Maaoui-Ben Hassine, Ikram; Naouar, Mohamed Wissem; Mrabet-Bellaaj, Najiba
2016-05-01
In this paper, Model Predictive Control and Dead-beat predictive control strategies are proposed for the control of a PMSG based wind energy system. The proposed MPC considers the model of the converter-based system to forecast the possible future behavior of the controlled variables. It allows selecting the voltage vector to be applied that leads to a minimum error by minimizing a predefined cost function. The main features of the MPC are low current THD and robustness against parameters variations. The Dead-beat predictive control is based on the system model to compute the optimum voltage vector that ensures zero-steady state error. The optimum voltage vector is then applied through Space Vector Modulation (SVM) technique. The main advantages of the Dead-beat predictive control are low current THD and constant switching frequency. The proposed control techniques are presented and detailed for the control of back-to-back converter in a wind turbine system based on PMSG. Simulation results (under Matlab-Simulink software environment tool) and experimental results (under developed prototyping platform) are presented in order to show the performances of the considered control strategies. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Determination of power system component parameters using nonlinear dead beat estimation method
NASA Astrophysics Data System (ADS)
Kolluru, Lakshmi
Power systems are considered the most complex man-made wonders in existence today. In order to effectively supply the ever increasing demands of the consumers, power systems are required to remain stable at all times. Stability and monitoring of these complex systems are achieved by strategically placed computerized control centers. State and parameter estimation is an integral part of these facilities, as they deal with identifying the unknown states and/or parameters of the systems. Advancements in measurement technologies and the introduction of phasor measurement units (PMU) provide detailed and dynamic information of all measurements. Accurate availability of dynamic measurements provides engineers the opportunity to expand and explore various possibilities in power system dynamic analysis/control. This thesis discusses the development of a parameter determination algorithm for nonlinear power systems, using dynamic data obtained from local measurements. The proposed algorithm was developed by observing the dead beat estimator used in state space estimation of linear systems. The dead beat estimator is considered to be very effective as it is capable of obtaining the required results in a fixed number of steps. The number of steps required is related to the order of the system and the number of parameters to be estimated. The proposed algorithm uses the idea of dead beat estimator and nonlinear finite difference methods to create an algorithm which is user friendly and can determine the parameters fairly accurately and effectively. The proposed algorithm is based on a deterministic approach, which uses dynamic data and mathematical models of power system components to determine the unknown parameters. The effectiveness of the algorithm is tested by implementing it to identify the unknown parameters of a synchronous machine. MATLAB environment is used to create three test cases for dynamic analysis of the system with assumed known parameters. Faults are introduced in the virtual test systems and the dynamic data obtained in each case is analyzed and recorded. Ideally, actual measurements are to be provided to the algorithm. As the measurements are not readily available the data obtained from simulations is fed into the determination algorithm as inputs. The obtained results are then compared to the original (or assumed) values of the parameters. The results obtained suggest that the algorithm is able to determine the parameters of a synchronous machine when crisp data is available.
BIVOUAC OF DEAD TABLET, THE MUFFLED DRUMS SAD ROLL HAS ...
BIVOUAC OF DEAD TABLET, THE MUFFLED DRUMS SAD ROLL HAS BEAT, SECTION 6. VIEW TO SOUTH. - Hot Springs National Cemetery, Virginia Medical Center 500 North Fifth Street, Hot Springs, Fall River County, SD
High-resolution echocardiography
NASA Technical Reports Server (NTRS)
Nathan, R.
1979-01-01
High resolution computer aided ultrasound system provides two-and three-dimensional images of beating heart from many angles. System provides means for determining whether small blood vessels around the heart are blocked or if heart wall is moving normally without interference of dead and noncontracting muscle tissue.
NuSTAR Captures the Beat of a Dead Star Animation
2014-10-08
The brightest pulsar detected to date is shown in this frame from an animation that flips back and forth between images captured by NASA NuSTAR. A pulsar is a type of neutron star, the leftover core of a star that exploded in a supernova.
Designing torus-doubling solutions to discrete time systems by hybrid projective synchronization
NASA Astrophysics Data System (ADS)
Xie, Hui; Wen, Guilin
2013-11-01
Doubling of torus occurs in high dimensional nonlinear systems, which is related to a certain kind of typical second bifurcations. It is a nontrivial task to create a torus-doubling solution with desired dynamical properties based on the classical bifurcation theories. In this paper, dead-beat hybrid projective synchronization is employed to build a novel method for designing stable torus-doubling solutions into discrete time systems with proper properties to achieve the purpose of utilizing bifurcation solutions as well as avoiding the possible conflict of physical meaning of the created solution. Although anti-controls of bifurcation and chaos synchronizations are two different topics in nonlinear dynamics and control, the results imply that it is possible to develop some new interdisciplinary methods between chaos synchronization and anti-controls of bifurcations.
Adaptive control in the presence of unmodeled dynamics. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Rohrs, C. E.
1982-01-01
Stability and robustness properties of a wide class of adaptive control algorithms in the presence of unmodeled dynamics and output disturbances were investigated. The class of adaptive algorithms considered are those commonly referred to as model reference adaptive control algorithms, self-tuning controllers, and dead beat adaptive controllers, developed for both continuous-time systems and discrete-time systems. A unified analytical approach was developed to examine the class of existing adaptive algorithms. It was discovered that all existing algorithms contain an infinite gain operator in the dynamic system that defines command reference errors and parameter errors; it is argued that such an infinite gain operator appears to be generic to all adaptive algorithms, whether they exhibit explicit or implicit parameter identification. It is concluded that none of the adaptive algorithms considered can be used with confidence in a practical control system design, because instability will set in with a high probability.
Koivikko, Minna L; Kenttä, Tuomas; Salmela, Pasi I; Huikuri, Heikki V; Perkiömäki, Juha S
2017-03-01
Experimental studies have revealed that hypoglycaemia can result in morphological changes in electrocardiographic repolarisation in subjects with type 1 diabetes. However, the influence of spontaneous nocturnal hypoglycaemia on repolarisation morphology in a 'real life' situation is not clear. Adults with type 1 diabetes (n = 11) underwent continuous glucose monitoring with a subcutaneous sensor and digital 12-lead ECG recording for three nights. T-wave morphology was analysed with custom-made software during both hypoglycaemia (glucose <3.5 mmol/l at least 20 min) from ten consecutive heart beats in the middle of the deepest hypoglycaemia and from a control nonhypoglycaemic period (glucose ≥5.0 mmol/l) from the same recording. In the comparison of 10 hypoglycaemia-control pairs, heart rate (65 ± 12 beats/min during normoglycaemia versus 85 ± 19 beats/min during hypoglycaemia, p = 0.028) increased and the QT c interval (439 ± 5 vs. 373 ± 5 ms, respectively, p = 0.025) decreased significantly during hypoglycaemia. The spatial QRS-T angle (TCRT) was reduced, and the roughness of the T-wave loop (T-E) increased significantly (p = 0.037 for both) in the patients during hypoglycaemia. In adults with type 1 diabetes, spontaneous nocturnal hypoglycaemia results in morphological changes and increased heterogeneity of global cardiac repolarisation. These changes may contribute to the risk of 'dead in bed' syndrome encountered in young individuals with type 1 diabetes.
Biomechanics of Tetrahymena escaping from a dead end
Kikuchi, Kenji
2018-01-01
Understanding the behaviours of swimming microorganisms in various environments is important for understanding cell distribution and growth in nature and industry. However, cell behaviour in complex geometries is largely unknown. In this study, we used Tetrahymena thermophila as a model microorganism and experimentally investigated cell behaviour between two flat plates with a small angle. In this configuration, the geometry provided a ‘dead end' line where the two flat plates made contact. The results showed that cells tended to escape from the dead end line more by hydrodynamics than by a biological reaction. In the case of hydrodynamic escape, the cell trajectories were symmetric as they swam to and from the dead end line. Near the dead end line, T. thermophila cells were compressed between the two flat plates while cilia kept beating with reduced frequency; those cells again showed symmetric trajectories, although the swimming velocity decreased. These behaviours were well reproduced by our computational model based on biomechanics. The mechanism of hydrodynamic escape can be understood in terms of the torque balance induced by lubrication flow. We therefore conclude that a cell's escape from the dead end was assisted by hydrodynamics. These findings pave the way for understanding cell behaviour and distribution in complex geometries. PMID:29491169
The quick and the dead: when reaction beats intention.
Welchman, Andrew E; Stanley, James; Schomers, Malte R; Miall, R Chris; Bülthoff, Heinrich H
2010-06-07
Everyday behaviour involves a trade-off between planned actions and reaction to environmental events. Evidence from neurophysiology, neurology and functional brain imaging suggests different neural bases for the control of different movement types. Here we develop a behavioural paradigm to test movement dynamics for intentional versus reaction movements and provide evidence for a 'reactive advantage' in movement execution, whereby the same action is executed faster in reaction to an opponent. We placed pairs of participants in competition with each other to make a series of button presses. Within-subject analysis of movement times revealed a 10 per cent benefit for reactive actions. This was maintained when opponents performed dissimilar actions, and when participants competed against a computer, suggesting that the effect is not related to facilitation produced by action observation. Rather, faster ballistic movements may be a general property of reactive motor control, potentially providing a useful means of promoting survival.
Wang, Qianggang; Zhou, Niancheng; Lou, Xiaoxuan; Chen, Xu
2014-01-01
Unbalanced grid faults will lead to several drawbacks in the output power quality of photovoltaic generation (PV) converters, such as power fluctuation, current amplitude swell, and a large quantity of harmonics. The aim of this paper is to propose a flexible AC current generation method by selecting coefficients to overcome these problems in an optimal way. Three coefficients are brought in to tune the output current reference within the required limits of the power quality (the current harmonic distortion, the AC current peak, the power fluctuation, and the DC voltage fluctuation). Through the optimization algorithm, the coefficients can be determined aiming to generate the minimum integrated amplitudes of the active and reactive power references with the constraints of the inverter current and DC voltage fluctuation. Dead-beat controller is utilized to track the optimal current reference in a short period. The method has been verified in PSCAD/EMTDC software.
Wang, Qianggang; Zhou, Niancheng; Lou, Xiaoxuan; Chen, Xu
2014-01-01
Unbalanced grid faults will lead to several drawbacks in the output power quality of photovoltaic generation (PV) converters, such as power fluctuation, current amplitude swell, and a large quantity of harmonics. The aim of this paper is to propose a flexible AC current generation method by selecting coefficients to overcome these problems in an optimal way. Three coefficients are brought in to tune the output current reference within the required limits of the power quality (the current harmonic distortion, the AC current peak, the power fluctuation, and the DC voltage fluctuation). Through the optimization algorithm, the coefficients can be determined aiming to generate the minimum integrated amplitudes of the active and reactive power references with the constraints of the inverter current and DC voltage fluctuation. Dead-beat controller is utilized to track the optimal current reference in a short period. The method has been verified in PSCAD/EMTDC software. PMID:25243215
Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.
Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi
2011-01-01
Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.
Ethical and legal issues in non-heart-beating organ donation.
Bos, Michael A
2005-05-15
Procurement of kidneys and livers from non-heart-beating donors (NHBD) raises ethical and legal issues that need to be considered before wider use of these donors is undertaken. Although NHBDs were used in kidney transplantation as early as the 1960s, retrieval of these organs is not universally accepted today. From a medical point of view, these organs were considered "marginal" because the majority showed delayed or impaired function early after implantation. Legal problems relate to determination of death on cardiopulmonary criteria, the issue of valid consent, and the use of preservation measures. Among ethical issues involved are observance of the dead-donor rule, decisions with respect to resuscitation and withdrawal of life-sustaining treatment, respect for the dying patient and the dead body, and proper guidance of the family. In The Netherlands NHB donation was pioneered by the Maastricht Centre as early as 1981. Today, all seven transplant centers procure and transplant these organs, and NHBDs have become an important source of transplantable kidneys and livers. Recent legislation in The Netherlands also supports NHB donation by allowing the use of organ-preserving measures, even in the absence of family consent. As a result, one of every three kidneys transplanted in The Netherlands in 2004 derives from a NHBD. This article explores Dutch NHBD practice, protocols, and results and compares these data internationally.
Shah, Seema K; Kasper, Kenneth; Miller, Franklin G
2015-04-01
Vital organ transplantation is premised on 'the dead donor rule': donors must be declared dead according to medical and legal criteria prior to donation. However, it is controversial whether individuals diagnosed as 'brain dead' are really dead in accordance with the established biological conception of death-the irreversible cessation of the functioning of the organism as a whole. A basic understanding of brain death is also relevant for giving valid, informed consent to serve as an organ donor. There is therefore a need for reliable empirical data on public understanding of brain death and vital organ transplantation. We conducted a review of the empirical literature that identified 43 articles with approximately 18,603 study participants. These data demonstrate that participants generally do not understand three key issues: (1) uncontested biological facts about brain death, (2) the legal status of brain death and (3) that organs are procured from brain dead patients while their hearts are still beating and before their removal from ventilators. These data suggest that, despite scholarly claims of widespread public support for organ donation from brain dead patients, the existing data on public attitudes regarding brain death and organ transplantation reflect substantial public confusion. Our review raises questions about the validity of consent for vital organ transplantation and suggests that existing data are of little assistance in developing policy proposals for organ transplantation from brain dead patients. New approaches to rigorous empirical research with educational components and evaluations of understanding are urgently needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
2017-12-08
The eerie glow of a dead star, which exploded long ago as a supernova, reveals itself in this NASA Hubble image of the Crab Nebula. But don't be fooled. The ghoulish-looking object still has a pulse. Buried at its center is the star's tell-tale heart, which beats with rhythmic precision. Credits: NASA and ESA, Acknowledgment: M. Weisskopf/Marshall Space Flight Center go.nasa.gov/2faTQ0V Credits: NASA and ESA, Acknowledgment: M. Weisskopf/Marshall Space Flight Center NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Of Climate Change and Crystal Balls: The Future Consequences of Climate Change in Africa
2012-01-01
Stationarity Is Dead For most of human existence, climate determined where and how we lived. Homo sapiens emerged sometime within the past half million...no. 1 ( January 2012): 35–50. 62. Schuyler Null, “ El Niño, Conflict, and Environmental Determinism: Assessing Climate’s Links to Instability,” New...Security Beat, 5 October 2011, http://www.newsecuritybeat.org/2011/10/ el -nino-conflict- and-environmental.html. 63. Ragnhild Nordås and Nils Petter
[Organ transplantation. Questions in the interface of ethics and anthropology].
Birnbacher, D
2014-08-01
In the field of organ transplantation medical ethics is confronted with a number of problems where the particular difficulty lies in the fact that ethical and anthropological questions interpenetrate. This article discusses two of these problems in this interface both of which are highly controversial: the real or apparent contradiction between the dead-donor rule and the traditional definition of death and the real or apparent contradiction between the ethical desirability of harvesting organs from non-heart beating donors and the irreversibility of brain death.
Wahbeh, Helané; Calabrese, Carlo; Zwickey, Heather; Zajdel, Dan
2007-03-01
When two auditory stimuli of different frequency are presented to each ear, binaural beats are perceived by the listener. The binaural beat frequency is equal to the difference between the frequencies applied to each ear. Our primary objective was to assess whether steady-state entrainment of electroencephalographic activity to the binaural beat occurs when exposed to a specific binaural beat frequency as has been hypothesized. Our secondary objective was to gather preliminary data on neuropsychologic and physiologic effects of binaural beat technology. A randomized, blinded, placebo-controlled crossover experiment in 4 healthy adult subjects. Subjects were randomized to experimental auditory stimulus of 30 minutes of binaural beat at 7 Hz (carrier frequencies: 133 Hz L; 140 Hz R) with an overlay of pink noise resembling the sound of rain on one session and control stimuli of the same overlay without the binaural beat carrier frequencies on the other session. Data were collected during two separate sessions 1 week apart. Neuropsychologic and blood pressure data were collected before and after the intervention; electroencephalographic data were collected before, during, and after listening to either binaural beats or control. Neuropsychologic measures included State Trait Anxiety Inventory, Profile of Mood States, Rey Auditory Verbal List Test, Stroop Test, and Controlled Oral Word Association Test. Spectral and coherence analysis was performed on the electroencephalogram (EEG), and all measures were analyzed for changes between sessions with and without binaural beat stimuli. There were no significant differences between the experimental and control conditions in any of the EEG measures. There was an increase of the Profile of Mood States depression subscale in the experimental condition relative to the control condition (p = 0.02). There was also a significant decrease in immediate verbal memory recall (p = 0.03) in the experimental condition compared to control condition. We did not find support for steady-state entrainment of the scalp-recorded EEG while listening to 7-Hz binaural beats. Although our data indicated increased depression and poorer immediate recall after listening to binaural beats, larger studies are needed to confirm these findings.
Death revisited: rethinking death and the dead donor rule.
Iltis, Ana Smith; Cherry, Mark J
2010-06-01
Traditionally, people were recognized as being dead using cardio-respiratory criteria: individuals who had permanently stopped breathing and whose heart had permanently stopped beating were dead. Technological developments in the middle of the twentieth century and the advent of the intensive care unit made it possible to sustain cardio-respiratory and other functions in patients with severe brain injury who previously would have lost such functions permanently shortly after sustaining a brain injury. What could and should physicians caring for such patients do? Significant advances in human organ transplantation also played direct and indirect roles in discussions regarding the care of such patients. Because successful transplantation requires that organs be removed from cadavers shortly after death to avoid organ damage due to loss of oxygen, there has been keen interest in knowing precisely when people are dead so that organs could be removed. Criteria for declaring death using neurological criteria developed, and today a whole brain definition of death is widely used and recognized by all 50 states in the United States as an acceptable way to determine death. We explore the ongoing debate over definitions of death, particularly over brain death or death determined using neurological criteria, and the relationship between definitions of death and organ transplantation.
Teng-Wei, Chen; Chung-Bao, Hsieh; Chan, De-Chuan; Yu, Jyh-Cherng; Kuo, Shih-Ming; Tsai, Chien-Sung; Fan, Hsiu-Lung
2014-12-29
Hemodynamic instability can lead to failure of donor organ procurement in brain-dead donors. Extracorporeal membrane oxygenation (ECMO) has been used in non-heart-beating donors to increase the donor pool, but the use of ECMO to salvage donor organs has been rarely used. We aimed to analyze postoperative liver function test results in patients receiving orthotopic liver transplants from ECMO-supported brain-dead donors. We retrospectively reviewed the records of 43 recipients of orthotopic liver transplantation from May 2009 to June 2012. Six recipients received liver grafts from ECMO-maintained donors designated as the ECMO group (n=6). The remaining patients were assigned to the non-ECMO group (n=37). Complication and mortality rates and liver function test results on postoperative days 1, 3, 5, 7, and 14 were compared between the 2 groups. Serum glutamate oxaloacetate transaminase and serum glutamate pyruvate transaminase levels were significantly elevated on postoperative Day 1 in the ECMO group. There were no significant differences in the complication and overall survival rates between the 2 groups (P=0.411). Although serum transaminases markedly elevated on postoperative Day 1, ECMO successfully preserved potential liver grafts in hemodynamically unstable brain-dead donors.
The role of beat gesture and pitch accent in semantic processing: an ERP study.
Wang, Lin; Chu, Mingyuan
2013-11-01
The present study investigated whether and how beat gesture (small baton-like hand movements used to emphasize information in speech) influences semantic processing as well as its interaction with pitch accent during speech comprehension. Event-related potentials were recorded as participants watched videos of a person gesturing and speaking simultaneously. The critical words in the spoken sentences were accompanied by a beat gesture, a control hand movement, or no hand movement, and were expressed either with or without pitch accent. We found that both beat gesture and control hand movement induced smaller negativities in the N400 time window than when no hand movement was presented. The reduced N400s indicate that both beat gesture and control movement facilitated the semantic integration of the critical word into the sentence context. In addition, the words accompanied by beat gesture elicited smaller negativities in the N400 time window than those accompanied by control hand movement over right posterior electrodes, suggesting that beat gesture has a unique role for enhancing semantic processing during speech comprehension. Finally, no interaction was observed between beat gesture and pitch accent, indicating that they affect semantic processing independently. © 2013 Elsevier Ltd. All rights reserved.
The Effect of Binaural Beats on Visuospatial Working Memory and Cortical Connectivity.
Beauchene, Christine; Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A; Leonessa, Alexander
2016-01-01
Binaural beats utilize a phenomenon that occurs within the cortex when two different frequencies are presented separately to each ear. This procedure produces a third phantom binaural beat, whose frequency is equal to the difference of the two presented tones and which can be manipulated for non-invasive brain stimulation. The effects of binaural beats on working memory, the system in control of temporary retention and online organization of thoughts for successful goal directed behavior, have not been well studied. Furthermore, no studies have evaluated the effects of binaural beats on brain connectivity during working memory tasks. In this study, we determined the effects of different acoustic stimulation conditions on participant response accuracy and cortical network topology, as measured by EEG recordings, during a visuospatial working memory task. Three acoustic stimulation control conditions and three binaural beat stimulation conditions were used: None, Pure Tone, Classical Music, 5Hz binaural beats, 10Hz binaural beats, and 15Hz binaural beats. We found that listening to 15Hz binaural beats during a visuospatial working memory task not only increased the response accuracy, but also modified the strengths of the cortical networks during the task. The three auditory control conditions and the 5Hz and 10Hz binaural beats all decreased accuracy. Based on graphical network analyses, the cortical activity during 15Hz binaural beats produced networks characteristic of high information transfer with consistent connection strengths throughout the visuospatial working memory task.
The Effect of Binaural Beats on Visuospatial Working Memory and Cortical Connectivity
Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A.; Leonessa, Alexander
2016-01-01
Binaural beats utilize a phenomenon that occurs within the cortex when two different frequencies are presented separately to each ear. This procedure produces a third phantom binaural beat, whose frequency is equal to the difference of the two presented tones and which can be manipulated for non-invasive brain stimulation. The effects of binaural beats on working memory, the system in control of temporary retention and online organization of thoughts for successful goal directed behavior, have not been well studied. Furthermore, no studies have evaluated the effects of binaural beats on brain connectivity during working memory tasks. In this study, we determined the effects of different acoustic stimulation conditions on participant response accuracy and cortical network topology, as measured by EEG recordings, during a visuospatial working memory task. Three acoustic stimulation control conditions and three binaural beat stimulation conditions were used: None, Pure Tone, Classical Music, 5Hz binaural beats, 10Hz binaural beats, and 15Hz binaural beats. We found that listening to 15Hz binaural beats during a visuospatial working memory task not only increased the response accuracy, but also modified the strengths of the cortical networks during the task. The three auditory control conditions and the 5Hz and 10Hz binaural beats all decreased accuracy. Based on graphical network analyses, the cortical activity during 15Hz binaural beats produced networks characteristic of high information transfer with consistent connection strengths throughout the visuospatial working memory task. PMID:27893766
Hsiu, Hsin; Chen, Chao-Tsung; Hung, Shuo-Hui; Chen, Guan-Zhang; Huang, Yu-Ling
2018-04-13
There is an urgent need to improve the early diagnosis of breast cancer. The present study applied spectral and beat-to-beat analyses to laser-Doppler (LDF) data sequences measured on the skin surface on the back of the right hands, with the aim of comparing the different peripheral microcirculatory-blood-flow (MBF) perfusion condition between breast-cancer and control subjects. ECG and LDF signals were obtained simultaneously and noninvasively from 23 breast-cancer patients and 23 age-matched control subjects. Time-domain beat-to-beat indexes and their variability parameters were calculated. Spectral indexes were calculated using the Morlet wavelet transform. The beat-to-beat LDF pulse width and its variability were significantly smaller in cancer patients than in the controls. The energy contributions of endothelial-, neural-, and myogenic-related frequency bands were also significantly smaller in cancer patients. The present study has revealed significant differences in the beat-to-beat and spectral indexes of skin-surface-acquired LDF signals between control subjects and breast-cancer patients. This illustrates that LDF indexes may be useful for monitoring the changes in the MBF perfusion condition induced by breast cancer. Since the breast-cancer patients were at TNM stages 0- 2, the present findings may aid the development of indexes for detecting breast cancer.
More attentional focusing through binaural beats: evidence from the global-local task.
Colzato, Lorenza S; Barone, Hayley; Sellaro, Roberta; Hommel, Bernhard
2017-01-01
A recent study showed that binaural beats have an impact on the efficiency of allocating attention over time. We were interested to see whether this impact affects attentional focusing or, even further, the top-down control over irrelevant information. Healthy adults listened to gamma-frequency (40 Hz) binaural beats, which are assumed to increase attentional concentration, or a constant tone of 340 Hz (control condition) for 3 min before and during a global-local task. While the size of the congruency effect (indicating the failure to suppress task-irrelevant information) was unaffected by the binaural beats, the global-precedence effect (reflecting attentional focusing) was considerably smaller after gamma-frequency binaural beats than after the control condition. Our findings suggest that high-frequency binaural beats bias the individual attentional processing style towards a reduced spotlight of attention.
Ethical and legal issues in non-heart-beating organ donation.
Bos, M A
2005-03-01
Procurement of kidneys and livers from non-heart-beating donors (NHBDs) raises ethical and legal issues that need to be considered carefully before wider use of these donors. Although NHBDs were used in kidney transplantation as early as the 1960s, retrieval of these organs is by no means universally accepted today. From a medical point of view, these organs have long been considered "marginal" because the majority show delayed or impaired graft function. Legal problems include determination of death by cardiopulmonary criteria, the issue of proper consent, and the use of organ preservation measures. Among ethical issues raised are the observance of the Dead-donor Rule, the decision-making surrounding resuscitation, the withdrawal of life-support, the respect for a dying patient and the dead body, as well as proper information to and guidance for the family. In the Netherlands NHB donation was pioneered in the Maastricht Medical Center in 1980s. Today, all seven transplant centers retrieve and transplant organs from these donors, and NHBDs have become an important source of transplantable kidneys and livers. Recent legislation in the Netherlands also supports the use of NHBDs by making possible the use of organ preservation measures after circulatory arrest, even in the absence of family consent. As a result, one of every three kidneys transplanted in the Netherlands in 2004 was obtained from a NHBD. In this study, Dutch NHBD protocols, practice, and results are analyzed and compared with international practices.
The Impact of Monaural Beat Stimulation on Anxiety and Cognition.
Chaieb, Leila; Wilpert, Elke C; Hoppe, Christian; Axmacher, Nikolai; Fell, Juergen
2017-01-01
Application of auditory beat stimulation has been speculated to provide a promising new tool with which to alleviate symptoms of anxiety and to enhance cognition. In spite of reportedly similar EEG effects of binaural and monaural beats, data on behavioral effects of monaural beats are still lacking. Therefore, we examined the impact of monaural beat stimulation on anxiety, mood and memory performance. We aimed to target states related to anxiety levels and general well-being, in addition to long-term and working memory processes, using monaural beats within the range of main cortical rhythms. Theta (6 Hz), alpha (10 Hz) and gamma (40 Hz) beat frequencies, as well as a control stimulus were applied to healthy participants for 5 min. After each stimulation period, participants were asked to evaluate their current mood state and to perform cognitive tasks examining long-term and working memory processes, in addition to a vigilance task. Monaural beat stimulation was found to reduce state anxiety. When evaluating responses for the individual beat frequencies, positive effects on state anxiety were observed for all monaural beat conditions compared to control stimulation. Our results indicate a role for monaural beat stimulation in modulating state anxiety and are in line with previous studies reporting anxiety-reducing effects of auditory beat stimulation.
The Impact of Monaural Beat Stimulation on Anxiety and Cognition
Chaieb, Leila; Wilpert, Elke C.; Hoppe, Christian; Axmacher, Nikolai; Fell, Juergen
2017-01-01
Application of auditory beat stimulation has been speculated to provide a promising new tool with which to alleviate symptoms of anxiety and to enhance cognition. In spite of reportedly similar EEG effects of binaural and monaural beats, data on behavioral effects of monaural beats are still lacking. Therefore, we examined the impact of monaural beat stimulation on anxiety, mood and memory performance. We aimed to target states related to anxiety levels and general well-being, in addition to long-term and working memory processes, using monaural beats within the range of main cortical rhythms. Theta (6 Hz), alpha (10 Hz) and gamma (40 Hz) beat frequencies, as well as a control stimulus were applied to healthy participants for 5 min. After each stimulation period, participants were asked to evaluate their current mood state and to perform cognitive tasks examining long-term and working memory processes, in addition to a vigilance task. Monaural beat stimulation was found to reduce state anxiety. When evaluating responses for the individual beat frequencies, positive effects on state anxiety were observed for all monaural beat conditions compared to control stimulation. Our results indicate a role for monaural beat stimulation in modulating state anxiety and are in line with previous studies reporting anxiety-reducing effects of auditory beat stimulation. PMID:28555100
Becher, Ann-Katrin; Höhne, Marlene; Axmacher, Nikolai; Chaieb, Leila; Elger, Christian E; Fell, Juergen
2015-01-01
Auditory stimulation with monaural or binaural auditory beats (i.e. sine waves with nearby frequencies presented either to both ears or to each ear separately) represents a non-invasive approach to influence electrical brain activity. It is still unclear exactly which brain sites are affected by beat stimulation. In particular, an impact of beat stimulation on mediotemporal brain areas could possibly provide new options for memory enhancement or seizure control. Therefore, we examined how electroencephalography (EEG) power and phase synchronization are modulated by auditory stimulation with beat frequencies corresponding to dominant EEG rhythms based on intracranial recordings in presurgical epilepsy patients. Monaural and binaural beat stimuli with beat frequencies of 5, 10, 40 and 80 Hz and non-superposed control signals were administered with low amplitudes (60 dB SPL) and for short durations (5 s). EEG power was intracranially recorded from mediotemporal, temporo-basal and temporo-lateral and surface sites. Evoked and total EEG power and phase synchronization during beat vs. control stimulation were compared by the use of Bonferroni-corrected non-parametric label-permutation tests. We found that power and phase synchronization were significantly modulated by beat stimulation not only at temporo-basal, temporo-lateral and surface sites, but also at mediotemporal sites. Generally, more significant decreases than increases were observed. The most prominent power increases were seen after stimulation with monaural 40-Hz beats. The most pronounced power and synchronization decreases resulted from stimulation with monaural 5-Hz and binaural 80-Hz beats. Our results suggest that beat stimulation offers a non-invasive approach for the modulation of intracranial EEG characteristics. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Losing the beat: deficits in temporal coordination.
Palmer, Caroline; Lidji, Pascale; Peretz, Isabelle
2014-12-19
Tapping or clapping to an auditory beat, an easy task for most individuals, reveals precise temporal synchronization with auditory patterns such as music, even in the presence of temporal fluctuations. Most models of beat-tracking rely on the theoretical concept of pulse: a perceived regular beat generated by an internal oscillation that forms the foundation of entrainment abilities. Although tapping to the beat is a natural sensorimotor activity for most individuals, not everyone can track an auditory beat. Recently, the case of Mathieu was documented (Phillips-Silver et al. 2011 Neuropsychologia 49, 961-969. (doi:10.1016/j.neuropsychologia.2011.02.002)). Mathieu presented himself as having difficulty following a beat and exhibited synchronization failures. We examined beat-tracking in normal control participants, Mathieu, and a second beat-deaf individual, who tapped with an auditory metronome in which unpredictable perturbations were introduced to disrupt entrainment. Both beat-deaf cases exhibited failures in error correction in response to the perturbation task while exhibiting normal spontaneous motor tempi (in the absence of an auditory stimulus), supporting a deficit specific to perception-action coupling. A damped harmonic oscillator model was applied to the temporal adaptation responses; the model's parameters of relaxation time and endogenous frequency accounted for differences between the beat-deaf cases as well as the control group individuals.
Losing the beat: deficits in temporal coordination
Palmer, Caroline; Lidji, Pascale; Peretz, Isabelle
2014-01-01
Tapping or clapping to an auditory beat, an easy task for most individuals, reveals precise temporal synchronization with auditory patterns such as music, even in the presence of temporal fluctuations. Most models of beat-tracking rely on the theoretical concept of pulse: a perceived regular beat generated by an internal oscillation that forms the foundation of entrainment abilities. Although tapping to the beat is a natural sensorimotor activity for most individuals, not everyone can track an auditory beat. Recently, the case of Mathieu was documented (Phillips-Silver et al. 2011 Neuropsychologia 49, 961–969. (doi:10.1016/j.neuropsychologia.2011.02.002)). Mathieu presented himself as having difficulty following a beat and exhibited synchronization failures. We examined beat-tracking in normal control participants, Mathieu, and a second beat-deaf individual, who tapped with an auditory metronome in which unpredictable perturbations were introduced to disrupt entrainment. Both beat-deaf cases exhibited failures in error correction in response to the perturbation task while exhibiting normal spontaneous motor tempi (in the absence of an auditory stimulus), supporting a deficit specific to perception–action coupling. A damped harmonic oscillator model was applied to the temporal adaptation responses; the model's parameters of relaxation time and endogenous frequency accounted for differences between the beat-deaf cases as well as the control group individuals. PMID:25385783
3D force control for robotic-assisted beating heart surgery based on viscoelastic tissue model.
Liu, Chao; Moreira, Pedro; Zemiti, Nabil; Poignet, Philippe
2011-01-01
Current cardiac surgery faces the challenging problem of heart beating motion even with the help of mechanical stabilizer which makes delicate operation on the heart surface difficult. Motion compensation methods for robotic-assisted beating heart surgery have been proposed recently in literature, but research on force control for such kind of surgery has hardly been reported. Moreover, the viscoelasticity property of the interaction between organ tissue and robotic instrument further complicates the force control design which is much easier in other applications by assuming the interaction model to be elastic (industry, stiff object manipulation, etc.). In this work, we present a three-dimensional force control method for robotic-assisted beating heart surgery taking into consideration of the viscoelastic interaction property. Performance studies based on our D2M2 robot and 3D heart beating motion information obtained through Da Vinci™ system are provided.
The effect of gamma-enhancing binaural beats on the control of feature bindings.
Colzato, Lorenza S; Steenbergen, Laura; Sellaro, Roberta
2017-07-01
Binaural beats represent the auditory experience of an oscillating sound that occurs when two sounds with neighboring frequencies are presented to one's left and right ear separately. Binaural beats have been shown to impact information processing via their putative role in increasing neural synchronization. Recent studies of feature-repetition effects demonstrated interactions between perceptual features and action-related features: repeating only some, but not all features of a perception-action episode hinders performance. These partial-repetition (or binding) costs point to the existence of temporary episodic bindings (event files) that are automatically retrieved by repeating at least one of their features. Given that neural synchronization in the gamma band has been associated with visual feature bindings, we investigated whether the impact of binaural beats extends to the top-down control of feature bindings. Healthy adults listened to gamma-frequency (40 Hz) binaural beats or to a constant tone of 340 Hz (control condition) for ten minutes before and during a feature-repetition task. While the size of visuomotor binding costs (indicating the binding of visual and action features) was unaffected by the binaural beats, the size of visual feature binding costs (which refer to the binding between the two visual features) was considerably smaller during gamma-frequency binaural beats exposure than during the control condition. Our results suggest that binaural beats enhance selectivity in updating episodic memory traces and further strengthen the hypothesis that neural activity in the gamma band is critically associated with the control of feature binding.
Jirakittayakorn, Nantawachara; Wongsawat, Yodchanan
2017-01-01
A binaural beat is a beat phenomenon that is generated by the dichotic presentation of two almost equivalent pure tones but with slightly different frequencies. The brain responses to binaural beats remain controversial; therefore, the aim of this study was to investigate theta activity responses to a binaural beat by controlling factors affecting localization, including beat frequency, carrier tone frequency, exposure duration, and recording procedure. Exposure to a 6-Hz binaural beat on a 250 Hz carrier tone for 30 min was utilized in this study. Quantitative electroencephalography (QEEG) was utilized as the recording modality. Twenty-eight participants were divided into experimental and control groups. Emotional states were evaluated by Brunel Mood Scale (BRMUS) before and after exposing to the stimulus. The results showed that theta activity was induced in the entire cortex within 10 min of exposure to the stimulus in the experimental group. Compared to the control group, theta activity was also induced at the frontal and parietal-central regions, which included the Fz position, and left hemisphere dominance was presented for other exposure durations. The pattern recorded for 10 min of exposure appeared to be brain functions of a meditative state. Moreover, tension factor of BRUMS was decreased in experimental group compared to control group which resembled the meditation effect. Thus, a 6-Hz binaural beat on a 250 Hz carrier tone was suggested as a stimulus for inducing a meditative state. PMID:28701912
Jirakittayakorn, Nantawachara; Wongsawat, Yodchanan
2017-01-01
A binaural beat is a beat phenomenon that is generated by the dichotic presentation of two almost equivalent pure tones but with slightly different frequencies. The brain responses to binaural beats remain controversial; therefore, the aim of this study was to investigate theta activity responses to a binaural beat by controlling factors affecting localization, including beat frequency, carrier tone frequency, exposure duration, and recording procedure. Exposure to a 6-Hz binaural beat on a 250 Hz carrier tone for 30 min was utilized in this study. Quantitative electroencephalography (QEEG) was utilized as the recording modality. Twenty-eight participants were divided into experimental and control groups. Emotional states were evaluated by Brunel Mood Scale (BRMUS) before and after exposing to the stimulus. The results showed that theta activity was induced in the entire cortex within 10 min of exposure to the stimulus in the experimental group. Compared to the control group, theta activity was also induced at the frontal and parietal-central regions, which included the Fz position, and left hemisphere dominance was presented for other exposure durations. The pattern recorded for 10 min of exposure appeared to be brain functions of a meditative state. Moreover, tension factor of BRUMS was decreased in experimental group compared to control group which resembled the meditation effect. Thus, a 6-Hz binaural beat on a 250 Hz carrier tone was suggested as a stimulus for inducing a meditative state.
Environmental Toxin Screening Using Human-Derived 3D Bioengineered Liver and Cardiac Organoids.
Forsythe, Steven D; Devarasetty, Mahesh; Shupe, Thomas; Bishop, Colin; Atala, Anthony; Soker, Shay; Skardal, Aleksander
2018-01-01
Environmental toxins, such as lead and other heavy metals, pesticides, and other compounds, represent a significant health concern within the USA and around the world. Even in the twenty-first century, a plethora of cities and towns in the U.S. have suffered from exposures to lead in drinking water or other heavy metals in food or the earth, while there is a high possibility of further places to suffer such exposures in the near future. We employed bioengineered 3D human liver and cardiac organoids to screen a panel of environmental toxins (lead, mercury, thallium, and glyphosate), and charted the response of the organoids to these compounds. Liver and cardiac organoids were exposed to lead (10 µM-10 mM), mercury (200 nM-200 µM), thallium (10 nM-10 µM), or glyphosate (25 µM-25 mM) for a duration of 48 h. The impacts of toxin exposure were then assessed by LIVE/DEAD viability and cytotoxicity staining, measuring ATP activity and determining IC50 values, and determining changes in cardiac organoid beating activity. As expected, all of the toxins induced toxicity in the organoids. Both ATP and LIVE/DEAD assays showed toxicity in both liver and cardiac organoids. In particular, thallium was the most toxic, with IC50 values of 13.5 and 1.35 µM in liver and cardiac organoids, respectively. Conversely, glyphosate was the least toxic of the four compounds, with IC50 values of 10.53 and 10.85 mM in liver and cardiac organoids, respectively. Additionally, toxins had a negative influence on cardiac organoid beating activity as well. Thallium resulting in the most significant decreases in beating rate, followed by mercury, then glyphosate, and finally, lead. These results suggest that the 3D organoids have significant utility to be deployed in additional toxicity screening applications, and future development of treatments to mitigate exposures. 3D organoids have significant utility to be deployed in additional toxicity screening applications, such as future development of treatments to mitigate exposures, drug screening, and environmental toxin detection.
Healthcare performance and the effects of the binaural beats on human blood pressure and heart rate.
Carter, Calvin
2008-01-01
Binaural beats are the differences in two different frequencies (in the range of 30-1000 Hz). Binaural beats are played through headphones and are perceived by the superior olivary nucleus of each hemisphere of the brain. The brain perceives the binaural beat and resonates to its frequency (frequency following response). Once the brain is in tune with the binaural beat it produces brainwaves of that frequency altering the listener's state of mind. In this experiment, the effects of the beta and theta binaural beat on human blood pressure and pulse were studied. Using headphones, three sounds were played for 7 minutes each to 12 participants: the control,- the sound of a babbling brook (the background sound to the two binaural beats), the beta binaural beat (20 Hz), and the theta binaural beat (7 Hz). Blood pressure and pulse were recorded before and after each sound was played. Each participant was given 2 minutes in-between each sound. The results showed that the control and the two binaural beats did not affect the 12 participant's blood pressure or pulse (p > 0.05). One reason for this may be that the sounds were not played long enough for the brain to either perceive and/or resonate to the frequency. Another reason why the sounds did not affect blood pressure and pulse may be due to the participant's age since older brains may not perceive the binaural beats as well as younger brains.
Loomba, Rohit S; Bhushan, Abhinav; Afolayan, Adeleye J
2018-05-03
Cilia are involved in several physiologic processes, and at least a single primary cilium can be found on nearly every cell in the human body. Various factors, such as pH, temperature, exposure to medications and toxins can impact ciliary function as is manifested by changes in the ciliary beat frequency. Those with ciliary dyskinesia may also have congenital cardiac malformations and may require care in a cardiac intensive care unit. This study investigates the effect on the ciliary beat frequency of medications frequently used in a cardiac intensive care unit. The ciliated epithelial cells were obtained via nasal swab from a relatively healthy individual. These cells were cultured for 24 h. Video microscopy was then employed to determine the ciliary beat frequency at baseline and then at 15, 30, 60 and 90 min after exposure to either normal saline (control) or one of several medications. The ciliary beat frequency at each time point was then compared to the ciliary beat frequency at the same time point in the control sample as well as the baseline value for that particular sample. Epinephrine increased the ciliary beat frequency compared to the baseline and the controls up to 30 min and then subsequently led to a significant decrease in ciliary beat frequency at 90 min. On the one hand, norepinephrine, dexmedetomidine, procainamide, propranolol and enalapril all decreased ciliary beat frequency significantly throughout the 90-min observation period. On the other hand, Milrinone significantly increased the ciliary beat frequency throughout the observation period, while heparin had no impact on ciliary beat frequency. The medications frequently used in cardiac intensive care unit impact ciliary function, with most being ciliodepressant. Further investigation is needed to determine the clinical impacts and whether these effects are exaggerated in those with ciliary dyskinesia.
Maurovich-Horvat, Pál; Károlyi, Mihály; Horváth, Tamás; Szilveszter, Bálint; Bartykowszki, Andrea; Jermendy, Ádám L; Panajotu, Alexisz; Celeng, Csilla; Suhai, Ferenc I; Major, Gyöngyi P; Csobay-Novák, Csaba; Hüttl, Kálmán; Merkely, Béla
2015-01-01
Coronary CT angiography (CTA) is an established tool to rule out coronary artery disease. Performance of coronary CTA is highly dependent on patients' heart rates (HRs). Despite widespread use of β-blockers for coronary CTA, few studies have compared various agents used to achieve adequate HR control. We sought to assess if the ultrashort-acting β-blocker intravenous esmolol is at least as efficacious as the standard of care intravenous metoprolol for HR control during coronary CTA. Patients referred to coronary CTA with a HR >65 beats/min despite oral metoprolol premedication were enrolled in the study. We studied 412 patients (211 male; mean age, 57 ± 12 years). Two hundred four patients received intravenous esmolol, and 208 received intravenous metoprolol with a stepwise bolus administration protocol. HR and blood pressure were recorded at arrival, before, during, immediately after, and 30 minutes after the coronary CTA scan. Mean HRs of the esmolol and metoprolol groups were similar at arrival (78 ± 13 beats/min vs 77 ± 12 beats/min; P = .65) and before scan (68 ± 7 beats/min vs 69 ± 7 beats/min; P = .60). However, HR during scan was lower in the esmolol group vs the metoprolol group (58 ± 6 beats/min vs 61 ± 7 beats/min; P < .0001), whereas HRs immediately and 30 minutes after the scan were higher in the esmolol group vs the metoprolol group (68 ± 7 beats/min vs 66 ± 7 beats/min; P = .01 and 65 ± 8 beats/min vs 63 ± 8 beats/min; P < .0001; respectively). HR ≤ 65 beats/min was reached in 182 of 204 patients (89%) who received intravenous esmolol vs 162 of 208 of the patients (78%) who received intravenous metoprolol (P < .05). Of note, hypotension (systolic BP <100 mm Hg) was observed right after the scan in 19 patients (9.3%) in the esmolol group and in 8 patients (3.8%) in the metoprolol group (P < .05), whereas only 5 patients (2.5%) had hypotension 30 minutes after the scan in the esmolol group compared to 8 patients (3.8%) in the metoprolol group (P = .418). Intravenous esmolol with a stepwise bolus administration protocol is at least as efficacious as the standard of care intravenous metoprolol for HR control in patients who undergo coronary CTA. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Binaural auditory beats affect vigilance performance and mood.
Lane, J D; Kasian, S J; Owens, J E; Marsh, G R
1998-01-01
When two tones of slightly different frequency are presented separately to the left and right ears the listener perceives a single tone that varies in amplitude at a frequency equal to the frequency difference between the two tones, a perceptual phenomenon known as the binaural auditory beat. Anecdotal reports suggest that binaural auditory beats within the electroencephalograph frequency range can entrain EEG activity and may affect states of consciousness, although few scientific studies have been published. This study compared the effects of binaural auditory beats in the EEG beta and EEG theta/delta frequency ranges on mood and on performance of a vigilance task to investigate their effects on subjective and objective measures of arousal. Participants (n = 29) performed a 30-min visual vigilance task on three different days while listening to pink noise containing simple tones or binaural beats either in the beta range (16 and 24 Hz) or the theta/delta range (1.5 and 4 Hz). However, participants were kept blind to the presence of binaural beats to control expectation effects. Presentation of beta-frequency binaural beats yielded more correct target detections and fewer false alarms than presentation of theta/delta frequency binaural beats. In addition, the beta-frequency beats were associated with less negative mood. Results suggest that the presentation of binaural auditory beats can affect psychomotor performance and mood. This technology may have applications for the control of attention and arousal and the enhancement of human performance.
High-Frequency Binaural Beats Increase Cognitive Flexibility: Evidence from Dual-Task Crosstalk.
Hommel, Bernhard; Sellaro, Roberta; Fischer, Rico; Borg, Saskia; Colzato, Lorenza S
2016-01-01
Increasing evidence suggests that cognitive-control processes can be configured to optimize either persistence of information processing (by amplifying competition between decision-making alternatives and top-down biasing of this competition) or flexibility (by dampening competition and biasing). We investigated whether high-frequency binaural beats, an auditory illusion suspected to act as a cognitive enhancer, have an impact on cognitive-control configuration. We hypothesized that binaural beats in the gamma range bias the cognitive-control style toward flexibility, which in turn should increase the crosstalk between tasks in a dual-task paradigm. We replicated earlier findings that the reaction time in the first-performed task is sensitive to the compatibility between the responses in the first and the second task-an indication of crosstalk. As predicted, exposing participants to binaural beats in the gamma range increased this effect as compared to a control condition in which participants were exposed to a continuous tone of 340 Hz. These findings provide converging evidence that the cognitive-control style can be systematically biased by inducing particular internal states; that high-frequency binaural beats bias the control style toward more flexibility; and that different styles are implemented by changing the strength of local competition and top-down bias.
High-Frequency Binaural Beats Increase Cognitive Flexibility: Evidence from Dual-Task Crosstalk
Hommel, Bernhard; Sellaro, Roberta; Fischer, Rico; Borg, Saskia; Colzato, Lorenza S.
2016-01-01
Increasing evidence suggests that cognitive-control processes can be configured to optimize either persistence of information processing (by amplifying competition between decision-making alternatives and top-down biasing of this competition) or flexibility (by dampening competition and biasing). We investigated whether high-frequency binaural beats, an auditory illusion suspected to act as a cognitive enhancer, have an impact on cognitive-control configuration. We hypothesized that binaural beats in the gamma range bias the cognitive-control style toward flexibility, which in turn should increase the crosstalk between tasks in a dual-task paradigm. We replicated earlier findings that the reaction time in the first-performed task is sensitive to the compatibility between the responses in the first and the second task—an indication of crosstalk. As predicted, exposing participants to binaural beats in the gamma range increased this effect as compared to a control condition in which participants were exposed to a continuous tone of 340 Hz. These findings provide converging evidence that the cognitive-control style can be systematically biased by inducing particular internal states; that high-frequency binaural beats bias the control style toward more flexibility; and that different styles are implemented by changing the strength of local competition and top-down bias. PMID:27605922
Eliminating the Attentional Blink through Binaural Beats: A Case for Tailored Cognitive Enhancement.
Reedijk, Susan A; Bolders, Anne; Colzato, Lorenza S; Hommel, Bernhard
2015-01-01
Enhancing human cognitive performance is a topic that continues to spark scientific interest. Studies into cognitive-enhancement techniques often fail to take inter-individual differences into account, however, which leads to underestimation of the effectiveness of these techniques. The current study investigated the effect of binaural beats, a cognitive-enhancement technique, on attentional control in an attentional blink (AB) task. As predicted from a neurocognitive approach to cognitive control, high-frequency binaural beats eliminated the AB, but only in individuals with low spontaneous eye-blink rates (indicating low striatal dopamine levels). This suggests that the way in which cognitive-enhancement techniques, such as binaural beats, affect cognitive performance depends on inter-individual differences.
Sasaki, Toshiya; Oh, Ki-Bong; Matsuoka, Hideaki; Saito, Mikako
2008-03-01
Bioactive compounds that may control the specific differentiation from mouse embryonic stem (ES) cells into cardiac-like cells have been screened from herbal medicines. Among seven preparations, Panax ginseng was found to promote the differentiation into beating cells and to sustain their beating for longer than the control. Active compounds were found in its water-soluble fraction. Although they were not isolated, their candidates were surveyed in 42 compounds selected from the database of P. ginseng. Finally we found that vitamin B12 (VB12) and methionine were active. VB12 accelerated the differentiation into beating cells and made the beating rate constantly 100%. Moreover, VB12 was effective in the recovery of beating that was inhibited by spermine action. The mechanism of action of VB12 is discussed in termo of the relevance of intercellular electrical signal transduction.
Wiwatwongwana, D; Vichitvejpaisal, P; Thaikruea, L; Klaphajone, J; Tantong, A; Wiwatwongwana, A
2016-01-01
Purpose To investigate the anxiolytic effects of binaural beat embedded audio in patients undergoing cataract surgery under local anesthesia. Methods This prospective RCT included 141 patients undergoing cataract surgery under local anesthesia. The patients were randomized into three groups; the Binaural beat music group (BB), the plain music intervention group (MI), and a control group (ear phones with no music). Blood pressure (BP) and heart rate were measured on admission, at the beginning of and 20 min after the start of the operation. Peri-operative anxiety level was assessed using the State-Trait Anxiety Inventory questionnaire (STAI). Results The BB and MI groups comprised 44 patients each and the control group 47. Patients in the MI group and BB group showed significant reduction of STAI state scores after music intervention compared with the control group (P<0.001) but the difference was not significant between the MI and BB group (STAI-S score MI group −7.0, BB group −9.0, P=0.085). Systolic BP was significantly lower in both MI (P=0.043) and BB (0.040) groups although there was no difference between the two groups (P=1.000). A significant reduction in heart rate was seen only in the BB group (BB vs control P=0.004, BB vs MI P=0.050, MI vs control P=0.303). Conclusion Music, both with and without binaural beat, was proven to decrease anxiety level and lower systolic BP. Patients who received binaural beat audio showed additional decrease in heart rate. Binaural beat embedded musical intervention may have benefit over musical intervention alone in decreasing operative anxiety. PMID:27740618
Wiwatwongwana, D; Vichitvejpaisal, P; Thaikruea, L; Klaphajone, J; Tantong, A; Wiwatwongwana, A
2016-11-01
PurposeTo investigate the anxiolytic effects of binaural beat embedded audio in patients undergoing cataract surgery under local anesthesia.MethodsThis prospective RCT included 141 patients undergoing cataract surgery under local anesthesia. The patients were randomized into three groups; the Binaural beat music group (BB), the plain music intervention group (MI), and a control group (ear phones with no music). Blood pressure (BP) and heart rate were measured on admission, at the beginning of and 20 min after the start of the operation. Peri-operative anxiety level was assessed using the State-Trait Anxiety Inventory questionnaire (STAI).ResultsThe BB and MI groups comprised 44 patients each and the control group 47. Patients in the MI group and BB group showed significant reduction of STAI state scores after music intervention compared with the control group (P<0.001) but the difference was not significant between the MI and BB group (STAI-S score MI group -7.0, BB group -9.0, P=0.085). Systolic BP was significantly lower in both MI (P=0.043) and BB (0.040) groups although there was no difference between the two groups (P=1.000). A significant reduction in heart rate was seen only in the BB group (BB vs control P=0.004, BB vs MI P=0.050, MI vs control P=0.303).ConclusionMusic, both with and without binaural beat, was proven to decrease anxiety level and lower systolic BP. Patients who received binaural beat audio showed additional decrease in heart rate. Binaural beat embedded musical intervention may have benefit over musical intervention alone in decreasing operative anxiety.
Eliminating the Attentional Blink through Binaural Beats: A Case for Tailored Cognitive Enhancement
Reedijk, Susan A.; Bolders, Anne; Colzato, Lorenza S.; Hommel, Bernhard
2015-01-01
Enhancing human cognitive performance is a topic that continues to spark scientific interest. Studies into cognitive-enhancement techniques often fail to take inter-individual differences into account, however, which leads to underestimation of the effectiveness of these techniques. The current study investigated the effect of binaural beats, a cognitive-enhancement technique, on attentional control in an attentional blink (AB) task. As predicted from a neurocognitive approach to cognitive control, high-frequency binaural beats eliminated the AB, but only in individuals with low spontaneous eye-blink rates (indicating low striatal dopamine levels). This suggests that the way in which cognitive-enhancement techniques, such as binaural beats, affect cognitive performance depends on inter-individual differences. PMID:26089802
NASA Astrophysics Data System (ADS)
Bao, Qian-Qian; Zhang, Yan; Cui, Cui-Li; Meng, Shao-Ying; Fang, You-Wei; Tian, Xue-Dong
2018-04-01
We propose an efficient scheme for generating and controlling beating stationary light pulses in a five-level atomic sample driven into electromagnetically induced transparency condition. This scheme relies on an asymmetrical procedure of light storage and retrieval tuned by two counter-propagating control fields where an additional coupling field, such as the microwave field, is introduced in the retrieval stage. A quantum probe field, incident upon such an atomic sample, is first transformed into spin coherence excitation of the atoms and then retrieved as beating stationary light pulses exhibiting a series of maxima and minima in intensity due to the alternative constructive and destructive interference. It is convenient to control the beating stationary light pulses just by manipulating the intensity and detuning of the additional microwave field. This interesting phenomenon involves in fact the coherent manipulation of dark-state polaritons and could be explored to achieve the efficient temporal splitting of stationary light pulses and accurate measurement of the microwave intensity.
Grahn, Jessica A.; Rowe, James B.
2009-01-01
Little is known about the underlying neurobiology of rhythm and beat perception, despite its universal cultural importance. Here we used functional magnetic resonance imaging to study rhythm perception in musicians and non-musicians. Three conditions varied in the degree to which external reinforcement versus internal generation of the beat was required. The ‘Volume’ condition strongly externally marked the beat with volume changes, the ‘Duration’ condition marked the beat with weaker accents arising from duration changes, and the ‘Unaccented’ condition required the beat to be entirely internally generated. In all conditions, beat rhythms compared to nonbeat control rhythms revealed putamen activity. The presence of a beat was also associated with greater connectivity between the putamen and the supplementary motor area (SMA), the premotor cortex (PMC) and auditory cortex. In contrast, the type of accent within the beat conditions modulated the coupling between premotor and auditory cortex, with greater modulation for musicians than non-musicians. Importantly, the putamen's response to beat conditions was not due to differences in temporal complexity between the three rhythm conditions. We propose that a cortico-subcortical network including the putamen, SMA, and PMC is engaged for the analysis of temporal sequences and prediction or generation of putative beats, especially under conditions that may require internal generation of the beat. The importance of this system for auditory-motor interaction and development of precisely timed movement is suggested here by its facilitation in musicians. PMID:19515922
Grahn, Jessica A; Rowe, James B
2009-06-10
Little is known about the underlying neurobiology of rhythm and beat perception, despite its universal cultural importance. Here we used functional magnetic resonance imaging to study rhythm perception in musicians and nonmusicians. Three conditions varied in the degree to which external reinforcement versus internal generation of the beat was required. The "volume" condition strongly externally marked the beat with volume changes, the "duration" condition marked the beat with weaker accents arising from duration changes, and the "unaccented" condition required the beat to be entirely internally generated. In all conditions, beat rhythms compared with nonbeat control rhythms revealed putamen activity. The presence of a beat was also associated with greater connectivity between the putamen and the supplementary motor area (SMA), the premotor cortex (PMC), and auditory cortex. In contrast, the type of accent within the beat conditions modulated the coupling between premotor and auditory cortex, with greater modulation for musicians than nonmusicians. Importantly, the response of the putamen to beat conditions was not attributable to differences in temporal complexity between the three rhythm conditions. We propose that a cortico-subcortical network including the putamen, SMA, and PMC is engaged for the analysis of temporal sequences and prediction or generation of putative beats, especially under conditions that may require internal generation of the beat. The importance of this system for auditory-motor interaction and development of precisely timed movement is suggested here by its facilitation in musicians.
Efficient mucociliary transport relies on efficient regulation of ciliary beating.
Braiman, Alex; Priel, Zvi
2008-11-30
The respiratory mucociliary epithelium is a synchronized and highly effective waste-disposal system. It uses mucus as a vehicle, driven by beating cilia, to transport unwanted particles, trapped in the mucus, away from the respiratory system. The ciliary machinery can function in at least two different modes: a low rate of beating that requires only ATP, and a high rate of beating regulated by second messengers. The mucus propelling velocity is linearly dependent on ciliary beat frequency (CBF). The linear dependence implies that a substantial increase in transport efficiency requires an equally substantial rise in CBF. The ability to enhance beating in response to various physiological cues is a hallmark of mucociliary cells. An intricate signaling network controls ciliary activity, which relies on interplay between calcium and cyclic nucleotide pathways.
Beating and insulting children as a risk for adult cancer, cardiac disease and asthma.
Hyland, Michael E; Alkhalaf, Ahmed M; Whalley, Ben
2013-12-01
The use of physical punishment for children is associated with poor psychological and behavioral outcomes, but the causal pathway is controversial, and the effects on later physical health unknown. We conducted a cross-sectional survey of asthma, cancer, and cardiac patients (150 in each category, 75 male) recruited from outpatient clinics and 250 healthy controls (125 male). All participants were 40-60 years old and citizens of Saudi Arabia, where the use of beating and insults is an acceptable parenting style. Demographic data and recalled frequency of beatings and insults as a child were assessed on an 8-point scale. Beating and insults were highly correlated (ρ = 0.846). Propensity score matching was used to control for demographic differences between the disease and healthy groups. After controlling for differences, more frequent beating (once or more per month) and insults were associated with a significantly increased risk for cancer (RR = 1.7), cardiac disease (RR = 1.3) and asthma (RR = 1.6), with evidence of increased risk for cancer and asthma with beating frequency of once every 6 months or more. Our results show that a threatening parenting style of beating and insults is associated with increased risk for somatic disease, possibly because this form of parenting induces stress. Our findings are consistent with previous research showing that child abuse and other early life stressors adversely affect adult somatic health, but provide evidence that the pathogenic effects occur also with chronic minor stress. A stress-inducing parenting style, even when normative, has long term adverse health consequences.
Rady, Mohamed Y; Verheijde, Joseph L
2013-03-01
The utilitarian construct of two alternative criteria of human death increases the supply of transplantable organs at the end of life. Neither the neurological criterion (heart-beating donation) nor the circulatory criterion (non-heart-beating donation) is grounded in scientific evidence but based on philosophical reasoning. A utilitarian death definition can have unintended consequences for dying Muslim patients: (1) the expedited process of determining death for retrieval of transplantable organs can lead to diagnostic errors, (2) the equivalence of brain death with human death may be incorrect, and (3) end-of-life religious values and traditional rituals may be sacrificed. Therefore, it is imperative to reevaluate the two different types and criteria of death introduced by the Resolution (Fatwa) of the Council of Islamic Jurisprudence on Resuscitation Apparatus in 1986. Although we recognize that this Fatwa was based on best scientific evidence available at that time, more recent evidence shows that it rests on outdated knowledge and understanding of the phenomenon of human death. We recommend redefining death in Islam to reaffirm the singularity of this biological phenomenon as revealed in the Quran 14 centuries ago.
Robust adaptive precision motion control of hydraulic actuators with valve dead-zone compensation.
Deng, Wenxiang; Yao, Jianyong; Ma, Dawei
2017-09-01
This paper addresses the high performance motion control of hydraulic actuators with parametric uncertainties, unmodeled disturbances and unknown valve dead-zone. By constructing a smooth dead-zone inverse, a robust adaptive controller is proposed via backstepping method, in which adaptive law is synthesized to deal with parametric uncertainties and a continuous nonlinear robust control law to suppress unmodeled disturbances. Since the unknown dead-zone parameters can be estimated by adaptive law and then the effect of dead-zone can be compensated effectively via inverse operation, improved tracking performance can be expected. In addition, the disturbance upper bounds can also be updated online by adaptive laws, which increases the controller operability in practice. The Lyapunov based stability analysis shows that excellent asymptotic output tracking with zero steady-state error can be achieved by the developed controller even in the presence of unmodeled disturbance and unknown valve dead-zone. Finally, the proposed control strategy is experimentally tested on a servovalve controlled hydraulic actuation system subjected to an artificial valve dead-zone. Comparative experimental results are obtained to illustrate the effectiveness of the proposed control scheme. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Factors Affecting the Occurrence of Spinal Reflexes in Brain Dead Cases.
Hosseini, Mahsa Sadat; Ghorbani, Fariba; Ghobadi, Omid; Najafizadeh, Katayoun
2015-08-01
Brain death is defined as the permanent absence of all cortical and brain stem reflexes. A wide range of spontaneous or reflex movements that are considered medullary reflexes are observed in heart beating cases that appear brain dead, which may create uncertainty about the diagnosis of brain death and cause delays in deceased-donor organ donation process. We determined the frequency and type of medullary reflexes and factors affecting their occurrence in brain dead cases. During 1 year, 122 cases who fulfilled the criteria for brain death were admitted to the special intensive care unit for organ procurement of Masih Daneshvari Hospital. Presence of spinal reflexes was evaluated by trained coordinators and was recorded in a form in addition to other information including demographic characteristics, cause of brain death, time from detection of brain death, history of craniotomy, vital signs, serum electrolyte levels, and parameters of arterial blood gas determination. Most cases (63%) included in this study were male, and mean age was 33 ± 15 y. There was > 1 spinal reflex observed in 40 cases (33%). The most frequent reflex was plantar response (17%) following by myoclonus (10%), triple flexion reflex (9%), pronator extension reflex (8%), and undulating toe reflex (7%). Mean systolic blood pressure was significantly higher in cases who exhibited medullary reflexes than other cases (126 ± 19 mm Hg vs 116 ± 17 mm Hg; P = .007). Spinal reflexes occur frequently in brain dead cases, especially when they become hemodynamically stable after treatment in the organ procurement unit. Observing these movements by caregivers and family members has a negative effect on obtaining family consent and organ donation. Increasing awareness about spinal reflexes is necessary to avoid suspicion about the brain death diagnosis and delays in organ donation.
Bouwer, Fleur L; Werner, Carola M; Knetemann, Myrthe; Honing, Henkjan
2016-05-01
Beat perception is the ability to perceive temporal regularity in musical rhythm. When a beat is perceived, predictions about upcoming events can be generated. These predictions can influence processing of subsequent rhythmic events. However, statistical learning of the order of sounds in a sequence can also affect processing of rhythmic events and must be differentiated from beat perception. In the current study, using EEG, we examined the effects of attention and musical abilities on beat perception. To ensure we measured beat perception and not absolute perception of temporal intervals, we used alternating loud and soft tones to create a rhythm with two hierarchical metrical levels. To control for sequential learning of the order of the different sounds, we used temporally regular (isochronous) and jittered rhythmic sequences. The order of sounds was identical in both conditions, but only the regular condition allowed for the perception of a beat. Unexpected intensity decrements were introduced on the beat and offbeat. In the regular condition, both beat perception and sequential learning were expected to enhance detection of these deviants on the beat. In the jittered condition, only sequential learning was expected to affect processing of the deviants. ERP responses to deviants were larger on the beat than offbeat in both conditions. Importantly, this difference was larger in the regular condition than in the jittered condition, suggesting that beat perception influenced responses to rhythmic events in addition to sequential learning. The influence of beat perception was present both with and without attention directed at the rhythm. Moreover, beat perception as measured with ERPs correlated with musical abilities, but only when attention was directed at the stimuli. Our study shows that beat perception is possible when attention is not directed at a rhythm. In addition, our results suggest that attention may mediate the influence of musical abilities on beat perception. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Liu, Yan-Jun; Gao, Ying; Tong, Shaocheng; Chen, C L Philip
2016-01-01
In this paper, an effective adaptive control approach is constructed to stabilize a class of nonlinear discrete-time systems, which contain unknown functions, unknown dead-zone input, and unknown control direction. Different from linear dead zone, the dead zone, in this paper, is a kind of nonlinear dead zone. To overcome the noncausal problem, which leads to the control scheme infeasible, the systems can be transformed into a m -step-ahead predictor. Due to nonlinear dead-zone appearance, the transformed predictor still contains the nonaffine function. In addition, it is assumed that the gain function of dead-zone input and the control direction are unknown. These conditions bring about the difficulties and the complicacy in the controller design. Thus, the implicit function theorem is applied to deal with nonaffine dead-zone appearance, the problem caused by the unknown control direction can be resolved through applying the discrete Nussbaum gain, and the neural networks are used to approximate the unknown function. Based on the Lyapunov theory, all the signals of the resulting closed-loop system are proved to be semiglobal uniformly ultimately bounded. Moreover, the tracking error is proved to be regulated to a small neighborhood around zero. The feasibility of the proposed approach is demonstrated by a simulation example.
The role of the autonomic nervous system in the resting tachycardia of human hyperthyroidism.
Maciel, B C; Gallo, L; Marin Neto, J A; Maciel, L M; Alves, M L; Paccola, G M; Iazigi, N
1987-02-01
The mechanisms that control resting heart rate in hyperthyroidism were evaluated in six patients before and after treatment with propylthiouracil. The patients were subjected to pharmacological blockade under resting conditions in two experimental sessions: first session, propranolol (0.2 mg/kg body weight); second session, atropine (0.04 mg/kg body weight) followed by propranolol (0.2 mg/kg body weight). All drugs were administered intravenously. Resting heart rate was significantly reduced from 100 +/- 6.5 beats/min to 72 +/- 2.5 beats/min (P less than 0.005) after clinical and laboratory control of the disease. After double blockade, intrinsic heart rate was reduced from 105 +/- 6.8 beats/min before treatment to 98 +/- 6.0 beats/min after treatment (P less than 0.025). The reduction in heart rate caused by propranolol was not significantly different before (-13 +/- 1.4 beats/min) and after (-9 +/- 1.0 beats/min) propylthiouracil. In contrast, atropine induced a higher elevation of heart rate after treatment (45 +/- 8.6 beats/min) than before treatment (26 +/- 4.0 beats/min). The present results suggest no appreciable participation of the sympathetic component of the autonomic nervous system in the tachycardia of hyperthyroidism, at least under the conditions of the present study. The small change observed in intrinsic heart rate, although significant, seems to indicate that this is not the most important mechanism involved in this tachycardia. Our results suggest that an important reduction in the efferent activity of the parasympathetic component participates in the mechanisms that modify resting heart rte in hyperthyroidism.
Closed-loop control of zebrafish response using a bioinspired robotic-fish in a preference test
Kopman, Vladislav; Laut, Jeffrey; Polverino, Giovanni; Porfiri, Maurizio
2013-01-01
In this paper, we study the response of zebrafish to a robotic-fish whose morphology and colour pattern are inspired by zebrafish. Experiments are conducted in a three-chambered instrumented water tank where a robotic-fish is juxtaposed with an empty compartment, and the preference of live subjects is scored as the mean time spent in the vicinity of the tank's two lateral sides. The tail-beating of the robotic-fish is controlled in real-time based on feedback from fish motion to explore a spectrum of closed-loop systems, including proportional and integral controllers. Closed-loop control systems are complemented by open-loop strategies, wherein the tail-beat of the robotic-fish is independent of the fish motion. The preference space and the locomotory patterns of fish for each experimental condition are analysed and compared to understand the influence of real-time closed-loop control on zebrafish response. The results of this study show that zebrafish respond differently to the pattern of tail-beating motion executed by the robotic-fish. Specifically, the preference and behaviour of zebrafish depend on whether the robotic-fish tail-beating frequency is controlled as a function of fish motion and how such closed-loop control is implemented. PMID:23152102
Kirkland, Megan C; Chen, Alice; Downer, Matthew B; Holloway, Brett J; Wallack, Elizabeth M; Lockyer, Evan J; Buckle, Natasha C M; Abbott, Courtney L; Ploughman, Michelle
2018-06-01
People with mild multiple sclerosis (MS) often report subtle deficits in balance and cognition but display no measurable impairment on clinical assessments. We examined whether hopping to a metronome beat had the potential to detect anticipatory motor control deficits among people with mild MS (Expanded Disability Status Scale ≤ 3.5). Participants with MS (n = 13), matched controls (n = 9), and elderly subjects (n = 13) completed tests of cognition (Montreal Cognitive Assessment (MoCA)) and motor performance (Timed 25 Foot Walk Test (T25FWT)). Participants performed two bipedal hopping tasks: at 40 beats/min (bpm) and 60-bpm in random order. Hop characteristics (length, symmetry, variability) and delay from the metronome beat were extracted from an instrumented walkway and compared between groups. The MS group became more delayed from the metronome beat over time whereas elderly subjects tended to hop closer to the beat (F = 4.52, p = 0.02). Delay of the first hop during 60-bpm predicted cognition in people with MS (R = 0.55, β = 4.64 (SD 4.63), F = 4.85, p = 0.05) but not among control (R = 0.07, p = 0.86) or elderly subjects (R = 0.17, p = 0.57). In terms of hopping characteristics, at 60-bpm, people with MS and matched controls were significantly different from the elderly group. However, at 40-bpm, the MS group was no longer significantly different from the elderly group, even though matched controls and elderly still differed significantly. This new timed hopping test may be able to detect both physical ability, and feed-forward anticipatory control impairments in people with mild MS. Hopping at a frequency of 40-bpm seemed more challenging. Several aspects of anticipatory motor control can be measured: including reaction time to the first metronome cue and the ability to adapt and anticipate the beat over time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sternkopf, Christian; Manske, Eberhard
2018-06-01
We report on the enhancement of a previously-presented heterodyne laser source on the basis of two phase-locked loop (PLL) frequency coupled internal-mirror He–Ne lasers. Our new system consists of two digitally controlled He–Ne lasers with slightly different wavelengths, and offers high-frequency stability and very narrow optical linewidth. The digitally controlled system has been realized by using a FPGA controller and transconductance amplifiers. The light of both lasers was coupled into separate fibres for heterodyne interferometer applications. To enhance the laser performance we observed the sensitivity of both laser tubes to electromagnetic noise from various laser power supplies and frequency control systems. Furthermore, we describe how the linewidth of a frequency-controlled He–Ne laser can be reduced during precise frequency stabilisation. The digitally controlled laser source reaches a standard beat frequency deviation of less than 20 Hz (with 1 s gate time) and a spectral full width at half maximum (FWHM) of the beat signal less than 3 kHz. The laser source has enough optical output power to serve a fibre-coupled multi axis heterodyne interferometer. The system can be adjusted to output beat frequencies in the range of 0.1 MHz–20 MHz.
