB contained 650 k data points on 2419 parameters from 1563 mice. AHCODA-DB provides users with tools to systematically explore mouse behavioural data, both with positive and negative outcome, published and unpublished, across time and experiments with single mouse resolution. The standardized (automated) experimental settings and the large current dataset (1563 mice) in AHCODA-DB provide a unique framework for the interpretation of behavioural data and drug effects. The use of common ontologies allows data export to other databases such as the Mouse Phenome Database. Unbiased presentation of positive and negative data obtained under the highly standardized screening conditions increase cost efficiency of publicly funded mouse screening projects and help to reach consensus conclusions on drug responses and mouse behavioural phenotypes. The website is publicly accessible through https://public.sylics.com and can be viewed in every recent version of all commonly used browsers.

  6. Sensitivity enhancement of fiber loop cavity ring-down pressure sensor.

    PubMed

    Jiang, Yajun; Yang, Dexing; Tang, Daqing; Zhao, Jianlin

    2009-11-10

    We present a theoretical and experimental study on sensitivity enhancement of a fiber-loop cavity ring-down pressure sensor. The cladding of the sensing fiber is etched in hydrofluoric acid solution to enhance its sensitivity. The experimental results demonstrate that the pressure applied on the sensing fiber is linearly proportional to the difference between the reciprocals of the ring-down time with and without pressure, and the relative sensitivity exponentially increases with decreasing the cladding diameter. When the sensing fiber is etched to 41.15 microm, its sensitivity is about 36 times that of nonetched fiber in the range of 0 to 32.5 MPa. The measured relative standard deviation of the ring-down time is about 0.15% and, correspondingly, the least detectable loss is about 0.00069 dB.

  7. Frequency modulation television analysis: Distortion analysis

    NASA Technical Reports Server (NTRS)

    Hodge, W. H.; Wong, W. H.

    1973-01-01

    Computer simulation is used to calculate the time-domain waveform of standard T-pulse-and-bar test signal distorted in passing through an FM television system. The simulator includes flat or preemphasized systems and requires specification of the RF predetection filter characteristics. The predetection filters are modeled with frequency-symmetric Chebyshev (0.1-db ripple) and Butterworth filters. The computer was used to calculate distorted output signals for sixty-four different specified systems, and the output waveforms are plotted for all sixty-four. Comparison of the plotted graphs indicates that a Chebyshev predetection filter of four poles causes slightly more signal distortion than a corresponding Butterworth filter and the signal distortion increases as the number of poles increases. An increase in the peak deviation also increases signal distortion. Distortion also increases with the addition of preemphasis.

  8. High-frequency (8 to 16 kHz) reference thresholds and intrasubject threshold variability relative to ototoxicity criteria using a Sennheiser HDA 200 earphone.

    PubMed

    Frank, T

    2001-04-01

    The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.

  9. Bilateral hearing loss is associated with decreased nonverbal intelligence in US children aged 6 to 16 years.

    PubMed

    Emmett, Susan D; Francis, Howard W

    2014-09-01

    To evaluate the association between hearing loss and nonverbal intelligence in US children. The Third National Health and Nutrition Examination Survey (NHANES III) is a cross-sectional survey (1988-1994) that used complex multistage sampling design to produce nationally representative demographic and examination data. A total of 4,823 children ages 6 to 16 years completed audiometric evaluation and cognitive testing during NHANES III. Hearing loss was defined as low-frequency pure-tone average (PTA) >25 dB (0.5, 1, 2 kHz) or high-frequency PTA >25 dB (3, 4, 6, 8 kHz) and was designated as unilateral or bilateral. Nonverbal intelligence was measured using the Wechsler Intelligence Scale for Children-Revised block design subtest. Low nonverbal intelligence was defined as a standardized score <4, two standard deviations below the standardized mean of 10. Mean nonverbal intelligence scores differed between children with normal hearing (9.59) and children with bilateral (6.87; P = .02) but not unilateral (9.12; P = .42) hearing loss. Non-Hispanic black race/ethnicity and family income <$20,000 were associated with 3.92 and 1.67 times higher odds of low nonverbal intelligence, respectively (odds ratio [OR]: 3.92; P < .001; OR: 1.67; P = .02). Bilateral hearing loss was independently associated with 5.77 times increased odds of low nonverbal intelligence compared to normal hearing children (OR: 5.77; P = .02). Unilateral hearing loss was not associated with higher odds of low nonverbal intelligence (OR: 0.73; P = .40). Bilateral but not unilateral hearing loss is associated with decreased nonverbal intelligence in US children. Longitudinal studies are urgently needed to better understand these associations and their potential impact on future opportunities. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Bilateral Hearing Loss is Associated with Decreased Nonverbal Intelligence in US Children Ages 6 to 16 Years

    PubMed Central

    Emmett, Susan D.; Francis, Howard W.

    2017-01-01

    Objectives To evaluate the association between hearing loss and nonverbal intelligence in US children. Study Design The Third National Health and Nutrition Examination Survey (NHANES III) is a cross-sectional survey (1988–1994) that used complex multistage sampling design to produce nationally representative demographic and examination data. Methods A total of 4823 children ages 6–16 years completed audiometric evaluation and cognitive testing during NHANES III. Hearing loss was defined as low frequency pure tone average (PTA)>25 decibels (dB) (0.5,1,2 kHz) or high frequency PTA>25dB (3,4,6,8 kHz) and was designated as unilateral or bilateral. Nonverbal intelligence was measured using the Wechsler Intelligence Scale for Children-Revised block design subtest. Low nonverbal intelligence was defined as a standardized score <4, two standard deviations below the standardized mean of 10. Results Mean nonverbal intelligence scores differed between children with normal hearing (9.59) and children with bilateral (6.87; p=0.02) but not unilateral (9.12; p=0.42) hearing loss. Non-Hispanic black race/ethnicity and family income<$20,000 were associated with 3.92 and 1.67 times higher odds of low nonverbal intelligence, respectively (OR 3.92; p<0.001; OR 1.67; p=0.02). Bilateral hearing loss was independently associated with 5.77 times increased odds of low nonverbal intelligence compared to normal hearing children (OR 5.77; p=0.02). Unilateral hearing loss was not associated with higher odds of low nonverbal intelligence (OR 0.73; p=0.40). Conclusion Bilateral but not unilateral hearing loss is associated with decreased nonverbal intelligence in US children. Longitudinal studies are urgently needed to better understand these associations and their potential impact on future opportunities. PMID:24913183

  11. Ultrashort broadband polarization beam splitter based on a combined hybrid plasmonic waveguide.

    PubMed

    Chang, Ken-Wei; Huang, Chia-Chien

    2016-01-20

    We propose an ultracompact broadband polarization beam splitter (PBS) based on a combined hybrid plasmonic waveguide (HPW). The proposed PBS separates transverse-electric (TE) and transverse-magnetic (TM) modes using a bent lower HPW with vertical nanoscale gaps and a straight upper HPW with a horizontal nanoscale gap, respectively, without relying on an additional coupling region. This design considerably reduces the length of the PBS to the submicron scale (920 nm, the shortest PBS reported to date) while offering polarization extinction ratios (PERs) of ~19 dB (~18 dB) and insertion losses (ILs) of ~0.6 dB (~0.3 dB) for the TE (TM) mode over an extremely broad band of 400 nm (from λ = 1300 nm to 1700 nm, covering entirely second and third telecom windows). The length of the designed PBS can be reduced further to 620 nm while still offering PERs of 15 dB, realizing a densely photonic integrated circuit. Considering the fabrication tolerance, the designed PBS allows for large geometrical deviations of ± 20 nm while restricting PER variations to within 1 dB, except for those in the nanoscale gaps smaller than 10nm. Additionally, we also address the input and ouput coupling efficiencies of the proposed PBS.

  12. The idiopathic intracranial hypertension treatment trial: clinical profile at baseline.

    PubMed

    Wall, Michael; Kupersmith, Mark J; Kieburtz, Karl D; Corbett, James J; Feldon, Steven E; Friedman, Deborah I; Katz, David M; Keltner, John L; Schron, Eleanor B; McDermott, Michael P

    2014-06-01

    To our knowledge, there are no large prospective cohorts of untreated patients with idiopathic intracranial hypertension (IIH) to characterize the disease. To report the baseline clinical and laboratory features of patients enrolled in the Idiopathic Intracranial Hypertension Treatment Trial. We collected data at baseline from questionnaires, examinations, automated perimetry, and fundus photography grading. Patients (n = 165) were enrolled from March 17, 2010, to November 27, 2012, at 38 academic and private practice sites in North America. All participants met the modified Dandy criteria for IIH and had a perimetric mean deviation between -2 dB and -7 dB. All but 4 participants were women. Baseline and laboratory characteristics. The mean (SD) age of our patients was 29.0 (7.4) years and 4 (2.4%) were men. The average (SD) body mass index (calculated as weight in kilograms divided by height in meters squared) was 39.9 (8.3). Headache was the most common symptom (84%). Transient visual obscurations occurred in 68% of patients, back pain in 53%, and pulse synchronous tinnitus in 52%. Only 32% reported visual loss. The average (SD) perimetric mean deviation in the worst eye was -3.5 (1.1) dB, (range, -2.0 to -6.4 dB) and in the best eye was -2.3 (1.1) dB (range, -5.2 to 0.8 dB). A partial arcuate visual field defect with an enlarged blind spot was the most common perimetric finding. Visual acuity was 85 letters or better (20/20) in 71% of the worst eyes and 77% of the best eyes. Quality of life measures, including the National Eye Institute Visual Function Questionnaire-25 and the Short Form-36 physical and mental health summary scales, were lower compared with population norms. The Idiopathic Intracranial Hypertension Treatment Trial represents the largest prospectively analyzed cohort of untreated patients with IIH. Our data show that IIH is almost exclusively a disease of obese young women. Patients with IIH with mild visual loss have typical symptoms, may have mild acuity loss, and have visual field defects, with predominantly arcuate loss and enlarged blind spots that require formal perimetry for detection. clinicaltrials.gov Identifier: NCT01003639.

  13. Design and performance of clock-recovery GaAs ICs for high-speed optical communication systems

    NASA Astrophysics Data System (ADS)

    Imai, Yuhki; Sano, Eiichi; Nakamura, Makoto; Ishihara, Noboru; Kikuchi, Hiroyuki; Ono, Takashi

    1993-05-01

    Design and performance of clock-recovery GaAs ICs are presented. Four kinds of ICs were developed: a limiting amplifier, a tuning amplifier, a rectifier, and a differentiator. The cascaded limiting amplifier together with a tuning amplifier achieved a 58-dB gain and a 10-degree phase deviation with 20-dB input dynamic range at 10 GHz. A clock-recovery circuit successfully extracts a low-jitter 10-GHz clock signal of 1-dBm constant power from 10-Gb/s NRZ pseudorandom bit streams using a pulse pattern generator.

  14. The relationship between better-eye and integrated visual field mean deviation and visual disability.

    PubMed

    Arora, Karun S; Boland, Michael V; Friedman, David S; Jefferys, Joan L; West, Sheila K; Ramulu, Pradeep Y

    2013-12-01

    To determine the extent of difference between better-eye visual field (VF) mean deviation (MD) and integrated VF (IVF) MD among Salisbury Eye Evaluation (SEE) subjects and a larger group of glaucoma clinic subjects and to assess how those measures relate to objective and subjective measures of ability/performance in SEE subjects. Retrospective analysis of population- and clinic-based samples of adults. A total of 490 SEE and 7053 glaucoma clinic subjects with VF loss (MD ≤-3 decibels [dB] in at least 1 eye). Visual field testing was performed in each eye, and IVF MD was calculated. Differences between better-eye and IVF MD were calculated for SEE and clinic-based subjects. In SEE subjects with VF loss, models were constructed to compare the relative impact of better-eye and IVF MD on driving habits, mobility, self-reported vision-related function, and reading speed. Difference between better-eye and IVF MD and relationship of better-eye and IVF MD with performance measures. The median difference between better-eye and IVF MD was 0.41 dB (interquartile range [IQR], -0.21 to 1.04 dB) and 0.72 dB (IQR, 0.04-1.45 dB) for SEE subjects and clinic-based patients with glaucoma, respectively, with differences of ≥ 2 dB between the 2 MDs observed in 9% and 18% of the groups, respectively. Among SEE subjects with VF loss, both MDs demonstrated similar associations with multiple ability and performance metrics as judged by the presence/absence of a statistically significant association between the MD and the metric, the magnitude of observed associations (odds ratios, rate ratios, or regression coefficients associated with 5-dB decrements in MD), and the extent of variability in the metric explained by the model (R(2)). Similar associations of similar magnitude also were noted for the subgroup of subjects with glaucoma and subjects in whom better-eye and IVF MD differed by ≥ 2 dB. The IVF MD rarely differs from better-eye MD, and similar associations between VF loss and visual disability are obtained using either MD. Unlike better-eye MD, IVF measurements require extra software/calculation. As such, information from studies using better-eye MD can be more easily integrated into clinical decision-making, making better-eye MD a robust and meaningful method for reporting VF loss severity. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  15. Temporary Hearing Threshold Shift in Healthy Volunteers with Hearing Protection Caused by Acoustic Noise Exposure during 3-T Multisequence MR Neuroimaging.

    PubMed

    Jin, Chao; Li, Huan; Li, Xianjun; Wang, Miaomiao; Liu, Congcong; Guo, Jianxin; Yang, Jian

    2018-02-01

    Purpose To determine whether a single 51-minute exposure to acoustic noise during 3-T multisequence magnetic resonance (MR) neuroimaging could affect the hearing threshold of healthy adults with earplugs and sponge mats as hearing protection. Materials and Methods With earplugs and motion-refraining sponge mats as hearing protection, 26 healthy young adults underwent 3-T MR neuroimaging imaging that included T1-weighted three-dimensional gradient-echo sequence, T2-weighted fast spin-echo sequence, diffusion-tensor imaging, diffusion-kurtosis imaging, T2*-weighted three-dimensional multiecho gradient-echo sequence, and blood oxygen level-dependent imaging. Automated auditory brainstem response (ABR) was used to measure the hearing thresholds within 24 hours before, within 20 minutes after, and 25 days after the MR examination. One-way repeated-measure analysis of variance with Bonferroni adjustment was used to compare automated ABR results among the three tests and partial η 2 (η p 2 ) was reported as a measure of effect size. Results Automated ABR results showed significantly increased mean threshold shift of 5.0 dB ± 8.1 (standard deviation) (left ear: 4.8 dB ± 9.2 [95% confidence interval: 1.09, 8.53], η p 2 = 0.221, P = .013; right ear: 5.2 dB ± 6.9 [95% confidence interval: 2.36, 8.02], η p 2 = 0.364, P = .001) immediately after the MR examination compared with the baseline study. This shift is below the temporary threshold shift of 40-50 dB that is associated with cochlea nerve changes. Automated ABR obtained at day 25 after MR imaging showed no significant differences from baseline (left ear: -2.3 dB ± 8.6 [95% confidence interval: -5.79, 1.78], η p 2 = 0.069, P = .185; right ear: 0.4 dB ± 7.3 [95% confidence interval: -3.35, 2.58], η p 2 = 0.003, P = .791). Conclusion A 3-T MR neuroimaging examination with the acoustic noise at equivalent sound pressure level of 103.5-111.3 dBA lasting 51 minutes can cause temporary hearing threshold shift in healthy volunteers with hearing protection. © RSNA, 2017.

  16. Ship noise extends to frequencies used for echolocation by endangered killer whales.

    PubMed

    Veirs, Scott; Veirs, Val; Wood, Jason D

    2016-01-01

    Combining calibrated hydrophone measurements with vessel location data from the Automatic Identification System, we estimate underwater sound pressure levels for 1,582 unique ships that transited the core critical habitat of the endangered Southern Resident killer whales during 28 months between March, 2011, and October, 2013. Median received spectrum levels of noise from 2,809 isolated transits are elevated relative to median background levels not only at low frequencies (20-30 dB re 1 µPa(2)/Hz from 100 to 1,000 Hz), but also at high frequencies (5-13 dB from 10,000 to 96,000 Hz). Thus, noise received from ships at ranges less than 3 km extends to frequencies used by odontocetes. Broadband received levels (11.5-40,000 Hz) near the shoreline in Haro Strait (WA, USA) for the entire ship population were 110 ± 7 dB re 1 µPa on average. Assuming near-spherical spreading based on a transmission loss experiment we compute mean broadband source levels for the ship population of 173 ± 7 dB re 1 µPa 1 m without accounting for frequency-dependent absorption. Mean ship speed was 7.3 ± 2.0 m/s (14.1 ± 3.9 knots). Most ship classes show a linear relationship between source level and speed with a slope near +2 dB per m/s (+1 dB/knot). Spectrum, 1/12-octave, and 1/3-octave source levels for the whole population have median values that are comparable to previous measurements and models at most frequencies, but for select studies may be relatively low below 200 Hz and high above 20,000 Hz. Median source spectrum levels peak near 50 Hz for all 12 ship classes, have a maximum of 159 dB re 1 µPa(2)/Hz @ 1 m for container ships, and vary between classes. Below 200 Hz, the class-specific median spectrum levels bifurcate with large commercial ships grouping as higher power noise sources. Within all ship classes spectrum levels vary more at low frequencies than at high frequencies, and the degree of variability is almost halved for classes that have smaller speed standard deviations. This is the first study to present source spectra for populations of different ship classes operating in coastal habitats, including at higher frequencies used by killer whales for both communication and echolocation.

  17. Glaucoma progression detection with frequency doubling technology (FDT) compared to standard automated perimetry (SAP) in the Groningen Longitudinal Glaucoma Study.

    PubMed

    Wesselink, Christiaan; Jansonius, Nomdo M

    2017-09-01

    To determine the usefulness of frequency doubling perimetry (FDT) for progression detection in glaucoma, compared to standard automated perimetry (SAP). Data were used from 150 eyes of 150 glaucoma patients from the Groningen Longitudinal Glaucoma Study. After baseline, SAP was performed approximately yearly; FDT every other year. First and last visit had to contain both tests. Using linear regression, progression velocities were calculated for SAP (Humphrey Field Analyzer) mean deviation (MD) and FDT MD and the number of test locations with a total deviation probability below p < 0.01 (TD). Progression velocity tertiles were determined and eyes were classified as slowly, intermediately, or fast progressing for both techniques. Comparison between SAP and FDT classifications were made using a Mantel Haenszel chi-square test. Longitudinal signal-to-noise ratios (LSNRs) were calculated, per patient and per technique, defined as progression velocity divided by the standard deviation of the residuals. Mean (SD) follow-up was 6.4 (1.7) years; median (interquartile range [IQR]) baseline SAP MD -6.6 (-14.2 to -3.6) dB. On average 8.2 and 4.5 tests were performed for SAP and FDT, respectively. Median (IQR) MD slope was -0.16 (-0.46 to +0.02) dB/year for SAP and -0.05 (-0.39 to +0.17) dB/year for FDT. Mantel Haenszel chi-squares of SAP MD vs FDT MD and TD were 12.5 (p < 0.001) and 15.8 (p < 0.001), respectively. LSNRs for SAP MD (median -0.17 yr -1 ) were better than those for FDT MD (-0.04 yr -1 ; p = 0.010). FDT may be a useful technique for monitoring glaucoma progression in patients who cannot perform SAP reliably. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  18. Suspended sand transport in surf zones

    NASA Astrophysics Data System (ADS)

    Kobayashi, Nobuhisa; Zhao, Haoyu; Tega, Yukiko

    2005-12-01

    Three tests were conducted in a wave flume to investigate time-averaged suspended sediment transport processes under irregular breaking waves on equilibrium beaches consisting of fine sand. Free surface elevations were measured at ten locations for each test. Velocities and concentrations were measured in the vicinity of the bottom at 94 elevations along 17 vertical lines. The relations among the three turbulent velocity variances are found to be similar to those for the boundary layer flow. The vertical variation of the mean velocity, which causes offshore transport, is fitted by a parabolic profile fairly well. The vertical variation of the mean concentration ? is fitted by the exponential and power-form distributions equally well. The ratio between the concentration standard deviation σC and the mean ? varies little vertically. The correlation coefficient γUC between the horizontal velocity and concentration, which results in onshore transport, is of the order of 0.1 and decreases upward linearly. The offshore and onshore transport rates of suspended sediment are estimated and expressed in terms of the suspended sediment volume ? per unit area. A time-averaged numerical model is developed to predict ? as well as the mean and standard deviation of the free surface elevation and horizontal velocity. The bottom slope effect on the wave energy dissipation rate DB due to wave breaking is included in the model. The computation can be made well above the still water shoreline with no numerical difficulty. Reflected waves from the shoreline are estimated from the wave energy flux remaining at the shoreline. The numerical model is in agreement with the statistical data except that the undertow current is difficult to predict accurately. The measured turbulent velocities are found to be more related to the turbulent velocity estimated from the energy dissipation rate Df due to bottom friction. The suspended sediment volume ? expressed in terms of DB and Df can be predicted only within a factor of about 2. The roller effect represented by the roller volume flux does not necessarily improve the agreement for the three tests.

  19. Beta-zone parapapillary atrophy and multifocal visual evoked potentials in eyes with glaucomatous optic neuropathy

    PubMed Central

    Ketner, Scott; Teng, Christopher C.; Ehrlich, Joshua R.; Raza, Ali S.; Liebmann, Jeffrey M.; Ritch, Robert; Hood, Donald C.

    2015-01-01

    We investigated changes in multifocal visual evoked potential (mfVEP) responses due to beta-zone parapapillary atrophy (βPPA). Patients with glaucomatous optic neuropathy (GON) with or without standard achromatic perimetry (SAP) abnormalities were referred for mfVEP testing during a 2-year period. Eyes with good quality optic disc stereophotographs and reliable SAP results were included. The mfVEP monocular mean latency delays (ms) and amplitudes (SNR) were analyzed. Age, SAP mean deviation (MD), pattern standard deviation (PSD), and spherical equivalent (SE) were analyzed in the multivariate model. Generalized estimated equations were used for comparisons between groups after adjusting for inter-eye associations. Of 394 eyes of 200 patients, 223 (57%) had βPPA. The βPPA eyes were older (59.6 ± 13.7 vs. 56.5 ± 13.7 year, P = 0.02), more myopic (−4.0 ± 3.5 vs. −1.3 ± 3.5 D, P < 0.01), and had poorer SAP scores (MD: −4.9 ± 5.2 vs. −2.6 ± 5.2 dB, P < 0.01; PSD: 4.3 ± 2.9 vs. 2.5 ± 3.0 dB, P < 0.01). By univariate analysis, mean latencies were longer in βPPA eyes (6.1 ± 5.3 vs. 4.0 ± 5.5 ms, P < 0.01). After adjusting for differences in SE, age, and SAP MD, there was no significant difference between the two groups (P = 0.09). βPPA eyes had lower amplitude log SNR (0.49 ± 0.16 vs. 0.56 ± 0.15, P < 0.01), which lost significance (P = 0.51) after adjusting for MD and PSD. Although eyes with βPPA had significantly lower amplitudes and prolonged latencies than eyes without βPPA, these differences were attributable to differences in SAP severity, age, and refractive error. Thus, βPPA does not appear to be an independent factor affecting mfVEP responses in eyes with GON. PMID:21735265

  20. Assessment of ocular hypotensive effect and safety 12 months after changing from an unfixed combination to a latanoprost 0.005% + timolol maleate 0.5% fixed combination.

    PubMed

    Inoue, Kenji; Okayama, Ryoko; Higa, Risako; Wakakura, Masato; Tomita, Goji

    2012-01-01

    Latanoprost 0.005% + timolol maleate 0.5% combined eyedrops were recently made available in Japan. We prospectively investigated the intraocular pressure (IOP)-lowering effect, visual preservation effect, and adverse reactions of a one-year administration of this fixed combination. The subjects included 162 eyes from 162 patients diagnosed with either primary open-angle glaucoma or ocular hypertension and using an unfixed combination of latanoprost 0.005% and timolol maleate 0.5%. The unfixed combination was discontinued and replaced with the latanoprost 0.005% + timolol maleate 0.5% fixed combination with no washout period. IOP was measured before (baseline) and 3, 6, 9, and 12 months after the change. The mean deviation value of Humphrey field analysis was compared. Adverse reactions were examined at every follow-up. No significant differences were found between mean IOP values obtained at baseline (mean ± standard deviation, 15.2 ± 3.3 mmHg) 3 months (15.1 ± 3.2 mmHg), 6 months (15.3 ± 3.1 mmHg), 9 months (15.3 ± 3.1 mmHg), and 12 months (15.1 ± 3.2 mmHg) after the change from the unfixed to the fixed combination of eyedrops (P = 0.212). In addition, no significant differences were observed between mean deviation values obtained at baseline (-9.11 ± 6.94 dB) and 12 months (-10.08 ± 7.24 dB) after the change (P = 0.114). Thirty-one patients discontinued the fixed combination within 12 months of replacement, due to an insufficient IOP decrease (20 patients, 12.3%) and adverse reactions (11 patients, 6.8%). Following replacement of two eyedrop medications (latanoprost 0.005% and timolol maleate 0.5%) by one fixed combination (latanoprost 0.005% + timolol maleate 0.5%), IOP and visual field were preserved. However, 20% of the patients discontinued the new treatment because of an insufficient IOP decrease and complaints of adverse reactions.

  1. Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.

    PubMed

    Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan

    2016-12-01

    Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.

  2. Acoustic characteristics of modern Greek Orthodox Church music.

    PubMed

    Delviniotis, Dimitrios S

    2013-09-01

    Some acoustic characteristics of the two types of vocal music of the Greek Orthodox Church Music, the Byzantine chant (BC) and ecclesiastical speech (ES), are studied in relation to the common Greek speech and the Western opera. Vocal samples were obtained, and their acoustic parameters of sound pressure level (SPL), fundamental frequency (F0), and the long-time average spectrum (LTAS) characteristics were analyzed. Twenty chanters, including two chanters-singers of opera, sang (BC) and read (ES) the same hymn of Byzantine music (BM), the two opera singers sang the same aria of opera, and common speech samples were obtained, and all audio were analyzed. The distribution of SPL values showed that the BC and ES have higher SPL by 9 and 12 dB, respectively, than common speech. The average F0 in ES tends to be lower than the common speech, and the smallest standard deviation (SD) of F0 values characterizes its monotonicity. The tone-scale intervals of BC are close enough to the currently accepted theory with SD equal to 0.24 semitones. The rate and extent of vibrato, which is rare in BC, equals 4.1 Hz and 0.6 semitones, respectively. The average LTAS slope is greatest in BC (+4.5 dB) but smaller than in opera (+5.7 dB). In both BC and ES, instead of a singer's formant appearing in an opera voice, a speaker's formant (SPF) was observed around 3300 Hz, with relative levels of +6.3 and +4.6 dB, respectively. The two vocal types of BM, BC, and ES differ both to each other and common Greek speech and opera style regarding SPL, the mean and SD of F0, the LTAS slope, and the relative level of SPF. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  3. Practical landmarks for visual field disability in glaucoma.

    PubMed

    Saunders, Luke J; Russell, Richard A; Crabb, David P

    2012-09-01

    To assess whether mean deviation (MD) from automated perimetry is related to the visual field (VF) component for legal fitness to drive (LFTD) in glaucoma patients. Monocular 24-2 VFs of 2604 patients with bilateral VF damage were retrospectively investigated. Integrated visual fields were calculated and used as a surrogate to assess LFTD according to current UK driving licence criteria. The better eye MD (BEMD), worse eye MD (WEMD) and a measure utilising MD of both eyes were compared, to assess respective diagnostic capabilities to predict LFTD (using the integrated visual field surrogate test as the gold standard) and a 'Probability of Failure' (PoF) for various defect levels was calculated. BEMD appears to be a good predictor of the VF component for a patient's LFTD (receiver operating characteristic area under the curve: 96.2%); MDs from both eyes offered no significant extra diagnostic power (area under the curve: 96.4%). PoF for BEMD thresholds of ≤-10 dB and ≤-14 dB were 70 (95% CI 66% to 74%) and 92% (87% to 95%), respectively. There is a strong relationship between BEMD and a patient's LFTD. PoF values for LFTD associated with readily available MD values provide practical landmarks for VF disability in glaucoma.

  4. Firefighters' hearing: a comparison with population databases from the International Standards Organization.

    PubMed

    Kales, S N; Freyman, R L; Hill, J M; Polyhronopoulos, G N; Aldrich, J M; Christiani, D C

    2001-07-01

    We investigated firefighters' hearing relative to general population data to adjust for age-expected hearing loss. For five groups of male firefighters with increasing mean ages, we compared their hearing thresholds at the 50th and 90th percentiles with normative and age- and sex-matched hearing data from the International Standards Organization (databases A and B). At the 50th percentile, from a mean age of 28 to a mean age of 53 years, relative to databases A and B, the firefighters lost an excess of 19 to 23 dB, 20 to 23 dB, and 16 to 19 dB at 3000, 4000, and 6000 Hz, respectively. At the 90th percentile, from a mean age of 28 to a mean age of 53 years, relative to databases A and B, the firefighters lost an excess of 12 to 20 dB, 38 to 44 dB, 41 to 45 dB, and 22 to 28 dB at 2000, 3000, 4000, and 6000 Hz, respectively. The results are consistent with accelerated hearing loss in excess of age-expected loss among the firefighters, especially at or above the 90th percentile.

  5. Measurement precision in a series of visual fields acquired by the standard and fast versions of the Swedish interactive thresholding algorithm: analysis of large-scale data from clinics.

    PubMed

    Saunders, Luke J; Russell, Richard A; Crabb, David P

    2015-01-01

    Swedish Interactive Thresholding Algorithm (SITA) testing strategies for the Humphrey Field Analyzer have become a clinical standard. Measurements from SITA Fast are thought to be more variable than SITA Standard, yet some clinics routinely use SITA Fast because it is quicker. To examine the measurement precision of the 2 SITA strategies across a range of sensitivities using a large number of visual field (VF) series from 4 glaucoma clinics in England. Retrospective cohort study at Moorfields Eye Hospital in London, England; Gloucestershire Eye Unit at Cheltenham General Hospital; Queen Alexandra Hospital in Portsmouth, England; and the Calderdale and Huddersfield National Health Service Foundation Trust that included 66,974 Humphrey 24-2 SITA Standard VFs (10,124 eyes) and 19,819 Humphrey 24-2 SITA Fast VFs (3654 eyes) recorded between May 20, 1997, and September 20, 2012. Pointwise ordinary least squares linear regression of measured sensitivity over time was conducted using VF series of 1 random eye from each patient. Residuals from the regression were pooled according to fitted sensitivities. For each sensitivity (decibel) level, the standard deviation of the residuals was used to estimate measurement precision and were compared for SITA Standard and SITA Fast. Simulations of progression from different VF baselines were used to evaluate how different levels of precision would affect time to detect VF progression. Median years required to detect progression. Median (interquartile range) patient age, follow-up, and series lengths for SITA Standard were 64 (53-72) years, 6.0 (4.0-8.5) years, and 6 (4-8) VFs, respectively; for SITA Fast, medians (interquartile range) were 70 (61-78) years, 5.1 (3.2-7.3) years, and 5 (4-6) VFs. Measurement precision worsened as sensitivity decreased for both test strategies. In the 20 to 5 dB range, SITA Fast was less precise than SITA Standard; this difference was largest between 15 to 10 dB, where variability in both methods peaked. Translated to median time to detection, differences in measurement precision were negligible, suggesting minimal effects on time to detect progression. Although SITA Standard is a more precise testing algorithm than SITA Fast at lower VF sensitivities, it is unlikely to make a sizeable difference to improving the time to detect VF progression.

  6. An expandable crosstalk reduction method for inline fiber Fabry-Pérot sensor array based on fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Jiang, Peng; Ma, Lina; Hu, Zhengliang; Hu, Yongming

    2016-07-01

    The inline time division multiplexing (TDM) fiber Fabry-Pérot (FFP) sensor array based on fiber Bragg gratings (FBGs) is attractive for many applications. But the intrinsic multi-reflection (MR) induced crosstalk limits applications especially those needing high resolution. In this paper we proposed an expandable method for MR-induced crosstalk reduction. The method is based on complexing-exponent synthesis using the phase-generated carrier (PGC) scheme and the special common character of the impulse responses. The method could promote demodulation stability simultaneously with the reduction of MR-induced crosstalk. A polarization-maintaining 3-TDM experimental system with an FBG reflectivity of about 5 % was set up to validate the method. The experimental results showed that crosstalk reduction of 13 dB and 15 dB was achieved for sensor 2 and sensor 3 respectively when a signal was applied to the first sensor and crosstalk reduction of 8 dB was achieved for sensor 3 when a signal was applied to sensor 2. The demodulation stability of the applied signal was promoted as well. The standard deviations of the amplitude distributions of the demodulated signals were reduced from 0.0046 to 0.0021 for sensor 2 and from 0.0114 to 0.0044 for sensor 3. Because of the convenience of the linear operation of the complexing-exponent and according to the common character of the impulse response we found, the method can be effectively extended to the array with more TDM channels if the impulse response of the inline FFP sensor array with more TDM channels is derived. It offers potential to develop a low-crosstalk inline FFP sensor array using the PGC interrogation technique with relatively high reflectivity FBGs which can guarantee enough light power received by the photo-detector.

  7. Acoustic properties of healthy and reconstructed cleft lip

    NASA Astrophysics Data System (ADS)

    Thijssen, Johan M.; van Hees, Nancy J.; Weijers, Gert G.; Huyskens, Rinske W.; Nillesen, Maartje; Katsaros, Christos; de Korte, Chris L.

    2006-03-01

    The feasibility of echographic imaging of the tissues in healthy lip and in reconstructed cleft lip and estimating the dimensions and the normalized echo level of these tissues is investigated. Echographic images of the upper lip were made with commercial medical ultrasound equipment, using a linear array transducer (7-11 MHz bandwidth) and a non-contact gel coupling. Tissue dimensions were measured by means of software calipers. Echo levels were calibrated and corrected for beam characteristics, gel path and tissue attenuation by using a tissue-mimicking phantom. At central position of philtrum, mean thickness (and standard deviation) of lip loose connective tissue layer, orbicularis oris muscle and dense connective layer was 4.0 (sd 0.1) mm, 2.3 (sd 0.7) mm, 2.2 (sd 0.7) mm, respectively, in healthy lip at rest. Mean (sd) echo level of muscle and dense connective tissue layer with respect to echo level of lip loose connective tissue layer was in relaxed condition: - 19.3 (sd 0.6) dB and - 10.7 (sd 4.0) dB, respectively. Echo level of loose connective tissue layer was +25.6 (sd 4.2) dB relative to phantom echo level obtained in the focus of the transducer. Color mode echo images were calculated, after adaptive filtering of the images, which show the tissues in separate colors and highlight the details of healthy lip and reconstructed cleft lip. Quantitative assessment of thickness and echo level of various lip tissues is feasible after proper calibration of the echographic equipment. Diagnostic potentials of the developed quantitative echographic techniques for non-invasive evaluation of the outcome of cleft lip reconstruction are promising.

  8. The Idiopathic Intracranial Hypertension Treatment Trial

    PubMed Central

    Wall, Michael; Kupersmith, Mark J.; Kieburtz, Karl D.; Corbett, James J.; Feldon, Steven E.; Friedman, Deborah I.; Katz, David M.; Keltner, John L.; Schron, Eleanor B.; McDermott, Michael P.

    2015-01-01

    IMPORTANCE To our knowledge, there are no large prospective cohorts of untreated patients with idiopathic intracranial hypertension (IIH) to characterize the disease. OBJECTIVE To report the baseline clinical and laboratory features of patients enrolled in the Idiopathic Intracranial Hypertension Treatment Trial. DESIGN, SETTING, AND PARTICIPANTS We collected data at baseline from questionnaires, examinations, automated perimetry, and fundus photography grading. Patients (n = 165) were enrolled from March 17, 2010, to November 27, 2012, at 38 academic and private practice sites in North America. All participants met the modified Dandy criteria for IIH and had a perimetric mean deviation between −2 dB and −7 dB. All but 4 participants were women. MAIN OUTCOMES AND MEASURES Baseline and laboratory characteristics. RESULTS The mean (SD) age of our patients was 29.0 (7.4) years and 4 (2.4%) were men. The average (SD) body mass index (calculated as weight in kilograms divided by height in meters squared) was 39.9 (8.3). Headache was the most common symptom (84%). Transient visual obscurations occurred in 68% of patients, back pain in 53%, and pulse synchronous tinnitus in 52%. Only 32% reported visual loss. The average (SD) perimetric mean deviation in the worst eye was −3.5 (1.1) dB, (range, −2.0 to −6.4 dB) and in the best eye was −2.3 (1.1) dB (range, −5.2 to 0.8 dB). A partial arcuate visual field defect with an enlarged blind spot was the most common perimetric finding. Visual acuity was 85 letters or better (20/20) in 71% of the worst eyes and 77% of the best eyes. Quality of life measures, including the National Eye Institute Visual Function Questionnaire–25 and the Short Form–36 physical and mental health summary scales, were lower compared with population norms. CONCLUSIONS AND RELEVANCE The Idiopathic Intracranial Hypertension Treatment Trial represents the largest prospectively analyzed cohort of untreated patients with IIH. Our data show that IIH is almost exclusively a disease of obese young women. Patients with IIH with mild visual loss have typical symptoms, may have mild acuity loss, and have visual field defects, with predominantly arcuate loss and enlarged blind spots that require formal perimetry for detection. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01003639 PMID:24756302

  9. Multipath interference test method for distributed amplifiers

    NASA Astrophysics Data System (ADS)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  10. Personal noise dosimeters: accuracy and reliability in varied settings.

    PubMed

    Cook-Cunningham, Sheri Lynn

    2014-01-01

    This study investigated the accuracy, reliability, and characteristics of three brands of personal noise dosimeters (N = 7 units) in both pink noise (PN) environments and natural environments (NEs) through the acquisition of decibel readings, Leq readings and noise doses. Acquisition periods included repeated PN conditions, choir room rehearsals and participant (N = 3) Leq and noise dosages procured during a day in the life of a music student. Among primary results: (a) All dosimeters exhibited very strong positive correlations for PN measurements across all instruments; (b) all dosimeters were within the recommended American National Standard Institute (ANSI) SI.25-1991 standard of ±2 dB (A) of a reference measurement; and (c) all dosimeters were within the recommended ANSI SI.25-1991 standard of ±2 dB (A) when compared with each other. Results were discussed in terms of using personal noise dosimeters within hearing conservation and research contexts and recommendations for future research. Personal noise dosimeters were studied within the contexts of PN environments and NEs (choral classroom and the day in the life of collegiate music students). This quantitative study was a non-experimental correlation design. Three brands of personal noise dosimeters (Cirrus doseBadge, Quest Edge Eg5 and Etymotic ER200D) were tested in two environments, a PN setting and a natural setting. There were two conditions within each environment. In the PN environment condition one, each dosimeter was tested individually in comparison with two reference measuring devices (Ivie and Easera) while PN was generated by a Whites Instrument PN Tube. In condition two, the PN procedures were replicated for longer periods while all dosimeters measured the sound levels simultaneously. In the NE condition one, all dosimeters were placed side by side on a music stand and recorded sound levels of choir rehearsals over a 7-h rehearsal period. In NE, condition two noise levels were measured during a day in the life of college music students. Three participants each wore two types of dosimeters for an 8-h period during a normal school day. Descriptive statistical analyzes including means, standard deviation and Pearson product-moment correlation. The primary finding is that the dosimeters in this study recorded results within ±2 dB of either a reference measurement or within dosimeters in all four conditions examined. All dosimeters studied measured steady noise source accurately and consistently, with strong positive correlations across all instruments. Measurements acquired during choral rehearsals indicated a maximum of 1.5 dB difference across dosimeters. The Etymotic research personal noise dosimeters (ER200D) could provide individuals and schools of music with a relatively inexpensive tool to monitor sound doses. Findings from this study suggest that the three brands of dosimeters tested will provide reliable Leq levels and hearing dosages in both PN and natural settings.

  11. Resistance Training Increases the Variability of Strength Test Scores

    DTIC Science & Technology

    2009-06-08

    standard deviations for pretest and posttest strength measurements. This information was recorded for every strength test used in a total of 377 samples...significant if the posttest standard deviation consistently was larger than the pretest standard deviation. This condition could be satisfied even if...the difference in the standard deviations was small. For example, the posttest standard deviation might be 1% larger than the pretest standard

  12. COOMET pilot comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 kHz

    NASA Astrophysics Data System (ADS)

    Yi, Chen; Isaev, A. E.; Yuebing, Wang; Enyakov, A. M.; Teng, Fei; Matveev, A. N.

    2011-01-01

    A description is given of the COOMET project 473/RU-a/09: a pilot comparison of hydrophone calibrations at frequencies from 250 Hz to 200 kHz between Hangzhou Applied Acoustics Research Institute (HAARI, China)—pilot laboratory—and Russian National Research Institute for Physicotechnical and Radio Engineering Measurements (VNIIFTRI, Designated Institute of Russia of the CIPM MRA). Two standard hydrophones, B&K 8104 and TC 4033, were calibrated and compared to assess the current state of hydrophone calibration of HAARI (China) and Russia. Three different calibration methods were applied: a vibrating column method, a free-field reciprocity method and a comparison method. The standard facilities of each laboratory were used, and three different sound fields were applied: pressure field, free-field and reverberant field. The maximum deviation of the sensitivities of two hydrophones between the participants' results was 0.36 dB. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV-KCWG.

  13. Polarimetry With Phased Array Antennas: Theoretical Framework and Definitions

    NASA Astrophysics Data System (ADS)

    Warnick, Karl F.; Ivashina, Marianna V.; Wijnholds, Stefan J.; Maaskant, Rob

    2012-01-01

    For phased array receivers, the accuracy with which the polarization state of a received signal can be measured depends on the antenna configuration, array calibration process, and beamforming algorithms. A signal and noise model for a dual-polarized array is developed and related to standard polarimetric antenna figures of merit, and the ideal polarimetrically calibrated, maximum-sensitivity beamforming solution for a dual-polarized phased array feed is derived. A practical polarimetric beamformer solution that does not require exact knowledge of the array polarimetric response is shown to be equivalent to the optimal solution in the sense that when the practical beamformers are calibrated, the optimal solution is obtained. To provide a rough initial polarimetric calibration for the practical beamformer solution, an approximate single-source polarimetric calibration method is developed. The modeled instrumental polarization error for a dipole phased array feed with the practical beamformer solution and single-source polarimetric calibration was -10 dB or lower over the array field of view for elements with alignments perturbed by random rotations with 5 degree standard deviation.

  14. Thermodynamic criteria for estimating the kinetic parameters of catalytic reactions

    NASA Astrophysics Data System (ADS)

    Mitrichev, I. I.; Zhensa, A. V.; Kol'tsova, E. M.

    2017-01-01

    Kinetic parameters are estimated using two criteria in addition to the traditional criterion that considers the consistency between experimental and modeled conversion data: thermodynamic consistency and the consistency with entropy production (i.e., the absolute rate of the change in entropy due to exchange with the environment is consistent with the rate of entropy production in the steady state). A special procedure is developed and executed on a computer to achieve the thermodynamic consistency of a set of kinetic parameters with respect to both the standard entropy of a reaction and the standard enthalpy of a reaction. A problem of multi-criterion optimization, reduced to a single-criterion problem by summing weighted values of the three criteria listed above, is solved. Using the reaction of NO reduction with CO on a platinum catalyst as an example, it is shown that the set of parameters proposed by D.B. Mantri and P. Aghalayam gives much worse agreement with experimental values than the set obtained on the basis of three criteria: the sum of the squares of deviations for conversion, the thermodynamic consistency, and the consistency with entropy production.

  15. Performance and characterization of new micromachined high-frequency linear arrays.

    PubMed

    Lukacs, Marc; Yin, Jianhua; Pang, Guofeng; Garcia, Richard C; Cherin, Emmanuel; Williams, Ross; Mehi, Jim; Foster, F Stuart

    2006-10-01

    A new approach for fabricating high frequency (> 20 MHz) linear array transducers, based on laser micromachining, has been developed. A 30 MHz, 64-element, 74-microm pitch, linear array design is presented. The performance of the device is demonstrated by comparing electrical and acoustic measurements with analytical, equivalent circuit, and finite-element analysis (FEA) simulations. All FEA results for array performance have been generated using one global set of material parameters. Each fabricated array has been integrated onto a flex circuit for ease of handling, and the flex has been integrated onto a custom printed circuit board test card for ease of testing. For a fully assembled array, with an acoustic lens, the center frequency was 28.7 MHz with a one-way -3 dB and -6 dB bandwidth of 59% and 83%, respectively, and a -20 dB pulse width of -99 ns. The per-element peak acoustic power, for a +/- 30 V single cycle pulse, measured at the 10 mm focal length of the lens was 590 kPa with a -6 dB directivity span of about 30 degrees. The worst-case total cross talk of the combined array and flex assembly is for nearest neighboring elements and was measured to have an average level -40 dB across the -6 dB bandwidth of the device. Any significant deviation from simulation can be explained through limitations in apparatus calibration and in device packaging.

  16. Estimate of standard deviation for a log-transformed variable using arithmetic means and standard deviations.

    PubMed

    Quan, Hui; Zhang, Ji

    2003-09-15

    Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.

  17. Ship noise extends to frequencies used for echolocation by endangered killer whales

    PubMed Central

    Veirs, Val; Wood, Jason D.

    2016-01-01

    Combining calibrated hydrophone measurements with vessel location data from the Automatic Identification System, we estimate underwater sound pressure levels for 1,582 unique ships that transited the core critical habitat of the endangered Southern Resident killer whales during 28 months between March, 2011, and October, 2013. Median received spectrum levels of noise from 2,809 isolated transits are elevated relative to median background levels not only at low frequencies (20–30 dB re 1 µPa2/Hz from 100 to 1,000 Hz), but also at high frequencies (5–13 dB from 10,000 to 96,000 Hz). Thus, noise received from ships at ranges less than 3 km extends to frequencies used by odontocetes. Broadband received levels (11.5–40,000 Hz) near the shoreline in Haro Strait (WA, USA) for the entire ship population were 110 ± 7 dB re 1 µPa on average. Assuming near-spherical spreading based on a transmission loss experiment we compute mean broadband source levels for the ship population of 173 ± 7 dB re 1 µPa 1 m without accounting for frequency-dependent absorption. Mean ship speed was 7.3 ± 2.0 m/s (14.1 ± 3.9 knots). Most ship classes show a linear relationship between source level and speed with a slope near +2 dB per m/s (+1 dB/knot). Spectrum, 1/12-octave, and 1/3-octave source levels for the whole population have median values that are comparable to previous measurements and models at most frequencies, but for select studies may be relatively low below 200 Hz and high above 20,000 Hz. Median source spectrum levels peak near 50 Hz for all 12 ship classes, have a maximum of 159 dB re 1 µPa2/Hz @ 1 m for container ships, and vary between classes. Below 200 Hz, the class-specific median spectrum levels bifurcate with large commercial ships grouping as higher power noise sources. Within all ship classes spectrum levels vary more at low frequencies than at high frequencies, and the degree of variability is almost halved for classes that have smaller speed standard deviations. This is the first study to present source spectra for populations of different ship classes operating in coastal habitats, including at higher frequencies used by killer whales for both communication and echolocation. PMID:27004149

  18. M&S Smart System Contrast Sensitivity Measurements Compared With Standard Visual Function Measurements in Primary Open-Angle Glaucoma Patients.

    PubMed

    Liu, Jessica L; McAnany, J Jason; Wilensky, Jacob T; Aref, Ahmad A; Vajaranant, Thasarat S

    2017-06-01

    To evaluate the nature and extent of letter contrast sensitivity (CS) deficits in glaucoma patients using a commercially available computer-based system (M&S Smart System II) and to compare the letter CS measurements to standard clinical measures of visual function. Ninety-four subjects with primary open-angle glaucoma participated. Each subject underwent visual acuity, letter CS, and standard automated perimetry testing (Humphrey SITA 24-2). All subjects had a best-corrected visual acuity (BCVA) of 0.3 log MAR (20/40 Snellen equivalent) or better and reliable standard automated perimetry (fixation losses, false positives, and false negatives <33%). CS functions were estimated from the letter CS and BCVA measurements. The area under the CS function (AUCSF), which is a combined index of CS and BCVA, was derived and analyzed. The mean (± SD) BCVA was 0.08±0.10 log MAR (∼20/25 Snellen equivalent), the mean CS was 1.38±0.17, and the mean Humphrey Visual Field mean deviation (HVF MD) was -7.22±8.10 dB. Letter CS and HVF MD correlated significantly (r=0.51, P<0.001). BCVA correlated significantly with letter CS (r=-0.22, P=0.03), but not with HVF MD (r=-0.12, P=0.26). A subset of the subject sample (∼20%) had moderate to no field loss (≤-6 dB MD) and minimal to no BCVA loss (≤0.3 log MAR), but had poor letter CS. AUCSF was correlated significantly with HVF MD (r=0.46, P<0.001). The present study is the first to evaluate letter CS in glaucoma using the digital M&S Smart System II display. Letter CS correlated significantly with standard HVF MD measurements, suggesting that letter CS may provide a useful adjunct test of visual function for glaucoma patients. In addition, the significant correlation between HVF MD and the combined index of CS and BCVA (AUCSF) suggests that this measure may also be useful for quantifying visual dysfunction in glaucoma patients.

