Evaluation of Millstone-2 steam generator chemical decontamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, D.T.; Blok, J.
The steam generator channel heads at Millstone-2 were decontaminated prior to carrying out extensive maintenance work in 1983. Isotopic gamma ray measurements were made of the inner channel head surfaces before and after the decontamination to evaluate the effectiveness of the process. The Combustion Engineering/Kraftwerk Union chemical decontamination, by itself, provided a decontamination factor ranging from 2.7 to 6.6 for the various steam generator surfaces. The corresponding average dose rate reduction factor, based on gross-gamma radiation surveys, was approximately 1.5 to 2.5. Following the chemical treatment, high pressure water flushing reduced the radiation levels still further, to an average overallmore » dose reduction factor of 5.3 to 7.2.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milyutin, V.V.; Gelis, V.M.; Penzin, R.A.
1995-12-31
In this paper the results obtained in field tests of decontaminating radioactive natural and industrial solutions of different chemical and radionuclide composition from cesium and strontium radionuclides are reported. Decontamination of industrial reservoir water at the Production Association Mayak (Chelyabinsk Region, Russia) was performed using CMP synthetic zeolite. Efficient decontamination of the feed water is achieved after preliminary precipitation of hardness salts in the form of carbonates. Decontamination of water from the pool for spent fuel element storage from {sup 137}Cs was conducted using NGA ferricyanide sorbent. Decontamination factors with respect to {sup 137}Cs of 400 have been reached, themore » installation throughput being 100,000 by (bed volumes). Decontamination of liquid radwaste at Murmansk Shipping Co was conducted with CFB, CMP synthetic zeolites and NGA ferricyanide sorbent as well. Decontamination of D and D solutions and wastes of the special laundry resulted in decontamination factors within the range of 20--400, 10--100, and 10--30 with respect to {sup 137}Cs, {sup 90}Sr, and total {beta}-activity, respectively. Installation throughput of 3,000--5,000 bv for zeolites and 8,000--10,000 bv for ferrocyanide sorbents has been reached. Results obtained prove the high efficiency of sorption technique for decontaminating solutions from cesium and strontium radionuclides.« less
Sorption of Radionuclides to Building Materials and its ...
Journal article Urban contamination via a number of radiological release scenarios may require simple decontamination methods that can be deployed for wide-area decontamination. This paper investigates a number of factors of importance for developing such decontamination methods, focusing on cesium.
Showering effectiveness for human hair decontamination of the nerve agent VX.
Josse, Denis; Wartelle, Julien; Cruz, Catherine
2015-05-05
In this work, our goals were to establish whether hair decontamination by showering one hour post-exposure to the highly toxic organophosphate nerve agent VX was effective, whether it required the addition of a detergent to water and, if it could be improved by using the adsorbent Fuller's Earth (FE) or the Reactive Skin Decontamination Lotion (RSDL) 30 min prior to showering. Hair exposure to VX and decontamination was performed by using an in vitro model. Hair showering led to 72% reduction of contamination. Addition of detergent to water slightly increased the decontamination effectiveness. Hair treatment with FE or RSDL improved the decontamination rate. Combination of FE use and showering, which yielded a decontamination factor of 41, was demonstrated to be the most effective hair decontamination procedure. Hair wiping after showering was shown to contribute to hair decontamination. Altogether, our results highlighted the importance of considering hair decontamination as an important part of body surface decontamination protocols. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Public experiences of mass casualty decontamination.
Carter, Holly; Drury, John; Rubin, G James; Williams, Richard; Amlôt, Richard
2012-09-01
In this article, we analyze feedback from simulated casualties who took part in field exercises involving mass decontamination, to gain an understanding of how responder communication can affect people's experiences of and compliance with decontamination. We analyzed questionnaire data gathered from 402 volunteers using the framework approach, to provide an insight into the public's experiences of decontamination and how these experiences are shaped by the actions of emergency responders. Factors that affected casualties' experiences of the decontamination process included the need for greater practical information and better communication from responders, and the need for privacy. Results support previous findings from small-scale incidents that involved decontamination in showing that participants wanted better communication from responders during the process of decontamination, including more practical information, and that the failure of responders to communicate effectively with members of the public led to anxiety about the decontamination process. The similarity between the findings from the exercises described in this article and previous research into real incidents involving decontamination suggests that field exercises provide a useful way to examine the effect of responder communication strategies on the public's experiences of decontamination. Future exercises should examine in more detail the effect of various communication strategies on the public's experiences of decontamination. This will facilitate the development of evidence-based communication strategies intended to reduce anxiety about decontamination and increase compliance among members of the public during real-life incidents that involve mass decontamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zegger, J.L.; Pancer, G.P.
1959-02-15
The caustic permanganante-rinse decontamination studies were performed to determine optimum operating conditions as well as the metallurgical effects of the treatment. A treatment with 10% NaOH and 5% potassium by a rinse with a 5% ammorium citrate, 2% citric acid and 1/2% Versene solution was chosen for the decontamination of a stainless steel steam generator, Decontamination factors of greater than 50 were obtained in loop tests using the above treatment. Corrosion and metallurgical results indicated a total penetration of less than 0.01 mil on annealed type 304 stainless steel with no evidence of any deleterious effects. (auth)
Cao, Yachao; Hui, Xiaoying; Zhu, Hanjiang; Elmahdy, Akram; Maibach, Howard
2018-07-01
This study compared the efficiency for in vitro human skin decontamination using DDGel and RSDL. Experiments were performed using in vitro human skin models, in which skin was mounted onto Flow-Through diffusion cells. The mass of 14 -C CEES removed from skin surface after decontamination was quantitated by measuring radioactivity with a liquid scintillation spectrometer. Both decontaminants removed more than 82% of CEES from skin. DDGel skin decontamination significantly reduced toxicant amount when compared to RSDL. Mean CEES remaining in stratum corneum (SC), viable epidermis, dermis, and systemic absorption of DDGel and RSDL were, 0.12 and 0.55% (P < 0.01), 0.31 and 0.95% (p < 0.01), 1.08 and 2.92% (p < 0.05), 3.13 and 6.34% (p < 0.05), respectively. DDGel showed higher decontamination efficiency (twice decontamination efficacy factor, DEF) than RSDL and efficiently removed chemicals from the skin surface, importantly back-extracted from the SC, and significantly reduced both chemical penetration into skin and systemic absorption. Thus, DDGel can offer a potential as a next generation skin decontamination platform technology for military and civilian applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Low-Level Analytical Methodology Updates to Support Decontaminant Performance Evaluations
2011-06-01
from EPDM and tire rubber coupon materials that were spiked with a known amount of the chemical agent VX, treated with bleach decontaminant, and...to evaluate the performance of bleach decontaminant on EPDM and tire rubber coupons. Dose-confirmation or Tool samples were collected by delivering...components • An aging or damaged analytical column • Dirty detector • Other factors related to general instrument and/or sample analysis performance
Kakamu, Takeyasu; Hidaka, Tomoo; Hayakawa, Takehito; Kumagai, Tomohiro; Jinnouchi, Takanobu; Tsuji, Masayoshi; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2015-01-01
The aim of this study was to reveal factors related to heat illness in radiation decontamination workers and determine effective preventive measures. A self-administered questionnaire was sent to 1,505 radiation decontamination workers. The questionnaire included age, sex, duration of decontamination work, previous occupation, education provided by employers regarding heat illness, preventive action against heat illness, and subjective symptoms of heat illness during work. We included 528 men, who replied and answered all questions, in the statistical analysis. Subjective symptoms of heat illness were categorized as "no symptoms", "Grade I" and "Grade II" according to severity. A multiple linear regression model was used to determine the factors associated with the severity of heat illness. The mean age of the subjects was 47.6 years old (standard deviation: 13.4). Of the 528 workers, 316 (59.8%) experienced heat illness symptoms (213 at Grade I and 103 at Grade II). The results of the stepwise selection revealed that age, outdoor manual labor, adequate sleep, use of a cool vest, and salt intake were selected as preventive factors, whereas living in a company dormitory or temporary housing, wearing light clothing, and consuming breakfast were selected as risk factors for heat illness. Both working conditions and living environment are associated with heat illness in radiation decontamination workers. Type of housing and sleep are also strongly related to heat illness during work. Employers should consider not only the working conditions of the employee but also the employee's daily living conditions, in order to prevent heat illness.
Metal Surface Decontamination by the PFC Solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hui-Jun Won; Gye-Nam Kim; Wang-Kyu Choi
2006-07-01
PFC (per-fluorocarbon) spray decontamination equipment was fabricated and its decontamination behavior was investigated. Europium oxide powder was mixed with the isotope solution which contains Co-60 and Cs-137. The different shape of metal specimens artificially contaminated with europium oxide powder was used as the surrogate contaminants. Before and after the application of the PFC spray decontamination method, the radioactivity of the metal specimens was measured by MCA. The decontamination factors were in the range from 9.6 to 62.4. The spent PFC solution was recycled by distillation. Before and after distillation, the turbidity of PFC solution was also measured. From the testmore » results, it was found that more than 98% of the PFC solution could be recycled by a distillation. (authors)« less
The feasibility study of hot cell decontamination by the PFC spray method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hui-Jun Won; Chong-Hun Jung; Jei-Kwon Moon
2008-01-15
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to bemore » reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation module. A performance test on each module was executed and the results have been reported. A combined test of the four modules, however, has not been performed as yet. The main objective of the present study is to demonstrate the feasibility of the full PFC spray decontamination process. Decontamination of the inside of the IMEF hot cell by the PFC spray method was also performed. PFC spray decontamination process was demonstrated by using a surrogate wall contaminated with Eu{sub 2}O{sub 3} powder. The spray pressure was 41 kgf/cm{sup 2}, the orifice diameter was 0.2 mm and the spray velocity was 0.2 L/min. And, the decontaminated area was 100 cm{sup 2}. From previous test results, we found that the decontamination factor of the PFC spray method was in the range from 9.6 to 62.4. When the decontamination efficiency of Co-60 was high, then the decontamination efficiency of Cs-137 was also high. As the surface roughness of the specimen increased, the PFC spray decontamination efficiency decreased. Inferring from the previous results, the surface of the surrogate wall was cleaned by the PFC spray method. The vacuum cup of the collection module operated well and gathered more than 99 % of the PFC solution. Also, filtration and distillation modules operated well. All the filtered PFC solution flowed to the storage chamber where some of the PFC solution was distilled. The coolant of the distillation module was a dry ice. And, the recycled solution was transferred to the spray module by a high pressure pump. To evaluate the PFC spray decontamination efficiency, a smear device was fabricated and operated by a manipulator. Before and after decontamination, a smear test was performed. The tested area was 100 cm{sup 2} and the radioactivity was estimated indirectly by measuring the radioactivity of the filter paper. The average decontamination factor was in the range between 10 and 15. One application time was 2 minutes. The sprayed PFC solution was collected by the vacuum cup and it was stored in the collection equipment. After the termination of the decontamination test, the flexible hose was cut near a toboggan. The collection equipment that contained the spent PFC solution, vacuum cup, spray nozzle and the flexible hose was stored in a radioactive waste storage tank. A feasibility study for the PFC spray decontamination method for an application to a hot cell surface was performed. The decontamination equipment that consisted of four modules operated well in the hot cell. The collection module gathered the sprayed PFC solution. The solution was purified in the filtration or distillation modules. The main characteristic of the distillation module is the use of dry ice as a coolant. The decontamination factor of IMEF hot cell was in the range from 10 to 15. It was difficult to measure the radioactivity accurately at a given time. We, however, concluded that the PFC spray decontamination method is a promising technology. It generated a small amount of secondary waste and used a non-toxic and non-conducting material. Decontamination work was performed with a little loss of the main decontamination agent. Based on the test results, we are developing an improved PFC spray decontamination process.« less
Xu, Jiawen; Wu, Cuiyu; Deng, Jianbin; Liao, Wenwei; Ling, Yuxiang; Yang, Yuanxiu; Zhao, Yina; Zhao, Yunlin; Hu, Xi; Wang, Hui; Liu, Yunguo
2017-01-01
A method for grafting ethylenediamine to a magnetic graphene oxide composite (EDA-GO@Fe3O4) was developed for Cr(VI) decontamination. The physicochemical properties of EDA-GO@Fe3O4 were characterized using HRTEM, EDS, FT-IR, TG-DSC, and XPS. The effects of pH, sorbent dose, foreign anions, time, Cr(VI) concentration, and temperature on decontamination process were studied. The solution pH can largely affect the decontamination process. The pseudo-second-order model is suitable for being applied to fit the adsorption processes of Cr(VI) with GO@Fe3O4 and EDA-GO@Fe3O4. The intra-particle diffusion is not the rate-controlling step. Isotherm experimental data can be described using the Freundlich model. The effects of multiple factors on the Cr(VI) decontamination was investigated by a 25−1 fractional factorial design (FFD). The adsorption process can significantly be affected by the main effects of A (pH), B (Cr(VI) concentration), and E (Adsorbent dose). The combined factors of AB (pH × Cr(VI) concentration), AE (pH × Adsorbent dose), and BC (Cr(VI) concentration × Temperature) had larger effects than other factors on Cr(VI) removal. These results indicated that EDA-GO@Fe3O4 is a potential and suitable candidate for treatment of heavy metal wastewater. PMID:29084287
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L.; Martin, K.; Hobbs, D.