Cruise and turning performance of an improved fish robot actuated by piezoceramic actuators
NASA Astrophysics Data System (ADS)
Nguyen, Quang Sang; Heo, Seok; Park, Hoon Cheol; Goo, Nam Seo; Byun, Doyoung
2009-03-01
The purpose of this study is improvement of a fish robot actuated by four light-weight piezocomposite actuators (LIPCAs). In the fish robot, we developed a new actuation mechanism working without any gear and thus the actuation mechanism was simple in fabrication. By using the new actuation mechanism, cross section of the fish robot became 30% smaller than that of the previous model. Performance tests of the fish robot in water were carried out to measure tail-beat angle, thrust force, swimming speed and turning radius for tail-beat frequencies from 1Hz to 5Hz. The maximum swimming speed of the fish robot was 7.7 cm/s at 3.9Hz tail-beat frequency. Turning experiment showed that swimming direction of the fish robot could be controlled with 0.41 m turning radius by controlling tail-beat angle.
High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm.
Olbers, Joakim; Gille, Adam; Ljungman, Petter; Rosenqvist, Mårten; Östergren, Jan; Witt, Nils
2018-02-07
Atrial fibrillation (AF) is associated with an increased risk for cardiovascular morbidity and mortality, not entirely explained by thromboembolism. The underlying mechanisms for this association are largely unknown. Similarly, high blood pressure (BP) increases the risk for cardiovascular events. Despite this the interplay between AF and BP is insufficiently studied. The purpose of this study was to examine and quantify the beat-to-beat blood pressure variability in patients with AF in comparison to a control group of patients with sinus rhythm. We studied 33 patients - 21 in atrial fibrillation and 12 in sinus rhythm - undergoing routine coronary angiography. Invasive blood pressure was recorded at three locations: radial artery, brachial artery and ascending aorta. Blood pressure variability, defined as average beat-to-beat blood pressure difference, was calculated for systolic and diastolic blood pressure at each site. We observed a significant difference (p < .001) in systolic and diastolic blood pressure variability between the atrial fibrillation and sinus rhythm groups at all locations. Systolic blood pressure variability roughly doubled in the atrial fibrillation group compared to the sinus rhythm group (4.9 and 2.4 mmHg respectively). Diastolic beat-to-beat blood pressure variability was approximately 6 times as high in the atrial fibrillation group compared to the sinus rhythm group (7.5 and 1.2 mmHg respectively). No significant difference in blood pressure variability was seen between measurement locations. Beat-to-beat blood pressure variability in patients with atrial fibrillation was substantially higher than in patients with sinus rhythm. Hemodynamic effects of this beat-to-beat variation in blood pressure may negatively affect vascular structure and function, which may contribute to the increased cardiovascular morbidity and mortality seen in patients with atrial fibrillation.
The effect of binaural beats on verbal working memory and cortical connectivity.
Beauchene, Christine; Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A; Leonessa, Alexander
2017-04-01
Synchronization in activated regions of cortical networks affect the brain's frequency response, which has been associated with a wide range of states and abilities, including memory. A non-invasive method for manipulating cortical synchronization is binaural beats. Binaural beats take advantage of the brain's response to two pure tones, delivered independently to each ear, when those tones have a small frequency mismatch. The mismatch between the tones is interpreted as a beat frequency, which may act to synchronize cortical oscillations. Neural synchrony is particularly important for working memory processes, the system controlling online organization and retention of information for successful goal-directed behavior. Therefore, manipulation of synchrony via binaural beats provides a unique window into working memory and associated connectivity of cortical networks. In this study, we examined the effects of different acoustic stimulation conditions during an N-back working memory task, and we measured participant response accuracy and cortical network topology via EEG recordings. Six acoustic stimulation conditions were used: None, Pure Tone, Classical Music, 5 Hz binaural beats, 10 Hz binaural beats, and 15 Hz binaural beats. We determined that listening to 15 Hz binaural beats during an N-Back working memory task increased the individual participant's accuracy, modulated the cortical frequency response, and changed the cortical network connection strengths during the task. Only the 15 Hz binaural beats produced significant change in relative accuracy compared to the None condition. Listening to 15 Hz binaural beats during the N-back task activated salient frequency bands and produced networks characterized by higher information transfer as compared to other auditory stimulation conditions.
McConnell, Patrick A; Froeliger, Brett; Garland, Eric L; Ives, Jeffrey C; Sforzo, Gary A
2014-01-01
Binaural beats are an auditory illusion perceived when two or more pure tones of similar frequencies are presented dichotically through stereo headphones. Although this phenomenon is thought to facilitate state changes (e.g., relaxation), few empirical studies have reported on whether binaural beats produce changes in autonomic arousal. Therefore, the present study investigated the effects of binaural beating on autonomic dynamics [heart rate variability (HRV)] during post-exercise relaxation. Subjects (n = 21; 18-29 years old) participated in a double-blind, placebo-controlled study during which binaural beats and placebo were administered over two randomized and counterbalanced sessions (within-subjects repeated-measures design). At the onset of each visit, subjects exercised for 20-min; post-exercise, subjects listened to either binaural beats ('wide-band' theta-frequency binaural beats) or placebo (carrier tones) for 20-min while relaxing alone in a quiet, low-light environment. Dependent variables consisted of high-frequency (HF, reflecting parasympathetic activity), low-frequency (LF, reflecting sympathetic and parasympathetic activity), and LF/HF normalized powers, as well as self-reported relaxation. As compared to the placebo visit, the binaural-beat visit resulted in greater self-reported relaxation, increased parasympathetic activation and increased sympathetic withdrawal. By the end of the 20-min relaxation period there were no observable differences in HRV between binaural-beat and placebo visits, although binaural-beat associated HRV significantly predicted subsequent reported relaxation. Findings suggest that listening to binaural beats may exert an acute influence on both LF and HF components of HRV and may increase subjective feelings of relaxation.
Cardiac autonomic denervation in Parkinson's disease is linked to REM sleep behavior disorder.
Postuma, Ronald B; Montplaisir, Jacques; Lanfranchi, Paola; Blais, Hélène; Rompré, Sylvie; Colombo, Roberto; Gagnon, Jean-François
2011-07-01
Recent studies have suggested a close connection between autonomic dysfunction and rapid eye movement sleep behavior disorder, which differs in nature from other early-stage markers of Parkinson's disease. In this study we examined the relationship between rapid eye movement sleep behavior disorder and autonomic dysfunction in Parkinson's disease as measured by cardiac beat-to-beat variability. In 53 patients with Parkinson's disease and 36 controls, electrocardiographic trace from a polysomnogram was assessed for measures of beat-to-beat RR variability including RR-standard deviation and frequency domains (low- and high-frequency components). Results were compared between patients with Parkinson's disease and controls, and between patients with Parkinson's disease with and without rapid eye movement sleep behavior disorder. On numerous cardiac autonomic measures, patients with Parkinson's disease showed clear abnormalities compared with controls. However, these abnormalities were confined only to those patients with associated rapid eye movement sleep behavior; those without were not different than controls. As with other clinical autonomic variables, cardiac autonomic denervation is predominantly associated not with Parkinson's disease itself, but with the presence of rapid eye movement sleep behavior disorder. Copyright © 2011 Movement Disorder Society.
Unified dead-time compensation structure for SISO processes with multiple dead times.
Normey-Rico, Julio E; Flesch, Rodolfo C C; Santos, Tito L M
2014-11-01
This paper proposes a dead-time compensation structure for processes with multiple dead times. The controller is based on the filtered Smith predictor (FSP) dead-time compensator structure and it is able to control stable, integrating, and unstable processes with multiple input/output dead times. An equivalent model of the process is first computed in order to define the predictor structure. Using this equivalent model, the primary controller and the predictor filter are tuned to obtain an internally stable closed-loop system which also attempts some closed-loop specifications in terms of set-point tracking, disturbance rejection, and robustness. Some simulation case studies are used to illustrate the good properties of the proposed approach. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Hu, Mandy X; Lamers, Femke; de Geus, Eco J C; Penninx, Brenda W J H
2016-06-01
It remains unclear whether depressive and anxiety disorders are associated with hyporeactivity or hyperreactivity of the autonomic nervous system (ANS) and whether deviant reactivity occurs in all types of stressors. This study compared ANS reactivity in people with current or remitted depression/anxiety with reactivity in healthy controls during two stress conditions. From the Netherlands Study of Depression and Anxiety, data of 804 individuals with current depression/anxiety, 913 individuals with remitted depression/anxiety, and 466 healthy controls (mean age = 44.1 years; 66.4% female) were available. Two conditions were used to evoke stress: a) an n-back task, a cognitively challenging stressor, and 2) a psychiatric interview, evoking personal-emotional stress related to the occurrence of symptoms of depression/anxiety. Indicators of ANS activity were heart rate (HR), root mean square of differences between successive interbeat intervals (RMSSD), respiratory sinus arrhythmia (RSA), and preejection period. As compared with controls, participants with psychopathology had significant hyporeactivity of HR (controls = 4.1 ± 4.2 beats/min; remitted = 3.5 ± 3.5 beats/min; current psychopathology = 3.1 ± 3.4 beats/min), RMSSD (controls = -6.2 ± 14.5 milliseconds; remitted = -5.4 ± 17.8 milliseconds; current psychopathology = -3.5 ± 15.4 milliseconds), and RSA (controls = -9.3 ± 17.0 milliseconds; remitted = -7.4 ± 16.5 milliseconds; current psychopathology = -6.9 ± 15.0 milliseconds) during the n-back task. In contrast, during the psychiatric interview, they showed significant hyperreactivity of HR (controls = 2.7 ± 3.4 beats/min; remitted = 3.5 ± 3.4 beats/min; current psychopathology = 4.0 ± 3.3 beats/min), RMSSD (controls = -3.4 ± 12.2 milliseconds; remitted = -4.1 ± 12.1 milliseconds; current psychopathology = -5.6 ± 11.8 milliseconds), and RSA (controls = -3.8 ± 8.1 milliseconds; remitted = -4.3 ± 7.9 milliseconds; current psychopathology = -5.0 ± 7.9 milliseconds). The lack of group differences in preejection period reactivity suggests that the found effects were driven by altered cardiac vagal reactivity in depression/anxiety. The direction of altered ANS reactivity in depressed/anxious patients is dependent on the type of stressor, and only the more ecologically valid stressors may evoke hyperreactivity in these patients.
Energy status of pig donor organs after ischemia is independent of donor type.
Stadlbauer, Vanessa; Stiegler, Philipp; Taeubl, Philipp; Sereinigg, Michael; Puntschart, Andreas; Bradatsch, Andrea; Curcic, Pero; Seifert-Held, Thomas; Zmugg, Gerda; Stojakovic, Tatjana; Leopold, Barbara; Blattl, Daniela; Horki, Vera; Mayrhauser, Ursula; Wiederstein-Grasser, Iris; Leber, Bettina; Jürgens, Günther; Tscheliessnigg, Karlheinz; Hallström, Seth
2013-04-01
Literature is controversial whether organs from living donors have a better graft function than brain dead (BD) and non-heart-beating donor organs. Success of transplantation has been correlated with high-energy phosphate (HEP) contents of the graft. HEP contents in heart, liver, kidney, and pancreas from living, BD, and donation after cardiac death in a pig model (n=6 per donor type) were evaluated systematically. BD was induced under general anesthesia by inflating a balloon in the epidural space. Ten hours after confirmation, organs were retrieved. Cardiac arrest was induced by 9V direct current. After 10min of ventricular fibrillation without cardiac output, mechanical and medical reanimation was performed for 30min before organ retrieval. In living donors, organs were explanted immediately. Freeze-clamped biopsies were taken before perfusion with Celsior solution (heart) or University of Wisconsin solution (abdominal organs) in BD and living donors or with Histidine-Tryptophan-Ketoglutaric solution (all organs) in non-heart-beating donors, after perfusion, and after cold ischemia (4h for heart, 6h for liver and pancreas, and 12h for kidney). HEPs (adenosine triphosphate, adenosine diphosphate, adenosine monophosphate, and phosphocreatine), xanthine, and hypoxanthine were measured by high-performance liquid chromatography. Energy charge and adenosine triphosphate-to-adenosine diphosphate ratio were calculated. After ischemia, organs from different donor types showed no difference in energy status. In all organs, a decrease of HEP and an increase in hypoxanthine contents were observed during perfusion and ischemia, irrespective of the donor type. Organs from BD or non-heart-beating donors do not differ from living donor organs in their energy status after average tolerable ischemia. Copyright © 2013 Elsevier Inc. All rights reserved.
McConnell, Patrick A.; Froeliger, Brett; Garland, Eric L.; Ives, Jeffrey C.; Sforzo, Gary A.
2014-01-01
Binaural beats are an auditory illusion perceived when two or more pure tones of similar frequencies are presented dichotically through stereo headphones. Although this phenomenon is thought to facilitate state changes (e.g., relaxation), few empirical studies have reported on whether binaural beats produce changes in autonomic arousal. Therefore, the present study investigated the effects of binaural beating on autonomic dynamics [heart rate variability (HRV)] during post-exercise relaxation. Subjects (n = 21; 18–29 years old) participated in a double-blind, placebo-controlled study during which binaural beats and placebo were administered over two randomized and counterbalanced sessions (within-subjects repeated-measures design). At the onset of each visit, subjects exercised for 20-min; post-exercise, subjects listened to either binaural beats (‘wide-band’ theta-frequency binaural beats) or placebo (carrier tones) for 20-min while relaxing alone in a quiet, low-light environment. Dependent variables consisted of high-frequency (HF, reflecting parasympathetic activity), low-frequency (LF, reflecting sympathetic and parasympathetic activity), and LF/HF normalized powers, as well as self-reported relaxation. As compared to the placebo visit, the binaural-beat visit resulted in greater self-reported relaxation, increased parasympathetic activation and increased sympathetic withdrawal. By the end of the 20-min relaxation period there were no observable differences in HRV between binaural-beat and placebo visits, although binaural-beat associated HRV significantly predicted subsequent reported relaxation. Findings suggest that listening to binaural beats may exert an acute influence on both LF and HF components of HRV and may increase subjective feelings of relaxation. PMID:25452734
The effect of binaural beats on verbal working memory and cortical connectivity
NASA Astrophysics Data System (ADS)
Beauchene, Christine; Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A.; Leonessa, Alexander
2017-04-01
Objective. Synchronization in activated regions of cortical networks affect the brain’s frequency response, which has been associated with a wide range of states and abilities, including memory. A non-invasive method for manipulating cortical synchronization is binaural beats. Binaural beats take advantage of the brain’s response to two pure tones, delivered independently to each ear, when those tones have a small frequency mismatch. The mismatch between the tones is interpreted as a beat frequency, which may act to synchronize cortical oscillations. Neural synchrony is particularly important for working memory processes, the system controlling online organization and retention of information for successful goal-directed behavior. Therefore, manipulation of synchrony via binaural beats provides a unique window into working memory and associated connectivity of cortical networks. Approach. In this study, we examined the effects of different acoustic stimulation conditions during an N-back working memory task, and we measured participant response accuracy and cortical network topology via EEG recordings. Six acoustic stimulation conditions were used: None, Pure Tone, Classical Music, 5 Hz binaural beats, 10 Hz binaural beats, and 15 Hz binaural beats. Main results. We determined that listening to 15 Hz binaural beats during an N-Back working memory task increased the individual participant’s accuracy, modulated the cortical frequency response, and changed the cortical network connection strengths during the task. Only the 15 Hz binaural beats produced significant change in relative accuracy compared to the None condition. Significance. Listening to 15 Hz binaural beats during the N-back task activated salient frequency bands and produced networks characterized by higher information transfer as compared to other auditory stimulation conditions.
Closed-loop regulation of arterial pressure after acute brain death.
Soltesz, Kristian; Sjöberg, Trygve; Jansson, Tomas; Johansson, Rolf; Robertsson, Anders; Paskevicius, Audrius; Liao, Quiming; Qin, Guangqi; Steen, Stig
2018-06-01
The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is challenging, due to the lack of vasomotor function in BD donors. Closed-loop stabilization therefore has the potential of increasing availability of acceptable donor organs, and serves to indicate feasibility within less demanding patient groups. A dynamic model of nitroglycerine pharmacology, suitable for controller synthesis, was identified from an experiment involving an anesthetized pig, using a gradient-based output error method. The model was used to synthesize a robust PID controller for hypertension prevention, evaluated in a second experiment, on a second, brain dead, pig. Hypotension was simultaneously prevented using closed-loop controlled infusion of noradrenaline, by means of a previously published controller. A linear model of low order, with variable (uncertain) gain, was sufficient to describe the dynamics to be controlled. The robustly tuned PID controller utilized in the second experiment kept the MAP within a user-defined range. The system was able to prevent hypertension, exceeding a reference of 100 mmHg by more than 10%, during 98% of a 12 h experiment. This early work demonstrates feasibility of the investigated modelling and control synthesis approach, for the purpose of maintaining normotension in a porcine BD model. There remains a need to characterize individual variability, in order to ensure robust performance over the expected population.
Stapf, Daniel; Franke, Andreas; Schreckenberg, Marcus; Schummers, Georg; Mischke, Karl; Marx, Nikolaus; Schauerte, Patrick; Knackstedt, Christian
2013-04-01
Three-dimensional (3D)-imaging provides important information on cardiac anatomy during electrophysiological procedures. Real-time updates of modalities with high soft-tissue contrast are particularly advantageous during cardiac procedures. Therefore, a beat to beat 3D visualization of cardiac anatomy by intracardiac echocardiography (ICE) was developed and tested in phantoms and animals. An electronic phased-array 5-10 MHz ICE-catheter (Acuson, AcuNav/Siemens Medical Solutions USA/64 elements) providing a 90° sector image was used for ICE-imaging. A custom-made mechanical prototype controlled by a servo motor allowed automatic rotation of the ICE-catheter around its longitudinal axis. During a single heartbeat, the ICE-catheter was rotated and 2D-images were acquired. Reconstruction into a 3D volume and rendering by a prototype software was performed beat to beat. After experimental validation using a rigid phantom, the system was tested in an animal study and afterwards, for quantitative validation, in a dynamic phantom. Acquisition of beat to beat 3D-reconstruction was technically feasible. However, twisting of the ICE-catheter shaft due to friction and torsion was found and rotation was hampered. Also, depiction of catheters was not always ensured in case of parallel alignment. Using a curved sheath for depiction of cardiac anatomy there was no congruent depiction of shape and dimension of static and moving objects. Beat to beat 3D-ICE-imaging is feasible. However, shape and dimension of static and moving objects cannot always be displayed with necessary steadiness as needed in the clinical setting. As catheter depiction is also limited, clinical use seems impossible.
A High-Density EEG Investigation into Steady State Binaural Beat Stimulation
Goodin, Peter; Ciorciari, Joseph; Baker, Kate; Carrey, Anne-Marie; Harper, Michelle; Kaufman, Jordy
2012-01-01
Binaural beats are an auditory phenomenon that has been suggested to alter physiological and cognitive processes including vigilance and brainwave entrainment. Some personality traits measured by the NEO Five Factor Model have been found to alter entrainment using pulsing light stimuli, but as yet no studies have examined if this occurs using steady state presentation of binaural beats for a relatively short presentation of two minutes. This study aimed to examine if binaural beat stimulation altered vigilance or cortical frequencies and if personality traits were involved. Thirty-one participants were played binaural beat stimuli designed to elicit a response at either the Theta (7 Hz) or Beta (16 Hz) frequency bands while undertaking a zero-back vigilance task. EEG was recorded from a high-density electrode cap. No significant differences were found in vigilance or cortical frequency power during binaural beat stimulation compared to a white noise control period. Furthermore, no significant relationships were detected between the above and the Big Five personality traits. This suggests a short presentation of steady state binaural beats are not sufficient to alter vigilance or entrain cortical frequencies at the two bands examined and that certain personality traits were not more susceptible than others. PMID:22496862
A high-density EEG investigation into steady state binaural beat stimulation.
Goodin, Peter; Ciorciari, Joseph; Baker, Kate; Carey, Anne-Marie; Carrey, Anne-Marie; Harper, Michelle; Kaufman, Jordy
2012-01-01
Binaural beats are an auditory phenomenon that has been suggested to alter physiological and cognitive processes including vigilance and brainwave entrainment. Some personality traits measured by the NEO Five Factor Model have been found to alter entrainment using pulsing light stimuli, but as yet no studies have examined if this occurs using steady state presentation of binaural beats for a relatively short presentation of two minutes. This study aimed to examine if binaural beat stimulation altered vigilance or cortical frequencies and if personality traits were involved. Thirty-one participants were played binaural beat stimuli designed to elicit a response at either the Theta (7 Hz) or Beta (16 Hz) frequency bands while undertaking a zero-back vigilance task. EEG was recorded from a high-density electrode cap. No significant differences were found in vigilance or cortical frequency power during binaural beat stimulation compared to a white noise control period. Furthermore, no significant relationships were detected between the above and the Big Five personality traits. This suggests a short presentation of steady state binaural beats are not sufficient to alter vigilance or entrain cortical frequencies at the two bands examined and that certain personality traits were not more susceptible than others.
Load Response of the Flagellar Beat
NASA Astrophysics Data System (ADS)
Klindt, Gary S.; Ruloff, Christian; Wagner, Christian; Friedrich, Benjamin M.
2016-12-01
Cilia and flagella exhibit regular bending waves that perform mechanical work on the surrounding fluid, to propel cellular swimmers and pump fluids inside organisms. Here, we quantify a force-velocity relationship of the beating flagellum, by exposing flagellated Chlamydomonas cells to controlled microfluidic flows. A simple theory of flagellar limit-cycle oscillations, calibrated by measurements in the absence of flow, reproduces this relationship quantitatively. We derive a link between the energy efficiency of the flagellar beat and its ability to synchronize to oscillatory flows.
Howarth, F C; Jacobson, M; Shafiullah, M; Adeghate, E
2005-11-01
In vivo biotelemetry studies have demonstrated that short-term streptozotocin (STZ)-induced diabetes is associated with a reduction in heart rate (HR) and heart rate variability (HRV) and prolongation of QT and QRS intervals. This study investigates the long-term effects of STZ-induced diabetes on the electrocardiogram (ECG), physical activity and body temperature. Transmitter devices were surgically implanted in the peritoneal cavity of young adult male Wistar rats. Electrodes from the transmitter were arranged in Einthoven bipolar lead II configuration. ECG, physical activity and body temperature data were continuously recorded with a telemetry system before and following the administration of STZ (60 mg kg(-1)) for a period of 22 weeks. HR, physical activity and body temperature declined rapidly 3-5 days after the administration of STZ. The effects became conspicuous with time reaching a new steady state approximately 1-2 weeks after STZ treatment. HR at 4 weeks was 268 +/- 5 beats min(-1) in diabetic rats compared to 347 +/- 12 beats min(-1) in age-matched controls. HRV at 4 weeks was also significantly reduced after STZ treatment (18 +/- 3 beats min(-1)) compared to controls (33 +/- 3 beats min(-1)). HR and HRV were not additionally altered in either diabetic rats (266 +/- 5 and 20 +/- 4 beats min(-1)) or age-matched controls (316 +/- 6 and 25 +/- 4 beats min(-1)) at 22 weeks. Reduced physical activity and/or body temperature may partly underlie the reductions in HR and HRV. In addition, the increased power spectral low frequency/high frequency ratio from 4 weeks after STZ treatment may indicate an accompanying disturbance in sympathovagal balance.
Slater, Jessica; Ashley, Richard; Tierney, Adam; Kraus, Nina
2018-01-01
Musical rhythm engages motor and reward circuitry that is important for cognitive control, and there is evidence for enhanced inhibitory control in musicians. We recently revealed an inhibitory control advantage in percussionists compared with vocalists, highlighting the potential importance of rhythmic expertise in mediating this advantage. Previous research has shown that better inhibitory control is associated with less variable performance in simple sensorimotor synchronization tasks; however, this relationship has not been examined through the lens of rhythmic expertise. We hypothesize that the development of rhythm skills strengthens inhibitory control in two ways: by fine-tuning motor networks through the precise coordination of movements "in time" and by activating reward-based mechanisms, such as predictive processing and conflict monitoring, which are involved in tracking temporal structure in music. Here, we assess adult percussionists and nonpercussionists on inhibitory control, selective attention, basic drumming skills (self-paced, paced, and continuation drumming), and cortical evoked responses to an auditory stimulus presented on versus off the beat of music. Consistent with our hypotheses, we find that better inhibitory control is correlated with more consistent drumming and enhanced neural tracking of the musical beat. Drumming variability and the neural index of beat alignment each contribute unique predictive power to a regression model, explaining 57% of variance in inhibitory control. These outcomes present the first evidence that enhanced inhibitory control in musicians may be mediated by rhythmic expertise and provide a foundation for future research investigating the potential for rhythm-based training to strengthen cognitive function.
Balaban, Cecilia Lucía; Rodríguez, Joaquín Valentín; Tiribelli, Claudio; Guibert, Edgardo Elvio
2015-08-01
Liver transplantation is currently the preferred treatment option for end-stage liver disease. Donation after cardiac death was a common practice in the early years of organ donation before brain death criteria were established. Those organs were subjected to variable periods of warm ischemia that might intensify cold ischemia/reperfusion injuries. In the present, shortage of brain dead donors has led to the reassessment of organ donation after cardiac death. Since many cytoprotective roles have been describe for H2S during ischemia/reperfusion on a variety of tissues, we hypothesized that graft exposure to this bioactive gas might improve preservation of non-heart beating donated organs. Therefore, to establish a rat model of donation post-cardiac arrest and using this approach to judge H2S delivery effects on graft hypothermic preservation, were the main objectives of this investigation. Cardiopulmonary arrest was induced in sedated rats by overload of potassium (K(+)). Livers were surgically removed and subsequently stored in HTK Solution (Histidine-tryptophan-ketoglutarate) at 0-4°C. After 24 h of hypothermic preservation, livers were rewarmed in an ex vivo model. Three experimental groups were established as follows: I--Livers procured before cardiac death and cold stored 24 h in HTK (BCD); II--Livers procured after cardiac death (45 min) and cold stored 24 h in HTK (ACD); III--Livers procured after cardiac death (45 min) and cold stored 24 h in HTK+10 μM Sodium Sulfide (Na2S) (ACD-SS). Data suggest that after 45 min of warm ischemia, viability parameters assessed during reperfusion in the ex vivo model were significantly impaired. Real time PCR revealed that after ex vivo reperfusion there is an increased expression of HO-1 and TNF-α and a modest drop in Bcl-2 mRNA, which could be interpreted as the cellular response to the hypoxic insult sustained during warm ischemia. On the other hand, warm ischemic livers exposed to H2S during cold storage, improved microcirculation, morphology and viability parameters during ex vivo reperfusion and showed significant modulation of HO-1 mRNA expression. In conclusion, HTK supplementation with Na2S arose as a potential treatment to recover non-heart beating harvested organs. Furthermore, an appropriate model of cardiac dead liver donors was successfully developed. Copyright © 2015 Elsevier Inc. All rights reserved.
Miniature Surface Plasmon Polariton Amplitude Modulator by Beat Frequency and Polarization Control
Chang, Cheng-Wei; Lin, Chu-En; Yu, Chih-Jen; Yeh, Ting-Tso; Yen, Ta-Jen
2016-01-01
The miniaturization of modulators keeps pace for the compact devices in optical applications. Here, we present a miniature surface plasmon polariton amplitude modulator (SPPAM) by directing and interfering surface plasmon polaritons on a nanofabricated chip. Our results show that this SPPAM enables two kinds of modulations. The first kind of modulation is controlled by encoding angular-frequency difference from a Zeeman laser, with a beat frequency of 1.66 MHz; the second of modulation is validated by periodically varying the polarization states from a polarization generator, with rotation frequencies of 0.5–10 k Hz. In addition, the normalized extinction ratio of our plasmonic structure reaches 100. Such miniaturized beat-frequency and polarization-controlled amplitude modulators open an avenue for the exploration of ultrasensitive nanosensors, nanocircuits, and other integrated nanophotonic devices. PMID:27558516
Differential baroreflex control of heart rate in sedentary and aerobically fit individuals
NASA Technical Reports Server (NTRS)
Smith, S. A.; Querry, R. G.; Fadel, P. J.; Welch-O'Connor, R. M.; Olivencia-Yurvati, A.; Shi, X.; Raven, P. B.
2000-01-01
PURPOSE: We compared arterial, aortic, and carotid-cardiac baroreflex sensitivity in eight average fit (maximal oxygen uptake, VO2max = 42.2+/-1.9 mL x kg(-1) x min(-1)) and eight high fit (VO2max = 61.9+/-2.2 mL x kg(-1) x min(-1)) healthy young adults. METHODS: Arterial and aortic (ABR) baroreflex functions were assessed utilizing hypo- and hyper-tensive challenges induced by graded bolus injections of sodium nitroprusside (SN) and phenylephrine (PE), respectively. Carotid baroreflex (CBR) sensitivity was determined using ramped 5-s pulses of both pressure and suction delivered to the carotid sinus via a neck chamber collar, independent of drug administration. RESULTS: During vasoactive drug injection, mean arterial pressure (MAP) was similarly altered in average fit (AF) and high fit (HF) groups. However, the heart rate (HR) response range of the arterial baroreflex was significantly attenuated (P < 0.05) in HF (31+/-4 beats x min(-1)) compared with AF individuals (46+/-4 beats x min(-1)). When sustained neck suction and pressure were applied to counteract altered carotid sinus pressure during SN and PE administration, isolating the ABR response, the response range remained diminished (P < 0.05) in the HF population (24+/-3 beats x min(-1)) compared with the AF group (41+/-4 beats x min(-1)). During CBR perturbation, the HF (14+/-1 beats-min(-1)) and AF (16+/-1 beats-min(-1)) response ranges were similar. The arterial baroreflex response range was significantly less than the simple sum of the CBR and ABR (HF, 38+/-3 beats x min(-1) and AF, 57+/-4 beats x min(-1)) in both fitness groups. CONCLUSIONS: These data confirm that reductions in arterial-cardiac reflex sensitivity are mediated by diminished ABR function. More importantly, these data suggest that the integrative relationship between the ABR and CBR contributing to arterial baroreflex control of HR is inhibitory in nature and not altered by exercise training.
Hombach, V; Kebbel, U; Höpp, H W; Winter, U; Hirche, H
1984-08-01
We have developed a new high resolution ECG equipment for recording cardiac microvolt potentials from the body surface. Noise reduction has been achieved by specially designed suction electrodes, by spatial averaging of the electrocardiograms from four electrode pairs, using extremely low noise amplifiers, by performing registrations within a Faraday cage, and by teaching the patient to relax during end expiratory breath holding. Fourteen young males (controls) and 30 patients with various cardiac diseases (27 with CHD) were studied. In normals ventricular late potentials were not seen, but in 12/30 patients clearcut diastolic potentials were found. In 7/12 patients with positive findings, late potentials appeared beat-by-beat, in 5/12 patients those signals occurred intermittently, in 11/30 patients questionably, and in the remaining 5/30 patients no late potentials were recorded. One patient with the Romano-Ward syndrome revealed phases with stable beat-by-beat and intermittently occurring ventricular late potentials. These results demonstrate the feasibility of continuous non-invasive recording of ventricular late potentials, whose clinical and prognostic significance remains to be established.
Psychoacoustic Factors in Musical Intonation: Beats, Interval Tuning, and Inharmonicity.
NASA Astrophysics Data System (ADS)
Keislar, Douglas Fleming
Three psychoacoustic experiments were conducted using musically experienced subjects. In the first two experiments, the interval tested was the perfect fifth F4-C5; in the final one it was the major third F4-A4. The beat rate was controlled by two different methods: (1) simply retuning the interval, and (2) frequency-shifting one partial of each pair of beating partials without changing the overall interval tuning. The second method introduces inharmonicity. In addition, two levels of beat amplitude were introduced by using either a complete spectrum of 16 equal-amplitude partials per note, or by deleting one partial from each pair of beating partials. The results of all three experiments indicate that, for these stimuli, beating does not contribute significantly to the percept of "out-of-tuneness," because it made no difference statistically whether the beat amplitude was maximal or minimal. By contrast, mistuning the interval was highly significant. For the fifths, frequency-shifting the appropriate partials had about as much effect on the perceived intonation as mistuning the interval. For thirds, this effect was weaker, presumably since there were fewer inharmonic partials and they were higher in the harmonic series. Subjects were less consistent in their judgments of thirds than of fifths, perhaps because the equal-tempered and just thirds differ noticeably, unlike fifths. Since it is unlikely that beats would be more audible in real musical situations than under these laboratory conditions, these results suggest that the perception of intonation in music is dependent on the actual interval tuning rather than the concomitant beat rate. If beating partials are unimportant vis-a-vis interval tuning, this strengthens the argument for a cultural basis for musical intonation and scales, as opposed to the acoustical basis set forth by Helmholtz and others.
Simulation of Simple Controlled Processes with Dead-Time.
ERIC Educational Resources Information Center
Watson, Keith R.; And Others
1985-01-01
The determination of closed-loop response of processes containing dead-time is typically not covered in undergraduate process control, possibly because the solution by Laplace transforms requires the use of Pade approximation for dead-time, which makes the procedure lengthy and tedious. A computer-aided method is described which simplifies the…
Shemer, Natan; Degani, Amir
2017-08-04
This work demonstrates a simple, once per step, flight-control method for robots running on a planar unknown rough-terrain environment. The robot used to exemplify these control strategies is the ParkourBot, a spring loaded inverted pendulum (SLIP)-based robot. The SLIP model is widely used for the description of humans and animals running motion and has been the basis for many robots. A known control scheme for increasing robustness of the conservative, SLIP model is the swing leg retraction (SLR) method. Despite of the SLR's popularity, it is not intended to be used on the more realistic, non-conservative damped SLIP model. On the damped SLIP model, the SLR controller failed to provide adequate results, therefore, we have derived a new simple, flight-phase control method called polynomial energy insertion (PEI). The new PEI method is based on the dead-beat solution of the damped simplified instantaneous SLIP (iSLIP) model, which assumes an infinitely stiff spring. Unlike the SLR which, starting from apex, changes the leg angle monotonically during flight, the PEI requires the leg length (hence, energy insertion) to change monotonically throughout the flight phase. Interestingly, the leg angle remains nearly constant. In simulations and experiments, we have compared the newly developed PEI to the previous SLR method. We have found that since the SLR does not control the horizontal velocity, it looses its stability under rough terrain. The PEI method was able to control the horizontal velocity and height from ground and hence showed great improvement in robustness to rough terrain. Moreover, in both simulations and experiments the PEI methods showed an increase in the mean jumps to failure of more than 30% compared to SLR-based controllers.
Human auditory steady state responses to binaural and monaural beats.
Schwarz, D W F; Taylor, P
2005-03-01
Binaural beat sensations depend upon a central combination of two different temporally encoded tones, separately presented to the two ears. We tested the feasibility to record an auditory steady state evoked response (ASSR) at the binaural beat frequency in order to find a measure for temporal coding of sound in the human EEG. We stimulated each ear with a distinct tone, both differing in frequency by 40Hz, to record a binaural beat ASSR. As control, we evoked a beat ASSR in response to both tones in the same ear. We band-pass filtered the EEG at 40Hz, averaged with respect to stimulus onset and compared ASSR amplitudes and phases, extracted from a sinusoidal non-linear regression fit to a 40Hz period average. A 40Hz binaural beat ASSR was evoked at a low mean stimulus frequency (400Hz) but became undetectable beyond 3kHz. Its amplitude was smaller than that of the acoustic beat ASSR, which was evoked at low and high frequencies. Both ASSR types had maxima at fronto-central leads and displayed a fronto-occipital phase delay of several ms. The dependence of the 40Hz binaural beat ASSR on stimuli at low, temporally coded tone frequencies suggests that it may objectively assess temporal sound coding ability. The phase shift across the electrode array is evidence for more than one origin of the 40Hz oscillations. The binaural beat ASSR is an evoked response, with novel diagnostic potential, to a signal that is not present in the stimulus, but generated within the brain.
The structure of a cholesterol-trapping protein
Date February 28, 2003 Date Berkeley Lab Science Beat Berkeley Lab Science Beat The structure of a Institute researchers determined the three-dimensional structure of a protein that controls cholesterol level in the bloodstream. Knowing the structure of the protein, a cellular receptor that ensnares
Beat note stabilization of a 10-60 GHz dual-polarization microlaser through optical down conversion.
Rolland, A; Brunel, M; Loas, G; Frein, L; Vallet, M; Alouini, M
2011-02-28
Down-conversion of a high-frequency beat note to an intermediate frequency is realized by a Mach-Zehnder intensity modulator. Optically-carried microwave signals in the 10-60 GHz range are synthesized by using a two-frequency solid-state microchip laser as a voltage-controlled oscillator inside a digital phase-locked loop. We report an in-loop relative frequency stability better than 2.5×10⁻¹¹. The principle is applicable to beat notes in the millimeter-wave range.
The impact of binaural beats on creativity
Reedijk, Susan A.; Bolders, Anne; Hommel, Bernhard
2013-01-01
Human creativity relies on a multitude of cognitive processes, some of which are influenced by the neurotransmitter dopamine. This suggests that creativity could be enhanced by interventions that either modulate the production or transmission of dopamine directly, or affect dopamine-driven processes. In the current study we hypothesized that creativity can be influenced by means of binaural beats, an auditory illusion that is considered a form of cognitive entrainment that operates through stimulating neuronal phase locking. We aimed to investigate whether binaural beats affect creative performance at all, whether they affect divergent thinking, convergent thinking, or both, and whether possible effects may be mediated by the individual striatal dopamine level. Binaural beats were presented at alpha and gamma frequency. Participants completed a divergent and a convergent thinking task to assess two important functions of creativity, and filled out the Positive And Negative Affect Scale—mood State questionnaire (PANAS-S) and an affect grid to measure current mood. Dopamine levels in the striatum were estimated using spontaneous eye blink rates (EBRs). Results showed that binaural beats, regardless of the presented frequency, can affect divergent but not convergent thinking. Individuals with low EBRs mostly benefitted from alpha binaural beat stimulation, while individuals with high EBRs were unaffected or even impaired by both alpha and gamma binaural beats. This suggests that binaural beats, and possibly other forms of cognitive entrainment, are not suited for a one-size-fits-all approach, and that individual cognitive-control systems need to be taken into account when studying cognitive enhancement methods. PMID:24294202
The impact of binaural beats on creativity.
Reedijk, Susan A; Bolders, Anne; Hommel, Bernhard
2013-01-01
Human creativity relies on a multitude of cognitive processes, some of which are influenced by the neurotransmitter dopamine. This suggests that creativity could be enhanced by interventions that either modulate the production or transmission of dopamine directly, or affect dopamine-driven processes. In the current study we hypothesized that creativity can be influenced by means of binaural beats, an auditory illusion that is considered a form of cognitive entrainment that operates through stimulating neuronal phase locking. We aimed to investigate whether binaural beats affect creative performance at all, whether they affect divergent thinking, convergent thinking, or both, and whether possible effects may be mediated by the individual striatal dopamine level. Binaural beats were presented at alpha and gamma frequency. Participants completed a divergent and a convergent thinking task to assess two important functions of creativity, and filled out the Positive And Negative Affect Scale-mood State questionnaire (PANAS-S) and an affect grid to measure current mood. Dopamine levels in the striatum were estimated using spontaneous eye blink rates (EBRs). Results showed that binaural beats, regardless of the presented frequency, can affect divergent but not convergent thinking. Individuals with low EBRs mostly benefitted from alpha binaural beat stimulation, while individuals with high EBRs were unaffected or even impaired by both alpha and gamma binaural beats. This suggests that binaural beats, and possibly other forms of cognitive entrainment, are not suited for a one-size-fits-all approach, and that individual cognitive-control systems need to be taken into account when studying cognitive enhancement methods.
NASA Astrophysics Data System (ADS)
Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.
Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.
NASA Astrophysics Data System (ADS)
Kumar, Pawan; Parmananda, P.
2018-04-01
Experiments involving the Mercury Beating Heart (MBH) oscillator, exhibiting irregular (aperiodic) dynamics, are performed. In the first set of experiments, control over irregular dynamics of the MBH oscillator was obtained via a superimposed periodic voltage signal. These irregular (aperiodic) dynamics were recovered once the control was switched off. Subsequently, two MBH oscillators were coupled to attain synchronization of their aperiodic oscillations. Finally, two uncoupled MBH oscillators were subjected, repeatedly, to a common stochastic forcing, resulting in an enhancement of their mutual phase correlation.
Joint symbolic dynamics for the assessment of cardiovascular and cardiorespiratory interactions
Baumert, Mathias; Javorka, Michal; Kabir, Muammar
2015-01-01
Beat-to-beat variations in heart period provide information on cardiovascular control and are closely linked to variations in arterial pressure and respiration. Joint symbolic analysis of heart period, systolic arterial pressure and respiration allows for a simple description of their shared short-term dynamics that are governed by cardiac baroreflex control and cardiorespiratory coupling. In this review, we discuss methodology and research applications. Studies suggest that analysis of joint symbolic dynamics provides a powerful tool for identifying physiological and pathophysiological changes in cardiovascular and cardiorespiratory control. PMID:25548272
Joint symbolic dynamics for the assessment of cardiovascular and cardiorespiratory interactions.
Baumert, Mathias; Javorka, Michal; Kabir, Muammar
2015-02-13
Beat-to-beat variations in heart period provide information on cardiovascular control and are closely linked to variations in arterial pressure and respiration. Joint symbolic analysis of heart period, systolic arterial pressure and respiration allows for a simple description of their shared short-term dynamics that are governed by cardiac baroreflex control and cardiorespiratory coupling. In this review, we discuss methodology and research applications. Studies suggest that analysis of joint symbolic dynamics provides a powerful tool for identifying physiological and pathophysiological changes in cardiovascular and cardiorespiratory control.
Li, Mingjie; Zhou, Ping; Zhao, Zhicheng; Zhang, Jinggang
2016-03-01
Recently, fractional order (FO) processes with dead-time have attracted more and more attention of many researchers in control field, but FO-PID controllers design techniques available for the FO processes with dead-time suffer from lack of direct systematic approaches. In this paper, a simple design and parameters tuning approach of two-degree-of-freedom (2-DOF) FO-PID controller based on internal model control (IMC) is proposed for FO processes with dead-time, conventional one-degree-of-freedom control exhibited the shortcoming of coupling of robustness and dynamic response performance. 2-DOF control can overcome the above weakness which means it realizes decoupling of robustness and dynamic performance from each other. The adjustable parameter η2 of FO-PID controller is directly related to the robustness of closed-loop system, and the analytical expression is given between the maximum sensitivity specification Ms and parameters η2. In addition, according to the dynamic performance requirement of the practical system, the parameters η1 can also be selected easily. By approximating the dead-time term of the process model with the first-order Padé or Taylor series, the expressions for 2-DOF FO-PID controller parameters are derived for three classes of FO processes with dead-time. Moreover, compared with other methods, the proposed method is simple and easy to implement. Finally, the simulation results are given to illustrate the effectiveness of this method. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Robles-Cabrera, Adriana; Michel-Chávez, Anaclara; Callejas-Rojas, Rodolfo C; Malamud-Kessler, Caroline; Delgado, Guillermo; Estañol-Vidal, Bruno
2014-12-01
The factors that control the blood pressure are punctually regulated to keep it in reference values. These are maintained through autoregulatory mechanisms, humoral, nervous and endothelial-related. The humoral mechanisms are complex and modify the long-term blood pressure, in the other hand, the neurogenic mechanisms, are reflexive and can be observed in beat-to-beat changes of blood pressure. The nervous cardiovascular reflexes are mediated by high-pressure and low-pressure baroreceptors, as cardiovagal, cardiosympathetic and vasosympathetic. The arterial baroreceptor are stimulated when the blood volume-ejected by the ventricle distend the arterial walls. The neural discharge travels to the autonomic centers in the brain stem and the result is the modification of the heart rate and the vascular smooth muscle tone. This sudden modification is the responsible of the beat-to-beat (short-term) blood pressure variability. A review was made on the history of the physiology and experiments of the cardiovagal, cardiosympathetic and vasosympathetic baroreflexes and its influence in the short-term blood pressure variability.
Diminution of Heart Rate Variability in Bipolar Depression
Hage, Brandon; Britton, Briana; Daniels, David; Heilman, Keri; Porges, Stephen W.; Halaris, Angelos
2017-01-01
Autonomic nervous system (ANS) dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV) provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD) patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia) was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20) than controls (ln = 5.50) (p < 0.01). Baseline heart period was significantly shorter (i.e., faster heart rate) in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients. PMID:29270399
Coombes, Emma; Jones, Andy
2016-05-01
Beat the Street aims to get children more active by encouraging them to walk and cycle in their neighbourhood using tracking technology with a reward scheme. This pilot study evaluates the impact of Beat the Street on active travel to school in Norwich, UK. Eighty children 8-10 yrs were recruited via an intervention and control school. They wore an accelerometer for 7 days at baseline, mid-intervention and post-intervention (+20 weeks), and completed a travel diary. Physical activity overall was not higher at follow-up amongst intervention children compared to controls. However, there was a positive association between moderate-to-vigorous physical activity (MVPA) during school commute times and the number of days on which children touched a Beat the Street sensor. This equated to 3.46min extra daily MVPA during commute times for children who touched a sensor on 14.5 days (the mean number of days), compared to those who did not engage. We also found weekly active travel increased at the intervention school (+10.0% per child) while it decreased at the control (-7.0%), p=0.056. Further work is needed to understand how improved engagement with the intervention might impact outcomes. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Biselli, Paolo; Fricke, Kathrin; Grote, Ludger; Braun, Andrew T; Kirkness, Jason; Smith, Philip; Schwartz, Alan; Schneider, Hartmut
2018-05-01
Nasal high flow (NHF) reduces minute ventilation and ventilatory loads during sleep but the mechanisms are not clear. We hypothesised NHF reduces ventilation in proportion to physiological but not anatomical dead space.11 subjects (five controls and six chronic obstructive pulmonary disease (COPD) patients) underwent polysomnography with transcutaneous carbon dioxide (CO 2 ) monitoring under a metabolic hood. During stable non-rapid eye movement stage 2 sleep, subjects received NHF (20 L·min -1 ) intermittently for periods of 5-10 min. We measured CO 2 production and calculated dead space ventilation.Controls and COPD patients responded similarly to NHF. NHF reduced minute ventilation (from 5.6±0.4 to 4.8±0.4 L·min -1 ; p<0.05) and tidal volume (from 0.34±0.03 to 0.3±0.03 L; p<0.05) without a change in energy expenditure, transcutaneous CO 2 or alveolar ventilation. There was a significant decrease in dead space ventilation (from 2.5±0.4 to 1.6±0.4 L·min -1 ; p<0.05), but not in respiratory rate. The reduction in dead space ventilation correlated with baseline physiological dead space fraction (r 2 =0.36; p<0.05), but not with respiratory rate or anatomical dead space volume.During sleep, NHF decreases minute ventilation due to an overall reduction in dead space ventilation in proportion to the extent of baseline physiological dead space fraction. Copyright ©ERS 2018.
Binaural auditory beats affect long-term memory.
Garcia-Argibay, Miguel; Santed, Miguel A; Reales, José M
2017-12-08
The presentation of two pure tones to each ear separately with a slight difference in their frequency results in the perception of a single tone that fluctuates in amplitude at a frequency that equals the difference of interaural frequencies. This perceptual phenomenon is known as binaural auditory beats, and it is thought to entrain electrocortical activity and enhance cognition functions such as attention and memory. The aim of this study was to determine the effect of binaural auditory beats on long-term memory. Participants (n = 32) were kept blind to the goal of the study and performed both the free recall and recognition tasks after being exposed to binaural auditory beats, either in the beta (20 Hz) or theta (5 Hz) frequency bands and white noise as a control condition. Exposure to beta-frequency binaural beats yielded a greater proportion of correctly recalled words and a higher sensitivity index d' in recognition tasks, while theta-frequency binaural-beat presentation lessened the number of correctly remembered words and the sensitivity index. On the other hand, we could not find differences in the conditional probability for recall given recognition between beta and theta frequencies and white noise, suggesting that the observed changes in recognition were due to the recollection component. These findings indicate that the presentation of binaural auditory beats can affect long-term memory both positively and negatively, depending on the frequency used.
Schuler, S R; Hashemi, S M; Badal, S H
1998-05-01
This ethnographic study examined the sociocultural context of domestic violence in 6 rural villages in Bangladesh, and the prevalence of wife-beating and its association with women's empowerment in income generation programs (IGPs). Data were obtained from interviews conducted during 1990-96. Four villages had IGPs, and 2 villages did not have credit programs. Over 66% of women reported having been beaten at one time or another. In one village 87% reported beatings. 38% reported beatings in the preceding year (a range of 14-60%). Men beat their wives over trivial matters or frustrations over problems for which wives were not responsible. Beatings were attributed to mens' desire to control behavior and reassert their authority when challenged or to exploit their wives for financial gain. Some of the most severe beatings were linked with dowry. Both husbands and wives considered the beatings legitimate. The highest level of violence was in villages that were experiencing the most changes in gender roles and that had the most women contributing to family support. The lowest levels of violence were in villages with the fewest contributing to family support. Interviews, case studies, and observations yielded ambivalent evidence about the influence of credit programs on domestic violence. Credit programs have the potential to increase women's status and to disseminate anti-violence messages among both men and women.
Jahoda, Andrew; Hastings, Richard; Hatton, Chris; Cooper, Sally-Ann; Dagnan, Dave; Zhang, Ruiqi; McConnachie, Alex; McMeekin, Nicola; Appleton, Kim; Jones, Rob; Scott, Katie; Fulton, Lauren; Knight, Rosie; Knowles, Dawn; Williams, Chris; Briggs, Andrew; MacMahon, Ken; Lynn, Helen; Smith, Ian; Thomas, Gail; Melville, Craig
2017-12-01
Psychological therapies are first-line interventions for depression, but existing provision is not accessible for many adults with intellectual disabilities. We investigated the clinical and cost-effectiveness of a behavioural activation intervention (BeatIt) for people with intellectual disabilities and depression. BeatIt was compared with a guided self-help intervention (StepUp). We did a multicentre, single-blind, randomised, controlled trial with follow-up at 4 months and 12 months after randomisation. Participants aged 18 years or older, with mild to moderate intellectual disabilities and clinically significant depression were recruited from health and social care services in the UK. The primary outcome was the Glasgow Depression Scale for people with a Learning Disability (GDS-LD) score at 12 months. Analyses were done on an intention-to-treat basis. This trial is registered with ISCRTN, number ISRCTN09753005. Between Aug 8, 2013, and Sept 1, 2015, 161 participants were randomly assigned (84 to BeatIt; 77 to StepUp); 141 (88%) participants completed the trial. No group differences were found in the effects of BeatIt and StepUp based on GDS-LD scores at 12 months (12·03 [SD 7·99] GDS-LD points for BeatIt vs 12·43 [SD 7·64] GDS-LD points for StepUp; mean difference 0·26 GDS-LD points [95% CI -2·18 to 2·70]; p=0·833). Within-group improvements in GDS-LD scores occurred in both groups at 12 months (BeatIt, mean change -4·2 GDS-LD points [95% CI -6·0 to -2·4], p<0·0001; StepUp, mean change -4·5 GDS-LD points [-6·2 to -2·7], p<0·0001), with large effect sizes (BeatIt, 0·590 [95% CI 0·337-0·844]; StepUp, 0·627 [0·380-0·873]). BeatIt was not cost-effective when compared with StepUp, although the economic analyses indicated substantial uncertainty. Treatment costs were only approximately 3·6-6·8% of participants' total support costs. No treatment-related or trial-related adverse events were reported. This study is, to our knowledge, the first large randomised controlled trial assessing individual psychological interventions for people with intellectual disabilities and mental health problems. These findings show that there is no evidence that BeatIt is more effective than StepUp; both are active and potentially effective interventions. National Institute for Health Research. Copyright © 2017 Elsevier Ltd. All rights reserved.
Yin, T C; Kuwada, S
1983-10-01
We used the binaural beat stimulus to study the interaural phase sensitivity of inferior colliculus (IC) neurons in the cat. The binaural beat, produced by delivering tones of slightly different frequencies to the two ears, generates continuous and graded changes in interaural phase. Over 90% of the cells that exhibit a sensitivity to changes in the interaural delay also show a sensitivity to interaural phase disparities with the binaural beat. Cells respond with a burst of impulses with each complete cycle of the beat frequency. The period histogram obtained by binning the poststimulus time histogram on the beat frequency gives a measure of the interaural phase sensitivity of the cell. In general, there is good correspondence in the shapes of the period histograms generated from binaural beats and the interaural phase curves derived from interaural delays and in the mean interaural phase angle calculated from them. The magnitude of the beat frequency determines the rate of change of interaural phase and the sign determines the direction of phase change. While most cells respond in a phase-locked manner up to beat frequencies of 10 Hz, there are some cells tht will phase lock up to 80 Hz. Beat frequency and mean interaural phase angle are linearly related for most cells. Most cells respond equally in the two directions of phase change and with different rates of change, at least up to 10 Hz. However, some IC cells exhibit marked sensitivity to the speed of phase change, either responding more vigorously at low beat frequencies or at high beat frequencies. In addition, other cells demonstrate a clear directional sensitivity. The cells that show sensitivity to the direction and speed of phase changes would be expected to demonstrate a sensitivity to moving sound sources in the free field. Changes in the mean interaural phase of the binaural beat period histograms are used to determine the effects of changes in average and interaural intensity on the phase sensitivity of the cells. The effects of both forms of intensity variation are continuously distributed. The binaural beat offers a number of advantages for studying the interaural phase sensitivity of binaural cells. The dynamic characteristics of the interaural phase can be varied so that the speed and direction of phase change are under direct control. The data can be obtained in a much more efficient manner, as the binaural beat is about 10 times faster in terms of data collection than the interaural delay.
Xiong, Li; Tian, Ge; Wang, Li; Lin, Wenhua; Chen, Xiangyan; Leung, Thomas Wai Hong; Soo, Yannie Oi Yan; Wong, Lawrence Ka Sing
2017-07-01
External counterpulsation (ECP) is a noninvasive method used to augment cerebral perfusion in ischemic stroke. However, the response of beat-to-beat heart rate variability (HRV) in patients with ischemic stroke during ECP remains unknown. Forty-eight patients with unilateral ischemic stroke at the subacute stage and 14 healthy controls were recruited. Beat-to-beat heart rate before, during, and after ECP was monitored. The frequency components of HRV were calculated using power spectral analysis. Very low frequency (VLF; <.04 Hz), low frequency (LF; .04-.15 Hz), high frequency (HF; .15-.40 Hz), total power spectral density (TP; <.40 Hz), and LF/HF ratio were calculated. In stroke patients, although there were no statistical differences in all of the HRV components, the HRV at VLF showed a trend of increase during ECP compared with baseline in the left-sided stroke patients (P = .083). After ECP, the HRV at LF and TP remained higher than baseline in the right-sided stroke patients (LF, 209.4 versus 117.9, P = .050; TP, 1275.6 versus 390.2, P = .017, respectively). Besides, the HRV at TP also increased after ECP compared with baseline in the left-sided stroke patients (563.0 versus 298.3, P = .029). Irrespective of the side of the ischemia, patients showed an increased beat-to-beat HRV after ECP. Additionally, sympathetic and parasympathetic cardiac modulations were increased after ECP in patients after right-sided subacute stroke. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Model for the respiratory modulation of the heart beat-to-beat time interval series
NASA Astrophysics Data System (ADS)
Capurro, Alberto; Diambra, Luis; Malta, C. P.
2005-09-01
In this study we present a model for the respiratory modulation of the heart beat-to-beat interval series. The model consists of a set of differential equations used to simulate the membrane potential of a single rabbit sinoatrial node cell, excited with a periodic input signal with added correlated noise. This signal, which simulates the input from the autonomous nervous system to the sinoatrial node, was included in the pacemaker equations as a modulation of the iNaK current pump and the potassium current iK. We focus at modeling the heart beat-to-beat time interval series from normal subjects during meditation of the Kundalini Yoga and Chi techniques. The analysis of the experimental data indicates that while the embedding of pre-meditation and control cases have a roughly circular shape, it acquires a polygonal shape during meditation, triangular for the Kundalini Yoga data and quadrangular in the case of Chi data. The model was used to assess the waveshape of the respiratory signals needed to reproduce the trajectory of the experimental data in the phase space. The embedding of the Chi data could be reproduced using a periodic signal obtained by smoothing a square wave. In the case of Kundalini Yoga data, the embedding was reproduced with a periodic signal obtained by smoothing a triangular wave having a rising branch of longer duration than the decreasing branch. Our study provides an estimation of the respiratory signal using only the heart beat-to-beat time interval series.
Giving speech a hand: gesture modulates activity in auditory cortex during speech perception.
Hubbard, Amy L; Wilson, Stephen M; Callan, Daniel E; Dapretto, Mirella
2009-03-01
Viewing hand gestures during face-to-face communication affects speech perception and comprehension. Despite the visible role played by gesture in social interactions, relatively little is known about how the brain integrates hand gestures with co-occurring speech. Here we used functional magnetic resonance imaging (fMRI) and an ecologically valid paradigm to investigate how beat gesture-a fundamental type of hand gesture that marks speech prosody-might impact speech perception at the neural level. Subjects underwent fMRI while listening to spontaneously-produced speech accompanied by beat gesture, nonsense hand movement, or a still body; as additional control conditions, subjects also viewed beat gesture, nonsense hand movement, or a still body all presented without speech. Validating behavioral evidence that gesture affects speech perception, bilateral nonprimary auditory cortex showed greater activity when speech was accompanied by beat gesture than when speech was presented alone. Further, the left superior temporal gyrus/sulcus showed stronger activity when speech was accompanied by beat gesture than when speech was accompanied by nonsense hand movement. Finally, the right planum temporale was identified as a putative multisensory integration site for beat gesture and speech (i.e., here activity in response to speech accompanied by beat gesture was greater than the summed responses to speech alone and beat gesture alone), indicating that this area may be pivotally involved in synthesizing the rhythmic aspects of both speech and gesture. Taken together, these findings suggest a common neural substrate for processing speech and gesture, likely reflecting their joint communicative role in social interactions.
Giving Speech a Hand: Gesture Modulates Activity in Auditory Cortex During Speech Perception
Hubbard, Amy L.; Wilson, Stephen M.; Callan, Daniel E.; Dapretto, Mirella
2008-01-01
Viewing hand gestures during face-to-face communication affects speech perception and comprehension. Despite the visible role played by gesture in social interactions, relatively little is known about how the brain integrates hand gestures with co-occurring speech. Here we used functional magnetic resonance imaging (fMRI) and an ecologically valid paradigm to investigate how beat gesture – a fundamental type of hand gesture that marks speech prosody – might impact speech perception at the neural level. Subjects underwent fMRI while listening to spontaneously-produced speech accompanied by beat gesture, nonsense hand movement, or a still body; as additional control conditions, subjects also viewed beat gesture, nonsense hand movement, or a still body all presented without speech. Validating behavioral evidence that gesture affects speech perception, bilateral nonprimary auditory cortex showed greater activity when speech was accompanied by beat gesture than when speech was presented alone. Further, the left superior temporal gyrus/sulcus showed stronger activity when speech was accompanied by beat gesture than when speech was accompanied by nonsense hand movement. Finally, the right planum temporale was identified as a putative multisensory integration site for beat gesture and speech (i.e., here activity in response to speech accompanied by beat gesture was greater than the summed responses to speech alone and beat gesture alone), indicating that this area may be pivotally involved in synthesizing the rhythmic aspects of both speech and gesture. Taken together, these findings suggest a common neural substrate for processing speech and gesture, likely reflecting their joint communicative role in social interactions. PMID:18412134
Heterodyne laser instantaneous frequency measurement system
Wyeth, Richard W.; Johnson, Michael A.; Globig, Michael A.
1989-01-01
A heterodyne laser instantaneous frequency measurement system is disclosed. The system utilizes heterodyning of a pulsed laser beam with a continuous wave laser beam to form a beat signal. The beat signal is processed by a controller or computer which determines both the average frequency of the laser pulse and any changes or chirp of th frequency during the pulse.
Rhythmic motor entrainment in children with speech and language impairments: tapping to the beat.
Corriveau, Kathleen H; Goswami, Usha
2009-01-01
In prior work (Corriveau et al., 2007), we showed that children with speech and language impairments (SLI) were significantly less sensitive than controls to two auditory cues to rhythmic timing, amplitude envelope rise time and duration. Here we explore whether rhythmic problems extend to rhythmic motor entrainment. Tapping in synchrony with a beat has been described as the simplest rhythmic act that humans perform. We explored whether tapping to a beat would be impaired in children for whom auditory rhythmic timing is impaired. Children with SLI were indeed found to be impaired in a range of measures of paced rhythmic tapping, but were not equally impaired in tapping in an unpaced control condition requiring an internally-generated rhythm. The severity of impairment in paced tapping was linked to language and literacy outcomes.
NASA Astrophysics Data System (ADS)
Paik, Seoyoung; Lee, Sang-Yun; McCamey, Dane R.; Boehme, Christoph
2011-12-01
Electrically detected spin-Rabi beat oscillation of pairs of paramagnetic near interface states at the phosphorous doped (1016 cm-3) Si(111)/SiO2 interface is reported. Due to the g-factor anisotropy of the Pb center (a silicon surface dangling bond), one can tune intrapair Larmor frequency differences (Larmor separations) by orientation of the crystal with regard to an external magnetic field. Since Larmor separation governs the number of beating spin pairs, crystal orientation can control the beat current. This is used to identify spin states that are paired by mutual electronic transitions. The experiments confirm the presence of the previously reported 31P-Pb transition and provide direct experimental evidence of the previously hypothesized Pb-E' center (a near interface SiO2 bulk state) transition.
Control design based on dead-zone and leakage adaptive laws for artificial swarm mechanical systems
NASA Astrophysics Data System (ADS)
Zhao, Xiaomin; Chen, Y. H.; Zhao, Han
2017-05-01
We consider the control design of artificial swarm systems with emphasis on four characteristics. First, the agent is made of mechanical components. As a result, the motion of each agent is subject to physical laws that govern mechanical systems. Second, both nonlinearity and uncertainty of the mechanical system are taken into consideration. Third, the ideal agent kinematic performance is treated as a desired d'Alembert constraint. This in turn suggests a creative way of embedding the constraint into the control design. Fourth, two types of adaptive robust control schemes are designed. They both contain leakage and dead-zone. However, one design suggests a trade-off between the amount of leakage and the size of dead-zone, in exchange for a simplified dead-zone structure.
Cigarroa, Claire L; van den Bosch, Sarah J; Tang, Xiaoqi; Gauvreau, Kimberlee; Baird, Christopher W; DiNardo, James A; Kheir, John Nagi
2018-01-01
Increased alveolar dead space fraction has been associated with prolonged mechanical ventilation and increased mortality in pediatric patients with respiratory failure. The association of alveolar dead space fraction with clinical outcomes in patients undergoing bidirectional cavopulmonary anastomosis for single ventricle congenital heart disease has not been reported. We describe an association of alveolar dead space fraction with postoperative outcomes in patients undergoing bidirectional cavopulmonary anastomosis. In a retrospective case-control study, we examined for associations between alveolar dead space fraction ([PaCO2 - end-tidal CO2]/PaCO2), arterial oxyhemoglobin saturation, and transpulmonary gradient upon postoperative ICU admission with a composite primary outcome (requirement for surgical or catheter-based intervention, death, or transplant prior to hospital discharge, defining cases) and several secondary endpoints in infants following bidirectional cavopulmonary anastomosis. Cardiac ICU in a tertiary care pediatric hospital. Patients undergoing bidirectional cavopulmonary anastomosis at our institution between 2011 and 2016. None. Of 191 patients undergoing bidirectional cavopulmonary anastomosis, 28 patients were cases and 163 were controls. Alveolar dead space fraction was significantly higher in the case (0.26 ± 0.09) versus control group (0.17 ± 0.09; p < 0.001); alveolar dead space fraction at admission was less than 0.12 in 0% of cases and was greater than 0.28 in 35% of cases. Admission arterial oxyhemoglobin saturation was significantly lower in the case (77% ± 12%) versus control group (83% ± 9%; p < 0.05). Sensitivity and specificity for future case versus control assignment was best when prebidirectional cavopulmonary anastomosis risk factors, admission alveolar dead space fraction (AUC, 0.74), and arterial oxyhemoglobin saturation (AUC, 0.65) were combined in a summarial model (AUC, 0.83). For a given arterial oxyhemoglobin saturation, the odds of becoming a case increased on average by 181% for every 0.1 unit increase in alveolar dead space fraction. Admission alveolar dead space fraction and arterial oxyhemoglobin saturation were linearly associated with prolonged ICU length of stay, hospital length of stay, duration of mechanical ventilation, and duration of thoracic drainage (p < 0.001 for all). Following bidirectional cavopulmonary anastomosis, alveolar dead space fraction in excess of 0.28 or arterial oxyhemoglobin saturation less than 78% upon ICU admission indicates an increased likelihood of requiring intervention prior to hospital discharge. Increasing alveolar dead space fraction and decreasing arterial oxyhemoglobin saturation are associated with increased lengths of stay.
Characteristics in the beat-to-beat laser-Doppler waveform indices in subjects with diabetes.
Hsiu, Hsin; Hu, Hsiao-Feng; Wu, Guan-Shian; Hsiao, Fone-Ching
2014-01-01
The present study performed laser-Doppler flowmetry (LDF) measurements on the skin surface around the ankle with the aim of verifying if beat-to-beat analysis of the LDF waveform can help to discriminate the microcirculatory-blood-flow (MBF) characteristics between diabetic, prediabetic, and healthy subjects. 84 subjects were assigned to three groups (diabetic, prediabetic, and normal) according to the results of oral glucose tolerance tests. Beat-to-beat analysis was performed on the pulsatile LDF waveform to obtain foot delay time (FDT), flow rise time (FRT), and the corresponding MBF-variability parameters (FDTCV and FRTCV). Relative to the control group, FDT and FRT were significantly shorter in prediabetic subjects, FDT was significantly shorter in diabetic subjects, and FRTCV and FDTCV were significantly larger in prediabetic and diabetic subjects. There were no significant associations for FRT after adjustment for age and gender. The present results indicate that FRT may help to discriminate differences in the elastic properties of local vascular beds during diabetes or even during prediabetic stages. The proposed blood-filling-volume model can help to explain the underlying mechanism. The present findings may aid the noninvasive early detection of diabetes-associated vascular damage, and could be used in the development of home-care and telemedicine applications.
NASA Technical Reports Server (NTRS)
Cui, J.; Wilson, T. E.; Shibasaki, M.; Hodges, N. A.; Crandall, C. G.
2001-01-01
To identify whether muscle metaboreceptor stimulation alters baroreflex control of muscle sympathetic nerve activity (MSNA), MSNA, beat-by-beat arterial blood pressure (Finapres), and electrocardiogram were recorded in 11 healthy subjects in the supine position. Subjects performed 2 min of isometric handgrip exercise at 40% of maximal voluntary contraction followed by 2.5 min of posthandgrip muscle ischemia. During muscle ischemia, blood pressure was lowered and then raised by intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure was more negative (P < 0.001) during posthandgrip muscle ischemia (-201.9 +/- 20.4 units. beat(-1). mmHg(-1)) when compared with control conditions (-142.7 +/- 17.3 units. beat(-1). mmHg(-1)). No significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. However, both curves shifted during postexercise ischemia to accommodate the elevation in blood pressure and MSNA that occurs with this condition. These data suggest that the sensitivity of baroreflex modulation of MSNA is elevated by muscle metaboreceptor stimulation, whereas the sensitivity of baroreflex of modulate heart rate is unchanged during posthandgrip muscle ischemia.
Semi-automatic, octave-spanning optical frequency counter.
Liu, Tze-An; Shu, Ren-Huei; Peng, Jin-Long
2008-07-07
This work presents and demonstrates a semi-automatic optical frequency counter with octave-spanning counting capability using two fiber laser combs operated at different repetition rates. Monochromators are utilized to provide an approximate frequency of the laser under measurement to determine the mode number difference between the two laser combs. The exact mode number of the beating comb line is obtained from the mode number difference and the measured beat frequencies. The entire measurement process, except the frequency stabilization of the laser combs and the optimization of the beat signal-to-noise ratio, is controlled by a computer running a semi-automatic optical frequency counter.
NASA Astrophysics Data System (ADS)
Eclancher, Bernard; Chambron, Jacques; Dumitresco, Barbu; Karman, Miklos; Pszota, Agnes; Simon, Atilla; Didon-Poncelet, Anna; Demangeat, Jean
2002-04-01
The quantification of rapid hemodynamic reactions to wide and slow breathing movements has been performed, by two modalities (gamma) -left ventriculography of 99mTc-labeled blood volume, in anterior oblique incidence on standing and even exercising healthy volunteers and cardiac patients. A highly sensitive stethoscope delivered whole (gamma) -counts acquired at 30 msec intervals in a square field of view including the left ventricle, in a one dimensional low resolution imaging mode for beat to beat analysis. A planar 2D (gamma) -camera imaging of the same cardiac area was then performed without cardiac gating for alternate acquisitions during deep inspiration and deep expiration, completed by a 3D MRI assessment of the stethoscope detection field. Young healthy volunteers displayed wide variations of diastolic times and stroke volumes, as a result of enhanced baroreflex control, together with +/- 16% variations of the stethoscope's background blood volume counts. Any of the components of these responses were shifted, abolished or even inverted as a result of either obesity, hypertension, aging or cardiac pathologies. The assessment of breathing control of the cardiovascular system by the beat to beat (gamma) -ventriculography combined with nuclear 2D and 3D MRI imaging is a kinetic method allowing the detection of functional anomalies in still ambulatory patients.
Binaural beat technology in humans: a pilot study to assess psychologic and physiologic effects.
Wahbeh, Helané; Calabrese, Carlo; Zwickey, Heather
2007-01-01
Binaural beat technology (BBT) products are sold internationally as personal development and health improvement tools. Producers suggest benefit from regular listening to binaural beats including reduced stress and anxiety, and increased focus, concentration, motivation, confidence, and depth in meditation. Binaural beats are auditory brainstem responses that originate in the superior olivary nucleus as a result of different frequency auditory stimuli provided to each ear. Listeners to binaural beat "hear" a beat at a frequency equal to the difference between the frequencies of the applied tones. The objectives of this pilot study were to gather preliminary data on psychologic and physiologic effects of 60 days daily use of BBT for hypothesis generation and to assess compliance, feasibility, and safety for future studies. Uncontrolled pilot study. Eight healthy adults participated in the study. Participants listened to a CD with delta (0-4 Hz) binaural beat frequencies daily for 60 days. Psychologic and physiological data were collected before and after a 60-day intervention. PSYCHOLOGIC: Depression (Beck Depression Inventory-2), anxiety (State-Trait Anxiety Inventory), mood (Profile of Mood States), absorption (Tellegen Absorption Scale) and quality of Life (World Health Organization-Quality of Life Inventory). PHYSIOLOGICAL: Cortisol, dehydroepiandrosterone, melatonin, insulin-like growth factor-1, serotonin, dopamine, epinephrine, norepinephrine, weight, blood pressure, high sensitivity C-reactive protein. There was a decrease in trait anxiety (p = 0.004), an increase in quality of life (p = 0.03), and a decrease in insulin-like growth factor-1 (p = 0.01) and dopamine (p = 0.02) observed between pre- and postintervention measurements. Binaural beat technology may exhibit positive effect on self-reported psychologic measures, especially anxiety. Further research is warranted to explore the effects on anxiety using a larger, randomized and controlled trial.
A Structural Basis for How Motile Cilia Beat
Satir, Peter; Heuser, Thomas; Sale, Winfield S.