  19. Morphological and functional differences between normal-tension and high-tension glaucoma.

    PubMed

    Häntzschel, Janek; Terai, Naim; Sorgenfrei, Friederike; Haustein, Michael; Pillunat, Karin; Pillunat, Lutz E

    2013-08-01

    To compare visual field (VF) and nerve fibre loss in patients with normal-tension (NTG) and high-tension glaucoma (HTG) at an equal level of glaucomatous structural damage of the optic nerve head (ONH). In a retrospective, pair-matched, comparative study, 126 eyes with NTG and 126 eyes with HTG were matched according to the same glaucomatous ONH damage based on rim volume, rim area and disc size measured by the Heidelberg Retina Tomograph (HRT III). Visual field by Humphrey perimetry and nerve fibre layer thickness measured by scanning laser polarimetry (GdxVCC) were compared between both groups. Based on the HRT, NTG and HTG displayed comparable structural damage of the ONH without a statistically significant difference between both groups (mean, NTG/HTG: disc area 2.32/2.32 mm², p =0.342; rim area 1.03/1.00 mm², p = 0.279; rim volume 0.2/0.19 mm³; p = 0.274). Eyes with NTG had significantly less VF damage than eyes with HTG (mean, NTG/HTG: mean deviation (MD) -3.69/-9.77 dB, p = 0.0001; pattern standard deviation (PSD) 4.80/7.17 dB, p = 0.0001). The nerve fibre layer of NTG patients was thicker than that of HTG patients (mean, NTG/HTG: GDx total: 46.9/44.0 μm, p = 0.073; GDx superior: 57.2/49.9 μm, p = 0.0001; GDx inferior: 54.9/49.7 μm, p = 0.001). At an equal level of glaucomatous structural damage of the ONH indicated by cupping, rim area and rim volume, NTG patients seem to have a less affected visual field and a better preserved nerve fibre layer than HTG patients. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.

  20. Baseline mean deviation and rates of visual field change in treated glaucoma patients.

    PubMed

    Forchheimer, I; de Moraes, C G; Teng, C C; Folgar, F; Tello, C; Ritch, R; Liebmann, J M

    2011-05-01

    To evaluate the relationships between baseline visual field (VF) mean deviation (MD) and subsequent progression in treated glaucoma. Records of patients seen in a glaucoma practice between 1999 and 2009 were reviewed. Patients with glaucomatous optic neuropathy, baseline VF damage, and ≥8 SITA-standard 24-2 VF were included. Patients were divided into tertiles based upon baseline MD. Automated pointwise linear regression determined global and localized rates (decibels (dB) per year) of change. Progression was defined when two or more adjacent test locations in the same hemifield showed a sensitivity decline at a rate of >1.0  dB per year, P<0.01. For mild, moderate, and severe groups, progression was noted in 29.5, 31.2, and 26.0% of eyes (P=0.50) and global rates of VF change of progressing eyes were -1.3±1.2, -1.01±0.7, and -0.9±0.5 dB/year (P=0.09, analysis of variance). Within these groups, intraocular pressure (IOP) in stable vs progressing eyes were 15.5±3.3 vs 17.0±3.1 (P<0.01), 15.4±3.3 vs 15.9±2.5 (P=0.28), and 14.0±2.8 vs 14.8±2.3 mm Hg (P=0.07). More glaucoma filtering surgeries were performed in eyes with worse MD. There was no significant difference between groups regarding their risk of progression in both univariate (P=0.50) and multivariate (P=0.26) analyses adjusting for differences in follow-up IOP. After correcting for differences in IOP in treated glaucoma patients, we did not find a relationship between the rate of VF change (dB per year) and the severity of the baseline VF MD. This finding may have been due to more aggressive IOP lowering in eyes with more severe disease. Eyes with lower IOP progressed less frequently across the spectrum of VF loss.

  1. 47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...

  2. 47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...

  3. 47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...

  4. 47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...

  5. 47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...

  6. 40 CFR 201.11 - Standard for locomotive operation under stationary conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... completed on or before December 31, 1979, which produces A-weighted sound levels in excess of 93 dB at any..., 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except idle... December 31, 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except...

  7. 40 CFR 201.11 - Standard for locomotive operation under stationary conditions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... completed on or before December 31, 1979, which produces A-weighted sound levels in excess of 93 dB at any..., 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except idle... December 31, 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except...

  8. Multimode optical fibers: steady state mode exciter.

    PubMed

    Ikeda, M; Sugimura, A; Ikegami, T

    1976-09-01

    The steady state mode power distribution of the multimode graded index fiber was measured. A simple and effective steady state mode exciter was fabricated by an etching technique. Its insertion loss was 0.5 dB for an injection laser. Deviation in transmission characteristics of multimode graded index fibers can be avoided by using the steady state mode exciter.

  9. Experimental Structural Dynamic Response of Plate Specimens Due to Sonic Loads in a Progressive Wave Tube

    NASA Technical Reports Server (NTRS)

    Betts, Juan F.

    2001-01-01

    The objective of the current study was to assess the repeatability of experiments at NASA Langley's Thermal Acoustic Fatigue Apparatus (TAFA) facility and to use these experiments to validate numerical models. Experiments show that power spectral density (PSD) curves were repeatable except at the resonant frequencies, which tended to vary between 5 Hz to 15 Hz. Results show that the thinner specimen had more variability in the resonant frequency location than the thicker sample, especially for modes higher than the first mode in the frequency range. Root Mean Square (RMS) tended to be more repeatable. The RMS behaved linearly through the SPL range of 135 to 153 dB. Standard Deviations (STDs) of the results tended to be relatively low constant up to about 147 dB. The RMS results were more repeatable than the PDS results. The STD results were less than 10% of the RMS results for both the 0.125 in (0.318 cm) and 0.062 in (0.1588 cm) thick plate. The STD of the PSD results were around 20% to 100% of the mean PSD results for non-resonant and resonant frequencies, respectively, for the 0.125 in (0.318 cm) thicker plate and between 25% to 125% of the mean PSD results, for nonresonant and resonant frequencies, respectively, for the thinner plate.

  10. 7 CFR 400.204 - Notification of deviation from standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...

  11. Ultra compact triplexing filters based on SOI nanowire AWGs

    NASA Astrophysics Data System (ADS)

    Jiashun, Zhang; Junming, An; Lei, Zhao; Shijiao, Song; Liangliang, Wang; Jianguang, Li; Hongjie, Wang; Yuanda, Wu; Xiongwei, Hu

    2011-04-01

    An ultra compact triplexing filter was designed based on a silicon on insulator (SOI) nanowire arrayed waveguide grating (AWG) for fiber-to-the-home FTTH. The simulation results revealed that the design performed well in the sense of having a good triplexing function. The designed SOI nanowire AWGs were fabricated using ultraviolet lithography and induced coupler plasma etching. The experimental results showed that the crosstalk was less than -15 dB, and the 3 dB-bandwidth was 11.04 nm. The peak wavelength output from ports a, c, and b were 1455, 1510 and 1300 nm, respectively, which deviated from our original expectations. The deviation of the wavelength is mainly caused by 45 nm width deviation of the arrayed waveguides during the course of the fabrication process and partly caused by material dispersion.

  12. Signal/noise analysis to compare tests for measuring visual field loss and its progression.

    PubMed

    Artes, Paul H; Chauhan, Balwantray C

    2009-10-01

    To describe a methodology for establishing signal-to-noise ratios (SNRs) for different perimetric techniques, and to compare SNRs of frequency-doubling technology (FDT2) perimetry and standard automated perimetry (SAP). Fifteen patients with open-angle glaucoma (median MD, -2.6 dB, range +0.2 to -16.1 dB) were tested six times with FDT2 and SAP (SITA Standard program 24-2) within a 4-week period. Signals were estimated from the average superior-inferior difference between the mean deviation (MD) values in five mirror-pair sectors of the Glaucoma Hemifield Test, and noise from the dispersion of these differences over the six repeated tests. SNRs of FDT2 and SAP were compared by mixed-effects modeling. There was moderate correlation between the signals of FDT2 and SAP (r(2) = 0.68, P < 0.001), but no correlation of noise (r(2) = 0.01, P = 0.16). Although both signal as well as noise estimates were higher with FDT2 compared with SAP, 60% to 70% of sector pairs showed higher SNRs with FDT2. The SNRs of FDT2 were between 20% and 40% higher than those of SAP (P = 0.01). There were no meaningful differences between parametric and nonparametric estimates of signal, noise, or SNR. The higher SNRs of FDT2 suggest that this technique is at least as efficient as SAP at detecting localized visual field losses. Signal/noise analyses may provide a useful approach for comparing visual field tests independent of their decibel scales and may provide an initial indication of sensitivity to visual field change over time.

  13. NASA ER-2 Doppler radar reflectivity calibration for the CAMEX project

    NASA Technical Reports Server (NTRS)

    Caylor, I. J.; Heymsfield, G. M.; Bidwell, S. W.; Ameen, S.

    1994-01-01

    The NASA ER-2 Doppler radar (EDOP) was flown aboard the ER-2 high-altitude aircraft in September and October 1993 for the Convection and Moisture Experiment. During these flights, the first reliable reflectivity observations were performed with the EDOP instrument. This report details the procedure used to convert real-time engineering data into calibrated radar reflectivity. Application of the calibration results produces good agreement between the EDOP nadir pointing reflectivity and ground truth provided by a National Weather Service WSR-88D radar. The rms deviation between WSR-88D and EDOP is 6.9 dB, while measurements of the ocean surface backscatter coefficient are less than 3 dB from reported scatterometer coefficients. After an initial 30-minute period required for the instrument to reach thermal equilibrium, the radar is stable to better than 0.25 dB during flight. The range performance of EDOP shows excellent agreement with aircraft altimeter and meteorological sounding data.

  14. Air displacement plethysmography: validation in overweight and obese subjects.

    PubMed

    Ginde, Samir R; Geliebter, Allan; Rubiano, Frederick; Silva, Analiza M; Wang, Jack; Heshka, Stanley; Heymsfield, Steven B

    2005-07-01

    Patients with moderate and severe obesity, because of their physical size, often cannot be evaluated with conventional body composition measurement systems. The BOD POD air displacement plethysmography (ADP) system can accommodate a large body volume and may provide an opportunity for measuring body density (D(b)) in obese subjects. D(b) can be used in two- or three-compartment body composition models for estimating total body fat in patients with severe obesity. The purpose of this study was to compare D(b) measured by ADP to D(b) measured by underwater weighing (UWW) in subjects ranging from normal weight to severely obese. D(b) was measured with UWW and BOD POD in 123 subjects (89 men and 34 women; age, 46.5 +/- 16.9 years; BMI, 31.5 +/- 7.3 kg/m2); 15, 70, and 10 subjects were overweight (25 < or = BMI < 30 kg/m2), obese (30 < or = BMI < 40 kg/m2), and severely obese (BMI > or = 40 kg/m2), respectively. There was a strong correlation between D(b) (kilograms per liter) measured by UWW and ADP (r = 0.94, standard error of the estimate = 0.0073 kg/L, p < 0.001). Similarly, percent fat estimates from UWW and ADP using the two-compartment Siri equation were highly correlated (r = 0.94, standard error of the estimate = 3.58%, p < 0.001). Bland-Altman analysis showed no significant bias between D(b) measured by UWW and ADP. After controlling for D(b) measured by ADP, no additional between-subject variation in D(b) by UWW was accounted for by subject age, sex, or BMI. Body density, an important physical property used in human body composition models, can be accurately measured by ADP in overweight and obese subjects.

  15. Coupling losses between standard single-mode fibers and rectangular waveguides for integrated optics.

    PubMed

    Lierstuen, L O; Sudbø, A S

    1995-02-20

    The butt-coupling loss between different tapered rectangular waveguides and a standard single-mode optical fiber has been calculated. Losses as low as 0.16 dB can be reached for waveguides with a refractive-index contrast in the range of 0.5% to 1.96%. The fabrication tolerances are such that practical devices with coupling losses below 0.25 dB are feasible.

  16. GeneSigDB—a curated database of gene expression signatures

    PubMed Central

    Culhane, Aedín C.; Schwarzl, Thomas; Sultana, Razvan; Picard, Kermshlise C.; Picard, Shaita C.; Lu, Tim H.; Franklin, Katherine R.; French, Simon J.; Papenhausen, Gerald; Correll, Mick; Quackenbush, John

    2010-01-01

    The primary objective of most gene expression studies is the identification of one or more gene signatures; lists of genes whose transcriptional levels are uniquely associated with a specific biological phenotype. Whilst thousands of experimentally derived gene signatures are published, their potential value to the community is limited by their computational inaccessibility. Gene signatures are embedded in published article figures, tables or in supplementary materials, and are frequently presented using non-standard gene or probeset nomenclature. We present GeneSigDB (http://compbio.dfci.harvard.edu/genesigdb) a manually curated database of gene expression signatures. GeneSigDB release 1.0 focuses on cancer and stem cells gene signatures and was constructed from more than 850 publications from which we manually transcribed 575 gene signatures. Most gene signatures (n = 560) were successfully mapped to the genome to extract standardized lists of EnsEMBL gene identifiers. GeneSigDB provides the original gene signature, the standardized gene list and a fully traceable gene mapping history for each gene from the original transcribed data table through to the standardized list of genes. The GeneSigDB web portal is easy to search, allows users to compare their own gene list to those in the database, and download gene signatures in most common gene identifier formats. PMID:19934259

  17. Body-density measurement in children: the BOD POD versus Hydrodensitometry.

    PubMed

    Holmes, Jason C; Gibson, Ann L; Cremades, J Gualberto; Mier, Constance M

    2011-06-01

    To compare estimates of body density (Db) from air-displacement plethysmography (ADP) with measured and predicted thoracic-gas-volume (TGV) measurements and those from hydrodensitometry (HD) in children. Seventeen participants (13 male and 4 female; 10.1 ± 2.20 yr, 42.0 ± 15.03 kg, 145.6 ± 17.41 cm, 30.0 ± 8.66 kg/m²) were tested using ADP and HD, with ADP always preceding HD. Db estimates were compared between ADP with measured TGV, ADP with predicted TGV, and the reference measure, HD. Regression analyses were used to assess the accuracy of the ADP methods, and potential bias between the ADP procedures and HD were evaluated using Bland-Altman analyses. The cross-validation criteria described by Lohman for estimating Db relative to HD were used to interpret the results of the study. A significant difference was found between Db estimates from ADP with measured TGV (1.0453 ± 0.01934 g/cm³) and ADP with predicted TGV (1.0415 ± 0.01858 g/cm³); however, neither was significantly different from Db obtained by the reference HD procedure (1.0417 ± 0.02391 g/cm³). For both ADP procedures, regression analyses produced an r = .737-.738, r² = .543-.544, and SEE = 0.02 g/cm³, and the regression lines deviated significantly from the line of identity; however, no significant biases were indicated. Despite no significant mean differences between Db estimates from the ADP procedures and HD, more cross-validation research is needed before recommending the BOD POD for routine use with children in clinical and research settings.

  18. The Noisiness of Low Frequency Bands of Noise

    NASA Technical Reports Server (NTRS)

    Lawton, B. W.

    1975-01-01

    The relative noisiness of low frequency 1/3-octave bands of noise was examined. The frequency range investigated was bounded by the bands centered at 25 and 200 Hz, with intensities ranging from 50 to 95 db (SPL). Thirty-two subjects used a method of adjustment technique, producing comparison band intensities as noisy as 100 and 200 Hz standard bands at 60 and 72 db. The work resulted in contours of equal noisiness for 1/3-octave bands, ranging in intensity from approximately 58 to 86 db (SPL). These contours were compared with the standard equal noisiness contours; in the region of overlap, between 50 and 200 Hz, the agreement was good.

  19. Efficacy Study of Novel Diamidine Compounds in a Trypanosoma evansi Goat Model

    PubMed Central

    Gillingwater, Kirsten; Gutierrez, Carlos; Bridges, Arlene; Wu, Huali; Deborggraeve, Stijn; Ali Ekangu, Rosine; Kumar, Arvind; Ismail, Mohamed; Boykin, David; Brun, Reto

    2011-01-01

    Three diamidines (DB 75, DB 867 and DB 1192) were selected and their ability to cure T. evansi experimentally infected goats was investigated. A toxicity assessment and pharmacokinetic analysis of these compounds were additionally carried out. Goats demonstrated no signs of acute toxicity, when treated with four doses of 1 mg/kg/day (total dose 4 mg/kg). Complete curative efficacy of experimentally infected goats was seen in the positive control group treated with diminazene at 5 mg/kg and in the DB 75 and DB 867 groups treated at 2.5 mg/kg. Drug treatment was administered once every second day for a total of seven days. Complete cure was also seen in the group of goats treated with DB 75 at 1.25 mg/kg. DB 1192 was incapable of curing goats at either four-times 2.5 mg/kg or 1.25 mg/kg. Pharmacokinetic analysis clearly demonstrated that the treatment failures of DB 1192 were due to sub-therapeutic compound levels in goat plasma, whilst compound levels for DB 75 and DB 867 remained well within the therapeutic window. In conclusion, two diamidine compounds (DB 75 and DB 867) presented comparable efficacy at lower doses than the standard drug diminazene and could be considered as potential clinical candidates against T. evansi infection. PMID:21698106

  20. Efficacy study of novel diamidine compounds in a Trypanosoma evansi goat model.

    PubMed

    Gillingwater, Kirsten; Gutierrez, Carlos; Bridges, Arlene; Wu, Huali; Deborggraeve, Stijn; Ekangu, Rosine Ali; Kumar, Arvind; Ismail, Mohamed; Boykin, David; Brun, Reto

    2011-01-01

    Three diamidines (DB 75, DB 867 and DB 1192) were selected and their ability to cure T. evansi experimentally infected goats was investigated. A toxicity assessment and pharmacokinetic analysis of these compounds were additionally carried out. Goats demonstrated no signs of acute toxicity, when treated with four doses of 1 mg/kg/day (total dose 4 mg/kg). Complete curative efficacy of experimentally infected goats was seen in the positive control group treated with diminazene at 5 mg/kg and in the DB 75 and DB 867 groups treated at 2.5 mg/kg. Drug treatment was administered once every second day for a total of seven days. Complete cure was also seen in the group of goats treated with DB 75 at 1.25 mg/kg. DB 1192 was incapable of curing goats at either four-times 2.5 mg/kg or 1.25 mg/kg. Pharmacokinetic analysis clearly demonstrated that the treatment failures of DB 1192 were due to sub-therapeutic compound levels in goat plasma, whilst compound levels for DB 75 and DB 867 remained well within the therapeutic window. In conclusion, two diamidine compounds (DB 75 and DB 867) presented comparable efficacy at lower doses than the standard drug diminazene and could be considered as potential clinical candidates against T. evansi infection.

  1. 7 CFR 400.174 - Notification of deviation from financial standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...

  2. Ku band low noise parametric amplifier

    NASA Technical Reports Server (NTRS)

    1976-01-01

    A low noise, K sub u-band, parametric amplifier (paramp) was developed. The unit is a spacecraft-qualifiable, prototype, parametric amplifier for eventual application in the shuttle orbiter. The amplifier was required to have a noise temperature of less than 150 K. A noise temperature of less than 120 K at a gain level of 17 db was achieved. A 3-db bandwidth in excess of 350 MHz was attained, while deviation from phase linearity of about + or - 1 degree over 50 MHz was achieved. The paramp operates within specification over an ambient temperature range of -5 C to +50 C. The performance requirements and the operation of the K sub u-band parametric amplifier system are described. The final test results are also given.

  3. [A focused sound field measurement system by LabVIEW].

    PubMed

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying

    2014-05-01

    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  4. Degrees of Freedom for Allan Deviation Estimates of Multiple Clocks

    DTIC Science & Technology

    2016-04-01

    Allan deviation . Allan deviation will be represented by σ and standard deviation will be represented by δ. In practice, when the Allan deviation of a...the Allan deviation of standard noise types. Once the number of degrees of freedom is known, an approximate confidence interval can be assigned by...measurement errors from paired difference data. We extend this approach by using the Allan deviation to estimate the error in a frequency standard

  5. Weather radar equation and a receiver calibration based on a slice approach

    NASA Astrophysics Data System (ADS)

    Yurchak, B. S.

    2012-12-01

    Two circumstances are essential when exploiting radar measurement of precipitation. The first circumstance is a correct physical-mathematical model linking parameters of a rainfall microstructure with a magnitude of a return signal (the weather radar equation (WRE)). The second is a precise measurement of received power that is fitted by a calibration of radar receiver. WRE for the spatially extended geophysical target (SEGT), such as cloud or rain, has been derived based on "slice" approach [1]. In this approach, the particles located close to the wavefront of the radar illumination are assumed to produce backscatter that is mainly coherent. This approach allows the contribution of the microphysical parameters of the scattering media to the radar cross section to be more comprehensive than the model based on the incoherent approach (e.g., Probert-Jones equation (PJE)). In the particular case, when the particle number fluctuations within slices pertain the Poisson law, the WRE derived is transformed to PJE. When Poisson index (standard deviation / mean number of particles) of a slice deviates from 1, the deviation of return power estimated by PJE from the actual value varies from +8 dB to - 12 dB. In general, the backscatter depends on mean, variance and third moment of the particle size distribution function (PSDF). The incoherent approach assumes only dependence on the sixth moment of PSDF (radar reflectivity Z). Additional difference from the classical estimate can be caused by a correlation between slice field reflectivity [2]. Overall, the deviation in particle statistics of a slice from the Poisson law is one of main physical factors that contribute to errors in radar precipitation measurements based on Z-conception. One of the components of calibration error is caused by difference between processing by weather radar receiver of the calibration pulse, and actual return signal from SEGT. A receiver with non uniform amplitude-frequency response (AFR) processes these signals with the same input power but with different radio-frequency spectrums (RFS). This causes different output magnitude due to different distortion experienced while RFS passing through a receiver filter. To assess the calibration error, RFS of signals from SEGT has been studied including theoretical, experimental and simulation stages [3]. It is shown that the return signal carrier wave is phase modulated due to overlapping of replicas of RF-probing pulse reflected from SEGT's slices. The RFSs depends on the phase statistics of the carrier wave and on RFS of the probing pulse. The bandwidth of SEGT's RFS is not greater than that of the probing pulse. Typical phase correlation interval was found to be around the same as that of the probing pulse duration. Application of a long calibration signal (proportional to SEGT extension) causes the error up to -1 dB for conventional radar with matched filter. To eliminate the calibration error, a power estimate of individual return waveform should be corrected with the transformation loss coefficient calculated based on RFS and AFR parameters. To embrace with calibration the high and low frequency parts of a receiver, the calibration should be performed with a long pulse. That long pulse is composed from adjoining replicas of a probe pulse with random initial phases and having the same magnitude governed by the power of probe pulse.

  6. 1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...

  7. The Noisiness of Low-Frequency One-Third Octave Bands of Noise. M.S. Thesis - Southampton Univ.

    NASA Technical Reports Server (NTRS)

    Lawton, B. W.

    1975-01-01

    This study examined the relative noisiness of low frequency one-third octave bands of noise bounded by the bands centered at 25 Hz and 200 Hz, with intensities ranging from 50 db sound pressure level (SPL) to 95 db SPL. The thirty-two subjects used a method-of-adjustment technique, producing comparison-band intensities as noisy as standard bands centered at 100 Hz and 200 Hz with intensities of 60 db SPL and 72 db SPL. Four contours of equal noisiness were developed for one-third octave bands, extending down to 25 Hz and ranging in intensity from approximately 58 db SPL to 86 db SPL. These curves were compared with the contours of equal noisiness of Kryter and Pearsons. In the region of overlap (between 50 Hz and 200 Hz) the agreement was good.

  8. Upgraded FAA Airfield Capacity Model. Volume 1. Supplemental User’s Guide

    DTIC Science & Technology

    1981-02-01

    SIGMAR (P4.0) cc 1-4 -standard deviation, in seconds, of arrival runway occupancy time (R.O.T.). SIGMAA (F4.0) cc 5-8 -standard deviation, in seconds...iI SI GMAC - The standard deviation of the time from departure clearance to start of roll. SIGMAR - The standard deviation of the arrival runway

  9. High aperture efficiency symmetric reflector antennas with up to 60 deg field of view

    NASA Astrophysics Data System (ADS)

    Rappaport, Carey M.; Craig, William P.

    1991-03-01

    A microwave single-reflector scanning antenna derived from an ellipse (rather than the usual parabola) which gives a much greater field of view is presented. This reflector combines reasonable scanning in one plane with good focusing in the other, and its scanning ability is superior to the torus and other single reflectors because it has much greater aperture efficiency and is thus smaller while having the same performance. The reflector surface is derived in two steps: a fourth-order even polynomial profile curve in the scan plane is found using least squares to minimize the scanned ray errors; then even polynomial terms in x and y that minimize astigmatism for both the unscanned and maximally scanned beams are added to form the three-dimensional surface. Numerical simulations of radiation patterns for a variety of antenna diameter and field-of-view cases give excellent results. The 60 deg scan case with 30-lambda-diameter aperture has only 0.2-dB peak gain deviation from ideal and first sidelobe levels below 14 dB down from peak gain. The 17 deg, 500-lambda case has only 0.8-dB gain variation and -14 to -11 dB sidelobe levels for approximately +/-68 beamwidths of scan, with focal length to aperture diameter ratio equal to about one.

  10. A Visual Model for the Variance and Standard Deviation

    ERIC Educational Resources Information Center

    Orris, J. B.

    2011-01-01

    This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.

  11. Variability of pesticide detections and concentrations in field replicate water samples collected for the National Water-Quality Assessment Program, 1992-97

    USGS Publications Warehouse

    Martin, Jeffrey D.

    2002-01-01

    Correlation analysis indicates that for most pesticides and concentrations, pooled estimates of relative standard deviation rather than pooled estimates of standard deviation should be used to estimate variability because pooled estimates of relative standard deviation are less affected by heteroscedasticity. The 2 Variability of Pesticide Detections and Concentrations in Field Replicate Water Samples, 1992–97 median pooled relative standard deviation was calculated for all pesticides to summarize the typical variability for pesticide data collected for the NAWQA Program. The median pooled relative standard deviation was 15 percent at concentrations less than 0.01 micrograms per liter (µg/L), 13 percent at concentrations near 0.01 µg/L, 12 percent at concentrations near 0.1 µg/L, 7.9 percent at concentrations near 1 µg/L, and 2.7 percent at concentrations greater than 5 µg/L. Pooled estimates of standard deviation or relative standard deviation presented in this report are larger than estimates based on averages, medians, smooths, or regression of the individual measurements of standard deviation or relative standard deviation from field replicates. Pooled estimates, however, are the preferred method for characterizing variability because they provide unbiased estimates of the variability of the population. Assessments of variability based on standard deviation (rather than variance) underestimate the true variability of the population. Because pooled estimates of variability are larger than estimates based on other approaches, users of estimates of variability must be cognizant of the approach used to obtain the estimate and must use caution in the comparison of estimates based on different approaches.

  12. Basic life support: evaluation of learning using simulation and immediate feedback devices1.

    PubMed

    Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi

    2017-10-30

    to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.

  13. [Simultaneous determination of seven residual solvents in bovis calculus artifactus by headspace gas chromatography].

    PubMed

    Chi, Shuyao; Wu, Dike; Sun, Jinhong; Ye, Ruhan; Wang, Xiaoyan

    2014-05-01

    A headspace gas chromatography (HS-GC) method was developed for the simultaneous determination of seven residual solvents (petroleum ether (60-90 degrees C), acetone, ethyl acetate, methanol, methylene chloride, ethanol and butyl acetate) in bovis calculus artifactus. The DB-WAX capillary column and flame ionization detector (FID) were used for the separation and detection of the residual solvents, and the internal standard method was used for the quantification. The chromatographic conditions, such as equilibrium temperature and equilibrium time, were optimized. Under the optimized conditions, all of the seven residual solvents showed good linear relationships with good correlation coefficients (not less than 0.999 3) in the prescribed concentration range. At three spiked levels, the recoveries for the seven residual solvents were 94.7%-105.2% with the relative standard deviations (RSDs) less than 3.5%. The limits of detection (LODs) of the method were 0.43-5.23 mg/L, and the limits of quantification (LOQs) were 1.25-16.67 mg/L. The method is simple, rapid, sensitive and accurate, and is suitable for the simultaneous determination of the seven residual solvents in bovis calculus artifactus.

  14. Gas chromatographic sulphur speciation in heavy crude oil using a modified standard D5623 method and microfluidic Deans switching.

    PubMed

    Heshka, Nicole E; Choy, Joanne M; Chen, Jinwen

    2017-12-29

    A modification to American Society for Testing and Materials (ASTM) method D5623 is proposed to enable successful and repeatable analysis of heavy crude oil samples. A two-dimensional gas chromatography configuration was implemented, with separation of sulphur compounds occurring on two columns. A Deans switch is used to enable heart-cutting of volatile sulphur compounds onto a DB-Sulfur stationary phase, and separation occurs concurrently with the backflushing of the primary column. The use of a sulphur-selective detector increases selectivity, and 22 volatile sulphur species are quantified in less than 15min, which is almost half the time of the original ASTM method. Samples ranging from light distillation cuts to whole crudes (boiling from 100°C to >750°C) were analyzed with minimal sample preparation. The calculated limit of detection was 0.7mg/kg, repeatability was 3% relative standard deviation (RSD), and a linear range of 1-250mg/kg was obtained, with an R 2 value of 0.994 or better, depending on the compound. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  15. DSN 70-meter antenna microwave optics design and performance improvements. Part 2: Comparison with measurements

    NASA Technical Reports Server (NTRS)

    Bathker, D. A.; Slobin, S. D.

    1989-01-01

    The measured Deep Space Network (DSN) 70-meter antenna performance at S- and X-bands is compared with the design expectations. A discussion of natural radio-source calibration standards is given. New estimates of DSN 64-meter antenna performance are given, based on improved values of calibration source flux and size correction. A comparison of the 64- and 70-meter performances shows that average S-band peak gain improvement is 1.94 dB, compared with a design expectation of 1.77 dB. At X-band, the average peak gain improvement is 2.12 dB, compared with the (coincidentally similar) design expectation of 1.77 dB. The average measured 70-meter S-band peak gain exceeds the nominal design-expected gain by 0.02 dB; the average measured 70-meter X-band peak gain is 0.14 dB below the nominal design-expected gain.

  16. Gender differences in children's voice use in a day care environment.

    PubMed

    Nygren, Mariana; Tyboni, Mikaela; Lindström, Fredric; McAllister, Anita; van Doorn, Jan

    2012-11-01

    The prevalence of dysphonia is higher in boys than in girls before puberty. This could be because of the differences in boys' and girls' voice use. Previous research on gender differences in prepubescent children's voice parameters has been contradictory. Most studies have focused on examining fundamental frequency. The purpose of this study was to investigate voice use in boys and girls in a day care environment based on the voice parameters fundamental frequency (Hz), vocal intensity (dB SPL), and phonation time (%) and to ascertain whether there were any significant gender differences. Prospective comparative design. The study was conducted in a day care environment where 30 children (17 boys and 13 girls aged 4-5 years) participated. The participants' voices were measured continuously for 4 hours with a voice accumulator that registered fundamental frequency, vocal intensity level, phonation time, and background noise. Mean (standard deviation) fundamental frequency was 310 (22) and 321 (16) Hz, vocal intensity was 93 (4) and 91 (3) dB SPL, and phonation time was 7.7 (2.0)% and 7.6 (2.5)% for boys and girls, respectively. No differences between genders were statistically significant. The finding of no statistically significant gender differences for measurements of voice parameters in a group of children aged 4-5 years in a day care environment is an important finding that contributes to increased knowledge about young boys' and girls' voice use. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  17. VLF propagation measurements in the Canadian Arctic

    NASA Astrophysics Data System (ADS)

    Lauber, Wilfred R.; Bertrand, Jean M.

    1993-05-01

    For the past three years, during a period of high sun spot numbers, propagation measurements were made on the reception of VLF signals in the Canadian Arctic. Between Aug. and Dec. 1989, the received signal strengths were measured on the Canadian Coast Guard icebreaker, John A. MacDonald in the Eastern Canadian Arctic. Between Jul. 1991 and Jun. 1992, the received signal strengths were measured at Nanisivik, Baffin Island. The purposes of this work were to check the accuracy and estimate variances of the Naval Ocean Systems Center's (NOSC) Long Wave Propagation Capability (LWPC) predictions in the Canadian Arctic and to gather ionospheric storm data. In addition, the NOSC data taken at Fort Smith and our data at Nanisivik were used to test the newly developed Longwave Noise Prediction (LNP) program and the CCIR noise predictions, at 21.4 and 24.0 kHz. The results of the work presented and discussed in this paper show that in general the LWPC predicts accurate values of received signal strength in the Canadian Arctic with standard deviations of 1 to 2 dB over several months. Ionospheric storms can gauge the received signal strengths to decrease some 10 dB for a period of several hours or days. However, the effects of these storms are highly dependent on the propagation path. Finally the new LNP atmospheric noise model predicts lower values of noise in the Arctic than the CCIR model and our limited measurements tend to support these lower values.

  18. Landing Gear Noise Prediction and Analysis for Tube-and-Wing and Hybrid-Wing-Body Aircraft

    NASA Technical Reports Server (NTRS)

    Guo, Yueping; Burley, Casey L.; Thomas, Russell H.

    2016-01-01

    Improvements and extensions to landing gear noise prediction methods are developed. New features include installation effects such as reflection from the aircraft, gear truck angle effect, local flow calculation at the landing gear locations, gear size effect, and directivity for various gear designs. These new features have not only significantly improved the accuracy and robustness of the prediction tools, but also have enabled applications to unconventional aircraft designs and installations. Systematic validations of the improved prediction capability are then presented, including parametric validations in functional trends as well as validations in absolute amplitudes, covering a wide variety of landing gear designs, sizes, and testing conditions. The new method is then applied to selected concept aircraft configurations in the portfolio of the NASA Environmentally Responsible Aviation Project envisioned for the timeframe of 2025. The landing gear noise levels are on the order of 2 to 4 dB higher than previously reported predictions due to increased fidelity in accounting for installation effects and gear design details. With the new method, it is now possible to reveal and assess the unique noise characteristics of landing gear systems for each type of aircraft. To address the inevitable uncertainties in predictions of landing gear noise models for future aircraft, an uncertainty analysis is given, using the method of Monte Carlo simulation. The standard deviation of the uncertainty in predicting the absolute level of landing gear noise is quantified and determined to be 1.4 EPNL dB.

  19. Experience with the use of a partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft.

    PubMed

    Birk, Stephanie; Brase, Christoph; Hornung, Joachim

    2014-08-01

    In the further development of alloplastic prostheses for use in middle ear surgery, the Dresden and Cologne University Hospitals, working together with a company, introduced a new partial ossicular replacement prosthesis in 2011. The ball-and-socket joint between the prosthesis and the shaft mimics the natural articulations between the malleus and incus and between the incus and stapes, allowing reaction to movements of the tympanic membrane graft, particularly during the healing process. Retrospective evaluation To reconstruct sound conduction as part of a type III tympanoplasty, partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft was implanted in 60 patients, with other standard partial ossicular replacement prosthesis implanted in 40 patients and 64 patients. Pure-tone audiometry was carried out, on average, 19 and 213 days after surgery. Results of the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft were compared with those of the standard prostheses. Early measurements showed a mean improvement of 3.3 dB in the air-bone gap (ABG) with the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft, giving similar results than the standard implants (6.6 and 6.0 dB, respectively), but the differences were not statistically significant. Later measurements showed a statistically significant improvement in the mean ABG, 11.5 dB, compared with 4.4 dB for one of the standard partial ossicular replacement prosthesis and a tendency of better results to 6.9 dB of the other standard prosthesis. In our patients, we achieved similarly good audiometric results to those already published for the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft. Intraoperative fixation posed no problems, and the postoperative complication rate was low.

  20. Pilot randomised clinical trial of Pascal TargETEd Retinal versus variable fluence PANretinal 20 ms laser in diabetic retinopathy: PETER PAN study.

    PubMed

    Muqit, Mahiul M K; Young, Lorna B; McKenzie, Rod; John, Binu; Marcellino, George R; Henson, David B; Turner, George S; Stanga, Paulo E

    2013-02-01

    To investigate the short-term effects of high-density 20-ms laser on macular thickness using Pascal-targeted retinal photocoagulation (TRP) and reduced fluence/minimally-traumatic panretinal photocoagulation (MT-PRP) compared to standard-intensity PRP (SI-PRP) in proliferative diabetic retinopathy (PDR). Prospective randomised clinical trial. Treatment-naive PDR was treated with single-session 20-ms Pascal 2500 burns photocoagulation randomised to one of three treatment arms (TRP:MT-PRP:SI-PRP). Primary outcome measure was change in central retinal thickness (CRT) on OCT. Secondary outcomes at 4 and 12 weeks post-laser included: OCT peripapillary nerve fibre layer (NFL) thickness; PDR disease regression on Optos angiography; SITA-Std visual fields (VF); and, visual acuity (VA). 30 eyes of 24 patients were studied, ten eyes/arm. At 12 weeks, there were significant reductions in CRT after TRP (9.6 µm; 95% CI, 1.84 to 17.36; p=0.021) and MT-PRP (17.1 µm; 95% CI, 11 to 23.2; p=0.001), versus SI-PRP (+5.9 µm; 95% CI, -6.75 to 18.55; p=0.32). PDR regression was similar between groups (TRP 70%; MT-PRP 70%; SI-PRP 90%; κ=0.76). No significant changes in VA and NFL thickness developed between groups. The VF mean deviation scores increased significantly in all groups at 12 weeks ([TRP, +0.70dB; 95% CI, 0.07 to 1.48; p=0.07], [MT-PRP, +0.63dB; 95% CI, 0.12 to 1.15; p=0.02], [SI-PRP, +1.0dB; 95% CI, 0.19 to 1.74; p=0.02]). There were no laser-related ocular complications. This pilot study reports that high-density 20-ms Pascal TRP and MT-PRP using 2500 burns did not produce increased macular thickness or any ocular adverse events during the short-term.

  1. Automated Smartphone Threshold Audiometry: Validity and Time Efficiency.

    PubMed

    van Tonder, Jessica; Swanepoel, De Wet; Mahomed-Asmail, Faheema; Myburgh, Hermanus; Eikelboom, Robert H

    2017-03-01

    Smartphone-based threshold audiometry with automated testing has the potential to provide affordable access to audiometry in underserved contexts. To validate the threshold version (hearTest) of the validated hearScreen™ smartphone-based application using inexpensive smartphones (Android operating system) and calibrated supra-aural headphones. A repeated measures within-participant study design was employed to compare air-conduction thresholds (0.5-8 kHz) obtained through automated smartphone audiometry to thresholds obtained through conventional audiometry. A total of 95 participants were included in the study. Of these, 30 were adults, who had known bilateral hearing losses of varying degrees (mean age = 59 yr, standard deviation [SD] = 21.8; 56.7% female), and 65 were adolescents (mean age = 16.5 yr, SD = 1.2; 70.8% female), of which 61 had normal hearing and the remaining 4 had mild hearing losses. Threshold comparisons were made between the two test procedures. The Wilcoxon signed-ranked test was used for comparison of threshold correspondence between manual and smartphone thresholds and the paired samples t test was used to compare test time. Within the adult sample, 94.4% of thresholds obtained through smartphone and conventional audiometry corresponded within 10 dB or less. There was no significant difference between smartphone (6.75-min average, SD = 1.5) and conventional audiometry test duration (6.65-min average, SD = 2.5). Within the adolescent sample, 84.7% of thresholds obtained at 0.5, 2, and 4 kHz with hearTest and conventional audiometry corresponded within ≤5 dB. At 1 kHz, 79.3% of the thresholds differed by ≤10 dB. There was a significant difference (p < 0.01) between smartphone (7.09 min, SD = 1.2) and conventional audiometry test duration (3.23 min, SD = 0.6). The hearTest application with calibrated supra-aural headphones provides a cost-effective option to determine valid air-conduction hearing thresholds. American Academy of Audiology

  2. Evapotranspiration of tropical peat swamp forests.

    PubMed

    Hirano, Takashi; Kusin, Kitso; Limin, Suwido; Osaki, Mitsuru

    2015-05-01

    In Southeast Asia, peatland is widely distributed and has accumulated a massive amount of soil carbon, coexisting with peat swamp forest (PSF). The peatland, however, has been rapidly degraded by deforestation, fires, and drainage for the last two decades. Such disturbances change hydrological conditions, typically groundwater level (GWL), and accelerate oxidative peat decomposition. Evapotranspiration (ET) is a major determinant of GWL, whereas information on the ET of PSF is limited. Therefore, we measured ET using the eddy covariance technique for 4-6 years between 2002 and 2009, including El Niño and La Niña events, at three sites in Central Kalimantan, Indonesia. The sites were different in disturbance degree: a PSF with little drainage (UF), a heavily drained PSF (DF), and a drained burnt ex-PSF (DB); GWL was significantly lowered at DF, especially in the dry season. The ET showed a clear seasonal variation with a peak in the mid-dry season and a large decrease in the late dry season, mainly following seasonal variation in net radiation (Rn ). The Rn drastically decreased with dense smoke from peat fires in the late dry season. Annual ET forced to close energy balance for 4 years was 1636 ± 53, 1553 ± 117, and 1374 ± 75 mm yr(-1) (mean ± 1 standard deviation), respectively, at UF, DF, and DB. The undrained PSF (UF) had high and rather stable annual ET, independently of El Niño and La Niña events, in comparison with other tropical rainforests. The minimum monthly-mean GWL explained 80% of interannual variation in ET for the forest sites (UF and DF); the positive relationship between ET and GWL indicates that drainage by a canal decreased ET at DF through lowering GWL. In addition, ET was decreased by 16% at DB in comparison with UF chiefly because of vegetation loss through fires. © 2014 John Wiley & Sons Ltd.

  3. Proposal for fabrication-tolerant SOI polarization splitter-rotator based on cascaded MMI couplers and an assisted bi-level taper

    PubMed Central

    Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan

    2014-01-01

    A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM0 mode into the TE1 mode, which will output as the TE0 mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < −17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology. PMID:25402029

  4. Proposal for fabrication-tolerant SOI polarization splitter-rotator based on cascaded MMI couplers and an assisted bi-level taper.

    PubMed

    Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan

    2014-11-17

    A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM(0) mode into the TE(1) mode, which will output as the TE(0) mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < -17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology.

  5. Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer

    PubMed Central

    Zong, Y.; Datla, R. U.

    1998-01-01

    A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation was measured to be within 0.1 %. The linearity of the detector output was measured over three decades of input power. After applying a simple correction procedure, the detector output was found to deviate less than 0.2 % from linear behavior over this range. The noise equivalent power (NEP) of the bolometer system was 6 × 10−12 W/Hz at the frequency of 80 Hz. The detector output 3 dB roll-off frequency was 200 Hz. The detector output was stable to within ± 0.05 % over a 15 min period. These results demonstrate that the bolometer detector system will serve as an excellent detector for the high accuracy infrared spectrophotometer. PMID:28009364

  6. CEO stabilized frequency comb from a 1-μm Kerr-lens mode-locked bulk Yb:CYA laser.

    PubMed

    Yu, Zijiao; Han, Hainian; Xie, Yang; Peng, Yingnan; Xu, Xiaodong; Wei, Zhiyi

    2016-02-08

    We report the first Kerr-lens mode-locked (KLM) bulk frequency comb in the 1-μm spectral regime. The fundamental KLM Yb:CYA laser is pumped by a low-noise, high-bright 976-nm fiber laser and typically provides 250-mW output power and 57-fs pulse duration. Only 58-mW output pulses were launched into a 1.3-m photonic crystal fiber (PCF) for one octave-spanning supercontinuum generation. Using a simplified collinear f-2f interferometer, the free-running carrier-envelope offset (CEO) frequency was measured to be 42-dB signal-to-noise ratio (SNR) for a 100-kHz resolution and 9.6-kHz full width at half maximum (FWHM) under a 100-Hz resolution. A long-term CEO control at 23 MHz was ultimately realized by feeding the phase error signal to the pump power of the oscillator. The integrated phase noise (IPN) of the locked CEO was measured to be 316 mrad with an integrated range from 1 Hz to 10 MHz. The standard deviation and Allan deviation for more than 4-hour recording are 1.6 mHz and 5.6 × 10(-18) (for 1-s gate time), respectively. This is, to the best of our knowledge, the best stability achieved among the 1-μm solid-state frequency combs.

  7. How do we assign punishment? The impact of minimal and maximal standards on the evaluation of deviants.

    PubMed

    Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven

    2010-09-01

    To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.

  8. Repeatability of normal multifocal VEP: implications for detecting progression.

    PubMed

    Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Johnson, Chris A

    2006-04-01

    To assess the repeatability of the multifocal visual evoked potential (mfVEP) and to compare it with the repeatability of standard automated perimetry (SAP) in the same group of 50 normal controls retested after 1 year. Our second aim was to assess the repeatability of false alarm rates determined previously for the mfVEP using various cluster criteria. Fifty individuals with normal vision participated in this study (33 females and 17 males). The age range was 26.7 to 77.9 years and the group average age (+/- SD) was 51.4 (+/- 12.1) years. Pattern-reversal mfVEPs were obtained using a dartboard stimulus pattern in VERIS and two 8-minute runs per eye were averaged. The average number of days between the first and second mfVEP tests was 378 (+/- 58). SAP visual fields were obtained within 17.4 (+/- 20.3) days of the mfVEP using the SITA-standard threshold algorithm. Repeatability of mfVEPs and SAP total deviation values were evaluated by calculating point-wise limits of agreement (LOA). Specificity (1-false alarm rate) was evaluated for a range of cluster criteria, whereby the number and probability level of the points defining a cluster were varied. Point-wise LOA for the mfVEP signal-to-noise ratio (SNR) ranged from 2.0 to 4.3 dB, with an average of 2.9 dB across all 60 locations. For SAP, LOA ranged from 2.4 to 8.9 dB, with an average of 4.0 dB (excluding the points immediately above and below the blind spot). Clusters of abnormal points were not likely to repeat on either mfVEP or SAP. When an mfVEP abnormality was defined as the repeat presence (confirmation) of a 3-point (P < 0.05) cluster anywhere within a single hemifield, only 1 (of 200) monocular hemifield was deemed abnormal. Although the LOA of the mfVEP were similar throughout the field, the limited dynamic range of SNR at superior field locations will limit the ability to follow progression in "depth" at those locations. Repeatability of the mfVEP was slightly better than SAP visual fields in this group of controls with a 1-year retest interval. This suggests that progression in early stages should be more easily detectable by mfVEP. However, in certain field locations (eg, superior periphery), the relatively more narrow dynamic range of the SNR of the mfVEP may limit detection of progression to just 1 event. Confirmation of a 3-point cluster abnormality is highly suggestive of a true defect on the mfVEP.

  9. Characterization of sulfur and nitrogen compounds in Brazilian petroleum derivatives using ionic liquid capillary columns in comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection.

    PubMed

    Cappelli Fontanive, Fernando; Souza-Silva, Érica Aparecida; Macedo da Silva, Juliana; Bastos Caramão, Elina; Alcaraz Zini, Claudia

    2016-08-26

    Diesel and naphtha samples were analyzed using ionic liquid (IL) columns to evaluate the best column set for the investigation of organic sulfur compounds (OSC) and nitrogen(N)-containing compounds analyses with comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry detector (GC×GC/TOFMS). Employing a series of stationary phase sets, namely DB-5MS/DB-17, DB-17/DB-5MS, DB-5MS/IL-59, and IL-59/DB-5MS, the following parameters were systematically evaluated: number of tentatively identified OSC, 2D chromatographic space occupation, number of polyaromatic hydrocarbons (PAH) and OSC co-elutions, and percentage of asymmetric peaks. DB-5MS/IL-59 was chosen for OSC analysis, while IL59/DB-5MS was chosen for nitrogen compounds, as each stationary phase set provided the best chromatographic efficiency for these two classes of compounds, respectively. Most compounds were tentatively identified by Lee and Van den Dool and Kratz retention indexes, and spectra-matching to library. Whenever available, compounds were also positively identified via injection of authentic standards. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports

    PubMed Central

    Jiao, Boshen; Zafari, Zafar; Will, Brian; Ruggeri, Kai

    2017-01-01

    Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB) averaged over a 24-h ‘day and night’ period (DNL) in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA) as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained). Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value. PMID:29207473

  11. The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports.

    PubMed

    Jiao, Boshen; Zafari, Zafar; Will, Brian; Ruggeri, Kai; Li, Shukai; Muennig, Peter

    2017-12-02

    Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB) averaged over a 24-h 'day and night' period (DNL) in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA) as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained). Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value.

  12. Relevance Vector Machine and Support Vector Machine Classifier Analysis of Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements

    PubMed Central

    Bowd, Christopher; Medeiros, Felipe A.; Zhang, Zuohua; Zangwill, Linda M.; Hao, Jiucang; Lee, Te-Won; Sejnowski, Terrence J.; Weinreb, Robert N.; Goldbaum, Michael H.

    2010-01-01

    Purpose To classify healthy and glaucomatous eyes using relevance vector machine (RVM) and support vector machine (SVM) learning classifiers trained on retinal nerve fiber layer (RNFL) thickness measurements obtained by scanning laser polarimetry (SLP). Methods Seventy-two eyes of 72 healthy control subjects (average age = 64.3 ± 8.8 years, visual field mean deviation =−0.71 ± 1.2 dB) and 92 eyes of 92 patients with glaucoma (average age = 66.9 ± 8.9 years, visual field mean deviation =−5.32 ± 4.0 dB) were imaged with SLP with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, San Diego, CA). RVM and SVM learning classifiers were trained and tested on SLP-determined RNFL thickness measurements from 14 standard parameters and 64 sectors (approximately 5.6° each) obtained in the circumpapillary area under the instrument-defined measurement ellipse (total 78 parameters). Tenfold cross-validation was used to train and test RVM and SVM classifiers on unique subsets of the full 164-eye data set and areas under the receiver operating characteristic (AUROC) curve for the classification of eyes in the test set were generated. AUROC curve results from RVM and SVM were compared to those for 14 SLP software-generated global and regional RNFL thickness parameters. Also reported was the AUROC curve for the GDx VCC software-generated nerve fiber indicator (NFI). Results The AUROC curves for RVM and SVM were 0.90 and 0.91, respectively, and increased to 0.93 and 0.94 when the training sets were optimized with sequential forward and backward selection (resulting in reduced dimensional data sets). AUROC curves for optimized RVM and SVM were significantly larger than those for all individual SLP parameters. The AUROC curve for the NFI was 0.87. Conclusions Results from RVM and SVM trained on SLP RNFL thickness measurements are similar and provide accurate classification of glaucomatous and healthy eyes. RVM may be preferable to SVM, because it provides a Bayesian-derived probability of glaucoma as an output. These results suggest that these machine learning classifiers show good potential for glaucoma diagnosis. PMID:15790898

  13. Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 1: January

    NASA Astrophysics Data System (ADS)

    Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.