2012-01-03
Experimental results for the selective removal of strontium and cesium from simulated waste solutions with monosodium titanate and crystalline silicotitanate laden filter cartridges are presented. In these proof-of-principle tests, effective uptake of both strontium-85 and cesium-137 were observed using ion-exchangers in this filter cartridge configuration. At low salt simulant conditions, the instantaneous decontamination factor for strontium-85 with monosodium titanate impregnated filter membrane cartridges measured 26, representing 96% strontium-85 removal efficiency. On the other hand, the strontium-85 instantaneous decontamination factor with co-sintered active monosodium titanate cartridges measured 40 or 98% Sr-85 removal efficiency. Strontium-85 removal with the monosodium titanate impregnated membranemore » cartridges and crystalline silicotitanate impregnated membrane cartridges, placed in series arrangement, produced an instantaneous decontamination factor of 41 compared to an instantaneous decontamination factor of 368 for strontium-85 with co-sintered active monosodium titanate cartridges and co-sintered active crystalline silicotitanate cartridges placed in series. Overall, polyethylene co-sintered active titanates cartridges performed as well as titanate impregnated filter membrane cartridges in the uptake of strontium. At low ionic strength conditions, there was a significant uptake of cesium-137 with co-sintered crystalline silicotitanate cartridges. Tests results with crystalline silicotitanate impregnated membrane cartridges for cesium-137 decontamination are currently being re-evaluated. Based on these preliminary findings we conclude that incorporating monosodium titanate and crystalline silicotitanate sorbents into membranes represent a promising method for the semicontinuous removal of radioisotopes of strontium and cesium from nuclear waste solutions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaminski, Michael D.; Mertz, Carol J.; Kivenas, Nadia
Argonne National Laboratory (Argonne) developed a superabsorbing gel-based process (SuperGel) for the decontamination of cesium from concrete and other porous building materials. Here, we report on results that tested the gel decontamination technology on specific concrete and ceramic formulations from a coastal city in Southeast Asia, which may differ significantly from some U.S. sources. Results are given for the evaluation of americium and cesium sequestering agents that are commercially available at a reasonable cost; the evaluation of a new SuperGel formulation that combines the decontamination properties of cesium and americium; the variation of the contamination concentration to determine the effectsmore » on the decontamination factors with concrete, tile, and brick samples; and pilot-scale testing (0.02–0.09 m2 or 6–12 in. square coupons).« less
Analysis of sepsis in allogeneic bone marrow transplant recipients: a single-center study.
Mitsui, Hideki; Karasuno, Takahiro; Santo, Taisuke; Fukushima, Kentaro; Matsunaga, Hitomi; Nakamura, Hiroyuki; Hiraoka, Akira
2003-09-01
We reviewed the records of 235 consecutive recipients of allogeneic bone marrow transplantation (allo-BMT) at our center between February 1983 and October 2000. Sepsis occurred in 25 patients (10.6%) at a median of 10 days (range, 1-280 days) after BMT. Five of the 25 patients (20%) died of sepsis. Pathogens isolated from blood culture were gram-positive cocci in 19 patients, gram-negative rods in 7, fungi in 2, and others in 1 patient. Two pathogens were detected concomitantly in 4 patients. Univariate analysis revealed that risk factors for sepsis were selective gut decontamination using lomefloxacin hydrochloride and nystatin, an unrelated donor, HLA mismatched BMT, and stomatitis. Multivariate logistic regression analysis revealed that an unrelated donor was the only significant independent risk factor, with a relative risk of 5.432. In 12 of 25 patients with sepsis, the pathogens of sepsis were sensitive to antibiotics used for gut decontamination. Selective gut decontamination significantly increased the incidence of sepsis, especially that with gram-positive cocci, but not the mortality rate of sepsis, compared with total gut decontamination using vancomycin. We also found a significant relationship between pathogens isolated from blood culture and those isolated from surveillance cultures of stool, urine, and gargled water in the period before sepsis occurred. The present study revealed an independent risk factor for sepsis (unrelated donor), the feasibility of selective gut decontamination, and the importance of surveillance culture.
System decontamination as a tool to control radiation fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riess, R.; Bertholdt, H.O.
1995-03-01
Since chemical decontamination of the Reactor Coolant Systems (RCS) and subsystems has the highest potential to reduce radiation fields in a short term this technology has gained an increasing importance. The available decontamination process at Siemens, i.e., the CORD processes, will be described. It is characterized by using permanganic acid for preoxidation and diluted organic acid for the decontamination step. It is a regenerative process resulting in very low waste volumes. This technology has been used frequently in Europe and Japan in both RCS and subsystems. An overview will be given i.e. on the 1993 applications. This overview will includemore » plant, scope, date of performance, system volume specal features of the process removed activities, decon factor time, waste volumes, and personnel dose during decontamination. This overview will be followed by an outlook on future developments in this area.« less
Possibilities of a metal surface radioactive decontamination using a pulsed CO2 laser
NASA Astrophysics Data System (ADS)
Milijanic, Scepan S.; Stjepanovic, Natasa N.; Trtica, Milan S.
2000-01-01
There is a growing interest in the laser radioactive decontamination of metal surfaces. It offers advantages over conventional methods: improved safety, reduction of secondary waste, reduced waste volume, acceptable cost. A main mechanism of cleaning in by lasers is ablation. In this work a pulsed TEA CO2 laser was used for surface cleaning, primarily in order to demonstrate that the ablation from metal surfaces with this laser is possible even with relatively low pulse energies, and secondary, that it could be competitive with other lasers because of much higher energy efficiencies. The laser pulse contains two parts, one strong and shot peak at the beginning, followed with a tail. The beam was focused onto a contaminated surface with a KBr lens. The surface was contaminated with 137Cs. Three different metals were used: stainless steel, copper and aluminum. The evaporated material was pumped out in air atmosphere and transferred to a filter. Presence of the activity on the filter was proved by a germanium detector-multichannel analyzer. Activity levels were measured by a GM counter. Calculated decontamination factors as well as collection factors have shown that ablation takes place with relatively high efficiency of decontamination. This investigation suggests that decontamination using the CO2 laser should be seriously considered.
Smolle, C; Huss, F; Lindblad, M; Reischies, F; Tano, E
2018-01-01
Healthcare textiles are increasingly recognized as potential vehicles for transmission of hospital-acquired infections. This study tested the ability of an automated ultraviolet-C (UV-C) room disinfection device (Tru-D Smart UV-C) to decontaminate textiles inoculated with Enterococcus faecium in a clinical setting. Contaminated polycotton (50/50 polyester/cotton) swatches were distributed to predefined locations in a ward room and exposed to UV-C light. UV-C decontamination reduced E. faecium counts by a mean log 10 reduction factor of 1.37 (all P = 0.005, Wilcoxon signed rank test). UV-C decontamination may be a feasible adjunctive measure to conventional laundering to preserve the cleanliness of healthcare textiles in ward rooms. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Lab-simulated working surface materials. Experimental study design. Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area.
DNA decontamination methods for internal quality management in clinical PCR laboratories.
Wu, Yingping; Wu, Jianyong; Zhang, Zhihui; Cheng, Chen
2018-03-01
The polymerase chain reaction (PCR) technique, one of the most commonly applied methods in diagnostic and molecular biology, has a frustrating downside: the occurrence of false-positive signals due to contamination. In previous research, various DNA decontamination methods have been developed to overcome this limitation. Unfortunately, the use of random or poorly focused sampling methods for monitoring air and/or object surfaces leads to the incomplete elimination during decontamination procedures. We herein attempted to develop a novel DNA decontamination method (environmental surveillance, including surface and air sampling) and quality management program for clinical molecular diagnostic laboratories (or clinical PCR laboratories). Here, we performed a step-by-step evaluation of current DNA decontamination methods and developed an effective procedure for assessing the presence of decontaminating DNA via PCR analysis. Performing targeted environmental surveillance by sampling, which reached optimal performance over 2 weeks, and the decontamination process had been verified as reliable. Additionally, the process was validated to not affect PCR amplification efficiency based on a comparative study. In this study, effective guidelines for DNA decontamination were developed. The method employed ensured that surface DNA contamination could be effectively identified and eliminated. Furthermore, our study highlighted the importance of overall quality assurance and good clinical laboratory practices for preventing contamination, which are key factors for compliance with regulatory or accreditation requirements. Taken together, we provided the evidence that the presented scheme ranged from troubleshooting to the elimination of surface contamination, could serve as critical foundation for developing regular environmental surveillance guidelines for PCR laboratories. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Fink, S. D.
Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), and Caustic Wash Tank (CWT) samples from several of the ?microbatches? of Integrated Salt Disposition Project (ISDP) Salt Batch (?Macrobatch?) 4 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by inductively-coupled plasma emission spectroscopy (ICPES). Furthermore, samples from the CWT have been analyzed by a variety of methods to investigate a decline in the decontamination factor (DF) of the cesium observed at MCU. The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and themore » previous set of results for Macrobatch 3 samples indicate generally consistent operations. There is no indication of a disruption in plutonium and strontium removal. The average cesium DF and concentration factor (CF) for samples obtained from Macrobatch 4 are slightly lower than for Macrobatch 3, but still well within operating parameters. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in Actinide Removal Process (ARP).« less
Conversion of transuranic waste to low level waste by decontamination: a site specific update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, R.P.; Hazelton, R.F.
1985-09-01
As a followup to an FY-1984 cost/benefit study, a program was conducted in FY-1985 to transfer to the relevant DOE sites the information and technology for the direct conversion of transuranic (TRU) waste to low-level waste (LLW) by decontamination. As part of this work, the economic evaluation of the various TRUW volume reduction and conversion options was updated and expanded to include site-specific factors. The results show, for the assumptions used, that size reduction, size reduction followed by decontamination, or in situ decontamination are cost effective compared with the no-processing option. The technology transfer activities included site presentations and discussionsmore » with operations and waste management personnel to identify application opportunities and site-specific considerations and constraints that could affect the implementation of TRU waste conversion principles. These discussions disclosed definite potential for the beneficial application of these principles at most of the sites, but also confirmed the existence of site-specific factors ranging from space limitations to LLW disposal restrictions that could preclude particular applications or diminish expected benefits. 8 refs., 2 figs., 4 tabs.« less
NASA Astrophysics Data System (ADS)
Sathyaseelan, V. S.; Rufus, A. L.; Chandramohan, P.; Subramanian, H.; Velmurugan, S.
2015-12-01
Full system decontamination of Primary Heat Transport (PHT) system of Pressurised Heavy Water Reactors (PHWRs) resulted in low decontamination factors (DF) on stainless steel (SS) surfaces. Hence, studies were carried out with 403 SS and 410 SS that are the material of construction of "End-Fitting body" and "End-Fitting Liner tubes". Three formulations were evaluated for the dissolution of passive films formed over these alloys viz., i) Two-step process consisting of oxidation and reduction reactions, ii) Dilute Chemical Decontamination (DCD) and iii) High Temperature Process. The two-step and high temperature processes could dissolve the oxide completely while the DCD process could remove only 60%. Various techniques like XRD, Raman spectroscopy and SEM-EDX were used for assessing the dissolution process. The two-step process is time consuming, laborious while the high temperature process is less time consuming and is recommended for SS decontamination.
Apparatus and method for simultaneous recovery of hydrogen from water and from hydrocarbons
Willms, R. Scott; Birdsell, Stephen A.
