Sample records for decision support cds

  1. Development and evaluation of a comprehensive clinical decision support taxonomy: comparison of front-end tools in commercial and internally developed electronic health record systems

    PubMed Central

    Sittig, Dean F; Ash, Joan S; Feblowitz, Joshua; Meltzer, Seth; McMullen, Carmit; Guappone, Ken; Carpenter, Jim; Richardson, Joshua; Simonaitis, Linas; Evans, R Scott; Nichol, W Paul; Middleton, Blackford

    2011-01-01

    Background Clinical decision support (CDS) is a valuable tool for improving healthcare quality and lowering costs. However, there is no comprehensive taxonomy of types of CDS and there has been limited research on the availability of various CDS tools across current electronic health record (EHR) systems. Objective To develop and validate a taxonomy of front-end CDS tools and to assess support for these tools in major commercial and internally developed EHRs. Study design and methods We used a modified Delphi approach with a panel of 11 decision support experts to develop a taxonomy of 53 front-end CDS tools. Based on this taxonomy, a survey on CDS tools was sent to a purposive sample of commercial EHR vendors (n=9) and leading healthcare institutions with internally developed state-of-the-art EHRs (n=4). Results Responses were received from all healthcare institutions and 7 of 9 EHR vendors (response rate: 85%). All 53 types of CDS tools identified in the taxonomy were found in at least one surveyed EHR system, but only 8 functions were present in all EHRs. Medication dosing support and order facilitators were the most commonly available classes of decision support, while expert systems (eg, diagnostic decision support, ventilator management suggestions) were the least common. Conclusion We developed and validated a comprehensive taxonomy of front-end CDS tools. A subsequent survey of commercial EHR vendors and leading healthcare institutions revealed a small core set of common CDS tools, but identified significant variability in the remainder of clinical decision support content. PMID:21415065

  2. Reducing Diagnostic Error with Computer-Based Clinical Decision Support

    ERIC Educational Resources Information Center

    Greenes, Robert A.

    2009-01-01

    Information technology approaches to delivering diagnostic clinical decision support (CDS) are the subject of the papers to follow in the proceedings. These will address the history of CDS and present day approaches (Miller), evaluation of diagnostic CDS methods (Friedman), and the role of clinical documentation in supporting diagnostic decision…

  3. Intraoperative Clinical Decision Support for Anesthesia: A Narrative Review of Available Systems.

    PubMed

    Nair, Bala G; Gabel, Eilon; Hofer, Ira; Schwid, Howard A; Cannesson, Maxime

    2017-02-01

    With increasing adoption of anesthesia information management systems (AIMS), there is growing interest in utilizing AIMS data for intraoperative clinical decision support (CDS). CDS for anesthesia has the potential for improving quality of care, patient safety, billing, and compliance. Intraoperative CDS can range from passive and post hoc systems to active real-time systems that can detect ongoing clinical issues and deviations from best practice care. Real-time CDS holds the most promise because real-time alerts and guidance can drive provider behavior toward evidence-based standardized care during the ongoing case. In this review, we describe the different types of intraoperative CDS systems with specific emphasis on real-time systems. The technical considerations in developing and implementing real-time CDS are systematically covered. This includes the functional modules of a CDS system, development and execution of decision rules, and modalities to alert anesthesia providers concerning clinical issues. We also describe the regulatory aspects that affect development, implementation, and use of intraoperative CDS. Methods and measures to assess the effectiveness of intraoperative CDS are discussed. Last, we outline areas of future development of intraoperative CDS, particularly the possibility of providing predictive and prescriptive decision support.

  4. Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

    PubMed

    Kawamoto, Kensaku; Lobach, David F

    2007-01-01

    Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

  5. Enabling Cross-Platform Clinical Decision Support through Web-Based Decision Support in Commercial Electronic Health Record Systems: Proposal and Evaluation of Initial Prototype Implementations

    PubMed Central

    Zhang, Mingyuan; Velasco, Ferdinand T.; Musser, R. Clayton; Kawamoto, Kensaku

    2013-01-01

    Enabling clinical decision support (CDS) across multiple electronic health record (EHR) systems has been a desired but largely unattained aim of clinical informatics, especially in commercial EHR systems. A potential opportunity for enabling such scalable CDS is to leverage vendor-supported, Web-based CDS development platforms along with vendor-supported application programming interfaces (APIs). Here, we propose a potential staged approach for enabling such scalable CDS, starting with the use of custom EHR APIs and moving towards standardized EHR APIs to facilitate interoperability. We analyzed three commercial EHR systems for their capabilities to support the proposed approach, and we implemented prototypes in all three systems. Based on these analyses and prototype implementations, we conclude that the approach proposed is feasible, already supported by several major commercial EHR vendors, and potentially capable of enabling cross-platform CDS at scale. PMID:24551426

  6. Comparison of Computer-based Clinical Decision Support Systems and Content for Diabetes Mellitus.

    PubMed

    Kantor, M; Wright, A; Burton, M; Fraser, G; Krall, M; Maviglia, S; Mohammed-Rajput, N; Simonaitis, L; Sonnenberg, F; Middleton, B

    2011-01-01

    Computer-based clinical decision support (CDS) systems have been shown to improve quality of care and workflow efficiency, and health care reform legislation relies on electronic health records and CDS systems to improve the cost and quality of health care in the United States; however, the heterogeneity of CDS content and infrastructure of CDS systems across sites is not well known. We aimed to determine the scope of CDS content in diabetes care at six sites, assess the capabilities of CDS in use at these sites, characterize the scope of CDS infrastructure at these sites, and determine how the sites use CDS beyond individual patient care in order to identify characteristics of CDS systems and content that have been successfully implemented in diabetes care. We compared CDS systems in six collaborating sites of the Clinical Decision Support Consortium. We gathered CDS content on care for patients with diabetes mellitus and surveyed institutions on characteristics of their site, the infrastructure of CDS at these sites, and the capabilities of CDS at these sites. The approach to CDS and the characteristics of CDS content varied among sites. Some commonalities included providing customizability by role or user, applying sophisticated exclusion criteria, and using CDS automatically at the time of decision-making. Many messages were actionable recommendations. Most sites had monitoring rules (e.g. assessing hemoglobin A1c), but few had rules to diagnose diabetes or suggest specific treatments. All sites had numerous prevention rules including reminders for providing eye examinations, influenza vaccines, lipid screenings, nephropathy screenings, and pneumococcal vaccines. Computer-based CDS systems vary widely across sites in content and scope, but both institution-created and purchased systems had many similar features and functionality, such as integration of alerts and reminders into the decision-making workflow of the provider and providing messages that are actionable recommendations.

  7. Clinical decision support improves quality of telephone triage documentation - an analysis of triage documentation before and after computerized clinical decision support

    PubMed Central

    2014-01-01

    Background Clinical decision support (CDS) has been shown to be effective in improving medical safety and quality but there is little information on how telephone triage benefits from CDS. The aim of our study was to compare triage documentation quality associated with the use of a clinical decision support tool, ExpertRN©. Methods We examined 50 triage documents before and after a CDS tool was used in nursing triage. To control for the effects of CDS training we had an additional control group of triage documents created by nurses who were trained in the CDS tool, but who did not use it in selected notes. The CDS intervention cohort of triage notes was compared to both the pre-CDS notes and the CDS trained (but not using CDS) cohort. Cohorts were compared using the documentation standards of the American Academy of Ambulatory Care Nursing (AAACN). We also compared triage note content (documentation of associated positive and negative features relating to the symptoms, self-care instructions, and warning signs to watch for), and documentation defects pertinent to triage safety. Results Three of five AAACN documentation standards were significantly improved with CDS. There was a mean of 36.7 symptom features documented in triage notes for the CDS group but only 10.7 symptom features in the pre-CDS cohort (p < 0.0001) and 10.2 for the cohort that was CDS-trained but not using CDS (p < 0.0001). The difference between the mean of 10.2 symptom features documented in the pre-CDS and the mean of 10.7 symptom features documented in the CDS-trained but not using was not statistically significant (p = 0.68). Conclusions CDS significantly improves triage note documentation quality. CDS-aided triage notes had significantly more information about symptoms, warning signs and self-care. The changes in triage documentation appeared to be the result of the CDS alone and not due to any CDS training that came with the CDS intervention. Although this study shows that CDS can improve documentation, further study is needed to determine if it results in improved care. PMID:24645674

  8. Clinical decision support improves quality of telephone triage documentation--an analysis of triage documentation before and after computerized clinical decision support.

    PubMed

    North, Frederick; Richards, Debra D; Bremseth, Kimberly A; Lee, Mary R; Cox, Debra L; Varkey, Prathibha; Stroebel, Robert J

    2014-03-20

    Clinical decision support (CDS) has been shown to be effective in improving medical safety and quality but there is little information on how telephone triage benefits from CDS. The aim of our study was to compare triage documentation quality associated with the use of a clinical decision support tool, ExpertRN©. We examined 50 triage documents before and after a CDS tool was used in nursing triage. To control for the effects of CDS training we had an additional control group of triage documents created by nurses who were trained in the CDS tool, but who did not use it in selected notes. The CDS intervention cohort of triage notes was compared to both the pre-CDS notes and the CDS trained (but not using CDS) cohort. Cohorts were compared using the documentation standards of the American Academy of Ambulatory Care Nursing (AAACN). We also compared triage note content (documentation of associated positive and negative features relating to the symptoms, self-care instructions, and warning signs to watch for), and documentation defects pertinent to triage safety. Three of five AAACN documentation standards were significantly improved with CDS. There was a mean of 36.7 symptom features documented in triage notes for the CDS group but only 10.7 symptom features in the pre-CDS cohort (p < 0.0001) and 10.2 for the cohort that was CDS-trained but not using CDS (p < 0.0001). The difference between the mean of 10.2 symptom features documented in the pre-CDS and the mean of 10.7 symptom features documented in the CDS-trained but not using was not statistically significant (p = 0.68). CDS significantly improves triage note documentation quality. CDS-aided triage notes had significantly more information about symptoms, warning signs and self-care. The changes in triage documentation appeared to be the result of the CDS alone and not due to any CDS training that came with the CDS intervention. Although this study shows that CDS can improve documentation, further study is needed to determine if it results in improved care.

  9. Design and Development of a Sharable Clinical Decision Support System Based on a Semantic Web Service Framework.

    PubMed

    Zhang, Yi-Fan; Gou, Ling; Tian, Yu; Li, Tian-Chang; Zhang, Mao; Li, Jing-Song

    2016-05-01

    Clinical decision support (CDS) systems provide clinicians and other health care stakeholders with patient-specific assessments or recommendations to aid in the clinical decision-making process. Despite their demonstrated potential for improving health care quality, the widespread availability of CDS systems has been limited mainly by the difficulty and cost of sharing CDS knowledge among heterogeneous healthcare information systems. The purpose of this study was to design and develop a sharable clinical decision support (S-CDS) system that meets this challenge. The fundamental knowledge base consists of independent and reusable knowledge modules (KMs) to meet core CDS needs, wherein each KM is semantically well defined based on the standard information model, terminologies, and representation formalisms. A semantic web service framework was developed to identify, access, and leverage these KMs across diverse CDS applications and care settings. The S-CDS system has been validated in two distinct client CDS applications. Model-level evaluation results confirmed coherent knowledge representation. Application-level evaluation results reached an overall accuracy of 98.66 % and a completeness of 96.98 %. The evaluation results demonstrated the technical feasibility and application prospect of our approach. Compared with other CDS engineering efforts, our approach facilitates system development and implementation and improves system maintainability, scalability and efficiency, which contribute to the widespread adoption of effective CDS within the healthcare domain.

  10. Developing an Interactive Data Visualization Tool to Assess the Impact of Decision Support on Clinical Operations.

    PubMed

    Huber, Timothy C; Krishnaraj, Arun; Monaghan, Dayna; Gaskin, Cree M

    2018-05-18

    Due to mandates from recent legislation, clinical decision support (CDS) software is being adopted by radiology practices across the country. This software provides imaging study decision support for referring providers at the point of order entry. CDS systems produce a large volume of data, providing opportunities for research and quality improvement. In order to better visualize and analyze trends in this data, an interactive data visualization dashboard was created using a commercially available data visualization platform. Following the integration of a commercially available clinical decision support product into the electronic health record, a dashboard was created using a commercially available data visualization platform (Tableau, Seattle, WA). Data generated by the CDS were exported from the data warehouse, where they were stored, into the platform. This allowed for real-time visualization of the data generated by the decision support software. The creation of the dashboard allowed the output from the CDS platform to be more easily analyzed and facilitated hypothesis generation. Integrating data visualization tools into clinical decision support tools allows for easier data analysis and can streamline research and quality improvement efforts.

  11. Towards meaningful medication-related clinical decision support: recommendations for an initial implementation.

    PubMed

    Phansalkar, S; Wright, A; Kuperman, G J; Vaida, A J; Bobb, A M; Jenders, R A; Payne, T H; Halamka, J; Bloomrosen, M; Bates, D W

    2011-01-01

    Clinical decision support (CDS) can improve safety, quality, and cost-effectiveness of patient care, especially when implemented in computerized provider order entry (CPOE) applications. Medication-related decision support logic forms a large component of the CDS logic in any CPOE system. However, organizations wishing to implement CDS must either purchase the computable clinical content or develop it themselves. Content provided by vendors does not always meet local expectations. Most organizations lack the resources to customize the clinical content and the expertise to implement it effectively. In this paper, we describe the recommendations of a national expert panel on two basic medication-related CDS areas, specifically, drug-drug interaction (DDI) checking and duplicate therapy checking. The goals of this study were to define a starter set of medication-related alerts that healthcare organizations can implement in their clinical information systems. We also draw on the experiences of diverse institutions to highlight the realities of implementing medication decision support. These findings represent the experiences of institutions with a long history in the domain of medication decision support, and the hope is that this guidance may improve the feasibility and efficiency CDS adoption across healthcare settings.

  12. Development of a Tailored Intervention With Computerized Clinical Decision Support to Improve Quality of Care for Patients With Knee Osteoarthritis: Multi-Method Study.

    PubMed

    Van de Velde, Stijn; Kortteisto, Tiina; Spitaels, David; Jamtvedt, Gro; Roshanov, Pavel; Kunnamo, Ilkka; Aertgeerts, Bert; Vandvik, Per Olav; Flottorp, Signe

    2018-06-11

    Clinical practice patterns greatly diverge from evidence-based recommendations to manage knee osteoarthritis conservatively before resorting to surgery. This study aimed to tailor a guideline-based computerized decision support (CDS) intervention that facilitates the conservative management of knee osteoarthritis. Experts with backgrounds in clinical medicine, research, implementation, or health informatics suggested the most important recommendations for implementation, how to develop an implementation strategy, and how to form the CDS algorithms. In 6 focus group sessions, 8 general practitioners and 22 patients from Norway, Belgium, and Finland discussed the suggested CDS intervention and identified factors that would be most critical for the success of the intervention. The focus group moderators used the GUideline Implementation with DEcision Support checklist, which we developed to support consideration of CDS success factors. The experts prioritized 9 out of 22 recommendations for implementation. We formed the concept for 6 CDS algorithms to support implementation of these recommendations. The focus group suggested 59 unique factors that could affect the success of the presented CDS intervention. Five factors (out of the 59) were prioritized by focus group participants in every country, including the perceived potential to address the information needs of both patients and general practitioners; the credibility of CDS information; the timing of CDS for patients; and the need for personal dialogue about CDS between the general practitioner and the patient. The focus group participants supported the CDS intervention as a tool to improve the quality of care for patients with knee osteoarthritis through shared, evidence-based decision making. We aim to develop and implement the CDS based on these study results. Future research should address optimal ways to (1) provide patient-directed CDS, (2) enable more patient-specific CDS within the context of patient complexity, and (3) maintain user engagement with CDS over time. ©Stijn Van de Velde, Tiina Kortteisto, David Spitaels, Gro Jamtvedt, Pavel Roshanov, Ilkka Kunnamo, Bert Aertgeerts, Per Olav Vandvik, Signe Flottorp. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 11.06.2018.

  13. Medication-related clinical decision support in computerized provider order entry systems: a review.

    PubMed

    Kuperman, Gilad J; Bobb, Anne; Payne, Thomas H; Avery, Anthony J; Gandhi, Tejal K; Burns, Gerard; Classen, David C; Bates, David W

    2007-01-01

    While medications can improve patients' health, the process of prescribing them is complex and error prone, and medication errors cause many preventable injuries. Computer provider order entry (CPOE) with clinical decision support (CDS), can improve patient safety and lower medication-related costs. To realize the medication-related benefits of CDS within CPOE, one must overcome significant challenges. Healthcare organizations implementing CPOE must understand what classes of CDS their CPOE systems can support, assure that clinical knowledge underlying their CDS systems is reasonable, and appropriately represent electronic patient data. These issues often influence to what extent an institution will succeed with its CPOE implementation and achieve its desired goals. Medication-related decision support is probably best introduced into healthcare organizations in two stages, basic and advanced. Basic decision support includes drug-allergy checking, basic dosing guidance, formulary decision support, duplicate therapy checking, and drug-drug interaction checking. Advanced decision support includes dosing support for renal insufficiency and geriatric patients, guidance for medication-related laboratory testing, drug-pregnancy checking, and drug-disease contraindication checking. In this paper, the authors outline some of the challenges associated with both basic and advanced decision support and discuss how those challenges might be addressed. The authors conclude with summary recommendations for delivering effective medication-related clinical decision support addressed to healthcare organizations, application and knowledge base vendors, policy makers, and researchers.

  14. Grand Challenges in Clinical Decision Support v10

    PubMed Central

    Sittig, Dean F.; Wright, Adam; Osheroff, Jerome A.; Middleton, Blackford; Teich, Jonathan M.; Ash, Joan S.; Campbell, Emily; Bates, David W.

    2008-01-01

    There is a pressing need for high-quality, effective means of designing, developing, presenting, implementing, evaluating, and maintaining all types of clinical decision support capabilities for clinicians, patients and consumers. Using an iterative, consensus-building process we identified a rank-ordered list of the top 10 grand challenges in clinical decision support. This list was created to educate and inspire researchers, developers, funders, and policy-makers. The list of challenges in order of importance that they be solved if patients and organizations are to begin realizing the fullest benefits possible of these systems consists of: Improve the human-computer interface; Disseminate best practices in CDS design, development, and implementation; Summarize patient-level information; Prioritize and filter recommendations to the user; Create an architecture for sharing executable CDS modules and services; Combine recommendations for patients with co-morbidities; Prioritize CDS content development and implementation; Create internet-accessible clinical decision support repositories; Use freetext information to drive clinical decision support; Mine large clinical databases to create new CDS. Identification of solutions to these challenges is critical if clinical decision support is to achieve its potential and improve the quality, safety and efficiency of healthcare. PMID:18029232

  15. Design Recommendations for Pharmacogenomics Clinical Decision Support Systems

    PubMed Central

    Khelifi, Maher; Tarczy-Hornoch, Peter; Devine, Emily B.; Pratt, Wanda

    2017-01-01

    The use of pharmacogenomics (PGx) in clinical practice still faces challenges to fully adopt genetic information in targeting drug therapy. To incorporate genetics into clinical practice, many support the use of Pharmacogenomics Clinical Decision Support Systems (PGx-CDS) for medication prescriptions. This support was fueled by new guidelines to incorporate genetics for optimizing drug dosage and reducing adverse events. In addition, the complexity of PGx led to exploring CDS outside the paradigm of the basic CDS tools embedded in commercial electronic health records. Therefore, designing the right CDS is key to unleashing the full potential of pharmacogenomics and making it a part of clinicians’ daily workflow. In this work, we 1) identify challenges and barriers of the implementation of PGx-CDS in clinical settings, 2) develop a new design approach to CDS with functional characteristics that can improve the adoption of pharmacogenomics guidelines and thus patient safety, and 3) create design guidelines and recommendations for such PGx-CDS tools. PMID:28815136

  16. What can Natural Language Processing do for Clinical Decision Support?

    PubMed Central

    Demner-Fushman, Dina; Chapman, Wendy W.; McDonald, Clement J.

    2009-01-01

    Computerized Clinical Decision Support (CDS) aims to aid decision making of health care providers and the public by providing easily accessible health-related information at the point and time it is needed. Natural Language Processing (NLP) is instrumental in using free-text information to drive CDS, representing clinical knowledge and CDS interventions in standardized formats, and leveraging clinical narrative. The early innovative NLP research of clinical narrative was followed by a period of stable research conducted at the major clinical centers and a shift of mainstream interest to biomedical NLP. This review primarily focuses on the recently renewed interest in development of fundamental NLP methods and advances in the NLP systems for CDS. The current solutions to challenges posed by distinct sublanguages, intended user groups, and support goals are discussed. PMID:19683066

  17. Use of Mobile Clinical Decision Support Software by Junior Doctors at a UK Teaching Hospital: Identification and Evaluation of Barriers to Engagement.

    PubMed

    Patel, Rakesh; Green, William; Shahzad, Muhammad Waseem; Larkin, Chris

    2015-08-13

    Clinical decision support (CDS) tools improve clinical diagnostic decision making and patient safety. The availability of CDS to health care professionals has grown in line with the increased prevalence of apps and smart mobile devices. Despite these benefits, patients may have safety concerns about the use of mobile devices around medical equipment. This research explored the engagement of junior doctors (JDs) with CDS and the perceptions of patients about their use. There were three objectives for this research: (1) to measure the actual usage of CDS tools on mobile devices (mCDS) by JDs, (2) to explore the perceptions of JDs about the drivers and barriers to using mCDS, and (3) to explore the perceptions of patients about the use of mCDS. This study used a mixed-methods approach to study the engagement of JDs with CDS accessed through mobile devices. Usage data were collected on the number of interactions by JDs with mCDS. The perceived drivers and barriers for JDs to using CDS were then explored by interviews. Finally, these findings were contrasted with the perception of patients about the use of mCDS by JDs. Nine of the 16 JDs made a total of 142 recorded interactions with the mCDS over a 4-month period. Only 27 of the 114 interactions (24%) that could be categorized as on-shift or off-shift occurred on-shift. Eight individual, institutional, and cultural barriers to engagement emerged from interviews with the user group. In contrast to reported cautions and concerns about the impact of clinicians' use of mobile phone on patient health and safety, patients had positive perceptions about the use of mCDS. Patients reported positive perceptions toward mCDS. The usage of mCDS to support clinical decision making was considered to be positive as part of everyday clinical practice. The degree of engagement was found to be limited due to a number of individual, institutional, and cultural barriers. The majority of mCDS engagement occurred outside of the workplace. Further research is required to verify these findings and assess their implications for future policy and practice.

  18. Creating Shareable Clinical Decision Support Rules for a Pharmacogenomics Clinical Guideline Using Structured Knowledge Representation.

    PubMed

    Linan, Margaret K; Sottara, Davide; Freimuth, Robert R

    2015-01-01

    Pharmacogenomics (PGx) guidelines contain drug-gene relationships, therapeutic and clinical recommendations from which clinical decision support (CDS) rules can be extracted, rendered and then delivered through clinical decision support systems (CDSS) to provide clinicians with just-in-time information at the point of care. Several tools exist that can be used to generate CDS rules that are based on computer interpretable guidelines (CIG), but none have been previously applied to the PGx domain. We utilized the Unified Modeling Language (UML), the Health Level 7 virtual medical record (HL7 vMR) model, and standard terminologies to represent the semantics and decision logic derived from a PGx guideline, which were then mapped to the Health eDecisions (HeD) schema. The modeling and extraction processes developed here demonstrate how structured knowledge representations can be used to support the creation of shareable CDS rules from PGx guidelines.

  19. Clinical decision support for whole genome sequence information leveraging a service-oriented architecture: a prototype.

    PubMed

    Welch, Brandon M; Rodriguez-Loya, Salvador; Eilbeck, Karen; Kawamoto, Kensaku

    2014-01-01

    Whole genome sequence (WGS) information could soon be routinely available to clinicians to support the personalized care of their patients. At such time, clinical decision support (CDS) integrated into the clinical workflow will likely be necessary to support genome-guided clinical care. Nevertheless, developing CDS capabilities for WGS information presents many unique challenges that need to be overcome for such approaches to be effective. In this manuscript, we describe the development of a prototype CDS system that is capable of providing genome-guided CDS at the point of care and within the clinical workflow. To demonstrate the functionality of this prototype, we implemented a clinical scenario of a hypothetical patient at high risk for Lynch Syndrome based on his genomic information. We demonstrate that this system can effectively use service-oriented architecture principles and standards-based components to deliver point of care CDS for WGS information in real-time.

  20. Implementation Pearls from a New Guidebook on Improving Medication Use and Outcomes with Clinical Decision Support

    PubMed Central

    Sirajuddin, Anwar M; Osheroff, Jerome A.; Sittig, Dean F.; Chuo, John; Velasco, Ferdinand; Collins, David A.

    2012-01-01

    Effective clinical decision support (CDS) is essential for addressing healthcare performance improvement imperatives, but care delivery organizations (CDO) typically struggle with CDS deployment. Ensuring safe and effective medication delivery to patients is a central focus of CDO performance improvement efforts, and this article provides an overview of best-practice strategies for applying CDS to these goals. The strategies discussed are drawn from a new guidebook, co-published and co-sponsored by more than a dozen leading organizations. Developed by scores of CDS implementers and experts, the guidebook outlines key steps and success factors for applying CDS to medication management. A central thesis is that improving outcomes with CDS interventions requires that the CDS five rights be addressed successfully. That is, the interventions must deliver the right information, to the right person, in the right format, through the right channel, at the right point in workflow. This paper provides further details about these CDS five rights, and highlights other important strategies for successful CDS programs. PMID:19894486

  1. A pilot study of distributed knowledge management and clinical decision support in the cloud.

    PubMed

    Dixon, Brian E; Simonaitis, Linas; Goldberg, Howard S; Paterno, Marilyn D; Schaeffer, Molly; Hongsermeier, Tonya; Wright, Adam; Middleton, Blackford

    2013-09-01

    Implement and perform pilot testing of web-based clinical decision support services using a novel framework for creating and managing clinical knowledge in a distributed fashion using the cloud. The pilot sought to (1) develop and test connectivity to an external clinical decision support (CDS) service, (2) assess the exchange of data to and knowledge from the external CDS service, and (3) capture lessons to guide expansion to more practice sites and users. The Clinical Decision Support Consortium created a repository of shared CDS knowledge for managing hypertension, diabetes, and coronary artery disease in a community cloud hosted by Partners HealthCare. A limited data set for primary care patients at a separate health system was securely transmitted to a CDS rules engine hosted in the cloud. Preventive care reminders triggered by the limited data set were returned for display to clinician end users for review and display. During a pilot study, we (1) monitored connectivity and system performance, (2) studied the exchange of data and decision support reminders between the two health systems, and (3) captured lessons. During the six month pilot study, there were 1339 patient encounters in which information was successfully exchanged. Preventive care reminders were displayed during 57% of patient visits, most often reminding physicians to monitor blood pressure for hypertensive patients (29%) and order eye exams for patients with diabetes (28%). Lessons learned were grouped into five themes: performance, governance, semantic interoperability, ongoing adjustments, and usability. Remote, asynchronous cloud-based decision support performed reasonably well, although issues concerning governance, semantic interoperability, and usability remain key challenges for successful adoption and use of cloud-based CDS that will require collaboration between biomedical informatics and computer science disciplines. Decision support in the cloud is feasible and may be a reasonable path toward achieving better support of clinical decision-making across the widest range of health care providers. Published by Elsevier B.V.

  2. Automating Guidelines for Clinical Decision Support: Knowledge Engineering and Implementation.

    PubMed

    Tso, Geoffrey J; Tu, Samson W; Oshiro, Connie; Martins, Susana; Ashcraft, Michael; Yuen, Kaeli W; Wang, Dan; Robinson, Amy; Heidenreich, Paul A; Goldstein, Mary K

    2016-01-01

    As utilization of clinical decision support (CDS) increases, it is important to continue the development and refinement of methods to accurately translate the intention of clinical practice guidelines (CPG) into a computable form. In this study, we validate and extend the 13 steps that Shiffman et al. 5 identified for translating CPG knowledge for use in CDS. During an implementation project of ATHENA-CDS, we encoded complex CPG recommendations for five common chronic conditions for integration into an existing clinical dashboard. Major decisions made during the implementation process were recorded and categorized according to the 13 steps. During the implementation period, we categorized 119 decisions and identified 8 new categories required to complete the project. We provide details on an updated model that outlines all of the steps used to translate CPG knowledge into a CDS integrated with existing health information technology.

  3. Structured representation for core elements of common clinical decision support interventions to facilitate knowledge sharing.

    PubMed

    Zhou, Li; Hongsermeier, Tonya; Boxwala, Aziz; Lewis, Janet; Kawamoto, Kensaku; Maviglia, Saverio; Gentile, Douglas; Teich, Jonathan M; Rocha, Roberto; Bell, Douglas; Middleton, Blackford

    2013-01-01

    At present, there are no widely accepted, standard approaches for representing computer-based clinical decision support (CDS) intervention types and their structural components. This study aimed to identify key requirements for the representation of five widely utilized CDS intervention types: alerts and reminders, order sets, infobuttons, documentation templates/forms, and relevant data presentation. An XML schema was proposed for representing these interventions and their core structural elements (e.g., general metadata, applicable clinical scenarios, CDS inputs, CDS outputs, and CDS logic) in a shareable manner. The schema was validated by building CDS artifacts for 22 different interventions, targeted toward guidelines and clinical conditions called for in the 2011 Meaningful Use criteria. Custom style sheets were developed to render the XML files in human-readable form. The CDS knowledge artifacts were shared via a public web portal. Our experience also identifies gaps in existing standards and informs future development of standards for CDS knowledge representation and sharing.

  4. Clinical decision support for genetically guided personalized medicine: a systematic review

    PubMed Central

    Welch, Brandon M

    2013-01-01

    Objective To review the literature on clinical decision support (CDS) for genetically guided personalized medicine (GPM). Materials and Methods MEDLINE and Embase were searched from 1990 to 2011. The manuscripts included were summarized, and notable themes and trends were identified. Results Following a screening of 3416 articles, 38 primary research articles were identified. Focal areas of research included family history-driven CDS, cancer management, and pharmacogenomics. Nine randomized controlled trials of CDS interventions for GPM were identified, seven of which reported positive results. The majority of manuscripts were published on or after 2007, with increased recent focus on genotype-driven CDS and the integration of CDS within primary clinical information systems. Discussion Substantial research has been conducted to date on the use of CDS to enable GPM. In a previous analysis of CDS intervention trials, the automatic provision of CDS as a part of routine clinical workflow had been identified as being critical for CDS effectiveness. There was some indication that CDS for GPM could potentially be effective without the CDS being provided automatically, but we did not find conclusive evidence to support this hypothesis. Conclusion To maximize the clinical benefits arising from ongoing discoveries in genetics and genomics, additional research and development is recommended for identifying how best to leverage CDS to bridge the gap between the promise and realization of GPM. PMID:22922173

  5. Analysis of Nursing Clinical Decision Support Requests and Strategic Plan in a Large Academic Health System.

    PubMed

    Whalen, Kimberly; Bavuso, Karen; Bouyer-Ferullo, Sharon; Goldsmith, Denise; Fairbanks, Amanda; Gesner, Emily; Lagor, Charles; Collins, Sarah

    2016-01-01

    To understand requests for nursing Clinical Decision Support (CDS) interventions at a large integrated health system undergoing vendor-based EHR implementation. In addition, to establish a process to guide both short-term implementation and long-term strategic goals to meet nursing CDS needs. We conducted an environmental scan to understand current state of nursing CDS over three months. The environmental scan consisted of a literature review and an analysis of CDS requests received from across our health system. We identified existing high priority CDS and paper-based tools used in nursing practice at our health system that guide decision-making. A total of 46 nursing CDS requests were received. Fifty-six percent (n=26) were specific to a clinical specialty; 22 percent (n=10) were focused on facilitating clinical consults in the inpatient setting. "Risk Assessments/Risk Reduction/Promotion of Healthy Habits" (n=23) was the most requested High Priority Category received for nursing CDS. A continuum of types of nursing CDS needs emerged using the Data-Information-Knowledge-Wisdom Conceptual Framework: 1) facilitating data capture, 2) meeting information needs, 3) guiding knowledge-based decision making, and 4) exposing analytics for wisdom-based clinical interpretation by the nurse. Identifying and prioritizing paper-based tools that can be modified into electronic CDS is a challenge. CDS strategy is an evolving process that relies on close collaboration and engagement with clinical sites for short-term implementation and should be incorporated into a long-term strategic plan that can be optimized and achieved overtime. The Data-Information-Knowledge-Wisdom Conceptual Framework in conjunction with the High Priority Categories established may be a useful tool to guide a strategic approach for meeting short-term nursing CDS needs and aligning with the organizational strategic plan.

  6. Recommendations for Clinical Decision Support Deployment: Synthesis of a Roundtable of Medical Directors of Information Systems

    PubMed Central

    Jenders, Robert A.; Osheroff, Jerome A.; Sittig, Dean F.; Pifer, Eric A.; Teich, Jonathan M

    2007-01-01

    Background: Ample evidence exists that clinical decision support (CDS) can improve clinician performance. Nevertheless, additional evidence demonstrates that clinicians still do not perform adequately in many instances. This suggests an ongoing need for implementation of CDS, in turn prompting development of a roadmap for national action regarding CDS. Objective: Develop practical advice to aid CDS implementation in order to improve clinician performance. Method: Structured group interview during a roundtable discussion by medical directors of information systems (N = 30), with subsequent review by participants and synthesis. Results: Participant consensus was that CDS should be comprehensive and should involve techniques such as order sets and facilitated documentation as well as alerts; should be subject to ongoing feedback; and should flow from and be governed by an organization’s clinical goals. Conclusion: A structured roundtable discussion of clinicians experienced in health information technology can yield practical, consensus advice for implementation of CDS. PMID:18693858

  7. Behavioral medicine perspectives on the design of health information technology to improve decision-making, guideline adherence, and care coordination in chronic pain management.

    PubMed

    Midboe, Amanda M; Lewis, Eleanor T; Cronkite, Ruth C; Chambers, Dallas; Goldstein, Mary K; Kerns, Robert D; Trafton, Jodie A

    2011-03-01

    Development of clinical decision support systems (CDSs) has tended to focus on facilitating medication management. An understanding of behavioral medicine perspectives on the usefulness of a CDS for patient care can expand CDSs to improve management of chronic disease. The purpose of this study is to explore feedback from behavioral medicine providers regarding the potential for CDSs to improve decision-making, care coordination, and guideline adherence in pain management. Qualitative methods were used to analyze semi-structured interview responses from behavioral medicine stakeholders following demonstration of an existing CDS for opioid prescribing, ATHENA-OT. Participants suggested that a CDS could assist with decision-making by educating providers, providing recommendations about behavioral therapy, facilitating risk assessment, and improving referral decisions. They suggested that a CDS could improve care coordination by facilitating division of workload, improving patient education, and increasing consideration and knowledge of options in other disciplines. Clinical decision support systems are promising tools for improving behavioral medicine care for chronic pain.

  8. Reducing risk with clinical decision support: a study of closed malpractice claims.

    PubMed

    Zuccotti, G; Maloney, F L; Feblowitz, J; Samal, L; Sato, L; Wright, A

    2014-01-01

    Identify clinical opportunities to intervene to prevent a malpractice event and determine the proportion of malpractice claims potentially preventable by clinical decision support (CDS). Cross-sectional review of closed malpractice claims over seven years from one malpractice insurance company and seven hospitals in the Boston area. For each event, clinical opportunities to intervene to avert the malpractice event and the presence or absence of CDS that might have a role in preventing the event, were assigned by a panel of expert raters. Compensation paid out to resolve a claim (indemnity), was associated with each CDS type. Of the 477 closed malpractice cases, 359 (75.3%) were categorized as substantiated and 195 (54%) had at least one opportunity to intervene. Common opportunities to intervene related to performance of procedure, diagnosis, and fall prevention. We identified at least one CDS type for 63% of substantiated claims. The 41 CDS types identified included clinically significant test result alerting, diagnostic decision support and electronic tracking of instruments. Cases with at least one associated intervention accounted for $40.3 million (58.9%) of indemnity. CDS systems and other forms of health information technology (HIT) are expected to improve quality of care, but their potential to mitigate risk had not previously been quantified. Our results suggest that, in addition to their known benefits for quality and safety, CDS systems within HIT have a potential role in decreasing malpractice payments. More than half of malpractice events and over $40 million of indemnity were potentially preventable with CDS.

  9. A qualitative study of the activities performed by people involved in clinical decision support: recommended practices for success.

    PubMed

    Wright, Adam; Ash, Joan S; Erickson, Jessica L; Wasserman, Joe; Bunce, Arwen; Stanescu, Ana; St Hilaire, Daniel; Panzenhagen, Morgan; Gebhardt, Eric; McMullen, Carmit; Middleton, Blackford; Sittig, Dean F

    2014-01-01

    To describe the activities performed by people involved in clinical decision support (CDS) at leading sites. We conducted ethnographic observations at seven diverse sites with a history of excellence in CDS using the Rapid Assessment Process and analyzed the data using a series of card sorts, informed by Linstone's Multiple Perspectives Model. We identified 18 activities and grouped them into four areas. Area 1: Fostering relationships across the organization, with activities (a) training and support, (b) visibility/presence on the floor, (c) liaising between people, (d) administration and leadership, (e) project management, (f) cheerleading/buy-in/sponsorship, (g) preparing for CDS implementation. Area 2: Assembling the system with activities (a) providing technical support, (b) CDS content development, (c) purchasing products from vendors (d) knowledge management, (e) system integration. Area 3: Using CDS to achieve the organization's goals with activities (a) reporting, (b) requirements-gathering/specifications, (c) monitoring CDS, (d) linking CDS to goals, (e) managing data. Area 4: Participation in external policy and standards activities (this area consists of only a single activity). We also identified a set of recommendations associated with these 18 activities. All 18 activities we identified were performed at all sites, although the way they were organized into roles differed substantially. We consider these activities critical to the success of a CDS program. A series of activities are performed by sites strong in CDS, and sites adopting CDS should ensure they incorporate these activities into their efforts.

  10. Evaluation of the Effect of Decision Support on the Efficiency of Primary Care Providers in the Outpatient Practice

    PubMed Central

    Hankey, Ronald A.; Decker, Lindsay K.; Cha, Stephen S.; Greenes, Robert A.; Liu, Hongfang; Chaudhry, Rajeev

    2015-01-01

    Background: Clinical decision support (CDS) for primary care has been shown to improve delivery of preventive services. However, there is little evidence for efficiency of physicians due to CDS assistance. In this article, we report a pilot study for measuring the impact of CDS on the time spent by physicians for deciding on preventive services and chronic disease management. Methods: We randomly selected 30 patients from a primary care practice, and assigned them to 10 physicians. The physicians were requested to perform chart review to decide on preventive services and chronic disease management for the assigned patients. The patients assignment was done in a randomized crossover design, such that each patient received 2 sets of recommendations—one from a physician with CDS assistance and the other from a different physician without CDS assistance. We compared the physician recommendations made using CDS assistance, with the recommendations made without CDS assistance. Results: The physicians required an average of 1 minute 44 seconds, when they were they had access to the decision support system and 5 minutes when they were unassisted. Hence the CDS assistance resulted in an estimated saving of 3 minutes 16 seconds (65%) of the physicians’ time, which was statistically significant (P < .0001). There was no statistically significant difference in the number of recommendations. Conclusion: Our findings suggest that CDS assistance significantly reduced the time spent by physicians for deciding on preventive services and chronic disease management. The result needs to be confirmed by performing similar studies at other institutions. PMID:25155103

  11. The GUIDES checklist: development of a tool to improve the successful use of guideline-based computerised clinical decision support.

    PubMed

    Van de Velde, Stijn; Kunnamo, Ilkka; Roshanov, Pavel; Kortteisto, Tiina; Aertgeerts, Bert; Vandvik, Per Olav; Flottorp, Signe

    2018-06-25

    Computerised decision support (CDS) based on trustworthy clinical guidelines is a key component of a learning healthcare system. Research shows that the effectiveness of CDS is mixed. Multifaceted context, system, recommendation and implementation factors may potentially affect the success of CDS interventions. This paper describes the development of a checklist that is intended to support professionals to implement CDS successfully. We developed the checklist through an iterative process that involved a systematic review of evidence and frameworks, a synthesis of the success factors identified in the review, feedback from an international expert panel that evaluated the checklist in relation to a list of desirable framework attributes, consultations with patients and healthcare consumers and pilot testing of the checklist. We screened 5347 papers and selected 71 papers with relevant information on success factors for guideline-based CDS. From the selected papers, we developed a 16-factor checklist that is divided in four domains, i.e. the CDS context, content, system and implementation domains. The panel of experts evaluated the checklist positively as an instrument that could support people implementing guideline-based CDS across a wide range of settings globally. Patients and healthcare consumers identified guideline-based CDS as an important quality improvement intervention and perceived the GUIDES checklist as a suitable and useful strategy. The GUIDES checklist can support professionals in considering the factors that affect the success of CDS interventions. It may facilitate a deeper and more accurate understanding of the factors shaping CDS effectiveness. Relying on a structured approach may prevent that important factors are missed.

  12. Lung Cancer Assistant: a hybrid clinical decision support application for lung cancer care.

    PubMed

    Sesen, M Berkan; Peake, Michael D; Banares-Alcantara, Rene; Tse, Donald; Kadir, Timor; Stanley, Roz; Gleeson, Fergus; Brady, Michael

    2014-09-06

    Multidisciplinary team (MDT) meetings are becoming the model of care for cancer patients worldwide. While MDTs have improved the quality of cancer care, the meetings impose substantial time pressure on the members, who generally attend several such MDTs. We describe Lung Cancer Assistant (LCA), a clinical decision support (CDS) prototype designed to assist the experts in the treatment selection decisions in the lung cancer MDTs. A novel feature of LCA is its ability to provide rule-based and probabilistic decision support within a single platform. The guideline-based CDS is based on clinical guideline rules, while the probabilistic CDS is based on a Bayesian network trained on the English Lung Cancer Audit Database (LUCADA). We assess rule-based and probabilistic recommendations based on their concordances with the treatments recorded in LUCADA. Our results reveal that the guideline rule-based recommendations perform well in simulating the recorded treatments with exact and partial concordance rates of 0.57 and 0.79, respectively. On the other hand, the exact and partial concordance rates achieved with probabilistic results are relatively poorer with 0.27 and 0.76. However, probabilistic decision support fulfils a complementary role in providing accurate survival estimations. Compared to recorded treatments, both CDS approaches promote higher resection rates and multimodality treatments.

  13. A Bridging Opportunities Work-frame to develop mobile applications for clinical decision making

    PubMed Central

    van Rooij, Tibor; Rix, Serena; Moore, James B; Marsh, Sharon

    2015-01-01

    Background: Mobile applications (apps) providing clinical decision support (CDS) may show the greatest promise when created by and for frontline clinicians. Our aim was to create a generic model enabling healthcare providers to direct the development of CDS apps. Methods: We combined Change Management with a three-tier information technology architecture to stimulate CDS app development. Results: A Bridging Opportunities Work-frame model was developed. A test case was used to successfully develop an app. Conclusion: Healthcare providers can re-use this globally applicable model to actively create and manage regional decision support applications to translate evidence-based medicine in the use of emerging medication or novel treatment regimens. PMID:28031883

  14. Scalable Clinical Decision Support for Individualized Cancer Risk Management | Informatics Technology for Cancer Research (ITCR)

    Cancer.gov

    We will build a scalable clinical decision support (CDS) platform that helps clinicians and patients select cancer screening strategies that are best suited to each individual. This kind of CDS is important because increased evidence supports personalizing cancer screening decisions according to each individual's unique cancer risks. While a highly desired goal, individualizing screening at a population scale requires the implementation of patient-specific risk assessments for several types of cancer. This is quite challenging in today's overwhelmed primary care environment.

  15. Standard practices for computerized clinical decision support in community hospitals: a national survey

    PubMed Central

    McCormack, James L; Sittig, Dean F; Wright, Adam; McMullen, Carmit; Bates, David W

    2012-01-01

    Objective Computerized provider order entry (CPOE) with clinical decision support (CDS) can help hospitals improve care. Little is known about what CDS is presently in use and how it is managed, however, especially in community hospitals. This study sought to address this knowledge gap by identifying standard practices related to CDS in US community hospitals with mature CPOE systems. Materials and Methods Representatives of 34 community hospitals, each of which had over 5 years experience with CPOE, were interviewed to identify standard practices related to CDS. Data were analyzed with a mix of descriptive statistics and qualitative approaches to the identification of patterns, themes and trends. Results This broad sample of community hospitals had robust levels of CDS despite their small size and the independent nature of many of their physician staff members. The hospitals uniformly used medication alerts and order sets, had sophisticated governance procedures for CDS, and employed staff to customize CDS. Discussion The level of customization needed for most CDS before implementation was greater than expected. Customization requires skilled individuals who represent an emerging manpower need at this type of hospital. Conclusion These results bode well for robust diffusion of CDS to similar hospitals in the process of adopting CDS and suggest that national policies to promote CDS use may be successful. PMID:22707744

  16. Clinical Decision Support in Electronic Prescribing: Recommendations and an Action Plan

    PubMed Central

    Teich, Jonathan M.; Osheroff, Jerome A.; Pifer, Eric A.; Sittig, Dean F.; Jenders, Robert A.

    2005-01-01

    Clinical decision support (CDS) in electronic prescribing (eRx) systems can improve the safety, quality, efficiency, and cost-effectiveness of care. However, at present, these potential benefits have not been fully realized. In this consensus white paper, we set forth recommendations and action plans in three critical domains: (1) advances in system capabilities, including basic and advanced sets of CDS interventions and knowledge, supporting database elements, operational features to improve usability and measure performance, and management and governance structures; (2) uniform standards, vocabularies, and centralized knowledge structures and services that could reduce rework by vendors and care providers, improve dissemination of well-constructed CDS interventions, promote generally applicable research in CDS methods, and accelerate the movement of new medical knowledge from research to practice; and (3) appropriate financial and legal incentives to promote adoption. PMID:15802474

  17. Enhancing Worker Health Through Clinical Decision Support (CDS): An Introduction to a Compilation.

    PubMed

    Filios, Margaret S; Storey, Eileen; Baron, Sherry; Luensman, Genevieve B; Shiffman, Richard N

    2017-11-01

    This article outlines an approach to developing clinical decision support (CDS) for conditions related to work and health. When incorporated in electronic health records, such CDS will assist primary care providers (PCPs) care for working patients. Three groups of Subject Matter Experts (SMEs) identified relevant clinical practice guidelines, best practices, and reviewed published literature concerning work-related asthma, return-to-work, and management of diabetes at work. SMEs developed one recommendation per topic that could be supported by electronic CDS. Reviews with PCPs, staff, and health information system implementers in five primary care settings confirmed that the approach was important and operationally sound. This compendium is intended to stimulate a dialogue between occupational health specialists and PCPs that will enhance the use of work information about patients in the primary care setting.

  18. Clinical Decision Support: a 25 Year Retrospective and a 25 Year Vision.

    PubMed

    Middleton, B; Sittig, D F; Wright, A

    2016-08-02

    The objective of this review is to summarize the state of the art of clinical decision support (CDS) circa 1990, review progress in the 25 year interval from that time, and provide a vision of what CDS might look like 25 years hence, or circa 2040. Informal review of the medical literature with iterative review and discussion among the authors to arrive at six axes (data, knowledge, inference, architecture and technology, implementation and integration, and users) to frame the review and discussion of selected barriers and facilitators to the effective use of CDS. In each of the six axes, significant progress has been made. Key advances in structuring and encoding standardized data with an increased availability of data, development of knowledge bases for CDS, and improvement of capabilities to share knowledge artifacts, explosion of methods analyzing and inferring from clinical data, evolution of information technologies and architectures to facilitate the broad application of CDS, improvement of methods to implement CDS and integrate CDS into the clinical workflow, and increasing sophistication of the end-user, all have played a role in improving the effective use of CDS in healthcare delivery. CDS has evolved dramatically over the past 25 years and will likely evolve just as dramatically or more so over the next 25 years. Increasingly, the clinical encounter between a clinician and a patient will be supported by a wide variety of cognitive aides to support diagnosis, treatment, care-coordination, surveillance and prevention, and health maintenance or wellness.

  19. A proposed clinical decision support architecture capable of supporting whole genome sequence information.

    PubMed

    Welch, Brandon M; Loya, Salvador Rodriguez; Eilbeck, Karen; Kawamoto, Kensaku

    2014-04-04

    Whole genome sequence (WGS) information may soon be widely available to help clinicians personalize the care and treatment of patients. However, considerable barriers exist, which may hinder the effective utilization of WGS information in a routine clinical care setting. Clinical decision support (CDS) offers a potential solution to overcome such barriers and to facilitate the effective use of WGS information in the clinic. However, genomic information is complex and will require significant considerations when developing CDS capabilities. As such, this manuscript lays out a conceptual framework for a CDS architecture designed to deliver WGS-guided CDS within the clinical workflow. To handle the complexity and breadth of WGS information, the proposed CDS framework leverages service-oriented capabilities and orchestrates the interaction of several independently-managed components. These independently-managed components include the genome variant knowledge base, the genome database, the CDS knowledge base, a CDS controller and the electronic health record (EHR). A key design feature is that genome data can be stored separately from the EHR. This paper describes in detail: (1) each component of the architecture; (2) the interaction of the components; and (3) how the architecture attempts to overcome the challenges associated with WGS information. We believe that service-oriented CDS capabilities will be essential to using WGS information for personalized medicine.

  20. A Proposed Clinical Decision Support Architecture Capable of Supporting Whole Genome Sequence Information

    PubMed Central

    Welch, Brandon M.; Rodriguez Loya, Salvador; Eilbeck, Karen; Kawamoto, Kensaku

    2014-01-01

    Whole genome sequence (WGS) information may soon be widely available to help clinicians personalize the care and treatment of patients. However, considerable barriers exist, which may hinder the effective utilization of WGS information in a routine clinical care setting. Clinical decision support (CDS) offers a potential solution to overcome such barriers and to facilitate the effective use of WGS information in the clinic. However, genomic information is complex and will require significant considerations when developing CDS capabilities. As such, this manuscript lays out a conceptual framework for a CDS architecture designed to deliver WGS-guided CDS within the clinical workflow. To handle the complexity and breadth of WGS information, the proposed CDS framework leverages service-oriented capabilities and orchestrates the interaction of several independently-managed components. These independently-managed components include the genome variant knowledge base, the genome database, the CDS knowledge base, a CDS controller and the electronic health record (EHR). A key design feature is that genome data can be stored separately from the EHR. This paper describes in detail: (1) each component of the architecture; (2) the interaction of the components; and (3) how the architecture attempts to overcome the challenges associated with WGS information. We believe that service-oriented CDS capabilities will be essential to using WGS information for personalized medicine. PMID:25411644

  1. A qualitative study of the activities performed by people involved in clinical decision support: recommended practices for success

    PubMed Central

    Wright, Adam; Ash, Joan S; Erickson, Jessica L; Wasserman, Joe; Bunce, Arwen; Stanescu, Ana; St Hilaire, Daniel; Panzenhagen, Morgan; Gebhardt, Eric; McMullen, Carmit; Middleton, Blackford; Sittig, Dean F

    2014-01-01

    Objective To describe the activities performed by people involved in clinical decision support (CDS) at leading sites. Materials and methods We conducted ethnographic observations at seven diverse sites with a history of excellence in CDS using the Rapid Assessment Process and analyzed the data using a series of card sorts, informed by Linstone's Multiple Perspectives Model. Results We identified 18 activities and grouped them into four areas. Area 1: Fostering relationships across the organization, with activities (a) training and support, (b) visibility/presence on the floor, (c) liaising between people, (d) administration and leadership, (e) project management, (f) cheerleading/buy-in/sponsorship, (g) preparing for CDS implementation. Area 2: Assembling the system with activities (a) providing technical support, (b) CDS content development, (c) purchasing products from vendors (d) knowledge management, (e) system integration. Area 3: Using CDS to achieve the organization's goals with activities (a) reporting, (b) requirements-gathering/specifications, (c) monitoring CDS, (d) linking CDS to goals, (e) managing data. Area 4: Participation in external policy and standards activities (this area consists of only a single activity). We also identified a set of recommendations associated with these 18 activities. Discussion All 18 activities we identified were performed at all sites, although the way they were organized into roles differed substantially. We consider these activities critical to the success of a CDS program. Conclusions A series of activities are performed by sites strong in CDS, and sites adopting CDS should ensure they incorporate these activities into their efforts. PMID:23999670

  2. Reducing Risk with Clinical Decision Support

    PubMed Central

    Maloney, F.L.; Feblowitz, J.; Samal, L.; Sato, L.; Wright, A.

    2014-01-01

    Summary Objective Identify clinical opportunities to intervene to prevent a malpractice event and determine the proportion of malpractice claims potentially preventable by clinical decision support (CDS). Materials and Methods Cross-sectional review of closed malpractice claims over seven years from one malpractice insurance company and seven hospitals in the Boston area. For each event, clinical opportunities to intervene to avert the malpractice event and the presence or absence of CDS that might have a role in preventing the event, were assigned by a panel of expert raters. Compensation paid out to resolve a claim (indemnity), was associated with each CDS type. Results Of the 477 closed malpractice cases, 359 (75.3%) were categorized as substantiated and 195 (54%) had at least one opportunity to intervene. Common opportunities to intervene related to performance of procedure, diagnosis, and fall prevention. We identified at least one CDS type for 63% of substantiated claims. The 41 CDS types identified included clinically significant test result alerting, diagnostic decision support and electronic tracking of instruments. Cases with at least one associated intervention accounted for $40.3 million (58.9%) of indemnity. Discussion CDS systems and other forms of health information technology (HIT) are expected to improve quality of care, but their potential to mitigate risk had not previously been quantified. Our results suggest that, in addition to their known benefits for quality and safety, CDS systems within HIT have a potential role in decreasing malpractice payments. Conclusion More than half of malpractice events and over $40 million of indemnity were potentially preventable with CDS. PMID:25298814

  3. Enhancements in healthcare information technology systems: customizing vendor-supplied clinical decision support for a high-risk patient population.

    PubMed

    Tiwari, Ruchi; Tsapepas, Demetra S; Powell, Jaclyn T; Martin, Spencer T

    2013-01-01

    Healthcare organizations continue to adopt information technologies with clinical decision support (CDS) to prevent potential medication-related adverse drug events. End-users who are unfamiliar with certain high-risk patient populations are at an increased risk of unknowingly causing medication errors. The following case describes a heart transplant recipient exposed to supra-therapeutic concentrations of tacrolimus during co-administration of ritonavir as a result of vendor supplied CDS tools that omitted an interaction alert. After review of 4692 potential tacrolimus-based DDIs between 329 different drug pairs supplied by vendor CDS, the severity of 20 DDIs were downgraded and the severity of 62 were upgraded. The need for institution-specific customization of vendor-provided CDS is paramount to ensure avoidance of medication errors. Individualized care will become more important as patient populations and institutions become more specialized. In the future, vendors providing integrated CDS tools must be proactive in developing institution-specific and easily customizable CDS tools.

  4. Enhancements in healthcare information technology systems: customizing vendor-supplied clinical decision support for a high-risk patient population

    PubMed Central

    Tiwari, Ruchi; Tsapepas, Demetra S; Powell, Jaclyn T

    2013-01-01

    Healthcare organizations continue to adopt information technologies with clinical decision support (CDS) to prevent potential medication-related adverse drug events. End-users who are unfamiliar with certain high-risk patient populations are at an increased risk of unknowingly causing medication errors. The following case describes a heart transplant recipient exposed to supra-therapeutic concentrations of tacrolimus during co-administration of ritonavir as a result of vendor supplied CDS tools that omitted an interaction alert. After review of 4692 potential tacrolimus-based DDIs between 329 different drug pairs supplied by vendor CDS, the severity of 20 DDIs were downgraded and the severity of 62 were upgraded. The need for institution-specific customization of vendor-provided CDS is paramount to ensure avoidance of medication errors. Individualized care will become more important as patient populations and institutions become more specialized. In the future, vendors providing integrated CDS tools must be proactive in developing institution-specific and easily customizable CDS tools. PMID:22813760

  5. Analysis of Nursing Clinical Decision Support Requests and Strategic Plan in a Large Academic Health System

    PubMed Central

    Bavuso, Karen; Bouyer-Ferullo, Sharon; Goldsmith, Denise; Fairbanks, Amanda; Gesner, Emily; Lagor, Charles; Collins, Sarah

    2016-01-01

    Summary Objectives To understand requests for nursing Clinical Decision Support (CDS) interventions at a large integrated health system undergoing vendor-based EHR implementation. In addition, to establish a process to guide both short-term implementation and long-term strategic goals to meet nursing CDS needs. Materials and Methods We conducted an environmental scan to understand current state of nursing CDS over three months. The environmental scan consisted of a literature review and an analysis of CDS requests received from across our health system. We identified existing high priority CDS and paper-based tools used in nursing practice at our health system that guide decision-making. Results A total of 46 nursing CDS requests were received. Fifty-six percent (n=26) were specific to a clinical specialty; 22 percent (n=10) were focused on facilitating clinical consults in the inpatient setting. “Risk Assessments/Risk Reduction/Promotion of Healthy Habits” (n=23) was the most requested High Priority Category received for nursing CDS. A continuum of types of nursing CDS needs emerged using the Data-Information-Knowledge-Wisdom Conceptual Framework: 1) facilitating data capture, 2) meeting information needs, 3) guiding knowledge-based decision making, and 4) exposing analytics for wisdom-based clinical interpretation by the nurse. Conclusion Identifying and prioritizing paper-based tools that can be modified into electronic CDS is a challenge. CDS strategy is an evolving process that relies on close collaboration and engagement with clinical sites for short-term implementation and should be incorporated into a long-term strategic plan that can be optimized and achieved overtime. The Data-Information-Knowledge-Wisdom Conceptual Framework in conjunction with the High Priority Categories established may be a useful tool to guide a strategic approach for meeting short-term nursing CDS needs and aligning with the organizational strategic plan. PMID:27437036

  6. Integrative review of clinical decision support for registered nurses in acute care settings.

    PubMed

    Dunn Lopez, Karen; Gephart, Sheila M; Raszewski, Rebecca; Sousa, Vanessa; Shehorn, Lauren E; Abraham, Joanna

    2017-03-01

    To report on the state of the science of clinical decision support (CDS) for hospital bedside nurses. We performed an integrative review of qualitative and quantitative peer-reviewed original research studies using a structured search of PubMed, Embase, Cumulative Index to Nursing and Applied Health Literature (CINAHL), Scopus, Web of Science, and IEEE Xplore (Institute of Electrical and Electronics Engineers Xplore Digital Library). We included articles that reported on CDS targeting bedside nurses and excluded in stages based on rules for titles, abstracts, and full articles. We extracted research design and methods, CDS purpose, electronic health record integration, usability, and process and patient outcomes. Our search yielded 3157 articles. After removing duplicates and applying exclusion rules, 28 articles met the inclusion criteria. The majority of studies were single-site, descriptive or qualitative (43%) or quasi-experimental (36%). There was only 1 randomized controlled trial. The purpose of most CDS was to support diagnostic decision-making (36%), guideline adherence (32%), medication management (29%), and situational awareness (25%). All the studies that included process outcomes (7) and usability outcomes (4) and also had analytic procedures to detect changes in outcomes demonstrated statistically significant improvements. Three of 4 studies that included patient outcomes and also had analytic procedures to detect change showed statistically significant improvements. No negative effects of CDS were found on process, usability, or patient outcomes. Clinical support systems targeting bedside nurses have positive effects on outcomes and hold promise for improving care quality; however, this research is lagging behind studies of CDS targeting medical decision-making in both volume and level of evidence. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Clinical Decision Support: a 25 Year Retrospective and a 25 Year Vision

    PubMed Central

    Sittig, D. F.; Wright, A.

    2016-01-01

    Summary Objective The objective of this review is to summarize the state of the art of clinical decision support (CDS) circa 1990, review progress in the 25 year interval from that time, and provide a vision of what CDS might look like 25 years hence, or circa 2040. Method Informal review of the medical literature with iterative review and discussion among the authors to arrive at six axes (data, knowledge, inference, architecture and technology, implementation and integration, and users) to frame the review and discussion of selected barriers and facilitators to the effective use of CDS. Result In each of the six axes, significant progress has been made. Key advances in structuring and encoding standardized data with an increased availability of data, development of knowledge bases for CDS, and improvement of capabilities to share knowledge artifacts, explosion of methods analyzing and inferring from clinical data, evolution of information technologies and architectures to facilitate the broad application of CDS, improvement of methods to implement CDS and integrate CDS into the clinical workflow, and increasing sophistication of the end-user, all have played a role in improving the effective use of CDS in healthcare delivery. Conclusion CDS has evolved dramatically over the past 25 years and will likely evolve just as dramatically or more so over the next 25 years. Increasingly, the clinical encounter between a clinician and a patient will be supported by a wide variety of cognitive aides to support diagnosis, treatment, care-coordination, surveillance and prevention, and health maintenance or wellness. PMID:27488402

  8. Use of a remote clinical decision support service for a multicenter trial to implement prediction rules for children with minor blunt head trauma.

    PubMed

    Goldberg, Howard S; Paterno, Marilyn D; Grundmeier, Robert W; Rocha, Beatriz H; Hoffman, Jeffrey M; Tham, Eric; Swietlik, Marguerite; Schaeffer, Molly H; Pabbathi, Deepika; Deakyne, Sara J; Kuppermann, Nathan; Dayan, Peter S

    2016-03-01

    To evaluate the architecture, integration requirements, and execution characteristics of a remote clinical decision support (CDS) service used in a multicenter clinical trial. The trial tested the efficacy of implementing brain injury prediction rules for children with minor blunt head trauma. We integrated the Epic(®) electronic health record (EHR) with the Enterprise Clinical Rules Service (ECRS), a web-based CDS service, at two emergency departments. Patterns of CDS review included either a delayed, near-real-time review, where the physician viewed CDS recommendations generated by the nursing assessment, or a real-time review, where the physician viewed recommendations generated by their own documentation. A backstopping, vendor-based CDS triggered with zero delay when no recommendation was available in the EHR from the web-service. We assessed the execution characteristics of the integrated system and the source of the generated recommendations viewed by physicians. The ECRS mean execution time was 0.74 ±0.72 s. Overall execution time was substantially different at the two sites, with mean total transaction times of 19.67 and 3.99 s. Of 1930 analyzed transactions from the two sites, 60% (310/521) of all physician documentation-initiated recommendations and 99% (1390/1409) of all nurse documentation-initiated recommendations originated from the remote web service. The remote CDS system was the source of recommendations in more than half of the real-time cases and virtually all the near-real-time cases. Comparisons are limited by allowable variation in user workflow and resolution of the EHR clock. With maturation and adoption of standards for CDS services, remote CDS shows promise to decrease time-to-trial for multicenter evaluations of candidate decision support interventions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Design of decision support interventions for medication prescribing.

    PubMed

    Horsky, Jan; Phansalkar, Shobha; Desai, Amrita; Bell, Douglas; Middleton, Blackford

    2013-06-01

    Describe optimal design attributes of clinical decision support (CDS) interventions for medication prescribing, emphasizing perceptual, cognitive and functional characteristics that improve human-computer interaction (HCI) and patient safety. Findings from published reports on success, failures and lessons learned during implementation of CDS systems were reviewed and interpreted with regard to HCI and software usability principles. We then formulated design recommendations for CDS alerts that would reduce unnecessary workflow interruptions and allow clinicians to make informed decisions quickly, accurately and without extraneous cognitive and interactive effort. Excessive alerting that tends to distract clinicians rather than provide effective CDS can be reduced by designing only high severity alerts as interruptive dialog boxes and less severe warnings without explicit response requirement, by curating system knowledge bases to suppress warnings with low clinical utility and by integrating contextual patient data into the decision logic. Recommended design principles include parsimonious and consistent use of color and language, minimalist approach to the layout of information and controls, the use of font attributes to convey hierarchy and visual prominence of important data over supporting information, the inclusion of relevant patient data in the context of the alert and allowing clinicians to respond with one or two clicks. Although HCI and usability principles are well established and robust, CDS and EHR system interfaces rarely conform to the best known design conventions and are seldom conceived and designed well enough to be truly versatile and dependable tools. These relatively novel interventions still require careful monitoring, research and analysis of its track record to mature. Clarity and specificity of alert content and optimal perceptual and cognitive attributes, for example, are essential for providing effective decision support to clinicians. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Boosting Quality Registries with Clinical Decision Support Functionality*. User Acceptance of a Prototype Applied to HIV/TB Drug Therapy.

    PubMed

    Wannheden, Carolina; Hvitfeldt-Forsberg, Helena; Eftimovska, Elena; Westling, Katarina; Ellenius, Johan

    2017-08-11

    The care of HIV-related tuberculosis (HIV/TB) is complex and challenging. Clinical decision support (CDS) systems can contribute to improve quality of care, but more knowledge is needed on factors determining user acceptance of CDS. To analyze physicians' and nurses' acceptance of a CDS prototype for evidence-based drug therapy recommendations for HIV/TB treatment. Physicians and nurses were involved in designing a CDS prototype intended for future integration with the Swedish national HIV quality registry. Focus group evaluation was performed with ten nurses and four physicians, respectively. The Unified Theory of Acceptance and Use of Technology (UTAUT) was used to analyze acceptance. We identified several potential benefits with the CDS prototype as well as some concerns that could be addressed by redesign. There was also concern about dependence on physician attitudes, as well as technical, organizational, and legal issues. Acceptance evaluation at a prototype stage provided rich data to improve the future design of a CDS prototype. Apart from design and development efforts, substantial organizational efforts are needed to enable the implementation and maintenance of a future CDS system.

  11. Clinical decision support alert malfunctions: analysis and empirically derived taxonomy.

    PubMed

    Wright, Adam; Ai, Angela; Ash, Joan; Wiesen, Jane F; Hickman, Thu-Trang T; Aaron, Skye; McEvoy, Dustin; Borkowsky, Shane; Dissanayake, Pavithra I; Embi, Peter; Galanter, William; Harper, Jeremy; Kassakian, Steve Z; Ramoni, Rachel; Schreiber, Richard; Sirajuddin, Anwar; Bates, David W; Sittig, Dean F

    2018-05-01

    To develop an empirically derived taxonomy of clinical decision support (CDS) alert malfunctions. We identified CDS alert malfunctions using a mix of qualitative and quantitative methods: (1) site visits with interviews of chief medical informatics officers, CDS developers, clinical leaders, and CDS end users; (2) surveys of chief medical informatics officers; (3) analysis of CDS firing rates; and (4) analysis of CDS overrides. We used a multi-round, manual, iterative card sort to develop a multi-axial, empirically derived taxonomy of CDS malfunctions. We analyzed 68 CDS alert malfunction cases from 14 sites across the United States with diverse electronic health record systems. Four primary axes emerged: the cause of the malfunction, its mode of discovery, when it began, and how it affected rule firing. Build errors, conceptualization errors, and the introduction of new concepts or terms were the most frequent causes. User reports were the predominant mode of discovery. Many malfunctions within our database caused rules to fire for patients for whom they should not have (false positives), but the reverse (false negatives) was also common. Across organizations and electronic health record systems, similar malfunction patterns recurred. Challenges included updates to code sets and values, software issues at the time of system upgrades, difficulties with migration of CDS content between computing environments, and the challenge of correctly conceptualizing and building CDS. CDS alert malfunctions are frequent. The empirically derived taxonomy formalizes the common recurring issues that cause these malfunctions, helping CDS developers anticipate and prevent CDS malfunctions before they occur or detect and resolve them expediently.

  12. Key principles for a national clinical decision support knowledge sharing framework: synthesis of insights from leading subject matter experts.

    PubMed

    Kawamoto, Kensaku; Hongsermeier, Tonya; Wright, Adam; Lewis, Janet; Bell, Douglas S; Middleton, Blackford

    2013-01-01

    To identify key principles for establishing a national clinical decision support (CDS) knowledge sharing framework. As part of an initiative by the US Office of the National Coordinator for Health IT (ONC) to establish a framework for national CDS knowledge sharing, key stakeholders were identified. Stakeholders' viewpoints were obtained through surveys and in-depth interviews, and findings and relevant insights were summarized. Based on these insights, key principles were formulated for establishing a national CDS knowledge sharing framework. Nineteen key stakeholders were recruited, including six executives from electronic health record system vendors, seven executives from knowledge content producers, three executives from healthcare provider organizations, and three additional experts in clinical informatics. Based on these stakeholders' insights, five key principles were identified for effectively sharing CDS knowledge nationally. These principles are (1) prioritize and support the creation and maintenance of a national CDS knowledge sharing framework; (2) facilitate the development of high-value content and tooling, preferably in an open-source manner; (3) accelerate the development or licensing of required, pragmatic standards; (4) acknowledge and address medicolegal liability concerns; and (5) establish a self-sustaining business model. Based on the principles identified, a roadmap for national CDS knowledge sharing was developed through the ONC's Advancing CDS initiative. The study findings may serve as a useful guide for ongoing activities by the ONC and others to establish a national framework for sharing CDS knowledge and improving clinical care.

  13. A Service Oriented Architecture Approach to Achieve Interoperability between Immunization Information Systems in Iran

    PubMed Central

    Hosseini, Masoud; Ahmadi, Maryam; Dixon, Brian E.

    2014-01-01

    Clinical decision support (CDS) systems can support vaccine forecasting and immunization reminders; however, immunization decision-making requires data from fragmented, independent systems. Interoperability and accurate data exchange between immunization information systems (IIS) is an essential factor to utilize Immunization CDS systems. Service oriented architecture (SOA) and Health Level 7 (HL7) are dominant standards for web-based exchange of clinical information. We implemented a system based on SOA and HL7 v3 to support immunization CDS in Iran. We evaluated system performance by exchanging 1500 immunization records for roughly 400 infants between two IISs. System turnaround time is less than a minute for synchronous operation calls and the retrieved immunization history of infants were always identical in different systems. CDS generated reports were accordant to immunization guidelines and the calculations for next visit times were accurate. Interoperability is rare or nonexistent between IIS. Since inter-state data exchange is rare in United States, this approach could be a good prototype to achieve interoperability of immunization information. PMID:25954452

  14. A Service Oriented Architecture Approach to Achieve Interoperability between Immunization Information Systems in Iran.

    PubMed

    Hosseini, Masoud; Ahmadi, Maryam; Dixon, Brian E

    2014-01-01

    Clinical decision support (CDS) systems can support vaccine forecasting and immunization reminders; however, immunization decision-making requires data from fragmented, independent systems. Interoperability and accurate data exchange between immunization information systems (IIS) is an essential factor to utilize Immunization CDS systems. Service oriented architecture (SOA) and Health Level 7 (HL7) are dominant standards for web-based exchange of clinical information. We implemented a system based on SOA and HL7 v3 to support immunization CDS in Iran. We evaluated system performance by exchanging 1500 immunization records for roughly 400 infants between two IISs. System turnaround time is less than a minute for synchronous operation calls and the retrieved immunization history of infants were always identical in different systems. CDS generated reports were accordant to immunization guidelines and the calculations for next visit times were accurate. Interoperability is rare or nonexistent between IIS. Since inter-state data exchange is rare in United States, this approach could be a good prototype to achieve interoperability of immunization information.

  15. Using Computational Modeling to Assess the Impact of Clinical Decision Support on Cancer Screening within Community Health Centers

    PubMed Central

    Carney, Timothy Jay; Morgan, Geoffrey P.; Jones, Josette; McDaniel, Anna M.; Weaver, Michael; Weiner, Bryan; Haggstrom, David A.

    2014-01-01

    Our conceptual model demonstrates our goal to investigate the impact of clinical decision support (CDS) utilization on cancer screening improvement strategies in the community health care (CHC) setting. We employed a dual modeling technique using both statistical and computational modeling to evaluate impact. Our statistical model used the Spearman’s Rho test to evaluate the strength of relationship between our proximal outcome measures (CDS utilization) against our distal outcome measure (provider self-reported cancer screening improvement). Our computational model relied on network evolution theory and made use of a tool called Construct-TM to model the use of CDS measured by the rate of organizational learning. We employed the use of previously collected survey data from community health centers Cancer Health Disparities Collaborative (HDCC). Our intent is to demonstrate the added valued gained by using a computational modeling tool in conjunction with a statistical analysis when evaluating the impact a health information technology, in the form of CDS, on health care quality process outcomes such as facility-level screening improvement. Significant simulated disparities in organizational learning over time were observed between community health centers beginning the simulation with high and low clinical decision support capability. PMID:24953241

  16. Development of a SNOMED CT based national medication decision support system.

    PubMed

    Greibe, Kell

    2013-01-01

    Physicians often lack the time to familiarize themselves with the details of particular allergies or other drug restrictions. Clinical Decision Support (CDS), based on a structured terminology as SNOMED CT (SCT), can help physicians get an overview, by automatically alerting allergy, interactions and other important information. The centralized CDS platform based on SCT, controls Allergy, Interactions, Risk Situation Drugs and Max Dose restrictions by the help of databases developed for these specific purposes. The CDS will respond to automatic web service requests from the hospital or GP electronic medication system (EMS) during prescription, and return alerts and information. The CDS also contains a Physicians Preference Database where the physicians individually can set which kind of alerts they want to see. The result is clinically useful information physicians can use as a base for a more effective and safer treatment, without developing alert fatigue.

  17. Evaluation of medium-term consequences of implementing commercial computerized physician order entry and clinical decision support prescribing systems in two ‘early adopter’ hospitals

    PubMed Central

    Cresswell, Kathrin M; Bates, David W; Williams, Robin; Morrison, Zoe; Slee, Ann; Coleman, Jamie; Robertson, Ann; Sheikh, Aziz

    2014-01-01

    Objective To understand the medium-term consequences of implementing commercially procured computerized physician order entry (CPOE) and clinical decision support (CDS) systems in ‘early adopter’ hospitals. Materials and methods In-depth, qualitative case study in two hospitals using a CPOE or a CDS system for at least 2 years. Both hospitals had implemented commercially available systems. Hospital A had implemented a CPOE system (with basic decision support), whereas hospital B invested additional resources in a CDS system that facilitated order entry but which was integrated with electronic health records and offered more advanced CDS. We used a combination of documentary analysis of the implementation plans, audiorecorded semistructured interviews with system users, and observations of strategic meetings and systems usage. Results We collected 11 documents, conducted 43 interviews, and conducted a total of 21.5 h of observations. We identified three major themes: (1) impacts on individual users, including greater legibility of prescriptions, but also some accounts of increased workloads; (2) the introduction of perceived new safety risks related to accessibility and usability of hardware and software, with users expressing concerns that some problems such as duplicate prescribing were more likely to occur; and (3) realizing organizational benefits through secondary uses of data. Conclusions We identified little difference in the medium-term consequences of a CPOE and a CDS system. It is important that future studies investigate the medium- and longer-term consequences of CPOE and CDS systems in a wider range of hospitals. PMID:24431334

  18. Making pharmacogenomic-based prescribing alerts more effective: A scenario-based pilot study with physicians.

    PubMed

    Overby, Casey Lynnette; Devine, Emily Beth; Abernethy, Neil; McCune, Jeannine S; Tarczy-Hornoch, Peter

    2015-06-01

    To facilitate personalized drug dosing (PDD), this pilot study explored the communication effectiveness and clinical impact of using a prototype clinical decision support (CDS) system embedded in an electronic health record (EHR) to deliver pharmacogenomic (PGx) information to physicians. We employed a conceptual framework and measurement model to access the impact of physician characteristics (previous experience, awareness, relative advantage, perceived usefulness), technology characteristics (methods of implementation-semi-active/active, actionability-low/high) and a task characteristic (drug prescribed) on communication effectiveness (usefulness, confidence in prescribing decision), and clinical impact (uptake, prescribing intent, change in drug dosing). Physicians performed prescribing tasks using five simulated clinical case scenarios, presented in random order within the prototype PGx-CDS system. Twenty-two physicians completed the study. The proportion of physicians that saw a relative advantage to using PGx-CDS was 83% at the start and 94% at the conclusion of our study. Physicians used semi-active alerts 74-88% of the time. There was no association between previous experience with, awareness of, and belief in a relative advantage of using PGx-CDS and improved uptake. The proportion of physicians reporting confidence in their prescribing decisions decreased significantly after using the prototype PGx-CDS system (p=0.02). Despite decreases in confidence, physicians perceived a relative advantage to using PGx-CDS, viewed semi-active alerts on most occasions, and more frequently changed doses toward doses supported by published evidence. Specifically, sixty-five percent of physicians reduced their dosing, significantly for capecitabine (p=0.002) and mercaptopurine/thioguanine (p=0.03). These findings suggest a need to improve our prototype such that PGx CDS content is more useful and delivered in a way that improves physician's confidence in their prescribing decisions. The greatest increases in communication effectiveness and clinical impact of PGx-CDS are likely to be realized through continued focus on content, content delivery, and tailoring to physician characteristics. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Key principles for a national clinical decision support knowledge sharing framework: synthesis of insights from leading subject matter experts

    PubMed Central

    Hongsermeier, Tonya; Wright, Adam; Lewis, Janet; Bell, Douglas S; Middleton, Blackford

    2013-01-01

    Objective To identify key principles for establishing a national clinical decision support (CDS) knowledge sharing framework. Materials and methods As part of an initiative by the US Office of the National Coordinator for Health IT (ONC) to establish a framework for national CDS knowledge sharing, key stakeholders were identified. Stakeholders' viewpoints were obtained through surveys and in-depth interviews, and findings and relevant insights were summarized. Based on these insights, key principles were formulated for establishing a national CDS knowledge sharing framework. Results Nineteen key stakeholders were recruited, including six executives from electronic health record system vendors, seven executives from knowledge content producers, three executives from healthcare provider organizations, and three additional experts in clinical informatics. Based on these stakeholders' insights, five key principles were identified for effectively sharing CDS knowledge nationally. These principles are (1) prioritize and support the creation and maintenance of a national CDS knowledge sharing framework; (2) facilitate the development of high-value content and tooling, preferably in an open-source manner; (3) accelerate the development or licensing of required, pragmatic standards; (4) acknowledge and address medicolegal liability concerns; and (5) establish a self-sustaining business model. Discussion Based on the principles identified, a roadmap for national CDS knowledge sharing was developed through the ONC's Advancing CDS initiative. Conclusion The study findings may serve as a useful guide for ongoing activities by the ONC and others to establish a national framework for sharing CDS knowledge and improving clinical care. PMID:22865671

  20. Clinical Decision Support-based Quality Measurement (CDS-QM) Framework: Prototype Implementation, Evaluation, and Future Directions

    PubMed Central

    Kukhareva, Polina V; Kawamoto, Kensaku; Shields, David E; Barfuss, Darryl T; Halley, Anne M; Tippetts, Tyler J; Warner, Phillip B; Bray, Bruce E; Staes, Catherine J

    2014-01-01

    Electronic quality measurement (QM) and clinical decision support (CDS) are closely related but are typically implemented independently, resulting in significant duplication of effort. While it seems intuitive that technical approaches could be re-used across these two related use cases, such reuse is seldom reported in the literature, especially for standards-based approaches. Therefore, we evaluated the feasibility of using a standards-based CDS framework aligned with anticipated EHR certification criteria to implement electronic QM. The CDS-QM framework was used to automate a complex national quality measure (SCIP-VTE-2) at an academic healthcare system which had previously relied on time-consuming manual chart abstractions. Compared with 305 manually-reviewed reference cases, the recall of automated measurement was 100%. The precision was 96.3% (CI:92.6%-98.5%) for ascertaining the denominator and 96.2% (CI:92.3%-98.4%) for the numerator. We therefore validated that a standards-based CDS-QM framework can successfully enable automated QM, and we identified benefits and challenges with this approach. PMID:25954389

  1. Governance for clinical decision support: case studies and recommended practices from leading institutions

    PubMed Central

    Sittig, Dean F; Ash, Joan S; Bates, David W; Feblowitz, Joshua; Fraser, Greg; Maviglia, Saverio M; McMullen, Carmit; Nichol, W Paul; Pang, Justine E; Starmer, Jack; Middleton, Blackford

    2011-01-01

    Objective Clinical decision support (CDS) is a powerful tool for improving healthcare quality and ensuring patient safety; however, effective implementation of CDS requires effective clinical and technical governance structures. The authors sought to determine the range and variety of these governance structures and identify a set of recommended practices through observational study. Design Three site visits were conducted at institutions across the USA to learn about CDS capabilities and processes from clinical, technical, and organizational perspectives. Based on the results of these visits, written questionnaires were sent to the three institutions visited and two additional sites. Together, these five organizations encompass a variety of academic and community hospitals as well as small and large ambulatory practices. These organizations use both commercially available and internally developed clinical information systems. Measurements Characteristics of clinical information systems and CDS systems used at each site as well as governance structures and content management approaches were identified through extensive field interviews and follow-up surveys. Results Six recommended practices were identified in the area of governance, and four were identified in the area of content management. Key similarities and differences between the organizations studied were also highlighted. Conclusion Each of the five sites studied contributed to the recommended practices presented in this paper for CDS governance. Since these strategies appear to be useful at a diverse range of institutions, they should be considered by any future implementers of decision support. PMID:21252052

  2. Automating Performance Measures and Clinical Practice Guidelines: Differences and Complementarities.

    PubMed

    Tu, Samson W; Martins, Susana; Oshiro, Connie; Yuen, Kaeli; Wang, Dan; Robinson, Amy; Ashcraft, Michael; Heidenreich, Paul A; Goldstein, Mary K

    2016-01-01

    Through close analysis of two pairs of systems that implement the automated evaluation of performance measures (PMs) and guideline-based clinical decision support (CDS), we contrast differences in their knowledge encoding and necessary changes to a CDS system that provides management recommendations for patients failing performance measures. We trace the sources of differences to the implementation environments and goals of PMs and CDS.

  3. Evaluation of RxNorm for Medication Clinical Decision Support.

    PubMed

    Freimuth, Robert R; Wix, Kelly; Zhu, Qian; Siska, Mark; Chute, Christopher G

    2014-01-01

    We evaluated the potential use of RxNorm to provide standardized representations of generic drug name and route of administration to facilitate management of drug lists for clinical decision support (CDS) rules. We found a clear representation of generic drug name but not route of administration. We identified several issues related to data quality, including erroneous or missing defined relationships, and the use of different concept hierarchies to represent the same drug. More importantly, we found extensive semantic precoordination of orthogonal concepts related to route and dose form, which would complicate the use of RxNorm for drug-based CDS. This study demonstrated that while RxNorm is a valuable resource for the standardization of medications used in clinical practice, additional work is required to enhance the terminology so that it can support expanded use cases, such as managing drug lists for CDS.

  4. Evaluation of RxNorm for Medication Clinical Decision Support

    PubMed Central

    Freimuth, Robert R.; Wix, Kelly; Zhu, Qian; Siska, Mark; Chute, Christopher G.

    2014-01-01

    We evaluated the potential use of RxNorm to provide standardized representations of generic drug name and route of administration to facilitate management of drug lists for clinical decision support (CDS) rules. We found a clear representation of generic drug name but not route of administration. We identified several issues related to data quality, including erroneous or missing defined relationships, and the use of different concept hierarchies to represent the same drug. More importantly, we found extensive semantic precoordination of orthogonal concepts related to route and dose form, which would complicate the use of RxNorm for drug-based CDS. This study demonstrated that while RxNorm is a valuable resource for the standardization of medications used in clinical practice, additional work is required to enhance the terminology so that it can support expanded use cases, such as managing drug lists for CDS. PMID:25954360

  5. Thinking Together: Modeling Clinical Decision-Support as a Sociotechnical System

    PubMed Central

    Hussain, Mustafa I.; Reynolds, Tera L.; Mousavi, Fatemeh E.; Chen, Yunan; Zheng, Kai

    2017-01-01

    Computerized clinical decision-support systems are members of larger sociotechnical systems, composed of human and automated actors, who send, receive, and manipulate artifacts. Sociotechnical consideration is rare in the literature. This makes it difficult to comparatively evaluate the success of CDS implementations, and it may also indicate that sociotechnical context receives inadequate consideration in practice. To facilitate sociotechnical consideration, we developed the Thinking Together model, a flexible diagrammatical means of representing CDS systems as sociotechnical systems. To develop this model, we examined the literature with the lens of Distributed Cognition (DCog) theory. We then present two case studies of vastly different CDSSs, one almost fully automated and the other with minimal automation, to illustrate the flexibility of the Thinking Together model. We show that this model, informed by DCog and the CDS literature, are capable of supporting both research, by enabling comparative evaluation, and practice, by facilitating explicit sociotechnical planning and communication. PMID:29854164

  6. Design, Development, and Initial Evaluation of a Terminology for Clinical Decision Support and Electronic Clinical Quality Measurement.

    PubMed

    Lin, Yanhua; Staes, Catherine J; Shields, David E; Kandula, Vijay; Welch, Brandon M; Kawamoto, Kensaku

    2015-01-01

    When coupled with a common information model, a common terminology for clinical decision support (CDS) and electronic clinical quality measurement (eCQM) could greatly facilitate the distributed development and sharing of CDS and eCQM knowledge resources. To enable such scalable knowledge authoring and sharing, we systematically developed an extensible and standards-based terminology for CDS and eCQM in the context of the HL7 Virtual Medical Record (vMR) information model. The development of this terminology entailed three steps: (1) systematic, physician-curated concept identification from sources such as the Health Information Technology Standards Panel (HITSP) and the SNOMED-CT CORE problem list; (2) concept de-duplication leveraging the Unified Medical Language System (UMLS) MetaMap and Metathesaurus; and (3) systematic concept naming using standard terminologies and heuristic algorithms. This process generated 3,046 concepts spanning 68 domains. Evaluation against representative CDS and eCQM resources revealed approximately 50-70% concept coverage, indicating the need for continued expansion of the terminology.

  7. Improving Performance on Preventive Health Quality Measures Using Clinical Decision Support to Capture Care Done Elsewhere and Patient Exceptions.

    PubMed

    Bowen, Michael E; Bhat, Deepa; Fish, Jason; Moran, Brett; Howell-Stampley, Temple; Kirk, Lynne; Persell, Stephen D; Halm, Ethan A

    Preventive services required for performance measurement often are completed in outside health systems and not captured in electronic medical records (EMRs). A before-after study was conducted to examine the ability of clinical decision support (CDS) to improve performance on preventive quality measures, capture clinician-reported services completed elsewhere, and patient/medical exceptions and to describe their impact on quality measurement. CDS improved performance on colorectal cancer screening, osteoporosis screening, and pneumococcal vaccination measures ( P < .05) but not breast or cervical cancer screening. CDS captured clinician-reported services completed elsewhere (2% to 10%) and patient/medical exceptions (<3%). Compared to measures using only within-system data, including services completed elsewhere in the numerator improved performance: pneumococcal vaccine (73% vs 82%); breast (69% vs 75%), colorectal (58% vs 70%), and cervical cancer (53% vs 62%); and osteoporosis (72% vs 75%) screening ( P < .05). Visit-based CDS can capture clinician-reported preventive services, and accounting for services completed elsewhere improves performance on quality measures.