    1989-07-01

    The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of January. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Mean density standard deviation (all for 13 levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.

  14. mzDB: A File Format Using Multiple Indexing Strategies for the Efficient Analysis of Large LC-MS/MS and SWATH-MS Data Sets*

    PubMed Central

    Bouyssié, David; Dubois, Marc; Nasso, Sara; Gonzalez de Peredo, Anne; Burlet-Schiltz, Odile; Aebersold, Ruedi; Monsarrat, Bernard

    2015-01-01

    The analysis and management of MS data, especially those generated by data independent MS acquisition, exemplified by SWATH-MS, pose significant challenges for proteomics bioinformatics. The large size and vast amount of information inherent to these data sets need to be properly structured to enable an efficient and straightforward extraction of the signals used to identify specific target peptides. Standard XML based formats are not well suited to large MS data files, for example, those generated by SWATH-MS, and compromise high-throughput data processing and storing. We developed mzDB, an efficient file format for large MS data sets. It relies on the SQLite software library and consists of a standardized and portable server-less single-file database. An optimized 3D indexing approach is adopted, where the LC-MS coordinates (retention time and m/z), along with the precursor m/z for SWATH-MS data, are used to query the database for data extraction. In comparison with XML formats, mzDB saves ∼25% of storage space and improves access times by a factor of twofold up to even 2000-fold, depending on the particular data access. Similarly, mzDB shows also slightly to significantly lower access times in comparison with other formats like mz5. Both C++ and Java implementations, converting raw or XML formats to mzDB and providing access methods, will be released under permissive license. mzDB can be easily accessed by the SQLite C library and its drivers for all major languages, and browsed with existing dedicated GUIs. The mzDB described here can boost existing mass spectrometry data analysis pipelines, offering unprecedented performance in terms of efficiency, portability, compactness, and flexibility. PMID:25505153

  15. Comparing Standard Deviation Effects across Contexts

    ERIC Educational Resources Information Center

    Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.

    2017-01-01

    Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…

  16. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    PubMed Central

    Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326

  17. Standardized Testing Capabilities at U.S. Navy Transducer Repair Facilities

    DTIC Science & Technology

    1972-08-01

    The following acoustical and electrical tests can be performed at the TRFs by the use of an AN/FQM-lO(V) Sonar Test Set, a. Low level impedance...It fits into the sub- system as shown in Fig 2-2. A switch located at the preamplifier is used to select either high or low power operation. The...may also be selected. 2.6.2 Signal Amplification. A low noise differential premnplifier with selectable gains from -20 dB to +60 dB in 10 dB steps is

  18. Blood pressure variability in man: its relation to high blood pressure, age and baroreflex sensitivity.

    PubMed

    Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A

    1980-12-01

    1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.

  19. Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 7: July

    NASA Astrophysics Data System (ADS)

    Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.

    1989-07-01

    The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of July. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.

  20. Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 10: October

    NASA Astrophysics Data System (ADS)

    Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.

    1989-07-01

    The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of October. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point/standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.

  1. Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 3: March

    NASA Astrophysics Data System (ADS)

    Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.

    1989-11-01

    The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of March. Included are global analyses of: (1) Mean Temperature Standard Deviation; (2) Mean Geopotential Height Standard Deviation; (3) Mean Density Standard Deviation; (4) Height and Vector Standard Deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean Dew Point Standard Deviation for levels 1000 through 30 mb; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.

  2. Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 2: February

    NASA Astrophysics Data System (ADS)

    Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.

    1989-09-01

    The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of February. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.

  3. Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 4: April

    NASA Astrophysics Data System (ADS)

    Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.

    1989-07-01

    The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of April. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.

  4. Precision analysis for standard deviation measurements of immobile single fluorescent molecule images.

    PubMed

    DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M

    2010-03-29

    Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.

  5. Evaluating standard airborne sound insulation measures in terms of annoyance, loudness, and audibility ratings.

    PubMed

    Park, H K; Bradley, J S

    2009-07-01

    This paper reports the results of an evaluation of the merits of standard airborne sound insulation measures with respect to subjective ratings of the annoyance and loudness of transmitted sounds. Subjects listened to speech and music sounds modified to represent transmission through 20 different walls with sound transmission class (STC) ratings from 34 to 58. A number of variations in the standard measures were also considered. These included variations in the 8-dB rule for the maximum allowed deficiency in the STC measure as well as variations in the standard 32-dB total allowed deficiency. Several spectrum adaptation terms were considered in combination with weighted sound reduction index (R(w)) values as well as modifications to the range of included frequencies in the standard rating contour. A STC measure without an 8-dB rule and an R(w) rating with a new spectrum adaptation term were better predictors of annoyance and loudness ratings of speech sounds. R(w) ratings with one of two modified C(tr) spectrum adaptation terms were better predictors of annoyance and loudness ratings of transmitted music sounds. Although some measures were much better predictors of responses to one type of sound than were the standard STC and R(w) values, no measure was remarkably improved for predicting annoyance and loudness ratings of both music and speech sounds.

  6. Foveal threshold and photoreceptor integrity for prediction of visual acuity after intravitreal aflibercept on age-related macular degeneration.

    PubMed

    Sakai, Tsutomu; Okude, Sachiyo; Tsuneoka, Hiroshi

    2018-01-01

    To determine whether baseline foveal threshold and photoreceptor integrity can predict best-corrected visual acuity (BCVA) at 12 months after intravitreal aflibercept (IVA) therapy in eyes with neovascular age-related macular degeneration (AMD). We evaluated 25 eyes of 25 patients with treatment-naïve neovascular AMD who received IVA once a month for 3 months, followed by once every 2 months for 8 months. BCVA, integrity of the external limiting membrane (ELM) or the ellipsoid zone (EZ) of the photoreceptors, and retinal sensitivity were determined before (baseline) and at 6 and 12 months after initial IVA. The average threshold foveal sensitivity and mean deviation within the central 10° were determined by Humphrey central 10-2 perimetry. Correlations between BCVA at 12 months and integrity of the ELM or EZ, foveal threshold, and mean deviation at each visit were determined. At 12 months, BCVA improved significantly from 0.20±0.23 to 0.10±0.22 logMAR (logarithm of the minimum angle of resolution) units, and foveal threshold and mean deviation improved significantly from 29.0±5.1 and -3.38±3.10 dB to 32.6±3.2 and -1.64±2.10 dB, respectively ( P =0.0009 and P =0.0021). At baseline, both foveal threshold and integrity of the ELM were significantly correlated with BCVA at 12 months ( P =0.0428 and P =0.0275). These results indicate that both integrity of the ELM and foveal threshold at baseline can predict BCVA after treatment for neovascular AMD. There is a possibility that these parameters can predict the efficacy of IVA in each case.

  7. Current patch test results in consecutive patients with, and chemical analysis of, disperse blue (DB) 106, DB 124, and the mix of DB 106 and 124.

    PubMed

    Uter, Wolfgang; Hildebrandt, Stephan; Geier, Johannes; Schnuch, Axel; Lessmann, Holger

    2007-10-01

    Disperse blue (DB) 106 and 124 are important textile dye allergens. However, the dye raw material is impure, leading to uncertainty regarding the actual patch test (PT) concentration. To examine, (i) the allergen content of previously and currently used DB 106 and 124 and a respective mix, and (ii) the frequency of positive PT reactions to the DB 106/124 mix and to the single compounds in consecutive PT patients. High performance liquid chromatography (HPLC) analysis and purification of DB 106 and 124, respectively. Descriptive analysis of PT data from the Information network of departments of dermatology obtained between January 2003 and December 2005. Retrospectively, 2 batches of the DB 106/124 mix proved to contain an amount of allergen different to the 1 declared (based on information of suppliers of raw material). However, since February 2005, DB 106 and 124, respectively, are available at a reliable concentration of 0.3% petrolatum. In 2005, the prevalence of positive PT reactions to both the mix (0.89%) and the single constituents combined (0.56%) did not qualify them for inclusion in the standard series. Quality control, providing accurate test concentrations of allergens based on technical grade purity raw materials is necessary for valid diagnosis of contact allergy and comparable epidemiological data.

  8. Intratumoral heterogeneity on dedicated breast positron emission tomography predicts malignancy grade of breast cancer.

    PubMed

    Masumoto, Norio; Kadoya, Takayuki; Sasada, Shinsuke; Emi, Akiko; Arihiro, Koji; Okada, Morihito

    2018-05-19

    Dedicated breast positron emission tomography (DbPET) provides detailed high-resolution images and can detect intratumoral heterogeneity using 18 F-fluorodeoxyglucose (FDG). We aimed to evaluate the correlation between FDG uptake on DbPET and the clinicopathological features of breast cancer, particularly those with an intratumoral heterogeneous distribution of FDG on DbPET. We evaluated 195 consecutive patients with invasive breast cancer who underwent preoperative whole-body PET (WBPET) and DbPET concurrently between January 2016 and March 2017. The relationships between clinicopathological factors and the maximum standard uptake values (SUVmax) of DbPET and WBPET, including clinical stage, nuclear grade, Ki67 proliferation index, estrogen receptor (ER) and human epidermal growth factor receptor type 2 (HER2) statuses, and the intratumoral heterogeneous distribution of FDG on DbPET, were evaluated. The SUVmax of DbPET was significantly correlated with clinical T stage, N stage, nuclear grade, and Ki67 proliferation index (all p < 0.001) as well as the ER (p = 0.006) and HER2 (p = 0.040) statuses. Intratumoral heterogeneous distribution of FDG on DbPET was significantly related with high nuclear grade (p = 0.016) and high Ki67 proliferation index (p = 0.015) but not with clinical T stage, N stage, and ER and HER2 statuses. The SUVmax of DbPET correlates with clinicopathological factors and also WBPET does. In addition, intratumoral heterogeneity on DbPET provides predictive value for malignancy grade and could inform therapeutic decisions.

  9. Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.

    PubMed

    Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Patterson, Emily; Jamil, Annisa; Mansberger, Steven L; Cioffi, George A; Johnson, Chris A

    2007-03-01

    To compare the diagnostic performance of multifocal visual evoked potential (mfVEP) and standard automated perimetry (SAP), in eyes with high-risk ocular hypertension or early glaucoma. Both eyes of 185 individuals with high-risk ocular hypertension or early glaucoma were evaluated. Subjects ranged in age from 37 to 87 (mean +/- SD: 61 +/- 11 years). Pattern-reversal mfVEPs were obtained by using VERIS (Electro-Diagnostic Imaging, San Mateo, CA) with a four-electrode array and were analyzed with custom software. SAP visual fields (SITA-standard; Carl Zeiss Meditec, Inc., Dublin, CA) were obtained within 22.3 +/- 27.0 days of the mfVEP. Stereo disc photographs and Heidelberg Retina Tomograph (HRT) images were obtained during one visit, which was within 24.8 +/- 50.4 days of the mfVEP and 33.1 +/- 62.9 days of the SAP visual field. Abnormalities on the mfVEP were defined by using a variety of cluster criteria: SAP with pattern standard deviation (PSD) P

  10. Doppler-broadened NICE-OHMS beyond the cavity-limited weak absorption condition - I. Theoretical description

    NASA Astrophysics Data System (ADS)

    Ma, Weiguang; Silander, Isak; Hausmaninger, Thomas; Axner, Ove

    2016-01-01

    Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) is conventionally described by an expression (here referred to as the CONV expression) that is restricted to the case when the single-pass absorbance, α0L, is much smaller than the empty cavity losses, π/F [here termed the conventional cavity-limited weak absorption (CCLWA) condition]. This limits the applicability of the technique, primarily its dynamic range and calibration capability. To remedy this, this work derives extended descriptions of Db NICE-OHMS that are not restricted to the CCLWA condition. First, the general principles of Db NICE-OHMS are scrutinized in some detail. Based solely upon a set of general assumptions, predominantly that it is appropriate to linearize the Beer-Lambert law, that the light is modulated to a triplet, and that the Pound-Drever-Hall sidebands are fully reflected, a general description of Db NICE-OHMS that is not limited to any specific restriction on α0L vs. π/F, here referred to as the FULL description, is derived. However, this description constitutes a set of equations to which no closed form solution has been found. Hence, it needs to be solved numerically (by iterations), which is inconvenient. To circumvent this, for the cases when α0L<π/F but without the requirement that the stronger CCLWA condition needs to be fulfilled, a couple of simplified extended expressions that are expressible in closed analytical form, referred to as the extended locking and extended transmission description, ELET, and the extended locking and full transmission description, ELFT, have been derived. An analysis based on simulations validates the various descriptions and assesses to which extent they agree. It is shown that in the CCLWA limit, all extended descriptions revert to the CONV expression. The latter one deviates though from the extended ones for α0L around and above 0.1π/F. The two simplified extended descriptions agree with the FULL description for a larger range of α0 L than the CONV expression, viz. for the ELET description for α0L up to 0.3π/F and for ELFT for α0L up to 0.6 or 1.0 π/F (depending on the mode of detection). It is then demonstrated that the conventional view of Db NICE-OHMS, which states that the out-of-phase and the in-phase signals can be referred to as a pure absorption and dispersion signal, respectively, breaks down when the CCLWA condition does not hold. In this case, the out-of-phase signal is additionally affected by the phase shifts of the laser components (i.e. dispersion) while the in-phase signal is also influenced by their attenuation. Access to new descriptions broadens considerably the dynamic range of Db NICE-OHMS and facilitates calibration using standard references samples, and thereby its applicability.

  11. P³DB 3.0: From plant phosphorylation sites to protein networks.

    PubMed

    Yao, Qiuming; Ge, Huangyi; Wu, Shangquan; Zhang, Ning; Chen, Wei; Xu, Chunhui; Gao, Jianjiong; Thelen, Jay J; Xu, Dong

    2014-01-01

    In the past few years, the Plant Protein Phosphorylation Database (P(3)DB, http://p3db.org) has become one of the most significant in vivo data resources for studying plant phosphoproteomics. We have substantially updated P(3)DB with respect to format, new datasets and analytic tools. In the P(3)DB 3.0, there are altogether 47 923 phosphosites in 16 477 phosphoproteins curated across nine plant organisms from 32 studies, which have met our multiple quality standards for acquisition of in vivo phosphorylation site data. Centralized by these phosphorylation data, multiple related data and annotations are provided, including protein-protein interaction (PPI), gene ontology, protein tertiary structures, orthologous sequences, kinase/phosphatase classification and Kinase Client Assay (KiC Assay) data--all of which provides context for the phosphorylation event. In addition, P(3)DB 3.0 incorporates multiple network viewers for the above features, such as PPI network, kinase-substrate network, phosphatase-substrate network, and domain co-occurrence network to help study phosphorylation from a systems point of view. Furthermore, the new P(3)DB reflects a community-based design through which users can share datasets and automate data depository processes for publication purposes. Each of these new features supports the goal of making P(3)DB a comprehensive, systematic and interactive platform for phosphoproteomics research.

  12. High-fat, carbohydrate-free diet markedly aggravates obesity but prevents beta-cell loss and diabetes in the obese, diabetes-susceptible db/db strain.

    PubMed

    Mirhashemi, Farshad; Kluth, Oliver; Scherneck, Stephan; Vogel, Heike; Kluge, Reinhart; Schurmann, Annette; Joost, Hans-Georg; Neschen, Susanne

    2008-01-01

    We have previously reported that a high-fat, carbohydrate-free diet prevents diabetes and beta-cell destruction in the New Zealand Obese (NZO) mouse strain. Here we investigated the effect of diets with and without carbohydrates on obesity and development of beta-cell failure in a second mouse model of type 2 diabetes, the db/db mouse. When kept on a carbohydrate-containing standard (SD; with (w/w) 5.1, 58.3, and 17.6% fat, carbohydrates and protein, respectively) or high-fat diet (HFD; 14.6, 46.7 and 17.1%), db/db mice developed severe diabetes (blood glucose >20 mmol/l, weight loss, polydipsia and polyurea) associated with a selective loss of pancreatic beta-cells, reduced GLUT2 expression in the remaining beta-cells, and reduced plasma insulin levels. In contrast, db/db mice kept on a high-fat, carbohydrate-free diet (CFD; with 30.2 and 26.4% (w/w) fat or protein) did not develop diabetes and exhibited near-normal, hyperplastic islets in spite of a morbid obesity (fat content >60%) associated with hyperinsulinaemia. These data indicate that in genetically different mouse models of obesity-associated diabetes, obesity and dietary fat are not sufficient, and dietary carbohydrates are required, for beta-cell destruction.

  13. Noise pollution in intensive care units and emergency wards.

    PubMed

    Khademi, Gholamreza; Roudi, Masoumeh; Shah Farhat, Ahmad; Shahabian, Masoud

    2011-01-01

    The improvement of technology has increased noise levels in hospital Wards to higher than international standard levels (35-45 dB). Higher noise levels than the maximum level result in patient's instability and dissatisfaction. Moreover, it will have serious negative effects on the staff's health and the quality of their services. The purpose of this survey is to analyze the level of noise in intensive care units and emergency wards of the Imam Reza Teaching Hospital, Mashhad. This research was carried out in November 2009 during morning shifts between 7:30 to 12:00. Noise levels were measured 10 times at 30-minute intervals in the nursing stations of 10 wards of the emergency, the intensive care units, and the Nephrology and Kidney Transplant Departments of Imam Reza University Hospital, Mashhad. The noise level in the nursing stations was tested for both the maximum level (Lmax) and the equalizing level (Leq). The research was based on the comparison of equalizing levels (Leq) because maximum levels were unstable. In our survey the average level (Leq) in all wards was much higher than the standard level. The maximum level (Lmax) in most wards was 85-86 dB and just in one measurement in the Internal ICU reached 94 dB. The average level of Leq in all wards was 60.2 dB. In emergency units, it was 62.2 dB, but it was not time related. The highest average level (Leq) was measured at 11:30 AM and the peak was measured in the Nephrology nursing station. The average levels of noise in intensive care units and also emergency wards were more than the standard levels and as it is known these wards have vital roles in treatment procedures, so more attention is needed in this area.

  14. [Comparing the ranges of defect measured with standard white on white and Pulsar perimetries].

    PubMed

    González de la Rosa, M; González-Hernández, M; García-Feijoo, J; Sánchez Méndez, M; García-Sánchez, J

    2011-04-01

    Normal thresholds on Pulsar perimetry fall faster than those of standard perimetry in the peripheral visual field. Two related studies were performed. Firstly, the frequency distributions of glaucoma defects on standard automated perimetry (SAP) and the relationship of the centre and periphery (Study A) were studied first, followed by an attempt to establish the limits of pulsar perimetry (Study B). A: frequency of defects was calculated in 78.663 SAP perimetries (G1-TOP, Octopus 1-2-3, Haag-Streit). Study B: 204 eyes with mean defect (MD-SAP) lower than 9 dB were examined 8.92 ± 4.19 times with SAP (TOP-32, Octopus 311) and temporal modulation perimetry (T30W, Pulsar Perimeter, Haag-Streit). Study A: 50.7% of the SAP examinations showed MD values lower than 9 dB and 32.7% bellow 6 dB. The MD correlation of the central 20° with the MD of the most peripheral points was r=0.933. Study B: in cases with MD-TOP-32 lower than 6 dB, SAP had the maximum possibility of detecting defect in 0.02% of points and Pulsar in 0.29%. In subjects with MD-TOP-32 between 6 and 9 dB frequencies were 0.38% in SAP and 3.5% in Pulsar (5.1% for eccentricities higher than 20°). Pulsar allows detecting defects, without range limitations, in the initial half of SAP frequencies expected on glaucoma patients. In order to study the progression of deeper defects the examination should focus on the central points, where the dynamic range of both systems is more equivalent. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  15. Understanding disparities among diagnostic technologies in glaucoma.

    PubMed

    De Moraes, Carlos Gustavo V; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2012-07-01

    To investigate causes of disagreement among 3 glaucoma diagnostic techniques: standard automated achromatic perimetry (SAP), the multifocal visual evoked potential technique (mfVEP), and optical coherence tomography (OCT). In a prospective cross-sectional study, 138 eyes of 69 patients with glaucomatous optic neuropathy were tested using SAP, the mfVEP, and OCT. Eyes with the worse and better mean deviations (MDs) were analyzed separately. If the results of 2 tests were consistent for the presence of an abnormality in the same topographic site, that abnormality was considered a true glaucoma defect. If a third test missed that abnormality (false-negative result), the reasons for disparity were investigated. Eyes with worse MD (mean [SD], -6.8 [8.0] dB) had better agreements among tests than did eyes with better MD (-2.5 [3.5] dB, P<.01). For the 94 of 138 hemifields with abnormalities of the more advanced eyes, the 3 tests were consistent in showing the same hemifield abnormality in 50 hemifields (53%), and at least 2 tests were abnormal in 65 of the 94 hemifields (69%). The potential explanations for the false-negative results fell into 2 general categories: inherent limitations of each technique to detect distinct features of glaucoma and individual variability and the distribution of normative values used to define statistically significant abnormalities. All the cases of disparity could be explained by known limitations of each technique and interindividual variability, suggesting that the agreement among diagnostic tests may be better than summary statistics suggest and that disagreements between tests do not indicate discordance in the structure-function relationship.

  16. The European Classical Swine Fever Virus Database: Blueprint for a Pathogen-Specific Sequence Database with Integrated Sequence Analysis Tools

    PubMed Central

    Postel, Alexander; Schmeiser, Stefanie; Zimmermann, Bernd; Becher, Paul

    2016-01-01

    Molecular epidemiology has become an indispensable tool in the diagnosis of diseases and in tracing the infection routes of pathogens. Due to advances in conventional sequencing and the development of high throughput technologies, the field of sequence determination is in the process of being revolutionized. Platforms for sharing sequence information and providing standardized tools for phylogenetic analyses are becoming increasingly important. The database (DB) of the European Union (EU) and World Organisation for Animal Health (OIE) Reference Laboratory for classical swine fever offers one of the world’s largest semi-public virus-specific sequence collections combined with a module for phylogenetic analysis. The classical swine fever (CSF) DB (CSF-DB) became a valuable tool for supporting diagnosis and epidemiological investigations of this highly contagious disease in pigs with high socio-economic impacts worldwide. The DB has been re-designed and now allows for the storage and analysis of traditionally used, well established genomic regions and of larger genomic regions including complete viral genomes. We present an application example for the analysis of highly similar viral sequences obtained in an endemic disease situation and introduce the new geographic “CSF Maps” tool. The concept of this standardized and easy-to-use DB with an integrated genetic typing module is suited to serve as a blueprint for similar platforms for other human or animal viruses. PMID:27827988

  17. Exploring Students' Conceptions of the Standard Deviation

    ERIC Educational Resources Information Center

    delMas, Robert; Liu, Yan

    2005-01-01

    This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…

  18. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  19. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  20. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  1. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  2. Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation

    ERIC Educational Resources Information Center

    Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann

    2017-01-01

    This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…

  3. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  4. 7 CFR 801.6 - Tolerances for moisture meters.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat Mid ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat High ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat...

  5. [Assessment of the macula function by static perimetry, microperimetry and rarebit perimetry in patients suffering from dry age related macular degeneration].

    PubMed

    Nowomiejska, Katarzyna; Oleszczuk, Agnieszka; Zubilewicz, Anna; Krukowski, Jacek; Mańkowska, Anna; Rejdak, Robert; Zagórski, Zbigniew

    2007-01-01

    To compare the visual field results obtained by static perimetry, microperimetry and rabbit perimetry in patients suffering from dry age related macular degeneration (AMD). Fifteen eyes with dry AMD (hard or soft macula drusen and RPE disorders) were enrolled into the study. Static perimetry was performed using M2 macula program included in Octopus 101 instrument. Microperimetry was performed using macula program (14-2 threshold, 10dB) within 10 degrees of the central visual field. The fovea program within 4 degrees was used while performing rarebit perimetry. The mean sensitivity was significantly lower (p<0.001) during microperimetry (13.5 dB) comparing to static perimetry (26.7 dB). The mean deviation was significantly higher (p<0.001) during microperimetry (-6.32 dB) comparing to static perimetry (-3.11 dB). The fixation was unstable in 47% and eccentric in 40% while performing microperimetry. The median of the "mean hit rate" in rarebit perimetry was 90% (range 40-100%). The mean examination duration was 6.5 min. in static perimetry, 10.6 min. in microperimetry and 5,5 min. in rarebit perimetry (p<0.001). Sensitivity was 30%, 53% and 93% respectively. The visual field defects obtained by microperimetry were more pronounced than those obtained by static perimetry. Microperimetry was the most sensitive procedure although the most time-consuming. Microperimetry enables the control of the fixation position and stability, that is not possible using the remaining methods. Rarebit perimetry revealed slight reduction of the integrity of neural architecture of the retina. Microperimetry and rarebit perimetry provide more information in regard to the visual function than static perimetry, thus are the valuable method in the diagnosis of dry AMD.

  6. Ultra-high-extinction-ratio 2 × 2 silicon optical switch with variable splitter.

    PubMed

    Suzuki, Keijiro; Cong, Guangwei; Tanizawa, Ken; Kim, Sang-Hun; Ikeda, Kazuhiro; Namiki, Shu; Kawashima, Hitoshi

    2015-04-06

    We demonstrate a record-high extinction-ratio of 50.4 dB in a 2 × 2 silicon Mach-Zehnder switch equipped with a variable splitter as the front 3-dB splitter. The variable splitter is adjusted to compensate for the splitting-ratio mismatch between the front and rear 3-dB splitters. The high extinction ratio does not rely on waveguide crossings and meets a strong demand in applications to multiport circuit switches. Large fabrication tolerance will make the high extinction ratio compatible with a volume production with standard complementary metal-oxide semiconductor fabrication facilities.

  7. Managing Attribute—Value Clinical Trials Data Using the ACT/DB Client—Server Database System

    PubMed Central

    Nadkarni, Prakash M.; Brandt, Cynthia; Frawley, Sandra; Sayward, Frederick G.; Einbinder, Robin; Zelterman, Daniel; Schacter, Lee; Miller, Perry L.

    1998-01-01

    ACT/DB is a client—server database application for storing clinical trials and outcomes data, which is currently undergoing initial pilot use. It stores most of its data in entity—attribute—value form. Such data are segregated according to data type to allow indexing by value when possible, and binary large object data are managed in the same way as other data. ACT/DB lets an investigator design a study rapidly by defining the parameters (or attributes) that are to be gathered, as well as their logical grouping for purposes of display and data entry. ACT/DB generates customizable data entry. The data can be viewed through several standard reports as well as exported as text to external analysis programs. ACT/DB is designed to encourage reuse of parameters across multiple studies and has facilities for dictionary search and maintenance. It uses a Microsoft Access client running on Windows 95 machines, which communicates with an Oracle server running on a UNIX platform. ACT/DB is being used to manage the data for seven studies in its initial deployment. PMID:9524347

  8. PharmDB-K: Integrated Bio-Pharmacological Network Database for Traditional Korean Medicine

    PubMed Central

    Lee, Ji-Hyun; Park, Kyoung Mii; Han, Dong-Jin; Bang, Nam Young; Kim, Do-Hee; Na, Hyeongjin; Lim, Semi; Kim, Tae Bum; Kim, Dae Gyu; Kim, Hyun-Jung; Chung, Yeonseok; Sung, Sang Hyun; Surh, Young-Joon; Kim, Sunghoon; Han, Byung Woo

    2015-01-01

    Despite the growing attention given to Traditional Medicine (TM) worldwide, there is no well-known, publicly available, integrated bio-pharmacological Traditional Korean Medicine (TKM) database for researchers in drug discovery. In this study, we have constructed PharmDB-K, which offers comprehensive information relating to TKM-associated drugs (compound), disease indication, and protein relationships. To explore the underlying molecular interaction of TKM, we integrated fourteen different databases, six Pharmacopoeias, and literature, and established a massive bio-pharmacological network for TKM and experimentally validated some cases predicted from the PharmDB-K analyses. Currently, PharmDB-K contains information about 262 TKMs, 7,815 drugs, 3,721 diseases, 32,373 proteins, and 1,887 side effects. One of the unique sets of information in PharmDB-K includes 400 indicator compounds used for standardization of herbal medicine. Furthermore, we are operating PharmDB-K via phExplorer (a network visualization software) and BioMart (a data federation framework) for convenient search and analysis of the TKM network. Database URL: http://pharmdb-k.org, http://biomart.i-pharm.org. PMID:26555441

  9. Long-period grating fabricated by periodically tapering standard single-mode fiber.

    PubMed

    Shao, Li-Yang; Zhao, Jian; Dong, Xinyong; Tam, H Y; Lu, C; He, Sailing

    2008-04-01

    We fabricated an asymmetric long-period grating (LPG) by periodically tapering a section of standard single-mode fiber using a resistive filament heating. The LPG exhibits large peak transmission attenuation of -30.31 dB with only 22 periods in a 1.0 cm long optical fiber and possesses unique characteristics for sensing applications. The bending and strain sensitivities are 1.74 nm m and 1.11 pm/mu epsilon, respectively. The polarization dependent loss is large, up to 11.65 dB, which is caused by an asymmetric index profile in the cross section of the tapered LPG.

  10. A novel five-wire micro anemometer with 3D directionality for low speed air flow detection and acoustic particle velocity detecting capability

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Chang, Wenhan; Gao, Chengchen; Hao, Yilong

    2018-04-01

    In this paper, a novel five-wire micro-fabricated anemometer with 3D directionality based on calorimetric principle is proposed, which is capable of measuring low speed airflow. This structure is realized by vertically bonding two different dies, which can be fabricated on the same wafer resulting in a simple fabrication process. Experiments on speed lower than 200 mm s-1 are conducted, showing good repeatability and directionality. The speed of airflow is controlled by the volumetric flow rate. The measured velocity sensitivity is 9.4 mV · s m-1, with relative direction sensitivity of 37.1 dB. The deviation between the expected and the measured directivity is analyzed by both theories and simulations. A correction procedure is proposed and turns out to be useful to eliminate this deviation. To further explore the potential of our device, we expose it to acoustic plane waves in a standing wave tube, showing consistent planar directivity of figure of eight. The measured velocity sensitivity at 1 kHz and 120 dBC is 4.4 mV · s m-1, with relative direction sensitivity of 27.0 dB. By using the correction method proposed above, the maximum angle error is about  ±2°, showing its good directionality accuracy.

  11. The low-frequency sound power measuring technique for an underwater source in a non-anechoic tank

    NASA Astrophysics Data System (ADS)

    Zhang, Yi-Ming; Tang, Rui; Li, Qi; Shang, Da-Jing

    2018-03-01

    In order to determine the radiated sound power of an underwater source below the Schroeder cut-off frequency in a non-anechoic tank, a low-frequency extension measuring technique is proposed. This technique is based on a unique relationship between the transmission characteristics of the enclosed field and those of the free field, which can be obtained as a correction term based on previous measurements of a known simple source. The radiated sound power of an unknown underwater source in the free field can thereby be obtained accurately from measurements in a non-anechoic tank. To verify the validity of the proposed technique, a mathematical model of the enclosed field is established using normal-mode theory, and the relationship between the transmission characteristics of the enclosed and free fields is obtained. The radiated sound power of an underwater transducer source is tested in a glass tank using the proposed low-frequency extension measuring technique. Compared with the free field, the radiated sound power level of the narrowband spectrum deviation is found to be less than 3 dB, and the 1/3 octave spectrum deviation is found to be less than 1 dB. The proposed testing technique can be used not only to extend the low-frequency applications of non-anechoic tanks, but also for measurement of radiated sound power from complicated sources in non-anechoic tanks.

  12. A novel algorithm for osteoarthritis detection in Hough domain

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, Sabyasachi; Poria, Nilanjan; Chakraborty, Rajanya; Pratiher, Sawon; Mukherjee, Sukanya; Panigrahi, Prasanta K.

    2018-02-01

    Background subtraction of knee MRI images has been performed, followed by edge detection through canny edge detector. In order to avoid the discontinuities among edges, Daubechies-4 (Db-4) discrete wavelet transform (DWT) methodology is applied for the smoothening of edges identified through canny edge detector. The approximation coefficients of Db-4, having highest energy is selected to get rid of discontinuities in edges. Hough transform is then applied to find imperfect knee locations, as a function of distance (r) and angle (θ). The final outcome of the linear Hough transform is a two-dimensional array i.e., the accumulator space (r, θ) where one dimension of this matrix is the quantized angle θ and the other dimension is the quantized distance r. A novel algorithm has been suggested such that any deviation from the healthy knee bone structure for diseases like osteoarthritis can clearly be depicted on the accumulator space.

  13. Thunderstorms and ground-based radio noise as observed by radio astronomy Explorer 1

    NASA Technical Reports Server (NTRS)

    Caruso, J. A.; Herman, J. R.

    1973-01-01

    Radio Astronomy Explorer (RAE) data were analyzed to determine the frequency dependence of HF terrestrial radio noise power. RAE observations of individual thunderstorms, mid-ocean areas, and specific geographic regions for which concommitant ground based measurements are available indicate that noise power is a monotonically decreasing function of frequency which conforms to expectations over the geographic locations and time periods investigated. In all cases investigated, active thunderstorm regions emit slightly higher power as contrasted to RAE observations of the region during meteorologically quiet periods. Noise levels are some 15 db higher than predicted values over mid-ocean, while in locations where ground based measurements are available a maximum deviation of 5 db occurs. Worldwide contour mapping of the noise power at 6000 km for five individual months and four observing frequencies, examples of which are given, indicate high noise levels over continental land masses with corresponding lower levels over ocean regions.

  14. Visualizing the Sample Standard Deviation

    ERIC Educational Resources Information Center

    Sarkar, Jyotirmoy; Rashid, Mamunur

    2017-01-01

    The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…

  15. Diagnostic Ability of Automated Pupillography in Glaucoma.

    PubMed

    Rao, Harsha L; Kadambi, Sujatha V; Mehta, Pooja; Dasari, Srilakshmi; Puttaiah, Narendra K; Pradhan, Zia S; Rao, Dhanraj A S; Shetty, Rohit

    2017-05-01

    To evaluate the diagnostic ability of automated pupillography measurements in glaucoma and study the effect of inter-eye asymmetry in glaucomatous damage on the diagnostic ability. In an observational, cross-sectional study, 47 glaucoma patients and 42 control subjects underwent automated pupillography using a commercially available device. Diagnostic abilities of the pupillary response measurements were evaluated using area under receiver operating characteristic (ROC) curves (AUC) and sensitivities at fixed specificities. Influence of inter-eye asymmetry in glaucoma [inter-eye mean deviation (MD) difference on visual fields (VF)] on the diagnostic ability of pupillography parameters was evaluated by ROC regression approach. The AUCs of automated pupillography parameters ranged from 0.60 (amplitude score with peripheral blue stimulus) to 0.82 (amplitude score with full field white stimulus, Amp-FF-W). Sensitivity at 95% specificity ranged between 5% (amplitude score with full field blue stimulus) and 45% (amplitude score with full field green stimulus). Inter-eye MD difference significantly affected the diagnostic performance of automated pupillography parameters (p < 0.05). AUCs of Amp-FF-W at inter-eye MD difference of 0 dB, 5 dB, 10 dB and 15 dB were 0.71, 0.80, 0.87 and 0.93, respectively, according to the regression model. The corresponding sensitivities at 95% specificity were 20%, 34%, 50% and 66%, respectively. The diagnostic abilities of even the best automated pupillography parameters were only moderate in glaucoma. The performance of these pupillography measurements in detecting glaucoma significantly increased with greater inter-eye asymmetry in the glaucomatous damage.

  16. Design, Implementation and Applications of 3d Web-Services in DB4GEO

    NASA Astrophysics Data System (ADS)

    Breunig, M.; Kuper, P. V.; Dittrich, A.; Wild, P.; Butwilowski, E.; Al-Doori, M.

    2013-09-01

    The object-oriented database architecture DB4GeO was originally designed to support sub-surface applications in the geo-sciences. This is reflected in DB4GeO's geometric data model as well as in its import and export functions. Initially, these functions were designed for communication with 3D geological modeling and visualization tools such as GOCAD or MeshLab. However, it soon became clear that DB4GeO was suitable for a much wider range of applications. Therefore it is natural to move away from a standalone solution and to open the access to DB4GeO data by standardized OGC web-services. Though REST and OGC services seem incompatible at first sight, the implementation in DB4GeO shows that OGC-based implementation of web-services may use parts of the DB4GeO-REST implementation. Starting with initial solutions in the history of DB4GeO, this paper will introduce the design, adaptation (i.e. model transformation), and first steps in the implementation of OGC Web Feature (WFS) and Web Processing Services (WPS), as new interfaces to DB4GeO data and operations. Among its capabilities, DB4GeO can provide data in different data formats like GML, GOCAD, or DB3D XML through a WFS, as well as its ability to run operations like a 3D-to-2D service, or mesh-simplification (Progressive Meshes) through a WPS. We then demonstrate, an Android-based mobile 3D augmented reality viewer for DB4GeO that uses the Web Feature Service to visualize 3D geo-database query results. Finally, we explore future research work considering DB4GeO in the framework of the research group "Computer-Aided Collaborative Subway Track Planning in Multi-Scale 3D City and Building Models".

  17. Variation in the standard deviation of the lure rating distribution: Implications for estimates of recollection probability.

    PubMed

    Dopkins, Stephen; Varner, Kaitlin; Hoyer, Darin

    2017-10-01

    In word recognition semantic priming of test words increased the false-alarm rate and the mean of confidence ratings to lures. Such priming also increased the standard deviation of confidence ratings to lures and the slope of the z-ROC function, suggesting that the priming increased the standard deviation of the lure evidence distribution. The Unequal Variance Signal Detection (UVSD) model interpreted the priming as increasing the standard deviation of the lure evidence distribution. Without additional parameters the Dual Process Signal Detection (DPSD) model could only accommodate the results by fitting the data for related and unrelated primes separately, interpreting the priming, implausibly, as decreasing the probability of target recollection (DPSD). With an additional parameter, for the probability of false (lure) recollection the model could fit the data for related and unrelated primes together, interpreting the priming as increasing the probability of false recollection. These results suggest that DPSD estimates of target recollection probability will decrease with increases in the lure confidence/evidence standard deviation unless a parameter is included for false recollection. Unfortunately the size of a given lure confidence/evidence standard deviation relative to other possible lure confidence/evidence standard deviations is often unspecified by context. Hence the model often has no way of estimating false recollection probability and thereby correcting its estimates of target recollection probability.

  18. Down-Looking Interferometer Study II, Volume I,

    DTIC Science & Technology

    1980-03-01

    g(standard deviation of AN )(standard deviation of(3) where T’rm is the "reference spectrum", an estimate of the actual spectrum v gv T ’V Cgv . If jpj...spectrum T V . cgv . According to Eq. (2), Z is the standard deviation of the observed contrast spectral radiance AN divided by the effective rms system

  19. 40 CFR 61.207 - Radium-226 sampling and measurement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... B, Method 114. (3) Calculate the mean, x 1, and the standard deviation, s 1, of the n 1 radium-226... owner or operator of a phosphogypsum stack shall report the mean, standard deviation, 95th percentile..., Method 114. (4) Recalculate the mean and standard deviation of the entire set of n 2 radium-226...

  20. Antidiabetic screening of commercial botanical products in 3T3-L1 adipocytes and db/db mice.

    PubMed

    Babish, John G; Pacioretty, Linda M; Bland, Jeffrey S; Minich, Deanna M; Hu, Jeffrey; Tripp, Matthew L

    2010-06-01

    Numerous botanicals are purported to improve glucose metabolism and diabetic risk factors with varying degrees of supportive evidence. We investigated 203 commercially available botanical products representing 90 unique botanical species for effects on lipogenic activity in differentiating 3T3-L1 adipocytes. Anti-inflammatory activity of 21 of these products was further assessed in tumor necrosis factor alpha (TNFalpha)-stimulated, mature 3T3-L1 adipocytes. From these results, rho-isoalpha acids, Acacia nilotica bark, fennel, and wasabi were tested in the db/db mouse model. Fifty-nine percent of the 90 unique botanicals increased adipogenesis as did the standard troglitazone relative to the solvent controls. Botanical species with the greatest percentage of positive products were Centella asiatica, Panax quinquefolius, and Phyllanthus amarus at 100%, Vitis vinifera at 80%, Humulus lupulus at 71%, Aloe barbadensis at 66%, and Momordica charantia, Phaseolus vulgaris, and Punica granatum at 60%. All 21 subset samples inhibited TNFalpha-stimulated free fatty acid release and attenuated TNFalpha inhibition of adiponectin secretion. Both rho-isoalpha acids and A. nilotica reduced nonfasting glucose in the db/db mouse model, whereas A. nilotica also decreased nonfasting insulin levels. A post hoc analysis of the screening results indicated that the positive predictive value of the lipogenesis assay alone was 72%, while adding the criterion of a positive response in the anti-inflammatory assays increased this figure to 82%. Moreover, this large-scale evaluation demonstrates that antidiabetic, in vitro efficacy of botanicals is more a function of manufacturing or quality control differences than the presence of marker compounds and further underscores the need to develop functional as well as analytical bases for standardization of dietary supplements.

  1. [Long-term efficacy of laser peripheral iridotomy in preventing progression in eyes with pigment dispersion syndrome].

    PubMed

    Qing, Guoping; Zhang, Shaodan; Wang, Huaizhou; Wang, Tao; Wang, Shuhua; Chen, Hong; Wang, Hua; Wang, Ningli

    2014-07-01

    To evaluate the long-term efficacy of laser peripheral iridotomy (LPI) in preventing deterioration in eyes with pigment dispersion syndrome (PDS). A cohort study. Nineteen patients with PDS were treated with LPI and followed up periodically in Beijing Tongren Eye Center from May 2006 to April 2007. One eye of each patient was chosen randomly for the study. Main investigating items included iris configuration, intraocular pressure (IOP), anterior chamber pigmentation, and visual field analysis. The average follow-up period was (6.5 ± 0.3) years. A paired sample t test was used to determine whether there is a significant difference between average values of pre- and post-LPI IOP and mean deviation of Humphrey visual field analysis in these PDS eyes. The average age of the 19 patients were (35.8 ± 7.1) years on admission. The initial IOP of the 19 eyes was (24.7 ± 2.2) mmHg (1 mmHg = 0.133 kPa) before LPI. The mean deviation (MD) of Humphrey visual field analysis (VFA) were (-1.82 ± 1.26) dB (-4.34--0.28 dB) . All 19 eyes had concave iris and heavy trabecular pigmentation. The iris became flat in all PDS eyes after the laser treatment. At the last follow-up visit, the average IOP was 14.8 ± 2.0 (12-20) mmHg, which was statistically lower than that of baseline (t = 11.49, P < 0.01) . Extent of trabecular pigmentation reduced obviously in 16 eyes. No deterioration or new visual field defect was detected in any of the PDS eyes. MD of the last VFA was -1.79 ± 1.21 (-4.39--0.21 dB) . There was no statistical difference between MD of the last VFA and baseline (t = -0.26, P = 0.798). The long-term follow-up results showed that LPI prevents progression effectively in eyes with PDS.

  2. Flexner 2.0-Longitudinal Study of Student Participation in a Campus-Wide General Pathology Course for Graduate Students at The University of Arizona.

    PubMed

    Briehl, Margaret M; Nelson, Mark A; Krupinski, Elizabeth A; Erps, Kristine A; Holcomb, Michael J; Weinstein, John B; Weinstein, Ronald S

    2016-01-01

    Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, "Mechanisms of Human Disease." Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master's: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises.

  3. Flexner 2.0—Longitudinal Study of Student Participation in a Campus-Wide General Pathology Course for Graduate Students at The University of Arizona

    PubMed Central

    Briehl, Margaret M.; Nelson, Mark A.; Krupinski, Elizabeth A.; Erps, Kristine A.; Holcomb, Michael J.; Weinstein, John B.

    2016-01-01

    Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, “Mechanisms of Human Disease.” Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master’s: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises. PMID:28725783

  4. Hepatitis and the Need for Adequate Standards in Federally Supported Day Care.

    ERIC Educational Resources Information Center

    Silva, Richard J.

    1980-01-01

    This article examines findings in three epidemiological studies of day care centers and concludes that higher standards of care can reduce the incidence of hepatitis among parents and staff. (Author/DB)

  5. Complex apodized Bragg grating filters without circulators in silicon-on-insulator.

    PubMed

    Simard, Alexandre D; LaRochelle, Sophie

    2015-06-29

    Bragg gratings operating in reflection are versatile filters that are an important building block of photonic circuits but, so far, their use has been limited due to the absence of CMOS compatible integrated circulators. In this paper, we propose to introduce two identical Bragg gratings in the arms of a Mach-Zehnder interferometer built with multimode interference 2 x 2 couplers to provide a reflective filter without circulator. We show that this structure has unique properties that significantly reduce phase noise distortions, avoid the need for thermal phase tuning, and make it compatible with complex apodization functions implemented through superposition apodization. We experimentally demonstrate several Bragg grating filters with high quality reflection spectra. For example, we successfully fabricated a 4 nm dispersion-less square-shaped filter having a sidelobe suppression ratio better than 15 dB and an in-band phase response with a group delay standard deviation of 2.0 ps. This result will enable the fabrication of grating based narrowband reflective filters having sharp spectral responses, which represents a major improvement in the filtering capability of the silicon platform.

  6. The Effect of Microphone Type on Acoustical Measures of Synthesized Vowels.

    PubMed

    Kisenwether, Jessica Sofranko; Sataloff, Robert T

    2015-09-01

    The purpose of this study was to compare microphones of different directionality, transducer type, and cost, with attention to their effects on acoustical measurements of period perturbation, amplitude perturbation, and noise using synthesized sustained vowel samples. This was a repeated measures design. Synthesized sustained vowel stimuli (with known acoustic characteristics and systematic changes in jitter, shimmer, and noise-to-harmonics ratio) were recorded by a variety of dynamic and condenser microphones. Files were then analyzed for mean fundamental frequency (fo), fo standard deviation, absolute jitter, shimmer in dB, peak-to-peak amplitude variation, and noise-to-harmonics ratio. Acoustical measures following recording were compared with the synthesized, known acoustical measures before recording. Although informal analyses showed some differences among microphones, and analyses of variance showed that type of microphone is a significant predictor, t-tests revealed that none of the microphones generated different means compared with the generated acoustical measures. In this sample, microphone type, directionality, and cost did not have a significant effect on the validity of acoustic measures. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  7. 8 x 120 Gb/s unrepeatered transmission over 444 km (76.6 dB) using distributed Raman amplification and ROPA without discrete amplification.

    PubMed

    Chang, Do Il; Pelouch, Wayne; Patki, Pallavi; McLaughlin, John

    2011-12-12

    Unrepeatered transmission of 8 x 120 Gb/s over 444.2 km (76.6 dB) and multi-rate transmission of 8 x 120 Gb/s and 9 x 10.7 Gb/s over a 75.4 dB span have been demonstrated with off-line digital processing for the coherent 120 Gb/s channels. Transmission of 2 x 120 Gb/s with 7 x 12.5 Gb/s over 78 dB is also demonstrated with a real-time ASIC processor. All transmission results have been achieved using standard effective-area pure-silica-core fiber using forward and backward distributed Raman amplification and remotely-pumped erbium fiber. ASIC real-time processed results match well with off-line processing. © 2011 Optical Society of America

  8. Estimating occupant satisfaction of HVAC system noise using quality assessment index.

    PubMed

    Forouharmajd, Farhad; Nassiri, Parvin; Monazzam, Mohammad R; Yazdchi, Mohammadreza

    2012-01-01

    Noise may be defined as any unwanted sound. Sound becomes noise when it is too loud, unexpected, uncontrolled, happens at the wrong time, contains unwanted pure tones or unpleasant. In addition to being annoying, loud noise can cause hearing loss, and, depending on other factors, can affect stress level, sleep patterns and heart rate. The primary object for determining subjective estimations of loudness is to present sounds to a sample of listeners under controlled conditions. In heating, ventilation and air conditioning (HVAC) systems only the ventilation fan industry (e.g., bathroom exhaust and sidewall propeller fans) uses loudness ratings. In order to find satisfaction, percent of exposure to noise is the valuable issue for the personnel who are working in these areas. The room criterion (RC) method has been defined by ANSI standard S12.2, which is based on measured levels of in HVAC systems noise in spaces and is used primarily as a diagnostic tool. The RC method consists of a family of criteria curves and a rating procedure. RC measures background noise in the building over the frequency range of 16-4000 Hz. This rating system requires determination of the mid-frequency average level and determining the perceived balance between high-frequency (HF) sound and low-frequency (LF) sound. The arithmetic average of the sound levels in the 500, 1000 and 2000 Hz octave bands is 44.6 dB; therefore, the RC 45 curve is selected as the reference for spectrum quality evaluation. The spectral deviation factors in the LF, medium-frequency sound and HF regions are 2.9, 7.5 and -2.3, respectively, giving a Quality Assessment Index (QAI) of 9.8. This concludes the QAI is useful in estimating an occupant's probable reaction when the system design does not produce optimum sound quality. Thus, a QAI between 5 and 10 dB represents a marginal situation in which acceptance by an occupant is questionable. However, when sound pressure levels in the 16 or 31.5 Hz octave bands exceed 65 dB, vibration in lightweight office construction is possible.

  9. DB90: A Fortran Callable Relational Database Routine for Scientific and Engineering Computer Programs

    NASA Technical Reports Server (NTRS)

    Wrenn, Gregory A.

    2005-01-01

    This report describes a database routine called DB90 which is intended for use with scientific and engineering computer programs. The software is written in the Fortran 90/95 programming language standard with file input and output routines written in the C programming language. These routines should be completely portable to any computing platform and operating system that has Fortran 90/95 and C compilers. DB90 allows a program to supply relation names and up to 5 integer key values to uniquely identify each record of each relation. This permits the user to select records or retrieve data in any desired order.

  10. A Note on Standard Deviation and Standard Error

    ERIC Educational Resources Information Center

    Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth

    2010-01-01

    Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.

  11. Analytical quality goals derived from the total deviation from patients' homeostatic set points, with a margin for analytical errors.

    PubMed

    Bolann, B J; Asberg, A

    2004-01-01

    The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.