2014-01-01
The motile cilium is a mechanical wonder, a cellular nanomachine that produces a high-speed beat based on a cycle of bends that move along an axoneme made of 9+2 microtubules. The molecular motors, dyneins, power the ciliary beat. The dyneins are compacted into inner and outer dynein arms, whose activity is highly regulated to produce microtubule sliding and axonemal bending. The switch point hypothesis was developed long ago to account for how sliding in the presence of axonemal radial spoke–central pair interactions causes the ciliary beat. Since then, a new genetic, biochemical, and structural complexity has been discovered, in part, with Chlamydomonas mutants, with high-speed, high-resolution analysis of movement and with cryoelectron tomography. We stand poised on the brink of new discoveries relating to the molecular control of motility that extend and refine our understanding of the basic events underlying the switching of arm activity and of bend formation and propagation. PMID:26955066
The Effects of Meperidine Analgesia during Labor on Fetal Heart Rate
Sekhavat, Leila; Behdad, Shecoofah
2009-01-01
To estimate the effects of intramuscular meperidine analgesia on fetal heart rate (FHR) patterns compared with placebo. In a prospective randomized study, 150 healthy women with singleton term pregnancy requesting analgesia during active labor were planned to receive either intramuscular meperidin 50 mg (meperidin group) or normal saline (control group) when they requested analgesia. Fetal heart rate patterns occurring within 40 minutes of initiation of labor analgesia were retrospectively read by maternal fetal medicine specialist who was blind to type of labor analgesia. Meperidine, compared with placebo, was associated with statistically significantly less beat to beat variability (absent or less than 5 beats per minute) (28% versus 5% of fetuses, P<0.05), lower proportion of accelerations (37.3% versus 17.3% P<0.05) and of the FHR. Also FHR deceleration was significantly more than control group (25.5% versus 4%, P<0.05). Meperidine has deleterious effects on FHR. PMID:23675116
Liu, Yan-Jun; Tong, Shaocheng
2015-03-01
In the paper, an adaptive tracking control design is studied for a class of nonlinear discrete-time systems with dead-zone input. The considered systems are of the nonaffine pure-feedback form and the dead-zone input appears nonlinearly in the systems. The contributions of the paper are that: 1) it is for the first time to investigate the control problem for this class of discrete-time systems with dead-zone; 2) there are major difficulties for stabilizing such systems and in order to overcome the difficulties, the systems are transformed into an n-step-ahead predictor but nonaffine function is still existent; and 3) an adaptive compensative term is constructed to compensate for the parameters of the dead-zone. The neural networks are used to approximate the unknown functions in the transformed systems. Based on the Lyapunov theory, it is proven that all the signals in the closed-loop system are semi-globally uniformly ultimately bounded and the tracking error converges to a small neighborhood of zero. Two simulation examples are provided to verify the effectiveness of the control approach in the paper.
Bao, Ying; Wang, Dejun; Du, Zhenlan; Liu, Shuhen
2014-07-01
To determine the predicative significance of HRV and HRT to premature beat on patients with coal-worker's pneumoconiosis. 100 coal-worker's pneumoconiosis patients with premature beat (including 44 cases of occasional ventricular premature contraction and 56 cases of frequent ventricular premature contraction) were chosen as CWP group, and 50 healthy coal workers were chosen as control group. 24 h DCG was used to monitor and analyze the change of premature beat and to calculate HRV. Index: SDNN, SDANN, HFLF, HRT: TO, TS, compare HRV of CWP group and control group and the changes of HRT of both occasional and frequent ventricular premature contraction. The incidence of CWP at night (66.1%, 37 cases) is higher than that during daytime (33.9%, 19 cases), and the difference is statistically significant with P < 0.05. HRV (SDNN SDANN HF HL) indexes of CWP group are lower than control group, and the difference is statistically significant with P < 0.05. HRV indexes of control group at night are higher than that during daytime, and the difference is statistically significant with P < 0.05. Comparison of CWP group HRV indexes between day and night is statistically insignificant with P > 0.05. Compared with control group, TO of CWP group is higher while TS is lower, and the difference is statistically significant with P < 0.05. Compared with occasional ventricular premature contraction patients in CWP group, TO of frequent ventricular premature contraction patients is higher while TS is lower, and the difference is statistically significant with P < 0.05. Frequent ventricular premature contraction group in CWP group suffer from severe impaired autonomic nervous function injury, and abnormal HRV and HRT can be prognostic indicator of frequent ventricular premature contraction among coal-worker's pneumoconiosis patients.
Kario, Kazuomi
There are notable differences between Asians and Westerners regarding hypertension (HTN) and the relationship between HTN and cardiovascular disease (CVD). Asians show greater morning surges in blood pressure (BP) and a steeper slope illustrating the link between higher BP and the risk of CVD events. It is thus particularly important for Asian hypertensives to achieve 24-h BP control, including morning and night-time control. There are three components of 'perfect 24-h BP control:' the 24-h BP level, nocturnal BP dipping, and BP variability (BPV), such as the morning BP surge that can be assessed by ambulatory BP monitoring. The morning BP-guided approach using home BP monitoring (HBPM) is the first step toward perfect 24-h BP control, followed by the control of nocturnal HTN. We have been developing new HBPM devices that can measure nocturnal BP. BPV includes different time-phase variability from the shortest beat-by-beat, positional, diurnal, day-by-day, visit-to-visit, seasonal, and yearly changes. The synergistic resonance of each type of BPV would produce a great dynamic BP surge (resonance hypothesis), which triggers a CVD event, especially in the high-risk patients with systemic hemodynamic atherothrombotic syndrome (SHATS). In the future, the innovative management of HTN based on the simultaneous assessment of the resonance of all of the BPV phenotypes using a beat by beat wearable 'surge' BP monitoring device (WSP) and an information and communication technology (ICT)-based data analysis system will produce a paradigm shift from 'dots' BP management to 'seamless' ultimate individualized 'anticipation medication' for reaching a zero CVD event rate. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.
Acute control of pulmonary regurgitation with a balloon "valve". An experimental investigation.
Siwek, L G; Applebaum, R E; Jones, M; Clark, R E
1985-09-01
Operations for certain congenital cardiac lesions can produce pulmonary regurgitation. Pulmonary regurgitation contributes to right ventricular dysfunction, which may cause early postoperative morbidity and mortality. To ameliorate the problems of pulmonary regurgitation during the early postoperative period, we evaluated a method for its acute control. Complete pulmonary valvectomy was performed utilizing inflow occlusion in eight sheep. A catheter with a 15 ml spherical balloon was positioned in the pulmonary arterial trunk; its inflation and deflation were regulated by an intra-aortic balloon pump unit. Blood flow from the pulmonary arterial trunk and forward and regurgitant fraction were determined from electromagnetic flow transducer recordings. The regurgitant fraction with uncontrolled pulmonary regurgitation was 38% +/- 3% (forward flow = 42 +/- 5 ml/beat and regurgitant flow = 16 +/- 2 ml/beat). Inflation of the balloon during diastole was timed to completely eliminate pulmonary regurgitation. This balloon control of pulmonary regurgitation increased pulmonary arterial diastolic pressure from 12 +/- 1 to 17 +/- 1 mm Hg (p less than 0.0001) and decreased pulmonary arterial systolic pressure from 31 +/- 3 to 27 +/- 1 mm Hg (p = 0.06). Pulmonary arterial pulse pressure decreased from 19 +/- 3 to 9 +/- 1 mm Hg (p less than 0.003). Elimination of pulmonary regurgitation decreased right ventricular stroke volume (25 +/- 3 versus 42 +/- 5 ml/beat, p less than 0.0002) and resulted in a 46% reduction in right ventricular stroke work (5.0 +/- 0.6 versus 9.4 +/- 1.0 gm-m/beat, p less than 0.001) with no change in net forward pulmonary artery flow. Thus, acute pulmonary regurgitation can be controlled and this control improves overall hemodynamic status and decreases right ventricular work.
Beating the macroscopic quantum tunneling limit by man-made magnetic dead layers
NASA Astrophysics Data System (ADS)
Ma, Ji; Chen, Kezheng
2018-05-01
Magnetic dead layers (MDLs) are always undesirable in practical applications due to their highly frustrated spin configurations and severe degradation of host magnetism. Here we provide new insights in MDLs and unravel their attractive prospect for ferrimagnetic hybrid of Fe3O4 and γ-Fe2O3 (denoted as Fe3O4@γ-Fe2O3 in the main text) to exhibit macroscopic quantum tunneling (MQT) phenomena in measureable kelvin range. The 3 nm-sized negatively-charged Fe3O4@γ-Fe2O3 nanoparticles were immersed in various metal chloride solutions containing Mn2+, Co2+, Ni2+, Fe3+, and Fe2+ cations to form cationic MDLs via electrostatic attraction. These man-made MDLs, if being of positive enough zeta potentials, greatly disordered the magnetic dipole interactions among Fe3O4@γ-Fe2O3 nanoparticles and induce extra energy barrier to yield pronounced MQT effect in Fe3O4@γ-Fe2O3 nanoparticles even though they were dispersed neither in water nor in oil. Their crossover temperatures dividing MQT and purely thermal relaxation were found to be one order of magnitude higher than reported values in other MQT systems, and more strikingly, they could be tailored by altering the soak period in our facile and scalable route.
Brain death and true patient care
2016-01-01
The “brain death” standard as a criterion of death is closely associated with the need for transplantable organs from heart-beating donors. Are all of these potential donors really dead, or does the documented evidence of patients destined for organ harvesting who improve, or even recover to live normal lives, call into question the premise underlying “brain death”? The aim of this paper is to re-examine the notion of “brain death,” especially its clinical test-criteria, in light of a broad framework, including medical knowledge in the field of neuro-intensive care and the traditional ethics of the medical profession. I will argue that both the empirical medical evidence and the ethics of the doctor–patient relationship point to an alternative approach toward the severely comatose patient (potential brain-dead donor). Lay Summary: Though legally accepted and widely practiced, the “brain death” standard for the determination of death has remained a controversial issue, especially in view of the occurrence of “chronic brain death” survivors. This paper critically re-evaluates the clinical test-criteria for “brain death,” taking into account what is known about the neuro-critical care of severe brain injury. The medical evidence, together with the understanding of the moral role of the physician toward the patient present before him or her, indicate that an alternative approach should be offered to the deeply comatose patient. PMID:27833207
Critchley, Hugo D.; Nicotra, Alessia; Chiesa, Patrizia A.; Nagai, Yoko; Gray, Marcus A.; Minati, Ludovico; Bernardi, Luciano
2015-01-01
Controlled slow breathing (at 6/min, a rate frequently adopted during yoga practice) can benefit cardiovascular function, including responses to hypoxia. We tested the neural substrates of cardiorespiratory control in humans during volitional controlled breathing and hypoxic challenge using functional magnetic resonance imaging (fMRI). Twenty healthy volunteers were scanned during paced (slow and normal rate) breathing and during spontaneous breathing of normoxic and hypoxic (13% inspired O2) air. Cardiovascular and respiratory measures were acquired concurrently, including beat-to-beat blood pressure from a subset of participants (N = 7). Slow breathing was associated with increased tidal ventilatory volume. Induced hypoxia raised heart rate and suppressed heart rate variability. Within the brain, slow breathing activated dorsal pons, periaqueductal grey matter, cerebellum, hypothalamus, thalamus and lateral and anterior insular cortices. Blocks of hypoxia activated mid pons, bilateral amygdalae, anterior insular and occipitotemporal cortices. Interaction between slow breathing and hypoxia was expressed in ventral striatal and frontal polar activity. Across conditions, within brainstem, dorsal medullary and pontine activity correlated with tidal volume and inversely with heart rate. Activity in rostroventral medulla correlated with beat-to-beat blood pressure and heart rate variability. Widespread insula and striatal activity tracked decreases in heart rate, while subregions of insular cortex correlated with momentary increases in tidal volume. Our findings define slow breathing effects on central and cardiovascular responses to hypoxic challenge. They highlight the recruitment of discrete brainstem nuclei to cardiorespiratory control, and the engagement of corticostriatal circuitry in support of physiological responses that accompany breathing regulation during hypoxic challenge. PMID:25973923
Intercepting beats in predesignated target zones.
Craig, Cathy; Pepping, Gert-Jan; Grealy, Madeleine
2005-09-01
Moving to a rhythm necessitates precise timing between the movement of the chosen limb and the timing imposed by the beats. However, the temporal information specifying the moment when a beat will sound (the moment onto which one must synchronise one's movement) is not continuously provided by the acoustic array. Because of this informational void, the actors need some form of prospective information that will allow them to act sufficiently ahead of time in order to get their hand in the right place at the right time. In this acoustic interception study, where participants were asked to move between two targets in such a way that they arrived and stopped in the target zone at the same time as a beat sounded, we tested a model derived from tau-coupling theory (Lee DN (1998) Ecol Psychol 10:221-250). This model attempts to explain the form of a potential timing guide that specifies the duration of the inter-beat intervals and also describes how this informational guide can be used in the timing and guidance of movements. The results of our first experiment show that, for inter-beat intervals of less than 3 s, a large proportion of the movement (over 70%) can be explained by the proposed model. However, a second experiment, which augments the time between beats so that it surpasses 3 s, shows a marked decline in the percentage of information/movement coupling. A close analysis of the movement kinematics indicates a lack of control and anticipation in the participants' movements. The implications of these findings, in light of other research studies, are discussed.
Terahertz generation by beating two Langmuir waves in a warm and collisional plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xiao-Bo; Qiao, Xin; Cheng, Li-Hong
2015-09-15
Terahertz (THz) radiation generated by beating of two Langmuir waves in a warm and collisional plasma is discussed theoretically. The critical angle between the two Langmuir waves and the critical wave-length (wave vector) of Langmuir waves for generating THz radiation are obtained analytically. Furthermore, the maximum radiation energy is obtained. We find that the critical angle, the critical wave-length, and the generated radiation energy strongly depend on plasma temperature and wave-length of the Langmuir waves. That is, the THz radiation generated by beating of two Langmuir waves in a warm and collisional plasma can be controlled by adjusting the plasmamore » temperature and the Langmuir wave-length.« less
Magrì, Damiano; Piccirillo, Gianfranco; Quaglione, Raffaele; Dell'armi, Annalaura; Mitra, Marilena; Velitti, Stefania; Di Barba, Daniele; Lizio, Andrea; Maisto, Damiana; Barillà, Francesco
2012-01-01
Emotionally charged events are associated with an increased risk of sudden cardiac death (SCD). In this study we assessed RR and QT variability index (QTVI) at baseline during anger recall test (AR). We calculated QTVI from a 5-min ECG recording and from a 10-beats segment around the presumed maximum sympathetic activation in thirty post-myocardial infarction patients under β-blocker therapy and 10 controls underwent. In all groups, the low-frequency component of RR and SBP increased during AR. In all recordings, the QTVI calculated on a 5-min ECG recording and the QTVI(10 beats) were higher in patients than in controls (P < 0.05). The QTVI during AR remained unchanged from baseline within each group. Conversely, during AR, the QTVI(10 beats) in controls diminished significantly (P < 0.05) from baseline whereas in patients remained unchanged. The inability to buffer an acute stress-induced increase in sympathetic activity could explain why events charged with acute stress are associated with an increased risk of ventricular arrhythmias in this setting of patients and support the role of cognitive behavior stress management strategies.
Flagellar coordination in Chlamydomonas cells held on micropipettes.
Rüffer, U; Nultsch, W
1998-01-01
The two flagella of Chlamydomonas are known to beat synchronously: During breaststroke beating they are generally coordinated in a bilateral way while in shock responses during undulatory beating coordination is mostly parallel [Rüffer and Nultsch, 1995: Botanica Acta 108:169-276]. Analysis of a great number of shock responses revealed that in undulatory beats also periods of bilateral coordination are found and that the coordination type may change several times during a shock response, without concomitant changes of the beat envelope and the beat period. In normal wt cells no coordination changes are found during breaststroke beating, but only short temporary asynchronies: During 2 or 3 normal beats of the cis flagellum, the trans flagellum performs 3 or 4 flat beats with a reduced beat envelope and a smaller beat period, resulting in one additional trans beat. Long periods with flat beats of the same shape and beat period are found in both flagella of the non-phototactic mutant ptx1 and in defective wt 622E cells. During these periods, the coordination is parallel, the two flagella beat alternately. A correlation between normal asynchronous trans beats and the parallel-coordinated beats in the presumably cis defective cells and also the undulatory beats is discussed. In the cis defective cells, a perpetual spontaneous change between parallel beats with small beat periods (higher beat frequency) and bilateral beats with greater beat periods (lower beat frequency) are observed and render questionable the existence of two different intrinsic beat frequencies of the two flagella cis and trans. Asynchronies occur spontaneously but may also be induced by light changes, either step-up or step-down, but not by both stimuli in turn as breaststroke flagellar photoresponses (BFPRs). Asynchronies are not involved in phototaxis. They are independent of the BFPRs, which are supposed to be the basis of phototaxis. Both types of coordination must be assumed to be regulated internally, involving calcium-sensitive basal-body associated fibrous structures.
Kannan, Rajaretinam Rajesh; Vincent, Samuel Gnana Prakash
2012-03-01
The aim of the present study was to screen cardioactive herbs from Western Ghats of India. The heart beat rate (HBR) and blood flow during systole and diastole were tested in zebrafish embryos. We found that Cynodon dactylon (C. dactylon) induced increases in the HBR in zebrafish embryos with a HBR of (3.968±0.344) beats/s, which was significantly higher than that caused by betamethosone [(3.770±0.344) beats/s]. The EC50 value of C. dactylon was 3.738 µg/mL. The methanolic extract of Sida acuta (S. acuta) led to decreases in the HBR in zebrafish embryos [(1.877±0.079) beats/s], which was greater than that caused by nebivolol (positive control). The EC50 value of Sida acuta was 1.195 µg/mL. The untreated embryos had a HBR of (2.685±0.160) beats/s at 3 d post fertilization (dpf). The velocities of blood flow during the cardiac cycle were (2,291.667±72.169) µm/s for the control, (4,250±125.000) µm/s for C. dactylon and (1,083.333±72.169) µm/s for S. acuta. The LC50 values were 32.6 µg/mL for C. dactylon and 20.9 µg/mL for S. acuta. In addition, the extracts exhibited no chemical genetic effects in the drug dosage range tested. In conclusion, we developed an assay that can measure changes in cardiac function in response to herbal small molecules and determine the cardiogenic effects by microvideography.
Specific contributions of basal ganglia and cerebellum to the neural tracking of rhythm.
Nozaradan, Sylvie; Schwartze, Michael; Obermeier, Christian; Kotz, Sonja A
2017-10-01
How specific brain networks track rhythmic sensory input over time remains a challenge in neuroimaging work. Here we show that subcortical areas, namely the basal ganglia and the cerebellum, specifically contribute to the neural tracking of rhythm. We tested patients with focal lesions in either of these areas and healthy controls by means of electroencephalography (EEG) while they listened to rhythmic sequences known to induce selective neural tracking at a frequency corresponding to the most-often perceived pulse-like beat. Both patients and controls displayed neural responses to the rhythmic sequences. However, these response patterns were different across groups, with patients showing reduced tracking at beat frequency, especially for the more challenging rhythms. In the cerebellar patients, this effect was specific to the rhythm played at a fast tempo, which places high demands on the temporally precise encoding of events. In contrast, basal ganglia patients showed more heterogeneous responses at beat frequency specifically for the most complex rhythm, which requires more internal generation of the beat. These findings provide electrophysiological evidence that these subcortical structures selectively shape the neural representation of rhythm. Moreover, they suggest that the processing of rhythmic auditory input relies on an extended cortico-subcortico-cortical functional network providing specific timing and entrainment sensitivities. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dynamic regulation of heart rate during acute hypotension: new insight into baroreflex function
NASA Technical Reports Server (NTRS)
Zhang, R.; Behbehani, K.; Crandall, C. G.; Zuckerman, J. H.; Levine, B. D.; Blomqvist, C. G. (Principal Investigator)
2001-01-01
To examine the dynamic properties of baroreflex function, we measured beat-to-beat changes in arterial blood pressure (ABP) and heart rate (HR) during acute hypotension induced by thigh cuff deflation in 10 healthy subjects under supine resting conditions and during progressive lower body negative pressure (LBNP). The quantitative, temporal relationship between ABP and HR was fitted by a second-order autoregressive (AR) model. The frequency response was evaluated by transfer function analysis. Results: HR changes during acute hypotension appear to be controlled by an ABP error signal between baseline and induced hypotension. The quantitative relationship between changes in ABP and HR is characterized by a second-order AR model with a pure time delay of 0.75 s containing low-pass filter properties. During LBNP, the change in HR/change in ABP during induced hypotension significantly decreased, as did the numerator coefficients of the AR model and transfer function gain. Conclusions: 1) Beat-to-beat HR responses to dynamic changes in ABP may be controlled by an error signal rather than directional changes in pressure, suggesting a "set point" mechanism in short-term ABP control. 2) The quantitative relationship between dynamic changes in ABP and HR can be described by a second-order AR model with a pure time delay. 3) The ability of the baroreflex to evoke a HR response to transient changes in pressure was reduced during LBNP, which was due primarily to a reduction of the static gain of the baroreflex.
Effectiveness of binaural beats in reducing preoperative dental anxiety.
Isik, B K; Esen, A; Büyükerkmen, B; Kilinç, A; Menziletoglu, D
2017-07-01
Binaural beats are an auditory illusion perceived when two different pure-tone sine waves are presented one to each ear at a steady intensity and frequency. We evaluated their effectiveness in reducing preoperative anxiety in dentistry. Sixty patients (30 in each group) who were to have impacted third molars removed were studied (experimental group: 20 women and 10 men, mean (range) age 24 (18-35) years, and control group: 22 women and 8 men, mean (range) age 28 (15-47) years). All patients were fully informed about the operation preoperatively, and their anxiety recorded on a visual analogue scale (VAS). The local anaesthetic was given and the patients waited for 10minutes, during which those in the experimental group were asked to listen to binaural beats through stereo earphones (200Hz for the left ear and 209.3Hz for the right ear). No special treatment was given to the control group. In both groups anxiety was then recorded again, and the tooth removed in the usual way. The paired t test and t test were used to assess the significance of differences between groups. The degree of anxiety in the control group was unchanged after the second measurement (p=0.625), while that in the experimental group showed a significant reduction in anxiety (p=0.001). We conclude that binaural beats may be useful in reducing preoperative anxiety in dentistry. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
``Smart'' baroreception along the aortic arch, with reference to essential hypertension
NASA Astrophysics Data System (ADS)
Kember, G. C.; Zamir, M.; Armour, J. A.
2004-11-01
Beat-to-beat regulation of heart rate is dependent upon sensing of local stretching or local “disortion” by aortic baroreceptors. Distortions of the aortic wall are due mainly to left ventricular output and to reflected waves arising from the arterial tree. Distortions are generally believed to be useful in cardiac control since stretch receptors or aortic baroreceptors embedded in the adventitia of the aortic wall, transduce the distortions to cardiovascular neural reflex pathways responsible for beat-to-beat regulation of heart rate. Aortic neuroanatomy studies have also found a continuous strip of mechanosensory neurites spread along the aortic inner arch. Although their purpose is now unknown, such a combined sensing capacity would allow measurement of the space and time dependence of inner arch wall distortions due, among other things, to traveling waves associated with pulsatile flow in an elastic tube. We call this sensing capability-“smart baroreception.” In this paper we use an arterial tree model to show that the cumulative effects of wave reflections, from many sites far downstream, have a surprisingly pronounced effect on the pressure distribution in the root segment of the tree. By this mechanism global hemodynamics can be focused by wave reflections back to the aortic arch, where they can rapidly impact cardiac control via smart baroreception. Such sensing is likely important to maintain efficient heart function. However, alterations in the arterial tree due to aging and other natural processes can lead in such a system to altered cardiac control and essential hypertension.
Wanted dead or alive: scavenging versus predation by three insect predators
USDA-ARS?s Scientific Manuscript database
Many generalist insect predators may engage in facultative scavenging. If an apparent predator frequently consumes dead prey instead of live prey then the biological control services provided by that predator may be overestimated. The use of unique protein markers on live and dead prey of the same s...
What makes a rhythm complex? The influence of musical training and accent type on beat perception
Burgoyne, J. Ashley; Odijk, Daan; Honing, Henkjan; Grahn, Jessica A.
2018-01-01
Perception of a regular beat in music is inferred from different types of accents. For example, increases in loudness cause intensity accents, and the grouping of time intervals in a rhythm creates temporal accents. Accents are expected to occur on the beat: when accents are “missing” on the beat, the beat is more difficult to find. However, it is unclear whether accents occurring off the beat alter beat perception similarly to missing accents on the beat. Moreover, no one has examined whether intensity accents influence beat perception more or less strongly than temporal accents, nor how musical expertise affects sensitivity to each type of accent. In two experiments, we obtained ratings of difficulty in finding the beat in rhythms with either temporal or intensity accents, and which varied in the number of accents on the beat as well as the number of accents off the beat. In both experiments, the occurrence of accents on the beat facilitated beat detection more in musical experts than in musical novices. In addition, the number of accents on the beat affected beat finding more in rhythms with temporal accents than in rhythms with intensity accents. The effect of accents off the beat was much weaker than the effect of accents on the beat and appeared to depend on musical expertise, as well as on the number of accents on the beat: when many accents on the beat are missing, beat perception is quite difficult, and adding accents off the beat may not reduce beat perception further. Overall, the different types of accents were processed qualitatively differently, depending on musical expertise. Therefore, these findings indicate the importance of designing ecologically valid stimuli when testing beat perception in musical novices, who may need different types of accent information than musical experts to be able to find a beat. Furthermore, our findings stress the importance of carefully designing rhythms for social and clinical applications of beat perception, as not all listeners treat all rhythms alike. PMID:29320533
What makes a rhythm complex? The influence of musical training and accent type on beat perception.
Bouwer, Fleur L; Burgoyne, J Ashley; Odijk, Daan; Honing, Henkjan; Grahn, Jessica A
2018-01-01
Perception of a regular beat in music is inferred from different types of accents. For example, increases in loudness cause intensity accents, and the grouping of time intervals in a rhythm creates temporal accents. Accents are expected to occur on the beat: when accents are "missing" on the beat, the beat is more difficult to find. However, it is unclear whether accents occurring off the beat alter beat perception similarly to missing accents on the beat. Moreover, no one has examined whether intensity accents influence beat perception more or less strongly than temporal accents, nor how musical expertise affects sensitivity to each type of accent. In two experiments, we obtained ratings of difficulty in finding the beat in rhythms with either temporal or intensity accents, and which varied in the number of accents on the beat as well as the number of accents off the beat. In both experiments, the occurrence of accents on the beat facilitated beat detection more in musical experts than in musical novices. In addition, the number of accents on the beat affected beat finding more in rhythms with temporal accents than in rhythms with intensity accents. The effect of accents off the beat was much weaker than the effect of accents on the beat and appeared to depend on musical expertise, as well as on the number of accents on the beat: when many accents on the beat are missing, beat perception is quite difficult, and adding accents off the beat may not reduce beat perception further. Overall, the different types of accents were processed qualitatively differently, depending on musical expertise. Therefore, these findings indicate the importance of designing ecologically valid stimuli when testing beat perception in musical novices, who may need different types of accent information than musical experts to be able to find a beat. Furthermore, our findings stress the importance of carefully designing rhythms for social and clinical applications of beat perception, as not all listeners treat all rhythms alike.
van Wijnen, V K; Finucane, C; Harms, M P M; Nolan, H; Freeman, R L; Westerhof, B E; Kenny, R A; Ter Maaten, J C; Wieling, W
2017-12-01
Over the past 30 years, noninvasive beat-to-beat blood pressure (BP) monitoring has provided great insight into cardiovascular autonomic regulation during standing. Although traditional sphygmomanometric measurement of BP may be sufficient for detection of sustained orthostatic hypotension, it fails to capture the complexity of the underlying dynamic BP and heart rate responses. With the emerging use of noninvasive beat-to-beat BP monitoring for the assessment of orthostatic BP control in clinical and population studies, various definitions for abnormal orthostatic BP patterns have been used. Here, age-related changes in cardiovascular control in healthy subjects will be reviewed to define the spectrum of the most important abnormal orthostatic BP patterns within the first 180 s of standing. Abnormal orthostatic BP responses can be defined as initial orthostatic hypotension (a transient systolic BP fall of >40 mmHg within 15 s of standing), delayed BP recovery (an inability of systolic BP to recover to a value of >20 mmHg below baseline at 30 s after standing) and sustained orthostatic hypotension (a sustained decline in systolic BP of ≥20 mmHg occurring 60-180 s after standing). In the evaluation of patients with light-headedness, pre(syncope), (unexplained) falls or suspected autonomic dysfunction, it is essential to distinguish between normal cardiovascular autonomic regulation and these abnormal orthostatic BP responses. The prevalence, clinical relevance and underlying pathophysiological mechanisms of these patterns differ significantly across the lifespan. Initial orthostatic hypotension is important for identifying causes of syncope in younger adults, whereas delayed BP recovery and sustained orthostatic hypotension are essential for evaluating the risk of falls in older adults. © 2017 The Authors Journal of Internal Medicine published by John Wiley & Sons Ltd on behalf of Association for Publication of The Journal of Internal Medicine.
Farkas, Attila S; Makra, Péter; Csík, Norbert; Orosz, Szabolcs; Shattock, Michael J; Fülöp, Ferenc; Forster, Tamás; Csanády, Miklós; Papp, Julius Gy; Varró, András; Farkas, András
2009-01-01
Background and purpose: The Na+/Ca2+ exchanger (NCX) may contribute to triggered activity and transmural dispersion of repolarization, which are substrates of torsades de pointes (TdP) type arrhythmias. This study examined the effects of selective inhibition of the NCX by SEA0400 on the occurrence of dofetilide-induced TdP. Experimental approach: Effects of SEA0400 (1 µmol·L−1) on dofetilide-induced TdP was studied in isolated, Langendorff-perfused, atrioventricular (AV)-blocked rabbit hearts. To verify the relevance of the model, lidocaine (30 µmol·L−1) and verapamil (750 nmol·L−1) were also tested against dofetilide-induced TdP. Key results: Acute AV block caused a chaotic idioventricular rhythm and strikingly increased beat-to-beat variability of the RR and QT intervals. SEA0400 exaggerated the dofetilide-induced increase in the heart rate-corrected QT interval (QTc) and did not reduce the incidence of dofetilide-induced TdP [100% in the SEA0400 + dofetilide group vs. 75% in the dofetilide (100 nmol·L−1) control]. In the second set of experiments, verapamil further increased the dofetilide-induced QTc prolongation and neither verapamil nor lidocaine reduced the dofetilide-induced increase in the beat-to-beat variability of the QT interval. However, lidocaine decreased and verapamil prevented the development of dofetilide-induced TdP as compared with the dofetilide control (TdP incidence: 13%, 0% and 88% respectively). Conclusions and implications: Na+/Ca2+ exchanger does not contribute to dofetilide-induced TdP, whereas Na+ and Ca2+ channel activity is involved in TdP genesis in isolated, AV-blocked rabbit hearts. Neither QTc prolongation nor an increase in the beat-to-beat variability of the QT interval is a sufficient prerequisite of TdP genesis in rabbit hearts. PMID:19222480
Wang, Lijie; Li, Hongyi; Zhou, Qi; Lu, Renquan
2017-09-01
This paper investigates the problem of observer-based adaptive fuzzy control for a category of nonstrict feedback systems subject to both unmodeled dynamics and fuzzy dead zone. Through constructing a fuzzy state observer and introducing a center of gravity method, unmeasurable states are estimated and the fuzzy dead zone is defuzzified, respectively. By employing fuzzy logic systems to identify the unknown functions. And combining small-gain approach with adaptive backstepping control technique, a novel adaptive fuzzy output feedback control strategy is developed, which ensures that all signals involved are semi-globally uniformly bounded. Simulation results are given to demonstrate the effectiveness of the presented method.
Does respiratory sinus arrhythmia occur in fishes?
Campbell, Hamish A; Taylor, Edwin W; Egginton, Stuart
2005-01-01
The hypothesis that respiratory modulation of heart rate variability (HRV) or respiratory sinus arrhythmia (RSA) is restricted to mammals was tested on four Antarctic and four sub-Antarctic species of fish, that shared close genotypic or ecotypic similarities but, due to their different environmental temperatures, faced vastly different selection pressures related to oxygen supply. The intrinsic heart rate (fH) for all the fish species studied was ∼25% greater than respiration rate (fV), but vagal activity successively delayed heart beats, producing a resting fH that was synchronized with fV in a progressive manner. Power spectral statistics showed that these episodes of relative bradycardia occurred in a cyclical manner every 2–4 heart beats in temperate species but at >4 heart beats in Antarctic species, indicating a more relaxed selection pressure for cardio-respiratory coupling. This evidence that vagally mediated control of fH operates around the ventilatory cycle in fish demonstrates that influences similar to those controlling RSA in mammals operate in non-mammalian vertebrates. PMID:17148239
Paramecium swimming and ciliary beating patterns: a study on four RNA interference mutations.
Funfak, Anette; Fisch, Cathy; Abdel Motaal, Hatem T; Diener, Julien; Combettes, Laurent; Baroud, Charles N; Dupuis-Williams, Pascale
2015-01-01
Paramecium cells swim and feed by beating their thousands of cilia in coordinated patterns. The organization of these patterns and its relationship with cell motility has been the subject of a large body of work, particularly as a model for ciliary beating in human organs where similar organization is seen. However the rapid motion of the cells makes quantitative measurements very challenging. Here we provide detailed measurements of the swimming of Paramecium cells from high-speed video at high magnification, as they move in microfluidic channels. An image analysis protocol allows us to decouple the cell movement from the motion of the cilia, thus allowing us to measure the ciliary beat frequency (CBF) and the spatio-temporal organization into metachronal waves along the cell periphery. Two distinct values of the CBF appear at different regions of the cell: most of the cilia beat in the range of 15 to 45 Hz, while the cilia in the peristomal region beat at almost double the frequency. The body and peristomal CBF display a nearly linear relation with the swimming velocity. Moreover the measurements do not display a measurable correlation between the swimming velocity and the metachronal wave velocity on the cell periphery. These measurements are repeated for four RNAi silenced mutants, where proteins specific to the cilia or to their connection to the cell base are depleted. We find that the mutants whose ciliary structure is affected display similar swimming to the control cells albeit with a reduced efficiency, while the mutations that affect the cilia's anchoring to the cell lead to strongly reduced ability to swim. This reduction in motility can be related to a loss of coordination between the ciliary beating in different parts of the cell.
Pregnancy outcome of threatened abortion with demonstrable fetal cardiac activity: a cohort study.
Tongsong, T; Srisomboon, J; Wanapirak, C; Sirichotiyakul, S; Pongsatha, S; Polsrisuthikul, T
1995-08-01
Pregnancy with visible fetal heart beat complicated by first trimester threatened abortion had significant increased risk of subsequent spontaneous abortion compared with normal pregnancy. To compare pregnancy outcomes in cases complicated by first trimester threatened abortion with those that were not. Prospective cohort study of 255 cases of first trimester threatened abortions but with visible heart beat and 265 other normal pregnancies. Spontaneous abortion rates of 5.5% (with relative abortal risk of 2.91) was found for study group, compared to 1.88% for controls (p < 0.05). Preterm delivery was also higher, but was not statistically significant. First trimester bleeding with visible fetal heart beat appears to associate significantly with higher subsequent spontaneous abortion rate than those without.
Tonelli, Adriano R; Wang, Xiao-Feng; Alkukhun, Laith; Zhang, Qi; Dweik, Raed A; Minai, Omar A
2014-06-01
Six-minute walk test (6MWT) continues to be a useful tool to determine the functional capacity in patients with vascular and other lung diseases; nevertheless, it has a limited ability to predict prognosis in this context. We tested whether the heart rate (HR) acceleration and decay slopes during the 6-m walk test are different in patients with pulmonary arterial hypertension (PAH), other lung diseases, and healthy controls. In addition, we assessed whether the HR slopes are associated with clinical worsening. Using a portable, signal-morphology-based, impedance cardiograph (PhysioFlow Enduro, Paris, France) with real-time wireless monitoring via a Bluetooth USB adapter we determined beat-by-beat HR. We included 50 subjects in this pilot study, 20 with PAH (all on PAH-specific treatment), 17 with other lung diseases (obstructive [n = 12, 71%] or restrictive lung diseases [5, 29%]), and 13 healthy controls. The beat-by-beat HR curves were significantly different among all three groups of subjects either during the activity or recovery of the 6MWT. HR curves were less steep in PAH than the other two groups (P < 0.001). HR acceleration rates were slower in patients with PAH or other lung diseases with progression of their disease (P < 0.001). In conclusion, the acceleration and decay slopes during 6MWT are different among patients with PAH, other lung diseases, and healthy controls. The HR slopes during 6MWT were steeper in patients without clinical worsening. © 2014 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Nul, D R; Doval, H C; Grancelli, H O; Varini, S D; Soifer, S; Perrone, S V; Prieto, N; Scapin, O
1997-05-01
The impact of amiodarone on mortality in patients with severe congestive heart failure (CHF) (New York Heart Association functional classes II [advanced], III and IV; left ventricular ejection fraction < 35%) In the Grupo de Estudio de la Sobrevida en la Insuficiencia Cardiaca en Argentina (GESICA) trial was analyzed in relation to initial mean baseline heart rate (BHR) and its change after 6 months of follow-up. Trials of amiodarone therapy in CHF have produced discordant results, suggesting that the effect is not uniform in all patient subgroups with regard to survival. The present analysis was carried out in 516 patients randomized to receive amiodarone, 300 mg/day (n = 260), or nonantiarrhythmic therapy (n = 256, control group) and followed up for 2 years. Survival was evaluated for patients with a BHR > or = 90 beats/min (control: n = 132; amiodarone: n = 122) and < 90 beats/min (control: n = 124; amiodarone: n = 138). Survival was also analyzed according to heart rate reduction at 6 months for 367 patients. For patients with a BHR > or = 90 beats/min, amiodarone therapy reduced mortality to 38.4% compared with 62.4% in control patients (relative risk [RR] 0.55, 95% confidence interval [CI] 0.35 to 0.95, p < 0.002). Both sudden death (RR 0.46, 95% CI 0.24 to 0.90, p < 0.02) and progressive heart failure death (RR 0.60, 95% CI 0.30 to 1.03, p < 0.06) were reduced, and functional capacity was improved. In patients with a BHR < 90 beats/min, amiodarone did not alter survival. Among 367 patients who completed 6 months of follow-up, amiodarone reduced 2-year mortality only in those with a BHR > or = 90 beats/min, which was reduced at 6 months. Elevated rest heart rates in severe CHF identify a subgroup of patients who benefit from treatment with amiodarone. Amiodarone-induced heart rate slowing may be an important benefit for patients.
A comparison of auditory evoked potentials to acoustic beats and to binaural beats.
Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi
2010-04-01
The purpose of this study was to compare cortical brain responses evoked by amplitude modulated acoustic beats of 3 and 6 Hz in tones of 250 and 1000 Hz with those evoked by their binaural beats counterparts in unmodulated tones to indicate whether the cortical processes involved differ. Event-related potentials (ERPs) were recorded to 3- and 6-Hz acoustic and binaural beats in 2000 ms duration 250 and 1000 Hz tones presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to beats-evoked oscillations were determined and compared across beat types, beat frequencies and base (carrier) frequencies. All stimuli evoked tone-onset components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude in response to acoustic than to binaural beats, to 250 than to 1000 Hz base frequency and to 3 Hz than to 6 Hz beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left temporal lobe areas. Differences between estimated sources of potentials to acoustic and binaural beats were not significant. The perceptions of binaural beats involve cortical activity that is not different than acoustic beats in distribution and in the effects of beat- and base frequency, indicating similar cortical processing. Copyright 2010 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Petrick, E. J.
1973-01-01
An analytical study was made of the stability of a closed-loop liquid-lithium temperature control of the primary loop of a conceptual nuclear Brayton space powerplant. The operating point was varied from 20 to 120 percent of design. A describing-function technique was used to evaluate the effects of temperature dead band and control coupling backlash. From the system investigation, it was predicted that a limit cycle will not exist with a temperature dead band, but a limit cycle will not exist when backlash is present. The results compare favorably with a digital computer simulation.
Adaptive Fault-Tolerant Control of Uncertain Nonlinear Large-Scale Systems With Unknown Dead Zone.
Chen, Mou; Tao, Gang
2016-08-01
In this paper, an adaptive neural fault-tolerant control scheme is proposed and analyzed for a class of uncertain nonlinear large-scale systems with unknown dead zone and external disturbances. To tackle the unknown nonlinear interaction functions in the large-scale system, the radial basis function neural network (RBFNN) is employed to approximate them. To further handle the unknown approximation errors and the effects of the unknown dead zone and external disturbances, integrated as the compounded disturbances, the corresponding disturbance observers are developed for their estimations. Based on the outputs of the RBFNN and the disturbance observer, the adaptive neural fault-tolerant control scheme is designed for uncertain nonlinear large-scale systems by using a decentralized backstepping technique. The closed-loop stability of the adaptive control system is rigorously proved via Lyapunov analysis and the satisfactory tracking performance is achieved under the integrated effects of unknown dead zone, actuator fault, and unknown external disturbances. Simulation results of a mass-spring-damper system are given to illustrate the effectiveness of the proposed adaptive neural fault-tolerant control scheme for uncertain nonlinear large-scale systems.
Dead space and slope indices from the expiratory carbon dioxide tension-volume curve.
Kars, A H; Bogaard, J M; Stijnen, T; de Vries, J; Verbraak, A F; Hilvering, C
1997-08-01
The slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate (PIE), were investigated in 28 healthy control subjects, 12 asthma and 29 emphysema patients (20 severely obstructed and nine moderately obstructed) with the aim to establish diagnostic value. Because breath volume and frequency are closely related to CO2 elimination, the recording procedures included varying breath volumes in all subjects during self-chosen/natural breathing frequency, and fixed frequencies of 10, 15 and 20 breaths x min(-1) with varying breath volumes only in the healthy controls. From the relationships of the variables with tidal volume (VT), the values at 1 L were estimated to compare the groups. The slopes of phase 3 and VD,Bohr at 1 L VT showed the most significant difference between controls and patients with asthma or emphysema, compared to the other two dead space estimates, and were related to the degree of airways obstruction. Discrimination between no-emphysema (asthma and controls) and emphysema patients was possible on the basis of a plot of intercept and slope of the relationship between VD,Bohr and VT. A combination of both the slope of phase 3 and VD,Bohr of a breath of 1 L was equally discriminating. The influence of fixed frequencies in the controls did not change the results. The conclusion is that Bohr dead space in relation to tidal volume seems to have diagnostic properties separating patients with asthma from patients with emphysema with the same degree of airways obstruction. Equally discriminating was a combination of both phase 3 and Bohr dead space of a breath of 1 L. The different pathophysiological mechanisms in asthma and emphysema leading to airways obstruction are probably responsible for these results.
The brain responses to different frequencies of binaural beat sounds on QEEG at cortical level.
Jirakittayakorn, Nantawachara; Wongsawat, Yodchanan
2015-01-01
Beat phenomenon is occurred when two slightly different frequency waves interfere each other. The beat can also occur in the brain by providing two slightly different frequency waves separately each ear. This is called binaural beat. The brain responses to binaural beat are in discussion process whether the brain side and the brain area. Therefore, this study aims to figure out the brain responses to binaural beat by providing different binaural beat frequencies on 250 carrier tone continuously for 30 minutes to participants and using quantitative electroencephalography (QEEG) to interpret the data. The result shows that different responses appear in different beat frequency. Left hemisphere dominance occur in 3 Hz beat within 15 minutes and 15 Hz beat within 5 minutes. Right hemisphere dominance occurs in 10 Hz beat within 25 minute. 6 Hz beat enhances all area of the brain within 10 minutes. 8 Hz and 25 Hz beats have no clearly responses while 40 Hz beat enhances the responses in frontal lobe. These brain responses can be used for brain modulation application to induce the brain activity in further studies.
Porta, Alberto; Bari, Vlasta; Bassani, Tito; Marchi, Andrea; Tassin, Stefano; Canesi, Margherita; Barbic, Franca; Furlan, Raffaello
2013-01-01
Entropy-based approaches are frequently used to quantify complexity of short-term cardiovascular control from spontaneous beat-to-beat variability of heart period (HP) and systolic arterial pressure (SAP). Among these tools the ones optimizing a critical parameter such as the pattern length are receiving more and more attention. This study compares two entropy-based techniques for the quantification of complexity making use of completely different strategies to optimize the pattern length. Comparison was carried out over HP and SAP variability series recorded from 12 Parkinson's disease (PD) patients without orthostatic hypotension or symptoms of orthostatic intolerance and 12 age-matched healthy control (HC) subjects. Regardless of the method, complexity of cardiovascular control increased in PD group, thus suggesting the early impairment of cardiovascular function.
Pasquier, Jennifer; Gupta, Renuka; Rioult, Damien; Hoarau-Véchot, Jessica; Courjaret, Raphael; Machaca, Khaled; Al Suwaidi, Jassim; Stanley, Edouard G; Rafii, Shahin; Elliott, David A; Abi Khalil, Charbel; Rafii, Arash
2017-06-01
Pluripotent human embryonic stem cells (hESC) are a promising source of repopulating cardiomyocytes. We hypothesized that we could improve maturation of cardiomyocytes and facilitate electrical interconnections by creating a model that more closely resembles heart tissue; that is, containing both endothelial cells (ECs) and cardiomyocytes. We induced cardiomyocyte differentiation in the coculture of an hESC line expressing the cardiac reporter NKX2.5-green fluorescent protein (GFP), and an Akt-activated EC line (E4 + ECs). We quantified spontaneous beating rates, synchrony, and coordination between different cardiomyocyte clusters using confocal imaging of Fura Red-detected calcium transients and computer-assisted image analysis. After 8 days in culture, 94% ± 6% of the NKX2-5GFP + cells were beating when hESCs embryonic bodies were plated on E4 + ECs compared with 34% ± 12.9% for controls consisting of hESCs cultured on BD Matrigel (BD Biosciences) without ECs at Day 11 in culture. The spatial organization of beating areas in cocultures was different. The GFP + cardiomyocytes were close to the E4 + ECs. The average beats/min of the cardiomyocytes in coculture was faster and closer to physiologic heart rates compared with controls (50 ± 14 [n = 13] vs 25 ± 9 [n = 8]; p < 0.05). The coculture with ECs led to synchronized beating relying on the endothelial network, as illustrated by the loss of synchronization upon the disruption of endothelial bridges. The coculturing of differentiating cardiomyocytes with Akt-activated ECs but not EC-conditioned media results in (1) improved efficiency of the cardiomyocyte differentiation protocol and (2) increased maturity leading to better intercellular coupling with improved chronotropy and synchrony. Copyright © 2017. Published by Elsevier Inc.
Solov'eva, K B; Dolbin, I V; Koroleva, E B
2013-01-01
The purpose was to study in-flight blood pressure (BP) and heart rate (HR) in polar transport aviation pilots afflicted with essential hypertension. A total of 30 pilots were distributed into 2 groups: hypertensive pilots and those who, though generally healthy were, because of some conditions and lifestyle, predisposed to the cardiovascular risk (CVR). The examination included establishment of personal CVR factors, electrocardiography, bicycle ergometry, echocardiography, off-duty 24-hour BP and HR monitoring, and in-flight BP and HR monitoring. Maximum BP and HR values were higher in hypertensive pilots as compared with the control group. In the first group, maximum systolic BP (sBP) on the rise measured 202 mm Hg vs. 179 mm Hg in the control group. The highest HR on the rise was also registered in the first group (164 beats/min vs. 127 beats/min in the control). At landing, maximum sBP and HR made up 253 and 163 mm Hg, 150 and 141 beats/min values in groups first and second, respectively. To summarize, in the harsh weather conditions of Far North hypertensive pilots experience particularly heavy hemodynamic stresses during flight and, consequently, must be allowed to fly only if their hypertension is under control.
Effect of Acute Mental Stress on Heart Rate and QT Variability in Postmyocardial Infarction Patients
Magrì, Damiano; Piccirillo, Gianfranco; Quaglione, Raffaele; Dell'Armi, Annalaura; Mitra, Marilena; Velitti, Stefania; Di Barba, Daniele; Lizio, Andrea; Maisto, Damiana; Barillà, Francesco
2012-01-01
Emotionally charged events are associated with an increased risk of sudden cardiac death (SCD). In this study we assessed RR and QT variability index (QTVI) at baseline during anger recall test (AR). We calculated QTVI from a 5-min ECG recording and from a 10-beats segment around the presumed maximum sympathetic activation in thirty post-myocardial infarction patients under β-blocker therapy and 10 controls underwent. In all groups, the low-frequency component of RR and SBP increased during AR. In all recordings, the QTVI calculated on a 5-min ECG recording and the QTVI10 beats were higher in patients than in controls (P < 0.05). The QTVI during AR remained unchanged from baseline within each group. Conversely, during AR, the QTVI10 beats in controls diminished significantly (P < 0.05) from baseline whereas in patients remained unchanged. The inability to buffer an acute stress-induced increase in sympathetic activity could explain why events charged with acute stress are associated with an increased risk of ventricular arrhythmias in this setting of patients and support the role of cognitive behavior stress management strategies. PMID:22844616
Howarth, F C; Jacobson, M; Naseer, O; Adeghate, E
2005-03-01
A variety of contractility defects have been reported in the streptozotocin (STZ)-induced diabetic rat heart including alterations to the amplitude and time course of cardiac muscle contraction. Transmitter devices were surgically implanted in the peritoneal cavity of young adult male Wistar rats. Electrodes from the transmitter were arranged in Einthoven bipolar lead II configuration. Electrocardiogram (ECG), physical activity and body temperature data were continuously recorded with a telemetry system before and following the administration of STZ (60 mg kg-1). Heart rate (HR), physical activity and body temperature declined rapidly 3-5 days after administration of STZ. The effects became more conspicuous with time and reached a new steady state approximately 10 days after STZ treatment when HR was 255+/-8 beats min-1 in diabetic rats compared to 348+/-17 beats min-1 in age-matched controls. Heart rate variability (HRV) was also significantly reduced after STZ treatment (18+/-3 beats min-1) compared to controls (36+/-3 beats min-1). Reduced physical activity and/or body temperature may partly underlie the reduction in HR and HRV. Reductions in power spectral density at higher frequencies (2.5-3.5 Hz) suggest that parasympathetic drive to the heart may be altered during the early stages of STZ-induced diabetes. Short-term diabetes-induced changes in vital signs can be effectively tracked by continuous recording using a telemetry system.
Red Reveals Branch Die-back in Norway Maple Acer platanoides
Sinkkonen, Aki
2008-01-01
Background and Aims Physiological data suggest that autumn leaf colours of deciduous trees are adaptations to environmental stress. Recently, the evolution of autumn colouration has been linked to tree condition and defence. Most current hypotheses presume that autumn colours vary between tree individuals. This study was designed to test if within-tree variation should be taken into account in experimental and theoretical research on autumn colouration. Methods Distribution of red autumn leaf colours was compared between partially dead and vigorous specimens of Norway maple (Acer platanoides) in a 3-year study. In August, the amount of reddish foliage was estimated in pairs of partially dead and control trees. Within-tree variation in the distribution of reddish leaves was evaluated. Leaf nitrogen and carbon concentrations were analysed. Key Results Reddish leaf colours were more frequent in partially dead trees than in control trees. Reddish leaves were evenly distributed in control trees, while patchiness of red leaf pigments was pronounced in partially dead trees. Large patches of red leaves were found beneath or next to dead tree parts. These patches reoccurred every year. Leaf nitrogen concentration was lower in reddish than in green leaves but the phenomenon seemed similar in both partially dead and control trees. Conclusions The results suggest that red leaf colouration and branch condition are interrelated in Norway maple. Early reddish colours may be used as an indication of leaf nitrogen and carbon levels but not as an indication of tree condition. Studies that concentrate on entire trees may not operate at an optimal level to detect the evolutionary mechanisms behind autumnal leaf colour variation. PMID:18567914
Red reveals branch die-back in Norway maple Acer platanoides.
Sinkkonen, Aki
2008-09-01
Physiological data suggest that autumn leaf colours of deciduous trees are adaptations to environmental stress. Recently, the evolution of autumn colouration has been linked to tree condition and defence. Most current hypotheses presume that autumn colours vary between tree individuals. This study was designed to test if within-tree variation should be taken into account in experimental and theoretical research on autumn colouration. Distribution of red autumn leaf colours was compared between partially dead and vigorous specimens of Norway maple (Acer platanoides) in a 3-year study. In August, the amount of reddish foliage was estimated in pairs of partially dead and control trees. Within-tree variation in the distribution of reddish leaves was evaluated. Leaf nitrogen and carbon concentrations were analysed. Reddish leaf colours were more frequent in partially dead trees than in control trees. Reddish leaves were evenly distributed in control trees, while patchiness of red leaf pigments was pronounced in partially dead trees. Large patches of red leaves were found beneath or next to dead tree parts. These patches reoccurred every year. Leaf nitrogen concentration was lower in reddish than in green leaves but the phenomenon seemed similar in both partially dead and control trees. The results suggest that red leaf colouration and branch condition are interrelated in Norway maple. Early reddish colours may be used as an indication of leaf nitrogen and carbon levels but not as an indication of tree condition. Studies that concentrate on entire trees may not operate at an optimal level to detect the evolutionary mechanisms behind autumnal leaf colour variation.
Lengyel, Csaba; Orosz, Andrea; Hegyi, Péter; Komka, Zsolt; Udvardy, Anna; Bosnyák, Edit; Trájer, Emese; Pavlik, Gábor; Tóth, Miklós; Wittmann, Tibor; Papp, Julius Gy.; Varró, András; Baczkó, István
2011-01-01
Background Sudden cardiac death in competitive athletes is rare but it is significantly more frequent than in the normal population. The exact cause is seldom established and is mostly attributed to ventricular fibrillation. Myocardial hypertrophy and slow heart rate, both characteristic changes in top athletes in response to physical conditioning, could be associated with increased propensity for ventricular arrhythmias. We investigated conventional ECG parameters and temporal short-term beat-to-beat variability of repolarization (STVQT), a presumptive novel parameter for arrhythmia prediction, in professional soccer players. Methods Five-minute 12-lead electrocardiograms were recorded from professional soccer players (n = 76, all males, age 22.0±0.61 years) and age-matched healthy volunteers who do not participate in competitive sports (n = 76, all males, age 22.0±0.54 years). The ECGs were digitized and evaluated off-line. The temporal instability of beat-to-beat heart rate and repolarization were characterized by the calculation of short-term variability of the RR and QT intervals. Results Heart rate was significantly lower in professional soccer players at rest (61±1.2 vs. 72±1.5/min in controls). The QT interval was prolonged in players at rest (419±3.1 vs. 390±3.6 in controls, p<0.001). QTc was significantly longer in players compared to controls calculated with Fridericia and Hodges correction formulas. Importantly, STVQT was significantly higher in players both at rest and immediately after the game compared to controls (4.8±0.14 and 4.3±0.14 vs. 3.5±0.10 ms, both p<0.001, respectively). Conclusions STVQT is significantly higher in professional soccer players compared to age-matched controls, however, further studies are needed to relate this finding to increased arrhythmia propensity in this population. PMID:21526208
Michael A. Jenkins; George R. Parker
1997-01-01
The volume and decay stages of down dead wood were evaluated across a chronosequence of 46 silvicultural openings and 10 uncut control stands to determine how down dead wood volume changes with stand development. Openings ranged in age from 8 to 26 years and were divided into three age groups: (1) 16 years. Individual logs...
Does Mckuer's Law Hold for Heart Rate Control via Biofeedback Display?
NASA Technical Reports Server (NTRS)
Courter, B. J.; Jex, H. R.
1984-01-01
Some persons can control their pulse rate with the aid of a biofeedback display. If the biofeedback display is modified to show the error between a command pulse-rate and the measured rate, a compensatory (error correcting) heart rate tracking control loop can be created. The dynamic response characteristics of this control loop when subjected to step and quasi-random disturbances were measured. The control loop includes a beat-to-beat cardiotachmeter differenced with a forcing function from a quasi-random input generator; the resulting error pulse-rate is displayed as feedback. The subject acts to null the displayed pulse-rate error, thereby closing a compensatory control loop. McRuer's Law should hold for this case. A few subjects already skilled in voluntary pulse-rate control were tested for heart-rate control response. Control-law properties are derived, such as: crossover frequency, stability margins, and closed-loop bandwidth. These are evaluated for a range of forcing functions and for step as well as random disturbances.
NASA Technical Reports Server (NTRS)
Smith, David D.
2015-01-01
Next-generation space missions are currently constrained by existing spacecraft navigation systems which are not fully autonomous. These systems suffer from accumulated dead-reckoning errors and must therefore rely on periodic corrections provided by supplementary technologies that depend on line-of-sight signals from Earth, satellites, or other celestial bodies for absolute attitude and position determination, which can be spoofed, incorrectly identified, occluded, obscured, attenuated, or insufficiently available. These dead-reckoning errors originate in the ring laser gyros themselves, which constitute inertial measurement units. Increasing the time for standalone spacecraft navigation therefore requires fundamental improvements in gyroscope technologies. One promising solution to enhance gyro sensitivity is to place an anomalous dispersion or fast light material inside the gyro cavity. The fast light essentially provides a positive feedback to the gyro response, resulting in a larger measured beat frequency for a given rotation rate as shown in figure 1. Game Changing Development has been investing in this idea through the Fast Light Optical Gyros (FLOG) project, a collaborative effort which began in FY 2013 between NASA Marshall Space Flight Center (MSFC), the U.S. Army Aviation and Missile Research, Development, and Engineering Center (AMRDEC), and Northwestern University. MSFC and AMRDEC are working on the development of a passive FLOG (PFLOG), while Northwestern is developing an active FLOG (AFLOG). The project has demonstrated new benchmarks in the state of the art for scale factor sensitivity enhancement. Recent results show cavity scale factor enhancements of approx.100 for passive cavities.
The Challenges of Diagnosing Primary Ciliary Dyskinesia
O'Callaghan, Christopher; Knowles, Michael R.
2011-01-01
Primary ciliary dyskinesia (PCD) is a rare genetic disorder of ciliary structure and function. The diagnosis can be challenging, particularly when using nongenetic assays. The “gold standard” diagnostic test is ultrastructural analysis of respiratory cilia obtained by nasal scrape or brush biopsy. A few specialized centers use high-speed videomicroscopy to examine ciliary beat. Certain beat patterns correlate with ultrastructural defects, and, in some cases, subtle alterations in beat pattern can be seen when ultrastructure is normal. Recent studies have shown that nasal nitric oxide (NO) is very low in patients with PCD compared with healthy control subjects; therefore, this assay may be a useful screening or adjunctive test for PCD. Because acute respiratory illnesses may yield alterations in ciliary ultrastructure, ciliary beat, and nasal NO values, these tests should be performed during a stable baseline period. Identification of an array of PCD genes has provided the opportunity for making a definitive genetic diagnosis for PCD in some cases. All of these approaches have a role in diagnosing PCD. For example, PCD has been confirmed by identifying disease-causing mutations in a heavy dynein chain gene in individuals with normal ciliary ultrastructure but subtle defects in ciliary beat and low nasal NO. Priorities to improve nongenetic diagnostic capability include standardization of nasal NO as a screening test and the development of specialized centers using uniform approaches for the analysis of ciliary ultrastructure and ciliary beat pattern. Another chapter in this issue (see Zariwala and colleagues, pp. 430) addresses the progress toward improved capabilities for definitive genetic testing PMID:21926395
NASA Astrophysics Data System (ADS)
De la Sen, M.; Nistal, R.; Alonso-Quesada, S.; Garrido, A. J.
2016-08-01
This paper studies the non-negativity and stability properties of the solutions of a newly proposed SEIADR model which incorporates asymptomatic and dead-infective subpopulations to those defining the standard SEIR model and, in parallel, it incorporates feedback vaccination and antiviral treatment controls.
Binaural beats increase interhemispheric alpha-band coherence between auditory cortices.
Solcà, Marco; Mottaz, Anaïs; Guggisberg, Adrian G
2016-02-01
Binaural beats (BBs) are an auditory illusion occurring when two tones of slightly different frequency are presented separately to each ear. BBs have been suggested to alter physiological and cognitive processes through synchronization of the brain hemispheres. To test this, we recorded electroencephalograms (EEG) at rest and while participants listened to BBs or a monaural control condition during which both tones were presented to both ears. We calculated for each condition the interhemispheric coherence, which expressed the synchrony between neural oscillations of both hemispheres. Compared to monaural beats and resting state, BBs enhanced interhemispheric coherence between the auditory cortices. Beat frequencies in the alpha (10 Hz) and theta (4 Hz) frequency range both increased interhemispheric coherence selectively at alpha frequencies. In a second experiment, we evaluated whether this coherence increase has a behavioral aftereffect on binaural listening. No effects were observed in a dichotic digit task performed immediately after BBs presentation. Our results suggest that BBs enhance alpha-band oscillation synchrony between the auditory cortices during auditory stimulation. This effect seems to reflect binaural integration rather than entrainment. Copyright © 2015 Elsevier B.V. All rights reserved.
Jones, Jenny; Thomson, Patricia; Lauder, William; Howie, Kate; Leslie, Stephen J
2013-08-01
This study measured the effects of reflexology in 12 reflexology-naive patients with chronic heart failure in a placebo-controlled, double blind randomised controlled study design. Outcomes included 'beat-to-beat' non-invasive continuous measurement of cardiovascular parameters and measurement of state of anxiety and pain/discomfort. There were no changes in any of the haemodynamic parameters measured (all p > 0.05). Perceived state of anxiety was significantly reduced post treatment in the control group only (p = 0.03). Reflexology applied to the feet of patients with chronic heart failure appears to have no immediate haemodynamic effects. While any long term treatment effect is uncertain, it would appear that reflexology is safe for use in this patient group. Copyright © 2013 Elsevier Ltd. All rights reserved.
Liver transplantation in Japan.
Soyama, Akihiko; Eguchi, Susumu; Egawa, Hiroto
2016-10-01
As of December 31, 2014, 7937 liver transplants (7673 living donor transplants and 264 deceased donor liver transplantations [DDLTs; 261 from heart-beating donors and 3 from non-heart-beating donors]) have been performed in 67 institutions in Japan. The revised Organ Transplant Law in Japan came into effect in July 2010, which allows organ procurement from brain-dead individuals, including children, with family consent if the patient had not previously refused organ donation. However, the number of deceased donor organ donations has not increased as anticipated. The rate of deceased organ donations per million population (pmp) has remained at less than 1. To maximize the viability of the limited numbers of donated organs, a system has been adopted that includes the partnership of well-trained transplant consultant doctors and local doctors. For compensating for the decreased opportunity of on-site training, an educational system regarding quality organ procurement for transplant surgeons has also been established. Furthermore, experts in the field of liver transplantation are currently discussing adoption of the Model for End-Stage Liver Disease score for allocation, promoting split-liver transplantation, arranging in-house coordinators, and improving the frequency of proposing the option to donate organs to the families. To overcome the shortage of donors during efforts to promote organ donation, living donor liver transplantation (LDLT) has been developed in Japan. Continuous efforts to increase DDLT in addition to the successful experience of LDLT will increase the benefits of liver transplantation for more patients. Liver Transplantation 22 1401-1407 2016 AASLD. © 2016 by the American Association for the Study of Liver Diseases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zakharyash, Valerii F; Kashirsky, Aleksandr V; Klementyev, Vasilii M
2005-09-30
Various oscillation regimes of an actively mode-locked semiconductor laser are studied experimentally. Two types of regimes are found in which the minimal spectral width ({approx}3.5 kHz) of intermode beats is achieved. The width of the optical spectrum of modes is studied as a function of their locking and the feedback coefficients. The maximum width of the spectrum is {approx}3.7 THz. (control of laser radiation parameters)
NASA Technical Reports Server (NTRS)
Starc, V.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M. A.; Delgado, R.
2007-01-01
We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.
McKenzie, D J; Campbell, H A; Taylor, E W; Micheli, M; Rantin, F T; Abe, A S
2007-12-01
The jeju is a teleost fish with bimodal respiration that utilizes a modified swim bladder as an air-breathing organ (ABO). Like all air-breathing fish studied to date, jeju exhibit pronounced changes in heart rate (fH) during air-breathing events, and it is believed that these may facilitate oxygen uptake (MO2) from the ABO. The current study employed power spectral analysis (PSA) of fH patterns, coupled with instantaneous respirometry, to investigate the autonomic control of these phenomena and their functional significance for the efficacy of air breathing. The jeju obtained less than 5% of total MO2 (MtO2) from air breathing in normoxia at 26 degrees C, and PSA of beat-to-beat variability in fH revealed a pattern similar to that of unimodal water-breathing fish. In deep aquatic hypoxia (water PO2)=1 kPa) the jeju increased the frequency of air breathing (fAB) tenfold and maintained MtO2 unchanged from normoxia. This was associated with a significant increase in heart rate variability (HRV), each air breath (AB) being preceded by a brief bradycardia and then followed by a brief tachycardia. These fH changes are qualitatively similar to those associated with breathing in unimodal air-breathing vertebrates. Within 20 heartbeats after the AB, however, a beat-to-beat variability in fH typical of water-breathing fish was re-established. Pharmacological blockade revealed that both adrenergic and cholinergic tone increased simultaneously prior to each AB, and then decreased after it. However, modulation of inhibitory cholinergic tone was responsible for the major proportion of HRV, including the precise beat-to-beat modulation of fH around each AB. Pharmacological blockade of all variations in fH associated with air breathing in deep hypoxia did not, however, have a significant effect upon fAB or the regulation of MtO2. Thus, the functional significance of the profound HRV during air breathing remains a mystery.
Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.
Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A
2001-01-01
Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A controlled trial that includes binaural beat tapes as an adjunctive treatment to conventional therapy for mild anxiety may be warranted.
Gram-Negative Bacterial Wound Infections
2014-05-01
shows an effect with increasing concentration, however survival analysis does not show a significant difference between treatment groups and controls ...with 3 dead larvae in the 25 mM group compared to a single dead larva in the control group (Fig. 7). Probit analysis estimates the lethal...statistically differ- ent from that of the control group . The levels (CFU/g) of bacteria in lung tissue correlated with the survival curves. The median
PID tuning rules for SOPDT systems: review and some new results.
Panda, Rames C; Yu, Cheng-Ching; Huang, Hsiao-Ping
2004-04-01
PID controllers are widely used in industries and so many tuning rules have been proposed over the past 50 years that users are often lost in the jungle of tuning formulas. Moreover, unlike PI control, different control laws and structures of implementation further complicate the use of the PID controller. In this work, five different tuning rules are taken for study to control second-order plus dead time systems with wide ranges of damping coefficients and dead time to time constant ratios (D/tau). Four of them are based on IMC design with different types of approximations on dead time and the other on desired closed-loop specifications (i.e., specified forward transfer function). The method of handling dead time in the IMC type of design is important especially for systems with large D/tau ratios. A systematic approach was followed to evaluate the performance of controllers. The regions of applicability of suitable tuning rules are highlighted and recommendations are also given. It turns out that IMC designed with the Maclaurin series expansion type PID is a better choice for both set point and load changes for systems with D/tau greater than 1. For systems with D/tau less than 1, the desired closed-loop specification approach is favored.
Binaural Beat: A Failure to Enhance EEG Power and Emotional Arousal
López-Caballero, Fran; Escera, Carles
2017-01-01
When two pure tones of slightly different frequencies are delivered simultaneously to the two ears, is generated a beat whose frequency corresponds to the frequency difference between them. That beat is known as acoustic beat. If these two tones are presented one to each ear, they still produce the sensation of the same beat, although no physical combination of the tones occurs outside the auditory system. This phenomenon is called binaural beat. In the present study, we explored the potential contribution of binaural beats to the enhancement of specific electroencephalographic (EEG) bands, as previous studies suggest the potential usefulness of binaural beats as a brainwave entrainment tool. Additionally, we analyzed the effects of binaural-beat stimulation on two psychophysiological measures related to emotional arousal: heart rate and skin conductance. Beats of five different frequencies (4.53 Hz -theta-, 8.97 Hz -alpha-, 17.93 Hz -beta-, 34.49 Hz -gamma- or 57.3 Hz -upper-gamma) were presented binaurally and acoustically for epochs of 3 min (Beat epochs), preceded and followed by pink noise epochs of 90 s (Baseline and Post epochs, respectively). In each of these epochs, we analyzed the EEG spectral power, as well as calculated the heart rate and skin conductance response (SCR). For all the beat frequencies used for stimulation, no significant changes between Baseline and Beat epochs were observed within the corresponding EEG bands, neither with binaural or with acoustic beats. Additional analysis of spectral EEG topographies yielded negative results for the effect of binaural beats in the scalp distribution of EEG spectral power. In the psychophysiological measures, no changes in heart rate and skin conductance were observed for any of the beat frequencies presented. Our results do not support binaural-beat stimulation as a potential tool for the enhancement of EEG oscillatory activity, nor to induce changes in emotional arousal. PMID:29187819
Binaural Beat: A Failure to Enhance EEG Power and Emotional Arousal.
López-Caballero, Fran; Escera, Carles
2017-01-01
When two pure tones of slightly different frequencies are delivered simultaneously to the two ears, is generated a beat whose frequency corresponds to the frequency difference between them. That beat is known as acoustic beat. If these two tones are presented one to each ear, they still produce the sensation of the same beat, although no physical combination of the tones occurs outside the auditory system. This phenomenon is called binaural beat. In the present study, we explored the potential contribution of binaural beats to the enhancement of specific electroencephalographic (EEG) bands, as previous studies suggest the potential usefulness of binaural beats as a brainwave entrainment tool. Additionally, we analyzed the effects of binaural-beat stimulation on two psychophysiological measures related to emotional arousal: heart rate and skin conductance. Beats of five different frequencies (4.53 Hz -theta-, 8.97 Hz -alpha-, 17.93 Hz -beta-, 34.49 Hz -gamma- or 57.3 Hz -upper-gamma) were presented binaurally and acoustically for epochs of 3 min (Beat epochs), preceded and followed by pink noise epochs of 90 s (Baseline and Post epochs, respectively). In each of these epochs, we analyzed the EEG spectral power, as well as calculated the heart rate and skin conductance response (SCR). For all the beat frequencies used for stimulation, no significant changes between Baseline and Beat epochs were observed within the corresponding EEG bands, neither with binaural or with acoustic beats. Additional analysis of spectral EEG topographies yielded negative results for the effect of binaural beats in the scalp distribution of EEG spectral power. In the psychophysiological measures, no changes in heart rate and skin conductance were observed for any of the beat frequencies presented. Our results do not support binaural-beat stimulation as a potential tool for the enhancement of EEG oscillatory activity, nor to induce changes in emotional arousal.
Satir, Peter
1963-01-01
Upon excision into spring water, the lateral cilia of the gill of the freshwater mussel Elliptio complanatus (Solander) stop beating, but 0.04 M potassium ion can activate the gill so that these cilia again beat with metachronal rhythm. One per cent osmium tetroxide quickly pipetted onto a fully activated gill fixes the lateral cilia in a pattern that preserves the form and arrangement of the metachronal wave, and permits the cilia to be studied with the electron microscope in all stages of their beat cycle. Changes are seen in the fixed active preparation that are not present in the inactive control, i.e., in the packing of the cilia, the position of the axis of the ciliary cross-section, and the diameter of the ring of peripheral filaments. Analysis of these parameters may lead to new correlations between ciliary fine structure and function. PMID:14079494
Fairfax, Seth T; Holwerda, Seth W; Credeur, Daniel P; Zuidema, Mozow Y; Medley, John H; Dyke II, Peter C; Wray, D Walter; Davis, Michael J; Fadel, Paul J
2013-01-01
Sympathetic vascular transduction is commonly understood to act as a basic relay mechanism, but under basal conditions, competing dilatory signals may interact with and alter the ability of sympathetic activity to decrease vascular conductance. Thus, we determined the extent to which spontaneous bursts of muscle sympathetic nerve activity (MSNA) mediate decreases in forearm vascular conductance (FVC) and the contribution of local α-adrenergic receptor-mediated pathways to the observed FVC responses. In 19 young men, MSNA (microneurography), arterial blood pressure and brachial artery blood flow (duplex Doppler ultrasound) were continuously measured during supine rest. These measures were also recorded in seven men during intra-arterial infusions of normal saline, phentolamine (PHEN) and PHEN with angiotensin II (PHEN+ANG). The latter was used to control for increases in resting blood flow with α-adrenergic blockade. Spike-triggered averaging was used to characterize beat-by-beat changes in FVC for 15 cardiac cycles following each MSNA burst and a peak response was calculated. Following MSNA bursts, FVC initially increased by +3.3 ± 0.3% (P= 0.016) and then robustly decreased to a nadir of −5.8 ± 1.6% (P < 0.001). The magnitude of vasoconstriction appeared graded with the number of consecutive MSNA bursts; while individual burst size only had a mild influence. Neither PHEN nor PHEN+ANG infusions affected the initial rise in FVC, but both infusions significantly attenuated the subsequent decrease in FVC (–2.1 ± 0.7% and –0.7 ± 0.8%, respectively; P < 0.001 vs. normal saline). These findings indicate that spontaneous MSNA bursts evoke robust beat-by-beat decreases in FVC that are exclusively mediated via α-adrenergic receptors. PMID:23652594
Intile, Peter J.; Balzer, Grant J.; Wolfgang, Matthew C.