  8. Design, Development, and Initial Evaluation of a Terminology for Clinical Decision Support and Electronic Clinical Quality Measurement

    PubMed Central

    Lin, Yanhua; Staes, Catherine J; Shields, David E; Kandula, Vijay; Welch, Brandon M; Kawamoto, Kensaku

    2015-01-01

    When coupled with a common information model, a common terminology for clinical decision support (CDS) and electronic clinical quality measurement (eCQM) could greatly facilitate the distributed development and sharing of CDS and eCQM knowledge resources. To enable such scalable knowledge authoring and sharing, we systematically developed an extensible and standards-based terminology for CDS and eCQM in the context of the HL7 Virtual Medical Record (vMR) information model. The development of this terminology entailed three steps: (1) systematic, physician-curated concept identification from sources such as the Health Information Technology Standards Panel (HITSP) and the SNOMED-CT CORE problem list; (2) concept de-duplication leveraging the Unified Medical Language System (UMLS) MetaMap and Metathesaurus; and (3) systematic concept naming using standard terminologies and heuristic algorithms. This process generated 3,046 concepts spanning 68 domains. Evaluation against representative CDS and eCQM resources revealed approximately 50–70% concept coverage, indicating the need for continued expansion of the terminology. PMID:26958220

  9. A systematic review of near real-time and point-of-care clinical decision support in anesthesia information management systems.

    PubMed

    Simpao, Allan F; Tan, Jonathan M; Lingappan, Arul M; Gálvez, Jorge A; Morgan, Sherry E; Krall, Michael A

    2017-10-01

    Anesthesia information management systems (AIMS) are sophisticated hardware and software technology solutions that can provide electronic feedback to anesthesia providers. This feedback can be tailored to provide clinical decision support (CDS) to aid clinicians with patient care processes, documentation compliance, and resource utilization. We conducted a systematic review of peer-reviewed articles on near real-time and point-of-care CDS within AIMS using the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols. Studies were identified by searches of the electronic databases Medline and EMBASE. Two reviewers screened studies based on title, abstract, and full text. Studies that were similar in intervention and desired outcome were grouped into CDS categories. Three reviewers graded the evidence within each category. The final analysis included 25 articles on CDS as implemented within AIMS. CDS categories included perioperative antibiotic prophylaxis, post-operative nausea and vomiting prophylaxis, vital sign monitors and alarms, glucose management, blood pressure management, ventilator management, clinical documentation, and resource utilization. Of these categories, the reviewers graded perioperative antibiotic prophylaxis and clinical documentation as having strong evidence per the peer reviewed literature. There is strong evidence for the inclusion of near real-time and point-of-care CDS in AIMS to enhance compliance with perioperative antibiotic prophylaxis and clinical documentation. Additional research is needed in many other areas of AIMS-based CDS.

  10. Evaluation of prescriber responses to pharmacogenomics clinical decision support for thiopurine S-methyltransferase testing.

    PubMed

    Ubanyionwu, Samuel; Formea, Christine M; Anderson, Benjamin; Wix, Kelly; Dierkhising, Ross; Caraballo, Pedro J

    2018-02-15

    Results of a study of prescribers' responses to a pharmacogenomics-based clinical decision support (CDS) alert designed to prompt thiopurine S -methyltransferase (TPMT) status testing are reported. A single-center, retrospective, chart review-based study was conducted to evaluate prescriber compliance with a pretest CDS alert that warned of potential thiopurine drug toxicity resulting from deficient TPMT activity due to TPMT gene polymorphism. The CDS alert was triggered when prescribers ordered thiopurine drugs for patients whose records did not indicate TPMT status or when historical thiopurine use was documented in the electronic health record. The alert pop-up also provided a link to online educational resources to guide thiopurine dosing calculations. During the 9-month study period, 500 CDS alerts were generated: in 101 cases (20%), TPMT phenotyping or TPMT genotyping was ordered; in 399 cases (80%), testing was not ordered. Multivariable regression analysis indicated that documentation of historical thiopurine use was the only independent predictor of test ordering. Among the 99 patients tested subsequent to CDS alerts, 70 (71%) had normal TPMT activity, 29 (29%) had intermediate activity, and none had deficient activity. The online resources provided thiopurine dosing recommendations applicable to 24 patients, but only 3 were prescribed guideline-supported doses after CDS alerts. The pretest CDS rule resulted in a large proportion of neglected alerts due to poor alerting accuracy and consequent alert fatigue. Prescriber usage of online thiopurine dosing resources was low. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  11. A Clinical Decision Support Engine Based on a National Medication Repository for the Detection of Potential Duplicate Medications: Design and Evaluation

    PubMed Central

    Yang, Cheng-Yi; Lo, Yu-Sheng; Chen, Ray-Jade

    2018-01-01

    Background A computerized physician order entry (CPOE) system combined with a clinical decision support system can reduce duplication of medications and thus adverse drug reactions. However, without infrastructure that supports patients’ integrated medication history across health care facilities nationwide, duplication of medication can still occur. In Taiwan, the National Health Insurance Administration has implemented a national medication repository and Web-based query system known as the PharmaCloud, which allows physicians to access their patients’ medication records prescribed by different health care facilities across Taiwan. Objective This study aimed to develop a scalable, flexible, and thematic design-based clinical decision support (CDS) engine, which integrates a national medication repository to support CPOE systems in the detection of potential duplication of medication across health care facilities, as well as to analyze its impact on clinical encounters. Methods A CDS engine was developed that can download patients’ up-to-date medication history from the PharmaCloud and support a CPOE system in the detection of potential duplicate medications. When prescribing a medication order using the CPOE system, a physician receives an alert if there is a potential duplicate medication. To investigate the impact of the CDS engine on clinical encounters in outpatient services, a clinical encounter log was created to collect information about time, prescribed drugs, and physicians’ responses to handling the alerts for each encounter. Results The CDS engine was installed in a teaching affiliate hospital, and the clinical encounter log collected information for 3 months, during which a total of 178,300 prescriptions were prescribed in the outpatient departments. In all, 43,844/178,300 (24.59%) patients signed the PharmaCloud consent form allowing their physicians to access their medication history in the PharmaCloud. The rate of duplicate medication was 5.83% (1843/31,614) of prescriptions. When prescribing using the CDS engine, the median encounter time was 4.3 (IQR 2.3-7.3) min, longer than that without using the CDS engine (median 3.6, IQR 2.0-6.3 min). From the physicians’ responses, we found that 42.06% (1908/4536) of the potential duplicate medications were recognized by the physicians and the medication orders were canceled. Conclusions The CDS engine could easily extend functions for detection of adverse drug reactions when more and more electronic health record systems are adopted. Moreover, the CDS engine can retrieve more updated and completed medication histories in the PharmaCloud, so it can have better performance for detection of duplicate medications. Although our CDS engine approach could enhance medication safety, it would make for a longer encounter time. This problem can be mitigated by careful evaluation of adopted solutions for implementation of the CDS engine. The successful key component of a CDS engine is the completeness of the patient’s medication history, thus further research to assess the factors in increasing the PharmaCloud consent rate is required. PMID:29351893

  12. Comparative effectiveness of childhood obesity interventions in pediatric primary care: a cluster-randomized clinical trial.

    PubMed

    Taveras, Elsie M; Marshall, Richard; Kleinman, Ken P; Gillman, Matthew W; Hacker, Karen; Horan, Christine M; Smith, Renata L; Price, Sarah; Sharifi, Mona; Rifas-Shiman, Sheryl L; Simon, Steven R

    2015-06-01

    Evidence of effective treatment of childhood obesity in primary care settings is limited. To examine the extent to which computerized clinical decision support (CDS) delivered to pediatric clinicians at the point of care of obese children, with or without individualized family coaching, improved body mass index (BMI; calculated as weight in kilograms divided by height in meters squared) and quality of care. We conducted a cluster-randomized, 3-arm clinical trial. We enrolled 549 children aged 6 to 12 years with a BMI at the 95% percentile or higher from 14 primary care practices in Massachusetts from October 1, 2011, through June 30, 2012. Patients were followed up for 1 year (last follow-up, August 30, 2013). In intent-to-treat analyses, we used linear mixed-effects models to account for clustering by practice and within each person. In 5 practices randomized to CDS, pediatric clinicians received decision support on obesity management, and patients and their families received an intervention for self-guided behavior change. In 5 practices randomized to CDS + coaching, decision support was augmented by individualized family coaching. The remaining 4 practices were randomized to usual care. Smaller age-associated change in BMI and the Healthcare Effectiveness Data and Information Set (HEDIS) performance measures for obesity during the 1-year follow-up. At baseline, mean (SD) patient age and BMI were 9.8 (1.9) years and 25.8 (4.3), respectively. At 1 year, we obtained BMI from 518 children (94.4%) and HEDIS measures from 491 visits (89.4%). The 3 randomization arms had different effects on BMI over time (P = .04). Compared with the usual care arm, BMI increased less in children in the CDS arm during 1 year (-0.51 [95% CI, -0.91 to -0.11]). The CDS + coaching arm had a smaller magnitude of effect (-0.34 [95% CI, -0.75 to 0.07]). We found substantially greater achievement of childhood obesity HEDIS measures in the CDS arm (adjusted odds ratio, 2.28 [95% CI, 1.15-4.53]) and CDS + coaching arm (adjusted odds ratio, 2.60 [95% CI, 1.25-5.41]) and higher use of HEDIS codes for nutrition or physical activity counseling (CDS arm, 45%; CDS + coaching arm, 25%; P < .001 compared with usual care arm). An intervention that included computerized CDS for pediatric clinicians and support for self-guided behavior change for families resulted in improved childhood BMI. Both interventions improved the quality of care for childhood obesity. clinicaltrials.gov Identifier: NCT01537510.

  13. Outcomes of clinical decision support (CDS) and correlates of CDS use for home care patients with high medication regimen complexity: A randomized trial

    PubMed Central

    McDonald, Margaret V.; Feldman, Penny H.; Barrón-Vayá, Yolanda; Peng, Timothy R.; Sridharan, Sridevi; Pezzin, Liliana E.

    2017-01-01

    Objective To assess the outcomes of a clinical decision support (CDS) intervention designed for home care patients with high medication regimen complexity (MRC) and to examine the correlates of CDS use and its relationship to patient outcomes. Method The intervention randomized nurses upon identification of an eligible patient. The CDS consisted of a computerized algorithm that identified high MRC patients, electronic clinician alerts, and a care management module. Analyses were completed on full intention to treat and intervention group-only samples. Regression-adjusted outcomes were hospitalization, emergency department use and reduction in MRC. Data sources included health records and administrative data. Results Five hundred nurses were randomized with 7,919 of their patients. Approximately 20% of the intervention group was hospitalized versus 21% in the control group; 16.5% of the intervention group had an emergency department visit versus 16.7% in the control group; and 6% in each group dropped below the high MRC threshold. No statistically significant differences were found in the intention to treat analysis. Eighty-two percent of intervention nurses used the CDS but for only 42% of their patients. Among intervention patients, CDS use (versus non-use) was associated with reduced MRC and hospitalization. CDS use was more likely among older nurses, those with higher study-patient caseload and, marginally, among salaried nurses and those with longer tenure. Significant patient characteristics were clinical conditions, payer, episode length, care continuity and race. Conclusion CDS use was limited, thus negating the impact of the intervention overall. The findings on correlates of CDS use and the relationship between CDS use and positive outcomes suggest that CDS use and outcomes could be enhanced by avoiding very short patient lengths of stay, improving continuity of care, increasing reliance on salaried nurses and/or increasing per diem nurses’ incentives to use CDS. PMID:26009977

  14. User Requirements for a Chronic Kidney Disease Clinical Decision Support Tool to Promote Timely Referral.

    PubMed

    Gulla, Joy; Neri, Pamela M; Bates, David W; Samal, Lipika

    2017-05-01

    Timely referral of patients with CKD has been associated with cost and mortality benefits, but referrals are often done too late in the course of the disease. Clinical decision support (CDS) offers a potential solution, but interventions have failed because they were not designed to support the physician workflow. We sought to identify user requirements for a chronic kidney disease (CKD) CDS system to promote timely referral. We interviewed primary care physicians (PCPs) to identify data needs for a CKD CDS system that would encourage timely referral and also gathered information about workflow to assess risk factors for progression of CKD. Interviewees were general internists recruited from a network of 14 primary care clinics affiliated with Brigham and Women's Hospital (BWH). We then performed a qualitative analysis to identify user requirements and system attributes for a CKD CDS system. Of the 12 participants, 25% were women, the mean age was 53 (range 37-82), mean years in clinical practice was 27 (range 11-58). We identified 21 user requirements. Seven of these user requirements were related to support for the referral process workflow, including access to pertinent information and support for longitudinal co-management. Six user requirements were relevant to PCP management of CKD, including management of risk factors for progression, interpretation of biomarkers of CKD severity, and diagnosis of the cause of CKD. Finally, eight user requirements addressed user-centered design of CDS, including the need for actionable information, links to guidelines and reference materials, and visualization of trends. These 21 user requirements can be used to design an intuitive and usable CDS system with the attributes necessary to promote timely referral. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Designing Real-time Decision Support for Trauma Resuscitations

    PubMed Central

    Yadav, Kabir; Chamberlain, James M.; Lewis, Vicki R.; Abts, Natalie; Chawla, Shawn; Hernandez, Angie; Johnson, Justin; Tuveson, Genevieve; Burd, Randall S.

    2016-01-01

    Background Use of electronic clinical decision support (eCDS) has been recommended to improve implementation of clinical decision rules. Many eCDS tools, however, are designed and implemented without taking into account the context in which clinical work is performed. Implementation of the pediatric traumatic brain injury (TBI) clinical decision rule at one Level I pediatric emergency department includes an electronic questionnaire triggered when ordering a head computed tomography using computerized physician order entry (CPOE). Providers use this CPOE tool in less than 20% of trauma resuscitation cases. A human factors engineering approach could identify the implementation barriers that are limiting the use of this tool. Objectives The objective was to design a pediatric TBI eCDS tool for trauma resuscitation using a human factors approach. The hypothesis was that clinical experts will rate a usability-enhanced eCDS tool better than the existing CPOE tool for user interface design and suitability for clinical use. Methods This mixed-methods study followed usability evaluation principles. Pediatric emergency physicians were surveyed to identify barriers to using the existing eCDS tool. Using standard trauma resuscitation protocols, a hierarchical task analysis of pediatric TBI evaluation was developed. Five clinical experts, all board-certified pediatric emergency medicine faculty members, then iteratively modified the hierarchical task analysis until reaching consensus. The software team developed a prototype eCDS display using the hierarchical task analysis. Three human factors engineers provided feedback on the prototype through a heuristic evaluation, and the software team refined the eCDS tool using a rapid prototyping process. The eCDS tool then underwent iterative usability evaluations by the five clinical experts using video review of 50 trauma resuscitation cases. A final eCDS tool was created based on their feedback, with content analysis of the evaluations performed to ensure all concerns were identified and addressed. Results Among 26 EPs (76% response rate), the main barriers to using the existing tool were that the information displayed is redundant and does not fit clinical workflow. After the prototype eCDS tool was developed based on the trauma resuscitation hierarchical task analysis, the human factors engineers rated it to be better than the CPOE tool for nine of 10 standard user interface design heuristics on a three-point scale. The eCDS tool was also rated better for clinical use on the same scale, in 84% of 50 expert–video pairs, and was rated equivalent in the remainder. Clinical experts also rated barriers to use of the eCDS tool as being low. Conclusions An eCDS tool for diagnostic imaging designed using human factors engineering methods has improved perceived usability among pediatric emergency physicians. PMID:26300010

  16. Clinical guideline representation in a CDS: a human information processing method.

    PubMed

    Kilsdonk, Ellen; Riezebos, Rinke; Kremer, Leontien; Peute, Linda; Jaspers, Monique

    2012-01-01

    The Dutch Childhood Oncology Group (DCOG) has developed evidence-based guidelines for screening childhood cancer survivors for possible late complications of treatment. These paper-based guidelines appeared to not suit clinicians' information retrieval strategies; it was thus decided to communicate the guidelines through a Computerized Decision Support (CDS) tool. To ensure high usability of this tool, an analysis of clinicians' cognitive strategies in retrieving information from the paper-based guidelines was used as requirements elicitation method. An information processing model was developed through an analysis of think aloud protocols and used as input for the design of the CDS user interface. Usability analysis of the user interface showed that the navigational structure of the CDS tool fitted well with the clinicians' mental strategies employed in deciding on survivors screening protocols. Clinicians were more efficient and more complete in deciding on patient-tailored screening procedures when supported by the CDS tool than by the paper-based guideline booklet. The think-aloud method provided detailed insight into users' clinical work patterns that supported the design of a highly usable CDS system.

  17. Agile Acceptance Test–Driven Development of Clinical Decision Support Advisories: Feasibility of Using Open Source Software

    PubMed Central

    Baldwin, Krystal L; Kannan, Vaishnavi; Flahaven, Emily L; Parks, Cassandra J; Ott, Jason M; Willett, Duwayne L

    2018-01-01

    Background Moving to electronic health records (EHRs) confers substantial benefits but risks unintended consequences. Modern EHRs consist of complex software code with extensive local configurability options, which can introduce defects. Defects in clinical decision support (CDS) tools are surprisingly common. Feasible approaches to prevent and detect defects in EHR configuration, including CDS tools, are needed. In complex software systems, use of test–driven development and automated regression testing promotes reliability. Test–driven development encourages modular, testable design and expanding regression test coverage. Automated regression test suites improve software quality, providing a “safety net” for future software modifications. Each automated acceptance test serves multiple purposes, as requirements (prior to build), acceptance testing (on completion of build), regression testing (once live), and “living” design documentation. Rapid-cycle development or “agile” methods are being successfully applied to CDS development. The agile practice of automated test–driven development is not widely adopted, perhaps because most EHR software code is vendor-developed. However, key CDS advisory configuration design decisions and rules stored in the EHR may prove amenable to automated testing as “executable requirements.” Objective We aimed to establish feasibility of acceptance test–driven development of clinical decision support advisories in a commonly used EHR, using an open source automated acceptance testing framework (FitNesse). Methods Acceptance tests were initially constructed as spreadsheet tables to facilitate clinical review. Each table specified one aspect of the CDS advisory’s expected behavior. Table contents were then imported into a test suite in FitNesse, which queried the EHR database to automate testing. Tests and corresponding CDS configuration were migrated together from the development environment to production, with tests becoming part of the production regression test suite. Results We used test–driven development to construct a new CDS tool advising Emergency Department nurses to perform a swallowing assessment prior to administering oral medication to a patient with suspected stroke. Test tables specified desired behavior for (1) applicable clinical settings, (2) triggering action, (3) rule logic, (4) user interface, and (5) system actions in response to user input. Automated test suite results for the “executable requirements” are shown prior to building the CDS alert, during build, and after successful build. Conclusions Automated acceptance test–driven development and continuous regression testing of CDS configuration in a commercial EHR proves feasible with open source software. Automated test–driven development offers one potential contribution to achieving high-reliability EHR configuration. Vetting acceptance tests with clinicians elicits their input on crucial configuration details early during initial CDS design and iteratively during rapid-cycle optimization. PMID:29653922

  18. Agile Acceptance Test-Driven Development of Clinical Decision Support Advisories: Feasibility of Using Open Source Software.

    PubMed

    Basit, Mujeeb A; Baldwin, Krystal L; Kannan, Vaishnavi; Flahaven, Emily L; Parks, Cassandra J; Ott, Jason M; Willett, Duwayne L

    2018-04-13

    Moving to electronic health records (EHRs) confers substantial benefits but risks unintended consequences. Modern EHRs consist of complex software code with extensive local configurability options, which can introduce defects. Defects in clinical decision support (CDS) tools are surprisingly common. Feasible approaches to prevent and detect defects in EHR configuration, including CDS tools, are needed. In complex software systems, use of test-driven development and automated regression testing promotes reliability. Test-driven development encourages modular, testable design and expanding regression test coverage. Automated regression test suites improve software quality, providing a "safety net" for future software modifications. Each automated acceptance test serves multiple purposes, as requirements (prior to build), acceptance testing (on completion of build), regression testing (once live), and "living" design documentation. Rapid-cycle development or "agile" methods are being successfully applied to CDS development. The agile practice of automated test-driven development is not widely adopted, perhaps because most EHR software code is vendor-developed. However, key CDS advisory configuration design decisions and rules stored in the EHR may prove amenable to automated testing as "executable requirements." We aimed to establish feasibility of acceptance test-driven development of clinical decision support advisories in a commonly used EHR, using an open source automated acceptance testing framework (FitNesse). Acceptance tests were initially constructed as spreadsheet tables to facilitate clinical review. Each table specified one aspect of the CDS advisory's expected behavior. Table contents were then imported into a test suite in FitNesse, which queried the EHR database to automate testing. Tests and corresponding CDS configuration were migrated together from the development environment to production, with tests becoming part of the production regression test suite. We used test-driven development to construct a new CDS tool advising Emergency Department nurses to perform a swallowing assessment prior to administering oral medication to a patient with suspected stroke. Test tables specified desired behavior for (1) applicable clinical settings, (2) triggering action, (3) rule logic, (4) user interface, and (5) system actions in response to user input. Automated test suite results for the "executable requirements" are shown prior to building the CDS alert, during build, and after successful build. Automated acceptance test-driven development and continuous regression testing of CDS configuration in a commercial EHR proves feasible with open source software. Automated test-driven development offers one potential contribution to achieving high-reliability EHR configuration. Vetting acceptance tests with clinicians elicits their input on crucial configuration details early during initial CDS design and iteratively during rapid-cycle optimization. ©Mujeeb A Basit, Krystal L Baldwin, Vaishnavi Kannan, Emily L Flahaven, Cassandra J Parks, Jason M Ott, Duwayne L Willett. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 13.04.2018.

  19. Physician Attitudes toward Adopting Genome-Guided Prescribing through Clinical Decision Support

    PubMed Central

    Overby, Casey Lynnette; Erwin, Angelika Ludtke; Abul-Husn, Noura S.; Ellis, Stephen B.; Scott, Stuart A.; Obeng, Aniwaa Owusu; Kannry, Joseph L.; Hripcsak, George; Bottinger, Erwin P.; Gottesman, Omri

    2014-01-01

    This study assessed physician attitudes toward adopting genome-guided prescribing through clinical decision support (CDS), prior to enlisting in the Clinical Implementation of Personalized Medicine through Electronic Health Records and Genomics pilot pharmacogenomics project (CLIPMERGE PGx). We developed a survey instrument that includes the Evidence Based Practice Attitude Scale, adapted to measure attitudes toward adopting genome-informed interventions (EBPAS-GII). The survey also includes items to measure physicians’ characteristics (awareness, experience, and perceived usefulness), attitudes about personal genome testing (PGT) services, and comfort using technology. We surveyed 101 General Internal Medicine physicians from the Icahn School of Medicine at Mount Sinai (ISMMS). The majority were residency program trainees (~88%). Prior to enlisting into CLIPMERGE PGx, most physicians were aware of and had used decision support aids. Few physicians, however, were aware of and had used genome-guided prescribing. The majority of physicians viewed decision support aids and genotype data as being useful for making prescribing decisions. Most physicians had not heard of, but were willing to use, PGT services and felt comfortable interpreting PGT results. Most physicians were comfortable with technology. Physicians who perceived genotype data to be useful in making prescribing decisions, had more positive attitudes toward adopting genome-guided prescribing through CDS. Our findings suggest that internal medicine physicians have a deficit in their familiarity and comfort interpreting and using genomic information. This has reinforced the importance of gathering feedback and guidance from our enrolled physicians when designing genome-guided CDS and the importance of prioritizing genomic medicine education at our institutions. PMID:25562141

  20. The next chapter in patient blood management: real-time clinical decision support.

    PubMed

    Goodnough, Lawrence Tim; Shah, Neil

    2014-12-01

    Blood transfusion was identified by the American Medical Association as one of the top five most frequently overused therapies. Utilization review has been required by accreditation agencies, but retrospective review has been ineffective due to labor-intense resources applied to only a sampling of transfusion events. Electronic medical records have allowed clinical decision support (CDS) to occur via a best practices alert at the critical decision point concurrently with physician order entry. We review emerging strategies for improving blood utilization. Implementation of CDS at our institution decreased the percentage of transfusions in patients with a hemoglobin level of more than 8 g/dL from 60% to less than 30%. Annual RBC transfusions were reduced by 24%, despite concurrent increases in patient discharge volumes and case mix complexity. This resulted in acquisition costs savings (direct blood product purchase costs) of $6.4 million over 4 years. We have been able to significantly reduce inappropriate blood transfusions and related costs through an educational initiative coupled with real-time CDS. In deriving increased value out of health care, CDS can be applied to a number of overuse measures in laboratory testing, radiology, and therapy such as antibiotics, as outlined by the American Board of Internal Medicine's Choosing Wisely campaign. Copyright© by the American Society for Clinical Pathology.

  1. A Clinical Decision Support Engine Based on a National Medication Repository for the Detection of Potential Duplicate Medications: Design and Evaluation.

    PubMed

    Yang, Cheng-Yi; Lo, Yu-Sheng; Chen, Ray-Jade; Liu, Chien-Tsai

    2018-01-19

    A computerized physician order entry (CPOE) system combined with a clinical decision support system can reduce duplication of medications and thus adverse drug reactions. However, without infrastructure that supports patients' integrated medication history across health care facilities nationwide, duplication of medication can still occur. In Taiwan, the National Health Insurance Administration has implemented a national medication repository and Web-based query system known as the PharmaCloud, which allows physicians to access their patients' medication records prescribed by different health care facilities across Taiwan. This study aimed to develop a scalable, flexible, and thematic design-based clinical decision support (CDS) engine, which integrates a national medication repository to support CPOE systems in the detection of potential duplication of medication across health care facilities, as well as to analyze its impact on clinical encounters. A CDS engine was developed that can download patients' up-to-date medication history from the PharmaCloud and support a CPOE system in the detection of potential duplicate medications. When prescribing a medication order using the CPOE system, a physician receives an alert if there is a potential duplicate medication. To investigate the impact of the CDS engine on clinical encounters in outpatient services, a clinical encounter log was created to collect information about time, prescribed drugs, and physicians' responses to handling the alerts for each encounter. The CDS engine was installed in a teaching affiliate hospital, and the clinical encounter log collected information for 3 months, during which a total of 178,300 prescriptions were prescribed in the outpatient departments. In all, 43,844/178,300 (24.59%) patients signed the PharmaCloud consent form allowing their physicians to access their medication history in the PharmaCloud. The rate of duplicate medication was 5.83% (1843/31,614) of prescriptions. When prescribing using the CDS engine, the median encounter time was 4.3 (IQR 2.3-7.3) min, longer than that without using the CDS engine (median 3.6, IQR 2.0-6.3 min). From the physicians' responses, we found that 42.06% (1908/4536) of the potential duplicate medications were recognized by the physicians and the medication orders were canceled. The CDS engine could easily extend functions for detection of adverse drug reactions when more and more electronic health record systems are adopted. Moreover, the CDS engine can retrieve more updated and completed medication histories in the PharmaCloud, so it can have better performance for detection of duplicate medications. Although our CDS engine approach could enhance medication safety, it would make for a longer encounter time. This problem can be mitigated by careful evaluation of adopted solutions for implementation of the CDS engine. The successful key component of a CDS engine is the completeness of the patient's medication history, thus further research to assess the factors in increasing the PharmaCloud consent rate is required. ©Cheng-Yi Yang, Yu-Sheng Lo, Ray-Jade Chen, Chien-Tsai Liu. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 19.01.2018.

  2. Usability evaluation of pharmacogenomics clinical decision support aids and clinical knowledge resources in a computerized provider order entry system: a mixed methods approach.

    PubMed

    Devine, Emily Beth; Lee, Chia-Ju; Overby, Casey L; Abernethy, Neil; McCune, Jeannine; Smith, Joe W; Tarczy-Hornoch, Peter

    2014-07-01

    Pharmacogenomics (PGx) is positioned to have a widespread impact on the practice of medicine, yet physician acceptance is low. The presentation of context-specific PGx information, in the form of clinical decision support (CDS) alerts embedded in a computerized provider order entry (CPOE) system, can aid uptake. Usability evaluations can inform optimal design, which, in turn, can spur adoption. The study objectives were to: (1) evaluate an early prototype, commercial CPOE system with PGx-CDS alerts in a simulated environment, (2) identify potential improvements to the system user interface, and (3) understand the contexts under which PGx knowledge embedded in an electronic health record is useful to prescribers. Using a mixed methods approach, we presented seven cardiologists and three oncologists with five hypothetical clinical case scenarios. Each scenario featured a drug for which a gene encoding drug metabolizing enzyme required consideration of dosage adjustment. We used Morae(®) to capture comments and on-screen movements as participants prescribed each drug. In addition to PGx-CDS alerts, 'Infobutton(®)' and 'Evidence' icons provided participants with clinical knowledge resources to aid decision-making. Nine themes emerged. Five suggested minor improvements to the CPOE user interface; two suggested presenting PGx information through PGx-CDS alerts using an 'Infobutton' or 'Evidence' icon. The remaining themes were strong recommendations to provide succinct, relevant guidelines and dosing recommendations of phenotypic information from credible and trustworthy sources; any more information was overwhelming. Participants' median rating of PGx-CDS system usability was 2 on a Likert scale ranging from 1 (strongly agree) to 7 (strongly disagree). Usability evaluation results suggest that participants considered PGx information important for improving prescribing decisions; and that they would incorporate PGx-CDS when information is presented in relevant and useful ways. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Automated recommendation for cervical cancer screening and surveillance.

    PubMed

    Wagholikar, Kavishwar B; MacLaughlin, Kathy L; Casey, Petra M; Kastner, Thomas M; Henry, Michael R; Hankey, Ronald A; Peters, Steve G; Greenes, Robert A; Chute, Christopher G; Liu, Hongfang; Chaudhry, Rajeev

    2014-01-01

    Because of the complexity of cervical cancer prevention guidelines, clinicians often fail to follow best-practice recommendations. Moreover, existing clinical decision support (CDS) systems generally recommend a cervical cytology every three years for all female patients, which is inappropriate for patients with abnormal findings that require surveillance at shorter intervals. To address this problem, we developed a decision tree-based CDS system that integrates national guidelines to provide comprehensive guidance to clinicians. Validation was performed in several iterations by comparing recommendations generated by the system with those of clinicians for 333 patients. The CDS system extracted relevant patient information from the electronic health record and applied the guideline model with an overall accuracy of 87%. Providers without CDS assistance needed an average of 1 minute 39 seconds to decide on recommendations for management of abnormal findings. Overall, our work demonstrates the feasibility and potential utility of automated recommendation system for cervical cancer screening and surveillance.

  4. Recommended practices for computerized clinical decision support and knowledge management in community settings: a qualitative study

    PubMed Central

    2012-01-01

    Background The purpose of this study was to identify recommended practices for computerized clinical decision support (CDS) development and implementation and for knowledge management (KM) processes in ambulatory clinics and community hospitals using commercial or locally developed systems in the U.S. Methods Guided by the Multiple Perspectives Framework, the authors conducted ethnographic field studies at two community hospitals and five ambulatory clinic organizations across the U.S. Using a Rapid Assessment Process, a multidisciplinary research team: gathered preliminary assessment data; conducted on-site interviews, observations, and field surveys; analyzed data using both template and grounded methods; and developed universal themes. A panel of experts produced recommended practices. Results The team identified ten themes related to CDS and KM. These include: 1) workflow; 2) knowledge management; 3) data as a foundation for CDS; 4) user computer interaction; 5) measurement and metrics; 6) governance; 7) translation for collaboration; 8) the meaning of CDS; 9) roles of special, essential people; and 10) communication, training, and support. Experts developed recommendations about each theme. The original Multiple Perspectives framework was modified to make explicit a new theoretical construct, that of Translational Interaction. Conclusions These ten themes represent areas that need attention if a clinic or community hospital plans to implement and successfully utilize CDS. In addition, they have implications for workforce education, research, and national-level policy development. The Translational Interaction construct could guide future applied informatics research endeavors. PMID:22333210

  5. Workshop on using natural language processing applications for enhancing clinical decision making: an executive summary

    PubMed Central

    Pai, Vinay M; Rodgers, Mary; Conroy, Richard; Luo, James; Zhou, Ruixia; Seto, Belinda

    2014-01-01

    In April 2012, the National Institutes of Health organized a two-day workshop entitled ‘Natural Language Processing: State of the Art, Future Directions and Applications for Enhancing Clinical Decision-Making’ (NLP-CDS). This report is a summary of the discussions during the second day of the workshop. Collectively, the workshop presenters and participants emphasized the need for unstructured clinical notes to be included in the decision making workflow and the need for individualized longitudinal data tracking. The workshop also discussed the need to: (1) combine evidence-based literature and patient records with machine-learning and prediction models; (2) provide trusted and reproducible clinical advice; (3) prioritize evidence and test results; and (4) engage healthcare professionals, caregivers, and patients. The overall consensus of the NLP-CDS workshop was that there are promising opportunities for NLP and CDS to deliver cognitive support for healthcare professionals, caregivers, and patients. PMID:23921193

  6. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  7. Measuring Clinical Decision Support Influence on Evidence-Based Nursing Practice.

    PubMed

    Cortez, Susan; Dietrich, Mary S; Wells, Nancy

    2016-07-01

    To measure the effect of clinical decision support (CDS) on oncology nurse evidence-based practice (EBP).
. Longitudinal cluster-randomized design.
. Four distinctly separate oncology clinics associated with an academic medical center.
. The study sample was comprised of randomly selected data elements from the nursing documentation software. The data elements were patient-reported symptoms and the associated nurse interventions. The total sample observations were 600, derived from a baseline, posteducation, and postintervention sample of 200 each (100 in the intervention group and 100 in the control group for each sample).
. The cluster design was used to support randomization of the study intervention at the clinic level rather than the individual participant level to reduce possible diffusion of the study intervention. An elongated data collection cycle (11 weeks) controlled for temporary increases in nurse EBP related to the education or CDS intervention.
. The dependent variable was the nurse evidence-based documentation rate, calculated from the nurse-documented interventions. The independent variable was the CDS added to the nursing documentation software.
. The average EBP rate at baseline for the control and intervention groups was 27%. After education, the average EBP rate increased to 37%, and then decreased to 26% in the postintervention sample. Mixed-model linear statistical analysis revealed no significant interaction of group by sample. The CDS intervention did not result in an increase in nurse EBP.
. EBP education increased nurse EBP documentation rates significantly but only temporarily. Nurses may have used evidence in practice but may not have documented their interventions.
. More research is needed to understand the complex relationship between CDS, nursing practice, and nursing EBP intervention documentation. CDS may have a different effect on nurse EBP, physician EBP, and other medical professional EBP.

  8. Publication, discovery and interoperability of Clinical Decision Support Systems: A Linked Data approach.

    PubMed

    Marco-Ruiz, Luis; Pedrinaci, Carlos; Maldonado, J A; Panziera, Luca; Chen, Rong; Bellika, J Gustav

    2016-08-01

    The high costs involved in the development of Clinical Decision Support Systems (CDSS) make it necessary to share their functionality across different systems and organizations. Service Oriented Architectures (SOA) have been proposed to allow reusing CDSS by encapsulating them in a Web service. However, strong barriers in sharing CDS functionality are still present as a consequence of lack of expressiveness of services' interfaces. Linked Services are the evolution of the Semantic Web Services paradigm to process Linked Data. They aim to provide semantic descriptions over SOA implementations to overcome the limitations derived from the syntactic nature of Web services technologies. To facilitate the publication, discovery and interoperability of CDS services by evolving them into Linked Services that expose their interfaces as Linked Data. We developed methods and models to enhance CDS SOA as Linked Services that define a rich semantic layer based on machine interpretable ontologies that powers their interoperability and reuse. These ontologies provided unambiguous descriptions of CDS services properties to expose them to the Web of Data. We developed models compliant with Linked Data principles to create a semantic representation of the components that compose CDS services. To evaluate our approach we implemented a set of CDS Linked Services using a Web service definition ontology. The definitions of Web services were linked to the models developed in order to attach unambiguous semantics to the service components. All models were bound to SNOMED-CT and public ontologies (e.g. Dublin Core) in order to count on a lingua franca to explore them. Discovery and analysis of CDS services based on machine interpretable models was performed reasoning over the ontologies built. Linked Services can be used effectively to expose CDS services to the Web of Data by building on current CDS standards. This allows building shared Linked Knowledge Bases to provide machine interpretable semantics to the CDS service description alleviating the challenges on interoperability and reuse. Linked Services allow for building 'digital libraries' of distributed CDS services that can be hosted and maintained in different organizations. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. A Multidisciplinary Sepsis Program Enabled by a Two-Stage Clinical Decision Support System: Factors That Influence Patient Outcomes.

    PubMed

    Amland, Robert C; Haley, James M; Lyons, Jason J

    2016-11-01

    Sepsis is an inflammatory response triggered by infection, with risk of in-hospital mortality fueled by disease progression. Early recognition and intervention by multidisciplinary sepsis programs may reverse the inflammatory response among at-risk patient populations, potentially improving outcomes. This retrospective study of a sepsis program enabled by a 2-stage sepsis Clinical Decision Support (CDS) system sought to evaluate the program's impact, identify early indicators that may influence outcomes, and uncover opportunities for quality improvement. Data encompassed 16 527 adult hospitalizations from 2014 and 2015. Of 2108 non-intensive care unit patients screened-in by sepsis CDS, 97% patients were stratified by 177 providers. Risk of adverse outcome improved 30% from baseline to year end, with gains materializing and stabilizing at month 7 after sepsis program go-live. Early indicators likely to influence outcomes include patient age, recent hospitalization, electrolyte abnormalities, hypovolemic shock, hypoxemia, patient location when sepsis CDS activated, and specific alert patterns. © The Author(s) 2015.

  10. Clinical Decision Support for a Multicenter Trial of Pediatric Head Trauma

    PubMed Central

    Swietlik, Marguerite; Deakyne, Sara; Hoffman, Jeffrey M.; Grundmeier, Robert W.; Paterno, Marilyn D.; Rocha, Beatriz H.; Schaeffer, Molly H; Pabbathi, Deepika; Alessandrini, Evaline; Ballard, Dustin; Goldberg, Howard S.; Kuppermann, Nathan; Dayan, Peter S.

    2016-01-01

    Summary Introduction For children who present to emergency departments (EDs) due to blunt head trauma, ED clinicians must decide who requires computed tomography (CT) scanning to evaluate for traumatic brain injury (TBI). The Pediatric Emergency Care Applied Research Network (PECARN) derived and validated two age-based prediction rules to identify children at very low risk of clinically-important traumatic brain injuries (ciTBIs) who do not typically require CT scans. In this case report, we describe the strategy used to implement the PECARN TBI prediction rules via electronic health record (EHR) clinical decision support (CDS) as the intervention in a multicenter clinical trial. Methods Thirteen EDs participated in this trial. The 10 sites receiving the CDS intervention used the Epic® EHR. All sites implementing EHR-based CDS built the rules by using the vendor’s CDS engine. Based on a sociotechnical analysis, we designed the CDS so that recommendations could be displayed immediately after any provider entered prediction rule data. One central site developed and tested the intervention package to be exported to other sites. The intervention package included a clinical trial alert, an electronic data collection form, the CDS rules and the format for recommendations. Results The original PECARN head trauma prediction rules were derived from physician documentation while this pragmatic trial led each site to customize their workflows and allow multiple different providers to complete the head trauma assessments. These differences in workflows led to varying completion rates across sites as well as differences in the types of providers completing the electronic data form. Site variation in internal change management processes made it challenging to maintain the same rigor across all sites. This led to downstream effects when data reports were developed. Conclusions The process of a centralized build and export of a CDS system in one commercial EHR system successfully supported a multicenter clinical trial. PMID:27437059

  11. Working at the intersection of context, culture, and technology: Provider perspectives on antimicrobial stewardship in the emergency department using electronic health record clinical decision support.

    PubMed

    Chung, Phillip; Scandlyn, Jean; Dayan, Peter S; Mistry, Rakesh D

    2017-11-01

    Antibiotic stewardship programs (ASPs) have not been fully developed for the emergency department (ED), in part the result of the barriers characteristic of this setting. Electronic health record-based clinical decision support (EHR CDS) represents a promising strategy to implement ASPs in the ED. We aimed to determine the cultural beliefs and structural barriers and facilitators to implementation of antimicrobial stewardship in the pediatric ED using EHR CDS. Interviews and focus groups were conducted with hospital and ED leadership, attending ED physicians, nurse practitioners, physician assistants, and residents at a single health system in Colorado. We reviewed and coded the data using constant comparative analysis and framework analysis until a final set of themes emerged. Two dominant perceptions shaped providers' perspectives on ASPs in the ED and EHR CDS: (1) maintaining workflow efficiency and (2) constrained decision-making autonomy. Clinicians identified structural barriers to ASPs, such as pace of the ED, and various beliefs that shaped patterns of practice, including accommodating the prescribing decisions of other providers and managing parental expectations. Recommendations to enhance uptake focused on designing a simple yet flexible user interface, providing clinicians with performance data, and on-boarding clinicians to enhance buy-in. Developing a successful ED-based ASP using EHR CDS should attend to technologic needs, the institutional context, and the cultural beliefs of practice associated with providers' antibiotic prescribing. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Improving Emergency Department Triage Classification with Computerized Clinical Decision Support at a Pediatric Hospital

    ERIC Educational Resources Information Center

    Kunisch, Joseph Martin

    2012-01-01

    Background: The Emergency Severity Index (ESI) is an emergency department (ED) triage classification system based on estimated patient-specific resource utilization. Rules for a computerized clinical decision support (CDS) system based on a patient's chief complaint were developed and tested using a stochastic model for predicting ESI scores.…

  13. Recommendations for Selecting Drug-Drug Interactions for Clinical Decision Support

    PubMed Central

    Tilson, Hugh; Hines, Lisa E.; McEvoy, Gerald; Weinstein, David M.; Hansten, Philip D.; Matuszewski, Karl; le Comte, Marianne; Higby-Baker, Stefanie; Hanlon, Joseph T.; Pezzullo, Lynn; Vieson, Kathleen; Helwig, Amy L.; Huang, Shiew-Mei; Perre, Anthony; Bates, David W.; Poikonen, John; Wittie, Michael A.; Grizzle, Amy J.; Brown, Mary; Malone, Daniel C.

    2016-01-01

    Purpose To recommend principles for including drug-drug interactions (DDIs) in clinical decision support. Methods A conference series was conducted to improve clinical decision support (CDS) for DDIs. The Content Workgroup met monthly by webinar from January 2013 to February 2014, with two in-person meetings to reach consensus. The workgroup consisted of 20 experts in pharmacology, drug information, and CDS from academia, government agencies, health information (IT) vendors, and healthcare organizations. Workgroup members addressed four key questions: (1) What process should be used to develop and maintain a standard set of DDIs?; (2) What information should be included in a knowledgebase of standard DDIs?; (3) Can/should a list of contraindicated drug pairs be established?; and (4) How can DDI alerts be more intelligently filtered? Results To develop and maintain a standard set of DDIs for CDS in the United States, we recommend a transparent, systematic, and evidence-driven process with graded recommendations by a consensus panel of experts and oversight by a national organization. We outline key DDI information needed to help guide clinician decision-making. We recommend judicious classification of DDIs as contraindicated, as only a small set of drug combinations are truly contraindicated. Finally, we recommend more research to identify methods to safely reduce repetitive and less relevant alerts. Conclusion A systematic ongoing process is necessary to select DDIs for alerting clinicians. We anticipate that our recommendations can lead to consistent and clinically relevant content for interruptive DDIs, and thus reduce alert fatigue and improve patient safety. PMID:27045070

  14. The Morningside Initiative: Collaborative Development of a Knowledge Repository to Accelerate Adoption of Clinical Decision Support

    PubMed Central

    Greenes, Robert; Bloomrosen, Meryl; Brown-Connolly, Nancy E.; Curtis, Clayton; Detmer, Don E; Enberg, Robert; Fridsma, Douglas; Fry, Emory; Goldstein, Mary K; Haug, Peter; Hulse, Nathan; Hongsermeier, Tonya; Maviglia, Saverio; Robbins, Craig W; Shah, Hemant

    2010-01-01

    The Morningside Initiative is a public-private activity that has evolved from an August, 2007, meeting at the Morningside Inn, in Frederick, MD, sponsored by the Telemedicine and Advanced Technology Research Center (TATRC) of the US Army Medical Research Materiel Command. Participants were subject matter experts in clinical decision support (CDS) and included representatives from the Department of Defense, Veterans Health Administration, Kaiser Permanente, Partners Healthcare System, Henry Ford Health System, Arizona State University, and the American Medical Informatics Association (AMIA). The Morningside Initiative was convened in response to the AMIA Roadmap for National Action on Clinical Decision Support and on the basis of other considerations and experiences of the participants. Its formation was the unanimous recommendation of participants at the 2007 meeting which called for creating a shared repository of executable knowledge for diverse health care organizations and practices, as well as health care system vendors. The rationale is based on the recognition that sharing of clinical knowledge needed for CDS across organizations is currently virtually non-existent, and that, given the considerable investment needed for creating, maintaining and updating authoritative knowledge, which only larger organizations have been able to undertake, this is an impediment to widespread adoption and use of CDS. The Morningside Initiative intends to develop and refine (1) an organizational framework, (2) a technical approach, and (3) CDS content acquisition and management processes for sharing CDS knowledge content, tools, and experience that will scale with growing numbers of participants and can be expanded in scope of content and capabilities. Intermountain Healthcare joined the initial set of participants shortly after its formation. The efforts of the Morningside Initiative are intended to serve as the basis for a series of next steps in a national agenda for CDS. It is based on the belief that sharing of knowledge can be highly effective as is the case in other competitive domains such as genomics. Participants in the Morningside Initiative believe that a coordinated effort between the private and public sectors is needed to accomplish this goal and that a small number of highly visible and respected health care organizations in the public and private sector can lead by example. Ultimately, a future collaborative knowledge sharing organization must have a sustainable long-term business model for financial support. PMID:21603282

  15. The morningside initiative: collaborative development of a knowledge repository to accelerate adoption of clinical decision support.

    PubMed

    Greenes, Robert; Bloomrosen, Meryl; Brown-Connolly, Nancy E; Curtis, Clayton; Detmer, Don E; Enberg, Robert; Fridsma, Douglas; Fry, Emory; Goldstein, Mary K; Haug, Peter; Hulse, Nathan; Hongsermeier, Tonya; Maviglia, Saverio; Robbins, Craig W; Shah, Hemant

    2010-01-01

    The Morningside Initiative is a public-private activity that has evolved from an August, 2007, meeting at the Morningside Inn, in Frederick, MD, sponsored by the Telemedicine and Advanced Technology Research Center (TATRC) of the US Army Medical Research Materiel Command. Participants were subject matter experts in clinical decision support (CDS) and included representatives from the Department of Defense, Veterans Health Administration, Kaiser Permanente, Partners Healthcare System, Henry Ford Health System, Arizona State University, and the American Medical Informatics Association (AMIA). The Morningside Initiative was convened in response to the AMIA Roadmap for National Action on Clinical Decision Support and on the basis of other considerations and experiences of the participants. Its formation was the unanimous recommendation of participants at the 2007 meeting which called for creating a shared repository of executable knowledge for diverse health care organizations and practices, as well as health care system vendors. The rationale is based on the recognition that sharing of clinical knowledge needed for CDS across organizations is currently virtually non-existent, and that, given the considerable investment needed for creating, maintaining and updating authoritative knowledge, which only larger organizations have been able to undertake, this is an impediment to widespread adoption and use of CDS. The Morningside Initiative intends to develop and refine (1) an organizational framework, (2) a technical approach, and (3) CDS content acquisition and management processes for sharing CDS knowledge content, tools, and experience that will scale with growing numbers of participants and can be expanded in scope of content and capabilities. Intermountain Healthcare joined the initial set of participants shortly after its formation. The efforts of the Morningside Initiative are intended to serve as the basis for a series of next steps in a national agenda for CDS. It is based on the belief that sharing of knowledge can be highly effective as is the case in other competitive domains such as genomics. Participants in the Morningside Initiative believe that a coordinated effort between the private and public sectors is needed to accomplish this goal and that a small number of highly visible and respected health care organizations in the public and private sector can lead by example. Ultimately, a future collaborative knowledge sharing organization must have a sustainable long-term business model for financial support.

  16. Recommendations for selecting drug-drug interactions for clinical decision support.

    PubMed

    Tilson, Hugh; Hines, Lisa E; McEvoy, Gerald; Weinstein, David M; Hansten, Philip D; Matuszewski, Karl; le Comte, Marianne; Higby-Baker, Stefanie; Hanlon, Joseph T; Pezzullo, Lynn; Vieson, Kathleen; Helwig, Amy L; Huang, Shiew-Mei; Perre, Anthony; Bates, David W; Poikonen, John; Wittie, Michael A; Grizzle, Amy J; Brown, Mary; Malone, Daniel C

    2016-04-15

    Recommendations for including drug-drug interactions (DDIs) in clinical decision support (CDS) are presented. A conference series was conducted to improve CDS for DDIs. A work group consisting of 20 experts in pharmacology, drug information, and CDS from academia, government agencies, health information vendors, and healthcare organizations was convened to address (1) the process to use for developing and maintaining a standard set of DDIs, (2) the information that should be included in a knowledge base of standard DDIs, (3) whether a list of contraindicated drug pairs can or should be established, and (4) how to more intelligently filter DDI alerts. We recommend a transparent, systematic, and evidence-driven process with graded recommendations by a consensus panel of experts and oversight by a national organization. We outline key DDI information needed to help guide clinician decision-making. We recommend judicious classification of DDIs as contraindicated and more research to identify methods to safely reduce repetitive and less-relevant alerts. An expert panel with a centralized organizer or convener should be established to develop and maintain a standard set of DDIs for CDS in the United States. The process should be evidence driven, transparent, and systematic, with feedback from multiple stakeholders for continuous improvement. The scope of the expert panel's work should be carefully managed to ensure that the process is sustainable. Support for research to improve DDI alerting in the future is also needed. Adoption of these steps may lead to consistent and clinically relevant content for interruptive DDIs, thus reducing alert fatigue and improving patient safety. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  17. Using Arden Syntax for the creation of a multi-patient surveillance dashboard.

    PubMed

    Kraus, Stefan; Drescher, Caroline; Sedlmayr, Martin; Castellanos, Ixchel; Prokosch, Hans-Ulrich; Toddenroth, Dennis

    2015-10-09

    Most practically deployed Arden-Syntax-based clinical decision support (CDS) modules process data from individual patients. The specification of Arden Syntax, however, would in principle also support multi-patient CDS. The patient data management system (PDMS) at our local intensive care units does not natively support patient overviews from customizable CDS routines, but local physicians indicated a demand for multi-patient tabular overviews of important clinical parameters such as key laboratory measurements. As our PDMS installation provides Arden Syntax support, we set out to explore the capability of Arden Syntax for multi-patient CDS by implementing a prototypical dashboard for visualizing laboratory findings from patient sets. Our implementation leveraged the object data type, supported by later versions of Arden, which turned out to be serviceable for representing complex input data from several patients. For our prototype, we designed a modularized architecture that separates the definition of technical operations, in particular the control of the patient context, from the actual clinical knowledge. Individual Medical Logic Modules (MLMs) for processing single patient attributes could then be developed according to well-tried Arden Syntax conventions. We successfully implemented a working dashboard prototype entirely in Arden Syntax. The architecture consists of a controller MLM to handle the patient context, a presenter MLM to generate a dashboard view, and a set of traditional MLMs containing the clinical decision logic. Our prototype could be integrated into the graphical user interface of the local PDMS. We observed that with realistic input data the average execution time of about 200ms for generating dashboard views attained applicable performance. Our study demonstrated the general feasibility of creating multi-patient CDS routines in Arden Syntax. We believe that our prototypical dashboard also suggests that such implementations can be relatively easy, and may simultaneously hold promise for sharing dashboards between institutions and reusing elementary components for additional dashboards. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Back to the Bedside: Developing a Bedside Aid for Concussion and Brain Injury Decisions in the Emergency Department

    PubMed Central

    Melnick, Edward R.; Lopez, Kevin; Hess, Erik P.; Abujarad, Fuad; Brandt, Cynthia A.; Shiffman, Richard N.; Post, Lori A.

    2015-01-01

    Context: Current information-rich electronic health record (EHR) interfaces require large, high-resolution screens running on desktop computers. This interface compromises the provider’s already limited time at the bedside by physically separating the patient from the doctor. The case study presented here describes a patient-centered clinical decision support (CDS) design process that aims to bring the physician back to the bedside by integrating a patient decision aid with CDS for shared use by the patient and provider on a touchscreen tablet computer for deciding whether or not to obtain a CT scan for minor head injury in the emergency department, a clinical scenario that could benefit from CDS but has failed previous implementation attempts. Case Description: This case study follows the user-centered design (UCD) approach to build a bedside aid that is useful and usable, and that promotes shared decision-making between patients and their providers using a tablet computer at the bedside. The patient-centered decision support design process focuses on the prototype build using agile software development, but also describes the following: (1) the requirement gathering phase including triangulated qualitative research (focus groups and cognitive task analysis) to understand current challenges, (2) features for patient education, the physician, and shared decision-making, (3) system architecture and technical requirements, and (4) future plans for formative usability testing and field testing. Lessons Learned: We share specific lessons learned and general recommendations from critical insights gained in the patient-centered decision support design process about early stakeholder engagement, EHR integration, external expert feedback, challenges to two users on a single device, project management, and accessibility. Conclusions: Successful implementation of this tool will require seamless integration into the provider’s workflow. This protocol can create an effective interface for shared decision-making and safe resource reduction at the bedside in the austere and dynamic clinical environment of the ED and is generalizable for these purposes in other clinical environments as well. PMID:26290885

  19. Back to the Bedside: Developing a Bedside Aid for Concussion and Brain Injury Decisions in the Emergency Department.

    PubMed

    Melnick, Edward R; Lopez, Kevin; Hess, Erik P; Abujarad, Fuad; Brandt, Cynthia A; Shiffman, Richard N; Post, Lori A

    2015-01-01

    Current information-rich electronic health record (EHR) interfaces require large, high-resolution screens running on desktop computers. This interface compromises the provider's already limited time at the bedside by physically separating the patient from the doctor. The case study presented here describes a patient-centered clinical decision support (CDS) design process that aims to bring the physician back to the bedside by integrating a patient decision aid with CDS for shared use by the patient and provider on a touchscreen tablet computer for deciding whether or not to obtain a CT scan for minor head injury in the emergency department, a clinical scenario that could benefit from CDS but has failed previous implementation attempts. This case study follows the user-centered design (UCD) approach to build a bedside aid that is useful and usable, and that promotes shared decision-making between patients and their providers using a tablet computer at the bedside. The patient-centered decision support design process focuses on the prototype build using agile software development, but also describes the following: (1) the requirement gathering phase including triangulated qualitative research (focus groups and cognitive task analysis) to understand current challenges, (2) features for patient education, the physician, and shared decision-making, (3) system architecture and technical requirements, and (4) future plans for formative usability testing and field testing. We share specific lessons learned and general recommendations from critical insights gained in the patient-centered decision support design process about early stakeholder engagement, EHR integration, external expert feedback, challenges to two users on a single device, project management, and accessibility. Successful implementation of this tool will require seamless integration into the provider's workflow. This protocol can create an effective interface for shared decision-making and safe resource reduction at the bedside in the austere and dynamic clinical environment of the ED and is generalizable for these purposes in other clinical environments as well.

  20. Incorporating INTERACT II Clinical Decision Support Tools into Nursing Home Health Information Technology

    PubMed Central

    Handler, Steven M.; Sharkey, Siobhan S.; Hudak, Sandra; Ouslander, Joseph G.

    2012-01-01

    A substantial reduction in hospitalization rates has been associated with the implementation of the Interventions to Reduce Acute Care Transfers (INTERACT) quality improvement intervention using the accompanying paper-based clinical practice tools (INTERACT II). There is significant potential to further increase the impact of INTERACT by integrating INTERACT II tools into nursing home (NH) health information technology (HIT) via standalone or integrated clinical decision support (CDS) systems. This article highlights the process of translating INTERACT II tools from paper to NH HIT. The authors believe that widespread dissemination and integration of INTERACT II CDS tools into various NH HIT products could lead to sustainable improvement in resident and clinician process and outcome measures, including enhanced interclinician communication and a reduction in potentially avoidable hospitalizations. PMID:22267955

  1. Transforming user needs into functional requirements for an antibiotic clinical decision support system: explicating content analysis for system design.

    PubMed

    Bright, T J

    2013-01-01

    Many informatics studies use content analysis to generate functional requirements for system development. Explication of this translational process from qualitative data to functional requirements can strengthen the understanding and scientific rigor when applying content analysis in informatics studies. To describe a user-centered approach transforming emergent themes derived from focus group data into functional requirements for informatics solutions and to illustrate these methods to the development of an antibiotic clinical decision support system (CDS). THE APPROACH CONSISTED OF FIVE STEPS: 1) identify unmet therapeutic planning information needs via Focus Group Study-I, 2) develop a coding framework of therapeutic planning themes to refine the domain scope to antibiotic therapeutic planning, 3) identify functional requirements of an antibiotic CDS system via Focus Group Study-II, 4) discover informatics solutions and functional requirements from coded data, and 5) determine the types of information needed to support the antibiotic CDS system and link with the identified informatics solutions and functional requirements. The coding framework for Focus Group Study-I revealed unmet therapeutic planning needs. Twelve subthemes emerged and were clustered into four themes; analysis indicated a need for an antibiotic CDS intervention. Focus Group Study-II included five types of information needs. Comments from the Barrier/Challenge to information access and Function/Feature themes produced three informatics solutions and 13 functional requirements of an antibiotic CDS system. Comments from the Patient, Institution, and Domain themes generated required data elements for each informatics solution. This study presents one example explicating content analysis of focus group data and the analysis process to functional requirements from narrative data. Illustration of this 5-step method was used to develop an antibiotic CDS system, resolving unmet antibiotic prescribing needs. As a reusable approach, these techniques can be refined and applied to resolve unmet information needs with informatics interventions in additional domains.

  2. Transforming User Needs into Functional Requirements for an Antibiotic Clinical Decision Support System

    PubMed Central

    Bright, T.J.

    2013-01-01

    Summary Background Many informatics studies use content analysis to generate functional requirements for system development. Explication of this translational process from qualitative data to functional requirements can strengthen the understanding and scientific rigor when applying content analysis in informatics studies. Objective To describe a user-centered approach transforming emergent themes derived from focus group data into functional requirements for informatics solutions and to illustrate these methods to the development of an antibiotic clinical decision support system (CDS). Methods The approach consisted of five steps: 1) identify unmet therapeutic planning information needs via Focus Group Study-I, 2) develop a coding framework of therapeutic planning themes to refine the domain scope to antibiotic therapeutic planning, 3) identify functional requirements of an antibiotic CDS system via Focus Group Study-II, 4) discover informatics solutions and functional requirements from coded data, and 5) determine the types of information needed to support the antibiotic CDS system and link with the identified informatics solutions and functional requirements. Results The coding framework for Focus Group Study-I revealed unmet therapeutic planning needs. Twelve subthemes emerged and were clustered into four themes; analysis indicated a need for an antibiotic CDS intervention. Focus Group Study-II included five types of information needs. Comments from the Barrier/Challenge to information access and Function/Feature themes produced three informatics solutions and 13 functional requirements of an antibiotic CDS system. Comments from the Patient, Institution, and Domain themes generated required data elements for each informatics solution. Conclusion This study presents one example explicating content analysis of focus group data and the analysis process to functional requirements from narrative data. Illustration of this 5-step method was used to develop an antibiotic CDS system, resolving unmet antibiotic prescribing needs. As a reusable approach, these techniques can be refined and applied to resolve unmet information needs with informatics interventions in additional domains. PMID:24454586

  3. Participatory design of probability-based decision support tools for in-hospital nurses.

    PubMed

    Jeffery, Alvin D; Novak, Laurie L; Kennedy, Betsy; Dietrich, Mary S; Mion, Lorraine C

    2017-11-01

    To describe nurses' preferences for the design of a probability-based clinical decision support (PB-CDS) tool for in-hospital clinical deterioration. A convenience sample of bedside nurses, charge nurses, and rapid response nurses (n = 20) from adult and pediatric hospitals completed participatory design sessions with researchers in a simulation laboratory to elicit preferred design considerations for a PB-CDS tool. Following theme-based content analysis, we shared findings with user interface designers and created a low-fidelity prototype. Three major themes and several considerations for design elements of a PB-CDS tool surfaced from end users. Themes focused on "painting a picture" of the patient condition over time, promoting empowerment, and aligning probability information with what a nurse already believes about the patient. The most notable design element consideration included visualizing a temporal trend of the predicted probability of the outcome along with user-selected overlapping depictions of vital signs, laboratory values, and outcome-related treatments and interventions. Participants expressed that the prototype adequately operationalized requests from the design sessions. Participatory design served as a valuable method in taking the first step toward developing PB-CDS tools for nurses. This information about preferred design elements of tools that support, rather than interrupt, nurses' cognitive workflows can benefit future studies in this field as well as nurses' practice. Published by Oxford University Press on behalf of the American Medical Informatics Association 2017. This work is written by US Government employees and is in the public domain in the United States.

  4. Service oriented architecture for clinical decision support: a systematic review and future directions.

    PubMed

    Loya, Salvador Rodriguez; Kawamoto, Kensaku; Chatwin, Chris; Huser, Vojtech

    2014-12-01

    The use of a service-oriented architecture (SOA) has been identified as a promising approach for improving health care by facilitating reliable clinical decision support (CDS). A review of the literature through October 2013 identified 44 articles on this topic. The review suggests that SOA related technologies such as Business Process Model and Notation (BPMN) and Service Component Architecture (SCA) have not been generally adopted to impact health IT systems' performance for better care solutions. Additionally, technologies such as Enterprise Service Bus (ESB) and architectural approaches like Service Choreography have not been generally exploited among researchers and developers. Based on the experience of other industries and our observation of the evolution of SOA, we found that the greater use of these approaches have the potential to significantly impact SOA implementations for CDS.

  5. Service Oriented Architecture for Clinical Decision Support: A Systematic Review and Future Directions

    PubMed Central

    Loya, Salvador Rodriguez; Kawamoto, Kensaku; Chatwin, Chris; Huser, Vojtech

    2017-01-01

    The use of a service-oriented architecture (SOA) has been identified as a promising approach for improving health care by facilitating reliable clinical decision support (CDS). A review of the literature through October 2013 identified 44 articles on this topic. The review suggests that SOA related technologies such as Business Process Model and Notation (BPMN) and Service Component Architecture (SCA) have not been generally adopted to impact health IT systems’ performance for better care solutions. Additionally, technologies such as Enterprise Service Bus (ESB) and architectural approaches like Service Choreography have not been generally exploited among researchers and developers. Based on the experience of other industries and our observation of the evolution of SOA, we found that the greater use of these approaches have the potential to significantly impact SOA implementations for CDS PMID:25325996

  6. Using statistical anomaly detection models to find clinical decision support malfunctions.

    PubMed

    Ray, Soumi; McEvoy, Dustin S; Aaron, Skye; Hickman, Thu-Trang; Wright, Adam

    2018-05-11

    Malfunctions in Clinical Decision Support (CDS) systems occur due to a multitude of reasons, and often go unnoticed, leading to potentially poor outcomes. Our goal was to identify malfunctions within CDS systems. We evaluated 6 anomaly detection models: (1) Poisson Changepoint Model, (2) Autoregressive Integrated Moving Average (ARIMA) Model, (3) Hierarchical Divisive Changepoint (HDC) Model, (4) Bayesian Changepoint Model, (5) Seasonal Hybrid Extreme Studentized Deviate (SHESD) Model, and (6) E-Divisive with Median (EDM) Model and characterized their ability to find known anomalies. We analyzed 4 CDS alerts with known malfunctions from the Longitudinal Medical Record (LMR) and Epic® (Epic Systems Corporation, Madison, WI, USA) at Brigham and Women's Hospital, Boston, MA. The 4 rules recommend lead testing in children, aspirin therapy in patients with coronary artery disease, pneumococcal vaccination in immunocompromised adults and thyroid testing in patients taking amiodarone. Poisson changepoint, ARIMA, HDC, Bayesian changepoint and the SHESD model were able to detect anomalies in an alert for lead screening in children and in an alert for pneumococcal conjugate vaccine in immunocompromised adults. EDM was able to detect anomalies in an alert for monitoring thyroid function in patients on amiodarone. Malfunctions/anomalies occur frequently in CDS alert systems. It is important to be able to detect such anomalies promptly. Anomaly detection models are useful tools to aid such detections.

  7. Emergency physicians' knowledge and attitudes of clinical decision support in the electronic health record: a survey-based study.

    PubMed

    Ballard, Dustin W; Rauchwerger, Adina S; Reed, Mary E; Vinson, David R; Mark, Dustin G; Offerman, Steven R; Chettipally, Uli K; Graetz, Ilana; Dayan, Peter; Kuppermann, Nathan

    2013-04-01

    The objective was to investigate clinician knowledge of and attitudes toward clinical decision support (CDS) and its incorporation into the electronic health record (EHR). This was an electronic survey of emergency physicians (EPs) within an integrated health care delivery system that uses a complete EHR. Randomly assigned respondents completed one of two questionnaires, both including a hypothetical vignette and self-reported knowledge of and attitudes about CDS. One vignette version included CDS, and the other did not (NCDS). The vignette described a scenario in which a cranial computed tomography (CCT) is not recommended by validated prediction rules (the Pediatric Emergency Care Applied Research Network [PECARN] rules). In both survey versions, subjects responded first with their likely approach to evaluation and then again after receiving either CDS (the PECARN prediction rules) or no additional support. Descriptive statistics were used for self-reported responses and multivariate logistic regression was used to identify predictors of self-reported knowledge and use of the PECARN rules, as well as use of vignette responses. There were 339 respondents (68% response rate), with 172 of 339 (51%) randomized to the CDS version. Initially, 25% of respondents to each version indicated they would order CCTs. After CDS, 30 of 43 (70%) of respondents who initially would order CCTs changed their management decisions to no CCT versus two of 41 (5%) with the NCDS version (chi-square, p = 0.003). In response to self-report questions, 81 of 338 respondents (24%) reported having never heard of the PECARN prediction rules, 122 of 338 (36%) were aware of the rules but not their specifics, and 135 of 338 (40%) reported knowing the rules and their specifics. Respondents agreed with favorable statements about CDS (75% to 96% agreement across seven statements) and approaches to its implementation into the EHR (60% to 93% agreement across seven statements). In multivariable analyses, EPs with tenure of 5 to 14 years (odds ratio [AOR] = 0.51, 95% confidence interval [CI] = 0.30 to 0.86) and for 15 years or more (AOR = 0.37, 95% CI = 0.20 to 0.70) were significantly less likely to report knowing the specifics of the PECARN prediction rules compared with EPs who practiced for fewer than 5 years. In addition, in the initial vignette responses (across both versions), physicians with ≥15 years of ED tenure compared to those with fewer than 5 years of experience (AOR = 0.30, 95% CI = 0.13 to 0.69), and those reporting knowing the specifics of the PECARN prediction rules were less likely to order CCTs (AOR = 0.53, 95% CI = 0.30 to 0.92). EPs incorporated pediatric head trauma CDS via the EHR into their clinical judgment in a hypothetical scenario and reported favorable opinions of CDS in general and their inclusion into the EHR. © 2013 by the Society for Academic Emergency Medicine.

  8. Using Best Practices to Extract, Organize, and Reuse Embedded Decision Support Content Knowledge Rules from Mature Clinical Systems.

    PubMed

    DesAutels, Spencer J; Fox, Zachary E; Giuse, Dario A; Williams, Annette M; Kou, Qing-Hua; Weitkamp, Asli; Neal R, Patel; Bettinsoli Giuse, Nunzia

    2016-01-01

    Clinical decision support (CDS) knowledge, embedded over time in mature medical systems, presents an interesting and complex opportunity for information organization, maintenance, and reuse. To have a holistic view of all decision support requires an in-depth understanding of each clinical system as well as expert knowledge of the latest evidence. This approach to clinical decision support presents an opportunity to unify and externalize the knowledge within rules-based decision support. Driven by an institutional need to prioritize decision support content for migration to new clinical systems, the Center for Knowledge Management and Health Information Technology teams applied their unique expertise to extract content from individual systems, organize it through a single extensible schema, and present it for discovery and reuse through a newly created Clinical Support Knowledge Acquisition and Archival Tool (CS-KAAT). CS-KAAT can build and maintain the underlying knowledge infrastructure needed by clinical systems.

  9. Studying the Vendor Perspective on Clinical Decision Support

    PubMed Central

    Ash, Joan S.; Sittig, Dean F.; McMullen, Carmit K.; McCormack, James L.; Wright, Adam; Bunce, Arwen; Wasserman, Joseph; Mohan, Vishnu; Cohen, Deborah J.; Shapiro, Michael; Middleton, Blackford

    2011-01-01

    In prior work, using a Rapid Assessment Process (RAP), we have investigated clinical decision support (CDS) in ambulatory clinics and hospitals. We realized that individuals in these settings provide only one perspective related to the CDS landscape, which also includes content vendors and electronic health record (EHR) vendors. To discover content vendors’ perspectives and their perceived challenges, we modified RAP for industrial settings. We describe how we employed RAP, and show its utility by describing two illustrative themes. We found that while the content vendors believe they provide unique much-needed services, the amount of labor involved in content development is underestimated by others. We also found that the content vendors believe their products are resources to be used by practitioners, so they are somewhat protected from liability issues. To promote adequate understanding about these issues, we recommend a “three way conversation” among content vendors, EHR vendors, and user organizations. PMID:22195058

  10. Usability Testing of a Complex Clinical Decision Support Tool in the Emergency Department: Lessons Learned.

    PubMed

    Press, Anne; McCullagh, Lauren; Khan, Sundas; Schachter, Andy; Pardo, Salvatore; McGinn, Thomas

    2015-09-10

    As the electronic health record (EHR) becomes the preferred documentation tool across medical practices, health care organizations are pushing for clinical decision support systems (CDSS) to help bring clinical decision support (CDS) tools to the forefront of patient-physician interactions. A CDSS is integrated into the EHR and allows physicians to easily utilize CDS tools. However, often CDSS are integrated into the EHR without an initial phase of usability testing, resulting in poor adoption rates. Usability testing is important because it evaluates a CDSS by testing it on actual users. This paper outlines the usability phase of a study, which will test the impact of integration of the Wells CDSS for pulmonary embolism (PE) diagnosis into a large urban emergency department, where workflow is often chaotic and high stakes decisions are frequently made. We hypothesize that conducting usability testing prior to integration of the Wells score into an emergency room EHR will result in increased adoption rates by physicians. The objective of the study was to conduct usability testing for the integration of the Wells clinical prediction rule into a tertiary care center's emergency department EHR. We conducted usability testing of a CDS tool in the emergency department EHR. The CDS tool consisted of the Wells rule for PE in the form of a calculator and was triggered off computed tomography (CT) orders or patients' chief complaint. The study was conducted at a tertiary hospital in Queens, New York. There were seven residents that were recruited and participated in two phases of usability testing. The usability testing employed a "think aloud" method and "near-live" clinical simulation, where care providers interacted with standardized patients enacting a clinical scenario. Both phases were audiotaped, video-taped, and had screen-capture software activated for onscreen recordings. Phase I: Data from the "think-aloud" phase of the study showed an overall positive outlook on the Wells tool in assessing a patient for a PE diagnosis. Subjects described the tool as "well-organized" and "better than clinical judgment". Changes were made to improve tool placement into the EHR to make it optimal for decision-making, auto-populating boxes, and minimizing click fatigue. Phase II: After incorporating the changes noted in Phase 1, the participants noted tool improvements. There was less toggling between screens, they had all the clinical information required to complete the tool, and were able to complete the patient visit efficiently. However, an optimal location for triggering the tool remained controversial. This study successfully combined "think-aloud" protocol analysis with "near-live" clinical simulations in a usability evaluation of a CDS tool that will be implemented into the emergency room environment. Both methods proved useful in the assessment of the CDS tool and allowed us to refine tool usability and workflow.

  11. Standards for reporting randomized controlled trials in medical informatics: a systematic review of CONSORT adherence in RCTs on clinical decision support

    PubMed Central

    Berntsen, G; Lassen, K; Bellika, J G; Wootton, R; Lindsetmo, R O

    2011-01-01

    Introduction The Consolidated Standards for Reporting Trials (CONSORT) were published to standardize reporting and improve the quality of clinical trials. The objective of this study is to assess CONSORT adherence in randomized clinical trials (RCT) of disease specific clinical decision support (CDS). Methods A systematic search was conducted of the Medline, EMBASE, and Cochrane databases. RCTs on CDS were assessed against CONSORT guidelines and the Jadad score. Result 32 of 3784 papers identified in the primary search were included in the final review. 181 702 patients and 7315 physicians participated in the selected trials. Most trials were performed in primary care (22), including 897 general practitioner offices. RCTs assessing CDS for asthma (4), diabetes (4), and hyperlipidemia (3) were the most common. Thirteen CDS systems (40%) were implemented in electronic medical records, and 14 (43%) provided automatic alerts. CONSORT and Jadad scores were generally low; the mean CONSORT score was 30.75 (95% CI 27.0 to 34.5), median score 32, range 21–38. Fourteen trials (43%) did not clearly define the study objective, and 11 studies (34%) did not include a sample size calculation. Outcome measures were adequately identified and defined in 23 (71%) trials; adverse events or side effects were not reported in 20 trials (62%). Thirteen trials (40%) were of superior quality according to the Jadad score (≥3 points). Six trials (18%) reported on long-term implementation of CDS. Conclusion The overall quality of reporting RCTs was low. There is a need to develop standards for reporting RCTs in medical informatics. PMID:21803926

  12. Cross-vendor evaluation of key user-defined clinical decision support capabilities: a scenario-based assessment of certified electronic health records with guidelines for future development

    PubMed Central

    Wright, Adam; Sittig, Dean F

    2015-01-01

    Objective Clinical decision support (CDS) is essential for delivery of high-quality, cost-effective, and safe healthcare. The authors sought to evaluate the CDS capabilities across electronic health record (EHR) systems. Methods We evaluated the CDS implementation capabilities of 8 Office of the National Coordinator for Health Information Technology Authorized Certification Body (ONC-ACB)-certified EHRs. Within each EHR, the authors attempted to implement 3 user-defined rules that utilized the various data and logic elements expected of typical EHRs and that represented clinically important evidenced-based care. The rules were: 1) if a patient has amiodarone on his or her active medication list and does not have a thyroid-stimulating hormone (TSH) result recorded in the last 12 months, suggest ordering a TSH; 2) if a patient has a hemoglobin A1c result >7% and does not have diabetes on his or her problem list, suggest adding diabetes to the problem list; and 3) if a patient has coronary artery disease on his or her problem list and does not have aspirin on the active medication list, suggest ordering aspirin. Results Most evaluated EHRs lacked some CDS capabilities; 5 EHRs were able to implement all 3 rules, and the remaining 3 EHRs were unable to implement any of the rules. One of these did not allow users to customize CDS rules at all. The most frequently found shortcomings included the inability to use laboratory test results in rules, limit rules by time, use advanced Boolean logic, perform actions from the alert interface, and adequately test rules. Conclusion Significant improvements in the EHR certification and implementation procedures are necessary. PMID:26104739

  13. Collaboration, campaigns and champions for appropriate imaging: feedback from the Zagreb workshop.

    PubMed

    Remedios, D; Brkljacic, B; Ebdon-Jackson, S; Hierath, M; Sinitsyn, V; Vassileva, J

    2018-04-01

    Leading radiologists and representatives from national radiation protection regulatory authorities and health ministries from 19 countries of the European region worked together with five experts at the workshop on justification and appropriate use of imaging in Zagreb, Croatia, from 26 to 28 October 2017 jointly organised by the IAEA and the European Society of Radiology. The workshop served as a forum to exchange information on challenges and solutions for improving justification and the appropriate use of diagnostic imaging. Common barriers to improving the use of imaging referral guidelines were discussed and the need for increased collaboration identified. Examples of good practices were presented, including use of Clinical Decision Support (CDS) systems to facilitate rapid and good justification decisions. The workshop identified some of the needs of European countries for achieving more appropriate imaging proposing wider use of collaboration, campaigns and champions. • Drivers for appropriate imaging in Europe are similar to those elsewhere globally. • Implementing imaging referral guidelines is the main barrier to more appropriate imaging. • Clinical Decision Support systems (CDS) facilitates good referral practice and justification decisions. • Collaboration, campaigns and champions may improve awareness, appropriateness and audit.

  14. Advancing clinical decision support using lessons from outside of healthcare: an interdisciplinary systematic review.

    PubMed

    Wu, Helen W; Davis, Paul K; Bell, Douglas S

    2012-08-17

    Greater use of computerized decision support (DS) systems could address continuing safety and quality problems in healthcare, but the healthcare field has struggled to implement DS technology. This study surveys DS experience across multiple non-healthcare disciplines for new insights that are generalizable to healthcare provider decisions. In particular, it sought design principles and lessons learned from the other disciplines that could inform efforts to accelerate the adoption of clinical decision support (CDS). Our systematic review drew broadly from non-healthcare databases in the basic sciences, social sciences, humanities, engineering, business, and defense: PsychINFO, BusinessSource Premier, Social Sciences Abstracts, Web of Science, and Defense Technical Information Center. Because our interest was in DS that could apply to clinical decisions, we selected articles that (1) provided a review, overview, discussion of lessons learned, or an evaluation of design or implementation aspects of DS within a non-healthcare discipline and (2) involved an element of human judgment at the individual level, as opposed to decisions that can be fully automated or that are made at the organizational level. Clinical decisions share some similarities with decisions made by military commanders, business managers, and other leaders: they involve assessing new situations and choosing courses of action with major consequences, under time pressure, and with incomplete information. We identified seven high-level DS system design features from the non-healthcare literature that could be applied to CDS: providing broad, system-level perspectives; customizing interfaces to specific users and roles; making the DS reasoning transparent; presenting data effectively; generating multiple scenarios covering disparate outcomes (e.g., effective; effective with side effects; ineffective); allowing for contingent adaptations; and facilitating collaboration. The article provides examples of each feature. The DS literature also emphasizes the importance of organizational culture and training in implementation success. The literature contrasts "rational-analytic" vs. "naturalistic-intuitive" decision-making styles, but the best approach is often a balanced approach that combines both styles. It is also important for DS systems to enable exploration of multiple assumptions, and incorporation of new information in response to changing circumstances. Complex, high-level decision-making has common features across disciplines as seemingly disparate as defense, business, and healthcare. National efforts to advance the health information technology agenda through broader CDS adoption could benefit by applying the DS principles identified in this review.

  15. Qualitative analysis of vendor discussions on the procurement of Computerised Physician Order Entry and Clinical Decision Support systems in hospitals

    PubMed Central

    Cresswell, Kathrin M; Lee, Lisa; Slee, Ann; Coleman, Jamie; Bates, David W; Sheikh, Aziz

    2015-01-01

    Objectives We studied vendor perspectives about potentially transferable lessons for implementing organisations and national strategies surrounding the procurement of Computerised Physician Order Entry (CPOE)/Clinical Decision Support (CDS) systems in English hospitals. Setting Data were collected from digitally audio-recorded discussions from a series of CPOE/CDS vendor round-table discussions held in September 2014 in the UK. Participants Nine participants, representing 6 key vendors operating in the UK, attended. The discussions were transcribed verbatim and thematically analysed. Results Vendors reported a range of challenges surrounding the procurement and contracting processes of CPOE/CDS systems, including hospitals’ inability to adequately assess their own needs and then select a suitable product, rushed procurement and implementation processes that resulted in difficulties in meaningfully engaging with vendors, as well as challenges relating to contracting leading to ambiguities in implementation roles. Consequently, relationships between system vendors and hospitals were often strained, the vendors attributing this to a lack of hospital management's appreciation of the complexities associated with implementation efforts. Future anticipated challenges included issues surrounding the standardisation of data to enable their aggregation across systems for effective secondary uses, and implementation of data exchange with providers outside the hospital. Conclusions Our results indicate that there are significant issues surrounding capacity to procure and optimise CPOE/CDS systems among UK hospitals. There is an urgent need to encourage more synergistic and collaborative working between providers and vendors and for a more centralised support for National Health Service hospitals, which draws on a wider body of experience, including a formalised procurement framework with value-based product specifications. PMID:26503385

  16. Clinical Decision Support Tools for Selecting Interventions for Patients with Disabling Musculoskeletal Disorders: A Scoping Review.

    PubMed

    Gross, Douglas P; Armijo-Olivo, Susan; Shaw, William S; Williams-Whitt, Kelly; Shaw, Nicola T; Hartvigsen, Jan; Qin, Ziling; Ha, Christine; Woodhouse, Linda J; Steenstra, Ivan A

    2016-09-01

    Purpose We aimed to identify and inventory clinical decision support (CDS) tools for helping front-line staff select interventions for patients with musculoskeletal (MSK) disorders. Methods We used Arksey and O'Malley's scoping review framework which progresses through five stages: (1) identifying the research question; (2) identifying relevant studies; (3) selecting studies for analysis; (4) charting the data; and (5) collating, summarizing and reporting results. We considered computer-based, and other available tools, such as algorithms, care pathways, rules and models. Since this research crosses multiple disciplines, we searched health care, computing science and business databases. Results Our search resulted in 4605 manuscripts. Titles and abstracts were screened for relevance. The reliability of the screening process was high with an average percentage of agreement of 92.3 %. Of the located articles, 123 were considered relevant. Within this literature, there were 43 CDS tools located. These were classified into 3 main areas: computer-based tools/questionnaires (n = 8, 19 %), treatment algorithms/models (n = 14, 33 %), and clinical prediction rules/classification systems (n = 21, 49 %). Each of these areas and the associated evidence are described. The state of evidentiary support for CDS tools is still preliminary and lacks external validation, head-to-head comparisons, or evidence of generalizability across different populations and settings. Conclusions CDS tools, especially those employing rapidly advancing computer technologies, are under development and of potential interest to health care providers, case management organizations and funders of care. Based on the results of this scoping review, we conclude that these tools, models and systems should be subjected to further validation before they can be recommended for large-scale implementation for managing patients with MSK disorders.

  17. Impact of Computerized Decision Support on Blood Pressure Management and Control: A Randomized Controlled Trial

    PubMed Central

    Sequist, Thomas D.; Ayanian, John Z.; Shaykevich, Shimon; Fairchild, David G.; Orav, E. John; Bates, David W.

    2008-01-01

    BACKGROUND We conducted a cluster randomized controlled trial to examine the effectiveness of computerized decision support (CDS) designed to improve hypertension care and outcomes in a racially diverse sample of primary care patients. METHODS We randomized 2,027 adult patients receiving hypertension care in 14 primary care practices to either 18 months of their physicians receiving CDS for each hypertensive patient or to usual care without computerized support for the control group. We assessed prescribing of guideline-recommended drug therapy and levels of blood pressure control for patients in each group and examined if the effects of the intervention differed by patients’ race/ethnicity using interaction terms. MEASUREMENTS AND MAIN RESULTS Rates of blood pressure control were 42% at baseline and 46% at the outcome visit with no significant differences between groups. After adjustment for patients’ demographic and clinical characteristics, number of prior visits, and levels of baseline blood pressure control, there were no differences between intervention groups in the odds of outcome blood pressure control. The use of CDS to providers significantly improved Joint National Committee (JNC) guideline adherent medication prescribing compared to usual care (7% versus 5%, P < 0.001); the effects of the intervention remained after multivariable adjustment (odds ratio [OR] 1.39 [CI, 1.13–1.72]) and the effects of the intervention did not differ by patients’ race and ethnicity. CONCLUSIONS CDS improved appropriate medication prescribing with no improvement in disparities in care and overall blood pressure control. Future work focusing on improvement of these interventions and the study of other practical interventions to reduce disparities in hypertension-related outcomes is needed. PMID:18373141

  18. The Impact of Electronic Knowledge-Based Nursing Content and Decision-Support on Nursing-Sensitive Patient Outcomes

    DTIC Science & Technology

    2014-02-01

    aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information...if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE February 2014 2... Akre , et al., 2006) content and evidence-based clinical decision support (CDS) tools were embedded into the EHR of one large health care system. Since

  19. Using Best Practices to Extract, Organize, and Reuse Embedded Decision Support Content Knowledge Rules from Mature Clinical Systems

    PubMed Central

    DesAutels, Spencer J.; Fox, Zachary E.; Giuse, Dario A.; Williams, Annette M.; Kou, Qing-hua; Weitkamp, Asli; Neal R, Patel; Bettinsoli Giuse, Nunzia

    2016-01-01

    Clinical decision support (CDS) knowledge, embedded over time in mature medical systems, presents an interesting and complex opportunity for information organization, maintenance, and reuse. To have a holistic view of all decision support requires an in-depth understanding of each clinical system as well as expert knowledge of the latest evidence. This approach to clinical decision support presents an opportunity to unify and externalize the knowledge within rules-based decision support. Driven by an institutional need to prioritize decision support content for migration to new clinical systems, the Center for Knowledge Management and Health Information Technology teams applied their unique expertise to extract content from individual systems, organize it through a single extensible schema, and present it for discovery and reuse through a newly created Clinical Support Knowledge Acquisition and Archival Tool (CS-KAAT). CS-KAAT can build and maintain the underlying knowledge infrastructure needed by clinical systems. PMID:28269846

  20. Impact of a Commercially Available Clinical Decision Support Program on Provider Ordering Habits.

    PubMed

    Huber, Timothy C; Krishnaraj, Arun; Patrie, James; Gaskin, Cree M

    2018-05-18

    Clinical decision support (CDS) software designed around the ACR Appropriateness Criteria assists health care providers in choosing appropriate imaging studies at the time of order entry. The goal of this study was to determine the impact of commercially available CDS on the ordering habits of inpatient and emergency providers. In 2014, ACR Select was integrated into our electronic health record, though without displaying appropriateness scores in a "silent" mode for 6 months. Then, feedback regarding examination appropriateness was "turned on" at order entry for adult patients in the emergency and inpatient settings for 24 months. We retrospectively compared the appropriateness scores of imaging tests before and after displaying feedback at order entry and evaluated these data by modality and attending versus trainee status. The commercially available CDS-generated scores for 34% and 20.4% of pre- and postintervention studies, respectively. After feedback, the relative frequency of low utility studies decreased to 5.4% from 11%, and the relative frequency of indicated studies increased to 82% from 64.5%. This was most pronounced in trainees for whom the percentage of low utility studies decreased from 10.8% (95% confidence interval [CI]: 10.0%, 11.7%) to 4.8% (95% CI: 4.4%, 5.2%) and the percentage of indicated studies increased from 65.6% (95% CI: 64.3%, 66.9%) to 83.7% (83.0%, 84.3%). After implementation of a commercially available decision support tool integrated into the electronic health record, there was a significant improvement in imaging study appropriateness scores, more pronounced in studies ordered by trainees. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Assessment of readiness for clinical decision support to aid laboratory monitoring of immunosuppressive care at U.S. liver transplant centers.