  12. Fully Integrated On-Chip Coil in 0.13 μm CMOS for Wireless Power Transfer Through Biological Media.

    PubMed

    Zargham, Meysam; Gulak, P Glenn

    2015-04-01

    Delivering milliwatts of wireless power at centimeter distances is advantageous to many existing and emerging biomedical applications. It is highly desirable to fully integrate the receiver on a single chip in standard CMOS with no additional post-processing steps or external components. This paper presents a 2 × 2.18 mm(2) on-chip wireless power transfer (WPT) receiver (Rx) coil fabricated in 0.13 μm CMOS. The WPT system utilizes a 14.5 × 14.5 mm(2) transmitter (Tx) coil that is fabricated on a standard FR4 substrate. The on-chip power harvester demonstrates a peak WPT efficiency of -18.47 dB , -20.96 dB and -20.15 dB at 10 mm of separation through air, bovine muscle and 0.2 molar NaCl, respectively. The achieved efficiency enables the delivery of milliwatts of power to application circuits while staying below safe power density and electromagnetic (EM) exposure limits.

  13. 14 CFR Appendix C to Part 91 - Operations in the North Atlantic (NAT) Minimum Navigation Performance Specifications (MNPS) Airspace

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... defined in section 1 of this appendix is as follows: (a) The standard deviation of lateral track errors shall be less than 6.3 NM (11.7 Km). Standard deviation is a statistical measure of data about a mean... standard deviation about the mean encompasses approximately 68 percent of the data and plus or minus 2...

  14. 47 CFR 80.767 - Propagation curve.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... data for field strengths in dBu for an effective radiated power of 1 kW, over sea water, fresh water or... referred to 1 kW (dBk), as follows: EC02AP91.005 where, Pt=Transmitter output power in dB referred to 1 kW... Graph 1 for a conversion graph. G=Antenna gain in dB referred to a standard half-wave dipole, in the...

  15. 47 CFR 80.767 - Propagation curve.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... data for field strengths in dBu for an effective radiated power of 1 kW, over sea water, fresh water or... referred to 1 kW (dBk), as follows: EC02AP91.005 where, Pt=Transmitter output power in dB referred to 1 kW... Graph 1 for a conversion graph. G=Antenna gain in dB referred to a standard half-wave dipole, in the...

  16. 47 CFR 80.767 - Propagation curve.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... data for field strengths in dBu for an effective radiated power of 1 kW, over sea water, fresh water or... referred to 1 kW (dBk), as follows: EC02AP91.005 where, Pt=Transmitter output power in dB referred to 1 kW... Graph 1 for a conversion graph. G=Antenna gain in dB referred to a standard half-wave dipole, in the...

  17. 47 CFR 80.767 - Propagation curve.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... data for field strengths in dBu for an effective radiated power of 1 kW, over sea water, fresh water or... referred to 1 kW (dBk), as follows: EC02AP91.005 where, Pt=Transmitter output power in dB referred to 1 kW... Graph 1 for a conversion graph. G=Antenna gain in dB referred to a standard half-wave dipole, in the...

  18. Repeatable source, site, and path effects on the standard deviation for empirical ground-motion prediction models

    USGS Publications Warehouse

    Lin, P.-S.; Chiou, B.; Abrahamson, N.; Walling, M.; Lee, C.-T.; Cheng, C.-T.

    2011-01-01

    In this study, we quantify the reduction in the standard deviation for empirical ground-motion prediction models by removing ergodic assumption.We partition the modeling error (residual) into five components, three of which represent the repeatable source-location-specific, site-specific, and path-specific deviations from the population mean. A variance estimation procedure of these error components is developed for use with a set of recordings from earthquakes not heavily clustered in space.With most source locations and propagation paths sampled only once, we opt to exploit the spatial correlation of residuals to estimate the variances associated with the path-specific and the source-location-specific deviations. The estimation procedure is applied to ground-motion amplitudes from 64 shallow earthquakes in Taiwan recorded at 285 sites with at least 10 recordings per site. The estimated variance components are used to quantify the reduction in aleatory variability that can be used in hazard analysis for a single site and for a single path. For peak ground acceleration and spectral accelerations at periods of 0.1, 0.3, 0.5, 1.0, and 3.0 s, we find that the singlesite standard deviations are 9%-14% smaller than the total standard deviation, whereas the single-path standard deviations are 39%-47% smaller.

  19. An Assessment of Current Fan Noise Prediction Capability

    NASA Technical Reports Server (NTRS)

    Envia, Edmane; Woodward, Richard P.; Elliott, David M.; Fite, E. Brian; Hughes, Christopher E.; Podboy, Gary G.; Sutliff, Daniel L.

    2008-01-01

    In this paper, the results of an extensive assessment exercise carried out to establish the current state of the art for predicting fan noise at NASA are presented. Representative codes in the empirical, analytical, and computational categories were exercised and assessed against a set of benchmark acoustic data obtained from wind tunnel tests of three model scale fans. The chosen codes were ANOPP, representing an empirical capability, RSI, representing an analytical capability, and LINFLUX, representing a computational aeroacoustics capability. The selected benchmark fans cover a wide range of fan pressure ratios and fan tip speeds, and are representative of modern turbofan engine designs. The assessment results indicate that the ANOPP code can predict fan noise spectrum to within 4 dB of the measurement uncertainty band on a third-octave basis for the low and moderate tip speed fans except at extreme aft emission angles. The RSI code can predict fan broadband noise spectrum to within 1.5 dB of experimental uncertainty band provided the rotor-only contribution is taken into account. The LINFLUX code can predict interaction tone power levels to within experimental uncertainties at low and moderate fan tip speeds, but could deviate by as much as 6.5 dB outside the experimental uncertainty band at the highest tip speeds in some case.

  20. Design and analysis of low-loss linear analog phase modulator for deep space spacecraft X-band transponder (DST) application

    NASA Technical Reports Server (NTRS)

    Mysoor, Narayan R.; Mueller, Robert O.

    1991-01-01

    This paper summarizes the design concepts, analyses, and the development of an X-band transponder low-loss linear phase modulator for deep space spacecraft applications. A single section breadboard circulator-coupled reflection phase modulator has been analyzed, fabricated, and evaluated. Two- and three-cascaded sections have been modeled and simulations performed to provide an X-band DST phase modulator with +/- 2.5 radians of peak phase deviation to accommodate down-link signal modulation with composite telemetry data and ranging with a deviation linearity tolerance +/- 8 percent and insertion loss of less than 10 +/- 0.5 dB. A two-section phase modulator using constant gamma hyperabrupt varactors and an efficient modulator driver circuit was breadboarded. The measured results satisfy the DST phase modulator requirements, and excellent agreement with the predicted results.

  1. Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry

    PubMed Central

    Grysiński, Tomasz; Kręcicki, Tomasz

    2018-01-01

    Background Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. Objective This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Methods Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. Results A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. Conclusions The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. PMID:29321124

  2. Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry.

    PubMed

    Masalski, Marcin; Grysiński, Tomasz; Kręcicki, Tomasz

    2018-01-10

    Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. ©Marcin Masalski, Tomasz Grysiński, Tomasz Kręcicki. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 10.01.2018.

  3. Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.

    PubMed

    Rao, Harsha L; Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-03-01

    To evaluate the effect of typical scan score (TSS), when within the acceptable limits, on the diagnostic performance of retinal nerve fibre layer (RNFL) parameters with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in glaucoma. In a cross-sectional study, 203 eyes of 160 glaucoma patients and 140 eyes of 104 control subjects underwent RNFL imaging with the ECC protocol of SLP. TSS was used to quantify atypical birefringence pattern (ABP) images. Influence of TSS on the diagnostic ability of SLP parameters was evaluated by receiver operating characteristic (ROC) regression models after adjusting for the effect of disease severity [based on mean deviation (MD)] on standard automated perimetry). Diagnostic abilities of all RNFL parameters of SLP increased when the TSS values were higher. This effect was statistically significant for TSNIT (coefficient: 0.08, p<0.001) and inferior average parameters (coefficient: 0.06, p=0.002) but not for nerve fibre indicator (NFI, coefficient: 0.03, p=0.21). In early glaucoma (MD of -5 dB), predicted area under ROC curve (AUC) for TSNIT average parameter improved from 0.642 at a TSS of 90 to 0.845 at a TSS of 100. In advanced glaucoma (MD of -15 dB), AUC for TSNIT average improved from 0.832 at a TSS of 90 to 0.947 at 100. Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits. Diagnostic ability of NFI was unaffected by TSS values. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Sensitivity and specificity of machine learning classifiers and spectral domain OCT for the diagnosis of glaucoma.

    PubMed

    Vidotti, Vanessa G; Costa, Vital P; Silva, Fabrício R; Resende, Graziela M; Cremasco, Fernanda; Dias, Marcelo; Gomi, Edson S

    2012-06-15

    Purpose. To investigate the sensitivity and specificity of machine learning classifiers (MLC) and spectral domain optical coherence tomography (SD-OCT) for the diagnosis of glaucoma. Methods. Sixty-two patients with early to moderate glaucomatous visual field damage and 48 healthy individuals were included. All subjects underwent a complete ophthalmologic examination, achromatic standard automated perimetry, and RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, California, USA). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters. Subsequently, the following MLCs were tested: Classification Tree (CTREE), Random Forest (RAN), Bagging (BAG), AdaBoost M1 (ADA), Ensemble Selection (ENS), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Naive-Bayes (NB), and Support Vector Machine (SVM). Areas under the ROC curves (aROCs) obtained for each parameter and each MLC were compared. Results. The mean age was 57.0±9.2 years for healthy individuals and 59.9±9.0 years for glaucoma patients (p=0.103). Mean deviation values were -4.1±2.4 dB for glaucoma patients and -1.5±1.6 dB for healthy individuals (p<0.001). The SD-OCT parameters with the greater aROCs were inferior quadrant (0.813), average thickness (0.807), 7 o'clock position (0.765), and 6 o'clock position (0.754). The aROCs from classifiers varied from 0.785 (ADA) to 0.818 (BAG). The aROC obtained with BAG was not significantly different from the aROC obtained with the best single SD-OCT parameter (p=0.93). Conclusions. The SD-OCT showed good diagnostic accuracy in a group of patients with early glaucoma. In this series, MLCs did not improve the sensitivity and specificity of SD-OCT for the diagnosis of glaucoma.

  5. Effect of central obscuration on the LDR point spread function

    NASA Technical Reports Server (NTRS)

    Vanzyl, Jakob J.

    1988-01-01

    It is well known that Gaussian apodization of an aperture reduces the sidelobe levels of its point spread function (PSF). In the limit where the standard deviation of the Gaussian function is much smaller than the diameter of the aperture, the sidelobes completely disappear. However, when Gaussian apodization is applied to the Large Deployable Reflector (LDR) array consisting of 84 hexagonal panels, it is found that the sidelobe level only decreases by about 2.5 dB. The reason for this is explained. The PSF is shown for an array consisting of 91 uniformly illuminated hexagonal apertures; this array is identical to the LDR array, except that the central hole in the LDR array is filled with seven additional panels. For comparison, the PSF of the uniformly illuminated LDR array is shown. Notice that it is already evident that the sidelobe structure of the LDR array is different from that of the full array of 91 panels. The PSF's of the same two arrays are shown, but with the illumination apodized with a Gaussian function to have 20 dB tapering at the edges of the arrays. While the sidelobes of the full array have decreased dramatically, those of the LDR array changed in structure, but stayed at almost the same level. This result is not completely surprising, since the Gaussian apodization tends to emphasize the contributions from the central portion of the array; exactly where the hole in the LDR array is located. The two most important conclusions are: the size of the central hole should be minimized, and a simple Gaussian apodization scheme to suppress the sidelobes in the PSF should not be used. A more suitable apodization scheme would be a Gaussian annular ring.

  6. Response of cardiac autonomic modulation after a single exposure to musical auditory stimulation

    PubMed Central

    Ferreira, Lucas L.; Vanderlei, Luiz Carlos M.; Guida, Heraldo L.; de Abreu, Luiz Carlos; Garner, David M.; Vanderlei, Franciele M.; Ferreira, Celso; Valenti, Vitor E.

    2015-01-01

    The acute effects after exposure to different styles of music on cardiac autonomic modulation assessed through heart rate variability (HRV) analysis have not yet been well elucidated. We aimed to investigate the recovery response of cardiac autonomic modulation in women after exposure to musical auditory stimulation of different styles. The study was conducted on 30 healthy women aged between 18 years and 30 years. We did not include subjects having previous experience with musical instruments and those who had an affinity for music styles. The volunteers remained at rest for 10 min and were exposed to classical baroque (64-84 dB) and heavy metal (75-84 dB) music for 10 min, and their HRV was evaluated for 30 min after music cessation. We analyzed the following HRV indices: Standard deviation of normal-to-normal (SDNN) intervals, root mean square of successive differences (RMSSD), percentage of normal-to-normal 50 (pNN50), low frequency (LF), high frequency (HF), and LF/HF ratio. SDNN, LF in absolute units (ms2) and normalized (nu), and LF/HF ratio increased while HF index (nu) decreased after exposure to classical baroque music. Regarding the heavy metal music style, it was observed that there were increases in SDNN, RMSSD, pNN50, and LF (ms2) after the musical stimulation. In conclusion, the recovery response of cardiac autonomic modulation after exposure to auditory stimulation with music featured an increased global activity of both systems for the two musical styles, with a cardiac sympathetic modulation for classical baroque music and a cardiac vagal tone for the heavy metal style. PMID:25774614

  7. A better norm-referenced grading using the standard deviation criterion.

    PubMed

    Chan, Wing-shing

    2014-01-01

    The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.

  8. Personal Background Preparation Survey for early identification of nursing students at risk for attrition.

    PubMed

    Johnson, Craig W; Johnson, Ronald; Kim, Mira; McKee, John C

    2009-11-01

    During 2004 and 2005 orientations, all 187 and 188 new matriculates, respectively, in two southwestern U.S. nursing schools completed Personal Background and Preparation Surveys (PBPS) in the first predictive validity study of a diagnostic and prescriptive instrument for averting adverse academic status events (AASE) among nursing or health science professional students. One standard deviation increases in PBPS risks (p < 0.05) multiplied odds of first-year or second-year AASE by approximately 150%, controlling for school affiliation and underrepresented minority student (URMS) status. AASE odds one standard deviation above mean were 216% to 250% those one standard deviation below mean. Odds of first-year or second-year AASE for URMS one standard deviation above the 2004 PBPS mean were 587% those for non-URMS one standard deviation below mean. The PBPS consistently and significantly facilitated early identification of nursing students at risk for AASE, enabling proactive targeting of interventions for risk amelioration and AASE or attrition prevention. Copyright 2009, SLACK Incorporated.

  9. Demonstration of the Gore Module for Passive Ground Water Sampling

    DTIC Science & Technology

    2014-06-01

    ix ACRONYMS AND ABBREVIATIONS % RSD percent relative standard deviation 12DCA 1,2-dichloroethane 112TCA 1,1,2-trichloroethane 1122TetCA...Analysis of Variance ROD Record of Decision RSD relative standard deviation SBR Southern Bush River SVOC semi-volatile organic compound...replicate samples had a relative standard deviation ( RSD ) that was 20% or less. For the remaining analytes (PCE, cDCE, and chloroform), at least 70

  10. Differential response of bone and kidney to ACEI in db/db mice: A potential effect of captopril on accelerating bone loss.

    PubMed

    Zhang, Yan; Li, Xiao-Li; Sha, Nan-Nan; Shu, Bing; Zhao, Yong-Jian; Wang, Xin-Luan; Xiao, Hui-Hui; Shi, Qi; Wong, Man-Sau; Wang, Yong-Jun

    2017-04-01

    The components of renin-angiotensin system (RAS) are expressed in the kidney and bone. Kidney disease and bone injury are common complications associated with diabetes. This study aimed to investigate the effects of an angiotensin-converting enzyme inhibitor, captopril, on the kidney and bone of db/db mice. The db/db mice were orally administered by gavage with captopril for 8weeks with db/+ mice as the non-diabetic control. Serum and urine biochemistries were determined by standard colorimetric methods or ELISA. Histological measurements were performed on the kidney by periodic acid-schiff staining and on the tibial proximal metaphysis by safranin O and masson-trichrome staining. Trabecular bone mass and bone quality were analyzed by microcomputed tomography. Quantitative polymerase chain reaction and immunoblotting were applied for molecular analysis on mRNA and protein expression. Captopril significantly improved albuminuria and glomerulosclerosis in db/db mice, and these effects might be attributed to the down-regulation of angiotensin II expression and the expression of its down-stream profibrotic factors in the kidney, like connective tissue growth factor and vascular endothelial growth factor. Urinary excretion of calcium and phosphorus markedly increased in db/db mice in response to captopril. Treatment with captopril induced a decrease in bone mineral density and deterioration of trabecular bone at proximal metaphysis of tibia in db/db mice, as shown in the histological and reconstructed 3-dimensional images. Even though captopril effectively reversed the diabetes-induced changes in calcium-binding protein 28-k and vitamin D receptor expression in the kidney as well as the expression of RAS components and bradykinin receptor-2 in bone tissue, treatment with captopril increased the osteoclast-covered bone surface, reduced the osteoblast-covered bone surface, down-regulated the expression of type 1 collagen and transcription factor runt-related transcription factor 2 (markers for osteoblastic functions), and up-regulated the expression of carbonic anhydrase II (marker for bone resorption). Captopril exerted therapeutic effects on renal injuries associated with type 2 diabetes but worsened the deteriorations of trabecular bone in db/db mice; the latter of which was at least in part due to the stimulation of osteoclastogenesis and the suppression of osteogenesis by captopril. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Impact of baseline systolic blood pressure on visit-to-visit blood pressure variability: the Kailuan study.

    PubMed

    Wang, Anxin; Li, Zhifang; Yang, Yuling; Chen, Guojuan; Wang, Chunxue; Wu, Yuntao; Ruan, Chunyu; Liu, Yan; Wang, Yilong; Wu, Shouling

    2016-01-01

    To investigate the relationship between baseline systolic blood pressure (SBP) and visit-to-visit blood pressure variability in a general population. This is a prospective longitudinal cohort study on cardiovascular risk factors and cardiovascular or cerebrovascular events. Study participants attended a face-to-face interview every 2 years. Blood pressure variability was defined using the standard deviation and coefficient of variation of all SBP values at baseline and follow-up visits. The coefficient of variation is the ratio of the standard deviation to the mean SBP. We used multivariate linear regression models to test the relationships between SBP and standard deviation, and between SBP and coefficient of variation. Approximately 43,360 participants (mean age: 48.2±11.5 years) were selected. In multivariate analysis, after adjustment for potential confounders, baseline SBPs <120 mmHg were inversely related to standard deviation (P<0.001) and coefficient of variation (P<0.001). In contrast, baseline SBPs ≥140 mmHg were significantly positively associated with standard deviation (P<0.001) and coefficient of variation (P<0.001). Baseline SBPs of 120-140 mmHg were associated with the lowest standard deviation and coefficient of variation. The associations between baseline SBP and standard deviation, and between SBP and coefficient of variation during follow-ups showed a U curve. Both lower and higher baseline SBPs were associated with increased blood pressure variability. To control blood pressure variability, a good target SBP range for a general population might be 120-139 mmHg.

  12. Simulation and analysis of spectroscopic filter of rotational Raman lidar for absolute measurement of atmospheric temperature

    NASA Astrophysics Data System (ADS)

    Li, Qimeng; Li, Shichun; Hu, Xianglong; Zhao, Jing; Xin, Wenhui; Song, Yuehui; Hua, Dengxin

    2018-01-01

    The absolute measurement technique for atmospheric temperature can avoid the calibration process and improve the measurement accuracy. To achieve the rotational Raman temperature lidar of absolute measurement, the two-stage parallel multi-channel spectroscopic filter combined a first-order blazed grating with a fiber Bragg grating is designed and its performance is tested. The parameters and the optical path structure of the core cascaded-device (micron-level fiber array) are optimized, the optical path of the primary spectroscope is simulated and the maximum centrifugal distortion of the rotational Raman spectrum is approximately 0.0031 nm, the centrifugal ratio of 0.69%. The experimental results show that the channel coefficients of the primary spectroscope are 0.67, 0.91, 0.67, 0.75, 0.82, 0.63, 0.87, 0.97, 0.89, 0.87 and 1 by using the twelfth channel as a reference and the average FWHM is about 0.44 nm. The maximum deviation between the experimental wavelength and the theoretical value is approximately 0.0398 nm, with the deviation degree of 8.86%. The effective suppression to elastic scattering signal are 30.6, 35.2, 37.1, 38.4, 36.8, 38.2, 41.0, 44.3, 44.0, 46.7 dB. That means, combined with the second spectroscope, the suppression at least is up to 65 dB. Therefore we can fine extract single rotational Raman line to achieve the absolute measurement technique.

  13. Response of personal noise dosimeters to continuous and impulse-like signals

    NASA Astrophysics Data System (ADS)

    Evans, D. J.; Flynn, D. R.; Nedzelnitsky, V.; Burnett, E. D.

    1991-06-01

    A study of the capabilities of noise dosimeters to measure personal exposure to time varying and impulse-like noises was carried out. Ten commercial noise dosimeters were obtained. A laboratory reference noise dosimeter was constructed to provide a demonstrably accurate basis with which to compare the commercial noise dosimeters. Each commercial dosimeter, when ordered from the manufacturer, was specified to have a threshold A-weighted sound level of 80 dB, a criterion sound level of 90 dB, and an exchange rate of 5 dB and/or 3 dB. The performance of the commercial dosimeters was compared with theory and with results obtained from the reference dosimeter. Except in a few isolated cases, the commercial dosimeters were in general agreement with the performance specification of the appropriate American National Standard and with the Occupational Safety and Health Administration (OSHA) regulations.

  14. Flexner 3.0-Democratization of Medical Knowledge for the 21st Century: Teaching Medical Science Using K-12 General Pathology as a Gateway Course.

    PubMed

    Weinstein, Ronald S; Krupinski, Elizabeth A; Weinstein, John B; Graham, Anna R; Barker, Gail P; Erps, Kristine A; Holtrust, Angelette L; Holcomb, Michael J

    2016-01-01

    A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school ( F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender ( F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level ( F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student's expectations. One class voted K-12 general pathology their "elective course-of-the-year."

  15. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range.

    PubMed

    Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun

    2014-12-19

    In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different situations.

  16. Flexner 3.0—Democratization of Medical Knowledge for the 21st Century

    PubMed Central

    Krupinski, Elizabeth A.; Weinstein, John B.; Graham, Anna R.; Barker, Gail P.; Erps, Kristine A.; Holtrust, Angelette L.; Holcomb, Michael J.

    2016-01-01

    A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school (F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender (F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level (F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student’s expectations. One class voted K-12 general pathology their “elective course-of-the-year.” PMID:28725762

  17. [Evaluation of strategies aimed at reducing the level of noise in different areas of neonatal care in a tertiary hospital].

    PubMed

    Nieto-Sanjuanero, Adriana; Quero-Jiménez, José; Cantú-Moreno, Daniel; Rodríguez-Balderrama, Isaías; Montes-Tapia, Fernando; Rubio-Pérez, Nadina; Treviño-Garza, Consuelo; de la O-Cavazos, Manuel

    2015-01-01

    To determine the noise levels of different areas responsible for newborn care, develop intervention strategies to decrease the noise, and evaluate its effectiveness. Prospective, observational and longitudinal study carried out using a sonometer, measuring sound levels for three weeks in the neonatal intensive care unit (NICU), neonatal intermediate care unit (UCIREN), delivery (TOCO QX) and nursery (CUNERO) units. We implemented an intervention program and subsequent measurements were performed under the same initial conditions. When comparing the decibel levels in different areas during the three weeks, pre- and post-intervention, we found at the neonatal intensive care unit 59.9±4.8 vs. 56.4±4.7 dB (p<0.001), neonatal intermediate care unit 55.3±3.9 vs. 51.3±4.4 dB (p<0.001), delivery unit 57.3±4.6 vs. 57.3±5.5 dB (NS), and nursery unit 57.6±5.8 vs. 53.9±5.8 dB (p<0.001). There was a significant reduction in noise levels of 3.5 dB at the NICU, 4 dB at UCIREN and 3.7 dB at TOCO QX, so the intervention program was effective in these areas; however, the decibel levels registered continue above those recommended by international standards.

  18. GeneSigDB: a manually curated database and resource for analysis of gene expression signatures

    PubMed Central

    Culhane, Aedín C.; Schröder, Markus S.; Sultana, Razvan; Picard, Shaita C.; Martinelli, Enzo N.; Kelly, Caroline; Haibe-Kains, Benjamin; Kapushesky, Misha; St Pierre, Anne-Alyssa; Flahive, William; Picard, Kermshlise C.; Gusenleitner, Daniel; Papenhausen, Gerald; O'Connor, Niall; Correll, Mick; Quackenbush, John

    2012-01-01

    GeneSigDB (http://www.genesigdb.org or http://compbio.dfci.harvard.edu/genesigdb/) is a database of gene signatures that have been extracted and manually curated from the published literature. It provides a standardized resource of published prognostic, diagnostic and other gene signatures of cancer and related disease to the community so they can compare the predictive power of gene signatures or use these in gene set enrichment analysis. Since GeneSigDB release 1.0, we have expanded from 575 to 3515 gene signatures, which were collected and transcribed from 1604 published articles largely focused on gene expression in cancer, stem cells, immune cells, development and lung disease. We have made substantial upgrades to the GeneSigDB website to improve accessibility and usability, including adding a tag cloud browse function, facetted navigation and a ‘basket’ feature to store genes or gene signatures of interest. Users can analyze GeneSigDB gene signatures, or upload their own gene list, to identify gene signatures with significant gene overlap and results can be viewed on a dynamic editable heatmap that can be downloaded as a publication quality image. All data in GeneSigDB can be downloaded in numerous formats including .gmt file format for gene set enrichment analysis or as a R/Bioconductor data file. GeneSigDB is available from http://www.genesigdb.org. PMID:22110038

  19. Estimation of the neural drive to the muscle from surface electromyograms

    NASA Astrophysics Data System (ADS)

    Hofmann, David

    Muscle force is highly correlated with the standard deviation of the surface electromyogram (sEMG) produced by the active muscle. Correctly estimating this quantity of non-stationary sEMG and understanding its relation to neural drive and muscle force is of paramount importance. The single constituents of the sEMG are called motor unit action potentials whose biphasic amplitude can interfere (named amplitude cancellation), potentially affecting the standard deviation (Keenan etal. 2005). However, when certain conditions are met the Campbell-Hardy theorem suggests that amplitude cancellation does not affect the standard deviation. By simulation of the sEMG, we verify the applicability of this theorem to myoelectric signals and investigate deviations from its conditions to obtain a more realistic setting. We find no difference in estimated standard deviation with and without interference, standing in stark contrast to previous results (Keenan etal. 2008, Farina etal. 2010). Furthermore, since the theorem provides us with the functional relationship between standard deviation and neural drive we conclude that complex methods based on high density electrode arrays and blind source separation might not bear substantial advantages for neural drive estimation (Farina and Holobar 2016). Funded by NIH Grant Number 1 R01 EB022872 and NSF Grant Number 1208126.

  20. QSAR DataBank - an approach for the digital organization and archiving of QSAR model information

    PubMed Central

    2014-01-01

    Background Research efforts in the field of descriptive and predictive Quantitative Structure-Activity Relationships or Quantitative Structure–Property Relationships produce around one thousand scientific publications annually. All the materials and results are mainly communicated using printed media. The printed media in its present form have obvious limitations when they come to effectively representing mathematical models, including complex and non-linear, and large bodies of associated numerical chemical data. It is not supportive of secondary information extraction or reuse efforts while in silico studies poses additional requirements for accessibility, transparency and reproducibility of the research. This gap can and should be bridged by introducing domain-specific digital data exchange standards and tools. The current publication presents a formal specification of the quantitative structure-activity relationship data organization and archival format called the QSAR DataBank (QsarDB for shorter, or QDB for shortest). Results The article describes QsarDB data schema, which formalizes QSAR concepts (objects and relationships between them) and QsarDB data format, which formalizes their presentation for computer systems. The utility and benefits of QsarDB have been thoroughly tested by solving everyday QSAR and predictive modeling problems, with examples in the field of predictive toxicology, and can be applied for a wide variety of other endpoints. The work is accompanied with open source reference implementation and tools. Conclusions The proposed open data, open source, and open standards design is open to public and proprietary extensions on many levels. Selected use cases exemplify the benefits of the proposed QsarDB data format. General ideas for future development are discussed. PMID:24910716

  1. Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.

    PubMed

    Bowman, Richard G; Caraway, David; Bentley, Ishmael

    2013-01-01

    Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.

  2. Binaural speech discrimination under noise in hearing-impaired listeners.

    PubMed

    Kumar, K V; Rao, A B

    1988-10-01

    This study was undertaken to assess speech discrimination under binaural listening with background noise in hearing-impaired subjects. Subjects (58 sensori-neural, 23 conductive, and 19 mixed) were administered an indigenous version of W-22 PB words under: Condition I--Quiet--chamber noise below 28 dB with speech at 60 dB; and at a constant signal-to-noise (S/N) ratio of +10 dB with background white noise at 70 dB in Condition II and 80 dB in Condition III. The scores were a) 81 +/- 16%, b) 77 +/- 9%, and c) 79 +/- 13%. Mean scores decreased significantly (p less than 0.001) with noise in all groups while the score was more (p less than 0.001) at the higher noise level only in the sensori-neural group. The decrease in scores with advancing hearing impairment was less in noise than in quiet, probably due to binaural and satisfactory S/N ratio. The scores did not fall below 70% unless the handicap was marked. The need for suitable standards of binaural speech discrimination under noise in aircrew assessment is emphasized.

  3. Computer Programs for the Semantic Differential: Further Modifications.

    ERIC Educational Resources Information Center

    Lawson, Edwin D.; And Others

    The original nine programs for semantic differential analysis have been condensed into three programs which have been further refined and augmented. They yield: (1) means, standard deviations, and standard errors for each subscale on each concept; (2) Evaluation, Potency, and Activity (EPA) means, standard deviations, and standard errors; (3)…

  4. Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.

    PubMed

    McClure, Foster D; Lee, Jung K

    2006-01-01

    A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.

  5. Long distance measurement-device-independent quantum key distribution with entangled photon sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Feihu; Qi, Bing; Liao, Zhongfa

    2013-08-05

    We present a feasible method that can make quantum key distribution (QKD), both ultra-long-distance and immune, to all attacks in the detection system. This method is called measurement-device-independent QKD (MDI-QKD) with entangled photon sources in the middle. By proposing a model and simulating a QKD experiment, we find that MDI-QKD with one entangled photon source can tolerate 77 dB loss (367 km standard fiber) in the asymptotic limit and 60 dB loss (286 km standard fiber) in the finite-key case with state-of-the-art detectors. Our general model can also be applied to other non-QKD experiments involving entanglement and Bell state measurements.

  6. [Vocal capabilities of nonprofessional singers evaluated by measurement and superimposition of their speaking, shouting and singing voice range profiles].

    PubMed

    Hacki, T

    1999-09-01

    Voice range profile(VRP) measurement (Phonetography) was used for the evaluation of the vocal capabilities of 41 female (F) and 50 male (M) members of a nonprofessional choir. By means of an automatic VPR measurement system F0 and SPL dB(A) were determined and displayed real time, two-dimensionally. The speaking voice (reading a standard passage as well as counting from the softest to the loudest intensity), the shouting voice (3-4 times shouting a standard sentence) and the singing voice (sustained phonation / la:/ at minimum and maximum intensity level) were measured. The VRPs of these voice modalities were superimposed on the screen and the plot. The averaged values for the speaking VRP: intensity range (F): 48 dB (range 46 soft to 94 dB loud phonation), (M): 52 dB (range 46-98). Pitch range (F): 15 semitones (ST) (Cis3, 138-E4, 329 Hz), (M): 19 ST (E2, 82 Hz-H3, 246 Hz). The average slope for the speaking voice (F): 0,31 ST/dB, (M): 0,36 ST/dB. Shouting VRP highest intensity (F): 106,5 dB, (M): 108,5 dB, highest pitch (F): between Ais4, 466 and H4, 493 Hz. (M): E4, 329 Hz. Average slope for speaking and shouting voice (F): 0,36 ST/dB, (M): 0,39 ST/dB. Singing VRP pitch range (F): 34,6 ST, (M): 37 ST, intensity range (F): 60 dB, (M): 58 dB. The pitch extension of the speaking VRP ranges from 2,9 to 46,2%, speaking and shouting VRPs together with 2,9 to 65% of the pitch range of the singing VRP (F), (M) 2,7-54% and 2,7-67,5% accordingly. The average values for nonprofessional singers reflect an effective but not special use of the phonatory system for the speaking, shouting and singing voice functions with respect to pitch and intensity.

  7. Packing Fraction of a Two-dimensional Eden Model with Random-Sized Particles

    NASA Astrophysics Data System (ADS)

    Kobayashi, Naoki; Yamazaki, Hiroshi

    2018-01-01

    We have performed a numerical simulation of a two-dimensional Eden model with random-size particles. In the present model, the particle radii are generated from a Gaussian distribution with mean μ and standard deviation σ. First, we have examined the bulk packing fraction for the Eden cluster and investigated the effects of the standard deviation and the total number of particles NT. We show that the bulk packing fraction depends on the number of particles and the standard deviation. In particular, for the dependence on the standard deviation, we have determined the asymptotic value of the bulk packing fraction in the limit of the dimensionless standard deviation. This value is larger than the packing fraction obtained in a previous study of the Eden model with uniform-size particles. Secondly, we have investigated the packing fraction of the entire Eden cluster including the effect of the interface fluctuation. We find that the entire packing fraction depends on the number of particles while it is independent of the standard deviation, in contrast to the bulk packing fraction. In a similar way to the bulk packing fraction, we have obtained the asymptotic value of the entire packing fraction in the limit NT → ∞. The obtained value of the entire packing fraction is smaller than that of the bulk value. This fact suggests that the interface fluctuation of the Eden cluster influences the packing fraction.

  8. Complexities of follicle deviation during selection of a dominant follicle in Bos taurus heifers.

    PubMed

    Ginther, O J; Baldrighi, J M; Siddiqui, M A R; Araujo, E R

    2016-11-01

    Follicle deviation during a follicular wave is a continuation in growth rate of the dominant follicle (F1) and decreased growth rate of the largest subordinate follicle (F2). The reliability of using an F1 of 8.5 mm to represent the beginning of expected deviation for experimental purposes during waves 1 and 2 (n = 26 per wave) was studied daily in heifers. Each wave was subgrouped as follows: standard subgroup (F1 larger than F2 for 2 days preceding deviation and F2 > 7.0 mm on the day of deviation), undersized subgroup (F2 did not attain 7.0 mm by the day of deviation), and switched subgroup (F2 larger than F1 at least once on the 2 days before or on the day of deviation). For each wave, mean differences in diameter between F1 and F2 changed abruptly at expected deviation in the standard subgroup but began 1 day before expected deviation in the undersized and switched subgroups. Concentrations of FSH in the wave-stimulating FSH surge and an increase in LH centered on expected deviation did not differ among subgroups. Results for each wave indicated that (1) expected deviation (F1, 8.5 mm) was a reliable representation of actual deviation in the standard subgroup but not in the undersized and switched subgroups; (2) concentrations of the gonadotropins normalized to expected deviation were similar among the three subgroups, indicating that the day of deviation was related to diameter of F1 and not F2; and (3) defining an expected day of deviation for experimental use should consider both diameter of F1 and the characteristics of deviation. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Test-retest reliability of probe-microphone verification in children fitted with open and closed hearing aid tips.

    PubMed

    Kim, Hannah; Ricketts, Todd A

    2013-01-01

    To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). Probe-microphone measurements were completed for two mini-behind-the-ear (BTE) hearing aids which were coupled to the ear using open and closed eartips via thin (0.9 mm) tubing. Before probe-microphone testing, the gain of each of the test hearing aids was programmed using an artificial ear simulator (IEC 711) and a Knowles Electronic Manikin for Acoustic Research to match the National Acoustic Laboratories-Non-Linear, version 1 targets for one of two separate hearing loss configurations using an Audioscan Verifit. No further adjustments were made, and the same amplifier gain was used within each hearing aid across both eartip configurations and all participants. Probe-microphone testing included real-ear occluded response (REOR) and REAR measures using the Verifit's standard speech signal (the carrot passage) presented at 65 dB sound pressure level (SPL). Two repeated probe-microphone measures were made for each participant with the probe-tube and hearing aid removed and repositioned between each trial in order to assess intrasubject measurement variability. These procedures were repeated using both open and closed domes. Thirty-two children, ages ranging from 4 to 14 yr. The test-retest standard deviations for open and closed measures did not exceed 4 dB at any frequency. There was also no significant difference between the open (stored equalization) and closed (concurrent equalization) methods. Reliability was particularly similar in the high frequencies and was also quite similar to that reported in previous research. There was no correlation between reliability and age, suggesting high reliability across all ages evaluated. The findings from this study suggest that reliable probe-microphone measurements are obtainable on children 4 yr and older for both traditional unvented and open-canal hearing aid fittings. These data suggest that clinicians should not avoid fitting open technology to children as young as 4 y because of concerns regarding the reliability of verification techniques. American Academy of Audiology.

  10. 40 CFR 90.708 - Cumulative Sum (CumSum) procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... is 5.0×σ, and is a function of the standard deviation, σ. σ=is the sample standard deviation and is... individual engine. FEL=Family Emission Limit (the standard if no FEL). F=.25×σ. (2) After each test pursuant...

  11. Acoustic Correlates of Compensatory Adjustments to the Glottic and Supraglottic Structures in Patients with Unilateral Vocal Fold Paralysis

    PubMed Central

    2015-01-01

    The goal of this study was to analyse perceptually and acoustically the voices of patients with Unilateral Vocal Fold Paralysis (UVFP) and compare them to the voices of normal subjects. These voices were analysed perceptually with the GRBAS scale and acoustically using the following parameters: mean fundamental frequency (F0), standard-deviation of F0, jitter (ppq5), shimmer (apq11), mean harmonics-to-noise ratio (HNR), mean first (F1) and second (F2) formants frequency, and standard-deviation of F1 and F2 frequencies. Statistically significant differences were found in all of the perceptual parameters. Also the jitter, shimmer, HNR, standard-deviation of F0, and standard-deviation of the frequency of F2 were statistically different between groups, for both genders. In the male data differences were also found in F1 and F2 frequencies values and in the standard-deviation of the frequency of F1. This study allowed the documentation of the alterations resulting from UVFP and addressed the exploration of parameters with limited information for this pathology. PMID:26557690

  12. Dynamics of the standard deviations of three wind velocity components from the data of acoustic sounding

    NASA Astrophysics Data System (ADS)

    Krasnenko, N. P.; Kapegesheva, O. F.; Shamanaeva, L. G.

    2017-11-01

    Spatiotemporal dynamics of the standard deviations of three wind velocity components measured with a mini-sodar in the atmospheric boundary layer is analyzed. During the day on September 16 and at night on September 12 values of the standard deviation changed for the x- and y-components from 0.5 to 4 m/s, and for the z-component from 0.2 to 1.2 m/s. An analysis of the vertical profiles of the standard deviations of three wind velocity components for a 6-day measurement period has shown that the increase of σx and σy with altitude is well described by a power law dependence with exponent changing from 0.22 to 1.3 depending on the time of day, and σz depends linearly on the altitude. The approximation constants have been found and their errors have been estimated. The established physical regularities and the approximation constants allow the spatiotemporal dynamics of the standard deviation of three wind velocity components in the atmospheric boundary layer to be described and can be recommended for application in ABL models.

  13. A proof for Rhiel's range estimator of the coefficient of variation for skewed distributions.

    PubMed

    Rhiel, G Steven

    2007-02-01

    In this research study is proof that the coefficient of variation (CV(high-low)) calculated from the highest and lowest values in a set of data is applicable to specific skewed distributions with varying means and standard deviations. Earlier Rhiel provided values for d(n), the standardized mean range, and a(n), an adjustment for bias in the range estimator of micro. These values are used in estimating the coefficient of variation from the range for skewed distributions. The d(n) and an values were specified for specific skewed distributions with a fixed mean and standard deviation. In this proof it is shown that the d(n) and an values are applicable for the specific skewed distributions when the mean and standard deviation can take on differing values. This will give the researcher confidence in using this statistic for skewed distributions regardless of the mean and standard deviation.

  14. Standard Practice for the Selection and Application of Marine Deck Coverings

    DTIC Science & Technology

    1992-07-01

    floors to reduce the transmission of noise and vibrations. These typically consist of layers of mineral wool or mineral wool panel sections with a...crew efficiency. Floating deck systems are generally composed of an insulating material such as mineral wool that are laid loose on the structural...Chapter II-2, Part A, Regulation 3(c). Sound Reduction Index - 44 dB Sound Insulation Index (Ia) - 47 dB Density of Mineral Wool - 10 pounds per

  15. Random errors in interferometry with the least-squares method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Qi

    2011-01-20

    This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less

  16. [Acoustic conditions in open plan offices - Pilot test results].

    PubMed

    Mikulski, Witold

    The main source of noise in open plan office are conversations. Office work standards in such premises are attained by applying specific acoustic adaptation. This article presents the results of pilot tests and acoustic evaluation of open space rooms. Acoustic properties of 6 open plan office rooms were the subject of the tests. Evaluation parameters, measurement methods and criterial values were adopted according to the following standards: PN-EN ISO 3382- 3:2012, PN-EN ISO 3382-2:2010, PN-B-02151-4:2015-06 and PN-B-02151-3:2015-10. The reverberation time was 0.33- 0.55 s (maximum permissible value in offices - 0.6 s; the criterion was met), sound absorption coefficient in relation to 1 m2 of the room's plan was 0.77-1.58 m2 (minimum permissible value - 1.1 m2; 2 out of 6 rooms met the criterion), distraction distance was 8.5-14 m (maximum permissible value - 5 m; none of the rooms met the criterion), A-weighted sound pressure level of speech at a distance of 4 m was 43.8-54.7 dB (maximum permissible value - 48 dB; 2 out of 6 rooms met the criterion), spatial decay rate of the speech was 1.8-6.3 dB (minimum permissible value - 7 dB; none of the rooms met the criterion). Standard acoustic treatment, containing sound absorbing suspended ceiling, sound absorbing materials on the walls, carpet flooring and sound absorbing workplace barriers, is not sufficient. These rooms require specific advanced acoustic solutions. Med Pr 2016;67(5):653-662. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. N2/O2/H2 Dual-Pump Cars: Validation Experiments

    NASA Technical Reports Server (NTRS)

    OByrne, S.; Danehy, P. M.; Cutler, A. D.

    2003-01-01

    The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.

  18. Comparing NAL-NL1 and DSL v5 in Hearing Aids Fit to Children with Severe or Profound Hearing Loss: Goodness of Fit-to-Targets, Impacts on Predicted Loudness and Speech Intelligibility.

    PubMed

    Ching, Teresa Y C; Quar, Tian Kar; Johnson, Earl E; Newall, Philip; Sharma, Mridula

    2015-03-01

    An important goal of providing amplification to children with hearing loss is to ensure that hearing aids are adjusted to match targets of prescriptive procedures as closely as possible. The Desired Sensation Level (DSL) v5 and the National Acoustic Laboratories' prescription for nonlinear hearing aids, version 1 (NAL-NL1) procedures are widely used in fitting hearing aids to children. Little is known about hearing aid fitting outcomes for children with severe or profound hearing loss. The purpose of this study was to investigate the prescribed and measured gain of hearing aids fit according to the NAL-NL1 and the DSL v5 procedure for children with moderately severe to profound hearing loss; and to examine the impact of choice of prescription on predicted speech intelligibility and loudness. Participants were fit with Phonak Naida V SP hearing aids according to the NAL-NL1 and DSL v5 procedures. The Speech Intelligibility Index (SII) and estimated loudness were calculated using published models. The sample consisted of 16 children (30 ears) aged between 7 and 17 yr old. The measured hearing aid gains were compared with the prescribed gains at 50 (low), 65 (medium), and 80 dB SPL (high) input levels. The goodness of fit-to-targets was quantified by calculating the average root-mean-square (RMS) error of the measured gain compared with prescriptive gain targets for 0.5, 1, 2, and 4 kHz. The significance of difference between prescriptions for hearing aid gains, SII, and loudness was examined by performing analyses of variance. Correlation analyses were used to examine the relationship between measures. The DSL v5 prescribed significantly higher overall gain than the NAL-NL1 procedure for the same audiograms. For low and medium input levels, the hearing aids of all children fit with NAL-NL1 were within 5 dB RMS of prescribed targets, but 33% (10 ears) deviated from the DSL v5 targets by more than 5 dB RMS on average. For high input level, the hearing aid fittings of 60% and 43% of ears deviated by more than 5 dB RMS from targets of NAL-NL1 and DSL v5, respectively. Greater deviations from targets were associated with more severe hearing loss. On average, the SII was higher for DSL v5 than for NAL-NL1 at low input level. No significant difference in SII was found between prescriptions at medium or high input level, despite greater loudness for DSL v5 than for NAL-NL1. Although targets between 0.25 and 2 kHz were well matched for both prescriptions in commercial hearing aids, gain targets at 4 kHz were matched for NAL-NL1 only. Although the two prescriptions differ markedly in estimated loudness, they resulted in comparable predicted speech intelligibility for medium and high input levels. American Academy of Audiology.

  19. [Assessment comparison between area sampling and personal sampling noise measurement in new thermal power plant].

    PubMed

    Zhang, Hua; Chen, Qing-song; Li, Nan; Hua, Yan; Zeng, Lin; Xu, Guo-yang; Tao, Li-yuan; Zhao, Yi-ming

    2013-05-01

    To compare the results of noise hazard evaluations based on area sampling and personal sampling in a new thermal power plant and to analyze the similarities and differences between the two measurement methods. According to Measurement of Physical agents in Workplace Part 8: Noise(GBZff 189.8-2007), area sampling was performed at various operating points for noise measurement, and meanwhile the workers under different types of work wore noise dosimeters for personal noise exposure measurement. The two measurement methods were used to evaluate the level of noise hazards in the enterprise according to the corresponding occupational health standards, and the evaluation results were compared. Area sampling was performed at 99 operating points, the mean noise level was 88.9 ± 11.1 dB (A)(range, 51.3-107.0 dB (A)), with an over-standard rate of 75.8%. Personal sampling was performed (73 person times),and the mean noise level was 79.3 ± 6.3 dB (A), with an over-standard rate of 6.6% ( 16/241 ). There was a statistically significant difference in the over-standard rate between the evaluation results of the two measurement methods ( x2=53.869, ?<0.001 ). Because of the characteristics of the work in new thermal power plants, the noise hazard evaluation based on area sampling cannot be used instead of personal noise exposure measurement among workers. Personal sampling should be used in the noise measurement in new thermal power plant.

  20. Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.

    PubMed

    Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O

    2009-04-01

    Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P < .0001). The recipient plug removal angle using the navigated technique was 3.3 degrees (standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P < .0001). The mean navigated recipient plug placement angle was 3.6 degrees (standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.

  1. 2 GHz clock quantum key distribution over 260 km of standard telecom fiber.

    PubMed

    Wang, Shuang; Chen, Wei; Guo, Jun-Fu; Yin, Zhen-Qiang; Li, Hong-Wei; Zhou, Zheng; Guo, Guang-Can; Han, Zheng-Fu

    2012-03-15

    We report a demonstration of quantum key distribution (QKD) over a standard telecom fiber exceeding 50 dB in loss and 250 km in length. The differential phase shift QKD protocol was chosen and implemented with a 2 GHz system clock rate. By careful optimization of the 1 bit delayed Faraday-Michelson interferometer and the use of the superconducting single photon detector (SSPD), we achieved a quantum bit error rate below 2% when the fiber length was no more than 205 km, and of 3.45% for a 260 km fiber with 52.9 dB loss. We also improved the quantum efficiency of SSPD to obtain a high key rate for 50 km length.

  2. Central Field Index Versus Visual Field Index for Central Visual Function in Stable Glaucoma.

    PubMed

    Rao, Aparna; Padhy, Debananda; Mudunuri, Harika; Roy, Avik K; Sarangi, Sarada P; Das, Gopinath

    2017-01-01

    To compare the variability of central field index (CFI) versus visual field index (VFI) in stable glaucoma with central fixation involvement. For this retrospective study, we identified multiple visual fields (VFs) of patients with repeatable central fixation involvement on Humphrey VFs (24-2 and 10-2 program) which were stable (clinically and on VFs) over a very short period of 2 to 3 months. The VFI and CFI were calculated as described in earlier reports. We graded the fields as early [mean deviation (MD)>-6 dB], moderate (-6.1 to -12 dB), and severe glaucoma (<-12 dB) based on MD on 24-2 program. The variability of CFI and VFI between visits and across different severity of glaucoma was compared. Relation of the divergence to field indices and clinical parameters were assessed. The intervisit difference for VFI was greater than CFI ranging from -4% to 9% versus -1% to 8% in early (P=0.9), -13% to 18% versus -6% to 17% (P=0.056) in moderate, and -21% to 19% versus -9% to 9% (P<0.001) in severe glaucoma. The CFI within each group had narrower range than VFI with maximum range in severe glaucoma (33% to 95%). The divergence of CFI from VFI started at MD 24-2 beyond (worse) -10 dB. This difference between CFI and VFI was associated significantly with number of points with P<1% on 24-2 (R=80.3%). CFI is less variable than VFI in stable eyes with fixation involvement especially in severe glaucoma indicating need for incorporating CFI calculation for monitoring advanced disease in eyes with central defects.