2015-01-01
ABSTRACT The Pseudomonas aeruginosa type III secretion system (T3SS) is a primary virulence factor important for phagocytic avoidance, disruption of host cell signaling, and host cell cytotoxicity. ExsA is the master regulator of T3SS transcription. The expression, synthesis, and activity of ExsA is tightly regulated by both intrinsic and extrinsic factors. Intrinsic regulation consists of the well-characterized ExsECDA partner-switching cascade, while extrinsic factors include global regulators that alter exsA transcription and/or translation. To identify novel extrinsic regulators of ExsA, we conducted a transposon mutagenesis screen in the absence of intrinsic control. Transposon disruptions within gene PA2840, which encodes a homolog of the Escherichia coli RNA-helicase DeaD, significantly reduced T3SS gene expression. Recent studies indicate that E. coli DeaD can promote translation by relieving inhibitory secondary structures within target mRNAs. We report here that PA2840, renamed DeaD, stimulates ExsA synthesis at the posttranscriptional level. Genetic experiments demonstrate that the activity of an exsA translational fusion is reduced in a deaD mutant. In addition, exsA expression in trans fails to restore T3SS gene expression in a deaD mutant. We hypothesized that DeaD relaxes mRNA secondary structure to promote exsA translation and found that altering the mRNA sequence of exsA or the native exsA Shine-Dalgarno sequence relieved the requirement for DeaD in vivo. Finally, we show that purified DeaD promotes ExsA synthesis using in vitro translation assays. Together, these data reveal a novel regulatory mechanism for P. aeruginosa DeaD and add to the complexity of global regulation of T3SS. IMPORTANCE Although members of the DEAD box family of RNA helicases are appreciated for their roles in mRNA degradation and ribosome biogenesis, an additional role in gene regulation is now emerging in bacteria. By relaxing secondary structures in mRNAs, DEAD box helicases are now thought to promote translation by enhancing ribosomal recruitment. We identify here an RNA helicase that plays a critical role in promoting ExsA synthesis, the central regulator of the Pseudomonas aeruginosa type III secretion system, and provide additional evidence that DEAD box helicases directly stimulate translation of target genes. The finding that DeaD stimulates exsA translation adds to a growing list of transcriptional and posttranscriptional regulatory mechanisms that control type III gene expression. PMID:26055113
Fujii, Shinya; Schlaug, Gottfried
2013-01-01
Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session.
Fujii, Shinya; Schlaug, Gottfried
2013-01-01
Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session. PMID:24324421
Valero, R; García-Valdecasas, J C; Net, M; Beltran, J; Ordi, J; González, F X; López-Boado, M A; Almenara, R; Taurá, P; Elena, M; Capdevila, L; Manyalich, M; Visa, J
2000-09-15
To evaluate whether L-arginine reduces liver and biliary tract damage after transplantation from non heart-beating donor pigs. Twenty-five animals received an allograft from non-heart-beating donors. After 40 min of cardiac arrest, normothermic recirculation was run for 30 min. The animals were randomly treated with L-arginine (400 mg x kg(-1) during normothermic recirculation) or saline (control group). Then, the animals were cooled and their livers were transplanted after 6 hr of cold ischemia. The animals were killed on the 5th day, liver damage was assessed on wedged liver biopsies by a semiquantitative analysis and by morphometric analysis of the necrotic areas, and biliary tract damage by histological examination of the explanted liver. Seventeen animals survived the study period. The histological parameters assessed (sinusoidal congestion and dilatation, sinusoidal infiltration by polymorphonuclear cells and lymphocytes, endothelitis, dissociation of liver cell plates, and centrilobular necrosis) were significantly worse in the control group. The necrotic area affected 15.9 +/- 14.5% of the liver biopsies in the control group and 3.7 +/- 3.1% in the L-arginine group (P<0.05). Six of eight animal in the control group and only one of eight survivors in the L-arginine group developed ischemic cholangitis (P<0.01). L-Arginine administration was associated with higher portal blood flow (676.9 +/- 149.46 vs. 475.2 +/- 205.6 ml x min x m(-2); P<0.05), higher hepatic hialuronic acid extraction at normothermic recirculation (38.8 +/- 53.7% vs. -4.2 +/- 18.2%; P<0.05) and after reperfusion (28.6 +/- 55.5% vs. -10.9 +/- 15.5%; P<0.05) and lower levels of alpha-glutation-S-transferase at reperfusion (1325 +/- 1098% respect to baseline vs. 6488 +/- 5612%; P<0.02). L-Arginine administration during liver procurement from non heart beating donors prevents liver and biliary tract damage.
Li, Zhijun; Su, Chun-Yi
2013-09-01
In this paper, adaptive neural network control is investigated for single-master-multiple-slaves teleoperation in consideration of time delays and input dead-zone uncertainties for multiple mobile manipulators carrying a common object in a cooperative manner. Firstly, concise dynamics of teleoperation systems consisting of a single master robot, multiple coordinated slave robots, and the object are developed in the task space. To handle asymmetric time-varying delays in communication channels and unknown asymmetric input dead zones, the nonlinear dynamics of the teleoperation system are transformed into two subsystems through feedback linearization: local master or slave dynamics including the unknown input dead zones and delayed dynamics for the purpose of synchronization. Then, a model reference neural network control strategy based on linear matrix inequalities (LMI) and adaptive techniques is proposed. The developed control approach ensures that the defined tracking errors converge to zero whereas the coordination internal force errors remain bounded and can be made arbitrarily small. Throughout this paper, stability analysis is performed via explicit Lyapunov techniques under specific LMI conditions. The proposed adaptive neural network control scheme is robust against motion disturbances, parametric uncertainties, time-varying delays, and input dead zones, which is validated by simulation studies.
Tagging the neuronal entrainment to beat and meter.
Nozaradan, Sylvie; Peretz, Isabelle; Missal, Marcus; Mouraux, André
2011-07-13
Feeling the beat and meter is fundamental to the experience of music. However, how these periodicities are represented in the brain remains largely unknown. Here, we test whether this function emerges from the entrainment of neurons resonating to the beat and meter. We recorded the electroencephalogram while participants listened to a musical beat and imagined a binary or a ternary meter on this beat (i.e., a march or a waltz). We found that the beat elicits a sustained periodic EEG response tuned to the beat frequency. Most importantly, we found that meter imagery elicits an additional frequency tuned to the corresponding metric interpretation of this beat. These results provide compelling evidence that neural entrainment to beat and meter can be captured directly in the electroencephalogram. More generally, our results suggest that music constitutes a unique context to explore entrainment phenomena in dynamic cognitive processing at the level of neural networks.
Breska, Assaf; Deouell, Leon Y
2016-07-06
Environmental rhythms potently drive predictive resource allocation in time, typically leading to perceptual and motor benefits for on-beat, relative to off-beat, times, even if the rhythmic stream is not intentionally used. In two human EEG experiments, we investigated the behavioral and electrophysiological expressions of using rhythms to direct resources away from on-beat times. This allowed us to distinguish goal-directed attention from the automatic capture of attention by rhythms. The following three conditions were compared: (1) a rhythmic stream with targets appearing frequently at a fixed off-beat position; (2) a rhythmic stream with targets appearing frequently at on-beat times; and (3) a nonrhythmic stream with matched target intervals. Shifting resources away from on-beat times was expressed in the slowing of responses to on-beat targets, but not in the facilitation of off-beat targets. The shifting of resources was accompanied by anticipatory adjustment of the contingent negative variation (CNV) buildup toward the expected off-beat time. In the second experiment, off-beat times were jittered, resulting in a similar CNV adjustment and also in preparatory amplitude reduction of beta-band activity. Thus, the CNV and beta activity track the relevance of time points and not the rhythm, given sufficient incentive. Furthermore, the effects of task relevance (appearing in a task-relevant vs irrelevant time) and rhythm (appearing on beat vs off beat) had additive behavioral effects and also dissociable neural manifestations in target-evoked activity: rhythm affected the target response as early as the P1 component, while relevance affected only the later N2 and P3. Thus, these two factors operate by distinct mechanisms. Rhythmic streams are widespread in our environment, and are typically conceptualized as automatic, bottom-up resource attractors to on-beat times-preparatory neural activity peaks at rhythm-on-beat times and behavioral benefits are seen to on-beat compared with off-beat targets. We show that this behavioral benefit is reversed when targets are more frequent at off-beat compared with on-beat times, and that preparatory neural activity, previously thought to be driven by the rhythm to on-beat times, is adjusted toward off-beat times. Furthermore, the effect of this relevance-based shifting on target-evoked brain activity was dissociable from the automatic effect of rhythms. Thus, rhythms can act as cues for flexible resource allocation according to the goal relevance of each time point, instead of being obligatory resource attractors. Copyright © 2016 the authors 0270-6474/16/367154-13$15.00/0.
1994-09-01
of te1 e B Iti-me reater thany engine aen both operating. Sound levels on the This nestle beat flux is too times eater than Jlower half of the...torso simulator was used in nlight for the binaural recording of noise and conmmunication Moreover the use of pasive tnot*: control mteasures... beating ", of the propellers. It is then recog.point due to a source at the first [10, 11]. Hence, rather nized that the sound fields of the individual
Padmanabhan, R; Hildreth, A J; Laws, D
2005-09-01
Pre-operative anxiety is common and often significant. Ambulatory surgery challenges our pre-operative goal of an anxiety-free patient by requiring people to be 'street ready' within a brief period of time after surgery. Recently, it has been demonstrated that music can be used successfully to relieve patient anxiety before operations, and that audio embedded with tones that create binaural beats within the brain of the listener decreases subjective levels of anxiety in patients with chronic anxiety states. We measured anxiety with the State-Trait Anxiety Inventory questionnaire and compared binaural beat audio (Binaural Group) with an identical soundtrack but without these added tones (Audio Group) and with a third group who received no specific intervention (No Intervention Group). Mean [95% confidence intervals] decreases in anxiety scores were 26.3%[19-33%] in the Binaural Group (p = 0.001 vs. Audio Group, p < 0.0001 vs. No Intervention Group), 11.1%[6-16%] in the Audio Group (p = 0.15 vs. No Intervention Group) and 3.8%[0-7%] in the No Intervention Group. Binaural beat audio has the potential to decrease acute pre-operative anxiety significantly.
Zena, Lucas A; Leite, Cléo A C; Longhini, Leonardo S; Dias, Daniel P M; da Silva, Glauber S F; Hartzler, Lynn K; Gargaglioni, Luciane H; Bícego, Kênia C
2017-11-23
Beat-to-beat variation in heart rate (f H ) has been used as a tool for elucidating the balance between sympathetic and parasympathetic modulation of the heart. A portion of the temporal changes in f H is evidenced by a respiratory influence (cardiorespiratory interaction) on heart rate variability (HRV) with heartbeats increasing and decreasing within a respiratory cycle. Nevertheless, little is known about respiratory effects on HRV in lower vertebrates. By using frequency domain analysis, we provide the first evidence of a ventilatory component in HRV similar to mammalian respiratory sinus arrhythmia in an amphibian, the toad Rhinella schneideri. Increases in the heartbeats arose synchronously with each lung inflation cycle, an intermittent breathing pattern comprised of a series of successive lung inflations. A well-marked peak in the HRV signal matching lung inflation cycle was verified in toads whenever lung inflation cycles exhibit a regular rhythm. The cardiac beat-to-beat variation evoked at the moment of lung inflation accounts for both vagal and sympathetic influences. This cardiorespiratory interaction may arise from interactions between central and peripheral feedback mechanisms governing cardiorespiratory control and may underlie important cardiorespiratory adjustments for gas exchange improvement especially under extreme conditions like low oxygen availability.
Waliwitiya, Ranil; Belton, Peter; Nicholson, Russell A; Lowenberger, Carl A
2010-03-01
The effects were evaluated of the plant terpenoid thymol and eight other neuroactive compounds on flight muscle impulses (FMIs) and wing beat frequency (WBF) of tethered blowflies (Phaenicia sericata Meig.). The electrical activity of the dorsolongitudinal flight muscles was closely linked to the WBF of control insects. Topically applied thymol inhibited WBF within 15-30 min and reduced FMI frequency. Octopamine and chlordimeform caused a similar, early-onset bursting pattern that decreased in amplitude with time. Desmethylchlordimeform blocked wing beating within 60 min and generated a profile of continuous but lower-frequency FMIs. Fipronil suppressed wing beating and induced a pattern of continuous, variable-frequency spiking that diminished gradually over 6 h. Cypermethrin- and rotenone-treated flies had initial strong FMIs that declined with time. In flies injected with GABA, the FMIs were generally unidirectional and frequency was reduced, as was seen with thymol. Thymol readily penetrates the cuticle and interferes with flight muscle and central nervous function in the blowfly. The similarity of the action of thymol and GABA suggests that this terpenoid acts centrally in blowflies by mimicking or facilitating GABA action.
Multivariate and multiorgan analysis of cardiorespiratory variability signals: the CAP sleep case.
Bianchi, Anna M; Ferini-Strambi, Luigi; Castronovo, Vincenza; Cerutti, Sergio
2006-10-01
Signals from different systems are analyzed during sleep on a beat-to-beat basis to provide a quantitative measure of synchronization with the heart rate variability (HRV) signal, oscillations of which reflect the action of the autonomic nervous system. Beat-to-beat variability signals synchronized to QRS occurrence on ECG signals were extracted from respiration, electroencephalogram (EEG) and electromyogram (EMG) traces. The analysis was restricted to sleep stage 2. Cyclic alternating pattern (CAP) periods were detected from EEG signals and the following conditions were identified: stage 2 non-CAP (2 NCAP), stage 2 CAP (2 CAP) and stage 2 CAP with myoclonus (2 CAP MC). The coupling relationships between pairs of variability signals were studied in both the time and frequency domains. Passing from 2 NCAP to 2 CAP, sympathetic activation is indicated by tachycardia and reduced respiratory arrhythmia in the heart rate signal. At the same time, we observed a marked link between EEG and HRV at the CAP frequency. During 2 CAP MC, the increased synchronization involved myoclonus and respiration. The underlying mechanism seems to be related to a global control system at the central level that involves the different systems.
Hearing, feeling or seeing a beat recruits a supramodal network in the auditory dorsal stream.
Araneda, Rodrigo; Renier, Laurent; Ebner-Karestinos, Daniela; Dricot, Laurence; De Volder, Anne G
2017-06-01
Hearing a beat recruits a wide neural network that involves the auditory cortex and motor planning regions. Perceiving a beat can potentially be achieved via vision or even touch, but it is currently not clear whether a common neural network underlies beat processing. Here, we used functional magnetic resonance imaging (fMRI) to test to what extent the neural network involved in beat processing is supramodal, that is, is the same in the different sensory modalities. Brain activity changes in 27 healthy volunteers were monitored while they were attending to the same rhythmic sequences (with and without a beat) in audition, vision and the vibrotactile modality. We found a common neural network for beat detection in the three modalities that involved parts of the auditory dorsal pathway. Within this network, only the putamen and the supplementary motor area (SMA) showed specificity to the beat, while the brain activity in the putamen covariated with the beat detection speed. These results highlighted the implication of the auditory dorsal stream in beat detection, confirmed the important role played by the putamen in beat detection and indicated that the neural network for beat detection is mostly supramodal. This constitutes a new example of convergence of the same functional attributes into one centralized representation in the brain. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Performance evaluation of an improved fish robot actuated by piezoceramic actuators
NASA Astrophysics Data System (ADS)
Nguyen, Q. S.; Heo, S.; Park, H. C.; Byun, D.
2010-03-01
This paper presents an improved fish robot actuated by four lightweight piezocomposite actuators. Our newly developed actuation mechanism is simple to fabricate because it works without gears. With the new actuation mechanism, the fish robot has a 30% smaller cross section than our previous model. Performance tests of the fish robot in water were carried out to measure the tail-beat angle, the thrust force, the swimming speed for various tail-beat frequencies from 1 to 5 Hz and the turning radius at the optimal frequency. The maximum swimming speed of the fish robot is 7.7 cm s - 1 at a tail-beat frequency of 3.9 Hz. A turning experiment shows that the swimming direction of the fish robot can be controlled by changing the duty ratio of the driving voltage; the fish robot has a turning radius of 0.41 m for a left turn and 0.68 m for a right turn.
Iwakuni, Kana; Inaba, Hajime; Nakajima, Yoshiaki; Kobayashi, Takumi; Hosaka, Kazumoto; Onae, Atsushi; Hong, Feng-Lei
2012-06-18
We have developed an optical frequency comb using a mode-locked fiber ring laser with an intra-cavity waveguide electro-optic modulator controlling the optical length in the laser cavity. The mode-locking is achieved with a simple ring configuration and a nonlinear polarization rotation mechanism. The beat note between the laser and a reference laser and the carrier envelope offset frequency of the comb were simultaneously phase locked with servo bandwidths of 1.3 MHz and 900 kHz, respectively. We observed an out-of-loop beat between two identical combs, and obtained a coherent δ-function peak with a signal to noise ratio of 70 dB/Hz.
Exaggerated heart rate oscillations during two meditation techniques.
Peng, C K; Mietus, J E; Liu, Y; Khalsa, G; Douglas, P S; Benson, H; Goldberger, A L
1999-07-31
We report extremely prominent heart rate oscillations associated with slow breathing during specific traditional forms of Chinese Chi and Kundalini Yoga meditation techniques in healthy young adults. We applied both spectral analysis and a novel analytic technique based on the Hilbert transform to quantify these heart rate dynamics. The amplitude of these oscillations during meditation was significantly greater than in the pre-meditation control state and also in three non-meditation control groups: i) elite athletes during sleep, ii) healthy young adults during metronomic breathing, and iii) healthy young adults during spontaneous nocturnal breathing. This finding, along with the marked variability of the beat-to-beat heart rate dynamics during such profound meditative states, challenges the notion of meditation as only an autonomically quiescent state.
Cortical evoked potentials to an auditory illusion: binaural beats.
Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi
2009-08-01
To define brain activity corresponding to an auditory illusion of 3 and 6Hz binaural beats in 250Hz or 1000Hz base frequencies, and compare it to the sound onset response. Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000Hz to one ear and 3 or 6Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3Hz and 6Hz, in base frequencies of 250Hz and 1000Hz. Tones were 2000ms in duration and presented with approximately 1s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. All stimuli evoked tone-onset P(50), N(100) and P(200) components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P(50) had significantly different sources than the beats-evoked oscillations; and N(100) and P(200) sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp.
Cortical Evoked Potentials to an Auditory Illusion: Binaural Beats
Pratt, Hillel; Starr, Arnold; Michalewski, Henry J.; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi
2009-01-01
Objective: To define brain activity corresponding to an auditory illusion of 3 and 6 Hz binaural beats in 250 Hz or 1,000 Hz base frequencies, and compare it to the sound onset response. Methods: Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000 Hz to one ear and 3 or 6 Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3 Hz and 6 Hz, in base frequencies of 250 Hz and 1000 Hz. Tones were 2,000 ms in duration and presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. Results: All stimuli evoked tone-onset P50, N100 and P200 components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P50 had significantly different sources than the beats-evoked oscillations; and N100 and P200 sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Conclusions: Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Significance: Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp. PMID:19616993
Zuk, Nathaniel J.; Carney, Laurel H.; Lalor, Edmund C.
2018-01-01
Prior research has shown that musical beats are salient at the level of the cortex in humans. Yet below the cortex there is considerable sub-cortical processing that could influence beat perception. Some biases, such as a tempo preference and an audio frequency bias for beat timing, could result from sub-cortical processing. Here, we used models of the auditory-nerve and midbrain-level amplitude modulation filtering to simulate sub-cortical neural activity to various beat-inducing stimuli, and we used the simulated activity to determine the tempo or beat frequency of the music. First, irrespective of the stimulus being presented, the preferred tempo was around 100 beats per minute, which is within the range of tempi where tempo discrimination and tapping accuracy are optimal. Second, sub-cortical processing predicted a stronger influence of lower audio frequencies on beat perception. However, the tempo identification algorithm that was optimized for simple stimuli often failed for recordings of music. For music, the most highly synchronized model activity occurred at a multiple of the beat frequency. Using bottom-up processes alone is insufficient to produce beat-locked activity. Instead, a learned and possibly top-down mechanism that scales the synchronization frequency to derive the beat frequency greatly improves the performance of tempo identification. PMID:29896080
Webb, Alastair J S; Mazzucco, Sara; Li, Linxin; Rothwell, Peter M
2018-01-01
Visit-to-visit and day-to-day blood pressure (BP) variability (BPV) predict an increased risk of cardiovascular events but only reflect 1 form of BPV. Beat-to-beat BPV can be rapidly assessed and might also be predictive. In consecutive patients within 6 weeks of transient ischemic attack or nondisabling stroke (Oxford Vascular Study), BPV (coefficient of variation) was measured beat-to-beat for 5 minutes (Finometer), day-to-day for 1 week on home monitoring (3 readings, 3× daily), and on awake ambulatory BP monitoring. BPV after 1-month standard treatment was related (Cox proportional hazards) to recurrent stroke and cardiovascular events for 2 to 5 years, adjusted for mean systolic BP. Among 520 patients, 26 had inadequate beat-to-beat recordings, and 22 patients were in atrial fibrillation. Four hundred five patients had all forms of monitoring. Beat-to-beat BPV predicted recurrent stroke and cardiovascular events independently of mean systolic BP (hazard ratio per group SD, stroke: 1.47 [1.12-1.91]; P =0.005; cardiovascular events: 1.41 [1.08-1.83]; P =0.01), including after adjustment for age and sex (stroke: 1.47 [1.12-1.92]; P =0.005) and all risk factors (1.40 [1.00-1.94]; P =0.047). Day-to-day BPV was less strongly associated with stroke (adjusted hazard ratio, 1.29 [0.97-1.71]; P =0.08) but similarly with cardiovascular events (1.41 [1.09-1.83]; P =0.009). BPV on awake ambulatory BP monitoring was nonpredictive (stroke: 0.89 [0.59-1.35]; P =0.59; cardiovascular events: 1.08 [0.77-1.52]; P =0.65). Despite a weak correlation ( r =0.119; P =0.02), beat-to-beat BPV was associated with risk of recurrent stroke independently of day-to-day BPV (1.41 [1.05-1.90]; P =0.02). Beat-to-beat BPV predicted recurrent stroke and cardiovascular events, independently of mean systolic BP and risk factors but short-term BPV on ambulatory BP monitoring did not. Beat-to-beat BPV may be a useful additional marker of cardiovascular risk. © 2017 The Authors.
Tamosuitis, Tomas; Pranskunas, Andrius; Balciuniene, Neringa; Pilvinis, Vidas; Boerma, E Christiaan
2016-07-11
The conjunctival microcirculation has potential as a window to cerebral perfusion due to related blood supply, close anatomical proximity and easy accessibility for microcirculatory imaging technique, such as sidestream dark field (SDF) imaging. Our study aims to evaluate conjunctival and sublingual microcirculation in brain dead patients and to compare it with healthy volunteers in two diametrically opposed conditions: full stop versus normal arterial blood supply to the brain. In a prospective observational study we analyzed conjunctival and sublingual microcirculation using SDF imaging in brain dead patients after reaching systemic hemodynamic targets to optimize perfusion of donor organs, and in healthy volunteers. All brain death diagnoses were confirmed by cerebral angiography. Microcirculatory images were obtained and analyzed using standardized published recommendations. Study registered at ClinicalTrials.gov, number NCT02483273. Eleven brain dead patients and eleven apparently healthy controls were enrolled in the study. Microvascular flow index (MFI) of small vessels was significantly lower in brain dead patients in comparison to healthy controls in ocular conjunctiva (2.7 [2.4-2.9] vs. 3.0 [2.9-3.0], p = 0.01) and in sublingual mucosa (2.8 [2.6-2.9] vs. 3.0 [2.9-3.0], p = 0.02). Total vessel density (TVD) and perfused vessel density (PVD) of small vessels were significantly lower in brain dead patients in comparison to healthy controls in ocular conjunctiva (10.2 [6.6-14.8] vs. 18.0 [18.0-25.4] mm/mm(2), p = 0.001 and 5.0 [3.5-7.3] vs. 10.9 [10.9-13.5] 1/mm, p = 0.001), but not in sublingual mucosa. In comparison to healthy controls brain dead patients had a significant reduction in conjunctival microvascular blood flow and density. However, the presence of conjunctival flow in case general cerebral flow is completely absent makes it impossible to use the conjunctival microcirculation as a substitute for brain flow, and further research should focus on the link between the ocular microcirculation, intracranial pressure and alternative ocular circulation.
Beliefs of Sri Lankan Medical Students about Wife Beating
ERIC Educational Resources Information Center
Haj-Yahia, Muhammad M.; de Zoysa, Piyanjali
2007-01-01
The article presents the results of a study on beliefs about wife beating conducted among 476 Sri Lankan medical students. Participants fill out a self-administered questionnaire, which examines six beliefs about wife beating. Most students tend to justify wife beating, to believe women benefit from wife beating, and to believe the wife bears more…
Smith predictor-based robot control for ultrasound-guided teleoperated beating-heart surgery.
Bowthorpe, Meaghan; Tavakoli, Mahdi; Becher, Harald; Howe, Robert
2014-01-01
Performing surgery on fast-moving heart structures while the heart is freely beating is next to impossible. Nevertheless, the ability to do this would greatly benefit patients. By controlling a teleoperated robot to continuously follow the heart's motion, the heart can be made to appear stationary. The surgeon will then be able to operate on a seemingly stationary heart when in reality it is freely beating. The heart's motion is measured from ultrasound images and thus involves a non-negligible delay due to image acquisition and processing, estimated to be 150 ms that, if not compensated for, can cause the teleoperated robot's end-effector (i.e., the surgical tool) to collide with and puncture the heart. This research proposes the use of a Smith predictor to compensate for this time delay in calculating the reference position for the teleoperated robot. The results suggest that heart motion tracking is improved as the introduction of the Smith predictor significantly decreases the mean absolute error, which is the error in making the distance between the robot's end-effector and the heart follow the surgeon's motion, and the mean integrated square error.
Keeping the Beat: A Large Sample Study of Bouncing and Clapping to Music
Tranchant, Pauline; Vuvan, Dominique T.; Peretz, Isabelle
2016-01-01
The vast majority of humans move in time with a musical beat. This behaviour has been mostly studied through finger-tapping synchronization. Here, we evaluate naturalistic synchronization responses to music–bouncing and clapping–in 100 university students. Their ability to match the period of their bounces and claps to those of a metronome and musical clips varying in beat saliency was assessed. In general, clapping was better synchronized with the beat than bouncing, suggesting that the choice of a specific movement type is an important factor to consider in the study of sensorimotor synchronization processes. Performance improved as a function of beat saliency, indicating that beat abstraction plays a significant role in synchronization. Fourteen percent of the population exhibited marked difficulties with matching the beat. Yet, at a group level, poor synchronizers showed similar sensitivity to movement type and beat saliency as normal synchronizers. These results suggest the presence of quantitative rather than qualitative variations when losing the beat. PMID:27471854
Midbrain adaptation may set the stage for the perception of musical beat
2017-01-01
The ability to spontaneously feel a beat in music is a phenomenon widely believed to be unique to humans. Though beat perception involves the coordinated engagement of sensory, motor and cognitive processes in humans, the contribution of low-level auditory processing to the activation of these networks in a beat-specific manner is poorly understood. Here, we present evidence from a rodent model that midbrain preprocessing of sounds may already be shaping where the beat is ultimately felt. For the tested set of musical rhythms, on-beat sounds on average evoked higher firing rates than off-beat sounds, and this difference was a defining feature of the set of beat interpretations most commonly perceived by human listeners over others. Basic firing rate adaptation provided a sufficient explanation for these results. Our findings suggest that midbrain adaptation, by encoding the temporal context of sounds, creates points of neural emphasis that may influence the perceptual emergence of a beat. PMID:29118141
Midbrain adaptation may set the stage for the perception of musical beat.
Rajendran, Vani G; Harper, Nicol S; Garcia-Lazaro, Jose A; Lesica, Nicholas A; Schnupp, Jan W H
2017-11-15
The ability to spontaneously feel a beat in music is a phenomenon widely believed to be unique to humans. Though beat perception involves the coordinated engagement of sensory, motor and cognitive processes in humans, the contribution of low-level auditory processing to the activation of these networks in a beat-specific manner is poorly understood. Here, we present evidence from a rodent model that midbrain preprocessing of sounds may already be shaping where the beat is ultimately felt. For the tested set of musical rhythms, on-beat sounds on average evoked higher firing rates than off-beat sounds, and this difference was a defining feature of the set of beat interpretations most commonly perceived by human listeners over others. Basic firing rate adaptation provided a sufficient explanation for these results. Our findings suggest that midbrain adaptation, by encoding the temporal context of sounds, creates points of neural emphasis that may influence the perceptual emergence of a beat. © 2017 The Authors.
Smith predictor with sliding mode control for processes with large dead times
NASA Astrophysics Data System (ADS)
Mehta, Utkal; Kaya, İbrahim
2017-11-01
The paper discusses the Smith Predictor scheme with Sliding Mode Controller (SP-SMC) for processes with large dead times. This technique gives improved load-disturbance rejection with optimum input control signal variations. A power rate reaching law is incorporated in the sporadic part of sliding mode control such that the overall performance recovers meaningfully. The proposed scheme obtains parameter values by satisfying a new performance index which is based on biobjective constraint. In simulation study, the efficiency of the method is evaluated for robustness and transient performance over reported techniques.
Coarse woody debris and soil respiration 6 years post-tornado in a Piedmont forest blowdown
NASA Astrophysics Data System (ADS)
Oldfield, C.; Peterson, C. J.
2017-12-01
Severe wind disturbances can rapidly change carbon pools and fluxes in forests, causing a site to switch from a carbon sink to a source in a matter of minutes. Moreover, salvage logging after a disturbance can result in disturbed and compacted soil, altered woody debris carbon pools, and seedling mortality, all of which may further alter carbon dynamics beyond that caused by the disturbance itself. We measured down dead wood and soil respiration in the summer of 2017 at Boggs Creek Recreation Area in the Piedmont of northeast Georgia, the site of a severe tornado in 2011. Down dead wood and soil respiration were compared in control (intact forest), salvaged, and unsalvaged areas. Megagrams per hectare of down dead wood was significantly higher in the unsalvaged condition than the control or salvage logging condition (ANOVAs, p<0.05 in both cases). Conversely, the volume of down dead wood was not significantly different in the control when compared to the salvage logging condition (p=0.99). Soil respiration was significantly higher in the salvage logged condition than the control (p<0.05), but was not significantly different between the unsalvaged condition and the control (p=0.30) or the unsalvaged condition and the salvaged condition (p=0.58). This research shows that wind disturbances have a lasting impact on the amount of down dead wood in a forest, and salvage logging may lead to greater soil respiration years after the initial disturbance, both of which will influence the time elapsed before a disturbed forest switches from carbon source to carbon sink. Further research is needed to determine the duration of these effects, along with the carbon consequences for other forest carbon pools.
A 15-year review of railway-related deaths in Jefferson County, Alabama.
Davis, G G; Alexander, C B; Brissie, R M
1997-12-01
A retrospective computer search of the records of the Jefferson County Coroner/Medical Examiner Office covering the 15-year period from 1981 to 1995 revealed 86 cases in which either a train caused death or in which a body was found dead by the tracks. The average age of the decedents was 39 years (range, 3 weeks-87 years). Men accounted for 88% of the deaths. The manners of death were as follows: three natural, 64 accident, seven suicide, six homicide, and six undetermined. Six decedents were found dead by the tracks, but death was not caused by a train. Six decedents were railroad employees who died on the job. In 47 cases, the decedents were trespassing on railroad property. Five trespassers were riding the rails, and 42 were pedestrians struck by a train. Motor vehicle collisions with trains claimed 27 lives--19 drivers and eight passengers. All together, 45% of the decedents were intoxicated. Intoxication was greatest by far in individuals witnessed to have been lying on the tracks before being hit by a train. The nature of individuals riding the rails has changed in the past few decades. Freight trains today are being used by illegal immigrants as transportation within the United States. The majority of traffic fatalities occurred because the driver intentionally tried to beat the train to the crossing. These drivers were seldom intoxicated, and only two were teenagers. Lives of such impatient drivers might be spared by the installation of a crossing guard-rail that cannot be circumvented.
Association between vitamin D levels and inflammatory activity in brain death: A prospective study.
Custódio, Geisiane; Schwarz, Patrícia; Crispim, Daisy; Moraes, Rafael B; Czepielewski, Mauro; Leitão, Cristiane B; Rech, Tatiana H
2018-06-01
Vitamin D insufficiency is linked to several common inflammatory disorders. Brain death (BD) causes a massive catecholamine release, leading to intense inflammatory activity. We aimed to evaluate vitamin D serum levels in brain-dead individuals in comparison to critically ill patients without BD to assess the correlation between vitamin D and cytokine levels. Sixteen brain-dead patients and 32 critically ill controls were prospectively enrolled. Blood samples from 25 brain-dead patients from a previous study were also used for vitamin D quantification. Plasma TNF, IL-1β, IL-6, IL-8, IL-10, IFN-γ and serum vitamin D levels were compared using Student's t-test or one-way ANOVA. Spearman's test was used to assess the correlation between vitamin D and cytokine levels. Mean vitamin D levels were 16.4 ± 7.9 ng/mL, with 52 patients (71.2%) classified as vitamin D deficient (serum levels < 20 ng/mL). Vitamin D levels were similar in 41 brain-dead patients as compared to control subjects (15.6 ± 6.9 ng/mL vs 17.4 ± 9.0 ng/mL; p = 0.383). Moderate direct correlations were observed between vitamin D and IL-8, IL-10, and IFN-γ in the prospective group of 16 brain-dead patients (IL-8: r = 0.5, p = 0.049; IL-10 r = 0.67, p = 0.005; IFN-γ r = 0.6, p = 0.015). Vitamin D was inversely correlated with IL-6 (r = -0.36, p = 0.044) in critically ill controls. Vitamin D serum levels were similarly low in brain-dead and critically ill patients. In brain-dead patients, vitamin D serum levels correlated with plasma IL-8, IL-10 and IFN-γ. Copyright © 2018 Elsevier B.V. All rights reserved.
Effect of dynamic exercise on human carotid-cardiac baroreflex latency
NASA Technical Reports Server (NTRS)
Potts, J. T.; Raven, P. B.
1995-01-01
We compared the beat-to-beat responses of heart rate (HR) after brief activation of carotid baroreceptors in resting humans with the responses obtained during mild-to-moderate levels of dynamic exercise [25 and 50% of peak O2 uptake (VO2peak)] to investigate the effect of exercise on baroreflex latency. Carotid baroreceptors were activated by a pressure pulse (5 s) of neck suction (NS, -80 Torr) and neck pressure (NP, +40 Torr) during held expiration. At rest the peak change in HR to NS/NP occurred during the first several heartbeats (1st-3rd beat), whereas during mild and moderate exercise peak HR responses occurred near the end of the NS/NP pulse (6th-8th beat). In contrast, time (s) to the peak change in HR was not different between rest and exercise (P > 0.05). Reflex tachycadia to NP progressively decreased during exercise (17 +/- 3, 10 +/- 1, and 4 +/- 1% of control, rest vs. 25% VO2peak, vs. 50% VO2peak, respectively, P < 0.05), and a strong positive correlation was found between the magnitude of the reflex tachycardia and a measure of HR variability (cardiac vagal tone index, r = 0.74, P < 0.0001). Reflex bradycardia to NS gradually increased during exercise (13 +/- 2, 17 +/- 2, and 18 +/- 2% of control, rest vs. 25% VO2peak, vs. 50% VO2peak, respectively, P = 0.10) and was negatively correlated with cardiac vagal tone (r = 0.42, P < 0.06).(ABSTRACT TRUNCATED AT 250 WORDS).
Frequency-modulated laser ranging sensor with closed-loop control
NASA Astrophysics Data System (ADS)
Müller, Fabian M.; Böttger, Gunnar; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Schröder, Henning; Schneider-Ramelow, Martin
2018-02-01
Advances in autonomous driving and robotics are creating high demand for inexpensive and mass-producible distance sensors. A laser ranging system (Lidar), based on the frequency-modulated continuous-wave (FMCW) method is built in this work. The benefits of an FMCW Lidar system are the low-cost components and the performance in comparison to conventional time-of-flight Lidar systems. The basic system consists of a DFB laser diode (λ= 1308 nm) and an asymmetric fiber-coupled Mach-Zehnder interferometer with a fixed delay line in one arm. Linear tuning of the laser optical frequency via injection current modulation creates a beat signal at the interferometer output. The frequency of the beat signal is proportional to the optical path difference in the interferometer. Since the laser frequency-to-current response is non-linear, a closed-loop feed-back system is designed to improve the tuning linearity, and consequently the measurement resolution. For fast active control, an embedded system with FPGA is used, resulting in a nearly linear frequency tuning, realizing a narrow peak in the Fourier spectrum of the beat signal. For free-space measurements, a setup with two distinct interferometers is built. The fully fiber-coupled Mach-Zehnder reference interferometer is part of the feed-back loop system, while the other - a Michelson interferometer - has a free-space arm with collimator lens and reflective target. A resolution of 2:0 mm for a 560 mm distance is achieved. The results for varying target distances show high consistency and a linear relation to the measured beat-frequency.
NASA Astrophysics Data System (ADS)
Ugon, B.; Nandong, J.; Zang, Z.
2017-06-01
The presence of unstable dead-time systems in process plants often leads to a daunting challenge in the design of standard PID controllers, which are not only intended to provide close-loop stability but also to give good performance-robustness overall. In this paper, we conduct stability analysis on a double-loop control scheme based on the Routh-Hurwitz stability criteria. We propose to use this unstable double-loop control scheme which employs two P/PID controllers to control first-order or second-order unstable dead-time processes typically found in process industries. Based on the Routh-Hurwitz stability necessary and sufficient criteria, we establish several stability regions which enclose within them the P/PID parameter values that guarantee close-loop stability of the double-loop control scheme. A systematic tuning rule is developed for the purpose of obtaining the optimal P/PID parameter values within the established regions. The effectiveness of the proposed tuning rule is demonstrated using several numerical examples and the result are compared with some well-established tuning methods reported in the literature.
Flethøj, Mette; Kanters, Jørgen K; Pedersen, Philip J; Haugaard, Maria M; Carstensen, Helena; Olsen, Lisbeth H; Buhl, Rikke
2016-11-28
Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to determine the appropriate threshold levels of maximum acceptable deviation of RR intervals in equine ECG analysis, and to evaluate a novel two-step timing algorithm by quantifying the frequency of arrhythmias in a cohort of healthy adult endurance horses. Beat-to-beat variation differed considerably with heart rate (HR), and an adaptable model consisting of three different HR ranges with separate threshold levels of maximum acceptable RR deviation was consequently defined. For resting HRs <60 beats/min (bpm) the threshold level of RR deviation was set at 20%, for HRs in the intermediate range between 60 and 100 bpm the threshold was 10%, and for exercising HRs >100 bpm, the threshold level was 4%. Supraventricular premature beats represented the most prevalent arrhythmia category with varying frequencies in seven horses at rest (median 7, range 2-86) and six horses during exercise (median 2, range 1-24). Beat-to-beat variation of equine cardiac rhythm varies according to HR, and threshold levels in equine ECG analysis should be adjusted accordingly. Standardization of the analysis criteria will enable comparisons of studies and follow-up examinations of patients. A small number of supraventricular premature beats appears to be a normal finding in endurance horses. Further studies are required to validate the findings and determine the clinical significance of premature beats in horses.
Rani, Manju; Bonu, Sekhar; Diop-Sidibe, Nafissatou
2004-12-01
This study used data from the demographic and health surveys (DHS) conducted between 1999 and 2001 in Benin, Ethiopia, Malawi, Mali, Rwanda, Uganda and Zimbabwe, to examine the magnitude and correlates of conditional acceptance of wife-beating among both men and women. Multivariate logistic regression models were fitted to investigate the independent association between different socio-demographic characteristics and acceptance of wife-beating. The acceptance of wife-beating for transgressing certain gender roles was widespread in all the countries. Men were consistently less likely to justify wife-beating than women. Household wealth and education emerged as strongest and most consistent negative predictors of acceptance of wife-beating among both men and women. Older men and women were less likely to justify wife-beating. Men and women in the polygamous union were more likely to accept wife-beating, though the association was not always significant. With the exception of Uganda, women working for pay were more likely to justify wife-beating than non-working women were. The results indicate that dominant social and cultural norms create images of "ideal" women among both men and women that include definition and widespread acceptance of gender roles as well as sanction use of force to enforce these gender roles. The State and its different institutions may fail to mitigate wife-beating, as sensitivity to objectively address wife-beating may be tellingly lacking. Though education, economic growth, etc, can reduce acceptance of wife-beating, the process may be too slow and too late to make a substantial difference in the near future. Proactive measures may be required to change attitudes towards wife-beating among both men and women.
Aljiffry, M; Hassanain, M; Schricker, T; Shaheen, M; Nouh, T; Lattermann, R; Salman, A; Wykes, L; Metrakos, P
2016-05-01
Brain death is a major stress that is associated with a massive inflammatory response and systemic hyperglycemia. Severe inflammation leads to increased graft immunogenicity and risk of graft dysfunction; while acute hyperglycemia aggravates the inflammatory response and increases the risk of morbidity and mortality. Insulin therapy not only controls hyperglycemia but also suppresses inflammation. The present study is to investigate the anti-inflammatory properties and the normoglycemia maintenance of high dose insulin on brain dead organ donors. 15 brain dead organ donors were divided into 2 groups, insulin treated (n=6) and controls (n=9). Insulin was provided for a minimum of 6 h using the hyperinsulinemic normoglycemic clamp technique. The changes of serum cytokines, including IL-6, IL-10, IL-1β, IL-8, TNFα, TGFα and MCP-1, were measured by suspension bead array immunoassay and glucose by a glucose monitor. Compared to controls, insulin treated donors had a significant lower blood glucose 4.8 (4-6.9) vs. 9 (5.6-11.7) mmol/L, p<0.01); the net decreases of pro-inflammatory cytokines, such as IL-6 and MCP-1, and the net increase of anti-inflammatory cytokine, such as IL-10, reached significant level in insulin treated donors compared with those in controls. High dose insulin therapy decreases the concentrations of inflammatory cytokines in brain dead donors and preserves normoglycemia. High dose of insulin may have anti-inflammatory effects in brain dead organ donors and therefore, improve the quality of donor organs and potentially improve outcomes. © Georg Thieme Verlag KG Stuttgart · New York.
Enami, Yuta; Joseph, Brigid; Bandi, Sriram; Lin, Juan; Gupta, Sanjeev
2012-04-01
Organs from non-heart-beating donors are attractive for use in cell therapy. Understanding the nature of molecular perturbations following reperfusion/reoxygenation will be highly significant for non-heart-beating donor cells. We studied non-heart-beating donor rats for global gene expression with Affymetrix microarrays, hepatic tissue integrity, viability of isolated hepatocytes, and engraftment and proliferation of transplanted cells in dipeptidyl peptidase IV-deficient rats. In non-heart-beating donors, liver tissue was morphologically intact for >24 hours with differential expression of 1, 95, or 372 genes, 4, 16, or 34 hours after death, respectively, compared with heart-beating donors. These differentially expressed genes constituted prominent groupings in ontological pathways of oxidative phosphorylation, adherence junctions, glycolysis/gluconeogenesis, and other discrete pathways. We successfully isolated viable hepatocytes from non-heart-beating donors, especially up to 4 hours after death, although the hepatocyte yield and viability were inferior to those of hepatocytes from heart-beating donors (P < 0.05). Similarly, although hepatocytes from non-heart-beating donors engrafted and proliferated after transplantation in recipient animals, this was inferior to hepatocytes from heart-beating donors (P < 0.05). Gene expression profiling in hepatocytes isolated from non-heart-beating donors showed far greater perturbations compared with corresponding liver tissue, including representation of pathways in focal adhesion, actin cytoskeleton, extracellular matrix-receptor interactions, multiple ligand-receptor interactions, and signaling in insulin, calcium, wnt, Jak-Stat, or other cascades. Liver tissue remained intact over prolonged periods after death in non-heart-beating donors, but extensive molecular perturbations following reperfusion/reoxygenation impaired the viability of isolated hepatocytes from these donors. Insights into molecular changes in hepatocytes from non-heart-beating donors offer opportunities for improving donor cell viability, which will advance the utility of non-heart-beating donor organs for cell therapy or other applications. Copyright © 2012 American Association for the Study of Liver Diseases.
Klass, Dennis; Goss, Robert
2003-11-01
The article is a contribution to a cross-cultural theory of grief. It examines the relationship between individual/family continuing bonds with the dead and cultural narratives that legitimize political power. The dead are collective representations (Dirkheim) that mediate the larger culture to individuals and to smaller communities and that reinforce social solidarity and identity. The political question is which collective--family, community, church, party, nation--owns the dead and controls the rituals by which bonds with the dead are maintained or relinquished? The article discusses one historical condition: times of rapid change in power arrangements. Bonds with the dead have a power in individual, family, or tribal life that can threaten the narrative that legitimizes the new political power holders. Ancestor rituals that support identity as a family or tribal member are surpressed and replaced by allegiance to collective representations of the new political order. Two historical examples are given: China under Chairman Mao and the Wahhabi reform in Arabic Islam.
Effects of creatine supplementation on cardiac autonomic functions in bodybuilders.
Mert, Kadir Uğur; Ilgüy, Serdar; Dural, Muhammet; Mert, Gurbet Özge; Özakin, Engin
2017-06-01
Bodybuilder-type workouts may affect heart rate variability (HRV), which has considerable potential to assess the role of autonomic nervous system (ANS). A scientifically designed approach is necessary for bodybuilders to achieve better results while protecting their health. In this study, we aimed to investigate HRV parameters in bodybuilders compared to healthy control subjects and effects of creatine supplementation. A total of 48 male participants (16 controls, 16 supplement (-), 16 supplement (+)) were evaluated in our study. Bodybuilders who were taking creatine supplementation were enrolled in supplement (+) group. HRV parameters were measured from 24-hour Holter recordings of all participants. When mean heart rates were compared with control group (71.5 ± 12.6 beats/min), statistically significant difference was revealed in supplement (-) group (61.8 ± 6.8 beats/min; P = 0.022) unlike supplement (+) group (69.63 ± 14.1 beats/min; P = 0.650). HRV analyses revealed significant parasympathetic shift in supplement (-) group. No significant difference was demonstrated on HRV parameters, except high frequency (P = 0.029) in supplement (+) group. Conclusively, elevated parasympathetic modulation, which is favorable cardiovascular outcome of exercise, was demonstrated in bodybuilders. However, our study also revealed that creatine supplementation attenuates this favorable effect in ANS by limiting elevation of parasympathetic modulation. Although the sympathetic slight shift is attributed to creatine supplementation, it cannot be discriminated from the effects of over training. © 2017 Wiley Periodicals, Inc.
Brainstem Encoding of Aided Speech in Hearing Aid Users with Cochlear Dead Region(s).
Hassaan, Mohammad Ramadan; Ibraheem, Ola Abdallah; Galhom, Dalia Helal
2016-07-01
Neural encoding of speech begins with the analysis of the signal as a whole broken down into its sinusoidal components in the cochlea, which has to be conserved up to the higher auditory centers. Some of these components target the dead regions of the cochlea causing little or no excitation. Measuring aided speech-evoked auditory brainstem response elicited by speech stimuli with different spectral maxima can give insight into the brainstem encoding of aided speech with spectral maxima at these dead regions. This research aims to study the impact of dead regions of the cochlea on speech processing at the brainstem level after a long period of hearing aid use. This study comprised 30 ears without dead regions and 46 ears with dead regions at low, mid, or high frequencies. For all ears, we measured the aided speech-evoked auditory brainstem response using speech stimuli of low, mid, and high spectral maxima. Aided speech-evoked auditory brainstem response was producible in all subjects. Responses evoked by stimuli with spectral maxima at dead regions had longer latencies and smaller amplitudes when compared with the control group or the responses of other stimuli. The presence of cochlear dead regions affects brainstem encoding of speech with spectral maxima perpendicular to these regions. Brainstem neuroplasticity and the extrinsic redundancy of speech can minimize the impact of dead regions in chronic hearing aid users.
Mancia, Claire; Loustaud-Ratti, Véronique; Carrier, Paul; Naudet, Florian; Bellissant, Eric; Labrousse, François; Pichon, Nicolas
2015-08-01
One of the main selection criteria of the quality of a liver graft is the degree of steatosis, which will determine the success of the transplantation. The aim of this study was to evaluate the ability of FibroScan and its related methods Controlled Attenuation Parameter and Liver Stiffness to assess objectively steatosis and fibrosis in livers from brain-dead donors to be potentially used for transplantation. Over a period of 10 months, 23 consecutive brain dead donors screened for liver procurement underwent a FibroScan and a liver biopsy. The different predictive models of liver retrievability using liver biopsy as the gold standard have led to the following area under receiver operating characteristic curve: 76.6% (95% confidence intervals [95% CIs], 48.2%-100%) when based solely on controlled attenuation parameter, 75.0% (95% CIs, 34.3%-100%) when based solely on liver stiffness, and 96.7% (95% CIs, 88.7%-100%) when based on combined indices. Our study suggests that a preoperative selection of brain-dead donors based on a combination of both Controlled Attenuation Parameter and Liver Stiffness obtained with FibroScan could result in a good preoperative prediction of the histological status and degree of steatosis of a potential liver graft.
Muris, Peter; Mayer, Birgit; Bervoets, Sabine
2010-08-01
The present study investigated anxiety-related emotional reasoning in 9-13-year-old children using an experimental approach. Eighty-one children completed a computerized ambiguous situations test for assessing their perception of threat under two conditions. In the experimental condition, children were attached to an apparatus that allegedly recorded their heart beat, the sound of which was presented to them via headphones. In the control condition, children listened to the sound of an African djembe drum while completing the ambiguous situations test. It was found that children in the experimental condition generally provided higher threat ratings than children in the control condition, and this difference remained significant when controlling for levels of anxiety sensitivity, panic and other anxiety symptoms. These results are in keeping with the idea that children may partially rely on internal physical sensations when evaluating the dangerousness of ambiguous events. (c) 2010 Elsevier Ltd. All rights reserved.
Sartori, Pablo; Geyer, Veikko F; Scholich, Andre; Jülicher, Frank; Howard, Jonathon
2016-01-01
Cilia and flagella are model systems for studying how mechanical forces control morphology. The periodic bending motion of cilia and flagella is thought to arise from mechanical feedback: dynein motors generate sliding forces that bend the flagellum, and bending leads to deformations and stresses, which feed back and regulate the motors. Three alternative feedback mechanisms have been proposed: regulation by the sliding forces, regulation by the curvature of the flagellum, and regulation by the normal forces that deform the cross-section of the flagellum. In this work, we combined theoretical and experimental approaches to show that the curvature control mechanism is the one that accords best with the bending waveforms of Chlamydomonas flagella. We make the surprising prediction that the motors respond to the time derivative of curvature, rather than curvature itself, hinting at an adaptation mechanism controlling the flagellar beat. DOI: http://dx.doi.org/10.7554/eLife.13258.001 PMID:27166516
Dynamic characteristics of heart rate control by the autonomic nervous system in rats.
Mizuno, Masaki; Kawada, Toru; Kamiya, Atsunori; Miyamoto, Tadayoshi; Shimizu, Shuji; Shishido, Toshiaki; Smith, Scott A; Sugimachi, Masaru
2010-09-01
We estimated the transfer function of autonomic heart rate (HR) control by using random binary sympathetic or vagal nerve stimulation in anaesthetized rats. The transfer function from sympathetic stimulation to HR response approximated a second-order, low-pass filter with a lag time (gain, 4.29 +/- 1.55 beats min(1) Hz(1); natural frequency, 0.07 +/- 0.03 Hz; damping coefficient, 1.96 +/- 0.64; and lag time, 0.73 +/- 0.12 s). The transfer function from vagal stimulation to HR response approximated a first-order, low-pass filter with a lag time (gain, 8.84 +/- 4.51 beats min(1) Hz(1); corner frequency, 0.12 +/- 0.06 Hz; and lag time, 0.12 +/- 0.08 s). These results suggest that the dynamic characteristics of HR control by the autonomic nervous system in rats are similar to those of larger mammals.
Increased beat-to-beat T-wave variability in myocardial infarction patients.
Hasan, Muhammad A; Abbott, Derek; Baumert, Mathias; Krishnan, Sridhar
2018-03-28
The purpose of this study was to investigate the beat-to-beat variability of T-waves (TWV) and to assess the diagnostic capabilities of T-wave-based features for myocardial infarction (MI). A total of 148 recordings of standard 12-lead electrocardiograms (ECGs) from 79 MI patients (22 females, mean age 63±12 years; 57 males, mean age 57±10 years) and 69 recordings from healthy subjects (HS) (17 females, 42±18 years; 52 males, 40±13 years) were studied. For the quantification of beat-to-beat QT intervals in ECG signal, a template-matching algorithm was applied. To study the T-waves beat-to-beat, we measured the angle between T-wave max and T-wave end with respect to Q-wave (∠α) and T-wave amplitudes. We computed the standard deviation (SD) of beat-to-beat T-wave features and QT intervals as markers of variability in T-waves and QT intervals, respectively, for both patients and HS. Moreover, we investigated the differences in the studied features based on gender and age for both groups. Significantly increased TWV and QT interval variability (QTV) were found in MI patients compared to HS (p<0.05). No significant differences were observed based on gender or age. TWV may have some diagnostic attributes that may facilitate identifying patients with MI. In addition, the proposed beat-to-beat angle variability was found to be independent of heart rate variations. Moreover, the proposed feature seems to have higher sensitivity than previously reported feature (QT interval and T-wave amplitude) variability for identifying patients with MI.
Significance of beating observed in earthquake responses of buildings
Çelebi, Mehmet; Ghahari, S. F.; Taciroglu, E.
2016-01-01
The beating phenomenon observed in the recorded responses of a tall building in Japan and another in the U.S. are examined in this paper. Beating is a periodic vibrational behavior caused by distinctive coupling between translational and torsional modes that typically have close frequencies. Beating is prominent in the prolonged resonant responses of lightly damped structures. Resonances caused by site effects also contribute to accentuating the beating effect. Spectral analyses and system identification techniques are used herein to quantify the periods and amplitudes of the beating effects from the strong motion recordings of the two buildings. Quantification of beating effects is a first step towards determining remedial actions to improve resilient building performance to strong earthquake induced shaking.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, III, Robert A. (Inventor)
1996-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
Neural entrainment to the rhythmic structure of music.
Tierney, Adam; Kraus, Nina
2015-02-01
The neural resonance theory of musical meter explains musical beat tracking as the result of entrainment of neural oscillations to the beat frequency and its higher harmonics. This theory has gained empirical support from experiments using simple, abstract stimuli. However, to date there has been no empirical evidence for a role of neural entrainment in the perception of the beat of ecologically valid music. Here we presented participants with a single pop song with a superimposed bassoon sound. This stimulus was either lined up with the beat of the music or shifted away from the beat by 25% of the average interbeat interval. Both conditions elicited a neural response at the beat frequency. However, although the on-the-beat condition elicited a clear response at the first harmonic of the beat, this frequency was absent in the neural response to the off-the-beat condition. These results support a role for neural entrainment in tracking the metrical structure of real music and show that neural meter tracking can be disrupted by the presentation of contradictory rhythmic cues.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, Robert A., III (Inventor)
1994-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate is presented. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
Lac Qui Parle Flood Control Project Master Plan for Public Use Development and Resource Management.
1980-08-01
the project area is the disposal of dead carp. Minnesota fishing regulations prohibit fishermen from returning rough fish to lakes or rivers after...in trash cans. Unless the dead fish are removed virtually daily, they begin to decompose and smell. Due to current work- force constraints, the Corps...is unable to remove the dead fish as often as it would like. No easy solution to this problem is apparent. 6.25 Potential for Future Development The
Davidow, Jason H
2014-01-01
Metronome-paced speech results in the elimination, or substantial reduction, of stuttering moments. The cause of fluency during this fluency-inducing condition is unknown. Several investigations have reported changes in speech pattern characteristics from a control condition to a metronome-paced speech condition, but failure to control speech rate between conditions limits our ability to determine if the changes were necessary for fluency. This study examined the effect of speech rate on several speech production variables during one-syllable-per-beat metronomic speech in order to determine changes that may be important for fluency during this fluency-inducing condition. Thirteen persons who stutter (PWS), aged 18-62 years, completed a series of speaking tasks. Several speech production variables were compared between conditions produced at different metronome beat rates, and between a control condition and a metronome-paced speech condition produced at a rate equal to the control condition. Vowel duration, voice onset time, pressure rise time and phonated intervals were significantly impacted by metronome beat rate. Voice onset time and the percentage of short (30-100 ms) phonated intervals significantly decreased from the control condition to the equivalent rate metronome-paced speech condition. A reduction in the percentage of short phonated intervals may be important for fluency during syllable-based metronome-paced speech for PWS. Future studies should continue examining the necessity of this reduction. In addition, speech rate must be controlled in future fluency-inducing condition studies, including neuroimaging investigations, in order for this research to make a substantial contribution to finding the fluency-inducing mechanism of fluency-inducing conditions. © 2013 Royal College of Speech and Language Therapists.
Davidow, Jason H.
2013-01-01
Background Metronome-paced speech results in the elimination, or substantial reduction, of stuttering moments. The cause of fluency during this fluency-inducing condition is unknown. Several investigations have reported changes in speech pattern characteristics from a control condition to a metronome-paced speech condition, but failure to control speech rate between conditions limits our ability to determine if the changes were necessary for fluency. Aims This study examined the effect of speech rate on several speech production variables during one-syllable-per-beat metronomic speech, in order to determine changes that may be important for fluency during this fluency-inducing condition. Methods and Procedures Thirteen persons who stutter (PWS), aged 18–62 years, completed a series of speaking tasks. Several speech production variables were compared between conditions produced at different metronome beat rates, and between a control condition and a metronome-paced speech condition produced at a rate equal to the control condition. Outcomes & Results Vowel duration, voice onset time, pressure rise time, and phonated intervals were significantly impacted by metronome beat rate. Voice onset time and the percentage of short (30–100 ms) phonated intervals significantly decreased from the control condition to the equivalent rate metronome-paced speech condition. Conclusions & Implications A reduction in the percentage of short phonated intervals may be important for fluency during syllable-based metronome-paced speech for PWS. Future studies should continue examining the necessity of this reduction. In addition, speech rate must be controlled in future fluency-inducing condition studies, including neuroimaging investigations, in order for this research to make a substantial contribution to finding the fluency-inducing mechanism of fluency-inducing conditions. PMID:24372888
Belgian modified classification of Maastricht for donors after circulatory death.
Evrard, P
2014-11-01
"Non-heart-beating donors," or, in a more recent and international definition, "donors after circulatory death," are a potential and additional group of deceased persons who are able to add organs to the pool. A new classification is proposed on the basis of the result of a consensus of experts issued from all Belgian transplant centers. The first level of definition is simple and based on whether the situation is uncontrolled (categories I and II) or controlled (categories III, IV, and V). In category I, the patient is declared "dead on arrival" and, in category II, there is an "unsuccessful resuscitation" whether it occurred out or in the hospital for both situations. Category III is the most usual situation in which the treating physician and family are "awaiting cardiac arrest" to declare the death of the patient. Category IV is always characterized by "cardiac arrest during brain death." The special situation of the Belgian law allowing the euthanasia is elaborated in category V, "euthanasia," and includes patients who grant access to medically assisted circulatory death. Organ donation after euthanasia is allowed under the scope of donation after circulatory death. This classification conserves the skeleton of the Maastricht one, as it is simple and clear, but classifies easily the different donors after circulatory death types by processes for ethical issues and for the non-medical or non-specialized reader interested in the field. This is also an argument for public consideration and trust in the difficult field of organ donation.
Size-dependent control of colloid transport via solute gradients in dead-end channels
Shin, Sangwoo; Um, Eujin; Sabass, Benedikt; Ault, Jesse T.; Rahimi, Mohammad; Warren, Patrick B.; Stone, Howard A.
2016-01-01
Transport of colloids in dead-end channels is involved in widespread applications including drug delivery and underground oil and gas recovery. In such geometries, Brownian motion may be considered as the sole mechanism that enables transport of colloidal particles into or out of the channels, but it is, unfortunately, an extremely inefficient transport mechanism for microscale particles. Here, we explore the possibility of diffusiophoresis as a means to control the colloid transport in dead-end channels by introducing a solute gradient. We demonstrate that the transport of colloidal particles into the dead-end channels can be either enhanced or completely prevented via diffusiophoresis. In addition, we show that size-dependent diffusiophoretic transport of particles can be achieved by considering a finite Debye layer thickness effect, which is commonly ignored. A combination of diffusiophoresis and Brownian motion leads to a strong size-dependent focusing effect such that the larger particles tend to concentrate more and reside deeper in the channel. Our findings have implications for all manners of controlled release processes, especially for site-specific delivery systems where localized targeting of particles with minimal dispersion to the nontarget area is essential. PMID:26715753
Simulation of Satellite Vibration Test
NASA Astrophysics Data System (ADS)
Bettacchioli, Alain
2014-06-01
During every mechanical qualification test of satellites on vibrator, we systematically notice beating phenomena that appear every time we cross a mode's frequency. There could lead to an over-qualification of the tested specimen when the beating reaches a maximum and a under-qualification when the beating passes by a minimum. On a satellite, three lateral modes raise such a problem in a recurring way: the first structure mode (between 10 and 15 hertz) and the two tanks modes (between 35 and 50 hertz).To step forward in the resolution of this problem, we are developing a simulator which is based on the identification of the responses of the accelerometers that are fixed on the satellite and on the shaker slip table. The estimated transfer functions then allow to reconstruct at once the sensors response and the drive which generated them.For the simulation, we do not select all the sensors but only those on the slip table and those used to limit the input level (notching). We may also add those which were close to generate a notching.To perform its calculations, the simulator reproduces on one hand the unity amplitude signal (cola) which serves as frequency reference for the sweep achievement (generally 3 octaves per minute from 5 to 100 and even 150 Hertz), and on the other hand, the vibrator control loop. The drive amplitude is calculated at each cola's period by taking into account a compression factor. The control applied through the amplifier to the shaker coil is the product of this amplitude by the cola. The simulated measurements are updated at each sampling period thanks to the propagation of the identified model. The superposition of these curves on those supplied by real sensors during the tests allows to validate the simulation.Thereby, it seems possible to actively control the beatings thanks to a real-time corrector which uses these identifications.
Ali, Wail; Bubolz, Beth A; Nguyen, Linh; Castro, Danny; Coss-Bu, Jorge; Quach, Michael M; Kennedy, Curtis E; Anderson, Anne E; Lai, Yi-Chen
2017-12-01
Convulsive status epilepticus can exert profound cardiovascular effects in adults including ventricular depolarization-repolarization abnormalities. Whether status epilepticus adversely affects ventricular electrical properties in children is less understood. Therefore, we sought to characterize ventricular alterations and the associated clinical factors in children following convulsive status epilepticus. We conducted a 2-year retrospective, case-control study. Children between 1 month and 21 years of age were included if they were admitted to the pediatric intensive care unit with primary diagnosis of convulsive status epilepticus and had 12-lead electrocardiogram (ECG) within 24 hours of admission. Children with heart disease, ion channelopathy, or on vasoactive medications were excluded. Age-matched control subjects had no history of seizures or epilepsy. The primary outcome was ventricular abnormalities represented by ST segment changes, abnormal T wave, QRS axis deviation, and corrected QT (QTc) interval prolongation. The secondary outcomes included QT/RR relationship, beat-to-beat QTc interval variability, ECG interval measurement between groups, and clinical factors associated with ECG abnormalities. Of 317 eligible children, 59 met the inclusion criteria. History of epilepsy was present in 31 children (epileptic) and absent in 28 children (non-epileptic). Compared with the control subjects (n = 31), the status epilepticus groups were more likely to have an abnormal ECG with overall odds ratio of 3.8 and 7.0 for the non-epileptic and the epileptic groups respectively. Simple linear regression analysis demonstrated that children with epilepsy exhibited impaired dependence and adaptation of the QT interval on heart rate. Beat-to-beat QTc interval variability, a marker of ventricular repolarization instability, was increased in children with epilepsy. Convulsive status epilepticus can adversely affect ventricular electrical properties and stability in children, especially those with epilepsy. These findings suggest that children with epilepsy may be particularly vulnerable to seizure-induced arrhythmias. Therefore postictal cardiac surveillance may be warranted in this population.
Baroreflex modulation of sympathetic nerve activity to muscle in heat-stressed humans
NASA Technical Reports Server (NTRS)
Cui, Jian; Wilson, Thad E.; Crandall, Craig G.
2002-01-01
To identify whether whole body heating alters arterial baroreflex control of muscle sympathetic nerve activity (MSNA), MSNA and beat-by-beat arterial blood pressure were recorded in seven healthy subjects during acute hypotensive and hypertensive stimuli in both normothermic and heat stress conditions. Whole body heating significantly increased sublingual temperature (P < 0.01), MSNA (P < 0.01), heart rate (P < 0.01), and skin blood flow (P < 0.001), whereas mean arterial blood pressure did not change significantly (P > 0.05). During both normothermic and heat stress conditions, MSNA increased and then decreased significantly when blood pressure was lowered and then raised via intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure during heat stress (-128.3 +/- 13.9 U x beats(-1) x mmHg(-1)) was similar (P = 0.31) with normothermia (-140.6 +/- 21.1 U x beats(-1) x mmHg(-1)). Moreover, no significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. These data suggest that arterial baroreflex modulation of MSNA and heart rate are not altered by whole body heating, with the exception of an upward shift of these baroreflex curves to accommodate changes in these variables that occur with whole body heating.
Hua, Changchun; Zhang, Liuliu; Guan, Xinping
2017-01-01
This paper studies the problem of distributed output tracking consensus control for a class of high-order stochastic nonlinear multiagent systems with unknown nonlinear dead-zone under a directed graph topology. The adaptive neural networks are used to approximate the unknown nonlinear functions and a new inequality is used to deal with the completely unknown dead-zone input. Then, we design the controllers based on backstepping method and the dynamic surface control technique. It is strictly proved that the resulting closed-loop system is stable in probability in the sense of semiglobally uniform ultimate boundedness and the tracking errors between the leader and the followers approach to a small residual set based on Lyapunov stability theory. Finally, two simulation examples are presented to show the effectiveness and the advantages of the proposed techniques.
Individual Differences in Beat Perception Affect Gait Responses to Low- and High-Groove Music
Leow, Li-Ann; Parrott, Taylor; Grahn, Jessica A.
2014-01-01
Slowed gait in patients with Parkinson’s disease (PD) can be improved when patients synchronize footsteps to isochronous metronome cues, but limited retention of such improvements suggest that permanent cueing regimes are needed for long-term improvements. If so, music might make permanent cueing regimes more pleasant, improving adherence; however, music cueing requires patients to synchronize movements to the “beat,” which might be difficult for patients with PD who tend to show weak beat perception. One solution may be to use high-groove music, which has high beat salience that may facilitate synchronization, and affective properties, which may improve motivation to move. As a first step to understanding how beat perception affects gait in complex neurological disorders, we examined how beat perception ability affected gait in neurotypical adults. Synchronization performance and gait parameters were assessed as healthy young adults with strong or weak beat perception synchronized to low-groove music, high-groove music, and metronome cues. High-groove music was predicted to elicit better synchronization than low-groove music, due to its higher beat salience. Two musical tempi, or rates, were used: (1) preferred tempo: beat rate matched to preferred step rate and (2) faster tempo: beat rate adjusted to 22.5% faster than preferred step rate. For both strong and weak beat-perceivers, synchronization performance was best with metronome cues, followed by high-groove music, and worst with low-groove music. In addition, high-groove music elicited longer and faster steps than low-groove music, both at preferred tempo and at faster tempo. Low-groove music was particularly detrimental to gait in weak beat-perceivers, who showed slower and shorter steps compared to uncued walking. The findings show that individual differences in beat perception affect gait when synchronizing footsteps to music, and have implications for using music in gait rehabilitation. PMID:25374521
Zule, William A; Cross, Harry E; Stover, John; Pretorius, Carel
2013-01-01
Circumstantial evidence from laboratory studies, mathematical models, ecological studies and bio behavioural surveys, suggests that injection-related HIV epidemics may be averted or reversed if people who inject drugs (PWID) switch from using high dead-space to using low dead-space syringes. In laboratory experiments that simulated the injection process and rinsing with water, low dead space syringes retained 1000 times less blood than high dead space syringes. In mathematical models, switching PWID from high dead space to low dead space syringes prevents or reverses injection-related HIV epidemics. No one knows if such an intervention is feasible or what effect it would have on HIV transmission among PWID. Feasibility studies and randomized controlled trials (RCTs) will be needed to answer these questions definitively, but these studies will be very expensive and take years to complete. Rather than waiting for them to be completed, we argue for an approach similar to that used with needle and syringe programs (NSP), which were promoted and implemented before being tested more rigorously. Before implementation, rapid assessments that involve PWID will need to be conducted to ensure buy-in from PWID and other local stakeholders. This commentary summarizes the existing evidence regarding the protective effects of low dead space syringes and estimates potential impacts on HIV transmission; it describes potential barriers to transitioning PWID from high dead space to low dead space needles and syringes; and it presents strategies for overcoming these barriers. Copyright © 2012 Elsevier B.V. All rights reserved.
Detrended fluctuation analysis of non-stationary cardiac beat-to-beat interval of sick infants
NASA Astrophysics Data System (ADS)
Govindan, Rathinaswamy B.; Massaro, An N.; Al-Shargabi, Tareq; Niforatos Andescavage, Nickie; Chang, Taeun; Glass, Penny; du Plessis, Adre J.
2014-11-01
We performed detrended fluctuation analysis (DFA) of cardiac beat-to-beat intervals (RRis) collected from sick newborn infants over 1-4 day periods. We calculated four different metrics from the DFA fluctuation function: the DFA exponents αL (>40 beats up to one-fourth of the record length), αs (15-30 beats), root-mean-square (RMS) fluctuation on a short-time scale (20-50 beats), and RMS fluctuation on a long-time scale (110-150 beats). Except αL , all metrics clearly distinguished two groups of newborn infants (favourable vs. adverse) with well-characterized outcomes. However, the RMS fluctuations distinguished the two groups more consistently over time compared to αS . Furthermore, RMS distinguished the RRi of the two groups earlier compared to the DFA exponent. In all the three measures, the favourable outcome group displayed higher values, indicating a higher magnitude of (auto-)correlation and variability, thus normal physiology, compared to the adverse outcome group.
Ectopic beats in approximate entropy and sample entropy-based HRV assessment
NASA Astrophysics Data System (ADS)
Singh, Butta; Singh, Dilbag; Jaryal, A. K.; Deepak, K. K.