    PubMed

    Jacobs, J; Weir, C; Evans, R S; Staes, C

    2014-01-01

    Following liver transplantation, patients require lifelong immunosuppressive care and monitoring. Computerized clinical decision support (CDS) has been shown to improve post-transplant immunosuppressive care processes and outcomes. The readiness of transplant information systems to implement computerized CDS to support post-transplant care is unknown. a) Describe the current clinical information system functionality and manual and automated processes for laboratory monitoring of immunosuppressive care, b) describe the use of guidelines that may be used to produce computable logic and the use of computerized alerts to support guideline adherence, and c) explore barriers to implementation of CDS in U.S. liver transplant centers. We developed a web-based survey using cognitive interviewing techniques. We surveyed 119 U.S. transplant programs that performed at least five liver transplantations per year during 2010-2012. Responses were summarized using descriptive analyses; barriers were identified using qualitative methods. Respondents from 80 programs (67% response rate) completed the survey. While 98% of programs reported having an electronic health record (EHR), all programs used paper-based manual processes to receive or track immunosuppressive laboratory results. Most programs (85%) reported that 30% or more of their patients used external laboratories for routine testing. Few programs (19%) received most external laboratory results as discrete data via electronic interfaces while most (80%) manually entered laboratory results into the EHR; less than half (42%) could integrate internal and external laboratory results. Nearly all programs had guidelines regarding pre-specified target ranges (92%) or testing schedules (97%) for managing immunosuppressive care. Few programs used computerized alerting to notify transplant coordinators of out-of-range (27%) or overdue laboratory results (20%). Use of EHRs is common, yet all liver transplant programs were largely dependent on manual paper-based processes to monitor immunosuppression for post-liver transplant patients. Similar immunosuppression guidelines provide opportunities for sharing CDS once integrated laboratory data are available.

  2. Making cognitive decision support work: Facilitating adoption, knowledge and behavior change through QI.

    PubMed

    Weir, Charlene; Brunker, Cherie; Butler, Jorie; Supiano, Mark A

    2017-07-01

    This paper evaluates the role of facilitation in the successful implementation of Computerized Decision Support (CDS). Facilitation processes include education, specialized computerized decision support, and work process reengineering. These techniques, as well as modeling and feedback enhance self-efficacy, which we propose is one of the factors that mediate the effectiveness of any CDS. In this study, outpatient clinics implemented quality improvement (QI) projects focused on improving geriatric care. Quality Improvement is the systematic process of improving quality through continuous measurement and targeted actions. The program, entitled "Advancing Geriatric Education through Quality Improvement" (AGE QI), consisted of a 6-month, QI based, intervention: (1) 2h didactic session, (2) 1h QI planning session, (3) computerized decision support design and implementation, (4) QI facilitation activities, (5) outcome feedback, and (6) 20h of CME. Specifically, we examined the impact of the QI based program on clinician's perceived self-efficacy in caring for older adults and the relationship of implementation support and facilitation on perceived success. The intervention was implemented at 3 institutions, 27 community healthcare system clinics, and 134 providers. This study reports the results of pre/post surveys for the forty-nine clinicians who completed the full CME program. Self-efficacy ratings for specific clinical behaviors related to care of older adults were assessed using a Likert based instrument. Self-ratings of efficacy improved across the following domains (depression, falls, end-of-life, functional status and medication management) and specifically in QI targeted domains and were associated with overall clinic improvements. Published by Elsevier Inc.

  3. A legal framework to enable sharing of Clinical Decision Support knowledge and services across institutional boundaries.

    PubMed

    Hongsermeier, Tonya; Maviglia, Saverio; Tsurikova, Lana; Bogaty, Dan; Rocha, Roberto A; Goldberg, Howard; Meltzer, Seth; Middleton, Blackford

    2011-01-01

    The goal of the CDS Consortium (CDSC) is to assess, define, demonstrate, and evaluate best practices for knowledge management and clinical decision support in healthcare information technology at scale - across multiple ambulatory care settings and Electronic Health Record technology platforms. In the course of the CDSC research effort, it became evident that a sound legal foundation was required for knowledge sharing and clinical decision support services in order to address data sharing, intellectual property, accountability, and liability concerns. This paper outlines the framework utilized for developing agreements in support of sharing, accessing, and publishing content via the CDSC Knowledge Management Portal as well as an agreement in support of deployment and consumption of CDSC developed web services in the context of a research project under IRB oversight.

  4. LAMDA at TREC CDS track 2015: Clinical Decision Support Track

    DTIC Science & Technology

    2015-11-20

    outperforms all the other vector space models supported by Elasticsearch. MetaMap is the online tool that maps biomedical text to the Metathesaurus, and...cases. The medical knowledge consists of 700,000 biomedical documents supported by the PubMed Central [3] which is online digital database freely...Science Research Program through the National Research Foundation (NRF) of Korea funded by the Ministry of Science, ICT , and Future Planning (MSIP

  5. Cross-vendor evaluation of key user-defined clinical decision support capabilities: a scenario-based assessment of certified electronic health records with guidelines for future development.

    PubMed

    McCoy, Allison B; Wright, Adam; Sittig, Dean F

    2015-09-01

    Clinical decision support (CDS) is essential for delivery of high-quality, cost-effective, and safe healthcare. The authors sought to evaluate the CDS capabilities across electronic health record (EHR) systems. We evaluated the CDS implementation capabilities of 8 Office of the National Coordinator for Health Information Technology Authorized Certification Body (ONC-ACB)-certified EHRs. Within each EHR, the authors attempted to implement 3 user-defined rules that utilized the various data and logic elements expected of typical EHRs and that represented clinically important evidenced-based care. The rules were: 1) if a patient has amiodarone on his or her active medication list and does not have a thyroid-stimulating hormone (TSH) result recorded in the last 12 months, suggest ordering a TSH; 2) if a patient has a hemoglobin A1c result >7% and does not have diabetes on his or her problem list, suggest adding diabetes to the problem list; and 3) if a patient has coronary artery disease on his or her problem list and does not have aspirin on the active medication list, suggest ordering aspirin. Most evaluated EHRs lacked some CDS capabilities; 5 EHRs were able to implement all 3 rules, and the remaining 3 EHRs were unable to implement any of the rules. One of these did not allow users to customize CDS rules at all. The most frequently found shortcomings included the inability to use laboratory test results in rules, limit rules by time, use advanced Boolean logic, perform actions from the alert interface, and adequately test rules. Significant improvements in the EHR certification and implementation procedures are necessary. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Comparison of Overridden Medication-related Clinical Decision Support in the Intensive Care Unit between a Commercial System and a Legacy System.

    PubMed

    Wong, Adrian; Wright, Adam; Seger, Diane L; Amato, Mary G; Fiskio, Julie M; Bates, David

    2017-08-23

    Electronic health records (EHRs) with clinical decision support (CDS) have shown to be effective at improving patient safety. Despite this, alerts delivered as part of CDS are overridden frequently, which is of concern in the critical care population as this group may have an increased risk of harm. Our organization recently transitioned from an internally-developed EHR to a commercial system. Data comparing various EHR systems, especially after transitions between EHRs, are needed to identify areas for improvement. To compare the two systems and identify areas for potential improvement with the new commercial system at a single institution. Overridden medication-related CDS alerts were included from October to December of the systems' respective years (legacy, 2011; commercial, 2015), restricted to three intensive care units. The two systems were compared with regards to CDS presentation and override rates for four types of CDS: drug-allergy, drug-drug interaction (DDI), geriatric and renal alerts. A post hoc analysis to evaluate for adverse drug events (ADEs) potentially resulting from overridden alerts was performed for 'contraindicated' DDIs via chart review. There was a significant increase in provider exposure to alerts and alert overrides in the commercial system (commercial: n=5,535; legacy: n=1,030). Rates of overrides were higher for the allergy and DDI alerts (p<0.001) in the commercial system. Geriatric and renal alerts were significantly different in incidence and presentation between the two systems. No ADEs were identified in an analysis of 43 overridden contraindicated DDI alerts. The vendor system had much higher rates of both alerts and overrides, although we did not find evidence of harm in a review of DDIs which were overridden. We propose recommendations for improving our current system which may be helpful to other similar institutions; improving both alert presentation and the underlying knowledge base appear important.

  7. Advancing clinical decision support using lessons from outside of healthcare: an interdisciplinary systematic review

    PubMed Central

    2012-01-01

    Background Greater use of computerized decision support (DS) systems could address continuing safety and quality problems in healthcare, but the healthcare field has struggled to implement DS technology. This study surveys DS experience across multiple non-healthcare disciplines for new insights that are generalizable to healthcare provider decisions. In particular, it sought design principles and lessons learned from the other disciplines that could inform efforts to accelerate the adoption of clinical decision support (CDS). Methods Our systematic review drew broadly from non-healthcare databases in the basic sciences, social sciences, humanities, engineering, business, and defense: PsychINFO, BusinessSource Premier, Social Sciences Abstracts, Web of Science, and Defense Technical Information Center. Because our interest was in DS that could apply to clinical decisions, we selected articles that (1) provided a review, overview, discussion of lessons learned, or an evaluation of design or implementation aspects of DS within a non-healthcare discipline and (2) involved an element of human judgment at the individual level, as opposed to decisions that can be fully automated or that are made at the organizational level. Results Clinical decisions share some similarities with decisions made by military commanders, business managers, and other leaders: they involve assessing new situations and choosing courses of action with major consequences, under time pressure, and with incomplete information. We identified seven high-level DS system design features from the non-healthcare literature that could be applied to CDS: providing broad, system-level perspectives; customizing interfaces to specific users and roles; making the DS reasoning transparent; presenting data effectively; generating multiple scenarios covering disparate outcomes (e.g., effective; effective with side effects; ineffective); allowing for contingent adaptations; and facilitating collaboration. The article provides examples of each feature. The DS literature also emphasizes the importance of organizational culture and training in implementation success. The literature contrasts “rational-analytic” vs. “naturalistic-intuitive” decision-making styles, but the best approach is often a balanced approach that combines both styles. It is also important for DS systems to enable exploration of multiple assumptions, and incorporation of new information in response to changing circumstances. Conclusions Complex, high-level decision-making has common features across disciplines as seemingly disparate as defense, business, and healthcare. National efforts to advance the health information technology agenda through broader CDS adoption could benefit by applying the DS principles identified in this review. PMID:22900537

  8. The Arden Syntax standard for clinical decision support: experiences and directions.

    PubMed

    Samwald, Matthias; Fehre, Karsten; de Bruin, Jeroen; Adlassnig, Klaus-Peter

    2012-08-01

    Arden Syntax is a widely recognized standard for representing clinical and scientific knowledge in an executable format. It has a history that reaches back until 1989 and is currently maintained by the Health Level 7 (HL7) organization. We created a production-ready development environment, compiler, rule engine and application server for Arden Syntax. Over the course of several years, we have applied this Arden - Syntax - based CDS system in a wide variety of clinical problem domains, such as hepatitis serology interpretation, monitoring of nosocomial infections or the prediction of metastatic events in melanoma patients. We found the Arden Syntax standard to be very suitable for the practical implementation of CDS systems. Among the advantages of Arden Syntax are its status as an actively developed HL7 standard, the readability of the syntax, and various syntactic features such as flexible list handling. A major challenge we encountered was the technical integration of our CDS systems in existing, heterogeneous health information systems. To address this issue, we are currently working on incorporating the HL7 standard GELLO, which provides a standardized interface and query language for accessing data in health information systems. We hope that these planned extensions of the Arden Syntax might eventually help in realizing the vision of a global, interoperable and shared library of clinical decision support knowledge. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Clinical-decision support based on medical literature: A complex network approach

    NASA Astrophysics Data System (ADS)

    Jiang, Jingchi; Zheng, Jichuan; Zhao, Chao; Su, Jia; Guan, Yi; Yu, Qiubin

    2016-10-01

    In making clinical decisions, clinicians often review medical literature to ensure the reliability of diagnosis, test, and treatment because the medical literature can answer clinical questions and assist clinicians making clinical decisions. Therefore, finding the appropriate literature is a critical problem for clinical-decision support (CDS). First, the present study employs search engines to retrieve relevant literature about patient records. However, the result of the traditional method is usually unsatisfactory. To improve the relevance of the retrieval result, a medical literature network (MLN) based on these retrieved papers is constructed. Then, we show that this MLN has small-world and scale-free properties of a complex network. According to the structural characteristics of the MLN, we adopt two methods to further identify the potential relevant literature in addition to the retrieved literature. By integrating these potential papers into the MLN, a more comprehensive MLN is built to answer the question of actual patient records. Furthermore, we propose a re-ranking model to sort all papers by relevance. We experimentally find that the re-ranking model can improve the normalized discounted cumulative gain of the results. As participants of the Text Retrieval Conference 2015, our clinical-decision method based on the MLN also yields higher scores than the medians in most topics and achieves the best scores for topics: #11 and #12. These research results indicate that our study can be used to effectively assist clinicians in making clinical decisions, and the MLN can facilitate the investigation of CDS.

  10. Automation bias in electronic prescribing.

    PubMed

    Lyell, David; Magrabi, Farah; Raban, Magdalena Z; Pont, L G; Baysari, Melissa T; Day, Richard O; Coiera, Enrico

    2017-03-16

    Clinical decision support (CDS) in e-prescribing can improve safety by alerting potential errors, but introduces new sources of risk. Automation bias (AB) occurs when users over-rely on CDS, reducing vigilance in information seeking and processing. Evidence of AB has been found in other clinical tasks, but has not yet been tested with e-prescribing. This study tests for the presence of AB in e-prescribing and the impact of task complexity and interruptions on AB. One hundred and twenty students in the final two years of a medical degree prescribed medicines for nine clinical scenarios using a simulated e-prescribing system. Quality of CDS (correct, incorrect and no CDS) and task complexity (low, low + interruption and high) were varied between conditions. Omission errors (failure to detect prescribing errors) and commission errors (acceptance of false positive alerts) were measured. Compared to scenarios with no CDS, correct CDS reduced omission errors by 38.3% (p < .0001, n = 120), 46.6% (p < .0001, n = 70), and 39.2% (p < .0001, n = 120) for low, low + interrupt and high complexity scenarios respectively. Incorrect CDS increased omission errors by 33.3% (p < .0001, n = 120), 24.5% (p < .009, n = 82), and 26.7% (p < .0001, n = 120). Participants made commission errors, 65.8% (p < .0001, n = 120), 53.5% (p < .0001, n = 82), and 51.7% (p < .0001, n = 120). Task complexity and interruptions had no impact on AB. This study found evidence of AB omission and commission errors in e-prescribing. Verification of CDS alerts is key to avoiding AB errors. However, interventions focused on this have had limited success to date. Clinicians should remain vigilant to the risks of CDS failures and verify CDS.

  11. The evolution of the market for commercial computerized physician order entry and computerized decision support systems for prescribing.

    PubMed

    Mozaffar, Hajar; Williams, Robin; Cresswell, Kathrin; Morrison, Zoe; Bates, David W; Sheikh, Aziz

    2016-03-01

    To understand the evolving market of commercial off-the-shelf Computerized Physician Order Entry (CPOE) and Computerized Decision Support (CDS) applications and its effects on their uptake and implementation in English hospitals. Although CPOE and CDS vendors have been quick to enter the English market, uptake has been slow and uneven. To investigate this, the authors undertook qualitative ethnography of vendors and adopters of hospital CPOE/CDS systems in England. The authors collected data from semi-structured interviews with 11 individuals from 4 vendors, including the 2 most entrenched suppliers, and 6 adopter hospitals, and 21 h of ethnographic observation of 2 user groups, and 1 vendor event. The research and analysis was informed by insights from studies of the evolution of technology fields and the emergence of generic COTS enterprise solutions. Four key themes emerged: (1) adoption of systems that had been developed outside of England, (2) vendors' configuration and customization strategies, (3) localized adopter practices vs generic systems, and (4) unrealistic adopter demands. Evidence for our over-arching finding concerning the current immaturity of the market was derived from vendors' strategies, adopters' reactions to the technology, and policy makers' incomplete insights. The CPOE/CDS market in England is still in an emergent phase. The rapid entrance of diverse products, triggered by federal policy initiatives, has resulted in premature adoption of systems that do not yet adequately meet the needs of hospitals. Vendors and adopters lacked understanding of how to design and implement generic solutions to meet diverse user needs. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Physicians’ use of computerized clinical decision supports to improve medication management in the elderly – the Seniors Medication Alert and Review Technology intervention

    PubMed Central

    Alagiakrishnan, Kannayiram; Wilson, Patricia; Sadowski, Cheryl A; Rolfson, Darryl; Ballermann, Mark; Ausford, Allen; Vermeer, Karla; Mohindra, Kunal; Romney, Jacques; Hayward, Robert S

    2016-01-01

    Background Elderly people (aged 65 years or more) are at increased risk of polypharmacy (five or more medications), inappropriate medication use, and associated increased health care costs. The use of clinical decision support (CDS) within an electronic medical record (EMR) could improve medication safety. Methods Participatory action research methods were applied to preproduction design and development and postproduction optimization of an EMR-embedded CDS implementation of the Beers’ Criteria for medication management and the Cockcroft–Gault formula for estimating glomerular filtration rates (GFR). The “Seniors Medication Alert and Review Technologies” (SMART) intervention was used in primary care and geriatrics specialty clinics. Passive (chart messages) and active (order-entry alerts) prompts exposed potentially inappropriate medications, decreased GFR, and the possible need for medication adjustments. Physician reactions were assessed using surveys, EMR simulations, focus groups, and semi-structured interviews. EMR audit data were used to identify eligible patient encounters, the frequency of CDS events, how alerts were managed, and when evidence links were followed. Results Analysis of subjective data revealed that most clinicians agreed that CDS appeared at appropriate times during patient care. Although managing alerts incurred a modest time burden, most also agreed that workflow was not disrupted. Prevalent concerns related to clinician accountability and potential liability. Approximately 36% of eligible encounters triggered at least one SMART alert, with GFR alert, and most frequent medication warnings were with hypnotics and anticholinergics. Approximately 25% of alerts were overridden and ~15% elicited an evidence check. Conclusion While most SMART alerts validated clinician choices, they were received as valuable reminders for evidence-informed care and education. Data from this study may aid other attempts to implement Beers’ Criteria in ambulatory care EMRs. PMID:26869776

  13. Development and use of active clinical decision support for preemptive pharmacogenomics

    PubMed Central

    Bell, Gillian C; Crews, Kristine R; Wilkinson, Mark R; Haidar, Cyrine E; Hicks, J Kevin; Baker, Donald K; Kornegay, Nancy M; Yang, Wenjian; Cross, Shane J; Howard, Scott C; Freimuth, Robert R; Evans, William E; Broeckel, Ulrich; Relling, Mary V; Hoffman, James M

    2014-01-01

    Background Active clinical decision support (CDS) delivered through an electronic health record (EHR) facilitates gene-based drug prescribing and other applications of genomics to patient care. Objective We describe the development, implementation, and evaluation of active CDS for multiple pharmacogenetic test results reported preemptively. Materials and methods Clinical pharmacogenetic test results accompanied by clinical interpretations are placed into the patient's EHR, typically before a relevant drug is prescribed. Problem list entries created for high-risk phenotypes provide an unambiguous trigger for delivery of post-test alerts to clinicians when high-risk drugs are prescribed. In addition, pre-test alerts are issued if a very-high risk medication is prescribed (eg, a thiopurine), prior to the appropriate pharmacogenetic test result being entered into the EHR. Our CDS can be readily modified to incorporate new genes or high-risk drugs as they emerge. Results Through November 2012, 35 customized pharmacogenetic rules have been implemented, including rules for TPMT with azathioprine, thioguanine, and mercaptopurine, and for CYP2D6 with codeine, tramadol, amitriptyline, fluoxetine, and paroxetine. Between May 2011 and November 2012, the pre-test alerts were electronically issued 1106 times (76 for thiopurines and 1030 for drugs metabolized by CYP2D6), and the post-test alerts were issued 1552 times (1521 for TPMT and 31 for CYP2D6). Analysis of alert outcomes revealed that the interruptive CDS appropriately guided prescribing in 95% of patients for whom they were issued. Conclusions Our experience illustrates the feasibility of developing computational systems that provide clinicians with actionable alerts for gene-based drug prescribing at the point of care. PMID:23978487

  14. Improved blood utilization using real-time clinical decision support.

    PubMed

    Goodnough, Lawrence T; Shieh, Lisa; Hadhazy, Eric; Cheng, Nathalie; Khari, Paul; Maggio, Paul

    2014-05-01

    We analyzed blood utilization at Stanford Hospital and Clinics after implementing real-time clinical decision support (CDS) and best practice alerts (BPAs) into physician order entry (POE) for blood transfusions. A clinical effectiveness (CE) team developed consensus with a suggested transfusion threshold of a hemoglobin (Hb) level of 7 g/dL, or 8 g/dL for patients with acute coronary syndromes. The CDS was implemented in July 2010 and consisted of an interruptive BPA at POE, a link to relevant literature, and an "acknowledgment reason" for the blood order. The percentage of blood ordered for patients whose most recent Hb level exceeded 8 g/dL ranged at baseline from 57% to 66%; from the education intervention by the CE team August 2009 to July 2010, the percentage decreased to a range of 52% to 56% (p = 0.01); and after implementation of CDS and BPA, by end of December 2010 the percentage of patients transfused outside the guidelines decreased to 35% (p = 0.02) and has subsequently remained below 30%. For the most recent interval, only 27% (767 of 2890) of transfusions occurred in patients outside guidelines. Comparing 2009 to 2012, despite an increase in annual case mix index from 1.952 to 2.026, total red blood cell (RBC) transfusions decreased by 7186 units, or 24%. The estimated net savings for RBC units (at $225/unit) in purchase costs for 2012 compared to 2009 was $1,616,750. Real-time CDS has significantly improved blood utilization. This system of concurrent review can be used by health care institutions, quality departments, and transfusion services to reduce blood transfusions. © 2013 American Association of Blood Banks.

  15. Developing knowledge resources to support precision medicine: principles from the Clinical Pharmacogenetics Implementation Consortium (CPIC).

    PubMed

    Hoffman, James M; Dunnenberger, Henry M; Kevin Hicks, J; Caudle, Kelly E; Whirl Carrillo, Michelle; Freimuth, Robert R; Williams, Marc S; Klein, Teri E; Peterson, Josh F

    2016-07-01

    To move beyond a select few genes/drugs, the successful adoption of pharmacogenomics into routine clinical care requires a curated and machine-readable database of pharmacogenomic knowledge suitable for use in an electronic health record (EHR) with clinical decision support (CDS). Recognizing that EHR vendors do not yet provide a standard set of CDS functions for pharmacogenetics, the Clinical Pharmacogenetics Implementation Consortium (CPIC) Informatics Working Group is developing and systematically incorporating a set of EHR-agnostic implementation resources into all CPIC guidelines. These resources illustrate how to integrate pharmacogenomic test results in clinical information systems with CDS to facilitate the use of patient genomic data at the point of care. Based on our collective experience creating existing CPIC resources and implementing pharmacogenomics at our practice sites, we outline principles to define the key features of future knowledge bases and discuss the importance of these knowledge resources for pharmacogenomics and ultimately precision medicine. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. The Use of Clinical Decision Support in Reducing Diagnosis of and Treatment of Asymptomatic Bacteriuria.

    PubMed

    Keller, Sara C; Feldman, Leonard; Smith, Janessa; Pahwa, Amit; Cosgrove, Sara E; Chida, Natasha

    2018-06-01

    Clinical decision support (CDS) embedded within the electronic health record (EHR) is a potential antibiotic stewardship strategy for hospitalized patients. Reduction in urine testing and treating asymptomatic bacteriuria (ASB) is an important strategy to promote antibiotic stewardship. We created an intervention focused on reducing urine testing for asymptomatic patients at a large tertiary care center. The objective of this study was to design an intervention to reduce unnecessary urinalysis and urine culture (UC) orders as well as the treatment of ASB. We performed a quasiexperimental study among adult inpatients at a single academic institution. We implemented a bundled intervention, including information broadcast in newsletters, hospitalwide screensavers, and passive CDS messages in the EHR. We investigated the impact of this strategy on urinalysis, UC orders, and on the treatment of ASB by using an interrupted time series analysis. Our intervention led to reduced UC order as well as reduced antibiotic orders in response to urinalysis orders and UC results. This easily implementable bundle may play an important role as an antibiotic stewardship strategy. © 2018 Society of Hospital Medicine.

  17. Implementation of a Mobile Clinical Decision Support Application to Augment Local Antimicrobial Stewardship.

    PubMed

    Hoff, Brian M; Ford, Diana C; Ince, Dilek; Ernst, Erika J; Livorsi, Daniel J; Heintz, Brett H; Masse, Vincent; Brownlee, Michael J; Ford, Bradley A

    2018-01-01

    Medical applications for mobile devices allow clinicians to leverage microbiological data and standardized guidelines to treat patients with infectious diseases. We report the implementation of a mobile clinical decision support (CDS) application to augment local antimicrobial stewardship. We detail the implementation of our mobile CDS application over 20 months. Application utilization data were collected and evaluated using descriptive statistics to quantify the impact of our implementation. Project initiation focused on engaging key stakeholders, developing a business case, and selecting a mobile platform. The preimplementation phase included content development, creation of a pathway for content approval within the hospital committee structure, engaging clinical leaders, and formatting the first version of the guide. Implementation involved a media campaign, staff education, and integration within the electronic medical record and hospital mobile devices. The postimplementation phase required ongoing quality improvement, revision of outdated content, and repeated staff education. The evaluation phase included a guide utilization analysis, reporting to hospital leadership, and sustainability and innovation planning. The mobile application was downloaded 3056 times and accessed 9259 times during the study period. The companion web viewer was accessed 8214 times. Successful implementation of a customizable mobile CDS tool enabled our team to expand beyond microbiological data to clinical diagnosis, treatment, and antimicrobial stewardship, broadening our influence on antimicrobial prescribing and incorporating utilization data to inspire new quality and safety initiatives. Further studies are needed to assess the impact on antimicrobial utilization, infection control measures, and patient care outcomes.

  18. Pharmacogenomic knowledge representation, reasoning and genome-based clinical decision support based on OWL 2 DL ontologies.

    PubMed

    Samwald, Matthias; Miñarro Giménez, Jose Antonio; Boyce, Richard D; Freimuth, Robert R; Adlassnig, Klaus-Peter; Dumontier, Michel

    2015-02-22

    Every year, hundreds of thousands of patients experience treatment failure or adverse drug reactions (ADRs), many of which could be prevented by pharmacogenomic testing. However, the primary knowledge needed for clinical pharmacogenomics is currently dispersed over disparate data structures and captured in unstructured or semi-structured formalizations. This is a source of potential ambiguity and complexity, making it difficult to create reliable information technology systems for enabling clinical pharmacogenomics. We developed Web Ontology Language (OWL) ontologies and automated reasoning methodologies to meet the following goals: 1) provide a simple and concise formalism for representing pharmacogenomic knowledge, 2) finde errors and insufficient definitions in pharmacogenomic knowledge bases, 3) automatically assign alleles and phenotypes to patients, 4) match patients to clinically appropriate pharmacogenomic guidelines and clinical decision support messages and 5) facilitate the detection of inconsistencies and overlaps between pharmacogenomic treatment guidelines from different sources. We evaluated different reasoning systems and test our approach with a large collection of publicly available genetic profiles. Our methodology proved to be a novel and useful choice for representing, analyzing and using pharmacogenomic data. The Genomic Clinical Decision Support (Genomic CDS) ontology represents 336 SNPs with 707 variants; 665 haplotypes related to 43 genes; 22 rules related to drug-response phenotypes; and 308 clinical decision support rules. OWL reasoning identified CDS rules with overlapping target populations but differing treatment recommendations. Only a modest number of clinical decision support rules were triggered for a collection of 943 public genetic profiles. We found significant performance differences across available OWL reasoners. The ontology-based framework we developed can be used to represent, organize and reason over the growing wealth of pharmacogenomic knowledge, as well as to identify errors, inconsistencies and insufficient definitions in source data sets or individual patient data. Our study highlights both advantages and potential practical issues with such an ontology-based approach.

  19. A combined paging alert and web-based instrument alters clinician behavior and shortens hospital length of stay in acute pancreatitis.

    PubMed

    Dimagno, Matthew J; Wamsteker, Erik-Jan; Rizk, Rafat S; Spaete, Joshua P; Gupta, Suraj; Sahay, Tanya; Costanzo, Jeffrey; Inadomi, John M; Napolitano, Lena M; Hyzy, Robert C; Desmond, Jeff S

    2014-03-01

    There are many published clinical guidelines for acute pancreatitis (AP). Implementation of these recommendations is variable. We hypothesized that a clinical decision support (CDS) tool would change clinician behavior and shorten hospital length of stay (LOS). Observational study, entitled, The AP Early Response (TAPER) Project. Tertiary center emergency department (ED) and hospital. Two consecutive samplings of patients having ICD-9 code (577.0) for AP were generated from the emergency department (ED) or hospital admissions. Diagnosis of AP was based on conventional Atlanta criteria. The Pre-TAPER-CDS-Tool group (5/30/06-6/22/07) had 110 patients presenting to the ED with AP per 976 ICD-9 (577.0) codes and the Post-TAPER-CDS-Tool group (5/30/06-6/22/07) had 113 per 907 ICD-9 codes (7/14/10-5/5/11). The TAPER-CDS-Tool, developed 12/2008-7/14/2010, is a combined early, automated paging-alert system, which text pages ED clinicians about a patient with AP and an intuitive web-based point-of-care instrument, consisting of seven early management recommendations. The pre- vs. post-TAPER-CDS-Tool groups had similar baseline characteristics. The post-TAPER-CDS-Tool group met two management goals more frequently than the pre-TAPER-CDS-Tool group: risk stratification (P<0.0001) and intravenous fluids >6L/1st 0-24 h (P=0.0003). Mean (s.d.) hospital LOS was significantly shorter in the post-TAPER-CDS-Tool group (4.6 (3.1) vs. 6.7 (7.0) days, P=0.0126). Multivariate analysis identified four independent variables for hospital LOS: the TAPER-CDS-Tool associated with shorter LOS (P=0.0049) and three variables associated with longer LOS: Japanese severity score (P=0.0361), persistent organ failure (P=0.0088), and local pancreatic complications (<0.0001). The TAPER-CDS-Tool is associated with changed clinician behavior and shortened hospital LOS, which has significant financial implications.

  20. Evaluation of a novel electronic genetic screening and clinical decision support tool in prenatal clinical settings.

    PubMed

    Edelman, Emily A; Lin, Bruce K; Doksum, Teresa; Drohan, Brian; Edelson, Vaughn; Dolan, Siobhan M; Hughes, Kevin; O'Leary, James; Vasquez, Lisa; Copeland, Sara; Galvin, Shelley L; DeGroat, Nicole; Pardanani, Setul; Gregory Feero, W; Adams, Claire; Jones, Renee; Scott, Joan

    2014-07-01

    "The Pregnancy and Health Profile" (PHP) is a free prenatal genetic screening and clinical decision support (CDS) software tool for prenatal providers. PHP collects family health history (FHH) during intake and provides point-of-care risk assessment for providers and education for patients. This pilot study evaluated patient and provider responses to PHP and effects of using PHP in practice. PHP was implemented in four clinics. Surveys assessed provider confidence and knowledge and patient and provider satisfaction with PHP. Data on the implementation process were obtained through semi-structured interviews with administrators. Quantitative survey data were analyzed using Chi square test, Fisher's exact test, paired t tests, and multivariate logistic regression. Open-ended survey questions and interviews were analyzed using qualitative thematic analysis. Of the 83% (513/618) of patients that provided feedback, 97% felt PHP was easy to use and 98% easy to understand. Thirty percent (21/71) of participating physicians completed both pre- and post-implementation feedback surveys [13 obstetricians (OBs) and 8 family medicine physicians (FPs)]. Confidence in managing genetic risks significantly improved for OBs on 2/6 measures (p values ≤0.001) but not for FPs. Physician knowledge did not significantly change. Providers reported value in added patient engagement and reported mixed feedback about the CDS report. We identified key steps, resources, and staff support required to implement PHP in a clinical setting. To our knowledge, this study is the first to report on the integration of patient-completed, electronically captured and CDS-enabled FHH software into primary prenatal practice. PHP is acceptable to patients and providers. Key to successful implementation in the future will be customization options and interoperability with electronic health records.

  1. Census Data System of the Management Information System for Occupational Education: Guidelines and Instructions for Reporting. CDS Document No. 1.

    ERIC Educational Resources Information Center

    Management and Information System for Occupational Education, Winchester, MA.

    The MISOE Census Data System (CDS) is one of two major subsystems of an integrated management information system (MISOE), which was developed to provide occupational education managers with comprehensive data on which to base rational management decisions. Essentially, CDS contains descriptive information systematically structured in a manner…

  2. Toward best practice: leveraging the electronic patient record as a clinical data warehouse.

    PubMed

    Ledbetter, C S; Morgan, M W

    2001-01-01

    Automating clinical and administrative processes via an electronic patient record (EPR) gives clinicians the point-of-care tools they need to deliver better patient care. However, to improve clinical practice as a whole and then evaluate it, healthcare must go beyond basic automation and convert EPR data into aggregated, multidimensional information. Unfortunately, few EPR systems have the established, powerful analytical clinical data warehouses (CDWs) required for this conversion. This article describes how an organization can support best practice by leveraging a CDW that is fully integrated into its EPR and clinical decision support (CDS) system. The article (1) discusses the requirements for comprehensive CDS, including on-line analytical processing (OLAP) of data at both transactional and aggregate levels, (2) suggests that the transactional data acquired by an OLTP EPR system must be remodeled to support retrospective, population-based, aggregate analysis of those data, and (3) concludes that this aggregate analysis is best provided by a separate CDW system.

  3. Clinical Decision Support to Efficiently Identify Patients Eligible for Advanced Heart Failure Therapies.

    PubMed

    Evans, R Scott; Kfoury, Abdallah G; Horne, Benjamin D; Lloyd, James F; Benuzillo, Jose; Rasmusson, Kismet D; Roberts, Colleen; Lappé, Donald L

    2017-10-01

    Patients who need and receive timely advanced heart failure (HF) therapies have better long-term survival. However, many of these patients are not identified and referred as soon as they should be. A clinical decision support (CDS) application sent secure email notifications to HF patients' providers when they transitioned to advanced disease. Patients identified with CDS in 2015 were compared with control patients from 2013 to 2014. Kaplan-Meier methods and Cox regression were used in this intention-to-treat analysis to compare differences between visits to specialized and survival. Intervention patients were referred to specialized heart facilities significantly more often within 30 days (57% vs 34%; P < .001), 60 days (69% vs 44%; P < .0001), 90 days (73% vs 49%; P < .0001), and 180 days (79% vs 58%; P < .0001). Age and sex did not predict heart facility visits, but renal disease did and patients of nonwhite race were less likely to visit specialized heart facilities. Significantly more intervention patients were found to be alive at 30 (95% vs 92%; P = .036), 60 (95% vs 90%; P = .0013), 90 (94% vs 87%; P = .0002), and 180 days (92% vs 84%; P = .0001). Age, sex, and some comorbid diseases were also predictors of mortality, but race was not. We found that CDS can facilitate the early identification of patients needing advanced HF therapy and that its use was associated with significantly more patients visiting specialized heart facilities and longer survival. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Influencing Anesthesia Provider Behavior Using Anesthesia Information Management System Data for Near Real-Time Alerts and Post Hoc Reports.

    PubMed

    Epstein, Richard H; Dexter, Franklin; Patel, Neil

    2015-09-01

    In this review article, we address issues related to using data from anesthesia information management systems (AIMS) to deliver near real-time alerts via AIMS workstation popups and/or alphanumeric pagers and post hoc reports via e-mail. We focus on reports and alerts for influencing the behavior of anesthesia providers (i.e., anesthesiologists, anesthesia residents, and nurse anesthetists). Multiple studies have shown that anesthesia clinical decision support (CDS) improves adherence to protocols and increases financial performance through facilitation of billing, regulatory, and compliance documentation; however, improved clinical outcomes have not been demonstrated. We inform developers and users of feedback systems about the multitude of concerns to consider during development and implementation of CDS to increase its effectiveness and to mitigate its potentially disruptive aspects. We discuss the timing and modalities used to deliver messages, implications of outlier-only versus individualized feedback, the need to consider possible unintended consequences of such feedback, regulations, sustainability, and portability among systems. We discuss statistical issues related to the appropriate evaluation of CDS efficacy. We provide a systematic review of the published literature (indexed in PubMed) of anesthesia CDS and offer 2 case studies of CDS interventions using AIMS data from our own institution illustrating the salient points. Because of the considerable expense and complexity of maintaining near real-time CDS systems, as compared with providing individual reports via e-mail after the fact, we suggest that if the same goal can be accomplished via delayed reporting versus immediate feedback, the former approach is preferable. Nevertheless, some processes require near real-time alerts to produce the desired improvement. Post hoc e-mail reporting from enterprise-wide electronic health record systems is straightforward and can be accomplished using system-independent pathways (e.g., via built-in e-mail support provided by the relational database management system). However, for some of these enterprise-wide systems, near real-time data access, necessary for CDS that generates concurrent alerts, has been challenging to implement.

  5. Future of electronic health records: implications for decision support.

    PubMed

    Rothman, Brian; Leonard, Joan C; Vigoda, Michael M

    2012-01-01

    The potential benefits of the electronic health record over traditional paper are many, including cost containment, reductions in errors, and improved compliance by utilizing real-time data. The highest functional level of the electronic health record (EHR) is clinical decision support (CDS) and process automation, which are expected to enhance patient health and healthcare. The authors provide an overview of the progress in using patient data more efficiently and effectively through clinical decision support to improve health care delivery, how decision support impacts anesthesia practice, and how some are leading the way using these systems to solve need-specific issues. Clinical decision support uses passive or active decision support to modify clinician behavior through recommendations of specific actions. Recommendations may reduce medication errors, which would result in considerable savings by avoiding adverse drug events. In selected studies, clinical decision support has been shown to decrease the time to follow-up actions, and prediction has proved useful in forecasting patient outcomes, avoiding costs, and correctly prompting treatment plan modifications by clinicians before engaging in decision-making. Clinical documentation accuracy and completeness is improved by an electronic health record and greater relevance of care data is delivered. Clinical decision support may increase clinician adherence to clinical guidelines, but educational workshops may be equally effective. Unintentional consequences of clinical decision support, such as alert desensitization, can decrease the effectiveness of a system. Current anesthesia clinical decision support use includes antibiotic administration timing, improved documentation, more timely billing, and postoperative nausea and vomiting prophylaxis. Electronic health record implementation offers data-mining opportunities to improve operational, financial, and clinical processes. Using electronic health record data in real-time for decision support and process automation has the potential to both reduce costs and improve the quality of patient care. © 2012 Mount Sinai School of Medicine.

  6. Feasibility of using algorithm-based clinical decision support for symptom assessment and management in lung cancer.

    PubMed

    Cooley, Mary E; Blonquist, Traci M; Catalano, Paul J; Lobach, David F; Halpenny, Barbara; McCorkle, Ruth; Johns, Ellis B; Braun, Ilana M; Rabin, Michael S; Mataoui, Fatma Zohra; Finn, Kathleen; Berry, Donna L; Abrahm, Janet L

    2015-01-01

    Distressing symptoms interfere with the quality of life in patients with lung cancer. Algorithm-based clinical decision support (CDS) to improve evidence-based management of isolated symptoms seems promising, but no reports yet address multiple symptoms. This study examined the feasibility of CDS for a Symptom Assessment and Management Intervention targeting common symptoms in patients with lung cancer (SAMI-L) in ambulatory oncology. The study objectives were to evaluate completion and delivery rates of the SAMI-L report and clinician adherence to the algorithm-based recommendations. Patients completed a web-based symptom assessment and SAMI-L created tailored recommendations for symptom management. Completion of assessments and delivery of reports were recorded. Medical record review assessed clinician adherence to recommendations. Feasibility was defined as 75% or higher report completion and delivery rates and 80% or higher clinician adherence to recommendations. Descriptive statistics and generalized estimating equations were used for data analyses. Symptom assessment completion was 84% (95% CI=81-87%). Delivery of completed reports was 90% (95% CI=86-93%). Depression (36%), pain (30%), and fatigue (18%) occurred most frequently, followed by anxiety (11%) and dyspnea (6%). On average, overall recommendation adherence was 57% (95% CI=52-62%) and was not dependent on the number of recommendations (P=0.45). Adherence was higher for anxiety (66%; 95% CI=55-77%), depression (64%; 95% CI=56-71%), pain (62%; 95% CI=52-72%), and dyspnea (51%; 95% CI=38-64%) than for fatigue (38%; 95% CI=28-47%). The CDS systems, such as SAMI-L, have the potential to fill a gap in promoting evidence-based care. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  7. Clinical Decision Support Improves Initial Dosing and Monitoring of Tobramycin and Amikacin

    PubMed Central

    Cox, Zachary L.; Nelsen, Cori L.; Waitman, Lemuel R.; McCoy, Jacob A.; Peterson, Josh F.

    2010-01-01

    Purpose Clinical decision support (CDS) systems could be valuable tools in reducing aminoglycoside prescribing errors. We evaluated the impact of CDS on initial dosing, interval, and pharmacokinetic outcomes of amikacin and tobramycin therapy. Methods A complex CDS advisor to provide guidance on initial dosing and monitoring, using both traditional and extended interval dosing strategies, was integrated into computerized provider order entry (CPOE) and compared to a control group which featured close pharmacy monitoring of all aminoglycoside orders. A random sample of 118 patients from an academic, tertiary care medical center prescribed amikacin and tobramycin prior to advisor implementation was compared to 98 patients admitted following advisor implementation. Primary outcome was an initial dose within 10% of a dose calculated to be adherent to published dose guidelines. Secondary outcomes were a guideline-adherent interval, trough and peak concentrations in goal range, and incidence of nephrotoxicity. Results Of 216 patients studied, 97 were prescribed amikacin and 119 were prescribed tobramycin. The primary outcome of initial dosing consistent with guideline-based care increased from 40% in the pre-advisor arm to 80% in the post-advisor arm (p<0.001), with a number needed to treat of 3 patients to prevent one incorrect dose. Correct initial interval based on renal function also increased from 63% to 87% (p<0.001). The changes in initial dosing and interval resulted in an increase of trough concentrations in the goal range from 59% pre-advisor to 89% post-advisor implementation (p=0.0004). There was no significant difference in peak concentrations in goal range or incidence of nephrotoxicity (25% vs. 17%, p=0.2). Conclusion An advisor for aminoglycoside dosing and monitoring integrated into CPOE significantly improves initial dosing, selection of interval, and trough concentrations at goal compared to unassisted physician dosing. PMID:21411805

  8. UTD at TREC 2014: Query Expansion for Clinical Decision Support

    DTIC Science & Technology

    2014-11-01

    Description: A 62-year-old man sees a neurologist for progressive memory loss and jerking movements of the lower ex- tremities. Neurologic examination confirms...infiltration. Summary: 62-year-old man with progressive memory loss and in- voluntary leg movements. Brain MRI reveals cortical atrophy, and cortical...latent topics produced by the Latent Dirichlet Allocation (LDA) on the TREC-CDS corpus of scientific articles. The position of words “ loss ” and “ memory

  9. Measuring agreement between decision support reminders: the cloud vs. the local expert.

    PubMed

    Dixon, Brian Edward; Simonaitis, Linas; Perkins, Susan M; Wright, Adam; Middleton, Blackford

    2014-04-10

    A cloud-based clinical decision support system (CDSS) was implemented to remotely provide evidence-based guideline reminders in support of preventative health. Following implementation, we measured the agreement between preventive care reminders generated by an existing, local CDSS and the new, cloud-based CDSS operating on the same patient visit data. Electronic health record data for the same set of patients seen in primary care were sent to both the cloud-based web service and local CDSS. The clinical reminders returned by both services were captured for analysis. Cohen's Kappa coefficient was calculated to compare the two sets of reminders. Kappa statistics were further adjusted for prevalence and bias due to the potential effects of bias in the CDS logic and prevalence in the relative small sample of patients. The cloud-based CDSS generated 965 clinical reminders for 405 patient visits over 3 months. The local CDSS returned 889 reminders for the same patient visit data. When adjusted for prevalence and bias, observed agreement varied by reminder from 0.33 (95% CI 0.24 - 0.42) to 0.99 (95% CI 0.97 - 1.00) and demonstrated almost perfect agreement for 7 of the 11 reminders. Preventive care reminders delivered by two disparate CDS systems show substantial agreement. Subtle differences in rule logic and terminology mapping appear to account for much of the discordance. Cloud-based CDSS therefore show promise, opening the door for future development and implementation in support of health care providers with limited resources for knowledge management of complex logic and rules.

  10. Measuring agreement between decision support reminders: the cloud vs. the local expert

    PubMed Central

    2014-01-01

    Background A cloud-based clinical decision support system (CDSS) was implemented to remotely provide evidence-based guideline reminders in support of preventative health. Following implementation, we measured the agreement between preventive care reminders generated by an existing, local CDSS and the new, cloud-based CDSS operating on the same patient visit data. Methods Electronic health record data for the same set of patients seen in primary care were sent to both the cloud-based web service and local CDSS. The clinical reminders returned by both services were captured for analysis. Cohen’s Kappa coefficient was calculated to compare the two sets of reminders. Kappa statistics were further adjusted for prevalence and bias due to the potential effects of bias in the CDS logic and prevalence in the relative small sample of patients. Results The cloud-based CDSS generated 965 clinical reminders for 405 patient visits over 3 months. The local CDSS returned 889 reminders for the same patient visit data. When adjusted for prevalence and bias, observed agreement varied by reminder from 0.33 (95% CI 0.24 – 0.42) to 0.99 (95% CI 0.97 – 1.00) and demonstrated almost perfect agreement for 7 of the 11 reminders. Conclusions Preventive care reminders delivered by two disparate CDS systems show substantial agreement. Subtle differences in rule logic and terminology mapping appear to account for much of the discordance. Cloud-based CDSS therefore show promise, opening the door for future development and implementation in support of health care providers with limited resources for knowledge management of complex logic and rules. PMID:24720863

  11. Increasing Complexity in Rule-Based Clinical Decision Support: The Symptom Assessment and Management Intervention.

    PubMed

    Lobach, David F; Johns, Ellis B; Halpenny, Barbara; Saunders, Toni-Ann; Brzozowski, Jane; Del Fiol, Guilherme; Berry, Donna L; Braun, Ilana M; Finn, Kathleen; Wolfe, Joanne; Abrahm, Janet L; Cooley, Mary E

    2016-11-08

    Management of uncontrolled symptoms is an important component of quality cancer care. Clinical guidelines are available for optimal symptom management, but are not often integrated into the front lines of care. The use of clinical decision support (CDS) at the point-of-care is an innovative way to incorporate guideline-based symptom management into routine cancer care. The objective of this study was to develop and evaluate a rule-based CDS system to enable management of multiple symptoms in lung cancer patients at the point-of-care. This study was conducted in three phases involving a formative evaluation, a system evaluation, and a contextual evaluation of clinical use. In Phase 1, we conducted iterative usability testing of user interface prototypes with patients and health care providers (HCPs) in two thoracic oncology clinics. In Phase 2, we programmed complex algorithms derived from clinical practice guidelines into a rules engine that used Web services to communicate with the end-user application. Unit testing of algorithms was conducted using a stack-traversal tree-spanning methodology to identify all possible permutations of pathways through each algorithm, to validate accuracy. In Phase 3, we evaluated clinical use of the system among patients and HCPs in the two clinics via observations, structured interviews, and questionnaires. In Phase 1, 13 patients and 5 HCPs engaged in two rounds of formative testing, and suggested improvements leading to revisions until overall usability scores met a priori benchmarks. In Phase 2, symptom management algorithms contained between 29 and 1425 decision nodes, resulting in 19 to 3194 unique pathways per algorithm. Unit testing required 240 person-hours, and integration testing required 40 person-hours. In Phase 3, both patients and HCPs found the system usable and acceptable, and offered suggestions for improvements. A rule-based CDS system for complex symptom management was systematically developed and tested. The complexity of the algorithms required extensive development and innovative testing. The Web service-based approach allowed remote access to CDS knowledge, and could enable scaling and sharing of this knowledge to accelerate availability, and reduce duplication of effort. Patients and HCPs found the system to be usable and useful. ©David F Lobach, Ellis B Johns, Barbara Halpenny, Toni-Ann Saunders, Jane Brzozowski, Guilherme Del Fiol, Donna L Berry, Ilana M Braun, Kathleen Finn, Joanne Wolfe, Janet L Abrahm, Mary E Cooley. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 08.11.2016.

  12. Impact of Clinical Decision Support on Radiography for Acute Ankle Injuries: A Randomized Trial

    PubMed Central

    Tajmir, Shahein; Raja, Ali S.; Ip, Ivan K.; Andruchow, James; Silveira, Patricia; Smith, Stacy; Khorasani, Ramin

    2017-01-01

    Introduction While only 15–20% of patients with foot and ankle injuries presenting to urgent care centers have clinically significant fractures, most undergo radiography. We examined the impact of electronic point-of-care clinical decision support (CDS) on adherence to the Ottawa Ankle Rules (OAR), as well as use and yield of foot and ankle radiographs in patients with acute ankle injury. Methods We obtained institutional review board approval for this randomized controlled study performed April 18, 2012—December 15, 2013. All ordering providers credentialed at an urgent care affiliated with a quaternary care academic hospital were randomized to either receive or not receive CDS, based on the OAR and integrated into the physician order-entry system, with feedback at the time of imaging order. If the patient met OAR low-risk criteria, providers were advised against imaging and could either cancel the order or ignore the alert. We identified patients with foot and ankle complaints via ICD-9 billing codes and electronic health records and radiology reports reviewed for those who were eligible. Chi-square was used to compare adherence to the OAR (primary outcome), radiography utilization rate and radiography yield of foot and ankle imaging (secondary outcomes) between the intervention and control groups. Results Of 14,642 patients seen at urgent care during the study period, 613 (4.2%, representing 632 visits) presented with acute ankle injury and were eligible for application of the OAR; 374 (59.2%) of these were seen by control-group providers. In the intervention group, CDS adherence was higher for both ankle (239/258=92.6% vs. 231/374=61.8%, p=0.02) and foot radiography (209/258=81.0% vs. 238/374=63.6%; p<0.01). However, ankle radiography use was higher in the intervention group (166/258=64.3% vs. 183/374=48.9%; p<0.01), while foot radiography use (141/258=54.6% vs. 202/374=54.0%; p=0.95) was not. Radiography yield was also higher in the intervention group (26/307=8.5% vs. 18/385=4.7%; p=0.04). Conclusion Clinical decision support, previously demonstrated to improve guideline adherence for high-cost imaging, can also improve guideline adherence for radiography – as demonstrated by increased OAR adherence and increased imaging yield. PMID:28435501

  13. A long-term follow-up evaluation of electronic health record prescribing safety

    PubMed Central

    Abramson, Erika L; Malhotra, Sameer; Osorio, S Nena; Edwards, Alison; Cheriff, Adam; Cole, Curtis; Kaushal, Rainu

    2013-01-01

    Objective To be eligible for incentives through the Electronic Health Record (EHR) Incentive Program, many providers using older or locally developed EHRs will be transitioning to new, commercial EHRs. We previously evaluated prescribing errors made by providers in the first year following transition from a locally developed EHR with minimal prescribing clinical decision support (CDS) to a commercial EHR with robust CDS. Following system refinements, we conducted this study to assess the rates and types of errors 2 years after transition and determine the evolution of errors. Materials and methods We conducted a mixed methods cross-sectional case study of 16 physicians at an academic-affiliated ambulatory clinic from April to June 2010. We utilized standardized prescription and chart review to identify errors. Fourteen providers also participated in interviews. Results We analyzed 1905 prescriptions. The overall prescribing error rate was 3.8 per 100 prescriptions (95% CI 2.8 to 5.1). Error rates were significantly lower 2 years after transition (p<0.001 compared to pre-implementation, 12 weeks and 1 year after transition). Rates of near misses remained unchanged. Providers positively appreciated most system refinements, particularly reduced alert firing. Discussion Our study suggests that over time and with system refinements, use of a commercial EHR with advanced CDS can lead to low prescribing error rates, although more serious errors may require targeted interventions to eliminate them. Reducing alert firing frequency appears particularly important. Our results provide support for federal efforts promoting meaningful use of EHRs. Conclusions Ongoing error monitoring can allow CDS to be optimally tailored and help achieve maximal safety benefits. Clinical Trials Registration ClinicalTrials.gov, Identifier: NCT00603070. PMID:23578816

  14. The Impact of Electronic Knowledge-Based Nursing Content and Decision-Support on Nursing-Sensitive Patient Outcomes

    DTIC Science & Technology

    2016-02-01

    other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a ...Based Nursing (KBN) innovation, a customized design featuring actionable EB recommendations embedded into policy and the content and CDS tools in the...will have a positive effect on nursing knowledge, use of evidence-based practices, and the achievement of nurse-sensitive patient outcomes at

  15. NASA's Climate Data Services Initiative

    NASA Astrophysics Data System (ADS)

    McInerney, M.; Duffy, D.; Schnase, J. L.; Webster, W. P.

    2013-12-01

    Our understanding of the Earth's processes is based on a combination of observational data records and mathematical models. The size of NASA's space-based observational data sets is growing dramatically as new missions come online. However a potentially bigger data challenge is posed by the work of climate scientists, whose models are regularly producing data sets of hundreds of terabytes or more. It is important to understand that the 'Big Data' challenge of climate science cannot be solved with a single technological approach or an ad hoc assemblage of technologies. It will require a multi-faceted, well-integrated suite of capabilities that include cloud computing, large-scale compute-storage systems, high-performance analytics, scalable data management, and advanced deployment mechanisms in addition to the existing, well-established array of mature information technologies. It will also require a coherent organizational effort that is able to focus on the specific and sometimes unique requirements of climate science. Given that it is the knowledge that is gained from data that is of ultimate benefit to society, data publication and data analytics will play a particularly important role. In an effort to accelerate scientific discovery and innovation through broader use of climate data, NASA Goddard Space Flight Center's Office of Computational and Information Sciences and Technology has embarked on a determined effort to build a comprehensive, integrated data publication and analysis capability for climate science. The Climate Data Services (CDS) Initiative integrates people, expertise, and technology into a highly-focused, next-generation, one-stop climate science information service. The CDS Initiative is providing the organizational framework, processes, and protocols needed to deploy existing information technologies quickly using a combination of enterprise-level services and an expanding array of cloud services. Crucial to its effectiveness, the CDS Initiative is developing the technical expertise to move new information technologies from R&D into operational use. This combination enables full, end-to-end support for climate data publishing and data analytics, and affords the flexibility required to meet future and unanticipated needs. Current science efforts being supported by the CDS Initiative include IPPC, OBS4MIP, ANA4MIPS, MERRA II, National Climate Assessment, the Ocean Data Assimilation project, NASA Earth Exchange (NEX), and the RECOVER Burned Area Emergency Response decision support system. Service offerings include an integrated suite of classic technologies (FTP, LAS, THREDDS, ESGF, GRaD-DODS, OPeNDAP, WMS, ArcGIS Server), emerging technologies (iRODS, UVCDAT), and advanced technologies (MERRA Analytic Services, MapReduce, Ontology Services, and the CDS API). This poster will describe the CDS Initiative, provide details about the Initiative's advanced offerings, and layout the CDS Initiative's deployment roadmap.

  16. Resources and rewards for clerkship directors: how surgery compares.

    PubMed

    Ephgrave, Kimberly; Ferguson, Kristi; Shaaban, Aimen; Hoshi, Hisakazu

    2010-01-01

    Clerkship directors (CDs) are key educators and active clinicians. In 2003, the Alliance for Clinical Education published standards for CD resources and responsibilities, but how reality compares is unknown. Representatives from each core clinical disciplines' CD organizations created an electronic survey that CDs received in 2006-2007. More than 500 CDs responded, including 71 surgeons. Surgeons reported spending approximately 27% of professional time on education. Most have codirectors, so total CD effort approximates the greater than 50% Alliance for Clinical Education guidelines. No disciplines' CDs have more than one support staff as recommended. Surgeons have the least clinic time, but the most inpatient weeks and many publications. Surgery CD concerns are curricula and simulation; few believe being a CD impairs academic advancement and more than 95% believe it enhances work satisfaction. Surgery CDs are clinically active and academically productive. Although few surgery CDs have the recommended support staff, more than 95% report being a CD enhances work satisfaction.

  17. Sharing clinical decisions for multimorbidity case management using social network and open-source tools.

    PubMed

    Martínez-García, Alicia; Moreno-Conde, Alberto; Jódar-Sánchez, Francisco; Leal, Sandra; Parra, Carlos

    2013-12-01

    Social networks applied through Web 2.0 tools have gained importance in health domain, because they produce improvements on the communication and coordination capabilities among health professionals. This is highly relevant for multimorbidity patients care because there is a large number of health professionals in charge of patient care, and this requires to obtain clinical consensus in their decisions. Our objective is to develop a tool for collaborative work among health professionals for multimorbidity patient care. We describe the architecture to incorporate decision support functionalities in a social network tool to enable the adoption of shared decisions among health professionals from different care levels. As part of the first stage of the project, this paper describes the results obtained in a pilot study about acceptance and use of the social network component in our healthcare setting. At Virgen del Rocío University Hospital we have designed and developed the Shared Care Platform (SCP) to provide support in the continuity of care for multimorbidity patients. The SCP has two consecutively developed components: social network component, called Clinical Wall, and Clinical Decision Support (CDS) system. The Clinical Wall contains a record where health professionals are able to debate and define shared decisions. We conducted a pilot study to assess the use and acceptance of the SCP by healthcare professionals through questionnaire based on the theory of the Technology Acceptance Model. In March 2012 we released and deployed the SCP, but only with the social network component. The pilot project lasted 6 months in the hospital and 2 primary care centers. From March to September 2012 we created 16 records in the Clinical Wall, all with a high priority. A total of 10 professionals took part in the exchange of messages: 3 internists and 7 general practitioners generated 33 messages. 12 of the 16 record (75%) were answered by the destination health professionals. The professionals valued positively all the items in the questionnaire. As part of the SCP, opensource tools for CDS will be incorporated to provide recommendations for medication and problem interactions, as well as to calculate indexes or scales from validated questionnaires. They will receive the patient summary information provided by the regional Electronic Health Record system through a web service with the information defined according to the virtual Medical Record specification. Clinical Wall has been developed to allow communication and coordination between the healthcare professionals involved in multimorbidity patient care. Agreed decisions were about coordination for appointment changing, patient conditions, diagnosis tests, and prescription changes and renewal. The application of interoperability standards and open source software can bridge the gap between knowledge and clinical practice, while enabling interoperability and scalability. Open source with the social network encourages adoption and facilitates collaboration. Although the results obtained for use indicators are still not as high as it was expected, based on the promising results obtained in the acceptance questionnaire of SMP, we expect that the new CDS tools will increase the use by the health professionals. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. A service oriented approach for guidelines-based clinical decision support using BPMN.

    PubMed

    Rodriguez-Loya, Salvador; Aziz, Ayesha; Chatwin, Chris

    2014-01-01

    Evidence-based medical practice requires that clinical guidelines need to be documented in such a way that they represent a clinical workflow in its most accessible form. In order to optimize clinical processes to improve clinical outcomes, we propose a Service Oriented Architecture (SOA) based approach for implementing clinical guidelines that can be accessed from an Electronic Health Record (EHR) application with a Web Services enabled communication mechanism with the Enterprise Service Bus. We have used Business Process Modelling Notation (BPMN) for modelling and presenting the clinical pathway in the form of a workflow. The aim of this study is to produce spontaneous alerts in the healthcare workflow in the diagnosis of Chronic Obstructive Pulmonary Disease (COPD). The use of BPMN as a tool to automate clinical guidelines has not been previously employed for providing Clinical Decision Support (CDS).

  19. Retrospective checking of compliance with practice guidelines for acute stroke care: a novel experiment using openEHR’s Guideline Definition Language

    PubMed Central

    2014-01-01

    Background Providing scalable clinical decision support (CDS) across institutions that use different electronic health record (EHR) systems has been a challenge for medical informatics researchers. The lack of commonly shared EHR models and terminology bindings has been recognised as a major barrier to sharing CDS content among different organisations. The openEHR Guideline Definition Language (GDL) expresses CDS content based on openEHR archetypes and can support any clinical terminologies or natural languages. Our aim was to explore in an experimental setting the practicability of GDL and its underlying archetype formalism. A further aim was to report on the artefacts produced by this new technological approach in this particular experiment. We modelled and automatically executed compliance checking rules from clinical practice guidelines for acute stroke care. Methods We extracted rules from the European clinical practice guidelines as well as from treatment contraindications for acute stroke care and represented them using GDL. Then we executed the rules retrospectively on 49 mock patient cases to check the cases’ compliance with the guidelines, and manually validated the execution results. We used openEHR archetypes, GDL rules, the openEHR reference information model, reference terminologies and the Data Archetype Definition Language. We utilised the open-sourced GDL Editor for authoring GDL rules, the international archetype repository for reusing archetypes, the open-sourced Ocean Archetype Editor for authoring or modifying archetypes and the CDS Workbench for executing GDL rules on patient data. Results We successfully represented clinical rules about 14 out of 19 contraindications for thrombolysis and other aspects of acute stroke care with 80 GDL rules. These rules are based on 14 reused international archetypes (one of which was modified), 2 newly created archetypes and 51 terminology bindings (to three terminologies). Our manual compliance checks for 49 mock patients were a complete match versus the automated compliance results. Conclusions Shareable guideline knowledge for use in automated retrospective checking of guideline compliance may be achievable using GDL. Whether the same GDL rules can be used for at-the-point-of-care CDS remains unknown. PMID:24886468

  20. An information management system for patients with tuberculosis: usability assessment with end-users.

    PubMed

    Darby, Jonathan; Black, Jim; Morrison, David; Buising, Kirsty

    2012-01-01

    Information systems with clinical decision support (CDS) offer great potential to assist the co-ordination of patients with chronic diseases and to improve patient care. Despite this, few have entered routine clinical use. Tuberculosis (TB) is an infection of public health importance. It has complex interactions with many comorbid conditions, requires close supervised care and prolonged treatment for effective cure. These features make it suitable for use with an information management system with CDS features. In close consultation with key stakeholders, a clinical application was developed for the management of TB patients in Victoria. A formal usability assessment using semi-structured case-scenario based exercises was performed. Subjects were 12 individuals closely involved in the care of TB patients, including Infectious Diseases and Respiratory Physicians, and Public Health Nurses. Two researchers conducted the sessions, independently analysed responses and discrepancies compared to the voice record for validity. Despite varied computer experience, responses were positive regarding user interface and content. Data location was not always intuitive, however this improved with familiarity of the program. Decision support was considered valuable, with useful suggestions for expansion of these features. Automated reporting for correspondence and notification to the Health Department were felt worth the initial investment in data entry. An important workflow-based issue regarding dismissal of alerts and several errors were detected. Usability assessment validated many design elements of the system, provided a unique insight into workflow issues faced by users and hopefully will impact on its ultimate clinical utility.

  1. Decision support from local data: creating adaptive order menus from past clinician behavior.

    PubMed

    Klann, Jeffrey G; Szolovits, Peter; Downs, Stephen M; Schadow, Gunther

    2014-04-01

    Reducing care variability through guidelines has significantly benefited patients. Nonetheless, guideline-based Clinical Decision Support (CDS) systems are not widely implemented or used, are frequently out-of-date, and cannot address complex care for which guidelines do not exist. Here, we develop and evaluate a complementary approach - using Bayesian Network (BN) learning to generate adaptive, context-specific treatment menus based on local order-entry data. These menus can be used as a draft for expert review, in order to minimize development time for local decision support content. This is in keeping with the vision outlined in the US Health Information Technology Strategic Plan, which describes a healthcare system that learns from itself. We used the Greedy Equivalence Search algorithm to learn four 50-node domain-specific BNs from 11,344 encounters: abdominal pain in the emergency department, inpatient pregnancy, hypertension in the Urgent Visit Clinic, and altered mental state in the intensive care unit. We developed a system to produce situation-specific, rank-ordered treatment menus from these networks. We evaluated this system with a hospital-simulation methodology and computed Area Under the Receiver-Operator Curve (AUC) and average menu position at time of selection. We also compared this system with a similar association-rule-mining approach. A short order menu on average contained the next order (weighted average length 3.91-5.83 items). Overall predictive ability was good: average AUC above 0.9 for 25% of order types and overall average AUC .714-.844 (depending on domain). However, AUC had high variance (.50-.99). Higher AUC correlated with tighter clusters and more connections in the graphs, indicating importance of appropriate contextual data. Comparison with an Association Rule Mining approach showed similar performance for only the most common orders with dramatic divergence as orders are less frequent. This study demonstrates that local clinical knowledge can be extracted from treatment data for decision support. This approach is appealing because: it reflects local standards; it uses data already being captured; and it produces human-readable treatment-diagnosis networks that could be curated by a human expert to reduce workload in developing localized CDS content. The BN methodology captured transitive associations and co-varying relationships, which existing approaches do not. It also performs better as orders become less frequent and require more context. This system is a step forward in harnessing local, empirical data to enhance decision support. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Decision Support from Local Data: Creating Adaptive Order Menus from Past Clinician Behavior

    PubMed Central

    Klann, Jeffrey G.; Szolovits, Peter; Downs, Stephen; Schadow, Gunther

    2014-01-01

    Objective Reducing care variability through guidelines has significantly benefited patients. Nonetheless, guideline-based clinical decision support (CDS) systems are not widely implemented or used, are frequently out-of-date, and cannot address complex care for which guidelines do not exist. Here, we develop and evaluate a complementary approach - using Bayesian network (BN) learning to generate adaptive, context-specific treatment menus based on local order-entry data. These menus can be used as a draft for expert review, in order to minimize development time for local decision support content. This is in keeping with the vision outlined in the US Health Information Technology Strategic Plan, which describes a healthcare system that learns from itself. Materials and Methods We used the Greedy Equivalence Search algorithm to learn four 50-node domain-specific BNs from 11,344 encounters: abdominal pain in the emergency department, inpatient pregnancy, hypertension in the urgent visit clinic, and altered mental state in the intensive care unit. We developed a system to produce situation-specific, rank-ordered treatment menus from these networks. We evaluated this system with a hospital-simulation methodology and computed Area Under the Receiver-Operator Curve (AUC) and average menu position at time of selection. We also compared this system with a similar association-rule-mining approach. Results A short order menu on average contained the next order (weighted average length 3.91–5.83 items). Overall predictive ability was good: average AUC above 0.9 for 25% of order types and overall average AUC .714–.844 (depending on domain). However, AUC had high variance (.50–.99). Higher AUC correlated with tighter clusters and more connections in the graphs, indicating importance of appropriate contextual data. Comparison with an association rule mining approach showed similar performance for only the most common orders with dramatic divergence as orders are less frequent. Discussion and Conclusion This study demonstrates that local clinical knowledge can be extracted from treatment data for decision support. This approach is appealing because: it reflects local standards; it uses data already being captured; and it produces human-readable treatment-diagnosis networks that could be curated by a human expert to reduce workload in developing localized CDS content. The BN methodology captured transitive associations and co-varying relationships, which existing approaches do not. It also performs better as orders become less frequent and require more context. This system is a step forward in harnessing local, empirical data to enhance decision support. PMID:24355978

  3. Clinical Assistant Diagnosis for Electronic Medical Record Based on Convolutional Neural Network.

    PubMed

    Yang, Zhongliang; Huang, Yongfeng; Jiang, Yiran; Sun, Yuxi; Zhang, Yu-Jin; Luo, Pengcheng

    2018-04-20

    Automatically extracting useful information from electronic medical records along with conducting disease diagnoses is a promising task for both clinical decision support(CDS) and neural language processing(NLP). Most of the existing systems are based on artificially constructed knowledge bases, and then auxiliary diagnosis is done by rule matching. In this study, we present a clinical intelligent decision approach based on Convolutional Neural Networks(CNN), which can automatically extract high-level semantic information of electronic medical records and then perform automatic diagnosis without artificial construction of rules or knowledge bases. We use collected 18,590 copies of the real-world clinical electronic medical records to train and test the proposed model. Experimental results show that the proposed model can achieve 98.67% accuracy and 96.02% recall, which strongly supports that using convolutional neural network to automatically learn high-level semantic features of electronic medical records and then conduct assist diagnosis is feasible and effective.

  4. ADESSA: A Real-Time Decision Support Service for Delivery of Semantically Coded Adverse Drug Event Data

    PubMed Central

    Duke, Jon D.; Friedlin, Jeff

    2010-01-01

    Evaluating medications for potential adverse events is a time-consuming process, typically involving manual lookup of information by physicians. This process can be expedited by CDS systems that support dynamic retrieval and filtering of adverse drug events (ADE’s), but such systems require a source of semantically-coded ADE data. We created a two-component system that addresses this need. First we created a natural language processing application which extracts adverse events from Structured Product Labels and generates a standardized ADE knowledge base. We then built a decision support service that consumes a Continuity of Care Document and returns a list of patient-specific ADE’s. Our database currently contains 534,125 ADE’s from 5602 product labels. An NLP evaluation of 9529 ADE’s showed recall of 93% and precision of 95%. On a trial set of 30 CCD’s, the system provided adverse event data for 88% of drugs and returned these results in an average of 620ms. PMID:21346964

  5. Architecture Design of Healthcare Software-as-a-Service Platform for Cloud-Based Clinical Decision Support Service.

    PubMed

    Oh, Sungyoung; Cha, Jieun; Ji, Myungkyu; Kang, Hyekyung; Kim, Seok; Heo, Eunyoung; Han, Jong Soo; Kang, Hyunggoo; Chae, Hoseok; Hwang, Hee; Yoo, Sooyoung

    2015-04-01

    To design a cloud computing-based Healthcare Software-as-a-Service (SaaS) Platform (HSP) for delivering healthcare information services with low cost, high clinical value, and high usability. We analyzed the architecture requirements of an HSP, including the interface, business services, cloud SaaS, quality attributes, privacy and security, and multi-lingual capacity. For cloud-based SaaS services, we focused on Clinical Decision Service (CDS) content services, basic functional services, and mobile services. Microsoft's Azure cloud computing for Infrastructure-as-a-Service (IaaS) and Platform-as-a-Service (PaaS) was used. The functional and software views of an HSP were designed in a layered architecture. External systems can be interfaced with the HSP using SOAP and REST/JSON. The multi-tenancy model of the HSP was designed as a shared database, with a separate schema for each tenant through a single application, although healthcare data can be physically located on a cloud or in a hospital, depending on regulations. The CDS services were categorized into rule-based services for medications, alert registration services, and knowledge services. We expect that cloud-based HSPs will allow small and mid-sized hospitals, in addition to large-sized hospitals, to adopt information infrastructures and health information technology with low system operation and maintenance costs.

  6. A Clinician-Centered Evaluation of the Usability of AHLTA and Automated Clinical Practice Guidelines at TAMC

    DTIC Science & Technology

    2011-03-31

    evidence based medicine into clinical practice. It will decrease costs and enable multiple stakeholders to work in an open content/source environment to exchange clinical content, develop and test technology and explore processes in applied CDS. Design: Comparative study between the KMR infrastructure and capabilities developed as an open source, vendor agnostic solution for aCPG execution within AHLTA and the current DoD/MHS standard evaluating: H1: An open source, open standard KMR and Clinical Decision Support Engine can enable organizations to share domain

  7. Knowledge Integration and Use-Case Analysis for a Customized Drug-Drug Interaction CDS Service

    NASA Astrophysics Data System (ADS)

    Kam, Hye Jin; Park, Man Young; Kim, Woojae; Yoon, Duk Yong; Ahn, Eun Kyoung; Park, Rae Woong

    Clinical decision support systems (CDSSs) are thought to reduce adverse drug events (ADEs) by monitoring drug-drug interactions(DDIs). However, clinically improper or excessive alerts can result in high alert overrides. A tailored CDS service, which is appropriate for clinicians and their ordering situations, is required to increase alert acceptance. In this study, we conducted a 12-week pilot project adopting a tailed CDSS at an emergency department. The new CDSS was conducted via a stepwise integration of additional new rules. The alert status with changes in acceptance rate was analyzed. The most frequent DDI alerts were related to prescriptions of anti-inflammatory drugs. The percentages of alert overrides for each stage were 98.0%, 96.0%, 96.9%, and 98.1%, respectively. 91.5% of overridden alerts were related to discharge medications. To reduce the potential hazards of ADEs, the development of an effective customized DDI CDSS is required, via in-depth analysis on alert patterns and overridden reasons.

  8. “Reducing unnecessary testing in a CPOE system through implementation of a targeted CDS intervention”

    PubMed Central

    2013-01-01

    Background We describe and evaluate the development and use of a Clinical Decision Support (CDS) intervention; an alert, in response to an identified medical error of overuse of a diagnostic laboratory test in a Computerized Physician Order Entry (CPOE) system. CPOE with embedded CDS has been shown to improve quality of care and reduce medical errors. CPOE can also improve resource utilization through more appropriate use of laboratory tests and diagnostic studies. Observational studies are necessary in order to understand how these technologies can be successfully employed by healthcare providers. Methods The error was identified by the Test Utilization Committee (TUC) in September, 2008 when they noticed critical care patients were being tested daily, and sometimes twice daily, for B-Type Natriuretic Peptide (BNP). Repeat and/or serial BNP testing is inappropriate for guiding the management of heart failure and may be clinically misleading. The CDS intervention consists of an expert rule that searches the system for a BNP lab value on the patient. If there is a value and the value is within the current hospital stay, an advisory is displayed to the ordering clinician. In order to isolate the impact of this intervention on unnecessary BNP testing we applied multiple regression analysis to the sample of 41,306 patient admissions with at least one BNP test at LVHN between January, 2008 and September, 2011. Results Our regression results suggest the CDS intervention reduced BNP orders by 21% relative to the mean. The financial impact of the rule was also significant. Multiplying by the direct supply cost of $28.04 per test, the intervention saved approximately $92,000 per year. Conclusions The use of alerts has great positive potential to improve care, but should be used judiciously and in the appropriate environment. While these savings may not be generalizable to other interventions, the experience at LVHN suggests that appropriately designed and carefully implemented CDS interventions can have a substantial impact on the efficiency of care provision. PMID:23566021

  9. Efficacy of education followed by computerized provider order entry with clinician decision support to reduce red blood cell utilization.

    PubMed

    Zuckerberg, Gabriel S; Scott, Andrew V; Wasey, Jack O; Wick, Elizabeth C; Pawlik, Timothy M; Ness, Paul M; Patel, Nishant D; Resar, Linda M S; Frank, Steven M

    2015-07-01

    Two necessary components of a patient blood management program are education regarding evidence-based transfusion guidelines and computerized provider order entry (CPOE) with clinician decision support (CDS). This study examines changes in red blood cell (RBC) utilization associated with each of these two interventions. We reviewed 5 years of blood utilization data (2009-2013) for 70,118 surgical patients from 10 different specialty services at a tertiary care academic medical center. Three distinct periods were compared: 1) before blood management, 2) education alone, and 3) education plus CPOE. Changes in RBC unit utilization were assessed over the three periods stratified by surgical service. Cost savings were estimated based on RBC acquisition costs. For all surgical services combined, RBC utilization decreased by 16.4% with education alone (p = 0.001) and then changed very little (2.5% increase) after subsequent addition of CPOE (p = 0.64). When we compared the period of education plus CPOE to the pre-blood management period, the overall decrease was 14.3% (p = 0.008; 2102 fewer RBC units/year, or a cost avoidance of $462,440/year). Services with the highest massive transfusion rates (≥10 RBC units) exhibited the least reduction in RBC utilization. Adding CPOE with CDS after a successful education effort to promote evidence-based transfusion practice did not further reduce RBC utilization. These findings suggest that education is an important and effective component of a patient blood management program and that CPOE algorithms may serve to maintain compliance with evidence-based transfusion guidelines. © 2015 AABB.

  10. A study of diverse clinical decision support rule authoring environments and requirements for integration

    PubMed Central

    2012-01-01

    Background Efficient rule authoring tools are critical to allow clinical Knowledge Engineers (KEs), Software Engineers (SEs), and Subject Matter Experts (SMEs) to convert medical knowledge into machine executable clinical decision support rules. The goal of this analysis was to identify the critical success factors and challenges of a fully functioning Rule Authoring Environment (RAE) in order to define requirements for a scalable, comprehensive tool to manage enterprise level rules. Methods The authors evaluated RAEs in active use across Partners Healthcare, including enterprise wide, ambulatory only, and system specific tools, with a focus on rule editors for reminder and medication rules. We conducted meetings with users of these RAEs to discuss their general experience and perceived advantages and limitations of these tools. Results While the overall rule authoring process is similar across the 10 separate RAEs, the system capabilities and architecture vary widely. Most current RAEs limit the ability of the clinical decision support (CDS) interventions to be standardized, sharable, interoperable, and extensible. No existing system meets all requirements defined by knowledge management users. Conclusions A successful, scalable, integrated rule authoring environment will need to support a number of key requirements and functions in the areas of knowledge representation, metadata, terminology, authoring collaboration, user interface, integration with electronic health record (EHR) systems, testing, and reporting. PMID:23145874

  11. Effects of staff training and electronic event monitoring on long-term adherence to lung-protective ventilation recommendations.

    PubMed

    Castellanos, Ixchel; Martin, Marcus; Kraus, Stefan; Bürkle, Thomas; Prokosch, Hans-Ulrich; Schüttler, Jürgen; Toddenroth, Dennis

    2018-02-01

    To investigate long-term effects of staff training and electronic clinical decision support (CDS) on adherence to lung-protective ventilation recommendations. In 2012, group instructions and workshops at two surgical intensive care units (ICUs) started, focusing on standardized protocols for mechanical ventilation and volutrauma prevention. Subsequently implemented CDS functions continuously monitor ventilation parameters, and from 2015 triggered graphical notifications when tidal volume (V T ) violated individual thresholds. To estimate the effects of these educational and technical interventions, we retrospectively analyzed nine years of V T records from routine care. As outcome measures, we calculated relative frequencies of settings that conform to recommendations, case-specific mean excess V T , and total ICU survival. Assessing 571,478 V T records from 10,241 ICU cases indicated that adherence during pressure-controlled ventilation improved significantly after both interventions; the share of conforming V T records increased from 61.6% to 83.0% and then 86.0%. Despite increasing case severity, ICU survival remained nearly constant over time. Staff training effectively improves adherence to lung-protective ventilation strategies. The observed CDS effect seemed less pronounced, although it can easily be adapted to new recommendations. Both interventions, which futures studies could deploy in combination, promise to improve the precision of mechanical ventilation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Automated acute kidney injury alerts.

    PubMed

    Kashani, Kianoush B

    2018-05-02

    Acute kidney injury (AKI) is one of the most common and probably one of the more consequential complications of critical illnesses. Recent information indicates that it is at least partially preventable; however, progress in its prevention, management, and treatment has been hindered by the scarcity of knowledge for effective interventions, inconsistencies in clinical practices, late identification of patients at risk for or with AKI, and limitations of access to best practices for prevention and management of AKI. Growing use of electronic health records has provided a platform for computer science to engage in data mining and processing, not only for early detection of AKI but also for the development of risk-stratification strategies and computer clinical decision-support (CDS) systems. Despite promising perspectives, the literature regarding the impact of AKI electronic alerts and CDS systems has been conflicting. Some studies have reported improvement in care processes and patient outcomes, whereas others have shown no effect on clinical outcomes and yet demonstrated an increase in the use of resources. These discrepancies are thought to be due to multiple factors that may be related to technology, human factors, modes of delivery of information to clinical providers, and level of expectations regarding the impact on patient outcomes. This review appraises the current body of knowledge and provides some outlines regarding research into and clinical aspects of CDS systems for AKI. Copyright © 2018 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  13. EMR-based medical knowledge representation and inference via Markov random fields and distributed representation learning.

    PubMed

    Zhao, Chao; Jiang, Jingchi; Guan, Yi; Guo, Xitong; He, Bin

    2018-05-01

    Electronic medical records (EMRs) contain medical knowledge that can be used for clinical decision support (CDS). Our objective is to develop a general system that can extract and represent knowledge contained in EMRs to support three CDS tasks-test recommendation, initial diagnosis, and treatment plan recommendation-given the condition of a patient. We extracted four kinds of medical entities from records and constructed an EMR-based medical knowledge network (EMKN), in which nodes are entities and edges reflect their co-occurrence in a record. Three bipartite subgraphs (bigraphs) were extracted from the EMKN, one to support each task. One part of the bigraph was the given condition (e.g., symptoms), and the other was the condition to be inferred (e.g., diseases). Each bigraph was regarded as a Markov random field (MRF) to support the inference. We proposed three graph-based energy functions and three likelihood-based energy functions. Two of these functions are based on knowledge representation learning and can provide distributed representations of medical entities. Two EMR datasets and three metrics were utilized to evaluate the performance. As a whole, the evaluation results indicate that the proposed system outperformed the baseline methods. The distributed representation of medical entities does reflect similarity relationships with respect to knowledge level. Combining EMKN and MRF is an effective approach for general medical knowledge representation and inference. Different tasks, however, require individually designed energy functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Test Telemetry And Command System (TTACS)

    NASA Technical Reports Server (NTRS)

    Fogel, Alvin J.

    1994-01-01

    The Jet Propulsion Laboratory has developed a multimission Test Telemetry and Command System (TTACS) which provides a multimission telemetry and command data system in a spacecraft test environment. TTACS reuses, in the spacecraft test environment, components of the same data system used for flight operations; no new software is developed for the spacecraft test environment. Additionally, the TTACS is transportable to any spacecraft test site, including the launch site. The TTACS is currently operational in the Galileo spacecraft testbed; it is also being provided to support the Cassini and Mars Surveyor Program projects. Minimal personnel data system training is required in the transition from pre-launch spacecraft test to post-launch flight operations since test personnel are already familiar with the data system's operation. Additionally, data system components, e.g. data display, can be reused to support spacecraft software development; and the same data system components will again be reused during the spacecraft integration and system test phases. TTACS usage also results in early availability of spacecraft data to data system development and, as a result, early data system development feedback to spacecraft system developers. The TTACS consists of a multimission spacecraft support equipment interface and components of the multimission telemetry and command software adapted for a specific project. The TTACS interfaces to the spacecraft, e.g., Command Data System (CDS), support equipment. The TTACS telemetry interface to the CDS support equipment performs serial (RS-422)-to-ethernet conversion at rates between 1 bps and 1 mbps, telemetry data blocking and header generation, guaranteed data transmission to the telemetry data system, and graphical downlink routing summary and control. The TTACS command interface to the CDS support equipment is nominally a command file transferred in non-real-time via ethernet. The CDS support equipment is responsible for metering the commands to the CDS; additionally for Galileo, TTACS includes a real-time-interface to the CDS support equipment. The TTACS provides the basic functionality of the multimission telemetry and command data system used during flight operations. TTACS telemetry capabilities include frame synchronization, Reed-Solomon decoding, packet extraction and channelization, and data storage/query. Multimission data display capabilities are also available. TTACS command capabilities include command generation verification, and storage.

  15. A Pediatric Intensive Care Unit Bedside Computer Clinical Decision Support Protocol for Hyperglycemia Is Feasible, Safe and Offers Advantages

    PubMed Central

    Lanspa, Michael J.; Wilson, Emily L.; Sward, Katherine A.; Jephson, Al; Larsen, Gitte Y.; Morris, Alan H.

    2017-01-01

    Abstract Background: Computer clinical decision support (CDS) systems are uncommon in the pediatric intensive care unit (PICU), despite evidence suggesting they improve outcomes in adult ICUs. We reasoned that a bedside CDS protocol for intravenous insulin titration, eProtocol-insulin, would be feasible and safe in critically ill children. Methods: We retrospectively reviewed data from non-diabetic children admitted to the PICU with blood glucose (BG) ≥140 mg/dL who were managed with intravenous insulin by either unaided clinician titration or eProtocol-insulin. Primary outcomes were BG measurements in target range (80–110 mg/dL) and severe hypoglycemia (BG ≤40 mg/dL); secondary outcomes were 60-day mortality and PICU length of stay. We assessed bedside nurse satisfaction with the eProtocol-insulin protocol by using a 5-point Likert scale and measured clinician compliance with eProtocol-insulin recommendations. Results: Over 5 years, 69 children were titrated with eProtocol-insulin versus 104 by unaided clinicians. eProtocol-insulin achieved target range more frequently than clinician titration (41% vs. 32%, P < 0.001). Severe hypoglycemia was uncommon in both groups (4.3% of patients in eProtocol-insulin, 8.7% in clinician titration, P = 0.37). There were no differences in mean time to BG target or median BG between the groups. Mortality was 23% in both groups. Clinician compliance with eProtocol-insulin recommendations was 89%. Nurses believed that eProtocol-insulin was easy to understand and safer than clinician titration. Conclusions: eProtocol-insulin is safe for titration of intravenous insulin in critically ill children. Clinical research protocols and quality improvement initiatives aimed at optimizing BG control should utilize detailed computer protocols that enable replicable clinician decisions. PMID:28248127

  16. Cooperative Data Sharing: Simple Support for Clusters of SMP Nodes

    NASA Technical Reports Server (NTRS)

    DiNucci, David C.; Balley, David H. (Technical Monitor)

    1997-01-01

    Libraries like PVM and MPI send typed messages to allow for heterogeneous cluster computing. Lower-level libraries, such as GAM, provide more efficient access to communication by removing the need to copy messages between the interface and user space in some cases. still lower-level interfaces, such as UNET, get right down to the hardware level to provide maximum performance. However, these are all still interfaces for passing messages from one process to another, and have limited utility in a shared-memory environment, due primarily to the fact that message passing is just another term for copying. This drawback is made more pertinent by today's hybrid architectures (e.g. clusters of SMPs), where it is difficult to know beforehand whether two communicating processes will share memory. As a result, even portable language tools (like HPF compilers) must either map all interprocess communication, into message passing with the accompanying performance degradation in shared memory environments, or they must check each communication at run-time and implement the shared-memory case separately for efficiency. Cooperative Data Sharing (CDS) is a single user-level API which abstracts all communication between processes into the sharing and access coordination of memory regions, in a model which might be described as "distributed shared messages" or "large-grain distributed shared memory". As a result, the user programs to a simple latency-tolerant abstract communication specification which can be mapped efficiently to either a shared-memory or message-passing based run-time system, depending upon the available architecture. Unlike some distributed shared memory interfaces, the user still has complete control over the assignment of data to processors, the forwarding of data to its next likely destination, and the queuing of data until it is needed, so even the relatively high latency present in clusters can be accomodated. CDS does not require special use of an MMU, which can add overhead to some DSM systems, and does not require an SPMD programming model. unlike some message-passing interfaces, CDS allows the user to implement efficient demand-driven applications where processes must "fight" over data, and does not perform copying if processes share memory and do not attempt concurrent writes. CDS also supports heterogeneous computing, dynamic process creation, handlers, and a very simple thread-arbitration mechanism. Additional support for array subsections is currently being considered. The CDS1 API, which forms the kernel of CDS, is built primarily upon only 2 communication primitives, one process initiation primitive, and some data translation (and marshalling) routines, memory allocation routines, and priority control routines. The entire current collection of 28 routines provides enough functionality to implement most (or all) of MPI 1 and 2, which has a much larger interface consisting of hundreds of routines. still, the API is small enough to consider integrating into standard os interfaces for handling inter-process communication in a network-independent way. This approach would also help to solve many of the problems plaguing other higher-level standards such as MPI and PVM which must, in some cases, "play OS" to adequately address progress and process control issues. The CDS2 API, a higher level of interface roughly equivalent in functionality to MPI and to be built entirely upon CDS1, is still being designed. It is intended to add support for the equivalent of communicators, reduction and other collective operations, process topologies, additional support for process creation, and some automatic memory management. CDS2 will not exactly match MPI, because the copy-free semantics of communication from CDS1 will be supported. CDS2 application programs will be free to carefully also use CDS1. CDS1 has been implemented on networks of workstations running unmodified Unix-based operating systems, using UDP/IP and vendor-supplied high- performance locks. Although its inter-node performance is currently unimpressive due to rudimentary implementation technique, it even now outperforms highly-optimized MPI implementation on intra-node communication due to its support for non-copy communication. The similarity of the CDS1 architecture to that of other projects such as UNET and TRAP suggests that the inter-node performance can be increased significantly to surpass MPI or PVM, and it may be possible to migrate some of its functionality to communication controllers.