  3. Effect of scan quality on diagnostic accuracy of spectral-domain optical coherence tomography in glaucoma.

    PubMed

    Rao, Harsha L; Addepalli, Uday K; Yadav, Ravi K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2014-03-01

    To evaluate the effect of scan quality on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) parameters of spectral-domain optical coherence tomography (SD OCT) in glaucoma. Cross-sectional study. Two hundred fifty-two eyes of 183 control subjects (mean deviation [MD]: -1.84 dB) and 207 eyes of 159 glaucoma patients (MD: -7.31 dB) underwent ONH, RNFL, and GCC scanning with SD OCT. Scan quality of SD OCT images was based on signal strength index (SSI) values. Influence of SSI on diagnostic accuracy of SD OCT was evaluated by receiver operating characteristic (ROC) regression. Diagnostic accuracies of all SD OCT parameters were better when the SSI values were higher. This effect was statistically significant (P < .05) for ONH and RNFL but not for GCC parameters. In mild glaucoma (MD of -5 dB), area under ROC curve (AUC) for rim area, average RNFL thickness, and average GCC thickness parameters improved from 0.651, 0.678, and 0.726, respectively, at an SSI value of 30 to 0.873, 0.962, and 0.886, respectively, at an SSI of 70. AUCs of the same parameters in advanced glaucoma (MD of -15 dB) improved from 0.747, 0.890, and 0.873, respectively, at an SSI value of 30 to 0.922, 0.994, and 0.959, respectively, at an SSI of 70. Diagnostic accuracies of SD OCT parameters in glaucoma were significantly influenced by the scan quality even when the SSI values were within the manufacturer-recommended limits. These results should be considered while interpreting the SD OCT scans for glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Glaucomatous patterns in Frequency Doubling Technology (FDT) perimetry data identified by unsupervised machine learning classifiers.

    PubMed

    Bowd, Christopher; Weinreb, Robert N; Balasubramanian, Madhusudhanan; Lee, Intae; Jang, Giljin; Yousefi, Siamak; Zangwill, Linda M; Medeiros, Felipe A; Girkin, Christopher A; Liebmann, Jeffrey M; Goldbaum, Michael H

    2014-01-01

    The variational Bayesian independent component analysis-mixture model (VIM), an unsupervised machine-learning classifier, was used to automatically separate Matrix Frequency Doubling Technology (FDT) perimetry data into clusters of healthy and glaucomatous eyes, and to identify axes representing statistically independent patterns of defect in the glaucoma clusters. FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal FDT results from the UCSD-based Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES). For all eyes, VIM input was 52 threshold test points from the 24-2 test pattern, plus age. FDT mean deviation was -1.00 dB (S.D. = 2.80 dB) and -5.57 dB (S.D. = 5.09 dB) in FDT-normal eyes and FDT-abnormal eyes, respectively (p<0.001). VIM identified meaningful clusters of FDT data and positioned a set of statistically independent axes through the mean of each cluster. The optimal VIM model separated the FDT fields into 3 clusters. Cluster N contained primarily normal fields (1109/1190, specificity 93.1%) and clusters G1 and G2 combined, contained primarily abnormal fields (651/786, sensitivity 82.8%). For clusters G1 and G2 the optimal number of axes were 2 and 5, respectively. Patterns automatically generated along axes within the glaucoma clusters were similar to those known to be indicative of glaucoma. Fields located farther from the normal mean on each glaucoma axis showed increasing field defect severity. VIM successfully separated FDT fields from healthy and glaucoma eyes without a priori information about class membership, and identified familiar glaucomatous patterns of loss.

  5. Risk factors for poor visual outcome in patients with idiopathic intracranial hypertension.

    PubMed

    Wall, Michael; Falardeau, Julie; Fletcher, William A; Granadier, Robert J; Lam, Byron L; Longmuir, Reid A; Patel, Anil D; Bruce, Beau B; He, Hua; McDermott, Michael P

    2015-09-01

    Determine potential risk factors for progressive visual field loss in the Idiopathic Intracranial Hypertension Treatment Trial, a randomized placebo-controlled trial of acetazolamide in patients with idiopathic intracranial hypertension and mild visual loss concurrently receiving a low sodium, weight reduction diet. Logistic regression and classification tree analyses were used to evaluate potential risk factors for protocol-defined treatment failure (>2 dB perimetric mean deviation [PMD] change in patients with baseline PMD -2 to -3.5 dB or >3 dB PMD change with baseline PMD -3.5 to -7 dB). Seven participants (6 on diet plus placebo) met criteria for treatment failure. The odds ratio for patients with grades III to V papilledema vs those with grades I and II was 8.66 (95% confidence interval [CI] 1.65-∞, p = 0.025). A 1-unit decrease in the number of letters correct on the ETDRS (Early Treatment Diabetic Retinopathy Study) chart at baseline was associated with an increase in the odds of treatment failure by a factor of 1.16 (95% CI 1.04-1.30, p = 0.005). Compared with female participants, the odds ratio for male participants was 26.21 (95% CI 1.61-433.00, p = 0.02). The odds of treatment failure were 10.59 times higher (95% CI 1.63-116.83, p = 0.010) for patients with >30 transient visual obscurations per month vs those with ≤30 per month. Male patients, those with high-grade papilledema, and those with decreased visual acuity at baseline were more likely to experience treatment failure. All but one of these patients were treated with diet alone. These patients should be monitored closely and be considered for aggressive treatment of their idiopathic intracranial hypertension. © 2015 American Academy of Neurology.

  6. A new approach to measure visual field progression in glaucoma patients using variational bayes linear regression.

    PubMed

    Murata, Hiroshi; Araie, Makoto; Asaoka, Ryo

    2014-11-20

    We generated a variational Bayes model to predict visual field (VF) progression in glaucoma patients. This retrospective study included VF series from 911 eyes of 547 glaucoma patients as test data, and VF series from 5049 eyes of 2858 glaucoma patients as training data. Using training data, variational Bayes linear regression (VBLR) was created to predict VF progression. The performance of VBLR was compared against ordinary least-squares linear regression (OLSLR) by predicting VFs in the test dataset. The total deviation (TD) values of test patients' 11th VFs were predicted using TD values from their second to 10th VFs (VF2-10), the root mean squared error (RMSE) associated with each approach then was calculated. Similarly, mean TD (mTD) of test patients' 11th VFs was predicted using VBLR and OLSLR, and the absolute prediction errors compared. The RMSE resulting from VBLR averaged 3.9 ± 2.1 (SD) and 4.9 ± 2.6 dB for prediction based on the second to 10th VFs (VF2-10) and the second to fourth VFs (VF2-4), respectively. The RMSE resulting from OLSLR was 4.1 ± 2.0 (VF2-10) and 19.9 ± 12.0 (VF2-4) dB. The absolute prediction error (SD) for mTD using VBLR was 1.2 ± 1.3 (VF2-10) and 1.9 ± 2.0 (VF2-4) dB, while the prediction error resulting from OLSLR was 1.2 ± 1.3 (VF2-10) and 6.2 ± 6.6 (VF2-4) dB. The VBLR more accurately predicts future VF progression in glaucoma patients compared to conventional OLSLR, especially in short VF series. © ARVO.

  7. Visual field progression in glaucoma: total versus pattern deviation analyses.

    PubMed

    Artes, Paul H; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-12-01

    To compare visual field progression with total and pattern deviation analyses in a prospective longitudinal study of patients with glaucoma and healthy control subjects. A group of 101 patients with glaucoma (168 eyes) with early to moderately advanced visual field loss at baseline (average mean deviation [MD], -3.9 dB) and no clinical evidence of media opacity were selected from a prospective longitudinal study on visual field progression in glaucoma. Patients were examined with static automated perimetry at 6-month intervals for a median follow-up of 9 years. At each test location, change was established with event and trend analyses of total and pattern deviation. The event analyses compared each follow-up test to a baseline obtained from averaging the first two tests, and visual field progression was defined as deterioration beyond the 5th percentile of test-retest variability at three test locations, observed on three consecutive tests. The trend analyses were based on point-wise linear regression, and visual field progression was defined as statistically significant deterioration (P < 5%) worse than -1 dB/year at three locations, confirmed by independently omitting the last and the penultimate observation. The incidence and the time-to-progression were compared between total and pattern deviation analyses. To estimate the specificity of the progression analyses, identical criteria were applied to visual fields obtained in 102 healthy control subjects, and the rate of visual field improvement was established in the patients with glaucoma and the healthy control subjects. With both event and trend methods, pattern deviation analyses classified approximately 15% fewer eyes as having progressed than did the total deviation analyses. In eyes classified as progressing by both the total and pattern deviation methods, total deviation analyses tended to detect progression earlier than the pattern deviation analyses. A comparison of the changes observed in MD and the visual fields' general height (estimated by the 85th percentile of the total deviation values) confirmed that change in the glaucomatous eyes almost always comprised a diffuse component. Pattern deviation analyses of progression may therefore underestimate the true amount of glaucomatous visual field progression. Pattern deviation analyses of visual field progression may underestimate visual field progression in glaucoma, particularly when there is no clinical evidence of increasing media opacity. Clinicians should have access to both total and pattern deviation analyses to make informed decisions on visual field progression in glaucoma.

  8. Continuous variable quantum cryptography: beating the 3 dB loss limit.

    PubMed

    Silberhorn, Ch; Ralph, T C; Lütkenhaus, N; Leuchs, G

    2002-10-14

    We demonstrate that secure quantum key distribution systems based on continuous variable implementations can operate beyond the apparent 3 dB loss limit that is implied by the beam splitting attack. The loss limit was established for standard minimum uncertainty states such as coherent states. We show that, by an appropriate postselection mechanism, we can enter a region where Eve's knowledge on Alice's key falls behind the information shared between Alice and Bob, even in the presence of substantial losses.

  9. Neuroinformatics Database (NiDB) – A Modular, Portable Database for the Storage, Analysis, and Sharing of Neuroimaging Data

    PubMed Central

    Anderson, Beth M.; Stevens, Michael C.; Glahn, David C.; Assaf, Michal; Pearlson, Godfrey D.

    2013-01-01

    We present a modular, high performance, open-source database system that incorporates popular neuroimaging database features with novel peer-to-peer sharing, and a simple installation. An increasing number of imaging centers have created a massive amount of neuroimaging data since fMRI became popular more than 20 years ago, with much of that data unshared. The Neuroinformatics Database (NiDB) provides a stable platform to store and manipulate neuroimaging data and addresses several of the impediments to data sharing presented by the INCF Task Force on Neuroimaging Datasharing, including 1) motivation to share data, 2) technical issues, and 3) standards development. NiDB solves these problems by 1) minimizing PHI use, providing a cost effective simple locally stored platform, 2) storing and associating all data (including genome) with a subject and creating a peer-to-peer sharing model, and 3) defining a sample, normalized definition of a data storage structure that is used in NiDB. NiDB not only simplifies the local storage and analysis of neuroimaging data, but also enables simple sharing of raw data and analysis methods, which may encourage further sharing. PMID:23912507

  10. Matrix Summaries Improve Research Reports: Secondary Analyses Using Published Literature

    ERIC Educational Resources Information Center

    Zientek, Linda Reichwein; Thompson, Bruce

    2009-01-01

    Correlation matrices and standard deviations are the building blocks of many of the commonly conducted analyses in published research, and AERA and APA reporting standards recommend their inclusion when reporting research results. The authors argue that the inclusion of correlation/covariance matrices, standard deviations, and means can enhance…

  11. 30 CFR 74.8 - Measurement, accuracy, and reliability requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... concentration, as defined by the relative standard deviation of the distribution of measurements. The relative standard deviation shall be less than 0.1275 without bias for both full-shift measurements of 8 hours or... Standards, Regulations, and Variances, 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209-3939...

  12. Off-nadir antenna bias correction using Amazon rain forest sigma deg data. [Brazil

    NASA Technical Reports Server (NTRS)

    Birrer, I. J.; Bracalente, E. M.; Dome, G. J.; Sweet, J.; Berthold, G.; Moore, R. K. (Principal Investigator)

    1981-01-01

    The radar response from the Amazon rain forest was studied to determine the suitability of this region for use as a standard target to calibrate a scatterometer like that proposed for the National Ocean Satellite System (NOSS). Backscattering observations made by the SEASAT-1 scatterometer system show the Amazon rain forest to be a homogeneous, azimuthally-isotropic, radar target which is insensitive to polarization. The variation with angle of incidence may be adequately modeled as sigma deg (dB) = alpha theta + beta with typical values for the incidence-angle coefficient from 0.07 dB deg to 0.15 dB/deg. A small diurnal effect occurs, with measurements at sunrise being 0.5 dB to 1 dB higher than the rest of the day. Maximum likelihood estimation algorithms are presented which permit determination of relative bias and true pointing angle for each beam. Specific implementation of these algorithms for the proposed NOSS scatterometer system is also discussed.

  13. USL/DBMS NASA/PC R and D project C programming standards

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.

  14. Standard deviation index for stimulated Brillouin scattering suppression with different homogeneities.

    PubMed

    Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-10

    We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.

  15. Investigation of the relationship between aircraft noise and community annoyance in China.

    PubMed

    Guoqing, Di; Xiaoyi, Liu; Xiang, Shi; Zhengguang, Li; Qili, Lin

    2012-01-01

    A survey of community annoyance induced by aircraft noise exposure was carried out around Hangzhou Xiaoshan International Airport. To investigate the relationship curves between aircraft noise and the percentage of "highly annoyed" persons in China and also to get annoyance threshold of aircraft noise in China. Noise annoyance induced by aircraft noise exposure was assessed by 764 local residents around the airport using the International Commission on Biological Effect of Noise (ICBEN) scale. The status quo of aircraft noise pollution was measured by setting up 39 monitoring points. The interpolation was used to estimate the weighted effective continuous perceived noise levels (LWECPN) in different areas around the airport, and the graph of equal noise level contour was drawn. The membership function was used to calculate the annoyance threshold of aircraft noise. Data were analyzed using SPSS 16.0 and Origin 8.0. The results showed that if LWECPN was 64.3 dB (Ldn was 51.4 dB), then 15% respondents were highly annoyed. If LWECPN was 68.1 dB (Ldn was 55.0 dB), then 25% respondents were highly annoyed. The annoyance threshold of aircraft noise (LWECPN) was 73.7 dB, while the annoyance threshold of a single flight incident instantaneous noise level (LAmax) was 72.9 dB. People around the airport had felt annoyed before the aircraft noise LWECPN reached the standard limit.

  16. Validation of a rotational coherent anti-Stokes Raman spectroscopy model for carbon dioxide using high-resolution detection in the temperature range 294-1143 K.

    PubMed

    Vestin, Fredrik; Nilsson, Kristin; Bengtsson, Per-Erik

    2008-04-10

    Experiments were performed in the temperature range of 294-1143 K in pure CO(2) using high-resolution rotational coherent anti-Stokes Raman spectroscopy (CARS), in the dual-broadband approach. Experimental single-shot spectra were recorded with high spectral resolution using a single-mode Nd:YAG laser and a relay imaging lens system on the exit of a 1 m spectrometer. A theoretical rotational CARS model for CO(2) was developed for evaluation of the experimental spectra. The evaluated mean temperatures of the recorded single-shot dual-broadband rotational coherent anti-Stokes Raman spectroscopy (DB-RCARS) spectra using this model showed good agreement with thermocouple temperatures, and the relative standard deviation of evaluated single-shot temperatures was generally 2-3%. Simultaneous thermometry and relative CO(2)/N(2)-concentration measurements were demonstrated in the product gas of premixed laminar CO/air flames at atmospheric pressure. Although the model proved to be accurate for thermometry up to 1143 K, limitations were observed at flame temperatures where temperatures were overestimated and relative CO(2)/N(2) concentrations were underestimated. Potential sources for these discrepancies are discussed.

  17. Automatic arrival time detection for earthquakes based on Modified Laplacian of Gaussian filter

    NASA Astrophysics Data System (ADS)

    Saad, Omar M.; Shalaby, Ahmed; Samy, Lotfy; Sayed, Mohammed S.

    2018-04-01

    Precise identification of onset time for an earthquake is imperative in the right figuring of earthquake's location and different parameters that are utilized for building seismic catalogues. P-wave arrival detection of weak events or micro-earthquakes cannot be precisely determined due to background noise. In this paper, we propose a novel approach based on Modified Laplacian of Gaussian (MLoG) filter to detect the onset time even in the presence of very weak signal-to-noise ratios (SNRs). The proposed algorithm utilizes a denoising-filter algorithm to smooth the background noise. In the proposed algorithm, we employ the MLoG mask to filter the seismic data. Afterward, we apply a Dual-threshold comparator to detect the onset time of the event. The results show that the proposed algorithm can detect the onset time for micro-earthquakes accurately, with SNR of -12 dB. The proposed algorithm achieves an onset time picking accuracy of 93% with a standard deviation error of 0.10 s for 407 field seismic waveforms. Also, we compare the results with short and long time average algorithm (STA/LTA) and the Akaike Information Criterion (AIC), and the proposed algorithm outperforms them.

  18. A 128-Tap Highly Tunable CMOS IF Finite Impulse Response Filter for Pulsed Radar Applications

    DOE PAGES

    Mincey, John Stephen; Su, Eric C.; Silva-Martinez, Jose; ...

    2018-02-28

    A configurable-bandwidth (BW) filter is presented in this paper for pulsed radar applications. Also, to eliminate dispersion effects in the received waveform, a finite impulse response (FIR) topology is proposed, which has a measured standard deviation of an in-band group delay of 11 ns that is primarily dominated by the inherent, fully predictable delay introduced by the sample-and-hold. The filter operates at an IF of 20 MHz, and is tunable in BW from 1.5 to 15 MHz, which makes it optimal to be used with varying pulse widths in the radar. Employing a total of 128 taps, the FIR filtermore » provides greater than 50-dB sharp attenuation in the stopband in order to minimize all out-of-band noise in the low signal-to-noise received radar signal. Fabricated in a 0.18-μm silicon on insulator CMOS process, the proposed filter consumes approximately 3.5 mW/tap with a 1.8-V supply. Finally, a 20-MHz two-tone measurement with 200-kHz tone separation shows IIP3 greater than 8.5 dBm.« less

  19. Performance of a Ka-band transponder breadboard for deep-space applications

    NASA Technical Reports Server (NTRS)

    Mysoor, N. R.; Lane, J. P.; Kayalar, S.; Kermode, A. W.

    1995-01-01

    This article summarizes the design concepts applied in the development of and advanced Ka-band (34.4 GHz/32 GHz) transponder breadboard for the next generation of space communications systems applications. The selected architecture upgrades the X-band (7.2 GHz/8.4 GHz) deep-space transponder (DST) to provide Da-band up/Ka- and X-band down capability. The Ka-band transponder breadboard incorporates several state-of-the-art components, including sampling mixers, a Ka-band dielectric resonator oscillator, and microwave monolithic integrated circuits (MMICs). The MMICs that were tested in the breadboard include upconverters, downconverters, automatic gain control circuits, mixers, phase modulators, and amplifiers. The measured receiver dynamic range, tracking range, acquisition rate, static phase error, and phase jitter characteristics of the Ka-band breadboard interfaced to the advanced engineering model X-band DST are in good agreement with the expected performance. The results show a receiver tracking threshold of -149 dBm with a dynamic range of 80 dB and a downlink phase jitter of 7 deg rms. The analytical results of phase noise and Allan standard deviation are in good agreement with the experimental results.

  20. A 128-Tap Highly Tunable CMOS IF Finite Impulse Response Filter for Pulsed Radar Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mincey, John Stephen; Su, Eric C.; Silva-Martinez, Jose

    A configurable-bandwidth (BW) filter is presented in this paper for pulsed radar applications. Also, to eliminate dispersion effects in the received waveform, a finite impulse response (FIR) topology is proposed, which has a measured standard deviation of an in-band group delay of 11 ns that is primarily dominated by the inherent, fully predictable delay introduced by the sample-and-hold. The filter operates at an IF of 20 MHz, and is tunable in BW from 1.5 to 15 MHz, which makes it optimal to be used with varying pulse widths in the radar. Employing a total of 128 taps, the FIR filtermore » provides greater than 50-dB sharp attenuation in the stopband in order to minimize all out-of-band noise in the low signal-to-noise received radar signal. Fabricated in a 0.18-μm silicon on insulator CMOS process, the proposed filter consumes approximately 3.5 mW/tap with a 1.8-V supply. Finally, a 20-MHz two-tone measurement with 200-kHz tone separation shows IIP3 greater than 8.5 dBm.« less

  1. Reclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.

    PubMed

    Mönter, Vera M; Crabb, David P; Artes, Paul H

    2017-02-01

    Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Thirty patients with glaucoma (median age 68, range 59-83 years; median Mean Deviation -8.0, range -16.3-0.1 dB) performed AKP and static automated perimetry (SAP) (German Adaptive Threshold Estimation strategy, 24-2 test). Automated kinetic perimetry consisted of a fully automated measurement of a single isopter (III.1.e). Central and peripheral visual fields were measured twice on the same day. Peripheral and central visual fields were only moderately related (Spearman's ρ, 0.51). Approximately 90% of test-retest differences in mean isopter radius were < ±4 deg. Relative to the range of measurements in this sample, the retest variability of AKP was similar to that of SAP. Patients with similar central visual field loss can have strikingly different peripheral visual fields, and therefore measuring the peripheral visual field may add clinically valuable information.

  2. figure1.nc

    EPA Pesticide Factsheets

    NetCDF file of the SREF standard deviation of wind speed and direction that was used to inject variability in the FDDA input.variable U_NDG_OLD contains standard deviation of wind speed (m/s)variable V_NDG_OLD contains the standard deviation of wind direction (deg)This dataset is associated with the following publication:Gilliam , R., C. Hogrefe , J. Godowitch, S. Napelenok , R. Mathur , and S.T. Rao. Impact of inherent meteorology uncertainty on air quality model predictions. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES. American Geophysical Union, Washington, DC, USA, 120(23): 12,259–12,280, (2015).

  3. Novel spot size converter for coupling standard single mode fibers to SOI waveguides

    NASA Astrophysics Data System (ADS)

    Sisto, Marco Michele; Fisette, Bruno; Paultre, Jacques-Edmond; Paquet, Alex; Desroches, Yan

    2016-03-01

    We have designed and numerically simulated a novel spot size converter for coupling standard single mode fibers with 10.4μm mode field diameter to 500nm × 220nm SOI waveguides. Simulations based on the eigenmode expansion method show a coupling loss of 0.4dB at 1550nm for the TE mode at perfect alignment. The alignment tolerance on the plane normal to the fiber axis is evaluated at +/-2.2μm for <=1dB excess loss, which is comparable to the alignment tolerance between two butt-coupled standard single mode fibers. The converter is based on a cross-like arrangement of SiOxNy waveguides immersed in a 12μm-thick SiO2 cladding region deposited on top of the SOI chip. The waveguides are designed to collectively support a single degenerate mode for TE and TM polarizations. This guided mode features a large overlap to the LP01 mode of standard telecom fibers. Along the spot size converter length (450μm), the mode is first gradually confined in a single SiOxNy waveguide by tapering its width. Then, the mode is adiabatically coupled to a SOI waveguide underneath the structure through a SOI inverted taper. The shapes of SiOxNy and SOI tapers are optimized to minimize coupling loss and structure length, and to ensure adiabatic mode evolution along the structure, thus improving the design robustness to fabrication process errors. A tolerance analysis based on conservative microfabrication capabilities suggests that coupling loss penalty from fabrication errors can be maintained below 0.3dB. The proposed spot size converter is fully compliant to industry standard microfabrication processes available at INO.

  4. 75 FR 67093 - Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0517] Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... from the requirements of the standards of identity issued under section 401 of the Federal Food, Drug...

  5. 78 FR 2273 - Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-P-1189] Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... interstate shipment of experimental packs of food varying from the requirements of standards of identity...

  6. Upgraded FAA Airfield Capacity Model. Volume 2. Technical Description of Revisions

    DTIC Science & Technology

    1981-02-01

    the threshold t k a the time at which departure k is released FIGURE 3-1 TIME AXIS DIAGRAM OF SINGLE RUNWAY OPERATIONS 3-2 J"- SIGMAR the standard...standard deviation of the interarrival time. SIGMAR - the standard deviation of the arrival runway occupancy time. A-5 SINGLE - program subroutine for

  7. Methods of editing cloud and atmospheric layer affected pixels from satellite data

    NASA Technical Reports Server (NTRS)

    Nixon, P. R.; Wiegand, C. L.; Richardson, A. J.; Johnson, M. P. (Principal Investigator)

    1982-01-01

    Subvisible cirrus clouds (SCi) were easily distinguished in mid-infrared (MIR) TIROS-N daytime data from south Texas and northeast Mexico. The MIR (3.55-3.93 micrometer) pixel digital count means of the SCi affected areas were more than 3.5 standard deviations on the cold side of the scene means. (These standard deviations were made free of the effects of unusual instrument error by factoring out the Ch 3 MIR noise on the basis of detailed examination of noisy and noise-free pixels). SCi affected areas in the IR Ch 4 (10.5-11.5 micrometer) appeared cooler than the general scene, but were not as prominent as in Ch 3, being less than 2 standard deviations from the scene mean. Ch 3 and 4 standard deviations and coefficients of variation are not reliable indicators, by themselves, of the presence of SCi because land features can have similar statistical properties.

  8. A Taxonomy of Delivery and Documentation Deviations During Delivery of High-Fidelity Simulations.

    PubMed

    McIvor, William R; Banerjee, Arna; Boulet, John R; Bekhuis, Tanja; Tseytlin, Eugene; Torsher, Laurence; DeMaria, Samuel; Rask, John P; Shotwell, Matthew S; Burden, Amanda; Cooper, Jeffrey B; Gaba, David M; Levine, Adam; Park, Christine; Sinz, Elizabeth; Steadman, Randolph H; Weinger, Matthew B

    2017-02-01

    We developed a taxonomy of simulation delivery and documentation deviations noted during a multicenter, high-fidelity simulation trial that was conducted to assess practicing physicians' performance. Eight simulation centers sought to implement standardized scenarios over 2 years. Rules, guidelines, and detailed scenario scripts were established to facilitate reproducible scenario delivery; however, pilot trials revealed deviations from those rubrics. A taxonomy with hierarchically arranged terms that define a lack of standardization of simulation scenario delivery was then created to aid educators and researchers in assessing and describing their ability to reproducibly conduct simulations. Thirty-six types of delivery or documentation deviations were identified from the scenario scripts and study rules. Using a Delphi technique and open card sorting, simulation experts formulated a taxonomy of high-fidelity simulation execution and documentation deviations. The taxonomy was iteratively refined and then tested by 2 investigators not involved with its development. The taxonomy has 2 main classes, simulation center deviation and participant deviation, which are further subdivided into as many as 6 subclasses. Inter-rater classification agreement using the taxonomy was 74% or greater for each of the 7 levels of its hierarchy. Cohen kappa calculations confirmed substantial agreement beyond that expected by chance. All deviations were classified within the taxonomy. This is a useful taxonomy that standardizes terms for simulation delivery and documentation deviations, facilitates quality assurance in scenario delivery, and enables quantification of the impact of deviations upon simulation-based performance assessment.

  9. Long-term fluctuation of standard automatic perimetry, pulsar perimetry and frequency-doubling technology in early glaucoma diagnosis.

    PubMed

    Gonzalez-Hernandez, M; de la Rosa, M Gonzalez; de la Vega, R Rodriguez; Hernandez-Vidal, A

    2007-01-01

    Analyze the stability and accuracy of 3 perimetric techniques. A total of 104 stable eyes (65 subjects) with ocular hypertension and early glaucoma [group G, mean defect = 1.08 dB, SD = 2.0, in standard TOP automatic perimetry (SAP)] were examined 5 times during 18 months using: (a) SAP; (b) Pulsar temporal modulation perimetry (T30W), and (c) frequency-doubling technology (FDT N30). Ninety eyes from 90 normal controls were compared with the first set of examinations of group G. The learning effect was minimal in the 3 techniques but higher in Pulsar (1.0 src, p < 0.05) than in SAP and FDT (0.4 dB). Long-term fluctuation (F) was significantly higher in FDT (3.1 dB, SD = 1.4, p < 0.0001) than in SAP (2.3 dB, SD = 1.1) and in Pulsar (1.9 src, SD = 0.7). Pulsar and FDT reduce F when increasing the number of examinations. F seems equivalent in SAP and FDT and lower in Pulsar, considering small-scale differences of the 3 perimeters. A slight learning effect would be expected on FDT and SAP in patients with previous experience with SAP. The stability and sensitivity of Pulsar is greater than on the other 2 systems. For early diagnosis of glaucoma it is essential to prove the reproducibility and coincidence of perimetric results. (c) 2007 S. Karger AG, Basel.

  10. Automated audiometry using apple iOS-based application technology.

    PubMed

    Foulad, Allen; Bui, Peggy; Djalilian, Hamid

    2013-11-01

    The aim of this study is to determine the feasibility of an Apple iOS-based automated hearing testing application and to compare its accuracy with conventional audiometry. Prospective diagnostic study. Setting Academic medical center. An iOS-based software application was developed to perform automated pure-tone hearing testing on the iPhone, iPod touch, and iPad. To assess for device variations and compatibility, preliminary work was performed to compare the standardized sound output (dB) of various Apple device and headset combinations. Forty-two subjects underwent automated iOS-based hearing testing in a sound booth, automated iOS-based hearing testing in a quiet room, and conventional manual audiometry. The maximum difference in sound intensity between various Apple device and headset combinations was 4 dB. On average, 96% (95% confidence interval [CI], 91%-100%) of the threshold values obtained using the automated test in a sound booth were within 10 dB of the corresponding threshold values obtained using conventional audiometry. When the automated test was performed in a quiet room, 94% (95% CI, 87%-100%) of the threshold values were within 10 dB of the threshold values obtained using conventional audiometry. Under standardized testing conditions, 90% of the subjects preferred iOS-based audiometry as opposed to conventional audiometry. Apple iOS-based devices provide a platform for automated air conduction audiometry without requiring extra equipment and yield hearing test results that approach those of conventional audiometry.

  11. Simulation-based estimation of mean and standard deviation for meta-analysis via Approximate Bayesian Computation (ABC).

    PubMed

    Kwon, Deukwoo; Reis, Isildinha M

    2015-08-12

    When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.

  12. A chaotic modified-DFT encryption scheme for physical layer security and PAPR reduction in OFDM-PON

    NASA Astrophysics Data System (ADS)

    Fu, Xiaosong; Bi, Meihua; Zhou, Xuefang; Yang, Guowei; Li, Qiliang; Zhou, Zhao; Yang, Xuelin

    2018-05-01

    This letter proposes a modified discrete Fourier transform (DFT) encryption scheme with multi-dimensional chaos for the physical layer security and peak-to-average power ratio (PAPR) reduction in orthogonal frequency division multiplexing passive optical network (OFDM-PON) system. This multiple-fold encryption algorithm is mainly composed by using the column vectors permutation and the random phase encryption in the standard DFT matrix, which can create ∼10551 key space. The transmission of ∼10 Gb/s encrypted OFDM signal is verified over 20-km standard single mode fiber (SMF). Moreover, experimental results show that, the proposed scheme can achieve ∼2.6-dB PAPR reduction and ∼1-dB improvement of receiver sensitivity if compared with the common OFDM-PON.

  13. On Teaching about the Coefficient of Variation in Introductory Statistics Courses

    ERIC Educational Resources Information Center

    Trafimow, David

    2014-01-01

    The standard deviation is related to the mean by virtue of the coefficient of variation. Teachers of statistics courses can make use of that fact to make the standard deviation more comprehensible for statistics students.

  14. Informatics in radiology: use of CouchDB for document-based storage of DICOM objects.

    PubMed

    Rascovsky, Simón J; Delgado, Jorge A; Sanz, Alexander; Calvo, Víctor D; Castrillón, Gabriel

    2012-01-01

    Picture archiving and communication systems traditionally have depended on schema-based Structured Query Language (SQL) databases for imaging data management. To optimize database size and performance, many such systems store a reduced set of Digital Imaging and Communications in Medicine (DICOM) metadata, discarding informational content that might be needed in the future. As an alternative to traditional database systems, document-based key-value stores recently have gained popularity. These systems store documents containing key-value pairs that facilitate data searches without predefined schemas. Document-based key-value stores are especially suited to archive DICOM objects because DICOM metadata are highly heterogeneous collections of tag-value pairs conveying specific information about imaging modalities, acquisition protocols, and vendor-supported postprocessing options. The authors used an open-source document-based database management system (Apache CouchDB) to create and test two such databases; CouchDB was selected for its overall ease of use, capability for managing attachments, and reliance on HTTP and Representational State Transfer standards for accessing and retrieving data. A large database was created first in which the DICOM metadata from 5880 anonymized magnetic resonance imaging studies (1,949,753 images) were loaded by using a Ruby script. To provide the usual DICOM query functionality, several predefined "views" (standard queries) were created by using JavaScript. For performance comparison, the same queries were executed in both the CouchDB database and a SQL-based DICOM archive. The capabilities of CouchDB for attachment management and database replication were separately assessed in tests of a similar, smaller database. Results showed that CouchDB allowed efficient storage and interrogation of all DICOM objects; with the use of information retrieval algorithms such as map-reduce, all the DICOM metadata stored in the large database were searchable with only a minimal increase in retrieval time over that with the traditional database management system. Results also indicated possible uses for document-based databases in data mining applications such as dose monitoring, quality assurance, and protocol optimization. RSNA, 2012

  15. Evaluation of Glaucoma Progression in Large-Scale Clinical Data: The Japanese Archive of Multicentral Databases in Glaucoma (JAMDIG).

    PubMed

    Fujino, Yuri; Asaoka, Ryo; Murata, Hiroshi; Miki, Atsuya; Tanito, Masaki; Mizoue, Shiro; Mori, Kazuhiko; Suzuki, Katsuyoshi; Yamashita, Takehiro; Kashiwagi, Kenji; Shoji, Nobuyuki

    2016-04-01

    To develop a large-scale real clinical database of glaucoma (Japanese Archive of Multicentral Databases in Glaucoma: JAMDIG) and to investigate the effect of treatment. The study included a total of 1348 eyes of 805 primary open-angle glaucoma patients with 10 visual fields (VFs) measured with 24-2 or 30-2 Humphrey Field Analyzer (HFA) and intraocular pressure (IOP) records in 10 institutes in Japan. Those with 10 reliable VFs were further identified (638 eyes of 417 patients). Mean total deviation (mTD) of the 52 test points in the 24-2 HFA VF was calculated, and the relationship between mTD progression rate and seven variables (age, mTD of baseline VF, average IOP, standard deviation (SD) of IOP, previous argon/selective laser trabeculoplasties (ALT/SLT), previous trabeculectomy, and previous trabeculotomy) was analyzed. The mTD in the initial VF was -6.9 ± 6.2 dB and the mTD progression rate was -0.26 ± 0.46 dB/year. Mean IOP during the follow-up period was 13.5 ± 2.2 mm Hg. Age and SD of IOP were related to mTD progression rate. However, in eyes with average IOP below 15 and also 13 mm Hg, only age and baseline VF mTD were related to mTD progression rate. Age and the degree of VF damage were related to future progression. Average IOP was not related to the progression rate; however, fluctuation of IOP was associated with faster progression, although this was not the case when average IOP was below 15 mm Hg.

  16. A wideband current-commutating passive mixer for multi-standard receivers in a 0.18 μm CMOS

    NASA Astrophysics Data System (ADS)

    Kuan, Bao; Xiangning, Fan; Wei, Li; Zhigong, Wang

    2013-01-01

    This paper reports a wideband passive mixer for direct conversion multi-standard receivers. A brief comparison between current-commutating passive mixers and active mixers is presented. The effect of source and load impedance on the linearity of a mixer is analyzed. Specially, the impact of the input impedance of the transimpedance amplifier (TIA), which acts as the load impedance of a mixer, is investigated in detail. The analysis is verified by a passive mixer implemented with 0.18 μm CMOS technology. The circuit is inductorless and can operate over a broad frequency range. On wafer measurements show that, with radio frequency (RF) ranges from 700 MHz to 2.3 GHz, the mixer achieves 21 dB of conversion voltage gain with a -1 dB intermediate frequency (IF) bandwidth of 10 MHz. The measured IIP3 is 9 dBm and the measured double-sideband noise figure (NF) is 10.6 dB at 10 MHz output. The chip occupies an area of 0.19 mm2 and drains a current of 5.5 mA from a 1.8 V supply.

  17. A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY

    EPA Science Inventory

    Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...

  18. Histogram-based quantitative evaluation of endobronchial ultrasonography images of peripheral pulmonary lesion.

    PubMed

    Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi

    2015-01-01

    Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.

  19. Role of the standard deviation in the estimation of benchmark doses with continuous data.

    PubMed

    Gaylor, David W; Slikker, William

    2004-12-01

    For continuous data, risk is defined here as the proportion of animals with values above a large percentile, e.g., the 99th percentile or below the 1st percentile, for the distribution of values among control animals. It is known that reducing the standard deviation of measurements through improved experimental techniques will result in less stringent (higher) doses for the lower confidence limit on the benchmark dose that is estimated to produce a specified risk of animals with abnormal levels for a biological effect. Thus, a somewhat larger (less stringent) lower confidence limit is obtained that may be used as a point of departure for low-dose risk assessment. It is shown in this article that it is important for the benchmark dose to be based primarily on the standard deviation among animals, s(a), apart from the standard deviation of measurement errors, s(m), within animals. If the benchmark dose is incorrectly based on the overall standard deviation among average values for animals, which includes measurement error variation, the benchmark dose will be overestimated and the risk will be underestimated. The bias increases as s(m) increases relative to s(a). The bias is relatively small if s(m) is less than one-third of s(a), a condition achieved in most experimental designs.

  20. Statistical models for estimating daily streamflow in Michigan

    USGS Publications Warehouse

    Holtschlag, D.J.; Salehi, Habib

    1992-01-01

    Statistical models for estimating daily streamflow were analyzed for 25 pairs of streamflow-gaging stations in Michigan. Stations were paired by randomly choosing a station operated in 1989 at which 10 or more years of continuous flow data had been collected and at which flow is virtually unregulated; a nearby station was chosen where flow characteristics are similar. Streamflow data from the 25 randomly selected stations were used as the response variables; streamflow data at the nearby stations were used to generate a set of explanatory variables. Ordinary-least squares regression (OLSR) equations, autoregressive integrated moving-average (ARIMA) equations, and transfer function-noise (TFN) equations were developed to estimate the log transform of flow for the 25 randomly selected stations. The precision of each type of equation was evaluated on the basis of the standard deviation of the estimation errors. OLSR equations produce one set of estimation errors; ARIMA and TFN models each produce l sets of estimation errors corresponding to the forecast lead. The lead-l forecast is the estimate of flow l days ahead of the most recent streamflow used as a response variable in the estimation. In this analysis, the standard deviation of lead l ARIMA and TFN forecast errors were generally lower than the standard deviation of OLSR errors for l < 2 days and l < 9 days, respectively. Composite estimates were computed as a weighted average of forecasts based on TFN equations and backcasts (forecasts of the reverse-ordered series) based on ARIMA equations. The standard deviation of composite errors varied throughout the length of the estimation interval and generally was at maximum near the center of the interval. For comparison with OLSR errors, the mean standard deviation of composite errors were computed for intervals of length 1 to 40 days. The mean standard deviation of length-l composite errors were generally less than the standard deviation of the OLSR errors for l < 32 days. In addition, the composite estimates ensure a gradual transition between periods of estimated and measured flows. Model performance among stations of differing model error magnitudes were compared by computing ratios of the mean standard deviation of the length l composite errors to the standard deviation of OLSR errors. The mean error ratio for the set of 25 selected stations was less than 1 for intervals l < 32 days. Considering the frequency characteristics of the length of intervals of estimated record in Michigan, the effective mean error ratio for intervals < 30 days was 0.52. Thus, for intervals of estimation of 1 month or less, the error of the composite estimate is substantially lower than error of the OLSR estimate.

  1. Value of Microperimetry in Detecting Early Retinal Toxicity of Hydroxychloroquine in Children with Juvenile Systemic Lupus Erythematosus.

    PubMed

    Youssef, Maha M; El-Fayoumi, Dina; Sidky, Mohamed Karim; Hegazy, Ahmed I; Marzouk, Huda; Eltanamly, Rasha M

    2017-01-01

    To evaluate retinal sensitivity in children who are on hydroxychloroquine (HCQ) for systemic lupus erythematosus using microperimetry and compare the results with those of the Humphrey visual field (HVF) 10-2 and spectral-domain optical coherence tomography (SD-OCT). A case-control cross-sectional study including 19 patients (less than 18 years old) on HCQ for at least 5 years. Controls were 21 normal children. Participants underwent a complete ophthalmic examination, then were investigated using HVF 10-2, SD-OCT, and microperimetry. Ocular examination revealed no abnormalities. The overall mean microperimetry sensitivity of the patients (15.75 dB) was not significantly different from that of the controls (16.35 dB). The HVF 10-2 showed a significant difference in the mean deviation of the patients. Conclusions and Message: Microperimetry was not more revealing than HVF 10-2 and SD-OCT. Larger studies are required to compare the diagnostic accuracy of screening modalities of retinal toxicity in children on HCQ. © 2017 S. Karger AG, Basel.

  2. A 205GHz Amplifier in 90nm CMOS Technology

    DTIC Science & Technology

    2017-03-01

    San Jose State University San Jose, CA, USA       Abstract: This paper presents a 205GHz amplifier drawing 43.4mA from a 0.9V power supply with...10.5dB power gain, Psat of -1.6dBm, and P1dB ≈ -5.8dBm in a standard 90nm CMOS process. Moreover, the design employs internal (layout-based) /external...reported in [2]. In this paper, two neutralization techniques, internal and external approaches, have been implemented to achieve higher power

  3. An overview on integrated data system for archiving and sharing marine geology and geophysical data in Korea Institute of Ocean Science & Technology (KIOST)

    NASA Astrophysics Data System (ADS)

    Choi, Sang-Hwa; Kim, Sung Dae; Park, Hyuk Min; Lee, SeungHa

    2016-04-01

    We established and have operated an integrated data system for managing, archiving and sharing marine geology and geophysical data around Korea produced from various research projects and programs in Korea Institute of Ocean Science & Technology (KIOST). First of all, to keep the consistency of data system with continuous data updates, we set up standard operating procedures (SOPs) for data archiving, data processing and converting, data quality controls, and data uploading, DB maintenance, etc. Database of this system comprises two databases, ARCHIVE DB and GIS DB for the purpose of this data system. ARCHIVE DB stores archived data as an original forms and formats from data providers for data archive and GIS DB manages all other compilation, processed and reproduction data and information for data services and GIS application services. Relational data management system, Oracle 11g, adopted for DBMS and open source GIS techniques applied for GIS services such as OpenLayers for user interface, GeoServer for application server, PostGIS and PostgreSQL for GIS database. For the sake of convenient use of geophysical data in a SEG Y format, a viewer program was developed and embedded in this system. Users can search data through GIS user interface and save the results as a report.

  4. Israel Marine Bio-geographic Database (ISRAMAR-BIO)

    NASA Astrophysics Data System (ADS)

    Greengrass, Eyal; Krivenko, Yevgeniya; Ozer, Tal; Ben Yosef, Dafna; Tom, Moshe; Gertman, Isaac

    2015-04-01

    The knowledge of the space/time variations of species is the basis for any ecological investigations. While historical observations containing integral concentrations of biological parameters (chlorophyll, abundance, biomass…) are organized partly in ISRAMAR Cast Database, the taxon-specific data collected in Israel has not been sufficiently organized. This has been hindered by the lack of standards, variability of methods and complexity of biological data formalization. The ISRAMAR-BIO DB was developed to store various types of historical and future available information related to marine species observations and related metadata. Currently the DB allows to store biological data acquired by the following sampling devices such as: van veer grab, box corer, sampling bottles, nets (plankton, trawls and fish), quadrates, and cameras. The DB's logical unit is information regarding a specimen (taxa name, barcode, image), related attributes (abundance, size, age, contaminants…), habitat description, sampling device and method, time and space of sampling, responsible organization and scientist, source of information (cruise, project and publication). The following standardization of specimen and attributes naming were implemented: Taxonomy according to World Register of Marine Species (WoRMS: http://www.marinespecies.org). Habitat description according to Coastal and Marine Ecological Classification Standards (CMECS: http://www.cmecscatalog.org) Parameter name; Unit; Device name; Developmental stage; Institution name; Country name; Marine region according to SeaDataNet Vocabularies (http://www.seadatanet.org/Standards-Software/Common-Vocabularies). This system supports two types of data submission procedures, which support the above stated data structure. The first is a downloadable excel file with drop-down fields based on the ISRAMAR-BIO vocabularies. The file is filled and uploaded online by the data contributor. Alternatively, the same dataset can be assembled by filling online forms and then submitted to the DB. Online access to the ISRAMAR-BIO is available through taxon search page, where one can get both biological and geographical data regarding a certain taxon. Further development of the online data access is ongoing. It will include interactive geographical map interface where data may be queried, analyzed and downloaded.

  5. Apparent source levels and active communication space of whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in the Pearl River Estuary and Beibu Gulf, China

    PubMed Central

    Wang, Zhi-Tao; W.L. Au, Whitlow; Rendell, Luke; Wu, Hai-Ping; Wu, Yu-Ping; Liu, Jian-Chang; Duan, Guo-Qin; Cao, Han-Jiang

    2016-01-01

    Background. Knowledge of species-specific vocalization characteristics and their associated active communication space, the effective range over which a communication signal can be detected by a conspecific, is critical for understanding the impacts of underwater acoustic pollution, as well as other threats. Methods. We used a two-dimensional cross-shaped hydrophone array system to record the whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in shallow-water environments of the Pearl River Estuary (PRE) and Beibu Gulf (BG), China. Using hyperbolic position fixing, which exploits time differences of arrival of a signal between pairs of hydrophone receivers, we obtained source location estimates for whistles with good signal-to-noise ratio (SNR ≥10 dB) and not polluted by other sounds and back-calculated their apparent source levels (ASL). Combining with the masking levels (including simultaneous noise levels, masking tonal threshold, and the Sousa auditory threshold) and the custom made site-specific sound propagation models, we further estimated their active communication space (ACS). Results. Humpback dolphins produced whistles with average root-mean-square ASL of 138.5 ± 6.8 (mean ± standard deviation) and 137.2 ± 7.0 dB re 1 µPa in PRE (N = 33) and BG (N = 209), respectively. We found statistically significant differences in ASLs among different whistle contour types. The mean and maximum ACS of whistles were estimated to be 14.7 ± 2.6 (median ± quartile deviation) and 17.1± 3.5 m in PRE, and 34.2 ± 9.5 and 43.5 ± 12.2 m in BG. Using just the auditory threshold as the masking level produced the mean and maximum ACSat of 24.3 ± 4.8 and 35.7 ± 4.6 m for PRE, and 60.7 ± 18.1 and 74.3 ± 25.3 m for BG. The small ACSs were due to the high ambient noise level. Significant differences in ACSs were also observed among different whistle contour types. Discussion. Besides shedding some light for evaluating appropriate noise exposure levels and information for the regulation of underwater acoustic pollution, these baseline data can also be used for aiding the passive acoustic monitoring of dolphin populations, defining the boundaries of separate groups in a more biologically meaningful way during field surveys, and guiding the appropriate approach distance for local dolphin-watching boats and research boat during focal group following. PMID:26893973

  6. Apparent source levels and active communication space of whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in the Pearl River Estuary and Beibu Gulf, China.

    PubMed

    Wang, Zhi-Tao; W L Au, Whitlow; Rendell, Luke; Wang, Ke-Xiong; Wu, Hai-Ping; Wu, Yu-Ping; Liu, Jian-Chang; Duan, Guo-Qin; Cao, Han-Jiang; Wang, Ding

    2016-01-01

    Background. Knowledge of species-specific vocalization characteristics and their associated active communication space, the effective range over which a communication signal can be detected by a conspecific, is critical for understanding the impacts of underwater acoustic pollution, as well as other threats. Methods. We used a two-dimensional cross-shaped hydrophone array system to record the whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in shallow-water environments of the Pearl River Estuary (PRE) and Beibu Gulf (BG), China. Using hyperbolic position fixing, which exploits time differences of arrival of a signal between pairs of hydrophone receivers, we obtained source location estimates for whistles with good signal-to-noise ratio (SNR ≥10 dB) and not polluted by other sounds and back-calculated their apparent source levels (ASL). Combining with the masking levels (including simultaneous noise levels, masking tonal threshold, and the Sousa auditory threshold) and the custom made site-specific sound propagation models, we further estimated their active communication space (ACS). Results. Humpback dolphins produced whistles with average root-mean-square ASL of 138.5 ± 6.8 (mean ± standard deviation) and 137.2 ± 7.0 dB re 1 µPa in PRE (N = 33) and BG (N = 209), respectively. We found statistically significant differences in ASLs among different whistle contour types. The mean and maximum ACS of whistles were estimated to be 14.7 ± 2.6 (median ± quartile deviation) and 17.1± 3.5 m in PRE, and 34.2 ± 9.5 and 43.5 ± 12.2 m in BG. Using just the auditory threshold as the masking level produced the mean and maximum ACSat of 24.3 ± 4.8 and 35.7 ± 4.6 m for PRE, and 60.7 ± 18.1 and 74.3 ± 25.3 m for BG. The small ACSs were due to the high ambient noise level. Significant differences in ACSs were also observed among different whistle contour types. Discussion. Besides shedding some light for evaluating appropriate noise exposure levels and information for the regulation of underwater acoustic pollution, these baseline data can also be used for aiding the passive acoustic monitoring of dolphin populations, defining the boundaries of separate groups in a more biologically meaningful way during field surveys, and guiding the appropriate approach distance for local dolphin-watching boats and research boat during focal group following.

  7. Pure-Tone Audiometry With Forward Pressure Level Calibration Leads to Clinically-Relevant Improvements in Test-Retest Reliability.