2000-01-01
Apparatus and method for simultaneous recovery of hydrogen from water and from hydrocarbon feed material. The feed material is caused to flow over a heated catalyst which fosters the water-gas shift reaction (H.sub.2 O+COH.sub.2 +CO.sub.2) and the methane steam reforming reaction (CH.sub.4 +H.sub.2 O3 H.sub.2 +CO). Both of these reactions proceed only to partial completion. However, by use of a Pd/Ag membrane which is exclusively permeable to hydrogen isotopes in the vicinity of the above reactions and by maintaining a vacuum on the permeate side of the membrane, product hydrogen isotopes are removed and the reactions are caused to proceed further toward completion. A two-stage palladium membrane reactor was tested with a feed composition of 28% CQ.sub.4, 35% Q.sub.2 O (where Q=H, D, or T), and 31% Ar in 31 hours of continuous operation during which 4.5 g of tritium were processed. Decontamination factors were found to increase with decreasing inlet rate. The first stage was observed to have a decontamination factor of approximately 200, while the second stage had a decontamination factor of 2.9.times.10.sup.6. The overall decontamination factor was 5.8.times.10.sup.8. When a Pt/.alpha.-Al.sub.2 O.sub.3 catalyst is employed, decoking could be performed without catalyst degradation. However, by adjusting the carbon to oxygen ratio of the feed material with the addition of oxygen, coking could be altogether avoided.
Northrop Triga facility decommissioning plan versus actual results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gardner, F.W.
1986-01-01
This paper compares the Triga facility decontamination and decommissioning plan to the actual results and discusses key areas where operational activities were impacted upon by the final US Nuclear Regulatory Commission (NRC)-approved decontamination and decommissioning plan. Total exposures for fuel transfer were a factor of 4 less than planned. The design of the Triga reactor components allowed the majority of the components to be unconditionally released.
Design of dental surgeries in relation to instrument decontamination.
Smith, A J; Lockhart, D E A; McDonald, E; Creanor, S; Hurrell, D; Bagg, J
2010-12-01
Recent guidelines advise that the decontamination of dental instruments should be undertaken outwith the treatment area. The aim of this study was to determine the physical area of rooms in dental surgeries that decontaminate instruments within and outwith the treatment area respectively, and other factors relating to practice layout and ventilation. Data were collected by interview and observation of dental healthcare workers in dental practice in Scotland, UK. Room layouts were recorded and measured at floor, benchtop and above benchtop heights. Thirteen surgeries with instrument decontamination processes occurring in the treatment area and seven surgeries with instrument decontamination outwith the treatment area were selected at random for detailed analysis of room dimensions. Of the 179 dental surgeries surveyed, 55% were located in converted residential premises and most practitioners (91%) did not share premises with other healthcare providers. The median number of rooms in the practices was 8 (range: 2-21) and the median number of surgeries present was 3 (range: 1-6). Regardless of whether instrument decontamination facilities were housed within the treatment area or not, the average treatment area room size for both was 15.8m(2) (range: 7.3-23.9) (P=0.862), with 20% of the room area available as work surfaces. The median size of the seven instrument decontamination rooms (local decontamination units) was 7.6m(2) (range: 2.9-16.0), with, on average, 63% of the room used for work surfaces. This survey suggests that the historical location of dental surgeries in converted residential properties places many restrictions on appropriate design for healthcare premises. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Chemical Decontamination at Browns Ferry Unit 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartwig, Ed; Reid, Richard
2003-09-01
In May, 2002, the Tennessee Valley Authority's (TVA) Board of Directors approved the recovery and restart of Unit 1 at Browns Ferry Nuclear Station. As an initial step in the site characterization and restart feasibility review, a majority of the primary reactor circuit was chemically decontaminated. Close cooperation between TVA and vendor personnel resulted in project completion ahead of schedule with outstanding results. The final average decontamination factors were excellent, and the final dose rates were very low, with contact readings on most points between one and three mRem/hr. In addition to allowing TVA to do a complete and thoroughmore » job of determining the feasibility of the Unit 1 restart, the decontamination effort will greatly reduce personnel exposure during plant recovery, both whole body exposure to gamma radiation and airborne exposure during pipe replacement efforts. The implementation of lessons learned from previous decontamination work performed at Browns Ferry, as well as decontamination efforts at other plants aided greatly in the success. Specific items of note are: (1) The initial leak check of the temporary decontamination system should include ancillary systems such as the spent resin system, as well as the main circulation loop. This could save time and dose exposure if leaks are discovered before the use of such systems is required. (2) Due to the quick turnaround time from the award of contract, a vendor representative was onsite early in the project to help with engineering efforts and procedures. This aided greatly in completing preparations for the decontamination. (3) The work was performed under a single maintenance activity. This resulted in great craft and plant support. (4) The constant coverage by the site's decontamination flush directors provided timely plant support and interface. (5) The FPC system isolation and back flushing to prevent residual chemicals from being left in the FPC system should have been addressed in more detail in the pre-engineering study to prevent delays during the final system cleanup.« less
Sawano, Toyoaki; Tsubokura, Masaharu; Ozaki, Akihiko; Leppold, Claire; Kato, Shigeaki; Kambe, Toshiyuki
2018-05-25
Legionnaires' disease (LD), which is atypical pneumonia with a broad variety of clinical symptoms, can lead to death despite its low incidence. There are multiple risk factors for LD, yet little information is available concerning what kind of environmental factors are linked to higher risk of LD development. We have experienced a fatal case of LD, which occurred in a decontamination worker after the Fukushima nuclear disaster. A 53-year-old Japanese male visited our hospital with symptoms of fever, vomiting, diarrhea, and altered mental status, but not with respiratory manifestations. He was engaged in decontamination work, which generally includes operations such as the removal of topsoil in mountainous areas and cleaning roads and roofs of residential buildings with high-pressure water. He was required to wear specific equipment to prevent radiation exposure, and lived in a workers' dormitory or shared house, thereby sharing spaces with other workers. Normal antibiotic therapy did not improve his symptoms following his diagnosis with pneumonia. A urinary antigen detection test was then conducted, leading to a diagnosis of LD. Despite the change of antibiotic to levofloxacin, multiple organ failure led to his death. Decontamination workers may be at a high risk for developing LD and living and working conditions among them are possible contributors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meservey, A.B.
1963-01-01
A search for solutions suitable for dissolving uranium dioxide powder or lumps and yet noncorrosive enough to be used for decontaminating the carbon steel EGCR charge and service machines resulted in the development of buffered oxalate solutions of controlled temperature and pH, with hydrogen peroxide added to act as corrosion inhibitor, UO/sub 2/ oxidizer, and decontamination aid. Hydrogen peroxide acts either as a corrosion promoter or inhibitor, depending on factors such as its concentration, the ratio to other ingredients, acidity, temperature, the presence of complexing agents, and the ferric ion content of the solution. In general, oxalate-peroxide solutions for fissionmore » product decontamination from metal surfaces were superior to more conventional decontaminating solutions and had attractively low corrosion rates on carbon steel (less than 0.01 mil/hr), Solution instability, initially a serious drawback, was largely overcome. Of nearly a hundred formulations studied, the one having the best combination of long life, low corrosivity, high solvency for UO/sub 2/, decontamination power, safety, and ease of waste disposal was an aqueous solution of 0.4M oxalic acid, 0.18M ammonium citrate, and 0.34M H/sub 2/O/sub 2/, adjusted to pH 4.00 with ammonium hydroxide and used at 85 to 95 deg C. Similar solutions at lower pH, with increased H/sub 2/O/sub 2/ concentration to maintain noncorrosiveness, were successful decontaminants at 60 deg C when contact times were increased to several hours. Contaminated stainless steels heated to 500 deg C in helium resisted decontamination in noncorrosive reagents. Oxalate-peroxide soluttons are currently recommended as UO/sub 2/ solvents and as general decontaminants for mild steel and aluminum surfaces in the GCR program, and for stainless steels which were not strongly heated while contaminated. These solutions may also find application in the decontamination of metals used in the aqueous reprocessing of radioactive nuclear fuels. (auth)« less
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Context: Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. Aim: To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Settings and Design: Lab-simulated working surface materials. Experimental study design. Materials and Methods: Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Statistical Analysis: Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Results: Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Conclusions: Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area. PMID:28680198
Lomash, Vinay; Pant, Satish C
2014-01-01
Sulfur mustard (SM)-induced dermatotoxicity can be prevented by an immediate use of decontamination agents. However, practically due to the time lapse between decontamination and exposure, there is always a possibility of wound formation. In view of this, a hydrophilic decontamination formulation of CC-2 (DRDE/WH-03) was fortified with Aloe vera gel and betaine (DRDE/WH-01) for improving its wound healing ability. Swiss albino mice were exposed to SM percutaneously (5 mg/kg) once, and after 24 hours, DRDE/WH-01, DRDE/WH-03, framycetin, and aloe gel were applied topically, daily for 7 days. Skin sections were subjected to histopathology, histomorphologic grading, tissue leukocytosis, and immunohistochemistry of inflammatory-reparative biomarkers on 3 and 7 days, respectively. DRDE/WH-01, framycetin, and aloe gel showed better reepithelialization, angiogenesis, and fibroplasia compared with DRDE/WH-03 and SM control. On the basis of histomorphologic scale, DRDE/WH-01, framycetin, and aloe gel were found to be equally efficacious. Up-regulation of interleukin-6 and infiltrating leukocytes, endothelial nitric oxide synthase and angiogenesis, fibroblast growth factor, and transforming growth factor-alpha with fibroplasia and reepithelialization were well correlated at various stages of the healing process. DRDE/WH-01 was equally effective as framycetin and has shown improved wound healing efficacy compared with DRDE/WH-03. Thus, DRDE/WH-01 can be recommended as a universal decontaminant and wound healant against vesicant-induced skin injury. © 2014 by the Wound Healing Society.
Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan
2012-01-01
Background: A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean® technology, based on anodic oxidation. Method: The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean® (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. Results: After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean® was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. Discussion: An important factor for the efficacy of PotoClean® was the age of the units and their construction. For a new generation of dental units PotoClean® was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. Conclusion: The PotoClean® technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean® and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable. PMID:22558044
Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan
2012-01-01
A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean(®) (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean(®) was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. An important factor for the efficacy of PotoClean(®) was the age of the units and their construction. For a new generation of dental units PotoClean(®) was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. The PotoClean(®) technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean(®) and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable.
[Advances in peroxide-based decontaminating technologies].
Xi, Hai-ling; Zhao, San-ping; Zhou, Wen
2013-05-01
With the boosting demand for eco-friendly decontaminants, great achievements in peroxide-based decontaminating technologies have been made in recent years. These technologies have been applied in countering chemical/biological terrorist attacks, dealing with chemical/biological disasters and destructing environmental pollutants. Recent research advances in alpha-nucleophilic/oxidative reaction mechanisms of peroxide-based decontamination against chemical warfare agents were reviewed, and some classical peroxide-based decontaminants such as aqueous decontaminating solution, decontaminating foam, decontaminating emulsions, decontaminating gels, decontaminating vapors, and some newly developed decontaminating media (e.g., peroxide-based self-decontaminating materials and heterogeneous nano-catalytic decontamination systems) were introduced. However, currently available peroxide-based decontaminants still have some deficiencies. For example, their decontamination efficiencies are not as high as those of chlorine-containing decontaminants, and some peroxide-based decontaminants show relatively poor effect against certain agents. More study on the mechanisms of peroxide-based decontaminants and the interfacial interactions in heterogeneous decontamination media is suggested. New catalysts, multifunctional surfactants, self-decontaminating materials and corrosion preventing technologies should be developed before peroxide-based decontaminants really become true "green" decontaminants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L.; Martin, K.; Hobbs, D.