  17. Architecture Design of Healthcare Software-as-a-Service Platform for Cloud-Based Clinical Decision Support Service

    PubMed Central

    Oh, Sungyoung; Cha, Jieun; Ji, Myungkyu; Kang, Hyekyung; Kim, Seok; Heo, Eunyoung; Han, Jong Soo; Kang, Hyunggoo; Chae, Hoseok; Hwang, Hee

    2015-01-01

    Objectives To design a cloud computing-based Healthcare Software-as-a-Service (SaaS) Platform (HSP) for delivering healthcare information services with low cost, high clinical value, and high usability. Methods We analyzed the architecture requirements of an HSP, including the interface, business services, cloud SaaS, quality attributes, privacy and security, and multi-lingual capacity. For cloud-based SaaS services, we focused on Clinical Decision Service (CDS) content services, basic functional services, and mobile services. Microsoft's Azure cloud computing for Infrastructure-as-a-Service (IaaS) and Platform-as-a-Service (PaaS) was used. Results The functional and software views of an HSP were designed in a layered architecture. External systems can be interfaced with the HSP using SOAP and REST/JSON. The multi-tenancy model of the HSP was designed as a shared database, with a separate schema for each tenant through a single application, although healthcare data can be physically located on a cloud or in a hospital, depending on regulations. The CDS services were categorized into rule-based services for medications, alert registration services, and knowledge services. Conclusions We expect that cloud-based HSPs will allow small and mid-sized hospitals, in addition to large-sized hospitals, to adopt information infrastructures and health information technology with low system operation and maintenance costs. PMID:25995962

  18. Utilization of Condensed Distillers Solubles as Nutrient Supplement for Production of Nisin and Lactic Acid from Whey

    NASA Astrophysics Data System (ADS)

    Liu, Chuanbin; Hu, Bo; Chen, Shulin; Glass, Richard W.

    The major challenge associated with the rapid growth of the ethanol industry is the usage of the coproducts, i.e., condensed distillers solubles (CDS) and distillers dried grains, which are currently sold as animal feed supplements. As the growth of the livestock industries remains flat, alternative usage of these coproducts is urgently needed. CDS is obtained after the removal of ethanol by distillation from the yeast fermentation of a grain or a grain mixture by condensing the thin stillage fraction to semisolid. In this work, CDS was first characterized and yeast biomass was proven to be the major component of CDS. CDS contained 7.50% crude protein but with only 42% of that protein being water soluble. Then, CDS was applied as a nutrient supplement for simultaneous production of nisin and lactic acid by Lactococcus lactis subsp. lactis (ATCC 11454). Although CDS was able to support bacteria growth and nisin production, a strong inhibition was observed when CDS was overdosed. This may be caused by the existence of the major ethanol fermentation byproducts, especially lactate and acetate, in CDS. In the final step, the CDS based medium composition for nisin and lactic acid production was optimized using response surface methodology.

  19. Computerized clinical documentation system in the pediatric intensive care unit

    PubMed Central

    2001-01-01

    Background To determine whether a computerized clinical documentation system (CDS): 1) decreased time spent charting and increased time spent in patient care; 2) decreased medication errors; 3) improved clinical decision making; 4) improved quality of documentation; and/or 5) improved shift to shift nursing continuity. Methods Before and after implementation of CDS, a time study involving nursing care, medication delivery, and normalization of serum calcium and potassium values was performed. In addition, an evaluation of completeness of documentation and a clinician survey of shift to shift reporting were also completed. This was a modified one group, pretest-posttest design. Results With the CDS there was: improved legibility and completeness of documentation, data with better accessibility and accuracy, no change in time spent in direct patient care or charting by nursing staff. Incidental observations from the study included improved management functions of our nurse manager; improved JCAHO documentation compliance; timely access to clinical data (labs, vitals, etc); a decrease in time and resource use for audits; improved reimbursement because of the ability to reconstruct lost charts; limited human data entry by automatic data logging; eliminated costs of printing forms. CDS cost was reasonable. Conclusions When compared to a paper chart, the CDS provided a more legible, compete, and accessible patient record without affecting time spent in direct patient care. The availability of the CDS improved shift to shift reporting. Other observations showed that the CDS improved management capabilities; helped physicians deliver care; improved reimbursement; limited data entry errors; and reduced costs. PMID:11604105

  20. The Influence of Child-Directed Speech on Word Learning and Comprehension.

    PubMed

    Foursha-Stevenson, Cassandra; Schembri, Taylor; Nicoladis, Elena; Eriksen, Cody

    2017-04-01

    This paper describes an investigation into the function of child-directed speech (CDS) across development. In the first experiment, 10-21-month-olds were presented with familiar words in CDS and trained on novel words in CDS or adult-directed speech (ADS). All children preferred the matching display for familiar words. However, only older toddlers in the CDS condition preferred the matching display for novel words. In Experiment 2, children 3-6 years of age were presented with a sentence comprehension task in CDS or ADS. Older children performed better overall than younger children with 5- and 6-year-olds performing above chance regardless of speech condition, while 3- and 4-year-olds only performed above chance when the sentences were presented in CDS. These findings provide support for the theory that CDS is most effective at the beginning of acquisition for particular constructions (e.g. vocabulary acquisition, syntactic comprehension) rather than at a particular age or for a particular task.

  1. Improving geriatric prescribing in the ED: a qualitative study of facilitators and barriers to clinical decision support tool use.

    PubMed

    Vandenberg, Ann E; Vaughan, Camille P; Stevens, Melissa; Hastings, Susan N; Powers, James; Markland, Alayne; Hwang, Ula; Hung, William; Echt, Katharina V

    2017-02-01

    Clinical decision support (CDS) may improve prescribing for older adults in the Emergency Department (ED) if adopted by providers. Existing prescribing order entry processes were mapped at an initial Veterans Administration Medical Center site, demonstrating cognitive burden, effort and safety concerns. Geriatric order sets incorporating 2012 Beers guidelines and including geriatric prescribing advice and prepopulated order options were developed. Geriatric order sets were implemented at two sites as part of the multicomponent 'Enhancing Quality of Prescribing Practices for Older Veterans Discharged from the Emergency Department' quality improvement initiative. Facilitators and barriers to order sets use at the two sites were evaluated. Phone interviews were conducted with two provider groups (n = 20), those 'EQUiPPED' with the interventions (n = 10, 5 at each site) and Comparison providers who were only exposed to order sets through a clickable option on the ED order menu within the patient's medical record (n = 10, 5 at each site). All providers were asked about order set 'use' and 'usefulness'. Users (n = 11) were asked about 'usability'. Order set adopters described 'usefulness' in terms of 'safety' and 'efficiency', whereas order set consultants and order set non-users described 'usefulness' in terms of 'information' or 'training'. Provider 'autonomy', 'comfort' level with existing tools, and 'learning curve' were stated as barriers to use. Quantifying efficiency advantages and communicating safety benefit over preexisting practices and tools may improve adoption of CDS in ED and in other settings of care. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. Photodegradation of rhodamine B over biomass-derived activated carbon supported CdS nanomaterials under visible irradiation

    NASA Astrophysics Data System (ADS)

    Huang, Hai-Bo; Wang, Yu; Cai, Feng-Ying; Jiao, Wen-Bin; Zhang, Ning; Liu, Cheng; Cao, Hai-Lei; Lü, Jian

    2017-12-01

    A family of new CdS@SAC composite materials was successfully prepared through the deposition of as-synthesized CdS nanomaterials on various lotus-seedpod-derived activated carbon (SAC) materials. The SAC supports derived at different activation temperatures exhibited considerably large surface areas and various microstructures that were responsible for the enhanced photocatalytic performance of CdS@SAC composite materials towards the photodegradation of rhodamine B (RhB) under visible irradiation. The best-performing CdS@SAC-800 showed excellent photocatalytic activity with a rate constant of ca. 2.40×10–2 min–1, which was approximately 13 times higher than that of the CdS precursor. Moreover, the estimated band gap energy of CdS@SAC-800 (1.99 eV) was significantly lower than that of the CdS precursor (2.22 eV), which suggested considerable strength of interface contact between the CdS and carbon support, as well as efficient light harvesting capacity of the composite material. Further photocatalytic study indicated that the SAC supports enhanced synergistically the accessibility of organic substrates, the efficiency of solar energy harvesting, as well as the separation of photogenerated electrons and holes in this system. Improved photocatalytic activity of the composite materials was largely due to the increased generation of active species such as h+, OH•, O2•‑ etc. This work provides a facile and low-cost pathway to fabricate composite photocatalysts for viable degradation of organic pollutants.

  3. Five-Factor Personality Domains, Self-Efficacy, Career-Outcome Expectations, and Career Indecision

    ERIC Educational Resources Information Center

    Feldt, Ronald C.; Woelfel, Cheryl

    2009-01-01

    According to social cognitive career theory, decisions to pursue a career may be influenced by self-efficacy expectations and anticipated career outcomes, thus we examined the incremental validity of these constructs beyond gender and personality. 179 undergraduate college students completed a survey, the Career Decision Scale (CDS), and the NEO…

  4. CdS loaded on coal based activated carbon nanofibers with enhanced photocatalytic property

    NASA Astrophysics Data System (ADS)

    Guo, Jixi; Guo, Mingxi; Jia, Dianzeng; Song, Xianli; Tong, Fenglian

    2016-08-01

    The coal based activated carbon nanofibers (CBACFs) were prepared by electrospinning a mixture of polyacrylonitrile (PAN) and acid treated coal. Cadmium sulfide (CdS) nanoparticles loaded on CBACFs were fabricated by solvothermal method. The obtained samples were characterized by FESEM, TEM, and XRD. The results reveal that the CdS nanoparticles are homogeneously dispersed on the surfaces of CBACFs. The CdS/CBACFs nanocomposites exhibited higher photoactivity for photodegradation of methyl blue (MB) under visible light irradiation than pure CdS nanoparticles. CBACFs can be used as low cost support materials for the preparation of nanocomposites with high photocatalytic activity.

  5. Immobilization of CdS nanoparticles formed in reverse micelles onto aluminosilicate supports and their photocatalytic properties.

    PubMed

    Hirai, Takayuki; Bando, Yoko

    2005-08-15

    CdS nanoparticles, prepared in reverse micellar system, were immobilized onto thiol-modified aluminosilicate particles (ASSH) by a simple operation: addition of ASSH in the micellar solution and mild stirring. The resulting CdS nanoparticles-aluminosilicate composites (ASCdS) were used as photocatalysts for H2 generation from 2-propanol aqueous solution. The chemical properties of the aluminosilicate, such as affinity for water and other reactants, were found to affect the photocatalytic property of the CdS nanoparticles immobilized. Zeolite particles, having affinity for water and 2-propanol, gave a good ASCdS photocatalyst with respect to H2 generation.

  6. Cascade Distillation Subsystem Development: Progress Toward a Distillation Comparison Test

    NASA Technical Reports Server (NTRS)

    Callahan, M. R.; Lubman, A.; Pickering, Karen D.

    2009-01-01

    Recovery of potable water from wastewater is essential for the success of long-duration manned missions to the Moon and Mars. Honeywell International and a team from NASA Johnson Space Center (JSC) are developing a wastewater processing subsystem that is based on centrifugal vacuum distillation. The wastewater processor, referred to as the Cascade Distillation Subsystem (CDS), utilizes an innovative and efficient multistage thermodynamic process to produce purified water. The rotary centrifugal design of the system also provides gas/liquid phase separation and liquid transport under microgravity conditions. A five-stage subsystem unit has been designed, built, delivered and integrated into the NASA JSC Advanced Water Recovery Systems Development Facility for performance testing. A major test objective of the project is to demonstrate the advancement of the CDS technology from the breadboard level to a subsystem level unit. An initial round of CDS performance testing was completed in fiscal year (FY) 2008. Based on FY08 testing, the system is now in development to support an Exploration Life Support (ELS) Project distillation comparison test expected to begin in early 2009. As part of the project objectives planned for FY09, the system will be reconfigured to support the ELS comparison test. The CDS will then be challenged with a series of human-gene-rated waste streams representative of those anticipated for a lunar outpost. This paper provides a description of the CDS technology, a status of the current project activities, and data on the system s performance to date.

  7. Phylogenomic Resolution of the Phylogeny of Laurasiatherian Mammals: Exploring Phylogenetic Signals within Coding and Noncoding Sequences.

    PubMed

    Chen, Meng-Yun; Liang, Dan; Zhang, Peng

    2017-08-01

    The interordinal relationships of Laurasiatherian mammals are currently one of the most controversial questions in mammalian phylogenetics. Previous studies mainly relied on coding sequences (CDS) and seldom used noncoding sequences. Here, by data mining public genome data, we compiled an intron data set of 3,638 genes (all introns from a protein-coding gene are considered as a gene) (19,055,073 bp) and a CDS data set of 10,259 genes (20,994,285 bp), covering all major lineages of Laurasiatheria (except Pholidota). We found that the intron data contained stronger and more congruent phylogenetic signals than the CDS data. In agreement with this observation, concatenation and species-tree analyses of the intron data set yielded well-resolved and identical phylogenies, whereas the CDS data set produced weakly supported and incongruent results. Further analyses showed that the phylogeny inferred from the intron data is highly robust to data subsampling and change in outgroup, but the CDS data produced unstable results under the same conditions. Interestingly, gene tree statistical results showed that the most frequently observed gene tree topologies for the CDS and intron data are identical, suggesting that the major phylogenetic signal within the CDS data is actually congruent with that within the intron data. Our final result of Laurasiatheria phylogeny is (Eulipotyphla,((Chiroptera, Perissodactyla),(Carnivora, Cetartiodactyla))), favoring a close relationship between Chiroptera and Perissodactyla. Our study 1) provides a well-supported phylogenetic framework for Laurasiatheria, representing a step towards ending the long-standing "hard" polytomy and 2) argues that intron within genome data is a promising data resource for resolving rapid radiation events across the tree of life. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  8. Honeywell Cascade Distiller System Performance Testing Interim Results

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  9. Neural mechanisms of dissonance: an fMRI investigation of choice justification.

    PubMed

    Kitayama, Shinobu; Chua, Hannah Faye; Tompson, Steven; Han, Shihui

    2013-04-01

    Cognitive dissonance theory proposes that difficult choice produces negatively arousing cognitive conflict (called dissonance), which motivates the chooser to justify her decision by increasing her preference for the chosen option while decreasing her preference for the rejected option. At present, however, neural mechanisms of dissonance are poorly understood. To address this gap of knowledge, we scanned 24 young Americans as they made 60 choices between pairs of popular music CDs. As predicted, choices between CDs that were close (vs. distant) in attractiveness (referred to as difficult vs. easy choices) resulted in activations of the dorsal anterior cingulate cortex (dACC), a brain region associated with cognitive conflict, and the left anterior insula (left aINS), a region often linked with aversive emotional arousal. Importantly, a separate analysis showed that choice-justifying attitude change was predicted by the in-choice signal intensity of the posterior cingulate cortex (PCC), a region that is linked to self-processing. The three regions identified (dACC, left aINS, and PCC) were correlated, within-subjects, across choices. The results were interpreted to support the hypothesis that cognitive dissonance plays a key role in producing attitudes that justify the choice. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. CDS, UX, and System Redesign - Promising Techniques and Tools to Bridge the Evidence Gap.

    PubMed

    McGinn, Thomas

    2015-01-01

    In this special issue of eGEMs, we explore the struggles related to bringing evidence into day-to-day practice, what I define as the "evidence gap." We are all aware of high quality evidence in the form of guidelines, randomized clinical trials for treatments and diagnostic tests, and clinical prediction rules, which are all readily available online. We also know that electronic health records (EHRs) are now ubiquitous in health care and in most practices across the country. How we marry this high quality evidence and the practice of medicine through effective decision support is a major challenge. All of the articles in this issue explore, in some fashion, CDS systems and how we can best bring providers and their work environment to the evidence. We are at the very early stages of the science of usability. Much more research and funding is needed in this area if we hope to improve the dissemination and implementation of evidence in practice. While the featured examples, techniques, and tools in the special issue are a promising start to improving usability and CDS, many of the papers highlight current gaps in knowledge and a great need for generalizable approaches. The great promise is for "learning" approaches to generate new evidence and to integrate this evidence in reliable, patient-centered ways at scale using new technology. Closing the evidence gap is a real possibility, but only if the community works together to innovate and invest in research on the best ways to disseminate, communicate, and implement evidence in practice.

  11. High-end clinical domain information systems for effective healthcare delivery.

    PubMed

    Mangalampalli, Ashish; Rama, Chakravarthy; Muthiyalian, Raja; Jain, Ajeet K

    2007-01-01

    The Electronic Health Record (EHR) provides doctors with a quick, reliable, secure, real-time and user-friendly source of all relevant patient data. The latest information system technologies, such as Clinical Data Warehouses (CDW), Clinical Decision-Support (CDS) systems and data-mining techniques (Online Analytical Processing (OLAP) and Online Transactional Processing (OLTP)), are used to maintain and utilise patient data intelligently, based on the users' requirements. Moreover, clinical trial reports for new drug approvals are now being submitted electronically for faster and easier processing. Also, information systems are used in educating patients about the latest developments in medical science through the internet and specially configured kiosks in hospitals and clinics.

  12. In Situ Localized Surface Plasmon Resonance (LSPR) Spectroscopy to Investigate Kinetics of Chemical Bath Deposition of CdS Thin Films

    DOE PAGES

    Kalyanaraman, Ramki; Taz, Humaira; Ruther, Rose E.; ...

    2015-02-11

    Techniques that can characterize the early stages of thin film deposition from liquid phase processes can aid greatly in our understanding of mechanistic aspects of chemical bath deposition (CBD). Here we have used localized surface plasmon resonance (LSPR) spectroscopy to monitor in-situ the kinetics of early-stage growth of cadmium sulfide (CdS) thin films on Ag nanoparticle on quartz substrates. Real-time shift during CdS deposition showed that the LSPR wavelength red shifted rapidly due to random deposition of CdS on the substrate, but saturated at longer times. LSPR modeling showed that these features could be interpreted as an initial deposition ofmore » CdS islands followed by preferential deposition onto itself. The CdS also showed significantly enhanced Raman signals up to 170 times due to surface enhanced raman scattering (SERS) from the CdS/Ag NP regions. The ex-situ SERS effect supported the LSPR shift suggesting that these techniques could be used to understand nucleation and growth phenomena from the liquid phase.« less

  13. Negative surface streamers propagating on TiO2 and γ-Al2O3-supported Ag catalysts: ICCD imaging and modeling study

    NASA Astrophysics Data System (ADS)

    Kim, Hyun-Ha; Teramoto, Yoshiyuki; Ogata, Atsushi; Kang, Woo Seok; Hur, Min; Song, Young-Hoon

    2018-06-01

    Surface streamers propagating on the surface of titanium dioxide (TiO2) and alumina (γ-Al2O3) were studied in negative polarity using intensified charge coupled device (ICCD) imaging and numerical simulation. Detailed time-resolved ICCD images of cathode-directed streamers (CDSs) emanating from a ground electrode are first presented in this report. Instead of primary streamers in positive polarity, only a glow-like discharge appeared in the early stage at the cathode under negative polarity. After this discharge disappeared, a counter-propagating CDS initiated from the ground electrode (anode). Numerical simulation indicated that strong electric fields at the pellet-anode and the formation of positive ion rich local spots were the main reason for the CDS formation near the ground electrode. The maximum velocity was 750 km s‑1 for Ag-supported γ-Al2O3 and 550 km s‑1 for Ag-supported TiO2, respectively. In contrast to the CDS in the gas-phase with a positive polarity, the CDS in a catalyst packed-bed under negative polarity showed more branching and a larger number of streamers in the presence of oxygen than in pure N2.

  14. Cascade Distillation Subsystem Development: Early Results From the Exploration Life Support Distillation Technology Comparison Test

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Patel, Vipul; Pickering, Karen D.

    2009-01-01

    In 2009, the Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, CA) was assessed in the National Aeronautics and Space Administration (NASA) Exploration Life Support (ELS) distillation comparison test. The purpose of the test was to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. The CDS portion of the comparison test was conducted between May 6 and August 19, 2009. The system was challenged with two pretreated test solutions, each intended to represent a feasible wastewater generated in a surface habitat. The 30-day equivalent wastewater loading volume for a crew of four was processed for each wastewater solution. Test Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. Test Solution 2 contained the addition of human-generated hygiene wastewater to the solution 1 waste stream components. Approximately 1500 kg of total wastewater was processed through the CDS during testing. Respective recoveries per solution were 93.4 +/- 0.7 and 90.3 +/- 0.5%. The average specific energy of the system was calculated to be less than 130 W-hr/kg. The following paper provides detailed information and data on the performance of the CDS as challenged per the ELS distillation comparison test.

  15. An Electronic Clinical Decision Support Tool to Assist Primary Care Providers in Cardiovascular Disease Risk Management: Development and Mixed Methods Evaluation

    PubMed Central

    Joshi, Rohina; Webster, Ruth J; Groenestein, Patrick; Usherwood, Tim P; Heeley, Emma; Turnbull, Fiona M; Lipman, Alexandra; Patel, Anushka A

    2009-01-01

    Background Challenges remain in translating the well-established evidence for management of cardiovascular disease (CVD) risk into clinical practice. Although electronic clinical decision support (CDS) systems are known to improve practitioner performance, their development in Australian primary health care settings is limited. Objectives Study aims were to (1) develop a valid CDS tool that assists Australian general practitioners (GPs) in global CVD risk management, and (2) preliminarily evaluate its acceptability to GPs as a point-of-care resource for both general and underserved populations. Methods CVD risk estimation (based on Framingham algorithms) and risk-based management advice (using recommendations from six Australian guidelines) were programmed into a software package. Tool validation: Data from 137 patients attending a physician’s clinic were analyzed to compare the tool’s risk scores with those obtained from an independently programmed algorithm in a separate statistics package. The tool’s management advice was compared with a physician’s recommendations based on a manual review of the guidelines. Field test: The tool was then tested with 21 GPs from eight general practices and three Aboriginal Medical Services. Customized CDS-based recommendations were generated for 200 routinely attending patients (33% Aboriginal) using information extracted from the health record by a research assistant. GPs reviewed these recommendations during each consultation. Changes in CVD risk factor measurement and management were recorded. In-depth interviews with GPs were conducted. Results Validation testing: The tool’s risk assessment algorithm correlated very highly with the independently programmed version in the separate statistics package (intraclass correlation coefficient 0.999). For management advice, there were only two cases of disagreement between the tool and the physician. Field test: GPs found 77% (153/200) of patient outputs easy to understand and agreed with screening and prescribing recommendations in 72% and 64% of outputs, respectively; 26% of patients had their CVD risk factor history updated; 73% had at least one CVD risk factor measured or tests ordered. For people assessed at high CVD risk (n = 82), 10% and 9%, respectively, had lipid-lowering and BP-lowering medications commenced or dose adjustments made, while 7% newly commenced anti-platelet medications. Three key qualitative findings emerged: (1) GPs found the tool enabled a systematic approach to care; (2) the tool greatly influenced CVD risk communication; (3) successful implementation into routine care would require integration with practice software, minimal data entry, regular revision with updated guidelines, and a self-auditing feature. There were no substantive differences in study findings for Aboriginal Medical Services GPs, and the tool was generally considered appropriate for use with Aboriginal patients. Conclusion A fully-integrated, self-populating, and potentially Internet-based CDS tool could contribute to improved global CVD risk management in Australian primary health care. The findings from this study will inform a large-scale trial intervention. PMID:20018588

  16. An electronic clinical decision support tool to assist primary care providers in cardiovascular disease risk management: development and mixed methods evaluation.

    PubMed

    Peiris, David P; Joshi, Rohina; Webster, Ruth J; Groenestein, Patrick; Usherwood, Tim P; Heeley, Emma; Turnbull, Fiona M; Lipman, Alexandra; Patel, Anushka A

    2009-12-17

    Challenges remain in translating the well-established evidence for management of cardiovascular disease (CVD) risk into clinical practice. Although electronic clinical decision support (CDS) systems are known to improve practitioner performance, their development in Australian primary health care settings is limited. Study aims were to (1) develop a valid CDS tool that assists Australian general practitioners (GPs) in global CVD risk management, and (2) preliminarily evaluate its acceptability to GPs as a point-of-care resource for both general and underserved populations. CVD risk estimation (based on Framingham algorithms) and risk-based management advice (using recommendations from six Australian guidelines) were programmed into a software package. Tool validation: Data from 137 patients attending a physician's clinic were analyzed to compare the tool's risk scores with those obtained from an independently programmed algorithm in a separate statistics package. The tool's management advice was compared with a physician's recommendations based on a manual review of the guidelines. Field test: The tool was then tested with 21 GPs from eight general practices and three Aboriginal Medical Services. Customized CDS-based recommendations were generated for 200 routinely attending patients (33% Aboriginal) using information extracted from the health record by a research assistant. GPs reviewed these recommendations during each consultation. Changes in CVD risk factor measurement and management were recorded. In-depth interviews with GPs were conducted. Validation testing: the tool's risk assessment algorithm correlated very highly with the independently programmed version in the separate statistics package (intraclass correlation coefficient 0.999). For management advice, there were only two cases of disagreement between the tool and the physician. Field test: GPs found 77% (153/200) of patient outputs easy to understand and agreed with screening and prescribing recommendations in 72% and 64% of outputs, respectively; 26% of patients had their CVD risk factor history updated; 73% had at least one CVD risk factor measured or tests ordered. For people assessed at high CVD risk (n = 82), 10% and 9%, respectively, had lipid-lowering and BP-lowering medications commenced or dose adjustments made, while 7% newly commenced anti-platelet medications. Three key qualitative findings emerged: (1) GPs found the tool enabled a systematic approach to care; (2) the tool greatly influenced CVD risk communication; (3) successful implementation into routine care would require integration with practice software, minimal data entry, regular revision with updated guidelines, and a self-auditing feature. There were no substantive differences in study findings for Aboriginal Medical Services GPs, and the tool was generally considered appropriate for use with Aboriginal patients. A fully-integrated, self-populating, and potentially Internet-based CDS tool could contribute to improved global CVD risk management in Australian primary health care. The findings from this study will inform a large-scale trial intervention.

  17. Unravelling referral paths relating to the dental care of children: a study in Liverpool.

    PubMed

    Harris, Rebecca V; Pender, Susan M; Merry, Alison; Leo, Anthony

    2008-04-01

    To describe primary care referral networks relating to children's dental care and the main influences on referral decisions taken by dentists working in a primary care setting. A postal questionnaire to all 130 general dental practitioners (GDPs) in contract with Primary Care Trusts (PCTs), and 24 Community Dental Service (CDS) dentists in Liverpool. Characteristics of patient groups and factors influencing the choice of referral pathway of children referred from primary dental care. There were good responses rates (110 [85%] GDPs and 22 [92%] CDS dentists). The two main reasons why GDPs referred children to hospitals were (a) for treatment under general anaesthetic (GA) or relative analgesia (RA) and (b) for restorative care of dentally anxious children. GDPs also referred anxious children requiring simple restorative care and/or RA to the CDS. Only eight GDPs (7%) cited a lack of experience as a reason for referral of dentally anxious children for simple restorative care, compared to 53 (48%) who cited a lack of RA facilities, and 25 (23%) who cited financial considerations. GDPs refer children to both hospital services and the CDS, and identify a lack of RA facilities and economic pressures as key reasons for referral.

  18. Easy Preparation and Photoelectrochemical Properties of CdS Nanoparticle/Graphene Nanosheet Nanocomposites Using Supercritical Carbon Dioxide.

    PubMed

    Yan, Shancheng; Xu, Xin; Jiang, Chao; Pan, Lijia; Shi, Yi; Hu, Dong; Cao, Zhenglin

    2016-03-01

    Graphene nanosheets (GNSs) were modified with CdS nanoparticles (NPs) using supercritical CO2 (SC CO2), which has gas-like diffusivity, low viscosity, and near-zero surface tension. The resulting CdS NP/GNS nanocomposites were characterized by field-emission scanning electron microscopy, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, Raman spectroscopy, and photoluminescence spectroscopy. Distinct morphologies of CdS NP/GNS nanocomposites decorated on the GNS surface were obtained at different SC CO2 pressures, temperatures, and durations and in different sources. Results showed that the sources and SC CO2 significantly influenced the aggregation or assembly behavior of the CdS NP/GNS nanocomposites on the GNSs. The formation mechanism of the distinct nanohybrid structures was studied by Raman mapping. A difference was noted between the Raman spectra of pristine graphene nanosheets and CdS NP/GNS nanocomposites. This result can be ascribed to the CdS NPs anchored onto the GNS defects and to the improved quality of the GNSs under SC CO2. The photo-current densities of CdS NP/GNS nanocomposites were at least three times higher than that of the pristine CdS NPs at the same applied voltage for photoelectrochemical water splitting. The findings suggested that highly efficient graphene-supported NP photoelectrocatalysts can be fabricated by the supercritical fluid method and that graphene can serve as a favorable photoelectrocatalytic carrier, with promising potential applications in environmental and energy fields. Keywords: Graphene Nanosheets, Cadmium Sulfide, Raman Spectroscopy, Photoelectrochemical.

  19. Optical characterization of CdS nanoparticles embedded into the comb-type amphiphilic graft copolymer

    NASA Astrophysics Data System (ADS)

    Kalaycı, Özlem A.; Duygulu, Özgür; Hazer, Baki

    2013-01-01

    This study refers to the synthesis and characterization of a novel organic/inorganic hybrid nanocomposite material containing cadmium sulfide (CdS) nanoparticles. For this purpose, a series of polypropylene (PP)-g-polyethylene glycol (PEG), PP-g-PEG comb-type amphiphilic graft copolymers were synthesized. PEGs with Mn = 400, 2000, 3350, and 8000 Da were used and the graft copolymers obtained were coded as PPEG400, PPEG2000, PPEG3350, and PPEG8000. CdS nanoparticles were formed in tetrahydrofuran solution of PP-g-PEG amphiphilic comb-type copolymer by the reaction between aqueous solutions of Na2S and Cd(CH3COO)2 simultaneously. Micelle formation of PPEG2000 comb-type amphiphilic graft copolymer in both solvent/non-solvent (petroleum ether-THF) by transmission electron microscopy (TEM). The optical characteristics, size morphology, phase analysis, and dispersion of CdS nanoparticles embedded in PPEG400, PPEG2000, PPEG3350, and PPEG8000 comb-type amphiphilic graft copolymer micelles were determined by high resolution TEM (HRTEM), energy dispersive spectroscopy, UV-vis spectroscopy, and fluorescence emission spectroscopy techniques. The aggregate size of PPEG2000-CdS is between 10 and 50 nm; however, in the case of PPEG400-CdS, PPEG3350-CdS, and PPEG8000-CdS samples, it is up to approximately 100 nm. The size of CdS quantum dots in the aggregates for PPEG2000 and PPEG8000 samples was observed as 5 nm by HRTEM analysis, and this result was also supported by UV-vis absorbance spectra and fluorescence emission spectra.

  20. Usability Evaluation of a Clinical Decision Support System for Geriatric ED Pain Treatment.

    PubMed

    Genes, Nicholas; Kim, Min Soon; Thum, Frederick L; Rivera, Laura; Beato, Rosemary; Song, Carolyn; Soriano, Jared; Kannry, Joseph; Baumlin, Kevin; Hwang, Ula

    2016-01-01

    Older adults are at risk for inadequate emergency department (ED) pain care. Unrelieved acute pain is associated with poor outcomes. Clinical decision support systems (CDSS) hold promise to improve patient care, but CDSS quality varies widely, particularly when usability evaluation is not employed. To conduct an iterative usability and redesign process of a novel geriatric abdominal pain care CDSS. We hypothesized this process would result in the creation of more usable and favorable pain care interventions. Thirteen emergency physicians familiar with the Electronic Health Record (EHR) in use at the study site were recruited. Over a 10-week period, 17 1-hour usability test sessions were conducted across 3 rounds of testing. Participants were given 3 patient scenarios and provided simulated clinical care using the EHR, while interacting with the CDSS interventions. Quantitative System Usability Scores (SUS), favorability scores and qualitative narrative feedback were collected for each session. Using a multi-step review process by an interdisciplinary team, positive and negative usability issues in effectiveness, efficiency, and satisfaction were considered, prioritized and incorporated in the iterative redesign process of the CDSS. Video analysis was used to determine the appropriateness of the CDS appearances during simulated clinical care. Over the 3 rounds of usability evaluations and subsequent redesign processes, mean SUS progressively improved from 74.8 to 81.2 to 88.9; mean favorability scores improved from 3.23 to 4.29 (1 worst, 5 best). Video analysis revealed that, in the course of the iterative redesign processes, rates of physicians' acknowledgment of CDS interventions increased, however most rates of desired actions by physicians (such as more frequent pain score updates) decreased. The iterative usability redesign process was instrumental in improving the usability of the CDSS; if implemented in practice, it could improve geriatric pain care. The usability evaluation process led to improved acknowledgement and favorability. Incorporating usability testing when designing CDSS interventions for studies may be effective to enhance clinician use.

  1. Development, Evaluation and Implementation of Chief Complaint Groupings to Activate Data Collection: A Multi-Center Study of Clinical Decision Support for Children with Head Trauma.

    PubMed

    Deakyne, S J; Bajaj, L; Hoffman, J; Alessandrini, E; Ballard, D W; Norris, R; Tzimenatos, L; Swietlik, M; Tham, E; Grundmeier, R W; Kuppermann, N; Dayan, P S

    2015-01-01

    Overuse of cranial computed tomography scans in children with blunt head trauma unnecessarily exposes them to radiation. The Pediatric Emergency Care Applied Research Network (PECARN) blunt head trauma prediction rules identify children who do not require a computed tomography scan. Electronic health record (EHR) based clinical decision support (CDS) may effectively implement these rules but must only be provided for appropriate patients in order to minimize excessive alerts. To develop, implement and evaluate site-specific groupings of chief complaints (CC) that accurately identify children with head trauma, in order to activate data collection in an EHR. As part of a 13 site clinical trial comparing cranial computed tomography use before and after implementation of CDS, four PECARN sites centrally developed and locally implemented CC groupings to trigger a clinical trial alert (CTA) to facilitate the completion of an emergency department head trauma data collection template. We tested and chose CC groupings to attain high sensitivity while maintaining at least moderate specificity. Due to variability in CCs available, identical groupings across sites were not possible. We noted substantial variability in the sensitivity and specificity of seemingly similar CC groupings between sites. The implemented CC groupings had sensitivities greater than 90% with specificities between 75-89%. During the trial, formal testing and provider feedback led to tailoring of the CC groupings at some sites. CC groupings can be successfully developed and implemented across multiple sites to accurately identify patients who should have a CTA triggered to facilitate EHR data collection. However, CC groupings will necessarily vary in order to attain high sensitivity and moderate-to-high specificity. In future trials, the balance between sensitivity and specificity should be considered based on the nature of the clinical condition, including prevalence and morbidity, in addition to the goals of the intervention being considered.

  2. Cascade Distiller System Performance Testing Interim Results

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  3. Expressing clinical data sets with openEHR archetypes: a solid basis for ubiquitous computing.

    PubMed

    Garde, Sebastian; Hovenga, Evelyn; Buck, Jasmin; Knaup, Petra

    2007-12-01

    The purpose of this paper is to analyse the feasibility and usefulness of expressing clinical data sets (CDSs) as openEHR archetypes. For this, we present an approach to transform CDS into archetypes, and outline typical problems with CDS and analyse whether some of these problems can be overcome by the use of archetypes. Literature review and analysis of a selection of existing Australian, German, other European and international CDSs; transfer of a CDS for Paediatric Oncology into openEHR archetypes; implementation of CDSs in application systems. To explore the feasibility of expressing CDS as archetypes an approach to transform existing CDSs into archetypes is presented in this paper. In case of the Paediatric Oncology CDS (which consists of 260 data items) this lead to the definition of 48 openEHR archetypes. To analyse the usefulness of expressing CDS as archetypes, we identified nine problems with CDS that currently remain unsolved without a common model underpinning the CDS. Typical problems include incompatible basic data types and overlapping and incompatible definitions of clinical content. A solution to most of these problems based on openEHR archetypes is motivated. With regard to integrity constraints, further research is required. While openEHR cannot overcome all barriers to Ubiquitous Computing, it can provide the common basis for ubiquitous presence of meaningful and computer-processable knowledge and information, which we believe is a basic requirement for Ubiquitous Computing. Expressing CDSs as openEHR archetypes is feasible and advantageous as it fosters semantic interoperability, supports ubiquitous computing, and helps to develop archetypes that are arguably of better quality than the original CDS.

  4. Cascade Distillation Subsystem Development: Early Results from the Exploration Life Support Distillation Technology Comparison Test

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Patel, Vipul; Pickering, Karen D.

    2010-01-01

    In 2009, the Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, California) was assessed in the National Aeronautics and Space Administration (NASA) Exploration Life Support (ELS) distillation comparison test. The purpose of the test was to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. The CDS portion of the comparison test was conducted between May 6 and August 19, 2009. The system was challenged with two pretreated test solutions, each intended to represent a feasible wastewater generated in a surface habitat. The 30-day equivalent wastewater loading volume for a crew of four was intended to be processed for each wastewater solution. Test Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. Test Solution 2 contained the addition of human-generated hygiene wastewater to the solution 1 waste stream components. Approximately 1500 kg of total wastewater was processed through the CDS during testing. Respective recoveries per solution were 93.4 +/- 0.7 and 90.3 +/- 0.5 percent. The average specific energy of the system during testing was calculated to be less than 120 W-hr/kg. The following paper provides detailed information and data on the performance of the CDS as challenged per the ELS distillation comparison test.

  5. Preemptive Genotyping for Personalized Medicine: Design of the Right Drug, Right Dose, Right Time – Using Genomic Data to Individualize Treatment Protocol

    PubMed Central

    Bielinski, Suzette J.; Olson, Janet E.; Pathak, Jyotishman; Weinshilboum, Richard M.; Wang, Liewei; Lyke, Kelly J.; Ryu, Euijung; Targonski, Paul V.; Van Norstrand, Michael D.; Hathcock, Matthew A.; Takahashi, Paul Y.; McCormick, Jennifer B.; Johnson, Kiley J.; Maschke, Karen J.; Rohrer Vitek, Carolyn R.; Ellingson, Marissa S.; Wieben, Eric D.; Farrugia, Gianrico; Morrisette, Jody A.; Kruckeberg, Keri J.; Bruflat, Jamie K.; Peterson, Lisa M.; Blommel, Joseph H.; Skierka, Jennifer M.; Ferber, Matthew J.; Black, John L.; Baudhuin, Linnea M.; Klee, Eric W.; Ross, Jason L.; Veldhuizen, Tamra L.; Schultz, Cloann G.; Caraballo, Pedro J.; Freimuth, Robert R.; Chute, Christopher G.; Kullo, Iftikhar J.

    2014-01-01

    Objective To report the design and implementation of the Right Drug, Right Dose, Right Time: Using Genomic Data to Individualize Treatment Protocol that was developed to test the concept that prescribers can deliver genome guided therapy at the point-of-care by using preemptive pharmacogenomics (PGx) data and clinical decision support (CDS) integrated in the electronic medical record (EMR). Patients and Methods We used a multivariable prediction model to identify patients with a high risk of initiating statin therapy within 3 years. The model was used to target a study cohort most likely to benefit from preemptive PGx testing among Mayo Clinic Biobank participants with a recruitment goal of 1000 patients. Cox proportional hazards model was utilized using the variables selected through the Lasso shrinkage method. An operational CDS model was adapted to implement PGx rules within the EMR. Results The prediction model included age, sex, race, and 6 chronic diseases categorized by the Clinical Classifications Software for ICD-9 codes (dyslipidemia, diabetes, peripheral atherosclerosis, disease of the blood-forming organs, coronary atherosclerosis and other heart diseases, and hypertension). Of the 2000 Biobank participants invited, 50% provided blood samples, 13% refused, 28% did not respond, and 9% consented but did not provide a blood sample within the recruitment window (October 4, 2012 – March 20, 2013). Preemptive PGx testing included CYP2D6 genotyping and targeted sequencing of 84 PGx genes. Synchronous real-time CDS is integrated in the EMR and flags potential patient-specific drug-gene interactions and provides therapeutic guidance. Conclusion These interventions will improve understanding and implementation of genomic data in clinical practice. PMID:24388019

  6. The ImmProve Project: Leveraging electronic health record data to promote immunization delivery

    PubMed Central

    Bundy, David G.; Persing, Nichole M.; Solomon, Barry S.; King, Tracy M.; Murakami, Peter; Thompson, Richard E.; Engineer, Lilly D.; Lehmann, Christoph U.; Miller, Marlene R.

    2013-01-01

    Objective Though an essential pediatric preventive service, immunizations are challenging to deliver reliably. Our objective was to measure the impact on pediatric immunization rates of providing clinicians with electronic health record-derived immunization prompting. Methods Operating in a large, urban, hospital-based pediatric primary care clinic, we evaluated 2 interventions to improve immunization delivery to children ages 2, 6, and 13 years: point-of-care, patient-specific electronic clinical decision support (CDS) when children overdue for immunizations presented for care and provider-specific bulletins listing children overdue for immunizations. Results Overall, the proportion of children up-to-date for a composite of recommended immunizations at ages 2, 6, and 13 years was not different in the intervention (CDS active) and historical control (CDS not active) periods; historical immunization rates were high. The proportion of children receiving 2 doses of hepatitis A immunization prior to their second birthday was significantly improved during the intervention period. Human papilloma virus (HPV) immunization delivery was low during both control and intervention periods and was unchanged for 13-year-olds. For 14-year-olds, however, 4 of the 5 highest quarterly rates of complete HPV immunization occurred in the final year of the intervention. Provider-specific bulletins listing children overdue for immunizations increased the likelihood of identified children receiving catch-up hepatitis A immunizations (hazard ratio: 1.32 [95% confidence interval (CI): 1.12–1.56]); results for HPV and the composite of recommended immunizations were of a similar magnitude but not statistically significant. Conclusions In our patient population, with high baseline uptake of recommended immunizations, electronic health record-derived immunization prompting had a limited effect on immunization delivery. Benefit was more clearly demonstrated for newer immunizations with lower baseline uptake. PMID:23726754

  7. Improving immunization delivery using an electronic health record: the ImmProve project.

    PubMed

    Bundy, David G; Persing, Nichole M; Solomon, Barry S; King, Tracy M; Murakami, Peter N; Thompson, Richard E; Engineer, Lilly D; Lehmann, Christoph U; Miller, Marlene R

    2013-01-01

    Though an essential pediatric preventive service, immunizations are challenging to deliver reliably. Our objective was to measure the impact on pediatric immunization rates of providing clinicians with electronic health record-derived immunization prompting. Operating in a large, urban, hospital-based pediatric primary care clinic, we evaluated 2 interventions to improve immunization delivery to children ages 2, 6, and 13 years: point-of-care, patient-specific electronic clinical decision support (CDS) when children overdue for immunizations presented for care, and provider-specific bulletins listing children overdue for immunizations. Overall, the proportion of children up to date for a composite of recommended immunizations at ages 2, 6, and 13 years was not different in the intervention (CDS active) and historical control (CDS not active) periods; historical immunization rates were high. The proportion of children receiving 2 doses of hepatitis A immunization before their second birthday was significantly improved during the intervention period. Human papillomavirus (HPV) immunization delivery was low during both control and intervention periods and was unchanged for 13-year-olds. For 14-year-olds, however, 4 of the 5 highest quarterly rates of complete HPV immunization occurred in the final year of the intervention. Provider-specific bulletins listing children overdue for immunizations increased the likelihood of identified children receiving catch-up hepatitis A immunizations (hazard ratio 1.32; 95% confidence interval 1.12-1.56); results for HPV and the composite of recommended immunizations were of a similar magnitude but not statistically significant. In our patient population, with high baseline uptake of recommended immunizations, electronic health record-derived immunization prompting had a limited effect on immunization delivery. Benefit was more clearly demonstrated for newer immunizations with lower baseline uptake. Copyright © 2013 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  8. Thermodynamic Analyses of the LCLS-II Cryogenic Distribution System

    DOE PAGES

    Dalesandro, Andrew; Kaluzny, Joshua; Klebaner, Arkadiy

    2016-12-29

    The Linac Coherent Light Source (LCLS) at Stanford Linear Accelerator Center (SLAC) is in the process of being upgraded to a superconducting radio frequency (SRF) accelerator and renamed LCLS-II. This upgrade requires thirty-five 1.3 GHz SRF cryomodules (CM) and two 3.9 GHz CM. A cryogenic distribution system (CDS) is in development by Fermi National Accelerator Laboratory to interconnect the CM Linac with the cryogenic plant (CP). The CDS design utilizes cryogenic helium to support the CM operations with a high temperature thermal shield around 55 K, a low temperature thermal intercepts around 5 K, and a SRF cavity liquid heliummore » supply and sub-atmospheric vapor return both around 2 K. Additionally the design must accommodate a Linac consisting of two parallel cryogenic strings, supported by two independent CP utilizing CDS components such as distribution boxes, transfer lines, feed caps and endcaps. In this paper, we describe the overall layout of the cryogenic distribution system and the major thermodynamic factors which influence the CDS design including heat loads, pressure drops, temperature profiles, and pressure relieving requirements. In addition the paper describes how the models are created to perform the analyses.« less

  9. Use of real-time tools to support field operations of NSF's Lower Atmosphere Observing Facilities

    NASA Astrophysics Data System (ADS)

    Daniels, M.; Stossmeister, G.; Johnson, E.; Martin, C.; Webster, C.; Dixon, M.; Maclean, G.

    2012-12-01

    NCAR's Earth Observing Laboratory (EOL) operates Lower Atmosphere Observing Facilities (LAOF) for the scientific community, under sponsorship of the National Science Foundation. In order to obtain the highest quality dataset during field campaigns, real-time decision-making critically depends on the availability of timely data and reliable communications between field operations staff and instrument operators. EOL incorporates the latest technologies to monitor the health of instrumentation, facilitate remote operations of instrumentation and keep project participants abreast of changing conditions in the field. As the availability of bandwidth on mobile communication networks and the capabilities of their associated devices (smart phone, tablets, etc.) improved, so has the ability of researchers to respond to rapidly changing conditions and coordinate ever more detailed measurements from multiple remote fixed, portable and airborne platforms. This presentation will describe several new tools that EOL is making available to project investigators and how these tools are being used in a mobile computing environment to support enhanced data collection during field campaigns. LAOF platforms such as radars, aircraft, sondes, balloons and surface stations all rely on displays of real-time data for their operations. Data from sondes are ingested into the Global Telecommunications System (GTS) for assimilation into regional forecasting models that help guide project operations. Since many of EOL's projects occur around the globe and at the same time instrument complexity has increased, automated monitoring of instrumentation platforms and systems has become essential. Tools are being developed to allow remote instrument control of our suite of observing systems where feasible. The Computing, Data and Software (CDS) Facility of EOL develops and supports a Field Catalog used in field campaigns for nearly two decades. Today, the Field Catalog serves as a hub for the collection and browsing of field research products, related operational and forecast imagery, project documentation as well as tools for real-time decision-making, communication, mission planning and post analysis. Incorporation of new capabilities into the Field Catalog to support the mobile computing environment and devices has led to the development of new tools which will be described. EOL/CDS has also developed a customized Internet Relay Chat (IRC) chat system to enable communication between all project participants distributed across various land-based, shipboard and airborne remote sites. The CDS chat system has incorporated aspects of fault tolerance in order to handle intermittent communications links. NOAA and NASA have used this chat system for their field missions as well. These new tools were recently deployed in support of the Deep Convective Clouds and Chemistry (DC3) field campaign that took place May - June 2012 in the Central United States. This presentation will show examples of these real-time tools from recent projects. We will also describe some of the challenges, problems and surprises, as well as improvements that have been made to the tools. The capabilities of this system continue to advance, taking advantage of new technology and guided by our experience and feedback from users participating in field campaigns.

  10. PG4KDS: A Model for the Clinical Implementation of Pre-emptive Pharmacogenetics

    PubMed Central

    Hoffman, James M.; Haidar, Cyrine E.; Wilkinson, Mark R.; Crews, Kristine R.; Baker, Donald K.; Kornegay, Nancy M.; Yang, Wenjian; Pui, Ching-Hon; Reiss, Ulrike M.; Gaur, Aditya H.; Howard, Scott C.; Evans, William E.; Broeckel, Ulrich; Relling, Mary V.

    2014-01-01

    Pharmacogenetics is frequently cited as an area for initial focus of the clinical implementation of genomics. Through the PG4KDS protocol, St. Jude Children’s Research Hospital pre-emptively genotypes patients for 230 genes using the Affymetrix Drug Metabolizing Enzymes and Transporters (DMET) Plus array supplemented with a CYP2D6 copy number assay. The PG4KDS protocol provides a rational, stepwise process for implementing gene/drug pairs, organizing data, and obtaining consent from patients and families. Through August 2013, 1559 patients have been enrolled, and 4 gene tests have been released into the electronic health record (EHR) for clinical implementation: TPMT, CYP2D6, SLCO1B1, and CYP2C19. These genes are coupled to 12 high-risk drugs. Of the 1016 patients with genotype test results available, 78% of them had at least one high-risk (i.e., actionable) genotype result placed in their EHR. Each diplotype result released to the EHR is coupled with an interpretive consult that is created in a concise, standardized format. To support-gene based prescribing at the point of care, 55 interruptive clinical decision support (CDS) alerts were developed. Patients are informed of their genotyping result and its relevance to their medication use through a letter. Key elements necessary for our successful implementation have included strong institutional support, a knowledgeable clinical laboratory, a process to manage any incidental findings, a strategy to educate clinicians and patients, a process to return results, and extensive use of informatics, especially CDS. Our approach to pre-emptive clinical pharmacogenetics has proven feasible, clinically useful, and scalable. PMID:24619595

  11. PG4KDS: a model for the clinical implementation of pre-emptive pharmacogenetics.

    PubMed

    Hoffman, James M; Haidar, Cyrine E; Wilkinson, Mark R; Crews, Kristine R; Baker, Donald K; Kornegay, Nancy M; Yang, Wenjian; Pui, Ching-Hon; Reiss, Ulrike M; Gaur, Aditya H; Howard, Scott C; Evans, William E; Broeckel, Ulrich; Relling, Mary V

    2014-03-01

    Pharmacogenetics is frequently cited as an area for initial focus of the clinical implementation of genomics. Through the PG4KDS protocol, St. Jude Children's Research Hospital pre-emptively genotypes patients for 230 genes using the Affymetrix Drug Metabolizing Enzymes and Transporters (DMET) Plus array supplemented with a CYP2D6 copy number assay. The PG4KDS protocol provides a rational, stepwise process for implementing gene/drug pairs, organizing data, and obtaining consent from patients and families. Through August 2013, 1,559 patients have been enrolled, and four gene tests have been released into the electronic health record (EHR) for clinical implementation: TPMT, CYP2D6, SLCO1B1, and CYP2C19. These genes are coupled to 12 high-risk drugs. Of the 1,016 patients with genotype test results available, 78% of them had at least one high-risk (i.e., actionable) genotype result placed in their EHR. Each diplotype result released to the EHR is coupled with an interpretive consult that is created in a concise, standardized format. To support-gene based prescribing at the point of care, 55 interruptive clinical decision support (CDS) alerts were developed. Patients are informed of their genotyping result and its relevance to their medication use through a letter. Key elements necessary for our successful implementation have included strong institutional support, a knowledgeable clinical laboratory, a process to manage any incidental findings, a strategy to educate clinicians and patients, a process to return results, and extensive use of informatics, especially CDS. Our approach to pre-emptive clinical pharmacogenetics has proven feasible, clinically useful, and scalable. © 2014 Wiley Periodicals, Inc.

  12. A prognostic model based on readily available clinical data enriched a pre-emptive pharmacogenetic testing program.

    PubMed

    Schildcrout, Jonathan S; Shi, Yaping; Danciu, Ioana; Bowton, Erica; Field, Julie R; Pulley, Jill M; Basford, Melissa A; Gregg, William; Cowan, James D; Harrell, Frank E; Roden, Dan M; Peterson, Josh F; Denny, Joshua C

    2016-04-01

    We describe the development, implementation, and evaluation of a model to pre-emptively select patients for genotyping based on medication exposure risk. Using deidentified electronic health records, we derived a prognostic model for the prescription of statins, warfarin, or clopidogrel. The model was implemented into a clinical decision support (CDS) tool to recommend pre-emptive genotyping for patients exceeding a prescription risk threshold. We evaluated the rule on an independent validation cohort and on an implementation cohort, representing the population in which the CDS tool was deployed. The model exhibited moderate discrimination with area under the receiver operator characteristic curves ranging from 0.68 to 0.75 at 1 and 2 years after index dates. Risk estimates tended to underestimate true risk. The cumulative incidences of medication prescriptions at 1 and 2 years were 0.35 and 0.48, respectively, among 1,673 patients flagged by the model. The cumulative incidences in the same number of randomly sampled subjects were 0.12 and 0.19, and in patients over 50 years with the highest body mass indices, they were 0.22 and 0.34. We demonstrate that prognostic algorithms can guide pre-emptive pharmacogenetic testing toward those likely to benefit from it. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. STFM's National Clerkship Curriculum: CERA reveals impact, clerkship director needs.

    PubMed

    Cochella, Susan; Steiner, Beat D; Clinch, C Randall; WinklerPrins, Vince

    2014-06-01

    Consistency is needed in family medicine clerkships nationwide. The Society of Teachers of Family Medicine's (STFM) National Clerkship Curriculum (NCC) and supporting NCC website have been developed to address this need. A survey was used to measure these tools' effect and guide future improvements. The Council of Academic Family Medicine's (CAFM) Educational Research Alliance (CERA) 2012 survey of clerkship directors (CD) was used to answer two research questions: (1) To what extent are clerkships teaching the minimum core curriculum? and (2) What resources do clerkship directors identify as important in their role? The survey response rate was 66% (88/134). Ninety-two percent of these CDs are aware of the NCC, 74% report having visited the NCC website, and 71% plan to visit it more than once per year in the future. A total of 21.6% strongly agree that their clerkship content matches the NCC. CDs rate the quality of materials on the website as high and place greatest value on materials that can be downloaded and adapted to their clerkships. STFM's NCC website and materials are familiar to CDs although only one in five state their clerkship curriculum matches the NCC minimum core curriculum. The NCC editorial board needs to better understand why so few teach curriculum that closely matches the minimum core. Continued outreach to CDs can answer this question and improve our ability to support CDs as they incorporate the NCC into family medicine clerkships.

  14. Development of an Exploration-Class Cascade Distillation System: Flight Like Prototype Design Status

    NASA Technical Reports Server (NTRS)

    Sargusingh, Miriam C.; Callahan, Michael R.

    2016-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. One such technology is the Cascade Distillation System (CDS) a multi-stage vacuum rotary distiller system designed to recover water in a microgravity environment. The CDS provides a similar function to the state of the art (SOA) vapor compressor distiller (VCD) currently employed on the International Space Station, but its control scheme and ancillary components are judged to be more straightforward and simpler to implement into a more reliable and efficient system. Through the Advanced Exploration Systems (AES) Life Support Systems (LSS) Project, the NASA Johnson Space Center (JSC) in collaboration with Honeywell International is developing a second generation flight forward prototype (CDS 2.0). A preliminary design fo the CDS 2.0 was presented to the project in September 2014. Following this review, detailed design of the system continued. The existing ground test prototype was used as a platform to demonstrate key 2.0 design and operational concepts to support this effort and mitigate design risk. A volumetric prototype was also developed to evaluate the packaging design for operability and maintainability. The updated system design was reviewed by the AES LSS Project and other key stakeholders in September 2015. This paper details the status of the CDS 2.0 design.

  15. Cascade Distillation System Design for Safety and Mission Assurance

    NASA Technical Reports Server (NTRS)

    Sargusingh, Miriam J.; Callahan, Michael R.

    2015-01-01

    Per the NASA Human Health, Life Support and Habitation System Technology Area 06 report "crewed missions venturing beyond Low-Earth Orbit (LEO) will require technologies with improved reliability, reduced mass, self-sufficiency, and minimal logistical needs as an emergency or quick-return option will not be feasible." To meet this need, the development team of the second generation Cascade Distillation System (CDS 2.0) opted a development approach that explicitely incorporate consideration of safety, mission assurance, and autonomy. The CDS 2.0 prelimnary design focused on establishing a functional baseline that meets the CDS core capabilities and performance. The critical design phase is now focused on incorporating features through a deliberative process of establishing the systems failure modes and effects, identifying mitigative strategies, and evaluating the merit of the proposed actions through analysis and test. This paper details results of this effort on the CDS 2.0 design.

  16. Cascade Distillation System Design for Safety and Mission Assurance

    NASA Technical Reports Server (NTRS)

    Sarguisingh, Miriam; Callahan, Michael R.; Okon, Shira

    2015-01-01

    Per the NASA Human Health, Life Support and Habitation System Technology Area 06 report "crewed missions venturing beyond Low-Earth Orbit (LEO) will require technologies with improved reliability, reduced mass, self-sufficiency, and minimal logistical needs as an emergency or quick-return option will not be feasible".1 To meet this need, the development team of the second generation Cascade Distillation System (CDS 2.0) chose a development approach that explicitly incorporate consideration of safety, mission assurance, and autonomy. The CDS 2.0 preliminary design focused on establishing a functional baseline that meets the CDS core capabilities and performance. The critical design phase is now focused on incorporating features through a deliberative process of establishing the systems failure modes and effects, identifying mitigation strategies, and evaluating the merit of the proposed actions through analysis and test. This paper details results of this effort on the CDS 2.0 design.

  17. A Fuzzy-Decision Based Approach for Composite Event Detection in Wireless Sensor Networks

    PubMed Central

    Zhang, Shukui; Chen, Hao; Zhu, Qiaoming

    2014-01-01

    The event detection is one of the fundamental researches in wireless sensor networks (WSNs). Due to the consideration of various properties that reflect events status, the Composite event is more consistent with the objective world. Thus, the research of the Composite event becomes more realistic. In this paper, we analyze the characteristics of the Composite event; then we propose a criterion to determine the area of the Composite event and put forward a dominating set based network topology construction algorithm under random deployment. For the unreliability of partial data in detection process and fuzziness of the event definitions in nature, we propose a cluster-based two-dimensional τ-GAS algorithm and fuzzy-decision based composite event decision mechanism. In the case that the sensory data of most nodes are normal, the two-dimensional τ-GAS algorithm can filter the fault node data effectively and reduce the influence of erroneous data on the event determination. The Composite event judgment mechanism which is based on fuzzy-decision holds the superiority of the fuzzy-logic based algorithm; moreover, it does not need the support of a huge rule base and its computational complexity is small. Compared to CollECT algorithm and CDS algorithm, this algorithm improves the detection accuracy and reduces the traffic. PMID:25136690

  18. Executable medical guidelines with Arden Syntax-Applications in dermatology and obstetrics.

    PubMed

    Seitinger, Alexander; Rappelsberger, Andrea; Leitich, Harald; Binder, Michael; Adlassnig, Klaus-Peter

    2016-08-12

    Clinical decision support systems (CDSSs) are being developed to assist physicians in processing extensive data and new knowledge based on recent scientific advances. Structured medical knowledge in the form of clinical alerts or reminder rules, decision trees or tables, clinical protocols or practice guidelines, score algorithms, and others, constitute the core of CDSSs. Several medical knowledge representation and guideline languages have been developed for the formal computerized definition of such knowledge. One of these languages is Arden Syntax for Medical Logic Systems, an International Health Level Seven (HL7) standard whose development started in 1989. Its latest version is 2.10, which was presented in 2014. In the present report we discuss Arden Syntax as a modern medical knowledge representation and processing language, and show that this language is not only well suited to define clinical alerts, reminders, and recommendations, but can also be used to implement and process computerized medical practice guidelines. This section describes how contemporary software such as Java, server software, web-services, XML, is used to implement CDSSs based on Arden Syntax. Special emphasis is given to clinical decision support (CDS) that employs practice guidelines as its clinical knowledge base. Two guideline-based applications using Arden Syntax for medical knowledge representation and processing were developed. The first is a software platform for implementing practice guidelines from dermatology. This application employs fuzzy set theory and logic to represent linguistic and propositional uncertainty in medical data, knowledge, and conclusions. The second application implements a reminder system based on clinically published standard operating procedures in obstetrics to prevent deviations from state-of-the-art care. A to-do list with necessary actions specifically tailored to the gestational week/labor/delivery is generated. Today, with the latest versions of Arden Syntax and the application of contemporary software development methods, Arden Syntax has become a powerful and versatile medical knowledge representation and processing language, well suited to implement a large range of CDSSs, including clinical-practice-guideline-based CDSSs. Moreover, such CDS is provided and can be shared as a service by different medical institutions, redefining the sharing of medical knowledge. Arden Syntax is also highly flexible and provides developers the freedom to use up-to-date software design and programming patterns for external patient data access. Copyright © 2016. Published by Elsevier B.V.

  19. Decoupling interface effect on the phase stability of CdS thin films by van der Waals heteroepitaxy

    NASA Astrophysics Data System (ADS)

    Sun, Xin; Wang, Yiping; Seewald, Lucas J.; Chen, Zhizhong; Shi, Jian; Washington, Morris A.; Lu, Toh-Ming

    2017-01-01

    Wurtzite (W) and zinc-blende (ZB) polytypism has long been observed in epitaxial CdS thin films. The present work, based on van der Waals epitaxial CdS thin films, is an attempt to explain which crystal modification, W or ZB, is favored under different growth conditions. In this van der Waals epitaxy system where the substrate influence is considered weak, it is found that the substrate temperature plays a crucial role in determining the crystal modification of CdS, that is, W and ZB CdS are more stable at low and high ends of substrate temperature, respectively. We attribute this temperature effect to the entropy difference (SW < SZB), a conclusion well supported by the thermodynamic hard sphere model formulation of the entropy difference between hexagonal close-packed and face-centered cubic structures. By summarizing other works, we find that the entropy difference model can also be applied to large mismatched (≳3%) CdS-substrate chemical epitaxy systems but not for small mismatched (≲3%) ones. In the latter case, the energy benefit in terms of high density of bonding contributed by the substrate-film interface is believed to be too overwhelming for the intrinsic entropy difference to overcome. Furthermore, the deposition rate is found to affect the crystalline quality and strain level in CdS films but not the crystal modification of the CdS films. Last, Raman and photoluminescence spectroscopies reveal the strain behaviors in the films. The phase change from W to ZB CdS is well-correlated with the observed peak shifts in Raman and photoluminescence spectroscopies.

  20. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial

    PubMed Central

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-01-01

    Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage and was admitted to hospital. Interpretation Transbronchial needle aspiration guided by endobronchial ultrasound should be considered as the initial investigation for patients with suspected lung cancer, because it reduces the time to treatment decision compared with conventional diagnosis and staging techniques. Funding UK Medical Research Council. PMID:25660225

  1. Is there cardiac risk in panic disorder? An updated systematic review.

    PubMed

    Caldirola, Daniela; Schruers, Koen R; Nardi, Antonio E; De Berardis, Domenico; Fornaro, Michele; Perna, Giampaolo

    2016-04-01

    The recognized relationship between panic disorder (PD) and cardiac disorders (CDs) is not unequivocal. We reviewed the association between PD and coronary artery disease (CAD), arrhythmias, cardiomyopathies, and sudden cardiac death. We undertook an updated systematic review, according to PRISMA guidelines. Relevant studies dating from January 1, 2000, to December 31, 2014, were identified using the PubMed database and a review of bibliographies. The psychiatric and cardiac diagnostic methodology used in each study was then to very selective inclusion criteria. Of 3044 studies, 14 on CAD, 2 on cardiomyopathies, and 1 on arrhythmias were included. Overall, the studies supported a panic-CAD association. Furthermore, in some of the studies finding no association between current full-blown PD and CAD, a broader susceptibility to panic, manifesting as past PD, current agoraphobia, or subthreshold panic symptoms, appeared to be relevant to the development of CAD. Preliminary data indicated associations between panic, arrhythmias, and cardiomyopathies. The studies were largely cross-sectional and conducted in cardiological settings. Only a few included blind settings. The clinical conditions of patients with CDs and the qualifications of raters of psychiatric diagnoses were highly heterogeneous. CDs other than CAD had been insufficiently investigated. Our review supported a relationship between PD and CDs. Given the available findings and the involvement of the cardiorespiratory system in the pathophysiology of PD, an in-depth investigation into the panic-CDs association is highly recommended. This should contribute to improved treatment and prevention of cardiac events and/or mortality, linked to PD. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Engineering a mobile health tool for resource-poor settings to assess and manage cardiovascular disease risk: SMARThealth study.

    PubMed

    Raghu, Arvind; Praveen, Devarsetty; Peiris, David; Tarassenko, Lionel; Clifford, Gari

    2015-04-29

    The incidence of chronic diseases in low- and middle-income countries is rapidly increasing both in urban and rural regions. A major challenge for health systems globally is to develop innovative solutions for the prevention and control of these diseases. This paper discusses the development and pilot testing of SMARTHealth, a mobile-based, point-of-care Clinical Decision Support (CDS) tool to assess and manage cardiovascular disease (CVD) risk in resource-constrained settings. Through pilot testing, the preliminary acceptability, utility, and efficiency of the CDS tool was obtained. The CDS tool was part of an mHealth system comprising a mobile application that consisted of an evidence-based risk prediction and management algorithm, and a server-side electronic medical record system. Through an agile development process and user-centred design approach, key features of the mobile application that fitted the requirements of the end users and environment were obtained. A comprehensive analytics framework facilitated a data-driven approach to investigate four areas, namely, system efficiency, end-user variability, manual data entry errors, and usefulness of point-of-care management recommendations to the healthcare worker. A four-point Likert scale was used at the end of every risk assessment to gauge ease-of-use of the system. The system was field-tested with eleven village healthcare workers and three Primary Health Centre doctors, who screened a total of 292 adults aged 40 years and above. 34% of participants screened by health workers were identified by the CDS tool to be high CVD risk and referred to a doctor. In-depth analysis of user interactions found the CDS tool feasible for use and easily integrable into the workflow of healthcare workers. Following completion of the pilot, further technical enhancements were implemented to improve uptake of the mHealth platform. It will then be evaluated for effectiveness and cost-effectiveness in a cluster randomized controlled trial involving 54 southern Indian villages and over 16000 individuals at high CVD risk. An evidence-based CVD risk prediction and management tool was used to develop an mHealth platform in rural India for CVD screening and management with proper engagement of health care providers and local communities. With over a third of screened participants being high risk, there is a need to demonstrate the clinical impact of the mHealth platform so that it could contribute to improved CVD detection in high risk low resource settings.

  3. The hidden economic burden of air pollution-related morbidity: evidence from the Aphekom project.

    PubMed

    Chanel, Olivier; Perez, Laura; Künzli, Nino; Medina, Sylvia

    2016-12-01

    Public decision-makers commonly use health impact assessments (HIA) to quantify the impacts of various regulation policies. However, standard HIAs do not consider that chronic diseases (CDs) can be both caused and exacerbated by a common factor, and generally focus on exacerbations. As an illustration, exposure to near road traffic-related pollution (NRTP) may affect the onset of CDs, and general ambient or urban background air pollution (BP) may exacerbate these CDs. We propose a comprehensive HIA that explicitly accounts for both the acute effects and the long-term effects, making it possible to compute the overall burden of disease attributable to air pollution. A case study applies the two HIA methods to two CDs-asthma in children and coronary heart disease (CHD) in adults over 65-for ten European cities, totaling 1.89 million 0-17-year-old children and 1.85 million adults aged 65 and over. We compare the current health effects with those that might, hypothetically, be obtained if exposure to NRTP was equally low for those living close to busy roads as it is for those living farther away, and if annual mean concentrations of both PM 10 and NO 2 -taken as markers of general urban air pollution-were no higher than 20 μg/m 3 . Returning an assessment of € 0.55 million (95 % CI 0-0.95), the HIA based on acute effects alone accounts for only about 6.2 % of the annual hospitalization burden computed with the comprehensive method [€ 8.81 million (95 % CI 3-14.4)], and for about 0.15 % of the overall economic burden of air pollution-related CDs [€ 370 million (95 % CI 106-592)]. Morbidity effects thus impact the health system more directly and strongly than previously believed. These findings may clarify the full extent of benefits from any public health or environmental policy involving CDs due to and exacerbated by a common factor.

  4. The Virtual Climate Data Server (vCDS): An iRODS-Based Data Management Software Appliance Supporting Climate Data Services and Virtualization-as-a-Service in the NASA Center for Climate Simulation

    NASA Technical Reports Server (NTRS)

    Schnase, John L.; Tamkin, Glenn S.; Ripley, W. David III; Stong, Savannah; Gill, Roger; Duffy, Daniel Q.

    2012-01-01

    Scientific data services are becoming an important part of the NASA Center for Climate Simulation's mission. Our technological response to this expanding role is built around the concept of a Virtual Climate Data Server (vCDS), repetitive provisioning, image-based deployment and distribution, and virtualization-as-a-service. The vCDS is an iRODS-based data server specialized to the needs of a particular data-centric application. We use RPM scripts to build vCDS images in our local computing environment, our local Virtual Machine Environment, NASA s Nebula Cloud Services, and Amazon's Elastic Compute Cloud. Once provisioned into one or more of these virtualized resource classes, vCDSs can use iRODS s federation capabilities to create an integrated ecosystem of managed collections that is scalable and adaptable to changing resource requirements. This approach enables platform- or software-asa- service deployment of vCDS and allows the NCCS to offer virtualization-as-a-service: a capacity to respond in an agile way to new customer requests for data services.

  5. Computerized Design Synthesis (CDS), A database-driven multidisciplinary design tool

    NASA Technical Reports Server (NTRS)

    Anderson, D. M.; Bolukbasi, A. O.

    1989-01-01

    The Computerized Design Synthesis (CDS) system under development at McDonnell Douglas Helicopter Company (MDHC) is targeted to make revolutionary improvements in both response time and resource efficiency in the conceptual and preliminary design of rotorcraft systems. It makes the accumulated design database and supporting technology analysis results readily available to designers and analysts of technology, systems, and production, and makes powerful design synthesis software available in a user friendly format.

  6. [Prosody, speech input and language acquisition].

    PubMed

    Jungheim, M; Miller, S; Kühn, D; Ptok, M

    2014-04-01

    In order to acquire language, children require speech input. The prosody of the speech input plays an important role. In most cultures adults modify their code when communicating with children. Compared to normal speech this code differs especially with regard to prosody. For this review a selective literature search in PubMed and Scopus was performed. Prosodic characteristics are a key feature of spoken language. By analysing prosodic features, children gain knowledge about underlying grammatical structures. Child-directed speech (CDS) is modified in a way that meaningful sequences are highlighted acoustically so that important information can be extracted from the continuous speech flow more easily. CDS is said to enhance the representation of linguistic signs. Taking into consideration what has previously been described in the literature regarding the perception of suprasegmentals, CDS seems to be able to support language acquisition due to the correspondence of prosodic and syntactic units. However, no findings have been reported, stating that the linguistically reduced CDS could hinder first language acquisition.

  7. Evaluating the effect of a web-based quality improvement system with feedback and outreach visits on guideline concordance in the field of cardiac rehabilitation: rationale and study protocol.

    PubMed

    van Engen-Verheul, Mariëtte M; de Keizer, Nicolette F; van der Veer, Sabine N; Kemps, Hareld M C; Scholte op Reimer, Wilma J M; Jaspers, Monique W M; Peek, Niels

    2014-12-31

    Implementation of clinical practice guidelines into daily care is hampered by a variety of barriers related to professional knowledge and collaboration in teams and organizations. To improve guideline concordance by changing the clinical decision-making behavior of professionals, computerized decision support (CDS) has been shown to be one of the most effective instruments. However, to address barriers at the organizational level, additional interventions are needed. Continuous monitoring and systematic improvement of quality are increasingly used to achieve change at this level in complex health care systems. The study aims to assess the effectiveness of a web-based quality improvement (QI) system with indicator-based performance feedback and educational outreach visits to overcome organizational barriers for guideline concordance in multidisciplinary teams in the field of cardiac rehabilitation (CR). A multicenter cluster-randomized trial with a balanced incomplete block design will be conducted in 18 Dutch CR clinics using an electronic patient record with CDS at the point of care. The intervention consists of (i) periodic performance feedback on quality indicators for CR and (ii) educational outreach visits to support local multidisciplinary QI teams focussing on systematically improving the care they provide. The intervention is supported by a web-based system which provides an overview of the feedback and facilitates development and monitoring of local QI plans. The primary outcome will be concordance to national CR guidelines with respect to the CR needs assessment and therapy indication procedure. Secondary outcomes are changes in performance of CR clinics as measured by structure, process and outcome indicators, and changes in practice variation on these indicators. We will also conduct a qualitative process evaluation (concept-mapping methodology) to assess experiences from participating CR clinics and to gain insight into factors which influence the implementation of the intervention. To our knowledge, this will be the first study to evaluate the effect of providing performance feedback with a web-based system that incorporates underlying QI concepts. The results may contribute to improving CR in the Netherlands, increasing knowledge on facilitators of guideline implementation in multidisciplinary health care teams and identifying success factors of multifaceted feedback interventions. NTR3251.

  8. Redesign of a computerized clinical reminder for colorectal cancer screening: a human-computer interaction evaluation

    PubMed Central

    2011-01-01

    Background Based on barriers to the use of computerized clinical decision support (CDS) learned in an earlier field study, we prototyped design enhancements to the Veterans Health Administration's (VHA's) colorectal cancer (CRC) screening clinical reminder to compare against the VHA's current CRC reminder. Methods In a controlled simulation experiment, 12 primary care providers (PCPs) used prototypes of the current and redesigned CRC screening reminder in a within-subject comparison. Quantitative measurements were based on a usability survey, workload assessment instrument, and workflow integration survey. We also collected qualitative data on both designs. Results Design enhancements to the VHA's existing CRC screening clinical reminder positively impacted aspects of usability and workflow integration but not workload. The qualitative analysis revealed broad support across participants for the design enhancements with specific suggestions for improving the reminder further. Conclusions This study demonstrates the value of a human-computer interaction evaluation in informing the redesign of information tools to foster uptake, integration into workflow, and use in clinical practice. PMID:22126324

  9. Cadmium sulfide quantum dots supported on gallium and indium oxide for visible-light-driven hydrogen evolution from water.

    PubMed

    Pan, Yun-xiang; Zhuang, Huaqiang; Hong, Jindui; Fang, Zheng; Liu, Hai; Liu, Bin; Huang, Yizhong; Xu, Rong

    2014-09-01

    In this work, CdS quantum dots (QDs) supported on Ga2O3 and In2O3 are applied for visible-light-driven H2 evolution from aqueous solutions that contain lactic acid. With Pt as the cocatalyst, the H2 evolution rates on CdS/Pt/Ga2O3 and CdS/Pt/In2O3 are as high as 995.8 and 1032.2 μmol h(-1), respectively, under visible light (λ>420 nm) with apparent quantum efficiencies of 43.6 and 45.3% obtained at 460 nm, respectively. These are much higher than those on Pt/CdS (108.09 μmol h(-1)), Pt/Ga2O3 (0.12 μmol h(-1)), and Pt/In2O3 (0.05 μmol h(-1)). The photocatalysts have been characterized thoroughly and their band structures and photocurrent responses have been measured. The band alignment between the CdS QDs and In2O3 can lead to interfacial charge separation, which cannot occur between the CdS QDs and Ga2O3. Among the various possible factors that contribute to the high H2 evolution rates on CdS/Pt/oxide, the surface properties of the metal oxides play important roles, which include (i) the anchoring of CdS QDs and Pt nanoparticles for favorable interactions and (ii) the efficient trapping of photogenerated electrons from the CdS QDs because of surface defects (such as oxygen defects) based on photoluminescence and photocurrent studies. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. pXRF analyses of Louise Herreshoff's paintings in relation to CdS and other pigment degradation issues

    NASA Astrophysics Data System (ADS)

    Uffelman, Erich S.; Hobbs, Patricia A.; Barisas, Derek A. G.; Mass, Jennifer L.

    2013-04-01

    Portable X-ray Fluorescence Spectrometry (pXRF) was used to survey 33 works in Washington and Lee University's collection of Louise Herreshoff's paintings. This work was done both to support a condition assessment of the paintings and their pigments and to determine which paintings might be appropriate for further study in the context of ongoing key synchrotron research into the degradation mechanisms of cadmium sulfide yellow pigment (CdS).

  11. Development of an Exploration-Class Cascade Distillation System: Flight Like Prototype Preliminary Design

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Sargusingh, Miriam J.

    2015-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. One such technology is the Cascade Distillation System (CDS) a multi-stage vacuum rotary distiller system designed to recover water in a microgravity environment. Its rotating cascading distiller operates similarly to the state of the art (SOA) vapor compressor distiller (VCD), but its control scheme and ancillary components are judged to be straightforward and simpler to implement into a successful design. Through the Advanced Exploration Systems (AES) Life Support Systems (LSS) Project, the NASA Johnson Space Center (JSC) in collaboration with Honeywell International is developing a second generation flight forward prototype (CDS 2.0). The key objectives for the CDS 2.0 design task is to provide a flight forward ground prototype that demonstrates improvements over the SOA system in the areas of increased reliability and robustness, and reduced mass, power and volume. It will also incorporate exploration-class automation. The products of this task are a preliminary flight system design and a high fidelity prototype of an exploration class CDS. These products will inform the design and development of the third generation CDS which is targeted for on-orbit DTO. This paper details the preliminary design of the CDS 2.0.

  12. NASA Cloud-Based Climate Data Services

    NASA Astrophysics Data System (ADS)

    McInerney, M. A.; Schnase, J. L.; Duffy, D. Q.; Tamkin, G. S.; Strong, S.; Ripley, W. D., III; Thompson, J. H.; Gill, R.; Jasen, J. E.; Samowich, B.; Pobre, Z.; Salmon, E. M.; Rumney, G.; Schardt, T. D.

    2012-12-01

    Cloud-based scientific data services are becoming an important part of NASA's mission. Our technological response is built around the concept of specialized virtual climate data servers, repetitive cloud provisioning, image-based deployment and distribution, and virtualization-as-a-service (VaaS). A virtual climate data server (vCDS) is an Open Archive Information System (OAIS) compliant, iRODS-based data server designed to support a particular type of scientific data collection. iRODS is data grid middleware that provides policy-based control over collection-building, managing, querying, accessing, and preserving large scientific data sets. We have deployed vCDS Version 1.0 in the Amazon EC2 cloud using S3 object storage and are using the system to deliver a subset of NASA's Intergovernmental Panel on Climate Change (IPCC) data products to the latest CentOS federated version of Earth System Grid Federation (ESGF), which is also running in the Amazon cloud. vCDS-managed objects are exposed to ESGF through FUSE (Filesystem in User Space), which presents a POSIX-compliant filesystem abstraction to applications such as the ESGF server that require such an interface. A vCDS manages data as a distinguished collection for a person, project, lab, or other logical unit. A vCDS can manage a collection across multiple storage resources using rules and microservices to enforce collection policies. And a vCDS can federate with other vCDSs to manage multiple collections over multiple resources, thereby creating what can be thought of as an ecosystem of managed collections. With the vCDS approach, we are trying to enable the full information lifecycle management of scientific data collections and make tractable the task of providing diverse climate data services. In this presentation, we describe our approach, experiences, lessons learned, and plans for the future.; (A) vCDS/ESG system stack. (B) Conceptual architecture for NASA cloud-based data services.

  13. Liquidity crisis detection: An application of log-periodic power law structures to default prediction

    NASA Astrophysics Data System (ADS)

    Wosnitza, Jan Henrik; Denz, Cornelia

    2013-09-01

    We employ the log-periodic power law (LPPL) to analyze the late-2000 financial crisis from the perspective of critical phenomena. The main purpose of this study is to examine whether LPPL structures in the development of credit default swap (CDS) spreads can be used for default classification. Based on the different triggers of Bear Stearns’ near bankruptcy during the late-2000 financial crisis and Ford’s insolvency in 2009, this study provides a quantitative description of the mechanism behind bank runs. We apply the Johansen-Ledoit-Sornette (JLS) positive feedback model to explain the rise of financial institutions’ CDS spreads during the global financial crisis 2007-2009. This investigation is based on CDS spreads of 40 major banks over the period from June 2007 to April 2009 which includes a significant CDS spread increase. The qualitative data analysis indicates that the CDS spread variations have followed LPPL patterns during the global financial crisis. Furthermore, the univariate classification performances of seven LPPL parameters as default indicators are measured by Mann-Whitney U tests. The present study supports the hypothesis that discrete scale-invariance governs the dynamics of financial markets and suggests the application of new and fast updateable default indicators to capture the buildup of long-range correlations between creditors.

  14. Understanding misfit strain releasing mechanisms via molecular dynamics simulations of CdTe growth on {112}zinc-blende CdS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Xiaowang; Chavez, Jose J.; Almeida, Sergio F.

    Molecular dynamics simulations have been used to analyse microstructures of CdTe films grown on {112} surfaces of zinc-blende CdS. Interestingly, CdTe films grow in <331> orientations as opposed to <112> epitaxial orientations. At the CdTe-{331}/CdS-{112} interface, however, there exists an axis that is parallel to the <110> orientation of both CdS and CdTe. It is the direction orthogonal to this <110> that becomes different, being <116> for CdTe and <111> for CdS, respectively. Missing CdTe-{110} planes are found along the <110> axis, suggesting that the misfit strain is released by the conventional misfit dislocation mechanism along this axis. In themore » orthogonal axis, the misfit strain is found to be more effectively released by the new grain orientation mechanism. Our finding is supported by literature experimental observations of the change of growth direction when Cd 0.96Zn 0.04Te films are deposited on GaAs. Lastly the analyses of energetics clearly demonstrate the cause for the formation of the new orientation, and the insights gained from our studies can help understand the grain structures experimentally observed in lattice mismatched systems.« less

  15. Understanding misfit strain releasing mechanisms via molecular dynamics simulations of CdTe growth on {112}zinc-blende CdS

    DOE PAGES

    Zhou, Xiaowang; Chavez, Jose J.; Almeida, Sergio F.; ...

    2016-07-25

    Molecular dynamics simulations have been used to analyse microstructures of CdTe films grown on {112} surfaces of zinc-blende CdS. Interestingly, CdTe films grow in <331> orientations as opposed to <112> epitaxial orientations. At the CdTe-{331}/CdS-{112} interface, however, there exists an axis that is parallel to the <110> orientation of both CdS and CdTe. It is the direction orthogonal to this <110> that becomes different, being <116> for CdTe and <111> for CdS, respectively. Missing CdTe-{110} planes are found along the <110> axis, suggesting that the misfit strain is released by the conventional misfit dislocation mechanism along this axis. In themore » orthogonal axis, the misfit strain is found to be more effectively released by the new grain orientation mechanism. Our finding is supported by literature experimental observations of the change of growth direction when Cd 0.96Zn 0.04Te films are deposited on GaAs. Lastly the analyses of energetics clearly demonstrate the cause for the formation of the new orientation, and the insights gained from our studies can help understand the grain structures experimentally observed in lattice mismatched systems.« less

  16. Boosting standard order sets utilization through clinical decision support.

    PubMed

    Li, Haomin; Zhang, Yinsheng; Cheng, Haixia; Lu, Xudong; Duan, Huilong

    2013-01-01

    Well-designed standard order sets have the potential to integrate and coordinate care by communicating best practices through multiple disciplines, levels of care, and services. However, there are several challenges which certainly affected the benefits expected from standard order sets. To boost standard order sets utilization, a problem-oriented knowledge delivery solution was proposed in this study to facilitate access of standard order sets and evaluation of its treatment effect. In this solution, standard order sets were created along with diagnostic rule sets which can trigger a CDS-based reminder to help clinician quickly discovery hidden clinical problems and corresponding standard order sets during ordering. Those rule set also provide indicators for targeted evaluation of standard order sets during treatment. A prototype system was developed based on this solution and will be presented at Medinfo 2013.

  17. Preemptive genotyping for personalized medicine: design of the right drug, right dose, right time-using genomic data to individualize treatment protocol.

    PubMed

    Bielinski, Suzette J; Olson, Janet E; Pathak, Jyotishman; Weinshilboum, Richard M; Wang, Liewei; Lyke, Kelly J; Ryu, Euijung; Targonski, Paul V; Van Norstrand, Michael D; Hathcock, Matthew A; Takahashi, Paul Y; McCormick, Jennifer B; Johnson, Kiley J; Maschke, Karen J; Rohrer Vitek, Carolyn R; Ellingson, Marissa S; Wieben, Eric D; Farrugia, Gianrico; Morrisette, Jody A; Kruckeberg, Keri J; Bruflat, Jamie K; Peterson, Lisa M; Blommel, Joseph H; Skierka, Jennifer M; Ferber, Matthew J; Black, John L; Baudhuin, Linnea M; Klee, Eric W; Ross, Jason L; Veldhuizen, Tamra L; Schultz, Cloann G; Caraballo, Pedro J; Freimuth, Robert R; Chute, Christopher G; Kullo, Iftikhar J

    2014-01-01

    To report the design and implementation of the Right Drug, Right Dose, Right Time-Using Genomic Data to Individualize Treatment protocol that was developed to test the concept that prescribers can deliver genome-guided therapy at the point of care by using preemptive pharmacogenomics (PGx) data and clinical decision support (CDS) integrated into the electronic medical record (EMR). We used a multivariate prediction model to identify patients with a high risk of initiating statin therapy within 3 years. The model was used to target a study cohort most likely to benefit from preemptive PGx testing among the Mayo Clinic Biobank participants, with a recruitment goal of 1000 patients. We used a Cox proportional hazards model with variables selected through the Lasso shrinkage method. An operational CDS model was adapted to implement PGx rules within the EMR. The prediction model included age, sex, race, and 6 chronic diseases categorized by the Clinical Classifications Software for International Classification of Diseases, Ninth Revision codes (dyslipidemia, diabetes, peripheral atherosclerosis, disease of the blood-forming organs, coronary atherosclerosis and other heart diseases, and hypertension). Of the 2000 Biobank participants invited, 1013 (51%) provided blood samples, 256 (13%) declined participation, 555 (28%) did not respond, and 176 (9%) consented but did not provide a blood sample within the recruitment window (October 4, 2012, through March 20, 2013). Preemptive PGx testing included CYP2D6 genotyping and targeted sequencing of 84 PGx genes. Synchronous real-time CDS was integrated into the EMR and flagged potential patient-specific drug-gene interactions and provided therapeutic guidance. This translational project provides an opportunity to begin to evaluate the impact of preemptive sequencing and EMR-driven genome-guided therapy. These interventions will improve understanding and implementation of genomic data in clinical practice. Copyright © 2014 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  18. Sustained User Engagement in Health Information Technology: The Long Road from Implementation to System Optimization of Computerized Physician Order Entry and Clinical Decision Support Systems for Prescribing in Hospitals in England.