    PubMed

    Lapsley Miller, Judi A; Reed, Charlotte M; Robinson, Sarah R; Perez, Zachary D

    2018-02-21

    Clinical pure-tone audiometry is conducted using stimuli delivered through supra-aural headphones or insert earphones. The stimuli are calibrated in an acoustic (average ear) coupler. Deviations in individual-ear acoustics from the coupler acoustics affect test validity, and variations in probe insertion and headphone placement affect both test validity and test-retest reliability. Using an insert earphone designed for otoacoustic emission testing, which contains a microphone and loudspeaker, an individualized in-the-ear calibration can be calculated from the ear-canal sound pressure measured at the microphone. However, the total sound pressure level (SPL) measured at the microphone may be affected by standing-wave nulls at higher frequencies, producing errors in stimulus level of up to 20 dB. An alternative is to calibrate using the forward pressure level (FPL) component, which is derived from the total SPL using a wideband acoustic immittance measurement, and represents the pressure wave incident on the eardrum. The objective of this study is to establish test-retest reliability for FPL calibration of pure-tone audiometry stimuli, compared with in-the-ear and coupler sound pressure calibrations. The authors compared standard audiometry using a modern clinical audiometer with TDH-39P supra-aural headphones calibrated in a coupler to a prototype audiometer with an ER10C earphone calibrated three ways: (1) in-the-ear using the total SPL at the microphone, (2) in-the-ear using the FPL at the microphone, and (3) in a coupler (all three are derived from the same measurement). The test procedure was similar to that commonly used in hearing-conservation programs, using pulsed-tone test frequencies at 0.5, 1, 2, 3, 4, 6, and 8 kHz, and an automated modified Hughson-Westlake audiometric procedure. Fifteen adult human participants with normal to mildly-impaired hearing were selected, and one ear from each was tested. Participants completed 10 audiograms on each system, with test-order randomly varied and with headphones and earphones refitted by the tester between tests. Fourteen of 15 ears had standing-wave nulls present between 4 and 8 kHz. The mean intrasubject SD at 6 and 8 kHz was lowest for the FPL calibration, and was comparable with the low-frequency reliability across calibration methods. This decrease in variability translates to statistically-derived significant threshold shift criteria indicating that 15 dB shifts in hearing can be reliably detected at 6 and 8 kHz using FPL-calibrated ER10C earphones, compared with 20 to 25 dB shifts using standard TDH-39P headphones with a coupler calibration. These results indicate that reliability is better with insert earphones, especially with in-the-ear FPL calibration, compared with a standard clinical audiometer with supra-aural headphones. However, in-the-ear SPL calibration should not be used due to its sensitivity to standing waves. The improvement in reliability is clinically meaningful, potentially allowing hearing-conservation programs to more confidently determine significant threshold shifts at 6 kHz-a key frequency for the early detection of noise-induced hearing loss.

  8. Flicker-defined form perimetry in glaucoma patients.

    PubMed

    Horn, Folkert K; Kremers, Jan; Mardin, Christian Y; Jünemann, Anselm G; Adler, Werner; Tornow, Ralf P

    2015-03-01

    To assess the potential of flicker-defined form (FDF) perimetry to detect functional loss in patient groups with beginning glaucoma, and to evaluate the dynamic range of the FDF stimulus in individual patients and at individual test positions. FDF perimetry and standard automated perimetry (SAP) were performed at identical test locations (adapted G1 protocol) in 60 healthy subjects and 111 glaucoma patients. All patients showed glaucomatous optic disc appearance. Grouping within the glaucoma cohort was based on SAP-performance: 33 "preperimetric" open-angle glaucoma (OAG) patients, 28 "borderline" OAG (focal defects and SAP-mean defect (MD) <2 dB), 33 "early" OAG (SAP-MD < 5 dB), 17 "advanced" OAG. All participants were experienced in psychophysical and perimetric tests. Defect values and the areas under receiver operating characteristic curves (ROC) in patient groups were statistically compared. The values of FDF-MD in the preperimetric, borderline, and early OAG group were 2.7 ± 3.4 dB, 5.5 ± 2.6 dB, and 8.5 ± 3.4 dB respectively (all significantly above normal). The percentage of patients exceeding normal FDF-MD was 27.3 %, 60.7 %, and 87.9 % respectively. The age-adjusted FDF-mean defect (MD) of the G1X-protocol was not significantly correlated with refractive error, lens opacity, pupil size, or gender. Occurrence of ceiling effects (inability to detect targets at highest contrast) showed a high correlation with visual field losses (R = 0.72, p < 0.001). Local analysis indicates that SAP losses exceeding 5 dB could not be distinguished with the FDF technique. The FDF stimulus was able to detect beginning glaucoma damage. Patients with SAP-MD values exceeding 5 dB should be monitored with conventional perimetry because of its larger dynamic range.

  9. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  10. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  11. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  12. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  13. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  14. Classification and Dose-Response Characterization of ...

    EPA Pesticide Factsheets

    Thirty years and over a billion of today’s dollars worth of pesticide registration toxicity studies, historically stored as hardcopy and scanned documents, have been digitized into highly standardized and structured toxicity data, within the U.S. Environmental Protection Agency’s (EPA) Toxicity Reference Database (ToxRefDB). The source toxicity data in ToxRefDB covers multiple study types, including subchronic, developmental, reproductive, chronic, and cancer studies, resulting in a diverse set of endpoints and toxicities. Novel approaches to chemical classification are performed as a model application of ToxRefDB and as an essential need for highly detailed chemical classifications within the EPA’s ToxCast™ research program. In order to develop predictive models and biological signatures utilizing high-throughput screening (HTS) and in vitro genomic data, endpoints and toxicities must first be identified and globally characterized for ToxCast Phase I chemicals. Secondarily, dose-response characterization within and across toxicity endpoints provide insight into key precursor toxicity events and overall endpoint relevance. Toxicity-based chemical classification and dose-response characterization utilizing ToxRefDB prioritized toxicity endpoints and differentiated toxicity outcomes across a large chemical set.

  15. 50 MHz-10 GHz low-power resistive feedback current-reuse mixer with inductive peaking for cognitive radio receiver.

    PubMed

    Vitee, Nandini; Ramiah, Harikrishnan; Chong, Wei-Keat; Tan, Gim-Heng; Kanesan, Jeevan; Reza, Ahmed Wasif

    2014-01-01

    A low-power wideband mixer is designed and implemented in 0.13 µm standard CMOS technology based on resistive feedback current-reuse (RFCR) configuration for the application of cognitive radio receiver. The proposed RFCR architecture incorporates an inductive peaking technique to compensate for gain roll-off at high frequency while enhancing the bandwidth. A complementary current-reuse technique is used between transconductance and IF stages to boost the conversion gain without additional power consumption by reusing the DC bias current of the LO stage. This downconversion double-balanced mixer exhibits a high and flat conversion gain (CG) of 14.9 ± 1.4 dB and a noise figure (NF) better than 12.8 dB. The maximum input 1-dB compression point (P1dB) and maximum input third-order intercept point (IIP3) are -13.6 dBm and -4.5 dBm, respectively, over the desired frequency ranging from 50 MHz to 10 GHz. The proposed circuit operates down to a supply headroom of 1 V with a low-power consumption of 3.5 mW.

  16. Coupling analysis of non-circular-symmetric modes and design of orientation-insensitive few-mode fiber couplers

    NASA Astrophysics Data System (ADS)

    Li, Jiaxiong; Du, Jiangbing; Ma, Lin; Li, Ming-Jun; Jiang, Shoulin; Xu, Xiao; He, Zuyuan

    2017-01-01

    We study the coupling between two identical weakly-coupled few-mode fibers based on coupled-mode theory. The coupling behavior of non-circular-symmetric modes, such as LP11 and LP21, is investigated analytically and numerically. By carefully choosing the fiber core separation and coupler length, we can design orientation-insensitive fiber couplers for non-circular-symmetric modes at arbitrary coupling ratios. Based on the design method, we propose an orientation-insensitive two-mode fiber coupler at 850 nm working as a mode multiplexer/demultiplexer for two-mode transmission using standard single-mode fiber. Within the band from 845 to 855 nm, the insertion losses of LP01 and LP11 modes are less than 0.03 dB and 0.24 dB, respectively. When the two-mode fiber coupler is used as mode demultiplexer, the LP01/LP11 and LP11/LP01 extinction ratios in the separated branches are respectively above 12.6 dB and 21.2 dB. Our design method can be extended to two-mode communication or sensing systems at other wavelengths.

  17. Audiogram of a striped dolphin (Stenella coeruleoalba)

    NASA Astrophysics Data System (ADS)

    Kastelein, Ronald A.; Hagedoorn, Monique; Au, Whitlow W. L.; de Haan, Dick

    2003-02-01

    The underwater hearing sensitivity of a striped dolphin was measured in a pool using standard psycho-acoustic techniques. The go/no-go response paradigm and up-down staircase psychometric method were used. Auditory sensitivity was measured by using 12 narrow-band frequency-modulated signals having center frequencies between 0.5 and 160 kHz. The 50% detection threshold was determined for each frequency. The resulting audiogram for this animal was U-shaped, with hearing capabilities from 0.5 to 160 kHz (8 13 oct). Maximum sensitivity (42 dB re 1 μPa) occurred at 64 kHz. The range of most sensitive hearing (defined as the frequency range with sensitivities within 10 dB of maximum sensitivity) was from 29 to 123 kHz (approximately 2 oct). The animal's hearing became less sensitive below 32 kHz and above 120 kHz. Sensitivity decreased by about 8 dB per octave below 1 kHz and fell sharply at a rate of about 390 dB per octave above 140 kHz.

  18. Do health care workforce, population, and service provision significantly contribute to the total health expenditure? An econometric analysis of Serbia.

    PubMed

    Santric-Milicevic, M; Vasic, V; Terzic-Supic, Z

    2016-08-15

    In times of austerity, the availability of econometric health knowledge assists policy-makers in understanding and balancing health expenditure with health care plans within fiscal constraints. The objective of this study is to explore whether the health workforce supply of the public health care sector, population number, and utilization of inpatient care significantly contribute to total health expenditure. The dependent variable is the total health expenditure (THE) in Serbia from the years 2003 to 2011. The independent variables are the number of health workers employed in the public health care sector, population number, and inpatient care discharges per 100 population. The statistical analyses include the quadratic interpolation method, natural logarithm and differentiation, and multiple linear regression analyses. The level of significance is set at P < 0.05. The regression model captures 90 % of all variations of observed dependent variables (adjusted R square), and the model is significant (P < 0.001). Total health expenditure increased by 1.21 standard deviations, with an increase in health workforce growth rate by 1 standard deviation. Furthermore, this rate decreased by 1.12 standard deviations, with an increase in (negative) population growth rate by 1 standard deviation. Finally, the growth rate increased by 0.38 standard deviation, with an increase of the growth rate of inpatient care discharges per 100 population by 1 standard deviation (P < 0.001). Study results demonstrate that the government has been making an effort to control strongly health budget growth. Exploring causality relationships between health expenditure and health workforce is important for countries that are trying to consolidate their public health finances and achieve universal health coverage at the same time.

  19. Real-time database drawn from an electronic health record for a thoracic surgery unit: high-quality clinical data saving time and human resources.

    PubMed

    Salati, Michele; Pompili, Cecilia; Refai, Majed; Xiumè, Francesco; Sabbatini, Armando; Brunelli, Alessandro

    2014-06-01

    The aim of the present study was to verify whether the implementation of an electronic health record (EHR) in our thoracic surgery unit allows creation of a high-quality clinical database saving time and costs. Before August 2011, multiple individuals compiled the on-paper documents/records and a single data manager inputted selected data into the database (traditional database, tDB). Since the adoption of an EHR in August 2011, multiple individuals have been responsible for compiling the EHR, which automatically generates a real-time database (EHR-based database, eDB), without the need for a data manager. During the initial period of implementation of the EHR, periodic meetings were held with all physicians involved in the use of the EHR in order to monitor and standardize the data registration process. Data quality of the first 100 anatomical lung resections recorded in the eDB was assessed by measuring the total number of missing values (MVs: existing non-reported value) and inaccurate values (wrong data) occurring in 95 core variables. The average MV of the eDB was compared with the one occurring in the same variables of the last 100 records registered in the tDB. A learning curve was constructed by plotting the number of MVs in the electronic database and tDB with the patients arranged by the date of registration. The tDB and eDB had similar MVs (0.74 vs 1, P = 0.13). The learning curve showed an initial phase including about 35 records, where MV in the eDB was higher than that in the tDB (1.9 vs 0.74, P = 0.03), and a subsequent phase, where the MV was similar in the two databases (0.7 vs 0.74, P = 0.6). The inaccuracy rate of these two phases in the eDB was stable (0.5 vs 0.3, P = 0.3). Using EHR saved an average of 9 min per patient, totalling 15 h saved for obtaining a dataset of 100 patients with respect to the tDB. The implementation of EHR allowed streamlining the process of clinical data recording. It saved time and human resource costs, without compromising the quality of data. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. The truly remarkable universality of half a standard deviation: confirmation through another look.

    PubMed

    Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W

    2004-10-01

    In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.

  1. Static Scene Statistical Non-Uniformity Correction

    DTIC Science & Technology

    2015-03-01

    Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion

  2. Effect of multizone refractive multifocal contact lenses on standard automated perimetry.

    PubMed

    Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa

    2012-09-01

    The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.

  3. Phenotypic Screening In Vitro of Novel Aromatic Amidines against Trypanosoma cruzi.

    PubMed

    Simões-Silva, M R; Nefertiti, A S G; De Araújo, J S; Batista, M M; Da Silva, P B; Bahia, M T; Menna-Barreto, R S; Pavão, B P; Green, J; Farahat, A A; Kumar, A; Boykin, D W; Soeiro, M N C

    2016-08-01

    The current treatment of Chagas disease (CD), based on nifurtimox and benznidazole (Bz), is unsatisfactory. In this context, we performed the phenotypic in vitro screening of novel mono- and diamidines and drug interaction assays with selected compounds. Ten novel amidines were tested for their activities against bloodstream trypomastigote (BT) and amastigote forms of Trypanosoma cruzi (Y and Tulahuen strains) and their toxicities for mammalian host cells (L929 cells and cardiac cells). Seven of 10 molecules were more active than Bz against BT, with the most active compound being the diamidine DB2267 (50% effective concentration [EC50] = 0.23 μM; selectivity index = 417), which was 28-fold more active and about 3 times more selective than the standard drug. Five of the six monoamidines were also more active than Bz. The combination of DB2267 and DB2236 in fixed-ratio proportions showed an additive effect (sum of fractional inhibitory concentrations < 4) on BT. Interestingly, when intracellular forms were exposed to DB2267, its activity was dependent on the parasite strain, being effective (EC50 = 0.87 ± 0.05 μM) against a discrete typing unit (DTU) II strain (strain Y) but not against a representative DTU VI strain (strain Tulahuen) even when different vehicles (β-cyclodextrin and dimethyl sulfoxide) were used. The intrinsic fluorescence of several diamidines allowed their uptake to be studied. Testing of the uptake of DB2236 (inactive) and DB2267 (active) by amastigotes of the Y strain showed that the two compounds were localized intracellularly in different compartments: DB2236 in the cytoplasm and DB2267 in the nucleus. Our present data encourage further studies regarding the activities of amidines and provide information which will help with the identification of novel agents for the treatment of CD. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Quality Improvement Initiative to Reduce Pediatric Intensive Care Unit Noise Pollution With the Use of a Pediatric Delirium Bundle.

    PubMed

    Kawai, Yu; Weatherhead, Jeffrey R; Traube, Chani; Owens, Tonie A; Shaw, Brenda E; Fraser, Erin J; Scott, Annette M; Wojczynski, Melody R; Slaman, Kristen L; Cassidy, Patty M; Baker, Laura A; Shellhaas, Renee A; Dahmer, Mary K; Shever, Leah L; Malas, Nasuh M; Niedner, Matthew F

    2017-01-01

    Noise pollution in pediatric intensive care units (PICU) contributes to poor sleep and may increase risk of developing delirium. The Environmental Protection Agency (EPA) recommends <45 decibels (dB) in hospital environments. The objectives are to assess the degree of PICU noise pollution, to develop a delirium bundle targeted at reducing noise, and to assess the effect of the bundle on nocturnal noise pollution. This is a QI initiative at an academic PICU. Thirty-five sound sensors were installed in patient bed spaces, hallways, and common areas. The pediatric delirium bundle was implemented in 8 pilot patients (40 patient ICU days) while 108 non-pilot patients received usual care over a 28-day period. A total of 20,609 hourly dB readings were collected. Hourly minimum, average, and maximum dB of all occupied bed spaces demonstrated medians [interquartile range] of 48.0 [39.0-53.0], 52.8 [48.1-56.2] and 67.0 [63.5-70.5] dB, respectively. Bed spaces were louder during the day (10AM to 4PM) than at night (11PM to 5AM) (53.5 [49.0-56.8] vs. 51.3 [46.0-55.3] dB, P < 0.01). Pilot patient rooms were significantly quieter than non-pilot patient rooms at night (n=210, 45.3 [39.7-55.9]) vs. n=1841, 51.2 [46.9-54.8] dB, P < 0.01). The pilot rooms compliant with the bundle had the lowest hourly nighttime average dB (44.1 [38.5-55.5]). Substantial noise pollution exists in our PICU, and utilizing the pediatric delirium bundle led to a significant noise reduction that can be perceived as half the loudness with hourly nighttime average dB meeting the EPA standards when compliant with the bundle.

  5. Deep Defects Seen on Visual Fields Spatially Correspond Well to Loss of Retinal Nerve Fiber Layer Seen on Circumpapillary OCT Scans.

    PubMed

    Mavrommatis, Maria A; Wu, Zhichao; Naegele, Saskia I; Nunez, Jason; De Moraes, Carlos; Ritch, Robert; Hood, Donald C

    2018-02-01

    To examine the structure-function relationship in glaucoma between deep defects on visual fields (VF) and deep losses in the circumpapillary retinal nerve fiber layer (cpRNFL) on optical coherence tomography (OCT) circle scans. Thirty two glaucomatous eyes with deep VF defects, as defined by at least one test location worse than ≤ -15 dB on the 10-2 and/or 24-2 VF pattern deviation (PD) plots, were included from 87 eyes with "early" glaucoma (i.e., 24-2 mean deviation better than -6 dB). Using the location of the deep VF points and a schematic model, the location of local damage on an OCT circle scan was predicted. The thinnest location of cpRNFL (i.e., deepest loss) was also determined. In 19 of 32 eyes, a region of complete or near complete cpRNFL loss was observed. All 19 of these had deep VF defects on the 24-2 and/or 10-2. All of the 32 eyes with deep VF defects had abnormal cpRNFL regions (red, 1%) and all but 2 had a region of cpRNFL thickness <21 μm. The midpoint of the VF defect and the location of deepest cpRNFL had a 95% limit of agreement within approximately two-thirds of a clock-hour (or 30°) sector (between -22.1° to 25.2°). Individual fovea-to-disc angle (FtoDa) adjustment improved agreement in one eye with an extreme FtoDa. Although studies relating local structural (OCT) and functional (VF) measures typically show poor to moderate correlations, there is good qualitative agreement between the location of deep cpRNFL loss and deep defects on VFs.

  6. Baseline 24-2 Central Visual Field Damage Is Predictive of Global Progressive Field Loss.

    PubMed

    Garg, Aakriti; De Moraes, C Gustavo; Cioffi, George A; Girkin, Christopher A; Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M; Liebmann, Jeffrey M

    2018-03-01

    Central visual field (VF) damage in glaucoma patients can significantly hinder daily activities. The present study investigates whether the presence of localized baseline damage to the central 10 degrees of the VF is predictive of faster global mean deviation (MD) progression. Prospective cohort study. Eyes from the multicenter African Descent and Glaucoma Evaluation Study (ADAGES) with established glaucoma and VF loss and a minimum of 5 24-2 VFs were eligible. Baseline central 24-2 damage was defined as any of the 12 central-most points with total deviation (TD) values at P < 0.5% on 2 consecutive examinations. Progression was determined using trend-based and event-based criteria: (1) rates of MD change significantly faster than zero and (2) >-5 dB MD loss over the entire follow-up. A total of 827 eyes of 584 patients were studied. Mean rate of MD change of the entire sample was -0.15 dB/year (95% CI: -0.19 to -0.12, P < .001). Eyes with baseline central damage progressed faster than those without (difference: β central  = -0.07 dB/year, 95% CI: -0.11 to -0.01, P = .011) and were more likely to experience MD loss greater than 5 dB (hazard ratio = 3.0 [95% CI: 2.1-4.1, P < .001]). These differences remained significant after adjusting for confounders. The presence of central VF damage at baseline is significantly associated with more rapid global progression. Detection of central VF damage aids in stratification of high-risk patients who may need intensive surveillance and aggressive treatment. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. New methods of multimode fiber interferometer signal processing

    NASA Astrophysics Data System (ADS)

    Vitrik, Oleg B.; Kulchin, Yuri N.; Maxaev, Oleg G.; Kirichenko, Oleg V.; Kamenev, Oleg T.; Petrov, Yuri S.

    1995-06-01

    New methods of multimode fiber interferometers signal processing are suggested. For scheme of single fiber multimode interferometers with two excited modes, the method based on using of special fiber unit is developed. This unit provides the modes interaction and further sum optical field filtering. As a result the amplitude of output signal is modulated by external influence on interferometer. The stabilization of interferometer sensitivity is achieved by using additional special modulation of output signal. For scheme of single fiber multimode interferometers with excitation of wide mode spectrum, the signal of intermode interference is registered by photodiode matrix and then special electronic unit performs correlation processing. For elimination of temperature destabilization, the registered signal is adopted to multimode interferometers optical signal temperature changes. The achieved parameters for double mode scheme: temporary stability--0.6% per hour, sensitivity to interferometer length deviations--3,2 nm; for multimode scheme: temperature stability--(0.5%)/(K), temporary nonstability--0.2% per hour, sensitivity to interferometer length deviations--20 nm, dynamic range--35 dB.

  8. Assessment and analysis of noise pollution in Biskra public gardens (Algeria)

    NASA Astrophysics Data System (ADS)

    Bouzir, Tallal Abdel Karim; Zemmouri, Noureddine; Berkouk, Djihed

    2018-05-01

    A quantitative evaluation of noise pollution in the public gardens of Biskra, Algeria, was carried out in this research. The equivalent sound level (leq1min) was measured in 27 points distributed over the seven main gardens of the city. The results of the measurements show that the measured level of sound intensity varies from 56.38 dB in the Landon garden to 62.55 dB in the Larbi Ben Mhidi garden. By comparing, the measured values with the noise limit values recommended by the national legislation, the standards of the World Health Organization and the United States Environmental Protection Agency; it is clear that the sound environment in these public gardens do not comply with the recognized standards of acoustic comfort. The gardens' spaces are heavily over-exposed to traffic noise resulting in high levels acoustic pollution.

  9. Investigation of the refractive index repeatability for tantalum pentoxide coatings, prepared by physical vapor film deposition techniques.

    PubMed

    Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J

    2017-02-01

    Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.

  10. Closed-form confidence intervals for functions of the normal mean and standard deviation.

    PubMed

    Donner, Allan; Zou, G Y

    2012-08-01

    Confidence interval methods for a normal mean and standard deviation are well known and simple to apply. However, the same cannot be said for important functions of these parameters. These functions include the normal distribution percentiles, the Bland-Altman limits of agreement, the coefficient of variation and Cohen's effect size. We present a simple approach to this problem by using variance estimates recovered from confidence limits computed for the mean and standard deviation separately. All resulting confidence intervals have closed forms. Simulation results demonstrate that this approach performs very well for limits of agreement, coefficients of variation and their differences.

  11. Sample sizes needed for specified margins of relative error in the estimates of the repeatability and reproducibility standard deviations.

    PubMed

    McClure, Foster D; Lee, Jung K

    2005-01-01

    Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.

  12. An index of refraction algorithm for seawater over temperature, pressure, salinity, density, and wavelength

    NASA Astrophysics Data System (ADS)

    Millard, R. C.; Seaver, G.

    1990-12-01

    A 27-term index of refraction algorithm for pure and sea waters has been developed using four experimental data sets of differing accuracies. They cover the range 500-700 nm in wavelength, 0-30°C in temperature, 0-40 psu in salinity, and 0-11,000 db in pressure. The index of refraction algorithm has an accuracy that varies from 0.4 ppm for pure water at atmospheric pressure to 80 ppm at high pressures, but preserves the accuracy of each original data set. This algorithm is a significant improvement over existing descriptions as it is in analytical form with a better and more carefully defined accuracy. A salinometer algorithm with the same uncertainty has been created by numerically inverting the index algorithm using the Newton-Raphson method. The 27-term index algorithm was used to generate a pseudo-data set at the sodium D wavelength (589.26 nm) from which a 6-term densitometer algorithm was constructed. The densitometer algorithm also produces salinity as an intermediate step in the salinity inversion. The densitometer residuals have a standard deviation of 0.049 kg m -3 which is not accurate enough for most oceanographic applications. However, the densitometer algorithm was used to explore the sensitivity of density from this technique to temperature and pressure uncertainties. To achieve a deep ocean densitometer of 0.001 kg m -3 accuracy would require the index of refraction to have an accuracy of 0.3 ppm, the temperature an accuracy of 0.01°C and the pressure 1 db. Our assessment of the currently available index of refraction measurements finds that only the data for fresh water at atmospheric pressure produce an algorithm satisfactory for oceanographic use (density to 0.4 ppm). The data base for the algorithm at higher pressures and various salinities requires an order of magnitude or better improvement in index measurement accuracy before the resultant density accuracy will be comparable to the currently available oceanographic algorithm.

  13. The development and validation of the Closed-set Mandarin Sentence (CMS) test.

    PubMed

    Tao, Duo-Duo; Fu, Qian-Jie; Galvin, John J; Yu, Ya-Feng

    2017-09-01

    Matrix-styled sentence tests offer a closed-set paradigm that may be useful when evaluating speech intelligibility. Ideally, sentence test materials should reflect the distribution of phonemes within the target language. We developed and validated the Closed-set Mandarin Sentence (CMS) test to assess Mandarin speech intelligibility in noise. CMS test materials were selected to be familiar words and to represent the natural distribution of vowels, consonants, and lexical tones found in Mandarin Chinese. Ten key words in each of five categories (Name, Verb, Number, Color, and Fruit) were produced by a native Mandarin talker, resulting in a total of 50 words that could be combined to produce 100,000 unique sentences. Normative data were collected in 10 normal-hearing, adult Mandarin-speaking Chinese listeners using a closed-set test paradigm. Two test runs were conducted for each subject, and 20 sentences per run were randomly generated while ensuring that each word was presented only twice in each run. First, the level of the words in each category were adjusted to produce equal intelligibility in noise. Test-retest reliability for word-in-sentence recognition was excellent according to Cronbach's alpha (0.952). After the category level adjustments, speech reception thresholds (SRTs) for sentences in noise, defined as the signal-to-noise ratio (SNR) that produced 50% correct whole sentence recognition, were adaptively measured by adjusting the SNR according to the correctness of response. The mean SRT was -7.9 (SE=0.41) and -8.1 (SE=0.34) dB for runs 1 and 2, respectively. The mean standard deviation across runs was 0.93 dB, and paired t-tests showed no significant difference between runs 1 and 2 (p=0.74) despite random sentences being generated for each run and each subject. The results suggest that the CMS provides large stimulus set with which to repeatedly and reliably measure Mandarin-speaking listeners' speech understanding in noise using a closed-set paradigm.

  14. Field-scale surface soil moisture retrieval using L-band synthetic aperture radar data: shrublands examples

    NASA Astrophysics Data System (ADS)

    Kim, S.; Arii, M.; Jackson, T. J.

    2017-12-01

    L-band airborne synthetic aperture radar (SAR) observations at 7-m spatial resolution were made over California shrublands to better understand the effects of soil and vegetation parameters on backscattering coefficient (σ0). Temporal changes in σ0 of up to 3 dB were highly correlated to surface soil moisture but not to vegetation, even though vegetation water content (VWC) varied seasonally by a factor of two. HH was always greater than VV, suggesting the importance of double-bounce scattering by the woody parts. However, the geometric and dielectric properties of the woody parts did not vary significantly over time. Instead the changes in VWC occurred primarily in thin leaves that may not meaningfully influence absorption and scattering. A physically-based model for single scattering by discrete elements of plants successfully simulated the magnitude of the temporal variations in HH, VV, and HH/VV with a difference of less than 0.9 dB. In order to simulate the observations, the VWC input of the plant to the model was formulated as a function of plant's dielectric property (water fraction) while the plant geometry remains static in time. In comparison, when the VWC input was characterized by the geometry of a growing plant, the model performed poorly in describing the observed patterns in the σ0 changes. The modeling results offer explanation of the observation that soil moisture correlated highly with σ0: the dominant mechanisms for HH and VV are double-bounce scattering by trunk, and soil surface scattering, respectively. The time-series inversion of the physical model was able to retrieve soil moisture with the difference of -0.037 m3/m3 (mean), 0.025 m3/m3 (standard deviation), and 0.89 (correlation). Together with the previous results over croplands using the SAR data offering 0.05 m3/m3 retrieval accuracy, we will demonstrate the efficacy of the model-based time-series soil moisture retrieval at field scales.

  15. Comparing biomarker measurements to a normal range: when to use standard error of the mean (SEM) or standard deviation (SD) confidence intervals tests.

    PubMed

    Pleil, Joachim D

    2016-01-01

    This commentary is the second of a series outlining one specific concept in interpreting biomarkers data. In the first, an observational method was presented for assessing the distribution of measurements before making parametric calculations. Here, the discussion revolves around the next step, the choice of using standard error of the mean or the calculated standard deviation to compare or predict measurement results.

  16. Statistical study of the reliability of oxide-defined stripe cw lasers of (AlGa)As

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ettenberg, M.

    1979-03-01

    In this report, we describe a statistical study of the reliability of oxide-defined stripe-contact cw injection lasers of (AlGa)As. These devices have one facet coated with Al/sub 2/O/sub 3/ and one facet coated with an Al/sub 2/O/sub 3//Si dichroic reflector; the lasers are optimized for cw low-threshold currents at room temperature, with values typically about 50 mA. Lifetests were carried out at 70 /sup 0/C ambient, in the cw mode of operation with about 5 mW output. Previous lifetests showed that the degradation rate followed a 0.95-eV activation energy so the 70 /sup 0/C environment provides a degradation acceleration factormore » of 190 over that at room temperature. We have found that the device failures follow a log-normal distribution, characterized by a mean time before failure of 4200 h and a standard deviation of 1.3. This corresponds to a mean time to failure (MTTF) of 10/sup 6/ h at room temperature. Failure is defined here as the inability of the device to emit 1 mW of stimulated cw output at 70 /sup 0/C, and assumes that optical feedback will be employed to adjust the laser current during operation. If a constant-current drive is envisioned, the failures for a 3-dB drop in light output also follow a log-normal distribution with a similar slope (standard deviation=1.1) and a MTTF of 2000 h at 70 /sup 0/C (500 000 h at room temperature). The failures were found to be mainly due to bulk gradual degradation and not facet or contact failure. Careful study of lasers before and after lifetest showed a significant increase in contact thermal resistance. However, this increase accounts for only a small portion of the nearly 70% increase in room-temperature cw threshold after failure at 70 /sup 0/C. After failure at 70 /sup 0/C, we also noted a degradation in the near-field and associated far-field pattern of the laser.« less

  17. Systemic Review of Anatomic Single- Versus Double-Bundle Anterior Cruciate Ligament Reconstruction: Does Femoral Tunnel Drilling Technique Matter?

    PubMed

    Zhang, Yang; Xu, Caiqi; Dong, Shiqui; Shen, Peng; Su, Wei; Zhao, Jinzhong

    2016-09-01

    To provide an up-to-date assessment of the difference between anatomic double-bundle anterior cruciate ligament (ACL) reconstruction (DB-ACLR) and anatomic single-bundle ACL reconstruction (SB-ACLR). We hypothesized that anatomic SB-ACLR using independent femoral drilling technique would be able to achieve kinematic stability as with anatomic DB-ACLR. A comprehensive Internet search was performed to identify all therapeutic trials of anatomic DB-ACLR versus anatomic SB-ACLR. Only clinical studies of Level I and II evidence were included. The comparative outcomes were instrument-measured anterior laxity, Lachman test, pivot shift, clinical outcomes including objective/subjective International Knee Documentation Committee (IKDC) score, Lysholm score, Tegner activity scale and complication rates of extension/flexion deficits, graft failure, and early osteoarthritis. Subgroup analyses were performed for femoral tunnel drilling techniques including independent drilling and transtibial (TT) drilling. Twenty-two clinical trials of 2,261 anatomically ACL-reconstructed patients were included in the meta-analysis. Via TT drilling technique, anatomic DB-ACLR led to improved instrument-measured anterior laxity with a standard mean difference (SMD) of -0.42 (95% confidence interval [CI] = -0.81 to -0.02), less rotational instability measured by pivot shift (SMD = 2.76, 95% CI = 1.24 to 6.16), and higher objective IKDC score with odds ratio (OR) of 2.28 (95% CI = 1.19 to 4.36). Via independent drilling technique, anatomic DB-ACLR yielded better pivot shift (SMD = 2.04, 95% CI = 1.36 to 3.05). Anatomic DB-ACLR also revealed statistical significance in subjective IKDC score compared with anatomic SB-ACLR (SMD = 0.27, 95% CI = 0.05 to 0.49). Anatomic DB-ACLR showed better anterior and rotational stability and higher objective IKDC score than anatomic SB-ACLR via TT drilling technique. Via independent drilling technique, however, anatomic DB-ACLR only showed superiority of rotational stability. All clinical function outcomes except subjective IKDC score were not significantly different between anatomic DB-ACLR and SB-ACLR. Level II, meta-analysis of Level I and II studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  19. Executing Complexity-Increasing Queries in Relational (MySQL) and NoSQL (MongoDB and EXist) Size-Growing ISO/EN 13606 Standardized EHR Databases

    PubMed Central

    Sánchez-de-Madariaga, Ricardo; Muñoz, Adolfo; Castro, Antonio L; Moreno, Oscar; Pascual, Mario

    2018-01-01

    This research shows a protocol to assess the computational complexity of querying relational and non-relational (NoSQL (not only Structured Query Language)) standardized electronic health record (EHR) medical information database systems (DBMS). It uses a set of three doubling-sized databases, i.e. databases storing 5000, 10,000 and 20,000 realistic standardized EHR extracts, in three different database management systems (DBMS): relational MySQL object-relational mapping (ORM), document-based NoSQL MongoDB, and native extensible markup language (XML) NoSQL eXist. The average response times to six complexity-increasing queries were computed, and the results showed a linear behavior in the NoSQL cases. In the NoSQL field, MongoDB presents a much flatter linear slope than eXist. NoSQL systems may also be more appropriate to maintain standardized medical information systems due to the special nature of the updating policies of medical information, which should not affect the consistency and efficiency of the data stored in NoSQL databases. One limitation of this protocol is the lack of direct results of improved relational systems such as archetype relational mapping (ARM) with the same data. However, the interpolation of doubling-size database results to those presented in the literature and other published results suggests that NoSQL systems might be more appropriate in many specific scenarios and problems to be solved. For example, NoSQL may be appropriate for document-based tasks such as EHR extracts used in clinical practice, or edition and visualization, or situations where the aim is not only to query medical information, but also to restore the EHR in exactly its original form. PMID:29608174

  20. Executing Complexity-Increasing Queries in Relational (MySQL) and NoSQL (MongoDB and EXist) Size-Growing ISO/EN 13606 Standardized EHR Databases.

    PubMed

    Sánchez-de-Madariaga, Ricardo; Muñoz, Adolfo; Castro, Antonio L; Moreno, Oscar; Pascual, Mario

    2018-03-19

    This research shows a protocol to assess the computational complexity of querying relational and non-relational (NoSQL (not only Structured Query Language)) standardized electronic health record (EHR) medical information database systems (DBMS). It uses a set of three doubling-sized databases, i.e. databases storing 5000, 10,000 and 20,000 realistic standardized EHR extracts, in three different database management systems (DBMS): relational MySQL object-relational mapping (ORM), document-based NoSQL MongoDB, and native extensible markup language (XML) NoSQL eXist. The average response times to six complexity-increasing queries were computed, and the results showed a linear behavior in the NoSQL cases. In the NoSQL field, MongoDB presents a much flatter linear slope than eXist. NoSQL systems may also be more appropriate to maintain standardized medical information systems due to the special nature of the updating policies of medical information, which should not affect the consistency and efficiency of the data stored in NoSQL databases. One limitation of this protocol is the lack of direct results of improved relational systems such as archetype relational mapping (ARM) with the same data. However, the interpolation of doubling-size database results to those presented in the literature and other published results suggests that NoSQL systems might be more appropriate in many specific scenarios and problems to be solved. For example, NoSQL may be appropriate for document-based tasks such as EHR extracts used in clinical practice, or edition and visualization, or situations where the aim is not only to query medical information, but also to restore the EHR in exactly its original form.

  1. Odds per Adjusted Standard Deviation: Comparing Strengths of Associations for Risk Factors Measured on Different Scales and Across Diseases and Populations

    PubMed Central

    Hopper, John L.

    2015-01-01

    How can the “strengths” of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors—and that is how risk gradients are interpreted—so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RRs. This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. PMID:26520360

  2. Selection of vegetation indices for mapping the sugarcane condition around the oil and gas field of North West Java Basin, Indonesia

    NASA Astrophysics Data System (ADS)

    Muji Susantoro, Tri; Wikantika, Ketut; Saepuloh, Asep; Handoyo Harsolumakso, Agus

    2018-05-01

    Selection of vegetation indices in plant mapping is needed to provide the best information of plant conditions. The methods used in this research are the standard deviation and the linear regression. This research tried to determine the vegetation indices used for mapping the sugarcane conditions around oil and gas fields. The data used in this study is Landsat 8 OLI/TIRS. The standard deviation analysis on the 23 vegetation indices with 27 samples has resulted in the six highest standard deviations of vegetation indices, termed as GRVI, SR, NLI, SIPI, GEMI and LAI. The standard deviation values are 0.47; 0.43; 0.30; 0.17; 0.16 and 0.13. Regression correlation analysis on the 23 vegetation indices with 280 samples has resulted in the six vegetation indices, termed as NDVI, ENDVI, GDVI, VARI, LAI and SIPI. This was performed based on regression correlation with the lowest value R2 than 0,8. The combined analysis of the standard deviation and the regression correlation has obtained the five vegetation indices, termed as NDVI, ENDVI, GDVI, LAI and SIPI. The results of the analysis of both methods show that a combination of two methods needs to be done to produce a good analysis of sugarcane conditions. It has been clarified through field surveys and showed good results for the prediction of microseepages.

  3. Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lye, Jessica, E-mail: jessica.lye@arpansa.gov.au; Dunn, Leon; Kenny, John

    Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectorsmore » are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3.9% (3σ) for the new OSLD audit. Previously with the TLD audit the Pass (Optimal Level) and Fail (Out of Tolerance) were set at ≤4.0% (2σ) and >6.0% (3σ). Conclusions: The calculated standard uncertainty of 1.3% at one standard deviation is consistent with the measured standard deviation of 1.4% from the audits and confirming the suitability of the uncertainty budget derived audit tolerances. The OSLD audit shows greater accuracy than the previous TLD audit, justifying the reduction in audit tolerances. In the TLD audit, all outcomes were Pass (Optimal Level) suggesting that the tolerances were too conservative. In the OSLD audit 94% of the audits have resulted in Pass (Optimal level) and 6% of the audits have resulted in Pass (Action Level). All Pass (Action level) results have been resolved with a repeat OSLD audit, or an on-site ion chamber measurement.« less

  4. Collinearity in Least-Squares Analysis

    ERIC Educational Resources Information Center

    de Levie, Robert

    2012-01-01

    How useful are the standard deviations per se, and how reliable are results derived from several least-squares coefficients and their associated standard deviations? When the output parameters obtained from a least-squares analysis are mutually independent, as is often assumed, they are reliable estimators of imprecision and so are the functions…

  5. Robust Confidence Interval for a Ratio of Standard Deviations

    ERIC Educational Resources Information Center

    Bonett, Douglas G.

    2006-01-01

    Comparing variability of test scores across alternate forms, test conditions, or subpopulations is a fundamental problem in psychometrics. A confidence interval for a ratio of standard deviations is proposed that performs as well as the classic method with normal distributions and performs dramatically better with nonnormal distributions. A simple…

  6. Standard Deviation for Small Samples

    ERIC Educational Resources Information Center

    Joarder, Anwar H.; Latif, Raja M.

    2006-01-01

    Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…

  7. Estimating maize water stress by standard deviation of canopy temperature in thermal imagery

    USDA-ARS?s Scientific Manuscript database

    A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...

  8. Classification of Chemicals Based On Structured Toxicity ...

    EPA Pesticide Factsheets

    Thirty years and millions of dollars worth of pesticide registration toxicity studies, historically stored as hardcopy and scanned documents, have been digitized into highly standardized and structured toxicity data within the Toxicity Reference Database (ToxRefDB). Toxicity-based classifications of chemicals were performed as a model application of ToxRefDB. These endpoints will ultimately provide the anchoring toxicity information for the development of predictive models and biological signatures utilizing in vitro assay data. Utilizing query and structured data mining approaches, toxicity profiles were uniformly generated for greater than 300 chemicals. Based on observation rate, species concordance and regulatory relevance, individual and aggregated effects have been selected to classify the chemicals providing a set of predictable endpoints. ToxRefDB exhibits the utility of transforming unstructured toxicity data into structured data and, furthermore, into computable outputs, and serves as a model for applying such data to address modern toxicological problems.

  9. Off-nadir antenna bias correction using Amazon rain sigma(0) data

    NASA Technical Reports Server (NTRS)

    Birrer, I. J.; Dome, G. J.; Sweet, J.; Berthold, G.; Moore, R. K.

    1982-01-01

    The radar response from the Amazon rain forest was studied to determine the suitability of this region for use as a standard target to calibrate a scatterometer like that proposed for the National Oceanic Satellite System (NOSS). Backscattering observations made by the SEASAT Scatterometer System (SASS) showed the Amazon rain forest to be a homogeneous, azimuthally-isotropic, radar target which was insensitive to polarization. The variation with angle of incidence was adequately modeled as scattering coefficient (dB) = a theta b with typical values for the incidence-angle coefficient from 0.07 to 0.15 dB/deg. A small diurnal effect occurs, with measurements at sunrise being 0.5 dB to 1 dB higher than the rest of the day. Maximum-likelihood estimation algorithms presented here permit determination of relative bias and true pointing angle for each beam. Specific implementation of these algorithms for the proposed NOSS scatterometer system is also discussed.

  10. Implementation of the CMOS MEMS Condenser Microphone with Corrugated Metal Diaphragm and Silicon Back-Plate

    PubMed Central

    Huang, Chien-Hsin; Lee, Chien-Hsing; Hsieh, Tsung-Min; Tsao, Li-Chi; Wu, Shaoyi; Liou, Jhyy-Cheng; Wang, Ming-Yi; Chen, Li-Che; Yip, Ming-Chuen; Fang, Weileun

    2011-01-01

    This study reports a CMOS-MEMS condenser microphone implemented using the standard thin film stacking of 0.35 μm UMC CMOS 3.3/5.0 V logic process, and followed by post-CMOS micromachining steps without introducing any special materials. The corrugated diaphragm for the microphone is designed and implemented using the metal layer to reduce the influence of thin film residual stresses. Moreover, a silicon substrate is employed to increase the stiffness of the back-plate. Measurements show the sensitivity of microphone is −42 ± 3 dBV/Pa at 1 kHz (the reference sound-level is 94 dB) under 6 V pumping voltage, the frequency response is 100 Hz–10 kHz, and the S/N ratio >55 dB. It also has low power consumption of less than 200 μA, and low distortion of less than 1% (referred to 100 dB). PMID:22163953

  11. Experiments with central-limit properties of spatial samples from locally covariant random fields

    USGS Publications Warehouse

    Barringer, T.H.; Smith, T.E.

    1992-01-01

    When spatial samples are statistically dependent, the classical estimator of sample-mean standard deviation is well known to be inconsistent. For locally dependent samples, however, consistent estimators of sample-mean standard deviation can be constructed. The present paper investigates the sampling properties of one such estimator, designated as the tau estimator of sample-mean standard deviation. In particular, the asymptotic normality properties of standardized sample means based on tau estimators are studied in terms of computer experiments with simulated sample-mean distributions. The effects of both sample size and dependency levels among samples are examined for various value of tau (denoting the size of the spatial kernel for the estimator). The results suggest that even for small degrees of spatial dependency, the tau estimator exhibits significantly stronger normality properties than does the classical estimator of standardized sample means. ?? 1992.

  12. High-contrast grating hollow-core waveguide splitter applied to optical phased array

    NASA Astrophysics Data System (ADS)

    Zhao, Che; Xue, Ping; Zhang, Hanxing; Chen, Te; Peng, Chao; Hu, Weiwei

    2014-11-01

    A novel hollow-core (HW) Y-branch waveguide splitter based on high-contrast grating (HCG) is presented. We calculated and designed the HCG-HW splitter using Rigorous Coupled Wave Analysis (RCWA). Finite-different timedomain (FDTD) simulation shows that the splitter has a broad bandwidth and the branching loss is as low as 0.23 dB. Fabrication is accomplished with standard Silicon-On-Insulator (SOI) process. The experimental measurement results indicate its good performance on beam splitting near the central wavelength λ = 1550 nm with a total insertion loss of 7.0 dB.

  13. Fusion splice between tapered inhibited coupling hypocycloid-core Kagome fiber and SMF.

    PubMed

    Zheng, Ximeng; Debord, Benoît; Vincetti, Luca; Beaudou, Benoît; Gérôme, Frédéric; Benabid, Fetah

    2016-06-27

    We report for the first time on tapering inhibited coupling (IC) hypocycloid-core shape Kagome hollow-core photonic crystal fibers whilst maintaining their delicate core-contour negative curvature with a down-ratio as large as 2.4. The transmission loss of down-tapered sections reaches a figure as low as 0.07 dB at 1550 nm. The tapered IC fibers are also spliced to standard SMF with a total insertion loss of 0.48 dB. These results show that all-fiber photonic microcells with the ultra-low loss hypocycloid core-contour Kagome fibers is now possible.

  14. Fiber-optic coupling based on nonimaging expanded-beam optics.

    PubMed

    Moslehi, B; Ng, J; Kasimoff, I; Jannson, T

    1989-12-01

    We have fabricated and experimentally tested low-cost and mass-producible multimode fiber-optic couplers and connectors based on nonimaging beam-expanding optics and Liouville's theorem. Analysis indicates that a pair coupling loss of -0.25 dB can be achieved. Experimentally, we measured insertion losses as low as -0.38 dB. The beam expanders can be mass produced owing to the use of plastic injection-molding fabrication techniques and packaged in standard connector housings. This design is compatible with the fiber geometry and can yield highly stable coupling owing to its high tolerance for misalignments.

  15. YALE NATURAL RADIOCARBON MEASUREMENTS. PART VI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuiver, M.; Deevey, E.S.

    1961-01-01

    Most of the measurements made since publication of Yale V are included; some measurements, such as a series collected in Greenland, are withneld pending additional information or field work that will make better interpretations possible. In addition to radiocarbon dates of geologic and/or archaeologic interest, recent assays are given of C/sup 14/ in lake waters and other lacustrine materials, now normalized for C/sup 13/ content. The newly accepted convention is followed in expressing normalized C/sup 14/ values as DELTA = delta C/sup 14/ (2 delta C/sup 13/ + 50)STAl + ( delta C/sup 14//1000)! where DELTA is the per milmore » deviation of the C/sup 14/ if the sample from any contemporary standard (whether organic or a carbonate) after correction of sample and/or standard for real age, for the Suess effect, for normal isotopic fractionation, and for deviations of C/sup 14/ content of the age- and pollution- corrected l9th-century wood standard from that of 95% of the NBS oxalic acid standard; delta C/sup 14/ is the measured deviation from 95% of the NBS standard, and delta C/sup 13/ is the deviation from the NBS limestone standard, both in per mil. These assays are variously affected by artificial C/sup 14/ resulting from nuclear tests. (auth)« less

  16. Roles of an anti-tuberculosis medication and surgery in patients with tuberculous otitis media.

    PubMed

    Kwon, Minsu; Choi, Seung Hyo; Chung, Jong Woo

    2010-06-01

    The standard treatment for tuberculous otitis media (TOM) without complications consists of anti-tuberculosis (anti-TB) medication, with which we experienced good treatment outcomes. However, surgery is required for recovery of anatomy and hearing function. To determine the clinical characteristics of TOM that might optimize diagnosis and to evaluate the differences in clinical courses between patients treated with and without surgery. We analyzed 14 patients (16 ears) who had been diagnosed and treated for TOM. Radiologic findings, laboratory data, and audiometry results were also evaluated. Patients were divided into a chemotherapy group and a surgery group according to treatment modality. Temporal bone CT (TBCT) showed total occupation of the tympanic cavity by soft tissue and little evidence of ossicular erosion. In the chemotherapy group, dry ears were obtained in all but one patient (14 ears) after treatment. Normalized tympanic membrane (TM) was found in 50% in the chemotherapy group and in 75% in the surgery group. The air-bone gap (ABG) changed from 40.3 +/- 2.5 dB to 47.0 +/- 19.2 dB in the chemotherapy group and from 35.2 +/- 7.6 dB to 30.2 +/- 11.4 dB in the surgery group. After treatment, ABG improved by > 10 dB in one ear in the chemotherapy group and in four ears in the surgery group.

  17. Smart absorbing property of composites with MWCNTs and carbonyl iron as the filler

    NASA Astrophysics Data System (ADS)

    Xu, Yonggang; Yuan, Liming; Cai, Jun; Zhang, Deyuan

    2013-10-01

    A smart absorbing composite was prepared by mixing silicone rubber, multi-walled carbon nanotubes (MWCNTs) and flaky carbonyl iron particles (CIPs) in a two-roll mixer. The complex permittivity and permeability of composites with variable compression strain was measured by the transmission method and dc electric conductivity was measured by the standard four-point contact method, then the reflection loss (RL) could be calculated to evaluate the microwave absorbing ability. The results showed that the applied compression strain made the complex permittivity decrease but not obviously due to the broken original conductive network. The enforcement of the strain on the complex permeability was attributed to the orientation of flaky CIPs. With the compressing strain applied on the composites with thickness 1 mm or 1.5 mm, the RL value decreased (minimum -13.2 dB and -25.1 dB) and the absorbing band (RL<-10 dB) was widened (5.2-10.6 GHz and 4.0-8.4 GHz). While as the composite thickness decreased caused by the compression strain, the RL value still decreased (minimum -12.4 dB and -18.6 dB) and the absorbing band was also broadened (6.5-10.7 GHz and 4.4-10.0 GHz). Thus the smart absorbing property was effective on preparing absorbers with wide absorption band and high absorption ratio.