2011-05-26
This report describes experimental results for the selective removal of strontium and cesium from simulated waste solutions using monosodium titanate (MST) and crystalline silicotitanate (CST)-laden filter cartridges. Four types of ion exchange cartridge media (CST and MST designed by both 3M and POROX{reg_sign}) were evaluated. In these proof-of-principle tests effective uptake of both Sr-85 and Cs-137 was observed. However, the experiments were not performed long enough to determine the saturation levels or breakthrough curve for each filter cartridge. POREX{reg_sign} MST cartridges, which by design were based on co-sintering of the active titanates with polyethylene particles, seem to perform as wellmore » as the 3M-designed MST cartridges (impregnated filter membrane design) in the uptake of strontium. At low salt simulant conditions (0.29 M Na{sup +}), the instantaneous decontamination factor (D{sub F}) for Sr-85 with the 3M-design MST cartridge measured 26, representing the removal of 96% of the Sr-85. On the other hand, the Sr-85 instantaneous D{sub F} with the POREX{reg_sign} design MST cartridge measured 40 or 98% removal of the Sr-85. Strontium removal with the 3M-design MST and CST cartridges placed in series filter arrangement produced an instantaneous decontamination factor of 41 or 97.6% removal compared to an instantaneous decontamination factor of 368 or 99.7% removal of the strontium with the POREX{reg_sign} MST and CST cartridge design placed in series. At high salt simulant conditions (5.6 M Na{sup +}), strontium removal with 3M-designed MST cartridge only and with 3M-designed MST and CST cartridges operated in a series configuration were identical. The instantaneous decontamination factor and the strontium removal efficiency, under the above configuration, averaged 8.6 and 88%, respectively. There were no POREX{reg_sign} cartridge experiments using the higher ionic strength simulant solution. At low salt simulant conditions, the uptake of Cs-137 with POREX{reg_sign} CST cartridge out performed the 3M-designed CST cartridges. The POREX{reg_sign} CST cartridge, with a Cs-137 instantaneous decontamination factor of 55 and a Cs-137 removal efficiency of 98% does meet the Cs-137 decontamination goals in the low salt simulant liquor. The Cs-137 removal with 3M-designed CST cartridge produced a decontamination factor of 2 or 49% removal efficiency. The Cs-137 performance graph for the 3M-designed CST cartridge showed an early cessation in the uptake of cesium-137. This behavior was not observed with the POREX{reg_sign} CST cartridges. No Cs-137 uptake tests were performed with the POREX{reg_sign} CST cartridges at high salt simulant conditions. The 3M-designed CST cartridges, with an instantaneous Cs-137 decontamination factor of less than 3 and a Cs-137 removal efficiency of less than 50% failed to meet the Cs-137 decontamination goals in both the low and high salt simulant liquors. This poor performance in the uptake of Cs-137 by the 3M CST cartridges may be attributed to fabrication flaws for the 3M-designed CST cartridges. The reduced number of CST membrane wraps per cartridge during the cartridge design phase, from 3-whole wraps to about 1.5, may have contributed to Cs-137 laden simulant channeling/by-pass which led to the poor performance in terms of Cs-137 sorption characteristics for the 3M designed CST cartridges. The grinding of CST ion exchange materials, to reduce the particle size distribution and thus enhance their easy incorporation into the filter membranes and the co-sintering of MST with polyethylene particles, did not adversely affect the sorption kinetics of both CST and MST in the uptake of Cs-137 and Sr-85, respectively. In general, the POREX{reg_sign} based cartridges showed more resistance to simulant flow through the filter cartridges as evidenced by higher pressure differences across the cartridges. Based on these findings they conclude that incorporating MST and CST sorbents into filter membranes represent a promising method for the semi-continuous removal of radioisotopes of strontium and cesium from waste solutions.« less
McGann, Christopher L; Daniels, Grant C; Giles, Spencer L; Balow, Robert B; Miranda-Zayas, Jorge L; Lundin, Jeffrey G; Wynne, James H
2018-06-01
The threat of chemical warfare agents (CWA) compels research into novel self-decontaminating materials (SDM) for the continued safety of first-responders, civilians, and active service personnel. The capacity to actively detoxify, as opposed to merely sequester, offending agents under typical environmental conditions defines the added value of SDMs in comparison to traditional adsorptive materials. Porous polymers, synthesized via the high internal phase emulsion (HIPE) templating, provide a facile fabrication method for materials with permeable open cellular structures that may serve in air filtration applications. PolyHIPEs comprising polydicyclopentadiene (polyDCPD) networks form stable hydroperoxide species following activation in air under ambient conditions. The hydroperoxide-containing polyDCPD materials react quickly with CWA simulants, Demeton-S and 2-chloroethyl ethyl sulfide, forming oxidation products as confirmed via gas chromatography mass spectrometry. The simplicity of the detoxification chemistry paired with the porous foam form factor presents an exciting opportunity for the development of self-decontaminating filter media. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Browns Ferry Nuclear Plant Unit 2: Control rod drive scram discharge headers decontamination effort
DOE Office of Scientific and Technical Information (OSTI.GOV)
Traynor, J.C.
1983-08-01
The control rod drive (CRD) scram discharge headers were decontaminated during the Browns Ferry unit 2, cycle 4 refueling outage (August 2-5, 1982). Hydrolasing (high-pressure water blasting) was used as the method of decontamination to remove fixed and loose radioactive contaminants from the headers. It was found that hydrolasing of the west scram discharge headers resulted in approximate maximum and average decontamination factors (DFs) on contact of 13 and 5, respectively. For the east scram discharge headers, hydrolasing resulted in a maximum and average DF on contact of approximately 3. The maximum and average DFs on contact for the individualmore » headers ranged from 1 to 33 and 1 to 10, respectively, while the walkway (head-level) DFs were in the range of 3 to 4. Higher DFs were impeded by inadequate drainage and backwashing of fluid. This led to increased radiation levels in some areas and recontamination of adjacent headers.« less
Prevention of Infection Due to Clostridium difficile.
Cooper, Christopher C; Jump, Robin L P; Chopra, Teena
2016-12-01
Clostridium difficile is one of the foremost nosocomial pathogens. Preventing infection is particularly challenging. Effective prevention efforts typically require a multifaceted bundled approach. A variety of infection control procedures may be advantageous, including strict hand decontamination with soap and water, contact precautions, and using chlorine-containing decontamination agents. Additionally, risk factor reduction can help reduce the burden of disease. The risk factor modification is principally accomplished though antibiotic stewardship programs. Unfortunately, most of the current evidence for prevention is in acute care settings. This review focuses on preventative approaches to reduce the incidence of Clostridium difficile infection in healthcare settings. Copyright © 2016 Elsevier Inc. All rights reserved.
Ray, Amy; Perez, Federico; Beltramini, Amanda M; Jakubowycz, Marta; Dimick, Patricia; Jacobs, Michael R; Roman, Kathy; Bonomo, Robert A; Salata, Robert A
2010-12-01
To describe vaporized hydrogen peroxide (VHP) as an adjuvant in the control of multidrug-resistant (MDR) Acinetobacter baumannii infection in a long-term acute care hospital (LTACH) and to describe the risk factors for acquisition of MDR A. baumannii infection in the LTACH population. Outbreak investigation, case-control study, and before-after intervention trial. A 54-bed LTACH affiliated with a tertiary care center in northeastern Ohio. Investigation of outbreak with clinical and environmental cultures, antimicrobial susceptibility testing, polymerase chain reaction assay of repetitive chromosomal elements to type strains, and case-control study; and intervention consisting of comprehensive infection control measures and VHP environmental decontamination. Thirteen patients infected or colonized with MDR A. baumannii were identified from January 2008 through June 2008. By susceptibility testing, 10 (77%) of the 13 isolates were carbapenem-resistant. MDR A. baumannii was found in wound samples, blood, sputum, and urine. Wounds were identified as a risk factor for MDR A. baumannii colonization. Ventilator-associated pneumonia was the most common clinical syndrome caused by the pathogen, and the associated mortality was 14% (2 of the 13 case patients died). MDR A. baumannii was found in 8 of 93 environmental samples, including patient rooms and a wound care cart; environmental and clinical cultures were genetically related. Environmental cultures were negative immediately after VHP decontamination and both 24 hours and 1 week after VHP decontamination. Nosocomial acquisition of the pathogen in the LTACH ceased after VHP intervention. When patients colonized with MDR A. baumannii reoccupied rooms, environmental contamination recurred. Environmental decontamination using VHP combined with comprehensive infection control measures interrupted nosocomial transmission of MDR A. baumannii in an LTACH. The application of this novel approach to halt the transmission of MDR A. baumannii warrants further investigation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... with the particular spill. These factors may mitigate expected exposures and risks or make cleanup to... spill situations in which site-specific risk factors may warrant additional cleanup to more stringent... numerical decontamination levels is clearly unwarranted because of risk-mitigating factors, that compliance...
Code of Federal Regulations, 2011 CFR
2011-07-01
... with the particular spill. These factors may mitigate expected exposures and risks or make cleanup to... spill situations in which site-specific risk factors may warrant additional cleanup to more stringent... numerical decontamination levels is clearly unwarranted because of risk-mitigating factors, that compliance...
1982-08-01
results of changing selected independent variables. ri The results of the projection of chemical agent density and cloud drift, including dissapation and... combination of agent effects, creates, over time, an extensive threat to wide areas of the FBHA, according to current theories. Shifting wind patterns...will be proposed in paragraph 2.7. The selection of decontamination equipment by the study team is a result of a combination of factors. First, current
Endo, Shota; Kakamu, Takeyasu; Sato, Sei; Hidaka, Tomoo; Kumagai, Tomohiro; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2017-09-28
The aim of this study was to reveal the current state of preventive measures and lifestyle habits against heat illness in radiation decontamination workers and to examine whether young radiation decontamination workers take less preventive measures and have worse lifestyle habits than the elder workers. This was a cross-sectional study. Self-administered questionnaires were sent to 1,505 radiation decontamination workers in Fukushima, Japan. Five hundred fifty-eight men who replied and answered all questions were included in the statistical analysis. The questionnaire included age, duration of decontamination work, previous occupation, lifestyle habit, and preventive measures for heat illness. We classified age of the respondents into five groups: <30, 30-39, 40-49, 50-59, and ≥60 years and defined the workers under 30 years of age as young workers. Logistic regression analysis was used to reveal the factors associated with each lifestyle habit and preventive measures. In comparison with young workers, 50-59-year-old workers were significantly associated with refraining from drinking alcohol. Workers 40 years of age or older were significantly associated with cooling their bodies with refrigerant. Furthermore, 30-39-year-old workers and 40-49-year-old workers were significantly associated with adequate consumption of water compared to young workers. The results of our study suggests that young decontamination workers are more likely to have worse lifestyle habits and take insufficient preventive measures for heat illness. This may be the cause of higher incidence of heat illness among young workers.
Sawano, Toyoaki; Tsubokura, Masaharu; Ozaki, Akihiko; Leppold, Claire; Kato, Shigeaki; Kambe, Toshiyuki
2017-01-01
Objectives: Legionnaires' disease (LD), which is atypical pneumonia with a broad variety of clinical symptoms, can lead to death despite its low incidence. There are multiple risk factors for LD, yet little information is available concerning what kind of environmental factors are linked to higher risk of LD development. We have experienced a fatal case of LD, which occurred in a decontamination worker after the Fukushima nuclear disaster. Case: A 53-year-old Japanese male visited our hospital with symptoms of fever, vomiting, diarrhea, and altered mental status, but not with respiratory manifestations. He was engaged in decontamination work, which generally includes operations such as the removal of topsoil in mountainous areas and cleaning roads and roofs of residential buildings with high-pressure water. He was required to wear specific equipment to prevent radiation exposure, and lived in a workers' dormitory or shared house, thereby sharing spaces with other workers. Normal antibiotic therapy did not improve his symptoms following his diagnosis with pneumonia. A urinary antigen detection test was then conducted, leading to a diagnosis of LD. Despite the change of antibiotic to levofloxacin, multiple organ failure led to his death. Conclusion: Decontamination workers may be at a high risk for developing LD and living and working conditions among them are possible contributors. PMID:29311436
Treatment of radioactive liquid waste by sorption on natural zeolite in Turkey.
Osmanlioglu, Ahmet Erdal
2006-09-01
Liquid radioactive waste has been generated from the use of radioactive materials in industrial applications, research and medicine in Turkey. Natural zeolites (clinoptilolite) have been studied for the removal of several key radionuclides ((137)Cs, (60)Co, (90)Sr and (110m)Ag) from liquid radioactive waste. The aim of the present study is to investigate effectiveness of zeolite treatment on decontamination factor (DF) in a combined process (chemical precipitation and adsorption) at the laboratory tests and scale up to the waste treatment plant. In this study, sorption and precipitation techniques were adapted to decontamination of liquid low level waste (LLW). Effective decontamination was achieved when sorbents are used during the chemical precipitation. Natural zeolite samples were taken from different zeolite formations in Turkey. Comparison of the ion-exchange properties of zeolite minerals from different formations shows that Gordes clinoptilolite was the most suitable natural sorbent for radionuclides under dynamic treatment conditions and as an additive for chemical precipitation process. Clinoptilolite were shown to have a high selectivity for (137)Cs and (110m)Ag as sorbent. In the absence of potassium ions, native clinoptilolite removed (60)Co and (90)Sr very effectively from the liquid waste. In the end of this liquid waste treatment, decontamination factor was provided as 430 by using 0.5 mm clinoptilolite at 30 degrees C.