    PubMed

    Cresswell, Kathrin M; Lee, Lisa; Mozaffar, Hajar; Williams, Robin; Sheikh, Aziz

    2017-10-01

    To explore and understand approaches to user engagement through investigating the range of ways in which health care workers and organizations accommodated the introduction of computerized physician order entry (CPOE) and computerized decision support (CDS) for hospital prescribing. Six hospitals in England, United Kingdom. Qualitative case study. We undertook qualitative semi-structured interviews, non-participant observations of meetings and system use, and collected organizational documents over three time periods from six hospitals. Thematic analysis was initially undertaken within individual cases, followed by cross-case comparisons. We conducted 173 interviews, conducted 24 observations, and collected 17 documents between 2011 and 2015. We found that perceived individual and safety benefits among different user groups tended to facilitate engagement in some, while other less engaged groups developed resistance and unsanctioned workarounds if systems were perceived to be inadequate. We identified both the opportunity and need for sustained engagement across user groups around system enhancement (e.g., through customizing software) and the development of user competencies and effective use. There is an urgent need to move away from an episodic view of engagement focused on the preimplementation phase, to more continuous holistic attempts to engage with and respond to end-users. © Health Research and Educational Trust.

  19. Ag plasmonic nanostructures and a novel gel electrolyte in a high efficiency TiO2/CdS solar cell.

    PubMed

    Kumar, P Naresh; Deepa, Melepurath; Srivastava, Avanish Kumar

    2015-04-21

    A novel photoanode architecture with plasmonic silver (Ag) nanostructures embedded in titania (TiO2), which served as the wide band gap semiconducting support and CdS quantum dots (QDs), as light absorbers, is presented. Ag nanostructures were prepared by a polyol method and are comprised of clumps of nanorods, 15-35 nm wide, interspersed with globular nanoparticles and they were characterized by a face centered cubic lattice. Optimization of Ag nanostructures was achieved on the basis of a superior power conversion efficiency (PCE) obtained for the cell with a Ag/TiO2/CdS electrode encompassing a mixed morphology of Ag nano-rods and particles, relative to analogous cells with either Ag nanoparticles or Ag nanorods. Interfacial charge transfer kinetics was unraveled by fluorescence quenching and lifetime studies. Ag nanostructures improve the light harvesting ability of the TiO2/CdS photoanode via (a) plasmonic and scattering effects, which induce both near- and far-field enhancements which translate to higher photocurrent densities and (b) charging effects, whereby, photoexcited electron transfer from TiO2 to Ag is facilitated by Fermi level equilibration. Owing to the spectacular ability of Ag nanostructures to increase light absorption, a greatly increased PCE of 4.27% and a maximum external quantum efficiency of 55% (at 440 nm) was achieved for the cell based on Ag/TiO2/CdS, greater by 42 and 66%, respectively, compared to the TiO2/CdS based cell. In addition, the liquid S(2-) electrolyte was replaced by a S(2-) gel containing fumed silica, and the redox potential, conductivity and p-type conduction of the two were deduced to be comparable. Although the gel based cells showed diminished solar cell performances compared to their liquid counterparts, nonetheless, the Ag/TiO2/CdS electrode continued to outperform the TiO2/CdS electrode. Our studies demonstrate that Ag nanostructures effectively capture a significant chunk of the electromagnetic spectrum and aid QD solar cells in delivering high power conversion efficiencies.

  20. Longitudinal adoption rates of complex decision support tools in primary care.

    PubMed

    McCullagh, Lauren; Mann, Devin; Rosen, Lisa; Kannry, Joseph; McGinn, Thomas

    2014-12-01

    Translating research findings into practice promises to standardise care. Translation includes the integration of evidence-based guidelines at the point of care, discerning the best methods to disseminate research findings and models to sustain the implementation of best practices.By applying usability testing to clinical decision support(CDS) design, overall adoption rates of 60% can be realised.What has not been examined is how long adoption rates are sustained and the characteristics associated with long-term use. We conducted secondary analysis to decipher the factors impacting sustained use of CD Stools. This study was a secondary data analysis from a clinical trial conducted at an academic institution in New York City. Study data was identified patients electronic health records (EHR). The trial was to test the implementation of an integrated clinical prediction rule(iCPR) into the EHR. The primary outcome variable was iCPR tool acceptance of the tool. iCPR tool completion and iCPR smartest completion were additional outcome variables of interest. The secondary aim was to examine user characteristics associated with iCPR tool use in later time periods. Characteristics of interest included age, resident year, use of electronic health records (yes/no) and use of best practice alerts (BPA) (yes/no). Generalised linear mixed models (GLiMM) were used to compare iCPR use over time for each outcome of interest: namely, iCPR acceptance, iCPR completion and iCPR smartset completion.GLiMM was also used to examine resident characteristics associated with iCPR tool use in later time periods; specifically, intermediate and long-term (ie, 90+days). The tool was accepted, on average, 82.18% in the first 90 days (short-term period). The use decreases to 56.07% and 45.61% in intermediate and long-term time periods, respectively. There was a significant association between iCPR tool completion and time periods(p<0.0001). There was no significant difference in iCPR tool completion between resident encounters in the intermediate and long-term periods (p<0.6627). There was a significant association between iCPR smartset completion and time periods (p<0.0021). There were no significant associations between iCPR smartest completion and any of the four predictors of interest. We examined the frequencies of components of the iCPR tool being accepted over time by individual clinicians. Rates of adoption of the different components of the tool decreased substantially over time. The data suggest that over time and prolonged exposure to CDS tools, providers are less likely to utilise the tool. It is not clear if it is fatigue with the CDS tool, acquired knowledge of the clinical prediction rule, or gained clinical experience and gestalt that are influencing adoption rates. Further analysis of individual adoption rates over time and the impact it has on clinical outcomes should be conducted.

  1. Assessment of the management factors that influence the development of preventive care in the New South Wales public dental service.

    PubMed

    Masoe, Angela V; Blinkhorn, Anthony S; Taylor, Jane; Blinkhorn, Fiona A

    2015-01-01

    Oral diseases, particularly dental caries, remain one of the most common chronic health problems for adolescents, and are a major public health concern. Public dental services in New South Wales, Australia offer free clinical care and preventive advice to all adolescents under 18 years of age, particularly those from disadvantaged backgrounds. This care is provided by dental therapists and oral health therapists (therapists). It is incumbent upon clinical directors (CDs) and health service managers (HSMs) to ensure that the appropriate clinical preventive care is offered by clinicians to all their patients. The aims of this study were to 1) explore CDs' and HSMs' perceptions of the factors that could support the delivery of preventive care to adolescents, and to 2) record the strategies they have utilized to help therapists provide preventive care to adolescents. In-depth, semistructured interviews were undertaken with 19 CDs and HSMs from across NSW local health districts. A framework matrix was used to systematically code data and enable key themes to be identified for analysis. The 19 CDs and HSMs reported that fiscal accountability and meeting performance targets impacted on the levels and types of preventive care provided by therapists. Participants suggested that professional clinical structures for continuous quality improvement should be implemented and monitored, and that an adequate workforce mix and more resources for preventive dental care activities would enhance therapists' ability to provide appropriate levels of preventive care. CDs and HSMs stated that capitalizing on the strengths of visiting pediatric dental specialists and working with local health district clinical leaders would be a practical way to improve models of preventive oral health care for adolescents. The main issue raised in this study is that preventive dentistry per se lacks strong support from the central funding agency, and that increasing prevention activities is not a simple task of changing regulations or increasing professional education.

  2. Health information technology in primary health care in developing countries: a literature review.

    PubMed Central

    Tomasi, Elaine; Facchini, Luiz Augusto; Maia, Maria de Fatima Santos

    2004-01-01

    This paper explores the debate and initiatives concerning the use of information technology (IT) in primary health care in developing countries. The literature from 1992-2002 was identified from searches of the MEDLINE, Latin American and Caribbean Health Science Literature Database (LILACS), Cochrane Library and Web of Science databases. The search identified 884 references, 350 of which were classified according to the scheme described by the Pan American Health Organization (PAHO). For the analysis of advantages, problems and perspectives of IT applications and systems, 52 articles were selected according to their potential contribution to the primary health-care processes in non-developed countries. These included: 10 on electronic patient registries (EPR), 22 on process and programmatic action evaluation and management systems (PPAEM) and 20 on clinical decision-support systems (CDS). The main advantages, limitations and perspectives are discussed. PMID:15640923

  3. Improving guideline concordance in multidisciplinary teams: preliminary results of a cluster-randomized trial evaluating the effect of a web-based audit and feedback intervention with outreach visits

    PubMed Central

    van Engen-Verheul, Mariëtte M.; Gude, Wouter T.; van der Veer, Sabine N.; Kemps, Hareld M.C.; Jaspers, Monique M.W.; de Keizer, Nicolette F.; Peek, Niels

    2015-01-01

    Despite their widespread use, audit and feedback (A&F) interventions show variable effectiveness on improving professional performance. Based on known facilitators of successful A&F interventions, we developed a web-based A&F intervention with indicator-based performance feedback, benchmark information, action planning and outreach visits. The goal of the intervention was to engage with multidisciplinary teams to overcome barriers to guideline concordance and to improve overall team performance in the field of cardiac rehabilitation (CR). To assess its effectiveness we conducted a cluster-randomized trial in 18 CR clinics (14,847 patients) already working with computerized decision support (CDS). Our preliminary results showed no increase in concordance with guideline recommendations regarding prescription of CR therapies. Future analyses will investigate whether our intervention did improve team performance on other quality indicators. PMID:26958310

  4. Rear-facing versus forward-facing child restraints: an updated assessment.

    PubMed

    McMurry, Timothy L; Arbogast, Kristy B; Sherwood, Christopher P; Vaca, Federico; Bull, Marilyn; Crandall, Jeff R; Kent, Richard W

    2018-02-01

    The National Highway Traffic Safety Administration and the American Academy of Pediatrics recommend children be placed in rear-facing child restraint systems (RFCRS) until at least age 2. These recommendations are based on laboratory biomechanical tests and field data analyses. Due to concerns raised by an independent researcher, we re-evaluated the field evidence in favour of RFCRS using the National Automotive Sampling System Crashworthiness Data System (NASS-CDS) database. Children aged 0 or 1 year old (0-23 months) riding in either rear-facing or forward-facing child restraint systems (FFCRS) were selected from the NASS-CDS database, and injury rates were compared by seat orientation using survey-weighted χ 2 tests. In order to compare with previous work, we analysed NASS-CDS years 1988-2003, and then updated the analyses to include all available data using NASS-CDS years 1988-2015. Years 1988-2015 of NASS-CDS contained 1107 children aged 0 or 1 year old meeting inclusion criteria, with 47 of these children sustaining injuries with Injury Severity Score of at least 9. Both 0-year-old and 1-year-old children in RFCRS had lower rates of injury than children in FFCRS, but the available sample size was too small for reasonable statistical power or to allow meaningful regression controlling for covariates. Non-US field data and laboratory tests support the recommendation that children be kept in RFCRS for as long as possible, but the US NASS-CDS field data are too limited to serve as a strong statistical basis for these recommendations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. The iron stimulon of Xylella fastidiosa includes genes for type IV pilus and colicin V-like bacteriocins.

    PubMed

    Zaini, Paulo A; Fogaça, Andréa C; Lupo, Fernanda G N; Nakaya, Helder I; Vêncio, Ricardo Z N; da Silva, Aline M

    2008-04-01

    Xylella fastidiosa is the etiologic agent of a wide range of plant diseases, including citrus variegated chlorosis (CVC), a major threat to citrus industry. The genomes of several strains of this phytopathogen were completely sequenced, enabling large-scale functional studies. DNA microarrays representing 2,608 (91.6%) coding sequences (CDS) of X. fastidiosa CVC strain 9a5c were used to investigate transcript levels during growth with different iron availabilities. When treated with the iron chelator 2,2'-dipyridyl, 193 CDS were considered up-regulated and 216 were considered down-regulated. Upon incubation with 100 microM ferric pyrophosphate, 218 and 256 CDS were considered up- and down-regulated, respectively. Differential expression for a subset of 44 CDS was further evaluated by reverse transcription-quantitative PCR. Several CDS involved with regulatory functions, pathogenicity, and cell structure were modulated under both conditions assayed, suggesting that major changes in cell architecture and metabolism occur when X. fastidiosa cells are exposed to extreme variations in iron concentration. Interestingly, the modulated CDS include those related to colicin V-like bacteriocin synthesis and secretion and to functions of pili/fimbriae. We also investigated the contribution of the ferric uptake regulator Fur to the iron stimulon of X. fastidiosa. The promoter regions of the strain 9a5c genome were screened for putative Fur boxes, and candidates were analyzed by electrophoretic mobility shift assays. Taken together, our data support the hypothesis that Fur is not solely responsible for the modulation of the iron stimulon of X. fastidiosa, and they present novel evidence for iron regulation of pathogenicity determinants.

  6. Hospital information systems: experience at the fully digitized Seoul National University Bundang Hospital.

    PubMed

    Yoo, Sooyoung; Hwang, Hee; Jheon, Sanghoon

    2016-08-01

    The different levels of health information technology (IT) adoption and its integration into hospital workflow can affect the maximization of the benefits of using of health IT. We aimed at sharing our experiences and the journey to the successful adoption of health IT over 13 years at a tertiary university hospital in South Korea. The integrated system of comprehensive applications for direct care, support care, and smart care has been implemented with the latest IT and a rich user information platform, achieving the fully digitized hospital. The users experience design methodology, barcode and radio-frequency identification (RFID) technologies, smartphone and mobile technologies, and data analytics were integrated into hospital workflow. Applications for user-centered electronic medical record (EMR) and clinical decision support (CDS), closed loop medication administration (CLMA), mobile EMR and dashboard system for care coordination, clinical data warehouse (CDW) system, and patient engagement solutions were designed and developed to improve quality of care, work efficiency, and patient safety. We believe that comprehensive electronic health record systems and patient-centered smart hospital applications will go a long way in ensuring seamless patient care and experience.

  7. A bilaminated decellularized scaffold for islet transplantation: Structure, properties and functions in diabetic mice.

    PubMed

    Wang, Xi; Wang, Kai; Zhang, Wei; Qiang, Ming; Luo, Ying

    2017-09-01

    Ectopic transplantation of islets provides a beta cell-replacement approach that may allow the recovery of physiological regulation of the blood sugar level in patients with Type I diabetes (T1D). In development of new extrahepatic islet transplantation protocols in support of the islet engraftment, it is pivotal to develop scaffold materials with multifaceted functions to provide beneficial microenvironment, mediate host response in favor of vascularization/islet integration and maintain long-term islet function at the transplantation site. In this study, a new composite bilaminar decellularized scaffold (CDS) was fabricated with differential structural, degradation and mechanical properties by the combination of a fast-degrading porous collagen matrix and a mechanically supportive porcine pericardium. When investigated in the epididymal fat pad in syngeneic mouse models, it was shown that CDS could serve as superior scaffolds to promote islet adhesion and viability, and islet-CDS constructs also allowed rapid reversal of the hyperglycemic condition in the host. The engraftment and effects of islets were achieved at low islet numbers, accompanied by minimal adverse tissue reactions and optimal islet integration with the surrounding fat tissue. The bioactive surface, mechanical/chemical durability and biocompatibility of the CDS may all have played important roles in facilitating the engraftment of islets. Our study provided new insights into scaffold's function in the interplay of cells, materials and host tissue and the extracellular matrix-based scaffolds have potential for clinical translation in the beta cell-replacement therapy to treat T1D. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Highly efficient visible-light-driven photocatalytic hydrogen production of CdS-cluster-decorated graphene nanosheets.

    PubMed

    Li, Qin; Guo, Beidou; Yu, Jiaguo; Ran, Jingrun; Zhang, Baohong; Yan, Huijuan; Gong, Jian Ru

    2011-07-20

    The production of clean and renewable hydrogen through water splitting using photocatalysts has received much attention due to the increasing global energy crises. In this study, a high efficiency of the photocatalytic H(2) production was achieved using graphene nanosheets decorated with CdS clusters as visible-light-driven photocatalysts. The materials were prepared by a solvothermal method in which graphene oxide (GO) served as the support and cadmium acetate (Cd(Ac)(2)) as the CdS precursor. These nanosized composites reach a high H(2)-production rate of 1.12 mmol h(-1) (about 4.87 times higher than that of pure CdS nanoparticles) at graphene content of 1.0 wt % and Pt 0.5 wt % under visible-light irradiation and an apparent quantum efficiency (QE) of 22.5% at wavelength of 420 nm. This high photocatalytic H(2)-production activity is attributed predominantly to the presence of graphene, which serves as an electron collector and transporter to efficiently lengthen the lifetime of the photogenerated charge carriers from CdS nanoparticles. This work highlights the potential application of graphene-based materials in the field of energy conversion.

  9. Structural, Optical, and Electrical Properties of Cobalt-Doped CdS Quantum Dots

    NASA Astrophysics Data System (ADS)

    Thambidurai, M.; Muthukumarasamy, N.; Velauthapillai, Dhayalan; Agilan, S.; Balasundaraprabhu, R.

    2012-04-01

    In the present work, a systematic study has been carried out to understand the influence of cobalt (Co) doping on various properties of CdS nanoparticles. CdS and Co-doped CdS quantum dots have been prepared at room temperature using a chemical precipitation method without using catalysts, capping agents, or surfactants. X-ray diffraction reveals that both undoped and Co-doped CdS nanoparticles exhibit hexagonal structure without any impurity phase, and the lattice constants of CdS nanoparticles are observed to decrease slightly with increasing cobalt concentration. High-resolution transmission electron microscopy (HRTEM) shows that the particle size of CdS and 5.02% Co-doped CdS nanoparticles is in the range of 2 nm to 4 nm. The Raman spectra of Co-doped CdS nanoparticles exhibit a red-shift compared with that of bulk CdS, which may be attributed to optical phonon confinement. The optical absorption spectra of Co-doped CdS nanoparticles also exhibit a red-shift with respect to that of CdS nanoparticles. The electrical conductivity of CdS and Co-doped CdS nanoparticles is found to increase with increasing temperature and cobalt concentration.

  10. CERA: Clerkships Need National Curricula on Care Delivery, Awareness of Their NCC Gaps.

    PubMed

    Cochella, Susan; Liaw, Winston; Binienda, Juliann; Hustedde, Carol

    2016-06-01

    The Society of Teachers of Family Medicine's (STFM) National Clerkship Curriculum (NCC) was created to standardize and improve teaching of a minimum core curriculum in family medicine clerkships, promoting the Triple Aim of better care and population health at lower cost. It includes competencies all clerkships should teach and tools to support clerkship directors (CDs). This 2014 CERA survey of clerkship directors is one of several needs assessments that guide STFM's NCC Editorial Board in targeting improvements and peer-review processes. CERA's 2014 survey of CDs was sent to all 137 CDs at US and Canadian allopathic medical schools. Primary aims included: (1) Identify curricular topics of greatest need, (2) Inventory the percent of family medicine clerkships teaching each NCC topic, and (3) Determine if longitudinal or blended clerkship have unique needs. This survey also assessed use of NCC to advocate for teaching resources and collaborate with colleagues at other institutions. Ninety-one percent of CDs completed the survey. Sixty-four percent reported their clerkship covers all of the NCC minimum core, but on detailed analysis, only 1% teach all topics. CDs need curricula on care delivery topics (cost-effective approach to acute care, role of family medicine in the health care system, quality/safety, and comorbid substance abuse). Single-question assessments overestimate the percentage of clerkships teaching all of the NCC minimum core. Clerkships need national curricula on care delivery topics and tools to help them find their curricular gaps.

  11. How supportive supervision influences immunization session site practices: a quasi-experimental study in Odisha, India.

    PubMed

    Panda, Bhuputra; Pati, Sanghamitra; Nallala, Srinivas; Chauhan, Abhimanyu S; Anasuya, Anita; Som, Meena; Zodpey, Sanjay

    2015-01-01

    Routine immunization (RI) is a key child survival intervention. Ensuring acceptable standards of RI service delivery is critical for optimal outcomes. Accumulated evidences suggest that 'supportive supervision' improves the quality of health care services in general. During 2009-2010, the Government of Odisha and UNICEF jointly piloted this strategy in four districts to improve RI program outcomes. The present study aims to assess the effect of this strategy on improvement of skills and practices at immunization session sites. A quasi-experimental 'post-test only' study design was adopted to compare the opinion and practices of frontline health workers and their supervisors in four intervention districts (IDs) with two control districts (CDs). Altogether, we interviewed 111 supervisor-supervisee (health worker) pairs using semi-structured interview schedules and case vignettes. We also directly observed health workers' practices during immunization sessions at 111 sites. Data were analyzed with SPSS version 16.0. The mean knowledge score of supervisors in CDs was significantly higher than in intervention groups. Variegated responses were obtained on case vignettes. The control group performed better in solving certain hypothetically asked problems, whereas the intervention group scored better in others. Health workers in IDs gave a lower rating to their respective supervisors' knowledge, skill, and frequency of supervision. Logistics and vaccine availability were better in CDs. Notwithstanding other limitations, supportive supervision may not have independent effects on improving the quality of immunization services. Addressing systemic issues, such as the availability of essential logistics, supply chain management, timely indenting, and financial resources, could complement the supportive supervision strategy in improving immunization service delivery.

  12. Photovoltaic cell with thin CS layer

    DOEpatents

    Jordan, John F.; Albright, Scot P.

    1994-01-18

    An improved photovoltaic panel and method of forming a photovoltaic panel are disclosed for producing a high efficiency CdS/CdTe photovoltaic cell. The photovoltaic panel of the present invention is initially formed with a substantially thick Cds layer, and the effective thickness of the CdS layer is substantially reduced during regrowth to both form larger diameter CdTe crystals and substantially reduce the effective thickness of the C This invention was made with Government support under Subcontract No. ZL-7-06031-3 awarded by the Department of Energy. The Government has certain rights in this invention.

  13. Adsorption, Aggregation, and Deposition Behaviors of Carbon Dots on Minerals.

    PubMed

    Liu, Xia; Li, Jiaxing; Huang, Yongshun; Wang, Xiangxue; Zhang, Xiaodong; Wang, Xiangke

    2017-06-06

    The increased production of carbon dots (CDs) and the release and accumulation of CDs in both surface and groundwater has resulted in the increasing interest in their research. To assess the environmental behavior of CDs, the interaction between CDs and goethite was studied under different environmental conditions. Electrokinetic characterization of CDs suggested that the ζ-potential and size distribution of CDs were affected by pH and electrolyte species, indicating that these factors influenced the stability of CDs in aqueous solutions. Traditional Derjaguin-Landau-Verwey-Overbeek theory did not fit well the aggregation process of CDs. Results of the effects of pH and ionic strength suggested that electronic attraction dominated the aggregation of CDs. Compared with other minerals, hydrogen-bonding interactions and Lewis acid-base interactions contributed to the aggregation of CDs, in addition to van der Waals and electrical double-layer forces. Adsorption isotherms and microscopic Fourier transformed infrared spectroscopy indicated that chemical bonds were formed between CDs and goethite. These findings are useful to understand the interaction of CDs with minerals, as well as the potential fate and toxicity of CDs in the natural environment, especially in soils and sediments.

  14. Study of electrostatically self-assembled thin films of CdS and ZnS nanoparticle semiconductors

    NASA Astrophysics Data System (ADS)

    Suryajaya

    In this work, CdS and ZnS semiconducting colloid nanoparticles coated with organic shell, containing either SO[3-] or NH[2+] groups, were deposited as thin films using the technique of electrostatic self-assembly. The films produced were characterized with UV-vis spectroscopy and spectroscopic ellipsometry - for optical properties; atomic force microscopy (AFM) - for morphology study; mercury probe - for electrical characterisation; and photon counter - for electroluminescence study. UV-vis spectra show a substantial blue shift of the main absorption band of both CdS and ZnS, either in the form of solutions or films, with respect to the bulk materials. The calculation of nanoparticles' radii yields the value of about 1.8 nm for both CdS and ZnS.The fitting of standard ellipsometry data gave the thicknesses (d) of nanoparticle layers of around 5 nm for both CdS and ZnS which corresponds well to the size of particles evaluated from UV-vis spectral data if an additional thickness of the organic shell is taken into account. The values of refractive index (n) and extinction coefficient (k) obtained were about 2.28 and 0.7 at 633 nm wavelength, for both CdS and ZnS.Using total internal reflection (TIRE), the process of alternative deposition of poly-allylamine hydrochloride (PAH) and CdS (or ZnS) layers could be monitored in-situ. The dynamic scan shows that the adsorption kinetic of the first layer of PAH or nanoparticles was slower than that of the next layer. The fitting of TIRE spectra gavethicknesses of about 7 nm and 12 nm for CdS and ZnS, respectively. It supports the suggestion of the formation of three-dimensional aggregates of semiconductor nanoparticles intercalated with polyelectrolyte.AFM images show the formation of large aggregates of nanoparticles, about 40-50 nm, for the films deposited from original colloid solutions, while smaller aggregates, about 12-20 nm, were obtained if the colloid solutions were diluted.Current-voltage (I-V) and capacitance-frequency (C-f) measurements of polyelectrolyte/nanoparticles (CdS or ZnS) films suggest the tunnelling behaviour in the films while capacitance- voltage (C-V) and conductance-voltage (G-V) measurements suggest that these nanoparticles are conductive. The electroluminescence was detected in sandwich structures of (PAH/CdS/PAH)[N] using a photon counting detector, but not in the case of ZnS films.

  15. Anopheles gambiae genome reannotation through synthesis of ab initio and comparative gene prediction algorithms

    PubMed Central

    Li, Jun; Riehle, Michelle M; Zhang, Yan; Xu, Jiannong; Oduol, Frederick; Gomez, Shawn M; Eiglmeier, Karin; Ueberheide, Beatrix M; Shabanowitz, Jeffrey; Hunt, Donald F; Ribeiro, José MC; Vernick, Kenneth D

    2006-01-01

    Background Complete genome annotation is a necessary tool as Anopheles gambiae researchers probe the biology of this potent malaria vector. Results We reannotate the A. gambiae genome by synthesizing comparative and ab initio sets of predicted coding sequences (CDSs) into a single set using an exon-gene-union algorithm followed by an open-reading-frame-selection algorithm. The reannotation predicts 20,970 CDSs supported by at least two lines of evidence, and it lowers the proportion of CDSs lacking start and/or stop codons to only approximately 4%. The reannotated CDS set includes a set of 4,681 novel CDSs not represented in the Ensembl annotation but with EST support, and another set of 4,031 Ensembl-supported genes that undergo major structural and, therefore, probably functional changes in the reannotated set. The quality and accuracy of the reannotation was assessed by comparison with end sequences from 20,249 full-length cDNA clones, and evaluation of mass spectrometry peptide hit rates from an A. gambiae shotgun proteomic dataset confirms that the reannotated CDSs offer a high quality protein database for proteomics. We provide a functional proteomics annotation, ReAnoXcel, obtained by analysis of the new CDSs through the AnoXcel pipeline, which allows functional comparisons of the CDS sets within the same bioinformatic platform. CDS data are available for download. Conclusion Comprehensive A. gambiae genome reannotation is achieved through a combination of comparative and ab initio gene prediction algorithms. PMID:16569258

  16. Mapping European Welfare Models: State of the Art of Strategies for Professional Integration and Reintegration of Persons with Chronic Diseases

    PubMed Central

    Scaratti, Chiara; Silvaggi, Fabiola; Ávila, Carolina C.; Muñoz-Murillo, Amalia; Stavroussi, Panayiota; Roka, Olga; Burger, Helena; Fheodoroff, Klemens; Tobiasz-Adamczyk, Beata; Gruber, Sonja; Svestkova, Olga; Halvorsen, Rune; Kadyrbaeva, Asel; Ferraina, Sabrina

    2018-01-01

    Background: Persons with chronic diseases (PwCDs) often experience work-related problems, and innovative actions to improve their participation in the labor market are needed. In the frame of the European (EU) Pathways Project, the aim of the study is to compare existing strategies (policies, systems, and services) for professional (re-)integration of PwCDs and mental health conditions available at both European and national level between different European welfare models: Scandinavian, Continental, Anglo-Saxon, Mediterranean, and “Post-Communist”. Method: The European strategies were identified by an overview of relevant academic and grey literature searched through Medline and internet searches, while national strategies were explored through questionnaires and in-depth interviews with national relevant stakeholders. Results: The mapping of existing strategies revealed that, both at European and national level, PwCDs are often considered as part of the group of “persons with disabilities” and only in this case they can receive employment support. European countries put in place actions to support greater labor market participation, but these differ from country to country. Conclusion: Strategies targeting “persons with disabilities” do not necessarily address all the needs of persons with chronic diseases. Countries should consider the importance of employment for all to achieve smart, sustainable, and inclusive growth. PMID:29673231

  17. CDS - Database Administrator's Guide

    NASA Astrophysics Data System (ADS)

    Day, J. P.

    This guide aims to instruct the CDS database administrator in: o The CDS file system. o The CDS index files. o The procedure for assimilating a new CDS tape into the database. It is assumed that the administrator has read SUN/79.

  18. Predictive Analytics for Identification of Patients at Risk for QT Interval Prolongation - A Systematic Review.

    PubMed

    Tomaselli Muensterman, Elena; Tisdale, James E

    2018-06-08

    Prolongation of the heart rate-corrected QT (QTc) interval increases the risk for torsades de pointes (TdP), a potentially fatal arrhythmia. The likelihood of TdP is higher in patients with risk factors, which include female sex, older age, heart failure with reduced ejection fraction, hypokalemia, hypomagnesemia, concomitant administration of ≥ 2 QTc interval-prolonging medications, among others. Assessment and quantification of risk factors may facilitate prediction of patients at highest risk for developing QTc interval prolongation and TdP. Investigators have utilized the field of predictive analytics, which generates predictions using techniques including data mining, modeling, machine learning, and others, to develop methods of risk quantification and prediction of QTc interval prolongation. Predictive analytics have also been incorporated into clinical decision support (CDS) tools to alert clinicians regarding patients at increased risk of developing QTc interval prolongation. The objectives of this paper are to assess the effectiveness of predictive analytics for identification of patients at risk of drug-induced QTc interval prolongation, and to discuss the efficacy of incorporation of predictive analytics into CDS tools in clinical practice. A systematic review of English language articles (human subjects only) was performed, yielding 57 articles, with an additional 4 articles identified from other sources; a total of 10 articles were included in this review. Risk scores for QTc interval prolongation have been developed in various patient populations including those in cardiac intensive care units (ICUs) and in broader populations of hospitalized or health system patients. One group developed a risk score that includes information regarding genetic polymorphisms; this score significantly predicted TdP. Development of QTc interval prolongation risk prediction models and incorporation of these models into CDS tools reduces the risk of QTc interval prolongation in cardiac ICUs and identifies health-system patients at increased risk for mortality. The impact of these QTc interval prolongation predictive analytics on overall patient safety outcomes, such as TdP and sudden cardiac death relative to the cost of development and implementation, requires further study. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Evaluation of medication alerts in electronic health records for compliance with human factors principles

    PubMed Central

    Phansalkar, Shobha; Zachariah, Marianne; Seidling, Hanna M; Mendes, Chantal; Volk, Lynn; Bates, David W

    2014-01-01

    Introduction Increasing the adoption of electronic health records (EHRs) with integrated clinical decision support (CDS) is a key initiative of the current US healthcare administration. High over-ride rates of CDS alerts strongly limit these potential benefits. As a result, EHR designers aspire to improve alert design to achieve better acceptance rates. In this study, we evaluated drug–drug interaction (DDI) alerts generated in EHRs and compared them for compliance with human factors principles. Methods We utilized a previously validated questionnaire, the I-MeDeSA, to assess compliance with nine human factors principles of DDI alerts generated in 14 EHRs. Two reviewers independently assigned scores evaluating the human factors characteristics of each EHR. Rankings were assigned based on these scores and recommendations for appropriate alert design were derived. Results The 14 EHRs evaluated in this study received scores ranging from 8 to 18.33, with a maximum possible score of 26. Cohen's κ (κ=0.86) reflected excellent agreement among reviewers. The six vendor products tied for second and third place rankings, while the top system and bottom five systems were home-grown products. The most common weaknesses included the absence of characteristics such as alert prioritization, clear and concise alert messages indicating interacting drugs, actions for clinical management, and a statement indicating the consequences of over-riding the alert. Conclusions We provided detailed analyses of the human factors principles which were assessed and described our recommendations for effective alert design. Future studies should assess whether adherence to these recommendations can improve alert acceptance. PMID:24780721

  20. On the Role of High Amounts of Mn Element in CdS Structure

    NASA Astrophysics Data System (ADS)

    Gonullu, Meryem Polat; Kose, Salih

    2017-03-01

    CdS and MnS are technologically important semiconducting materials. In this work, due to the limited ability of these materials separately, a detailed characterization of the new samples formed by the combined use of them has been reported. CdS films, with the incorporation of Mn in a wide range of concentrations, have been produced by a low-cost Ultrasonic Spray Pyrolysis set-up. Spectroscopic Ellipsometry (SE) has been used to determine the thicknesses and optical constants ( n, k) of the samples. It has been determined that samples with high amounts of Mn have lower refractive index values. Absorbance spectra have shown additional band edges along with the one belonging to CdS, for samples with Mn concentrations higher than 50 pct. This has been attributed to a phase separation above this limit. Raman spectroscopy analysis which shows additional Raman peaks belonging to MnS phase also supports these findings. Depending on this phase separation, crystalline structure has been deteriorated. Surface properties of the samples have been investigated by SEM and AFM. Elemental analysis has been performed by EDS. Resistivity measurements performed by a four-probe set-up have shown that samples containing high amount of Mn have lower electrical resistivity values.

  1. Facile synthesis and luminescence characteristics of high-quality CdS: Eu/ZnS core/shell nanocrystals with biocompatibility.

    PubMed

    Zhang, Kexin; Zhang, Rui; Yu, Yaxin; Sun, Shuqing

    2012-04-01

    In this paper, we report a facile method to synthesize high quality CdS: Eu nanocrystals (NCs) and CdS: Eu/ZnS NCs with strong photoluminescence (PL). The influence of various experimental variables including the concentration of Eu3+ ions, the reaction time and the reaction temperature were investigated systematically. In addition, the PL properties of CdS: Eu NCs exhibited pH sensitive. Under the acid condition, pH value of the CdS: Eu NCs solution played an important role in determining PL emission intensity. However, under the alkaline condition, the obtained CdS: Eu NCs exhibited a tunable PL emission wavelength (from 490 nm to 610 nm) when pH value was adjusted from pH 7 to 10. After coating with ZnS shell, the CdS: Eu/ZnS NCs showed enhanced PL intensity compare with one of the CdS: Eu NCs. The CdS: Eu NCs and CdS: Eu/ZnS NCs were characterized by X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM). In addition, the biocompatibility of these NCs was measured by hemolytic test, which indicated that CdS: Eu/ZnS NCs were more biocompatible than CdS: Eu NCs at the same conditions. It can be expected that CdS: Eu/ZnS NCs are promising biolabeling materials.

  2. Status of neurology medical school education: results of 2005 and 2012 clerkship director survey.

    PubMed

    Carter, Jonathan L; Ali, Imran I; Isaacson, Richard S; Safdieh, Joseph E; Finney, Glen R; Sowell, Michael K; Sam, Maria C; Anderson, Heather S; Shin, Robert K; Kraakevik, Jeff A; Coleman, Mary; Drogan, Oksana

    2014-11-04

    To survey all US medical school clerkship directors (CDs) in neurology and to compare results from a similar survey in 2005. A survey was developed by a work group of the American Academy of Neurology Undergraduate Education Subcommittee, and sent to all neurology CDs listed in the American Academy of Neurology database. Comparisons were made to a similar 2005 survey. Survey response rate was 73%. Neurology was required in 93% of responding schools. Duration of clerkships was 4 weeks in 74% and 3 weeks in 11%. Clerkships were taken in the third year in 56%, third or fourth year in 19%, and fourth year in 12%. Clerkship duration in 2012 was slightly shorter than in 2005 (fewer clerkships of ≥4 weeks, p = 0.125), but more clerkships have moved into the third year (fewer neurology clerkships during the fourth year, p = 0.051). Simulation training in lumbar punctures was available at 44% of schools, but only 2% of students attempted lumbar punctures on patients. CDs averaged 20% protected time, but reported that they needed at least 32%. Secretarial full-time equivalent was 0.50 or less in 71% of clerkships. Eighty-five percent of CDs were "very satisfied" or "somewhat satisfied," but more than half experienced "burnout" and 35% had considered relinquishing their role. Trends in neurology undergraduate education since 2005 include shorter clerkships, migration into the third year, and increasing use of technology. CDs are generally satisfied, but report stressors, including inadequate protected time and departmental support. © 2014 American Academy of Neurology.

  3. Status of neurology medical school education

    PubMed Central

    Ali, Imran I.; Isaacson, Richard S.; Safdieh, Joseph E.; Finney, Glen R.; Sowell, Michael K.; Sam, Maria C.; Anderson, Heather S.; Shin, Robert K.; Kraakevik, Jeff A.; Coleman, Mary; Drogan, Oksana

    2014-01-01

    Objective: To survey all US medical school clerkship directors (CDs) in neurology and to compare results from a similar survey in 2005. Methods: A survey was developed by a work group of the American Academy of Neurology Undergraduate Education Subcommittee, and sent to all neurology CDs listed in the American Academy of Neurology database. Comparisons were made to a similar 2005 survey. Results: Survey response rate was 73%. Neurology was required in 93% of responding schools. Duration of clerkships was 4 weeks in 74% and 3 weeks in 11%. Clerkships were taken in the third year in 56%, third or fourth year in 19%, and fourth year in 12%. Clerkship duration in 2012 was slightly shorter than in 2005 (fewer clerkships of ≥4 weeks, p = 0.125), but more clerkships have moved into the third year (fewer neurology clerkships during the fourth year, p = 0.051). Simulation training in lumbar punctures was available at 44% of schools, but only 2% of students attempted lumbar punctures on patients. CDs averaged 20% protected time, but reported that they needed at least 32%. Secretarial full-time equivalent was 0.50 or less in 71% of clerkships. Eighty-five percent of CDs were “very satisfied” or “somewhat satisfied,” but more than half experienced “burnout” and 35% had considered relinquishing their role. Conclusion: Trends in neurology undergraduate education since 2005 include shorter clerkships, migration into the third year, and increasing use of technology. CDs are generally satisfied, but report stressors, including inadequate protected time and departmental support. PMID:25305155

  4. Nitrogen and sulfur co-doped carbon dots with strong blue luminescence

    NASA Astrophysics Data System (ADS)

    Ding, Hui; Wei, Ji-Shi; Xiong, Huan-Ming

    2014-10-01

    Sulfur-doped carbon dots (S-CDs) with a quantum yield (QY) of 5.5% and nitrogen, sulfur co-doped carbon dots (N,S-CDs) with a QY of 54.4% were synthesized, respectively, via the same hydrothermal route using α-lipoic acid as the carbon source. The obtained S-CDs and N,S-CDs had similar sizes but different optical features. The QY of N,S-CDs was gradually enhanced when extending the reaction time to increase the nitrogen content. After careful characterization of these CDs, the doped nitrogen element was believed to be in the form of C&z.dbd;N and C-N bonds which enhanced the fluorescence efficiency significantly. Meanwhile, the co-doped sulfur element was found to be synergistic for nitrogen doping in N,S-CDs. The optimal N,S-CDs were successfully employed as good multicolor cell imaging probes due to their fine dispersion in water, excitation-dependent emission, excellent fluorescence stability and low toxicity. Besides, such N,S-CDs showed a wide detection range and excellent accuracy as fluorescent sensors for Fe3+ ions.Sulfur-doped carbon dots (S-CDs) with a quantum yield (QY) of 5.5% and nitrogen, sulfur co-doped carbon dots (N,S-CDs) with a QY of 54.4% were synthesized, respectively, via the same hydrothermal route using α-lipoic acid as the carbon source. The obtained S-CDs and N,S-CDs had similar sizes but different optical features. The QY of N,S-CDs was gradually enhanced when extending the reaction time to increase the nitrogen content. After careful characterization of these CDs, the doped nitrogen element was believed to be in the form of C&z.dbd;N and C-N bonds which enhanced the fluorescence efficiency significantly. Meanwhile, the co-doped sulfur element was found to be synergistic for nitrogen doping in N,S-CDs. The optimal N,S-CDs were successfully employed as good multicolor cell imaging probes due to their fine dispersion in water, excitation-dependent emission, excellent fluorescence stability and low toxicity. Besides, such N,S-CDs showed a wide detection range and excellent accuracy as fluorescent sensors for Fe3+ ions. Electronic supplementary information (ESI) available: Experimental details and comparable characterization of three kinds of CDs. See DOI: 10.1039/c4nr04267k

  5. Phosphorene Co-catalyst Advancing Highly Efficient Visible-Light Photocatalytic Hydrogen Production.

    PubMed

    Ran, Jingrun; Zhu, Bicheng; Qiao, Shi-Zhang

    2017-08-21

    Transitional metals are widely used as co-catalysts boosting photocatalytic H 2 production. However, metal-based co-catalysts suffer from high cost, limited abundance and detrimental environment impact. To date, metal-free co-catalyst is rarely reported. Here we for the first time utilized density functional calculations to guide the application of phosphorene as a high-efficiency metal-free co-catalyst for CdS, Zn 0.8 Cd 0.2 S or ZnS. Particularly, phosphorene modified CdS shows a high apparent quantum yield of 34.7 % at 420 nm. This outstanding activity arises from the strong electronic coupling between phosphorene and CdS, as well as the favorable band structure, high charge mobility and massive active sites of phosphorene, supported by computations and advanced characterizations, for example, synchrotron-based X-ray absorption near edge spectroscopy. This work brings new opportunities to prepare highly-active, cheap and green photocatalysts. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Evaluation of children with lymphatic malformations of the head and neck using the Cologne Disease Score.

    PubMed

    Wiegand, Susanne; Eivazi, Behfar; Zimmermann, Annette P; Sesterhenn, Andreas M; Werner, Jochen A

    2009-07-01

    To assess the disease-related impairments of children with lymphatic malformations of the head and neck and their changes after therapy using the Cologne Disease Score (CDS). 29 children with lymphatic malformations of the head and neck were evaluated regarding their symptoms before and after therapy using the CDS. The Wilcoxon test for dependent groups was used to compare the CDS at initial visit before treatment and last visit after treatment. The CDS of patients belonging to the moderate (initial CDS: more than eight points) and advanced disease group (initial CDS: five, six or seven points) significantly increased after therapy while the patients in the severe disease group (initial CDS: lower than four points) showed no significant improvement of CDS. Patients with stage IV and especially stage V lymphatic malformations according to de Serres showed considerably lower pre- and posttherapeutic CDS levels than those of stage I and II. The visual impairment is not mapped by the CDS, therefore item vision should be added to the CDS to make an evaluation of all lymphatic malformations of the head and neck possible. The present series could show that especially patients with a moderate or advanced disease according to the CDS may profit from therapeutic interventions.

  7. One pot synthesis of highly luminescent polyethylene glycol anchored carbon dots functionalized with a nuclear localization signal peptide for cell nucleus imaging.

    PubMed

    Yang, Lei; Jiang, Weihua; Qiu, Lipeng; Jiang, Xuewei; Zuo, Daiying; Wang, Dongkai; Yang, Li

    2015-04-14

    Strong blue fluorescent polyethylene glycol (PEG) anchored carbon nitride dots (CDs@PEG) with a high quantum yield (QY) of 75.8% have been synthesized by a one step hydrothermal treatment. CDs with a diameter of ca. 6 nm are well dispersed in water and present a graphite-like structure. Photoluminescence (PL) studies reveal that CDs display excitation-dependent behavior and are stable under various test conditions. Based on the as-prepared CDs, we designed novel cell nucleus targeting imaging carbon dots functionalized with a nuclear localization signal (NLS) peptide. The favourable biocompatibilities of CDs and NLS modified CDs (NLS-CDs) are confirmed by in vitro cytotoxicity assays. Importantly, intracellular localization experiments in MCF7 and A549 cells demonstrate that NLS-CDs could be internalized in the nucleus and show blue light, which indicates that CDs may serve as cell nucleus imaging probes.

  8. Fabrication of CDs/CdS-TiO2 ternary nano-composites for photocatalytic degradation of benzene and toluene under visible light irradiation

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Hua, Jianhao; Yang, Yaling

    2018-06-01

    An efficient cadmium sulfide quantum-dots (CdS QDs) and carbon dots (CDs) modified TiO2 photocatalyst (CdS/CDs-TiO2) was successfully fabricated. The as-prepared ternary nano-composites simultaneously improved the photo-corrosion of CdS and amplified its photocatalytic activity. The introduction of CdS QDs and CDs could enhance more absorbance of light, prevent the undesirable electron/hole recombination, and promote charge separation, which was important for the continuous formation of rad OH and rad O2- radicals. When the optimal mass ratio of CdS QDs to CDs was 3:1, above 90% degradation efficiencies were achieved for benzene within 1 h and toluene in 2 h, while that of pure TiO2 (P25), CdS QDs-TiO2, CDs-TiO2 nano-composites was around 15%. Owing to the symmetric structure and conjugation of methyl with benzene ring, the degradation of toluene was more difficult than benzene to carry on. The new fabricated nano-composites showed good prospective application of cleaning up refractory pollutants and the resource utilization.

  9. Green preparation of carbon dots with papaya as carbon source for effective fluorescent sensing of Iron (III) and Escherichia coli.

    PubMed

    Wang, Ning; Wang, Yiting; Guo, Tingting; Yang, Ting; Chen, Mingli; Wang, Jianhua

    2016-11-15

    A simple one-step hydrothermal green approach was reported for the preparation of carbon dots (CDs) without any further decoration or modification with papaya powder as natural carbon source. In this economical and eco-friendly system, deionized water or 90% ethanol was used as solvent to produce water-soluble or ethanol-soluble CDs, respectively, termed as W-CDs and E-CDs. The quantum yield (QY) for W-CDs was 18.98%, while that for E-CDs was 18.39%. The potentials of the prepared carbon dots toward diverse applications were thoroughly investigated. W-CDs and E-CDs provide promising probes for fluorescence detection of Fe(3+), offering limits of detection of 0.48μmolL(-1) and 0.29μmolL(-1), respectively. W-CDs was further demonstrated to be a promising probe for fluorescence sensing of Escherichia coli O157: H7, along with a limit of detection of 9.5×10(4)cfumL(-1). Meanwhile, both W-CDs and E-CDs exhibit favorable biocompatibility, and demonstrated to be efficient for Hela cell imaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Highly Efficient Photocatalytic Hydrogen Production of Flower-like Cadmium Sulfide Decorated by Histidine

    PubMed Central

    Wang, Qizhao; Lian, Juhong; Li, Jiajia; Wang, Rongfang; Huang, Haohao; Su, Bitao; Lei, Ziqiang

    2015-01-01

    Morphology-controlled synthesis of CdS can significantly enhance the efficiency of its photocatalytic hydrogen production. In this study, a novel three-dimensional (3D) flower-like CdS is synthesized via a facile template-free hydrothermal process using Cd(NO3)2•4H2O and thiourea as precursors and L-Histidine as a chelating agent. The morphology, crystal phase, and photoelectrochemical performance of the flower-like CdS and pure CdS nanocrystals are carefully investigated via various characterizations. Superior photocatalytic activity relative to that of pure CdS is observed on the flower-like CdS photocatalyst under visible light irradiation, which is nearly 13 times of pure CdS. On the basis of the results from SEM studies and our analysis, a growth mechanism of flower-like CdS is proposed by capturing the shape evolution. The imidazole ring of L-Histidine captures the Cd ions from the solution, and prevents the growth of the CdS nanoparticles. Furthermore, the photocatalytic contrast experiments illustrate that the as-synthesized flower-like CdS with L-Histidine is more stable than CdS without L-Histidine in the hydrogen generation. PMID:26337119

  11. Highly Efficient Photocatalytic Hydrogen Production of Flower-like Cadmium Sulfide Decorated by Histidine

    NASA Astrophysics Data System (ADS)

    Wang, Qizhao; Lian, Juhong; Li, Jiajia; Wang, Rongfang; Huang, Haohao; Su, Bitao; Lei, Ziqiang

    2015-09-01

    Morphology-controlled synthesis of CdS can significantly enhance the efficiency of its photocatalytic hydrogen production. In this study, a novel three-dimensional (3D) flower-like CdS is synthesized via a facile template-free hydrothermal process using Cd(NO3)2•4H2O and thiourea as precursors and L-Histidine as a chelating agent. The morphology, crystal phase, and photoelectrochemical performance of the flower-like CdS and pure CdS nanocrystals are carefully investigated via various characterizations. Superior photocatalytic activity relative to that of pure CdS is observed on the flower-like CdS photocatalyst under visible light irradiation, which is nearly 13 times of pure CdS. On the basis of the results from SEM studies and our analysis, a growth mechanism of flower-like CdS is proposed by capturing the shape evolution. The imidazole ring of L-Histidine captures the Cd ions from the solution, and prevents the growth of the CdS nanoparticles. Furthermore, the photocatalytic contrast experiments illustrate that the as-synthesized flower-like CdS with L-Histidine is more stable than CdS without L-Histidine in the hydrogen generation.

  12. Highly Efficient Photocatalytic Hydrogen Production of Flower-like Cadmium Sulfide Decorated by Histidine.

    PubMed

    Wang, Qizhao; Lian, Juhong; Li, Jiajia; Wang, Rongfang; Huang, Haohao; Su, Bitao; Lei, Ziqiang

    2015-09-04

    Morphology-controlled synthesis of CdS can significantly enhance the efficiency of its photocatalytic hydrogen production. In this study, a novel three-dimensional (3D) flower-like CdS is synthesized via a facile template-free hydrothermal process using Cd(NO3)2•4H2O and thiourea as precursors and L-Histidine as a chelating agent. The morphology, crystal phase, and photoelectrochemical performance of the flower-like CdS and pure CdS nanocrystals are carefully investigated via various characterizations. Superior photocatalytic activity relative to that of pure CdS is observed on the flower-like CdS photocatalyst under visible light irradiation, which is nearly 13 times of pure CdS. On the basis of the results from SEM studies and our analysis, a growth mechanism of flower-like CdS is proposed by capturing the shape evolution. The imidazole ring of L-Histidine captures the Cd ions from the solution, and prevents the growth of the CdS nanoparticles. Furthermore, the photocatalytic contrast experiments illustrate that the as-synthesized flower-like CdS with L-Histidine is more stable than CdS without L-Histidine in the hydrogen generation.

  13. Efficient synthesis of highly fluorescent nitrogen-doped carbon dots for cell imaging using unripe fruit extract of Prunus mume

    NASA Astrophysics Data System (ADS)

    Atchudan, Raji; Edison, Thomas Nesakumar Jebakumar Immanuel; Sethuraman, Mathur Gopalakrishnan; Lee, Yong Rok

    2016-10-01

    Highly fluorescent nitrogen-doped carbon dots (N-CDs) were synthesized using the extract of unripe Prunus mume (P. mume) fruit by a simple one step hydrothermal-carbonization method. The N-CDs were synthesized at different pH ranges, 2.3, 5, 7, and 9. The pH of the P. mume extract was adjusted using an aqueous ammonia solution (25%). The optical properties of N-CDs were examined by UV-vis and fluorescence spectroscopy. The N-CDs synthesized at pH 9 emitted high fluorescence intensity compared to other obtained N-CDs. The N-CDs synthesized at pH 9 was further characterized by high resolution transmission electron microscopy (HR-TEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and Fourier transform-infra red (FT-IR) spectroscopy. HR-TEM showed that the average size of the synthesized N-CDs was approximately 9 nm and the interlayer distance was 0.21 nm, which was validated by XRD. The graphitic nature of the synthesized N-CDs were confirmed by Raman spectroscopy. XPS and FT-IR spectroscopy confirmed the doping of the nitrogen moiety over the synthesized CDs. The synthesized nitrogen doped CDs (N-CDs) were low toxicity and were used as a staining probe for fluorescence cell imaging.

  14. The application of consequence models in risk assessment: A regulator`s view

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nussey, C.; Carter, D.A.; Cassidy, K.

    1995-12-31

    Quantified risk assessment (QRA) is a technique for aiding decision making. The UK Health and Safety Executive (HSE) uses QRA in the Major Hazards (MH) area to formulate advice to Local Planning Authorities (LPAs) on the siting of MH installations and the development of land in the vicinity of existing MH installations. The region around UK MH sites within which LPAs are required to consult HSE on land-use planning matters (i.e. the Consultation Distance (CD)) is increasingly being redefined by adopting a risk based approach. The authors are now in the process of conducting or updated site specific QRAs tomore » redefine CDs. This process enables them to identify risk reduction measures and discuss them with companies, taking into consideration the ALARP--as low as is reasonably practicable--philosophy. The paper outlines the basis of the QRAs and the role of consequence assessment models and procedures in this process, and illustrates by examples the setting of CDs and the application of the ALARP philosophy.« less

  15. A bifacial quantum dot-sensitized solar cell with all-cadmium sulfide photoanode

    NASA Astrophysics Data System (ADS)

    Ma, Chunqing; Tang, Qunwei; Liu, Danyang; Zhao, Zhiyuan; He, Benlin; Chen, Haiyan; Yu, Liangmin

    2015-02-01

    Pursuit of a high power conversion efficiency and reduction of electricity-generation cost has been a persistent objective for quantum dot-sensitized solar cells (QDSSCs). We present here the fabrication of a QDSSC comprising a nanoflower-structured CdS anode, a liquid electrolyte having S2-/Sn2- redox couples, and a transparent CoSe counter electrode. Nanoflower-structured CdS anodes are prepared by a successive ionic layer adsorption and reaction (SILAR) method and subsequently hydrothermal strategy free of any surfactant or template. The CdS nanoparticles synthesized by a SILAR method act as "seed crystal" for growth of CdS nanoflowers. The average electron lifetime is markedly elevated in nanoflower-structured CdS anode in comparison with CdS nanoparticle or nanoporous CdS microsphere anode. Herein, we study the effect of synthesis method on CdS morphology and solar cell's photovoltaic performance, showing a power conversion efficiency of 1.67% and 1.17% for nanoflower-structured CdS QDSSC under front and rear irradiations, respectively.

  16. Learning Healthcare System for the Prescription of Genetic Testing in the Gynecological Cancer Risk.

    PubMed

    Suárez-Mejías, Cristina; Martínez-García, Alicia; Martínez-Maestre, María Ángeles; Silvan-Alfaro, José Manuel; Moreno Conde, Jesús; Parra-Calderón, Carlos Luis

    2017-01-01

    Clinical evidence demonstrates that BRCA 1 and BRCA2 mutations can develop a gynecological cancer but genetic testing has a high cost to the healthcare system. Besides, several studies in the literature indicate that performing these genetic tests to the population is not cost-efficient. Currently, our physicians do not have a system to provide them the support for prescribing genetic tests. A Decision Support System for prescribing these genetic tests in BRCA1 and BRCA2 and preventing gynecological cancer risks has been designed, developed and deployed in the Virgen del Rocío University Hospital (VRUH). The technological architecture integrates a set of open source tools like Mirth Connect, OpenClinica, OpenCDS, and tranSMART in addition to several interoperability standards. The system allows general practitioners and gynecologists to classify patients as low risk (they do not require a specific treatment) or high risk (they should be attended by the Genetic Council). On the other hand, by means of this system we are also able to standardize criteria among professionals to prescribe these genetic tests. Finally, this system will also contribute to improve the assistance for this kind of patients.

  17. Closed depressions in the European loess belt - Natural or anthropogenic origin?

    NASA Astrophysics Data System (ADS)

    Kołodyńska-Gawrysiak, Renata; Poesen, Jean

    2017-07-01

    Closed depressions (CDs) are typical geomorphological features of the loess belt in Europe. CDs have been reported in several regions of the European loess belt, where they are described as hollows, mardeles, wymoki, crovuri, bludtsa and zapadiny. The natural and anthropogenic origins of CDs are debated in literature. Moreover, no comprehensive review of the geomorphic properties or the evolution of these depressions exists. Therefore this paper reviews the characteristics of CDs in the European loess belt and attempts to better understand their genesis based on detailed case studies. The main morphometric features as well as sediment deposits within CDs in several sub-regions of Europe were analysed and compared. Morphometric properties of CDs from the West European and East European loess belt were investigated through a comparison of CDs from two representative regions, i.e. East Poland and Central Belgium. In both study areas, CDs under cropland are similar. However, a comparison of morphological features of CDs under forest, revealed clear differences, suggesting a different origin of CDs from both regions. Infilled sediments in CDs show various litho-genetical features in different regions of the European loess belt. The morphometric features, ages and stratigraphy of infillings clearly indicate that both anthropogenic and natural processes have shaped these landforms within the loess belt of Europe. CDs observed in Eastern Europe may have a very different origin than those documented in Western Europe. Detailed analysis of CDs in Poland and in neighbouring regions of East Europe, suggest that CDs are natural landforms: thermokarst, deflation and dissolution of loess are reported as probable genetic processes. In contrast, several studies in Western Europe indicate a dominant anthropogenic origin (i.e. digging of calcareous loess or marls, bomb and mining craters, collapse of underground limestone quarries), although CDs formed by natural processes (i.e. piping, dissolution of limestone and salt lenses below the loess cover) are reported as well. CDs act as important archives, allowing one to reconstruct both natural and anthropogenic processes operating in the past. As CDs store most sediments eroded within their catchment they provide ideal sediment traps to assess long-term erosion rates in these environments which have hitherto been under-researched. More research is needed to unravel the genesis and evolution of these depressions to better understand the importance of the Late Glacial and Holocene stages for the morphogenesis of the loess belt in Europe.

  18. Mapping European Welfare Models: State of the Art of Strategies for Professional Integration and Reintegration of Persons with Chronic Diseases.

    PubMed

    Scaratti, Chiara; Leonardi, Matilde; Silvaggi, Fabiola; Ávila, Carolina C; Muñoz-Murillo, Amalia; Stavroussi, Panayiota; Roka, Olga; Burger, Helena; Fheodoroff, Klemens; Tobiasz-Adamczyk, Beata; Sabariego, Carla; Esteban, Eva; Gruber, Sonja; Svestkova, Olga; Halvorsen, Rune; Kadyrbaeva, Asel; Ferraina, Sabrina

    2018-04-17

    Background: Persons with chronic diseases (PwCDs) often experience work-related problems, and innovative actions to improve their participation in the labor market are needed. In the frame of the European (EU) Pathways Project, the aim of the study is to compare existing strategies (policies, systems, and services) for professional (re-)integration of PwCDs and mental health conditions available at both European and national level between different European welfare models: Scandinavian, Continental, Anglo-Saxon, Mediterranean, and “Post-Communist”. Method : The European strategies were identified by an overview of relevant academic and grey literature searched through Medline and internet searches, while national strategies were explored through questionnaires and in-depth interviews with national relevant stakeholders. Results : The mapping of existing strategies revealed that, both at European and national level, PwCDs are often considered as part of the group of “persons with disabilities” and only in this case they can receive employment support. European countries put in place actions to support greater labor market participation, but these differ from country to country. Conclusion : Strategies targeting “persons with disabilities” do not necessarily address all the needs of persons with chronic diseases. Countries should consider the importance of employment for all to achieve smart, sustainable, and inclusive growth.

  19. Sandwiched ZnO@Au@CdS nanorod arrays with enhanced visible-light-driven photocatalytical performance

    NASA Astrophysics Data System (ADS)

    Ren, Shoutian; Wang, Yingying; Fan, Guanghua; Gao, Renxi; Liu, Wenjun

    2017-11-01

    The development of high-performance photocatalysts is central to efforts focused on taking advantage of solar energy to overcome environmental and energy crises. Integrating different functional materials artfully into nanostructures can deliver more efficient photocatalytic activity. Here, sandwiched ZnO@Au@CdS nanorod films were synthesized via successive ZnO nanorod electrodeposition, Au sputtering and CdS electrodeposition. The as-synthesized composites were characterized by UV-vis spectrophotometer, x-ray diffractometer, scanning and transmission electron microscopy. Their photocatalytic activity was assessed by degrading Rhodamine B solution under visible light irradiation. ZnO@Au@CdS exhibited better photocatalytic performance than ZnO@CdS throughout the visible light region, and the corresponding enhancement factor of Au nanoparticles was measured as a function of CdS loading amount, and it could reach 190% with CdS deposition for 1 min. The normalized rate constant could reach 0.387 h-1 for ZnO@Au@CdS-1min, which was equivalent to or better than results in reference photocatalysts. The enhancement mechanism of Au nanoparticles was estimated by comparing the monochromatic photocatalytic action spectra with the absorption spectrum of ZnO@Au@CdS, and it was mainly determined by incident photon energy. With selective excitation of Au nanoparticles by incident photons, the excited hot electrons in Au NPs are transferred to the conduction band of ZnO to boost photocatalytic reaction. With selective excitation of CdS, the enhanced interband absorption of CdS and relay station effect of Au nanoparticles should be responsible for the enhanced photocatalytic performance. Our work not only opens the door to the design of efficient supported photocatalysts, but also helps to understand the enhancement mechanism of LSPR effect on the photoelectric conversion of semiconductors.

  20. Green synthesis of multifunctional carbon dots from coriander leaves and their potential application as antioxidants, sensors and bioimaging agents.

    PubMed

    Sachdev, Abhay; Gopinath, P

    2015-06-21

    In the present study, a facile one-step hydrothermal treatment of coriander leaves for preparing carbon dots (CDs) has been reported. Optical and structural properties of the CDs have been extensively studied by UV-visible and fluorescence spectroscopic, microscopic (transmission electron microscopy, scanning electron microscopy) and X-ray diffraction techniques. Surface functionality and composition of the CDs have been illustrated by elemental analysis and Fourier transform infrared spectroscopy (FTIR). Quenching of the fluorescence of the CDs in the presence of metal ions is of prime significance, hence CDs have been used as a fluorescence probe for sensitive and selective detection of Fe(3+) ions. Eventually, biocompatibility and bioimaging aspects of CDs have been evaluated on lung normal (L-132) and cancer (A549) cell lines. Qualitative analysis of cellular uptake of CDs has been pursued through fluorescence microscopy, while quantitative analysis using a flow cytometer provided an insight into the concentration and cell-type dependent uptake of CDs. The article further investigates the antioxidant activity of CDs. Therefore, we have validated the practicality of CDs obtained from a herbal carbon source for versatile applications.

  1. Preparation of highly luminescent and biocompatible carbon dots using a new extraction method

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Liu, Ying-Bo; Sun, Shu-Qing

    2013-10-01

    C dots (CDs) are among the most promising emerging fluorescent labels for biological imaging and sensing. A facile new synthesis method was developed using common organic solvents for fabricating CDs from candle soot. The common organic solvents were used as extractants and the obtained CDs have a narrow size distribution with average diameters of about 3.4 nm for ethylene glycol, 3.5 nm for ethanol, and 3.4 nm for n-butanol. This approach is simpler, easier, and more effective than other methods currently used for CD fabrication. The obtained CDs had a high quantum yield (38 %), tunable emission and are water-soluble. The mechanism for the luminescence of the CDs was investigated and the results indicate that the ability of the solvent to disperse the CDs plays a very important role in the photoluminescence of these CDs. The type of organic solvent and the surface groups on the CDs also influenced the optical properties of the CDs. Different emissive traps are shown to play the major role in the luminescence of the carbon materials. An in vitro hemolysis assay was performed and showed that the CDs are biocompatible.

  2. Preoperative planning of calcium deposit removal in calcifying tendinitis of the rotator cuff - possible contribution of computed tomography, ultrasound and conventional X-Ray.

    PubMed

    Izadpanah, Kaywan; Jaeger, Martin; Maier, Dirk; Südkamp, Norbert P; Ogon, Peter

    2014-11-20

    The purpose of the present study was to investigate the accuracy of Ultrasound (US), conventional X-Ray (CX) and Computed Tomography (CT) to estimate the total count, localization, morphology and consistency of Calcium deposits (CDs) in the rotator cuff. US, CX and CT imaging was performed pre-operatively in 151 patients who underwent arthroscopic removal of CDs in the rotator cuff. In all procedures: (1) total CD counts were determined, (2) the CDs appearance in each image modality was correlated to the intraoperative consistency and (3) CDs were localized in their relation to the acromion using US, CX and CT. Using US158 CDs, using CT 188 CDs and using CX 164 CDs were identified. Reliable localization of the CDs was possible with all used diagnostic modalities. CT revealed 49% of the CDs to be septated, out of which 85% were uni- and 15% multiseptated. CX was not suitable for prediction of CDs consistency. US reliably predicted viscous-solid CDs consistency only when presenting with full sound extinction (PPV 84.6%) . CT had high positive and negative predictive values for detection of liquid-soft (PPV 92.9%) and viscous-solid (PPV 87.8%) CDs. US and CX are sufficient for preoperative planning of CD removal with regards to localization and prediction of consistency if the deposits present with full sound extinction. This is the case in the majority of the patients. However, in patients with missing sound extinction CT can be recommended if CDs consistency of the deposits should be determined. Satellite deposits or septations are regularly present, which is of importance if complete CD removal is aspired.

  3. Highly fluorescent Zn-doped carbon dots as Fenton reaction-based bio-sensors: an integrative experimental-theoretical consideration.

    PubMed

    Xu, Quan; Liu, Yao; Su, Rigu; Cai, Lulu; Li, Bofan; Zhang, Yingyuan; Zhang, Linzhou; Wang, Yajun; Wang, Yan; Li, Neng; Gong, Xiao; Gu, Zhipeng; Chen, Yusheng; Tan, Yanglan; Dong, Chenbo; Sreeprasad, Theruvakkattil Sreenivasan

    2016-10-20

    Heteroatom doped carbon dots (CDs), with high photoluminescence quantum yield (PLQY), are of keen interest in various applications such as chemical sensors, bio-imaging, electronics, and photovoltaics. Zinc, an important element assisting the electron-transfer process and an essential trace element for cells, is a promising metal dopant for CDs, which could potentially lead to multifunctional CDs. In this contribution, we report a single-step, high efficiency, hydrothermal method to synthesize Zn-doped carbon dots (Zn-CDs) with a superior PLQY. The PLQY and luminescence characteristic of Zn-CDs can be tuned by controlling the precursor ratio, and the surface oxidation in the CDs. Though a few studies have reported metal doped CDs with good PLQY, the as prepared Zn-Cds in the present method exhibited a PLQY up to 32.3%. To the best of our knowledge, there is no report regarding the facile preparation of single metal-doped CDs with a QY more than 30%. Another unique attribute of the Zn-CDs is the high monodispersity and the resultant highly robust excitation-independent luminescence that is stable over a broad range of pH values. Spectroscopic investigations indicated that the superior PLQY and luminescence of Zn-CDs are due to the heteroatom directed, oxidized carbon-based surface passivation. Furthermore, we developed a novel and sensitive biosensor for the detection of hydrogen peroxide and glucose leveraging the robust fluorescence properties of Zn-CDs. Under optimal conditions, Zn-CDs demonstrated high sensitivity and response to hydrogen peroxide and glucose over a wide range of concentrations, with a linear range of 10-80 μM and 5-100 μM, respectively, indicating their great potential as a fluorescent probe for chemical sensing.

  4. Influence of wide band gap oxide substrates on the photoelectrochemical properties and structural disorder of CdS nanoparticles grown by the successive ionic layer adsorption and reaction (SILAR) method

    PubMed Central

    Malashchonak, Mikalai V; Korolik, Olga V; Streltsov, Еugene А; Kulak, Anatoly I

    2015-01-01

    Summary The photoelectrochemical properties of nanoheterostructures based on the wide band gap oxide substrates (ZnO, TiO2, In2O3) and CdS nanoparticles deposited by the successive ionic layer adsorption and reaction (SILAR) method have been studied as a function of the CdS deposition cycle number (N). The incident photon-to-current conversion efficiency (IPCE) passes through a maximum with the increase of N, which is ascribed to the competition between the increase in optical absorption and photocarrier recombination. The maximal IPCE values for the In2O3/CdS and ZnO/CdS heterostructures are attained at N ≈ 20, whereas for TiO2/CdS, the appropriate N value is an order of magnitude higher. The photocurrent and Raman spectroscopy studies of CdS nanoparticles revealed the occurrence of the quantum confinement effect, demonstrating the most rapid weakening with the increase of N in ZnO/CdS heterostructures. The structural disorder of CdS nanoparticles was characterized by the Urbach energy (E U), spectral width of the CdS longitudinal optical (LO) phonon band and the relative intensity of the surface optical (SO) phonon band in the Raman spectra. Maximal values of E U (100–120 meV) correspond to СdS nanoparticles on a In2O3 surface, correlating with the fact that the CdS LO band spectral width and intensity ratio for the CdS SO and LO bands are maximal for In2O3/CdS films. A notable variation in the degree of disorder of CdS nanoparticles is observed only in the initial stages of CdS growth (several tens of deposition cycles), indicating the preservation of the nanocrystalline state of CdS over a wide range of SILAR cycles. PMID:26734517

  5. Influence of wide band gap oxide substrates on the photoelectrochemical properties and structural disorder of CdS nanoparticles grown by the successive ionic layer adsorption and reaction (SILAR) method.

    PubMed

    Malashchonak, Mikalai V; Mazanik, Alexander V; Korolik, Olga V; Streltsov, Еugene А; Kulak, Anatoly I

    2015-01-01

    The photoelectrochemical properties of nanoheterostructures based on the wide band gap oxide substrates (ZnO, TiO2, In2O3) and CdS nanoparticles deposited by the successive ionic layer adsorption and reaction (SILAR) method have been studied as a function of the CdS deposition cycle number (N). The incident photon-to-current conversion efficiency (IPCE) passes through a maximum with the increase of N, which is ascribed to the competition between the increase in optical absorption and photocarrier recombination. The maximal IPCE values for the In2O3/CdS and ZnO/CdS heterostructures are attained at N ≈ 20, whereas for TiO2/CdS, the appropriate N value is an order of magnitude higher. The photocurrent and Raman spectroscopy studies of CdS nanoparticles revealed the occurrence of the quantum confinement effect, demonstrating the most rapid weakening with the increase of N in ZnO/CdS heterostructures. The structural disorder of CdS nanoparticles was characterized by the Urbach energy (E U), spectral width of the CdS longitudinal optical (LO) phonon band and the relative intensity of the surface optical (SO) phonon band in the Raman spectra. Maximal values of E U (100-120 meV) correspond to СdS nanoparticles on a In2O3 surface, correlating with the fact that the CdS LO band spectral width and intensity ratio for the CdS SO and LO bands are maximal for In2O3/CdS films. A notable variation in the degree of disorder of CdS nanoparticles is observed only in the initial stages of CdS growth (several tens of deposition cycles), indicating the preservation of the nanocrystalline state of CdS over a wide range of SILAR cycles.

  6. TiO2 activity enhancement through synergistic effect of photons localization of photonic crystals and the sensitization of CdS quantum dots

    NASA Astrophysics Data System (ADS)

    Li, Ping; Wang, Yuan; Wang, Ai-Jun; Chen, Sheng-Li

    2017-02-01

    In this work, the enhancement of TiO2 photocatalytic activity was studied through synergistic effect of the photons localization of photonic crystals and the sensitization of CdS quantum dots (CdS QDs). CdS QDs sensitized TiO2 membrane (denoted as CdS QDs/TiO2) was synthesized through doping the TiO2 membrane with CdS QDs by chemical bath deposition method (CBD). After TiO2 was sensitized with CdS QDs, the edge of light absorption of TiO2 was red-shifted to 470 nm and the light absorption in the range of 400 600 nm was higher than that of plain TiO2 membrane. Another type of composite membrane, CdS QDs/TiO2/SiO2 opal composite membrane was prepared by coupling SiO2 opal (a kind of photonic crystal) layer onto the CdS QDs/TiO2 membrane, and the photonic band gap of the SiO2 opal photonic crystal layer was deliberately planned at the electronic band gap of the CdS QDs. The photodegradation of gaseous CH3CHO (acetaldehyde) was used as probe reaction to test the photocatalytic activity of the as-prepared membranes, and the results showed that the CdS QDs sensitization can significantly improve the photocatalytic activity of TiO2 membrane under visible light irradiation, with the acetaldehyde degradation rate constant (k) on CdS QDs/TiO2 membranes being 1.59 times of that on plain TiO2 membranes. The acetaldehyde degradation rate constant on CdS QDs/TiO2/SiO2 opal composite membrane reached 4 times of that on plain TiO2 membrane. The photocatalytic activity of TiO2 membrane can be improved through synergistic effect of the photons localization of photonic crystals and the sensitization of CdS QDs.

  7. Assessment of Holocene soil erosion rates on the loess plateau in East Poland using sedimentary archives from closed depressions

    NASA Astrophysics Data System (ADS)

    Kołodyńska-Gawrysiak, Renata; Poesen, Jean; Gawrysiak, Leszek

    2016-04-01

    Closed depressions (CDs) are typical geomorphological features of the European loess belt. They are closed sedimentation basins that enable the estimation of long-term soil erosion rates for different land use environments. This study was conducted in eastern Poland (Nałęczów Plateau). In this region CDs are rather small landforms and the area of 70% of all CDs does not exceed 1500 m2. The study objective was to assess Holocene soil erosion rates in the loess plateau based on a quantitative analysis of colluvial sediments deposited in CDs. Two representative CDs were selected for this study: one CD is located in an old (long-term) forest and the other is situated in a long-term agricultural land. The maximum depth of the CD in the forest, the mean slope gradient and area of the corresponding catchment are 4.9 m, 3.410 and 7568 m² respectively. For the CD in agricultural land these values are 3.2 m, 2.760 and 5156 m² respectively. In both CDs several dozen of drillings and two trenches (2 m long, 1m wide, 2 m deep) were made in the deepest point of the CDs. Mean long-term soil erosion rates were calculated based on the stratigraphy of the soil-sediment sequence infilling the CDs. C-14 and OSL datings of soils and colluvial sediments within the CDs were obtained. For the long-term agricultural used catchment of the CD it was calculated that since 6.31 ± 0.35 ka BP the mean annual soil loss due to water and tillage erosion is 0.63-0.7 t/ha/year or 279.3 mm. In the prehistoric period since 6.31 ± 0.35 ka BP until 1026-1162 AD the mean annual soil erosion rate amounted to 0,10-0.11 t/ha/year or 41.5 mm. During the last ca. 1000 years mean soil erosion rates increased to 3.99-4.63 t/ha/year or 249.2 mm. Results of long-term soil erosion rates (calculated using colluvial sediment sequences in CDs) from agricultural catchments in the loess regions of eastern Poland (this study) and Central Belgium (Gillijns et al. 2005) are quite similar. For the forested catchment of the CD the mean annual soil erosion rate since at least ca. 1000 years is 0.073-0.086 t/ha/year or 41.9 mm. In this catchment soil erosion and correlative colluviation deposits occurred mainly in prehistoric times. CDs play an important role for archiving sediments which allow to reconstruct both natural and anthropogenic processes in the past. The study of these sediment archives allows a better understanding of human-environment interactions and its impact on long-term soil erosion rates. Acknowledgements: The research project was financially supported by the National Centre of Science - project PB-B-12-287-00-13: The origin and evolution of closed depressions in the loess area of the Lublin Upland and their importance for the reconstruction of postglacial morphogenesis of the loess covers. References: Gillijns K., Poesen J., Deckers J., 2005: On the characteristics and origin of closed depression in loess-derived soils in Europe- a case study from central Belgium. Catena 60, 43-58.

  8. Structural and optoelectronic studies on Ag-CdS quantum dots

    NASA Astrophysics Data System (ADS)

    Ibrahim Mohammed S., M.; Gubari, Ghamdan M. M.; Huse, Nanasaheb P.; Dive, Avinash S.; Sharma, Ramphal

    2018-05-01

    In the present study, we have successfully deposited CdS quantum dot thin films and Ag doped CdS on a glass slide by simple and economical chemical bath deposition at room temperature. The X-ray diffraction method analysis reveals that CdS thin films exhibit hexagonal structure when compared with standard JCPDS data. The estimated average crystallite size of the quantum dots and resulted in the least crystallite size of ˜9 nm. a comparison between the optical and electrical properties of the films before and after doping Ag was made through measuring and analyzing the curves for UV and I-V. From UV absorption spectra we observed that the samples exhibited a band edge near ˜400 nm with a slight deviation with the presence of excitonic peak for both CdS and Ag doped CdS. The presence of excitonic peak may be referred to the formation of quantum dots. The calculated band gap energy of thin films was found to be 3.45 eV and 3.15 eV for both CdS and Ag doped CdS thin films respectively, where the optical absorption spectra of Ag doped CdS nanoparticles also exhibit shift with respect to that of CdS quantum dots thin films. The photosensitive of CdS thin films show an increase in photocurrent when Ag doped CdS.

  9. Hexagonal pencil-like CdS nanorods: Facile synthesis and enhanced visible light photocatalytic performance

    NASA Astrophysics Data System (ADS)

    An, Liang; Wang, Guanghui; Zhao, Lei; Zhou, Yong; Gao, Fang; Cheng, Yang

    2015-07-01

    In the present study, hexagonal pencil-like CdS nanorods have been successfully synthesized through a typical facile and economical one-step hydrothermal method without using any surfactant or template. The product was characterized by X-ray powder diffraction (XRD), field-emission scanning electron microscopy (FE-SEM) and energy dispersive analysis of X-ray (EDX). The results revealed that the prepared CdS photocatalyst consisted of a large quantity of straight and smooth solid hexagonal nanorods and a few nanoparticles. The photocatalytic activities of CdS nanorods and commercial CdS powders were investigated by the photodegradation of Orange II (OII) in aqueous solution under visible light, and the CdS nanorods presented the highest photocatalytic activity. Its photocatalytic efficiency enhancement was attributed to the improved transmission of photogenerated electron-hole pairs in the CdS nanostructures. The present findings may provide a facile approach to synthesize high efficient CdS photocatalysts.

  10. Ultrasound-assisted microwave preparation of Ag-doped CdS nanoparticles.

    PubMed

    Ma, Jun; Tai, Guo'an; Guo, Wanlin

    2010-03-01

    Ag-doped CdS nanoparticles were synthesized by an ultrasound-assisted microwave synthesis method. The X-ray diffraction patterns reveal a structural evolution from cubic to hexagonal with increasing molar ratios of Ag(+)/Cd(2+) from 0% to 5%. It shows that the Ag-doped hexagonal CdS nanoparticles are polycrystal. The X-ray photoelectron spectroscopy of the CdS nanoparticles doping with 5% Ag(+) shows that the doped Ag in CdS is metallic. Simultaneously, the characteristic Raman peaks of the CdS nanoparticles enhance with increasing Ag(+) concentrations. The photocatalytic activity of different Ag-doped samples show a reasonable change due to different ratios of Ag which doped into CdS. Copyright 2009 Elsevier B.V. All rights reserved.

  11. Nitrogen and sulfur co-doped carbon dots with strong blue luminescence.

    PubMed

    Ding, Hui; Wei, Ji-Shi; Xiong, Huan-Ming

    2014-11-21

    Sulfur-doped carbon dots (S-CDs) with a quantum yield (QY) of 5.5% and nitrogen, sulfur co-doped carbon dots (N,S-CDs) with a QY of 54.4% were synthesized, respectively, via the same hydrothermal route using α-lipoic acid as the carbon source. The obtained S-CDs and N,S-CDs had similar sizes but different optical features. The QY of N,S-CDs was gradually enhanced when extending the reaction time to increase the nitrogen content. After careful characterization of these CDs, the doped nitrogen element was believed to be in the form of C=N and C-N bonds which enhanced the fluorescence efficiency significantly. Meanwhile, the co-doped sulfur element was found to be synergistic for nitrogen doping in N,S-CDs. The optimal N,S-CDs were successfully employed as good multicolor cell imaging probes due to their fine dispersion in water, excitation-dependent emission, excellent fluorescence stability and low toxicity. Besides, such N,S-CDs showed a wide detection range and excellent accuracy as fluorescent sensors for Fe(3+) ions.

  12. Chemical Synthesis and Optical Properties of CdS Poly(Lactic Acid) Nanocomposites and Their Transparent Fluorescent Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Cai-Feng; Cheng, Yu-Peng; Xie, He-Yi

    2011-01-01

    This paper describes the chemical synthesis of cadmium sulfide (CdS) polymer nanocomposites by covalently grafting poly(lactic acid) (PLA) onto the surfaces of CdS nanocrystals (NCs). Synthesis of the nanocomposites involved two steps. Lactic acid (LA) capped CdS NCs were first prepared by reacting cadmium chloride (CdCl2) with sodium sulfide (Na2S) using LA as the organic ligand in H2O/N,N-dimethylformamide (DMF) solution. Next CdS PLA nanocomposites were formed by in situ ring-opening polymerization of lactide on the surface of modified CdS NCs. Transparent fluorescent films were then successfully prepared by blending as-prepared CdS PLA nanocomposites with high-molecular-weight PLA. The as-prepared CdS NCsmore » and their nanocomposites were studied by transmission electron microscopic imaging, thermogravimetric analyses, and spectroscopic measurements (ultraviolet-visible absorption and photoluminescence). The spectroscopic studies revealed that the CdS polymer nanocomposites exhibited good optical properties in terms of their photoluminescence and transparency.« less

  13. Preparation and characterization of photocatalytic carbon dots-sensitized electrospun titania nanostructured fibers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Haopeng; Zhu, Yihua, E-mail: yhzhu@ecust.edu.cn; Cao, Huimin

    2013-02-15

    Graphical abstract: Display Omitted Highlights: ► The TiO{sub 2}-CDs nanostructured fibers are fabricated by using APS combining the electrospinning TiO{sub 2} nanostructured fibers and CDs. ► The CD can work as a photosensitizer in the degradation of rhodamine B under visible light irradiation. ► The TiO{sub 2}-CDs nanostructured fibers exhibit enhanced photocatalytic efficiency and can be easily handled and recycled. -- Abstract: The carbon dots (CDs) are new functional carbon-aceous materials. Compared to conventional dye molecules and semiconductor quantum dots, CDs are superior in chemical inertness and low toxicity. The TiO{sub 2}-CDs nanostructured fibers were fabricated by combining the electrospinningmore » technique and reflux method. Compared with the pure TiO{sub 2} nanostructured fibers and P25, the TiO{sub 2}-CDs nanostructured fibers exhibited enhanced photocatalytic efficiency of photodegradation of rhodamine B (RhB) under visible light irradiation. The enhanced photocatalytic activity of TiO{sub 2}-CDs nanostructured fibers could be attributed to the presence of CDs embedded in TiO{sub 2} nanostructured fibers. The CD can work as a photosensitizer in the degradation. Furthermore, the TiO{sub 2}-CDs nanostructured fibers could be easily handled and recycled due to their one-dimensional nanostructural property.« less

  14. The effect of a computerized prescribing and calculating system on hypo- and hyperglycemias and on prescribing time efficiency in neonatal intensive care patients.

    PubMed

    Maat, Barbara; Rademaker, Carin M A; Oostveen, Marloes I; Krediet, Tannette G; Egberts, Toine C G; Bollen, Casper W

    2013-01-01

    Prescribing glucose requires complex calculations because glucose is present in parenteral and enteral nutrition and drug vehicles, making it error prone and contributing to the burden of prescribing errors. Evaluation of the impact of a computerized physician order entry (CPOE) system with clinical decision support (CDS) for glucose control in neonatal intensive care patients (NICU) focusing on hypo- and hyperglycemic episodes and prescribing time efficiency. An interrupted time-series design to examine the effect of CPOE on hypo- and hyperglycemias and a crossover simulation study to examine the influence of CPOE on prescribing time efficiency. NICU patients at risk for glucose imbalance hospitalized at the University Medical Center Utrecht during 2001-2007 were selected. The risks of hypo- and hyperglycemias were expressed as incidences per 100 patient days in consecutive 3-month intervals during 3 years before and after CPOE implementation. To assess prescribing time efficiency, time needed to calculate glucose intake with and without CPOE was measured. No significant difference was found between pre- and post-CPOE mean incidences of hypo- and hyperglycemias per 100 hospital days of neonates at risk in every 3-month period (hypoglycemias, 4.0 [95% confidence interval, 3.2-4.8] pre-CPOE and 3.1 [2.7-3.5] post-CPOE, P = .88; hyperglycemias, 6.0 [4.3-7.7] pre-CPOE and 5.0 [3.7-6.3] post-CPOE, P = .75). CPOE led to a significant time reduction of 16% (1.3 [0.3-2.3] minutes) for simple and 60% (8.6 [5.1-12.1] minutes) for complex calculations. CPOE including a special CDS tool preserved accuracy for calculation and control of glucose intake and increased prescribing time efficiency.

  15. Active CdS/rGO photocatalyst by a high temperature gas-solid reaction for hydrogen production by splitting of water

    NASA Astrophysics Data System (ADS)

    Singh, Arvind; Sinha, A. S. K.

    2018-02-01

    rGO supported CdS photocatalysts has been prepared by a two steps method, i.e. impregnation of GO/rGO with CdSO4 followed by a high temperature reaction with H2S gas. Activity of this catalyst was superior to a catalyst of same composition prepared by commonly reported hydrothermal technique. Detailed microstructure studies were carried out using FTIR, PL, DRS, XRD, TEM, SAED, TPO and XPS. A much greater chemical interaction at the interface of CdS and rGO and also a higher absorption of visible light were observed in the reported catalyst. It has been concluded that the high temperature reaction with H2S has imparted n-type semiconductivity to CdS which with p-type rGO and synergy of chemical interaction at the interface has resulted into formation of a p-n hetrojunction. The formation of hetrojunction and high electron mobility of rGO has given a superior activity due to an efficient charge separation to the catalyst prepared by the technique reported in this paper.

  16. Green synthesis of carbon dots originated from Lycii Fructus for effective fluorescent sensing of ferric ion and multicolor cell imaging.

    PubMed

    Sun, Xiaohan; He, Jiang; Yang, Shenghong; Zheng, Mingda; Wang, Yingying; Ma, Shuang; Zheng, Haipeng

    2017-10-01

    Green, economical and effective method was developed for synthesis of fluorescent carbon dots (CDs), using one-pot hydrothermal treatment of Lycii Fructus. Optical and structural properties of the CDs have been extensively studied by UV-visible and fluorescence spectroscopic, x-ray diffraction (XRD) techniques, transmission electron microscopy (TEM) and high resolution TEM (HRTEM). Surface functionality and composition of CDs has been illustrated by Fourier transform infrared spectroscopy (FTIR), x-ray photoelectron spectroscopy (XPS) spectra and elemental analysis. The fabricated CDs possess stable fluorescent properties. The fluorescent quantum yield of the CDs can reach 17.2%. The prepared CDs emitted a broad fluorescence between 415 and 545nm and their fluorescence was tuned by changing excitation wavelength. Meanwhile, the fluorescence intensity of the CDs could be significantly quenched by Fe 3+ (turn-off). The CDs exhibit captivating sensitivity and selectivity toward Fe 3+ with a linear range from 0 to 30μM and a detection limit of 21nM. The prepared CDs were successfully applied to the determination of Fe 3+ in the urine samples, the water samples from the from the Yellow River and living HeLa (Henrietta Lacks) cells. Moreover, the low-toxicity and excellent biocompatibility of the CDs were evaluated through MTT assay on HeLa cells. The CDs were also employed as fluorescent probes for multicolor imaging of HeLa cells successfully. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. CIC-DUX4 Induces Small Round Cell Sarcomas Distinct from Ewing Sarcoma.