  18. Normative behavioral thresholds for short tone-bursts.

    PubMed

    Beattie, R C; Rochverger, I

    2001-10-01

    Although tone-bursts have been commonly used in auditory brainstem response (ABR) evaluations for many years, national standards describing normal calibration values have not been established. This study was designed to gather normative threshold data to establish a physical reference for tone-burst stimuli that can be reproduced across clinics and laboratories. More specifically, we obtained norms for 3-msec tone-bursts presented at two repetition rates (9.3/sec and 39/sec), two gating functions (Trapezoid and Blackman), and four frequencies (500, 1000, 2000, and 4000 Hz). Our results are specified using three physical references: dB peak sound pressure level, dB peak-to-peak equivalent sound pressure level, and dB SPL (fast meter response, rate = 50 stimuli/sec). These data are offered for consideration when calibrating ABR equipment. The 39/sec stimulus rate yielded tone-burst thresholds that were approximately 3 dB lower than the 9.3/sec rate. The improvement in threshold with increasing stimulus rate may reflect the ability of the auditory system to integrate energy that occurs within a time interval of 200 to 500 msec (temporal integration). The Trapezoid gating function yielded thresholds that averaged 1.4 dB lower than the Blackman function. Although these differences are small and of little clinical importance, the cumulative effects of several instrument and/or procedural variables may yield clinically important differences.

  19. Measuring hearing in the harbor seal (Phoca vitulina): Comparison of behavioral and auditory brainstem response techniques

    NASA Astrophysics Data System (ADS)

    Wolski, Lawrence F.; Anderson, Rindy C.; Bowles, Ann E.; Yochem, Pamela K.

    2003-01-01

    Auditory brainstem response (ABR) and standard behavioral methods were compared by measuring in-air audiograms for an adult female harbor seal (Phoca vitulina). Behavioral audiograms were obtained using two techniques: the method of constant stimuli and the staircase method. Sensitivity was tested from 0.250 to 30 kHz. The seal showed good sensitivity from 6 to 12 kHz [best sensitivity 8.1 dB (re 20 μPa2.s) RMS at 8 kHz]. The staircase method yielded thresholds that were lower by 10 dB on average than the method of constant stimuli. ABRs were recorded at 2, 4, 8, 16, and 22 kHz and showed a similar best range (8-16 kHz). ABR thresholds averaged 5.7 dB higher than behavioral thresholds at 2, 4, and 8 kHz. ABRs were at least 7 dB lower at 16 kHz, and approximately 3 dB higher at 22 kHz. The better sensitivity of ABRs at higher frequencies could have reflected differences in the seal's behavior during ABR testing and/or bandwidth characteristics of test stimuli. These results agree with comparisons of ABR and behavioral methods performed in other recent studies and indicate that ABR methods represent a good alternative for estimating hearing range and sensitivity in pinnipeds, particularly when time is a critical factor and animals are untrained.

  20. Inverse correlation between the standard deviation of R-R intervals in supine position and the simplified menopausal index in women with climacteric symptoms.

    PubMed

    Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio

    2014-06-01

    Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P < 0.01, 0.05, and 0.001, respectively) decreased in women with climacteric symptoms. There was a negative correlation between the standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.

  1. Conversion and matched filter approximations for serial minimum-shift keyed modulation

    NASA Technical Reports Server (NTRS)

    Ziemer, R. E.; Ryan, C. R.; Stilwell, J. H.

    1982-01-01

    Serial minimum-shift keyed (MSK) modulation, a technique for generating and detecting MSK using series filtering, is ideally suited for high data rate applications provided the required conversion and matched filters can be closely approximated. Low-pass implementations of these filters as parallel inphase- and quadrature-mixer structures are characterized in this paper in terms of signal-to-noise ratio (SNR) degradation from ideal and envelope deviation. Several hardware implementation techniques utilizing microwave devices or lumped elements are presented. Optimization of parameter values results in realizations whose SNR degradation is less than 0.5 dB at error probabilities of .000001.

  2. Low-noise correlation measurements based on software-defined-radio receivers and cooled microwave amplifiers.

    PubMed

    Nieminen, Teemu; Lähteenmäki, Pasi; Tan, Zhenbing; Cox, Daniel; Hakonen, Pertti J

    2016-11-01

    We present a microwave correlation measurement system based on two low-cost USB-connected software defined radio dongles modified to operate as coherent receivers by using a common local oscillator. Existing software is used to obtain I/Q samples from both dongles simultaneously at a software tunable frequency. To achieve low noise, we introduce an easy low-noise solution for cryogenic amplification at 600-900 MHz based on single discrete HEMT with 21 dB gain and 7 K noise temperature. In addition, we discuss the quantization effects in a digital correlation measurement and determination of optimal integration time by applying Allan deviation analysis.

  3. Glaucomatous Visual Field Loss Associated with Less Travel from Home

    PubMed Central

    Ramulu, Pradeep Y.; Hochberg, Chad; Maul, Eugenio A.; Chan, Emilie S.; Ferrucci, Luigi; Friedman, David S.

    2014-01-01

    Purpose To determine the association between glaucoma and travel away from home. Methods Fifty-nine glaucoma suspect controls with normal vision and 80 glaucoma subjects with bilateral visual field (VF) loss wore a cellular tracking device over 1 week of normal activity. Location data was used to evaluate the number of daily excursions away from home as well as daily time spent away from home. Results Control and glaucoma subjects were similar in age, race, gender, employment, driving support, cognitive ability, mood, and comorbid illness (p>0.1 for all). Better-eye VF mean deviation (MD) averaged 0.0 decibels (dB) in controls and –11.1 dB in glaucoma subjects. In multivariable models, glaucoma was associated with fewer daily excursions (β= -0.20; 95% CI=-0.38 to -0.02) and a greater likelihood of not leaving home on a given day (Odds ratio [OR]=1.82; 95% CI=1.05 to 3.06). Each 5 dB decrement in the better-eye VF MD was associated with fewer daily excursions (β= -0.06; 95% CI=-0.11 to -0.01) and a greater chance of not leaving home on a given day (OR=1.24; 95% CI=1.04 to 1.47). Time spent away from home did not significantly differ between the glaucoma subjects and suspects (p=0.18). However, each 5 dB decrement in the better-eye MD was associated with 6% less time away (95% CI=-12 to -1%). Conclusions Individuals with glaucoma, particularly those with greater VF loss, are more home-bound and travel away from home less than individuals with normal vision. Since being confined to the home environment may have detrimental effects on fitness and health, individuals with glaucoma should be considered for interventions such as orientation and mobility training to encourage safe travel away from home. PMID:24374635

  4. The effect of mitomycin C trabeculectomy on the progression of visual field defect in normal-tension glaucoma.

    PubMed

    Hagiwara, Y; Yamamoto, T; Kitazawa, Y

    2000-03-01

    We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.

  5. Soiling of building envelope surfaces and its effect on solar reflectance – Part III: Interlaboratory study of an accelerated aging method for roofing materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.

    A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less

  6. Software Update.

    ERIC Educational Resources Information Center

    Currents, 2000

    2000-01-01

    A chart of 40 alumni-development database systems provides information on vendor/Web site, address, contact/phone, software name, price range, minimum suggested workstation/suggested server, standard reports/reporting tools, minimum/maximum record capacity, and number of installed sites/client type. (DB)

  7. SNR and Standard Deviation of cGNSS-R and iGNSS-R Scatterometric Measurements.

    PubMed

    Alonso-Arroyo, Alberto; Querol, Jorge; Lopez-Martinez, Carlos; Zavorotny, Valery U; Park, Hyuk; Pascual, Daniel; Onrubia, Raul; Camps, Adriano

    2017-01-19

    This work addresses the accuracy of the Global Navigation Satellite Systems (GNSS)-Reflectometry (GNSS-R) scatterometric measurements considering the presence of both coherent and incoherent scattered components, for both conventional GNSS-R (cGNSS-R) and interferometric GNSS-R (iGNSS-R) techniques. The coherent component is present for some type of surfaces, and it has been neglected until now because it vanishes for the sea surface scattering case. Taking into account the presence of both scattering components, the estimated Signal-to-Noise Ratio (SNR) for both techniques is computed based on the detectability criterion, as it is done in conventional GNSS applications. The non-coherent averaging operation is considered from a general point of view, taking into account that thermal noise contributions can be reduced by an extra factor of 0.88 dB when using partially overlapped or partially correlated samples. After the SNRs are derived, the received waveform's peak variability is computed, which determines the system's capability to measure geophysical parameters. This theoretical derivations are applied to the United Kingdom (UK) TechDemoSat-1 (UK TDS-1) and to the future GNSS REflectometry, Radio Occultation and Scatterometry on board the International Space Station (ISS) (GEROS-ISS) scenarios, in order to estimate the expected scatterometric performance of both missions.

  8. A descriptive study of noise in the neonatal intensive care unit: ambient levels and perceptions of contributing factors.

    PubMed

    Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J

    2008-10-01

    To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics-recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated. Elevated sound levels need to be addressed in individual NICUs around the country. Further exploratory studies, as well as research regarding effective methods of decreasing sound levels in the NICU environment, are necessary. NICUs can implement behavioral and structural changes that can decrease the sound levels in the NICU environment and decrease the potential for exposure of patients to the harmful physiological effects of increased sound levels.

  9. A descriptive study of noise in the neonatal intensive care unit. Ambient levels and perceptions of contributing factors.

    PubMed

    Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J

    2008-06-01

    To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics--recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated. Elevated sound levels need to be addressed in individual NICUs around the country. Further exploratory studies, as well as research regarding effective methods of decreasing sound levels in the NICU environment, are necessary. NICUs can implement behavioral and structural changes that can decrease the sound levels in the NICU environment and decrease the potential for exposure of patients to the harmful physiological effects of increased sound levels.

  10. Selection and Classification Using a Forecast Applicant Pool.

    ERIC Educational Resources Information Center

    Hendrix, William H.

    The document presents a forecast model of the future Air Force applicant pool. By forecasting applicants' quality (means and standard deviations of aptitude scores) and quantity (total number of applicants), a potential enlistee could be compared to the forecasted pool. The data used to develop the model consisted of means, standard deviation, and…

  11. Test of the principle of operation of a wideband magnetic direction finder for lightning return strokes

    NASA Technical Reports Server (NTRS)

    Herrman, B. D.; Uman, M. A.; Brantley, R. D.; Krider, E. P.

    1976-01-01

    The principle of operation of a wideband crossed-loop magnetic-field direction finder is studied by comparing the bearing determined from the NS and EW magnetic fields at various times up to 155 microsec after return stroke initiation with the TV-determined lightning channel base direction. For 40 lightning strokes in the 3 to 12 km range, the difference between the bearings found from magnetic fields sampled at times between 1 and 10 microsec and the TV channel-base data has a standard deviation of 3-4 deg. Included in this standard deviation is a 2-3 deg measurement error. For fields sampled at progressively later times, both the mean and the standard deviation of the difference between the direction-finder bearing and the TV bearing increase. Near 150 microsec, means are about 35 deg and standard deviations about 60 deg. The physical reasons for the late-time inaccuracies in the wideband direction finder and the occurrence of these effects in narrow-band VLF direction finders are considered.

  12. Wavelength selection method with standard deviation: application to pulse oximetry.

    PubMed

    Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija

    2011-07-01

    Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.

  13. How random is a random vector?

    NASA Astrophysics Data System (ADS)

    Eliazar, Iddo

    2015-12-01

    Over 80 years ago Samuel Wilks proposed that the "generalized variance" of a random vector is the determinant of its covariance matrix. To date, the notion and use of the generalized variance is confined only to very specific niches in statistics. In this paper we establish that the "Wilks standard deviation" -the square root of the generalized variance-is indeed the standard deviation of a random vector. We further establish that the "uncorrelation index" -a derivative of the Wilks standard deviation-is a measure of the overall correlation between the components of a random vector. Both the Wilks standard deviation and the uncorrelation index are, respectively, special cases of two general notions that we introduce: "randomness measures" and "independence indices" of random vectors. In turn, these general notions give rise to "randomness diagrams"-tangible planar visualizations that answer the question: How random is a random vector? The notion of "independence indices" yields a novel measure of correlation for Lévy laws. In general, the concepts and results presented in this paper are applicable to any field of science and engineering with random-vectors empirical data.

  14. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.

    PubMed

    Hasija, Narender; Bala, Madhu; Goyal, Virender

    2014-05-01

    Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.

  15. Association of auricular pressing and heart rate variability in pre-exam anxiety students.

    PubMed

    Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong

    2013-03-25

    A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety.

  16. Association of auricular pressing and heart rate variability in pre-exam anxiety students

    PubMed Central

    Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong

    2013-01-01

    A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety. PMID:25206734

  17. Offshore fatigue design turbulence

    NASA Astrophysics Data System (ADS)

    Larsen, Gunner C.

    2001-07-01

    Fatigue damage on wind turbines is mainly caused by stochastic loading originating from turbulence. While onshore sites display large differences in terrain topology, and thereby also in turbulence conditions, offshore sites are far more homogeneous, as the majority of them are likely to be associated with shallow water areas. However, despite this fact, specific recommendations on offshore turbulence intensities, applicable for fatigue design purposes, are lacking in the present IEC code. This article presents specific guidelines for such loading. These guidelines are based on the statistical analysis of a large number of wind data originating from two Danish shallow water offshore sites. The turbulence standard deviation depends on the mean wind speed, upstream conditions, measuring height and thermal convection. Defining a population of turbulence standard deviations, at a given measuring position, uniquely by the mean wind speed, variations in upstream conditions and atmospheric stability will appear as variability of the turbulence standard deviation. Distributions of such turbulence standard deviations, conditioned on the mean wind speed, are quantified by fitting the measured data to logarithmic Gaussian distributions. By combining a simple heuristic load model with the parametrized conditional probability density functions of the turbulence standard deviations, an empirical offshore design turbulence intensity is determined. For pure stochastic loading (as associated with standstill situations), the design turbulence intensity yields a fatigue damage equal to the average fatigue damage caused by the distributed turbulence intensity. If the stochastic loading is combined with a periodic deterministic loading (as in the normal operating situation), the proposed design turbulence intensity is shown to be conservative.

  18. Estimating extreme stream temperatures by the standard deviate method

    NASA Astrophysics Data System (ADS)

    Bogan, Travis; Othmer, Jonathan; Mohseni, Omid; Stefan, Heinz

    2006-02-01

    It is now widely accepted that global climate warming is taking place on the earth. Among many other effects, a rise in air temperatures is expected to increase stream temperatures indefinitely. However, due to evaporative cooling, stream temperatures do not increase linearly with increasing air temperatures indefinitely. Within the anticipated bounds of climate warming, extreme stream temperatures may therefore not rise substantially. With this concept in mind, past extreme temperatures measured at 720 USGS stream gauging stations were analyzed by the standard deviate method. In this method the highest stream temperatures are expressed as the mean temperature of a measured partial maximum stream temperature series plus its standard deviation multiplied by a factor KE (standard deviate). Various KE-values were explored; values of KE larger than 8 were found physically unreasonable. It is concluded that the value of KE should be in the range from 7 to 8. A unit error in estimating KE translates into a typical stream temperature error of about 0.5 °C. Using a logistic model for the stream temperature/air temperature relationship, a one degree error in air temperature gives a typical error of 0.16 °C in stream temperature. With a projected error in the enveloping standard deviate dKE=1.0 (range 0.5-1.5) and an error in projected high air temperature d Ta=2 °C (range 0-4 °C), the total projected stream temperature error is estimated as d Ts=0.8 °C.

  19. Herschel Extreme Lensing Line Observations: Dynamics of Two Strongly Lensed Star-Forming Galaxies near Redshift z=2*

    NASA Technical Reports Server (NTRS)

    Rhoads, James E.; Rigby, Jane Rebecca; Malhotra, Sangeeta; Allam, Sahar; Carilli, Chris; Combes, Francoise; Finkelstein, Keely; Finkelstein, Steven; Frye, Brenda; Gerin, Maryvonne; hide

    2014-01-01

    We report on two regularly rotating galaxies at redshift z approx. = 2, using high-resolution spectra of the bright [C microns] 158 micrometers emission line from the HIFI instrument on the Herschel Space Observatory. Both SDSS090122.37+181432.3 ("S0901") and SDSSJ120602.09+514229.5 ("the Clone") are strongly lensed and show the double-horned line profile that is typical of rotating gas disks. Using a parametric disk model to fit the emission line profiles, we find that S0901 has a rotation speed of v sin(i) approx. = 120 +/- 7 kms(sup -1) and a gas velocity dispersion of (standard deviation)g < 23 km s(sup -1) (1(standard deviation)). The best-fitting model for the Clone is a rotationally supported disk having v sin(i) approx. = 79 +/- 11 km s(sup -1) and (standard deviation)g 4 kms(sup -1) (1(standard deviation)). However, the Clone is also consistent with a family of dispersion-dominated models having (standard deviation)g = 92 +/- 20 km s(sup -1). Our results showcase the potential of the [C microns] line as a kinematic probe of high-redshift galaxy dynamics: [C microns] is bright, accessible to heterodyne receivers with exquisite velocity resolution, and traces dense star-forming interstellar gas. Future [C microns] line observations with ALMA would offer the further advantage of spatial resolution, allowing a clearer separation between rotation and velocity dispersion.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fried, D; Meier, J; Mawlawi, O

    Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was ablemore » to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by <1SUV and <2SUV ranged from 61–92% and 88–99%, respectively. Voxel-voxel similarity decreased when using higher resolution image matrices (192/256 versus 128) and was comparable across scanners. Taking the ratio of patient and phantom feature standard deviation was able to identify features that were not robust to changes in reconstruction parameters (e.g. co-occurrence correlation). Metrics found to be reasonably robust (standard deviation ratios > 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of feature variability across scanners and was able to identify features that were not robust to changes in reconstruction parameters.« less

  1. Host model uncertainties in aerosol radiative forcing estimates: results from the AeroCom prescribed intercomparison study

    NASA Astrophysics Data System (ADS)

    Stier, P.; Schutgens, N. A. J.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Myhre, G.; Penner, J. E.; Randles, C.; Samset, B.; Schulz, M.; Yu, H.; Zhou, C.

    2012-09-01

    Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in nine participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.51 W m-2 and the inter-model standard deviation is 0.70 W m-2, corresponding to a relative standard deviation of 15%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.26 W m-2, and the standard deviation increases to 1.21 W m-2, corresponding to a significant relative standard deviation of 96%. However, the top-of-atmosphere forcing variability owing to absorption is low, with relative standard deviations of 9% clear-sky and 12% all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment, demonstrates that host model uncertainties could explain about half of the overall sulfate forcing diversity of 0.13 W m-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.

  2. Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data

    NASA Astrophysics Data System (ADS)

    Shulenin, V. P.

    2016-10-01

    Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.

  3. 40 CFR 63.7751 - What reports must I submit and when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... deviations from any emissions limitations (including operating limit), work practice standards, or operation and maintenance requirements, a statement that there were no deviations from the emissions limitations...-of-control during the reporting period. (7) For each deviation from an emissions limitation...

  4. A multivariate and stochastic approach to identify key variables to rank dairy farms on profitability.

    PubMed

    Atzori, A S; Tedeschi, L O; Cannas, A

    2013-05-01

    The economic efficiency of dairy farms is the main goal of farmers. The objective of this work was to use routinely available information at the dairy farm level to develop an index of profitability to rank dairy farms and to assist the decision-making process of farmers to increase the economic efficiency of the entire system. A stochastic modeling approach was used to study the relationships between inputs and profitability (i.e., income over feed cost; IOFC) of dairy cattle farms. The IOFC was calculated as: milk revenue + value of male calves + culling revenue - herd feed costs. Two databases were created. The first one was a development database, which was created from technical and economic variables collected in 135 dairy farms. The second one was a synthetic database (sDB) created from 5,000 synthetic dairy farms using the Monte Carlo technique and based on the characteristics of the development database data. The sDB was used to develop a ranking index as follows: (1) principal component analysis (PCA), excluding IOFC, was used to identify principal components (sPC); and (2) coefficient estimates of a multiple regression of the IOFC on the sPC were obtained. Then, the eigenvectors of the sPC were used to compute the principal component values for the original 135 dairy farms that were used with the multiple regression coefficient estimates to predict IOFC (dRI; ranking index from development database). The dRI was used to rank the original 135 dairy farms. The PCA explained 77.6% of the sDB variability and 4 sPC were selected. The sPC were associated with herd profile, milk quality and payment, poor management, and reproduction based on the significant variables of the sPC. The mean IOFC in the sDB was 0.1377 ± 0.0162 euros per liter of milk (€/L). The dRI explained 81% of the variability of the IOFC calculated for the 135 original farms. When the number of farms below and above 1 standard deviation (SD) of the dRI were calculated, we found that 21 farms had dRI<-1 SD, 32 farms were between -1 SD and 0, 67 farms were between 0 and +1 SD, and 15 farms had dRI>+1 SD. The top 10% of the farms had a dRI greater than 0.170 €/L, whereas the bottom 10% farms had a dRI lower than 0.116 €/L. This stochastic approach allowed us to understand the relationships among the inputs of the studied dairy farms and to develop a ranking index for comparison purposes. The developed methodology may be improved by using more inputs at the dairy farm level and considering the actual cost to measure profitability. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Classification of Chemicals Based On Structured Toxicity Information

    EPA Science Inventory

    Thirty years and millions of dollars worth of pesticide registration toxicity studies, historically stored as hardcopy and scanned documents, have been digitized into highly standardized and structured toxicity data within the Toxicity Reference Database (ToxRefDB). Toxicity-bas...

  6. Citing Legal Material in APA Journals.

    ERIC Educational Resources Information Center

    Osborne, Allan G., Jr.

    1992-01-01

    Guidelines are offered to authors on the correct citation format for legal references, including statutes and regulations, court decisions, and law review articles. Standards are based on those published by the Harvard Law Review Association and the American Psychological Association. (DB)

  7. The Investment Decision: Theory and Practice.

    ERIC Educational Resources Information Center

    Walton, Martin

    1978-01-01

    Investigates investment behavior of 42 British business firms to determine the degree to which firms are influenced by standard economic theory. Findings indicated that orthodox economic theories of investment and appraisal techniques have little influence on investment behavior. (Author/DB)

  8. A fuzzy logic-based model for noise control at industrial workplaces.

    PubMed

    Aluclu, I; Dalgic, A; Toprak, Z F

    2008-05-01

    Ergonomics is a broad science encompassing the wide variety of working conditions that can affect worker comfort and health, including factors such as lighting, noise, temperature, vibration, workstation design, tool design, machine design, etc. This paper describes noise-human response and a fuzzy logic model developed by comprehensive field studies on noise measurements (including atmospheric parameters) and control measures. The model has two subsystems constructed on noise reduction quantity in dB. The first subsystem of the fuzzy model depending on 549 linguistic rules comprises acoustical features of all materials used in any workplace. Totally 984 patterns were used, 503 patterns for model development and the rest 481 patterns for testing the model. The second subsystem deals with atmospheric parameter interactions with noise and has 52 linguistic rules. Similarly, 94 field patterns were obtained; 68 patterns were used for training stage of the model and the rest 26 patterns for testing the model. These rules were determined by taking into consideration formal standards, experiences of specialists and the measurements patterns. The results of the model were compared with various statistics (correlation coefficients, max-min, standard deviation, average and coefficient of skewness) and error modes (root mean square error and relative error). The correlation coefficients were significantly high, error modes were quite low and the other statistics were very close to the data. This statement indicates the validity of the model. Therefore, the model can be used for noise control in any workplace and helpful to the designer in planning stage of a workplace.

  9. Contrast visual acuity in patients with retinitis pigmentosa assessed by a contrast sensitivity tester.

    PubMed

    Oishi, Maho; Nakamura, Hajime; Hangai, Masanori; Oishi, Akio; Otani, Atsushi; Yoshimura, Nagahisa

    2012-01-01

    To assess contrast visual acuity (CVA) in patients with retinitis pigmentosa (RP) and compare the result with standard visual acuity (VA), retinal thickness, status of inner segment/outer segment junction, and central visual field. Thirty-nine eyes of 39 patients with RP and 39 eyes of 39 healthy individuals were studied. To see the difference in CVA between RP patients and normal controls, only subjects with standard VA of 1.0 (20/20) or better were included. This was a cross-sectional study. CVA in various light conditions was measured with CAT-2000 and was compared between patients and controls. CVA of patients was further analyzed for association with other parameters including foveal retinal thickness, outer nuclear layer thickness, the status of inner segment/outer segment junction measured with optical coherence tomography (OCT), and visual field mean deviation (MD) measured with Humphrey field analyzer 10-2 program. CVA impairment was evident in RP patients compared to controls (P < 0.01, in all measurement conditions). Multivariate analysis showed association of logarithm of the minimum angle of resolution (logMAR) with CVAs in several conditions. None of the OCT measurements was associated with CVA. When patients were divided into three groups based on MD, the most advanced group (MD worse than or equal to -20 dB) showed impairment of mesopic CVA (P < 0.05, under mesopic condition of 100% without glare, with glare, and 25% without glare). CVA impairment was confirmed in RP patients, especially in advanced cases. CVA measured with CAT-2000 may be a useful tool for assessing foveal function in RP patients.

  10. AtomDB: Expanding an Accessible and Accurate Atomic Database for X-ray Astronomy

    NASA Astrophysics Data System (ADS)

    Smith, Randall

    Since its inception in 2001, the AtomDB has become the standard repository of accurate and accessible atomic data for the X-ray astrophysics community, including laboratory astrophysicists, observers, and modelers. Modern calculations of collisional excitation rates now exist - and are in AtomDB - for all abundant ions in a hot plasma. AtomDB has expanded beyond providing just a collisional model, and now also contains photoionization data from XSTAR as well as a charge exchange model, amongst others. However, building and maintaining an accurate and complete database that can fully exploit the diagnostic potential of high-resolution X-ray spectra requires further work. The Hitomi results, sadly limited as they were, demonstrated the urgent need for the best possible wavelength and rate data, not merely for the strongest lines but for the diagnostic features that may have 1% or less of the flux of the strong lines. In particular, incorporation of weak but powerfully diagnostic satellite lines will be crucial to understanding the spectra expected from upcoming deep observations with Chandra and XMM-Newton, as well as the XARM and Athena satellites. Beyond incorporating this new data, a number of groups, both experimental and theoretical, have begun to produce data with errors and/or sensitivity estimates. We plan to use this to create statistically meaningful spectral errors on collisional plasmas, providing practical uncertainties together with model spectra. We propose to continue to (1) engage the X-ray astrophysics community regarding their issues and needs, notably by a critical comparison with other related databases and tools, (2) enhance AtomDB to incorporate a large number of satellite lines as well as updated wavelengths with error estimates, (3) continue to update the AtomDB with the latest calculations and laboratory measurements, in particular velocity-dependent charge exchange rates, and (4) enhance existing tools, and create new ones as needed to increase the functionality of, and access to, AtomDB.

  11. Use of Standard Deviations as Predictors in Models Using Large-Scale International Data Sets

    ERIC Educational Resources Information Center

    Austin, Bruce; French, Brian; Adesope, Olusola; Gotch, Chad

    2017-01-01

    Measures of variability are successfully used in predictive modeling in research areas outside of education. This study examined how standard deviations can be used to address research questions not easily addressed using traditional measures such as group means based on index variables. Student survey data were obtained from the Organisation for…

  12. Screen Twice, Cut Once: Assessing the Predictive Validity of Teacher Selection Tools

    ERIC Educational Resources Information Center

    Goldhaber, Dan; Grout, Cyrus; Huntington-Klein, Nick

    2015-01-01

    It is well documented that teachers can have profound effects on student outcomes. Empirical estimates find that a one standard deviation increase in teacher quality raises student test achievement by 10 to 25 percent of a standard deviation. More recent evidence shows that the effectiveness of teachers can affect long-term student outcomes, such…

  13. Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes

    ERIC Educational Resources Information Center

    Zavorsky, Gerald S.

    2010-01-01

    Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…

  14. Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016

    NASA Astrophysics Data System (ADS)

    Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas

    2017-06-01

    A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.

  15. Benign positional vertigo and hyperuricaemia.

    PubMed

    Adam, A M

    2005-07-01

    To find out if there is any association between serum uric acid level and positional vertigo. A prospective, case controlled study. A private neurological clinic. All patients presenting with vertigo. Ninety patients were seen in this period with 78 males and 19 females. Mean age was 47 +/- 3 years (at 95% confidence level) with a standard deviation of 12.4. Their mean uric acid level was 442 +/- 16 (at 95% confidence level) with a standard deviation of 79.6 umol/l as compared to 291 +/- 17 (at 95% confidence level) with a standard deviation of 79.7 umol/l in the control group. The P-value was less than 0.001. That there is a significant association between high uric acid and benign positional vertigo.

  16. Palus Somni - Anomalies in the correlation of Al/Si X-ray fluorescence intensity ratios and broad-spectrum visible albedos. [lunar surface mineralogy

    NASA Technical Reports Server (NTRS)

    Clark, P. E.; Andre, C. G.; Adler, I.; Weidner, J.; Podwysocki, M.

    1976-01-01

    The positive correlation between Al/Si X-ray fluorescence intensity ratios determined during the Apollo 15 lunar mission and a broad-spectrum visible albedo of the moon is quantitatively established. Linear regression analysis performed on 246 1 degree geographic cells of X-ray fluorescence intensity and visible albedo data points produced a statistically significant correlation coefficient of .78. Three distinct distributions of data were identified as (1) within one standard deviation of the regression line, (2) greater than one standard deviation below the line, and (3) greater than one standard deviation above the line. The latter two distributions of data were found to occupy distinct geographic areas in the Palus Somni region.

  17. Screening Samples for Arsenic by Inductively Coupled Plasma-Mass Spectrometry for Treaty Samples

    DTIC Science & Technology

    2014-02-01

    2.274 3.657 10.06 14.56 30.36 35.93 % RSD : 15.87% 4.375% 2.931% 4.473% 3.349% 3.788% 2.802% 3.883% 3.449% RSD , relative standard deviation 9   Table...107.9% 106.4% Standard Deviation: 0.3171 0.3498 0.8024 2.964 4.526 10.06 13.83 16.38 11.81 % RSD : 5.657% 3.174% 3.035% 5.507% 4.332% 3.795% 2.626...119.1% 116.5% 109.4% 106.8% 105.2% 105.5% 105.8% 108.6% 107.8% Standard Deviation: 0.2379 0.5595 1.173 2.375 2.798 5.973 11.79 15.10 30.54 % RSD

  18. Enhanced visible photocatalytic activity of cotton ball like nano structured Cu doped ZnO for the degradation of organic pollutant.

    PubMed

    Thennarasu, G; Sivasamy, A

    2016-12-01

    Stringent Environmental standards followed worldwide led to the emergence of advanced oxidation process for the removal of toxic contaminants from water and wastewater. Among all semiconductor photocatalysts have great potential in the degradation of organic and inorganic pollutants into lesser harmful products under visible light irradiations. The present research work describes the synthesis of Cu doped ZnO (CuDZ) via a co-precipitation method to attain high crystallized powder confirmed by XRD analysis. The FE-SEM images showed that the CuDZ has cotton ball like morphology with a uniform size ranged from 25 to 40nm. TEM, FT-IR and UV-DRS studies of the synthesized CuDZ are also discussed in detail. The photocatalytic activity of the as prepared CuDZ catalyst was tested for the degradation of Direct Blue 71 (DB 71) dye in aqueous phase under visible light irradiation. The degree of degradation was found to be dependent on aqueous phase pH, duration of irradiation time, amount of photocatalyst, the initial dye concentration and kinetics of photodegradation. The maximum photocatytic degradation of DB 71 dye was found to be effective at pH 6.8. The optimum amount of photocatalyst was found 3gL -1 of CuDZ for the complete degradation of DB 71 dye (0.01gL -1 ). The reusability of the photocatalyst indicates that 96% of DB 71 dye was degraded up to 3rd cycles of use. The visible photodegradation of DB 71 dye was exhibited pseudo-first-order kinetics. Chemical oxygen demand and ESI-MS studies confirmed the complete mineralization of DB 71 dye molecules. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Impact of scar thickness on the assessment of viability using dobutamine echocardiography and thallium single-photon emission computed tomography: a comparison with contrast-enhanced magnetic resonance imaging.

    PubMed

    Nelson, Charles; McCrohon, Jane; Khafagi, Frederick; Rose, Stephen; Leano, Rodel; Marwick, Thomas H

    2004-04-07

    We sought to determine whether the transmural extent of scar (TES) explains discordances between dobutamine echocardiography (DbE) and thallium single-photon emission computed tomography (Tl-SPECT) in the detection of viable myocardium (VM). Discrepancies between DbE and Tl-SPECT are often attributed to differences between contractile reserve and membrane integrity, but may also reflect a disproportionate influence of nontransmural scar on thickening at DbE. Sixty patients (age 62 +/- 12 years; 10 women and 50 men) with postinfarction left ventricular dysfunction underwent standard rest-late redistribution Tl-SPECT and DbE. Viable myocardium was identified when dysfunctional segments showed Tl activity >60% on the late-redistribution image or by low-dose augmentation at DbE. Contrast-enhanced magnetic resonance imaging (ceMRI) was used to divide TES into five groups: 0%, <25%, 26% to 50%, 51% to 75%, and >75% of the wall thickness replaced by scar. As TES increased, both the mean Tl uptake and change in wall motion score decreased significantly (both p < 0.001). However, the presence of subendocardial scar was insufficient to prevent thickening; >50% of segments still showed contractile function with TES of 25% to 75%, although residual function was uncommon with TES >75%. The relationship of both tests to increasing TES was similar, but Tl-SPECT identified VM more frequently than DbE in all groups. Among segments without scar or with small amounts of scar (<25% TES), >50% were viable by SPECT. Both contractile reserve and perfusion are sensitive to the extent of scar. However, contractile reserve may be impaired in the face of no or minor scar, and thickening may still occur with extensive scar.

  20. A deviation display method for visualising data in mobile gamma-ray spectrometry.

    PubMed

    Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer

    2010-09-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  1. A randomized controlled trial investigating the effects of craniosacral therapy on pain and heart rate variability in fibromyalgia patients.

    PubMed

    Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen

    2011-01-01

    Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.

  2. 41 CFR 102-38.30 - How does an executive agency request a deviation from the provisions of this part?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... which are distinct from the standard deviation process and specific to the requirements of the Federal... agency request a deviation from the provisions of this part? 102-38.30 Section 102-38.30 Public Contracts... executive agency request a deviation from the provisions of this part? Refer to §§ 102-2.60 through 102-2...

  3. Multivariate data analysis to characterize gas chromatography columns for dioxin analysis.

    PubMed

    Do, Lan; Geladi, Paul; Haglund, Peter

    2014-06-20

    Principal component analysis (PCA) was applied for evaluating the selectivity of 22 GC columns for which complete retention data were available for the 136 tetra- to octa-chlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Because the hepta- and octa-homologues are easy to separate the PCA was focused on the 128 tetra- to hexa-CDD/Fs. The analysis showed that 21 of the 22 GC columns could be subdivided into four groups with different selectivity. Group I consists of columns with non-polar thermally stable phases (Restek 5Sil MS and Dioxin 2, SGE BPX-DXN, Supelco Equity-5, and Agilent DB-1, DB-5, DB-5ms, VF-5ms, VF-Xms and DB-XLB). Group II includes ionic liquid columns (Supelco SLB-IL61, SLB-IL111 and SLB-IL76) with very high polarity. Group III includes columns with high-percentage phenyl and cyanopropyl phases (Agilent DB-17 and DB-225, Quadrex CPS-1, Supelco SP-2331, and Agilent CP-Sil 88), and Group IV columns with shape selectivity (Dionex SB-Smectic and Restek LC-50, Supelco βDEXcst, Agilent VF-Xms and DB-XLB). Thus, two columns appeared in both Group I and IV (Agilent VF-Xms and DB-XLB). The selectivity of the other column, Agilent DB-210, differs from those of these four groups. Partial least squares (PLS) regression was used to correlate the retention times of the tetra- to hexa-CDD/Fs on the 22 stationary phases with a set of physicochemical and structural descriptors to identify parameters that significantly influence the solute-stationary phase interactions. The most influential physicochemical parameters for the interaction were associated with molecular size (as reflects in the total energy, electron energy, core-core repulsion and standard entropy), solubility (aqueous solubility and n-octanol/water partition coefficient), charge distribution (molecular polarizability and dipolar moment), and reactivity (relative Gibbs free energy); and the most influential structural descriptors were related to these parameters, in particular, size and dipolar moment. Finally, the PCA and PLS analyses were complemented with linear regression analysis to identify the most orthogonal column combinations, which could be used in comprehensive two-dimensional gas chromatography (GC×GC) to enhance PCDD/F separation and congener profiling. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Quantifying Fall-Related Hazards in the Homes of Persons with Glaucoma.

    PubMed

    Yonge, Andrea V; Swenor, Bonnielin K; Miller, Rhonda; Goldhammer, Victoria; West, Sheila K; Friedman, David S; Gitlin, Laura N; Ramulu, Pradeep Y

    2017-04-01

    To characterize fall-related hazards in the homes of persons with suspected or diagnosed glaucoma, and to determine whether those with worse visual field (VF) damage have fewer home hazards. Cross-sectional study using baseline (2013-2015) data from the ongoing Falls in Glaucoma Study (FIGS). One-hundred seventy-four of 245 (71.0%) FIGS participants agreeing to the home assessment. Participants' homes were assessed using the Home Environment Assessment for the Visually Impaired (HEAVI). A single evaluator assessed up to 127 potential hazards in 8 home regions. In the clinic, binocular contrast sensitivity (CS) and better-eye visual acuity (VA) were evaluated, and 24-2 VFs were obtained to calculate average integrated VF (IVF) sensitivity. Total number of home hazards. No significant visual or demographic differences were noted between participants who did and did not complete the home assessment (P > 0.09 for all measures). Mean age among those completing the home assessment (n = 174) was 71.1 years, and IVF sensitivity ranged from 5.6 to 33.4 dB (mean = 27.2 dB, standard deviation [SD] = 4.0 dB). The mean number of items graded per home was 85.2 (SD = 13.2), and an average of 32.7 (38.3%) were identified as hazards. IVF sensitivity, CS, and VA were not associated with total home hazards or the number of hazards in any given room (P > 0.06 for all visual measures and rooms). The bathroom contained the greatest number of hazards (mean = 7.9; 54.2% of graded items classified as hazardous), and the most common hazards identified in at least 1 room were ambient lighting <300 lux and exposed light bulbs. Only 27.9% of graded rooms had adequate lighting. IVF sensitivity, CS, and VA were not associated with home lighting levels (P > 0.18 for all), but brighter room lighting was noted in the homes of participants with higher median income (P < 0.001). Multiple home fall hazards were identified in the study population, and hazard numbers were not lower for persons with worse VF damage, suggesting that individuals with more advanced glaucoma do not adapt their homes for safety. Further work should investigate whether addressing home hazards is an effective intervention for preventing falls in this high-risk group. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  5. Family structure and childhood anthropometry in Saint Paul, Minnesota in 1918

    PubMed Central

    Warren, John Robert

    2017-01-01

    Concern with childhood nutrition prompted numerous surveys of children’s growth in the United States after 1870. The Children’s Bureau’s 1918 “Weighing and Measuring Test” measured two million children to produce the first official American growth norms. Individual data for 14,000 children survives from the Saint Paul, Minnesota survey whose stature closely approximated national norms. As well as anthropometry the survey recorded exact ages, street address and full name. These variables allow linkage to the 1920 census to obtain demographic and socioeconomic information. We matched 72% of children to census families creating a sample of nearly 10,000 children. Children in the entire survey (linked set) averaged 0.74 (0.72) standard deviations below modern WHO height-for-age standards, and 0.48 (0.46) standard deviations below modern weight-for-age norms. Sibship size strongly influenced height-for-age, and had weaker influence on weight-for-age. Each additional child six or underreduced height-for-age scores by 0.07 standard deviations (95% CI: −0.03, 0.11). Teenage siblings had little effect on height-forage. Social class effects were substantial. Children of laborers averaged half a standard deviation shorter than children of professionals. Family structure and socio-economic status had compounding impacts on children’s stature. PMID:28943749

  6. Occupational injury and illness recording and reporting requirements. Final rule.

    PubMed

    2002-07-01

    The Occupational Safety and Health Administration (OSHA) is revising the hearing loss recording provisions of the Occupational Injury and Illness Recording and Reporting Requirements rule published January 19, 2001 (66 FR 5916-6135), scheduled to take effect on January 1, 2003 (66 FR 52031-52034). This final rule revises the criteria for recording hearing loss cases in several ways, including requiring the recording of Standard Threshold Shifts (10 dB shifts in hearing acuity) that have resulted in a total 25 dB level of hearing above audiometric zero, averaged over the frequencies at 2000, 3000, and 4000 Hz, beginning in year 2003.

  7. Slotted Polyimide-Aerogel-Filled-Waveguide Arrays

    NASA Technical Reports Server (NTRS)

    Rodriguez-Solis, Rafael A.; Pacheco, Hector L.; Miranda, Felix A.; Meador, Mary Ann B.

    2013-01-01

    Polyimide aerogels were considered to serve as a filling for millimeter-wave waveguides. While these waveguides present a slightly higher loss than hollow waveguides, they have less losses than Duroid substrate integrated waveguides (less than 0.15 dB at Ka-band, in a 20 mm section), and exhibit an order of magnitude of mass reduction when compared to commercial waveguides. A Ka-band slotted aerogel-filled-waveguide array was designed, which provided the same gain (9 dBi) as its standard waveguide counterpart, and a slotted aerogel-filled-waveguide array using folded-slots was designed for comparison, obtaining a gain of 9 dB and a bandwidth of 590 MHz.

  8. Frequency noise suppression of a single mode laser with an unbalanced fiber interferometer for subnanometer interferometry.

    PubMed

    Šmíd, Radek; Čížek, Martin; Mikel, Břetislav; Číp, Ondřej

    2015-01-12

    We present a method of noise suppression of laser diodes by an unbalanced Michelson fiber interferometer. The unstabilized laser source is represented by compact planar waveguide external cavity laser module, ORIONTM (Redfern Integrated Optics, Inc.), working at 1540.57 nm with a 1.5-kHz linewidth. We built up the unbalanced Michelson interferometer with a 2.09 km-long arm based on the standard telecommunication single-mode fiber (SMF-28) spool to suppress the frequency noise by the servo-loop control by 20 dB to 40 dB within the Fourier frequency range, remaining the tuning range of the laser frequency.

  9. Models of Lift and Drag Coefficients of Stalled and Unstalled Airfoils in Wind Turbines and Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Spera, David A.

    2008-01-01

    Equations are developed with which to calculate lift and drag coefficients along the spans of torsionally-stiff rotating airfoils of the type used in wind turbine rotors and wind tunnel fans, at angles of attack in both the unstalled and stalled aerodynamic regimes. Explicit adjustments are made for the effects of aspect ratio (length to chord width) and airfoil thickness ratio. Calculated lift and drag parameters are compared to measured parameters for 55 airfoil data sets including 585 test points. Mean deviation was found to be -0.4 percent and standard deviation was 4.8 percent. When the proposed equations were applied to the calculation of power from a stall-controlled wind turbine tested in a NASA wind tunnel, mean deviation from 54 data points was -1.3 percent and standard deviation was 4.0 percent. Pressure-rise calculations for a large wind tunnel fan deviated by 2.7 percent (mean) and 4.4 percent (standard). The assumption that a single set of lift and drag coefficient equations can represent the stalled aerodynamic behavior of a wide variety of airfoils was found to be satisfactory.

  10. Optimizing otoacoustic emission protocols for a UNHS program.

    PubMed

    Hatzopoulos, S; Petruccelli, J; Ciorba, A; Martini, A

    2009-01-01

    To identify the optimal test protocol to screen for hearing problems in newborns, an evaluation of three distortion product otoacoustic emission (DPOAE) protocols was conducted in neonates, from a well-baby nursery (WBN) and from a neonatal intensive care unit (NICU) and compared to the performance in newborns of a more standard protocol based on transient-evoked OAEs (TEOAEs). The DPOAE protocols used asymmetrical stimulus intensities (L(1) > L(2)) with a frequency ratio of 1.22, in the following format: (P1), L(1) = 60, L(2) = 50 dB SPL; (P2), L(1) = 65, L(2) = 55 dB SPL, and (P3), L(1) = 75, L(2) = 65 dB SPL. Linear TEOAE responses, evoked by click stimuli of 75 dB peSPL, were used as controls of normal cochlear function. Five frequencies at 1.5, 2.0, 3.0, 4.0 and 5.0 kHz were tested with a common commercially available macro-based software subroutine (Otodynamics Corp, ILO-92). The project evaluated the responses from 1200 WBN infants (average age 48 h) and 350 low-birth-weight NICU infants, all randomly selected. Statistical analyses comparing the signal-to-noise ratios (S/N), at the predefined f(2) frequencies, indicated that the P1 and P2 DPOAE protocols generated similar responses. Significant S/N differences were observed in the P3 to P2 dataset comparisons. DPOAE scoring criteria were estimated from the P3 dataset using a one-sided, distribution-free confidence intervals. The scoring criteria for a 'pass' were estimated as a minimum S/N of 6.0, 7.0 and 6.0 dB at 2.0, 3.0 and 4.0 kHz, respectively. In terms of feasibility, the P3 protocol generated responses in 98% of the WBN and 94.8% of the NICU infants. All three DPOAE protocols demonstrated shorter time-recording requirements than the standard TEOAE test. The false-positive and false-negative rates for the NICU infants were estimated as 0.0028 and 0.003%, respectively.

  11. Event-Related Potential Measures of a Violation of an Expected Increase and Decrease in Intensity

    PubMed Central

    Macdonald, Margaret; Campbell, Kenneth

    2013-01-01

    Unexpected physical increases in the intensity of a frequently occurring “standard” auditory stimulus are experienced as obtrusive. This could either be because of a physical change, the increase in intensity of the “deviant” stimulus, or a psychological change, the violation of the expectancy for the occurrence of the lower intensity standard stimulus. Two experiments were run in which event-related potentials (ERPs) were recorded to determine whether “psychological” increments (violation of an expectancy for a lower intensity) would be processed differently than psychological decrements (violation of an expectancy for a higher intensity). Event-related potentials (ERPs) were recorded while subjects were presented with auditory tones that alternated between low and high intensity. The subjects ignored the auditory stimuli while watching a video. Deviants were created by repeating the same stimulus. In the first experiment, pairs of stimuli alternating in intensity, were presented in separate increment (H-L…H-L…H-H…H-L, in which H = 80 dB SPL and L = 60 dB SPL) and decrement conditions (L-H…L-H…L-L… L-H, in which H = 90 dB SPL and L = 80 dB SPL). The paradigm employed in the second experiment consisted of an alternating intensity pattern (H-L-H-L-H-H-H-L) or (H-L-H-L-L-L-H-L). Importantly, the stimulus prior to the deviant (the standard) and the actual deviants in both increment and decrement conditions in both experiments were physically identical (80 dB SPL tones). The repetition of the lower intensity tone therefore acted as a psychological rather than a physical decrement (a higher intensity tone was expected) while the repetition of the higher intensity tone acted as a psychological increment (a lower intensity tone was expected). The psychological increments in both experiments elicited a larger amplitude mismatch negativity (MMN) than the decrements. Thus, regardless of whether an acoustic change signals a physical increase in intensity or violates an expected decrease in intensity, a large MMN will be elicited. PMID:24143195

  12. Spatiotemporal Parameters are not Substantially Influenced by Load Carriage or Inclination During Treadmill and Overground Walking

    PubMed Central

    Seay, Joseph F.; Gregorczyk, Karen N.; Hasselquist, Leif

    2016-01-01

    Abstract Influences of load carriage and inclination on spatiotemporal parameters were examined during treadmill and overground walking. Ten soldiers walked on a treadmill and overground with three load conditions (00 kg, 20 kg, 40 kg) during level, uphill (6% grade) and downhill (-6% grade) inclinations at self-selected speed, which was constant across conditions. Mean values and standard deviations for double support percentage, stride length and a step rate were compared across conditions. Double support percentage increased with load and inclination change from uphill to level walking, with a 0.4% stance greater increase at the 20 kg condition compared to 00 kg. As inclination changed from uphill to downhill, the step rate increased more overground (4.3 ± 3.5 steps/min) than during treadmill walking (1.7 ± 2.3 steps/min). For the 40 kg condition, the standard deviations were larger than the 00 kg condition for both the step rate and double support percentage. There was no change between modes for step rate standard deviation. For overground compared to treadmill walking, standard deviation for stride length and double support percentage increased and decreased, respectively. Changes in the load of up to 40 kg, inclination of 6% grade away from the level (i.e., uphill or downhill) and mode (treadmill and overground) produced small, yet statistically significant changes in spatiotemporal parameters. Variability, as assessed by standard deviation, was not systematically lower during treadmill walking compared to overground walking. Due to the small magnitude of changes, treadmill walking appears to replicate the spatiotemporal parameters of overground walking. PMID:28149338

  13. Odds per adjusted standard deviation: comparing strengths of associations for risk factors measured on different scales and across diseases and populations.

    PubMed

    Hopper, John L

    2015-11-15

    How can the "strengths" of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors-and that is how risk gradients are interpreted-so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RR(s). This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. The two errors of using the within-subject standard deviation (WSD) as the standard error of a reliable change index.

    PubMed

    Maassen, Gerard H

    2010-08-01

    In this Journal, Lewis and colleagues introduced a new Reliable Change Index (RCI(WSD)), which incorporated the within-subject standard deviation (WSD) of a repeated measurement design as the standard error. In this note, two opposite errors in using WSD this way are demonstrated. First, being the standard error of measurement of only a single assessment makes WSD too small when practice effects are absent. Then, too many individuals will be designated reliably changed. Second, WSD can grow unlimitedly to the extent that differential practice effects occur. This can even make RCI(WSD) unable to detect any reliable change.