Development of a universal solvent for the decontamination of acidic liquid radioactive wastes
NASA Astrophysics Data System (ADS)
Todd, T. A.; Brewer, K. N.; Law, J. D.; Wood, D. J.; Herbest, R. S.; Romanovskiy, V. N.; Esimantovskiy, V. M.; Smirnov, I. V.; Babain, V. A.
1999-01-01
A teritiary solvent containing chlorinated cobalt dicarbollide, polyethylene glycol and diphenylcarbamoylmethylphosphine oxide was evaluated in different non-nitroaromatic diluents for the separation of cesium, strontium, actinides and rare earth elements from acidic liquid radioactive waste. Decontamination factors of >95% for Cs, 99.7% for Sr, and 99.99% for actinides were achieved in four successive batch contacts using actual radioactive waste. Pilot plant testing in centrifugal contactors using simulated wastes, has demonstrated removal of >99% of all targeted ions.
Birnbaum, Eva R.; Bene, Balazs J.; Taylor, Wayne Allen; ...
2016-06-04
Here, this paper discusses the development of a separation method for isolation of Tm-171 from a half-gram irradiated erbium target in support of stockpile stewardship and astrophysics research. The developed procedure is based on cation exchange separation using alpha-hydroxyisobutyric acid (α-HIBA) as chelating agent. It is able to achieve either a decontamination factor of 1.4(4) × 10 5 with 68.9(3) % recovery or 95.4(3) % recovery with a decontamination factor of 5.82(7) × 10 3 for a mock 500-mg target containing 17.9 mg thulium in a single pass-through at room temperature.
Endo, Shota; Kakamu, Takeyasu; Sato, Sei; Hidaka, Tomoo; Kumagai, Tomohiro; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2017-01-01
Objectives: The aim of this study was to reveal the current state of preventive measures and lifestyle habits against heat illness in radiation decontamination workers and to examine whether young radiation decontamination workers take less preventive measures and have worse lifestyle habits than the elder workers. Methods: This was a cross-sectional study. Self-administered questionnaires were sent to 1,505 radiation decontamination workers in Fukushima, Japan. Five hundred fifty-eight men who replied and answered all questions were included in the statistical analysis. The questionnaire included age, duration of decontamination work, previous occupation, lifestyle habit, and preventive measures for heat illness. We classified age of the respondents into five groups: <30, 30-39, 40-49, 50-59, and ≥60 years and defined the workers under 30 years of age as young workers. Logistic regression analysis was used to reveal the factors associated with each lifestyle habit and preventive measures. Results: In comparison with young workers, 50-59-year-old workers were significantly associated with refraining from drinking alcohol. Workers 40 years of age or older were significantly associated with cooling their bodies with refrigerant. Furthermore, 30-39-year-old workers and 40-49-year-old workers were significantly associated with adequate consumption of water compared to young workers. Conclusion: The results of our study suggests that young decontamination workers are more likely to have worse lifestyle habits and take insufficient preventive measures for heat illness. This may be the cause of higher incidence of heat illness among young workers. PMID:28794393
Spiandore, Marie; Piram, Anne; Lacoste, Alexandre; Prevost, Philippe; Maloni, Pascal; Torre, Franck; Asia, Laurence; Josse, Denis; Doumenq, Pierre
2017-04-01
Chemical warfare agents are an actual threat and victims' decontamination is a main concern when mass exposure occurs. Skin decontamination with current protocols has been widely documented, as well as surface decontamination. However, considering hair ability to trap chemicals in vapour phase, we investigated hair decontamination after exposure to sulphur mustard simulants methyl salicylate and 2-chloroethyl ethyl sulphide. Four decontamination protocols were tested on hair, combining showering and emergency decontamination (use of Fuller's earth or Reactive Skin Decontamination Lotion RSDL ® ). Both simulants were recovered from hair after treatment, but contents were significantly reduced (42-85% content allowance). Showering alone was the least efficient protocol. Concerning 2-chloroethyl ethyl sulphide, protocols did not display significant differences in decontamination efficacy. For MeS, use of emergency decontaminants significantly increased showering efficacy (10-20% rise), underlining their usefulness before thorough decontamination. Our results highlighted the need to extensively decontaminate hair after chemical exposure. Residual amounts after decontamination are challenging, as their release from hair could lead to health issues. Copyright © 2016. Published by Elsevier B.V.
Ray, Amy; Perez, Federico; Beltramini, Amanda M.; Jakubowycz, Marta; Dimick, Patricia; Jacobs, Michael R.; Roman, Kathy; Bonomo, Robert A.; Salata, Robert A.
2013-01-01
OBJECTIVES To describe vaporized hydrogen peroxide (VHP) as an adjuvant in the control of multidrug-resistant (MDR) Acinetobacter baumannii infection in a long-term acute care hospital (LTACH) and to describe the risk factors for acquisition of MDR A. baumannii infection in the LTACH population. DESIGN Outbreak investigation, case-control study, and before-after intervention trial. SETTING A 54-bed LTACH affiliated with a tertiary care center in northeastern Ohio. METHODS Investigation of outbreak with clinical and environmental cultures, antimicrobial susceptibility testing, polymerase chain reaction assay of repetitive chromosomal elements to type strains, and case-control study; and intervention consisting of comprehensive infection control measures and VHP environmental decontamination. RESULTS Thirteen patients infected or colonized with MDR A. baumannii were identified from January 2008 through June 2008. By susceptibility testing, 10 (77%) of the 13 isolates were carbapenem-resistant. MDR A. baumannii was found in wound samples, blood, sputum, and urine. Wounds were identified as a risk factor for MDR A. baumannii colonization. Ventilator–associated pneumonia was the most common clinical syndrome caused by the pathogen, and the associated mortality was 14% (2 of the 13 case patients died). MDR A. baumannii was found in 8 of 93 environmental samples, including patient rooms and a wound care cart; environmental and clinical cultures were genetically related. Environmental cultures were negative immediately after VHP decontamination and both 24 hours and 1 week after VHP decontamination. Nosocomial acquisition of the pathogen in the LTACH ceased after VHP intervention. When patients colonized with MDR A. baumannii reoccupied rooms, environmental contamination recurred. CONCLUSION Environmental decontamination using VHP combined with comprehensive infection control measures interrupted nosocomial transmission of MDR A. baumannii in an LTACH. The application of this novel approach to halt the transmission of MDR A. baumannii warrants further investigation. PMID:20973723
Radiocesium decontamination of a riverside in Fukushima, Japan.
Nishikiori, Tatsuhiro; Suzuki, Satoshi
2017-10-01
Extensive decontamination measures have been implemented in the area affected by the Fukushima Dai-ichi nuclear disaster. Typical decontamination measures, such as removing topsoil of several centimeters in depth, are not suitable for rivers where contaminated sediments have been deposited. A decontamination measure was tested that considered the spatial distribution of radiocesium at the lower part of a tributary of the Abukuma River in Fukushima. The radiocesium distribution in the flood channel was vertically and horizontally highly heterogeneous. In some parts, the activity concentration was high (>10 kBq/kg for 137 Cs) even at depths of 25 cm in the sediment. This may be due to plant growth in the flood channel favoring the deposition of sediment with high activity concentration. On the basis of the radiocesium distribution, the flood channel sediment was removed to a depth of 15-35 cm, which accumulated the most radiocesium (>3.0 kBq/kg for the sum of 134 Cs and 137 Cs). The upper 5 cm of soil was removed from the dike slopes. The river bed was not decontaminated because the activity concentration was low (<1 kBq/kg) in the river bed sediment and because the water shields gamma rays emitted from the sediment. The test decontamination measure reduced the air dose rate by a factor of approximately two, demonstrating the effectiveness of our measures. Annual external doses were calculated for when this part of the dike and the flood channel is used for commuting to school and outdoor education. The doses during the activities at the test site accounted for only 1-2% of the value during daily life in the surrounding area, indicating that radiation exposure during riverside activities is limited. Copyright © 2017 Elsevier Ltd. All rights reserved.
Uyttendaele, M; Neyts, K; Vanderswalmen, H; Notebaert, E; Debevere, J
2004-02-01
Aeromonas is an opportunistic pathogen, which, although in low numbers, may be present on minimally processed vegetables. Although the intrinsic and extrinsic factors of minimally processed prepacked vegetable mixes are not inhibitory to the growth of Aeromonas species, multiplication to high numbers during processing and storage of naturally contaminated grated carrots, mixed lettuce, and chopped bell peppers was not observed. Aeromonas was shown to be resistant towards chlorination of water, but was susceptible to 1% and 2% lactic acid and 0.5% and 1.0% thyme essential oil treatment, although the latter provoked adverse sensory properties when applied for decontamination of chopped bell peppers. Integration of a decontamination step with 2% lactic acid in the processing line of grated carrots was shown to have the potential to control the overall microbial quality of the grated carrots and was particularly effective towards Aeromonas.
Microbiological decontamination of natural honey by irradiation
NASA Astrophysics Data System (ADS)
Migdał, W.; Owczarczyk, H. B.; K ȩdzia, B.; Hołderna-K ȩdzia, E.; Madajczyk, D.
2000-03-01
Degree of microbiological decontamination, organoleptic and physico-chemical properties of natural honeys were investigated after radiation treatment. Seven kinds of honeys were irradiated with the beams of 10 MeV electrons from a 10 kW linear accelerator "Elektronika 10-10" at the dose 10 kGy. It was shown, that after irradiation, the total count of aerobic and anaerobic bacteria and moulds decrease by 99%. The antibiotic value in investigated honeys increased in turn from 1.67 to 2.67 after irradiation. Such factors and parameters of investigated honeys as their consistency, content of water and saccharose, acidity, the diastase and 5-HMF values were not changed significantly after irradiation. Decontamination by irradiation is a process which allows us to obtain high microbiological purity of honeys. It is especially needed, when honeys are used in surgical treatment of injuries and in nutrition of babies with food deficiency.
Survival of enterococci during hospital laundry processing.
Orr, K E; Holliday, M G; Jones, A L; Robson, I; Perry, J D
2002-02-01
Much remains to be elucidated about the epidemiology of nosocomial enterococcal infections. Enterococci are, however, known to be relatively thermotolerant, and several studies have shown that under laboratory conditions many strains are able to survive the time/temperature combinations of the UK Department of Health recommendations for the decontamination of used linen (HSG(95)18). We therefore wished to investigate the efficacy of decontamination of enterococci from hospital linen in working hospital laundries. The thermotolerance of 40 strains of Enterococcus faecalis and Enterococcus faecium was first determined. Reduction by a factor of greater than 10(5) was achieved in only two of 40 strains after 3 min at 71 degrees C or 10 min at 65 degrees C, the time/temperature combinations specified by the Department of Health for the disinfection of used linen. During experimental challenge of 10 working hospital laundries, however, we demonstrated successful decontamination of laundry artificially contaminated with enterococci. This was shown to take place during the washing stage. Our study suggests that, despite the relative thermotolerance of enterococci, the time/temperature combinations specified in HSG(95)18 should be adequate for their decontamination in hospital laundries. Copyright 2002 The Hospital Infection Society.
Zuidberg, Matthijs C; van Woerkom, Tiest; de Bruin, Karla G; Stoel, Reinoud D; de Puit, Marcel
2014-01-01
Following a CBRN incident, first responders use decontamination procedures to reduce the risk of exposure. The effect of decontamination on forensic trace material has, however, not been fully examined. This study sought to evaluate the effect of five different physical or chemical decontamination materials on the recovery of latent fingerprints. Fingerprints were deposited on glass slides, decontaminated, and assessed on the presence of ridge detail. The results demonstrate that decontamination affects the quality of latent fingerprints substantially. On at least 61% of the fingerprints, a reduced amount of ridge detail was observed upon decontamination. Furthermore, development with cyanoacrylate appeared not to succeed anymore. Instead, the ability of vacuum metal deposition to successfully develop decontaminated fingerprints is demonstrated. The results from this study may contribute to an increased forensic awareness regarding decontamination and emphasize the necessity for further research into new item decontamination procedures or new forensic initiatives prior to decontamination. © 2013 American Academy of Forensic Sciences.
Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko
2013-01-01
The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans. PMID:24069398
Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko
2013-01-01
The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans.
Tsubokura, Masaharu; Nihei, Masahiko; Sato, Katsumi; Masaki, Shin; Sakuma, Yu; Kato, Shigeaki; Sugimoto, Amina; Nomura, Shuhei; Matsumura, Tomoko; Miyazaki, Makoto; Hayano, Ryugo; Shibuya, Kenji; Kami, Masahiro; Sasaki, Taro
2013-10-01
Decontamination workers may face a high risk of exposure to internal irradiation through inhalation during decontamination activities; there is, however, little previous research on the levels of internal contamination during decontamination procedures. The authors reviewed the medical records, including whole body counter measurements, of decontamination workers in villages near the crippled Fukushima Daiichi Nuclear Power Plant to assess their levels of internal radiation exposure. In total, 83 decontamination workers were enrolled in this study. They were regularly engaged in decontamination activities in highly contaminated areas where surface 137Cs deposition density was over 100 kBq m-2. The present study showed low levels of internal exposure among the decontamination workers near the Fukushima Daiichi nuclear plant. The cesium burdens of all the decontamination workers were below detection limits. They had reported no acute health problems. The resuspension of radioactive materials may cause minimal internal contamination during decontamination activities.
Lessons Learned from Decontamination Experiences
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorensen, JH
2000-11-16
This interim report describes a DOE project currently underway to establish what is known about decontamination of buildings and people and the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who weremore » decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less
Thors, L; Koch, M; Wigenstam, E; Koch, B; Hägglund, L; Bucht, A
2017-08-01
The decontamination efficacy of four commercially available skin decontamination products following exposure to the nerve agent VX was evaluated in vitro utilizing a diffusion cell and dermatomed human skin. The products included were Reactive Skin Decontamination Lotion (RSDL), the Swedish decontamination powder 104 (PS104), the absorbent Fuller's Earth and the aqueous solution alldecontMED. In addition, various decontamination procedures were assessed to further investigate important mechanisms involved in the specific products, e.g. decontamination removal from skin, physical removal by sponge swabbing and activation of degradation mechanisms. The efficacy of each decontamination product was evaluated 5 or 30 min after dermal application of VX (neat or diluted to 20% in water). The RSDL-lotion was superior in reducing the penetration of VX through human skin, both when exposed as neat agent and when diluted to 20% in water. Swabbing with the RSDL-sponge during 2 min revealed decreased efficacy compared to applying the RSDL-lotion directly on the skin for 30 min. Decontamination with Fuller's Earth and alldecontMED significantly reduced the penetration of neat concentration of VX through human skin. PS104-powder was insufficient for decontamination of VX at both time-points, independently of the skin contact time of PS104. The PS104-slurry (a mixture of PS104-powder and water), slightly improved the decontamination efficacy. Comparing the time-points for initiated decontamination revealed less penetrated VX for RSDL and Fuller's Earth when decontamination was initiated after 5 min compared to 30 min post-exposure, while alldecontMED displayed similar efficacy at both time-points. Decontamination by washing with water only resulted in a significant reduction of penetrated VX when washing was performed 5 min after exposure, but not when decontamination was delayed to 30 min post-exposure of neat VX. In conclusion, early initiated decontamination with the RSDL-lotion, containing both absorption and degrading properties, allowed to act on skin for 30 min was superior in preventing VX from penetrating human skin. Adding water during decontamination resulted in increased penetration of neat VX, however, water in the decontaminant removal process did not influence the decontamination efficacy. From our study on commercially available decontaminants, it is recommended that future product developments should include both strong absorbents and efficient nerve agent degrading components. Copyright © 2017 Elsevier B.V. All rights reserved.
Biochemical process of low level radioactive liquid simulation waste containing detergent
NASA Astrophysics Data System (ADS)
Kundari, Noor Anis; Putra, Sugili; Mukaromah, Umi
2015-12-01
Research of biochemical process of low level radioactive liquid waste containing detergent has been done. Thse organic liquid wastes are generated in nuclear facilities such as from laundry. The wastes that are cotegorized as hazard and poison materials are also radioactive. It must be treated properly by detoxification of the hazard and decontamination of the radionuclides to ensure that the disposal of the waste meets the requirement of standard quality of water. This research was intended to determine decontamination factor and separation efficiensies, its kinetics law, and to produce a supernatant that ensured the environmental quality standard. The radioactive element in the waste was thorium with activity of 5.10-5 Ci/m3. The radioactive liquid waste which were generated in simulation plant contains detergents that was further processed by aerobic biochemical process using SGB 103 bacteria in a batch reactor equipped with aerators. Two different concentration of samples were processed and analyzed for 212 hours and 183 hours respectively at a room temperature. The product of this process is a liquid phase called as supernatant and solid phase material called sludge. The chemical oxygen demand (COD), biological oxygen demand (BOD), suspended solid (SS), and its alpha activity were analyzed. The results show that the decontamination factor and the separation efficiency of the lower concentration samples are higher compared to the samples with high concentration. Regarding the decontamination factor, the result for 212 hours processing of waste with detergent concentration of 1.496 g/L was 3.496 times, whereas at the detergent concentration of 0.748 g/L was 15.305 times for 183 hours processing. In case of the separation efficiency, the results for both samples were 71.396% and 93.465% respectively. The Bacterial growth kinetics equation follow Monod's model and the decreasing of COD and BOD were first order with the rate constant of 0.01 hour-1.
Biochemical process of low level radioactive liquid simulation waste containing detergent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kundari, Noor Anis, E-mail: nooranis@batan.go.id; Putra, Sugili; Mukaromah, Umi
Research of biochemical process of low level radioactive liquid waste containing detergent has been done. Thse organic liquid wastes are generated in nuclear facilities such as from laundry. The wastes that are cotegorized as hazard and poison materials are also radioactive. It must be treated properly by detoxification of the hazard and decontamination of the radionuclides to ensure that the disposal of the waste meets the requirement of standard quality of water. This research was intended to determine decontamination factor and separation efficiensies, its kinetics law, and to produce a supernatant that ensured the environmental quality standard. The radioactive elementmore » in the waste was thorium with activity of 5.10{sup −5} Ci/m{sup 3}. The radioactive liquid waste which were generated in simulation plant contains detergents that was further processed by aerobic biochemical process using SGB 103 bacteria in a batch reactor equipped with aerators. Two different concentration of samples were processed and analyzed for 212 hours and 183 hours respectively at a room temperature. The product of this process is a liquid phase called as supernatant and solid phase material called sludge. The chemical oxygen demand (COD), biological oxygen demand (BOD), suspended solid (SS), and its alpha activity were analyzed. The results show that the decontamination factor and the separation efficiency of the lower concentration samples are higher compared to the samples with high concentration. Regarding the decontamination factor, the result for 212 hours processing of waste with detergent concentration of 1.496 g/L was 3.496 times, whereas at the detergent concentration of 0.748 g/L was 15.305 times for 183 hours processing. In case of the separation efficiency, the results for both samples were 71.396% and 93.465% respectively. The Bacterial growth kinetics equation follow Monod’s model and the decreasing of COD and BOD were first order with the rate constant of 0.01 hour{sup −1}.« less
Kaminski, Michael D; Lee, Sang Don; Magnuson, Matthew
2016-03-15
Nuclear or radiological terrorism in the form of uncontrolled radioactive contamination presents a unique challenge in the field of nuclear decontamination. Potential targets require an immediate decontamination response, or mitigation plan to limit the social and economic impact. To date, experience with urban decontamination of building materials - specifically hard, porous, external surfaces - is limited to nuclear weapon fallout and nuclear reactor accidents. Methods are lacking for performing wide-area decontamination in an urban environment so that in all release scenarios the area may be re-occupied without evaluation and/or restriction. Also lacking is experience in developing mitigation strategies, that is, methods of mitigating contamination and its resultant radiation dose in key areas during the immediate aftermath of an event and after lifesaving operations. To date, the tremendous strategy development effort primarily by the European community has focused on the recovery phase, which extends years beyond the release event. In this review, we summarize the methods and data collected over the past 70 years in the field of hard, external surface decontamination of radionuclide contaminations, with emphasis on methods suitable for response to radiological dispersal devices and their potentially unique physico-chemical characteristics. This review concludes that although a tremendous amount of work has been completed primarily by the European Community (EU) and the United Kingdom (UK), the few studies existing on each technique permit only very preliminary estimates of decontamination factors for various building materials and methods and extrapolation of those values for use in environments outside the EU and UK. This data shortage prevents us from developing an effective and detailed mitigation response plan and remediation effort. Perhaps most importantly, while the data available does include valuable information on the practical aspects of performing the various remediation methods including costs, coverage rates, manpower, pitfalls, etc., it lacks the details on lessons learned, best practices, and standard procedures, for instance, that would be required to develop a mitigation strategy. While the urban decontamination problem is difficult and there is much more research to do, the existing literature provides a framework for a response plan. Using this framework, in conjunction with computer modeling and relevant data collection, can lead to development of appropriate plans and exercises that would permit development of a mitigation and remediation response. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogt
This report describes a U.S. Department of Energy, (DOE) Chemical and Biological National Security Program project that sought to establish what is known about decontamination of structures, objects, and people following an exposure to chemical or biological materials. Specifically we sought to identify the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the factorsmore » determining when people were (or were not) decontaminated, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wille, H.; Bertholdt, H.O.; Operschall, H.
Efforts to reduce occupational radiation exposure during inspection and repair work in nuclear power plants turns steadily increasing attention to the decontamination of systems and components. Due to the advanced age of nuclear power plants resulting in increasing dose rates, the decontamination of components, or rather of complete systems, or loops to protect operating and inspection personnel becomes demanding. Besides, decontaminating complete primary loops is in many cases less difficult than cleaning large components. Based on experience gained in nuclear power plants, an outline of two different decontamination methods performed recently are given. For the decontamination of complete systems ormore » loops, Kraftwerk Union AG has developed CORD, a low-concentration process. For the decontamination performance of a subsystem, such as the steam generator (SG) channel heads of a pressurized water reactor or the recirculation loops of a boiling water reactor the automated mobile decontamination appliance is used. The electrochemical decontamination process is primarily applicable for the treatment of specially limited surface areas.« less
Mass Casualty Decontamination in the United States: An Online Survey of Current Practice
Power, Sarah; Symons, Charles; Carter, Holly; Jones, Emma; Larner, Joanne; Matar, Hazem; Chilcott, Robert P.
2016-01-01
Mass casualty decontamination is a public health intervention that would be employed by emergency responders following a chemical, biological, or radiological incident. The decontamination of large numbers of casualties is currently most often performed with water to remove contaminants from the skin surface. An online survey was conducted to explore US fire departments' decontamination practices and their preparedness for responding to incidents involving mass casualty decontamination. Survey respondents were asked to provide details of various aspects of their decontamination procedures, including expected response times to reach casualties, disrobing procedures, approaches to decontamination, characteristics of the decontamination showering process, provision for special populations, and any actions taken following decontamination. The aim of the survey was to identify any differences in the way in which decontamination guidance is implemented across US states. Results revealed that, in line with current guidance, many US fire departments routinely use the “ladder-pipe system” for conducting rapid, gross decontamination of casualties. The survey revealed significant variability in ladder-pipe construction, such as the position and number of fire hoses used. There was also variability in decontamination characteristics, such as water temperature and water pressure, detergent use, and shower duration. The results presented here provide important insights into the ways in which implementation of decontamination guidance can vary between US states. These inconsistencies are thought to reflect established perceived best practices and local adaptation of response plans to address practical and logistical constraints. These outcomes highlight the need for evidence-based national guidelines for conducting mass casualty decontamination. PMID:27442794
Studies on residue-free decontaminants for chemical warfare agents.