    PubMed

    Yoshimoto, Toyoki; Tanaka, Miwa; Homme, Mizuki; Yamazaki, Yukari; Takazawa, Yutaka; Antonescu, Cristina R; Nakamura, Takuro

    2017-06-01

    CIC-DUX4 sarcoma (CDS) or CIC-rearranged sarcoma is a subcategory of small round cell sarcoma resembling the morphological phenotypes of Ewing sarcoma (ES). However, recent clinicopathologic and molecular genetic analyses indicate that CDS is an independent disease entity from ES. Few ancillary markers have been used in the differential diagnosis of CDS, and additional CDS-specific biomarkers are needed for more definitive classification. Here, we report the generation of an ex vivo mouse model for CDS by transducing embryonic mesenchymal cells (eMC) with human CIC-DUX4 cDNA. Recipient mice transplanted with eMC-expressing CIC-DUX4 rapidly developed an aggressive, undifferentiated sarcoma composed of small round to short spindle cells. Gene-expression profiles of CDS and eMC revealed upregulation of CIC-DUX4 downstream genes such as PEA3 family genes, Ccnd2, Crh , and Zic1 IHC analyses for both mouse and human tumors showed that CCND2 and MUC5AC are reliable biomarkers to distinguish CDS from ES. Gene silencing of CIC-DUX4 as well as Ccnd2, Ret , and Bcl2 effectively inhibited CDS tumor growth in vitro The CDK4/6 inhibitor palbociclib and the soft tissue sarcoma drug trabectedin also blocked the growth of mouse CDS. In summary, our mouse model provides important biological information about CDS and provides a useful platform to explore biomarkers and therapeutic agents for CDS. Cancer Res; 77(11); 2927-37. ©2017 AACR . ©2017 American Association for Cancer Research.

  18. Optical Properties of CdS Nanobelts and Nanosaws Synthesized by Thermal Evaporation Method

    NASA Astrophysics Data System (ADS)

    Peng, Zhi-wei; Zou, Bing-suo

    2012-04-01

    By a simple one-step H2-assisted thermal evaporation method, high quality CdS nanostructures have been successfully fabricated on Au coated Si substrates in large scale. The as-synthesized CdS nanostructures consisted of sword-like nanobelts and toothed nanosaws with a single-crystal hexagonal wurtzite structure. The deposition temperature played an important role in determining the size and morphology of the CdS nanostructures. A combination of vapor-liquid-solid and vapor-solid growth mechanisms were proposed to interpret the formation of CdS nanostructures. Photoluminescence measurement indicated that the nanobelts and nanosaws have a prominent green emission at about 512 nm, which is the band-to-band emission of CdS. The waveguide characteristics of both types of CdS nanostructures were observed and discussed.

  19. Biomolecule-assisted construction of cadmium sulfide hollow spheres with structure-dependent photocatalytic activity.

    PubMed

    Wei, Chengzhen; Zang, Wenzhe; Yin, Jingzhou; Lu, Qingyi; Chen, Qun; Liu, Rongmei; Gao, Feng

    2013-02-25

    In this study, we report the synthesis of monodispersive solid and hollow CdS spheres with structure-dependent photocatalytic abilities for dye photodegradation. The monodispersive CdS nanospheres were constructed with the assistance of the soulcarboxymthyi chitosan biopolymer under hydrothermal conditions. The solid CdS spheres were corroded by ammonia to form hollow CdS nanospheres through a dissolution-reprecipitation mechanism. Their visible-light photocatalytic activities were investigated, and the results show that both the solid and the hollow CdS spheres have visible-light photocatalytic abilities for the photodegradation of dyes. The photocatalytic properties of the CdS spheres were demonstrated to be structure dependent. Although the nanoparticles comprising the hollow spheres have larger sizes than those comprising the solid spheres, the hollow CdS spheres have better photocatalytic performances than the solid CdS spheres, which can be attributed to the special hollow structure. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Resonance Rayleigh scattering technique for simple and sensitive analysis of tannic acid with carbon dots

    NASA Astrophysics Data System (ADS)

    Shi, Ying; Yang, Liu; Zhu, Jinghui; Yang, Jidong; Liu, Shaopu; Qiao, Man; Duan, Ruilin; Hu, Xiaoli

    2017-02-01

    Carbon dots (CDs) are raising a substantial amount of attention owing to their many unique and novel physicochemical properties. Herein one-pot synthesized CDs, to the best of our knowledge, were first served as the robust nanoprobe for detection tannic acid (TA) based on resonance Rayleigh scattering technique. The as-prepared CDs can combine with TA via hydrogen bond, resulting in remarkable enhancement of scattering signal with no changes in the fluorescence of CDs. Therefore, a novel protocol for TA determination was established and this strategy allowed quantitative detection of TA in the linear range of 0.2-10.0 μmol L- 1 with an excellent detection limit of 9.0 nmol L- 1. Moreover, the CDs based nanoprobe can be applied to the determination of TA in water sample with satisfactory results. Our study can potentially influence our current views on CDs and particularly impressive and offers new insights into application of CDs beyond the traditional understanding of CDs.

  1. Doxorubicin conjugated functionalizable carbon dots for nucleus targeted delivery and enhanced therapeutic efficacy

    NASA Astrophysics Data System (ADS)

    Yang, Lei; Wang, Zheran; Wang, Ju; Jiang, Weihua; Jiang, Xuewei; Bai, Zhaoshi; He, Yunpeng; Jiang, Jianqi; Wang, Dongkai; Yang, Li

    2016-03-01

    Carbon dots (CDs) have shown great potential in imaging and drug/gene delivery applications. In this work, CDs functionalized with a nuclear localization signal peptide (NLS-CDs) were employed to transport doxorubicin (DOX) into cancer cells for enhanced antitumor activity. DOX was coupled to NLS-CDs (DOX-CDs) through an acid-labile hydrazone bond, which was cleavable in the weakly acidic intracellular compartments. The cytotoxicity of DOX-CD complexes was evaluated by the MTT assay and the cellular uptake was monitored using flow cytometry and confocal laser scanning microscopy. Cell imaging confirmed that DOX-CDs were mainly located in the nucleus. Furthermore, the complexes could efficiently induce apoptosis in human lung adenocarcinoma A549 cells. The in vivo therapeutic efficacy of DOX-CDs was investigated in an A549 xenograft nude mice model and the complexes exhibited an enhanced ability to inhibit tumor growth compared with free DOX. Thus, the DOX-CD conjugates may be exploited as promising drug delivery vehicles in cancer therapy.Carbon dots (CDs) have shown great potential in imaging and drug/gene delivery applications. In this work, CDs functionalized with a nuclear localization signal peptide (NLS-CDs) were employed to transport doxorubicin (DOX) into cancer cells for enhanced antitumor activity. DOX was coupled to NLS-CDs (DOX-CDs) through an acid-labile hydrazone bond, which was cleavable in the weakly acidic intracellular compartments. The cytotoxicity of DOX-CD complexes was evaluated by the MTT assay and the cellular uptake was monitored using flow cytometry and confocal laser scanning microscopy. Cell imaging confirmed that DOX-CDs were mainly located in the nucleus. Furthermore, the complexes could efficiently induce apoptosis in human lung adenocarcinoma A549 cells. The in vivo therapeutic efficacy of DOX-CDs was investigated in an A549 xenograft nude mice model and the complexes exhibited an enhanced ability to inhibit tumor growth compared with free DOX. Thus, the DOX-CD conjugates may be exploited as promising drug delivery vehicles in cancer therapy. Electronic supplementary information (ESI) available: FT-IR and 1H NMR spectra of DOX-CD complexes. See DOI: 10.1039/c6nr00247a

  2. Facile synthesis of silver nanoparticles/carbon dots for a charge transfer study and peroxidase-like catalytic monitoring by surface-enhanced Raman scattering

    NASA Astrophysics Data System (ADS)

    Zhao, Hongyue; Guo, Yue; Zhu, Shoujun; Song, Yubin; Jin, Jing; Ji, Wei; Song, Wei; Zhao, Bing; Yang, Bai; Ozaki, Yukihiro

    2017-07-01

    In this work, carbon dots (CDs) were combined with Ag nanoparticles (NPs) by a chemical reaction to form Ag NPs/CDs hybrid, which was then used as a novel surface-enhanced Raman scattering (SERS) substrate. During the synthetic process, carboxyl groups on the surface of Ag NPs were reacted with amino groups of CDs in an amidation reaction. The D and G bands of CDs in the Ag NPs/CDs hybrid could be easily detected by SERS. By employing p-aminothiophenol (PATP) molecules as SERS probes, the Ag NPs/CDs hybrid substrate could detect PATP in diluted solutions of concentration as low as 10-9 M. The charge transfer (CT) effect on SERS spectra with different excitation wavelengths in the prepared Ag NPs/CDs hybrid and PATP system was also investigated. It was found that addition of CDs changes the degree of CT between Ag NPs and PATP molecules. Since the prepared Ag NPs/CDs hybrid also showed a peroxidase-like activity toward the oxidation of 3,3‧,5,5‧-tetramethylbenzidine using H2O2, which can provide the sensitive detection of H2O2 by SERS technique.

  3. Optimal nitrogen and phosphorus codoping carbon dots towards white light-emitting device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Feng; Wang, Yaling; Miao, Yanqin

    Through a one-step fast microwave-assisted approach, nitrogen and phosphorus co-doped carbon dots (N,P-CDs) were synthesized using ammonium citrate (AC) as a carbon source and phosphates as additive reagent. Under the condition of an optimal reaction time of 140 s, the influence of additive with different N and P content on fluorescent performance of N,P-CDs was further explored. It was concluded that high nitrogen content and moderate phosphorus content are necessary for obtaining high quantum yield (QY) N,P-CDs, among which the TAP-CDs (CDs synthesized using ammonium phosphate as additive reagent) show high quantum yield (QY) of 62% and red-green-blue (RGB) spectral compositionmore » of 51.67%. Besides, the TAP-CDs exhibit satisfying thermal stability within 180 °C. By virtue of good optical and thermal properties of TAP-CDs, a white light-emitting device (LED) was fabricated by combining ultraviolet chip with TAP-CDs as phosphor. The white LED emits bright warm-white light with the CIE chromaticity coordinate of (0.38, 0.35) and the corresponding color temperature (CCT) of 4450 K, indicating the potential of TAP-CDs phosphor in white LED.« less

  4. Highly Efficient Carbon Dots with Reversibly Switchable Green-Red Emissions for Trichromatic White Light-Emitting Diodes.

    PubMed

    Yuan, Biao; Guan, Shanyue; Sun, Xingming; Li, Xiaoming; Zeng, Haibo; Xie, Zheng; Chen, Ping; Zhou, Shuyun

    2018-05-09

    Carbon dots (CDs) have potentials to be utilized in optoelectronic devices, bioimaging, and photocatalysis. The majority of the current CDs with high quantum yield to date were limited in the blue light emission region. Herein, on the basis of surface electron-state engineering, we report a kind of CDs with reversible switching ability between green and red photoluminescence with a quantum yield (QY) of both up to 80%. Highly efficient green and red solid-state luminescence is realized by doping CDs into a highly transparent matrix of methyltriethoxysilane and 3-triethoxysilylpropylamine to form CDs/gel glasses composites with QYs of 80 and 78%. The CDs/gel glasses show better transmittance in visible light bands and excellent thermal stability. A blue-pumped CDs/gel glasses phosphor-based trichromatic white light-emitting diode (WLED) is realized, whose color rendering index is 92.9. The WLED gets the highest luminous efficiency of 71.75 lm W -1 in CDs-based trichromatic WLEDs. This work opens a door for developing highly efficient green- and red-emissive switching CDs which were used as phosphors for WLEDs and have the tendency for applications in other fields, such as sensing, bioimaging, and photocatalysis.

  5. US Gateway to SIMBAD Astronomical Database

    NASA Technical Reports Server (NTRS)

    Eichhorn, G.

    1998-01-01

    During the last year the US SIMBAD Gateway Project continued to provide services like user registration to the US users of the SIMBAD database in France. User registration is required by the SIMBAD project in France. Currently, there are almost 3000 US users registered. We also provide user support by answering questions from users and handling requests for lost passwords. We have worked with the CDS SIMBAD project to provide access to the SIMBAD database to US users on an Internet address basis. This will allow most US users to access SIMBAD without having to enter passwords. This new system was installed in August, 1998. The SIMBAD mirror database at SAO is fully operational. We worked with the CDS to adapt it to our computer system. We implemented automatic updating procedures that update the database and password files daily. This mirror database provides much better access to the US astronomical community. We also supported a demonstration of the SIMBAD database at the meeting of the American Astronomical Society in January. We shipped computer equipment to the meeting and provided support for the demonstration activities at the SIMBAD booth. We continued to improve the cross-linking between the SIMBAD project and the Astro- physics Data System. This cross-linking between these systems is very much appreciated by the users of both the SIMBAD database and the ADS Abstract Service. The mirror of the SIMBAD database at SAO makes this connection faster for the US astronomers. The close cooperation between the CDS in Strasbourg and SAO, facilitated by this project, is an important part of the astronomy-wide digital library initiative called Urania. It has proven to be a model in how different data centers can collaborate and enhance the value of their products by linking with other data centers.

  6. SSBRP User Operations Facility (UOF) Overview and Development Strategy

    NASA Technical Reports Server (NTRS)

    Picinich, Lou; Stone, Thom; Sun, Charles; Windrem, May; Givens, John J. (Technical Monitor)

    1995-01-01

    This paper will present the Space Station Biological Research Project (SSBRP) User Operations Facility (UOF) architecture and development strategy. A major element of the UOF at NASA Ames Research Center, the Communication and Data System (CDS) will be the primary focus of the discussions. CDS operational, telescience, security, and development objectives will be discussed along with CDS implementation strategy. The implementation strategy discussions will include: Object Oriented Analysis & Design, System & Software Prototyping, and Technology Utilization. A CDS design overview that includes: CDS Context Diagram, CDS Architecture, Object Models, Use Cases, and User Interfaces will also be presented. CDS development brings together "cutting edge" technologies and techniques such as: object oriented development, network security, multimedia networking, web-based data distribution, JAVA, and graphical user interfaces. Use of these "cutting edge" technologies and techniques translates directly to lower development and operations costs.

  7. Blocking the Formation of Zn2+/Dye Complexes in Dye-Sensitized Solar Cells by Inserting CdS Quantum Dots into Sandwich Layer

    NASA Astrophysics Data System (ADS)

    Sun, Yunfei; Liu, Chunling; Yang, Lili; Wei, Maobin; Lv, Shiquan; Sui, Yingrui; Cao, Jian; Chen, Gang; Yang, Jinghai

    2018-06-01

    ZnO NRAs are grown on ITO substrates by a simple chemical method. CdS QDs were deposited on ZnO NRAs by SILAR. N719 was synthesized by dipping method. J-V analysis indicates that by inserting a layer of CdS QDs, the conversion efficiency of DSSCs was improved obviously. The device with CdS QDs shows the higher conversion efficiency due to the three reasons: (1) CdS QDs enhanced adsorption spectra of DSSCs in the visible region; (2) CdS QDs block the formation of Zn2+/dye complex, it is beneficial for electros transport from dye to ZnO photoanode. It is the key to obtain higher conversion efficiency; (3) FRET dynamics exists by the introduction of CdS QDs.

  8. Facile and eco-friendly synthesis of green fluorescent carbon nanodots for applications in bioimaging, patterning and staining

    NASA Astrophysics Data System (ADS)

    Shi, Lihong; Li, Yanyan; Li, Xiaofeng; Wen, Xiangping; Zhang, Guomei; Yang, Jun; Dong, Chuan; Shuang, Shaomin

    2015-04-01

    We report a facile and eco-friendly strategy for the fabrication of green fluorescent carbon nanodots (CDs), and demonstrate their applications for bio-imaging, patterning, and staining. A one-pot hydrothermal method using various plant petals yields bright green-emitting CDs, providing an easy way for the production of green fluorescent CDs without the need for a tedious synthetic methodology or the use of toxic/expensive solvents and starting materials. The as-prepared CDs show small size distribution and excellent dispersibility. Their strong green fluorescence is observed when the excitation wavelength is between 430 nm and 490 nm. Moreover, they exhibit high tolerance to various external conditions, such as pH values, external cations, and continuous excitation. Due to minimum toxicity as well as good photoluminescence properties, these CDs can be applied to in vitro and in vivo imaging, patterning, and staining. According to confocal fluorescence imaging of human uterine cervical squamous cell carcinoma cells, CDs penetrate into the cell and enter the cytoplasm and the nucleus. More strikingly, carp is directly fed with CDs for in vivo imaging and shows bright green fluorescence at an excitation wavelength of 470 nm. In addition, the obtained CDs are used as fluorescent inks for drawing luminescence patterns. Finally, we also apply the CDs as a fluorescent dye. Interestingly, the absorbent filter paper with staining emits dramatic fluorescence under 470 nm excitation.We report a facile and eco-friendly strategy for the fabrication of green fluorescent carbon nanodots (CDs), and demonstrate their applications for bio-imaging, patterning, and staining. A one-pot hydrothermal method using various plant petals yields bright green-emitting CDs, providing an easy way for the production of green fluorescent CDs without the need for a tedious synthetic methodology or the use of toxic/expensive solvents and starting materials. The as-prepared CDs show small size distribution and excellent dispersibility. Their strong green fluorescence is observed when the excitation wavelength is between 430 nm and 490 nm. Moreover, they exhibit high tolerance to various external conditions, such as pH values, external cations, and continuous excitation. Due to minimum toxicity as well as good photoluminescence properties, these CDs can be applied to in vitro and in vivo imaging, patterning, and staining. According to confocal fluorescence imaging of human uterine cervical squamous cell carcinoma cells, CDs penetrate into the cell and enter the cytoplasm and the nucleus. More strikingly, carp is directly fed with CDs for in vivo imaging and shows bright green fluorescence at an excitation wavelength of 470 nm. In addition, the obtained CDs are used as fluorescent inks for drawing luminescence patterns. Finally, we also apply the CDs as a fluorescent dye. Interestingly, the absorbent filter paper with staining emits dramatic fluorescence under 470 nm excitation. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr00783f

  9. Translation and validation of the Cardiac Depression Scale to Arabic.

    PubMed

    Papasavvas, T; Al-Amin, H; Ghabrash, H F; Micklewright, D

    2016-08-01

    The Cardiac Depression Scale (CDS) has been designed to measure depressive symptoms in patients with heart disease. There is no Arabic version of the CDS. We translated and validated the CDS in an Arabic sample of patients with heart disease. Forward and back translation of the CDS was followed by assessment of cultural relevance and content validity. The Arabic version of the CDS (A-CDS) and the Arabic version of the Hospital Anxiety and Depression Scale (A-HADS) were then administered to 260 Arab in-patients with heart disease from 18 Arabic countries. Construct validity was assessed using exploratory factor analysis with polychoric correlations. Internal consistency was assessed using ordinal reliability alpha and item-to-factor polychoric correlations. Concurrent validity was assessed using Pearson's correlation coefficient between the A-CDS and the depression subscale of the A-HADS (A-HADS-D). Cultural relevance and content validity of the A-CDS were satisfactory. Exploratory factor analysis revealed three robust factors, without cross-loadings, that formed a single dimension. Internal consistency was high (ordinal reliability alpha for the total scale and the three factors were .94, .91, .86, and .87, respectively; item-to-factor correlations ranged from .77 to .91). Concurrent validity was high (r=.72). The A-CDS demonstrated a closer to normal distribution of scores than the A-HADS-D. Sensitivity and specificity of the A-CDS were not objectively assessed. The A-CDS appears to be a valid and reliable instrument to measure depressive symptoms in a representative sample of Arab in-patients with heart disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Effectiveness of a novel and scalable clinical decision support intervention to improve venous thromboembolism prophylaxis: a quasi-experimental study.

    PubMed

    Umscheid, Craig A; Hanish, Asaf; Chittams, Jesse; Weiner, Mark G; Hecht, Todd E H

    2012-08-31

    Venous thromboembolism (VTE) causes morbidity and mortality in hospitalized patients, and regulators and payors are encouraging the use of systems to prevent them. Here, we examine the effect of a computerized clinical decision support (CDS) intervention implemented across a multi-hospital academic health system on VTE prophylaxis and events. The study included 223,062 inpatients admitted between April 2007 and May 2010, and used administrative and clinical data. The intervention was integrated into a commercial electronic health record (EHR) in an admission orderset used for all admissions. Three time periods were examined: baseline (period 1), and the time after implementation of the first CDS intervention (period 2) and a second iteration (period 3). Providers were prompted to accept or decline prophylaxis based on patient risk. Time series analyses examined the impact of the intervention on VTE prophylaxis during time periods two and three compared to baseline, and a simple pre-post design examined impact on VTE events and bleeds secondary to anticoagulation. VTE prophylaxis and events were also examined in a prespecified surgical subset of our population meeting the public reporting criteria defined by the Agency for Healthcare Research and Quality (AHRQ) Patient Safety Indicator (PSI). Unadjusted analyses suggested that "recommended", "any", and "pharmacologic" prophylaxis increased from baseline to the last study period (27.1% to 51.9%, 56.7% to 78.1%, and 42.0% to 54.4% respectively; p < 0.01 for all comparisons). Results were significant across all hospitals and the health system overall. Interrupted time series analyses suggested that our intervention increased the use of "recommended" and "any" prophylaxis by 7.9% and 9.6% respectively from baseline to time period 2 (p < 0.01 for both comparisons); and 6.6% and 9.6% respectively from baseline to the combined time periods 2 and 3 (p < 0.01 for both comparisons). There were no significant changes in "pharmacologic" prophylaxis in the adjusted model. The overall percent of patients with VTE increased from baseline to the last study period (2.0% to 2.2%; p = 0.03), but an analysis excluding patients with VTE "present on admission" (POA) demonstrated no difference in events (1.3% to 1.3%; p = 0.80). Overall bleeds did not significantly change. An analysis examining VTE prophylaxis and events in a surgical subset of patients defined by the AHRQ PSI demonstrated increased "recommended", "any", and "pharmacologic" prophylaxis from baseline to the last study period (32.3% to 60.0%, 62.8% to 85.7%, and 47.9% to 63.3% respectively; p < 0.01 for all comparisons) as well as reduced VTE events (2.2% to 1.7%; p < 0.01). The CDS intervention was associated with an increase in "recommended" and "any" VTE prophylaxis across the multi-hospital academic health system. The intervention was also associated with increased VTE rates in the overall study population, but a subanalysis using only admissions with appropriate POA documentation suggested no change in VTE rates, and a prespecified analysis of a surgical subset of our sample as defined by the AHRQ PSI for public reporting purposes suggested reduced VTE. This intervention was created in a commonly used commercial EHR and is scalable across institutions with similar systems.

  11. Effectiveness of a novel and scalable clinical decision support intervention to improve venous thromboembolism prophylaxis: a quasi-experimental study

    PubMed Central

    2012-01-01

    Background Venous thromboembolism (VTE) causes morbidity and mortality in hospitalized patients, and regulators and payors are encouraging the use of systems to prevent them. Here, we examine the effect of a computerized clinical decision support (CDS) intervention implemented across a multi-hospital academic health system on VTE prophylaxis and events. Methods The study included 223,062 inpatients admitted between April 2007 and May 2010, and used administrative and clinical data. The intervention was integrated into a commercial electronic health record (EHR) in an admission orderset used for all admissions. Three time periods were examined: baseline (period 1), and the time after implementation of the first CDS intervention (period 2) and a second iteration (period 3). Providers were prompted to accept or decline prophylaxis based on patient risk. Time series analyses examined the impact of the intervention on VTE prophylaxis during time periods two and three compared to baseline, and a simple pre-post design examined impact on VTE events and bleeds secondary to anticoagulation. VTE prophylaxis and events were also examined in a prespecified surgical subset of our population meeting the public reporting criteria defined by the Agency for Healthcare Research and Quality (AHRQ) Patient Safety Indicator (PSI). Results Unadjusted analyses suggested that “recommended”, “any”, and “pharmacologic” prophylaxis increased from baseline to the last study period (27.1% to 51.9%, 56.7% to 78.1%, and 42.0% to 54.4% respectively; p < 0.01 for all comparisons). Results were significant across all hospitals and the health system overall. Interrupted time series analyses suggested that our intervention increased the use of “recommended” and “any” prophylaxis by 7.9% and 9.6% respectively from baseline to time period 2 (p < 0.01 for both comparisons); and 6.6% and 9.6% respectively from baseline to the combined time periods 2 and 3 (p < 0.01 for both comparisons). There were no significant changes in “pharmacologic” prophylaxis in the adjusted model. The overall percent of patients with VTE increased from baseline to the last study period (2.0% to 2.2%; p = 0.03), but an analysis excluding patients with VTE “present on admission” (POA) demonstrated no difference in events (1.3% to 1.3%; p = 0.80). Overall bleeds did not significantly change. An analysis examining VTE prophylaxis and events in a surgical subset of patients defined by the AHRQ PSI demonstrated increased “recommended”, “any”, and “pharmacologic” prophylaxis from baseline to the last study period (32.3% to 60.0%, 62.8% to 85.7%, and 47.9% to 63.3% respectively; p < 0.01 for all comparisons) as well as reduced VTE events (2.2% to 1.7%; p < 0.01). Conclusions The CDS intervention was associated with an increase in “recommended” and “any” VTE prophylaxis across the multi-hospital academic health system. The intervention was also associated with increased VTE rates in the overall study population, but a subanalysis using only admissions with appropriate POA documentation suggested no change in VTE rates, and a prespecified analysis of a surgical subset of our sample as defined by the AHRQ PSI for public reporting purposes suggested reduced VTE. This intervention was created in a commonly used commercial EHR and is scalable across institutions with similar systems. PMID:22938083

  12. Facile synthesis of fluorescence carbon dots from sweet potato for Fe3+ sensing and cell imaging.

    PubMed

    Shen, Jie; Shang, Shaoming; Chen, Xiuying; Wang, Dan; Cai, Yan

    2017-07-01

    In this study, a facile synthesis of fluorescence carbon dots (CDs) from sweet potato was performed through hydrothermal treatment. The obtained CDs with quantum yield of 8.64% have good dispersibility due to the soluble functional groups on their surfaces. The characterization of CDs was carried out and their possible formation mechanism was also discussed. In addition, the cytotoxicity results showed that the CDs exhibit non toxicity within 100μg/mL. At this concentration, the CDs were applied in cell imaging, indicating that they are promising fluorescent probes for biological imaging. In addition, the fluorescence of CDs was quenched by Fe 3+ with a linear concentration of 1 to 100μM, associated with the limit of detection of 0.32μM. Subsequently, the CDs were successfully applied for Fe 3+ probing in living cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Red, green, and blue luminescence by carbon dots: full-color emission tuning and multicolor cellular imaging.

    PubMed

    Jiang, Kai; Sun, Shan; Zhang, Ling; Lu, Yue; Wu, Aiguo; Cai, Congzhong; Lin, Hengwei

    2015-04-27

    A facile approach for preparation of photoluminescent (PL) carbon dots (CDs) is reported. The three resulting CDs emit bright and stable red, green and blue (RGB) colors of luminescence, under a single ultraviolet-light excitation. Alterations of PL emission of these CDs are tentatively proposed to result from the difference in their particle size and nitrogen content. Interestingly, up-conversion (UC)PL of these CDs is also observed. Moreover, flexible full-color emissive PVA films can be achieved through mixing two or three CDs in the appropriate ratios. These CDs also show low cytotoxicity and excellent cellular imaging capability. The facile preparation and unique optical features make these CDs potentially useful in numerous applications such as light-emitting diodes, full-color displays, and multiplexed (UC)PL bioimaging. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Photo current generation in RGO - CdS nanorod thin film device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, Koushik; Chakrabarty, Sankalpita; Ibrahim, Sk.

    2016-05-23

    Herein, we report the synthesis and characterization of reduced graphene oxide (RGO) - cadmium sulfide (CdS) nanocomposite materials. The reduction of GO, formation of CdS and decoration of CdS onto RGO sheets were done in a one- pot solvothermal process. We have observed that the PL intensity for CdS nanorods remarkably quenched after the attachment of RGO, which established the photo induced charge transformation from the CdS nanorod to RGO sheets through the RGO-CdS interface. The optoelectronic transport properties of our fabricated large area thin film device exhibits excellent photo induced charge generation under simulated solar light illumination. The photomore » sensitivity of the device increases linearly with the increase of illuminated light intensity. The RGO-CdS composite exhibits enhance photocatalytic dye degradation efficiency in compare to control CdS under simulated solar light illumination.« less

  15. A Second Life for CDs

    ERIC Educational Resources Information Center

    Snoderly, Kathleen

    2011-01-01

    Cutting a few CDs apart with scissors, the author found that the process created somewhat brittle shards. As a result, she started to paint a few with acrylic, finding to her amazement that the paint gave the CDs a leathery, more manageable texture. Upon further experimentation, she found that if the CDs are painted somewhat translucently in…

  16. 77 FR 13668 - Self-Regulatory Organizations; Chicago Mercantile Exchange, Inc.; Order Approving Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-07

    ... calculates each CDS Clearing Member's allocation to the CDS Guaranty Fund, with a new standard that CME believes better allocates tail risk. Currently CME rules provide that each CDS Clearing Member's allocation... that the allocation will be made on the basis of each CDS Clearing Member's potential residual loss...

  17. Improved delivery through biological membranes. XXXL: Solubilization and stabilization of an estradiol chemical delivery system by modified beta-cyclodextrins.

    PubMed

    Brewster, M E; Estes, K S; Loftsson, T; Perchalski, R; Derendorf, H; Mullersman, G; Bodor, N

    1988-11-01

    A dihydropyridine in equilibrium pyridinium salt chemical delivery system (CDS) for estradiol (E2CDS) was complexed with various modified beta-cyclodextrins including hydroxyethyl-beta-cyclodextrin (HECD), hydroxypropyl-beta-cyclodextrin (HPCD), and heptakis(2,6-di-O-methyl)-beta-cyclodextrin (DMCD). Complex formation with all of these cyclodextrins resulted in dramatic increases in the water solubility of E2CDS. Studies on the complex of E2CDS and HPCD (E2CDS-CD) indicated that the encapsulated estrogen was approximately four times more stable than the unmanipulated CDS, producing an estimated half-life of degradation of 4 years compared with 1.2 years for the uncomplexed drug at room temperature. The complexation of E2CDS and HPCD also stabilized the dihydronicotinate in solutions containing potassium ferricyanide. This formulation was shown to be equivalent to E2CDS in dimethyl sulfoxide in delivering the oxidized, estradiol precursor (E2Q+) to the brain, and also produced similar biological responses; these included decreased luteinizing hormone (LH) secretion and a decrease in the rate of weight gain in castrated female rats.

  18. High fidelity polycrystalline CdTe/CdS heterostructures via molecular dynamics

    DOE PAGES

    Aguirre, Rodolfo; Chavez, Jose Juan; Zhou, Xiaowang; ...

    2017-06-20

    Molecular dynamics simulations of polycrystalline growth of CdTe/CdS heterostructures have been performed. First, CdS was deposited on an amorphous CdS substrate, forming a polycrystalline film. Subsequently, CdTe was deposited on top of the polycrystalline CdS film. Cross-sectional images show grain formation at early stages of the CdS growth. During CdTe deposition, the CdS structure remains almost unchanged. Concurrently, CdTe grain boundary motion was detected after the first 24.4 nanoseconds of CdTe deposition. With the elapse of time, this grain boundary pins along the CdS/CdTe interface, leaving only a small region of epitaxial growth. CdTe grains are larger than CdS grainsmore » in agreement with experimental observations in the literature. Crystal phase analysis shows that zinc blende structure dominates over the wurtzite structure inside both CdS and CdTe grains. Composition analysis shows Te and S diffusion to the CdS and CdTe films, respectively. Lastly, these simulated results may stimulate new ideas for studying and improving CdTe solar cell efficiency.« less

  19. Carbon dots decorated magnetic ZnFe2O4 nanoparticles with enhanced adsorption capacity for the removal of dye from aqueous solution

    NASA Astrophysics Data System (ADS)

    Shi, Weilong; Guo, Feng; Wang, Huibo; Liu, Changan; Fu, Yijun; Yuan, Songliu; Huang, Hui; Liu, Yang; Kang, Zhenhui

    2018-03-01

    Widely used synthetic dyes have been caused serious environmental pollution. Therefore, it is imperative to acquire highly efficient adsorbent to remove them. Here, we report the carbon dots/ZnFe2O4 (CDs/ZFO) composites were prepared through a facile hydrothermal route for absorption removal of dye from aqueous solution. The characterizations reveal the CDs were uniformly deposited on the surfaces of ZFO nanoparticles in the composite. The CDs/ZFO composites as adsorbents exhibit enhanced adsorption behavior for methyl orange (MO) in comparison of pristine ZFO, in which the 5% CDs/ZFO (with the CDs mass content of 5 wt%) shows the highest absorption activity. Experimental studies on adsorption isotherms of MO over the 5% CDs/ZFO composite indicate that experimental data were found to follow Langmuir model with a monolayer adsorption capacity of 181.2 mg g-1. The corresponding adsorption kinetics was fitted well with the pseudo-second-order kinetic model. Moreover, thermodynamics parameters including ΔG°, ΔH° and ΔS° were tested, demonstrating that the adsorption of MO over CDs/ZFO composite was spontaneous and exothermic in nature. The remarkably increased adsorption performance of CDs/ZFO composites can be attributed to abundant oxygen-containing groups on the surface of CDs.

  20. Effects of bacteria on CdS thin films used in technological devices

    NASA Astrophysics Data System (ADS)

    Alpdoğan, S.; Adıgüzel, A. O.; Sahan, B.; Tunçer, M.; Metin Gubur, H.

    2017-04-01

    Cadmium sulfide (CdS) thin films were fabricated on glass substrates by the chemical bath deposition method at 70 {}^\\circ \\text{C} considering deposition times ranging from 2 h to 5 h. The optical band gaps of CdS thin films were found to be in the 2.42-2.37 eV range. CdS thin films had uniform spherical nano-size grains which had polycrystalline, hexagonal and cubic phases. The films had a characteristic electrical resistivity of the order of {{10}5} Ω \\text{cm} and n-type conductivity at room condition. CdS thin films were incubated in cultures of B.domonas aeruginosa and Staphylococcus aureus, which exist abundantly in the environment, and form biofilms. SEM images showed that S. aureus and K. pneumonia were detected significantly on the film surfaces with a few of P. aeruginosa and B. subtilis cells attached. CdS thin film surface exhibits relatively good resistance to the colonization of P. aeruginosa and B. subtilis. Optical results showed that the band gap of CdS thin films which interacted with the bacteria is 2.42 \\text{eV} . The crystal structure and electrical properties of CdS thin films were not affected by bacterial adhesion. The antimicrobial effect of CdS nanoparticles was different for different bacterial strains.

  1. Controllable synthesis of green and blue fluorescent carbon nanodots for pH and Cu(2+) sensing in living cells.

    PubMed

    Shi, Lihong; Li, Yanyan; Li, Xiaofeng; Zhao, Bo; Wen, Xiangping; Zhang, Guomei; Dong, Chuan; Shuang, Shaomin

    2016-03-15

    We report a controllable strategy for fabrication of green and blue fluorescent carbon nanodots (CDs), and demonstrate their applications for pH and Cu(2+) sensing in living cells. Green and blue fluorescent CDs have been synthesized by hydrothermal method and pyrolysis of leeks, respectively, providing an easy way for the production of CDs without the request of tedious synthetic methodology or the use of toxic/expensive solvents and starting materials. Green fluorescent CDs (G-CDs) exhibit high tolerance to pH values and external cations. Blue fluorescent CDs (B-CDs) can be applied to pH and Cu(2+) sensing. The linear range of Cu(2+) detection is 0.01-10.00 μM and the detection limit is 0.05 μM. For pH detection, there is a good linearity in the pH range of 3.5-10.0. The linear and rapid response of B-CDs to Cu(2+) and pH is valuable for Cu(2+) and pH sensing in living cells. Confocal fluorescent imaging of human cervical carcinoma cells indicates that B-CDs could visualize Cu(2+) and pH fluctuations in living cells with negligible autofluorescence. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. In vivo characterization of hair and skin derived carbon quantum dots with high quantum yield as long-term bioprobes in zebrafish

    PubMed Central

    Zhang, Jing-Hui; Niu, Aping; Li, Jing; Fu, Jian-Wei; Xu, Qun; Pei, De-Sheng

    2016-01-01

    Carbon quantum dots (CDs) were widely investigated because of their tunable fluorescence properties and low toxicity. However, so far there have been no reports on in vivo functional studies of hair and skin derived CDs. Here, hair derived CDs (HCDs) and skin derived CDs (SCDs) were produced by using human hair and pig skin as precursors. The quantum yields (QYs) of HCDs and SCDs were quite high, compared to citric acid derived CDs (CCDs). HCDs and SCDs possess optimal photostability, hypotoxicity and biocompatibility in zebrafish, indicating that HCDs and SCDs possess the capacity of being used as fluorescence probes for in vivo biological imaging. The long-time observation for fluorescence alternation of CDs in zebrafish and the quenching assay of CDs by ATP, NADH and Fe3+ ions demonstrated that the decaying process of CDs in vivo might be induced by the synergistic effect of the metabolism process. All results indicated that large batches and high QYs of CDs can be acquired by employing natural and nontoxic hair and skin as precursors. To our knowledge, this is the first time to report SCDs, in vivo comparative studies of HCDs, SCDs and CCDs as bioprobes, and explore their mechanism of photostability in zebrafish. PMID:27886267

  3. In vivo characterization of hair and skin derived carbon quantum dots with high quantum yield as long-term bioprobes in zebrafish.

    PubMed

    Zhang, Jing-Hui; Niu, Aping; Li, Jing; Fu, Jian-Wei; Xu, Qun; Pei, De-Sheng

    2016-11-25

    Carbon quantum dots (CDs) were widely investigated because of their tunable fluorescence properties and low toxicity. However, so far there have been no reports on in vivo functional studies of hair and skin derived CDs. Here, hair derived CDs (HCDs) and skin derived CDs (SCDs) were produced by using human hair and pig skin as precursors. The quantum yields (QYs) of HCDs and SCDs were quite high, compared to citric acid derived CDs (CCDs). HCDs and SCDs possess optimal photostability, hypotoxicity and biocompatibility in zebrafish, indicating that HCDs and SCDs possess the capacity of being used as fluorescence probes for in vivo biological imaging. The long-time observation for fluorescence alternation of CDs in zebrafish and the quenching assay of CDs by ATP, NADH and Fe 3+ ions demonstrated that the decaying process of CDs in vivo might be induced by the synergistic effect of the metabolism process. All results indicated that large batches and high QYs of CDs can be acquired by employing natural and nontoxic hair and skin as precursors. To our knowledge, this is the first time to report SCDs, in vivo comparative studies of HCDs, SCDs and CCDs as bioprobes, and explore their mechanism of photostability in zebrafish.

  4. In vivo characterization of hair and skin derived carbon quantum dots with high quantum yield as long-term bioprobes in zebrafish

    NASA Astrophysics Data System (ADS)

    Zhang, Jing-Hui; Niu, Aping; Li, Jing; Fu, Jian-Wei; Xu, Qun; Pei, De-Sheng

    2016-11-01

    Carbon quantum dots (CDs) were widely investigated because of their tunable fluorescence properties and low toxicity. However, so far there have been no reports on in vivo functional studies of hair and skin derived CDs. Here, hair derived CDs (HCDs) and skin derived CDs (SCDs) were produced by using human hair and pig skin as precursors. The quantum yields (QYs) of HCDs and SCDs were quite high, compared to citric acid derived CDs (CCDs). HCDs and SCDs possess optimal photostability, hypotoxicity and biocompatibility in zebrafish, indicating that HCDs and SCDs possess the capacity of being used as fluorescence probes for in vivo biological imaging. The long-time observation for fluorescence alternation of CDs in zebrafish and the quenching assay of CDs by ATP, NADH and Fe3+ ions demonstrated that the decaying process of CDs in vivo might be induced by the synergistic effect of the metabolism process. All results indicated that large batches and high QYs of CDs can be acquired by employing natural and nontoxic hair and skin as precursors. To our knowledge, this is the first time to report SCDs, in vivo comparative studies of HCDs, SCDs and CCDs as bioprobes, and explore their mechanism of photostability in zebrafish.

  5. CdS-sensitized TiO2 nanocorals: hydrothermal synthesis, characterization, application.

    PubMed

    Mali, S S; Desai, S K; Dalavi, D S; Betty, C A; Bhosale, P N; Patil, P S

    2011-10-01

    Cadmium sulfide (CdS) nanoparticle-sensitized titanium oxide nanocorals (TNC) were synthesized using a two-step deposition process. The TiO(2) nanocorals were grown on the conducting glass substrates (FTO) using A hydrothermal process and CdS nanoparticles were loaded on TNC using successive ionic layer adsorption and reaction (SILAR) method. The TiO(2), CdS and TiO(2)-CdS samples were characterized by optical absorption, X-ray diffraction (XRD), FT-Raman, FT-IR, scanning electron microscopy (SEM) and contact angle. Further, their photoelectrochemical (PEC) performance was tested in NaOH, Na(2)S-NaOH-S and Na(2)S electrolytes, respectively. When CdS nanoparticles are coated on TNCs, the optical absorption is found to be enhanced and band edge is red-shifted towards visible region. The TiO(2)-CdS sample exhibits improved photoelectrochemical (PEC) performance with maximum short circuit current of (J(sc)) 1.04 mA cm(-2). After applying these TiO(2)-CdS electrodes in photovoltaic cells, the photocurrent was found to be enhanced by 2.7 and 32.5 times, as compared with those of bare CdS and TiO(2) nanocorals films electrodes respectively. Also, the power conversion efficiency of TiO(2)-CdS electrodes is 0.72%, which is enhanced by about 16 and 29 times for TiO(2), CdS samples. This journal is © The Royal Society of Chemistry and Owner Societies 2011

  6. Label-free fluorimetric detection of CEA using carbon dots derived from tomato juice.

    PubMed

    Miao, Hong; Wang, Lan; Zhuo, Yan; Zhou, Zinan; Yang, Xiaoming

    2016-12-15

    A facile-green strategy to synthesize carbon dots (CDs) with a quantum yield (QY) of nearly 13.9% has been built up, while tomato juice served as the carbon source. Interestingly, not only the precursor of CDs and the whole synthesis procedure were environmental-friendly, but this type of CDs also exhibited multiple advantages including high fluorescent QY, excellent photostability, non-toxicity and satisfactory stability. Significantly, a label-free sensitive assay for detecting carcinoembryonic antigen (CEA) in a continuous and recyclable way has been proposed on the basis of adsorption and desorption of aptamers by the surface of CDs through a competitive mechanism. To be specific, the richness of carboxyl groups of the CDs enabled strong adsorption of ssDNA to the surface of CDs through π-π stacking interactions, resulting in the effective fluorescence quenching by forming CDs-aptamer complexes. The stronger binding affinity between CEA and CEA-aptamer than the π-π stacking interactions has been taken advantage to achieve immediate recovery of the fluorescence of CDs once CEA was introduced. Thereby, quantitative evaluation of CEA concentration in a broad range from 1ngmL(-1) to 0.5ngmL(-1) with the detection limit of 0.3ngmL(-1) was realized in this way. This strategy can be applied in a recyclable way, broadening the sensing application of CDs with biocompatibility. Besides, the CDs were used for cell imaging, potentiating them towards diverse purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Growth and characterization of CdS buffer layers by CBD and MOCVD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrone, A.A.; Huang, C.; Li, S.S.

    1999-03-01

    Thin film CdS has been widely used in thin-film photovoltaic devices. The most efficient Cu(In,&hthinsp;Ga)Se{sub 2} (CIGS) solar cells reported to date utilized a thin CdS buffer layer prepared by a reactive solution growth technique known as chemical bath deposition (CBD). Considerable effort has been directed to better understand the role and find a replacement for the CBD CdS process in CIGS-based solar cells. We reported a low temperature ({approximately}150&hthinsp;{degree}C) Metalorganic Chemical Vapor Deposition (MOCVD) CdS thin film buffer layer process for CIGS absorbers. Many prior studies have reported that CBD CdS contains a mixture of crystal structures. Recent investigationsmore » of CBD CdS thin films by ellipsometry suggested a multilayer structure. In this study we compare CdS thin films prepared by CBD and MOCVD and the effects of annealing. TED and XRD are used to characterize the crystal structure, the film microstructure is studied by HRTEM, and the optical properties are studied by Raman and spectrophotometry. All of these characterization techniques reveal superior crystalline film quality for CdS films grown by MOCVD compared to those grown by CBD. Dual Beam Optical Modulation (DBOM) studies showed that the MOCVD and CBD CdS buffer layer processes have nearly the same effect on CIGS absorbers when combined with a cadmium partial electrolyte aqueous dip. {copyright} {ital 1999 American Institute of Physics.}« less

  8. High Performance Photoluminescent Carbon Dots for In Vitro and In Vivo Bioimaging: Effect of Nitrogen Doping Ratios.

    PubMed

    Wang, Junqing; Zhang, Pengfei; Huang, Chao; Liu, Gang; Leung, Ken Cham-Fai; Wáng, Yì Xiáng J

    2015-07-28

    Photoluminescent carbon dots (CDs) have received ever-increasing attention in the application of optical bioimaging because of their low toxicity, tunable fluorescent properties, and ultracompact size. We report for the first time on enhanced photoluminescence (PL) performance influenced by structure effects among the various types of nitrogen doped (N-doped) PL CDs. These CDs were facilely synthesized from condensation carbonization of linear polyethylenic amine (PEA) analogues and citric acid (CA) of different ratios. Detailed structural and property studies demonstrated that either the structures or the molar ratio of PEAs altered the PL properties of the CDs. The content of conjugated π-domains with C═N in the carbon backbone was correlated with their PL Quantum Yield (QY) (up to 69%). The hybridization between the surface/molecule state and the carbon backbone synergistically affected the chemical/physical properties. Also, long-chain polyethylenic amine (PEA) molecule-doped CDs exhibit increasing photostability, but at the expense of PL efficiency, proving that the PL emission of high QY CDs arise not only from the sp(2)/sp(3) carbon core and surface passivation of CDs, but also from the molecular fluorophores integrated in the CDs. In vitro and in vivo bioimaging of these N-doped CDs showed strong photoluminescence signals. Good biocompatibility demonstrates their potential feasibility for bioimaging applications. In addition, the overall size profile of the as-prepared CDs is comparable to the average size of capillary pores in normal living tissues (∼5 nm). Our study provides valuable insights into the effects of the PEA doping ratios on photoluminescence efficiency, biocompatibility, cellular uptake, and optical bioimaging of CDs.

  9. Chemically Deposited CdS Buffer/Kesterite Cu2ZnSnS4 Solar Cells: Relationship between CdS Thickness and Device Performance.

    PubMed

    Hong, Chang Woo; Shin, Seung Wook; Suryawanshi, Mahesh P; Gang, Myeng Gil; Heo, Jaeyeong; Kim, Jin Hyeok

    2017-10-25

    Earth-abundant, copper-zinc-tin-sulfide (CZTS), kesterite, is an attractive absorber material for thin-film solar cells (TFSCs). However, the open-circuit voltage deficit (V oc -deficit) resulting from a high recombination rate at the buffer/absorber interface is one of the major challenges that must be overcome to improve the performance of kesterite-based TFSCs. In this paper, we demonstrate the relationship between device parameters and performances for chemically deposited CdS buffer/CZTS-based heterojunction TFSCs as a function of buffer layer thickness, which could change the CdS/CZTS interface conditions such as conduction band or valence band offsets, to gain deeper insight and understanding about the V oc -deficit behavior from a high recombination rate at the CdS buffer/kesterite interface. Experimental results show that device parameters and performances are strongly dependent on the CdS buffer thickness. We postulate two meaningful consequences: (i) Device parameters were improved up to a CdS buffer thickness of 70 nm, whereas they deteriorated at a thicker CdS buffer layer. The V oc -deficit in the solar cells improved up to a CdS buffer thickness of 92 nm and then deteriorated at a thicker CdS buffer layer. (ii) The minimum values of the device parameters were obtained at 70 nm CdS thickness in the CZTS TFSCs. Finally, the highest conversion efficiency of 8.77% (V oc : 494 mV, J sc : 34.54 mA/cm 2 , and FF: 51%) is obtained by applying a 70 nm thick CdS buffer to the Cu 2 ZnSn(S,Se) 4 absorber layer.

  10. Synthesis of CdS nanorods in soft template under gamma-irradiation.

    PubMed

    Zhao, Bing; Wang, Yanli; Zhang, Haijiao; Jiao, Zheng; Wang, Haobo; Ding, Guoji; Wu, Minghong

    2009-02-01

    CdS nano material which has a band gap of 2.42 eV at room temperature is a typical II-VII semiconductor having many commercial or potential applications, e.g., light-emitting diodes, solar cell and optoelectronic devices. In this paper, we use a new strategy to synthesize CdS nanorods. CdS nanorods were prepared in soft template under gamma-irradiation though the reaction of cadmium sulphide and thiacetamide (TAA). The formation process and characters of CdS nanorods was investigated in detail by transmission electron microscopy (TEM), electron diffraction (ED) pattern, X-ray powder diffraction (XRD), ultraviolet spectrophotometer (UV) and photoluminescence spectrophotometer (PL). In the experiment we proposed that the irradiation of gamma-ray accelerated the formation of S(2-) under acidic condition (pH = 3) and vinyl acetate (VAc) monomer formed pre-organized nano polymer tubules which were used as both templates and nanoreacters for the growth of CdS nanorods. In this process, we have obtained the CdS polycrystal nanorods with PVAc nano tubules and CdS single-crystal nanorods. The result of X-ray powder diffraction confirms that the crystal type of CdS nanorods is cubic F-43 m (216). The results from transmission electron microscopy and electron diffraction show that the concentrations of reactants and the dose rate of gamma-ray are key to produce appropriate CdS nanorods. Relatively low concentrations (Cd2+: 0.008-0.02 mol/L, Cd2+ : S(2-) = 1 : 2) of reactants and long time (1-2 d) of irradiation in low dose rate (6-14 Gy/min) are propitious to form CdS single-crystal nanorods with small diameter (less than 100 nm) and well length (2-5 microm). UV and PL characterizations show the sample have well optical properties.

  11. Nitrogen-doped carbon dots originating from unripe peach for fluorescent bioimaging and electrocatalytic oxygen reduction reaction.

    PubMed

    Atchudan, Raji; Edison, Thomas Nesakumar Jebakumar Immanuel; Lee, Yong Rok

    2016-11-15

    This paper reports the robust hydrothermal synthesis of nitrogen doped carbon dots (N-CDs) using the unripe fruit of Prunus persica (peach) as the carbon precursor and aqueous ammonia as the nitrogen source. The optical properties of synthesized N-CDs were characterized by ultraviolet visible (UV-Vis) and fluorescence spectroscopy techniques. The synthesized N-CDs were emitted blue light when excitated with a portable UV lamp. The materials with the optical properties were characterized further by high resolution transmission electron microscope (HRTEM), X-ray diffraction (XRD), Raman, Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopy (XPS). The mean size of the N-CDs was approximately 8nm, as calculated from the HRTEM image. The d-spacing of N-CDs, calculated using Bragg law, was approximately 0.21nm, which was consistent with the interlayer distance calculated from the HRTEM image. FT-IR spectroscopy and XPS revealed the presence of the phytoconstituents functionalities of peach fruit over the N-CDs surface and a high level of nitrogen doping on carbon dots (CDs) was confirmed by XPS studies. These results suggest that the unripe fruit extract of peach is an ideal candidate for the preparation of N-CDs. The resulting N-CDs showed excellent optical properties in water. The synthesized N-CDs exhibited a high fluorescence quantum yield and low cytotoxicity, and can be used as fluorescence imaging probes. In addition, the N-CDs were catalytically activite towards the oxygen reduction reaction (ORR). The N-CDs exhibited good catalytic activity in an alkaline medium (0.1M KOH) with a remarkable ORR of approximately 0.72V vs reversible hydrogen electrode (RHE), and O2 reduction follows mainly a 2 electron pathway by being reduced to hydrogen peroxide. The 2-electron reduction pathway is used in industry for H2O2 production. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Harmful impact on presynaptic glutamate and GABA transport by carbon dots synthesized from sulfur-containing carbohydrate precursor.

    PubMed

    Borisova, Tatiana; Dekaliuk, Mariia; Pozdnyakova, Natalia; Pastukhov, Artem; Dudarenko, Marina; Borysov, Arsenii; Vari, Sandor G; Demchenko, Alexander P

    2017-07-01

    Carbon nanoparticles that may be potent air pollutants with adverse effects on human health often contain heteroatoms including sulfur. In order to study in detail their effects on different physiological and biochemical processes, artificially produced carbon dots (CDs) with well-controlled composition that allows fluorescence detection may be of great use. Having been prepared from different types of organic precursors, CDs expose different atoms at their surface suggesting a broad variation of functional groups. Recently, we demonstrated neurotoxic properties of CDs synthesized from the amino acid β-alanine, and it is of importance to analyze whether CDs obtained from different precursors and particularly those exposing sulfur atoms induce similar neurotoxic effects. This study focused on synthesis of CDs from the sulfur-containing precursor thiourea-CDs (TU-CDs) with a size less than 10 nm, their characterization, and neuroactivity assessment. Neuroactive properties of TU-CDs were analyzed based on their effects on the key characteristics of glutamatergic and γ-aminobutyric acid (GABA) neurotransmission in isolated rat brain nerve terminals. It was observed that TU-CDs (0.5-1.0 mg/ml) attenuated the initial velocity of Na + -dependent transporter-mediated uptake and accumulation of L-[ 14 C]glutamate and [ 3 H]GABA by nerve terminals in a dose-dependent manner and increased the ambient level of the neurotransmitters. Starting from the concentration of 0.2 mg/ml, TU-CDs evoked a gradual dose-dependent depolarization of the plasma membrane of nerve terminals measured with the cationic potentiometric dye rhodamine 6G. Within the concentration range of 0.1-0.5 mg/ml, TU-CDs caused an "unphysiological" step-like increase in fluorescence intensity of the рН-sensitive fluorescent dye acridine orange accumulated by synaptic vesicles. Therefore, despite different surface properties and fluorescent features of CDs prepared from different starting materials (thiourea and β-alanine), their principal neurotoxic effects are analogous but displayed at a different level of efficiency. Sulfur-containing TU-CDs exhibit lower effects (by ~30%) on glutamate and GABA transport in the nerve terminals in comparison with sulfur-free β-alanine CDs. Our results suggest considering that an uncontrolled presence of carbon-containing particulate matter in the human environment may pose a toxicity risk for the central nervous system.

  13. Phase- and shape-controlled hydrothermal synthesis of CdS nanoparticles, and oriented attachment growth of its hierarchical architectures

    NASA Astrophysics Data System (ADS)

    Cao, Yali; Hu, Pengfei; Jia, Dianzeng

    2013-01-01

    Hydrothermal strategies were successfully used to control the phases and morphologies of CdS nanocrystals. In the absence of an external direction-controlling process, the hexagonal and cubic phase well-defined leaf- and flower-like CdS nanocrystals were controlled obtained via adjusting the reaction duration or the concentration of surfactant. Oriented attachment growth modes were suggested for the formation of CdS superstructures, which was clarified through the tracing of temporal evolution of CdS nanoparticles. The CdS superstructures were structured by primary building nanoparticles, and held excellent visible emission with a peak in the green regions. This strategy is very helpful for studying the phase and morphology controlled fabrication of sulfides nanocrystals.

  14. Biomimetic synthesis of needle-like fluorescent calcium phosphate/carbon dot hybrid composites for cell labeling and copper ion detection.

    PubMed

    Guo, Shanshan; Lu, Shousi; Xu, Pingxiang; Ma, Yi; Zhao, Liang; Zhao, Yuming; Gu, Wei; Xue, Ming

    2016-05-04

    Herein, we report a biomimetic method to synthesize needle-like calcium phosphate (CaP) with dimensions of ∼130 nm length and ∼30 nm width using carbon dots (CDs) and sodium carboxymethylcellulose as dual templates. In addition to acting as the template, the CDs enable the CaP/CDs hybrid composites to emit blue fluorescence under UV excitation. Moreover, the prepared CaP/CDs exhibited a negligible cytotoxicity towards HeLa cells. The potential of these CaP/CDs as a fluorescent probe for cell labeling was tested. In addition, it was demonstrated that the CaP/CDs were capable of selective detection of copper ions in drinking water.

  15. Biosynthesis of CdS nanoparticles in banana peel extract.

    PubMed

    Zhou, Guang Ju; Li, Shuo Hao; Zhang, Yu Cang; Fu, Yun Zhi

    2014-06-01

    Cadmium sulfide (CdS) nanoparticles (NPs) were synthesized by using banana peel extract as a convenient, non-toxic, eco-friendly 'green' capping agent. Cadmium nitrate and sodium sulfide are main reagents. A variety of CdS NPs are prepared through changing reaction conditions (banana extracts, the amount of banana peel extract, solution pH, concentration and reactive temperature). The prepared CdS colloid displays strong fluorescence spectrum. X-ray diffraction analysis demonstrates the successful formation of CdS NPs. Fourier transform infra-red (FTIR) spectrogram indicates the involvement of carboxyl, amine and hydroxyl groups in the formation of CdS NPs. Transmission electron microscope (TEM) result reveals that the average size of the NPs is around 1.48 nm.

  16. Unique organogel formation with macroporous materials constructed by the freeze-drying of aqueous cyclodextrin solutions.

    PubMed

    Marui, Yasuhiro; Kikuzawa, Akira; Kida, Toshiyuki; Akashi, Mitsuru

    2010-07-06

    Macroporous cyclodextrin materials (MP-alpha-, beta-, and gamma-CDs) were easily fabricated by the freeze-drying of aqueous solutions of alpha-, beta-, and gamma-CDs. These MP-CDs showed the absorption ability toward various organic solvents and oils to give organogels at ambient temperature. The morphological changes of the MP-CD microstructures were observed through the absorption of organic solvents. In particular, the absorption of polar organic solvents with hydrogen-bond forming ability, including 1,4-dioxane and ethanol, by the MP-CDs caused remarkable morphological changes in the microstructures. The absorption of these polar solvents by MP-alpha- and gamma-CDs resulted in the formation of channel-type assemblies of alpha- and gamma-CDs, respectively.

  17. Mn(II)-coordinated Fluorescent Carbon Dots: Preparation and Discrimination of Organic Solvents

    NASA Astrophysics Data System (ADS)

    Wang, Yuru; Wang, Tianren; Chen, Xi; Xu, Yang; Li, Huanrong

    2018-04-01

    Herein, we prepared a Mn(II)-coordinated carbon dots (CDs) with fluorescence and MRI (magnetic resonance imaging) bimodal properties by a one-pot solvothermal method and separated via silica column chromatography. The quantum yield of the CDs increased greatly from 2.27% to 6.75% with increase of Mn(II) doping, meanwhile the CDs exhibited a higher MR activity (7.28 mM-1s-1) than that of commercial Gd-DTPA (4.63 mM-1s-1). In addition, white light emitting CDs were obtained by mixing the different types of CDs. Notably, these CDs exhibited different fluorescence emissions in different organic solvents and could be used to discriminate organic solvents based on the polarity and protonation of the solvents.

  18. Minimum entropy principle-based solar cell operation without a pn-junction and a thin CdS layer to extract the holes from the emitter

    NASA Astrophysics Data System (ADS)

    Böer, Karl W.

    2016-10-01

    The solar cell does not use a pn-junction to separate electrons from holes, but uses an undoped CdS layer that is p-type inverted when attached to a p-type collector and collects the holes while rejecting the backflow of electrons and thereby prevents junction leakage. The operation of the solar cell is determined by the minimum entropy principle of the cell and its external circuit that determines the electrochemical potential, i.e., the Fermi-level of the base electrode to the operating (maximum power point) voltage. It leaves the Fermi level of the metal electrode of the CdS unchanged, since CdS does not participate in the photo-emf. All photoelectric actions are generated by the holes excited from the light that causes the shift of the quasi-Fermi levels in the generator and supports the diffusion current in operating conditions. It is responsible for the measured solar maximum power current. The open circuit voltage (Voc) can approach its theoretical limit of the band gap of the collector at 0 K and the cell increases the efficiency at AM1 to 21% for a thin-film CdS/CdTe that is given as an example here. However, a series resistance of the CdS forces a limitation of its thickness to preferably below 200 Å to avoid unnecessary reduction in efficiency or Voc. The operation of the CdS solar cell does not involve heated carriers. It is initiated by the field at the CdS/CdTe interface that exceeds 20 kV/cm that is sufficient to cause extraction of holes by the CdS that is inverted to become p-type. Here a strong doubly charged intrinsic donor can cause a negative differential conductivity that switches-on a high-field domain that is stabilized by the minimum entropy principle and permits an efficient transport of the holes from the CdTe to the base electrode. Experimental results of the band model of CdS/CdTe solar cells are given and show that the conduction bands are connected in the dark, where the electron current must be continuous, and the valence bands are connected with light where the hole currents are dominant and must be continuous through the junction. The major shifts of the bands in operating conditions are self-adjusting by a change in the junction dipole momentum.

  19. Impact of the Cornea Donor Study (CDS) on Acceptance of Corneas from Older Donors

    PubMed Central

    Sugar, Alan; Montoya, Monty M.; Beck, Roy; Cowden, John W.; Dontchev, Mariya; Gal, Robin L.; Kollman, Craig; Malling, Jackie; Mannis, Mark J.; Tennant, Bradley

    2014-01-01

    Purpose Evaluate retrospectively whether findings from the Cornea Donor Study (CDS) led to changes in the transplantation of corneas from older donors. Methods United States eye banks provided complete data on donor age and placement (domestic or international) for 86,273 corneas from 1998 to 2009. The data were analyzed by 3 time periods: preceding CDS (1998–1999), during CDS (2000–2007) and after publication of CDS 5 year results (2008–2009), and separately for corneas placed within vs. outside the United States. Results For corneal tissues transplanted in the United States, the percentage of donors ≥66 years old increased from 19% before CDS to 21% during CDS and 25% after CDS (p<0.001). Corresponding median (25th-75th percentile) donor ages were 53 (39–63), 54 (41–64) and 57 (46–66), respectively (p<0.001). The opposite trend was observed for corneas distributed outside the United States with the percentage of donors ≥66 years old decreasing from 56% to 42% to 34%, respectively. Donor age trends over time varied by eye bank. Conclusions There was a modest overall increase in the donor age of corneas transplanted in the United States from 1998 to 2009, but the retrospective nature of the study limits our ability to attribute this change to the CDS. The modest increases in the donor age of corneas transplanted is a positive finding, but wider acceptance of older corneal donor tissue should be encouraged based on the five-year evidence generated by the CDS. PMID:22262218

  20. Biological and catalytic applications of green synthesized fluorescent N-doped carbon dots using Hylocereus undatus.

    PubMed

    Arul, Velusamy; Edison, Thomas Nesakumar Jebakumar Immanuel; Lee, Yong Rok; Sethuraman, Mathur Gopalakrishnan

    2017-03-01

    In this work, a simple hydrothermal route for the synthesis of fluorescent nitrogen doped carbon dots (N-CDs) is reported. The Hylocereus undatus (H. undatus) extract and aqueous ammonia are used as carbon and nitrogen source, respectively. The optical properties of synthesized N-CDs are analyzed using UV-Visible (UV-Vis) and fluorescence spectroscopy. The surface morphology, elemental composition, crystallinity and functional groups present in the N-CDs are examined using high resolution transmission electron microscopy (HR-TEM) with energy dispersive spectroscopy (EDS), selected area electron diffraction (SAED), X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy, respectively. The synthesized N-CDs emit strong blue fluorescence at 400nm under the excitation of 320nm. Further, the excitation dependent emission properties are also observed from the fluorescence of synthesized N-CDs. The HR-TEM results reveal that synthesized N-CDs are in spherical shape with average diameter of 2.5nm. The XRD pattern exhibits, the graphitic nature of synthesized N-CDs. The doping of nitrogen is confirmed from the EDS and FT-IR studies. The cytotoxicity and biocompatibility of N-CDs are evaluated through MTT assay on L-929 (Lymphoblastoid-929) and MCF-7 (Michigan Cancer Foundation-7) cells. The results indicate that the fluorescent N-CDs show less cytotoxicity and good biocompatibility on both L-929 and MCF-7 cells. Moreover, the N-CDs show excellent catalytic activity towards the reduction of methylene blue by sodium borohydride. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Structural Dynamics of Carbon Dots in Water and N, N-Dimethylformamide Probed by All-Atom Molecular Dynamics Simulations.

    PubMed

    Paloncýová, Markéta; Langer, Michal; Otyepka, Michal

    2018-04-10

    Carbon dots (CDs), one of the youngest members of the carbon nanostructure family, are now widely experimentally studied for their tunable fluorescence properties, bleaching resistance, and biocompatibility. Their interaction with biomolecular systems has also been explored experimentally. However, many atomistic details still remain unresolved. Molecular dynamics (MD) simulations enabling atomistic and femtosecond resolutions simultaneously are a well-established tool of computational chemistry which can provide useful insights into investigated systems. Here we present a full procedure for performing MD simulations of CDs. We developed a builder for generating CDs of a desired size and with various oxygen-containing surface functional groups. Further, we analyzed the behavior of various CDs differing in size, surface functional groups, and degrees of functionalization by MD simulations. These simulations showed that surface functionalized CDs are stable in a water environment through the formation of an extensive hydrogen bonding network. We also analyzed the internal dynamics of individual layers of CDs and evaluated the role of surface functional groups on CD stability. We observed that carboxyl groups interconnected the neighboring layers and decreased the rate of internal rotations. Further, we monitored changes in the CD shape caused by an excess of charged carboxyl groups or carbonyl groups. In addition to simulations in water, we analyzed the behavior of CDs in the organic solvent DMF, which decreased the stability of pure CDs but increased the level of interlayer hydrogen bonding. We believe that the developed protocol, builder, and parameters will facilitate future studies addressing various aspects of structural features of CDs and nanocomposites containing CDs.

  2. Simple and green synthesis of protein-conjugated CdS nanoparticles and spectroscopic study on the interaction between CdS and zein

    NASA Astrophysics Data System (ADS)

    Qin, Dezhi; Zhang, Li; Du, Xian; Wang, Yabo; Zhang, Qiuxia

    2016-09-01

    The present study demonstrates the role of zein molecules in synthesizing CdS nanoassemblies through protein-directed, green synthetic approach. Zein molecules can as capping ligand and stabilizing agent to regulate the nucleation and growth of CdS nanocrystals, and the obtained products are organic-inorganic nanocomposites. The analysis of surface charge and conductivity indicates that strong electrostatic force restricts mobility of ions, which creates a local supersaturation surrounding the binding sites of zein and reduces the activated energy of nucleation. The interaction between Cd2+/CdS and zein molecules was systematically investigated through spectroscopy techniques. Fourier transform infrared (FT-IR) spectra were used to envisage the binding of the functional groups of zein with the surface of CdS nanoparticles. Ultraviolet visible (UV-Vis) and photoluminescence (PL) spectra results show that Cd2+/CdS might interact with the aromatic amino acids of protein molecules and change its chemical microenvironment. The quantum-confined effect of nanocrystals is confirmed by optical absorption spectrum due to the small size (3-5 nm) of CdS particles. The data of circular dichroism (CD) spectra indicate that the formation of CdS nanocrystals could lead to the conformational change of zein molecules. Moreover, the possible mechanism of CdS nanocrystals growth in zein solution was also discussed. The weak interactions such as Van der Waals, hydrophobic forces and hydrogen bonds in zein molecules should play a crucial factor in the self-assembly of small nanoparticles.

  3. Facile and eco-friendly synthesis of green fluorescent carbon nanodots for applications in bioimaging, patterning and staining.

    PubMed

    Shi, Lihong; Li, Yanyan; Li, Xiaofeng; Wen, Xiangping; Zhang, Guomei; Yang, Jun; Dong, Chuan; Shuang, Shaomin

    2015-04-28

    We report a facile and eco-friendly strategy for the fabrication of green fluorescent carbon nanodots (CDs), and demonstrate their applications for bio-imaging, patterning, and staining. A one-pot hydrothermal method using various plant petals yields bright green-emitting CDs, providing an easy way for the production of green fluorescent CDs without the need for a tedious synthetic methodology or the use of toxic/expensive solvents and starting materials. The as-prepared CDs show small size distribution and excellent dispersibility. Their strong green fluorescence is observed when the excitation wavelength is between 430 nm and 490 nm. Moreover, they exhibit high tolerance to various external conditions, such as pH values, external cations, and continuous excitation. Due to minimum toxicity as well as good photoluminescence properties, these CDs can be applied to in vitro and in vivo imaging, patterning, and staining. According to confocal fluorescence imaging of human uterine cervical squamous cell carcinoma cells, CDs penetrate into the cell and enter the cytoplasm and the nucleus. More strikingly, carp is directly fed with CDs for in vivo imaging and shows bright green fluorescence at an excitation wavelength of 470 nm. In addition, the obtained CDs are used as fluorescent inks for drawing luminescence patterns. Finally, we also apply the CDs as a fluorescent dye. Interestingly, the absorbent filter paper with staining emits dramatic fluorescence under 470 nm excitation.

  4. Rapid solid-phase microwave synthesis of highly photoluminescent nitrogen-doped carbon dots for Fe3+ detection and cellular bioimaging

    NASA Astrophysics Data System (ADS)

    He, Guili; Xu, Minghan; Shu, Mengjun; Li, Xiaolin; Yang, Zhi; Zhang, Liling; Su, Yanjie; Hu, Nantao; Zhang, Yafei

    2016-09-01

    Recently, carbon dots (CDs) have been playing an increasingly important role in industrial production and biomedical field because of their excellent properties. As such, finding an efficient method to quickly synthesize a large scale of relatively high purity CDs is of great interest. Herein, a facile and novel microwave method has been applied to prepare nitrogen doped CDs (N-doped CDs) within 8 min using L-glutamic acid as the sole reaction precursor in the solid phase condition. The as-prepared N-doped CDs with an average size of 1.64 nm are well dispersed in aqueous solution. The photoluminescence of N-doped CDs is pH-sensitive and excitation-dependent. The N-doped CDs show a strong blue fluorescence with relatively high fluorescent quantum yield of 41.2%, which remains stable even under high ionic strength. Since the surface is rich in oxygen-containing functional groups, N-doped CDs can be applied to selectively detect Fe3+ with the limit of detection of 10-5 M. In addition, they are also used for cellular bioimaging because of their high fluorescent intensity and nearly zero cytotoxicity. The solid-phase microwave method seems to be an effective strategy to rapidly obtain high quality N-doped CDs and expands their applications in ion detection and cellular bioimaging.

  5. Facile green synthesis of fluorescent N-doped carbon dots from Actinidia deliciosa and their catalytic activity and cytotoxicity applications

    NASA Astrophysics Data System (ADS)

    Arul, Velusamy; Sethuraman, Mathur Gopalakrishnan

    2018-04-01

    Green synthesis of fluorescent nitrogen doped carbon dots (N-CDs) using Actinidia deliciosa (A. deliciosa) fruit extract as a carbon precursor and aqueous ammonia as a nitrogen dopant is reported here. The synthesized N-CDs were characterized by high resolution transmission electron microscopy (HR-TEM), energy dispersive spectroscopy (EDS), selected area electron diffraction (SAED), UV-Visible spectroscopy (UV-Vis), fluorescence spectroscopy, Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). The average size of the N-CDs was approximately 3.59 nm and the calculated inter layer distance was found to be 0.21 nm. Raman spectroscopy and SAED pattern revealed the graphitic nature of the synthesized N-CDs. The N-CDs were found to emit intense blue color at 405 nm under the excitation of 315 nm. The doping of nitrogen over the surface of the N-CDs was confirmed by EDS, FT-IR and XPS studies. The synthesized N-CDs were found to exhibit excellent catalytic activity in the reduction of Rhodamine-B using sodium borohydrate. The MTT assay was used to evaluate the cytotoxicity and biocompatibility of N-CDs towards L-929 and MCF-7 cells. From the results obtained, it was found that the N-CDs exhibit low cytotoxicity and superior biocompatibility on both L-929 and MCF-7 cells.

  6. Development of CdS Nanostructures by Thermal Decomposition of Aminocaproic Acid-Mixed Cd-Thiourea Complex Precursor: Structural, Optical and Photocatalytic Characterization.

    PubMed

    Patel, Jayesh D; Mighri, Frej; Ajji, Abdellah; Chaudhuri, Tapas K

    2015-04-01

    The present work deals with two different CdS nanostructures produced via hydrothermal and solvothermal decompositions of aminocaproic acid (ACA)-mixed Cd-thiourea complex precursor at 175 °C. Both nanostructures were extensively characterized for their structural, morphological and optical properties. The powder X-ray diffraction characterization showed that the two CdS nanostructures present a wurtzite morphology. Scanning electron microscopy and energy-dispersive X-ray characterizations revealed that the hydrothermal decomposition produced well-shaped CdS flowers composed of six dendritic petals, and the solvothermal decomposition produced CdS microspheres with close stoichiometric chemical composition. The UV-vis absorption and photoluminescence spectra of CdS dendritic flowers and microsphere nanostructures showed that both nanostructures present a broad absorption between 200 and 700 nm and exhibit strong green emissions at 576 and 520 nm upon excitations at 290 nm and 260 nm, respectively. The transmission electron microscopy (TEM) and Brunauer-Emmett-Teller (BET) characterizations confirmed that CdS microspheres were mesoporous and were composed of small nanocrystals. A possible growth mechanism in the formation of the CdS nanostructures was proposed based on morphology evolution as a function of the reaction time. Furthermore, the as-synthesized CdS nanostructures were found to exhibit highly efficient photocatalytic activities for the degradation of methyl orange (MeO) and rhodamine B (RhB) dyes.

  7. The excitonic photoluminescence mechanism and lasing action in band-gap-tunable CdS(1-x)Se(x) nanostructures.

    PubMed

    Dai, Jun; Zhou, Pengxia; Lu, Junfeng; Zheng, Hongge; Guo, Jiyuan; Wang, Fang; Gu, Ning; Xu, Chunxiang

    2016-01-14

    Bandgap tunable semiconductor materials have wide application in integrated-optoelectronic and communication devices. The CdS1-xSex ternary semiconductor materials covering green-red bands have been reported previously, but their basic band-gap and optical properties crucial to the performance of the CdS1-xSex-based optoelectronic devices have not been deeply understood. In this paper, we theoretically simulated and discussed the feasibility of bandgap-tunable CdS1-xSex nanomaterials for designing wavelength tunable microlasers. Then we fabricated the CdS1-xSex nanobelts with their band gap ranging from 2.4 to 1.74 eV by adjusting the composition ratio x in the vapor-phase-transport growth process. The temperature-dependent photoluminescence and exciton-related optical constants of the CdS1-xSex nanobelts were carefully demonstrated. Finally, the wavelength-tunable Fabry-Perot lasing in CdS1-xSex nanobelts was obtained, and the Fabry-Perot lasing mechanism was numerically simulated by the FDTD method. The systematic results on the mechanism of the tunable band gap, exciton properties and lasing of the CdS1-xSex nanostructure help us deeply understand the intrinsic optical properties of this material, and will build a strong foundation for future application of green-red wavelength-tunable CdS1-xSex microlasers.

  8. Carbon dots as fluorescent probes for "off-on" detection of Cu2+ and L-cysteine in aqueous solution.

    PubMed

    Zong, Jie; Yang, Xiaoling; Trinchi, Adrian; Hardin, Simon; Cole, Ivan; Zhu, Yihua; Li, Chunzhong; Muster, Tim; Wei, Gang

    2014-01-15

    Copper ion (Cu(2+)) and L-cysteine (L-Cys) detection is critically important since an abnormal level of Cu(2+) or L-Cys is an indicator for many diseases. In this paper, we demonstrate an "off-on" approach for highly sensitive and selective detection of Cu(2+) and L-Cys using carbon dots (CDs) as fluorescent probes. CDs were prepared by using mesoporous silica (MS) spheres as nanoreactors. The binding ability of CDs towards metal ions was examined by comparing the fluorescence intensities of CDs before and after the addition of the metal ions. The addition of Cu(2+) cations leads to their absorption on the surface of CDs and the significant fluorescence quench of CDs (turn-off). The resulting in CDs-Cu(2+) system was found to be sensitive to L-Cys. The addition of L-Cys not only serves to shelter the CDs effectively from being quenched, but also to reverse the quenching and restore the fluorescence (turn-on) due to its ability to remove Cu(2+) from the surface of CDs. This method is facile, rapid, low cost, and environment-friendly. A detection limit as low as 2.3×10(-8) M for Cu(2+) and 3.4×10(-10) M for L-Cys is obtained, which is promising for biological applications. © 2013 Elsevier B.V. All rights reserved.

  9. 75 FR 11589 - Order Extending Temporary Exemptions Under the Securities Exchange Act of 1934 in Connection with...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... make payments under a CDS contract is triggered by a default or other credit event as to such entity or... CDS clearing by ICE Trust. We recognize, however, that there could be legal uncertainty in the event..., and the access to clearing services by independent CDS exchanges or CDS trading platforms.\\15\\ \\15...

  10. Facile synthesis of S, N co-doped carbon dots and investigation of their photoluminescence properties.

    PubMed

    Zhang, Yue; He, Junhui

    2015-08-21

    A facile one-pot approach to prepare photoluminescent carbon dots (CDs) was developed through hydrothermal treatment of cysteine and citric acid. The obtained CDs show stable and bright blue emission with a quantum yield of 54% and an average lifetime of 11.61 ns. Moreover, the two-photon induced upconversion fluorescence of the CDs was observed and demonstrated. Interestingly, both down and up conversion fluorescence of the CDs show excitation-independent emission, which is quite different from most of the previously reported CDs. Ultrafast spectroscopy was also employed here to study the photoluminescence (PL) properties of the CDs. After characterization using various spectroscopic techniques, a unique PL mechanism for the as-prepared CDs' fluorescence was proposed accordingly. In addition, the influence of various metal ions on the CD fluorescence was examined and no quenching phenomena were observed. Meanwhile, gold nanoparticles (Au NPs) were found to be good quenchers of CD fluorescence and their quenching behavior was fitted to the Stern-Volmer equation. This provides new opportunities for fluorescence sensor designs and light energy conversion applications. Finally, the as-prepared CDs were inkjet-printed to form a desirable pattern, which is useful for fluorescent patterns, and anti-counterfeiting labeling.

  11. Fabrication of luminescent CdS nanoparticles on short-peptide-based hydrogel nanofibers: tuning of optoelectronic properties.

    PubMed

    Palui, Goutam; Nanda, Jayanta; Ray, Sudipta; Banerjee, Arindam

    2009-07-13

    The pH-induced self-assembly of three synthetic tripeptides in water medium is used to immobilize luminescent CdS nanoparticles. These peptides form a nanofibrillar network structure upon gelation in aqueous medium at basic pH values (pH 11.0-13.0), and the fabrication of CdS nanoparticles on the gel nanofiber confers the luminescent property to these gels. Atomic force microscopy, field-emission scanning electron microscopy, and high-resolution transmission electron microscopy clearly reveal the presence of CdS nanoparticles in a well-defined array on the gel nanofibers. This is a convenient way to make organic nanofiber-inorganic nanoparticle hybrid nanocomposite systems. The size of the CdS nanoparticles remains almost same before and after deposition on the gel nanofiber. Photoluminescence (PL) measurement of the CdS nanoparticles upon deposition on the gel nanofibers shows a significant blue shift in the emission spectrum of the nanoparticles, and there is a considerable change in the PL gap energy of the CdS nanoparticles after immobilization on different gel nanofibrils. This finding suggests that the optoelectronic properties of CdS nanoparticles can be tuned upon deposition on gel nanofibers without changing the size of the nanoparticles.

  12. Fluorescent chemosensor for pyridine based on N-doped carbon dots.

    PubMed

    Campos, B B; Abellán, C; Zougagh, M; Jimenez-Jimenez, J; Rodríguez-Castellón, E; Esteves da Silva, J C G; Ríos, A; Algarra, M

    2015-11-15

    Fluorescent carbon dots (CDs) and its nitrogen doped (N-CDs) nanoparticles have been synthesized from lactose as precursor using a bottom-up hydrothermal methodology. The synthesized nanoparticles have been characterized by elemental analysis, FTIR, Raman, TEM, DLS, XPS, and steady-state and life-time fluorescence. The synthesized carbon nanoparticles, CDs and N-CDs, have a size at about 7.7±2.4 and 50±15nm, respectively, and quantum yields of 8% (CDs) and 11% (N-CDs). These techniques demonstrated the effectiveness of the synthesis procedure and the functionalization of the CDs surface with amine and amide groups in the presence of NH3 in aqueous media. The effect of excitation wavelength and pH on the luminescent properties was studied. Under the optimal conditions, the nitrogen doped nanoparticles can be used as pyridine sensor in aqueous media because they show an enhancement of its fluorescence with a good linear relationship. The analytical method is simple, reproducible and very sensitive for pyridine determination. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Distribution of different surface modified carbon dots in pumpkin seedlings.

    PubMed

    Qian, Kun; Guo, Huiyuan; Chen, Guangcai; Ma, Chuanxin; Xing, Baoshan

    2018-05-22

    The distribution of surface modified carbon dots (CDs) in the pumpkin seedlings was studied by visualization techniques and their potential phytotoxicity was investigated at both the physiological and biochemical levels. The average size of carbon dots was approximately 4 nm. The fluorescent peaks of bared CDs, CD-PEI and CD-PAA were between 420 nm and 500 nm, indicating CDs could emit blue and green fluorescence. Fluorescent images showed that all three types of CDs could accumulate in the pumpkin roots and translocate to the shoots, although the distribution pattern of each CDs was obviously different. At the biochemical level, the elevated antioxidant enzymes in pumpkin roots suggest that all the CDs could potentially trigger the antioxidant defense systems in pumpkin seedlings. Additionally, such alteration was greater in the roots than in the shoots. Our study represents a new perspective on CD visualization in plant tissues and provide useful information for the potential toxicity of different types of CDs to terrestrial plants, which is of importance to agricultural application.

  14. Enhanced photo response of mesoporous nanostructured CdS thin film via electrospray aerosol deposition technique

    NASA Astrophysics Data System (ADS)

    Logu, T.; Soundarrajan, P.; Sankarasubramanian, K.; Sethuraman, K.

    2018-04-01

    In this work, a high crystalline and mesoporous nanostructured cadmium sulfide (CdS) thin film was successfully grown on the FTO substrates using facile Electrospray Aerosol Deposition (ESAD) technique. The structural, optical, morphological and electrical properties of CdS thin film have been systematically examined. CdS thin film exhibits the hexagonal wurtzite crystal structure with polycrystalline nature. The optical band gap energy of the prepared film was estimated from the Tauc plot and is 2.43 eV. The SEM and AFM images show that the well-interconnected CdS nanoparticles gives mesoporous like morphology. The fine aerosol generated from the ESAD process induces the alteration in the surface morphological structure of deposited CdS film that consequences in enhanced electrical and photo-physical properties. The photoconductivity of the sample has been studied which demonstrates significant photo current. The present study predicts that mesoporous nanostructured CdS thin film would be given a special interest for optoelectronic applications.

  15. Arrays of Ultrathin CdS Nanoflakes with High-Energy Surface for Efficient Gas Detection.

    PubMed

    Liu, Xiao-Hua; Yin, Peng-Fei; Kulinich, Sergei A; Zhou, Yu-Zhu; Mao, Jing; Ling, Tao; Du, Xi-Wen

    2017-01-11

    It is fascinating and challenging to endow conventional materials with unprecedented properties. For instance, cadmium sulfide (CdS) is an important semiconductor with excellent light response; however, its potential in gas-sensing was underestimated owing to relatively low chemical activity and poor electrical conductivity. Herein, we demonstrate that an ideal architecture, ultrathin nanoflake arrays (NFAs), can improve significantly gas-sensing properties of CdS material. The CdS NFAs are grown directly on the interdigitated electrode to expose large surface area. Their thickness is reduced below the double Debye length of CdS, permitting to achieve a full depletion of carriers. Particularly, the prepared CdS nanoflakes are enclosed with high-energy {0001} facets exposed, which provides more active sites for gas adsorption. Moreover, the NFAs exhibit the light-trapping effect, which further enhances their gas sensitivity. As a result, the as-prepared CdS NFAs demonstrate excellent gas-sensing and light-response properties, thus being capable of dual gas and light detection.

  16. Two Closely Related Genes of Arabidopsis Encode Plastidial Cytidinediphosphate Diacylglycerol Synthases Essential for Photoautotrophic Growth1[C

    PubMed Central

    Haselier, André; Akbari, Hana; Weth, Agnes; Baumgartner, Werner; Frentzen, Margrit

    2010-01-01

    Cytidinediphosphate diacylglycerol synthase (CDS) catalyzes the formation of cytidinediphosphate diacylglycerol, an essential precursor of anionic phosphoglycerolipids like phosphatidylglycerol or -inositol. In plant cells, CDS isozymes are located in plastids, mitochondria, and microsomes. Here, we show that these isozymes are encoded by five genes in Arabidopsis (Arabidopsis thaliana). Alternative translation initiation or alternative splicing of CDS2 and CDS4 transcripts can result in up to 10 isoforms. Most of the cDNAs encoding the various plant isoforms were functionally expressed in yeast and rescued the nonviable phenotype of the mutant strain lacking CDS activity. The closely related genes CDS4 and CDS5 were found to encode plastidial isozymes with similar catalytic properties. Inactivation of both genes was required to obtain Arabidopsis mutant lines with a visible phenotype, suggesting that the genes have redundant functions. Analysis of these Arabidopsis mutants provided further independent evidence for the importance of plastidial phosphatidylglycerol for structure and function of thylakoid membranes and, hence, for photoautotrophic growth. PMID:20442275

  17. CeO₂ Enhanced Ethanol Sensing Performance in a CdS Gas Sensor.

    PubMed

    Li, Meishan; Ren, Wei; Wu, Rong; Zhang, Min

    2017-07-05

    CdS nanowires (NWs) were fabricated through a facile low-temperature solvothermal method, following which CeO₂ nanoparticles were modified on the NWs. The ethanol sensing characteristics of pure CdS and decorated ones with different CeO₂ content were studied. It was found that the sensing performance of CdS was significantly improved after CeO₂ decoration. In particular, the 5 at% CeO₂/CdS composite exhibited a much higher response to 100 ppm ethanol (about 52), which was 2.6 times larger than that of pure CdS. A fast response and recovery time (less than 12 s and 3 s, respectively) were obtained as well as an excellent selectivity. These results make the CeO₂-decorated CdS NWs good candidates for ethanol sensing applications.