2012-05-01
Approximate entropy (ApEn) and sample entropy (SampEn) are the promising techniques for extracting complex characteristics of cardiovascular variability. Ectopic beats, originating from other than the normal site, are the artefacts contributing a serious limitation to heart rate variability (HRV) analysis. The approaches like deletion and interpolation are currently in use to eliminate the bias produced by ectopic beats. In this study, normal R-R interval time series of 10 healthy and 10 acute myocardial infarction (AMI) patients were analysed by inserting artificial ectopic beats. Then the effects of ectopic beats editing by deletion, degree-zero and degree-one interpolation on ApEn and SampEn have been assessed. Ectopic beats addition (even 2%) led to reduced complexity, resulting in decreased ApEn and SampEn of both healthy and AMI patient data. This reduction has been found to be dependent on level of ectopic beats. Editing of ectopic beats by interpolation degree-one method is found to be superior to other methods.
The effect of beat frequency on eye movements during free viewing.
Maróti, Emese; Knakker, Balázs; Vidnyánszky, Zoltán; Weiss, Béla
2017-02-01
External periodic stimuli entrain brain oscillations and affect perception and attention. It has been shown that background music can change oculomotor behavior and facilitate detection of visual objects occurring on the musical beat. However, whether musical beats in different tempi modulate information sampling differently during natural viewing remains to be explored. Here we addressed this question by investigating how listening to naturalistic drum grooves in two different tempi affects eye movements of participants viewing natural scenes on a computer screen. We found that the beat frequency of the drum grooves modulated the rate of eye movements: fixation durations were increased at the lower beat frequency (1.7Hz) as compared to the higher beat frequency (2.4Hz) and no music conditions. Correspondingly, estimated visual sampling frequency decreased as fixation durations increased with lower beat frequency. These results imply that slow musical beats can retard sampling of visual information during natural viewing by increasing fixation durations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bell, Wade E.; Hallworth, Richard; Wyatt, Todd A.; Sisson, Joseph H.
2015-01-01
When Paramecium encounters positive stimuli, the membrane hyperpolarizes and ciliary beat frequency increases. We adapted an established immobilization protocol using a biological adhesive and a novel digital analysis system to quantify beat frequency in immobilized Paramecium. Cells showed low mortality and demonstrated beat frequencies consistent with previous studies. Chemoattractant molecules, reduction in external potassium, and posterior stimulation all increased somatic beat frequency. In all cases, the oral groove cilia maintained a higher beat frequency than mid-body cilia, but only oral cilia from cells stimulated with chemoattactants showed an increase from basal levels. PMID:25066640
Direct Visualization of Mechanical Beats by Means of an Oscillating Smartphone
NASA Astrophysics Data System (ADS)
Giménez, Marcos H.; Salinas, Isabel; Monsoriu, Juan A.; Castro-Palacio, Juan C.
2017-10-01
The resonance phenomenon is widely known in physics courses. Qualitatively speaking, resonance takes place in a driven oscillating system whenever the frequency approaches the natural frequency, resulting in maximal oscillatory amplitude. Very closely related to resonance is the phenomenon of mechanical beating, which occurs when the driving and natural frequencies of the system are slightly different. The frequency of the beat is just the difference of the natural and driving frequencies. Beats are very familiar in acoustic systems. There are several works in this journal on visualizing the beats in acoustic systems. For instance, the microphone and the speaker of two mobile devices were used in previous work to analyze the acoustic beats produced by two signals of close frequencies. The formation of beats can also be visualized in mechanical systems, such as a mass-spring system or a double-driven string. Here, the mechanical beats in a smartphone-spring system are directly visualized in a simple way. The frequency of the beats is measured by means of the acceleration sensor of a smartphone, which hangs from a spring attached to a mechanical driver. This laboratory experiment is suitable for both high school and first-year university physics courses.
Brainstem Encoding of Aided Speech in Hearing Aid Users with Cochlear Dead Region(s)
Hassaan, Mohammad Ramadan; Ibraheem, Ola Abdallah; Galhom, Dalia Helal
2016-01-01
Introduction Neural encoding of speech begins with the analysis of the signal as a whole broken down into its sinusoidal components in the cochlea, which has to be conserved up to the higher auditory centers. Some of these components target the dead regions of the cochlea causing little or no excitation. Measuring aided speech-evoked auditory brainstem response elicited by speech stimuli with different spectral maxima can give insight into the brainstem encoding of aided speech with spectral maxima at these dead regions. Objective This research aims to study the impact of dead regions of the cochlea on speech processing at the brainstem level after a long period of hearing aid use. Methods This study comprised 30 ears without dead regions and 46 ears with dead regions at low, mid, or high frequencies. For all ears, we measured the aided speech-evoked auditory brainstem response using speech stimuli of low, mid, and high spectral maxima. Results Aided speech-evoked auditory brainstem response was producible in all subjects. Responses evoked by stimuli with spectral maxima at dead regions had longer latencies and smaller amplitudes when compared with the control group or the responses of other stimuli. Conclusion The presence of cochlear dead regions affects brainstem encoding of speech with spectral maxima perpendicular to these regions. Brainstem neuroplasticity and the extrinsic redundancy of speech can minimize the impact of dead regions in chronic hearing aid users. PMID:27413404
NASA Technical Reports Server (NTRS)
DePalma, J. L.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; Starc, V.; Rahman, M. A.; Delgado, R.
2007-01-01
We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.
Nonlinear mixing of electromagnetic waves in plasmas.
Stefan, V; Cohen, B I; Joshi, C
1989-01-27
Recently, a strong research effort has been focused on applications of beat waves in plasma interactions. This research has important implications for various aspects of plasma physics and plasma technology. This article reviews the present status of the field and comments on plasma probing, heating of magnetically confined and laser plasmas, ionospheric plasma modification, beat-wave particle acceleration, beat-wave current drive in toroidal devices, beat wave-driven free-electron lasers, and phase conjugation with beat waves.
Annotated Bibliography of USAARL Technical and Letter Reports. Volume 1. June 1963 - September 1987
1991-05-01
continuous information concerning the duration, ampli- tude and slow-phase velocity of each nystagmic beat during experiments involving the vestibular...one lead of EKG for a full work day. Mean heart rates were tabulated from the record during: Administrative work (87.2 beats per minute), automobile...driving (85.5 beats per minute), eating (90.1 beats per minute), and flying (92.0 beats per minute). Using Tukey’s multiple comparison of means
Autonomic cardiovascular responses to smoke exposure in conscious rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, T.; Hayashida, Y.
1992-05-01
Autonomic cardiovascular responses and the change in renal sympathetic nerve activity (RSNA) in response to smoke exposure were investigated in unrestrained conscious rats. Smoke exposure caused a prominent increase in RSNA (to 557.3 +/- 221.9% of the control level) and plasma norepinephrine (from 0.18 +/- 0.08 (control) to 0.66 +/- 0.22 ng/ml (at peak response of smoke exposure)), a slight increase in arterial blood pressure (from 89.6 +/- 3.3 to 103.6 +/- 3.8 mmHg), and marked bradycardia (from 386.6 +/- 12.8 to 231.3 +/- 20.6 beats/min). Respiratory rate in conscious rats was initially increased (from 1.6 +/- 0.1 to 6.1more » +/- 0.3 breaths/s) but was decreased (to 0.9 +/- 0.1 breaths/s) at the peak phase of the cardiovascular responses to smoke inhalation. Blood gases and pH reflected these changes in respiratory rate to some extent. Sinoaortic denervation did not attenuate the bradycardia (from 402 +/- 17.5 to 255.8 +/- 16.2 beats/min) or increase in RSNA (to 413.4 +/- 74.9%) that occurred during smoke inhalation. Atropine sulfate abolished the bradycardic response (from 440.4 +/- 13.8 to 485.4 +/- 8.6 beats/min). Initial tachypnea was also observed in both sinoaortic denervated rats and atropine-treated rats. Anesthesia, induced by pentobarbital sodium (30 mg/kg iv) or alpha-chloralose (65 mg/kg iv), abolished the bradycardia, the increase in RSNA, and the change in respiratory rate caused by smoke exposure. Ablation of the olfactory lobes also greatly attenuated the smoke-induced increase in RSNA (to 150.9 +/- 22.9%), bradycardia (from 372.9 +/- 19.6 to 376.3 +/- 24.1 beats/min), and the respiratory change.(ABSTRACT TRUNCATED AT 250 WORDS)« less
Palmberger, Thomas F; Augustijns, Patrick; Vetter, Anja; Bernkop-Schnürch, Andreas
2011-12-01
The aim of this study was to investigate the nasal safety of gel formulations of thiolated polymers (thiomers) by assessing their effect on ciliary beat frequency (CBF) in human nasal epithelial cells. Poly(acrylic acid) 450 kDa-cysteine (PAA-cys) and alginate-cysteine (alg-cys) were synthesized by covalent attachment of L-cysteine to the polymeric backbone. The cationic polymer chitosan-thiobutylamidine (chito-TBA) was synthesized by attaching iminothiolane to chitosan. CBF using was measured by a photometric system. CBF was measured before incubating the cells with test gels, during incubation and after washing out the polymeric test gels to evaluate reversibility of cilio-inhibition. The influence of viscosity on CBF was determined by using hydroxyethylcellulose (HEC)-gels of various concentrations. Ciliary beating was observed to be affected by viscosity, but cilia were still beating in the presence of a HEC-gel displaying an apparent viscosity of 25 Pa.s. In case of thiolated polymers and their unmodified control, a concentration-dependent decrease in CBF could be observed. PAA-cys, alg-cys, chito-TBA and their corresponding unmodified controls exhibited a moderate cilio-inhibitory effect, followed by a partial recovery of CBF when used at a concentration of 1%. Alg-cys 2% and chito-TBA 2% (m/v) gels exhibited severe cilio-inhibition, which was partially reversible. L-cysteine and reduced glutathione led to mild cilio-inhibition at concentrations of 3% (m/v). Taking into account that dilution after application and cilio-modifying effects is usually more pronounced under in vitro conditions, thiomers can be considered as suitable excipients for nasal drug delivery systems.
Pieler, D; Peinhopf, W; Becher, A C; Aurich, J E; Rose-Meierhöfer, S; Erber, R; Möstl, E; Aurich, C
2013-10-01
Establishing artificial cryptorchids by partial scrotal resection without removing the testicles is a technique for castration of bull calves that recently has gained new interest. In contrast to orchidectomy and Burdizzo castration, the stress response of calves to shortening of the scrotum is unknown. In this study, partial scrotal resection in bull calves was compared with orchidectomy, Burdizzo castration, and controls without intervention (n=10 per group, ages 56 ± 3 d). Procedures were performed under xylazine sedation and local anesthesia. We hypothesized that partial scrotal resection is least stressful. Salivary cortisol, heart rate, heart rate variability, behavior, and locomotion were analyzed. Cortisol concentration peaked 60 min after start of the procedures. Cortisol release was at least in part xylazine induced and none of the experimental procedures released additional cortisol. Heart rate increased in calves of all groups with initial handling, but immediately after xylazine sedation decreased to 30% below initial values and was not modified by surgical procedures. The heart rate variability variables standard deviation of beat-to-beat interval and root mean square of successive beat-to-beat differences increased when calves were placed on the surgery table but effects were similar in calves submitted to surgeries and control calves. Locomotion increased, whereas lying time decreased in response to all surgeries. Locomotion increase was most pronounced after orchidectomy. Plasma fibrinogen concentrations increased after orchidectomy only. With adequate pain medication, orchidectomy, Burdizzo castration, and partial scrotal resection do not differ with regard to acute stress and, by inference, pain. Partial scrotal resection when carried out under xylazine sedation and local anesthesia thus is an acceptable castration technique in bull calves. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kay, Matthew; Swift, Luther; Martell, Brian; Arutunyan, Ara; Sarvazyan, Narine
2008-05-01
We studied the origins of ectopic beats during low-flow reperfusion after acute regional ischemia in excised rat hearts. The left anterior descending coronary artery was cannulated. Perfusate was delivered to the cannula using an high-performance liquid chromatography pump. This provided not only precise control of flow rate but also avoided mechanical artifacts associated with vessel occlusion and deocclusion. Optical mapping of epicardial transmembrane potential served to identify activation wavefronts. Imaging of NADH fluorescence was used to quantify local ischemia. Our experiments suggest that low-flow reperfusion of ischemic myocardium leads to a highly heterogeneous ischemic substrate and that the degree of ischemia between adjacent patches of tissue changes in time. In contrast to transient ectopic activity observed during full-flow reperfusion, persistent ectopic arrhythmias were observed during low-flow reperfusion. The origins of ectopic beats were traceable to areas of high spatial gradients of changes in NADH fluorescence caused by low-flow reperfusion.
[Successful anesthetic management of a patient with thyroid storm using landiolol].
Fukushima, Tomihiro; Tokioka, Hiroaki; Ishii, Fumiko; Mikane, Takeshi; Oku, Satoru; Fujii, Hiromi; Katayama, Daisuke; Kawanishi, Susumu; Kosaka, Junko; Nagano, Yuri
2007-02-01
We report successful anesthetic management of a 38-year-old man with thyroid storm using an ultra-short acting beta blocker, landiolol. The patient was admitted to the hospital for severe abdominal pain. An emergency laparotomy was scheduled for perforated gastric ulcer under a condition of uncontrolled thyrotoxicosis. On arriving the operating room, he showed tachycardia of 140 beats x min(-1) and blood pressure of 140/75 mmHg and high fever of 39 degrees C with tremor, sweating and diarrhea. He was anesthetized with oxygen, nitrous oxide, sevoflurane and fentanyl. Heart rate was around 130 beats x min(-1), and the landiolol was given continuously at a rate of 0.02-0.04 microg x kg(-1) x min(-1). Heart rate was controlled bellow 120 beats x min(-1) without hypotension during anesthesia. Thiamazole and inorganic iodine were given through an enterostomy tube postoperatively, and heart rate decreased gradually. He was extubated on the third postoperative day without any sequelae.
A sensorimotor theory of temporal tracking and beat induction.
Todd, N P McAngus; Lee, C S; O'Boyle, D J
2002-02-01
In this paper, we develop a theory of the neurobiological basis of temporal tracking and beat induction as a form of sensory-guided action. We propose three principal components for the neurological architecture of temporal tracking: (1) the central auditory system, which represents the temporal information in the input signal in the form of a modulation power spectrum; (2) the musculoskeletal system, which carries out the action and (3) a controller, in the form of a parieto-cerebellar-frontal loop, which carries out the synchronisation between input and output by means of an internal model of the musculoskeletal dynamics. The theory is implemented in the form of a computational algorithm which takes sound samples as input and synchronises a simple linear mass-spring-damper system to simulate audio-motor synchronisation. The model may be applied to both the tracking of isochronous click sequences and beat induction in rhythmic music or speech, and also accounts for the approximate Weberian property of timing.
Beat Gestures Modulate Auditory Integration in Speech Perception
ERIC Educational Resources Information Center
Biau, Emmanuel; Soto-Faraco, Salvador
2013-01-01
Spontaneous beat gestures are an integral part of the paralinguistic context during face-to-face conversations. Here we investigated the time course of beat-speech integration in speech perception by measuring ERPs evoked by words pronounced with or without an accompanying beat gesture, while participants watched a spoken discourse. Words…
NASA Technical Reports Server (NTRS)
Triedman, J. K.; Perrott, M. H.; Cohen, R. J.; Saul, J. P.
1995-01-01
Fourier-based techniques are mathematically noncausal and are therefore limited in their application to feedback-containing systems, such as the cardiovascular system. In this study, a mathematically causal time domain technique, autoregressive moving average (ARMA) analysis, was used to parameterize the relations of respiration and arterial blood pressure to heart rate in eight humans before and during total cardiac autonomic blockade. Impulse-response curves thus generated showed the relation of respiration to heart rate to be characterized by an immediate increase in heart rate of 9.1 +/- 1.8 beats.min-1.l-1, followed by a transient mild decrease in heart rate to -1.2 +/- 0.5 beats.min-1.l-1 below baseline. The relation of blood pressure to heart rate was characterized by a slower decrease in heart rate of -0.5 +/- 0.1 beats.min-1.mmHg-1, followed by a gradual return to baseline. Both of these relations nearly disappeared after autonomic blockade, indicating autonomic mediation. Maximum values obtained from the respiration to heart rate impulse responses were also well correlated with frequency domain measures of high-frequency "vagal" heart rate control (r = 0.88). ARMA analysis may be useful as a time domain representation of autonomic heart rate control for cardiovascular modeling.
Neural Entrainment to Polyrhythms: A Comparison of Musicians and Non-musicians.
Stupacher, Jan; Wood, Guilherme; Witte, Matthias
2017-01-01
Music can be thought of as a dynamic path over time. In most cases, the rhythmic structure of this path, such as specific sequences of strong and weak beats or recurring patterns, allows us to predict what and particularly when sounds are going to happen. Without this ability we would not be able to entrain body movements to music, like we do when we dance. By combining EEG and behavioral measures, the current study provides evidence illustrating the importance of ongoing neural oscillations at beat-related frequencies-i.e., neural entrainment-for tracking and predicting musical rhythms. Participants (13 musicians and 13 non-musicians) listened to drum rhythms that switched from a quadruple rhythm to a 3-over-4 polyrhythm. After a silent period of ~2-3 s, participants had to decide whether a target stimulus was presented on time with the triple beat of the polyrhythm, too early, or too late. Results showed that neural oscillations reflected the rhythmic structure of both the simple quadruple rhythm and the more complex polyrhythm with no differences between musicians and non-musicians. During silent periods, the observation of time-frequency plots and more commonly used frequency spectra analyses suggest that beat-related neural oscillations were more pronounced in musicians compared to non-musicians. Neural oscillations during silent periods are not driven by an external input and therefore are thought to reflect top-down controlled endogenous neural entrainment. The functional relevance of endogenous neural entrainment was demonstrated by a positive correlation between the amplitude of task-relevant neural oscillations during silent periods and the number of correctly identified target stimuli. In sum, our findings add to the evidence supporting the neural resonance theory of pulse and meter. Furthermore, they indicate that beat-related top-down controlled neural oscillations can exist without external stimulation and suggest that those endogenous oscillations are strengthened by musical expertise. Finally, this study shows that the analysis of neural oscillations can be a useful tool to assess how we perceive and process complex auditory stimuli such as polyrhythms.
Bagherpoor, H M; Salmasi, Farzad R
2015-07-01
In this paper, robust model reference adaptive tracking controllers are considered for Single-Input Single-Output (SISO) and Multi-Input Multi-Output (MIMO) linear systems containing modeling uncertainties, unknown additive disturbances and actuator fault. Two new lemmas are proposed for both SISO and MIMO, under which dead-zone modification rule is improved such that the tracking error for any reference signal tends to zero in such systems. In the conventional approach, adaption of the controller parameters is ceased inside the dead-zone region which results tracking error, while preserving the system stability. In the proposed scheme, control signal is reinforced with an additive term based on tracking error inside the dead-zone which results in full reference tracking. In addition, no Fault Detection and Diagnosis (FDD) unit is needed in the proposed approach. Closed loop system stability and zero tracking error are proved by considering a suitable Lyapunov functions candidate. It is shown that the proposed control approach can assure that all the signals of the close loop system are bounded in faulty conditions. Finally, validity and performance of the new schemes have been illustrated through numerical simulations of SISO and MIMO systems in the presence of actuator faults, modeling uncertainty and output disturbance. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Sng, B L; Tan, H S; Sia, A T H
2014-01-01
Hypotension necessitating vasopressor administration occurs commonly during caesarean section under spinal anaesthesia. We developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non-invasive arterial pressure monitoring. A phenylephrine bolus of 50 μg was given at 30-s intervals when systolic blood pressure fell < 90% of baseline; an ephedrine bolus of 4 mg was given instead if systolic pressure fell < 90% of baseline together with a heart rate < 60 beats.min(-1). The control group used manual boluses of either phenylephrine 100 μg or ephedrine 8 mg, administered at 1-min intervals based on the same thresholds for systolic pressure and heart rate. This randomised, controlled, double-blinded trial involved 213 healthy women who underwent elective caesarean delivery under spinal anaesthesia using 11 mg hyperbaric bupivacaine with 15 μg fentanyl and 100 μg morphine. The automated vasopressor group had better systolic pressure control, with 37/106 (34.9%) having any beat-to-beat systolic pressure reading < 80% of baseline compared with 63/107 (58.9%) in the control group (p < 0.001). There was no difference in the incidence of reactive hypertension, defined as systolic pressure > 120% of baseline, with 8/106 (7.5%) in the automated vasopressor group vs 14/107 (13.1%) in the control group, or total dose of vasopressors. The automated vasopressor group had lower median absolute performance error of 8.5% vs control of 9.8% (p = 0.013), and reduced incidence of nausea (1/106 (0.9%) vs 11/107 (10.3%), p = 0.005). Neonatal umbilical cord pH, umbilical lactate and Apgar scores were similar. Hence, our system afforded better control of maternal blood pressure and reduced nausea with no increase in reactive hypertension when compared with manual boluses. © 2013 The Association of Anaesthetists of Great Britain and Ireland.
Grose, John H.; Buss, Emily; Hall, Joseph W.
2012-01-01
Previous studies of binaural beats have noted individual variability and response lability, but little attention has been paid to the salience of the binaural beat percept. The purpose of this study was to gauge the strength of the binaural beat percept by matching its salience to that of sinusoidal amplitude modulation (SAM), and to then compare rate discrimination for the two types of fluctuation. Rate discrimination was measured for standard rates of 4, 8, 16, and 32 Hz – all in the 500-Hz carrier region. Twelve normal-hearing adults participated in this study. The results indicated that discrimination acuity for binaural beats is similar to that for SAM tones whose depths of modulation have been adjusted to provide equivalent modulation salience. The matched-salience SAM tones had relatively shallow depths of modulation, suggesting that the perceptual strength of binaural beats is relatively weak, although all listeners perceived them. The Weber fraction for detection of an increase in binaural beat rate is roughly constant across beat rates, at least for rates above 4 Hz, as is rate discrimination for SAM tones. PMID:22326292
Grose, John H; Buss, Emily; Hall, Joseph W
2012-03-01
Previous studies of binaural beats have noted individual variability and response lability, but little attention has been paid to the salience of the binaural beat percept. The purpose of this study was to gauge the strength of the binaural beat percept by matching its salience to that of sinusoidal amplitude modulation (SAM), and to then compare rate discrimination for the two types of fluctuation. Rate discrimination was measured for standard rates of 4, 8, 16, and 32 Hz - all in the 500-Hz carrier region. Twelve normal-hearing adults participated in this study. The results indicated that discrimination acuity for binaural beats is similar to that for SAM tones whose depths of modulation have been adjusted to provide equivalent modulation salience. The matched-salience SAM tones had relatively shallow depths of modulation, suggesting that the perceptual strength of binaural beats is relatively weak, although all listeners perceived them. The Weber fraction for detection of an increase in binaural beat rate is roughly constant across beat rates, at least for rates above 4 Hz, as is rate discrimination for SAM tones. Copyright © 2012 Elsevier B.V. All rights reserved.
Nozaradan, Sylvie; Zerouali, Younes; Peretz, Isabelle; Mouraux, André
2015-03-01
Synchronizing movements with rhythmic inputs requires tight coupling of sensory and motor neural processes. Here, using a novel approach based on the recording of steady-state-evoked potentials (SS-EPs), we examine how distant brain areas supporting these processes coordinate their dynamics. The electroencephalogram was recorded while subjects listened to a 2.4-Hz auditory beat and tapped their hand on every second beat. When subjects tapped to the beat, the EEG was characterized by a 2.4-Hz SS-EP compatible with beat-related entrainment and a 1.2-Hz SS-EP compatible with movement-related entrainment, based on the results of source analysis. Most importantly, when compared with passive listening of the beat, we found evidence suggesting an interaction between sensory- and motor-related activities when subjects tapped to the beat, in the form of (1) additional SS-EP appearing at 3.6 Hz, compatible with a nonlinear product of sensorimotor integration; (2) phase coupling of beat- and movement-related activities; and (3) selective enhancement of beat-related activities over the hemisphere contralateral to the tapping, suggesting a top-down effect of movement-related activities on auditory beat processing. Taken together, our results are compatible with the view that rhythmic sensorimotor synchronization is supported by a dynamic coupling of sensory and motor related activities. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Normand, Hervé; Lemarchand, Erick; Arbeille, Philippe; Quarck, Gaëlle; Vaïda, Pierre; Duretete, Arnaud; Denise, Pierre
2007-12-01
Accurate measurement of beat-to-beat arterial blood pressure is essential for understanding the cardiovascular adaptation to weightlessness; however, the intra-arterial standard of beat-to-beat blood pressure measurement has never been used during space flight because of its invasive nature. The aim of the present study was to compare noninvasive radial artery tonometry blood pressure measurement with intra-radial pressure measurement during microgravity and hypergravity generated by parabolic flights. Two study participants, equipped with an intra-radial pressure line on the left arm and a Colin CBM-7000 (Colin Corp., Komaki City, Japan) beat-to-beat pressure measurement apparatus on the right arm, were studied in a supine position, during parabolic flights on board of the Airbus A300 OG of the Centre National d'Etudes Spatiales. The mean and standard deviations of the beat-to-beat difference between tonometric and intra-radial blood pressure were calculated for systolic and diastolic arterial pressure in the three gravity conditions (1g, 0 g and 1.8 g) experienced during parabolic flight. The Colin CBM-7000 met the specifications required by the Association for the Advancement of Medical Instrumentation in the 0 g environment. Gravity, however, significantly affected the difference between tonometric and intra-arterial blood pressure, possibly owing to the effect of gravity on the apparent weight of the device and the corresponding calibration factor. We conclude that the Colin CBM-7000 can be used with confidence during space flight.
Enhanced timing abilities in percussionists generalize to rhythms without a musical beat.
Cameron, Daniel J; Grahn, Jessica A
2014-01-01
The ability to entrain movements to music is arguably universal, but it is unclear how specialized training may influence this. Previous research suggests that percussionists have superior temporal precision in perception and production tasks. Such superiority may be limited to temporal sequences that resemble real music or, alternatively, may generalize to musically implausible sequences. To test this, percussionists and nonpercussionists completed two tasks that used rhythmic sequences varying in musical plausibility. In the beat tapping task, participants tapped with the beat of a rhythmic sequence over 3 stages: finding the beat (as an initial sequence played), continuation of the beat (as a second sequence was introduced and played simultaneously), and switching to a second beat (the initial sequence finished, leaving only the second). The meters of the two sequences were either congruent or incongruent, as were their tempi (minimum inter-onset intervals). In the rhythm reproduction task, participants reproduced rhythms of four types, ranging from high to low musical plausibility: Metric simple rhythms induced a strong sense of the beat, metric complex rhythms induced a weaker sense of the beat, nonmetric rhythms had no beat, and jittered nonmetric rhythms also had no beat as well as low temporal predictability. For both tasks, percussionists performed more accurately than nonpercussionists. In addition, both groups were better with musically plausible than implausible conditions. Overall, the percussionists' superior abilities to entrain to, and reproduce, rhythms generalized to musically implausible sequences.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
1985-12-31
puretone threshold at ultra-audiometric frequencies (10,000-20,000 Hz; e) Masking Level Differences (MLD) used to assess binaural processing in the auditory...SD in 5 Supine Resting Subjects) I Pre-exposure Mean Exposure Time Control 2.6 Hours 9.8 Hours I Heart Rate 59.8 + 10.7 50.2 + 8.5 63.6* + 14.4 ( beats ...complete absence of ectopic beats by 6 hours post-exposure. 72 FIGURE 26. 1 HEART RATE RESPONSES TO RISING FROM SUPINE TO STANDING POSITION IN SUBJECT (C.H
Responses of dead forest fuel moisture to climate change
Yongqiang Liu
2016-01-01
Forest fuel moisture is an important factor for wildland fire behavior. Predicting future wildfire trends and controlled burned conditions is essential to effective natural resource management, but the associated effects of forest fuel moisture remain uncertain. This study investigates the responses of dead forest fuel moisture to climate change in the...
Effects on birds of fenthion aerial application for mosquito control
DeWeese, L.R.; McEwen, L.C.; Settimi, L.A.; Deblinger, R.D.
1983-01-01
Effects on birds of an aerial application of fenthion, a potent organophosphorus cholinesterase (ChE)-inhibiting insecticide, were assessed on four study sites 1.8 to 3.6 km2 in size. These sites were located within 121.5 km2 of wet meadows treated with 47 g of fenthion (AI) per ha in ultralow- volume formulation. Assessment methods were searches for sick or dead birds, measurements of brain ChE activity in specimens found dead or collected alive at different time intervals, and counts of bird populations. After treatment, 99 birds and 15 mammals were found sick or dead; 106 of these were on one site. Brain ChE activity in dead birds was depressed sufficiently to indicate that death was caused by an anti-ChE substance. Brain ChE activity in three common bird species collected alive showed the greatest reduction 2 days postspray. Two of these species had ChE activity that was still significantly (P<0.05) depressed 15 days postspray. Bird populations declined most where mortality was heaviest. Fenthion sprayed for mosquito control was life threatening to many birds inhabiting treated meadows.
Uptake of dietary PCB by pregnant big brown bats (Eptesicus fuscus) and their fetuses
Clark, D.R.
1978-01-01
In a previous study (CLARK and LAMONT 1976), 26 pregnant big brown bats were captured, caged, and fed uncontaminated mealworms until their litters were born. Immediately after parturition, female bats and litters were frozen. Five litters included at least one dead young, and these five litters contained significantly more of the PCB, Aroclor 1260, than did the 21 litters with only living young....The present study attempted to verify that Aroclor 1260 could cause stillbirths. I fed 18 of 36 pregnant big brown bats mealworms containing 6.36 ppm of Aroclor 1260 prior to birth of their litters. Both carcasses and litters of dosed females contained approximately 10 times more PCB than their respective controls, but no additional stillbirths resulted. Three of 18 control litters included dead young, whereas the comparable ratio among litters from dosed females was one of 18. Additional comparisons involving means of litter weight, adult female weight, parturition date, days in captivity, tooth wear, and percentage fat also failed to show any effect of the PCB....The association found earlier between PCB and dead young (CLARK and LAMONT 1976) was not one of cause and effect. In both studies, bats that had not been dosed showed greater PCB residues among younger females. Among control bats in the present series, females that produced dead young were significantly younger (that is, showed significantly less tooth wear) than other females. In sum, whereas dead young seemed to have been caused by greater residues, these two factors were actually independent of each other but associated with a third factor--age of the female parent bat.
Kennel, Susan; Taylor, Ann Gill; Lyon, Debra; Bourguignon, Cheryl
2010-02-01
The purpose of this pilot study was to explore the potential for the use of binaural auditory beat stimulation to reduce the symptom of inattention in children and adolescents with attention-deficit/hyperactivity disorder. This pilot study had a randomized, double-blind, placebo-controlled design. Twenty participants were randomly assigned to listen to either an audio program on compact disk that contained binaural auditory beats or a sham audio program that did not have binaural beats for 20 minutes, three times a week for 3 weeks. The Children's Color Trails Test, the Color Trails Test, the Test of Variables of Attention (TOVA), and the Homework Problem Checklist were used to measure changes in inattention pre- and postintervention. Repeated measures analysis of variance was used to analyze pre- and postintervention scores on the Color Trails Tests, Homework Problem Checklist, and the TOVA. The effect of time was significant on the Color Trails Test. However, there were no significant group differences on the Color Trails Test or the TOVA scores postintervention. Parents reported that the study participants had fewer homework problems postintervention. The results from this study indicate that binaural auditory beat stimulation did not significantly reduce the symptom of inattention in the experimental group. However, parents and adolescents stated that homework problems due to inattention improved during the 3-week study. Parents and participants stated that the modality was easy to use and helpful. Therefore, this modality should be studied over a longer time frame in a larger sample to further its effectiveness to reduce the symptom of inattention in those diagnosed with attention-deficit/hyperactivity disorder. Copyright 2010 Elsevier Inc. All rights reserved.
Haensch, Carl-Albrecht; Jörg, Johannes
2006-04-01
Extrasystoles occur in normal subjects but are significant more frequently (16.25% vs. 55%; chi(2) = 19.3; P < 0.001) seen in Parkinson's disease (PD) patients. The extrasystolic decreases in stroke volume and systolic pressure activate sympathetic vasomotor innervation and lead to a blood pressure increase for a few heartbeats. The purpose of this study was to prove whether the short time analysis of this blood pressure regulation allows the assessment of sympathetic neurocirculatory function. Records of noninvasive blood pressure monitoring were reviewed from 40 PD patients and 80 controls. A battery of cardiovascular autonomic tests, including Valsalva maneuver, tilt-table testing, echocardiography, and cardiac scintigraphy with [(123)I]meta-iodobenzylguanidine were performed. Fifty-five percent of the PD patients had at least one premature ventricular contraction (PVC) in 10 minutes lying supine at rest. After every PVC (13 PVCs) recorded from normal subjects, we found an increase in systolic blood pressure above base line with a maximum at the seventh heart beat. In all of the 22 PD patients, the systolic blood pressure was significantly decreased less than baseline in every PVC from the second to the ninth postextrasystolic beat (P < 0.001). In both groups, the extrasystolic fall in blood pressure was on average approximately 22%. The postextrasystolic potentiation did not differ (5.3% vs. 4.4%, not significant). If a PVC occurs, the analysis of short-time blood pressure regulation is a sensitive tool for baroreceptor reflex function. The advantage of this method results from the independence of patients cooperation and the high sensitivity to prove a sympathetic neurocirculatory failure within 10 heart beats. Copyright 2005 Movement Disorder Society.
Effect of Propellant Feed System Coupling and Hydraulic Parameters on Analysis of Chugging
NASA Technical Reports Server (NTRS)
Wood, Don J.; Dorsch, Robert G.
1967-01-01
A digital distributed parameter model was used to study the effects of propellant-feed- system coupling and various hydraulic parameters on the analytical prediction of chugging instabilities. Coupling between the combustion chamber and feed system was controlled by varying the compliance of the injector-dome region. The coupling with the feed system above the pump was varied by changing the amount of cavitation compliance at the pump inlet. The stability limits and chugging frequencies proved to be strongly dependent on the degree of feed-system coupling. The maximum stability condition occurred with intermediate coupling. Under conditions of a high degree of feed-system-combustor coupling, the stability limits and chugging frequencies were primarily dependent on the feed-system characteristics; the responses were characterized by beating patterns. For the system analyzed, the pump suction line had little effect on the stability limits or chugging frequencies. Beating, present under the condition of near zero injector -dome compliance, was eliminated when the suction line was decoupled by employing a sufficiently high value of pump-inlet compliance. Under conditions of maximum feed-system coupling, the magnitude and distribution of line losses in the discharge line had a significant effect on the stability limits but had negligible effect on the chugging frequency and beating characteristics. Also, the length of the discharge line greatly affected the stability limits, chugging frequency, and beating characteristics. The length of the suction line, however, had little effect on the stability limits and chugging frequency but did influence the beating pattern. A resistive-shunt device attached to the pump discharge line to suppress chugging was investigated. The analysis showed that the device was effective under conditions of high feed-system coupling.
1981-03-01
adjusting the metronome beats to coincide with the stressed syllables. The sentences were constructed to have a regular rhythm. They were: "I think’ that it...rate was 92 beats per minute, the conversational rate was 120 beats per minute, and the fast rate was 160 beats per minute. Both sentences were recorded...shown in Figure 6 also suggests amplitude modulation (von Holst’s superimposition effect). Thus on some coinciding cycles a " beat " phenomenon can be
Bell, Wade E; Hallworth, Richard; Wyatt, Todd A; Sisson, Joseph H
2015-01-01
When Paramecium encounters positive stimuli, the membrane hyperpolarizes and ciliary beat frequency increases. We adapted an established immobilization protocol using a biological adhesive and a novel digital analysis system to quantify beat frequency in immobilized Paramecium. Cells showed low mortality and demonstrated beat frequencies consistent with previous studies. Chemoattractant molecules, reduction in external potassium, and posterior stimulation all increased somatic beat frequency. In all cases, the oral groove cilia maintained a higher beat frequency than mid-body cilia, but only oral cilia from cells stimulated with chemoattactants showed an increase from basal levels. © 2014 The Author(s) Journal of Eukaryotic Microbiology © 2014 International Society of Protistologists.
Beat to beat variability in cardiovascular variables: noise or music?
NASA Technical Reports Server (NTRS)
Appel, M. L.; Berger, R. D.; Saul, J. P.; Smith, J. M.; Cohen, R. J.
1989-01-01
Cardiovascular variables such as heart rate, arterial blood pressure, stroke volume and the shape of electrocardiographic complexes all fluctuate on a beat to beat basis. These fluctuations have traditionally been ignored or, at best, treated as noise to be averaged out. The variability in cardiovascular signals reflects the homeodynamic interplay between perturbations to cardiovascular function and the dynamic response of the cardiovascular regulatory systems. Modern signal processing techniques provide a means of analyzing beat to beat fluctuations in cardiovascular signals, so as to permit a quantitative, noninvasive or minimally invasive method of assessing closed loop hemodynamic regulation and cardiac electrical stability. This method promises to provide a new approach to the clinical diagnosis and management of alterations in cardiovascular regulation and stability.
Model for the heart beat-to-beat time series during meditation
NASA Astrophysics Data System (ADS)
Capurro, A.; Diambra, L.; Malta, C. P.
2003-09-01
We present a model for the respiratory modulation of the heart beat-to-beat interval series. The model consists of a pacemaker, that simulates the membrane potential of the sinoatrial node, modulated by a periodic input signal plus correlated noise that simulates the respiratory input. The model was used to assess the waveshape of the respiratory signals needed to reproduce in the phase space the trajectory of experimental heart beat-to-beat interval data. The data sets were recorded during meditation practices of the Chi and Kundalini Yoga techniques. Our study indicates that in the first case the respiratory signal has the shape of a smoothed square wave, and in the second case it has the shape of a smoothed triangular wave.
Pacemakers and Implantable Defibrillators: MedlinePlus Health Topic
... pattern. Most arrhythmias result from problems in the electrical system of the heart. If your arrhythmia is ... pacemaker helps control abnormal heart rhythms. It uses electrical pulses to prompt the heart to beat at ...
Effects of acute hyperthermia on the carotid baroreflex control of heart rate in humans
NASA Astrophysics Data System (ADS)
Yamazaki, F.; Sagawa, S.; Torii, R.; Endo, Y.; Shiraki, K.
The purpose of this study was to examine the effect of hyperthermia on the carotid baroreceptor-cardiac reflexes in humans. Nine healthy males underwent acute hyperthermia (esophageal temperature 38.0° C) produced by hot water-perfused suits. Beat-to-beat heart rate (HR) responses were determined during positive and negative R-wave-triggered neck pressure steps from +40 to -65 mm Hg during normothermia and hyperthermia. The carotid baroreceptor-cardiac reflex sensitivity was evaluated from the maximum slope of the HR response to changes in carotid distending pressure. Buffering capacity of the HR response to carotid distending pressure was evaluated in % from a reference point calculated as (HR at 0 mm Hg neck pressure-minimum HR)/HR range ×100. An upward shift of the curve was evident in hyperthermia because HR increased from 57.7+/-2.4 beats/min in normothermia to 88.7+/-4.1 beats/min in hyperthermia (P<0.05) without changes in mean arterial pressure. The maximum slope of the curve in hyperthermia was similar to that in normothermia. The reference point was increased (P<0.05) during hyperthermia. These results suggest that the sensitivity of the carotid baroreflex of HR remains unchanged in hyperthermia. However, the capacity for tachycardia response to rapid onset of hypotension is reduced and the capacity for bradycardia response to sudden hypertension is increased during acute hyperthermia.
Jones, Jenny; Thomson, Patricia; Lauder, William; Howie, Kate; Leslie, Stephen J
2012-11-01
Reflexologists claim that massage to specific points of the feet increases blood supply to internal organs. This study measured changes in cardiovascular parameters in subjects receiving reflexology to areas of their feet thought to correspond to the heart (intervention) compared with other areas which are not (control). 16 reflexology-naive healthy volunteers received an active and control reflexology treatment in an RCT, double-blind repeated measures study. 'Beat-to-beat' continuous measurement of selected cardiovascular parameters, State Anxiety Inventory. Cardiac index decreased significantly in the intervention group during left foot treatment (LFT) (baseline mean 2.6; standard deviation (SD) 0.75; 95% CI ± 0.38 vs. LFT mean 2.45; SD 0.68; CI 0.35), effect size (p = 0.035, omega squared effect (w2) = 0.002; w = 0.045). Reflexology massage applied to the upper part of the left foot may have a modest specific effect on the cardiac index of healthy volunteers. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Mukkamala, R.; Mathias, J. M.; Mullen, T. J.; Cohen, R. J.; Freeman, R.
1999-01-01
We applied cardiovascular system identification (CSI) to characterize closed-loop cardiovascular regulation in patients with diabetic autonomic neuropathy (DAN). The CSI method quantitatively analyzes beat-to-beat fluctuations in noninvasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV) to characterize four physiological coupling mechanisms, two of which are autonomically mediated (the heart rate baroreflex and the coupling of respiration, measured in terms of ILV, to heart rate) and two of which are mechanically mediated (the coupling of ventricular contraction to the generation of the ABP wavelet and the coupling of respiration to ABP). We studied 37 control and 60 diabetic subjects who were classified as having minimal, moderate, or severe DAN on the basis of standard autonomic tests. The autonomically mediated couplings progressively decreased with increasing severity of DAN, whereas the mechanically mediated couplings were essentially unchanged. CSI identified differences between the minimal DAN and control groups, which were indistinguishable based on the standard autonomic tests. CSI may provide a powerful tool for assessing DAN.
Spatiotemporal control to eliminate cardiac alternans using isostable reduction
NASA Astrophysics Data System (ADS)
Wilson, Dan; Moehlis, Jeff
2017-03-01
Cardiac alternans, an arrhythmia characterized by a beat-to-beat alternation of cardiac action potential durations, is widely believed to facilitate the transition from normal cardiac function to ventricular fibrillation and sudden cardiac death. Alternans arises due to an instability of a healthy period-1 rhythm, and most dynamical control strategies either require extensive knowledge of the cardiac system, making experimental validation difficult, or are model independent and sacrifice important information about the specific system under study. Isostable reduction provides an alternative approach, in which the response of a system to external perturbations can be used to reduce the complexity of a cardiac system, making it easier to work with from an analytical perspective while retaining many of its important features. Here, we use isostable reduction strategies to reduce the complexity of partial differential equation models of cardiac systems in order to develop energy optimal strategies for the elimination of alternans. Resulting control strategies require significantly less energy to terminate alternans than comparable strategies and do not require continuous state feedback.
Selective neuronal entrainment to the beat and meter embedded in a musical rhythm.
Nozaradan, Sylvie; Peretz, Isabelle; Mouraux, André
2012-12-05
Fundamental to the experience of music, beat and meter perception refers to the perception of periodicities while listening to music occurring within the frequency range of musical tempo. Here, we explored the spontaneous building of beat and meter hypothesized to emerge from the selective entrainment of neuronal populations at beat and meter frequencies. The electroencephalogram (EEG) was recorded while human participants listened to rhythms consisting of short sounds alternating with silences to induce a spontaneous perception of beat and meter. We found that the rhythmic stimuli elicited multiple steady state-evoked potentials (SS-EPs) observed in the EEG spectrum at frequencies corresponding to the rhythmic pattern envelope. Most importantly, the amplitude of the SS-EPs obtained at beat and meter frequencies were selectively enhanced even though the acoustic energy was not necessarily predominant at these frequencies. Furthermore, accelerating the tempo of the rhythmic stimuli so as to move away from the range of frequencies at which beats are usually perceived impaired the selective enhancement of SS-EPs at these frequencies. The observation that beat- and meter-related SS-EPs are selectively enhanced at frequencies compatible with beat and meter perception indicates that these responses do not merely reflect the physical structure of the sound envelope but, instead, reflect the spontaneous emergence of an internal representation of beat, possibly through a mechanism of selective neuronal entrainment within a resonance frequency range. Taken together, these results suggest that musical rhythms constitute a unique context to gain insight on general mechanisms of entrainment, from the neuronal level to individual level.
Patel, Aniruddh D.; Iversen, John R.
2013-01-01
Every human culture has some form of music with a beat: a perceived periodic pulse that structures the perception of musical rhythm and which serves as a framework for synchronized movement to music. What are the neural mechanisms of musical beat perception, and how did they evolve? One view, which dates back to Darwin and implicitly informs some current models of beat perception, is that the relevant neural mechanisms are relatively general and are widespread among animal species. On the basis of recent neural and cross-species data on musical beat processing, this paper argues for a different view. Here we argue that beat perception is a complex brain function involving temporally-precise communication between auditory regions and motor planning regions of the cortex (even in the absence of overt movement). More specifically, we propose that simulation of periodic movement in motor planning regions provides a neural signal that helps the auditory system predict the timing of upcoming beats. This “action simulation for auditory prediction” (ASAP) hypothesis leads to testable predictions. We further suggest that ASAP relies on dorsal auditory pathway connections between auditory regions and motor planning regions via the parietal cortex, and suggest that these connections may be stronger in humans than in non-human primates due to the evolution of vocal learning in our lineage. This suggestion motivates cross-species research to determine which species are capable of human-like beat perception, i.e., beat perception that involves accurate temporal prediction of beat times across a fairly broad range of tempi. PMID:24860439
ERIC Educational Resources Information Center
Song, Shi
2018-01-01
This research aims at analyzing the correlation between parents' awareness of anti-domestic violence in China, attitude and frequency of beating children. According to the literature analysis, this paper sets children's parents' anti-domestic violence cognition and attitude of beating children as independent variable, and the frequency of beating…
Effects of single cycle binaural beat duration on auditory evoked potentials.
Mihajloski, Todor; Bohorquez, Jorge; Özdamar, Özcan
2014-01-01
Binaural beat (BB) illusions are experienced as continuous central pulsations when two sounds with slightly different frequencies are delivered to each ear. It has been shown that steady-state auditory evoked potentials (AEPs) to BBs can be captured and investigated. The authors recently developed a new method of evoking transient AEPs to binaural beats using frequency modulated stimuli. This methodology was able to create single BBs in predetermined intervals with varying carrier frequencies. This study examines the effects of the BB duration and the frequency modulating component of the stimulus on the binaural beats and their evoked potentials. Normal hearing subjects were tested with a set of four durations (25, 50, 100, and 200 ms) with two stimulation configurations, binaural dichotic (binaural beats) and diotic (frequency modulation). The results obtained from the study showed that out of the given durations, the 100 ms beat, was capable of evoking the largest amplitude responses. The frequency modulation effect showed a decrease in peak amplitudes with increasing beat duration until their complete disappearance at 200 ms. Even though, at 200 ms, the frequency modulation effects were not present, the binaural beats were still perceived and captured as evoked potentials.
Neurocardiology: Structure-Based Function.
Ardell, Jeffrey L; Armour, John Andrew
2016-09-15
Cardiac control is mediated via a series of reflex control networks involving somata in the (i) intrinsic cardiac ganglia (heart), (ii) intrathoracic extracardiac ganglia (stellate, middle cervical), (iii) superior cervical ganglia, (iv) spinal cord, (v) brainstem, and (vi) higher centers. Each of these processing centers contains afferent, efferent, and local circuit neurons, which interact locally and in an interdependent fashion with the other levels to coordinate regional cardiac electrical and mechanical indices on a beat-to-beat basis. This control system is optimized to respond to normal physiological stressors (standing, exercise, and temperature); however, it can be catastrophically disrupted by pathological events such as myocardial ischemia. In fact, it is now recognized that autonomic dysregulation is central to the evolution of heart failure and arrhythmias. Autonomic regulation therapy is an emerging modality in the management of acute and chronic cardiac pathologies. Neuromodulation-based approaches that target select nexus points of this hierarchy for cardiac control offer unique opportunities to positively affect therapeutic outcomes via improved efficacy of cardiovascular reflex control. As such, understanding the anatomical and physiological basis for such control is necessary to implement effectively novel neuromodulation therapies. © 2016 American Physiological Society. Compr Physiol 6:1635-1653, 2016. Copyright © 2016 John Wiley & Sons, Inc.
Cell death induced by Morarah and Khaltita in hepatoma cancer cells (Huh-7).
Baig, Saeeda; Alamgir, Mohiuddin
2009-10-01
To compare the combined and isolated growth inhibitory effects of Morarah and Khaltita (herbs) on hepatoma cell lines (Huh-7), through induction of apoptosis or necrosis. Comparative controlled in-vitro study. The Molecular Biology Laboratory, The Aga Khan University, Karachi, from June to December 2006. The growth of hepatoma cell lines (Huh-7) was checked by adding Khaltita and Morarah to the cells before culture in a 24 well plate. Six wells were selected and labeled for each of the four variables (controls, Khaltita, Morarah and mixture). After 2 days, cells were studied under an inverted phase contrast microscope and fields were recorded. Approximately four fields per slide of higher intensity were selected randomly to determine the dead cell density, and the procedure was repeated 10 or more times. Frequency and percentages were calculated for dead or alive cells in controls, Morarah, Khaltita and their mixture. Chi-square was used to compare the qualitative variables. P-values < 0.05 were considered significant. Morarah and Khaltita were found to induce statistically significant (p < 0.001) cell death in hepatoma cell lines (Huh-7). At a magnification of 40x, the controls showed 1% dead cells compared to 91% in Morarah, 83% in Khaltita and 73% in combined mixture of Khaltita and Morarah. At magnification of 20x, the controls showed 4% dead cells compared to 44% in Morarah, 47% in Khaltita and 49% in the combined mixture of Khaltita and Morarah. Morarah and Khaltita induced cell death in cultured hepatoma cells (Huh-7).
Corkidi, G; Montoya, F; Hernández-Herrera, P; Ríos-Herrera, W A; Müller, M F; Treviño, C L; Darszon, A
2017-09-01
Are there intracellular Ca2+ ([Ca2+]i) oscillations correlated with flagellar beating in human sperm? The results reveal statistically significant [Ca2+]i oscillations that are correlated with the human sperm flagellar beating frequency, when measured in three-dimensions (3D). Fast [Ca2+]i oscillations that are correlated to the beating flagellar frequency of cells swimming in a restricted volume have been detected in hamster sperm. To date, such findings have not been confirmed in any other mammalian sperm species. An important question that has remained regarding these observations is whether the fast [Ca2+]i oscillations are real or might they be due to remaining defocusing effects of the Z component arising from the 3D beating of the flagella. Healthy donors whose semen samples fulfill the WHO criteria between the age of 18-28 were selected. Cells from at least six different donors were utilized for analysis. Approximately the same number of experimental and control cells were analyzed. Motile cells were obtained by the swim-up technique and were loaded with Fluo-4 (Ca2+ sensitive dye) or with Calcein (Ca2+ insensitive dye). Ni2+ was used as a non-specific plasma membrane Ca2+ channel blocker. Fluorescence data and flagella position were acquired in 3D. Each cell was recorded for up to 5.6 s within a depth of 16 microns with a high speed camera (coupled to an image intensifier) acquiring at a rate of 3000 frames per second, while an oscillating objective vibrated at 90 Hz via a piezoelectric device. From these samples, eight experimental and nine control sperm cells were analyzed in both 2D and 3D. We have implemented a new system that allows [Ca2+]i measurements of the human sperm flagellum beating in 3D. These measurements reveal statistically significant [Ca2+]i oscillations that correlate with the flagellar beating frequency. These oscillations may arise from intracellular sources and/or Ca2+ transporters, as they were insensitive to external Ni2+, a non-specific plasma membrane Ca2+ channel blocker. N/A. Analysis in 3D needs a very fast image acquisition rate to correctly sample a volume containing swimming sperm. This condition requires a very short exposure time per image making it necessary to use an image intensifier which also increases noise. The lengthy analysis time required to obtain reliable results limited the number of cells that could be analyzed. The possibility of recording flagellar [Ca2+]i oscillations described here may open a new avenue to better understand ciliary and flagellar beating that are fundamental for mucociliary clearance, oocyte transport, fertilization, cerebrospinal fluid pressure regulation and developmental left-right symmetry breaking in the embryonic node. This work was supported by Consejo Nacional de Ciencia y Tecnología (CONACyT) (grants 253952 to G.C.; 156667 to F.M.M. and Fronteras 71 39908-Q to A.D. and Post-doctoral scholarships 366844 to P.H.-H. and 291028 to F.M.) and the Dirección General de Asuntos del Personal Académico of the Universidad Nacional Autónoma de México (DGAPA-UNAM) (grants CJIC/CTIC/4898/2016 to F.M. and IN205516 to A.D.). There are no conflicts of interest to declare. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com
2017-10-01
discovered that one of the controls, who is morbidly obese , diabetic, had a very high number of dead inflammatory cells in circulation. While this is a...very interesting finding, it is more likely that the dead inflammatory cells are coming from the obesity and severe diabetes. Because of this severe
Beta-Band Oscillations Represent Auditory Beat and Its Metrical Hierarchy in Perception and Imagery.
Fujioka, Takako; Ross, Bernhard; Trainor, Laurel J
2015-11-11
Dancing to music involves synchronized movements, which can be at the basic beat level or higher hierarchical metrical levels, as in a march (groups of two basic beats, one-two-one-two …) or waltz (groups of three basic beats, one-two-three-one-two-three …). Our previous human magnetoencephalography studies revealed that the subjective sense of meter influences auditory evoked responses phase locked to the stimulus. Moreover, the timing of metronome clicks was represented in periodic modulation of induced (non-phase locked) β-band (13-30 Hz) oscillation in bilateral auditory and sensorimotor cortices. Here, we further examine whether acoustically accented and subjectively imagined metric processing in march and waltz contexts during listening to isochronous beats were reflected in neuromagnetic β-band activity recorded from young adult musicians. First, we replicated previous findings of beat-related β-power decrease at 200 ms after the beat followed by a predictive increase toward the onset of the next beat. Second, we showed that the β decrease was significantly influenced by the metrical structure, as reflected by differences across beat type for both perception and imagery conditions. Specifically, the β-power decrease associated with imagined downbeats (the count "one") was larger than that for both the upbeat (preceding the count "one") in the march, and for the middle beat in the waltz. Moreover, beamformer source analysis for the whole brain volume revealed that the metric contrasts involved auditory and sensorimotor cortices; frontal, parietal, and inferior temporal lobes; and cerebellum. We suggest that the observed β-band activities reflect a translation of timing information to auditory-motor coordination. With magnetoencephalography, we examined β-band oscillatory activities around 20 Hz while participants listened to metronome beats and imagined musical meters such as a march and waltz. We demonstrated that β-band event-related desynchronization in the auditory cortex differentiates between beat positions, specifically between downbeats and the following beat. This is the first demonstration of β-band oscillations related to hierarchical and internalized timing information. Moreover, the meter representation in the β oscillations was widespread across the brain, including sensorimotor and premotor cortices, parietal lobe, and cerebellum. The results extend current understanding of the role of β oscillations in neural processing of predictive timing. Copyright © 2015 the authors 0270-6474/15/3515187-12$15.00/0.
Adeleye, Olushola Emmanuel; Ale, Jude Makinde; Sogebi, Emmanuella Olubanke Amope; Durotoye, Ladoke A; Adeleye, Adenike Iyabo; Adeyemi, Samuel Olufemi; Olukunle, Johnny Olufemi
2018-03-23
This study was carried out to determine the blood pressure changes in experimentally Trypanosoma brucei brucei-infected Wistar albino rats and diminazene aceturate-treated rats. Twenty-four rats were purchased and divided into four groups consisting of six rats each. Control group (CON) received 0.5 mL of distilled water, i.m., infected but not treated group (INF) received 2×106 trypanosome/mL i.m., infected but diminazene aceturate-treated group (INFDIM) received 2×106 trypanosome/mL, 3.5 mg/kg, i.m.) and non-infected but diminazene aceturate-treated group (DIM) received 3.5 mg/kg, i.m. and served as negative control. The blood pressures were measured using a CODA 2® non-invasive blood pressure monitor (Kent Scientific, USA). The results were compiled and statistical analysis was done with significance set at p≥0.05. The values of the blood pressure readings of the Trypanosoma-infected INF (137.0±2.0 mmHg) and diminazene-treated rats INFDIM (125.0±7.5 mmHg) when compared to the control group (168.0±3.0 mmHg) were significantly lower (p≤0.05) at the end of day 7. The heart rate was also significantly reduced in the INF (403.5±1.5 beats/min) and DIM (445.0±24 beats/min) groups of rats when compared with the control group (613.0±2.0 beats/min) at the end of day 8. The findings indicate the significant reduction in blood pressure and heart rates during Trypanosoma brucei brucei infection and with diminazene aceturate administration. Hence, caution should be exercised when treating trypanosome-infected patients with diminazene aceturate.
Autonomic Nervous System Disorders
Your autonomic nervous system is the part of your nervous system that controls involuntary actions, such as the beating of your heart ... breathing and swallowing Erectile dysfunction in men Autonomic nervous system disorders can occur alone or as the result ...
NASA Astrophysics Data System (ADS)
Nikolai Aljuri, A.; Bursac, Nenad; Marini, Robert; Cohen, Richard J.
2001-08-01
Prolonged exposure to microgravity in space flight missions (days) impairs the mechanisms responsible for defense of arterial blood pressure (ABP) and cardiac output (CO) against orthostatic stress in the post-flight period. The mechanisms responsible for the observed orthostatic intolerance are not yet completely understood. Additionally, effective counter measures to attenuate this pathophysiological response are not available. The aim of this study was to investigate the ability of our proposed system identification method to predict closed-loop dynamic changes in TPR induced by changes in mean arterial pressure (MAP) and right atrial pressure (RAP). For this purpose we designed and employed a novel experimental animal model for the examination of arterial and cardiopulmonary baroreceptors in the dynamic closed-loop control of total peripheral resistance (TPR), and applied system identification to the analysis of beat-to-beat fluctuations in the measured signals.
What can we learn about beat perception by comparing brain signals and stimulus envelopes?
Henry, Molly J; Herrmann, Björn; Grahn, Jessica A
2017-01-01
Entrainment of neural oscillations on multiple time scales is important for the perception of speech. Musical rhythms, and in particular the perception of a regular beat in musical rhythms, is also likely to rely on entrainment of neural oscillations. One recently proposed approach to studying beat perception in the context of neural entrainment and resonance (the "frequency-tagging" approach) has received an enthusiastic response from the scientific community. A specific version of the approach involves comparing frequency-domain representations of acoustic rhythm stimuli to the frequency-domain representations of neural responses to those rhythms (measured by electroencephalography, EEG). The relative amplitudes at specific EEG frequencies are compared to the relative amplitudes at the same stimulus frequencies, and enhancements at beat-related frequencies in the EEG signal are interpreted as reflecting an internal representation of the beat. Here, we show that frequency-domain representations of rhythms are sensitive to the acoustic features of the tones making up the rhythms (tone duration, onset/offset ramp duration); in fact, relative amplitudes at beat-related frequencies can be completely reversed by manipulating tone acoustics. Crucially, we show that changes to these acoustic tone features, and in turn changes to the frequency-domain representations of rhythms, do not affect beat perception. Instead, beat perception depends on the pattern of onsets (i.e., whether a rhythm has a simple or complex metrical structure). Moreover, we show that beat perception can differ for rhythms that have numerically identical frequency-domain representations. Thus, frequency-domain representations of rhythms are dissociable from beat perception. For this reason, we suggest caution in interpreting direct comparisons of rhythms and brain signals in the frequency domain. Instead, we suggest that combining EEG measurements of neural signals with creative behavioral paradigms is of more benefit to our understanding of beat perception.
Molina, Cristina E; Llach, Anna; Herraiz-Martínez, Adela; Tarifa, Carmen; Barriga, Montserrat; Wiegerinck, Rob F; Fernandes, Jacqueline; Cabello, Nuria; Vallmitjana, Alex; Benitéz, Raúl; Montiel, José; Cinca, Juan; Hove-Madsen, Leif
2016-01-01
Atrial fibrillation (AF) has been associated with increased spontaneous calcium release from the sarcoplasmic reticulum and linked to increased adenosine A2A receptor (A2AR) expression and activation. Here we tested whether this may favor atrial arrhythmogenesis by promoting beat-to-beat alternation and irregularity. Patch-clamp and confocal calcium imaging was used to measure the beat-to-beat response of the calcium current and transient in human atrial myocytes. Responses were classified as uniform, alternating or irregular and stimulation of Gs-protein coupled receptors decreased the frequency where a uniform response could be maintained from 1.0 ± 0.1 to 0.6 ± 0.1 Hz; p < 0.01 for beta-adrenergic receptors and from 1.4 ± 0.1 to 0.5 ± 0.1 Hz; p < 0.05 for A2ARs. The latter was linked to increased spontaneous calcium release and after-depolarizations. Moreover, A2AR activation increased the fraction of non-uniformly responding cells in HL-1 myocyte cultures from 19 ± 3 to 51 ± 9 %; p < 0.02, and electrical mapping in perfused porcine atria revealed that adenosine induced electrical alternans at longer cycle lengths, doubled the fraction of electrodes showing alternation, and increased the amplitude of alternations. Importantly, protein kinase A inhibition increased the highest frequency where uniform responses could be maintained from 0.84 ± 0.12 to 1.86 ± 0.11 Hz; p < 0.001 and prevention of A2AR-activation with exogenous adenosine deaminase selectively increased the threshold from 0.8 ± 0.1 to 1.2 ± 0.1 Hz; p = 0.001 in myocytes from patients with AF. In conclusion, A2AR-activation promotes beat-to-beat irregularities in the calcium transient in human atrial myocytes, and prevention of A2AR activation may be a novel means to maintain uniform beat-to-beat responses at higher beating frequencies in patients with atrial fibrillation.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Variation of Ciliary Beat Pattern in Three Different Beating Planes in Healthy Subjects.
Kempeneers, Celine; Seaton, Claire; Chilvers, Mark A
2017-05-01
Digital high-speed video microscopy (DHSV) allows analysis of ciliary beat frequency (CBF) and ciliary beat pattern (CBP) of respiratory cilia in three planes. Normal reference data use a sideways edge to evaluate ciliary dyskinesia and calculate CBF using the time needed for a cilium to complete 10 beat cycles. Variability in CBF within the respiratory epithelium has been described, but data concerning variation of CBP is limited in healthy epithelium. This study aimed to document variability of CBP in normal samples, to compare ciliary function in three profiles, and to compare CBF calculated over five or 10 beat cycles. Nasal brushing samples from 13 healthy subjects were recorded using DHSV in three profiles. CBP and CBF over a 10-beat cycle were evaluated in all profiles, and CBF was reevaluated over five-beat cycles in the sideways edges. A uniform CBP was seen in 82.1% of edges. In the sideways profile, uniformity within the edge was lower (uniform normal CBP, 69.1% [sideways profile]; 97.1% [toward the observer], 92.0% [from above]), and dyskinesia was higher. Interobserver agreement for dyskinesia was poor. CBF was not different between profiles (P = .8097) or between 10 and five beat cycles (P = .1126). Our study demonstrates a lack of uniformity and consistency in manual CBP analysis of samples from healthy subjects, emphasizing the risk of automated CBP analysis in limited regions of interest and of single and limited manual CBP analysis. The toward the observer and from above profiles may be used to calculate CBF but may be less sensitive for evaluation of ciliary dyskinesia and CBP. CBF can be measured reliably by evaluation of only five-beat cycles. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Jones, Peter; Ovenden, Nick; Dauger, Stéphane; Peters, Mark J
2014-01-01
Reductions in heart rate occur frequently in children during critical care intubation and are currently considered the gold standard for haemodynamic instability. Our objective was to estimate loss of heart beats during intubation and compare this to reduction in heart rate alone whilst testing the impact of atropine pre-medication. Data were extracted from a prospective 2-year cohort study of intubation ECGs from critically ill children in PICU/Paediatric Transport. A three step algorithm was established to exclude variation in pre-intubation heart rate (using a 95%CI limit derived from pre-intubation heart rate variation of the children included), measure the heart rate over time and finally the estimate the numbers of lost beats. 333 intubations in children were eligible for inclusion of which 245 were available for analysis (74%). Intubations where the fall in heart rate was less than 50 bpm were accompanied almost exclusively by less than 25 lost beats (n = 175, median 0 [0-1]). When there was a reduction of >50 bpm there was a poor correlation with numbers of lost beats (n = 70, median 42 [15-83]). During intubation the median number of lost beats was 8 [1]-[32] when atropine was not used compared to 0 [0-0] when atropine was used (p<0.001). A reduction in heart rate during intubation of <50 bpm reliably predicted a minimal loss of beats. When the reduction in heart rate was >50 bpm the heart rate was poorly predictive of lost beats. A study looking at the relationship between lost beats and cardiac output needs to be performed. Atropine reduces both fall in heart rate and loss of beats. Similar area-under-the-curve methodology may be useful for estimating risk when biological parameters deviate outside normal range.
Kriščiukaitis, Algimantas; Šimoliūnienė, Renata; Macas, Andrius; Petrolis, Robertas; Drėgūnas, Kęstutis; Bakšytė, Giedrė; Pieteris, Linas; Bertašienė, Zita; Žaliūnas, Remigijus
2014-01-01
Beat-to-beat alteration in ventricles repolarization reflected by alternans of amplitude and/or shape of ECG S-T,T segment (TWA) is known as phenomena related with risk of severe arrhythmias leading to sudden cardiac death. Technical difficulties have caused limited its usage in clinical diagnostics. Possibilities to register and analyze multimodal signals reflecting heart activity inspired search for new technical solutions. First objective of this study was to test whether thoracic impedance signal and beat-to-beat heart rate reflect repolarization alternans detected as TWA. The second objective was revelation of multimodal signal features more comprehensively representing the phenomena and increasing its prognostic usefulness. ECG, and thoracic impedance signal recordings made during 24h follow-up of the patients hospitalized in acute phase of myocardial infarction were used for investigation. Signal morphology variations reflecting estimates were obtained by the principal component analysis-based method. Clinical outcomes of patients (survival and/or rehospitalization in 6 and 12 months) were compared to repolarization alternans and heart rate variability estimates. Repolarization alternans detected as TWA was also reflected in estimates of thoracic impedance signal shape and variation in beat-to-beat heart rate. All these parameters showed correlation with clinical outcomes of patients. The strongest significant correlation showed magnitude of alternans in estimates of thoracic impedance signal shape. The features of ECG, thoracic impedance signal and beat-to-beat variability of heart rate, give comprehensive estimates of repolarization alternans, which correlate, with clinical outcomes of the patients and we recommend using them to improve diagnostic reliability. Copyright © 2014 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Breakfast high in whey protein or carbohydrates improves coping with workload in healthy subjects.
Sihvola, Nora; Korpela, Riitta; Henelius, Andreas; Holm, Anu; Huotilainen, Minna; Müller, Kiti; Poussa, Tuija; Pettersson, Kati; Turpeinen, Anu; Peuhkuri, Katri
2013-11-14
Dietary components may affect brain function and influence behaviour by inducing the synthesis of neurotransmitters. The aim of the present study was to examine the influence of consumption of a whey protein-containing breakfast drink v. a carbohydrate drink v. control on subjective and physiological responses to mental workload in simulated work. In a randomised cross-over design, ten healthy subjects (seven women, median age 26 years, median BMI 23 kg/m(2)) participated in a single-blinded, placebo-controlled study. The subjects performed demanding work-like tasks after having a breakfast drink high in protein (HP) or high in carbohydrate (HC) or a control drink on separate sessions. Subjective states were assessed using the NASA Task Load Index (NASA-TLX), the Karolinska sleepiness scale (KSS) and the modified Profile of Mood States. Heart rate was recorded during task performance. The ratio of plasma tryptophan (Trp) to the sum of the other large neutral amino acids (LNAA) and salivary cortisol were also analysed. The plasma Trp:LNAA ratio was 30 % higher after the test drinks HP (median 0·13 (μmol/l)/(μmol/l)) and HC (median 0·13 (μmol/l)/(μmol/l)) than after the control drink (median 0·10 (μmol/l)/(μmol/l)). The increase in heart rate was smaller after the HP (median 2·7 beats/min) and HC (median 1·9 beats/min) drinks when compared with the control drink (median 7·2 beats/min) during task performance. Subjective sleepiness was reduced more after the HC drink (median KSS - 1·5) than after the control drink (median KSS - 0·5). There were no significant differences between the breakfast types in the NASA-TLX index, cortisol levels or task performance. We conclude that a breakfast drink high in whey protein or carbohydrates may improve coping with mental tasks in healthy subjects.
Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf
2017-08-01
Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.
Attitudes toward wife beating: a cross-country study in Asia.
Rani, Manju; Bonu, Sekhar
2009-08-01
Using demographic and health surveys conducted between 1998 and 2001 from seven countries (Armenia, Bangladesh, Cambodia, India, Kazakhstan, Nepal, and Turkey), the study found that acceptance of wife beating ranged from 29% in Nepal, to 57% in India (women only), and from 26% in Kazakhstan, to 56% in Turkey (men only). Increasing wealth predicted less acceptance of wife beating, except in Cambodia and Nepal. Higher education level was negatively associated with acceptance in Turkey and Bangladesh. Younger respondents justified wife beating more often, with some exceptions, showing persistent intergenerational transmission of gender norms. Working women were equally or more likely to justify wife beating compared to nonworking women. Men were significantly more likely to justify wife beating in Armenia, Nepal, and Turkey. Targeted proactive efforts are needed to change these norms, such as improving female literacy rates and other enabling factors.
Auditory beat stimulation and its effects on cognition and mood States.
Chaieb, Leila; Wilpert, Elke Caroline; Reber, Thomas P; Fell, Juergen
2015-01-01
Auditory beat stimulation may be a promising new tool for the manipulation of cognitive processes and the modulation of mood states. Here, we aim to review the literature examining the most current applications of auditory beat stimulation and its targets. We give a brief overview of research on auditory steady-state responses and its relationship to auditory beat stimulation (ABS). We have summarized relevant studies investigating the neurophysiological changes related to ABS and how they impact upon the design of appropriate stimulation protocols. Focusing on binaural-beat stimulation, we then discuss the role of monaural- and binaural-beat frequencies in cognition and mood states, in addition to their efficacy in targeting disease symptoms. We aim to highlight important points concerning stimulation parameters and try to address why there are often contradictory findings with regard to the outcomes of ABS.
Beat gestures help preschoolers recall and comprehend discourse information.
Llanes-Coromina, Judith; Vilà-Giménez, Ingrid; Kushch, Olga; Borràs-Comes, Joan; Prieto, Pilar
2018-08-01
Although the positive effects of iconic gestures on word recall and comprehension by children have been clearly established, less is known about the benefits of beat gestures (rhythmic hand/arm movements produced together with prominent prosody). This study investigated (a) whether beat gestures combined with prosodic information help children recall contrastively focused words as well as information related to those words in a child-directed discourse (Experiment 1) and (b) whether the presence of beat gestures helps children comprehend a narrative discourse (Experiment 2). In Experiment 1, 51 4-year-olds were exposed to a total of three short stories with contrastive words presented in three conditions, namely with prominence in both speech and gesture, prominence in speech only, and nonprominent speech. Results of a recall task showed that (a) children remembered more words when exposed to prominence in both speech and gesture than in either of the other two conditions and that (b) children were more likely to remember information related to those words when the words were associated with beat gestures. In Experiment 2, 55 5- and 6-year-olds were presented with six narratives with target items either produced with prosodic prominence but no beat gestures or produced with both prosodic prominence and beat gestures. Results of a comprehension task demonstrated that stories told with beat gestures were comprehended better by children. Together, these results constitute evidence that beat gestures help preschoolers not only to recall discourse information but also to comprehend it. Copyright © 2018 Elsevier Inc. All rights reserved.
Early Administration of Glutamine Protects Cardiomyocytes from Post-Cardiac Arrest Acidosis.