  15. Gender Differences in Numeracy in Indonesia: Evidence from a Longitudinal Dataset

    ERIC Educational Resources Information Center

    Suryadarma, Daniel

    2015-01-01

    This paper uses a rich longitudinal dataset to measure the evolution of the gender differences in numeracy among school-age children in Indonesia. Girls outperformed boys by 0.08 standard deviations when the sample was around 11 years old. Seven years later, the gap has widened to 0.19 standard deviations, equivalent to around 18 months of…

  16. A Survey Data Response to the Teaching of Utility Curves and Risk Aversion

    ERIC Educational Resources Information Center

    Hobbs, Jeffrey; Sharma, Vivek

    2011-01-01

    In many finance and economics courses as well as in practice, the concept of risk aversion is reduced to the standard deviation of returns, whereby risk-averse investors prefer to minimize their portfolios' standard deviations. In reality, the concept of risk aversion is richer and more interesting than this, and can easily be conveyed through…

  17. On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution

    ERIC Educational Resources Information Center

    Wagenmakers, Eric-Jan; Brown, Scott

    2007-01-01

    Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…

  18. A novel sorbent based on carbon nanotube/amino-functionalized sol-gel for the headspace solid-phase microextraction of α-bisabolol from medicinal plant samples using experimental design.

    PubMed

    Yarazavi, Mina; Noroozian, Ebrahim

    2018-02-13

    A novel sol-gel coating on a stainless-steel fiber was developed for the first time for the headspace solid-phase microextraction and determination of α-bisabolol with gas chromatography and flame ionization detection. The parameters influencing the efficiency of solid-phase microextraction process, such as extraction time and temperature, pH, and ionic strength, were optimized by the experimental design method. Under optimized conditions, the linear range was between 0.0027 and 100 μg/mL. The relative standard deviations determined at 0.01 and 1.0 μg/mL concentration levels (n = 3), respectively, were as follows: intraday relative standard deviations 3.4 and 3.3%; interday relative standard deviations 5.0 and 4.3%; and fiber-to-fiber relative standard deviations 6.0 and 3.5%. The relative recovery values were 90.3 and 101.4% at 0.01 and 1.0 μg/mL spiking levels, respectively. The proposed method was successfully applied to various real samples containing α-bisabolol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Results of an interlaboratory method performance study for the size determination and quantification of silver nanoparticles in chicken meat by single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS).

    PubMed

    Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J

    2017-08-01

    Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.

  20. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups

    PubMed Central

    Bala, Madhu; Goyal, Virender

    2014-01-01

    ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005

  1. MMIC linear-phase and digital modulators for deep space spacecraft X-band transponder applications

    NASA Technical Reports Server (NTRS)

    Mysoor, Narayan R.; Ali, Fazal

    1991-01-01

    The design concepts, analyses, and development of GaAs monolithic microwave integrated circuit (MMIC) linear-phase and digital modulators for the next generation of space-borne communications systems are summarized. The design approach uses a compact lumped element quadrature hybrid and Metal Semiconductor Field Effect Transistors (MESFET)-varactors to provide low loss and well-controlled phase performance for deep space transponder (DST) applications. The measured results of the MESFET-diode show a capacitance range of 2:1 under reverse bias, and a Q of 38 at 10 GHz. Three cascaded sections of hybrid-coupled reflection phase shifters were modeled and simulations performed to provide an X-band (8415 +/- 50 MHz) DST phase modulator with +/- 2.5 radians of peak phase deviation. The modulator will accommodate downlink signal modulation with composite telemetry and ranging data, with a deviation linearity tolerance of +/- 8 percent and insertion loss of less than 8 +/- 0.5 dB. The MMIC digital modulator is designed to provide greater than 10 Mb/s of bi-phase modulation at X-band.

  2. Development and operation of a quality assurance system for deviations from standard operating procedures in a clinical cell therapy laboratory.

    PubMed

    McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J

    2003-01-01

    Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in need of such a program.

  3. A 1.3-μm four-channel directly modulated laser array fabricated by SAG-Upper-SCH technology

    NASA Astrophysics Data System (ADS)

    Guo, Fei; Lu, Dan; Zhang, Ruikang; Liu, Songtao; Sun, Mengdie; Kan, Qiang; Ji, Chen

    2017-01-01

    A monolithically integrated four-channel directly modulated laser (DML) array working at the 1.3-μm band is demonstrated. The laser was manufactured by using the techniques of selective area growth (SAG) of the upper separate confinement heterostructure (Upper-SCH) and modified butt-joint method. The fabricated device showed stable single mode operation with the side mode suppression ratio (SMSR) >35 dB, and high wavelength accuracy with the deviations from the linear fitted values <±0.03 nm for all channels. Furthermore, small signal modulation bandwidth >7 GHz was obtained, which may be suitable for 40 GbE applications in the 1.3-μm band.

  4. Lightweight 3.66-meter-diameter conical mesh antenna reflector

    NASA Technical Reports Server (NTRS)

    Moore, D. M.

    1974-01-01

    A description is given of a 3.66 m diameter nonfurlable conical mesh antenna incorporating the line source feed principle recently developed. The weight of the mesh reflector and its support structure is 162 N. An area weighted RMS surface deviation of 0.28 mm was obtained. The RF performance measurements show a gain of 48.3 db at 8.448 GHz corresponding to an efficiency of 66%. During the design and development of this antenna, the technology for fabricating the large conical membranes of knitted mesh was developed. As part of this technology a FORTRAN computer program, COMESH, was developed which permits the user to predict the surface accuracy of a stretched conical membrane.

  5. An integrated multichannel neural recording analog front-end ASIC with area-efficient driven right leg circuit.

    PubMed

    Tao Tang; Wang Ling Goh; Lei Yao; Jia Hao Cheong; Yuan Gao

    2017-07-01

    This paper describes an integrated multichannel neural recording analog front end (AFE) with a novel area-efficient driven right leg (DRL) circuit to improve the system common mode rejection ratio (CMRR). The proposed AFE consists of an AC-coupled low-noise programmable-gain amplifier, an area-efficient DRL block and a 10-bit SAR ADC. Compared to conventional DRL circuit, the proposed capacitor-less DRL design achieves 90% chip area reduction with enhanced CMRR performance, making it ideal for multichannel biomedical recording applications. The AFE circuit has been designed in a standard 0.18-μm CMOS process. Post-layout simulation results show that the AFE provides two gain settings of 54dB/60dB while consuming 1 μA per channel under a supply voltage of 1 V. The input-referred noise of the AFE integrated from 1 Hz to 10k Hz is only 4 μVrms and the CMRR is 110 dB.

  6. Joint OSNR monitoring and modulation format identification in digital coherent receivers using deep neural networks.

    PubMed

    Khan, Faisal Nadeem; Zhong, Kangping; Zhou, Xian; Al-Arashi, Waled Hussein; Yu, Changyuan; Lu, Chao; Lau, Alan Pak Tao

    2017-07-24

    We experimentally demonstrate the use of deep neural networks (DNNs) in combination with signals' amplitude histograms (AHs) for simultaneous optical signal-to-noise ratio (OSNR) monitoring and modulation format identification (MFI) in digital coherent receivers. The proposed technique automatically extracts OSNR and modulation format dependent features of AHs, obtained after constant modulus algorithm (CMA) equalization, and exploits them for the joint estimation of these parameters. Experimental results for 112 Gbps polarization-multiplexed (PM) quadrature phase-shift keying (QPSK), 112 Gbps PM 16 quadrature amplitude modulation (16-QAM), and 240 Gbps PM 64-QAM signals demonstrate OSNR monitoring with mean estimation errors of 1.2 dB, 0.4 dB, and 1 dB, respectively. Similarly, the results for MFI show 100% identification accuracy for all three modulation formats. The proposed technique applies deep machine learning algorithms inside standard digital coherent receiver and does not require any additional hardware. Therefore, it is attractive for cost-effective multi-parameter estimation in next-generation elastic optical networks (EONs).

  7. Constructing a Graph Database for Semantic Literature-Based Discovery.

    PubMed

    Hristovski, Dimitar; Kastrin, Andrej; Dinevski, Dejan; Rindflesch, Thomas C

    2015-01-01

    Literature-based discovery (LBD) generates discoveries, or hypotheses, by combining what is already known in the literature. Potential discoveries have the form of relations between biomedical concepts; for example, a drug may be determined to treat a disease other than the one for which it was intended. LBD views the knowledge in a domain as a network; a set of concepts along with the relations between them. As a starting point, we used SemMedDB, a database of semantic relations between biomedical concepts extracted with SemRep from Medline. SemMedDB is distributed as a MySQL relational database, which has some problems when dealing with network data. We transformed and uploaded SemMedDB into the Neo4j graph database, and implemented the basic LBD discovery algorithms with the Cypher query language. We conclude that storing the data needed for semantic LBD is more natural in a graph database. Also, implementing LBD discovery algorithms is conceptually simpler with a graph query language when compared with standard SQL.

  8. A Golay complementary TS-based symbol synchronization scheme in variable rate LDPC-coded MB-OFDM UWBoF system

    NASA Astrophysics Data System (ADS)

    He, Jing; Wen, Xuejie; Chen, Ming; Chen, Lin

    2015-09-01

    In this paper, a Golay complementary training sequence (TS)-based symbol synchronization scheme is proposed and experimentally demonstrated in multiband orthogonal frequency division multiplexing (MB-OFDM) ultra-wideband over fiber (UWBoF) system with a variable rate low-density parity-check (LDPC) code. Meanwhile, the coding gain and spectral efficiency in the variable rate LDPC-coded MB-OFDM UWBoF system are investigated. By utilizing the non-periodic auto-correlation property of the Golay complementary pair, the start point of LDPC-coded MB-OFDM UWB signal can be estimated accurately. After 100 km standard single-mode fiber (SSMF) transmission, at the bit error rate of 1×10-3, the experimental results show that the short block length 64QAM-LDPC coding provides a coding gain of 4.5 dB, 3.8 dB and 2.9 dB for a code rate of 62.5%, 75% and 87.5%, respectively.

  9. On the Use of 3dB Qualification Margin for Structural Parts on Expendable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Yunis, Isam

    2007-01-01

    The standard random vibration qualification test used for Expendable Launch Vehicle components is Maximum Predicted Environment (MPE) + 6dB for a duration of 4 times the service life of the part. This can be a severe qualification test for these fatigue-sensitive structures. This paper uses flight data from several launch vehicles to establish that reducing the qualification approach to MPE+3dB for the duration of the peak environment (1x life) is valid for fatigue-sensitive structural components. Items that can be classified as fatigue-sensitive are probes, ducts, tubing, bellows, hoses, and any non-functional structure. Non-functional structure may be flight critical or carry fluid, but it cannot include any moving parts or electronics. This reduced qualification approach does not include primary or secondary structure which would be exclusively designed by peak loads, either transient or quasi-static, that are so large and of so few cycles as to make fatigue a moot point.

  10. The ConSurf-DB: pre-calculated evolutionary conservation profiles of protein structures.

    PubMed

    Goldenberg, Ofir; Erez, Elana; Nimrod, Guy; Ben-Tal, Nir

    2009-01-01

    ConSurf-DB is a repository for evolutionary conservation analysis of the proteins of known structures in the Protein Data Bank (PDB). Sequence homologues of each of the PDB entries were collected and aligned using standard methods. The evolutionary conservation of each amino acid position in the alignment was calculated using the Rate4Site algorithm, implemented in the ConSurf web server. The algorithm takes into account the phylogenetic relations between the aligned proteins and the stochastic nature of the evolutionary process explicitly. Rate4Site assigns a conservation level for each position in the multiple sequence alignment using an empirical Bayesian inference. Visual inspection of the conservation patterns on the 3D structure often enables the identification of key residues that comprise the functionally important regions of the protein. The repository is updated with the latest PDB entries on a monthly basis and will be rebuilt annually. ConSurf-DB is available online at http://consurfdb.tau.ac.il/

  11. The ConSurf-DB: pre-calculated evolutionary conservation profiles of protein structures

    PubMed Central

    Goldenberg, Ofir; Erez, Elana; Nimrod, Guy; Ben-Tal, Nir

    2009-01-01

    ConSurf-DB is a repository for evolutionary conservation analysis of the proteins of known structures in the Protein Data Bank (PDB). Sequence homologues of each of the PDB entries were collected and aligned using standard methods. The evolutionary conservation of each amino acid position in the alignment was calculated using the Rate4Site algorithm, implemented in the ConSurf web server. The algorithm takes into account the phylogenetic relations between the aligned proteins and the stochastic nature of the evolutionary process explicitly. Rate4Site assigns a conservation level for each position in the multiple sequence alignment using an empirical Bayesian inference. Visual inspection of the conservation patterns on the 3D structure often enables the identification of key residues that comprise the functionally important regions of the protein. The repository is updated with the latest PDB entries on a monthly basis and will be rebuilt annually. ConSurf-DB is available online at http://consurfdb.tau.ac.il/ PMID:18971256

  12. Ku-band radar threshold analysis

    NASA Technical Reports Server (NTRS)

    Weber, C. L.; Polydoros, A.

    1979-01-01

    The statistics of the CFAR threshold for the Ku-band radar was determined. Exact analytical results were developed for both the mean and standard deviations in the designated search mode. The mean value is compared to the results of a previously reported simulation. The analytical results are more optimistic than the simulation results, for which no explanation is offered. The normalized standard deviation is shown to be very sensitive to signal-to-noise ratio and very insensitive to the noise correlation present in the range gates of the designated search mode. The substantial variation in the CFAR threshold is dominant at large values of SNR where the normalized standard deviation is greater than 0.3. Whether or not this significantly affects the resulting probability of detection is a matter which deserves additional attention.

  13. Standard deviation analysis of the mastoid fossa temperature differential reading: a potential model for objective chiropractic assessment.

    PubMed

    Hart, John

    2011-03-01

    This study describes a model for statistically analyzing follow-up numeric-based chiropractic spinal assessments for an individual patient based on his or her own baseline. Ten mastoid fossa temperature differential readings (MFTD) obtained from a chiropractic patient were used in the study. The first eight readings served as baseline and were compared to post-adjustment readings. One of the two post-adjustment MFTD readings fell outside two standard deviations of the baseline mean and therefore theoretically represents improvement according to pattern analysis theory. This study showed how standard deviation analysis may be used to identify future outliers for an individual patient based on his or her own baseline data. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  14. Effects of Random Shadings, Phasing Errors, and Element Failures on the Beam Patterns of Linear and Planar Arrays

    DTIC Science & Technology

    1980-03-14

    failure Sigmar (Or) in line 50, the standard deviation of the relative error of the weights Sigmap (o) in line 60, the standard deviation of the phase...200, the weight structures in the x and y coordinates Q in line 210, the probability of element failure Sigmar (Or) in line 220, the standard...NUMBER OF ELEMENTS =u;2*H 120 PRINT "Pr’obability of elemenit failure al;O 130 PRINT "Standard dtvi&t ion’ oe r.1&tive ýrror of wl; Sigmar 14 0 PRINT

  15. SU-E-I-59: Investigation of the Usefulness of a Standard Deviation and Mammary Gland Density as Indexes for Mammogram Classification.

    PubMed

    Takarabe, S; Yabuuchi, H; Morishita, J

    2012-06-01

    To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.

  16. Flexible CMOS low-noise amplifiers for beyond-3G wireless hand-held devices

    NASA Astrophysics Data System (ADS)

    Becerra-Alvarez, Edwin C.; Sandoval-Ibarra, Federico; de la Rosa, José M.

    2009-05-01

    This paper explores the use of reconfigurable Low-Noise Amplifiers (LNAs) for the implementation of CMOS Radio Frequency (RF) front-ends in the next generation of multi-standard wireless transceivers. Main circuit strategies reported so far for multi-standard LNAs are reviewed and a novel flexible LNA intended for Beyond-3G RF hand-held terminals is presented. The proposed LNA circuit consists of a two-stage topology that combines inductive-source degeneration with PMOS-varactor based tuning network and a programmable load to adapt its performance to different standard specifications without penalizing the circuit noise and with a reduced number of inductors as compared to previous reported reconfigurable LNAs. The circuit has been designed in a 90-nm CMOS technology to cope with the requirements of the GSM, WCDMA, Bluetooth and WLAN (IEEE 802.11b-g) standards. Simulation results, including technology and packaging parasitics, demonstrate correct operation of the circuit for all the standards under study, featuring NF<2.8dB, S21>13.3dB and IIP3>10.9dBm, over a 1.85GHz-2.4GHz band, with an adaptive power consumption between 17mW and 22mW from a 1-V supply voltage. Preliminary experimental measurements are included, showing a correct reconfiguration operation within the operation band.

  17. 40 CFR 63.7951 - What reports must I submit and when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the information in § 63.10(d)(5)(i). (5) If there were no deviations from any emissions limitations... that there were no deviations from the emissions limitations, work practice standards, or operation and...) For each deviation from an emissions limitation (including an operating limit) that occurs at an...

  18. Breathing exercises for dysfunctional breathing/hyperventilation syndrome in adults.

    PubMed

    Jones, Mandy; Harvey, Alex; Marston, Louise; O'Connell, Neil E

    2013-05-31

    Dysfunctional breathing/hyperventilation syndrome (DB/HVS) is a respiratory disorder, psychologically or physiologically based, involving breathing too deeply and/or too rapidly (hyperventilation) or erratic breathing interspersed with breath-holding or sighing (DB). DB/HVS can result in significant patient morbidity and an array of symptoms including breathlessness, chest tightness, dizziness, tremor and paraesthesia. DB/HVS has an estimated prevalence of 9.5% in the general adult population, however, there is little consensus regarding the most effective management of this patient group. (1) To determine whether breathing exercises in patients with DB/HVS have beneficial effects as measured by quality of life indices (2) To determine whether there are any adverse effects of breathing exercises in patients with DB/HVS SEARCH METHODS: We identified trials for consideration using both electronic and manual search strategies. We searched CENTRAL, MEDLINE, EMBASE, and four other databases. The latest search was in February 2013. We planned to include randomised, quasi-randomised or cluster randomised controlled trials (RCTs) in which breathing exercises, or a combined intervention including breathing exercises as a key component, were compared with either no treatment or another therapy that did not include breathing exercises in patients with DB/HVS. Observational studies, case studies and studies utilising a cross-over design were not eligible for inclusion.We considered any type of breathing exercise for inclusion in this review, such as breathing control, diaphragmatic breathing, yoga breathing, Buteyko breathing, biofeedback-guided breathing modification, yawn/sigh suppression. Programs where exercises were either supervised or unsupervised were eligible as were relaxation techniques and acute-episode management, as long as it was clear that breathing exercises were a key component of the intervention.We excluded any intervention without breathing exercises or where breathing exercises were not key to the intervention. Two review authors independently checked search results for eligible studies, assessed all studies that appeared to meet the selection criteria and extracted data. We used standard procedures recommended by The Cochrane Collaboration. We included a single RCT assessed at unclear risk of bias, which compared relaxation therapy (n = 15) versus relaxation therapy and breathing exercises (n = 15) and a no therapy control group (n = 15).Quality of life was not an outcome measure in this RCT, and no numerical data or statistical analysis were presented in this paper. A significant reduction in the frequency and severity of hyperventilation attacks in the breathing exercise group compared with the control group was reported. In addition, a significant difference in frequency and severity of hyperventilation attacks between the breathing and relaxation group was reported. However, no information could be extracted from the paper regarding the size of the treatment effects. The results of this systematic review are unable to inform clinical practice, based on the inclusion of only one small, poorly reported RCT. There is no credible evidence regarding the effectiveness of breathing exercises for the clinical symptoms of DB/HVS. It is currently unknown whether these interventions offer any added value in this patient group or whether specific types of breathing exercise demonstrate superiority over others. Given that breathing exercises are frequently used to treat DB/HVS, there is an urgent need for further well designed clinical trials in this area. Future trials should conform to the CONSORT statement for standards of reporting and use appropriate, validated outcome measures. Trial reports should also ensure full disclosure of data for all important clinical outcomes.

  19. MO-F-CAMPUS-T-03: Data Driven Approaches for Determination of Treatment Table Tolerance Values for Record and Verification Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, N; DiCostanzo, D; Fullenkamp, M

    2015-06-15

    Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations weremore » computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.« less

  20. A low power, low noise Programmable Analog Front End (PAFE) for biopotential measurements.

    PubMed

    Adimulam, Mahesh Kumar; Divya, A; Tejaswi, K; Srinivas, M B

    2017-07-01

    A low power Programmable Analog Front End (PAFE) for biopotential measurements is presented in this paper. The PAFE circuit processes electrocardiogram (ECG), electromyography (EMG) and electroencephalogram (EEG) signals with higher accuracy. It consists mainly of improved transconductance programmable gain instrumentational amplifier (PGIA), programmable high pass filter (PHPF), and second order low pass filter (SLPF). A 15-bit programmable 5-stage successive approximation analog-to-digital converter (SAR-ADC) is implemented for improving the performance, whose power consumption is reduced due to multiple stages and by OTA/Comparator sharing technique between the stages. The power consumption is further reduced by operating the analog portion of PAFE on 0.5V supply voltage and digital portion on 0.3V supply voltage generated internally through a voltage regulator. The proposed low power PAFE has been fabricated in 180nm standard CMOS process. The performance parameters of PAFE in 15-bit mode are found to be, gain of 31-70 dB, input referred noise of 1.15 μVrms, CMRR of 110 dB, PSRR of 104 dB, and signal-to-noise distortion ratio (SNDR) of 83.5dB. The power consumption of the design is 1.1 μW @ 0.5 V supply voltage and it occupies a core silicon area of 1.2 mm 2 .

  1. Association of Behavior With Noise-Induced Hearing Loss Among Attendees of an Outdoor Music Festival: A Secondary Analysis of a Randomized Clinical Trial.

    PubMed

    Kraaijenga, Véronique J C; van Munster, J J C M; van Zanten, G A

    2018-06-01

    To date, factors associated with noise-induced hearing loss at music festivals have not yet been analyzed in a single comprehensive data set. In addition, little is known about the hearing loss-associated behavior of music festival attendees. To assess which factors are associated with the occurrence of a temporary threshold shift (TTS) after music exposure and to investigate the behavior of music festival attendees. This prospective post hoc analysis gathered data from a randomized, single-blind clinical trial conducted on September 5, 2015, at an outdoor music festival in Amsterdam, the Netherlands. Adult volunteers with normal hearing were recruited via social media from August 26 through September 3, 2015. Intention to use earplugs was an exclusion criterion. Of 86 volunteers assessed, 51 were included. This post hoc analysis was performed from October 3, 2016, through February 27, 2017. Music festival visit for 4.5 hours. The primary outcome was a TTS on a standard audiogram for the frequencies 3.0- and 4.0-kHz. Multivariable linear regression was performed to determine which factors are associated with a TTS. A questionnaire on behavior, hearing, and tinnitus was distributed to the participants before and after the festival visit. A total of 51 participants were included (18 men [35%] and 33 women [65%]) with a mean (SD) age of 27 (6) years. Mean (SD) threshold change across 3.0 and 4.0 kHz was 5.4 (5.7) dB for the right ear and 4.0 (6.1) dB for the left ear. Earplug use (absolute difference in the left ear, -6.0 dB [95% CI, -8.7 to -3.2 dB]; in the right ear, -6.4 dB [95% CI, -8.8 to -4.1 dB]), quantity of alcohol use (absolute difference per unit in the left ear, 1.1 dB [95% CI, 0.5 to 1.7 dB]; in the right ear, 0.7 dB [95% CI, 0.1 to 1.4 dB]), drug use (absolute difference in the right ear, 6.0 dB [95% CI, 0.9 to 11.1 dB]), and male sex (absolute difference in the right ear, 4.1 dB [95% CI, 0.3 to 5.9 dB]) were independently associated with hearing loss, with earplug use being the most important factor. Unprotected participants reported significantly worse subjective hearing performance and tinnitus after the festival visit than did participants using earplugs (Cramer V, 0.62 [95% CI, 0.47-0.79] and 0.39 [95% CI, 0.16-0.62], respectively). In the earplug group, the perceived loudness (r = -0.72; 95% CI, -1.00 to -0.43) and appreciation (r = 0.53; 95% CI, 0.29 to 0.78) of music and speech perception (r = 0.21; 95% CI, 0.09 to 0.35) were correlated with the duration of earplug use. The present study identified nonuse of earplugs, use of alcohol and drugs, and male sex as associated with a TTS at an outdoor music festival. Physicians should consider these factors to raise awareness about the combined risk of attending music festivals without using earplugs while consuming alcohol and/or drugs. The intention to use earplugs was correlated with the loudness and appreciation of music with earplugs, which may advocate for the use of personalized earplugs. trialregister.nl Identifier: NTR5401.

  2. Evidence for the associated production of the Higgs boson and a top quark pair with the ATLAS detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaboud, M.; Aad, G.; Abbott, B.

    Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less

  3. Evidence for the associated production of the Higgs boson and a top quark pair with the ATLAS detector

    DOE PAGES

    Aaboud, M.; Aad, G.; Abbott, B.; ...

    2018-04-09

    Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less

  4. Evidence for the associated production of the Higgs boson and a top quark pair with the ATLAS detector

    NASA Astrophysics Data System (ADS)

    Aaboud, M.; Aad, G.; Abbott, B.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; Abouzeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Afik, Y.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Alconada Verzini, M. J.; Alderweireldt, S. C.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allaire, C.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M. I.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amadio, B. T.; Amaral Coutinho, Y.; Ambroz, L.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amoroso, S.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Araujo Ferraz, V.; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkin, R. J.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Avramidou, R.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Bagnaia, P.; Bahmani, M.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Bakker, P. J.; Bakshi Gupta, D.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Bandyopadhyay, A.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barkeloo, J. T.; Barklow, T.; Barlow, N.; Barnea, R.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barranco Navarro, L.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bauer, K. T.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Beck, H. C.; Becker, K.; Becker, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behera, A.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Bergsten, L. J.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertram, I. A.; Bertsche, C.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Bethani, A.; Bethke, S.; Betti, A.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Bierwagen, K.; Biesuz, N. V.; Biglietti, M.; Billoud, T. R. V.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blumenschein, U.; Blunier, Dr.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Bonilla, J. S.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Bossio Sola, J. D.; Boudreau, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozson, A. J.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Braren, F.; Bratzler, U.; Brau, B.; Brau, J. E.; Breaden Madden, W. D.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brost, E.; Broughton, J. H.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Bruno, S.; Brunt, Bh; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Büscher, D.; Büscher, V.; Buschmann, E.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Cabras, G.; Cabrera Urbán, S.; Caforio, D.; Cai, H.; Cairo, V. M. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Calvente Lopez, S.; Calvet, D.; Calvet, S.; Calvet, T. P.; Camacho Toro, R.; Camarda, S.; Camarri, P.; Cameron, D.; Caminal Armadans, R.; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Cano Bret, M.; Cantero, J.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Casadei, D.; Casado, M. P.; Casha, A. F.; Casolino, M.; Casper, D. W.; Castelijn, R.; Castillo Gimenez, V.; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Cerda Alberich, L.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Che, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, C.; Chen, H.; Chen, J.; Chen, J.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, Y. S.; Christodoulou, V.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Cinca, D.; Cindro, V.; Cioarǎ, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Clark, A.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corrigan, E. E.; Corriveau, F.; Cortes-Gonzalez, A.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Cuhadar Donszelmann, T.; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czekierda, S.; Czodrowski, P.; D'Amen, G.; D'Auria, S.; D'Eramo, L.; D'Onofrio, M.; da Cunha Sargedas de Sousa, M. J.; da Via, C.; Dabrowski, W.; Dado, T.; Dahbi, S.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Dann, N. S.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; de, K.; de Asmundis, R.; de Benedetti, A.; de Castro, S.; de Cecco, S.; de Groot, N.; de Jong, P.; de la Torre, H.; de Lorenzi, F.; de Maria, A.; de Pedis, D.; de Salvo, A.; de Sanctis, U.; de Santo, A.; de Vasconcelos Corga, K.; de Vivie de Regie, J. B.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Della Pietra, M.; Della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; Demarco, D. A.; Demers, S.; Demichev, M.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; di Bello, F. A.; di Ciaccio, A.; di Ciaccio, L.; di Clemente, W. K.; di Donato, C.; di Girolamo, A.; di Micco, B.; di Nardo, R.; di Petrillo, K. F.; di Simone, A.; di Sipio, R.; di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Dickinson, J.; Diehl, E. B.; Dietrich, J.; Díez Cornell, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; Do Vale, M. A. B.; Dobre, M.; Dodsworth, D.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dreyer, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubinin, F.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dulsen, C.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Duperrin, A.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Duvnjak, D.; Dyndal, M.; Dziedzic, B. S.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Ennis, J. S.; Epland, M. B.; Erdmann, J.; Ereditato, A.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Estrada Pastor, O.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Fabiani, V.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Faucci Giannelli, M.; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feickert, M.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, M.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Fernandez Martinez, P.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Flores, L. M.; Flores Castillo, L. R.; Fomin, N.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Freund, W. S.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Garay Walls, F. M.; García, C.; García Navarro, J. E.; García Pascual, J. A.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gasnikova, K.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giangiacomi, N.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugliarelli, G.; Giugni, D.; Giuli, F.; Giulini, M.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Gama, R.; Gonella, G.; Gonella, L.; Gongadze, A.; Gonnella, F.; Gonski, J. L.; González de La Hoz, S.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Goy, C.; Gozani, E.; Grabowska-Bold, I.; Gradin, P. O. J.; Graham, E. C.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guerguichon, A.; Guescini, F.; Guest, D.; Gueta, O.; Gugel, R.; Gui, B.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gurbuz, S.; Gustavino, G.; Gutelman, B. J.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Han, K.; Han, L.; Han, S.; Hanagaki, K.; Hance, M.; Handl, D. M.; Haney, B.; Hankache, R.; Hanke, P.; Hansen, E.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Harkusha, S.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heer, S.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Henriques Correia, A. M.; Herbert, G. H.; Herde, H.; Herget, V.; Hernández Jiménez, Y.; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hildebrand, K.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hlaluku, D. R.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Hohov, D.; Holmes, T. R.; Holzbock, M.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Horyn, L. A.; Hostachy, J.-Y.; Hostiuc, A.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Huhtinen, M.; Hunter, R. F. H.; Huo, P.; Hupe, A. M.; Huseynov, N.; Huston, J.; Huth, J.; Hyneman, R.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iguchi, R.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Iliadis, D.; Ilic, N.; Iltzsche, F.; Introzzi, G.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Iturbe Ponce, J. M.; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakel, G.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javå¯Rek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Junggeburth, J. J.; Juste Rozas, A.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanjir, L.; Kano, Y.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kellermann, E.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-Zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kiehn, M.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Klitzner, F. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Konya, B.; Kopeliansky, R.; Koperny, S.; Korcyl, K.; Kordas, K.; Korn, A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; La Ruffa, F.; Lacasta, C.; Lacava, F.; Lacey, J.; Lack, D. P. J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Lau, T. S.; Laudrain, A.; Law, A. T.; Laycock, P.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; Leblanc, M.; Lecompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehmann Miotto, G.; Leight, W. A.; Leisos, A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Les, R.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, C.-Q.; Li, H.; Li, L.; Li, Q.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Limosani, A.; Lin, C. Y.; Lin, K.; Lin, S. C.; Lin, T. H.; Linck, R. A.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J. B.; Liu, K.; Liu, M.; Liu, P.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo, C. Y.; Lo Sterzo, F.; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Lopez Paz, I.; Lopez Solis, A.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lund-Jensen, B.; Lutz, M. S.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyu, F.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; MacDonald, C. M.; Maček, B.; Machado Miguens, J.; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Madysa, N.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magerl, V.; Maidantchik, C.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandić, I.; Maneira, J.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J.; Mankinen, K. H.; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marin Tobon, C. A.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; Martin Dit Latour, B.; Martinez, M.; Martinez Outschoorn, V. I.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Mason, L. H.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; Mc Fadden, N. C.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; McFayden, J. A.; McHedlidze, G.; McKay, M. A.; McMahon, S. J.; McNamara, P. C.; McNicol, C. J.; McPherson, R. A.; Meadows, Z. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Mellado Garcia, B. R.; Mellenthin, J. D.; Melo, M.; Meloni, F.; Melzer, A.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Merlassino, C.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Meyer Zu Theenhausen, H.; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Millar, D. A.; Miller, D. W.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mirto, A.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, M.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Munoz Sanchez, F. J.; Murin, P.; Murray, W. J.; Murrone, A.; Muškinja, M.; Mwewa, C.; Myagkov, A. G.; Myers, J.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Naranjo Garcia, R. F.; Narayan, R.; Narrias Villar, D. I.; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Ng, Y. S.; Nguyen Manh, T.; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikiforou, N.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nitta, T.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Novotny, R.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'Connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Ojeda, M. L.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Oleiro Seabra, L. F.; Olivares Pino, S. A.; Oliveira Damazio, D.; Oliver, J. L.; Olsson, M. J. R.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oppen, H.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orgill, E. C.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero Y Garzon, G.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Pacheco Rodriguez, L.; Padilla Aranda, C.; Pagan Griso, S.; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parida, B.; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Peri, F.; Perini, L.; Pernegger, H.; Perrella, S.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Pham, T.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pinamonti, M.; Pinfold, J. L.; Pitt, M.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pogrebnyak, I.; Pohl, D.; Pokharel, I.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Ponomarenko, D.; Pontecorvo, L.; Popeneciu, G. A.; Portillo Quintero, D. M.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potti, H.; Poulsen, T.; Poveda, J.; Pozo Astigarraga, M. E.; Pralavorio, P.; Prell, S.; Price, D.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Qureshi, A.; Radeka, V.; Radhakrishnan, S. K.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rivera Vergara, J. C.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Rodriguez Bosca, S.; Rodriguez Perez, A.; Rodriguez Rodriguez, D.; Rodríguez Vera, A. M.; Roe, S.; Rogan, C. S.; Røhne, O.; Röhrig, R.; Roloff, J.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rossini, L.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Roy, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Rüttinger, E. M.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Salamanna, G.; Salazar Loyola, J. E.; Salek, D.; Sales de Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Sanchez Pineda, A.; Sandaker, H.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santos, H.; Santoyo Castillo, I.; Sapronov, A.; Saraiva, J. G.; Sasaki, O.; Sato, K.; Sauvan, E.; Savard, P.; Savic, N.; Sawada, R.; Sawyer, C.; Sawyer, L.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaeffer, J.; Schaepe, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Schegelsky, V. A.; Scheirich, D.; Schenck, F.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillaci, Z. M.; Schillo, C.; Schioppa, E. J.; Schioppa, M.; Schleicher, K. E.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultz-Coulon, H.-C.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scornajenghi, M.; Scuri, F.; Scutti, F.; Scyboz, L. M.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Severini, H.; Šfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shahinian, J. D.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Sharma, A. S.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherman, A. D.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sideras Haddad, E.; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silva, M.; Silverstein, S. B.; Simic, L.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffa, A. M.; Soffer, A.; Søgaard, A.; Soh, D. A.; Sokhrannyi, G.; Solans Sanchez, C. A.; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Song, W.; Sopczak, A.; Sopkova, F.; Sosa, D.; Sotiropoulou, C. L.; Sottocornola, S.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; St. Denis, R. D.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Stegler, M.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, T. J.; Stewart, G. A.; Stockton, M. C.; Stoicea, G.; Stolte, P.; Stonjek, S.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, D. M. S.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sydorenko, A.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Tahirovic, E.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeda, K.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanioka, R.; Tannenwald, B. B.; Tapia Araya, S.; Tapprogge, S.; Tarek Abouelfadl Mohamed, A. T.; Tarem, S.; Tarna, G.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, A. C.; Taylor, A. J.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Thais, S. J.; Theveneaux-Pelzer, T.; Thiele, F.; Thomas, J. P.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tian, Y.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Todt, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Turchikhin, S.; Turgeman, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Uno, K.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vadla, K. O. H.; Vaidya, A.; Valderanis, C.; Valdes Santurio, E.; Valente, M.; Valentinetti, S.; Valero, A.; Valéry, L.; Vallier, A.; Valls Ferrer, J. A.; van den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Vazquez Furelos, D.; Vazquez Schroeder, T.; Veatch, J.; Vecchio, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Viaux Maira, N.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von Buddenbrock, S. E.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Wakamiya, K.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, A. M.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.-J.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. M.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Weston, T. D.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, A.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Woods, N. L.; Worm, S. D.; Wosiek, B. K.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Xu, W.; Yabsley, B.; Yacoob, S.; Yajima, K.; Yallup, D. P.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamanaka, T.; Yamane, F.; Yamatani, M.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, S.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhou, Y.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zhulanov, V.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; Zur Nedden, M.; Zwalinski, L.; Atlas Collaboration

    2018-04-01

    A search for the associated production of the Higgs boson with a top quark pair (t t ¯H ) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb-1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy √{s }=13 TeV at the Large Hadron Collider. Higgs boson decays to W W*, τ τ , and Z Z* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the t t ¯H production cross section is σ (t t ¯H )=79 0-210+230 fb , in agreement with the Standard Model prediction of 50 7-50+35 fb . The combination of this result with other t t ¯H searches from the ATLAS experiment using the Higgs boson decay modes to b b ¯, γ γ and Z Z*→4 ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the t t ¯H production mode.

  5. WASP (Write a Scientific Paper) using Excel -5: Quartiles and standard deviation.

    PubMed

    Grech, Victor

    2018-03-01

    The almost inevitable descriptive statistics exercise that is undergone once data collection is complete, prior to inferential statistics, requires the acquisition of basic descriptors which may include standard deviation and quartiles. This paper provides pointers as to how to do this in Microsoft Excel™ and explains the relationship between the two. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Validation Test Report for GDEM4

    DTIC Science & Technology

    2010-08-19

    standard deviations called the Generalized Digital Environmental Model ( GDEM ). The present document describes the development and evaluation of GDEM4...the newest version of GDEM . As part of the evaluation of GDEM4, comparisons are made in this report to GDEM3 and to four other ocean climatologies...depth climatology of temperature and salinity and their standard deviations called the Generalized Digital Environmental Model ( GDEM ). The history of

  7. 40 CFR 91.508 - Cumulative Sum (CumSum) procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... family may be determined to be in noncompliance for purposes of § 91.510. H = The Action Limit. It is 5.0 × σ, and is a function of the standard deviation, σ. σ = is the sample standard deviation and is... Equation must be final deteriorated test results as defined in § 91.509(c). Ci = max[0 0R (Ci-1 + Xi − (FEL...

  8. Modeling the Zeeman effect in high altitude SSMIS channels for numerical weather prediction profiles: comparing a fast model and a line-by-line model

    NASA Astrophysics Data System (ADS)

    Larsson, R.; Milz, M.; Rayer, P.; Saunders, R.; Bell, W.; Booton, A.; Buehler, S. A.; Eriksson, P.; John, V.

    2015-10-01

    We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Same channel, there is 1.2 K in average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Same channel, there is 1.3 K in average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies causing up to ± 7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.

  9. Modeling the Zeeman effect in high-altitude SSMIS channels for numerical weather prediction profiles: comparing a fast model and a line-by-line model

    NASA Astrophysics Data System (ADS)

    Larsson, Richard; Milz, Mathias; Rayer, Peter; Saunders, Roger; Bell, William; Booton, Anna; Buehler, Stefan A.; Eriksson, Patrick; John, Viju O.

    2016-03-01

    We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high-altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Concerning the same channel, there is 1.2 K on average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Regarding the same channel, there is 1.3 K on average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies, causing up to ±7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.

  10. Spectral combination of spherical gravitational curvature boundary-value problems

    NASA Astrophysics Data System (ADS)

    PitoÅák, Martin; Eshagh, Mehdi; Šprlák, Michal; Tenzer, Robert; Novák, Pavel

    2018-04-01

    Four solutions of the spherical gravitational curvature boundary-value problems can be exploited for the determination of the Earth's gravitational potential. In this article we discuss the combination of simulated satellite gravitational curvatures, i.e., components of the third-order gravitational tensor, by merging these solutions using the spectral combination method. For this purpose, integral estimators of biased- and unbiased-types are derived. In numerical studies, we investigate the performance of the developed mathematical models for the gravitational field modelling in the area of Central Europe based on simulated satellite measurements. Firstly, we verify the correctness of the integral estimators for the spectral downward continuation by a closed-loop test. Estimated errors of the combined solution are about eight orders smaller than those from the individual solutions. Secondly, we perform a numerical experiment by considering the Gaussian noise with the standard deviation of 6.5× 10-17 m-1s-2 in the input data at the satellite altitude of 250 km above the mean Earth sphere. This value of standard deviation is equivalent to a signal-to-noise ratio of 10. Superior results with respect to the global geopotential model TIM-r5 are obtained by the spectral downward continuation of the vertical-vertical-vertical component with the standard deviation of 2.104 m2s-2, but the root mean square error is the largest and reaches 9.734 m2s-2. Using the spectral combination of all gravitational curvatures the root mean square error is more than 400 times smaller but the standard deviation reaches 17.234 m2s-2. The combination of more components decreases the root mean square error of the corresponding solutions while the standard deviations of the combined solutions do not improve as compared to the solution from the vertical-vertical-vertical component. The presented method represents a weight mean in the spectral domain that minimizes the root mean square error of the combined solutions and improves standard deviation of the solution based only on the least accurate components.

  11. Host model uncertainties in aerosol radiative forcing estimates: results from the AeroCom Prescribed intercomparison study

    NASA Astrophysics Data System (ADS)

    Stier, P.; Schutgens, N. A. J.; Bellouin, N.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Ma, X.; Myhre, G.; Penner, J. E.; Randles, C. A.; Samset, B.; Schulz, M.; Takemura, T.; Yu, F.; Yu, H.; Zhou, C.

    2013-03-01

    Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as a measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in twelve participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.47 Wm-2 and the inter-model standard deviation is 0.55 Wm-2, corresponding to a relative standard deviation of 12%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.04 Wm-2, and the standard deviation increases to 1.01 W-2, corresponding to a significant relative standard deviation of 97%. However, the top-of-atmosphere forcing variability owing to absorption (subtracting the scattering case from the case with scattering and absorption) is low, with absolute (relative) standard deviations of 0.45 Wm-2 (8%) clear-sky and 0.62 Wm-2 (11%) all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment demonstrates that host model uncertainties could explain about 36% of the overall sulfate forcing diversity of 0.11 Wm-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.

  12. Quantifying the heterogeneity of the tectonic stress field using borehole data

    USGS Publications Warehouse

    Schoenball, Martin; Davatzes, Nicholas C.

    2017-01-01

    The heterogeneity of the tectonic stress field is a fundamental property which influences earthquake dynamics and subsurface engineering. Self-similar scaling of stress heterogeneities is frequently assumed to explain characteristics of earthquakes such as the magnitude-frequency relation. However, observational evidence for such scaling of the stress field heterogeneity is scarce.We analyze the local stress orientations using image logs of two closely spaced boreholes in the Coso Geothermal Field with sub-vertical and deviated trajectories, respectively, each spanning about 2 km in depth. Both the mean and the standard deviation of stress orientation indicators (borehole breakouts, drilling-induced fractures and petal-centerline fractures) determined from each borehole agree to the limit of the resolution of our method although measurements at specific depths may not. We find that the standard deviation in these boreholes strongly depends on the interval length analyzed, generally increasing up to a wellbore log length of about 600 m and constant for longer intervals. We find the same behavior in global data from the World Stress Map. This suggests that the standard deviation of stress indicators characterizes the heterogeneity of the tectonic stress field rather than the quality of the stress measurement. A large standard deviation of a stress measurement might be an expression of strong crustal heterogeneity rather than of an unreliable stress determination. Robust characterization of stress heterogeneity requires logs that sample stress indicators along a representative sample volume of at least 1 km.

  13. [Effect strength variation in the single group pre-post study design: a critical review].

    PubMed

    Maier-Riehle, B; Zwingmann, C

    2000-08-01

    In Germany, studies in rehabilitation research--in particular evaluation studies and examinations of quality of outcome--have so far mostly been executed according to the uncontrolled one-group pre-post design. Assessment of outcome is usually made by comparing the pre- and post-treatment means of the outcome variables. The pre-post differences are checked, and in case of significance, the results are increasingly presented in form of effect sizes. For this reason, this contribution presents different effect size indices used for the one-group pre-post design--in spite of fundamental doubts which exist in relation to that design due to its limited internal validity. The numerator concerning all effect size indices of the one-group pre-post design is defined as difference between the pre- and post-treatment means, whereas there are different possibilities and recommendations with regard to the denominator and hence the standard deviation that serves as the basis for standardizing the difference of the means. Used above all are standardization oriented towards the standard deviation of the pre-treatment scores, standardization oriented towards the pooled standard deviation of the pre- and post-treatment scores, and standardization oriented towards the standard deviation of the pre-post differences. Two examples are given to demonstrate that the different modes of calculating effect size indices in the one-group pre-post design may lead to very different outcome patterns. Additionally, it is pointed out that effect sizes from the uncontrolled one-group pre-post design generally tend to be higher than effect sizes from studies conducted with control groups. Finally, the pros and cons of the different effect size indices are discussed and recommendations are given.

  14. Preparing Students for Success in a Multicultural World: Faculty Advisement and Intercultural Communication.

    ERIC Educational Resources Information Center

    Cornett-DeVito, Myrna M.; Reeves, Kenna J.

    1999-01-01

    Summarizes key findings from counseling, advisement, and intercultural communication literature that are associated with multicultural competence, including the academic and modeling role of the advisor. Offers a conceptual framework of standards for developing multicultural communication advisement competence. (Author/DB)

  15. Coping with the Economic Order through the Big Mac

    ERIC Educational Resources Information Center

    Akenson, James E.

    1977-01-01

    Describes an economic education unit for use in the elementary classroom which employs a case study of McDonalds hamburger chain to teach students about multinational corporations, mass production, standardization, advertising, and capital investment. For journal availability, see SO 505 448. (Author/DB)

  16. Environmental impact of noise levels in and around opencast bauxite mine.

    PubMed

    Kisku, G C; Barman, S C; Kidwai, M M; Bhargava, S K

    2002-01-01

    Until recently, noise pollution has not been paid adequate attention as air, water and land pollution. In order to assess (predict) the impact of bauxite mine noise on employees health and in and around bauxite mine environment, general noise sources and equipment noise were monitored. All these noise sources were compared with prescribed standard noise levels laid down by Central Pollution Control Board (CPCB). Data has also been compared with reference site, north block hill top which is barren and virgin plateau/top covered with grass only and free from human interference. Equipment noise levels were much higher than the other zone of the mine which does not have the corresponding standards. Rock breaker recorded the highest noise level with 73.1 +/- 14.2 to 89.5 +/- 10.1 dB (A) while from ripper dozer it was least with 61.0 +/- 17.3 to 76.2 +/- 6.2 dB (A). Meteorological parameters did not have much influence upon equipment noise up to 100 feet from the source.

  17. Self-assessment of hearing status and risk of noise-induced hearing loss in workers in a rolling stock plant.

    PubMed

    Pawlaczyk-Łuszczyńska, Małgorzata; Dudarewicz, Adam; Zamojska, Małgorzata; Sliwinska-Kowalska, Mariola

    2012-01-01

    Noise measurements and questionnaire inquiries were carried out for 124 workers of a rolling stock plant to develop a hearing conservation program. On the basis of that data, the risk of noise-induced hearing loss (NIHL) was evaluated. Additionally, the workers' hearing ability was assessed with the (modified) Amsterdam inventory for auditory disability and handicap, (m)AIADH. The workers had been exposed to noise at A-weighted daily noise exposure levels of 74-110 dB for 1-40 years. Almost one third of the workers complained of hearing impairment and the (m)AIADH results showed some hearing difficulties in over half of them. The estimated risk of hearing loss over 25 dB in the frequency range of 3-6 kHz was 41-50% when the standard method of predicting NIHL specified in Standard No. ISO 1999:1990 was used. This risk increased to 50-67% when noise impulsiveness, coexposure to organic solvents, elevated blood pressure and smoking were included in calculations.

  18. Use of a Mixture of Surrogates for Infectious Bioagents in a Standard Approach to Assessing Disinfection of Environmental Surfaces ▿

    PubMed Central

    Sabbah, Safaa; Springthorpe, Susan; Sattar, Syed A.

    2010-01-01

    We used a mixture of surrogates (Acinetobacter baumannii, Mycobacterium terrae, hepatitis A virus, and spores of Geobacillus stearothermophilus) for bioagents in a standardized approach to test environmental surface disinfectants. Each carrier containing 10 μl of mixture received 50 μl of a test chemical or saline at 22 ± 2°C. Disinfectant efficacy criteria were ≥6 log10 reduction for the bacteria and the spores and ≥3 log10 reduction for the virus. Peracetic acid (1,000 ppm) was effective in 5 min against the two bacteria and the spores but not against the virus. Chlorine dioxide (CD; 500 and 1,000 ppm) and domestic bleach (DB; 2,500, 3,500, and 5,000 ppm) were effective in 5 min, except for sporicidal activity, which needed 20 min of contact with either 1,000 ppm of CD or the two higher concentrations of DB. PMID:20639366

  19. Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling

    NASA Astrophysics Data System (ADS)

    Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.

    2008-05-01

    We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.

  20. Effect of extreme sea surface temperature events on the demography of an age-structured albatross population.

    PubMed

    Pardo, Deborah; Jenouvrier, Stéphanie; Weimerskirch, Henri; Barbraud, Christophe

    2017-06-19

    Climate changes include concurrent changes in environmental mean, variance and extremes, and it is challenging to understand their respective impact on wild populations, especially when contrasted age-dependent responses to climate occur. We assessed how changes in mean and standard deviation of sea surface temperature (SST), frequency and magnitude of warm SST extreme climatic events (ECE) influenced the stochastic population growth rate log( λ s ) and age structure of a black-browed albatross population. For changes in SST around historical levels observed since 1982, changes in standard deviation had a larger (threefold) and negative impact on log( λ s ) compared to changes in mean. By contrast, the mean had a positive impact on log( λ s ). The historical SST mean was lower than the optimal SST value for which log( λ s ) was maximized. Thus, a larger environmental mean increased the occurrence of SST close to this optimum that buffered the negative effect of ECE. This 'climate safety margin' (i.e. difference between optimal and historical climatic conditions) and the specific shape of the population growth rate response to climate for a species determine how ECE affect the population. For a wider range in SST, both the mean and standard deviation had negative impact on log( λ s ), with changes in the mean having a greater effect than the standard deviation. Furthermore, around SST historical levels increases in either mean or standard deviation of the SST distribution led to a younger population, with potentially important conservation implications for black-browed albatrosses.This article is part of the themed issue 'Behavioural, ecological and evolutionary responses to extreme climatic events'. © 2017 The Author(s).

Top