  18. Quick synthesis of 2-propanol derived fluorescent carbon dots for bioimaging applications

    NASA Astrophysics Data System (ADS)

    Angamuthu, Raja; Palanisamy, Priya; Vasudevan, Vasanthakumar; Nagarajan, Sedhu; Rajendran, Ramesh; Vairamuthu, Raj

    2018-04-01

    Herein, for the first time, we present a one-pot ingenious preparative method for fluorescent carbon dots from 2-propanol (2P-CDs) without external treatments. Structure, morphology, chemical composition and fluorescence properties of the 2P-CDs were examined. These results confirm that the as-synthesized 2P-CDs are amorphous, monodispersed, spherical and the average particle size is 2.5 ± 0.7 nm. Most importantly, excitation-dependent emission properties were observed, which suggest that these 2P-CDs may be used in multicolor bioimaging applications. When incubated with HeLa cells, the 2P-CDs exhibit low cytotoxicity, and positive biocompatibility. Confocal microscopy image shows the uptake of 2P-CDs by HeLa cells and the application of probable biomarker is demonstrated.

  19. Optical characterization of CdS nanorods capped with starch

    NASA Astrophysics Data System (ADS)

    Roy, J. S.; Pal Majumder, T.; Schick, C.

    2015-05-01

    Well crystalline uniform CdS nanorods were grown by changing the concentration of maize starch. The highly polymeric (branched) structure of starch enhances the growth of CdS nanorods. The average diameter of the nanorods is 20-25 nm while length is of 500-600 nm as verified from SEM and XRD observations. The optical band gaps of the CdS nanorods are varying from 2.66 eV to 2.52 eV depending on concentration of maize starch. The photoluminescence (PL) emission bands are shifted from 526 nm to 529 nm with concentration of maize starch. We have also observed the enhanced PL intensity in CdS nanorods capped with starch. The Fourier transform infrared (FTIR) spectroscopy shows the significant effect of starch on CdS nanorods.

  20. Wavelength tunable single nanowire lasers based on surface plasmon polariton enhanced Burstein-Moss effect.

    PubMed

    Liu, Xinfeng; Zhang, Qing; Yip, Jing Ngei; Xiong, Qihua; Sum, Tze Chien

    2013-01-01

    Wavelength tunable semiconductor nanowire (NW) lasers are promising for multifunctional applications ranging from optical communication to spectroscopy analysis. Here, we present a demonstration of utilizing the surface plasmon polariton (SPP) enhanced Burstein-Moss (BM) effect to tune the lasing wavelength of a single semiconductor NW. The photonic lasing mode of the CdS NW (with length ~10 μm and diameter ~220 nm) significantly blue shifts from 504 to 483 nm at room temperature when the NW is in close proximity to the Au film. Systematic steady state power dependent photoluminescence (PL) and time-resolved PL studies validate that the BM effect in the hybrid CdS NW devices is greatly enhanced as a consequence of the strong coupling between the SPP and CdS excitons. With decreasing dielectric layer thickness h from 100 to 5 nm, the enhancement of the BM effect becomes stronger, leading to a larger blue shift of the lasing wavelength. Measurements of enhanced exciton emission intensities and recombination rates in the presence of Au film further support the strong interaction between SPP and excitons, which is consistent with the simulation results.

  1. Child Development Services: Army Regulation 608-10 (Effective 15 October 1983).

    ERIC Educational Resources Information Center

    Department of the Army, Washington, DC.

    As of October 15, 1983, Army Regulation 608-10 has prescribed policies, procedures, and standards for establishing and operating Child Development Services (CDS), formerly Child Support Services, at Army installations. The regulation applies to all activities, contractors, individuals, and private organizations providing child care services for…

  2. Green Synthesis of Bifunctional Fluorescent Carbon Dots from Garlic for Cellular Imaging and Free Radical Scavenging.

    PubMed

    Zhao, Shaojing; Lan, Minhuan; Zhu, Xiaoyue; Xue, Hongtao; Ng, Tsz-Wai; Meng, Xiangmin; Lee, Chun-Sing; Wang, Pengfei; Zhang, Wenjun

    2015-08-12

    Nitrogen and sulfur codoped carbon dots (CDs) were prepared from garlic by a hydrothermal method. The as-prepared CDs possess good water dispersibility, strong blue fluorescence emission with a fluorescent quantum yield of 17.5%, and excellent photo and pH stabilities. It is also demonstrated that the fluorescence of CDs are resistant to the interference of metal ions, biomolecules, and high ionic strength environments. Combining with low cytotoxicity properties, CDs could be used as an excellent fluorescent probe for cellular multicolor imaging. Moreover, the CDs were also demonstrated to exhibit favorable radical scavenging activity.

  3. Synthesis and formation mechanistic investigation of nitrogen-doped carbon dots with high quantum yields and yellowish-green fluorescence

    NASA Astrophysics Data System (ADS)

    Hou, Juan; Wang, Wei; Zhou, Tianyu; Wang, Bo; Li, Huiyu; Ding, Lan

    2016-05-01

    Heteroatom doped carbon dots (CDs) have received increasing attention due to their unique properties and related applications. However, previously reported CDs generally show strong emission only in the blue-light region, thus restricting their further applications. And the fundamental investigation on the preparation process is always neglected. Herein, we have developed a simple and solvent-free synthetic strategy to fabricate nitrogen-doped CDs (N-CDs) from citric acid and dicyandiamide. The as-prepared N-CDs exhibited a uniform size distribution, strong yellowish-green fluorescence emission and a high quantum yield of 73.2%. The products obtained at different formation stages were detailedly characterized by transmission electron microscopy, X-ray diffraction spectrometer, X-ray photoelectron spectroscopy and UV absorbance spectroscopy. A possible formation mechanism has thus been proposed including dehydration, polymerization and carbonization. Furthermore, the N-CDs could serve as a facile and label-free probe for the detection of iron and fluorine ions with detection limits of 50 nmol L-1 and 75 nmol L-1, respectively.Heteroatom doped carbon dots (CDs) have received increasing attention due to their unique properties and related applications. However, previously reported CDs generally show strong emission only in the blue-light region, thus restricting their further applications. And the fundamental investigation on the preparation process is always neglected. Herein, we have developed a simple and solvent-free synthetic strategy to fabricate nitrogen-doped CDs (N-CDs) from citric acid and dicyandiamide. The as-prepared N-CDs exhibited a uniform size distribution, strong yellowish-green fluorescence emission and a high quantum yield of 73.2%. The products obtained at different formation stages were detailedly characterized by transmission electron microscopy, X-ray diffraction spectrometer, X-ray photoelectron spectroscopy and UV absorbance spectroscopy. A possible formation mechanism has thus been proposed including dehydration, polymerization and carbonization. Furthermore, the N-CDs could serve as a facile and label-free probe for the detection of iron and fluorine ions with detection limits of 50 nmol L-1 and 75 nmol L-1, respectively. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02701f

  4. A novel fluorescent retrograde neural tracer: cholera toxin B conjugated carbon dots

    NASA Astrophysics Data System (ADS)

    Zhou, Nan; Hao, Zeyu; Zhao, Xiaohuan; Maharjan, Suraj; Zhu, Shoujun; Song, Yubin; Yang, Bai; Lu, Laijin

    2015-09-01

    The retrograde neuroanatomical tracing method is a key technique to study the complex interconnections of the nervous system. Traditional tracers have several drawbacks, including time-consuming immunohistochemical or immunofluorescent staining procedures, rapid fluorescence quenching and low fluorescence intensity. Carbon dots (CDs) have been widely used as a fluorescent bio-probe due to their ultrasmall size, excellent optical properties, chemical stability, biocompatibility and low toxicity. Herein, we develop a novel fluorescent neural tracer: cholera toxin B-carbon dot conjugates (CTB-CDs). It can be taken up and retrogradely transported by neurons in the peripheral nervous system of rats. Our results show that CTB-CDs possess high photoluminescence intensity, good optical stability, a long shelf-life and non-toxicity. Tracing with CTB-CDs is a direct and more economical way of performing retrograde labelling experiments. Therefore, CTB-CDs are reliable fluorescent retrograde tracers.The retrograde neuroanatomical tracing method is a key technique to study the complex interconnections of the nervous system. Traditional tracers have several drawbacks, including time-consuming immunohistochemical or immunofluorescent staining procedures, rapid fluorescence quenching and low fluorescence intensity. Carbon dots (CDs) have been widely used as a fluorescent bio-probe due to their ultrasmall size, excellent optical properties, chemical stability, biocompatibility and low toxicity. Herein, we develop a novel fluorescent neural tracer: cholera toxin B-carbon dot conjugates (CTB-CDs). It can be taken up and retrogradely transported by neurons in the peripheral nervous system of rats. Our results show that CTB-CDs possess high photoluminescence intensity, good optical stability, a long shelf-life and non-toxicity. Tracing with CTB-CDs is a direct and more economical way of performing retrograde labelling experiments. Therefore, CTB-CDs are reliable fluorescent retrograde tracers. Electronic supplementary information (ESI) available: PL spectra of CTB; absorption spectra of dialysate; fluorescence signal and immunohistochemical staining of CTB-CDs in L4 DRG. See DOI: 10.1039/c5nr04361a

  5. Annealing effects on the chemical deposited CdS films and the electrical properties of CdS/CdTe solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Junfeng; Institute of Materials Science, Darmstadt University of Technology, Petersenstr. 23, 64287 Darmstadt; Liao, Cheng, E-mail: Cliao@pku.edu.cn

    2011-02-15

    Graphical abstract: From XPS core level spectras, compared with as-depositing CdS (sample A), the Fermi level is shifting closer to the conduction band after annealing treatment in the oxygen (sample B) while it is shifting closer to the valence band after annealing treatment in the argon-hydrogen (sample C). That might be the main reason of the different performance of the final devices. The open circuit voltage of the CdS/CdTe solar cell increases when the CBD CdS is annealed with oxygen, while the performance of the solar cell decreases when the CBD CdS is annealed with argon-hydrogen. Research highlights: {yields} Twomore » different methods (oxidation and reduction) were used to anneal CdS films for CdTe solar cells. {yields} Electrical properties were analyzed by XPS (Fermi levels of CdS films). {yields} Annealing treatment in oxidation atmosphere could shift Fermi level of CdS film to higher position and consequently improve the CdS/CdTe junction and performance of solar cells. -- Abstract: CdS layers grown by chemical bath deposition (CBD) are annealed in the oxygen and argon-hydrogen atmosphere respectively. It has been found that the open circuit voltage of the CdS/CdTe solar cell increases when the CBD CdS is annealed with oxygen before the deposition of CdTe by close spaced sublimation (CSS), while the performance of the solar cell decreases when the CBD CdS is annealed with argon-hydrogen. Electronic properties of the CdS films are investigated using X-ray photo-electron spectroscopy (XPS), which indicates that the Fermi level is shifting closer to the conduction band after annealing in the oxygen and consequently a higher open circuit voltage of the solar cell can be obtained.« less

  6. Nanoniobia modification of CdS photoanode for an efficient and stable photoelectrochemical cell.

    PubMed

    Pareek, Alka; Paik, Pradip; Borse, Pramod H

    2014-12-30

    Herein we report the surface modification of a CdS film by niobia nanoparticles via thioglycerol as an organic linker and thus fabricate an efficient and a stable photoanode for a photoelectrochemical (PEC) cell. We have synthesized three differenly sized (∼3, ∼6 ,and ∼9 nm) niobia nanoparticles by a hydrothermal synthesis approach and have further investigated the particle-size-dependent PEC performance of the nanoparticle-modified CdS photoanode. Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS) confirm the formation of Nb2O5 nanoparticles that are prepared via decomposition of the niobium peroxo complex during the hydrothermal reaction and reveal the presence of surface OH(-) groups over niobia nanoparticles that impart a high catalytic property to a material. The nano-Nb2O5-modified photoanode displayed a 23-fold higher power conversion efficiency compared to that of CdS. This modified structure increases the open circuit voltage (OCV) from 0.65 to 0.77 V, which is attributed to the nano-Nb2O5-induced surface passivation effect over bare CdS. Linking of nanoparticles on the CdS surface improves the photocorrosion stability of the CdS photoanode for even longer than 4 h in contrast to the tens of minutes for the base CdS surface. The uniform coverage of the CdS photoanode surface by niobia nanoparticles is thus found to be the controlling parameter for achieving a higher PEC performance and stability of the photoanode. This finding directed us to design an improved CdS photoanode for efficient and prolonged PEC hydrogen generation from a PEC cell.

  7. Recombinant yeast as a functional tool for understanding bitterness and cucurbitacin biosynthesis in watermelon (Citrullus spp.).

    PubMed

    Davidovich-Rikanati, Rachel; Shalev, Lior; Baranes, Nadine; Meir, Ayala; Itkin, Maxim; Cohen, Shahar; Zimbler, Kobi; Portnoy, Vitaly; Ebizuka, Yutaka; Shibuya, Masaaki; Burger, Yosef; Katzir, Nurit; Schaffer, Arthur A; Lewinsohn, Efraim; Tadmor, Ya'akov

    2015-01-01

    Cucurbitacins are a group of bitter-tasting oxygenated tetracyclic triterpenes that are produced in the family Cucurbitaceae and other plant families. The natural roles of cucurbitacins in plants are probably related to defence against pathogens and pests. Cucurbitadienol, a triterpene synthesized from oxidosqualene, is the first committed precursor to cucurbitacins produced by a specialized oxidosqualene cyclase termed cucurbitadienol synthase. We explored cucurbitacin accumulation in watermelon in relation to bitterness. Our findings show that cucurbitacins are accumulated in bitter-tasting watermelon, Citrullus lanatus var. citroides, as well as in their wild ancestor, C. colocynthis, but not in non-bitter commercial cultivars of sweet watermelon (C. lanatus var. lanatus). Molecular analysis of genes expressed in the roots of several watermelon accessions led to the isolation of three sequences (CcCDS1, CcCDS2 and ClCDS1), all displaying high similarity to the pumpkin CpCPQ, encoding a protein previously shown to possess cucurbitadienol synthase activity. We utilized the Saccharomyces cerevisiae strain BY4743, heterozygous for lanosterol synthase, to probe for possible encoded cucurbitadienol synthase activity of the expressed watermelon sequences. Functional expression of the two sequences isolated from C. colocynthis (CcCDS1 and CcCDS2) in yeast revealed that only CcCDS2 possessed cucurbitadienol synthase activity, while CcCDS1 did not display cucurbitadienol synthase activity in recombinant yeast. ClCDS1 isolated from C. lanatus var. lanatus is almost identical to CcCDS1. Our results imply that CcCDS2 plays a role in imparting bitterness to watermelon. Yeast has been an excellent diagnostic tool to determine the first committed step of cucurbitacin biosynthesis in watermelon. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Antimanic-like activity of candesartan in mice: Possible involvement of antioxidant, anti-inflammatory and neurotrophic mechanisms.

    PubMed

    de Souza Gomes, Júlia Ariana; de Souza, Greicy Coelho; Berk, Michael; Cavalcante, Lígia Menezes; de Sousa, Francisca Cléa F; Budni, Josiane; de Lucena, David Freitas; Quevedo, João; Carvalho, André F; Macêdo, Danielle

    2015-11-01

    Activation of the brain angiotensin II type 1 receptor (AT1R) triggers pro-oxidant and pro-inflammatory mechanisms which are involved in the neurobiology of bipolar disorder (BD). Candesartan (CDS) is an AT1 receptor antagonist with potential neuroprotective properties. Herein we investigated CDS effects against oxidative, neurotrophic inflammatory and cognitive effects of amphetamine (AMPH)-induced mania. In the reversal protocol adult mice were given AMPH 2 mg/kg i.p. or saline and between days 8 and 14 received CDS 0.1, 0.3 or 1 mg/kg orally, lithium (Li) 47.5 mg/kg i.p., or saline. In the prevention treatment, mice were pretreated with CDS, Li or saline prior to AMPH. Locomotor activity and working memory performance were assessed. Glutathione (GSH), thiobarbituric acid-reactive substance (TBARS) and TNF-α levels were evaluated in the hippocampus (HC) and cerebellar vermis (CV). Brain-derived neurotrophic factor (BDNF) and glycogen synthase kinase 3-beta (GSK-3beta) levels were measured in the HC. CDS and Li prevented and reversed the AMPH-induced increases in locomotor activity. Only CDS prevented and reversed AMPH-induced working memory deficits. CDS prevented AMPH-induced alterations in GSH (HC and CV), TBARS (HC and CV), TNF-α (HC and CV) and BDNF (HC) levels. Li prevented alterations in BDNF and phospho-Ser9-GSK3beta. CDS reversed AMPH-induced alterations in GSH (HC and CV), TBARS (HC), TNF-α (CV) and BDNF levels. Li reversed AMPH-induced alterations in TNF-α (HC and CV) and BDNF (HC) levels. CDS is effective in reversing and preventing AMPH-induced behavioral and biochemical alterations, providing a rationale for the design of clinical trials investigating CDS׳s possible therapeutic effects. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.

  9. Structural and Optical Properties of Core-Shell TiO2/CdS Prepared by Chemical Bath Deposition

    NASA Astrophysics Data System (ADS)

    Al-Jawad, Selma M. H.

    2017-10-01

    Titanium dioxide (TiO2) nanorod arrays (NRAs) sensitized with cadmium sulfide (CdS) nanoparticles (NPs) were deposited by chemical bath deposition (CBD). TiO2 NRAs were also obtained by using the same method on glass substrates coated with fluorine-doped tin oxide (FTO). The structure of the FTO/TiO2/CdS core-shell was characterized by x-ray diffraction (XRD), atomic force microscopy, scanning electron microscopy, ultraviolet-visible (UV-Vis) absorption spectroscopy, photoluminescence, and photoelectrocatalysis of FTO/TiO2 and FTO/TiO2/CdS. The FTO/TiO2 conformed to anatase and rutile phase structures for different pH values and also with annealing. XRD patterns of the FTO/TiO2/CdS sample exhibited two peaks corresponding to hexagonal (100) and (101) for CdS. Scanning electron micrographs showed nanorod structures for the TiO2 thin films deposited at a pH value equal 0.7. Optical results showed the CdS deposited on nanorod TiO2 exhibited increased absorption ability in the visible light, indicating an increased photocatalytic activity for TiO2/CdS core-shell nanorods in the visible light. When illuminated with a UV-Vis light source, the TiO2/CdS core-shell films displayed high responses. A composite exists between the TiO2 nanostructure and CdS NPs because the film absorbs the incident light located in both the visible and UV-Vis regions. A higher response to UV-Vis light was attained with the use of TiO2 NRAs/CdS NPs films prepared by CBD. This approach offers a technique for fabricating photoelectrodes.

  10. Evaluation of a clinical dehydration scale in children requiring intravenous rehydration.

    PubMed

    Kinlin, Laura M; Freedman, Stephen B

    2012-05-01

    To evaluate the reliability and validity of a previously derived clinical dehydration scale (CDS) in a cohort of children with gastroenteritis and evidence of dehydration. Participants were 226 children older than 3 months who presented to a tertiary care emergency department and required intravenous rehydration. Reliability was assessed at treatment initiation, by comparing the scores assigned independently by a trained research nurse and a physician. Validity was assessed by using parameters reflective of disease severity: weight gain, baseline laboratory results, willingness of the physician to discharge the patient, hospitalization, and length of stay. Interobserver reliability was moderate, with a weighted κ of 0.52 (95% confidence interval [CI] 0.41, 0.63). There was no correlation between CDS score and percent weight gain, a proxy measure of fluid deficit (Spearman correlation coefficient = -0.03; 95% CI -0.18, 0.12). There were, however, modest and statistically significant correlations between CDS score and several other parameters, including serum bicarbonate (Pearson correlation coefficient = -0.35; 95% CI -0.46, -0.22) and length of stay (Pearson correlation coefficient = 0.24; 95% CI 0.11, 0.36). The scale's discriminative ability was assessed for the outcome of hospitalization, yielding an area under the receiver operating characteristic curve of 0.65 (95% CI 0.57, 0.73). In children administered intravenous rehydration, the CDS was characterized by moderate interobserver reliability and weak associations with objective measures of disease severity. These data do not support its use as a tool to dictate the need for intravenous rehydration or to predict clinical course.

  11. Antimicrobial activity, cytotoxicity and DNA binding studies of carbon dots

    NASA Astrophysics Data System (ADS)

    Jhonsi, Mariadoss Asha; Ananth, Devanesan Arul; Nambirajan, Gayathri; Sivasudha, Thilagar; Yamini, Rekha; Bera, Soumen; Kathiravan, Arunkumar

    2018-05-01

    In recent years, quantum dots (QDs) are one of the most promising nanomaterials in life sciences community due to their unexploited potential in biomedical applications; particularly in bio-labeling and sensing. In the advanced nanomaterials, carbon dots (CDs) have shown promise in next generation bioimaging and drug delivery studies. Therefore the knowledge of the exact nature of interaction with biomolecules is of great interest to designing better biosensors. In this study, the interaction between CDs derived from tamarind and calf thymus DNA (ct-DNA) has been studied by vital spectroscopic techniques, which revealed that the CDs could interact with DNA via intercalation. The apparent association constant has been deduced from the absorption spectral changes of ct-DNA-CDs using the Benesi-Hildebrand equation. From the DNA induced emission quenching experiments the apparent DNA binding constant of the CDs (Kapp) have also been evaluated. Furthermore, we have analyzed the antibacterial and antifungal activity of CDs using disc diffusion assay method which exhibited excellent activity against E. coli and C. albicans with inhibition zone in the range of 7-12 mm. The biocompatible nature of CDs was confirmed by an in vitro cytotoxicity test on L6 normal rat myoblast cells by using MTT assay. The cell viability is not affected till the high dosage of CDs (200 μg/mL) for >48 h. As a consequence of the work, future development of CDs for microbial control and DNA sensing among the various biomolecules is possible in view of emerging biofields.

  12. Effect of silver doping on the elastic properties of CdS nanoparticles

    NASA Astrophysics Data System (ADS)

    Dey, P. C.; Das, R.

    2018-05-01

    CdS and Ag doped CdS (CdS/Ag) nanoparticles have been prepared via chemical method from a Cadmium acetate precursor and Thiourea. The synthesized CdS and CdS/Ag nanoparticles have been characterized by the X-ray Diffraction and High Resolution Transmission Electron Microscope. Here, these nanoparticles have been synthesized at room temperature and all the characterization have also been done at room temperature only. The XRD results reveal that the products are crystalline with cubic zinc blende structure. HRTEM images show that the prepared nanoparticles are nearly spherical in shape. Williamson-Hall method and Size-Strain Plot (SSP) have been used to study the individual contribution of crystalline sizes and lattice strain on the peak broadening of the CdS and CdS/Ag nanoparticles. The different modified model of Williamson-Hall method such as, uniform deformation model, uniform stress deformation model and uniform energy density deformation model and SSP method have been used to calculate the different physical parameter such as lattice strain, stress and energy density for all diffraction peaks of the XRD, corresponding to the CdS and silver doped CdS (CdS/Ag). The obtained results reveal that the average particle size of the prepared CdS and CdS/Ag nanoparticles estimated from the HRTEM images, Williamson-Hall analysis and SSP method are highly correlated with each other. Further, all these result confirms that doping of Ag significantly affects the elastic properties of CdS.

  13. Tricolor White-Light-Emitting Carbon Dots with Multiple-Cores@Shell Structure for WLED Application.

    PubMed

    Zhang, Tianyi; Zhao, Feifei; Li, Li; Qi, Bin; Zhu, Dongxia; Lü, Jianhua; Lü, Changli

    2018-06-13

    The past few years have witnessed the rapid development of carbon dots (CDs) due to their outstanding optical properties and a wide range of applications. However, the design and control of CDs with long-wavelength multicolor emission are still huge challenges to be addressed for their practical use in different fields. Here, novel nitrogen-doped multiple-core@shell-structured AC-CDs with tricolor emissions of red, green, and blue were constructed via one-pot hydrothermal method from 5-amino-1,10-phenanthroline and citric acid as reactants and the growth process of AC-CDs was monitored with the reaction time in the synthetic system. The origin of different fluorescence emissions was explored using the unique coordination ability of the surface groups of AC-CDs. An obvious concentration dependence of fluorescent properties was observed for the as-prepared AC-CDs, and a highly fluorescent quantum yield (QY) of 67% for red emission at 630 nm can be obtained by adjusting concentration of AC-CDs. The pure white-light emission (0.33, 0.33; Commission Internationale de l'Elcairage coordinate) was carried out from single carbon dot with QY of 29% through regulation of the excitation and concentration of multiple-core@shell-structured AC-CDs. In addition, because of their excellent photoluminescent properties, the white-emitting AC-CDs as emitting phosphor can be easily used in the fabrication of white-light-emitting diode with good anti-photobleaching and temperature stability.

  14. Turn-off fluorescence sensor for the detection of ferric ion in water using green synthesized N-doped carbon dots and its bio-imaging.

    PubMed

    Edison, Thomas Nesakumar Jebakumar Immanuel; Atchudan, Raji; Shim, Jae-Jin; Kalimuthu, Senthilkumar; Ahn, Byeong-Cheol; Lee, Yong Rok

    2016-05-01

    This paper reports turn-off fluorescence sensor for Fe(3+) ion in water using fluorescent N-doped carbon dots as a probe. A simple and efficient hydrothermal carbonization of Prunus avium fruit extract for the synthesis of fluorescent nitrogen-doped carbon dots (N-CDs) is described. This green approach proceeds quickly and provides good quality N-CDs. The mean size of synthesized N-CDs was approximately 7nm calculated from the high-resolution transmission electron microscopic images. X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy revealed the presence of -OH, -NH2, -COOH, and -CO functional groups over the surface of CDs. The N-CDs showed excellent fluorescent properties, and emitted blue fluorescence at 411nm upon excitation at 310nm. The calculated quantum yield of the synthesized N-CDs is 13% against quinine sulfate as a reference fluorophore. The synthesized N-CDs were used as a fluorescent probe towards the selective and sensitive detection of biologically important Fe(3+) ions in water by fluorescence spectroscopy and for bio-imaging of MDA-MB-231 cells. The limit of detection (LOD) and the Stern-Volmer quenching constant for the synthesized N-CDs were 0.96μM and 2.0958×10(3)M of Fe(3+) ions. The green synthesized N-CDs are efficiently used as a promising candidate for the detection of Fe(3+) ions and bio-imaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. National trends in safety performance of electronic health record systems in children's hospitals.

    PubMed

    Chaparro, Juan D; Classen, David C; Danforth, Melissa; Stockwell, David C; Longhurst, Christopher A

    2017-03-01

    To evaluate the safety of computerized physician order entry (CPOE) and associated clinical decision support (CDS) systems in electronic health record (EHR) systems at pediatric inpatient facilities in the US using the Leapfrog Group's pediatric CPOE evaluation tool. The Leapfrog pediatric CPOE evaluation tool, a previously validated tool to assess the ability of a CPOE system to identify orders that could potentially lead to patient harm, was used to evaluate 41 pediatric hospitals over a 2-year period. Evaluation of the last available test for each institution was performed, assessing performance overall as well as by decision support category (eg, drug-drug, dosing limits). Longitudinal analysis of test performance was also carried out to assess the impact of testing and the overall trend of CPOE performance in pediatric hospitals. Pediatric CPOE systems were able to identify 62% of potential medication errors in the test scenarios, but ranged widely from 23-91% in the institutions tested. The highest scoring categories included drug-allergy interactions, dosing limits (both daily and cumulative), and inappropriate routes of administration. We found that hospitals with longer periods since their CPOE implementation did not have better scores upon initial testing, but after initial testing there was a consistent improvement in testing scores of 4 percentage points per year. Pediatric computerized physician order entry (CPOE) systems on average are able to intercept a majority of potential medication errors, but vary widely among implementations. Prospective and repeated testing using the Leapfrog Group's evaluation tool is associated with improved ability to intercept potential medication errors. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  16. Rapid Synthesis of Carbon Dots by Hydrothermal Treatment of Lignin

    PubMed Central

    Chen, Wenxin; Hu, Chaofan; Yang, Yunhua; Cui, Jianghu; Liu, Yingliang

    2016-01-01

    A rapid approach has been developed for the fluorescent carbon dots (CDs) by the hydrothermal treatment of lignin in the presence of H2O2. The as-synthesized CDs were found to emit blue photoluminescence with excellent photostability. Moreover, the CDs displayed biocompatibility, low cytotoxicity, and high water solubility properties. Finally, the as-resulted CDs were demonstrated to be excellent probes for bioimaging and biosensing applications. PMID:28773309

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Bo; Zhang, Xiaosong, E-mail: zhangxiaosong@tjut.edu.cn; Li, Lan

    Trap-rich CdS nanocrystals were synthesized by employing CdSt{sub 2} and sulfur as precursors via thermal decomposition. Furthermore, X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), absorption and photoluminescence (PL) spectra were used to characterize structure, morphology and luminescence properties of CdS nanocrystals (NCs). CdS NCs have a broad emission across 500–700 nm under the excitation of blue light with 460 nm, consequently, white light can be produced by mixing broad emission from CdS NCs excited by blue light, with the remaining blue light. In addition, the broad emission generation is closely and inseparably related to surface defects. Moreover, LaMer modelmore » was used to explain the phenomenon that the intensity of the trap emission gradually decreases as the reaction time increases in contrast with that of the band-edge emission. - Graphical abstract: Trap-rich CdS nanocrystals were synthesized. Furthermore, white light is produced by mixing broad emission across 500–700 nm from CdS NCs excited by blue light, in combination with the remaining blue light. - Highlights: • Trap-rich CdS nanocrystals were synthesized. • CdS NCs have a broad emission across 500–700 nm under the excitation of blue light. • White light can be produced by mixing broad emission with the remaining blue light.« less

  18. One-step hydrothermal synthesis of chiral carbon dots and their effects on mung bean plant growth.

    PubMed

    Zhang, Mengling; Hu, Lulu; Wang, Huibo; Song, Yuxiang; Liu, Yang; Li, Hao; Shao, Mingwang; Huang, Hui; Kang, Zhenhui

    2018-06-27

    Chiral compounds/materials have important effects on the growth of plants. Chiral carbon dots (CDs), as an emerging chiral carbon nanomaterial, have great potential in bio-application and bio-nanotechnology. Herein, we report a hydrothermal method to synthesize chiral CDs from cysteine (cys) and citric acid. These chiral CDs were further demonstrated to have systemic effects on the growth of mung bean plants, in which case both l- and d-CDs can promote the growth of the root in mung bean plants, stem length of mung bean sprouts and water absorption of bean seeds. The elongation of mung bean sprouts presented an increasing trend with the treatment of chiral CDs of increasing concentration (below 500 μg mL-1). Furthermore, in the optimal concentration (100 μg mL-1), the l-CDs can improve root vigor and the activity of the Rubisco enzyme of bean sprouts by 8.4% and 20.5%, while the d-CDs increased by 28.9% and 67.5%. Due to more superior properties in improving root vigor and the activity of the Rubisco enzyme of mung bean sprouts, d-CDs are able to enhance photosynthesis better and accumulate more carbohydrate in mung bean plants.

  19. Ultrasensitive detection of amifostine and alkaline phosphatase based on the growth of CdS quantum dots.

    PubMed

    Na, Weidan; Liu, Siyu; Liu, Xiaotong; Su, Xingguang

    2015-11-01

    In this study, we reported a simple and sensitive fluorescence nanosensor for rapid detection of amifostine and alkaline phosphatase (ALP). The novel nanosensor was based on the fluorescence "turn on-off" of CdS quantum dots (QDs). Firstly, Cd(2+) cation could react with S(2-) anion to generate fluorescent CdS QDs in the presence of amifostine. The fluorescence (FL) intensity of amifostine-capped CdS QDs (Amifostine-CdS QDs) was increased with the increasing amounts of amifostine, and could be used for amifostine detection. However, amifostine could be converted to 2-(3-aminopropylamino) ethanethiol (WR1065) in the presence of ALP based on the dephosphorylation of ALP. Under the optimum conditions, the affinity of WR1065 to CdS QDs was weaker than that of amifostine. Therefore the new generation of WR1065-CdS QDs would reduce the FL intensity with the increase of ALP concentration, and the fluorescence of CdS QDs was turn off. The metabolic process of amifostine in the presence of alkaline phosphatase could be also studied via the change of FL intensity of CdS QDs. The present method was cost-effective, convenient, and does not require any complicated synthetic procedures. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. One-pot synthesis of CdS nanocrystals hybridized with single-layer transition-metal dichalcogenide nanosheets for efficient photocatalytic hydrogen evolution.

    PubMed

    Chen, Junze; Wu, Xue-Jun; Yin, Lisha; Li, Bing; Hong, Xun; Fan, Zhanxi; Chen, Bo; Xue, Can; Zhang, Hua

    2015-01-19

    Exploration of low-cost and earth-abundant photocatalysts for highly efficient solar photocatalytic water splitting is of great importance. Although transition-metal dichalcogenides (TMDs) showed outstanding performance as co-catalysts for the hydrogen evolution reaction (HER), designing TMD-hybridized photocatalysts with abundant active sites for the HER still remains challenge. Here, a facile one-pot wet-chemical method is developed to prepare MS2-CdS (M=W or Mo) nanohybrids. Surprisedly, in the obtained nanohybrids, single-layer MS2 nanosheets with lateral size of 4-10 nm selectively grow on the Cd-rich (0001) surface of wurtzite CdS nanocrystals. These MS2-CdS nanohybrids possess a large number of edge sites in the MS2 layers, which are active sites for the HER. The photocatalytic performances of WS2-CdS and MoS2-CdS nanohybrids towards the HER under visible light irradiation (>420 nm) are about 16 and 12 times that of pure CdS, respectively. Importantly, the MS2-CdS nanohybrids showed enhanced stability after a long-time test (16 h), and 70% of catalytic activity still remained. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. MWCNT/CdS hybrid nanocomposite for enhanced photocatalytic activity

    NASA Astrophysics Data System (ADS)

    Chaudhary, Deepti; Khare, Neeraj; Vankar, V. D.

    2016-05-01

    Multi-walled carbon nanotubes (MWCNT)/CdS hybrid nanocomposite were synthesized by one step hydrothermal method. MWCNTs were used as a substrate for the growth of CdS nanoparticles. MWCNT/CdS nanocomposite and pure CdS were characterized by XRD, TEM, UV-vis and photoluminescence spectroscopy. HRTEM study confirms the intimate contact of CdS with MWCNT. The photocatalytic activity of nanocomposite was studied for the degradation of methylene blue dye under UV irradiation. The enhanced photocatalytic activity of MWCNT/CdS nanocomposite as compared to pure CdS has been attributed to reduced recombination of photogenerated charge carriers due to interfacial electron transfer from CdS to MWCNT.

  2. CdS nanoparticles immobilized on porous carbon polyhedrons derived from a metal-organic framework with enhanced visible light photocatalytic activity for antibiotic degradation

    NASA Astrophysics Data System (ADS)

    Yang, Cao; Cheng, Jianhua; Chen, Yuancai; Hu, Yongyou

    2017-10-01

    The CdS/MOF-derived porous carbon (MPC) composite as an efficient visible-light-driven photocatalyst was prepared through the pyrolysis of ZIF-8 and subsequent growth of CdS. The porous and functionalized MPC enables intimate and discrete growth of CdS nanoparticles. This unique structure not only reduces the bulk recombination owing to nano-size effect of CdS, but also suppresses the surface recombination due to the discrete growth of CdS nanoparticles on MPC polyhedrons, which facilitates electron transfer and charge separation. Moreover, such a composite material possessed good adsorption ability toward the antibiotic pollutants because of the amino-functionalized surface. As a result, the as-prepared CdS/MPC composites showed excellent photocatalytic performance for the antibiotic degradation, significantly improving the photoactivity of CdS. Importantly, the CdS/MPC composite with the CdS loading of 20 wt% exhibited the highest photocatalytic efficiency of approximately 91% and apparent rate constant of 0.024 min-1.

  3. Synthesis of pore-variable mesoporous CdS and evaluation of its photocatalytic activity in degrading methylene blue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Wei-Min, E-mail: chm_zhangwm@ujn.edu.cn; Jiang, Yao-Quan; Cao, Xiao-Yan

    2013-10-15

    Graphical abstract: - Highlights: • Self-templated synthesis of tubular CdS. • Cadmium complexes of aliphatic acids sustain the network of mesoporous structures. • Aliphatic acids affect the phase composition and particle size. • Pore size and volume vary with aliphatic acids having different hydrocarbonyl. - Abstract: In this study, mesoporous CdS polycrystallites have been synthesized using aliphatic acids of hexanoic acid, octanoic acid, and oleic acid as coordinating and capping agents, respectively. The fibrous Cd–fatty acid salts act as a template to form the tubular CdS. The organic species are found to be necessary for maintaining the network of mesoporousmore » CdS. The characterization results indicate that the shorter carbon chain length in aliphatic acids favors the wurtzite phase and particle size growth the specific surface area, pore diameter and pore volume show a monotonic raise with increasing carbon chain. The photocatalytic activities of mesoporous CdS tubes exhibit much higher efficiency than those of nanosized CdS powders in decolorizing methylene blue under simulated visible light.« less

  4. Structural and Spectroscopic Studies of Sm3+/CdS Nanocrystallites in Sol-Gel TiO2-ZrO2 Matrix

    NASA Astrophysics Data System (ADS)

    Karthika, S.; Prathibha, Vasudevan; Ann, Mary K. A.; Viji, Vidyadharan; Biju, P. R.; Unnikrishnan, N. V.

    2014-02-01

    A sol-gel method was used to prepare titania-zirconia matrices doped with Sm3+/CdS nanocrystallites. The structural properties of the matrices were characterized using transmission electron microscopy (TEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA), and Fourier-transform infrared spectroscopy studies. The thermal stability of the material was determined by TGA/DTA analysis. The absorption spectrum shows the characteristic peaks of the Sm3+ ions and the absorption peak corresponding to the CdS nanocrystallites. The optical bandgap and size of the CdS nanoparticles were calculated from the absorption spectrum. From TEM, the interplanar distance ( d) was estimated to be 3.533 Å, which matches with the (1 0 0) plane of bulk CdS. The measurements yield a nanocrystallite size of around 7.8 nm. The optical absorption and emission spectra confirmed the formation of CdS nanoparticles along with samarium ions in the titania-zirconia matrices. The fluorescence intensity of the samarium ions was found to be greatly enhanced by codoping with CdS nanocrystallites.

  5. Effects of air annealing on CdS quantum dots thin film grown at room temperature by CBD technique intended for photosensor applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaikh, Shaheed U.; Desale, Dipalee J.; Siddiqui, Farha Y.

    2012-11-15

    Graphical abstract: The effect of different intensities (40, 60 100 and 200 W) of light on CdS quantum dots thin film annealed at 350 °C indicating enhancement in (a) photo-current and (b) photosensitivity. Highlights: ► The preparation of CdS nanodot thin film at room temperature by M-CBD technique. ► Study of air annealing on prepared CdS nanodots thin film. ► The optimized annealing temperature for CdS nanodot thin film is 350 °C. ► Modified CdS thin films can be used in photosensor application. -- Abstract: CdS quantum dots thin-films have been deposited onto the glass substrate at room temperature usingmore » modified chemical bath deposition technique. The prepared thin films were further annealed in air atmosphere at 150, 250 and 350 °C for 1 h and subsequently characterized by scanning electron microscopy, ultraviolet–visible spectroscopy, electrical resistivity and I–V system. The modifications observed in morphology and opto-electrical properties of the thin films are presented.« less

  6. Additive interaction of carbon dots extracted from soluble coffee and biogenic silver nanoparticles against bacteria

    NASA Astrophysics Data System (ADS)

    Andrade, Patricia F.; Nakazato, Gerson; Durán, Nelson

    2017-06-01

    It is known the presence of carbon dots (CDs) in carbohydrate based foods. CDs extracted from coffee grounds and instant coffee was also published. CDs from soluble coffee revealed an average size of 4.4 nm. CDs were well-dispersed in water, fluorescent and we have characterized by XPS, XRD analysis, fluorescence and by FTIR spectra. The MIC value by serial micro-dilution assays for CDs on S. aureus ATCC 25923 was 250 μg/mL and E. coli ATCC 25922 >1000 ug/mL. For silver nanoparticles biogenically synthesized was 6.7 μg/mL. Following the checkerboard assay with combining ½ MIC values of the MICs of 125 μg/mL of carbon dots and 3.4 μg/mL of silver nanoparticles, following the fractionated inhibitory concentration (FIC) index methodology, on S. aureus gave a fractionated inhibitory concentration (FIC) value of 1.0, meaning additive interaction. In general, the unfunctionalized CDs showed to be inefficient as antibacterial compounds, however the CDs extracted from Coffee powder and together silver nanoparticles appeared interesting as antibacterial association.

  7. Damage tolerance protein Mus81 associates with the FHA1 domain of checkpoint kinase Cds1.

    PubMed

    Boddy, M N; Lopez-Girona, A; Shanahan, P; Interthal, H; Heyer, W D; Russell, P

    2000-12-01

    Cds1, a serine/threonine kinase, enforces the S-M checkpoint in the fission yeast Schizosaccharomyces pombe. Cds1 is required for survival of replicational stress caused by agents that stall replication forks, but how Cds1 performs these functions is largely unknown. Here we report that the forkhead-associated-1 (FHA1) protein-docking domain of Cds1 interacts with Mus81, an evolutionarily conserved damage tolerance protein. Mus81 has an endonuclease homology domain found in the XPF nucleotide excision repair protein. Inactivation of mus81 reveals a unique spectrum of phenotypes. Mus81 enables survival of deoxynucleotide triphosphate starvation, UV radiation, and DNA polymerase impairment. Mus81 is essential in the absence of Bloom's syndrome Rqh1 helicase and is required for productive meiosis. Genetic epistasis studies suggest that Mus81 works with recombination enzymes to properly replicate damaged DNA. Inactivation of Mus81 triggers a checkpoint-dependent delay of mitosis. We propose that Mus81 is involved in the recruitment of Cds1 to aberrant DNA structures where Cds1 modulates the activity of damage tolerance enzymes.

  8. Effects of experimental conditions on the morphologies, structures and growth modes of pulsed laser-deposited CdS nanoneedles

    PubMed Central

    2014-01-01

    CdS nanoneedles with different morphologies, structures, and growth modes have been grown on Ni-coated Si(100) surface under different experimental conditions by pulsed laser deposition method. The effects of catalyst layer, substrate temperature, and laser pulse energy on the growth of the CdS nanoneedles were studied in detail. It was confirmed that the formation of the molten catalyst spheres is the key to the nucleation of the CdS nanoneedles by observing the morphologies of the Ni catalyst thin films annealed at different substrate temperatures. Both the substrate temperature and laser pulse energy strongly affected the growth modes of the CdS nanoneedles. The secondary growth of the smaller nanoneedles on the top of the main nanoneedles was found at appropriate conditions. A group of more completed pictures of the growth modes of the CdS nanoneedles were presented. PMID:24559455

  9. Hydrothermal synthesis of nitrogen-doped carbon dots with real-time live-cell imaging and blood-brain barrier penetration capabilities.

    PubMed

    Lu, Shousi; Guo, Shanshan; Xu, Pingxiang; Li, Xiaorong; Zhao, Yuming; Gu, Wei; Xue, Ming

    Nitrogen-doped carbon dots (N-CDs) were synthesized using a one-pot hydrothermal treatment with citric acid in the presence of polyethylenimine. Transmission electron microscopy analysis revealed that the N-CDs were monodispersed and quasi-spherical with an average size of ~2.6 nm. Under ultraviolet irradiation the N-CDs emitted a strong blue luminescence with a quantum yield as high as 51%. Moreover, the N-CDs exhibited a negligible cytotoxicity and could be applied as efficient nanoprobes for real-time imaging of live cells. In addition, the ability of the N-CDs to cross the blood-brain barrier (BBB) in a concentration-dependent manner was demonstrated using an in vitro BBB model. Therefore, these PEI-passivated N-CDs with real-time live-cell imaging and BBB-penetration capabilities hold promise for traceable drug delivery to the brain.

  10. Highly fluorescent carbon dots for visible sensing of doxorubicin release based on efficient nanosurface energy transfer.

    PubMed

    Wang, Beibei; Wang, Shujun; Wang, Yanfang; Lv, Yan; Wu, Hao; Ma, Xiaojun; Tan, Mingqian

    2016-01-01

    To prepare fluorescent carbon dots for loading cationic anticancer drug through donor-quenched nanosurface energy transfer in visible sensing of drug release. Highly fluorescent carbon dots (CDs) were prepared by a facile hydrothermal approach from citric acid and o-phenylenediamine. The obtained CDs showed a high quantum yield of 46 % and exhibited good cytocompatibility even at 1 mg/ml. The cationic anticancer drug doxorubicin (DOX) can be loaded onto the negatively charged CDs through electrostatic interactions. Additionally, the fluorescent CDs feature reversible donor-quenched mode nanosurface energy transfer. When loading the energy receptor DOX, the donor CDs' fluorescence was switched "off", while it turned "on" again after DOX release from the surface through endocytic uptake. Most DOX molecules were released from the CDs after 6 h incubation and entered cell nuclear region after 8 h, suggesting the drug delivery system may have potential for visible sensing in drug release.

  11. One-pot synthesis of fluorescent nitrogen-doped carbon dots with good biocompatibility for cell labeling.

    PubMed

    Zhang, Zhengwei; Yan, Kun; Yang, Qiulian; Liu, Yanhua; Yan, Zhengyu; Chen, Jianqiu

    2017-12-01

    Here we report an easy and economical hydrothermal carbonization approach to synthesize the fluorescent nitrogen-doped carbon dots (N-CDs) that was developed using citric acid and triethanolamine as the precursors. The synthesis conditions were optimized to obtain the N-CDs with superior fluorescence performances. The as-prepared N-CDs are monodispersed sphere nanoparticles with good water solubility, and exhibited strong fluorescence, favourable photostability and excitation wavelength-dependent behavior. Furthermore, the in vitro cytotoxicity and cellular labeling of N-CDs were investigated using the rat glomerular mesangial cells. The results showed the N-CDs have more inconspicuous cytotoxicity and better biosafety in comparison with ZnSe quantum dots, although both targeted the cells successfully. Considering their admirable photostability, low toxicity and good compatibility, the as-obtained N-CDs could have potential applications in biosensors, cellular imaging, and other fields. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Hydrothermal synthesis of nitrogen-doped carbon dots with real-time live-cell imaging and blood–brain barrier penetration capabilities

    PubMed Central

    Lu, Shousi; Guo, Shanshan; Xu, Pingxiang; Li, Xiaorong; Zhao, Yuming; Gu, Wei; Xue, Ming

    2016-01-01

    Nitrogen-doped carbon dots (N-CDs) were synthesized using a one-pot hydrothermal treatment with citric acid in the presence of polyethylenimine. Transmission electron microscopy analysis revealed that the N-CDs were monodispersed and quasi-spherical with an average size of ~2.6 nm. Under ultraviolet irradiation the N-CDs emitted a strong blue luminescence with a quantum yield as high as 51%. Moreover, the N-CDs exhibited a negligible cytotoxicity and could be applied as efficient nanoprobes for real-time imaging of live cells. In addition, the ability of the N-CDs to cross the blood–brain barrier (BBB) in a concentration-dependent manner was demonstrated using an in vitro BBB model. Therefore, these PEI-passivated N-CDs with real-time live-cell imaging and BBB-penetration capabilities hold promise for traceable drug delivery to the brain. PMID:27932880

  13. [Screening for depersonalization-derealization with two items of the cambridge depersonalization scale].

    PubMed

    Michal, Matthias; Zwerenz, Rüdiger; Tschan, Regine; Edinger, Jens; Lichy, Marcel; Knebel, A; Tuin, Inka; Beutel, Manfred

    2010-05-01

    Depersonalization (DP) and derealization (DR) are considered to be highly underdiagnosed. Therefore the development of screening instruments is important. From the Cambridge Depersonalization Scale (CDS) two items were extracted discriminating best patients with clinical significant DP from patients without DP. These two Items were assembled to a short version of the CDS. This short version (CDS-2) was tested in a sample of 38 patients with clinical significant DP-DR and 49 patients without or only mild DP-DR. Scores were compared against clinical diagnoses based on a structured interview (gold standard). The CDS-2 was able to differentiate patients with clinical significant DP well from other groups (cut-off of CDS-2>or=3, sensitivity=78.9%, specifity=85.7%) and also showed high reliability (Cronbachs alpha=0.92). Therefore the CDS-2 can be considered as a useful tool for screening and identification of DP-DR.

  14. Cultivating Fluorescent Flowers with Highly Luminescent Carbon Dots Fabricated by a Double Passivation Method.

    PubMed

    Han, Shuai; Chang, Tao; Zhao, Haiping; Du, Huanhuan; Liu, Shan; Wu, Baoshuang; Qin, Shenjun

    2017-07-07

    In this work, we present the fabrication of highly luminescent carbon dots (CDs) by a double passivation method with the assistance of Ca(OH)₂. In the reaction process, Ca 2+ protects the active functional groups from overconsumption during dehydration and carbonization, and the electron-withdrawing groups on the CD surface are converted to electron-donating groups by the hydroxyl ions. As a result, the fluorescence quantum yield of the CDs was found to increase with increasing Ca(OH)₂ content in the reaction process. A blue-shift optical spectrum of the CDs was also found with increasing Ca(OH)₂ content, which could be attributed to the increasing of the energy gaps for the CDs. The highly photoluminescent CDs obtained (quantum yield: 86%) were used to cultivate fluorescent carnations by a water culture method, while the results of fluorescence microscopy analysis indicated that the CDs had entered the plant tissue structure.

  15. Designing Multi-Channel Web Frameworks for Cultural Tourism Applications: The MUSE Case Study.

    ERIC Educational Resources Information Center

    Garzotto, Franca; Salmon, Tullio; Pigozzi, Massimiliano

    A framework for the design of multi-channel (MC) applications in the cultural tourism domain is presented. Several heterogeneous interface devices are supported including location-sensitive mobile units, on-site stationary devices, and personalized CDs that extend the on-site experience beyond the visit time thanks to personal memories gathered…

  16. Reliability and validity of a Japanese version of the Cambridge depersonalization scale as a screening instrument for depersonalization disorder.

    PubMed

    Sugiura, Miyuki; Hirosawa, Masataka; Tanaka, Sumio; Nishi, Yasunobu; Yamada, Yasuyuki; Mizuno, Motoki

    2009-06-01

    The Cambridge Depersonalization Scale (CDS) is an instrument that has obtained reliability and validity in some countries for use in detecting depersonalization disorder under clinical conditions, but not yet in Japan under non-psychiatric conditions. The purposes of this study were to develop a Japanese version of the CDS (J-CDS) and to examine its reliability and validity as an instrument for screening depersonalization disorder under non-clinical conditions. The CDS was translated from English into Japanese and then back-translated into English by a native English-speaking American. After making the J-CDS, we examined its reliability and validity. Questionnaires that were composed of J-CDS, the Dissociative Experience Scale (DES), the Zung self-rating scale and the Maudsley Obsessional-Compulsive Inventory were administrated to 59 participants (12 patients with depersonalization disorder, 11 individuals who had recovered from depersonalization and 36 healthy controls). Cronbach's alpha and split-half reliability were 0.94 and 0.93, respectively. The J-CDS score in the depersonalization group was significantly higher than in the healthy control group. The J-CDS score was significantly correlated with scores of total DES, and DES-depersonalization. The best compromise between the true positive and false negative rate was at a cut-off point of 60, yielding a sensitivity of 1.00 and a specificity of 0.96. In this study, J-CDS showed good reliability and validity. The best cut-off point, when we use this for distinguishing individuals with depersonalization disorder from individuals without psychiatric disorders, is 60 points.

  17. Examining perceptions of the usefulness and usability of a mobile-based system for pharmacogenomics clinical decision support: a mixed methods study

    PubMed Central

    Blagec, Kathrin; Romagnoli, Katrina M.; Boyce, Richard D.

    2016-01-01

    Background. Pharmacogenomic testing has the potential to improve the safety and efficacy of pharmacotherapy, but clinical application of pharmacogenetic knowledge has remained uncommon. Clinical Decision Support (CDS) systems could help overcome some of the barriers to clinical implementation. The aim of this study was to evaluate the perception and usability of a web- and mobile-enabled CDS system for pharmacogenetics-guided drug therapy–the Medication Safety Code (MSC) system–among potential users (i.e., physicians and pharmacists). Furthermore, this study sought to collect data on the practicability and comprehensibility of potential layouts of a proposed personalized pocket card that is intended to not only contain the machine-readable data for use with the MSC system but also human-readable data on the patient’s pharmacogenomic profile. Methods. We deployed an emergent mixed methods design encompassing (1) qualitative interviews with pharmacists and pharmacy students, (2) a survey among pharmacogenomics experts that included both qualitative and quantitative elements and (3) a quantitative survey among physicians and pharmacists. The interviews followed a semi-structured guide including a hypothetical patient scenario that had to be solved by using the MSC system. The survey among pharmacogenomics experts focused on what information should be printed on the card and how this information should be arranged. Furthermore, the MSC system was evaluated based on two hypothetical patient scenarios and four follow-up questions on the perceived usability. The second survey assessed physicians’ and pharmacists’ attitude towards the MSC system. Results. In total, 101 physicians, pharmacists and PGx experts coming from various relevant fields evaluated the MSC system. Overall, the reaction to the MSC system was positive across all investigated parameters and among all user groups. The majority of participants were able to solve the patient scenarios based on the recommendations displayed on the MSC interface. A frequent request among participants was to provide specific listings of alternative drugs and concrete dosage instructions. Negligence of other patient-specific factors for choosing the right treatment such as renal function and co-medication was a common concern related to the MSC system, while data privacy and cost-benefit considerations emerged as the participants’ major concerns regarding pharmacogenetic testing in general. The results of the card layout evaluation indicate that a gene-centered and tabulated presentation of the patient’s pharmacogenomic profile is helpful and well-accepted. Conclusions. We found that the MSC system was well-received among the physicians and pharmacists included in this study. A personalized pocket card that lists a patient’s metabolizer status along with critically affected drugs can alert physicians and pharmacists to the availability of essential therapy modifications. PMID:26925317

  18. Single-Source Molecular Precursor for Synthesis of CdS Nanoparticles and Nanoflowers

    NASA Astrophysics Data System (ADS)

    Salavati-Niasari, Masoud; Sobhani, Azam

    2012-04-01

    CdS Semiconductor nanostructures were synthesized by using two different methods. Using triphenylphosphine (C18H15P) and oleylamine (C18H37N) as surfactant, CdS semiconductor nanocrystals with a size ranging from 30 to 90 nm can be synthesized by thermal decomposition of precursor [bis(thiosemicarbazide)cadmium(II)]. CdS nanoflowers were synthesized via hydrothermal decomposition of [bis(thiosemicarbazide) cadmium(II)] without any surfactant. X-ray diffraction (XRD) patterns confirm that the resulting samples were a pure hexagonal phase of CdS. The optical property test indicates that the absorption peak of the samples shifts towards short wavelength, and the blue shift phenomenon might be ascribed to the quantum effect.

  19. Growth and characterization of EDTA assisted CBD-CdS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumarage, W. G. C.; Wijesundera, R. P.; Seneviratne, V. A.

    2017-10-01

    Chemical bath deposition of CdS (CBD-CdS) thin films with the assistance of a cationic surfactant, ethylenediamine tetraacetic acid (EDTA), is reported in this work. Also the EDTA treated CdS thin films are compared with that of conventional CBD-CdS. Fabricated thin, compact, uniform and adherent EDTA treated CdS films show enhanced effective surface area and roughness compared to conventional CBD-CdS. The grazing incidence x-ray diffraction analysis shows all the fabricated CdS films are hexagonally crystallized. EDTA-treated CdS films show excellent photo activity compared to conventional CBDCdS. The flat band potential (Vfb) value was found to be tunable with EDTA concentration.

  20. Facile synthesis of carbon dots with superior sensing ability

    NASA Astrophysics Data System (ADS)

    Jin, Lin; Li, Jingguo; Liu, Liyun; Wang, Zhenling; Zhang, Xingcai

    2018-04-01

    Carbon dots (CDs) have various applications in biomedical and environmental field, such as bio-imaging, bio-sensing and heavy metal detection. In this study, a novel class of CDs were synthesized using a one-step hydrothermal method. The fabricated CDs displayed stable photoluminescence, good water solubility, and photo stability. Moreover, the functional groups (carboxylic acid moieties and hydroxyls) on the surface of the obtained CDs enable it with superior sensing ability (e.g., very low detectable concentration for Pb2+: 5 nmol/L). With superior detection sensitivity, excellent fluorescent properties and facile fabrication method, the as-obtained CDs can find practical applications as cost-effective and sensitive chemo-sensors in water and food safety field.

  1. CDS Re Mix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    CDS (Change Detection Systems) is a mechanism for rapid visual analysis using complex image alignment algorithms. CDS is controlled with a simple interface that has been designed for use for anyone that can operate a digital camera. A challenge of complex industrial systems like nuclear power plants is to accurately identify changes in systems, structures and components that may critically impact the operation of the facility. CDS can provide a means of early intervention before the issues evolve into safety and production challenges.

  2. Improved Dynamic Modeling of the Cascade Distillation Subsystem and Analysis of Factors Affecting Its Performance

    NASA Technical Reports Server (NTRS)

    Perry, Bruce A.; Anderson, Molly S.

    2015-01-01

    The Cascade Distillation Subsystem (CDS) is a rotary multistage distiller being developed to serve as the primary processor for wastewater recovery during long-duration space missions. The CDS could be integrated with a system similar to the International Space Station Water Processor Assembly to form a complete water recovery system for future missions. A preliminary chemical process simulation was previously developed using Aspen Custom Modeler® (ACM), but it could not simulate thermal startup and lacked detailed analysis of several key internal processes, including heat transfer between stages. This paper describes modifications to the ACM simulation of the CDS that improve its capabilities and the accuracy of its predictions. Notably, the modified version can be used to model thermal startup and predicts the total energy consumption of the CDS. The simulation has been validated for both NaC1 solution and pretreated urine feeds and no longer requires retuning when operating parameters change. The simulation was also used to predict how internal processes and operating conditions of the CDS affect its performance. In particular, it is shown that the coefficient of performance of the thermoelectric heat pump used to provide heating and cooling for the CDS is the largest factor in determining CDS efficiency. Intrastage heat transfer affects CDS performance indirectly through effects on the coefficient of performance.

  3. Carbon dots-decorated multiwalled carbon nanotubes nanocomposites as a high-performance electrochemical sensor for detection of H2O2 in living cells.

    PubMed

    Bai, Jing; Sun, Chunhe; Jiang, Xiue

    2016-07-01

    A novel enzyme-free hydrogen peroxide sensor composed of carbon dots (CDs) and multi-walled carbon nanotubes (MWCNTs) was prepared. It was found that the carbon dots-decorated multi-walled carbon nanotubes nanocomposites (CDs/MWCNTs) modified glassy carbon (GC) electrode (CDs/MWCNTs/GCE) exhibited a significant synergistic electrocatalytic activity towards hydrogen peroxide reduction as compared to carbon dots or multi-walled carbon nanotubes alone, and the CDs/MWCNTs/GCE has shown a low detection limit as well as excellent stability, selectivity, and reproducibility. These remarkable analytical advantages enable the practical application of CDs/MWCNTs/GCE for the real-time tracking of hydrogen peroxide (H2O2) released from human cervical cancer cells with satisfactory results. The enhanced electrochemical activity can be assigned to the edge plane-like defective sites and lattice oxygen in the CDs/MWCNTs nanocomposites due to the small amount of decoration of carbon dots on the multi-walled carbon nanotubes. Based on a facile preparation method and with good electrochemical properties, the CDs/MWCNTs nanocomposites represent a new class of carbon electrode for electrochemical sensor applications. Graphical Abstract CDs/MWCNTs exhibited good electrocatalytic activity and stability to H2O2 reduction and can be used for real-time detection of H2O2 released from living cells.

  4. One-pot synthesis and lubricity of fluorescent carbon dots applied on PCL-PEG-PCL hydrogel.

    PubMed

    Guo, Junde; Mei, Tangjie; Li, Yue; Hafezi, Mahshid; Lu, Hailin; Li, Jianhui; Dong, Guangneng

    2018-06-12

    This work presents a method for one-pot synthesis of N-doped nanometer-size carbon dots, which can be assembled with thermosensitive poly(ε-caprolactone)-poly(ethylene glycol)-poly(ε-caprolactone) (PCL-PEG-PCL, PCEC) hydrogel to achieve slow-release lubricity. The typical property of this green production was studied by fourier transform infrared (FT-IR), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and transmission electron microscope (TEM). The photoluminescence of composite PCEC/CDs hydrogel and its released solutions were characterized by ultraviolet spectrum, and the rheological properties were tested by rotary rheometer. Tribological performance of the released solution from composite PCEC/CDs hydrogel was obtained to compare with PBS and pure CDs solution. The experimental results reveal that the CDs contain the chemical groups of N-H, C-OH/C-O-C and -COOH, etc. In addition, the diameter of the CDs is in the range of 6~8 nm. The phase transition behavior of PCEC/CDs hydrogel can be still kept and its viscoelasticity hydrogel is improved by approximatively 7%. Furthermore, friction coefficient of the released solution from composite PCEC/CDs hydrogel decreases by about 70% than that of PBS. Besides, the wear condition can be improved by a lubricating transfer film formed by released CDs. This novel strategy for slow-release application is valuable for drug delivery and bio-tribology.

  5. Effect of preparation methods and doping on the structural and tunable emissions of CdS

    NASA Astrophysics Data System (ADS)

    Mohamed, Mohamed Bakr; Abdel-Kader, M. H.; Alhazime, Ali A.; Almarashi, Jamal Q. M.

    2018-03-01

    Fe, Mn and Mg doped CdS samples were prepared by thermolysis method in air and under flow of nitrogen. Structural, compositional and optical properties of the prepared samples were investigated using x-ray powder diffraction (XRD), scanning electron microscope (SEM/EDS mapping), Fourier transform infrared red (FTIR), UV-vis absorption and photoluminescence (PL) spectroscopes. Rietveld refinement of x-ray data showed that all the undoped and doped CdS samples prepared in air and under flow of nitrogen have both cubic and hexagonal structures. The percentages of hexagonal and cubic phases for all prepared samples were determined. The crystallite size increased for CdS prepared under flow of N2 compared with the sample prepared in air. The energy gap of all the samples was calculated using UV data. The intensity of PL emission changed according to the method of preparation and the kind of doping elements. PL emission revealed a blue shift for CdS prepared in air compared with CdS prepared under flow of nitrogen; also all doped samples showed a red shift of PL spectra compared with undoped samples. Undoped and doped CdS with Fe and Mg samples emitted violet and blue sub-spectra. Mn doped CdS prepared in air revealed violet, blue and yellow sub-spectra, while the sample prepared under flow of N2 emitted violet, blue and green sub-spectra.

  6. Combination of counterpropagation artificial neural networks and antioxidant activities for comprehensive evaluation of associated-extraction efficiency of various cyclodextrins in the traditional Chinese formula Xue-Zhi-Ning.

    PubMed

    Sun, Lili; Yang, Jianwen; Wang, Meng; Zhang, Huijie; Liu, Yanan; Ren, Xiaoliang; Qi, Aidi

    2015-11-10

    Xue-Zhi-Ning (XZN) is a widely used traditional Chinese medicine formula to treat hyperlipidemia. Recently, cyclodextrins (CDs) have been extensively used to minimize problems relative to medicine bioavailability, such as low solubility and poor stability. The objective of this study was to determine the associated-extraction efficiency of various CDs in XZN. Three various type CDs were evaluated, including native CDs (α-CD, β-CD), hydrophilic CD derivatives (HP-β-CD and Me-β-CD), and ionic CD derivatives (SBE-β-CD and CM-β-CD). An ultra high-performance liquid chromatography (UHPLC) fingerprint was applied to determine the components in CD extracts and original aqueous extract (OAE). A counterpropagation artificial neural network (CP-ANN) was used to analyze the components in different extracts and compare the selective extraction of various CDs. Extraction efficiencies of the various CDs in terms of extracted components follow the ranking, ionic CD derivatives>hydrophilic CD derivatives>native CDs>OAE. Besides, different types of CDs have their own selective extraction and ionic CD derivatives present the strongest associated-extraction efficiency. Antioxidant potentials of various extracts were evaluated by determining the inhibition of spontaneous, H2O2-induced, CCl4-induced and Fe(2+)/ascorbic acid-induced lipid peroxidation (LPO) and analyzing the scavenging capacity for DPPH and hydroxyl radicals. The order of extraction efficiencies of the various CDs relative to antioxidant activities is as follows: SBE-β-CD>CM-β-CD>HP-β-CD>Me-β-CD>β-CD>α-CD. It can be demonstrated that all of the CDs studied increase the extraction efficiency and that ionic CD derivatives (SBE-β-CD and CM-β-CD) present the highest extraction capability in terms of amount extracted and antioxidant activities of extracts. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Nitrogen and Phosphorus Co-Doped Carbon Nanodots as a Novel Fluorescent Probe for Highly Sensitive Detection of Fe(3+) in Human Serum and Living Cells.

    PubMed

    Shi, Bingfang; Su, Yubin; Zhang, Liangliang; Huang, Mengjiao; Liu, Rongjun; Zhao, Shulin

    2016-05-04

    Chemical doping with heteroatoms can effectively modulate physicochemical and photochemical properties of carbon dots (CDs). However, the development of multi heteroatoms codoped carbon nanodots is still in its early stage. In this work, a facile hydrothermal synthesis strategy was applied to synthesize multi heteroatoms (nitrogen and phosphorus) codoped carbon nanodots (N,P-CDs) using glucose as carbon source, and ammonia, phosphoric acid as dopant, respectively. Compared with CDs, the multi heteroatoms doped CDs resulted in dramatic improvement in the electronic characteristics and surface chemical activities. Therefore, the N,P-CDs prepared as described above exhibited a strong blue emission and a sensitive response to Fe(3+). The N,P-CDs based fluorescent sensor was then applied to sensitively determine Fe(3+) with a detection limit of 1.8 nM. Notably, the prepared N,P-CDs possessed negligible cytotoxicity, excellent biocompatibility, and high photostability. It was also applied for label-free detection of Fe(3+) in complex biological samples and the fluorescence imaging of intracellular Fe(3+), which indicated its potential applications in clinical diagnosis and other biologically related study.

  8. Morphology, structure and optical properties of hydrothermally synthesized CeO2/CdS nanocomposites

    NASA Astrophysics Data System (ADS)

    Mohanty, Biswajyoti; Nayak, J.

    2018-04-01

    CeO2/CdS nanocomposites were synthesized using a two-step hydrothermal technique. The effects of precursor concentration on the optical and structural properties of the CeO2/CdS nanoparticles were systematically studied. The morphology, composition and the structure of the CeO2/CdS nanocomposite powder were studied by scanning electron microscopy (SEM), energy dispersive X-ray spectrum analysis (EDXA) and X-ray diffraction (XRD), respectively. The optical properties of CeO2/CdS nanocomposites were studied by UV-vis absorption and photoluminescence (PL) spectroscopy. The optical band gaps of the CeO2/CdS nanopowders ranged from 2.34 eV to 2.39 eV as estimated from the UV-vis absorption. In the room temperature photoluminescence spectrum of CeO2/CdS nanopowder, a strong blue emission band was observed at 400 nm. Since the powder shows strong visible luminescence, it may be used as a blue phosphor in future. The original article published with this DOI was submitted in error. The correct article was inadvertently left out of the original submission. This has been rectified and the correct article was published online on 16 April 2018.

  9. Ratiometric, visual, dual-signal fluorescent sensing and imaging of pH/copper ions in real samples based on carbon dots-fluorescein isothiocyanate composites.

    PubMed

    Zhu, Xinxin; Jin, Hui; Gao, Cuili; Gui, Rijun; Wang, Zonghua

    2017-01-01

    In this article, a facile aqueous synthesis of carbon dots (CDs) was developed by using natural kelp as a new carbon source. Through hydrothermal carbonization of kelp juice, fluorescent CDs were prepared and the CDs' surface was modified with polyethylenimine (PEI). The PEI-modified CDs were conjugated with fluorescein isothiocyanate (FITC) to fabricate CDs-FITC composites. To exploit broad applications, the CDs-FITC composites were developed as fluorescent sensing or imaging platforms of pH and Cu 2+ . Analytical performances of the composites-based fluorescence (FL) sensors were evaluated, including visual FL imaging of pH in glass bottle, ratiometric FL sensing of pH in yogurt samples, visual FL latent fingerprint and leaf imaging detection of [Cu 2+ ], dual-signal FL sensing of [Cu 2+ ] in yogurt and human serum samples. Experimental results from ratiometric, visual, dual-signal FL sensing and imaging applications confirmed the high feasibility, accuracy, stabilization and simplicity of CDs-FITC composites-based FL sensors for the detection of pH and Cu 2+ ions in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Quantum dots coupled ZnO nanowire-array panels and their photocatalytic activities.

    PubMed

    Liao, Yulong; Que, Wenxiu; Zhang, Jin; Zhong, Peng; Yuan, Yuan; Qiu, Xinku; Shen, Fengyu

    2013-02-01

    Fabrication and characterization of a heterojunction structured by CdS quantum dots@ZnO nanowire-array panels were presented. Firstly, ZnO nanowire-array panels were prepared by using a chemical bath deposition approach where wurtzite ZnO nanowires with a diameter of about 100 nm and 3 microm in length grew perpendicularly to glass substrate. Secondly, CdS quantum dots were deposited onto the surface of the ZnO nanowire-arrays by using successive ion layer absorption and reaction method, and the CdS shell/ZnO core heterojunction were thus obtained. Field emission scanning electron microscopy and transmission electron microscope were employed to characterize the morphological properties of the as-obtained CdS quantum dots@ZnO nanowire-array panels. X-ray diffraction was adopted to characterize the crystalline properties of the as-obtained CdS quantum dots@ZnO nanowire-array panels. Methyl orange was taken as a model compound to confirm the photocatalytic activities of the CdS shell/ZnO core heterojunction. Results indicate that CdS with narrow band gap not only acts as a visible-light sensitizer but also is responsible for an effective charge separation.

  11. Enhanced photocatalytic activity of graphitic carbon nitride/cadmium sulfide heterojunctions by protonating treatment

    NASA Astrophysics Data System (ADS)

    Yan, Mengdie; Ma, Yushuang; Zhang, Huanhuan; Ye, Boyong; Dong, Xiaoping

    2018-05-01

    Highly efficient visible-light-driven protonated g-C3N4 (pg-C3N4)/CdS heterojunctions with different weight ratios of CdS were prepared by treating g-C3N4 with hydrochloric acid and using an in-situ precipitation method. The structure and morphology of heterojunctions were investigated by X-ray powder diffraction (XRD), transmission electron microscopy (TEM), UV-vis diffuse reflectance spectroscopy (DRS), Fourier transform infrared spectroscopy (FTIR) and nitrogen adsorption technology. The as-prepared pg-C3N4/CdS heterojunction with 50 wt% of g-C3N4 exhibited much higher photocatalytic activity for photodegradation of methyl orange (MO) than pg-C3N4, CdS and g-C3N4/CdS without protonation as well, which could be contributed to the activation of hydrochloric acid treatment and the improved electron-hole separation due to their overlapping band structure of CdS and pg-C3N4. A possible photocatalytic mechanism of the pg-C3N4/CdS heterojunctions with superoxide radical species as the main active species in photocatalysis was proposed on the basis of experimental results.

  12. Novel optical properties of CdS:Zn rocksalt system (a theoretical study)

    NASA Astrophysics Data System (ADS)

    Khan, M. Junaid Iqbal; Nauman Usmani, M.; Kanwal, Zarfishan

    2017-11-01

    In present computational study, we focus on optical properties of Zn doped CdS for 1  ×  1  ×  2 and 2  ×  2  ×  2 supercell configurations. Cd atoms are substituted with Zn atoms and results for optical properties demonstrate different trends due to interaction of Zn with S atoms. The study has been performed by PBE-GGA approach using Wien2K within framework of DFT. TDOS and PDOS represent that S-3p states are responsible for conduction. For large supercell configuration, a tremendous change in optical properties has been observed due to different bonding. Optical absorption tends to increase in visible range which supports candidacy of Zn doped CdS for enhanced optoelectronic and nanotechnology applications.

  13. PVP capped CdS nanoparticles for UV-LED applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivaram, H.; Selvakumar, D.; Jayavel, R., E-mail: rjvel@annauniv.edu

    Polyvinlypyrrolidone (PVP) capped cadmium sulphide (CdS) nanoparticles are synthesized by wet chemical method. The powder X-ray diffraction (XRD) result indicates that the nanoparticles are crystallized in cubic phase. The optical properties are characterized by UV-Vis absorption. The morphology of CdS nanoparticles are studied using Scanning electron microscope (SEM). The thermal behavior of the as prepared nanoparticles has been examined by Thermo gravimetric analysis (TGA). The optical absorption study of pvp capped CdS reveal a red shift confirms the UV-LED applications.

  14. Health Care Expenditures and Utilization for Children With Noncomplex Chronic Disease.

    PubMed

    Hoefgen, Erik R; Andrews, Annie L; Richardson, Troy; Hall, Matthew; Neff, John M; Macy, Michelle L; Bettenhausen, Jessica L; Shah, Samir S; Auger, Katherine A

    2017-09-01

    Pediatric health care expenditures and use vary by level of complexity and chronic illness. We sought to determine expenditures and use for children with noncomplex chronic diseases (NC-CDs). We performed a retrospective, cross-sectional analysis of Medicaid enrollees (ages 0-18 years) from January 1, 2012, through December 31, 2013, using administrative claims (the Truven MarketScan Medicaid Database). Patients were categorized by chronicity of illness by using 3M Health Information System's Clinical Risk Groups (CRGs) as follows: without chronic diseases (WO-CDs) (CRG 1-2), NC-CDs (CRG 3-5), and complex chronic diseases (C-CDs) (CRG 6-9). Primary outcomes were medical expenditures, including total annualized population expenditure and per-member per-year expenditure (PMPY). Secondary outcomes included the number of health care encounters over the 2-year period. There were 2 424 946 children who met inclusion criteria, 53% were WO-CD; 36% had an NC-CD; and 11% had a C-CD. Children with NC-CDs accounted for 33% ($2801 PMPY) of the annual spending compared with 20% ($1151 PMPY) accounted for by children WO-CDs and 47% ($12 569 PMPY) by children with C-CDs. The median outpatient visit count by group over the 2-year period was 15 (interquartile range [IQR] 10-25) for NC-CD, 8 (IQR 5-13) WO-CD, and 34 (IQR 19-72) for C-CD. Children with NC-CDs accounted for 33% of pediatric Medicaid expenditures and have significantly higher PMPY and aggregate annual expenditures than children WO-CDs. The annual aggregate expenditures of the NC-CD group represent a significant societal cost because of the high volume of children, extrapolated to ∼$34.9 billion annually in national Medicaid expenditures. Copyright © 2017 by the American Academy of Pediatrics.

  15. Exciton-Plasmon Interaction between AuNPs/Graphene Nanohybrids and CdS Quantum Dots/TiO2 for Photoelectrochemical Aptasensing of Prostate-Specific Antigen.

    PubMed

    Cai, Guoneng; Yu, Zhengzhong; Ren, Rongrong; Tang, Dianping

    2018-03-23

    A competitive-displacement reaction strategy based on target-induced dissociation of gold nanoparticle coated graphene nanosheet (AuNPs/GN) from CdS quantum dot functionalized mesoporous titanium dioxide (CdS QDs/TiO 2 ) was designed for the sensitive photoelectrochemical (PEC) aptasensing of prostate-specific antigen (PSA) through the exciton-plasmon interaction (EPI) between CdS QDs and AuNPs. To construct such an aptasensing system, capture DNA was initially conjugated covalently onto CdS QDs/TiO 2 -modified electrode, and then AuNPs/GN-labeled PSA aptamer was bound onto biofunctionalized CdS QDs/TiO 2 via hybridization chain reaction of partial bases with capture DNA. Introduction of AuNPs/GN efficiently quenched the photocurrent of CdS QDs/TiO 2 thanks to energy transfer. Upon addition of target PSA, the sandwiched aptamer between CdS QDs/TiO 2 and AuNPs/GN reacted with the analyte analyte, thus resulting in the dissociation of AuNPs/GN from the CdS QDs/TiO 2 to increase the photocurrent. Under optimum conditions, the aptasensing platform exhibited a high sensitivity for PSA detection within a dynamic linear range of 1.0 pg/mL to 8.0 ng/mL at a low limitat of detection of 0.52 pg/mL. The interparticle distance of exciton-plasmon interaction and contents of AuNPs corresponding to EPI effect in this system were also studied. Good selectivity and high reproducibility were obtained for the analysis of target PSA. Importantly, the accuracy and matrix effect of PEC aptasensor was evaluated for the determination of human serum specimens and newborn calf serum-diluted PSA standards, giving a well-matched result with the referenced PSA ELISA kit.

  16. Amorphous MoS{sub x} on CdS nanorods for highly efficient photocatalytic hydrogen evolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xiaofang; Tang, Chaowan; Zheng, Qun

    Loading cocatalyst on semiconductors was crucially necessary for improving the photocatalytic hydrogen evolution. Amorphous MoS{sub x} as a novel and noble metal-free cocatalyst was loaded on CdS nanorods by a simple photodeposition method. Efficient hydrogen evolution with amount of 15 mmol h{sup −1} g{sup −1} was observed over the MoS{sub x} modified CdS nanorods, which was about 6 times higher than that by using Pt as cocatalyst. Meanwhile, with MoS{sub x} cocatalyst, the efficiency of CdS nanorods was superior to that of CdS nanoparticles and bulk CdS. No deactivation could be observed in the efficiency of MoS{sub x} modified CdSmore » nanorods under irradiation for successive 10 h. Further experimental results indicated that the efficient electrons transfer, low overpotential of hydrogen evolution and active S atoms over the MoS{sub x} modified CdS nanorods were responsible for the higher efficiency. Our results provided guidance for synthesizing noble metal-free materials as cocatalyst for photocatalytic hydrogen evolution. - Graphical abstract: Photodeposition of amorphous MoS{sub x} on CdS nanorods for highly efficient photocatalytic hydrogen evolution. - Highlights: • Amorphous MoSx cocatalyst was loaded on CdS NRs by a simple photodeposition. • MoS{sub x}/CdS NRs exhibited 6 times higher hydrogen evolution efficiency than Pt/CdS NRs. • The hydrogen evolution of MoS{sub x}/CdS NRs linearly increased with prolonging time. • Lower overpotential and efficient electron transfer were observed over MoS{sub x}/CdS NRs.« less

  17. Photocatalyst based on TiO2 nanotube arrays co-decorated with CdS quantum dots and reduced graphene oxide irradiated by γ rays for effective degradation of ethylene

    NASA Astrophysics Data System (ADS)

    Zhang, Quan; Ye, Shengying; Song, Xianliang; Luo, Shucan

    2018-06-01

    We report herein a means of transforming TiO2 nanotube arrays (TNAs) from an amorphous state to an anatase crystal state (denoted as ∗TNAs), and present a single-step synthetic route for preparing CdS quantum dots (CdS QDs) as well as reduced graphene oxide (rGO) through gamma-ray irradiation. The as-prepared ∗TNAs, CdS QDs, and rGO, which had all been subjected to gamma-ray irradiation, were then assembled together to produce the desired heterojunction (denoted as CdS QDs/rGO-∗TNAs). X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), ultraviolet/visible diffuse-reflectance spectroscopy (UV/Vis DRS), Fourier-transform infrared spectroscopy (FTIR), micro-Raman spectrometry (RS), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS) have been applied to characterize the appearance and performance of this photocatalyst. The photocatalytic activity of CdS QDs/rGO-∗TNAs towards ethylene degradation has been measured by placing it in a simulated cold-storage environment, the temperature and humidity of which were set at about 3 ± 1 °C and 75-90%, respectively. The results showed that the rate constant (K) of ethylene degradation could reach up to 1.07 × 10-3 min-1 with CdS QDs/rGO-∗TNAs, as compared to 2.30 × 10-4 min-1 with ∗TNAs and 6.25 × 10-4 min-1 with CdS QDs-∗TNAs, indicating that the constructed CdS QDs/rGO-∗TNAs constitutes a promising photocatalyst for ethylene removal in a cold storage environment.

  18. Scalable alignment of CdS nanowires based on efficient roll-on transfer technique.

    PubMed

    Yan, Shancheng; Shi, Yi; Xiao, Zhongdang; Wang, Junzhuan; Hu, Dong; Xul, Xin; Lu, Tao; Liu, Aili; Gao, Fan

    2013-06-01

    A roll-on transfer strategy is developed to enable large-scale and uniform assembly of CdS nanowires on various rigid and flexible substrate materials. In this method, the CdS nanowires were synthesized by the hydrothermal method. The dispersed CdS NWs could be firstly aligned and selectively deposited at the micro/nanochannels between aligned nanofibers on the surface of the donor roller as a result of evaporation-induced flow and capillary action, and then the directional and aligned transfer of the CdS NWs from the donor roller to a receiver substrate via roll-on transfer technique. Finally, a device structures consisting of the nanowire channel and two metal electrodes was fabricated. The electrical property of this device was observed.

  19. One-step, low-temperature fabrication of CdS quantum dots by watermelon rind: a green approach

    PubMed Central

    Lakshmipathy, Rajasekhar; Sarada, Nallani Chakravarthula; Chidambaram, K; Pasha, Sk Khadeer

    2015-01-01

    We investigated the one-step synthesis of CdS nanoparticles via green synthesis that used aqueous extract of watermelon rind as a capping and stabilizing agent. Preliminary phytochemical analysis depicted the presence of carbohydrates which can act as capping and stabilizing agents. Synthesized CdS nanoparticles were characterized using UV-visible, Fourier transform infrared spectroscopy, X-ray diffraction, EDX, dynamic light scattering, transmission electron microscopy, and atomic force microscopy techniques. The CdS nanoparticles were found to be size- and shape-controlled and were stable even after 3 months of synthesis. The results suggest that watermelon rind, an agro-waste, can be used for synthesis of CdS nanoparticles without any addition of stabilizing and capping agents. PMID:26491319

  20. Enhanced photoelectrochemical properties of TiO2 nanorod arrays decorated with CdS nanoparticles

    PubMed Central

    Xie, Zheng; Liu, Xiangxuan; Wang, Weipeng; Liu, Can; Li, Zhengcao; Zhang, Zhengjun

    2014-01-01

    TiO2 nanorod arrays (TiO2 NRAs) sensitized with CdS nanoparticles were fabricated via successive ion layer adsorption and reaction (SILAR), and TiO2 NRAs were obtained by oxidizing Ti NRAs obtained through oblique angle deposition. The TiO2 NRAs decorated with CdS nanoparticles exhibited excellent photoelectrochemical and photocatalytic properties under visible light, and the one decorated with 20 SILAR cycles CdS nanoparticles shows the best performance. This can be attributed to the enhanced separation of electrons and holes by forming heterojunctions of CdS nanoparticles and TiO2 NRAs. This provides a promising way to fabricate the material for solar energy conversion and wastewater degradation. PMID:27877718

  1. Development of a Higher Fidelity Model for the Cascade Distillation Subsystem (CDS)

    NASA Technical Reports Server (NTRS)

    Perry, Bruce; Anderson, Molly

    2014-01-01

    Significant improvements have been made to the ACM model of the CDS, enabling accurate predictions of dynamic operations with fewer assumptions. The model has been utilized to predict how CDS performance would be impacted by changing operating parameters, revealing performance trade-offs and possibilities for improvement. CDS efficiency is driven by the THP coefficient of performance, which in turn is dependent on heat transfer within the system. Based on the remaining limitations of the simulation, priorities for further model development include: center dot Relaxing the assumption of total condensation center dot Incorporating dynamic simulation capability for the buildup of dissolved inert gasses in condensers center dot Examining CDS operation with more complex feeds center dot Extending heat transfer analysis to all surfaces

  2. Structural and photoluminescence properties of Ni doped CdS nanoparticles synthesis by sol gel method

    NASA Astrophysics Data System (ADS)

    Mahdi, Hadeel Salih; Parveen, Azra; Azam, Ameer

    2018-05-01

    Ni doped CdS nanoparticles have been successfully synthesized by sol-gel method. Nickel nitrate, cadmium nitrate, sodium sulfide has been used as precursors for the preparation of these Ni-doped CdS nanoparticles. The structural properties were studied by X-ray diffraction analysis. Surface morphology and the composition of the samples were studied by scanning electron microscope (SEM). The X-ray diffraction results revealed that the Ni-doped CdS nanoparticles were in hexagonal structure. The crystallite size was determined from Debye-Scherer equation and showed that the particle size increases with the doping of Ni. Optical absorption spectra of Ni doped CdS also was studied by Photoluminescence spectroscopy in the range of 200-600 nm.

  3. Synthesis of Nitrogen and Sulfur Co-doped Carbon Dots from Garlic for Selective Detection of Fe3+

    NASA Astrophysics Data System (ADS)

    Sun, Chun; Zhang, Yu; Wang, Peng; Yang, Yue; Wang, Yu; Xu, Jian; Wang, Yiding; Yu, William W.

    2016-02-01

    Garlic was used as a green source to synthesize carbon dots (CDs) with a systematic study of the optical and structure properties. Ethylenediamine was added into the synthesis to improve the photoluminescence quantum yield (PL QY) of the CDs. Detailed structural and composition studies demonstrated that the content of N and the formation of C-N and C=N were critical to improve the PL QY. The as-synthesized CDs exhibited excellent stability in a wide pH range and high NaCl concentrations, rendering them applicable in complicated and harsh conditions. Quenching the fluorescence of the CDs in the presence of Fe3+ ion made these CDs a luminescent probe for selective detection of Fe3+ ion.

  4. Synthesis of Nitrogen and Sulfur Co-doped Carbon Dots from Garlic for Selective Detection of Fe(3.).

    PubMed

    Sun, Chun; Zhang, Yu; Wang, Peng; Yang, Yue; Wang, Yu; Xu, Jian; Wang, Yiding; Yu, William W

    2016-12-01

    Garlic was used as a green source to synthesize carbon dots (CDs) with a systematic study of the optical and structure properties. Ethylenediamine was added into the synthesis to improve the photoluminescence quantum yield (PL QY) of the CDs. Detailed structural and composition studies demonstrated that the content of N and the formation of C-N and C=N were critical to improve the PL QY. The as-synthesized CDs exhibited excellent stability in a wide pH range and high NaCl concentrations, rendering them applicable in complicated and harsh conditions. Quenching the fluorescence of the CDs in the presence of Fe(3+) ion made these CDs a luminescent probe for selective detection of Fe(3+) ion.

  5. Nanobiotechnology of Carbon Dots: A Review.

    PubMed

    Durán, Nelson; Simões, Mateus B; de Moraes, Ana C M; Fávaro, Wagner J; Seabra, Amedea B

    2016-07-01

    In recent years, carbon dots (CDs) have gained increasing attention owing to their unique properties and enormous potential for several biomedical and technological applications. CDs are biocompatible, have a small size with a relatively large surface area, are photostable, and have customizable photoluminescence properties. This review is divided into the following discussions of CDs: general definitions; an overview of recent reviews; methods of green and classical synthesis; applications in bioimaging, involving supercapacitors, nanocarriers and nanomedicine; toxicological evaluations (including cytotoxic, genotoxic and anti-cancer properties of CDs); their conjugation with enzymes, biosensors, and cell labeling. Finally the remaining drawbacks and challenges of CD applications are highlighted. In this context, this article aims to provide critical insight and inspire further developments in the synthesis and application of CDs.