Lin, Yan-Ren; Li, Chao-Jui; Syu, Shih-Han; Wen, Cheng-Hao; Buddhakosai, Waradee; Wu, Han-Ping; Hsu Chen, Cheng; Lu, Huai-En; Chen, Wen-Liang
2016-01-01
Postcardiac arrest acidosis can decrease survival. Effective medications without adverse side effects are still not well characterized. We aimed to analyze whether early administration of glutamine could improve survival and protect cardiomyocytes from postcardiac arrest acidosis using animal and cell models. Forty Wistar rats with postcardiac arrest acidosis (blood pH < 7.2) were included. They were divided into study (500 mg/kg L-alanyl-L-glutamine, n = 20) and control (normal saline, n = 20) groups. Each of the rats received resuscitation. The outcomes were compared between the two groups. In addition, cardiomyocytes derived from human induced pluripotent stem cells were exposed to HBSS with different pH levels (7.3 or 6.5) or to culture medium (control). Apoptosis-related markers and beating function were analyzed. We found that the duration of survival was significantly longer in the study group ( p < 0.05). In addition, in pH 6.5 or pH 7.3 HBSS buffer, the expression levels of cell stress (p53) and apoptosis (caspase-3, Bcl-xL) markers were significantly lower in cardiomyocytes treated with 50 mM L-glutamine than those without L-glutamine (RT-PCR). L-glutamine also increased the beating function of cardiomyocytes, especially at the lower pH level (6.5). More importantly, glutamine decreased cardiomyocyte apoptosis and increased these cells' beating function at a low pH level.
[Effect of music on gait symmetry of stroke patients on a treadmill].
Schauer, M; Steingrüber, W; Mauritz, K H
1996-10-01
The influence of rhythmic music on gait symmetry was investigated in 12 healthy subjects and 12 stroke patients with mild leg paresis walking on the treadmill. For the measurement, new insoles containing air-filled chambers developed by W.O.M were used. Symmetry deviation was determined as the mean signless difference between left and right swing phases of some 100 strides. In 6 patients, the symmetry deviation decreased by more than 1% of the stride duration some 40 steps after switching on the music. The improvement correlated with the initial symmetry (r2 = 0.61) exclusively in the healthy controls. In order to differentiate individual predictors of the improvement in symmetry, such as cognitive performance in terms of recognizing the beat of the music and the motor performance in terms of synchronizing the movements of the legs to the music, we analysed foot tapping with the patient in the seated position. For both patients and healthy subjects, the mean time difference between beat and foot movement was less than +/-1/32 beat. Individual scatter of mean 8% correspond in the case of healthy subjects to the figures found in the literature for finger movements, and the corresponding figures for the patients are more than twice this. The individual synchronisation performance during walking to music correlates to that during foot tapping (r2 = 0.47) exclusively in the group of healthy controls.
NASA Technical Reports Server (NTRS)
Parkinson, John B; Olson, Roland E; House, Rufus O
1939-01-01
Three models of V-bottom floats for twin-float seaplanes (N.A.C.A. models 57-A, 57-B, and 57-C) having angles of dead rise of 20 degrees, 25 degrees, and thirty degrees, respectively, were tested in the N.A.C.A. tank and in the N.A.C.A. 7- by 10-foot wind tunnel. Within the range investigated, the effect of angle of dead rise on water resistance was found to be negligible at speeds up to and including the hump speed, and water resistance was found to increase with angle of dead rise at planing speeds. The height of the spray at the hump speed decreased with increase in angle of dead rise and the aerodynamic drag increased with dead rise. Lengthening the forebody of model 57-B decreased the water resistance and the spray at speeds below the hump speed. Spray strips provided an effective means for the control of spray with the straight V sections used in the series but considerably increased the aerodynamic drag. Charts for the determination of the water resistance and the static properties of the model with 25 degrees dead rise and for the aerodynamic drag of all the models are included for use in design.
Analyzing the acoustic beat with mobile devices
NASA Astrophysics Data System (ADS)
Kuhn, Jochen; Vogt, Patrik; Hirth, Michael
2014-04-01
In this column, we have previously presented various examples of how physical relationships can be examined by analyzing acoustic signals using smartphones or tablet PCs. In this example, we will be exploring the acoustic phenomenon of small beats, which is produced by the overlapping of two tones with a low difference in frequency Δf. The resulting auditory sensation is a tone with a volume that varies periodically. Acoustic beats can be perceived repeatedly in day-to-day life and have some interesting applications. For example, string instruments are still tuned with the help of an acoustic beat, even with modern technology. If a reference tone (e.g., 440 Hz) and, for example, a slightly out-of-tune violin string produce a tone simultaneously, a beat can be perceived. The more similar the frequencies, the longer the duration of the beat. In the extreme case, when the frequencies are identical, a beat no longer arises. The string is therefore correctly tuned. Using the Oscilloscope app,4 it is possible to capture and save acoustic signals of this kind and determine the beat frequency fS of the signal, which represents the difference in frequency Δf of the two overlapping tones (for Android smartphones, the app OsciPrime Oscilloscope can be used).
Di Rienzo, Marco; Vaini, Emanuele; Lombardi, Prospero
2017-11-15
Seismocardiogram, SCG, is the measure of precordial vibrations produced by the beating heart, from which cardiac mechanics may be explored on a beat-to-beat basis. We recently collected a large amount of SCG data (>69 recording hours) from an astronaut to investigate cardiac mechanics during sleep aboard the International Space Station and on Earth. SCG sleep recordings are characterized by a prolonged duration and wide heart rate swings, thus a specific algorithm was developed for their analysis. In this article we describe the new algorithm and its performance. The algorithm is composed of three parts: 1) artifacts removal, 2) identification in each SCG waveform of four fiducial points associated with the opening and closure of the aortic and mitral valves, 3) beat-to-beat computation of indexes of cardiac mechanics from the SCG fiducial points. The algorithm was tested on two sleep recordings and yielded the identification of the fiducial points in more than 36,000 beats with a precision, quantified by the Positive Predictive Value, ≥99.2%. These positive findings provide the first evidence that cardiac mechanics may be explored by the automatic analysis of SCG long-lasting recordings, taken out of the laboratory setting, and in presence of significant heart rate modulations.
Serum S100B protein concentration in brain-dead organ donors: a pilot study.
Krzych, Łukasz J; Czempik, Piotr Filip; Saucha, Wojciech; Kokocińska, Danuta; Knapik, Piotr
2015-01-01
Protein S100B is considered to be a marker of brain damage, but there is a paucity of data regarding the utility of its assessment in brain-dead organ donors. The aim of the study was to compare serum protein S100B concentrations between brain-dead organ donors and patients with a confirmed permanent neurological deficit but without signs of brain death. The concentration of serum S100B protein was measured in 12 brain-dead organ donors (including 7 males with a median age of 40 years). All measurements were taken when brain death was confirmed by the commission. Twenty-nine patients (including 13 males with a median age of 63 years) who died in the medical ICU with confirmed permanent brain injury without signs of brain death acted as controls. In these patients, S-100B protein measurements were performed upon ICU admission. In brain-dead organ donors, the median values of serum S100B protein were much higher in comparison to the control group (median and IQR, respectively: 5.04 μg L⁻¹; 1.775-6.765 vs 0.897 μg L⁻¹; 0.324-1.880, P < 0.001). S100B serum values > 1.81 μg L⁻¹ predicted brain death with the highest accuracy (AUROC = 0.83; 95% CI 0.68-0.93; P < 0.001). Concentrations of serum S100B protein in brain-dead organ donors are extremely high and may support the diagnosis of brain death. This fact may be of value when the presence of reflex movements (frequently reported despite brain death) might delay determination of brain death and result in the failure of organ donation.
Digital approach to stabilizing optical frequency combs and beat notes of CW lasers
NASA Astrophysics Data System (ADS)
Čížek, Martin; Číp, Ondřej; Å míd, Radek; Hrabina, Jan; Mikel, Břetislav; Lazar, Josef
2013-10-01
In cases when it is necessary to lock optical frequencies generated by an optical frequency comb to a precise radio frequency (RF) standard (GPS-disciplined oscillator, H-maser, etc.) the usual practice is to implement phase and frequency-locked loops. Such system takes the signal generated by the RF standard (usually 10 MHz or 100 MHz) as a reference and stabilizes the repetition and offset frequencies of the comb contained in the RF output of the f-2f interferometer. These control loops are usually built around analog electronic circuits processing the output signals from photo detectors. This results in transferring the stability of the standard from RF to optical frequency domain. The presented work describes a different approach based on digital signal processing and software-defined radio algorithms used for processing the f-2f and beat-note signals. Several applications of digital phase and frequency locks to a RF standard are demonstrated: the repetition (frep) and offset frequency (fceo) of the comb, and the frequency of the beat note between a CW laser source and a single component of the optical frequency comb spectrum.
Visual Timing of Structured Dance Movements Resembles Auditory Rhythm Perception
Su, Yi-Huang; Salazar-López, Elvira
2016-01-01
Temporal mechanisms for processing auditory musical rhythms are well established, in which a perceived beat is beneficial for timing purposes. It is yet unknown whether such beat-based timing would also underlie visual perception of temporally structured, ecological stimuli connected to music: dance. In this study, we investigated whether observers extracted a visual beat when watching dance movements to assist visual timing of these movements. Participants watched silent videos of dance sequences and reproduced the movement duration by mental recall. We found better visual timing for limb movements with regular patterns in the trajectories than without, similar to the beat advantage for auditory rhythms. When movements involved both the arms and the legs, the benefit of a visual beat relied only on the latter. The beat-based advantage persisted despite auditory interferences that were temporally incongruent with the visual beat, arguing for the visual nature of these mechanisms. Our results suggest that visual timing principles for dance parallel their auditory counterparts for music, which may be based on common sensorimotor coupling. These processes likely yield multimodal rhythm representations in the scenario of music and dance. PMID:27313900
Visual Timing of Structured Dance Movements Resembles Auditory Rhythm Perception.
Su, Yi-Huang; Salazar-López, Elvira
2016-01-01
Temporal mechanisms for processing auditory musical rhythms are well established, in which a perceived beat is beneficial for timing purposes. It is yet unknown whether such beat-based timing would also underlie visual perception of temporally structured, ecological stimuli connected to music: dance. In this study, we investigated whether observers extracted a visual beat when watching dance movements to assist visual timing of these movements. Participants watched silent videos of dance sequences and reproduced the movement duration by mental recall. We found better visual timing for limb movements with regular patterns in the trajectories than without, similar to the beat advantage for auditory rhythms. When movements involved both the arms and the legs, the benefit of a visual beat relied only on the latter. The beat-based advantage persisted despite auditory interferences that were temporally incongruent with the visual beat, arguing for the visual nature of these mechanisms. Our results suggest that visual timing principles for dance parallel their auditory counterparts for music, which may be based on common sensorimotor coupling. These processes likely yield multimodal rhythm representations in the scenario of music and dance.
NASA Astrophysics Data System (ADS)
Bari, Vlasta; Marchi, Andrea; De Maria, Beatrice; Rossato, Gianluca; Nollo, Giandomenico; Faes, Luca; Porta, Alberto
2016-05-01
Cardiovascular and cerebrovascular regulatory systems are vital control mechanisms responsible for guaranteeing homeostasis and are affected by respiration. This work proposes the investigation of cardiovascular and cerebrovascular control systems and the nonlinear influences of respiration on both regulations through joint symbolic analysis (JSA), conditioned or unconditioned on respiration. Interactions between cardiovascular and cerebrovascular regulatory systems were evaluated as well by performing correlation analysis between JSA indexes describing the two control systems. Heart period, systolic and mean arterial pressure, mean cerebral blood flow velocity and respiration were acquired on a beat-to-beat basis in 13 subjects experiencing recurrent syncope episodes (SYNC) and 13 healthy individuals (non-SYNC) in supine resting condition and during head-up tilt test at 60° (TILT). Results showed that JSA distinguished conditions and groups, whereas time domain parameters detected only the effect of TILT. Respiration affected cardiovascular and cerebrovascular regulatory systems in a nonlinear way and was able to modulate the interactions between the two control systems with different outcome in non-SYNC and SYNC groups, thus suggesting that the analysis of the impact of respiration on cardiovascular and cerebrovascular regulatory systems might improve our understanding of the mechanisms underpinning the development of postural-related syncope.
View from... JSAP Spring Meeting 2016: Ultrashort interactions
NASA Astrophysics Data System (ADS)
Horiuchi, Noriaki
2016-06-01
At the 63rd Spring Meeting of the Japan Society of Applied Physics, scientists described how femtosecond laser pulses can be used to perform tasks such as quantum beat spectroscopy, control of magnetization, cell sorting and crystal growth.
Brad Oberle; Kiona Ogle; Amy E. Zanne; Christopher W. Woodall
2018-01-01
When standing dead trees (snags) fall, they have major impacts on forest ecosystems. Snag fall can redistribute wildlife habitat and impact public safety, while governing important carbon (C) cycle consequences of tree mortality because ground contact accelerates C emissions during deadwood decay. Managing the consequences of altered snag dynamics in changing forests...
The role of birds in arboviral disease surveillance in Harris County and the City of Houston, Texas.
Wilkerson, Lauren; Reyna Nava, Martin; Battle-Freeman, Cheryl; Travassos da Rosa, Amelia; Guzman, Hilda; Tesh, Robert; Debboun, Mustapha
2017-01-01
Avian arboviral surveillance is an integral part of any disease-based integrated mosquito control program. The Harris County Public Health Mosquito and Vector Control Division has performed arboviral surveillance in the wild birds of Harris County and the City of Houston since 1965. Blood samples from live trapped birds were tested for arboviral antibodies to West Nile virus (WNV), St. Louis encephalitis, Eastern equine encephalitis, and Western equine encephalitis. A dead bird surveillance program was created in 2002 with the arrival of WNV in Harris County. Since implementation, the program has detected considerable variability in viral activity with annual WNV seroprevelance rates ranging from 2.9% to 17.7%, while the percentage of positive dead birds has ranged from 0.3% to 57.2%. In 2015, 1,345 live birds were sampled and 253 dead birds were tested, with WNV incidence rates of 16.5% and 5.9%, respectively.
Dead sea asphalts: historical aspects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nissenbaum, A.
1978-05-01
Asphalts are present in the Dead Sea basin in three forms: (1) huge blocks, up to 100 tons in weight, composed of extremely pure (>99.99%) solid asphalt occasionally found floating on the lake, (2) veins, seepages, and cavity and fissure fillings in Lower Cretaceous to Holocene rocks, and (3) ozocerite veins on the eastern shore of the lake. Dead Sea asphalts probably have been documented over a longer period of time than any other hydrocarbon deposit--from antiquity to the 19th century. Major uses of asphalt from the Dead Sea have been as an ingredient in the embalming process, for medicinalmore » purposes, for fumigation, and for agriculture. The first known war for control of a hydrocarbon deposit was in the Dead Sea area in 312 B.C. between the Seleucid Syrians and the Nabatean Arabs who lived around the lake. Surface manifestations of asphalt are linked closely to tectonic activity. In the lake itself, the asphalt is associated with diapirs During certain historic periods, tectonic and diapiric activity caused frequent liberation to the Dead Sea surface of semiliquid asphalt associated with large amounts of hydrogen sulfide gas. When the tectonic activity was attenuated, as in the 19th and 20th centuries, the rate of asphalt seepage to the bottom sediments of the Dead Sea was much slower and the asphalt solidified on the lake bottom. The release of asphalt to the surface became much more sporadic, and may have resulted in part from earthquakes. Thus, future asphalt prospecting in the Dead Sea area should be conducted along the boundaries of diapirs or their associated faults.« less
Survey of Methods to Assess Workload
1979-08-01
thesis study which had to do with the effect of binaural beats upon performan:.e (2) found out there was a subjectively experienced quality of beats ...were forced to conclude that the neuralmechanism by which binaural beats influenced performance is not open to correct subjective evaluation. In terms of...methods for developing indicies of pilot workload, FAA Report (FAA-AN-77- 15), July 1977. 2. ,’ R. E. The effect of binaural beats on performance, J
Beat Perception and Sociability: Evidence from Williams Syndrome
Lense, Miriam D.; Dykens, Elisabeth M.
2016-01-01
Beat perception in music has been proposed to be a human universal that may have its origins in adaptive processes involving temporal entrainment such as social communication and interaction. We examined beat perception skills in individuals with Williams syndrome (WS), a genetic, neurodevelopmental disorder. Musical interest and hypersociability are two prominent aspects of the WS phenotype although actual musical and social skills are variable. On a group level, beat and meter perception skills were poorer in WS than in age-matched peers though there was significant individual variability. Cognitive ability, sound processing style, and musical training predicted beat and meter perception performance in WS. Moreover, we found significant relationships between beat and meter perception and adaptive communication and socialization skills in WS. Results have implications for understanding the role of predictive timing in both music and social interactions in the general population, and suggest music as a promising avenue for addressing social communication difficulties in WS. PMID:27378982
ECG signal analysis through hidden Markov models.
Andreão, Rodrigo V; Dorizzi, Bernadette; Boudy, Jérôme
2006-08-01
This paper presents an original hidden Markov model (HMM) approach for online beat segmentation and classification of electrocardiograms. The HMM framework has been visited because of its ability of beat detection, segmentation and classification, highly suitable to the electrocardiogram (ECG) problem. Our approach addresses a large panel of topics some of them never studied before in other HMM related works: waveforms modeling, multichannel beat segmentation and classification, and unsupervised adaptation to the patient's ECG. The performance was evaluated on the two-channel QT database in terms of waveform segmentation precision, beat detection and classification. Our waveform segmentation results compare favorably to other systems in the literature. We also obtained high beat detection performance with sensitivity of 99.79% and a positive predictivity of 99.96%, using a test set of 59 recordings. Moreover, premature ventricular contraction beats were detected using an original classification strategy. The results obtained validate our approach for real world application.
Auditory Beat Stimulation and its Effects on Cognition and Mood States
Chaieb, Leila; Wilpert, Elke Caroline; Reber, Thomas P.; Fell, Juergen
2015-01-01
Auditory beat stimulation may be a promising new tool for the manipulation of cognitive processes and the modulation of mood states. Here, we aim to review the literature examining the most current applications of auditory beat stimulation and its targets. We give a brief overview of research on auditory steady-state responses and its relationship to auditory beat stimulation (ABS). We have summarized relevant studies investigating the neurophysiological changes related to ABS and how they impact upon the design of appropriate stimulation protocols. Focusing on binaural-beat stimulation, we then discuss the role of monaural- and binaural-beat frequencies in cognition and mood states, in addition to their efficacy in targeting disease symptoms. We aim to highlight important points concerning stimulation parameters and try to address why there are often contradictory findings with regard to the outcomes of ABS. PMID:26029120
Afra, Elyas; Yousefi, Hossein; Hadilam, Mohamad Mahdi; Nishino, Takashi
2013-09-12
Cellulose fibers were fibrillated using mechanical beating (shearing refiner) and ultra-fine friction grinder, respectively. The fibrillated fibers were then used to make paper. Mechanical beating process created a partial skin fibrillation, while grinding turned fiber from micro to nanoscale through nanofibrillation mechanism. The partially fibrillated and nano fibrillated fibers had significant effects on paper density, tear strength, tensile strength and water drainage time. The effect of nanofibrillation on paper properties was quantitatively higher than that of mechanical beating. Paper sheets from nanofibrillated cellulose have a higher density, higher tensile strength and lower tear strength compared to those subjected to mechanical beating. Mechanical beating and nanofibrillation were both found to be promising fiber structural modifications. Long water drainage time was an important drawback of both fibrillation methods. Copyright © 2013 Elsevier Ltd. All rights reserved.
Influences of rolling method on deformation force in cold roll-beating forming process
NASA Astrophysics Data System (ADS)
Su, Yongxiang; Cui, Fengkui; Liang, Xiaoming; Li, Yan
2018-03-01
In process, the research object, the gear rack was selected to study the influence law of rolling method on the deformation force. By the mean of the cold roll forming finite element simulation, the variation regularity of radial and tangential deformation was analysed under different rolling methods. The variation of deformation force of the complete forming racks and the single roll during the steady state under different rolling modes was analyzed. The results show: when upbeating and down beating, radial single point average force is similar, the tangential single point average force gap is bigger, the gap of tangential single point average force is relatively large. Add itionally, the tangential force at the time of direct beating is large, and the dire ction is opposite with down beating. With directly beating, deformation force loading fast and uninstall slow. Correspondingly, with down beating, deformat ion force loading slow and uninstall fast.
Active Motion Control of Tetrahymena pyriformis by Galvanotaxis and Geotaxis
NASA Astrophysics Data System (ADS)
Kim, Jihoon; Byun, Doyoung; Kim, Min Jun
2013-11-01
Recently, there has been increasing interest in the swimming behavior of microorganisms and biologically inspired micro-robots. These microorganisms naturally accompanied by complex motions. Therefore it is important to understand the flow characteristics as well as control mechanisms. One of eukaryotic cells, the protozoa are a diverse group of unicellular organisms, many of which are motile cilia. Motile cilia are cover on the surface of cell in large numbers and beat in oriented waves. Sequential beating motions of a single cilium form metachronal strokes, producing a propagation wave, and therefore the body is achieved propulsion force. So preliminary studies are achieved to understand the flow induced by swimming microorganisms. Based on hydrodynamic results, the follow study of a few micro-scale protozoa cell, such as the Tetrahymena pyriformis, has provided active or passive control into several external stimuli. In typical control methods, the galvanotaxis and geotaxis were adopted active and passive control, respectively. The validation of galvanotaxis is used DC and AC voltage. In terms of geotaxis, corrugated microstructures were used to control in the microchannel. This research was supported by the Ministry of Education, Science and Technology (MEST, 2011-0016461), National Science Foundation (NSF) CMMI Control Systems Program (#1000255) and Army Research Office (W911NF-11-1-0490).
Ivabradine in stable coronary artery disease without clinical heart failure.
Fox, Kim; Ford, Ian; Steg, Philippe Gabriel; Tardif, Jean-Claude; Tendera, Michal; Ferrari, Roberto
2014-09-18
An elevated heart rate is an established marker of cardiovascular risk. Previous analyses have suggested that ivabradine, a heart-rate-reducing agent, may improve outcomes in patients with stable coronary artery disease, left ventricular dysfunction, and a heart rate of 70 beats per minute or more. We conducted a randomized, double-blind, placebo-controlled trial of ivabradine, added to standard background therapy, in 19,102 patients who had both stable coronary artery disease without clinical heart failure and a heart rate of 70 beats per minute or more (including 12,049 patients with activity-limiting angina [class ≥II on the Canadian Cardiovascular Society scale, which ranges from I to IV, with higher classes indicating greater limitations on physical activity owing to angina]). We randomly assigned patients to placebo or ivabradine, at a dose of up to 10 mg twice daily, with the dose adjusted to achieve a target heart rate of 55 to 60 beats per minute. The primary end point was a composite of death from cardiovascular causes or nonfatal myocardial infarction. At 3 months, the mean (±SD) heart rate of the patients was 60.7±9.0 beats per minute in the ivabradine group versus 70.6±10.1 beats per minute in the placebo group. After a median follow-up of 27.8 months, there was no significant difference between the ivabradine group and the placebo group in the incidence of the primary end point (6.8% and 6.4%, respectively; hazard ratio, 1.08; 95% confidence interval, 0.96 to 1.20; P=0.20), nor were there significant differences in the incidences of death from cardiovascular causes and nonfatal myocardial infarction. Ivabradine was associated with an increase in the incidence of the primary end point among patients with activity-limiting angina but not among those without activity-limiting angina (P=0.02 for interaction). The incidence of bradycardia was higher with ivabradine than with placebo (18.0% vs. 2.3%, P<0.001). Among patients who had stable coronary artery disease without clinical heart failure, the addition of ivabradine to standard background therapy to reduce the heart rate did not improve outcomes. (Funded by Servier; SIGNIFY Current Controlled Trials number, ISRCTN61576291.).
Roerdink, Melvyn; Bank, Paulina J M; Peper, C Lieke E; Beek, Peter J
2011-04-01
Acoustic rhythms are frequently used in gait rehabilitation, with positive instantaneous and prolonged transfer effects on various gait characteristics. The gait modifying ability of acoustic rhythms depends on how well gait is tied to the beat, which can be assessed with measures of relative timing of auditory-motor coordination. We examined auditory-motor coordination in 20 healthy elderly individuals walking to metronome beats with pacing frequencies slower than, equal to, and faster than their preferred cadence. We found that more steps were required to adjust gait to the beat, the more the metronome rate deviated from the preferred cadence. Furthermore, participants anticipated the beat with their footfalls to various degrees, depending on the metronome rate; the faster the tempo, the smaller the phase advance or phase lead. Finally, the variability in the relative timing between footfalls and the beat was smaller for metronome rates closer to the preferred cadence, reflecting superior auditory-motor coordination. These observations have three practical implications. First, instantaneous effects of acoustic stimuli on gait characteristics may typically be underestimated given the considerable number of steps required to attune gait to the beat in combination with the usual short walkways. Second, a systematic phase lead of footfalls to the beat does not necessarily reflect a reduced ability to couple gait to the metronome. Third, the efficacy of acoustic rhythms to modify gait depends on metronome rate. Gait is coupled best to the beat for metronome rates near the preferred cadence. Copyright © 2011 Elsevier B.V. All rights reserved.
Di Rienzo, Marco; Vaini, Emanuele; Castiglioni, Paolo; Meriggi, Paolo; Rizzo, Francesco
2013-01-01
Seismocardiogram (SCG) is the measure of the minute vibrations produced by the beating heart. We previously demonstrated that SCG, ECG and respiration could be recorded over the 24 h during spontaneous behavior by a smart garment, the MagIC-SCG system. In the present case study we explored the feasibility of a beat-to-beat estimation of two indices of heart contractility, the Left Ventricular Ejection Time (LVET) and the electromechanical systole (QS2) from SCG and ECG recordings obtained by the MagIC-SCG device in one subject. We considered data collected during outdoor spontaneous behavior (while sitting in the metro and in the office) and in a laboratory setting (in supine and sitting posture, and during recovery after 100 W and 140 W cycling). LVET was estimated from SCG as the time interval between the opening and closure of the aortic valve, QS2 as the time interval between the Q wave of the ECG and the closure of the aortic valve. In every condition, LVET and QS2 could be estimated on a beat-to-beat basis from the SCG collected by the smart garment. LVET and QS2 are characterized by important beat-to-beat fluctuations, with standard deviations in the same order of magnitude of RR Interval. In all settings, spectral profiles are different for LVET, QS2 and RR Interval. This suggests that the biological mechanisms impinging on the heart exert a differentiated influence on the variability of each of these three indices.
Neural Entrainment to Auditory Imagery of Rhythms.
Okawa, Haruki; Suefusa, Kaori; Tanaka, Toshihisa
2017-01-01
A method of reconstructing perceived or imagined music by analyzing brain activity has not yet been established. As a first step toward developing such a method, we aimed to reconstruct the imagery of rhythm, which is one element of music. It has been reported that a periodic electroencephalogram (EEG) response is elicited while a human imagines a binary or ternary meter on a musical beat. However, it is not clear whether or not brain activity synchronizes with fully imagined beat and meter without auditory stimuli. To investigate neural entrainment to imagined rhythm during auditory imagery of beat and meter, we recorded EEG while nine participants (eight males and one female) imagined three types of rhythm without auditory stimuli but with visual timing, and then we analyzed the amplitude spectra of the EEG. We also recorded EEG while the participants only gazed at the visual timing as a control condition to confirm the visual effect. Furthermore, we derived features of the EEG using canonical correlation analysis (CCA) and conducted an experiment to individually classify the three types of imagined rhythm from the EEG. The results showed that classification accuracies exceeded the chance level in all participants. These results suggest that auditory imagery of meter elicits a periodic EEG response that changes at the imagined beat and meter frequency even in the fully imagined conditions. This study represents the first step toward the realization of a method for reconstructing the imagined music from brain activity.
Circular flow patterns induced by ciliary activity in reconstituted human bronchial epithelium
NASA Astrophysics Data System (ADS)
Viallat, Annie; Khelloufi, Kamel; Gras, Delphine; Chanez, Pascal; Aix Marseille Univ., CNRS, CINaM, Marseille, France Team; Aix Marseille Univ., CNRS, Inserm, LAI, Marseille, France Team
2016-11-01
Mucociliary clearance is the transport at the surface of airways of a complex fluid layer, the mucus, moved by the beats of microscopic cilia present on epithelial ciliated cells. We explored the coupling between the spatial organisation and the activity of cilia and the transport of surface fluids on reconstituted cultures of human bronchial epithelium at air-liquid interface, obtained by human biopsies. We reveal the existence of stable local circular surface flow patterns of mucus or Newtonian fluid at the epithelium surface. We find a power law over more than 3 orders of magnitude showing that the average ciliated cell density controls the size of these flow patterns, and, therefore the distance over which mucus can be transported. We show that these circular flow patterns result from the radial linear increase of the local propelling forces (due to ciliary beats) on each flow domain. This linear increase of local forces is induced by a fine self-regulation of both cilia density and orientation of ciliary beats. Local flow domains grow and merge during ciliogenesis to provide macroscopic mucus transport. This is possible only when the viscoelastic mucus continuously exerts a shear stress on beating cilia, revealing a mechanosensitive function of cilia. M. K. Khelloufi thanks the society MedBioMed for financial support. This work was supported by the ANR MUCOCIL project, Grant ANR-13-BSV5-0015 of the French Agence Nationale de la Recherche.
A microprocessor-based cardiotachometer
NASA Technical Reports Server (NTRS)
Donaldson, J. A.; Crosier, W. G.
1979-01-01
The development of a highly accurate and reliable cardiotachometer for measuring the heart rate of test subjects is discussed. It measures heart rate over the range of 30 to 250 beats/minute and gives instantaneous (beat to beat) updates on the system output so that occasional noise artifacts or ectopic beats could be more easily identified except that occasional missed beats caused by switching ECG leads should not cause a change in the output. The cardiotachometer uses an improved analog filter and R-wave detector and an Intel 8080A microprocessor to handle all of the logic and arithmetic necessary. By using the microprocessor, future hardware modifications could easily be made if functional changes were needed.
Choi, Seong Wook; Nam, Kyoung Won; Lim, Ki Moo; Shim, Eun Bo; Won, Yong Soon; Woo, Heung Myong; Kwak, Ho Hyun; Noh, Mi Ryoung; Kim, In Young; Park, Sung Min
2014-04-03
When using a pulsatile left ventricular assist device (LVAD), it is important to reduce the cardiac load variations of the native heart because severe cardiac load variations can induce ventricular arrhythmia. In this study, we investigated the effect of counter-pulsation control of the LVAD on the reduction of cardiac load variation. A ventricular electrocardiogram-based counter-pulsation control algorithm for a LVAD was implemented, and the effects of counter-pulsation control of the LVAD on the reduction of the working load variations of the left ventricle were determined in three animal experiments. Deviations of the working load of the left ventricle were reduced by 51.3%, 67.9%, and 71.5% in each case, and the beat-to-beat variation rates in the working load were reduced by 84.8%, 82.7%, and 88.2% in each ease after counter-pulsation control. There were 3 to 12 premature ventricle contractions (PVCs) before counter-pulsation control, but no PVCs were observed during counter-pulsation control. Counter-pulsation control of the pulsatile LVAD can reduce severe cardiac load variations, but the average working load is not markedly affected by application of counter-pulsation control because it is also influenced by temporary cardiac outflow variations. We believe that counter-pulsation control of the LVAD can improve the long-term safety of heart failure patients equipped with LVADs.
Rehabilitation R&D Progress Reports 1996, Volume 34, May 1997
1997-05-01
Arlington, VA 22230 PURPOSE!—Atrioventricular (AV) nodal alternans is a pathological cardiac condition characterized by a beat - to- beat alternation...regime where the AV nodal conduc- tion time alternated on a beat -to- beat basis. After using additive white noise to learn the dynamics of the underly... binaurally accord- ing to the NAL-R prescriptive formula. These groups will be followed over a period of 6 months and tested at monthly intervals. At each
A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen
NASA Astrophysics Data System (ADS)
Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu
2018-02-01
Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.
Transplantation of donor hearts after circulatory or brain death in a rat model.
Li, Shiliang; Loganathan, Sivakkanan; Korkmaz, Sevil; Radovits, Tamás; Hegedűs, Peter; Zhou, Yan; Karck, Matthias; Szabó, Gábor
2015-05-01
Heart transplantation represents the only curative treatment for end-stage heart failure. Presently, the donor pool is restricted to brain-dead donors. Based on the lack of suitable donors and the increasing number of patients, we investigated some molecular pathomechanisms of the potential use of hearts after circulatory determination of death (DCDD) in transplantation. Rats were either maintained brain death for 5 h by inflation of a subdurally placed balloon catheter (n = 6) or subjected to cardiac arrest by exsanguinations (n = 6). Additionally, a control group was used (n = 9). Then the hearts were perfused with a cold preservation solution (Custodiol), explanted, stored at 4°C in Custodiol, and heterotopically transplanted. Brain death was associated with decreased left-ventricular contractility (dP/dtmax: 4895 ± 505 versus 8037 ± 565 mm Hg/s; ejection fraction: 27 ± 5 versus 44 ± 5%; Emax: 2.2 ± 0.3 versus 4.2 ± 0.3 mm Hg/μL; preload recruitable stroke work: 59 ± 5 versus 96 ± 6 mm Hg; 5 h after brain death versus before brain death; P < 0.05) and impaired cardiac relaxation (dP/dtmin: -4734 ± 575 versus -9404 ± 550 mm Hg/s and prolonged Tau, P < 0.05) compared with controls. After transplantation, significantly decreased systolic function and prolonged Tau were observed in brain-dead and DCDD groups compared with those in controls. Tumor necrosis factor-alpha, cyclooxygenase-2, nuclear factor-κB, inducible-NOS, and caspase-3 messenger RNA and protein-levels were significantly increased in the brain-dead compared with both control and DCDD groups. Additionally, marked myocardial inflammatory cell infiltration, edema, necrosis, and DNA-strand breaks were observed in the brain-dead group. Our results show that despite the similar functional outcome in DCDD and brain-dead groups, brain-dead hearts showed marked myocardial inflammatory cell infiltration, edema, necrosis, DNA-strand breaks, and increased transcriptional and posttranscriptional expression for markers of apoptosis and inflammatory signaling pathways. Copyright © 2015 Elsevier Inc. All rights reserved.
Wife beating refusal among women of reproductive age in urban and rural Ethiopia.
Gurmu, Eshetu; Endale, Senait
2017-03-16
Wife beating is the most common and widespread form of intimate partner violence in Ethiopia. It results in countless severe health, socio-economic and psychological problems and has contributed to the violation of human rights including the liberty of women to enjoy conjugal life. The main purpose of this study is to assess the levels and patterns of wife beating refusal and its associated socio-cultural and demographic factors in rural and urban Ethiopia. The 2011 Ethiopian Demographic and Health Survey (EDHS) data based on 11,097 and 5287 women in the reproductive age group (i.e. 15-49 years) living in rural and urban areas, respectively,were used in this study. Cronbach's alpha was used to assess the internal consistency of the measure of women's attitudes towards wife beating. The Statistical Package for Social Sciences was applied to analyze the data. A binary logistic regression model was fitted to identify variables that significantly predict respondents' refusal of wife beating. Separate analysis by a place of residence was undertaken as attitude towards wife beating vary between rural and urban areas. The likelihood of refusing wife beating in Ethiopia was significantly higher among urban women (54.2%) than rural women (24.5%). Although there was a significant variations in attitude towards refusing wife beating among different regions in Ethiopia, increasing educational level, high access to media, age of respondents were associated with high level of refusal of wife beating. In contrast, rural residence, being in marital union, high number of living children, being followers of some religions (Muslim followers in urban and Protestants in rural) were associated with low level of refusal of wife beating. The findings of this study reveal that wife beating in Ethiopia is a function of demographic and socio-cultural factors among which age and educational attainment of respondents, number of living children, religious affiliation, marital commitment and region of residence play significant roles. As factors governing perceptions and behaviours of individuals and institutional settings appear to shape knowledge and attitude towards gender equity and equality, awareness creation and behavioural change initiatives should be considered to abolish violence against women.
American Idol's Randy Jackson He doesn't miss a beat controlling his diabetes
... Jackson is a well-known name in the music world. He has played bass guitar with such musical legends as jazz violinist Jean Luc Ponty, the pop-rock band Journey, and many others. And he's produced ...
Teratogenic efects of injected methylmercury on avian embryos
Heinz, Gary H.; Hoffman, David J.; Klimstra, Jon D.; Stebbins, Katherine R.; Kondrad, Shannon L.; Erwin, Carol A.
2011-01-01
Controlled laboratory studies with game farm mallards (Anas platyrhynchos) and chickens (Gallus gallus) have demonstrated that methylmercury can cause teratogenic effects in birds, but studies with wild species of birds are lacking. To address this need, doses of methylmercury chloride were injected into the eggs of 25 species of birds, and the dead embryos and hatched chicks were examined for external deformities. When data for controls were summed across all 25 species tested and across all types of deformities, 24 individuals out of a total of 1,533 (a rate of 1.57%) exhibited at least one deformity. In contrast, when data for all of the mercury treatments and all 25 species were summed, 188 deformed individuals out of a total of 2,292 (8.20%) were found. Some deformities, such as lordosis and scoliosis (twisting of the spine), misshapen heads, shortening or twisting of the neck, and deformities of the wings, were seldom observed in controls but occurred in much greater frequency in Hg-treated individuals. Only 0.59% of individual control dead embryos and hatchlings exhibited multiple deformities versus 3.18% for Hg-dosed dead embryos and hatchlings. Methylmercury seems to have a widespread teratogenic potential across many species of birds.
On-off nonlinear active control of floor vibrations
NASA Astrophysics Data System (ADS)
Díaz, Iván M.; Reynolds, Paul
2010-08-01
Human-induced floor vibrations can be mitigated by means of active control via an electromagnetic proof-mass actuator. Previous researchers have developed a system for floor vibration comprising linear velocity feedback control (LVFC) with a command limiter (saturation in the command signal to avoid actuator overloading). The performance of this control is highly dependent on the linear gain utilised, which has to be designed for a particular excitation and might not be optimum for other excitations. This work explores the use of on-off nonlinear velocity feedback control (NLVFC) as the natural evolution of LVFC when high gains and/or significant vibration level are present together with saturation in the control law. Firstly, the describing function tool is employed to analyse the stability properties of: (1) LVFC with saturation, (2) on-off NLVFC with a dead zone and (3) on-off NLVFC with a switching-off function. Particular emphasis is paid to the resulting limit cycle behaviour and the design of appropriate dead zone and switching-off levels to avoid it. Secondly, experimental trials using the three control laws are conducted on a laboratory test floor. The results corroborate the analytical stability predictions. The pros of on-off NLVFC are that no gain has to be chosen and maximum actuator energy is delivered to cancel the vibration. In contrast, the requirement to select a dead zone or switching-off function provides a drawback in its application.
Otani, Kyoko; Nakazono, Akemi; Salgo, Ivan S; Lang, Roberto M; Takeuchi, Masaaki
2016-10-01
Echocardiographic determination of left heart chamber volumetric parameters by using manual tracings during multiple beats is tedious in atrial fibrillation (AF). The aim of this study was to determine the usefulness of fully automated left chamber quantification software with single-beat three-dimensional transthoracic echocardiographic data sets in patients with AF. Single-beat full-volume three-dimensional transthoracic echocardiographic data sets were prospectively acquired during consecutive multiple cardiac beats (≥10 beats) in 88 patients with AF. In protocol 1, left ventricular volumes, left ventricular ejection fraction, and maximal left atrial volume were validated using automated quantification against the manual tracing method in identical beats in 10 patients. In protocol 2, automated quantification-derived averaged values from multiple beats were compared with the corresponding values obtained from the indexed beat in all patients. Excellent correlations of left chamber parameters between automated quantification and the manual method were observed (r = 0.88-0.98) in protocol 1. The time required for the analysis with the automated quantification method (5 min) was significantly less compared with the manual method (27 min) (P < .0001). In protocol 2, there were excellent linear correlations between the averaged left chamber parameters and the corresponding values obtained from the indexed beat (r = 0.94-0.99), and test-retest variability of left chamber parameters was low (3.5%-4.8%). Three-dimensional transthoracic echocardiography with fully automated quantification software is a rapid and reliable way to measure averaged values of left heart chamber parameters during multiple consecutive beats. Thus, it is a potential new approach for left chamber quantification in patients with AF in daily routine practice. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Beat gestures improve word recall in 3- to 5-year-old children.
Igualada, Alfonso; Esteve-Gibert, Núria; Prieto, Pilar
2017-04-01
Although research has shown that adults can benefit from the presence of beat gestures in word recall tasks, studies have failed to conclusively generalize these findings to preschool children. This study investigated whether the presence of beat gestures helps children to recall information when these gestures have the function of singling out a linguistic element in its discourse context. A total of 106 3- to 5-year-old children were asked to recall a list of words within a pragmatically child-relevant context (i.e., a storytelling activity) in which the target word was or was not accompanied by a beat gesture. Results showed that children recalled the target word significantly better when it was accompanied by a beat gesture than when it was not, indicating a local recall effect. Moreover, the recall of adjacent non-target words did not differ depending on the condition, revealing that beat gestures seem to have a strictly local highlighting function (i.e., no global recall effect). These results demonstrate that preschoolers benefit from the pragmatic contribution offered by beat gestures when they function as multimodal markers of prominence. Copyright © 2016 Elsevier Inc. All rights reserved.
How molecular motors shape the flagellar beat
Riedel-Kruse, Ingmar H.; Hilfinger, Andreas; Howard, Jonathon; Jülicher, Frank
2007-01-01
Cilia and eukaryotic flagella are slender cellular appendages whose regular beating propels cells and microorganisms through aqueous media. The beat is an oscillating pattern of propagating bends generated by dynein motor proteins. A key open question is how the activity of the motors is coordinated in space and time. To elucidate the nature of this coordination we inferred the mechanical properties of the motors by analyzing the shape of beating sperm: Steadily beating bull sperm were imaged and their shapes were measured with high precision using a Fourier averaging technique. Comparing our experimental data with wave forms calculated for different scenarios of motor coordination we found that only the scenario of interdoublet sliding regulating motor activity gives rise to satisfactory fits. We propose that the microscopic origin of such “sliding control” is the load dependent detachment rate of motors. Agreement between observed and calculated wave forms was obtained only if significant sliding between microtubules occurred at the base. This suggests a novel mechanism by which changes in basal compliance could reverse the direction of beat propagation. We conclude that the flagellar beat patterns are determined by an interplay of the basal properties of the axoneme and the mechanical feedback of dynein motors. PMID:19404446
Deep learning based beat event detection in action movie franchises
NASA Astrophysics Data System (ADS)
Ejaz, N.; Khan, U. A.; Martínez-del-Amor, M. A.; Sparenberg, H.
2018-04-01
Automatic understanding and interpretation of movies can be used in a variety of ways to semantically manage the massive volumes of movies data. "Action Movie Franchises" dataset is a collection of twenty Hollywood action movies from five famous franchises with ground truth annotations at shot and beat level of each movie. In this dataset, the annotations are provided for eleven semantic beat categories. In this work, we propose a deep learning based method to classify shots and beat-events on this dataset. The training dataset for each of the eleven beat categories is developed and then a Convolution Neural Network is trained. After finding the shot boundaries, key frames are extracted for each shot and then three classification labels are assigned to each key frame. The classification labels for each of the key frames in a particular shot are then used to assign a unique label to each shot. A simple sliding window based method is then used to group adjacent shots having the same label in order to find a particular beat event. The results of beat event classification are presented based on criteria of precision, recall, and F-measure. The results are compared with the existing technique and significant improvements are recorded.
Du, Wei-Guo; Radder, Rajkumar S; Sun, Bo; Shine, Richard
2009-05-01
The eggs of birds typically hatch after a fixed (but lineage-specific) cumulative number of heart beats since the initiation of incubation. Is the same true for non-avian reptiles, despite wide intraspecific variation in incubation period generated by variable nest temperatures? Non-invasive monitoring of embryo heart beat rates in one turtle species (Pelodiscus sinensis) and two lizards (Bassiana duperreyi and Takydromus septentrionalis) show that the total number of heart beats during embryogenesis is relatively constant over a wide range of warm incubation conditions. However, incubation at low temperatures increases the total number of heart beats required to complete embryogenesis, because the embryo spends much of its time at temperatures that require maintenance functions but that do not allow embryonic growth or differentiation. Thus, cool-incubated embryos allocate additional metabolic effort to maintenance costs. Under warm conditions, total number of heart beats thus predicts incubation period in non-avian reptiles as well as in birds (the total number of heart beats are also similar); however, under the colder nest conditions often experienced by non-avian reptiles, maintenance costs add significantly to total embryonic metabolic expenditure.
Neural responses to sounds presented on and off the beat of ecologically valid music
Tierney, Adam; Kraus, Nina
2013-01-01
The tracking of rhythmic structure is a vital component of speech and music perception. It is known that sequences of identical sounds can give rise to the percept of alternating strong and weak sounds, and that this percept is linked to enhanced cortical and oscillatory responses. The neural correlates of the perception of rhythm elicited by ecologically valid, complex stimuli, however, remain unexplored. Here we report the effects of a stimulus' alignment with the beat on the brain's processing of sound. Human subjects listened to short popular music pieces while simultaneously hearing a target sound. Cortical and brainstem electrophysiological onset responses to the sound were enhanced when it was presented on the beat of the music, as opposed to shifted away from it. Moreover, the size of the effect of alignment with the beat on the cortical response correlated strongly with the ability to tap to a beat, suggesting that the ability to synchronize to the beat of simple isochronous stimuli and the ability to track the beat of complex, ecologically valid stimuli may rely on overlapping neural resources. These results suggest that the perception of musical rhythm may have robust effects on processing throughout the auditory system. PMID:23717268
Farrow, Darcie A; Smith, Eric R; Qian, Wei; Jonas, David M
2008-11-07
By analogy to the Raman depolarization ratio, vibrational quantum beats in pump-probe experiments depend on the relative pump and probe laser beam polarizations in a way that reflects vibrational symmetry. The polarization signatures differ from those in spontaneous Raman scattering because the order of field-matter interactions is different. Since pump-probe experiments are sensitive to vibrations on excited electronic states, the polarization anisotropy of vibrational quantum beats can also reflect electronic relaxation processes. Diagrammatic treatments, which expand use of the symmetry of the two-photon tensor to treat signal pathways with vibrational and vibronic coherences, are applied to find the polarization anisotropy of vibrational and vibronic quantum beats in pump-probe experiments for different stages of electronic relaxation in square symmetric molecules. Asymmetric vibrational quantum beats can be distinguished from asymmetric vibronic quantum beats by a pi phase jump near the center of the electronic spectrum and their disappearance in the impulsive limit. Beyond identification of vibrational symmetry, the vibrational quantum beat anisotropy can be used to determine if components of a doubly degenerate electronic state are unrelaxed, dephased, population exchanged, or completely equilibrated.
Deterioration of wood from live and dead Alaska yellow-cedar in contact with soil
Paul Hennon; Bessie Woodward; Patricia Lebow
2007-01-01
The deterioration of heartwood from live and dead Alaska yellow-cedar trees was evaluated by exposing ministakes in soils at field sites in Alaska and Mississippi for 2 and 4 year intervals. Southern yellow pine sapwood served as a control. The vastly greater deterioration, as measured by weight loss, in Mississippi compared to Alaska (60 and 10 percent after 4 years,...
Functional significance of cardiac reinnervation in heart transplant recipients.
Schwaiblmair, M; von Scheidt, W; Uberfuhr, P; Ziegler, S; Schwaiger, M; Reichart, B; Vogelmeier, C
1999-09-01
There is accumulating evidence of structural sympathetic reinnervation after human cardiac transplantation. However, the functional significance of reinnervation in terms of exercise capacity has not been established as yet; we therefore investigated the influence of reinnervation on cardiopulmonary exercise testing. After orthotopic heart transplantation 35 patients (mean age, 49.1 +/- 8.4 years) underwent positron emission tomography with scintigraphically measured uptake of C11-hydroxyephedrine (HED), lung function testing, and cardiopulmonary exercise testing. Two groups were defined based on scintigraphic findings, indicating a denervated group (n = 15) with a HED uptake of 5.45%/min and a reinnervated group (n = 20) with a HED uptake of 10.59%/min. The two study groups did not show significant differences with regard to anthropometric data, number of rejection episodes, preoperative hemodynamics, and postoperative lung function data. The reinnervated group had a significant longer time interval from transplantation (1625 +/- 1069 versus 800 +/- 1316 days, p < .05). In transplant recipients with reinnervation, heart rate at maximum exercise (137 +/- 15 versus 120 +/- 20 beats/min, p = .012), peak oxygen uptake (21.0 +/- 4 versus 16.1 +/- 5 mL/min/kg, p = .006), peak oxygen pulse (12.4 +/- 2.9 versus 10.2 +/- 2.7 mL/min/beat, p = .031), and anaerobic threshold (11.2 +/- 1.8 versus 9.5 +/- 2.1 mL/min, p = .046) were significantly increased in comparison to denervated transplant recipients. Additionally, a decreased functional dead space ventilation (0.24 +/- 0.05 versus 0.30 +/- 0.05, p = .004) was observed in the reinnervated group. Our study results support the hypothesis that partial sympathetic reinnervation after cardiac transplantation is of functional significance. Sympathetic reinnervation enables an increased peak oxygen uptake. This is most probably due to partial restoration of the chronotropic and inotropic competence of the heart as well as an improved oxygen delivery to the exercising muscles and a reduced ventilation-perfusion mismatching.
Tong, Shaocheng; Wang, Tong; Li, Yongming; Zhang, Huaguang
2014-06-01
This paper discusses the problem of adaptive neural network output feedback control for a class of stochastic nonlinear strict-feedback systems. The concerned systems have certain characteristics, such as unknown nonlinear uncertainties, unknown dead-zones, unmodeled dynamics and without the direct measurements of state variables. In this paper, the neural networks (NNs) are employed to approximate the unknown nonlinear uncertainties, and then by representing the dead-zone as a time-varying system with a bounded disturbance. An NN state observer is designed to estimate the unmeasured states. Based on both backstepping design technique and a stochastic small-gain theorem, a robust adaptive NN output feedback control scheme is developed. It is proved that all the variables involved in the closed-loop system are input-state-practically stable in probability, and also have robustness to the unmodeled dynamics. Meanwhile, the observer errors and the output of the system can be regulated to a small neighborhood of the origin by selecting appropriate design parameters. Simulation examples are also provided to illustrate the effectiveness of the proposed approach.
Shi, Wuxi; Luo, Rui; Li, Baoquan
2017-01-01
In this study, an adaptive fuzzy prescribed performance control approach is developed for a class of uncertain multi-input and multi-output (MIMO) nonlinear systems with unknown control direction and unknown dead-zone inputs. The properties of symmetric matrix are exploited to design adaptive fuzzy prescribed performance controller, and a Nussbaum-type function is incorporated in the controller to estimate the unknown control direction. This method has two prominent advantages: it does not require the priori knowledge of control direction and only three parameters need to be updated on-line for this MIMO systems. It is proved that all the signals in the resulting closed-loop system are bounded and that the tracking errors converge to a small residual set with the prescribed performance bounds. The effectiveness of the proposed approach is validated by simulation results. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Kuwada, S; Yin, T C; Wickesberg, R E
1979-11-02
The interaural phase sensitivity of neurons was studied through the use of binaural beat stimuli. The response of most cells was phase-locked to the beat frequency, which provides a possible neural correlate to the human sensation of binaural beats. In addition, this stimulus allowed the direction and rate of interaural phase change to be varied. Some neurons in our sample responded selectively to manipulations of these two variables, which suggests a sensitivity to direction or speed of movement.
Floré, Vincent; Willems, Rik
2012-12-01
In this review, we focus on temporal variability of cardiac repolarization. This phenomenon has been related to a higher risk for ventricular arrhythmia and is therefore interesting as a marker of sudden cardiac death risk. We review two non-invasive clinical techniques quantifying repolarization variability: T-wave alternans (TWA) and beat-to-beat variability of repolarization (BVR). We discuss their pathophysiological link with ventricular arrhythmia and the current clinical relevance of these techniques.
Digital computing cardiotachometer
NASA Technical Reports Server (NTRS)
Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)
1973-01-01
A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.
Pangerc, Urška; Jager, Franc
2015-08-01
In this work, we present the development, architecture and evaluation of a new and robust heart beat detector in multimodal records. The detector uses electrocardiogram (ECG) signals, and/or pulsatile (P) signals, such as: blood pressure, artery blood pressure and pulmonary artery pressure, if present. The base approach behind the architecture of the detector is collecting signal energy (differentiating and low-pass filtering, squaring, integrating). To calculate the detection and noise functions, simple and fast slope- and peak-sensitive band-pass digital filters were designed. By using morphological smoothing, the detection functions were further improved and noise intervals were estimated. The detector looks for possible pacemaker heart rate patterns and repairs the ECG signals and detection functions. Heart beats are detected in each of the ECG and P signals in two steps: a repetitive learning phase and a follow-up detecting phase. The detected heart beat positions from the ECG signals are merged into a single stream of detected ECG heart beat positions. The merged ECG heart beat positions and detected heart beat positions from the P signals are verified for their regularity regarding the expected heart rate. The detected heart beat positions of a P signal with the best match to the merged ECG heart beat positions are selected for mapping into the noise and no-signal intervals of the record. The overall evaluation scores in terms of average sensitivity and positive predictive values obtained on databases that are freely available on the Physionet website were as follows: the MIT-BIH Arrhythmia database (99.91%), the MGH/MF Waveform database (95.14%), the augmented training set of the follow-up phase of the PhysioNet/Computing in Cardiology Challenge 2014 (97.67%), and the Challenge test set (93.64%).
Finding the beat: a neural perspective across humans and non-human primates.
Merchant, Hugo; Grahn, Jessica; Trainor, Laurel; Rohrmeier, Martin; Fitch, W Tecumseh
2015-03-19
Humans possess an ability to perceive and synchronize movements to the beat in music ('beat perception and synchronization'), and recent neuroscientific data have offered new insights into this beat-finding capacity at multiple neural levels. Here, we review and compare behavioural and neural data on temporal and sequential processing during beat perception and entrainment tasks in macaques (including direct neural recording and local field potential (LFP)) and humans (including fMRI, EEG and MEG). These abilities rest upon a distributed set of circuits that include the motor cortico-basal-ganglia-thalamo-cortical (mCBGT) circuit, where the supplementary motor cortex (SMA) and the putamen are critical cortical and subcortical nodes, respectively. In addition, a cortical loop between motor and auditory areas, connected through delta and beta oscillatory activity, is deeply involved in these behaviours, with motor regions providing the predictive timing needed for the perception of, and entrainment to, musical rhythms. The neural discharge rate and the LFP oscillatory activity in the gamma- and beta-bands in the putamen and SMA of monkeys are tuned to the duration of intervals produced during a beat synchronization-continuation task (SCT). Hence, the tempo during beat synchronization is represented by different interval-tuned cells that are activated depending on the produced interval. In addition, cells in these areas are tuned to the serial-order elements of the SCT. Thus, the underpinnings of beat synchronization are intrinsically linked to the dynamics of cell populations tuned for duration and serial order throughout the mCBGT. We suggest that a cross-species comparison of behaviours and the neural circuits supporting them sets the stage for a new generation of neurally grounded computational models for beat perception and synchronization. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Finding the beat: a neural perspective across humans and non-human primates
Merchant, Hugo; Grahn, Jessica; Trainor, Laurel; Rohrmeier, Martin; Fitch, W. Tecumseh
2015-01-01
Humans possess an ability to perceive and synchronize movements to the beat in music (‘beat perception and synchronization’), and recent neuroscientific data have offered new insights into this beat-finding capacity at multiple neural levels. Here, we review and compare behavioural and neural data on temporal and sequential processing during beat perception and entrainment tasks in macaques (including direct neural recording and local field potential (LFP)) and humans (including fMRI, EEG and MEG). These abilities rest upon a distributed set of circuits that include the motor cortico-basal-ganglia–thalamo-cortical (mCBGT) circuit, where the supplementary motor cortex (SMA) and the putamen are critical cortical and subcortical nodes, respectively. In addition, a cortical loop between motor and auditory areas, connected through delta and beta oscillatory activity, is deeply involved in these behaviours, with motor regions providing the predictive timing needed for the perception of, and entrainment to, musical rhythms. The neural discharge rate and the LFP oscillatory activity in the gamma- and beta-bands in the putamen and SMA of monkeys are tuned to the duration of intervals produced during a beat synchronization–continuation task (SCT). Hence, the tempo during beat synchronization is represented by different interval-tuned cells that are activated depending on the produced interval. In addition, cells in these areas are tuned to the serial-order elements of the SCT. Thus, the underpinnings of beat synchronization are intrinsically linked to the dynamics of cell populations tuned for duration and serial order throughout the mCBGT. We suggest that a cross-species comparison of behaviours and the neural circuits supporting them sets the stage for a new generation of neurally grounded computational models for beat perception and synchronization. PMID:25646516
Mismatch negativity to acoustical illusion of beat: how and where the change detection takes place?
Chakalov, Ivan; Paraskevopoulos, Evangelos; Wollbrink, Andreas; Pantev, Christo
2014-10-15
In case of binaural presentation of two tones with slightly different frequencies the structures of brainstem can no longer follow the interaural time differences (ITD) resulting in an illusionary perception of beat corresponding to frequency difference between the two prime tones. Hence, the beat-frequency does not exist in the prime tones presented to either ear. This study used binaural beats to explore the nature of acoustic deviance detection in humans by means of magnetoencephalography (MEG). Recent research suggests that the auditory change detection is a multistage process. To test this, we employed 26 Hz-binaural beats in a classical oddball paradigm. However, the prime tones (250 Hz and 276 Hz) were switched between the ears in the case of the deviant-beat. Consequently, when the deviant is presented, the cochleae and auditory nerves receive a "new afferent", although the standards and the deviants are heard identical (26 Hz-beats). This allowed us to explore the contribution of auditory periphery to change detection process, and furthermore, to evaluate its influence on beats-related auditory steady-state responses (ASSRs). LORETA-source current density estimates of the evoked fields in a typical mismatch negativity time-window (MMN) and the subsequent difference-ASSRs were determined and compared. The results revealed an MMN generated by a complex neural network including the right parietal lobe and the left middle frontal gyrus. Furthermore, difference-ASSR was generated in the paracentral gyrus. Additionally, psychophysical measures showed no perceptual difference between the standard- and deviant-beats when isolated by noise. These results suggest that the auditory periphery has an important contribution to novelty detection already at sub-cortical level. Overall, the present findings support the notion of hierarchically organized acoustic novelty detection system. Copyright © 2014 Elsevier Inc. All rights reserved.
A quantitative electroencephalographic study of meditation and binaural beat entrainment.
Lavallee, Christina F; Koren, Stanley A; Persinger, Michael A
2011-04-01
The study objective was to determine the quantitative electroencephalographic correlates of meditation, as well as the effects of hindering (15 Hz) and facilitative (7 Hz) binaural beats on the meditative process. The study was a mixed design, with experience of the subject as the primary between-subject measure and power of the six classic frequency bands (δ, θ, low α, high α, β, γ), neocortical lobe (frontal, temporal, parietal, occipital), hemisphere (left, right), and condition (meditation only, meditation with 7-Hz beats, meditation with 15-Hz beats) as the within-subject measures. The study was conducted at Laurentian University in Sudbury, Ontario, Canada. The subjects comprised novice (mean of 8 months experience) and experienced (mean of 18 years experience) meditators recruited from local meditation groups. Experimental manipulation included application of hindering and facilitative binaural beats to the meditative process. Experienced meditators displayed increased left temporal lobe δ power when the facilitative binaural beats were applied, whereas the effect was not observed for the novice subjects in this condition. When the hindering binaural beats were introduced, the novice subjects consistently displayed more γ power than the experienced subjects over the course of their meditation, relative to baseline. Based on the results of this study, novice meditators were not able to maintain certain levels of θ power in the occipital regions when hindering binaural beats were presented, whereas when the facilitative binaural beats were presented, the experienced meditators displayed increased θ power in the left temporal lobe. These results suggest that the experienced meditators have developed techniques over the course of their meditation practice to counter hindering environmental stimuli, whereas the novice meditators have not yet developed those techniques.
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.
Jafari Tadi, Mojtaba; Lehtonen, Eero; Hurnanen, Tero; Koskinen, Juho; Eriksson, Jonas; Pänkäälä, Mikko; Teräs, Mika; Koivisto, Tero
2016-11-01
Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart. Measuring true beat-to-beat time intervals from SCG could be used for monitoring of the heart rhythm, for heart rate variability analysis and for many other clinical applications. In this paper we present the Hilbert adaptive beat identification technique for the detection of heartbeat timings and inter-beat time intervals in SCG from healthy volunteers in three different positions, i.e. supine, left and right recumbent. Our method is electrocardiogram (ECG) independent, as it does not require any ECG fiducial points to estimate the beat-to-beat intervals. The performance of the algorithm was tested against standard ECG measurements. The average true positive rate, positive prediction value and detection error rate for the different positions were, respectively, supine (95.8%, 96.0% and ≃0.6%), left (99.3%, 98.8% and ≃0.001%) and right (99.53%, 99.3% and ≃0.01%). High correlation and agreement was observed between SCG and ECG inter-beat intervals (r > 0.99) for all positions, which highlights the capability of the algorithm for SCG heart monitoring from different positions. Additionally, we demonstrate the applicability of the proposed method in smartphone based SCG. In conclusion, the proposed algorithm can be used for real-time continuous unobtrusive cardiac monitoring, smartphone cardiography, and in wearable devices aimed at health and well-being applications.
Intertrial auditory neural stability supports beat synchronization in preschoolers
Carr, Kali Woodruff; Tierney, Adam; White-Schwoch, Travis; Kraus, Nina
2016-01-01
The ability to synchronize motor movements along with an auditory beat places stringent demands on the temporal processing and sensorimotor integration capabilities of the nervous system. Links between millisecond-level precision of auditory processing and the consistency of sensorimotor beat synchronization implicate fine auditory neural timing as a mechanism for forming stable internal representations of, and behavioral reactions to, sound. Here, for the first time, we demonstrate a systematic relationship between consistency of beat synchronization and trial-by-trial stability of subcortical speech processing in preschoolers (ages 3 and 4 years old). We conclude that beat synchronization might provide a useful window into millisecond-level neural precision for encoding sound in early childhood, when speech processing is especially important for language acquisition and development. PMID:26760457
Sung, C L; Cheng, H P; Lee, C Y; Cho, C Y; Liang, H C; Chen, Y F
2016-04-15
The simultaneous self-mode-locking of two orthogonally polarized states in a Nd:YAG laser is demonstrated by using a short linear cavity. A total output power of 3.8 W can be obtained at an incident pump power of 8.2 W. The beat frequency Δfc between two orthogonally polarized mode-locked components is observed and measured precisely. It is found that the beat frequency increases linearly with an increase in the absorbed pump power. The origin of the beat frequency can be utterly manifested by considering the thermally induced birefringence in the Nd:YAG crystal. The present result offers a promising approach to generate orthogonally polarized mode-locked lasers with tunable beat frequency.
Prostaglandins are important in thermoregulation of a reptile (Pogona vitticeps).
Seebacher, Frank; Franklin, Craig E
2003-01-01
The effectiveness of behavioural thermoregulation in reptiles is amplified by cardiovascular responses, particularly by differential rates of heart beat in response to heating and cooling (heart-rate hysteresis). Heart-rate hysteresis is ecologically important in most lineages of ectothermic reptile, and we demonstrate that heart-rate hysteresis in the lizard Pogona vitticeps is mediated by prostaglandins. In a control treatment (administration of saline), heart rates during heating were significantly faster than during cooling at any given body temperature. When cyclooxygenase 1 and 2 enzymes were inhibited, heart rates during heating were not significantly different from those during cooling. Administration of agonists showed that thromboxane B(2) did not have a significant effect on heart rate, but prostacyclin and prostaglandin F(2alpha) caused a significant increase (3.5 and 13.6 beats min(-1), respectively) in heart rate compared with control treatments. We speculate that heart-rate hysteresis evolved as a thermoregulatory mechanism that may ultimately be controlled by neurally induced stimulation of nitric oxide production, or maybe via photolytically induced production of vitamin D. PMID:12952634
Prostaglandins are important in thermoregulation of a reptile (Pogona vitticeps).
Seebacher, Frank; Franklin, Craig E
2003-08-07
The effectiveness of behavioural thermoregulation in reptiles is amplified by cardiovascular responses, particularly by differential rates of heart beat in response to heating and cooling (heart-rate hysteresis). Heart-rate hysteresis is ecologically important in most lineages of ectothermic reptile, and we demonstrate that heart-rate hysteresis in the lizard Pogona vitticeps is mediated by prostaglandins. In a control treatment (administration of saline), heart rates during heating were significantly faster than during cooling at any given body temperature. When cyclooxygenase 1 and 2 enzymes were inhibited, heart rates during heating were not significantly different from those during cooling. Administration of agonists showed that thromboxane B(2) did not have a significant effect on heart rate, but prostacyclin and prostaglandin F(2alpha) caused a significant increase (3.5 and 13.6 beats min(-1), respectively) in heart rate compared with control treatments. We speculate that heart-rate hysteresis evolved as a thermoregulatory mechanism that may ultimately be controlled by neurally induced stimulation of nitric oxide production, or maybe via photolytically induced production of vitamin D.
Chaudhari, Umesh; Nemade, Harshal; Sureshkumar, Poornima; Vinken, Mathieu; Ates, Gamze; Rogiers, Vera; Hescheler, Jürgen; Hengstler, Jan Georg; Sachinidis, Agapios
2018-01-01
There is a large demand of a human relevant in vitro test system suitable for assessing the cardiotoxic potential of cosmetic ingredients and other chemicals. Using human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), we have already established an in vitro cardiotoxicity assay and identified genomic biomarkers of anthracycline-induced cardiotoxicity in our previous work. Here, five cosmetic ingredients were studied by the new hiPSC-CMs test; kojic acid (KJA), triclosan (TS), triclocarban (TCC), 2,7-naphthalenediol (NPT), and basic red 51 (BR51) based on cytotoxicity as well as ATP assays, beating rate, and genomic biomarkers to determine the lowest observed effect concentration (LOEC) and no observed effect concentration (NOEC). The LOEC for beating rate were 400, 10, 3, >400, and 3 µM for KJA, TS, TCC, NPT, and BR51, respectively. The corresponding concentrations for cytotoxicity or ATP depletion were similar, with the exception of TS and TCC, where the cardiomyocyte-beating assay showed positive results at non-cytotoxic concentrations. Functional analysis also showed that the individual compounds caused different effects on hiPSC-CMs. While exposure to KJA, TS, TCC, and BR51 induced significant arrhythmic beating, NPT slightly decreased cell viability, but did not influence beating. Gene expression studies showed that TS and NPT caused down-regulation of cytoskeletal and cardiac ion homeostasis genes. Moreover, TS and NPT deregulated genomic biomarkers known to be affected also by anthracyclines. The present study demonstrates that hiPSC-CMs can be used to determine LOECs and NOECs in vitro, which can be compared to human blood concentrations to determine margins of exposure. Our in vitro assay, which so far has been tested with several anthracyclines and cosmetics, still requires validation by larger numbers of positive and negative controls, before it can be recommended for routine analysis.
Benefits of copper recognised worldwide.
2014-09-01
In an article that first appeared in the June 2014 issue of Health Estate Journal's sister publication, The Clinical Services Journal, the Copper Development Association highlights the growing recognition, both in the UK, and among healthcare research and provider bodies overseas, of the significant part that antimicrobial copper can play in preventing and controlling infection in healthcare settings. Over the past few months, the Association explains, antimicrobial copper's infection-beating properties have been acknowledged by a variety of 'research and horizon-scanning' bodies, among them one in Canada, as well as by a leading UK consultancy and research provider to the NHS. The material is also increasingly being specified by hospitals worldwide following trials which have demonstrated clearly its efficacy in 'beating the bugs'.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Yanpeng; Department of Electronic Science and Technology, Xi'an Jiaotong University, Xi'an 710049; Gan Chenli
2006-05-15
We investigate the color-locked twin-noisy-field correlation effects in third-order nonlinear absorption and dispersion of ultrafast polarization beats. We demonstrate a phase-sensitive method for studying the two-photon nondegenerate four-wave mixing (NDFWM) due to atomic coherence in a multilevel system. The reference signal is another one-photon degenerate four-wave-mixing signal, which propagates along the same optical path as the NDFWM signal. This method is used for studying the phase dispersion of the third-order susceptibility and for the optical heterodyne detection of the NDFWM signal. The third-order nonlinear response can be controlled and modified through the color-locked correlation of twin noisy fields.
PWM Switching Frequency Effects on Eddy Current Sensors for Magnetically Suspended Flywheel Systems
NASA Technical Reports Server (NTRS)
Jansen, Ralph; Lebron, Ramon; Dever, Timothy P.; Birchenough, Arthur G.
2003-01-01
A flywheel magnetic bearing (MB) pulse width modulated power amplifier (PWM) configuration is selected to minimize noise generated by the PWMs in the flywheel position sensor system. Two types of noise are addressed: beat frequency noise caused by variations in PWM switching frequencies, and demodulation noise caused by demodulation of high order harmonics of the switching voltage into the MB control band. Beat frequency noise is eliminated by synchronizing the PWM switch frequencies, and demodulation noise is minimized by selection of a switching frequency which does not have harmonics at the carrier frequency of the sensor. The recommended MB PWM system has five synchronized PWMs switching at a non-integer harmonic of the sensor carrier.
Flagellar Kinematics and Swimming of Algal Cells in Viscoelastic Fluids
Qin, B.; Gopinath, A.; Yang, J.; Gollub, J. P.; Arratia, P. E.
2015-01-01
The motility of microorganisms is influenced greatly by their hydrodynamic interactions with the fluidic environment they inhabit. We show by direct experimental observation of the bi-flagellated alga Chlamydomonas reinhardtii that fluid elasticity and viscosity strongly influence the beating pattern - the gait - and thereby control the propulsion speed. The beating frequency and the wave speed characterizing the cyclical bending are both enhanced by fluid elasticity. Despite these enhancements, the net swimming speed of the alga is hindered for fluids that are sufficiently elastic. The origin of this complex response lies in the interplay between the elasticity-induced changes in the spatial and temporal aspects of the flagellar cycle and the buildup and subsequent relaxation of elastic stresses during the power and recovery strokes. PMID:25778677
Zhu, Ying; Dalal, Koustuv
2010-03-01
This study examined men's justification of wife beating in relation to their perceived rights and autonomy using a nationally representative sample of 18,047 men in India with childhood exposure to parental violence. Five reasons for wife beating justification, four items of men's perceived rights, and five items of household autonomy were analysed using chi2 test and logistic regression. Among 18,047 participants, 67% justified wife beating. Low education, economic stress and being unmarried were generally more associated with justifying wife beating for all five reasons. Wife's refusal of sex and husband's final say on household autonomy are risk factors. Joint autonomy on household decision making and wife's autonomy on managing her own earnings are protective factors. Perceived relationship rights and autonomy are highly predictive of wife-beating justification for the men who have been exposed to parental violence during childhood. The study has significant implications for public health planners and education strategies.
Theory of the development of alternans in the heart during controlled diastolic interval pacing
NASA Astrophysics Data System (ADS)
Otani, Niels F.
2017-09-01
The beat-to-beat alternation in action potential durations (APDs) in the heart, called APD alternans, has been linked to the development of serious cardiac rhythm disorders, including ventricular tachycardia and fibrillation. The length of the period between action potentials, called the diastolic interval (DI), is a key dynamical variable in the standard theory of alternans development. Thus, methods that control the DI may be useful in preventing dangerous cardiac rhythms. In this study, we examine the dynamics of alternans during controlled-DI pacing using a series of single-cell and one-dimensional (1D) fiber models of alternans dynamics. We find that a model that combines a so-called memory model with a calcium cycling model can reasonably explain two key experimental results: the possibility of alternans during constant-DI pacing and the phase lag of APDs behind DIs during sinusoidal-DI pacing. We also find that these results can be replicated by incorporating the memory model into an amplitude equation description of a 1D fiber. The 1D fiber result is potentially concerning because it seems to suggest that constant-DI control of alternans can only be effective over only a limited region in space.
Central control of cardiorespiratory interactions in fish.