Wagner, George W
2015-03-17
Residue-free decontaminants based on hydrogen peroxide, which decomposes to water and oxygen in the environment, are examined as decontaminants for chemical warfare agents (CWA). For the apparent special case of CWA on concrete, H2O2 alone, without any additives, effectively decontaminates S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate (VX), pinacolyl methylphosphorofluoridate (GD), and bis(2-choroethyl) sulfide (HD) in a process thought to involve H2O2 activation by surface-bound carbonates/bicarbonates (known H2O2 activators for CWA decontamination). A plethora of products are formed during the H2O2 decontamination of HD on concrete, and these are characterized by comparison to synthesized authentic compounds. As a potential residue-free decontaminant for surfaces other than concrete (or those lacking adsorbed carbonate/bicarbonate) H2O2 activation for CWA decontamination is feasible using residue-free NH3 and CO2 as demonstrated by reaction studies for VX, GD, and HD in homogeneous solution. Although H2O2/NH3/CO2 ("HPAC") decontaminants are active for CWA decontamination in solution, they require testing on actual surfaces of interest to assess their true efficacy for surface decontamination.
Pickering emulsions for skin decontamination.
Salerno, Alicia; Bolzinger, Marie-Alexandrine; Rolland, Pauline; Chevalier, Yves; Josse, Denis; Briançon, Stéphanie
2016-08-01
This study aimed at developing innovative systems for skin decontamination. Pickering emulsions, i.e. solid-stabilized emulsions, containing silica (S-PE) or Fuller's earth (FE-PE) were formulated. Their efficiency for skin decontamination was evaluated, in vitro, 45min after an exposure to VX, one of the most highly toxic chemical warfare agents. Pickering emulsions were compared to FE (FE-W) and silica (S-W) aqueous suspensions. PE containing an oil with a similar hydrophobicity to VX should promote its extraction. All the formulations reduced significantly the amount of VX quantified on and into the skin compared to the control. Wiping the skin surface with a pad already allowed removing more than half of VX. FE-W was the less efficient (85% of VX removed). The other formulations (FE-PE, S-PE and S-W) resulted in more than 90% of the quantity of VX removed. The charge of particles was the most influential factor. The low pH of formulations containing silica favored electrostatic interactions of VX with particles explaining the better elimination from the skin surface. Formulations containing FE had basic pH, and weak interactions with VX did not improve the skin decontamination. However, these low interactions between VX and FE promote the transfer of VX into the oil droplets in the FE-PE. Copyright © 2016 Elsevier B.V. All rights reserved.
Bergeron, Vance; Chalfine, Annie; Misset, Benoît; Moules, Vincent; Laudinet, Nicolas; Carlet, Jean; Lina, Bruno
2011-05-01
Evidence has recently emerged indicating that in addition to large airborne droplets, fine aerosol particles can be an important mode of influenza transmission that may have been hitherto underestimated. Furthermore, recent performance studies evaluating airborne infection isolation (AII) rooms designed to house infectious patients have revealed major discrepancies between what is prescribed and what is actually measured. We conducted an experimental study to investigate the use of high-throughput in-room air decontamination units for supplemental protection against airborne contamination in areas that host infectious patients. The study included both intrinsic performance tests of the air-decontamination unit against biological aerosols of particular epidemiologic interest and field tests in a hospital AII room under different ventilation scenarios. The unit tested efficiently eradicated airborne H5N2 influenza and Mycobacterium bovis (a 4- to 5-log single-pass reduction) and, when implemented with a room extractor, reduced the peak contamination levels by a factor of 5, with decontamination rates at least 33% faster than those achieved with the extractor alone. High-throughput in-room air treatment units can provide supplemental control of airborne pathogen levels in patient isolation rooms. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Non-destructive decontamination of building materials
NASA Astrophysics Data System (ADS)
Holecek, Josef; Otahal, Petr
2015-11-01
For nondestructive radiation decontamination of surfaces it is necessary to use varnishes, such as ARGONNE, DG1101, DG1108, etc. This text evaluates the use of manufactured strippable coatings for radiation decontamination. To evaluate decontamination capability of such coatings the following varnishes were selected and subsequently used: AZ 1-700 and AXAL 1807S. The varnishes were tested on different building materials surfaces contaminated by short-term radioisotopes of Na-24 or La-140, in water soluble or water insoluble forms. Decontamination quality was assessed by the decontamination efficiency value, defined as the proportion of removed activity to the applied activity. It was found that decontamination efficiency of both used varnishes depends not only on the form of contaminant, but in the case of application of AXAL 1807S varnish it also depends on the method of its application on the contaminated surface. The values of the decontamination efficiency for AZ1-700 varnish range from 46% for decontamination of a soluble form of the radioisotope from concrete surface to 98% for the decontamination of a soluble form of the radioisotope from ceramic tile surface. The decontamination efficiency values determined for AXAL 1807S varnish range from 48% for decontamination of a soluble form of the radioisotope from concrete surface to 96% for decontamination of an insoluble form of the radioisotope from ceramic tile surface. Comparing these values to the values given for the decontaminating varnishes we can conclude that AXAL 1807S varnish is possible to use on all materials, except highly porous materials, such as plasterboard or breeze blocks, or plastic materials. AZ 1-700 varnish can be used for all dry materials except plasterboard.
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Ortiz, John P.
1986-01-01
An apparatus for measuring the overall decontamination factor of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Ortiz, J.P.
1985-07-03
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the apparatus.
An innovative distillation device for tritiated water analysis with high decontamination factor.
Fang, Hsin-Fa; Wang, Chu-Fang; Wang, Jeng-Jong
2013-11-01
Institute of Nuclear Energy Research (INER) has designed an air-cooling distillation device and got a US patent. The decontamination factor (60)Co and (137)Cs is above 23,000. Tritium loss rate is one of testing items in ASTM D4107 Standard Test Method for Tritium in Drinking Water. In this study, the 3 levels (high, middle and low level) of tritium concentration of testing samples for the loss rate test were prepared similar to the concentrations reported in ASTM D4107. The loss rate of the high level is -2.37%, the middle is -2.31% and the low level is -2.47%. These results show that the air-cooling distillation device has good performance in the environmental water tritium analysis work. Copyright © 2013 Elsevier Ltd. All rights reserved.
Bello, Dhimiter; Woskie, Susan R; Streicher, Robert P; Stowe, Meredith H; Sparer, Judy; Redlich, Carrie A; Cullen, Mark R; Liu, Youcheng
2005-07-01
Isocyanates may cause contact dermatitis and respiratory sensitization leading to asthma. Dermal exposure to aliphatic isocyanates in auto body shops is very common. However, little is known about the effectiveness of available commercial products used for decontaminating aliphatic polyisocyanates. This experimental study evaluated the decontamination effectiveness of aliphatic polyisocyanates for several skin and surface decontaminants available for use in the auto body industry. The efficiency of two major decontamination mechanisms, namely (i) consumption of free isocyanate groups via chemical reactions with active hydrogen components of the decontaminant and (ii) physical removal processes such as dissolution were studied separately for each decontaminant. Considerable differences were observed among surface decontaminants in their rate of isocyanate consumption, of which those containing free amine groups performed the best. Overall, Pine-Sol(R) MEA containing monoethanolamine was the most efficient surface decontaminant, operating primarily via chemical reaction with the isocyanate group. Polypropylene glycol (PPG) had the highest physical removal efficiency and the lowest reaction rate with isocyanates. All tested skin decontaminants performed similarly, accomplishing decontamination primarily via physical processes and removing 70-80% of isocyanates in one wiping. Limitations of these skin decontaminants are discussed and alternatives presented. In vitro testing using animal skins and in vivo testing with field workers are being conducted to further assess the efficiency and identify related determinants.
Shinu, Pottathil; Singh, Varsha; Nair, Anroop; Mehrishi, Priya; Mehta, Sonia; Joshi, Ekta
2013-10-01
The study was designed to compare the efficacy of cetylpyridinium chloride (CPC) and sodium chloride (NaCl) decontamination method with N-acetyl L-Cystine (NALC) and sodium hydroxide (NaOH) decontamination (the reference method) method for the recovery of Mycobacterium tuberculosis (MTB) from clinically suspected cases of pulmonary tuberculosis. To evaluate CPC-NaCl and NALC-NaOH decontamination methods, sputum specimens (n = 796) were studied (culturing on Löwenstein-Jensen medium), and the performances were compared. The CPC-NaCl decontamination method demonstrated a sensitivity, specificity, negative predictive value, and positive predictive value of 97.99%, 87.53%, 70.19%, and 99.32%, respectively, when compared to NALC-NaOH decontamination method. In summary, CPC-NaCl decontamination method effectively detected significantly higher number of MTB cases (n = 208) than NALC-NaOH decontamination method (n = 149) particularly in sputum with scanty bacilli and smear-negative cases, indicating the potential of CPC-NaCl decontamination method to preserve paucibacillary cases more efficient than NALC-NaOH decontamination method. © 2013.
Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Klima-Comba, Amy K.; Stevens, Vanessa L.; Cronin, Tracy D.
2004-01-01
The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus (“Bacillus subtilis subsp. niger,” also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 105 to 106 CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies. PMID:15294810
Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Klima-Comba, Amy K; Stevens, Vanessa L; Cronin, Tracy D
2004-08-01
The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus ("Bacillus subtilis subsp. niger," also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 10(5) to 10(6) CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies.
Sudbrock, F; Schomäcker, K; Drzezga, A
2017-01-01
For planned and ongoing storage of liquid radioactive waste in a designated plant for a nuclear medicine therapy ward (decontamination system/decay system), detailed knowledge of basic parameters such as the amount of radioactivity and the necessary decay time in the plant is required. The design of the plant at the Department of Nuclear Medicine of the University of Cologne, built in 2001, was based on assumptions about the individual discharge of activity from patients, which we can now retrospectively validate. The decontamination factor of the plant is at present in the order of 10 -9 for 131 I. The annual discharges have been continuously reduced over the period of operation and are now in the region of a few kilobecquerels. This work emphasizes the high efficacy of the decontamination plant to reduce the amount of radioactivity released from the nuclear medicine ward into the environment to almost negligible levels. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kumar, M; Hora, R; Kostrzynska, M; Waites, W M; Warriner, K
2006-07-01
The efficacy of a stabilized oxychloro-based food grade sanitizer to decontaminate seeds destined for sprout production has been evaluated. By using mung bean seeds as a model system, it was demonstrated that the sanitizer could be used to inactivate a five-strain cocktail of Escherichia coli O157:H7 or Salmonella introduced onto beans at 10(3) to 10(4) CFU/g. Salmonella was more tolerant to stabilized oxychloro than was E. coli O157:H7, with sanitizer levels of >150 and >50 ppm, respectively, being required to ensure pathogen-free sprouts. The decontamination efficacy was also found to be dependent on treatment time (>8 h optimal) and the seed-to-sanitizer ratio (>1:4 optimal). Stabilized oxychloro treatment did not exhibit phytotoxic effects, as germination and sprout yields were not significantly (P > 0.05) different as compared with untreated controls. Although human pathogens could be effectively eliminated from mung beans, the aerobic plate count of native microflora on sprouts grown from treated seed was not significantly (P > 0.05) different from the controls. The diversity of microbial populations (determined through 16S rRNA denaturing gradient gel electrophoresis analysis) associated with bean sprouts was not significantly affected by the sanitizer treatment. However, it was noted that Klebsiella and Herbasprillum (both common plant endophytes) were absent in sprouts derived from decontaminated seed but were present in control sprouts. When a further range of seed types was evaluated, it was found that alfalfa, cress, flax, and soybean could be decontaminated with the stabilized oxychloro sanitizer. However, the decontamination efficacy with other seed types was less consistent. It appears that the rate of seed germination and putative activity of sanitizer sequestering system(s), in addition to other factors, may limit the efficacy of the decontamination method.
Sakai, Masaru; Gomi, Takashi; Nunokawa, Masanori; Wakahara, Taeko; Onda, Yuichi
2014-04-01
We investigated the biological accumulation of radiocesium in tadpoles [Rana (Pelophylax) porosa porosa] in rice paddies with and without decontamination practice at Fukushima. Radiocesium was accumulated in surface part of soils both in the control and decontaminated paddies one year after decontamination. Mean (134)Cs and (137)Cs concentrations in tadpoles in the control and decontaminated paddies were 3000 and 4500, and 600 and 890 Bq/kg dry weight, respectively. Radiocesium concentrations in surface soil (0-5 cm depth) and tadpoles in the decontaminated paddy were five times smaller than in the control paddy. These results suggest that decontamination practice can reduce radiocesium concentrations in both soil and tadpoles. However, at the decontaminated paddy, radiocesium concentrations in surface soils became 3.8 times greater one year after decontamination, which indicates that monitoring the subsequent movement of radiocesium in rice paddies and surrounding areas is essential for examining contamination propagation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Percutaneous toxicity and decontamination of soman, VX, and paraoxon in rats using detergents.