  6. Adaptability of optimization concept in the context of cryogenic distribution for superconducting magnets of fusion machine

    NASA Astrophysics Data System (ADS)

    Sarkar, Biswanath; Bhattacharya, Ritendra Nath; Vaghela, Hitensinh; Shah, Nitin Dineshkumar; Choukekar, Ketan; Badgujar, Satish

    2012-06-01

    Cryogenic distribution system (CDS) plays a vital role for reliable operation of largescale fusion machines in a Tokamak configuration. Managing dynamic heat loads from the superconducting magnets, namely, toroidal field, poloidal field, central solenoid and supporting structure is the most important function of the CDS along with the static heat loads. Two concepts are foreseen for the configuration of the CDS: singular distribution and collective distribution. In the first concept, each magnet is assigned with one distribution box having its own sub-cooler bath. In the collective concept, it is possible to share one common bath for more than one magnet system. The case study has been performed with an identical dynamic heat load profile applied to both concepts in the same time domain. The choices of a combined system from the magnets are also part of the study without compromising the system functionality. Process modeling and detailed simulations have been performed for both the options using Aspen HYSYS®. Multiple plasma pulses per day have been considered to verify the residual energy deposited in the superconducting magnets at the end of the plasma pulse. Preliminary 3D modeling using CATIA® has been performed along with the first level of component sizing.

  7. A tale of two hospitals: assessing cultural landscapes and compositions.

    PubMed

    Braithwaite, Jeffrey; Westbrook, Mary T; Iedema, Rick; Mallock, Nadine A; Forsyth, Rowena; Zhang, Kai

    2005-03-01

    Clinical directorate service structures (CDs) have been widely implemented in acute settings in the belief that they will enhance efficiency and patient care by bringing teams together and involving clinicians in management. We argue that the achievement of such goals depends not only on changing its formalized structural arrangements but also the culture of the organisation concerned. We conducted comparative observational studies and questionnaire surveys of two large Australian teaching hospitals similar in size, role and CD structure. Martin's conceptualization of culture in terms of integration, differentiation and fragmentation was applied in the analysis of the data. The ethnographic work revealed that compared to Metropolitan Hospital, Royal Hospital was better supported and more favourably viewed by its staff across six categories identified in both settings: leadership, structure, communication, change, finance and human resource management. Royal staff were more optimistic about their organisation's ability to meet future challenges. The surveys revealed that both staff groups preferred CD to traditional structures and shared some favourable and critical views of them. However Royal staff were significantly more positive, reporting many more benefits from CDs e.g. improved working relations, greater accountability and efficiency, better cost management, more devolvement of management to clinicians and a hospital more strategically placed and patient focused. Metropolitan staff were more likely to claim that CDs failed to solve problems and created a range of others including disunity and poor working relationships. There was greater consensus of views among Royal staff and more fragmentation at Metropolitan where both intensely held and uncertain attitudes were more common. The outcomes of implementing CDs in these two similar organisations differed considerably indicating the need to address cultural issues when introducing structural change. Martin's framework provides a useful antidote to researchers' tendency to focus at only one level of culture.

  8. Tuning band alignment by CdS layers using a SILAR method to enhance TiO2/CdS/CdSe quantum-dot solar-cell performance.

    PubMed

    Zhang, Bingkai; Zheng, Jiaxin; Li, Xiaoning; Fang, Yanyan; Wang, Lin-Wang; Lin, Yuan; Pan, Feng

    2016-04-28

    We report tuning band alignment by optimized CdS layers using a SILAR method to achieve the recorded best performance with about 6% PCE in TiO2/CdS/CdSe QDSSCs. Combining experimental and theoretical studies, we find that a better lattices match between CdS and TiO2 assists the growth of CdSe, and the combined effect of charge transfer and surface dipole moment at the TiO2/CdS/CdSe interface shifts the energy levels of TiO2 upward and increases Voc of the solar cells. More importantly, the band gap of CdS buffer layers is sensitive to the distortion induced by lattice mismatch and numbers of CdS layers. For example, the barrier for charge transfer disappears when there are more than 4 layers of CdS, facilitating the charge injection from CdSe to TiO2.

  9. Psychometric Properties of the Persian Version of Care Dependency Scale in Nursing Homes.

    PubMed

    Rajabi, Gholamreza; Namadmalan, Masoume; Dijkstra, Ate; Ghasemzade, Roya; Foroughan, Mahshid; Zahednejad, Shahla

    The purpose of the study was to examine the psychometric properties of the Persian version of the Care Dependency Scale (CDS) in nursing homes. Instrument development. The English version of the CDS was translated into Persian. A convenience sample of 140 (100 older people without dementia and 40 patients with dementia) Persian-speaking people were selected from the nursing homes in Ahvaz, Iran. Cronbach's alpha, discriminant validity, and construct validity (exploratory factor analysis) were examined. Exploratory factor analysis indicated that the CDS has two factors, including psychosocial and somatic factors. Discriminant validity showed that the CDS can differentiate patients with dementia from the older adults without dementia. The results of the study showed that the Persian CDS is a reliable and valid scale when used in nursing homes. The Persian version of the CDS can help clinicians and nurses to assess patients' need and the degree of care dependency among older adults in Persian-speaking areas.

  10. Engineering iodine-doped carbon dots as dual-modal probes for fluorescence and X-ray CT imaging.

    PubMed

    Zhang, Miaomiao; Ju, Huixiang; Zhang, Li; Sun, Mingzhong; Zhou, Zhongwei; Dai, Zhenyu; Zhang, Lirong; Gong, Aihua; Wu, Chaoyao; Du, Fengyi

    2015-01-01

    X-ray computed tomography (CT) is the most commonly used imaging technique for noninvasive diagnosis of disease. In order to improve tissue specificity and prevent adverse effects, we report the design and synthesis of iodine-doped carbon dots (I-doped CDs) as efficient CT contrast agents and fluorescence probe by a facile bottom-up hydrothermal carbonization process. The as-prepared I-doped CDs are monodispersed spherical nanoparticles (a diameter of ~2.7 nm) with favorable dispersibility and colloidal stability in water. The aqueous solution of I-doped CDs showed wavelength-dependent excitation and stable photoluminescence similar to traditional carbon quantum dots. Importantly, I-doped CDs displayed superior X-ray attenuation properties in vitro and excellent biocompatibility. After intravenous injection, I-doped CDs were distributed throughout the body and excreted by renal clearance. These findings validated that I-doped CDs with high X-ray attenuation potency and favorable photoluminescence show great promise for biomedical research and disease diagnosis.

  11. Engineering iodine-doped carbon dots as dual-modal probes for fluorescence and X-ray CT imaging

    PubMed Central

    Zhang, Miaomiao; Ju, Huixiang; Zhang, Li; Sun, Mingzhong; Zhou, Zhongwei; Dai, Zhenyu; Zhang, Lirong; Gong, Aihua; Wu, Chaoyao; Du, Fengyi

    2015-01-01

    X-ray computed tomography (CT) is the most commonly used imaging technique for noninvasive diagnosis of disease. In order to improve tissue specificity and prevent adverse effects, we report the design and synthesis of iodine-doped carbon dots (I-doped CDs) as efficient CT contrast agents and fluorescence probe by a facile bottom-up hydrothermal carbonization process. The as-prepared I-doped CDs are monodispersed spherical nanoparticles (a diameter of ~2.7 nm) with favorable dispersibility and colloidal stability in water. The aqueous solution of I-doped CDs showed wavelength-dependent excitation and stable photoluminescence similar to traditional carbon quantum dots. Importantly, I-doped CDs displayed superior X-ray attenuation properties in vitro and excellent biocompatibility. After intravenous injection, I-doped CDs were distributed throughout the body and excreted by renal clearance. These findings validated that I-doped CDs with high X-ray attenuation potency and favorable photoluminescence show great promise for biomedical research and disease diagnosis. PMID:26609232

  12. Template-free solution approach to synthesize CdS dendrites with SCN based ionic liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Kangfeng; Li, Jiajia; Cheng, Xianyi

    2011-07-15

    Highlights: {yields} Template-free solution approach to synthesize CdS hierarchical dendrites. {yields} The 1-butyl-3-methlyimidazole thiocyanate ([BMIM][SCN]) plays doubly functional roles in the progress. {yields} The CdS hierarchical dendrites exhibit a more intense emission at 710 nm belongs to infrared band. -- Abstract: Cadmium sulfide dendrites were synthesized by a facile hydrothermal treatment from CdCl{sub 2} and ionic liquid 1-butyl-3-methlyimidazole thiocyanate acted both as sulfur source and surfactant. The product was characterized by means of X-ray powder diffraction and scanning electron microscopy. X-ray powder diffraction studies indicated that the product was well-crystallized hexagonal phase of CdS, and the scanning electron microscopy imagesmore » showed that the obtained powders consisted of a wealth of well-defined CdS dendritic microstructures with a pronounced trunk and highly ordered branches. The UV-Vis and photoluminescence spectroscopy measurements were taken as well. The possible formation mechanism of CdS dendrites was simply proposed in the end.« less

  13. Prominence of fusion temperature and engineering heteroatoms on multifarious emissive shifts in carbon dots.

    PubMed

    Velusamy, Jayaramakrishnan; Ramos-Ortiz, Gabriel; Rodríguez, Mario; Hernández-Cruz, Olivia; Ponce, Arturo

    2018-05-16

    We present a simple but robust strategy to engineering heteroatoms (N, S) on carbon dots (CDs) surface that results in a collection of enhanced photoluminescence (PL) emissions. The use of citric acid (CA) and 2-Imidazolidinethione (2-IZT) as precursors was envisioned to study the impact of thermolysis process on the PL properties. The proposed strategy, implemented at two different temperatures (180 °C and 200 °C), is suitable to produce CDs with tunable PL and quantum yield (QY) up to ∼32%. Similar to earlier reports of CA-based CDs, the self-assembling of fluorophores integrated into the CDs edge is hypothesized, however, in our CDs a double intriguing effect of blue- and red-shifting can be observed for PL as the wavelength of excitation is increased in the range 280-480 nm. Through a comprehensive characterization and evaluation of these CDs in water suspensions, the mechanisms that lead to PL multifarious emissions are proposed. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Photochemical Fabrication of Transition Metal Nanoparticles Using CdS Template and Their Co-Catalysis Effects for TiO2 Photocatalysis

    NASA Astrophysics Data System (ADS)

    Badhwar, Nidhi; Gupta, Nidhi; Pal, Bonamali

    2013-09-01

    Transition metal nanoparticles were prepared by chemical dissolution of CdS template from metal photodeposited CdS nanorod (length = 70-85 nm and width = 5-6 nm) heterocomposites. Size (9-10 nm) of metal nanoparticles obtained after CdS removal was larger than the size (4-6 nm) of metal nanodeposits over CdS template. The obtained Au nanoparticles displayed a broad red shifted absorption band at 660 nm, whereas Pt, Pd and Rh nanoparticles exhibit featureless absorption spectra. Elemental analysis confirms the complete removal of CdS template from Au-CdS (Au — 2.65 at.%) and Ag-CdS (Ag — 2.06 at.%) composites showing no Cd peak. These metal nanoparticles imparted dissimilar co-catalytic activity of TiO2 for photocatalytic degradation of salicylic acid in the order Au > Pt > Pd > Ag > Rh as a function of their nature, electronegativity, redox potential and work function.

  15. Highly Efficient Red-Emitting Carbon Dots with Gram-Scale Yield for Bioimaging.

    PubMed

    Ding, Hui; Wei, Ji-Shi; Zhong, Ning; Gao, Qing-Yu; Xiong, Huan-Ming

    2017-11-07

    Carbon dots (CDs) are a new class of photoluminescent (PL), biocompatible, environment-friendly, and low-cost carbon nanomaterials. Synthesis of highly efficient red-emitting carbon dots (R-CDs) on a gram scale is a great challenge at present, which heavily restricts the wide applications of CDs in the bioimaging field. Herein, R-CDs with a high quantum yield (QY) of 53% are produced on a gram scale by heating a formamide solution of citric acid and ethylenediamine. The as-prepared R-CDs have an average size of 4.1 nm and a nitrogen content of about 30%, with an excitation-independent emission at 627 nm. After detailed characterizations, such strong red fluorescence is ascribed to the contribution from the nitrogen- and oxygen-related surface states and the nitrogen-derived structures in the R-CD cores. Our R-CDs show good photostability and low cytotoxicity, and thus they are excellent red fluorescence probes for bioimaging both in vitro and in vivo.

  16. Carbon dot/polyvinylpyrrolidone hybrid nanofibers with efficient solid-state photoluminescence constructed using an electrospinning technique

    NASA Astrophysics Data System (ADS)

    Zhai, Yue; Bai, Xue; Cui, Haining; Zhu, Jinyang; Liu, Wei; Zhang, Tianxiang; Dong, Biao; Pan, Gencai; Xu, Lin; Zhang, Shuang; Song, Hongwei

    2018-01-01

    Carbon dots (CDs) are the promising candidates for application in optoelectronic and biological areas due to their excellent photostability, unique photoluminescence, good biocompatibility, low toxicity and chemical inertness. However, the self-quenching of photoluminescence as they are dried into the solid state dramatically limits their further application. Therefore, realizing efficient photoluminescence and large-scale production of CDs in the solid state is an urgent challenge. Herein, solid-state hybrid nanofibers based on CDs and polyvinylpyrrolidone (PVP) are constructed through an electrospinning process. The resulting solid-state hybrid PVP/CD nanofibers present much enhanced photoluminescence performance compared to the corresponding pristine colloidal CDs due to the decrease in non-radiative recombination of electron-holes. Owing to the suppressed self-quenching of CDs, the photoluminescence quantum yield is considerably improved from 42.9% of pristine CDs to 83.5% of nanofibers under the excitation wavelength of 360 nm. This has great application potential in optical or optoelectronic devices.

  17. Cultivating Fluorescent Flowers with Highly Luminescent Carbon Dots Fabricated by a Double Passivation Method

    PubMed Central

    Chang, Tao; Zhao, Haiping; Du, Huanhuan; Liu, Shan; Wu, Baoshuang; Qin, Shenjun

    2017-01-01

    In this work, we present the fabrication of highly luminescent carbon dots (CDs) by a double passivation method with the assistance of Ca(OH)2. In the reaction process, Ca2+ protects the active functional groups from overconsumption during dehydration and carbonization, and the electron-withdrawing groups on the CD surface are converted to electron-donating groups by the hydroxyl ions. As a result, the fluorescence quantum yield of the CDs was found to increase with increasing Ca(OH)2 content in the reaction process. A blue-shift optical spectrum of the CDs was also found with increasing Ca(OH)2 content, which could be attributed to the increasing of the energy gaps for the CDs. The highly photoluminescent CDs obtained (quantum yield: 86%) were used to cultivate fluorescent carnations by a water culture method, while the results of fluorescence microscopy analysis indicated that the CDs had entered the plant tissue structure. PMID:28686178

  18. Mesoporous structured MIPs@CDs fluorescence sensor for highly sensitive detection of TNT.

    PubMed

    Xu, Shoufang; Lu, Hongzhi

    2016-11-15

    A facile strategy was developed to prepare mesoporous structured molecularly imprinted polymers capped carbon dots (M-MIPs@CDs) fluorescence sensor for highly sensitive and selective determination of TNT. The strategy using amino-CDs directly as "functional monomer" for imprinting simplify the imprinting process and provide well recognition sites accessibility. The as-prepared M-MIPs@CDs sensor, using periodic mesoporous silica as imprinting matrix, and amino-CDs directly as "functional monomer", exhibited excellent selectivity and sensitivity toward TNT with detection limit of 17nM. The recycling process was sustainable for 10 times without obvious efficiency decrease. The feasibility of the developed method in real samples was successfully evaluated through the analysis of TNT in soil and water samples with satisfactory recoveries of 88.6-95.7%. The method proposed in this work was proved to be a convenient and practical way to prepare high sensitive and selective fluorescence MIPs@CDs sensors. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Synthesis and spectral studies on Cd(II) dithiocarbamate complexes and their use as precursors for CdS nanoparticles

    NASA Astrophysics Data System (ADS)

    Sathiyaraj, Ethiraj; Padmavathy, Krishnaraj; Kumar, Chandran Udhaya; Krishnan, Kannan Gokula; Ramalingan, Chennan

    2017-11-01

    Bis(N-cyclopropyl-N-4-chlorobenzyldithiocarbamato-S,S‧)cadmium(II) (1) and (2,2‧-bipyridine) bis(N-cyclopropyl-N-4-chlorobenzyldithiocarbamato-S,S‧)cadmium(II) (2) have been synthesized and characterized by FT-IR, 1HNMR and 13C NMR analyses. For the complex 2, single crystal X-ray diffraction analysis and computational studies (optimized geometry, HOMO-LUMO and MEP) have been executed employing DFT/B3LYP method with LANL 2DZ basic set. The optimized bond lengths and bond angles agree well with the experimental results. The complexes 1 and 2 have been used as single source precursors for the synthesis of ethyleneglycol capped CdS1 and CdS2 nanoparticles, respectively. CdS1 and CdS2 nanoparticles have been synthesized by solvothermal method. PXRD, SEM, Elemental colour mapping, EDAX, TEM and UV-Vis spectroscopy have been used to characterize the as-prepared CdS nanoparticles. The X-ray diffraction pattern confirms both their hexagonal structures.

  20. Why credit risk markets are predestined for exhibiting log-periodic power law structures

    NASA Astrophysics Data System (ADS)

    Wosnitza, Jan Henrik; Leker, Jens

    2014-01-01

    Recent research has established the existence of log-periodic power law (LPPL) patterns in financial institutions’ credit default swap (CDS) spreads. The main purpose of this paper is to clarify why credit risk markets are predestined for exhibiting LPPL structures. To this end, the credit risk prediction of two variants of logistic regression, i.e. polynomial logistic regression (PLR) and kernel logistic regression (KLR), are firstly compared to the standard logistic regression (SLR). In doing so, the question whether the performances of rating systems based on balance sheet ratios can be improved by nonlinear transformations of the explanatory variables is resolved. Building on the result that nonlinear balance sheet ratio transformations hardly improve the SLR’s predictive power in our case, we secondly compare the classification performance of a multivariate SLR to the discriminative powers of probabilities of default derived from three different capital market data, namely bonds, CDSs, and stocks. Benefiting from the prompt inclusion of relevant information, the capital market data in general and CDSs in particular increasingly outperform the SLR while approaching the time of the credit event. Due to the higher classification performances, it seems plausible for creditors to align their investment decisions with capital market-based default indicators, i.e., to imitate the aggregate opinion of the market participants. Since imitation is considered to be the source of LPPL structures in financial time series, it is highly plausible to scan CDS spread developments for LPPL patterns. By establishing LPPL patterns in governmental CDS spread trajectories of some European crisis countries, the LPPL’s application to credit risk markets is extended. This novel piece of evidence further strengthens the claim that credit risk markets are adequate breeding grounds for LPPL patterns.

  1. Advising Medical Students for the Match: A National Survey of Pediatrics Clerkship Directors.

    PubMed

    Ryan, Michael S; Levine, Leonard J; Colbert-Getz, Jorie M; Spector, Nancy D; Fromme, H Barrett

    2015-01-01

    To describe the role and perspectives of pediatrics clerkship directors (CDs) who provide advice to students who apply to Pediatrics residency training programs. We developed a survey based on previous studies and data from the 2012 National Residency Matching Program- Program Director (NRMP-PD) survey. Topics included CDs roles and confidence in advising, perspectives on applicants' competitiveness, and resources used to inform advising practice. This survey was disseminated as part of the 2013 Council on Medical Student Education in Pediatrics annual survey. CDs from 63 (45%) Liaison Committee for Medical Education-accredited medical schools in the United States responded. All CDs had some advising role, and most (68%) served in a formal advising capacity. Most (58%) also participated in the intern selection process at their institution. Those with formal advising roles were not significantly more confident in their advising than those without formal roles. CDs relied heavily on subjective resources and most did not use the NRMP-PD survey data. Despite this, the perspectives of CDs were similar to those of program directors based on the most recent NRMP-PD survey. Pediatrics CDs uniformly serve in advising capacities and have perspectives that compare favorably with those of program directors. Despite this concordance, the high reliance on subjective resources and the frequency in which CDs participate in intern selection raises concern. The results of this study have several implications for key stakeholders in the residency selection process. Copyright © 2015 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  2. Cadmium sulfide quantum dots induce oxidative stress and behavioral impairments in the marine clam Scrobicularia plana.

    PubMed

    Buffet, Pierre-Emmanuel; Zalouk-Vergnoux, Aurore; Poirier, Laurence; Lopes, Christelle; Risso-de-Faverney, Christine; Guibbolini, Marielle; Gilliland, Douglas; Perrein-Ettajani, Hanane; Valsami-Jones, Eugenia; Mouneyrac, Catherine

    2015-07-01

    Cadmium sulfide (CdS) quantum dots have a number of current applications in electronics and solar cells and significant future potential in medicine. The aim of the present study was to examine the toxic effects of CdS quantum dots on the marine clam Scrobicularia plana exposed for 14 d to these nanomaterials (10 µg Cd L(-1) ) in natural seawater and to compare them with soluble Cd. Measurement of labile Cd released from CdS quantum dots showed that 52% of CdS quantum dots remained in the nanoparticulate form. Clams accumulated the same levels of Cd regardless of the form in which it was delivered (soluble Cd vs CdS quantum dots). However, significant changes in biochemical responses were observed in clams exposed to CdS quantum dots compared with soluble Cd. Increased activities of catalase and glutathione-S-transferase were significantly higher in clams exposed in seawater to Cd as the nanoparticulate versus the soluble form, suggesting a specific nano effect. The behavior of S. plana in sediment showed impairments of foot movements only in the case of exposure to CdS quantum dots. The results show that oxidative stress and behavior biomarkers are sensitive predictors of CdS quantum dots toxicity in S. plana. Such responses, appearing well before changes might occur at the population level, demonstrate the usefulness of this model species and type of biomarker in the assessment of nanoparticle contamination in estuarine ecosystems. © 2015 SETAC.

  3. Surface and interface of epitaxial CdTe film on CdS buffered van der Waals mica substrate

    NASA Astrophysics Data System (ADS)

    Yang, Y.-B.; Seewald, L.; Mohanty, Dibyajyoti; Wang, Y.; Zhang, L. H.; Kisslinger, K.; Xie, Weiyu; Shi, J.; Bhat, I.; Zhang, Shengbai; Lu, T.-M.; Wang, G.-C.

    2017-08-01

    Single crystal CdTe films are desirable for optoelectronic device applications. An important strategy of creating films with high crystallinity is through epitaxial growth on a proper single crystal substrate. We report the metalorganic chemical vapor deposition of epitaxial CdTe films on the CdS/mica substrate. The epitaxial CdS film was grown on a mica surface by thermal evaporation. Due to the weak van der Waals forces, epitaxy is achieved despite the very large interface lattice mismatch between CdS and mica (∼21-55%). The surface morphology of mica, CdS and CdTe were quantified by atomic force microscopy. The near surface structures, orientations and texture of CdTe and CdS films were characterized by the unique reflection high-energy electron diffraction surface pole figure technique. The interfaces of CdTe and CdS films and mica were characterized by X-ray pole figure technique and transmission electron microscopy. The out-of-plane and in-plane epitaxy of the heteroepitaxial films stack are determined to be CdTe(111)//CdS(0001)//mica(001) and [1 bar2 1 bar]CdTe//[ 1 bar100]CdS//[010]mica, respectively. The measured photoluminescence (PL), time resolved PL, photoresponse, and Hall mobility of the CdTe/CdS/mica indicate quality films. The use of van der Waals surface to grow epitaxial CdTe/CdS films offers an alternative strategy towards infrared imaging and solar cell applications.

  4. A carbon dot-based "off-on" fluorescent probe for highly selective and sensitive detection of phytic acid.

    PubMed

    Gao, Zhao; Wang, Libing; Su, Rongxin; Huang, Renliang; Qi, Wei; He, Zhimin

    2015-08-15

    We herein report a facile, one-step pyrolysis synthesis of photoluminescent carbon dots (CDs) using citric acid as the carbon source and lysine as the surface passivation reagent. The as-prepared CDs show narrow size distribution, excellent blue fluorescence and good photo-stability and water dispersivity. The fluorescence of the CDs was found to be effectively quenched by ferric (Fe(III)) ions with high selectivity via a photo-induced electron transfer (PET) process. Upon addition of phytic acid (PA) to the CDs/Fe(III) complex dispersion, the fluorescence of the CDs was significantly recovered, arising from the release of Fe(III) ions from the CDs/Fe(III) complex because PA has a higher affinity for Fe(III) ions compared to CDs. Furthermore, we developed an "off-on" fluorescence assay method for the detection of phytic acid using CDs/Fe(III) as a fluorescent probe. This probe enables the selective detection of PA with a linear range of 0.68-18.69 μM and a limit of detection (signal-to-noise ratio is 3) of 0.36 μM. The assay method demonstrates high selectivity, repeatability, stability and recovery ratio in the detection of the standard and real PA samples. We believe that the facile operation, low-cost, high sensitivity and selectivity render this CD-based "off-on" fluorescent probe an ideal sensing platform for the detection of PA. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. EUNIS Underflight Calibrations of CDS, EIT, TRACE, EIS, and EUVI

    NASA Technical Reports Server (NTRS)

    Thomas, Roger J.; Rabin, Douglas M.; Jess, David B.; Wang, Tongjiang

    2008-01-01

    The Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) is a sounding rocket instrument that obtains imaged high-resolution solar spectra. It has now had two successful flights, on 2006 April 12 and 2007 November 16, providing data to support underflight calibrations for a number of orbiting solar experiments on both occasions. A regular part of each campaign is the end-to-end radiometric calibration of the rocket payload carried out at RAL in the UK, using the same facility that provided pre-flight CDS and EIS calibrations. The measurements, traceable to primary radiometric standards, can establish the absolute EUNIS response within a relative uncertainty of 10% over its full longwave bandpass of 300-370A. During each EUNIS flight, coordinated observations are made of overlapping solar locations by all participating space experiments, and identified by subsequent image co-registrations, allowing the EUNIS calibrations to be applied to these other instruments as well. The calibration transfer is straightforward for wavelengths within the EUNIS LW bandpass, and is extended to other wavelengths by means of a series of 'insensitive' line-ratios, with one line of each pair in the calibrated band and the other in the transfer band. In this way, the EUNIS-06 flight is able to update the radiometric calibrations of CDS NISl (plus 2nd order NIS2 near 2x304A), all four channels of EIT, and the three EUV channels of TRACE. The EUNIS-07 flight will further update those missions, as well as both channels of Hinode/EIT and all four channels of STEREO/SECCHI/EUVI. Future EUNIS flights have been proposed that will continue this underflight calibration service. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

  6. EUNIS Underflight Calibrations of CDS, EIT, TRACE, EIS, and EUVI

    NASA Technical Reports Server (NTRS)

    Thomas, Roger J.; Wang, Tongjiang; Rabin, Douglas M.; Jess, David B.

    2008-01-01

    The Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) is a sounding rocket instrument that obtains imaged high-resolution solar spectra. It has now had two successful flights, on 2006 April 12 and 2007 November 16, providing data to support underflight calibrations for a number of orbiting solar experiments on both occasions. A regular part of each campaign is the end-to-end radiometric calibration of the rocket payload carried out at RAL in the UK, using the same facility that provided pre-flight CDS and EIS calibrations. The measurements, traceable to primary radiometric standards, can establish the absolute EUNIS response within a total uncertainty of 10% over its full longwave bandpass of 300-370A. During each EUNIS flight, coordinated observations are made of overlapping solar locations by all participating space experiments, and identified by subsequent image co-registrations, allowing the EUNIS calibrations to be applied to these other instruments as well. The calibration transfer is straightforward for wavelengths within the EUNIS LW bandpass, and is extended to other wavelengths by means of a series of temperature- and density-insensitive line-ratios, with one line of each pair in the calibrated band and the other in the transfer band. In this way, the EUNIS-06 flight is able to update the radiometric calibrations of CDS NISl (and 2nd-order NIS2 near 2x304A), all four channels of EIT, and the three EUV channels of TRACE. The EUNIS-07 flight will further update those missions, as well as both channels of Hinode/EIS and all four channels of STEREO/SECCHI/EUVI. Future EUNIS flights have been proposed that will continue this underflight calibration service. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

  7. Beyond the EPR: Complementary roles of the hospital-wide electronic health record and clinical departmental systems

    PubMed Central

    2009-01-01

    Background Many hospital departments have implemented small clinical departmental systems (CDSs) to collect and use patient data for documentation as well as for other department-specific purposes. As hospitals are implementing institution-wide electronic patient records (EPRs), the EPR is thought to be integrated with, and gradually substitute the smaller systems. Many EPR systems however fail to support important clinical workflows. Also, successful integration of systems has proven hard to achieve. As a result, CDSs are still in widespread use. This study was conducted to see which tasks are supported by CDSs and to compare this to the support offered by the EPR. Methods Semi-structured interviews with users of 16 clinicians using 15 different clinical departmental systems (CDS) at a Medium-sized University hospital in Norway. Inductive analysis of transcriptions from the audio taped interviews. Results The roles of CDSs were complementary to those of the hospital-wide EPR system. The use of structured patient data was a characteristic feature. This facilitated quality development and supervision, tasks that were poorly supported by the EPR system. The structuring of the data also improved filtering of information to better support clinical decision-making. Because of the high value of the structured patient data, the users put much effort in maintaining their integrity and representativeness. Employees from the departments were also engaged in the funding, development, implementation and maintenance of the systems. Conclusion Clinical departmental systems are vital to the activities of a clinical hospital department. The development, implementation and clinical use of such systems can be seen as bottom-up, user-driven innovations. PMID:19523198

  8. Code Status Reconciliation to Improve Identification and Documentation of Code Status in Electronic Health Records.

    PubMed

    Jain, Viral G; Greco, Peter J; Kaelber, David C

    2017-03-08

    Code status (CS) of a patient (part of their end-of-life wishes) can be critical information in healthcare delivery, which can change over time, especially at transitions of care. Although electronic health record (EHR) tools exist for medication reconciliation across transitions of care, much less attention is given to CS, and standard EHR tools have not been implemented for CS reconciliation (CSR). Lack of CSR creates significant potential patient safety and quality of life issues. To study the tools, workflow, and impact of clinical decision support (CDS) for CSR. We established rules for CS implementation in our EHR. At admission, a CS is required as part of a patient's admission order set. Using standard CDS tools in our EHR, we built an interruptive alert for CSR at discharge if a patient did not have the same inpatient (current) CS at discharge as that prior to admission CS. Of 80,587 admissions over a four year period (2 years prior to and post CSR implementation), CS discordance was seen in 3.5% of encounters which had full code status prior to admission, but Do Not Resuscitate (DNR) CS at discharge. In addition, 1.4% of the encounters had a different variant of the DNR CS at discharge when compared with CS prior to admission. On pre-post CSR implementation analysis, DNR CS per 1000 admissions per month increased significantly among patients discharged and in patients being admitted (mean ± SD: 85.36 ± 13.69 to 399.85 ± 182.86, p<0.001; and 1.99 ± 1.37 vs 16.70 ± 4.51, p<0.001, respectively). EHR enabled CSR is effective and represents a significant informatics opportunity to help honor patients' end-of-life wishes. CSR represents one example of non-medication reconciliation at transitions of care that should be considered in all EHRs to improve care quality and patient safety.

  9. Empirical evaluation of the inter-relationship of articular elements involved in the pathoanatomy of knee osteoarthritis using magnetic resonance imaging.

    PubMed

    Meredith, Dennis S; Losina, Elena; Neumann, Gesa; Yoshioka, Hiroshi; Lang, Philipp K; Katz, Jeffrey N

    2009-10-29

    In this cross-sectional study, we conducted a comprehensive assessment of all articular elements that could be measured using knee MRI. We assessed the association of pathological change in multiple articular structures involved in the pathoanatomy of osteoarthritis. Knee MRI scans from patients over 45 years old were assessed using a semi-quantitative knee MRI assessment form. The form included six distinct elements: cartilage, bone marrow lesions, osteophytes, subchondral sclerosis, joint effusion and synovitis. Each type of pathology was graded using an ordinal scale with a value of zero indicating no pathology and higher values indicating increasingly severe levels of pathology. The principal dependent variable for comparison was the mean cartilage disease score (CDS), which captured the aggregate extent of involvement of articular cartilage. The distribution of CDS was compared to the individual and cumulative distributions of each articular element using the Chi-squared test. The correlations between pathological change in the various articular structures were assessed in a Spearman correlation table. Data from 140 patients were available for review. The cohort had a median age of 61 years (range 45-89) and was 61% female. The cohort included a wide spectrum of OA severity. Our analysis showed a statistically significant trend towards pathological change involving more articular elements as CDS worsened (p-value for trend < 0.0001). Comparison of CDS to change in the severity of pathology of individual articular elements showed statistically significant trends towards more severe pathology as CDS worsened for osteophytes (p-value for trend < 0.0001), bone marrow lesions (p = 0.0003), and subchondral sclerosis (p = 0.009), but not joint effusion or synovitis. There was a moderate correlation between cartilage damage, osteophytes and BMLs as well as a moderate correlation between joint effusion and synovitis. However, cartilage damage and osteophytes were only weakly associated with synovitis or joint effusion. Our results support an inter-relationship of multiple articular elements in the pathoanatomy of knee OA. Prospective studies of OA pathogenesis in humans are needed to correlate these findings to clinically relevant outcomes such as pain and function.

  10. The Impact of Typhoons on the Ocean in the Pacific (ITOP) Field and Data Management Support

    DTIC Science & Technology

    2011-12-16

    in October o f 2009 to develop effective sampling strategies for 20 I 0. EOL /Computing Data and Software Facil ity (CDS) supported the !TO P Dry Run...measurement strategies necessitated a dry run experiment in October of 2009 to develop effective sampling strategies for 2010. EOL /Computing Data and...contains products from 21 September through 32 October 2009. The catalog remains accessible at EOL at the above mentioned uri. The products listed by

  11. Unesco Integrated Documentation Network; Computerized Documentation System (CDS).

    ERIC Educational Resources Information Center

    United Nations Educational, Scientific, and Cultural Organization, Paris (France). Dept. of Documentation, Libraries, and Archives.

    Intended for use by the Computerized Documentation System (CDS), the Unesco version of ISIS (Integrated Set of Information Systems)--originally developed by the International Labour Organization--was developed in 1975 and named CDS/ISIS. This system has a comprehensive collection of programs for input, management, and output, running in batch or…

  12. Preparation of CdS Nanoparticles by First-Year Undergraduates

    ERIC Educational Resources Information Center

    Winkelmann, Kurt; Noviello, Thomas; Brooks, Stephen

    2007-01-01

    The first year undergraduates use a simple method to synthesize 5-nm CdS nanoparticles in a water-in-oil microemulsion. The quantum size effect, the relationship between colors, optical absorbance, band-gap energy and the CdS particles affected by the formation of micelles are observed.

  13. The Ever-Present Demand for Public Computing Resources. CDS Spotlight

    ERIC Educational Resources Information Center

    Pirani, Judith A.

    2014-01-01

    This Core Data Service (CDS) Spotlight focuses on public computing resources, including lab/cluster workstations in buildings, virtual lab/cluster workstations, kiosks, laptop and tablet checkout programs, and workstation access in unscheduled classrooms. The findings are derived from 758 CDS 2012 participating institutions. A dataset of 529…

  14. Effects of coordination agents on the morphology of CdS nanocrystallites synthesized by the hydrothermal method

    NASA Astrophysics Data System (ADS)

    Nie, Qiulin; Yuan, Qiuli; Chen, Weixiang; Xu, Zhude

    2004-05-01

    CdS nanocrystallites were synthesized by the hydrothermal method and characterized by XRD, TEM, and XPS, respectively. Different coordination agents were chosen as the template to investigate their effects on the product morphology. It was found that the CdS nanocrystallites displayed a rod-like shape when ethylenediamine or methylamine were employed as the template. In contrast, only nanoparticles of CdS were observed when ammonia or pyridine were used. Based on our experimental results, a complex structure-controlling mechanism is proposed.

  15. Chemical synthesis of CdS onto TiO2 nanorods for quantum dot sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Pawar, Sachin A.; Patil, Dipali S.; Lokhande, Abhishek C.; Gang, Myeng Gil; Shin, Jae Cheol; Patil, Pramod S.; Kim, Jin Hyeok

    2016-08-01

    A quantum dot sensitized solar cell (QDSSC) is fabricated using hydrothermally grown TiO2 nanorods and successive ionic layer adsorption and reaction (SILAR) deposited CdS. Surface morphology of the TiO2 films coated with different SILAR cycles of CdS is examined by Scanning Electron Microscopy which revealed aggregated CdS QDs coverage grow on increasing onto the TiO2 nanorods with respect to cycle number. Under AM 1.5G illumination, we found the TiO2/CdS QDSSC photoelectrode shows a power conversion efficiency of 1.75%, in an aqueous polysulfide electrolyte with short-circuit photocurrent density of 4.04 mA/cm2 which is higher than that of a bare TiO2 nanorods array.

  16. Bacteria-Derived Carbon Dots Inhibit Biofilm Formation of Escherichia coli without Affecting Cell Growth

    PubMed Central

    Lin, Fengming; Li, Chengcheng; Chen, Zhan

    2018-01-01

    Biofilms are deleterious in many biomedical and industrial applications and prevention of their formation has been a pressing challenge. Here, carbon dots, CDs-LP that were easily synthesized from the biomass of Lactobacillus plantarum by one-step hydrothermal carbonization, were demonstrated to prevent biofilm formation of E. coli. CDs-LP did not thwart the growth of E. coli, indicating the anti-biofilm effect was not due to the bactericidal effect. Moreover, CDs-LP did not affect the growth of the animal cell AT II, showing low cytotoxicity, good safety and excellent biocompatibility. Therefore, CDs-LP could overcome the cytotoxicity issue found in many current antibiofilm agents. CDs-LP represent a new type of anti-biofilm materials, opening up a novel avenue to the development of biofilm treatment. PMID:29503644

  17. The preparation of ethylenediamine-modified fluorescent carbon dots and their use in imaging of cells.

    PubMed

    Dong, Wei; Zhou, Siqi; Dong, Yan; Wang, Jingwen; Ge, Xin; Sui, Lili

    2015-09-01

    In this work, fluorescent carbon dots (CDs) were synthesized using a hydrothermal method with glucose as the carbon source and were surface-modified with ethylenediamine. The properties of as-prepared CDs were analyzed by transmission electron microscopy (TEM), Fourier transform infrared (FTIR), ultraviolet-visible light (UV/vis) absorption and fluorescent spectra. Furthermore, CDs conjugated with mouse anti-(human carcinoembryonic antigen) (CEA) monoclonal antibody were successful employed in the biolabeling and fluorescent imaging of human gastric carcinoma cells. In addition, the cytotoxicity of CDs was also tested using human gastric carcinoma cells. There was no apparent cytotoxicity on human gastric carcinoma cells. These results suggest the potential application of the as-prepared CDs in bioimaging and related fields. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Photoluminescence and structural characteristics of CdS nanoclusters synthesized by hydrothermal microemulsion

    NASA Astrophysics Data System (ADS)

    Liu, Bing; Xu, G. Q.; Gan, L. M.; Chew, C. H.; Li, W. S.; Shen, Z. X.

    2001-01-01

    Spherical and uniform CdS nanoclusters were synthesized by hydrothermal microemulsion. The reaction of Cd2+ ions with S2- ions generated from the decomposition of thioacetamide proceeded in water microdroplets. The mean diameter of the CdS nanoclusters can be varied from 20 to 80 nm by increasing the reaction temperature from 30 to 120 °C. XRD results indicate that the resulting CdS nanoclusters have a reduced and distorted hexagonal lattice compared to bulk materials. Two intense luminescence bands, i.e., green and red, were observed to coexist in the CdS nanoclusters. Their peak positions and relative intensities were found to be sensitive to the size and structure of nanoclusters. These emissions are attributed to surface defects (green emission) and the Cd-Cl composite vacancies (red emission).

  19. Enhanced photocatalytic hydrogen evolution from in situ formation of few-layered MoS2/CdS nanosheet-based van der Waals heterostructures.

    PubMed

    Iqbal, Shahid; Pan, Ziwei; Zhou, Kebin

    2017-05-25

    Here we report for the first time that the H 2 bubbles generated by photocatalytic water splitting are effective in the layer-by-layer exfoliation of MoS 2 nanocrystals (NCs) into few layers. The as-obtained few layers can be in situ assembled with CdS nanosheets (NSs) into van der Waals heterostructures (vdWHs) of few-layered MoS 2 /CdS NSs which, in turn, are effective in charge separation and transfer, leading to enhanced photocatalytic H 2 production activity. The few-layered MoS 2 /CdS vdWHs exhibited a H 2 evolution rate of 140 mmol g (CdS) -1 h -1 and achieved an apparent quantum yield of 66% at 420 nm.

  20. A study on the enhancement of opto-electronic properties of CdS thin films: seed-assisted fabrication

    NASA Astrophysics Data System (ADS)

    Kumarage, W. G. C.; Wijesundera, R. P.; Seneviratne, V. A.; Jayalath, C. P.; Dassanayake, B. S.

    2017-04-01

    A novel method of fabricating chemical bath deposited CdS thin films (CBD-CdS) by using electrodeposited CdS (ED-CdS) as a seed layer is reported. The resulting thin, compact, uniform and adherent seed-assisted CdS films (ED/CBD-CdS) show enhanced effective surface area compared to both ED-CdS and CBD-CdS. The phase of these CdS films was determined to be hexagonal. The fabricated ED/CBD-CdS films show higher photoelectrochemical (PEC) cell efficiency than either ED-CdS and CBD-CdS thin films. Carrier concentration and flat band potential values for ED/CBD-CdS systems are also found to be superior compared to both ED-CdS and CBD-CdS systems.

  1. Structural and optical properties of Ni-doped CdS thin films prepared by chemical bath deposition method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Premarani, R.; Saravanakumar, S., E-mail: sarophy84@gmail.com; Chandramohan, R.

    2015-06-24

    The structural and optical behavior of undoped Cadmiun Sulphide (CdS) and Ni-doped CdS thinfilms prepared by Chemical Bath Deposition (CBD) technique is reported. The crystallite sizes of the thinfilms have been characterized by X-ray diffraction pattern (XRD). The particle sizes increase with the increase of Ni content in the CdS thinfilms. Scanning Electron Microscope (SEM) results indicated that CdS thinfilms is made up of aggregate of spherical-like particles. The composition was estimated by Energy Dispersive Analysis of X-ray (EDX) and reported. Spectroscopic studies revealed considerable improvement in transmission and the band gap of the films changes with addition of Nimore » dopant that is associated with variation in crystallite sizes in the nano regime.« less

  2. Structural, optical and photoelectric properties of sprayed CdS thin films

    NASA Astrophysics Data System (ADS)

    Chandel, Tarun; Dwivedi, Shailendra Kumar; Zaman, M. Burhanuz; Rajaram, P.

    2018-05-01

    In this study, CdS thin films were grown via a facile spray pyrolysis technique. The crystalline phase, morphological, compositional and optical properties of the CdS thin films have been studied using X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and UV-vis absorption spectroscopy, respectively. XRD patterns show that the grown CdS films crystallized in the hexagonal structure. Scanning electron microscopy (SEM) study shows that the surfaces of the films are smooth and are uniformly covered with nanoparticles. EDAX results reveal that the grown films have good stochiometry. UV-vis spectroscopy shows that the grown films have transparency above 80% over the entire visible region. The photo-electric response of the CdS films grown on glass substrates has been observed.

  3. Construction of an all-solid-state artificial Z-scheme system consisting of Bi2WO6/Au/CdS nanostructure for photocatalytic CO2 reduction into renewable hydrocarbon fuel.

    PubMed

    Wang, Meng; Han, Qiutong; Li, Liang; Tang, Lanqin; Li, Haijin; Zhou, Yong; Zou, Zhigang

    2017-07-07

    An all-solid-state Bi 2 WO 6 /Au/CdS Z-scheme system was constructed for the photocatalytic reduction of CO 2 into methane in the presence of water vapor. This Z-scheme consists of ultrathin Bi 2 WO 6 nanoplates and CdS nanoparticles as photocatalysts, and a Au nanoparticle as a solid electron mediator offering a high speed charge transfer channel and leading to more efficient spatial separation of electron-hole pairs. The photo-generated electrons from the conduction band (CB) of Bi 2 WO 6 transfer to the Au, and then release to the valence band (VB) of CdS to recombine with the holes of CdS. It allows the electrons remaining in the CB of CdS and holes in the VB of Bi 2 WO 6 to possess strong reduction and oxidation powers, respectively, leading the Bi 2 WO 6 /Au/CdS to exhibit high photocatalytic reduction of CO 2 , relative to bare Bi 2 WO 6 , Bi 2 WO 6 /Au, and Bi 2 WO 6 /CdS. The depressed hole density on CdS also enhances the stability of the CdS against photocorrosion.

  4. Optical and structural properties of sputtered CdS films for thin film solar cell applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Donguk; Park, Young; Kim, Minha

    2015-09-15

    Graphical abstract: Photo current–voltage curves (a) and the quantum efficiency (QE) (b) for the solar cell with CdS film grown at 300 °C. - Highlights: • CdS thin films were grown by a RF magnetron sputtering method. • Influence of growth temperature on the properties of CdS films was investigated. • At higher T{sub g}, the crystallinity of the films improved and the grains enlarged. • CdS/CdTe solar cells with efficiencies of 9.41% were prepared at 300 °C. - Abstract: CdS thin films were prepared by radio frequency magnetron sputtering at various temperatures. The effects of growth temperature on crystallinity,more » surface morphology and optical properties of the films were characterized with X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), Raman spectra, UV–visible spectrophotometry, and photoluminescence (PL) spectra. As the growth temperature was increased, the crystallinity of the sputtered CdS films was improved and the grains were enlarged. The characteristics of CdS/CdTe thin film solar cell appeared to be significantly influenced by the growth temperature of the CdS films. Thin film CdS/CdTe solar cells with efficiencies of 9.41% were prepared at a growth temperature of 300 °C.« less

  5. Co-sensitization of ZnO by CdS quantum dots in natural dye-sensitized solar cells with polymeric electrolytes to improve the cell stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Junhom, W.; Magaraphan, R.

    2015-05-22

    The CdS quantum dots (QDs) were deposited on ZnO layer by chemical bath deposition method to absorb light in the shorter wavelength region and used as photoanode in the dye sensitized solar cell (DSSCs) with natural dye extracted from Noni leaves. Microstructures of CdS-ZnO from various dipping time were characterized by XRD, FE-SEM and EDX. The results showed that the CdS is hexagonal structure and the amount of CdS increases when the dipping time increases. The maximal conversion efficiency of 0.292% was achieved by the DSSCs based on CdS QDs-sensitized ZnO film obtained from 9 min-dipping time. Furthermore, the stability ofmore » DSSCs was improved by using polymeric electrolyte. Poly (acrylic acid) (PAA) and Polyacrylamide (PAM) were introduced to CdS QDs-sensitized ZnO film from 9 min-dipping time. Each polymeric electrolyte was prepared by swelling from 0.1-2.0 %w in H2O. The maximal conversion efficiency of 0.207% was achieved for DSSCs based on CdS QDs-sensitized ZnO film with PAM 1.0% and the conversion efficiency was decreased 25% when it was left for1 hr.« less

  6. Co-sensitization of ZnO by CdS quantum dots in natural dye-sensitized solar cells with polymeric electrolytes to improve the cell stability

    NASA Astrophysics Data System (ADS)

    Junhom, W.; Magaraphan, R.

    2015-05-01

    The CdS quantum dots (QDs) were deposited on ZnO layer by chemical bath deposition method to absorb light in the shorter wavelength region and used as photoanode in the dye sensitized solar cell (DSSCs) with natural dye extracted from Noni leaves. Microstructures of CdS-ZnO from various dipping time were characterized by XRD, FE-SEM and EDX. The results showed that the CdS is hexagonal structure and the amount of CdS increases when the dipping time increases. The maximal conversion efficiency of 0.292% was achieved by the DSSCs based on CdS QDs-sensitized ZnO film obtained from 9 min-dipping time. Furthermore, the stability of DSSCs was improved by using polymeric electrolyte. Poly (acrylic acid) (PAA) and Polyacrylamide (PAM) were introduced to CdS QDs-sensitized ZnO film from 9 min-dipping time. Each polymeric electrolyte was prepared by swelling from 0.1-2.0 %w in H2O. The maximal conversion efficiency of 0.207% was achieved for DSSCs based on CdS QDs-sensitized ZnO film with PAM 1.0% and the conversion efficiency was decreased 25% when it was left for1 hr.

  7. Cu doping concentration effect on the physical properties of CdS thin films obtained by the CBD technique

    NASA Astrophysics Data System (ADS)

    Albor Aguilera, M. L.; Flores Márquez, J. M.; Remolina Millan, A.; Matsumoto Kuwabara, Y.; González Trujillo, M. A.; Hernández Vásquez, C.; Aguilar Hernandez, J. R.; Hernández Pérez, M. A.; Courel-Piedrahita, M.; Madeira, H. T. Yee

    2017-08-01

    Cu(In, Ga)Se2 (CIGS) and Cu2ZnSnS4 (CZTS) semiconductors are direct band gap materials; when these types of material are used in solar cells, they provide efficiencies of 22.1% and 12.6%, respectively. Most traditional fabrication methods involve expensive vacuum processes including co-evaporation and sputtering techniques, where films and doping are conducted separately. On the other hand, the chemical bath deposition (CBD) technique allows an in situ process. Cu-doped CdS thin films working as a buffer layer on solar cells provide good performing devices and they may be deposited by low cost techniques such as chemical methods. In this work, Cu-doped CdS thin films were deposited using the CBD technique on SnO2:F (FTO) substrates. The elemental analysis and mapping reconstruction were conducted by EDXS. Morphological, optical and electrical properties were studied, and they revealed that Cu doping modified the CdS structure, band-gap value and the electrical properties. Cu-doped CdS films show high resistivity compared to the non-doped CdS. The appropriate parameters of Cu-doped CdS films were determined to obtain an adequate window or buffer layer on CIGS and CZTS photovoltaic solar cells.

  8. Investigations on structural, vibrational, morphological and optical properties of CdS and CdS/Co films by ultrasonic spray pyrolysis

    NASA Astrophysics Data System (ADS)

    Aksay, S.; Polat, M.; Özer, T.; Köse, S.; Gürbüz, G.

    2011-09-01

    CdS and CdS/Co films have been deposited on glass substrates by an ultrasonic spray pyrolysis method. The effects of Co incorporation on the structural, optical, morphological, elemental and vibrational properties of these films were investigated. XRD analysis confirmed the hexagonal wurtzite structure of all films and had no impurity phase. While CdS film has (0 0 2) as the preferred orientation, CdS/Co films have (1 1 0) as the preferred orientation. The direct optical band gap was found to decrease from 2.42 to 2.39 eV by Co incorporation. The decrease of the direct energy gaps by increasing Co contents is mainly due to the sp-d exchange interaction between the localized d-electrons of Co2+ ions and band electrons of CdS. After the optical investigations, it was seen that the transmittance of CdS films decreased by Co content. The Raman measurements revealed two peaks corresponding to the 1LO and 2LO modes of hexagonal CdS. The vibrational modes of Cd-S were obtained in the wavenumber range (590-715 cm-1) using Fourier transform infrared spectroscopy (FTIR). The elemental analysis of the film was done by energy dispersive X-ray spectrometry.

  9. Efficient color-tunable multiexcitonic dual wavelength emission from Type II semiconductor tetrapods.

    PubMed

    Wu, Wen-Ya; Li, Mingjie; Lian, Jie; Wu, Xiangyang; Yeow, Edwin K L; Jhon, Mark H; Chan, Yinthai

    2014-09-23

    We synthesized colloidal InP/ZnS seeded CdS tetrapods by harnessing the structural stability of the InP/ZnS seed nanocrystals at the high reaction temperatures needed to grow the CdS arms. Because of an unexpected Type II band alignment at the interface of the InP/ZnS core and CdS arms that enhanced the occurrence of radiative excitonic recombination in CdS, these tetrapods were found to be capable of exhibiting highly efficient multiexcitonic dual wavelength emission of equal intensity at spectrally distinct wavelengths of ∼485 and ∼675 nm. Additionally, the Type II InP/ZnS seeded CdS tetrapods displayed a wider range of pump-dependent emission color-tunability (from red to white to blue) within the context of a CIE 1931 chromaticity diagram and possessed higher photostability due to suppressed multiexcitonic Auger recombination when compared to conventional Type I CdSe seeded CdS tetrapods. By employing time-resolved spectroscopy measurements, we were able to attribute the wide emission color-tunability to the large valence band offset between InP and CdS. This work highlights the importance of band alignment in the synthetic design of semiconductor nanoheterostructures, which can exhibit color-tunable multiwavelength emission with high efficiency and photostability.

  10. Effect of CdS Growth Time on the Optical Properties of One-Pot Preparation of CdS-Ag2S Binary Compounds

    NASA Astrophysics Data System (ADS)

    Karimipour, M.; Izadian, L.; Molaei, M.

    2018-02-01

    CdS-Ag2S binary nanoparticles were synthesized using a facile one-pot microwave irradiation method. The effect of initial nucleation of CdS quantum dots (QDs) using 3 min, 5 min, and 7 min of microwave irradiation on the optical properties of the final compound was studied. The composition and crystal structure of the compounds were verified using energy dispersive x-ray spectroscopy and x-ray diffraction. They revealed that existence of Ag and Cd elements with an atomic ratio of 0.19 crystalizes in the form of monoclinic Ag2S and hexagonal CdS. Scanning electron microscope images showed a spherical morphology of the resultant compound, and transmission electron microscope images showed the formation of fine particles of CdS-Ag2S composites with an average size of 5-7 nm and 10-14 nm for CdS and Ag2S, respectively. Photoluminescence spectroscopy revealed that the initial growth time of CdS has a crucial effect on the emission of binary compounds such that for 3 min and 5 min of irradiation of CdS solution, the binary compound obtains strong red and considerable near-IR emission (850 nm), but for longer time, it rapidly quenches. The results indicate that the strong red emission can be tuned from 600 nm up to 700 nm with prolonging nucleation time of CdS. This study also emphasized that the origin of red emission strongly depends on the size and defects created in the CdS QDs.

  11. Studies on growth mechanism and physical properties of hydrothermally synthesized CdS with novel hierarchical superstructures and their photocatalytic activity

    NASA Astrophysics Data System (ADS)

    Jamble, Shweta N.; Ghoderao, Karuna P.; Kale, Rohidas B.

    2018-03-01

    A simple, facile and organic-free hydrothermal method was utilized to synthesize cadmium sulfide (CdS) superstructures. The cadmium chloride and thiourea used as a Cd2+ and S2- ion sources for the growth of CdS superstructures. The reaction was carried out at different time and temperatures. The X-ray diffraction studies confirmed that the obtained products were highly crystalline with hexagonal phase. Scanning and transmission electron microscopy images reveal a monodisperse dendrite-like CdS superstructure. It consisted of a central long trunk with secondary branches, lying parallel to each other and making a certain angle with the central trunk, and small ternary branches grew out of the secondary branches. The selected area electron diffraction altogether with high-resolution electron microscopy patterns depicted that the leaves of dendrite were single crystalline in nature and preferentially grown along (111) direction. The UV-vis absorbance and photoluminescence study illustrated that the hierarchically grown CdS superstructures revealed the good quality of optical properties. A probable growth mechanism for the formation of CdS dendritic superstructures was also discussed and demonstrated by experimental results. The photocatalytic activity of CdS superstructures was studied with the photodegradation of methylene blue (MB) in an aqueous solution, under the visible light irradiation. The results showed that the degradation ratio of MB could reach 94.93% in 220 min. Based on the results, the possible mechanism of the photocatalytic reaction of MB with CdS dendrites is useful for visible light photocatalytic applications.

  12. Surface and interface of epitaxial CdTe film on CdS buffered van der Waals mica substrate

    DOE PAGES

    Yang, Y. -B.; Seewald, L.; Mohanty, Dibyajyoti; ...

    2017-03-31

    We report single crystal CdTe films are desirable for optoelectronic device applications. An important strategy of creating films with high crystallinity is through epitaxial growth on a proper single crystal substrate. We report the metalorganic chemical vapor deposition of epitaxial CdTe films on the CdS/mica substrate. The epitaxial CdS film was grown on a mica surface by thermal evaporation. Due to the weak van der Waals forces, epitaxy is achieved despite the very large interface lattice mismatch between CdS and mica (~21–55%). The surface morphology of mica, CdS and CdTe were quantified by atomic force microscopy. The near surface structures, orientations and texture of CdTe and CdS films were characterized by the unique reflection high-energy electron diffraction surface pole figure technique. The interfaces of CdTe and CdS films and mica were characterized by X-ray pole figure technique and transmission electron microscopy. The out-of-plane and in-plane epitaxy of the heteroepitaxial films stack are determined to be CdTe(111)//CdS(0001)//mica(001) and [more » $$\\overline{1}2\\overline{1}$$] CdTe//[$$\\overline{1}100$$] CdS//[010] mica, respectively. The measured photoluminescence (PL), time resolved PL, photoresponse, and Hall mobility of the CdTe/CdS/mica indicate quality films. Finally, the use of van der Waals surface to grow epitaxial CdTe/CdS films offers an alternative strategy towards infrared imaging and solar cell applications.« less

  13. Surface and interface of epitaxial CdTe film on CdS buffered van der Waals mica substrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Y. -B.; Seewald, L.; Mohanty, Dibyajyoti

    We report single crystal CdTe films are desirable for optoelectronic device applications. An important strategy of creating films with high crystallinity is through epitaxial growth on a proper single crystal substrate. We report the metalorganic chemical vapor deposition of epitaxial CdTe films on the CdS/mica substrate. The epitaxial CdS film was grown on a mica surface by thermal evaporation. Due to the weak van der Waals forces, epitaxy is achieved despite the very large interface lattice mismatch between CdS and mica (~21–55%). The surface morphology of mica, CdS and CdTe were quantified by atomic force microscopy. The near surface structures, orientations and texture of CdTe and CdS films were characterized by the unique reflection high-energy electron diffraction surface pole figure technique. The interfaces of CdTe and CdS films and mica were characterized by X-ray pole figure technique and transmission electron microscopy. The out-of-plane and in-plane epitaxy of the heteroepitaxial films stack are determined to be CdTe(111)//CdS(0001)//mica(001) and [more » $$\\overline{1}2\\overline{1}$$] CdTe//[$$\\overline{1}100$$] CdS//[010] mica, respectively. The measured photoluminescence (PL), time resolved PL, photoresponse, and Hall mobility of the CdTe/CdS/mica indicate quality films. Finally, the use of van der Waals surface to grow epitaxial CdTe/CdS films offers an alternative strategy towards infrared imaging and solar cell applications.« less

  14. Synthesis and characterization of CdS-based ternary composite for enhanced visible light-driven photocatalysis

    NASA Astrophysics Data System (ADS)

    Singh, Arvind; Sinha, A. S. K.

    2018-09-01

    Active ternary graphite and alumina-supported cadmium sulphide (CdS) composite was synthesized by impregnation method followed by high-temperature solid-gas reaction and characterized by X-ray diffraction (XRD), photoluminescence spectroscopy (PL), diffuse reflectance spectroscopy (DRS), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) techniques. The ternary CdS-graphite-alumina composite exhibited superior catalytic activity compared with the binary CdS-alumina composite due to its better visible-light absorption and higher charge separation. The ternary composite has a bed-type structure. It permits a greater interaction at the interface due to intimate contact between CdS and graphite in the ternary composite. This composite has a highly efficient visible light-driven photocatalytic activity for sustainable hydrogen production. It is also capable of degrading organic dyes in wastewater.

  15. Concept Definition Study for In-Space Structural Characterization of a Lightweight Solar Array

    NASA Technical Reports Server (NTRS)

    Woods-Vedeler, Jessica A.; Pappa, Richard S.; Jones, Thomas W.; Spellman, Regina; Scott, Willis; Mockensturm, Eric M.; Liddle, Donn; Oshel, Ed; Snyder, Michael

    2002-01-01

    A Concept Definition Study (CDS) was conducted to develop a proposed "Lightweight High-Voltage Stretched-Lens Concentrator Solar Array Experiment" under NASA's New Millennium Program Space Technology-6 (NMP ST-6) activity. As part of a multi-organizational team, NASA Langley Research Center's role in this proposed experiment was to lead Structural Characterization of the solar array during the flight experiment. In support of this role, NASA LaRC participated in the CDS to de.ne an experiment for static, dynamic, and deployment characterization of the array. In this study, NASA LaRC traded state-of-the-art measurement approaches appropriate for an in-space, STS-based flight experiment, provided initial analysis and testing of the lightweight solar array and lens elements, performed a lighting and photogrammetric simulation in conjunction with JSC, and produced an experiment concept definition to meet structural characterization requirements.

  16. 76 FR 70206 - Self-Regulatory Organizations; ICE Clear Credit LLC; Notice of Filing of Proposed Rule Change to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... highly correlated relationship between long-short positions in CDS Indices and the underlying CDS Single... currently clear CDS Single Names for customer-related transactions. Accordingly, currently, there are no customer-related positions that would qualify for portfolio margining treatment. ICC does not believe that...

  17. 78 FR 13130 - Self-Regulatory Organizations; ICE Clear Europe Limited; Order Approving Proposed Rule Change, as...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-26

    ... already the case for single-name CDS). Recognizing the highly correlated relationship between long-short...' proprietary positions. ICE Clear Europe does not currently clear CDS positions of customers of its Clearing Members, but it plans to introduce customer clearing for CDS upon receipt of applicable regulatory...

  18. 78 FR 9088 - Self-Regulatory Organizations; ICE Clear Europe Limited; Order Approving Proposed Rule Change To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-07

    ... Customer Clearing Model for CDS Products and To Amend, Clarify, and Consolidate Certain Rules and... the proposed rule change is to provide for a Customer CDS Clearing Model whereby customers of ICE... changes that are unrelated to Customer CDS Clearing Model. Currently, ICE Clear Europe Clearing Members...

  19. The Financial Management System: A Pivotal Tool for Fiscal Viability. CDS Spotlight. ECAR Research Bulletin

    ERIC Educational Resources Information Center

    Lang, Leah; Pirani, Judith A.

    2014-01-01

    This spotlight focuses on data from the 2013 CDS to better understand how higher education institutions approach financial management systems. Information provided for this spotlight was derived from Module 8 of Core Data Service (CDS), which asked several questions regarding information systems and applications. Responses from 525 institutions…

  20. BI Reporting, Data Warehouse Systems, and Beyond. CDS Spotlight Report. Research Bulletin

    ERIC Educational Resources Information Center

    Lang, Leah; Pirani, Judith A.

    2014-01-01

    This Spotlight focuses on data from the 2013 Core Data Service [CDS] to better understand how higher education institutions approach business intelligence (BI) reporting and data warehouse systems (see the Sidebar for definitions). Information provided for this Spotlight was derived from Module 8 of CDS, which contains several questions regarding…

  1. Caudal dysplasia sequence with penile enlargement: case report and a potential pathogenic hypothesis.

    PubMed

    Makhoul, I R; Aviram-Goldring, A; Paperna, T; Sujov, P; Rienstein, S; Smolkin, T; Epelman, M; Gershoni-Baruch, R

    2001-02-15

    The clinical spectrum of caudal dysplasia sequence (CDS) is noted for its diversity. The origin of CDS remains unknown, though poorly controlled gestational diabetes has been implicated in some cases. Here we describe the case of a newborn with CDS associated with penile enlargement (PE). The main anomalies included anal atresia, agenesis of the kidneys and of the sacrococcygeal vertebrae, dysgenesis of lumbar vertebrae, and bilateral cryptorchidism. Penile enlargement (7 cm), a rather unusual finding, has so far not been reported in association with CDS. Chromosomal analysis failed, and the neonate died 30 min after birth. Comparative genomic hybridization analysis using stored DNA showed a balanced normal male DNA content, which negates chromosomal losses or gains as a cause of CDS and/or PE. PE due to virilizing-type adrenal hyperplasia, caused by common mutations in the genes encoding for the adrenal enzymes 21-hydroxylase and 11-hydroxylase, was ruled out. We report on a previously unpublished case of the coexistence of PE and severe CDS and propose a possible pathogenetic hypothesis of this association. Copyright Wiley-Liss. Inc.

  2. The diagnostic accuracy of Clinical Dehydration Scale in identifying dehydration in children with acute gastroenteritis: a systematic review.

    PubMed

    Falszewska, Anna; Dziechciarz, Piotr; Szajewska, Hania

    2014-10-01

    To systematically update diagnostic accuracy of the Clinical Dehydration Scale (CDS) in clinical recognition of dehydration in children with acute gastroenteritis. Six databases were searched for diagnostic accuracy studies in which population were children aged 1 to 36 months with acute gastroenteritis; index test was the CDS; and reference test was post-illness weight gain. Three studies involving 360 children were included. Limited evidence showed that in high-income countries the CDS provides strong diagnostic accuracy for ruling in moderate and severe (>6%) dehydration (positive likelihood ratio 5.2-6.6), but has limited value for ruling it out (negative likelihood ratio 0.4-0.55). In low-income countries, the CDS has limited value either for ruling moderate or severe dehydration in or out. In both settings, the CDS had limited value for ruling in or out dehydration <3% or dehydration 3% to 6%. The CDS can help assess moderate to severe dehydration in high-income settings. Given the limited data, the evidence should be viewed with caution. © The Author(s) 2014.

  3. Emitting color tunable carbon dots by adjusting solvent towards light-emitting devices

    NASA Astrophysics Data System (ADS)

    Zhu, Jinyang; Bai, Xue; Bai, Jialin; Pan, Gencai; Zhu, Yongsheng; Zhai, Yue; Shao, He; Chen, Xu; Dong, Biao; Zhang, Hanzhuang; Song, Hongwei

    2018-02-01

    Carbon dots (CDs), one of the most significant classes of carbon-based nanophosphors, have attracted extensive attention in recent years. However, few attempts have been reported for realizing CDs with tunable emissions, especially for obtaining the red-light emissions with high photoluminescence quantum yields. Herein, we synthesized CDs with different chromatic blue, green and red emissions by facilely changing the reaction solvent during hydrothermal conditions. The photoluminescence quantum yields of 34%, 19% and 47% for the blue, green and red emissions, respectively, were achieved. Furthermore, the solid-state CD/PVA composite films were constructed through mixing the CDs with PVA polymer, in which the self-quenching of photoluminescence of CDs had been successfully avoided benefiting from the formation of hydrogen bonds between the CDs and PVA molecules. Finally, the warm white light emitting diode (WLED) was fabricated by integrating CD/PVA film on a UV-LED chip. The WLED exhibited the Commission International de l’Eclairage coordinates (CIE) of (0.38, 0.34), correlated color temperature of 3913 K and color rendering index of 91, respectively, which were comparable with the commercial WLEDs.

  4. Microstructural and optical properties of CdS nanoparticles synthesized by sol gel method

    NASA Astrophysics Data System (ADS)

    Mahdi, Hadeel Salih; Parveen, Azra; Agrawal, Shraddha; Azam, Ameer

    2018-05-01

    Semiconductor nanoparticles of CdS are of great interest for both fundamental research and industrial development due to their unique size-dependent optical and electronic properties and their exciting utilization in the fields of light-emitting diode, electro-chemical cells, laser, hydrogen producing catalyst, biological label. We present a scheme to measure the optical properties of CdS nanoparticles The peaks were indexed by powder-x software. The XRD pattern analysis showed that CdS composition was found to have hexagonal structure with well crystalline nature. the surface morphology and the composition of the samples were investigated by SEM (JEOL, japan). The image shows the presence of large spherical aggregates of smaller individual nanoparticles of various sizes for pure cds. to check the chemical composition of the material, energy dispersive X-ray (EDX) spectroscopic analysis was also performed which further confirmed the presence of cd and s ions in the matrix. The optical absorption spectra of CdS sample was recorded by uv-vis spectrophotometer in the range of 200 to 800 nm.

  5. Rapid microwave-assisted synthesis of highly luminescent nitrogen-doped carbon dots for white light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Wang, Yaling; Zheng, Jingxia; Wang, Junli; Yang, Yongzhen; Liu, Xuguang

    2017-11-01

    Highly luminescent nitrogen-doped carbon dots (N-CDs) were synthesized rapidly by one-step microwave-assisted hydrothermal method using citric acid as carbon source and ethylenediamine as dopant. The influences of reaction temperature, reaction time and raw material ratio on the fluorescence performance of N-CDs were investigated. Then N-CDs with the highest quantum yield were selected as fluorescent materials for fabricating white light-emitting diodes (LEDs). Highly luminescent N-CDs with the quantum yield of 75.96% and blue-to-red spectral composition of 51.48% were obtained at the conditions of 180 °C, 8 min and the molar ratio of citric acid to ethylenediamine 2:1. As-prepared highly luminescent N-CDs have an average size of 6.06 nm, possess extensive oxygen- and nitrogen-containing functional groups on their surface, and exhibit strong absorption in ultraviolet region. White LEDs based on the highly luminescent N-CDs emit warm white light with color coordinates of (0.42, 0.40) and correlated color temperature of 3416 K.

  6. Harmane and harmalan are bioactive components of classical clonidine-displacing substance.

    PubMed

    Parker, Christine A; Anderson, Neil J; Robinson, Emma S J; Price, Rhiannon; Tyacke, Robin J; Husbands, Stephen M; Dillon, Michael P; Eglen, Richard M; Hudson, Alan L; Nutt, David J; Crump, Matthew P; Crosby, John

    2004-12-28

    Elucidation of the structure of the endogenous ligand(s) for imidazoline binding sites, clonidine-displacing substance (CDS), has been a major goal for many years. Crude CDS from bovine lung was purified by reverse-phase high-pressure liquid chromatography. Electrospray mass spectrometry (ESMS) and nuclear magnetic resonance ((1)H NMR) analysis revealed the presence of L-tryptophan and 1-carboxy-1-methyltetrahydro-beta-carboline in the active CDS extract. Competition radioligand binding studies, however, failed to show displacement of specific [(3)H]clonidine binding to rat brain membranes for either compound. Further purification of the bovine lung extract allowed the isolation of the beta-carbolines harmane and harmalan as confirmed by ESMS, (1)H NMR, and comparison with synthetic standards. Both compounds exhibited a high (nanomolar) affinity for both type 1 and type 2 imidazoline binding sites, and the synthetic standards were shown to coelute with the active classical CDS extracts. We therefore propose that the beta-carbolines harmane and harmalan represent active components of classical CDS. The identification of these compounds will allow us to establish clear physiological roles for CDS.

  7. Ultrasonic chemical synthesis of CdS-reduced graphene oxide nanocomposites with an enhanced visible light photoactivity

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Chen; Tsai, Du-Cheng; Chang, Zue-Chin; Shieu, Fuh-Sheng

    2018-05-01

    In this study, we report a facile ultrasonic method to prepare a series of CdS and reduced graphene oxide (CdS/rGO) composites with different weight ratios of graphene at temperature as low as 70 °C for 20 min by employing ammonia as a complexing agent of Cd2+ ions and reducing agent of graphene oxide (GO). Pure CdS particles had a poor crystallinity and aggregated to large particles size. As GO was incorporated into CdS, a uniform dispersion of CdS particles with high crystallinity on rGO sheets was clearly observed. The as-prepared CdS/rGO composites have a wide and strong photo absorption in the visible region and display a substantially improved photocatalytic activity for the degradation of methylene blue under visible light irradiation by forming a heterojunction of rGO and CdS. However, too much rGO will shield the light of the active sites for the CdS nanoparticle surface and thus limit further improvement in the photocatalytic efficiency.

  8. Synthesis of Novel Sea-Urchin-Like CdS and Their Optical Properties.

    PubMed

    Kamran, Muhammad Arshad; Liu, Ruibin; Shi, Li-Jie; Bukhtiar, Arfan; Li, Jing; Zou, Bingsuo

    2015-06-01

    A novel morphology of CdS sea-urchin-like microstructures is synthesized by simple thermal evaporation process. Microstructures with average size of 20-50 μm are composed of single crystalline CdS nanobelts. The structural, compositional, morphological characterization of the product were examined by X-ray diffraction, energy dispersive X-ray spectroscopy, Raman spectroscopy, scanning electron microscope, transmission electron microscopy and selected area electron diffraction while optical properties are investigated by Photoluminescence spectroscopy and time-resolved Photoluminescence measurements. The tentative growth mechanism for the growth of sea-urchin-like CdS is proposed and described briefly. A strong green emission with a maximum around 517 nm was observed from the individual CdS microstructure at room temperature, which was attributed to band-edge emission of CdS. These Novel structures exhibit excellent lasing (stimulated emission) with low threshold (9.07 μJ cm(-2)) at room temperature. We analyze the physical mechanism of stimulated emission. These results are important in the design of green luminescence, low-threshold laser and display devices in the future.

  9. ORAC-fluorescein assay to determine the oxygen radical absorbance capacity of resveratrol complexed in cyclodextrins.

    PubMed

    Lucas-Abellán, C; Mercader-Ros, M T; Zafrilla, M P; Fortea, M I; Gabaldón, J A; Núñez-Delicado, E

    2008-03-26

    The effect of the complexation of resveratrol with hydroxypropyl-beta-cyclodextrins (HP-beta-CDs) on the antioxidant capacity of the polyphenol is studied for the first time by means of the oxygen radical absorbance capacity (ORAC) method, using fluorescein (FL) as the fluorescent probe. The method is validated through its linearity, precision, and accuracy for measuring the ORAC of resveratrol in the absence or presence of cyclodextrins (CDs). The complexation of resveratrol in CDs increased the net area under the FL decay curve (net AUC) of resveratrol up to its saturation level, at which the polyphenol showed almost double the antioxidant activity it shows in the absence of CDs. The complexation constant ( K c) between resveratrol and HP-beta-CDs was calculated by linear regression of the phase solubility diagram ( K c = 18048 M (-1)). The antioxidant activity of resveratrol was dependent on the complexed resveratrol because CDs acts as a controlled dosage reservoir that protects resveratrol against rapid oxidation by free radicals. In this way, its antioxidant activity is prolonged and only reaches its maximum when all the resveratrol is complexed.

  10. Preparation of highly luminescent and color tunable carbon nanodots under visible light excitation for in vitro and in vivo bio-imaging

    DOE PAGES

    Zheng, Min; Li, Jing; Xie, Zhigang; ...

    2015-11-10

    Carbon nanodots (CDs) have generated enormous excitement because of their superiority in water solubility, chemical inertness, low toxicity, ease of functionalization and resistance to photobleaching. Here we report a facile thermal pyrolysis route to prepare CDs with high quantum yield (QY) using citric acid as the carbon source and ethylene diamine derivatives (EDAs) including triethylenetetramine (TETA), tetraethylenepentamine (TEPA) and polyene polyamine (PEPA) as the passivation agents. We find that the CDs prepared from EDAs, such as TETA, TEPA and PEPA, show relatively high photoluminescence (PL) QY (11.4, 10.6, and 9.8%, respectively) at 1 ex of 465 nm. The cytotoxicity ofmore » the CDs has been investigated through in vitro and in vivo bio-imaging studies. The results indicate that these CDs possess low toxicity and good biocompatibility. As a result, the unique properties such as the high PL QY at large excitation wave length and the low toxicity of the resulting CDs make them promising fluorescent nanoprobes for applications in optical bio-imaging and biosensing.« less

  11. Synthesis and characterization of cadmium sulphide thin films prepared by spin coating

    NASA Astrophysics Data System (ADS)

    Chodavadiya, Nisarg; Chapanari, Amisha; Zinzala, Jignesh; Ray, Jaymin; Pandya, Samir

    2018-05-01

    An II-VI group semiconductor is Wide band gap materials and has been widely studied due to their fundamental optical, structural, and electrical properties. Cadmium sulphide (CdS) is one of the most emerged materials in II-VI group. It has many applications such as buffer later in photovoltaic cell, multilayer light emitting diodes, optical filters, thin film field effect transistors, gas sensors, light detectors etc. It is fundamentally an n-type material with an optical band gap of 2.4 eV. Owing to these properties we had studied CdS thin films synthesis and characterized by Raman, Ultraviolet - Visible spectroscopy (UV-VIS) and Hot probe method. CdS thin films were prepared by spin coating of the Cadmium-thiourea precursor solution. Visual inspection after 20 minute thermolysis time the films were looks uniform and shiny pale yellow in color. Raman confirms the A1 vibration of pure CdS. UV-VIS gives the band gap about 2.52 eV, which confirms the formation of nanocrystalline form of CdS. Finally, hot probe signifies the n-type conductivity of the CdS film.

  12. Hot electron induced NIR detection in CdS films.

    PubMed

    Sharma, Alka; Kumar, Rahul; Bhattacharyya, Biplab; Husale, Sudhir

    2016-03-11

    We report the use of random Au nanoislands to enhance the absorption of CdS photodetectors at wavelengths beyond its intrinsic absorption properties from visible to NIR spectrum enabling a high performance visible-NIR photodetector. The temperature dependent annealing method was employed to form random sized Au nanoparticles on CdS films. The hot electron induced NIR photo-detection shows high responsivity of ~780 mA/W for an area of ~57 μm(2). The simulated optical response (absorption and responsivity) of Au nanoislands integrated in CdS films confirms the strong dependence of NIR sensitivity on the size and shape of Au nanoislands. The demonstration of plasmon enhanced IR sensitivity along with the cost-effective device fabrication method using CdS film enables the possibility of economical light harvesting applications which can be implemented in future technological applications.

  13. Algae mediated synthesis of cadmium sulphide nanoparticles and their application in bioremediation

    NASA Astrophysics Data System (ADS)

    Prasad Mandal, Ranju; Sekh, Sanoyaz; Sarkar, Neera Sen; Chattopadhyay, Dipankar; De, Swati

    2016-05-01

    The present work is a study on the biological synthesis of cadmium sulphide (CdS) nanoparticles using blue-green algae that is popularly used as a food supplement. This synthesis is unique in the sense that no external sulphur precursor is required, the CdS nanoparticles are synthesized in situ in the algal medium. The CdS nanoparticles thus synthesized are photoluminescent and can act as highly efficient photocatalysts for degradation of the dye pollutant malachite green. Thus the CdS nanoparticles synthesized in situ in the algae conform to the desired criteria of waste water treatment i.e. biosorption of the pollutant and its subsequent degradation. The novelty of this work also lies in its potential for use in bioremediation by conversion of the toxic Cd(II) ion to less toxic CdS nanoparticles within the algal framework.

  14. The Potential Application of Raw Cadmium Sulfide Nanoparticles as CT Photographic Developer

    NASA Astrophysics Data System (ADS)

    Wu, Qiang; Huang, Lingxin; Li, Zhan; An, Wenzhen; Liu, Dan; Lin, Jin; Tian, Longlong; Wang, Xinling; Liu, Bo; Qi, Wei; Wu, Wangsuo

    2016-04-01

    With the development of science and technology, new applications about nanoparticles should be explored to achieve full-scale knowledge. Therefore, in this work, the toxicity and potential application of raw cadmium sulfide nanoparticles (CdS) in vivo were further studied through ICP-OES and CTs. Surprisingly, CdS exhibited an excellent photographic property, except for finding the accumulation of CdS in the lungs, liver, spleen, and kidney with a strong dependence on time; it is also found that there were a significant uptake in the pancreas for an obvious CT imaging. And the following investigations showed that the raw CdS could damage the tissues accumulating nanoparticles. Through this work, it can be seen that the raw CdS being modified might be an excellent photographic developer for detecting cancers or other diseases.

  15. Transparent sunlight conversion film based on carboxymethyl cellulose and carbon dots.

    PubMed

    You, Yaqin; Zhang, Haoran; Liu, Yingliang; Lei, Bingfu

    2016-10-20

    Transparent sunlight conversion film based on carboxymethyl cellulose (CMC) and carbon dots (CDs) has been developed for the first time through dispersion of CDs in CMC aqueous solution. Due to the hydrogen bonds interaction, CMC can effectively absorb the CDs, whose surfaces are functionalized by lots of polar groups. The results from atomic force microscopy (AFM), scanning electron microscopy (SEM) confirm that the composite film possesses a homogeneous and compact structure. Besides, the CMC matrix neither competes for absorbing excitation light nor absorbs the emissions of CDs, which reserves the inherent optical properties of the individual CDs. The composite films can efficiently convert ultraviolet light to blue light. What's more, the film is transparent and possesses excellent mechanical properties, expected to apply in the field of agricultural planting for sunlight conversion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Ferromagnetism in sphalerite and wurtzite CdS nanostructures

    PubMed Central

    2013-01-01

    Room-temperature ferromagnetism is observed in undoped sphalerite and wurtzite CdS nanostructures which are synthesized by hydrothermal methods. Scanning electron microscopy and transmission electron microscopy results indicate that the sphalerite CdS samples show a spherical-like shape and the wurtzite CdS ones show a flower-like shape, both of which are aggregated by lots of smaller particles. The impurity of the samples has been ruled out by the results of X-ray diffraction, selected-area electron diffraction, and X-ray photoelectron spectroscopy. Magnetization measurements indicate that all the samples exhibit room-temperature ferromagnetism and the saturation magnetization decreases with the increased crystal sizes, revealing that the observed ferromagnetism is defect-related, which is also confirmed by the post-annealing processes. This finding in CdS should be the focus of future electronic and spintronic devices. PMID:23294671

  17. Structural and optical properties of nano-structured CdS thin films prepared by chemical bath deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Rekha, E-mail: rekha.mittal07@gmail.com; Kumar, Dinesh; Chaudhary, Sujeet

    2016-05-06

    Cadmium sulfide (CdS) thin films have been deposited on conducting glass substrates by chemical bath deposition (CBD) technique. The effect of precursor concentration on the structural, morphological, compositional, and optical properties of the CdS films has been studied. Crystal structure of these CdS films is characterized by X-ray diffraction (XRD) and it reveals polycrystalline structure with mixture of cubic and wurtzite phases with grain size decreasing as precursor concentration is increased. Optical studies reveal that the CdS thin films have high transmittance in visible spectral region reaching 90% and the films possess direct optical band gap that decreases from 2.46more » to 2.39 eV with decreasing bath concentration. Our study suggests that growth is nucleation controlled.« less

  18. Chemical Sensors Based on Cyclodextrin Derivatives.

    PubMed

    Ogoshi, Tomoki; Harada, Akira

    2008-08-25

    This review focuses on chemical sensors based on cyclodextrin (CD) derivatives. This has been a field of classical interest, and is now of current interest for numerous scientists. First, typical chemical sensors using chromophore appended CDs are mentioned. Various "turn-off" and "turn-on" fluorescent chemical sensors, in which fluorescence intensity was decreased or increased by complexation with guest molecules, respectively, were synthesized. Dye modified CDs and photoactive metal ion-ligand complex appended CDs, metallocyclodextrins, were also applied for chemical sensors. Furthermore, recent novel approaches to chemical sensing systems using supramolecular structures such as CD dimers, trimers and cooperative binding systems of CDs with the other macrocycle [2]rotaxane and supramolecular polymers consisting of CD units are mentioned. New chemical sensors using hybrids of CDs with p-conjugated polymers, peptides, DNA, nanocarbons and nanoparticles are also described in this review.

  19. White light emitting device based on single-phase CdS quantum dots.

    PubMed

    Li, Feng; Nie, Chao; You, Lai; Jin, Xiao; Zhang, Qin; Qin, Yuancheng; Zhao, Feng; Song, Yinglin; Chen, Zhongping; Li, Qinghua

    2018-05-18

    White light emitting diodes (WLEDs) based on quantum dots (QDs) are emerging as robust candidates for white light sources, however they are suffering from the problem of energy loss resulting from the re-absorption and self-absorption among the employed QDs of different peak wavelengths. It still remains a challenging task to construct WLEDs based on single-phase QD emitters. Here, CdS QDs with short synthesis times are introduced to the fabrication of WLEDs. With a short synthesis time, on one hand, CdS QDs with a small diameter with blue emission can be obtained. On the other hand, surface reconstruction barely has time to occur, and the surface is likely defect-ridden, which enables the existence of a broad emission covering the range of green, yellow and red regions. This is essential for the white light emission of CdS QDs, and is very important for WLED applications. The temporal evolution of the PL spectra for CdS QDs was obtained to investigate the influence of growth time on the luminescent properties. The CdS QDs with a growth time of 0.5 min exhibited a colour rendering index (CRI) of 79.5 and a correlated colour temperature (CCT) of 6238 K. With increasing reaction time, the colour coordinates of the CdS QDs will move away from the white light region in the CIE 1931 chromaticity diagram. By integrating the as prepared white light emission CdS QDs with a violet GaN chip, WLEDs were fabricated. The fabricated WLEDs exhibited a CRI of 87.9 and a CCT of 4619 K, which satisfy the demand of general illumination. The luminous flux and the luminous efficiency of the fabricated WLEDs, being less advanced than current commercial white light sources, can be further improved, meaning there is a need for much more in-depth studies on white light emission CdS QDs.

  20. White light emitting device based on single-phase CdS quantum dots

    NASA Astrophysics Data System (ADS)

    Li, Feng; Nie, Chao; You, Lai; Jin, Xiao; Zhang, Qin; Qin, Yuancheng; Zhao, Feng; Song, Yinglin; Chen, Zhongping; Li, Qinghua

    2018-05-01

    White light emitting diodes (WLEDs) based on quantum dots (QDs) are emerging as robust candidates for white light sources, however they are suffering from the problem of energy loss resulting from the re-absorption and self-absorption among the employed QDs of different peak wavelengths. It still remains a challenging task to construct WLEDs based on single-phase QD emitters. Here, CdS QDs with short synthesis times are introduced to the fabrication of WLEDs. With a short synthesis time, on one hand, CdS QDs with a small diameter with blue emission can be obtained. On the other hand, surface reconstruction barely has time to occur, and the surface is likely defect-ridden, which enables the existence of a broad emission covering the range of green, yellow and red regions. This is essential for the white light emission of CdS QDs, and is very important for WLED applications. The temporal evolution of the PL spectra for CdS QDs was obtained to investigate the influence of growth time on the luminescent properties. The CdS QDs with a growth time of 0.5 min exhibited a colour rendering index (CRI) of 79.5 and a correlated colour temperature (CCT) of 6238 K. With increasing reaction time, the colour coordinates of the CdS QDs will move away from the white light region in the CIE 1931 chromaticity diagram. By integrating the as prepared white light emission CdS QDs with a violet GaN chip, WLEDs were fabricated. The fabricated WLEDs exhibited a CRI of 87.9 and a CCT of 4619 K, which satisfy the demand of general illumination. The luminous flux and the luminous efficiency of the fabricated WLEDs, being less advanced than current commercial white light sources, can be further improved, meaning there is a need for much more in-depth studies on white light emission CdS QDs.

Top