Taylor, Edwin W; Leite, Cleo A C; Levings, Jennifer J
2009-01-01
Fish control the relative flow rates of water and blood over the gills in order to optimise respiratory gas exchange. As both flows are markedly pulsatile, close beat-to-beat relationships can be predicted. Cardiorespiratory interactions in fish are controlled primarily by activity in the parasympathetic nervous system that has its origin in cardiac vagal preganglionic neurons. Recordings of efferent activity in the cardiac vagus include units firing in respiration-related bursts. Bursts of electrical stimuli delivered peripherally to the cardiac vagus or centrally to respiratory branches of cranial nerves can recruit the heart over a range of frequencies. So, phasic, efferent activity in cardiac vagi, that in the intact fish are respiration-related, can cause heart rate to be modulated by the respiratory rhythm. In elasmobranch fishes this phasic activity seems to arise primarily from central feed-forward interactions with respiratory motor neurones that have overlapping distributions with cardiac neurons in the brainstem. In teleost fish, they arise from increased levels of efferent vagal activity arising from reflex stimulation of chemoreceptors and mechanoreceptors in the orobranchial cavity. However, these differences are largely a matter of emphasis as both groups show elements of feed-forward and feed-back control of cardiorespiratory interactions.
Understanding women's attitudes towards wife beating in Zimbabwe.
Hindin, Michelle J.
2003-01-01
OBJECTIVE: To investigate the factors associated with attitudes towards wife beating among women in partnerships in Zimbabwe in order to assist public health practitioners in preventing intimate partner violence (IPV). METHODS: A nationally representative survey of 5907 women of reproductive age (15-49 years) was conducted in Zimbabwe. Women were asked about their attitudes towards wife beating in five situations. The survey included sociodemographic characteristics, partnership characteristics, and household decision-making. FINDINGS: Over half of all women in Zimbabwe (53%) believed that wife beating was justified in at least one of the five situations. Respondents were most likely to find wife beating justified if a wife argued with her spouse (36%), neglected her children (33%), or went out without telling her spouse (30%). Among women in partnerships (n=3077), younger age, living in rural areas, lower household wealth, schooling at a lower level than secondary, and lower occupational status were associated with women reporting that wife beating is justified. Women who reported that they make household decisions jointly with their partners were less likely to say that wife beating is justified. CONCLUSIONS: Zimbabwe has a long way to go in preventing IPV, particularly because the younger generation of women is significantly more likely to believe that wife beating is justified compared with older women. Given the current social and political climate in Zimbabwe, finding means to negotiate rather than settle conflict through violence is essential from the household level to the national level. PMID:12973642
New insights into differential baroreflex control of heart rate in humans
NASA Technical Reports Server (NTRS)
Fadel, P. J.; Stromstad, M.; Wray, D. W.; Smith, S. A.; Raven, P. B.; Secher, N. H.
2003-01-01
Recent data indicate that bilateral carotid sinus denervation in patients results in a chronic impairment in the rapid reflex control of blood pressure during orthostasis. These findings are inconsistent with previous human experimental investigations indicating a minimal role for the carotid baroreceptor-cardiac reflex in blood pressure control. Therefore, we reexamined arterial baroreflex [carotid (CBR) and aortic baroreflex (ABR)] control of heart rate (HR) using newly developed methodologies. In 10 healthy men, 27 +/- 1 yr old, an abrupt decrease in mean arterial pressure (MAP) was induced nonpharmacologically by releasing a unilateral arterial thigh cuff (300 Torr) after 9 min of resting leg ischemia under two conditions: 1) ABR and CBR deactivation (control) and 2) ABR deactivation. Under control conditions, cuff release decreased MAP by 13 +/- 1 mmHg, whereas HR increased 11 +/- 2 beats/min. During ABR deactivation, neck suction was gradually applied to maintain carotid sinus transmural pressure during the initial 20 s after cuff release (suction). This attenuated the increase in HR (6 +/- 1 beats/min) and caused a greater decrease in MAP (18 +/- 2 mmHg, P < 0.05). Furthermore, estimated cardiac baroreflex responsiveness (DeltaHR/DeltaMAP) was significantly reduced during suction compared with control conditions. These findings suggest that the carotid baroreceptors contribute more importantly to the reflex control of HR than previously reported in healthy individuals.
Dysrhythmia of timed movements in Parkinson's disease and freezing of gait.
Tolleson, Christopher M; Dobolyi, David G; Roman, Olivia C; Kanoff, Kristen; Barton, Scott; Wylie, Scott A; Kubovy, Michael; Claassen, Daniel O
2015-10-22
A well-established motor timing paradigm, the Synchronization-Continuation Task (SCT), quantifies how accurately participants can time finger tapping to a rhythmic auditory beat (synchronization phase) then maintain this rhythm after the external auditory cue is extinguished, where performance depends on an internal representation of the beat (continuation phase). In this study, we investigated the hypothesis that Parkinson's disease (PD) patients with clinical symptoms of freezing of gait (FOG) exhibit exaggerated motor timing deficits. We predicted that dysrhythmia is exacerbated when finger tapping is stopped temporarily and then reinitiated under the guidance of an internal representation of the beat. Healthy controls and PD patients with and without FOG performed the SCT with and without the insertion of a 7-s cessation of motor tapping between synchronization and continuation phases. With no interruption between synchronization and continuation phases, PD patients, especially those with FOG, showed pronounced motor timing hastening at the slowest inter-stimulus intervals during the continuation phase. The introduction of a gap prior to the continuation phase had a beneficial effect for healthy controls and PD patients without FOG, although patients with FOG continued to show pronounced and persistent motor timing hastening. Ratings of freezing of gait severity across the entire sample of PD tracked closely with the magnitude of hastening during the continuation phase. These results suggest that PD is accompanied by a unique dysrhythmia of measured movements, with FOG reflecting a particularly pronounced disruption to internal rhythmic timing. Copyright © 2015 Elsevier B.V. All rights reserved.
Autonomic mechanisms of muscle metaboreflex control of heart rate.
O'Leary, D S
1993-04-01
Ischemia in active skeletal muscle induces reflex increases in systemic arterial pressure (SAP) and heart rate (HR), termed the muscle metaboreflex. When metaboreflex activation is maintained during postexercise muscle ischemia, SAP remains elevated; however, HR decreases. Why the HR responses differ with metaboreflex activation during exercise vs. during postexercise ischemia while the SAP responses are similar in each setting remains unclear. Two hypotheses were tested: 1) the increase in HR with muscle ischemia occurs predominantly via an increase in sympathetic activity, and 2) sympathetic activity to the heart remains elevated during post-exercise ischemia; however, HR decreases because of an increase in parasympathetic outflow. The muscle metaboreflex was activated in conscious dogs during treadmill exercise (3.2 kph, 0% grade) by progressively decreasing perfusion to the hindlimbs. Experiments were performed before and after muscarinic (atropine) or beta- (atenolol or propranolol) receptor blockade. In control experiments, once beyond the threshold for the reflex, the HR sensitivity of the muscle metaboreflex averaged -2.4 +/- 0.3 beats.min-1.mmHg-1 and the reflex open-loop gain averaged -3.2 +/- 0.3 (calculated as the ratio of the increase in HR or SAP to the decrease in hindlimb perfusion pressure beyond threshold). Atropine had no effect on either HR sensitivity (-2.7 +/- 0.4 beats.min-1.mmHg-1) or open-loop gain (-3.3 +/- 0.5, both P > 0.05 vs. control). However, pretreatment with beta-receptor antagonist significantly decreased both HR sensitivity (-0.7 +/- 0.1 beats.min-1.mmHg-1, P < 0.001) and open-loop gain (-1.9 +/- 0.3, P < 0.01). During postexercise ischemia, HR decreased while SAP remained elevated.(ABSTRACT TRUNCATED AT 250 WORDS)
Murphy, Barbara M; Worcester, Marian U C; Higgins, Rosemary O; Elliott, Peter C; Le Grande, Michael R; Mitchell, Fiona; Navaratnam, Hema; Turner, Alyna; Grigg, Leeanne; Tatoulis, James; Goble, Alan J
2013-01-01
While behavior change can improve risk factor profiles and prognosis after an acute cardiac event, patients need assistance to achieve sustained lifestyle changes. We developed the "Beating Heart Problems" cognitive-behavioral therapy and motivational interviewing program to support patients to develop behavioral and cognitive self-management skills. We report the results of a randomized controlled trial of the program. Patients (n = 275) consecutively admitted to 2 Melbourne hospitals after acute myocardial infarction (32%), coronary artery bypass graft surgery (40%), or percutaneous coronary intervention (28%) were randomized to treatment (T; n = 139) or control (C; n = 136). T group patients were invited to participate in the 8-week group-based program. Patients underwent risk factor screening 6 weeks after hospital discharge (before randomization) and again 4 and 12 months later. At both the followups, T and C groups were compared on 2-year risk of a recurrent cardiac event and key behavioral outcomes, using both intention-to-treat and "completers only" analyses. Patients ranged in age from 32 to 75 years (mean = 59.0 years; SD - 9.1 years). Most patients (86%) were men. Compared with the C group patients, T group patients tended toward greater reduction in 2-year risk, at both the 4- and 12-month followups. Significant benefits in dietary fat intake and functional capacity were also evident. The "Beating Heart Problems" program showed modest but important benefit over usual care at 4 and, to a lesser extent, 12 months. Modifications to the program such as the inclusion of booster sessions and translation to online delivery are likely to improve outcomes.
Heart rate at first postdischarge visit and outcomes in patients with heart failure.
Kim, Tae-Hun; Kim, Hyungseop; Kim, In-Cheol; Yoon, Hyuck-Jun; Park, Hyoung-Seob; Cho, Yun-Kyeong; Nam, Chang-Wook; Han, Seongwook; Hur, Seung-Ho; Kim, Yoon-Nyun
2018-07-01
Heart rate control is important to prevent adverse outcomes in patients with heart failure (HF). However, postdischarge activity may worsen heart rate control, resulting in readmission. This study aimed to explore the implications of the heart rate differences between discharge and the first outpatient visit (D-O diff). We retrospectively identified 458 patients (male: 46%; mean age: 72 years) discharged after HF. The heart rates at admission, discharge and first outpatient visit were analysed. The primary outcome was a composite of cardiovascular (CV) death and readmission of non-fatal myocardial infarction (MI), non-fatal stroke or non-fatal HF over a mean follow-up of 16 months. During follow-up, the clinical outcomes were noted in 223 patients (49%): HF, 199; stroke, 9; MI, 6; CV death, 9. The heart rate at the first outpatient visit (r=-0.311, P<0.001) and D-O diff (r=0.416, P<0.001) showed a better correlation with the time-to-clinical event than the heart rate at admission or discharge. The events group displayed a pronounced heart rate increase (13 beats/min) from discharge to the first outpatient visit compared with the event-free group (a decrease of 2 beats/min). A decrease less than -15 in the D-O diff showed a 4.5-fold risk of clinical outcomes during follow-up (P<0.001). A decreased D-O diff was related to the adverse outcomes of HF. The failure of heart rate control within more than 15 beats/min at the first outpatient visit was an independent factor for CV events. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
A dual mode breath sampler for the collection of the end-tidal and dead space fractions.
Salvo, P; Ferrari, C; Persia, R; Ghimenti, S; Lomonaco, T; Bellagambi, F; Di Francesco, F
2015-06-01
This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties. Copyright © 2015. Published by Elsevier Ltd.
The Simplest Demonstration on Acoustic Beats
ERIC Educational Resources Information Center
Ganci, Alessio; Ganci, Salvatore
2015-01-01
The classical demonstration experiment on acoustic beats using two signal generators and a dual trace oscilloscope is an important ingredient in teaching the subject. This short laboratory note aims to point out what may be the simplest demonstrative experiment on acoustic beats to carry out in a classroom without employing any lab apparatus.
Effects of intra-aortic counterpulsation on aortic wall energetics and damping: in vivo experiments.
Fischer, Edmundo I Cabrera; Bia, Daniel; Camus, Juan M; Zócalo, Yanina; de Forteza, Eduardo; Armentano, Ricardo L
2008-01-01
Intra-aortic balloon pumping (IABP) could modify the arterial biomechanics; however, its effects on arterial wall properties have not been fully explored. This dynamical study was designed to characterize the pressure-dependent and smooth muscle-dependent effects of IABP on aortic wall energetics in an in vivo animal model. Intra-aortic balloon pumping (1:2) was performed in six anesthetized sheep in which aortic pressure and diameter signals were measured in basal, augmented (during balloon inflation), and assisted (postaugmented) beats. Energy dissipation values in augmented and assisted beats were significantly higher than those observed in basal state (p < 0.05). Assisted beats showed a significant increase of wall damping with respect to basal and augmented beats (p < 0.05). Intra-aortic balloon pumping resulted in a significant increase of pulse wave velocity (p < 0.05) in augmented beats with respect to basal state (6.3 +/- 0.8 vs. 5.2 +/- 0.5 m x s(-1)); whereas values observed in assisted beats were significantly (p < 0.05) lower than those observed in augmented beats (4.9 +/- 0.5 vs. 6.3 +/- 0.8 m x s(-1)). Our findings show that IABP determined the pressure and smooth muscle-dependent changes in arterial wall energetics and damping properties in this animal model.
Wu, Guanhao; Yang, Yan; Zeng, Lijiang
2007-06-01
Koi carps frequently swim in burst-and-coast style, which consists of a burst phase and a coast phase. We quantify the swimming kinematics and the flow patterns generated by the carps in burst-and-coast swimming. In the burst phase, the carps burst in two modes: in the first, the tail beats for at least one cycle (multiple tail-beat mode); in the second, the tail beats for only a half-cycle (half tail-beat mode). The carp generates a vortex ring in each half-cycle beat. The vortex rings generated during bursting in multiple tail-beat mode form a linked chain, but only one vortex ring is generated in half tail-beat mode. The wake morphologies, such as momentum angle and jet angle, also show much difference between the two modes. In the burst phase, the kinematic data and the impulse obtained from the wake are linked to obtain the drag coefficient (C(d,burst) approximately 0.242). In the coast phase, drag coefficient (C(d,coast) approximately 0.060) is estimated from swimming speed deceleration. Our estimation suggests that nearly 45% of energy is saved when burst-and-coast swimming is used by the koi carps compared with steady swimming at the same mean speed.
Kiranyaz, Serkan; Ince, Turker; Pulkkinen, Jenni; Gabbouj, Moncef
2010-01-01
In this paper, we address dynamic clustering in high dimensional data or feature spaces as an optimization problem where multi-dimensional particle swarm optimization (MD PSO) is used to find out the true number of clusters, while fractional global best formation (FGBF) is applied to avoid local optima. Based on these techniques we then present a novel and personalized long-term ECG classification system, which addresses the problem of labeling the beats within a long-term ECG signal, known as Holter register, recorded from an individual patient. Due to the massive amount of ECG beats in a Holter register, visual inspection is quite difficult and cumbersome, if not impossible. Therefore the proposed system helps professionals to quickly and accurately diagnose any latent heart disease by examining only the representative beats (the so called master key-beats) each of which is representing a cluster of homogeneous (similar) beats. We tested the system on a benchmark database where the beats of each Holter register have been manually labeled by cardiologists. The selection of the right master key-beats is the key factor for achieving a highly accurate classification and the proposed systematic approach produced results that were consistent with the manual labels with 99.5% average accuracy, which basically shows the efficiency of the system.
Effect of alpha-tocopherol on bovine in vitro fertilization.
Marques, A; Santos, P; Antunes, G; Chaveiro, A; Moreira da Silva, F
2010-02-01
The objectives of this work are to determine if exogenous supplementation with alpha-tocopherol increases the in vitro fertilization (IVF) rate of bovine oocytes and improves viability of selected spermatozoa after 'swim-up'. The percentage of fertilized oocytes was significantly but negatively correlated (r = -0.941, p < 0.01) with the concentration of alpha-tocopherol. The control resulted in 95% of fertilized oocytes, which decreased as follows: 25 microM alpha-tocopherol (alpha25) 86%, 50 microM alpha-tocopherol (alpha50) 74%, 100 microM alpha-tocopherol (alpha100) 66% and 200 microM alpha-tocopherol (alpha200) 56%. Relatively to sperm viability after 'swim-up' with alpha-tocopherol supplementation, this antioxidant proved to have a beneficial effect as its concentration increased up to alpha50, decreasing for the concentrations of alpha100 and alpha200. Control resulted in 83% of live cells and 16% of dead cells; alpha25 resulted in 88% of live cells and 12% of dead cells; alpha50 resulted in 91% of live cells and 9% of dead cells; alpha100 resulted in 67% of live cells and 33% of dead cells; and finally alpha200 resulted in 57% of live cells and 42% of dead cells. In summary, the present study allows to conclude that, in our conditions, supplementation with the antioxidant alpha-tocopherol in IVF of bovine oocytes has a detrimental effect on fertilization rates. Nevertheless, exogenous supplementation with alpha-tocopherol at a concentration of 50 mM in the sperm-TALP media during the 'swim-up' technique has a significant beneficial effect on the selected spermatozoa viability.
Nonlinear amplitude dynamics in flagellar beating
NASA Astrophysics Data System (ADS)
Oriola, David; Gadêlha, Hermes; Casademunt, Jaume
2017-03-01
The physical basis of flagellar and ciliary beating is a major problem in biology which is still far from completely understood. The fundamental cytoskeleton structure of cilia and flagella is the axoneme, a cylindrical array of microtubule doublets connected by passive cross-linkers and dynein motor proteins. The complex interplay of these elements leads to the generation of self-organized bending waves. Although many mathematical models have been proposed to understand this process, few attempts have been made to assess the role of dyneins on the nonlinear nature of the axoneme. Here, we investigate the nonlinear dynamics of flagella by considering an axonemal sliding control mechanism for dynein activity. This approach unveils the nonlinear selection of the oscillation amplitudes, which are typically either missed or prescribed in mathematical models. The explicit set of nonlinear equations are derived and solved numerically. Our analysis reveals the spatio-temporal dynamics of dynein populations and flagellum shape for different regimes of motor activity, medium viscosity and flagellum elasticity. Unstable modes saturate via the coupling of dynein kinetics and flagellum shape without the need of invoking a nonlinear axonemal response. Hence, our work reveals a novel mechanism for the saturation of unstable modes in axonemal beating.
Nonlinear amplitude dynamics in flagellar beating.
Oriola, David; Gadêlha, Hermes; Casademunt, Jaume
2017-03-01
The physical basis of flagellar and ciliary beating is a major problem in biology which is still far from completely understood. The fundamental cytoskeleton structure of cilia and flagella is the axoneme, a cylindrical array of microtubule doublets connected by passive cross-linkers and dynein motor proteins. The complex interplay of these elements leads to the generation of self-organized bending waves. Although many mathematical models have been proposed to understand this process, few attempts have been made to assess the role of dyneins on the nonlinear nature of the axoneme. Here, we investigate the nonlinear dynamics of flagella by considering an axonemal sliding control mechanism for dynein activity. This approach unveils the nonlinear selection of the oscillation amplitudes, which are typically either missed or prescribed in mathematical models. The explicit set of nonlinear equations are derived and solved numerically. Our analysis reveals the spatio-temporal dynamics of dynein populations and flagellum shape for different regimes of motor activity, medium viscosity and flagellum elasticity. Unstable modes saturate via the coupling of dynein kinetics and flagellum shape without the need of invoking a nonlinear axonemal response. Hence, our work reveals a novel mechanism for the saturation of unstable modes in axonemal beating.
Nonlinear amplitude dynamics in flagellar beating
Casademunt, Jaume
2017-01-01
The physical basis of flagellar and ciliary beating is a major problem in biology which is still far from completely understood. The fundamental cytoskeleton structure of cilia and flagella is the axoneme, a cylindrical array of microtubule doublets connected by passive cross-linkers and dynein motor proteins. The complex interplay of these elements leads to the generation of self-organized bending waves. Although many mathematical models have been proposed to understand this process, few attempts have been made to assess the role of dyneins on the nonlinear nature of the axoneme. Here, we investigate the nonlinear dynamics of flagella by considering an axonemal sliding control mechanism for dynein activity. This approach unveils the nonlinear selection of the oscillation amplitudes, which are typically either missed or prescribed in mathematical models. The explicit set of nonlinear equations are derived and solved numerically. Our analysis reveals the spatio-temporal dynamics of dynein populations and flagellum shape for different regimes of motor activity, medium viscosity and flagellum elasticity. Unstable modes saturate via the coupling of dynein kinetics and flagellum shape without the need of invoking a nonlinear axonemal response. Hence, our work reveals a novel mechanism for the saturation of unstable modes in axonemal beating. PMID:28405357
Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon
2008-07-01
The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.
The Let's Beat the Bug! Campaign--A Statewide Active Public Education Against Bed Bugs in Minnesota.
Shindelar, Amelia K
2017-03-01
Bed bugs continue to affect society and place a burden on public health systems. Experiences of the Let’s Beat the Bug! campaign are presented to help information networks prepare personnel to effectively address questions about this pest. Following recommendations from the Minnesota state bed bug working group, an information line was established and the Web site (www.bedbugs.umn.edu) was revised. Data from both services were analyzed by geographic region and type of information requested. InformationLine primarily assisted people who had issues dealing with failed treatments and landlord reluctance to take effective measures against this pest. Web site visits indicated a preference for learning do-it-yourself control methods. There were commonalities in the information sought from both services. People were often looking for reassurance, in addition to information about basic prevention and control of bed bugs. We present here priority topics that public health personnel should be prepared to answer if they receive inquiries about bed bugs.
A sliding-control switch stabilizes synchronized states in a model of actuated cilia
NASA Astrophysics Data System (ADS)
Buchmann, Amy; Cortez, Ricardo; Fauci, Lisa
2017-11-01
A key function of cilia, flexible hairlike appendages located on the surface of a cell, is the transport of mucus in the lungs, where the cilia self-organize forming a metachronal wave that propels the surrounding fluid. Cilia also play an important role in the locomotion of ciliated microswimmers and other biological processes. To analyze the coordinated movement of cilia interacting through a fluid, we model each cilium as an elastic, actuated body whose beat pattern is driven by a geometric switch that drives the motion of the power and recovery strokes. The cilia are coupled to the viscous fluid using a numerical method based upon a centerline distribution of regularized Stokeslets. We first characterize the beat cycle and flow produced by a single cilium and then present results on the synchronization states between two cilia that show that the in-phase equilibrium is unstable while the anti-phase equilibrium is stable under the geometric switch model. Adding a sliding-control switching mechanism stabilizes the in-phase motion.
NASA Technical Reports Server (NTRS)
Aljuri, A. N.; Bursac, N.; Marini, R.; Cohen, R. J.
2001-01-01
Prolonged exposure to microgravity in space flight missions (days) impairs the mechanisms responsible for defense of arterial blood pressure (ABP) and cardiac output (CO) against orthostatic stress in the post-flight period. The mechanisms responsible for the observed orthostatic intolerance are not yet completely understood. Additionally, effective counter measures to attenuate this pathophysiological response are not available. The aim of this study was to investigate the ability of our proposed system identification method to predict closed-loop dynamic changes in TPR induced by changes in mean arterial pressure (MAP) and right atrial pressure (RAP). For this purpose we designed and employed a novel experimental animal model for the examination of arterial and cardiopulmonary baroreceptors in the dynamic closed-loop control of total peripheral resistance (TPR), and applied system identification to the analysis of beat-to-beat fluctuations in the measured signals. Grant numbers: NAG5-4989. c 2001. Elsevier Science Ltd. All rights reserved.
2013-12-10
Center Observer Controller/Trainer Mentors. Lieutenant Colonel Kevin Brown , Brigade Special Troop Battalion Lead Observer Controller/Trainer Mentor...December 2010): 13-19. Joint Readiness Training C-IED Lead Observer Controller/Trainer Mentors. Lieutenant Colonel Kevin S. Brown , Brigade Special... Gareth . “How the U.S. Quietly Lost the IED War in Afghanistan.” Inter Press Service News Agency (10 June 2013). Powledge, Timothy R. “Beating the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koven, C. D.; Chambers, J. Q.; Georgiou, K.
To better understand sources of uncertainty in projections of terrestrial carbon cycle feedbacks, we present an approach to separate the controls on modeled carbon changes. We separate carbon changes into four categories using a linearized, equilibrium approach: those arising from changed inputs (productivity-driven changes), and outputs (turnover-driven changes), of both the live and dead carbon pools. Using Coupled Model Intercomparison Project Phase 5 (CMIP5) simulations for five models, we find that changes to the live pools are primarily explained by productivity-driven changes, with only one model showing large compensating changes to live carbon turnover times. For dead carbon pools, themore » situation is more complex as all models predict a large reduction in turnover times in response to increases in productivity. This response arises from the common representation of a broad spectrum of decomposition turnover times via a multi-pool approach, in which flux-weighted turnover times are faster than mass-weighted turnover times. This leads to a shift in the distribution of carbon among dead pools in response to changes in inputs, and therefore a transient but long-lived reduction in turnover times. Since this behavior, a reduction in inferred turnover times resulting from an increase in inputs, is superficially similar to priming processes, but occurring without the mechanisms responsible for priming, we call the phenomenon "false priming", and show that it masks much of the intrinsic changes to dead carbon turnover times as a result of changing climate. These patterns hold across the fully coupled, biogeochemically coupled, and radiatively coupled 1 % yr −1 increasing CO 2 experiments. We disaggregate inter-model uncertainty in the globally integrated equilibrium carbon responses to initial turnover times, initial productivity, fractional changes in turnover, and fractional changes in productivity. For both the live and dead carbon pools, inter-model spread in carbon changes arising from initial conditions is dominated by model disagreement on turnover times, whereas inter-model spread in carbon changes from fractional changes to these terms is dominated by model disagreement on changes to productivity in response to both warming and CO 2 fertilization. However, the lack of changing turnover time control on carbon responses, for both live and dead carbon pools, in response to the imposed forcings may arise from a common lack of process representation behind changing turnover times (e.g., allocation and mortality for live carbon; permafrost, microbial dynamics, and mineral stabilization for dead carbon), rather than a true estimate of the importance of these processes.« less
Koven, C. D.; Chambers, J. Q.; Georgiou, K.; ...
2015-09-07
To better understand sources of uncertainty in projections of terrestrial carbon cycle feedbacks, we present an approach to separate the controls on modeled carbon changes. We separate carbon changes into four categories using a linearized, equilibrium approach: those arising from changed inputs (productivity-driven changes), and outputs (turnover-driven changes), of both the live and dead carbon pools. Using Coupled Model Intercomparison Project Phase 5 (CMIP5) simulations for five models, we find that changes to the live pools are primarily explained by productivity-driven changes, with only one model showing large compensating changes to live carbon turnover times. For dead carbon pools, themore » situation is more complex as all models predict a large reduction in turnover times in response to increases in productivity. This response arises from the common representation of a broad spectrum of decomposition turnover times via a multi-pool approach, in which flux-weighted turnover times are faster than mass-weighted turnover times. This leads to a shift in the distribution of carbon among dead pools in response to changes in inputs, and therefore a transient but long-lived reduction in turnover times. Since this behavior, a reduction in inferred turnover times resulting from an increase in inputs, is superficially similar to priming processes, but occurring without the mechanisms responsible for priming, we call the phenomenon "false priming", and show that it masks much of the intrinsic changes to dead carbon turnover times as a result of changing climate. These patterns hold across the fully coupled, biogeochemically coupled, and radiatively coupled 1 % yr −1 increasing CO 2 experiments. We disaggregate inter-model uncertainty in the globally integrated equilibrium carbon responses to initial turnover times, initial productivity, fractional changes in turnover, and fractional changes in productivity. For both the live and dead carbon pools, inter-model spread in carbon changes arising from initial conditions is dominated by model disagreement on turnover times, whereas inter-model spread in carbon changes from fractional changes to these terms is dominated by model disagreement on changes to productivity in response to both warming and CO 2 fertilization. However, the lack of changing turnover time control on carbon responses, for both live and dead carbon pools, in response to the imposed forcings may arise from a common lack of process representation behind changing turnover times (e.g., allocation and mortality for live carbon; permafrost, microbial dynamics, and mineral stabilization for dead carbon), rather than a true estimate of the importance of these processes.« less
Insecticide Transfer Efficiency and Lethal Load in Argentine Ants
Hooper-Bui, L. M.; Kwok, E S.C.; Buchholz, B. A.; ...
2015-07-03
Trophallaxis between individual worker ants and the toxicant load in dead and live Argentine ants (Linepithema humile) in colonies exposed to fipronil and hydramethylnon experimental baits were examined using accelerator mass spectrometry (AMS). About 50% of the content of the crop containing trace levels of 14C-sucrose, 14C-hydramethylnon, and 14C-fipronil was shared between single donor and recipient ants. Dead workers and queens contained significantly more hydramethylnon (122.7 and 22.4 amol/μg ant, respectively) than did live workers and queens (96.3 and 10.4 amol/μg ant, respectively). Dead workers had significantly more fipronil (420.3 amol/μg ant) than did live workers (208.5 amol/μg ant), butmore » dead and live queens had equal fipronil levels (59.5 and 54.3 amol/μg ant, respectively). Moreover, the distribution of fipronil differed within the bodies of dead and live queens; the highest amounts of fipronil were recovered in the thorax of dead queens whereas live queens had the highest levels in the head. Resurgence of polygynous ant colonies treated with hydramethylnon baits may be explained by queen survival resulting from sublethal doses due to a slowing of trophallaxis throughout the colony. The bait strategies and dose levels for controlling insect pests need to be based on the specific toxicant properties and trophic strategies for targeting the entire colony.« less
Insecticide Transfer Efficiency and Lethal Load in Argentine Ants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hooper-Bui, L. M.; Kwok, E S.C.; Buchholz, B. A.
Trophallaxis between individual worker ants and the toxicant load in dead and live Argentine ants (Linepithema humile) in colonies exposed to fipronil and hydramethylnon experimental baits were examined using accelerator mass spectrometry (AMS). About 50% of the content of the crop containing trace levels of 14C-sucrose, 14C-hydramethylnon, and 14C-fipronil was shared between single donor and recipient ants. Dead workers and queens contained significantly more hydramethylnon (122.7 and 22.4 amol/μg ant, respectively) than did live workers and queens (96.3 and 10.4 amol/μg ant, respectively). Dead workers had significantly more fipronil (420.3 amol/μg ant) than did live workers (208.5 amol/μg ant), butmore » dead and live queens had equal fipronil levels (59.5 and 54.3 amol/μg ant, respectively). Moreover, the distribution of fipronil differed within the bodies of dead and live queens; the highest amounts of fipronil were recovered in the thorax of dead queens whereas live queens had the highest levels in the head. Resurgence of polygynous ant colonies treated with hydramethylnon baits may be explained by queen survival resulting from sublethal doses due to a slowing of trophallaxis throughout the colony. The bait strategies and dose levels for controlling insect pests need to be based on the specific toxicant properties and trophic strategies for targeting the entire colony.« less
Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali
2015-01-01
We have designed and fabricated a miniature microscope from off-the-shelf components and webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters such as cell/tissue viability (e.g. Live/Dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60X, achieves a resolution as high as <2 μm, and possesses a long working distance of 4.5 mm (at a magnification of 8X). The mini-microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread applications in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required. PMID:26282117
A cost-effective fluorescence mini-microscope for biomedical applications.
Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali
2015-01-01
We have designed and fabricated a miniature microscope from off-the-shelf components and a webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters, such as cell/tissue viability (e.g. live/dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60×, achieves a resolution as high as <2 μm, and possesses a long working distance of 4.5 mm (at a magnification of 8×). The mini-microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including, but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread application in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required.
Liu, Shangdian; Liu, Zonghong; Li, Lulu; Liu, Pengfei; Liu, Hongyu
2015-05-13
To determine whether keeping the heart empty and beating is an effective technique to preserve hypertrophied pig hearts, and to investigate the underlying mechanism. Ten Bama Miniature pigs with hypertrophied hearts were divided into 2 groups (n = 5 in each group). One group underwent normothermic normokalemic simultaneous perfusion (NNSP). The other group was subjected to normothermic hypermokalemic simultaneous perfusion (NHSP) and used as controls. Cardiac contractive function, myocardial energy metabolism and myocardial perfusion were assessed using magnetic resonance imaging. Western blot analysis was carried out to determine the expression of Troponin I (cTnI), Troponin T (cTnT), SM-MHC, Casapase-3 and PARP4. TUNEL assay was used to detect apoptotic cardiomyocytes. Keeping the heart empty and beating with NNSP improved the preservation of contractile function in comparison with cardioplegic arrest using NHSP. No significant differences existed in the effects of NNSP and NHSP in maintaining myocardial energy metabolism. 13 % perfusion defects areas were found in one heart in the NHSP group, whereas none was found in all other hearts in both groups. The expressions of cTnI, cTnT, Casapase-3 and PARP4 in NHSP group were abundantly increased compared to NNSP group as measured by Western blotting. Conversely, the expression of SM-MHC in NHSP group was reduced compared with NNSP group. The number of TUNEL positive nuclei per mm(2) area was significantly increased in NHSP group compared with NNSP group. Keeping the heart beating with NNSP is an alternative technique to preserve hypertrophied hearts during valvular surgery.
Champeroux, P; Thireau, J; Judé, S; Laigot-Barbé, C; Maurin, A; Sola, M L; Fowler, J S L; Richard, S; Le Guennec, J Y
2015-01-01
Background and Purpose The present study was undertaken to investigate an effect of dofetilide, a potent arrhythmic blocker of the voltage-gated K+ channel, hERG, on cardiac autonomic control. Combined with effects on ardiomyocytes, these properties could influence its arrhythmic potency. Experimental Approach The short-term variability of beat-to-beat QT interval (STVQT), induced by dofetilide is a strong surrogate of Torsades de pointes liability. Involvement of autonomic modulation in STVQT was investigated in healthy cynomolgus monkeys and beagle dogs by power spectral analysis under conditions of autonomic blockade with hexamethonium. Key Results Increase in STVQT induced by dofetilide in monkeys and dogs was closely associated with an enhancement of endogenous heart rate and QT interval high-frequency (HF) oscillations. These effects were fully suppressed under conditions of autonomic blockade with hexamethonium. Ventricular arrhythmias, including Torsades de pointes in monkeys, were prevented in both species when HF oscillations were suppressed by autonomic blockade. Similar enhancements of heart rate HF oscillations were found in dogs with other hERG blockers described as causing Torsades de pointes in humans. Conclusions and Implications These results demonstrate for the first time that beat-to-beat ventricular repolarization variability and ventricular arrhythmias induced by dofetilide are dependent on endogenous HF autonomic oscillations in heart rate. When combined with evidence of hERG-blocking properties, enhancement of endogenous HF oscillations in heart rate could constitute an earlier and more sensitive biomarker than STVQT for Torsades de pointes liability, applicable to preclinical regulatory studies conducted in healthy animals. PMID:25625756
Porter, Julie A; Raebel, Marsha A; Conner, Douglas A; Lanty, Frances A; Vogel, Erin A; Gay, Elizabeth C; Merenich, John A
2004-06-01
To assess the benefit of sibutramine hydrochloride monohydrate within a weight management program. Prospective randomized controlled trial in a health maintenance organization. Obese patients (n = 588) starting a weight management program were enrolled. Patients were randomly assigned to participate in the program alone or to participate in the program and receive sibutramine for 12 months. Outcome measures were change in weight, body mass index (BMI), percentage body fat, serum lipids, serum glucose, and blood pressure. At baseline, there was a younger age and higher weight, BMI, and waist circumference in the drug group. There was more degenerative joint disease in the nondrug group. The mean weight loss at 6 months was 6.8 kg (95% confidence interval [CI], -7.4 to -6.1 kg) in the drug group vs 3.1 kg (95% CI, -3.8 to -2.4 kg) (P < .001) in the nondrug group. Weight loss was maintained at 12 months. Significant reductions in BMI, body fat, and waist circumference occurred in the drug group. There were no significant changes in laboratory values or blood pressure. Patients taking sibutramine experienced a significant increase in heart rate (1.7 beats/min [95% CI, 0.5-2.9 beats/min] vs -0.4 beats/min [95% CI, -1.5 to 0.8 beats/min]; P <.004). In this managed care setting, the effectiveness and safety of sibutramine were similar to those observed in randomized, double-blind clinical efficacy trials.
Navigating the auditory scene: an expert role for the hippocampus.
Teki, Sundeep; Kumar, Sukhbinder; von Kriegstein, Katharina; Stewart, Lauren; Lyness, C Rebecca; Moore, Brian C J; Capleton, Brian; Griffiths, Timothy D
2012-08-29
Over a typical career piano tuners spend tens of thousands of hours exploring a specialized acoustic environment. Tuning requires accurate perception and adjustment of beats in two-note chords that serve as a navigational device to move between points in previously learned acoustic scenes. It is a two-stage process that depends on the following: first, selective listening to beats within frequency windows, and, second, the subsequent use of those beats to navigate through a complex soundscape. The neuroanatomical substrates underlying brain specialization for such fundamental organization of sound scenes are unknown. Here, we demonstrate that professional piano tuners are significantly better than controls matched for age and musical ability on a psychophysical task simulating active listening to beats within frequency windows that is based on amplitude modulation rate discrimination. Tuners show a categorical increase in gray matter volume in the right frontal operculum and right superior temporal lobe. Tuners also show a striking enhancement of gray matter volume in the anterior hippocampus, parahippocampal gyrus, and superior temporal gyrus, and an increase in white matter volume in the posterior hippocampus as a function of years of tuning experience. The relationship with gray matter volume is sensitive to years of tuning experience and starting age but not actual age or level of musicality. Our findings support a role for a core set of regions in the hippocampus and superior temporal cortex in skilled exploration of complex sound scenes in which precise sound "templates" are encoded and consolidated into memory over time in an experience-dependent manner.
Champeroux, P; Thireau, J; Judé, S; Laigot-Barbé, C; Maurin, A; Sola, M L; Fowler, J S L; Richard, S; Le Guennec, J Y
2015-06-01
The present study was undertaken to investigate an effect of dofetilide, a potent arrhythmic blocker of the voltage-gated K(+) channel, hERG, on cardiac autonomic control. Combined with effects on ardiomyocytes, these properties could influence its arrhythmic potency. The short-term variability of beat-to-beat QT interval (STVQT ), induced by dofetilide is a strong surrogate of Torsades de pointes liability. Involvement of autonomic modulation in STVQT was investigated in healthy cynomolgus monkeys and beagle dogs by power spectral analysis under conditions of autonomic blockade with hexamethonium. Increase in STVQT induced by dofetilide in monkeys and dogs was closely associated with an enhancement of endogenous heart rate and QT interval high-frequency (HF) oscillations. These effects were fully suppressed under conditions of autonomic blockade with hexamethonium. Ventricular arrhythmias, including Torsades de pointes in monkeys, were prevented in both species when HF oscillations were suppressed by autonomic blockade. Similar enhancements of heart rate HF oscillations were found in dogs with other hERG blockers described as causing Torsades de pointes in humans. These results demonstrate for the first time that beat-to-beat ventricular repolarization variability and ventricular arrhythmias induced by dofetilide are dependent on endogenous HF autonomic oscillations in heart rate. When combined with evidence of hERG-blocking properties, enhancement of endogenous HF oscillations in heart rate could constitute an earlier and more sensitive biomarker than STVQT for Torsades de pointes liability, applicable to preclinical regulatory studies conducted in healthy animals. © 2015 The British Pharmacological Society.
Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin
2012-01-01
Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for treating ventricular arrhythmias arising from epicardial or endocardial sites and to noninvasively assess the mechanisms of these arrhythmias.
Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.
2012-01-01
Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for treating ventricular arrhythmias arising from epicardial or endocardial sites and to noninvasively assess the mechanisms of these arrhythmias. PMID:21984548
DEAD-box RNA helicase DDX3X inhibits DENV replication via regulating type one interferon pathway.
Li, Guanghao; Feng, Tingting; Pan, Wen; Shi, Xiaohong; Dai, Jianfeng
2015-01-02
Dengue virus (DENV) is a mosquito-borne virus that threatens approximately 2.5 billion people worldwide. Vaccines against DENV are currently unavailable. DEAD-box RNA helicases (DDXs) have been reported to participate in viral replication and host innate immune response. In the present study, we analyzed the role of 40 DDX proteins during DENV replication. Among these proteins, DDX3X showed antiviral effect against DENV infection. Viral replication significantly increased in DDX3X-silenced cells compared with the controls. The interferon (IFN)-β transcription level decreased during the early stage of DENV infection in DDX3X-silenced cells compared with that in the controls. DDX3X could stimulate IFN-β transcription through the IRF3 and the NFκB branches in DENV-infected cells. Our data imply that DDX3X, a member of DEAD-box RNA helicase, is necessary for IFN production and could inhibit DENV replication. Copyright © 2014 Elsevier Inc. All rights reserved.
Cartier, R; Brann, S; Dagenais, F; Martineau, R; Couturier, A
2000-02-01
We sought to report our recent experience with off-pump coronary artery revascularization in multivessel disease. Between October 1996 and December 1998, 300 off-pump beating heart operations were performed at the Montreal Heart Institute by a single surgeon, representing 94% of all procedures undertaken during this same time frame (97% for 1998). This cohort of patients was compared with 1870 patients operated on with cardiopulmonary bypass from 1995 to 1996. Mean age, sex distribution, and preoperative risk factors were comparable for the two groups. On average, 2.92 +/- 0.8 and 2.84 +/- 0.6 grafts per patient were completed in the beating heart and cardiopulmonary bypass groups, respectively. A majority of patients (70%) had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization." Ischemic time was shorter in the beating heart group (29.8 +/- 0.9 vs 45 +/- 0.4 minutes, P <.05). Similarly, the need for transfusion was significantly less in the beating heart group (beating heart operations, 34%; cardiopulmonary bypass, 66%; P <.005). Reduced use of postoperative intra-aortic counterpulsation, as well as a lower rise in creatine kinase MB isoenzyme, was observed in the beating heart group. Operative mortality rates (beating heart operations, 1. 3%; cardiopulmonary bypass, 2%) and perioperative myocardial infarction (beating heart operations, 3.6%; cardiopulmonary bypass, 4.2%) were comparable for the two groups. In a majority of patients, off-pump complete coronary artery revascularization is an acceptable alternative to conventional operations, yielding good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.
Coral reef fish predator maintains olfactory acuity in degraded coral habitats.
Natt, Michael; Lönnstedt, Oona M; McCormick, Mark I
2017-01-01
Coral reefs around the world are rapidly degrading due to a range of environmental stressors. Habitat degradation modifies the sensory landscape within which predator-prey interactions occur, with implications for olfactory-mediated behaviours. Predator naïve settlement-stage damselfish rely on conspecific damage-released odours (i.e., alarm odours) to inform risk assessments. Yet, species such as the Ambon damselfish, Pomacentrus amboinensis, become unable to respond appropriately to these cues when living in dead-degraded coral habitats, leading to increased mortality through loss of vigilance. Reef fish predators also rely on odours from damaged prey to locate, assess prey quality and engage in prey-stealing, but it is unknown whether their responses are also modified by the change to dead-degraded coral habitats. Implications for prey clearly depend on how their predatory counterparts are affected, therefore the present study tested whether olfactory-mediated foraging responses in the dusky dottyback, Pseudochromis fuscus, a common predator of P. amboinensis, were similarly affected by coral degradation. A y-maze was used to measure the ability of Ps. fuscus to detect and move towards odours, against different background water sources. Ps. fuscus were exposed to damage-released odours from juvenile P. amboinensis, or a control cue of seawater, against a background of seawater treated with either healthy or dead-degraded hard coral. Predators exhibited an increased time allocation to the chambers of y-mazes injected with damage-released odours, with comparable levels of response in both healthy and dead-degraded coral treated waters. In control treatments, where damage-released odours were replaced with a control seawater cue, fish showed no increased preference for either chamber of the y-maze. Our results suggest that olfactory-mediated foraging behaviours may persist in Ps. fuscus within dead-degraded coral habitats. Ps. fuscus may consequently gain a sensory advantage over P. amboinensis, potentially altering the outcome of predator-prey interactions.
Environmental Coupling Modulates the Attractors of Rhythmic Coordination
ERIC Educational Resources Information Center
Kudo, Kazutoshi; Park, Hyeonsaeng; Kay, Bruce A.; Turvey, M. T.
2006-01-01
A simple instance of coupling behavior to the environment is oscillating the hands in pace with metronome beats. This environmental coupling can be weaker (1 beat per cycle) or stronger (2 beats per cycle). The authors examined whether strength of environmental coupling enhanced the stability of in-phase bimanual coordination. Detuning by…
Training with Rhythmic Beat Gestures Benefits L2 Pronunciation in Discourse-Demanding Situations
ERIC Educational Resources Information Center
Gluhareva, Daria; Prieto, Pilar
2017-01-01
Recent research has shown that beat gestures (hand gestures that co-occur with speech in spontaneous discourse) are temporally integrated with prosodic prominence and that they help word memorization and discourse comprehension. However, little is known about the potential beneficial effects of beat gestures in second language (L2) pronunciation…
Exploring how musical rhythm entrains brain activity with electroencephalogram frequency-tagging
Nozaradan, Sylvie
2014-01-01
The ability to perceive a regular beat in music and synchronize to this beat is a widespread human skill. Fundamental to musical behaviour, beat and meter refer to the perception of periodicities while listening to musical rhythms and often involve spontaneous entrainment to move on these periodicities. Here, we present a novel experimental approach inspired by the frequency-tagging approach to understand the perception and production of rhythmic inputs. This approach is illustrated here by recording the human electroencephalogram responses at beat and meter frequencies elicited in various contexts: mental imagery of meter, spontaneous induction of a beat from rhythmic patterns, multisensory integration and sensorimotor synchronization. Collectively, our observations support the view that entrainment and resonance phenomena subtend the processing of musical rhythms in the human brain. More generally, they highlight the potential of this approach to help us understand the link between the phenomenology of musical beat and meter and the bias towards periodicities arising under certain circumstances in the nervous system. Entrainment to music provides a highly valuable framework to explore general entrainment mechanisms as embodied in the human brain. PMID:25385771
Musical rhythm and reading development: does beat processing matter?
Ozernov-Palchik, Ola; Patel, Aniruddh D
2018-05-20
There is mounting evidence for links between musical rhythm processing and reading-related cognitive skills, such as phonological awareness. This may be because music and speech are rhythmic: both involve processing complex sound sequences with systematic patterns of timing, accent, and grouping. Yet, there is a salient difference between musical and speech rhythm: musical rhythm is often beat-based (based on an underlying grid of equal time intervals), while speech rhythm is not. Thus, the role of beat-based processing in the reading-rhythm relationship is not clear. Is there is a distinct relation between beat-based processing mechanisms and reading-related language skills, or is the rhythm-reading link entirely due to shared mechanisms for processing nonbeat-based aspects of temporal structure? We discuss recent evidence for a distinct link between beat-based processing and early reading abilities in young children, and suggest experimental designs that would allow one to further methodically investigate this relationship. We propose that beat-based processing taps into a listener's ability to use rich contextual regularities to form predictions, a skill important for reading development. © 2018 New York Academy of Sciences.
NASA Astrophysics Data System (ADS)
Paik, Seoyoung; Lee, Sang-Yun; Boehme, Christoph
2011-03-01
Spin-dependent electronic transitions such as certain charge carrier recombination and transport processes in semiconductors are usually governed by the Pauli blockade within pairs of two paramagnetic centers. One implication of this is that the manipulation of spin states, e.g. by magnetic resonant excitation, can produce changes to electric currents of the given semiconductor material. If both spins are changed at the same time, quantum beat effects such as beat oscillation between resonantly induced spin Rabi nutation becomes detectable through current measurements. Here, we report on electrically detected spin Rabi beat oscillation caused by pairs of 31 P donor states and Pb interface defects at the phosphorous doped Si(111)/ Si O2 interface. Due to the g-factor anisotropy of the Pb center we can tune the intra pair Larmor frequency difference (so called Larmor separation) through orientation of the sample with regard to the external magnetic field. As the Larmor separation governs the spin Rabi beat oscillation, we show experimentally how the crystal orientation can influence the beat effect.
NASA Astrophysics Data System (ADS)
Shi, Zhi-Dong; Lin, Jian-Qiang; Bao, Huan-Huan; Liu, Shu; Xiang, Xue-Nong
2008-03-01
A photoelectric measurement system for measuring the beat length of birefringence fiber is set up including a set of rotating-wave-plate polarimeter using single photodiode. And two improved cutback methods suitable for measuring beat-length within millimeter range of high birefringence fiber are proposed through data processing technique. The cut length needs not to be restricted shorter than one centimeter so that the auto-cleaving machine is freely used, and no need to carefully operate the manually cleaving blade with low efficiency and poor success. The first method adopts the parameter-fitting to a saw-tooth function of tried beat length by the criterion of minimum square deviations, without special limitation on the cut length. The second method adopts linear-fitting in the divided length ranges, only restrict condition is the increment between different cut lengths less than one beat-length. For a section of holey high-birefringence fiber, we do experiments respectively by the two methods. The detecting error of beat-length is discussed and the advantage is compared.
Antonioletti, Mario; Biktashev, Vadim N; Jackson, Adrian; Kharche, Sanjay R; Stary, Tomas; Biktasheva, Irina V
2017-01-01
The BeatBox simulation environment combines flexible script language user interface with the robust computational tools, in order to setup cardiac electrophysiology in-silico experiments without re-coding at low-level, so that cell excitation, tissue/anatomy models, stimulation protocols may be included into a BeatBox script, and simulation run either sequentially or in parallel (MPI) without re-compilation. BeatBox is a free software written in C language to be run on a Unix-based platform. It provides the whole spectrum of multi scale tissue modelling from 0-dimensional individual cell simulation, 1-dimensional fibre, 2-dimensional sheet and 3-dimensional slab of tissue, up to anatomically realistic whole heart simulations, with run time measurements including cardiac re-entry tip/filament tracing, ECG, local/global samples of any variables, etc. BeatBox solvers, cell, and tissue/anatomy models repositories are extended via robust and flexible interfaces, thus providing an open framework for new developments in the field. In this paper we give an overview of the BeatBox current state, together with a description of the main computational methods and MPI parallelisation approaches.
NASA Astrophysics Data System (ADS)
Cui, Guozeng; Xu, Shengyuan; Ma, Qian; Li, Yongmin; Zhang, Zhengqiang
2018-05-01
In this paper, the problem of prescribed performance distributed output consensus for higher-order non-affine nonlinear multi-agent systems with unknown dead-zone input is investigated. Fuzzy logical systems are utilised to identify the unknown nonlinearities. By introducing prescribed performance, the transient and steady performance of synchronisation errors are guaranteed. Based on Lyapunov stability theory and the dynamic surface control technique, a new distributed consensus algorithm for non-affine nonlinear multi-agent systems is proposed, which ensures cooperatively uniformly ultimately boundedness of all signals in the closed-loop systems and enables the output of each follower to synchronise with the leader within predefined bounded error. Finally, simulation examples are provided to demonstrate the effectiveness of the proposed control scheme.
High Oxygen Partial Pressure Decreases Anemia-Induced Heart Rate Increase Equivalent to Transfusion
Feiner, John R.; Finlay-Morreale, Heather E.; Toy, Pearl; Lieberman, Jeremy A.; Viele, Maurene K.; Hopf, Harriet W.; Weiskopf, Richard B.
2011-01-01
Background Anemia is associated with morbidity and mortality and frequently leads to transfusion of erythrocytes. We sought to compare directly the effect of high inspired oxygen fraction vs. transfusion of erythrocytes on the anemia-induced increased heart rate (HR) in humans undergoing experimental acute isovolemic anemia. Methods We combined HR data from healthy subjects undergoing experimental isovolemic anemia in seven studies performed by our group. We examined HR changes associated with breathing 100% oxygen by non-rebreathing face mask vs. transfusion of erythrocytes at their nadir hemoglobin (Hb) concentration of 5 g/dL. Data were analyzed using a mixed-effects model. Results HR had an inverse linear relationship to hemoglobin concentration with a mean increase of 3.9 beats per minute per gram of Hb (beats/min/g Hb) decrease (95% confidence interval [CI], 3.7 – 4.1 beats/min/g Hb), P < 0.0001. Return of autologous erythrocytes significantly decreased HR by 5.3 beats/min/g Hb (95% CI, 3.8 – 6.8 beats/min/g Hb) increase, P < 0.0001. HR at nadir Hb of 5.6 g/dL (95% CI, 5.5 – 5.7 g/dL) when breathing air (91.4 beats/min; 95% CI, 87.6 – 95.2 beats/min) was reduced by breathing 100% oxygen (83.0 beats/min; 95% CI, 79.0 -87.0 beats/min), P < 0.0001. The HR at hemoglobin 5.6 g/dL when breathing oxygen was equivalent to the HR at Hb 8.9 g/dL when breathing air. Conclusions High arterial oxygen partial pressure reverses the heart rate response to anemia, probably owing to its usability, rather than its effect on total oxygen content. The benefit of high arterial oxygen partial pressure has significant potential clinical implications for the acute treatment of anemia and results of transfusion trials. PMID:21768873
Ivanov, Vadim A
2016-02-01
The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piece/ETT connector pairs with reduced instrumental dead space on CO2 elimination in a model of the premature neonate lung. The standard ETT connector was compared with a low-dead-space ETT connector and with a standard connector equipped with an insert. We compared the setups by measuring the CO2 elimination rate in an artificial lung ventilated via the connectors. The lung was connected to a ventilator via a standard circuit, a 2.5-mm ETT, and one of the connectors under investigation. The ventilator was run in volume-controlled continuous mandatory ventilation mode. The low-dead-space ETT connector/Y-piece and insert-equipped standard connector/Y-piece pairs had instrumental dead space reduced by 36 and 67%, respectively. With set tidal volumes (VT) of 2.5, 5, and 10 mL, in comparison with the standard ETT connector, the low-dead-space connector reduced CO2 elimination time by 4.5% (P < .05), 4.4% (P < .01), and 7.1% (not significant), respectively. The insert-equipped standard connector reduced CO2 elimination time by 13.5, 25.1, and 16.1% (all P < .01). The low-dead-space connector increased inspiratory resistance by 17.8% (P < .01), 9.6% (P < .05), and 5.0% (not significant); the insert-equipped standard connector increased inspiratory resistance by 9.1, 8.4, and 5.9% (all not significant). The low-dead-space connector decreased expiratory resistance by 6.8% (P < .01) and 1.8% (not significant) and increased it by 1.4% (not significant); the insert-equipped standard connector decreased expiratory resistance by 1.5 and 1% and increased it by 1% (all not significant). The low-dead-space connector increased work of breathing by 4.7% (P < .01), 3.8% (P < .01), and 2.5% (not significant); the insert-equipped standard connector increased it by 0.8% (not significant), 2.5% (P < .01), and 2.8% (P < .01). Both methods of instrumental dead-space reduction led to improvements in artificial lung ventilation. Negative effects on resistance and work of breathing appeared minimal. Further testing in vivo should be performed to confirm the lung model results and, if successful, translated into clinical practice. Copyright © 2016 by Daedalus Enterprises.
Beat-to-beat heart rate estimation fusing multimodal video and sensor data
Antink, Christoph Hoog; Gao, Hanno; Brüser, Christoph; Leonhardt, Steffen
2015-01-01
Coverage and accuracy of unobtrusively measured biosignals are generally relatively low compared to clinical modalities. This can be improved by exploiting redundancies in multiple channels with methods of sensor fusion. In this paper, we demonstrate that two modalities, skin color variation and head motion, can be extracted from the video stream recorded with a webcam. Using a Bayesian approach, these signals are fused with a ballistocardiographic signal obtained from the seat of a chair with a mean absolute beat-to-beat estimation error below 25 milliseconds and an average coverage above 90% compared to an ECG reference. PMID:26309754
Beat-to-beat heart rate estimation fusing multimodal video and sensor data.
Antink, Christoph Hoog; Gao, Hanno; Brüser, Christoph; Leonhardt, Steffen
2015-08-01
Coverage and accuracy of unobtrusively measured biosignals are generally relatively low compared to clinical modalities. This can be improved by exploiting redundancies in multiple channels with methods of sensor fusion. In this paper, we demonstrate that two modalities, skin color variation and head motion, can be extracted from the video stream recorded with a webcam. Using a Bayesian approach, these signals are fused with a ballistocardiographic signal obtained from the seat of a chair with a mean absolute beat-to-beat estimation error below 25 milliseconds and an average coverage above 90% compared to an ECG reference.
Ozdamar, Ozcan; Bohorquez, Jorge; Mihajloski, Todor; Yavuz, Erdem; Lachowska, Magdalena
2011-01-01
Electrophysiological indices of auditory binaural beats illusions are studied using late latency evoked responses. Binaural beats are generated by continuous monaural FM tones with slightly different ascending and descending frequencies lasting about 25 ms presented at 1 sec intervals. Frequency changes are carefully adjusted to avoid any creation of abrupt waveform changes. Binaural Interaction Component (BIC) analysis is used to separate the neural responses due to binaural involvement. The results show that the transient auditory evoked responses can be obtained from the auditory illusion of binaural beats.
Studies of ZVS soft switching of dual-active-bridge isolated bidirectional DC-DC converters
NASA Astrophysics Data System (ADS)
Xu, Fei; Zhao, Feng; Shi, Qibiao; Wen, Xuhui
2018-05-01
To operate dual-active-bridge isolated bidirectional dc- dc converter (DAB) at high efficiency, the two bridge switches must operate with Zero-Voltage-Switching (ZVS) over as wide an operating range as possible. This paper proposes a new perspective on realizing ZVS in dead-time. An exact theoretical analysis and mathematical mode is built to explain the process of ZVS switching in dead-time under Single Phase Shift (SPS) control strategy. In order to assure the two bridge switches operate on soft switching, every SPS switching point is analyzed. Generally, dead-time will be determined when the power electronic devices is selected. The key factor to realizing ZVS is the size of the end time of resonance comparing to dead-time. Through detailed analysis, it can obtain the conditions of all switches achieving ZVS turn-on and turn-off. Finally, simulation validates the theoretical analysis and some advice are given to realize the ZVS soft switching.
Explosive Model Tarantula V1/JWL++ Calibration of LX-17: #2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souers, P C; Vitello, P
2009-05-01
Tarantula V1 is a kinetic package for reactive flow codes that seeks to describe initiation, failure, dead zones and detonation simultaneously. The most important parameter is P1, the pressure between the initiation and failure regions. Both dead zone formation and failure can be largely controlled with this knob. However, V1 does failure with low settings and dead zones with higher settings, so that it cannot fulfill its purpose in the current format. To this end, V2 is under test. The derivation of the initiation threshold P0 is discussed. The derivation of the initiation pressure-tau curve as an output of Tarantulamore » shows that the initiation package is sound. A desensitization package is also considered.« less
Focusing on the Basics in Beat-the-Odds Schools. Policy Brief
ERIC Educational Resources Information Center
Lefkowits, Laura; Woempner, Carolyn
2006-01-01
Researchers at Mid-Continent Research for Education and Learning (McREL) recently completed a study of "beat-the-odds" schools--high-needs schools that demonstrated atypically high student achievement. This policy brief draws from the report of the study's findings, "High-Needs Schools--What Does It Take to Beat the Odds?"…
Sponsoring True Feeling: Literacy, "Parrhêsia," and Civic "Mythos" in the Writings of Detained Youth
ERIC Educational Resources Information Center
Catchings, Libby
2016-01-01
This qualitative study traces different articulations of the public, emotional honesty, and economic advantage in the literacy sponsorship of detained writer Lil' Purp by "The Beat Within," a publication for incarcerated youth and adults. Findings are compared to "The Beat"'s own account of Purp's progress, revealing a set of…
The Short Supply of Saints: Limits on Replication of Models that "Beat the Odds"
ERIC Educational Resources Information Center
Wilder, Tamara; Jacobsen, Rebecca
2010-01-01
Researchers have identified effective practices that allow schools to "beat the odds" and close the reading achievement gap. Although identifying these practices is important, researchers have paid little attention to the work it takes to implement them. Through interviews with teachers who work at schools identified as beating the odds, this…
Observation of ground-state quantum beats in atomic spontaneous emission.
Norris, D G; Orozco, L A; Barberis-Blostein, P; Carmichael, H J
2010-09-17
We report ground-state quantum beats in spontaneous emission from a continuously driven atomic ensemble. Beats are visible only in an intensity autocorrelation and evidence spontaneously generated coherence in radiative decay. Our measurement realizes a quantum eraser where a first photon detection prepares a superposition and a second erases the "which path" information in the intermediate state.
Dependency of Calcium Alternans on Ryanodine Receptor Refractoriness
Alvarez-Lacalle, Enric; Cantalapiedra, Inma R.; Peñaranda, Angelina; Cinca, Juan; Hove-Madsen, Leif; Echebarria, Blas
2013-01-01
Background Rapid pacing rates induce alternations in the cytosolic calcium concentration caused by fluctuations in calcium released from the sarcoplasmic reticulum (SR). However, the relationship between calcium alternans and refractoriness of the SR calcium release channel (RyR2) remains elusive. Methodology/Principal Findings To investigate how ryanodine receptor (RyR2) refractoriness modulates calcium handling on a beat-to-beat basis using a numerical rabbit cardiomyocyte model. We used a mathematical rabbit cardiomyocyte model to study the beat-to-beat calcium response as a function of RyR2 activation and inactivation. Bi-dimensional maps were constructed depicting the beat-to-beat response. When alternans was observed, a novel numerical clamping protocol was used to determine whether alternans was caused by oscillations in SR calcium loading or by RyR2 refractoriness. Using this protocol, we identified regions of RyR2 gating parameters where SR calcium loading or RyR2 refractoriness underlie the induction of calcium alternans, and we found that at the onset of alternans both mechanisms contribute. At low inactivation rates of the RyR2, calcium alternans was caused by alternation in SR calcium loading, while at low activation rates it was caused by alternation in the level of available RyR2s. Conclusions/Significance We have mapped cardiomyocyte beat-to-beat responses as a function of RyR2 activation and inactivation, identifying domains where SR calcium load or RyR2 refractoriness underlie the induction of calcium alternans. A corollary of this work is that RyR2 refractoriness due to slow recovery from inactivation can be the cause of calcium alternans even when alternation in SR calcium load is present. PMID:23390511
Cross-cultural influences on rhythm processing: reproduction, discrimination, and beat tapping
Cameron, Daniel J.; Bentley, Jocelyn; Grahn, Jessica A.
2015-01-01
The structures of musical rhythm differ between cultures, despite the fact that the ability to entrain movement to musical rhythm occurs in virtually all individuals across cultures. To measure the influence of culture on rhythm processing, we tested East African and North American adults on perception, production, and beat tapping for rhythms derived from East African and Western music. To assess rhythm perception, participants identified whether pairs of rhythms were the same or different. To assess rhythm production, participants reproduced rhythms after hearing them. To assess beat tapping, participants tapped the beat along with repeated rhythms. We expected that performance in all three tasks would be influenced by the culture of the participant and the culture of the rhythm. Specifically, we predicted that a participant’s ability to discriminate, reproduce, and accurately tap the beat would be better for rhythms from their own culture than for rhythms from another culture. In the rhythm discrimination task, there were no differences in discriminating culturally familiar and unfamiliar rhythms. In the rhythm reproduction task, both groups reproduced East African rhythms more accurately than Western rhythms, but East African participants also showed an effect of cultural familiarity, leading to a significant interaction. In the beat tapping task, participants in both groups tapped the beat more accurately for culturally familiar than for unfamiliar rhythms. Moreover, there were differences between the two participant groups, and between the two types of rhythms, in the metrical level selected for beat tapping. The results demonstrate that culture does influence the processing of musical rhythm. In terms of the function of musical rhythm, our results are consistent with theories that musical rhythm enables synchronization. Musical rhythm may foster musical cultural identity by enabling within-group synchronization to music, perhaps supporting social cohesion. PMID:26029122
Cross, Troy J.; Keller-Ross, Manda; Issa, Amine; Wentz, Robert; Taylor, Bryan; Johnson, Bruce
2015-01-01
Study Objectives: To determine the impact of averaging window-length on the “desaturation” indexes (DIs) obtained via overnight pulse oximetry (SpO2) at high altitude. Design: Overnight SpO2 data were collected during a 10-day sojourn at high altitude. SpO2 was obtained using a commercial wrist-worn finger oximeter whose firmware was modified to store unaveraged beat-to-beat data. Simple moving averages of window lengths spanning 2 to 20 cardiac beats were retrospectively applied to beat-to-beat SpO2 datasets. After SpO2 artifacts were removed, the following DIs were then calculated for each of the averaged datasets: oxygen desaturation index (ODI); total sleep time with SpO2 < 80% (TST < 80), and the lowest SpO2 observed during sleep (SpO2 low). Setting: South Base Camp, Mt. Everest (5,364 m elevation). Participants: Five healthy, adult males (35 ± 5 y; 180 ± 1 cm; 85 ± 4 kg). Interventions: N/A. Measurements and Results: 49 datasets were obtained from the 5 participants, totalling 239 hours of data. For all window lengths ≥ 2 beats, ODI and TST < 80 were lower, and SpO2 low was higher than those values obtained from the beat-to-beat SpO2 time series data (P < 0.05). Conclusions: Our findings indicate that increasing oximeter averaging window length progressively underestimates the frequency and magnitude of sleep disordered breathing events at high altitude, as indirectly assessed via the desaturation indexes. Citation: Cross TJ, Keller-Ross M, Issa A, Wentz R, Taylor B, Johnson B. The impact of averaging window length on the “desaturation” indexes obtained via overnight pulse oximetry at high altitude. SLEEP 2015;38(8):1331–1334. PMID:25581919
Grose, John H; Mamo, Sara K
2012-01-01
The purpose of this study was to determine the reliability of the electrophysiological binaural beat steady state response as a gauge of temporal fine structure coding, particularly as it relates to the aging auditory system. The hypothesis was that the response would be more robust in a lower, than in a higher, frequency region and in younger, than in older, adults. Two experiments were undertaken. The first measured the 40 Hz binaural beat steady state response elicited by tone pairs in two frequency regions: lower (390 and 430 Hz tone pair) and higher (810 and 850 Hz tone pair). Frequency following responses (FFRs) evoked by the tones were also recorded. Ten young adults with normal hearing participated. The second experiment measured the binaural beat and FFRs in older adults but only in the lower frequency region. Fourteen older adults with relatively normal hearing participated. Response metrics in both experiments included response component signal-to-noise ratio (F statistic) and magnitude-squared coherence. Experiment 1 showed that FFRs were elicited in both frequency regions but were more robust in the lower frequency region. Binaural beat responses elicited by the lower frequency pair of tones showed greater amplitude fluctuation within a participant than the respective FFRs. Experiment 2 showed that older adults exhibited similar FFRs to younger adults, but proportionally fewer older participants showed binaural beat responses. Age differences in onset responses were also observed. The lower prevalence of the binaural beat response in older adults, despite the presence of FFRs, provides tentative support for the sensitivity of this measure to age-related deficits in temporal processing. However, the lability of the binaural beat response advocates caution in its use as an objective measure of fine structure coding.
Nagel, Christina; Trenk, Lisa; Aurich, Christine; Ille, Natascha; Pichler, Martina; Drillich, Marc; Pohl, Werner; Aurich, Jörg
2016-03-15
Increased cortisol release in parturient cows may either represent a stress response or is part of the endocrine changes that initiate calving. Acute stress elicits an increase in heart rate and decrease in heart rate variability (HRV). Therefore, we analyzed cortisol concentration, heart rate and HRV variables standard deviation of beat-to-beat interval (SDRR) and root mean square of successive beat-to-beat intervals (RMSSD) in dairy cows allowed to calve spontaneously (SPON, n = 6) or with PGF2α-induced preterm parturition (PG, n = 6). We hypothesized that calving is a stressor, but induced parturition is less stressful than term calving. Saliva collection for cortisol analysis and electrocardiogram recordings for heart rate and HRV analysis were performed from 32 hours before to 18.3 ± 0.7 hours after delivery. Cortisol concentration increased in SPON and PG cows, peaked 15 minutes after delivery (P < 0.001) but was higher in SPON versus PG cows (P < 0.001) during and within 2 hours after calving. Heart rate peaked during the expulsive phase of labor and was higher in SPON than in PG cows (time × group P < 0.01). The standard deviation of beat-to-beat interval and RMSSD peaked at the end of the expulsive phase of labor (P < 0.001), indicating high vagal activity. Standard deviation of beat-to-beat interval (P < 0.01) and RMSSD (P < 0.05) were higher in SPON versus PG cows. Based on physiological stress parameters, calving is perceived as stressful but expulsion of the calf is associated with a transiently increased vagal tone which may enhance uterine contractility. Copyright © 2016 Elsevier Inc. All rights reserved.
Cross-cultural influences on rhythm processing: reproduction, discrimination, and beat tapping.
Cameron, Daniel J; Bentley, Jocelyn; Grahn, Jessica A
2015-01-01
The structures of musical rhythm differ between cultures, despite the fact that the ability to entrain movement to musical rhythm occurs in virtually all individuals across cultures. To measure the influence of culture on rhythm processing, we tested East African and North American adults on perception, production, and beat tapping for rhythms derived from East African and Western music. To assess rhythm perception, participants identified whether pairs of rhythms were the same or different. To assess rhythm production, participants reproduced rhythms after hearing them. To assess beat tapping, participants tapped the beat along with repeated rhythms. We expected that performance in all three tasks would be influenced by the culture of the participant and the culture of the rhythm. Specifically, we predicted that a participant's ability to discriminate, reproduce, and accurately tap the beat would be better for rhythms from their own culture than for rhythms from another culture. In the rhythm discrimination task, there were no differences in discriminating culturally familiar and unfamiliar rhythms. In the rhythm reproduction task, both groups reproduced East African rhythms more accurately than Western rhythms, but East African participants also showed an effect of cultural familiarity, leading to a significant interaction. In the beat tapping task, participants in both groups tapped the beat more accurately for culturally familiar than for unfamiliar rhythms. Moreover, there were differences between the two participant groups, and between the two types of rhythms, in the metrical level selected for beat tapping. The results demonstrate that culture does influence the processing of musical rhythm. In terms of the function of musical rhythm, our results are consistent with theories that musical rhythm enables synchronization. Musical rhythm may foster musical cultural identity by enabling within-group synchronization to music, perhaps supporting social cohesion.
Goswami, Usha; Huss, Martina; Mead, Natasha; Fosker, Tim; Verney, John P
2013-05-01
In a recent study, we reported that the accurate perception of beat structure in music ('perception of musical meter') accounted for over 40% of the variance in single word reading in children with and without dyslexia (Huss et al., 2011). Performance in the musical task was most strongly associated with the auditory processing of rise time, even though beat structure was varied by manipulating the duration of the musical notes. Here we administered the same musical task a year later to 88 children with and without dyslexia, and used new auditory processing measures to provide a more comprehensive picture of the auditory correlates of the beat structure task. We also measured reading comprehension and nonword reading in addition to single word reading. One year later, the children with dyslexia performed more poorly in the musical task than younger children reading at the same level, indicating a severe perceptual deficit for musical beat patterns. They now also had significantly poorer perception of sound rise time than younger children. Longitudinal analyses showed that the musical beat structure task was a significant longitudinal predictor of development in reading, accounting for over half of the variance in reading comprehension along with a linguistic measure of phonological awareness. The non-linguistic musical beat structure task is an important independent longitudinal and concurrent predictor of variance in reading attainment by children. The different longitudinal versus concurrent associations between musical beat perception and auditory processing suggest that individual differences in the perception of rhythmic timing are an important shared neural basis for individual differences in children in linguistic and musical processing. Copyright © 2012 Elsevier Ltd. All rights reserved.
[Regeneration of the ciliary beat of human ciliated cells].
Wolf, G; Koidl, B; Pelzmann, B
1991-10-01
The influence of an isotonic, alkaline saline solution (diluted "Emser Sole" or brine from the spa of Bad Ems) on the ciliary beat of isolated cultured human ciliated cells of the upper respiratory tract was investigated. The ciliary beat was observed via an inverted phase contrast microscope (Zeiss Axiomat IDPC) and measured microphotometrically under physiological conditions and after the damaging influence of 1% propanal solution. Under physiological conditions the saline solution had a positive, although statistically not significant influence on the frequency of the ciliary beat. After damage of the cultivated cells by 1% propanal solution, the saline solution had a significant better influence on the regeneration of the cultured cells than a physiological sodium chloride solution. It is concluded that diluted brine from Bad Ems has a positive effect on the ciliary beat of the respiratory epithelium and accelerates its regeneration after damage by viral and bacterial infections, surgery or inhaled noxae.
Metronome rate and walking foot contact time in young adults.
Dickstein, Ruth; Plax, Michael
2012-02-01
It is assumed that when people walk guided by an audible constant rate, they match foot contact to the external pace. The purpose of this preliminary study was to test that assumption by examining the temporal relationship between audible signals generated by a metronome and foot contact time during gait. Ten healthy young women were tested in walking repetitions guided by metronome rates of 60, 110, and 150 beats/min. Metronome beats and foot contact times were collected in real time. The findings indicated that foot contact was not fully synchronized with the auditory signals; the shortest time interval between the metronome beat and foot contact time was at the prescribed rate of 60 beats/min., while the longest interval was at the rate of 150 beats/min. The correlation between left and right foot contact times was highest with the slowest rate and lowest with the fastest rate.
Free-electron laser from wave-mechanical beats of 2 electron beams
NASA Technical Reports Server (NTRS)
Lichtenstein, R. M.
1982-01-01
It is possible, though technically difficult, to produce beams of free electrons that exhibit beats of a quantum mechanical nature. (1) the generation of electromagnetic radiation, e.g., light, based on the fact that the beats give rise to alternating charge and current densities; and a frequency shifter, based on the fact that a beam with beats constitutes a moving grating. When such a grating is exposed to external radiation of suitable frequency and direction, the reflected rediation will be shifted in frequency, since the grating is moving. A twofold increase of the frequency is readily attainable. It is shown that it is impossible to generate radiation, because the alternating electromagnetic fields that accompany the beats cannot reform themselves into freely propagating waves. The frequency shifter is useless as a practical device, because its reflectance is extremely low for realizable beams.
Kang, Zhuang-Li; Li, Xiang; He, Hong-Ju; Ma, Han-Jun; Song, Zhao-Jun
2017-08-01
A comprehensive study was conducted to evaluate the structural changes of meat and protein of pork batters produced by chopping or beating process through the phase-contrast micrograph, laser light scattering analyzer, scanning electronic microscopy and Raman spectrometer. The results showed that the shattered myofibrilla fragments were shorter and particle-sizes were smaller in the raw batter produced by beating process than those in the chopping process. Compared with the raw and cooked batters produced by chopping process, modifications in amide I and amide III bands revealed a significant decrease of α -helix content and an increase of β -sheet, β -turn and random coils content in the beating process. The changes in secondary structure of protein in the batter produced by beating process was thermally stable. Moreover, more tyrosine residues were buried, and more gauche-gauche-trans disulfide bonds conformations and hydrophobic interactions were formed in the batter produced by beating process.
NASA Astrophysics Data System (ADS)
Liu, Lisheng; Zhang, Heyong; Guo, Jin; Zhao, Shuai; Wang, Tingfeng
2012-08-01
In this paper, we report a mathematical derivation of probability density function (PDF) of time-interval between two successive photoelectrons of the laser heterodyne signal, and give a confirmation of the theoretical result by both numerical simulation and an experiment. The PDF curve of the beat signal displays a series of fluctuations, the period and amplitude of which are respectively determined by the beat frequency and the mixing efficiency. The beat frequency is derived from the frequency of fluctuations accordingly when the PDF curve is measured. This frequency measurement method still works while the traditional Fast Fourier Transform (FFT) algorithm hardly derives the correct peak value of the beat frequency in the condition that we detect 80 MHz beat signal with 8 Mcps (counts per-second) photons count rate, and this indicates an advantage of the PDF method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Lei; Department of Medical Physics, Basic Medical College, Hebei Medical University, Shijiazhuang, Hebei 050017; Li, Yu-Xian
2014-01-14
The transport properties in graphene-based asymmetric double velocity well (Fermi velocity inside the well less than that outside the well) and electrostatic well structures are investigated using the transfer matrix method. The results show that quantum beats occur in the oscillations of the conductance for asymmetric double velocity wells. The beating effect can also be found in asymmetric double electrostatic wells, but only if the widths of the two wells are different. The beat frequency for the asymmetric double well is exactly equal to the frequency difference between the oscillation rates in two isolated single wells with the same structuresmore » as the individual wells in the double well structure. A qualitative interpretation is proposed based on the fact that the resonant levels depend upon the sizes of the quantum wells. The beating behavior can provide a new way to identify the symmetry of double well structures.« less
Garske, Luke A; Lal, Ravin; Stewart, Ian B; Morris, Norman R; Cross, Troy J; Adams, Lewis
2017-05-01
Chest wall strapping has been used to assess mechanisms of dyspnea with restrictive lung disease. This study examined the hypothesis that dyspnea with restriction depends principally on the degree of reflex ventilatory stimulation. We compared dyspnea at the same (iso)ventilation when added dead space provided a component of the ventilatory stimulus during exercise. Eleven healthy men undertook a randomized controlled crossover trial that compared four constant work exercise conditions: 1 ) control (CTRL): unrestricted breathing at 90% gas exchange threshold (GET); 2 ) CTRL+dead space (DS): unrestricted breathing with 0.6-l dead space, at isoventilation to CTRL due to reduced exercise intensity; 3 ) CWS: chest wall strapping at 90% GET; and 4 ) CWS+DS: chest strapping with 0.6-l dead space, at isoventilation to CWS with reduced exercise intensity. Chest strapping reduced forced vital capacity by 30.4 ± 2.2% (mean ± SE). Dyspnea at isoventilation was unchanged with CTRL+DS compared with CTRL (1.93 ± 0.49 and 2.17 ± 0.43, 0-10 numeric rating scale, respectively; P = 0.244). Dyspnea was lower with CWS+DS compared with CWS (3.40 ± 0.52 and 4.51 ± 0.53, respectively; P = 0.003). Perceived leg fatigue was reduced with CTRL+DS compared with CTRL (2.36 ± 0.48 and 2.86 ± 0.59, respectively; P = 0.049) and lower with CWS+DS compared with CWS (1.86 ± 0.30 and 4.00 ± 0.79, respectively; P = 0.006). With unrestricted breathing, dead space did not change dyspnea at isoventilation, suggesting that dyspnea does not depend on the mode of reflex ventilatory stimulation in healthy individuals. With chest strapping, dead space presented a less potent stimulus to dyspnea, raising the possibility that leg muscle work contributes to dyspnea perception independent of the ventilatory stimulus. NEW & NOTEWORTHY Chest wall strapping was applied to healthy humans to simulate restrictive lung disease. With chest wall strapping, dyspnea was reduced when dead space substituted for part of a constant exercise stimulus to ventilation. Dyspnea associated with chest wall strapping depended on the contribution of leg muscle work to ventilatory stimulation. Chest wall strapping might not be a clinically relevant model to determine whether an alternative reflex ventilatory stimulus mimics the intensity of exertional dyspnea. Copyright © 2017 the American Physiological Society.
Revolutionizing Environmental Education through Indigenous Hip Hop Culture
ERIC Educational Resources Information Center
Gorlewski, Julie; Porfilio, Brad J.
2012-01-01
Based upon the life histories of six Indigenous hip hop artists of the Beat Nation artist collective, this essay captures how Indigenous hip hop has the potential to revolutionize environmental education. Hip hop provides Indigenous youth an emancipatory space to raise their opposition to neocolonial controls of Indigenous territories that…
Moving to the Beat: From Zumba to Hip-Hop Hoedown
ERIC Educational Resources Information Center
Toscano, Lisa; Ladda, Shawn; Bednarz, Lauren
2014-01-01
The importance of regular moderately intense exercise for overall wellness has been well documented by the Centers for Disease Control and Prevention and the American Academy of Pediatrics. Reductions in obesity, diabetes, heart disease, and osteoporosis, and increased brain function can be achieved by being active throughout life. Quality…
Klöcker, N; Verse, T; Rudolph, P
2003-03-01
In Germany more than 60 million units of nasal decongestants are prescribed or sold over the counter. The cytotoxic and ciliary-toxic potential of alpha-sympathomimetic decongestants is well established. Furthermore, in many of the marketed products preservatives are added, predominantly benzalchonium-chloride, which can lead to a further alteration of cell- and ciliary function. Recently a protective effect of dexpanthenol was found for the human nasal mucosa. The objective of the present studies was to prove the hypothesis that dexpanthenol is able to neutralise the toxic effects of both alpha-sympathomimetic decongestants, in particular those of xylometazoline, and those of benzalconium-chloride. Therefore, systematic cytotoxic and ex vivo in vitro ciliary-toxic studies were performed. After exposition to xylometazoline in concentrations of 0.1 % and 0.05 %, the influence of dexpanthenol (5 %) and benzalconium-chloride (0,01 %) was assessed by determination of a) cell growth of FL-cells of human amnion origin, and b) ciliary beat frequency of human nasal mucosa. All tests were performed placebo-controlled. Both hypotheses were confirmed. Dexpanthenol (5 %) reduces statistically significantly the concentration-dependent toxic effects of xylometazoline, and benzalchonium-cloride regarding cell growth and ciliary beat frequency (p < 0.001). The combination of xylometazoline with dexpanthenol, while benzalconium-chloride is eliminated, resulted in a further significant increase of cell growth and ciliary beat frequency (p < 0.001), similar to control. The additive application of dexpanthenol (5 %) with nasal decongestants and/or with preserved nasal sprays seems to be able to reduce the cell- and ciliary-toxic effects of these substances.
Rhythm perturbations in acoustically paced treadmill walking after stroke.
Roerdink, Melvyn; Lamoth, Claudine J C; van Kordelaar, Joost; Elich, Peter; Konijnenbelt, Manin; Kwakkel, Gert; Beek, Peter J
2009-09-01
In rehabilitation, acoustic rhythms are often used to improve gait after stroke. Acoustic cueing may enhance gait coordination by creating a stable coupling between heel strikes and metronome beats and provide a means to train the adaptability of gait coordination to environmental changes, as required in everyday life ambulation. To examine the stability and adaptability of auditory-motor synchronization in acoustically paced treadmill walking in stroke patients. Eleven stroke patients and 10 healthy controls walked on a treadmill at preferred speed and cadence under no metronome, single-metronome (pacing only paretic or nonparetic steps), and double-metronome (pacing both footfalls) conditions. The stability of auditory-motor synchronization was quantified by the variability of the phase relation between footfalls and beats. In a separate session, the acoustic rhythms were perturbed and adaptations to restore auditory-motor synchronization were quantified. For both groups, auditory-motor synchronization was more stable for double-metronome than single-metronome conditions, with stroke patients exhibiting an overall weaker coupling of footfalls to metronome beats than controls. The recovery characteristics following rhythm perturbations corroborated the stability findings and further revealed that stroke patients had difficulty in accelerating their steps and instead preferred a slower-step response to restore synchronization. In gait rehabilitation practice, the use of acoustic rhythms may be more effective when both footfalls are paced. In addition, rhythm perturbations during acoustically paced treadmill walking may not only be employed to evaluate the stability of auditory-motor synchronization but also have promising implications for evaluation and training of gait adaptations in neurorehabilitation practice.
Cui, Zhi; Ni, Nathan C; Wu, Jun; Du, Guo-Qing; He, Sheng; Yau, Terrence M; Weisel, Richard D; Sung, Hsing-Wen; Li, Ren-Ke
2018-01-01
Background: The post-myocardial infarction (MI) scar interrupts electrical impulse propagation and delays regional contraction, which contributes to ventricular dysfunction. We investigated the potential of an injectable conductive biomaterial to restore scar tissue conductivity and re-establish synchronous ventricular contraction. Methods: A conductive biomaterial was generated by conjugating conductive polypyrrole (PPY) onto chitosan (CHI) backbones. Trypan blue staining of neonatal rat cardiomyocytes (CMs) cultured on biomaterials was used to evaluate the biocompatibility of the conductive biomaterials. Ca 2+ imaging was used to visualize beating CMs. A cryoablation injury rat model was used to investigate the ability of PPY:CHI to improve cardiac electrical propagation in the injured heart in vivo . Electromyography was used to evaluate conductivity of scar tissue ex vivo . Results: Cell survival and morphology were similar between cells cultured on biomaterials-coated and uncoated-control dishes. PPY:CHI established synchronous contraction of two distinct clusters of spontaneously-beating CMs. Intramyocardial PPY:CHI injection into the cryoablation-induced injured region improved electrical impulse propagation across the scarred tissue and decreased the QRS interval, whereas saline- or CHI-injected hearts continued to have delayed propagation patterns and significantly reduced conduction velocity compared to healthy controls. Ex vivo evaluation found that scar tissue from PPY:CHI-treated rat hearts had higher signal amplitude compared to those from saline- or CHI-treated rat heart tissue. Conclusions: The PPY:CHI biomaterial is electrically conductive, biocompatible and injectable. It improved synchronous contraction between physically separated beating CM clusters in vitro . Intra-myocardial injection of PPY:CHI following cardiac injury improved electrical impulse propagation of scar tissue in vivo .
Glasson, Colleen; Chapman, Kathy; Wilson, Tamara; Gander, Kristi; Hughes, Clare; Hudson, Nayerra; James, Erica
2013-11-01
To determine if localised programmes that are successful in engaging the community can add value to larger fruit and vegetable mass-media campaigns by evaluating the results of the Eat It To Beat It programme. The Eat It To Beat It programme is a multi-strategy intervention that uses community-based education and ‘below the line’ social marketing to increase fruit and vegetable consumption in parents. This programme was evaluated by a controlled before-and-after study with repeat cross-sectional data collected via computer-assisted telephone interviews with 1403 parents before the intervention (2008) and 1401 following intervention delivery (2011). The intervention area was the Hunter region and the control area was the New England region of New South Wales, Australia. Parents of primary school-aged children (Kindergarten to Year 6). The programme achieved improvements in knowledge of recommended intakes for fruit and vegetables and some positive changes in knowledge of serving size for vegetables. Exposure to the programme resulted in a net increase of 0.5 servings of fruit and vegetables daily for those who recalled the programme compared with those who did not (P = 0.004). Increased intake of fruit and vegetables was significantly associated with increasing exposure to programme strategies. The Eat It To Beat It programme demonstrates that an increase in consumption of fruit and vegetables can be achieved by programmes that build on the successes of larger mass-media and social-marketing campaigns.This suggests that funding for localised, community-based programmes should be increased.
Heart Rate Recovery in the First Minute at the Six-Minute Walk Test in Patients with Heart Failure
Lindemberg, Sabrina; Chermont, Sergio; Quintão, Mônica; Derossi, Milena; Guilhon, Sergio; Bernardez, Sabrina; Marchese, Luana; Martins, Wolney; Nóbrega, Antônio Claudio L.; Mesquita, Evandro Tinoco
2014-01-01
Background Heart rate recovery at one minute of rest (HRR1) is a predictor of mortality in heart failure (HF), but its prognosis has not been assessed at six-minute walk test (6MWT) in these patients. Objective This study aimed to determine the HRR1 at 6MWT in patients with HF and its correlation with six-minute walk distance (6MWD). Methods Cross-sectional, controlled protocol with 161 individuals, 126 patients with stable systolic HF, allocated into 2 groups (G1 and G2) receiving or not β-blocker and 35 volunteers in control group (G3) had HRR1 recorded at the 6MWT. Results HRR1 and 6MWD were significantly different in the 3 groups. Mean values of HRR1 and 6MWD were: HRR1 = 12 ± 14 beat/min G1; 18 ± 16 beat/min G2 and 21 ± 13 beat/min G3; 6MWD = 423 ± 102 m G1; 396 ± 101m G2 and 484 ± 96 m G3 (p < 0.05). Results showed a correlation between HRR1 and 6MWD in G1(r = 0.3; p = 0.04) and in G3(r = 0.4; p= 0.03), but not in G2 (r= 0.12; p= 0.48). Conclusion HRR1 response was attenuated in patients using βB and showed correlation with 6MWD, reflecting better exercise tolerance. HRR1 after 6MWT seems to represent an alternative when treadmill tests could not be tolerated. PMID:24714794
Flower-visiting behavior of male bees is triggered by nectar-feeding insects.
Sugiura, Shinji; Abe, Tetsuto; Yamaura, Yuichi; Makino, Shun'ichi
2007-08-01
Bees are important pollinators for many flowering plants. Female bees are thought to be more effective pollinators than male bees because they carry much more pollen than males. Males of some solitary bee species are known to patrol near flowers that females visit. Because patrolling males visit flowers to mate or defend their territories, they may function as pollinators. However, the significance of patrolling males to pollination has not been studied. We studied males of a solitary bee, Heriades fulvohispidus (Megachilidae), patrolling near flowers and visiting flowers that attracted nectar-feeding insects, including conspecifics, on the Ogasawara (Bonin) Islands. To test the hypothesis that patrolling male bees may function as pollen vectors, we compared the frequency of visits by H. fulvohispidus to flowers of an endemic plant, Schima mertensiana (Theaceae); comparisons were made among flowers with a dead H. fulvohispidus, a dead beetle, a piece of plastic, and nothing (control flowers). Patrolling H. fulvohispidus more frequently visited flowers with a dead conspecific, a dead beetle, or a piece of plastic than the control flowers. Our experiment demonstrates that nectar-feeding insects (including conspecifics and other insects) enhance the flower-visiting frequency of patrolling H. fulvohispidus males on S. mertensiana flowers. Furthermore, we observed S. mertensiana pollen on patrolling males as well as females, suggesting that male bees may also function as pollen vectors.
Flower-visiting behavior of male bees is triggered by nectar-feeding insects
NASA Astrophysics Data System (ADS)
Sugiura, Shinji; Abe, Tetsuto; Yamaura, Yuichi; Makino, Shun'ichi
2007-08-01
Bees are important pollinators for many flowering plants. Female bees are thought to be more effective pollinators than male bees because they carry much more pollen than males. Males of some solitary bee species are known to patrol near flowers that females visit. Because patrolling males visit flowers to mate or defend their territories, they may function as pollinators. However, the significance of patrolling males to pollination has not been studied. We studied males of a solitary bee, Heriades fulvohispidus (Megachilidae), patrolling near flowers and visiting flowers that attracted nectar-feeding insects, including conspecifics, on the Ogasawara (Bonin) Islands. To test the hypothesis that patrolling male bees may function as pollen vectors, we compared the frequency of visits by H. fulvohispidus to flowers of an endemic plant, Schima mertensiana (Theaceae); comparisons were made among flowers with a dead H. fulvohispidus, a dead beetle, a piece of plastic, and nothing (control flowers). Patrolling H. fulvohispidus more frequently visited flowers with a dead conspecific, a dead beetle, or a piece of plastic than the control flowers. Our experiment demonstrates that nectar-feeding insects (including conspecifics and other insects) enhance the flower-visiting frequency of patrolling H. fulvohispidus males on S. mertensiana flowers. Furthermore, we observed S. mertensiana pollen on patrolling males as well as females, suggesting that male bees may also function as pollen vectors.
Quality of life at the Dead Sea region: the lower the better? An observational study.
Avriel, Avital; Fuchs, Lior; Plakht, Ygal; Cicurel, Assi; Apfelbaum, Armando; Satran, Robert; Friger, Michael; Dartava, Dimitry; Sukenik, Shaul
2011-05-27
The Dead Sea region, the lowest in the world at 410 meters below sea level, is considered a potent climatotherapy center for the treatment of different chronic diseases. To assess the prevalence of chronic diseases and the quality of life of residents of the Dead Sea region compared with residents of the Ramat Negev region, which has a similar climate, but is situated 600 meters above sea level. An observational study based on a self-administered questionnaire. Data were collected from kibbutz (communal settlement) members in both regions. Residents of the Dead Sea were the study group and of Ramat Negev were the control group. We compared demographic characteristics, the prevalence of different chronic diseases and health-related quality of life (HRQOL) using the SF-36 questionnaire. There was a higher prevalence of skin nevi and non-inflammatory rheumatic diseases (NIRD) among Dead Sea residents, but they had significantly higher HRQOL mean scores in general health (68.7 ± 21 vs. 64.4 ± 22, p = 0.023) and vitality (64.7 ± 17.9 vs. 59.6 ± 17.3, p = 0.001), as well as significantly higher summary scores: physical component score (80.7 ± 18.2 vs. 78 ± 18.6, p = 0.042), and mental component score (79 ± 16.4 vs. 77.2 ± 15, p = 0.02). These results did not change after adjusting for social-demographic characteristics, health-related habits, and chronic diseases. No significant difference between the groups was found in the prevalence of most chronic diseases, except for higher rates of skin nevi and NIRD among Dead Sea residents. HRQOL was significantly higher among Dead Sea residents, both healthy or with chronic disease.
Minimally invasive estimation of ventricular dead space volume through use of Frank-Starling curves.
Davidson, Shaun; Pretty, Chris; Pironet, Antoine; Desaive, Thomas; Janssen, Nathalie; Lambermont, Bernard; Morimont, Philippe; Chase, J Geoffrey
2017-01-01
This paper develops a means of more easily and less invasively estimating ventricular dead space volume (Vd), an important, but difficult to measure physiological parameter. Vd represents a subject and condition dependent portion of measured ventricular volume that is not actively participating in ventricular function. It is employed in models based on the time varying elastance concept, which see widespread use in haemodynamic studies, and may have direct diagnostic use. The proposed method involves linear extrapolation of a Frank-Starling curve (stroke volume vs end-diastolic volume) and its end-systolic equivalent (stroke volume vs end-systolic volume), developed across normal clinical procedures such as recruitment manoeuvres, to their point of intersection with the y-axis (where stroke volume is 0) to determine Vd. To demonstrate the broad applicability of the method, it was validated across a cohort of six sedated and anaesthetised male Pietrain pigs, encompassing a variety of cardiac states from healthy baseline behaviour to circulatory failure due to septic shock induced by endotoxin infusion. Linear extrapolation of the curves was supported by strong linear correlation coefficients of R = 0.78 and R = 0.80 average for pre- and post- endotoxin infusion respectively, as well as good agreement between the two linearly extrapolated y-intercepts (Vd) for each subject (no more than 7.8% variation). Method validity was further supported by the physiologically reasonable Vd values produced, equivalent to 44.3-53.1% and 49.3-82.6% of baseline end-systolic volume before and after endotoxin infusion respectively. This method has the potential to allow Vd to be estimated without a particularly demanding, specialised protocol in an experimental environment. Further, due to the common use of both mechanical ventilation and recruitment manoeuvres in intensive care, this method, subject to the availability of multi-beat echocardiography, has the potential to allow for estimation of Vd in a clinical environment.
ERIC Educational Resources Information Center
So, Wing Chee; Chen-Hui, Colin Sim; Wei-Shan, Julie Low
2012-01-01
Abundant research has shown that encoding meaningful gesture, such as an iconic gesture, enhances memory. This paper asked whether gesture needs to carry meaning to improve memory recall by comparing the mnemonic effect of meaningful (i.e., iconic gestures) and nonmeaningful gestures (i.e., beat gestures). Beat gestures involve simple motoric…
Counting Melodies: Recursion through Music for a Liberal Arts Audience
ERIC Educational Resources Information Center
Ludwick, Kurt
2016-01-01
In the study of music from a mathematical perspective, several types of counting problems naturally arise. For example, how many different rhythms of a specified length (in beats) can be written if we restrict ourselves to only quarter notes (one beat) and half notes (two beats)? What if we allow whole notes, dotted half notes, etc.? Or, what if…
Single-photon superradiant beating from a Doppler-broadened ladder-type atomic ensemble
NASA Astrophysics Data System (ADS)
Lee, Yoon-Seok; Lee, Sang Min; Kim, Heonoh; Moon, Han Seb
2017-12-01
We report on heralded-single-photon superradiant beating in the spontaneous four-wave mixing process of Doppler-broadened ladder-type 87Rb atoms. When Doppler-broadened atoms contribute to two-photon coherence, the detection probability amplitudes of the heralded single photons are coherently superposed despite inhomogeneous broadened atomic media. Single-photon superradiant beating is observed, which constitutes evidence for the coherent superposition of two-photon amplitudes from different velocity classes in the Doppler-broadened atomic ensemble. We present a theoretical model in which the single-photon superradiant beating originates from the interference between wavelength-separated two-photon amplitudes via the reabsorption filtering effect.
Beliefs about wife beating: an exploratory study with Lebanese students.
Obeid, Nadine; Chang, Doris F; Ginges, Jeremy
2010-06-01
In recent years, there has been a growing interest in understanding the sociocultural contexts and risk factors for domestic violence in the Arab world. This study provides an analysis of the religious, legal, and familial contexts of domestic violence in Lebanon and assesses contemporary attitudes toward women and wife beating in a sample of 206 Lebanese university students. Gender, patriarchal attitudes, religion, childhood experiences with family violence, and mother's employment status were investigated as predictors of attitudes toward wife beating. Consistent with feminist theories of wife abuse, gender and attitudes toward women's roles emerged as the strongest predictors of beliefs about wife beating.
Measuring and characterizing beat phenomena with a smartphone
NASA Astrophysics Data System (ADS)
Osorio, M.; Pereyra, C. J.; Gau, D. L.; Laguarda, A.
2018-03-01
Nowadays, smartphones are in everyone’s life. Apart from being excellent tools for work and communication, they can also be used to perform several measurements of simple physical magnitudes, serving as a mobile and inexpensive laboratory, ideal for use physics lectures in high schools or universities. In this article, we use a smartphone to analyse the acoustic beat phenomena by using a simple experimental setup, which can complement lessons in the classroom. The beats were created by the superposition of the waves generated by two tuning forks, with their natural frequencies previously characterized using different applications. After the characterization, we recorded the beats and analysed the oscillations in time and frequency.
Visual suppression of the vestibulo-ocular reflex during space flight
NASA Technical Reports Server (NTRS)
Uri, John J.; Thornton, William E.; Moore, Thomas P.; Pool, Sam L.
1989-01-01
Visual suppression of the vestibulo-ocular reflex was studied in 16 subjects on 4 Space Shuttle missions. Eye movements were recorded by electro-oculography while subjects fixated a head mounted target during active sinusoidal head oscillation at 0.3 Hz. Adequacy of suppression was evaluated by the number of nystagmus beats, the mean amplitude of each beat, and the cumulative amplitude of nystagmus during two head oscillation cycles. Vestibulo-ocular reflex suppression was unaffected by space flight. Subjects with space motion sickness during flight had significantly more nystagmus beats than unaffected individuals. These susceptible subjects also tended to have more nystagmus beats before flight.
Exploring how musical rhythm entrains brain activity with electroencephalogram frequency-tagging.
Nozaradan, Sylvie
2014-12-19
The ability to perceive a regular beat in music and synchronize to this beat is a widespread human skill. Fundamental to musical behaviour, beat and meter refer to the perception of periodicities while listening to musical rhythms and often involve spontaneous entrainment to move on these periodicities. Here, we present a novel experimental approach inspired by the frequency-tagging approach to understand the perception and production of rhythmic inputs. This approach is illustrated here by recording the human electroencephalogram responses at beat and meter frequencies elicited in various contexts: mental imagery of meter, spontaneous induction of a beat from rhythmic patterns, multisensory integration and sensorimotor synchronization. Collectively, our observations support the view that entrainment and resonance phenomena subtend the processing of musical rhythms in the human brain. More generally, they highlight the potential of this approach to help us understand the link between the phenomenology of musical beat and meter and the bias towards periodicities arising under certain circumstances in the nervous system. Entrainment to music provides a highly valuable framework to explore general entrainment mechanisms as embodied in the human brain. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Study on mechanism of amplitude fluctuation of dual-frequency beat in microchip Nd:YAG laser
NASA Astrophysics Data System (ADS)
Chen, Hao; Tan, Yidong; Zhang, Shulian; Sun, Liqun
2017-01-01
In the laser heterodyne interferometry based on the microchip Nd:YAG dual-frequency laser, the amplitude of the beat note periodically fluctuates in time domain, which leads to the instability of the measurement. On the frequency spectrums of the two mono-frequency components of the laser and their beat note, several weak sideband signals are observed on both sides of the beat note. It is proved that the sideband frequencies are associated with the relaxation oscillation frequencies of the laser. The mechanism for the relaxation oscillations inducing the occurrence of the sideband signals is theoretically analyzed, and the quantitative relationship between the intensity ratio of the beat note to the sideband signal and the level of the amplitude fluctuation is simulated with the derived mathematical model. The results demonstrate that the periodical amplitude fluctuation of the beat note is actually induced by the relaxation oscillation. And the level of the amplitude fluctuation is lower than 10% when the intensity ratio is greater than 32 dB. These conclusions are beneficial to reduce the amplitude fluctuation of the microchip Nd:YAG dual-frequency laser and improve the stability of the heterodyne interferometry.
Prevalence and pattern of cardiac autonomic dysfunction in newly detected type 2 diabetes mellitus.
Jyotsna, Viveka P; Sahoo, Abhay; Sreenivas, V; Deepak, K K
2009-01-01
Cardiac autonomic functions were assessed in 145 consecutive recently detected type 2 diabetics. Ninety-nine healthy persons served as controls. Criteria for normalcy were, heart rate variation during deep breathing >or=15 beats/min, deep breathing expiratory to inspiratory R-R ratio >or=1.21, Valsalva ratio >or=1.21, sustained handgrip test >or=16 mm of mercury, cold pressor test >or=10, BP response to standing
Prospero, S; Conedera, M; Heiniger, U; Rigling, D
2006-12-01
ABSTRACT Sustainable biological control of the chestnut blight fungus Crypho-nectria parasitica with hypovirulence depends on the production and dissemination of hypovirus-infected propagules of the pathogen. We investigated the ability of C. parasitica to sporulate and produce hypo-virus-infected spores on recently dead chestnut wood in coppice stands in southern Switzerland where hypovirulence has been naturally established. The number and type (active, inactive, or none) of cankers was assessed on experimentally cut and stacked stems, firewood stacks, and natural dead wood. Hypovirus-free and hypovirus-infected strains readily survived for more than 1 year in the chestnut blight cankers of the stacked stems. Sporulation of C. parasitica was observed on the surface of preexisting inactive and active cankers, as well as on newly colonized bark areas and was significantly more abundant than on comparable cankers on living stems. On all types of dead wood, we observed more stromata with perithecia than with pycnidia; however, a large proportion of the stromata was not differentiated. All perithecia examined yielded only hypovirus-free ascospores. The incidence of pycnidia that produced hypovirus-infected conidia ranged from 5% on natural dead wood to 41% on the experimental stacks. The mean virus transmission rate into conidia was 69%. Our study demonstrates a considerable saprophytic activity of C. parasitica on recently dead chestnut wood and supports the hypothesis of a role of this saprophytic phase in the epidemiology of hypovirulence.
46 CFR 169.623 - Power-driven steering systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... systems must have means to be brought into operation from a dead ship condition, without external aid. The... steering systems from the main steering control location must include, as applicable— (1) Control of any...
46 CFR 169.623 - Power-driven steering systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... systems must have means to be brought into operation from a dead ship condition, without external aid. The... steering systems from the main steering control location must include, as applicable— (1) Control of any...
46 CFR 169.623 - Power-driven steering systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... systems must have means to be brought into operation from a dead ship condition, without external aid. The... steering systems from the main steering control location must include, as applicable— (1) Control of any...
Monitoring nocturnal heart rate with bed sensor.
Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M
2014-01-01
This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.
Emergence of flagellar beating from the collective behavior of individual ATP-powered dyneins
NASA Astrophysics Data System (ADS)
Namdeo, S.; Onck, P. R.
2016-10-01
Flagella are hair-like projections from the surface of eukaryotic cells, and they play an important role in many cellular functions, such as cell-motility. The beating of flagella is enabled by their internal architecture, the axoneme, and is powered by a dense distribution of motor proteins, dyneins. The dyneins deliver the required mechanical work through the hydrolysis of ATP. Although the dynein-ATP cycle, the axoneme microstructure, and the flagellar-beating kinematics are well studied, their integration into a coherent picture of ATP-powered flagellar beating is still lacking. Here we show that a time-delayed negative-work-based switching mechanism is able to convert the individual sliding action of hundreds of dyneins into a regular overall beating pattern leading to propulsion. We developed a computational model based on a minimal representation of the axoneme consisting of two representative doublet microtubules connected by nexin links. The relative sliding of the microtubules is incorporated by modeling two groups of ATP-powered dyneins, each responsible for sliding in opposite directions. A time-delayed switching mechanism is postulated, which is key in converting the local individual sliding action of multiple dyneins into global beating. Our results demonstrate that an overall nonreciprocal beating pattern can emerge with time due to the spatial and temporal coordination of the individual dyneins. These findings provide insights in the fundamental working mechanism of axonemal dyneins and could possibly open new research directions in the field of flagellar motility.
Emergence of flagellar beating from the collective behavior of individual ATP-powered dyneins.
Namdeo, S; Onck, P R
2016-10-01
Flagella are hair-like projections from the surface of eukaryotic cells, and they play an important role in many cellular functions, such as cell-motility. The beating of flagella is enabled by their internal architecture, the axoneme, and is powered by a dense distribution of motor proteins, dyneins. The dyneins deliver the required mechanical work through the hydrolysis of ATP. Although the dynein-ATP cycle, the axoneme microstructure, and the flagellar-beating kinematics are well studied, their integration into a coherent picture of ATP-powered flagellar beating is still lacking. Here we show that a time-delayed negative-work-based switching mechanism is able to convert the individual sliding action of hundreds of dyneins into a regular overall beating pattern leading to propulsion. We developed a computational model based on a minimal representation of the axoneme consisting of two representative doublet microtubules connected by nexin links. The relative sliding of the microtubules is incorporated by modeling two groups of ATP-powered dyneins, each responsible for sliding in opposite directions. A time-delayed switching mechanism is postulated, which is key in converting the local individual sliding action of multiple dyneins into global beating. Our results demonstrate that an overall nonreciprocal beating pattern can emerge with time due to the spatial and temporal coordination of the individual dyneins. These findings provide insights in the fundamental working mechanism of axonemal dyneins and could possibly open new research directions in the field of flagellar motility.
Van Leeuwen, Peter; Werner, Lisa; Hilal, Ziad; Schiermeier, Sven; Hatzmann, Wolfgang; Grönemeyer, Dietrich
2014-03-01
This study examines signal availability in fetal electrocardiogram (FECG) beat-to-beat acquisition and the accuracy of fetal heart rate variability (HRV) analysis in the clinical setting using a commercially available FECG monitor. Signal availability was examined in 130 FECG recordings of 0.3-17.5 h duration collected in 63 fetuses (25th-42nd week of gestation) under uncontrolled conditions. Identification of R-peaks demonstrated a signal loss of 30% ± 24% with 3.6 ± 1.7 signal gaps per minute. Median duration of the gaps within a recording was 1.8 ± 0.2 s. Per hour of recording, 1.8 ± 2.1 episodes of 5 min of uninterrupted data were found. Signal availability improved with gestational age and was poorer in women with high body-mass index. Fetal HRV between weeks 36-42 was examined on the basis of 5 min RR-interval episodes obtained under controlled quiet conditions in 55 FECG compared to 46 high quality fetal magnetocardiograms. There were no differences in RR-interval duration, its standard deviation and low frequency power. However, various measures of short-term HRV were significantly higher in the FECG data: root mean square of successive differences (10.0 ± 1.8 versus 6.6 ± 3.0 ms, p < 0.001, high frequency spectral power (24 ± 12 versus 13 ± 13 ms(2), p < 0.001) and approximate entropy (0.86 ± 0.16 versus 0.73 ± 0.24, p = 0.007). We conclude that, in spite of considerable signal loss, FECG recordings can accurately estimate heart rate and its overall variance. However, measures that quantify short-term beat-to-beat HRV will be compromised due to possible recurring inappropriate detection of single R-peaks.
Cholinergic stimulation with pyridostigmine protects against exercise induced myocardial ischaemia
Castro, R R T; Porphirio, G; Serra, S M; Nóbrega, A C L
2004-01-01
Objective: To determine the acute effects of pyridostigmine bromide, a reversible cholinesterase inhibitor, during exercise in patients with coronary artery disease. Design: Double blind, randomised, placebo controlled, crossover study. Setting: Outpatients evaluated in an exercise test laboratory. Patients: 15 patients with exercise induced myocardial ischaemia. Interventions: Maximal cardiopulmonary exercise test on a treadmill according to an individualised ramp protocol on three days. The first day was used for adaptation to the equipment and to determine exercise tolerance and the presence of exercise induced ischaemia. On the other two days, the cardiopulmonary exercise test was performed two hours after oral administration of pyridostigmine (45 mg) or placebo. All patients were taking their usual medication during the experiments. Main outcome measures: Rate–pressure product and oxygen uptake during exercise. Results: Pyridostigmine inhibited the submaximum chronotropic response (p = 0.001), delaying the onset of myocardial ischaemia, which occurred at a similar rate–pressure product (mean (SE) placebo 20.55 (1.08) mm Hg × beats/min 103; pyridostigmine 19.75 (1.28) mm Hg × beats/min 103; p = 0.27) but at a higher exercise intensity (oxygen consumption: placebo 18.6 (1.7) ml/kg/min; pyridostigmine 19.6 (1.8) ml/kg/min; p = 0.03). Also, pyridostigmine increased peak oxygen consumption (placebo 23.6 (2) ml/kg/min; pyridostigmine 24.8 (2) ml/kg/min; p = 0.01) and peak oxygen pulse (placebo 12.9 (1) ml/beat; pyridostigmine 13.6 (1) ml/beat; p = 0.02). Conclusions: Pyridostigmine improved peak exercise tolerance and inhibited the chronotropic response to submaximum exercise, increasing the intensity at which myocardial ischaemia occurred. These results suggest that pyridostigmine can protect against exercise induced myocardial ischaemia. PMID:15367503
[Effect of urapidil combined with phentolamine on hypertension during extracorporeal circulation].
Wang, Fangjun; Chen, Bin; Liu, Yang; Tu, Faping
2014-08-01
To study the effect of urapidil combined with phentolamine in the management of hypertension during extracorporeal circulation. Ninety patients undergoing aortic and mitral valve replacement were randomly divided into 3 equal groups to receive treatment with phentolamine (group A), urapidil (group B), or both (group C) during extracorporeal circulation. The mean arterial pressure (MAP) before and after drug administration, time interval of two administrations, spontaneous recovery of heart beat after aorta unclamping, ventricular arrhythmia, changes of ST-segment 1 min after the recovery of heart beat, ante-parallel cycle time, aorta clamping time, post-parallel cycle time, dopamine dose after cardiac resuscitation, and perioperative changes of plasma TNF-α and IL-6 levels were recorded. There was no significant difference in MAP between the 3 groups before or after hypotensive drug administration (P>0.05). The time interval of two hypotensive drug administrations was longer in group C than in groups A and B (P<0.05). The incidence of spontaneous recovery of heart beat after aorta unclamping, incidence of ventricular arrhythmia, changes of ST-segment 1 min after the recovery of heart beat, ante-parallel cycle time, aorta clamping time, and post-parallel cycle time were all comparable between the 3 groups. The dose of dopamine administered after cardiac resuscitation was significantly larger in group B than in groups A or group C (P<0.05). The plasma levels of TNF-α and IL-6 were significantly increased after CPB and after the operation in all the groups, but were lowed in group C than in groups A and B at the end of CPB and at 2 h and 12 after the operation. Urapidil combined with phentolamine can control hypertension during extracorporeal circulation without causing hypotension.
Dotov, D G; Bayard, S; Cochen de Cock, V; Geny, C; Driss, V; Garrigue, G; Bardy, B; Dalla Bella, S
2017-01-01
Rhythmic auditory cueing improves certain gait symptoms of Parkinson's disease (PD). Cues are typically stimuli or beats with a fixed inter-beat interval. We show that isochronous cueing has an unwanted side-effect in that it exacerbates one of the motor symptoms characteristic of advanced PD. Whereas the parameters of the stride cycle of healthy walkers and early patients possess a persistent correlation in time, or long-range correlation (LRC), isochronous cueing renders stride-to-stride variability random. Random stride cycle variability is also associated with reduced gait stability and lack of flexibility. To investigate how to prevent patients from acquiring a random stride cycle pattern, we tested rhythmic cueing which mimics the properties of variability found in healthy gait (biological variability). PD patients (n=19) and age-matched healthy participants (n=19) walked with three rhythmic cueing stimuli: isochronous, with random variability, and with biological variability (LRC). Synchronization was not instructed. The persistent correlation in gait was preserved only with stimuli with biological variability, equally for patients and controls (p's<0.05). In contrast, cueing with isochronous or randomly varying inter-stimulus/beat intervals removed the LRC in the stride cycle. Notably, the individual's tendency to synchronize steps with beats determined the amount of negative effects of isochronous and random cues (p's<0.05) but not the positive effect of biological variability. Stimulus variability and patients' propensity to synchronize play a critical role in fostering healthier gait dynamics during cueing. The beneficial effects of biological variability provide useful guidelines for improving existing cueing treatments. Copyright © 2016 Elsevier B.V. All rights reserved.
Al Haddad, Hani; Laursen, Paul B; Chollet, Didier; Lemaitre, Frédéric; Ahmaidi, Saïd; Buchheit, Martin
2010-08-25
This study aimed to investigate the effect of cold and thermoneutral water immersion on post-exercise parasympathetic reactivation, inferred from heart rate (HR) recovery (HRR) and HR variability (HRV) indices. Twelve men performed, on three separate occasions, an intermittent exercise bout (all-out 30-s Wingate test, 5 min seated recovery, followed by 5 min of submaximal running exercise), randomly followed by 5 min of passive (seated) recovery under either cold (CWI), thermoneutral water immersion (TWI) or control (CON) conditions. HRR indices (e.g., heart beats recovered in the first minute after exercise cessation, HRR(60)(s)) and vagal-related HRV indices (i.e., natural logarithm of the square root of the mean of the sum of the squares of differences between adjacent normal R-R intervals (Ln rMSSD)) were calculated for the three recovery conditions. HRR(60)(s) was faster in water immersion compared with CON conditions [30+/-9 beats min(-)(1) for CON vs. 43+/- 10 beats min(-)(1) for TWI (P=0.003) and 40+/-13 beats min(-)(1) for CWI (P=0.017)], while no difference was found between CWI and TWI (P=0.763). Ln rMSSD was higher in CWI (2.32+/-0.67 ms) compared with CON (1.98+/-0.74 ms, P=0.05) and TWI (2.01+/-0.61 ms, P=0.08; aES=1.07) conditions, with no difference between CON and TWI (P=0.964). Water immersion is a simple and efficient means of immediately triggering post-exercise parasympathetic activity, with colder immersion temperatures likely to be more effective at increasing parasympathetic activity. Copyright 2010 Elsevier B.V. All rights reserved.
Nasrullah, Muazzam; Muazzam, Sana; Khosa, Faisal; Khan, Muhammad Mobarak Hussain
2017-01-01
Child marriage (before 18 years) is widely prevalent in Pakistan, and disproportionately affects young girls in rural, low income and poorly-educated households. Our study aims to determine the association of child marriage and attitude towards wife beating among currently married Pakistani women aged 15-24 after controlling for social equity indicators (education, wealth index, rural residence). We limited the data from Pakistan Demographic and Health Survey, 2012-2013 to currently married women aged 15-24 years (n=2648). Five specified dichotomous variables indicating women's attitude towards wife beating (goes out without telling husband, neglects the children, argues with husband, refuses to have sex with husband, burns the food) were considered as outcome variables. The likelihood (OR and 95% CI) of each outcome variable for the child marriage group was estimated using logistic regression models. The prevalence of child marriage was significantly higher among women having no education and Balochi ethnicity, living in Khyber Pakhtunkhwa region and rural area, and belonging to the poorest quintile of wealth index. Women married as children compared with women married as adults were more likely to justify wife beating for all five specified reasons. However, these associations were lost when social equity indicators and national region of residence were adjusted in the regression models. Highly prevalent child marriage practice among women can be minimized by promoting education and providing economic opportunities in Pakistan. © The Author 2016. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
On the mechanism of transverse-mode beatings in a Fabry - Perot laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, N; Ledenev, V I
2010-06-23
The mechanism of emergence of fundamental-mode and first-mode beatings in the case of a step-wise increase in the pump rate is studied under the stationary single-mode lasing conditions. Investigation is based on the numerical solution of nonstationary wave equations in a resonator in the quasi-optic approximation and on the equation for a relaxation-type medium as well as on the use of the first two Hermite - Gaussian polynomials {psi}{sub 0,1}(x) to obtain the distribution projections I{sub 0,1}(t), g{sub 0,1}(t) of the radiation intensity and gain, respectively. It is shown that the transverse-mode beatings emerge at early stages of two-mode lasing,more » the appearance of radiation intensity oscillations in the active medium preceding the development of the gain oscillations. The time of the passage of two-mode lasing to the stationary regime is determined. The phase shift {pi}/2 between the oscillations I{sub 1}(t) and g{sub 1}(t) is found for the established beating regime and the modulation depth {Delta}I averaged over the output aperture of the radiation intensity in the established two-mode regime is shown to be proportional to the pump rate excess k over the single-mode lasing threshold. A scheme for controlling the mode composition of laser radiation is proposed, which is based on the rules for determining I{sub 0,1}(t) by the sensor signals. The efficiency of the scheme is studied. The scheme employs two field intensity sensors mounted inside the resonator behind the output aperture. (resonators. modes)« less
Martínez-Alanis, Marisol; Ruiz-Velasco, Silvia; Lerma, Claudia
2016-12-15
Most approaches to predict ventricular tachyarrhythmias which are based on RR intervals consider only sinus beats, excluding premature ventricular complexes (PVCs). The method known as heartprint, which analyses PVCs and their characteristics, has prognostic value for fatal arrhythmias on long recordings of RR intervals (>70,000 beats). To evaluate characteristics of PVCs from short term recordings (around 1000 beats) and their prognostic value for imminent sustained tachyarrhythmia. We analyzed 132 pairs of short term RR interval recordings (one before tachyarrhythmia and one control) obtained from 78 patients. Patients were classified into two groups based on the history of accelerated heart rate (HR) (HR>90bpm) before a tachyarrhythmia episode. Heartprint indexes, such as mean coupling interval (meanCI) and the number of occurrences of the most prevalent form of PVCs (SNIB) were calculated. The predictive value of all the indexes and of the combination of different indexes was calculated. MeanCI shorter than 482ms and the occurrence of more repetitive arrhythmias (sNIB≥2.5), had a significant prognostic value for patients with accelerated heart rate: adjusted odds ratio of 2.63 (1.33-5.17) for meanCI and 2.28 (1.20-4.33) for sNIB. Combining these indexes increases the adjusted odds ratio: 10.94 (3.89-30.80). High prevalence of repeating forms of PVCs and shorter CI are potentially useful risk markers of imminent ventricular tachyarrhythmia. Knowing if a patient has history of VT/VF preceded by accelerated HR, improves the prognostic value of these risk markers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Sympathetic baroreflex gain in normotensive pregnant women
Usselman, Charlotte W.; Skow, Rachel J.; Matenchuk, Brittany A.; Chari, Radha S.; Julian, Colleen G.; Stickland, Michael K.; Davenport, Margie H.
2015-01-01
Muscle sympathetic nerve activity is increased during normotensive pregnancy while mean arterial pressure is maintained or reduced, suggesting baroreflex resetting. We hypothesized spontaneous sympathetic baroreflex gain would be reduced in normotensive pregnant women relative to nonpregnant matched controls. Integrated muscle sympathetic burst incidence and total sympathetic activity (microneurography), blood pressure (Finometer), and R-R interval (ECG) were assessed at rest in 11 pregnant women (33 ± 1 wk gestation, 31 ± 1 yr, prepregnancy BMI: 23.5 ± 0.9 kg/m2) and 11 nonpregnant controls (29 ± 1 yr; BMI: 25.2 ± 1.7 kg/m2). Pregnant women had elevated baseline sympathetic burst incidence (43 ± 2 vs. 33 ± 2 bursts/100 heart beats, P = 0.01) and total sympathetic activity (1,811 ± 148 vs. 1,140 ± 55 au, P < 0.01) relative to controls. Both mean (88 ± 3 vs. 91 ± 2 mmHg, P = 0.4) and diastolic (DBP) (72 ± 3 vs. 73 ± 2 mmHg, P = 0.7) pressures were similar between pregnant and nonpregnant women, respectively, indicating an upward resetting of the baroreflex set point with pregnancy. Baroreflex gain, calculated as the linear relationship between sympathetic burst incidence and DBP, was reduced in pregnant women relative to controls (−3.7 ± 0.5 vs. −5.4 ± 0.5 bursts·100 heart beats−1·mmHg−1, P = 0.03), as was baroreflex gain calculated with total sympathetic activity (−294 ± 24 vs. −210 ± 24 au·100 heart beats−1·mmHg−1; P = 0.03). Cardiovagal baroreflex gain (sequence method) was not different between nonpregnant controls and pregnant women (49 ± 8 vs. 36 ± 8 ms/mmHg; P = 0.2). However, sympathetic (burst incidence) and cardiovagal gains were negatively correlated in pregnant women (R = −0.7; P = 0.02). Together, these data indicate that the influence of the sympathetic nervous system over arterial blood pressure is reduced in normotensive pregnancy, in terms of both long-term and beat-to-beat regulation of arterial pressure, likely through a baroreceptor-dependent mechanism. PMID:26139215
ERIC Educational Resources Information Center
Dhaher, Enas A.; Mikolajczyk, Rafael T.; Maxwell, Annette E.; Kramer, Alexander
2010-01-01
A total of 450 women were interviewed in Mother and Child Health Care Centers in three cities in West Bank, Palestine, to assess attitudes toward wife beating. Overall, women perceived wife beating to be justified if a wife insults her husband (59%), if she disobeys her husband (49%), if she neglects her children (37%), if she goes out without…
Multifractality in Cardiac Dynamics
NASA Astrophysics Data System (ADS)
Ivanov, Plamen Ch.; Rosenblum, Misha; Stanley, H. Eugene; Havlin, Shlomo; Goldberger, Ary
1997-03-01
Wavelet decomposition is used to analyze the fractal scaling properties of heart beat time series. The singularity spectrum D(h) of the variations in the beat-to-beat intervals is obtained from the wavelet transform modulus maxima which contain information on the hierarchical distribution of the singularities in the signal. Multifractal behavior is observed for healthy cardiac dynamics while pathologies are associated with loss of support in the singularity spectrum.
NASA Technical Reports Server (NTRS)
Nakatani, S.; Thomas, J. D.; Vandervoort, P. M.; Zhou, J.; Greenberg, N. L.; Savage, R. M.; McCarthy, P. M.
1997-01-01
OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.
NASA Astrophysics Data System (ADS)
Genoud, Adrien P.; Basistyy, Roman; Williams, Gregory M.; Thomas, Benjamin P.
2018-03-01
Mosquito-borne diseases are a major challenge for Human health as they affect nearly 700 million people every year and result in over 1 million deaths. Reliable information on the evolution of population and spatial distribution of key insects species is of major importance in the development of eco-epidemiologic models. This paper reports on the remote characterization of flying mosquitoes using a continuous-wave infrared optical remote sensing system. The system is setup in a controlled environment to mimic long-range lidars, mosquitoes are free flying at a distance of 4 m from the collecting optics. The wing beat frequency is retrieved from the backscattered light from mosquitoes transiting through the laser beam. A total of 427 transit signals have been recorded from three mosquito species, males and females. Since the mosquito species and gender are known a priori, we investigate the use of wing beat frequency as the sole predictor variable for two Bayesian classifications: gender alone (two classes) and species/gender (six classes). The gender of each mosquito is retrieved with a 96.5% accuracy while the species/gender of mosquitoes is retrieved with a 62.3% accuracy. Known to be an efficient mean to identify insect family, we discuss the limitations of using wing beat frequency alone to identify insect species.
Hoyer, Dirk; Leder, Uwe; Hoyer, Heike; Pompe, Bernd; Sommer, Michael; Zwiener, Ulrich
2002-01-01
The heart rate variability (HRV) is related to several mechanisms of the complex autonomic functioning such as respiratory heart rate modulation and phase dependencies between heart beat cycles and breathing cycles. The underlying processes are basically nonlinear. In order to understand and quantitatively assess those physiological interactions an adequate coupling analysis is necessary. We hypothesized that nonlinear measures of HRV and cardiorespiratory interdependencies are superior to the standard HRV measures in classifying patients after acute myocardial infarction. We introduced mutual information measures which provide access to nonlinear interdependencies as counterpart to the classically linear correlation analysis. The nonlinear statistical autodependencies of HRV were quantified by auto mutual information, the respiratory heart rate modulation by cardiorespiratory cross mutual information, respectively. The phase interdependencies between heart beat cycles and breathing cycles were assessed basing on the histograms of the frequency ratios of the instantaneous heart beat and respiratory cycles. Furthermore, the relative duration of phase synchronized intervals was acquired. We investigated 39 patients after acute myocardial infarction versus 24 controls. The discrimination of these groups was improved by cardiorespiratory cross mutual information measures and phase interdependencies measures in comparison to the linear standard HRV measures. This result was statistically confirmed by means of logistic regression models of particular variable subsets and their receiver operating characteristics.
Zhao, Weihong; Zhu, Qian; Yan, Mingxing; Li, Cheng; Yuan, Jiangjing; Qin, Guojuan; Zhang, Jian
2015-02-01
Levonorgestrel, a derivative of progesterone, effectively protects women against unwanted pregnancy as an emergency contraceptive. Previous studies have not been successful in determining the mechanism by which levonorgestrel acts. In the present study we analysed cilia beat action and cilia morphology following levonorgestrel exposure in vitro and in vivo using both light and electron microscopy. There was a significant decrease in the ciliary beat frequency (CBF) of human fallopian tubes between mucosal explants bathed in 5 μmol/L levonorgestrel and those bathed in medium alone (P < 0.05). There was a tendency for CBF to decrease more in the ampulla than in isthmus, but there were no differences between the proliferative and secretory phases. In rat oviducts, levonorgestrel produced a similar reduction in CBF (~ 10%) compared with the saline control group (P < 0.05). Histological and ultrastructural analysis demonstrated no changes in the percentage of ciliated cells or in the classic '9 + 2' structure of cilia following levonorgestrel treatment in either system. Thus, levonorgestrel reduces CBF without damaging cilia morphology. Decreases in CBF may indicate a pathological role for levonorgestrel in the transportation of the ovum and zygote in the fallopian tube. © 2014 Wiley Publishing Asia Pty Ltd.
Garjani, A; Nazemiyeh, H; Maleki, N; Valizadeh, H
2000-09-01
Different species of Crataegus, commonly called Hawthorn, were reported to possess wide pharmacological effects on the cardiovascular system. In the present study, chloroform, ethylacetate and methanol (70%) extracts of the flowering tops of Crataegus meyeri A. Pojark. were studied. The extracts were tested on the incidence and severity of arrhythmias induced by a period of myocardial ischaemia in open-chest anaesthetized male Wistar rats. Infusion of a hydroalcohol extract (1 mg/kg/min) resulted in a significant decrease in the total number of ventricular ectopic beats (from 1494 +/- 362 in the control to 634 +/- 102), mainly by reduction of beats occurring as ventricular tachycardia. A chloroform extract (1 mg/kg/min) also reduced the total number of ventricular ectopic beats but this reduction was due to the decrease of single extrasystoles. A significant reduction in the time spent for ventricular fibrillation was seen by the hydroalcohol and ethylacetate extracts. There were no significant changes in the heart rate and blood pressure during the extract infusion. However, bolus injection of all the extracts caused a significant reduction in the blood pressure. Thus, the extracts of Crataegus meyeri have a hypotensive and a potential antiarrhythmic action on ischaemic myocardium and may possess active principles. Copyright 2000 John Wiley & Sons, Ltd.
Intermittent balneotherapy at the Dead Sea area for patients with knee osteoarthritis.
Sherman, Gilad; Zeller, Lior; Avriel, Avital; Friger, Michael; Harari, Marco; Sukenik, Shaul
2009-02-01
Balneotherapy, traditionally administered during a continuous stay at the Dead Sea area, has been shown to be effective for patients suffering from knee osteoarthritis. To evaluate the effectiveness of an intermittent regimen of balneotherapy at the Dead Sea for patients with knee osteoarthritis. Forty-four patients with knee osteoarthritis were included in a prospective randomized single-blind controlled study. The patients were divided into two groups: a treatment group (n=24), which were treated twice weekly for 6 consecutive weeks in a sulfur pool heated to 35-36 degrees C, and a control group (n=20) treated in a Jacuzzi filled with tap water heated to 35-36 degrees C. Participants were assessed by the Lequesne index of osteoarthritis severity, the WOMAC index, the SF-36 quality of health questionnaire, VAS scales for pain (completed by patients and physicians), and physical examination. A statistically significant improvement, lasting up to 6 months, was observed in the treatment group for most of the clinical parameters. In the control group the only improvements were in the SF-36 bodily pain scale at 6 months, the Lequesne index at 1 month and the WOMAC pain score at the end of the treatment period. Although the patients in the control group had milder disease, the difference between the two groups was not statistically significant. Intermittent balneotherapy appears to be effective for patients with knee osteoarthritis.
Pan, Fan; He, Peiyu; Liu, Chengyu; Li, Taiyong; Murray, Alan; Zheng, Dingchang
2017-11-01
Korotkoff sounds are known to change their characteristics during blood pressure (BP) measurement, resulting in some uncertainties for systolic and diastolic pressure (SBP and DBP) determinations. The aim of this study was to assess the variation of Korotkoff sounds during BP measurement by examining all stethoscope sounds associated with each heartbeat from above systole to below diastole during linear cuff deflation. Three repeat BP measurements were taken from 140 healthy subjects (age 21 to 73 years; 62 female and 78 male) by a trained observer, giving 420 measurements. During the BP measurements, the cuff pressure and stethoscope signals were simultaneously recorded digitally to a computer for subsequent analysis. Heartbeats were identified from the oscillometric cuff pressure pulses. The presence of each beat was used to create a time window (1 s, 2000 samples) centered on the oscillometric pulse peak for extracting beat-by-beat stethoscope sounds. A time-frequency two-dimensional matrix was obtained for the stethoscope sounds associated with each beat, and all beats between the manually determined SBPs and DBPs were labeled as "Korotkoff." A convolutional neural network was then used to analyze consistency in sound patterns that were associated with Korotkoff sounds. A 10-fold cross-validation strategy was applied to the stethoscope sounds from all 140 subjects, with the data from ten groups of 14 subjects being analyzed separately, allowing consistency to be evaluated between groups. Next, within-subject variation of the Korotkoff sounds analyzed from the three repeats was quantified, separately for each stethoscope sound beat. There was consistency between folds with no significant differences between groups of 14 subjects (P = 0.09 to P = 0.62). Our results showed that 80.7% beats at SBP and 69.5% at DBP were analyzed as Korotkoff sounds, with significant differences between adjacent beats at systole (13.1%, P = 0.001) and diastole (17.4%, P < 0.001). Results reached stability for SBP (97.8%, at sixth beat below SBP) and DBP (98.1%, at sixth beat above DBP) with no significant differences between adjacent beats (SBP P = 0.74; DBP P = 0.88). There were no significant differences at high-cuff pressures, but at low pressures close to diastole there was a small difference (3.3%, P = 0.02). In addition, greater within subject variability was observed at SBP (21.4%) and DBP (28.9%), with a significant difference between both (P < 0.02). In conclusion, this study has demonstrated that Korotkoff sounds can be consistently identified during the period below SBP and above DBP, but that at systole and diastole there can be substantial variations that are associated with high variation in the three repeat measurements in each subject.
Design of push-pull system to control diesel particular matter inside a dead-end entry.
Zheng, Yi; Thiruvengadam, Magesh; Lan, Hai; Tien, Jerry C
Diesel particulate matter (DPM) is considered to be carcinogenic after prolonged exposure. With more diesel-powered equipment used in underground mines, miners' exposure to DPM has become an increasing concern. This paper used computational fluid dynamics method to study the DPM dispersion in a dead-end entry with loading operation. The effects of different push-pull ventilation systems on DPM distribution were evaluated to improve the working conditions for underground miners. The four push-pull systems considered include: long push and short pull tubing; short push and long pull tubing, long push and curved pull tubing, and short push and curved pull tubing. A species transport model with buoyancy effect was used to examine the DPM dispersion pattern with unsteady state analysis. During the 200 s of loading operation, high DPM levels were identified in the face and dead-end entry regions. This study can be used for mining engineer as guidance to design and setup local ventilation, select DPM control strategies and for DPM annual training for underground miners.
Ventricular beat classifier using fractal number clustering.
Bakardjian, H
1992-09-01
A two-stage ventricular beat 'associative' classification procedure is described. The first stage separates typical beats from extrasystoles on the basis of area and polarity rules. At the second stage, the extrasystoles are classified in self-organised cluster formations of adjacent shape parameter values. This approach avoids the use of threshold values for discrimination between ectopic beats of different shapes, which could be critical in borderline cases. A pattern shape feature conventionally called a 'fractal number', in combination with a polarity attribute, was found to be a good criterion for waveform evaluation. An additional advantage of this pattern classification method is its good computational efficiency, which affords the opportunity to implement it in real-time systems.
The automated counting of beating rates in individual cultured heart cells.
Collins, G A; Dower, R; Walker, M J
1981-12-01
The effect of drugs on the beating rate of cultured heart cells can be monitored in a number of ways. The simultaneous automated measurement of beating rates of a number of cells allows drug effects to be rapidly quantified. A photoresistive detector placed on a television image of a cell, when coupled to operational amplifiers, gives binary signals that can be processed by a microprocessor. On this basis, we have devised a system that is capable of simultaneously monitoring the individual beating of six single cultured heart cells. A microprocessor automatically processes data obtained under different experimental conditions and records it in suitable descriptive formats such as dose-response curves and double reciprocal plots.
Adler, D; Mahler, Y
1980-04-01
A procedure for automatic detection and digital processing of the maximum first derivative of the intraventricular pressure (dp/dtmax), time to dp/dtmax(t - dp/dt) and beat-to-beat intervals have been developed. The procedure integrates simple electronic circuits with a short program using a simple algorithm for the detection of the points of interest. The tasks of differentiating the pressure signal and detecting the onset of contraction were done by electronics, while the tasks of finding the values of dp/dtmax, t - dp/dt, beat-to-beat intervals and all computations needed were done by software. Software/hardware 'trade off' considerations and the accuracy and reliability of the system are discussed.
Tuning rules for robust FOPID controllers based on multi-objective optimization with FOPDT models.
Sánchez, Helem Sabina; Padula, Fabrizio; Visioli, Antonio; Vilanova, Ramon
2017-01-01
In this paper a set of optimally balanced tuning rules for fractional-order proportional-integral-derivative controllers is proposed. The control problem of minimizing at once the integrated absolute error for both the set-point and the load disturbance responses is addressed. The control problem is stated as a multi-objective optimization problem where a first-order-plus-dead-time process model subject to a robustness, maximum sensitivity based, constraint has been considered. A set of Pareto optimal solutions is obtained for different normalized dead times and then the optimal balance between the competing objectives is obtained by choosing the Nash solution among the Pareto-optimal ones. A curve fitting procedure has then been applied in order to generate suitable tuning rules. Several simulation results show the effectiveness of the proposed approach. Copyright © 2016. Published by Elsevier Ltd.
Observed-Based Adaptive Fuzzy Tracking Control for Switched Nonlinear Systems With Dead-Zone.
Tong, Shaocheng; Sui, Shuai; Li, Yongming
2015-12-01
In this paper, the problem of adaptive fuzzy output-feedback control is investigated for a class of uncertain switched nonlinear systems in strict-feedback form. The considered switched systems contain unknown nonlinearities, dead-zone, and immeasurable states. Fuzzy logic systems are utilized to approximate the unknown nonlinear functions, a switched fuzzy state observer is designed and thus the immeasurable states are obtained by it. By applying the adaptive backstepping design principle and the average dwell time method, an adaptive fuzzy output-feedback tracking control approach is developed. It is proved that the proposed control approach can guarantee that all the variables in the closed-loop system are bounded under a class of switching signals with average dwell time, and also that the system output can track a given reference signal as closely as possible. The simulation results are given to check the effectiveness of the proposed approach.
The Roles of Traditional Gender Myths and Beliefs About Beating on Self-Reported Partner Violence.
Husnu, Shenel; Mertan, Biran E
2015-08-24
The aim of the current study was to investigate the roles of beliefs about beating, traditional gender myth endorsement, ambivalent sexism, and perceived partner violence in determining an individual's own reported violence toward his or her partner. The sample consisted of 205 (117 women; 88 men) Turkish and Turkish Cypriot undergraduate students, aged between 16 and 29 years. Participants completed measures of beliefs about beating, traditional gender myth endorsement, and ambivalent sexism and rated the extent to which they experienced abusive behaviors from their partner as well as the extent to which they were themselves abusive to their partners. Results showed that positive beliefs about beating, endorsing traditional gender myths, and experiencing partner abuse were all predictive of self-reported abuse to one's partner. Furthermore, the relationship between myth endorsement and self-abusive behavior was mediated by beliefs toward beating-only in men. Results are discussed in light of the traditional gender system evident in Turkish societal makeup. © The Author(s) 2015.
Li, Hanqing; Watson, Ash; Olechwier, Agnieszka; Anaya, Michael; Sorooshyari, Siamak K; Harnett, Dermott P; Lee, Hyung-Kook (Peter); Vielmetter, Jost; Fares, Mario A; Garcia, K Christopher; Özkan, Engin
2017-01-01
An ‘interactome’ screen of all Drosophila cell-surface and secreted proteins containing immunoglobulin superfamily (IgSF) domains discovered a network formed by paralogs of Beaten Path (Beat) and Sidestep (Side), a ligand-receptor pair that is central to motor axon guidance. Here we describe a new method for interactome screening, the Bio-Plex Interactome Assay (BPIA), which allows identification of many interactions in a single sample. Using the BPIA, we ‘deorphanized’ four more members of the Beat-Side network. We confirmed interactions using surface plasmon resonance. The expression patterns of beat and side genes suggest that Beats are neuronal receptors for Sides expressed on peripheral tissues. side-VI is expressed in muscle fibers targeted by the ISNb nerve, as well as at growth cone choice points and synaptic targets for the ISN and TN nerves. beat-V genes, encoding Side-VI receptors, are expressed in ISNb and ISN motor neurons. PMID:28829740
HEART: an automated beat-to-beat cardiovascular analysis package using Matlab.
Schroeder, M J Mark J; Perreault, Bill; Ewert, D L Daniel L; Koenig, S C Steven C
2004-07-01
A computer program is described for beat-to-beat analysis of cardiovascular parameters from high-fidelity pressure and flow waveforms. The Hemodynamic Estimation and Analysis Research Tool (HEART) is a post-processing analysis software package developed in Matlab that enables scientists and clinicians to document, load, view, calibrate, and analyze experimental data that have been digitally saved in ascii or binary format. Analysis routines include traditional hemodynamic parameter estimates as well as more sophisticated analyses such as lumped arterial model parameter estimation and vascular impedance frequency spectra. Cardiovascular parameter values of all analyzed beats can be viewed and statistically analyzed. An attractive feature of the HEART program is the ability to analyze data with visual quality assurance throughout the process, thus establishing a framework toward which Good Laboratory Practice (GLP) compliance can be obtained. Additionally, the development of HEART on the Matlab platform provides users with the flexibility to adapt or create study specific analysis files according to their specific needs. Copyright 2003 Elsevier Ltd.
Asymmetrically localized proteins stabilize basal bodies against ciliary beating forces
Galati, Domenico F.
2016-01-01
Basal bodies are radially symmetric, microtubule-rich structures that nucleate and anchor motile cilia. Ciliary beating produces asymmetric mechanical forces that are resisted by basal bodies. To resist these forces, distinct regions within the basal body ultrastructure and the microtubules themselves must be stable. However, the molecular components that stabilize basal bodies remain poorly defined. Here, we determine that Fop1 functionally interacts with the established basal body stability components Bld10 and Poc1. We find that Fop1 and microtubule glutamylation incorporate into basal bodies at distinct stages of assembly, culminating in their asymmetric enrichment at specific triplet microtubule regions that are predicted to experience the greatest mechanical force from ciliary beating. Both Fop1 and microtubule glutamylation are required to stabilize basal bodies against ciliary beating forces. Our studies reveal that microtubule glutamylation and Bld10, Poc1, and Fop1 stabilize basal bodies against the forces produced by ciliary beating via distinct yet interdependent mechanisms. PMID:27807131
The ability to tap to a beat relates to cognitive, linguistic, and perceptual skills
Tierney, Adam T.; Kraus, Nina
2013-01-01
Reading-impaired children have difficulty tapping to a beat. Here we tested whether this relationship between reading ability and synchronized tapping holds in typically-developing adolescents. We also hypothesized that tapping relates to two other abilities. First, since auditory-motor synchronization requires monitoring of the relationship between motor output and auditory input, we predicted that subjects better able to tap to the beat would perform better on attention tests. Second, since auditory-motor synchronization requires fine temporal precision within the auditory system for the extraction of a sound’s onset time, we predicted that subjects better able to tap to the beat would be less affected by backward masking, a measure of temporal precision within the auditory system. As predicted, tapping performance related to reading, attention, and backward masking. These results motivate future research investigating whether beat synchronization training can improve not only reading ability, but potentially executive function and basic auditory processing as well. PMID:23400117
Experimental Study on Effective Cure of "Tsumari" Phenomenon.
ERIC Educational Resources Information Center
Mito, Hiromichi
1999-01-01
Examines an effective method of curing tsumari, a phenomenon whereby the first note in a sequence of two eighth-notes is performed shorter than the second note. Considers two possible causes: (1) insufficient motor skill control and (2) a lack of steady beat perception. Reveals a reduction in tsumari after procedural instruction. (CMK)
Bubble measuring instrument and method
NASA Technical Reports Server (NTRS)
Magari, Patrick J. (Inventor); Kline-Schoder, Robert (Inventor)
2003-01-01
Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.
Ariane, Mostapha; Kassinos, Stavros; Velaga, Sitaram; Alexiadis, Alessio
2018-04-01
In this paper, the mass transfer coefficient (permeability) of boundary layers containing motile cilia is investigated by means of discrete multi-physics. The idea is to understand the main mechanisms of mass transport occurring in a ciliated-layer; one specific application being inhaled drugs in the respiratory epithelium. The effect of drug diffusivity, cilia beat frequency and cilia flexibility is studied. Our results show the existence of three mass transfer regimes. A low frequency regime, which we called shielding regime, where the presence of the cilia hinders mass transport; an intermediate frequency regime, which we have called diffusive regime, where diffusion is the controlling mechanism; and a high frequency regime, which we have called convective regime, where the degree of bending of the cilia seems to be the most important factor controlling mass transfer in the ciliated-layer. Since the flexibility of the cilia and the frequency of the beat changes with age and health conditions, the knowledge of these three regimes allows prediction of how mass transfer varies with these factors. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bubble Measuring Instrument and Method
NASA Technical Reports Server (NTRS)
Kline-Schoder, Robert (Inventor); Magari, Patrick J. (Inventor)
2002-01-01
Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.
Microscopic artificial swimmers
NASA Astrophysics Data System (ADS)
Dreyfus, Rémi; Baudry, Jean; Roper, Marcus L.; Fermigier, Marc; Stone, Howard A.; Bibette, Jérôme
2005-10-01
Microorganisms such as bacteria and many eukaryotic cells propel themselves with hair-like structures known as flagella, which can exhibit a variety of structures and movement patterns. For example, bacterial flagella are helically shaped and driven at their bases by a reversible rotary engine, which rotates the attached flagellum to give a motion similar to that of a corkscrew. In contrast, eukaryotic cells use flagella that resemble elastic rods and exhibit a beating motion: internally generated stresses give rise to a series of bends that propagate towards the tip. In contrast to this variety of swimming strategies encountered in nature, a controlled swimming motion of artificial micrometre-sized structures has not yet been realized. Here we show that a linear chain of colloidal magnetic particles linked by DNA and attached to a red blood cell can act as a flexible artificial flagellum. The filament aligns with an external uniform magnetic field and is readily actuated by oscillating a transverse field. We find that the actuation induces a beating pattern that propels the structure, and that the external fields can be adjusted to control the velocity and the direction of motion.