Misík, Jan; Pavliková, Růžena; Kuča, Kamil
2013-06-01
Highly toxic organophosphorus compounds (OPs) were originally developed for warfare or as agricultural pesticides. Today, OPs represent a serious threat to military personnel and civilians. This study investigates the in vivo decontamination of male Wistar rats percutaneously exposed to paraoxon and two potent nerve agents--soman (GD) and VX. Four commercial detergents were tested as decontaminants--Neodekont(TM), Argos(TM), Dermogel(TM), and FloraFree(TM). Decontamination performed 2 min after exposure resulted in a higher survival rate in comparison with non-decontaminated controls. The decontamination effectiveness was expressed as protective ratio (PR, median lethal dose of agent in decontaminated animals divided by the median lethal dose of agent in untreated animals). The highest decontamination effectiveness was consistently achieved with Argos(TM) (PR=2.3 to 64.8), followed by Dermogel(TM) (PR=2.4 to 46.1). Neodekont(TM) and FloraFree(TM) provided the lowest decontamination effectiveness, equivalent to distilled water (PR=1.0 to 43.2).
Bilibana, Mawethu Pascoe; Yeoh, Tzi Shien; Tang, Thean-Hock
2017-01-01
The binding specificity and affinity of aptamers have long been harnessed as the key elements in the development of aptamer-based assays, particularly aptasensing application. One promising avenue that is currently explored based on the specificity and affinity of aptamers is the application of aptamers in the decontamination assays. Aptamers have been successfully harnessed as the decontamination agents to remove contaminants from the environment and to decontaminate infectious elements. The reversible denaturation property inherent in aptamers enables the repeated usage of aptamers, which can immensely save the cost of decontamination. Analogous to the point-of-care diagnostics, there is no doubt that aptamers can also be deployed in the point-of-care aptamer-based decontamination assay, whereby decontamination can be performed anywhere and anytime for instantaneous decision-making. It is also prophesied that aptamers can also serve more than as a decontaminant, probably as a tool to capture and kill hazardous elements, particularly pathogenic agents. PMID:29225967
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cristy, G.A.; Jernigan, H.C.
1981-02-01
The record of the proceedings of the workshop on environmental decontamination contains twenty-seven presentations. Emphasis is placed upon soil and surface decontamination, the decommissioning of nuclear facilities, and assessments of instrumentation and equipment used in decontamination. (DLS)
Supporting Calculations For Submerged Bed Scrubber Condensate Disposal Preconceptual Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pajunen, A. J.; Tedeschi, A. R.
This document provides supporting calculations for the preparation of the Submerged Bed Scrubber Condensate Disposal Preconceptual Study report The supporting calculations include equipment sizing, Hazard Category determination, and LAW Melter Decontamination Factor Adjustments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hovanec, J.W.; Szafraniec, L.L.; Albizo, J.M.
1993-04-01
Standard decontaminant formulations, aqueous sodium hydroxide and aqueous sodium hypochlorite, were providing slow and incomplete results when used to decontaminate certain operating facilities at the Johnston Atoll Chemical Agent Disposal System and the Chemical Agent Disposal System (Utah). A study was undertaken to define the capabilities and limitations of using concentrated sodium hydroxide to decontaminate VX, the effect of adding hydrogen peroxide to the sodium hydroxide for the decontamination of VX, the efficacy of aqueous oxone for the decontamination of VX, and the efficacy of oxone in a water/1-methyl-2-pyrrolidinone (MP) mixture for the decontamination of HD. Using aqueous sodium hydroxidemore » alone was not desirable since the formation of toxic EA2192 could not be averted. However, the addition of hydrogen peroxide resulted in effective VX decontamination without EA2192 formation. Aqueous oxone was also found to be effective for both VX and HD. The incorporation of MP did little to improve HD dissolution and reacted with the oxone to reduce the effective usable life of the decontamination solution. Thus, the use of MP in HD decontamination was not recommended.« less
Decontamination Efficacy and Skin Toxicity of Two Decontaminants against Bacillus anthracis
Stratilo, Chad W.; Crichton, Melissa K. F.; Sawyer, Thomas W.
2015-01-01
Decontamination of bacterial endospores such as Bacillus anthracis has traditionally required the use of harsh or caustic chemicals. The aim of this study was to evaluate the efficacy of a chlorine dioxide decontaminant in killing Bacillus anthracis spores in solution and on a human skin simulant (porcine cadaver skin), compared to that of commonly used sodium hypochlorite or soapy water decontamination procedures. In addition, the relative toxicities of these decontaminants were compared in human skin keratinocyte primary cultures. The chlorine dioxide decontaminant was similarly effective to sodium hypochlorite in reducing spore numbers of Bacillus anthracis Ames in liquid suspension after a 10 minute exposure. After five minutes, the chlorine dioxide product was significantly more efficacious. Decontamination of isolated swine skin contaminated with Bacillus anthracis Sterne with the chlorine dioxide product resulted in no viable spores sampled. The toxicity of the chlorine dioxide decontaminant was up to two orders of magnitude less than that of sodium hypochlorite in human skin keratinocyte cultures. In summary, the chlorine dioxide based decontaminant efficiently killed Bacillus anthracis spores in liquid suspension, as well as on isolated swine skin, and was less toxic than sodium hypochlorite in cultures of human skin keratinocytes. PMID:26394165
Amlôt, Richard; Carter, Holly; Riddle, Lorna; Larner, Joanne; Chilcott, Robert P
2017-01-01
Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an "Initial Operational Response" by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer's forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised dry decontamination may not be performed correctly or safely.
Riddle, Lorna; Larner, Joanne
2017-01-01
Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an “Initial Operational Response” by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer’s forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised dry decontamination may not be performed correctly or safely. PMID:28622352
Joosen, M J A; van den Berg, R M; de Jong, A L; van der Schans, M J; Noort, D; Langenberg, J P
2017-04-01
The main goal of the present study was to obtain insight into depot formation and penetration following percutaneous VX poisoning, in order to identify an appropriate decontamination window that can enhance or support medical countermeasures. The study was executed in two phases, using the hairless guinea pig as an animal model. In the first phase the effect of various decontamination regimens on levels of free VX in skin and plasma were studied as well as on blood cholinesterase levels. Animals were exposed to 0.5 mg/kg VX and were not decontaminated (control), decontaminated with RSDL once at 15 or 90 min after exposure or three times at 15, 25 and 35 (10-min interval) or 15, 45 and 75 min after exposure (30-min interval). There was no significant effect of any of the decontamination regimens on the 6-h survival rate of the animals. However, all animals that had been decontaminated 15 min after exposure, showed a survival rate of more than 90%, compared to 50-60% in animals that were not decontaminated or decontaminated at 90 min after exposure. In the second phase of the study, hairless guinea pigs were exposed to 1 mg/kg VX on the shoulder, followed either by decontamination with RSDL (10 min interval), conventional treatment on indication of clinical signs or a combination thereof. It appeared that a thorough, repeated decontamination alone could not save the majority of the animals. A 100% survival rate was observed in the group that received a combination of decontamination and treatment. In conclusion, the effects of VX exposure could be influenced by various RSDL decontamination regimens. The results in freely moving animals showed that skin decontamination, although not fully effective in removing all VX from the skin and skin depot is crucial to support pharmacological intervention. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Evaluation of time required for water-only decontamination of an oil-based agent.
Moffett, Peter M; Baker, Benjamin L; Kang, Christopher S; Johnson, Melinda S
2010-03-01
The objective was to evaluate the time to decontaminate an area of skin exposed to an oil-based agent using a water-only decontamination protocol. A fluorescent mock chemical/biological agent was created. Each of 20 subjects had his/her forearm sprayed with the agent. Each subject placed his/her arm under a decontamination shower, which provided water at a pressure of 60-70 psi and 35 degrees C. After 30 sec a black light was used by three evaluators to determine whether the agent was removed. The process of 30 sec decontamination and re-evaluation was repeated for a total of 5 min. The primary endpoint was proportion decontaminated over time. After 90 sec, 100% of subjects were decontaminated. Whereas the data suggest the possibility of rapid water-only decontamination, the applicability of this data in current form is doubtful, but provides a model as a basis for future study.
Harrison, Tyler R; Muhamad, Jessica Wendorf; Yang, Fan; Morgan, Susan E; Talavera, Ed; Caban-Martinez, Alberto; Kobetz, Erin
2018-04-01
Firefighters are exposed to carcinogens such as volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) during fires and from their personal protective equipment (PPE). Recent research has shown that decontamination processes can reduce contamination on both gear and skin. While firefighter cultures that honor dirty gear are changing, little is known about current attitudes and behaviors toward decontamination in the fire service. Four hundred eighty-five firefighters from four departments completed surveys about their attitudes, beliefs, perceived norms, barriers, and behaviors toward post-fire decontamination processes. Overall, firefighters reported positive attitudes, beliefs, and perceived norms about decontamination, but showering after a fire was the only decontamination process that occurred regularly, with field decontamination, use of cleansing wipes, routine gear cleaning, and other behaviors all occurring less frequently. Firefighters reported time and concerns over wet gear as barriers to decontamination.
A biological decontamination process for small, privately owned buildings.
Krauter, Paula; Tucker, Mark
2011-09-01
An urban wide-area recovery and restoration effort following a large-scale biological release will require extensive resources and tax the capabilities of government authorities. Further, the number of private decontamination contractors available may not be sufficient to respond to the needs. These resource limitations could create the need for decontamination by the building owner/occupant. This article provides owners/occupants with a simple method to decontaminate a building or area following a wide-area release of Bacillus anthracis using liquid sporicidal decontamination materials, such as pH-amended bleach or activated peroxide; simple application devices; and high-efficiency particulate air-filtered vacuums. Owner/occupant decontamination would be recommended only after those charged with overseeing decontamination-the Unified Command/Incident Command-identify buildings and areas appropriate for owner/occupant decontamination based on modeling and environmental sampling and conduct health and safety training for cleanup workers.
2011-09-01
low‐cost, lightweight, single‐use individual product for field self ‐decontamination. Surface (skin) decontamination of Bacillus subtilis spores has...field spray decontamination unit was previously demonstrated in 2003 at Guantanamo Bay, Cuba (Dankert, 2003), and for wound healing with repeated...Technology on plastics, rubber and plastic tubing, and clothing. Demonstrate ability of CleanseFx to function as skin cleanser in military setting
Reactive decontamination formulation
Giletto, Anthony [College Station, TX; White, William [College Station, TX; Cisar, Alan J [Cypress, TX; Hitchens, G Duncan [Bryan, TX; Fyffe, James [Bryan, TX
2003-05-27
The present invention provides a universal decontamination formulation and method for detoxifying chemical warfare agents (CWA's) and biological warfare agents (BWA's) without producing any toxic by-products, as well as, decontaminating surfaces that have come into contact with these agents. The formulation includes a sorbent material or gel, a peroxide source, a peroxide activator, and a compound containing a mixture of KHSO.sub.5, KHSO.sub.4 and K.sub.2 SO.sub.4. The formulation is self-decontaminating and once dried can easily be wiped from the surface being decontaminated. A method for decontaminating a surface exposed to chemical or biological agents is also disclosed.
Dalton, Christopher H; Hall, Charlotte A; Lydon, Helen L; Chipman, J K; Graham, John S; Jenner, John; Chilcott, Robert P
2015-05-01
The risk of penetrating, traumatic injury occurring in a chemically contaminated environment cannot be discounted. Should a traumatic injury be contaminated with a chemical warfare (CW) agent, it is likely that standard haemostatic treatment options would be complicated by the need to decontaminate the wound milieu. Thus, there is a need to develop haemostatic products that can simultaneously arrest haemorrhage and decontaminate CW agents. The purpose of this study was to evaluate a number of candidate haemostats for efficacy as skin decontaminants against three CW agents (soman, VX and sulphur mustard) using an in vitro diffusion cell containing undamaged pig skin. One haemostatic product (WoundStat™) was shown to be as effective as the standard military decontaminants Fuller's earth and M291 for the decontamination of all three CW agents. The most effective haemostatic agents were powder-based and use fluid absorption as a mechanism of action to sequester CW agent (akin to the decontaminant Fuller's earth). The envisaged use of haemostatic decontaminants would be to decontaminate from within wounds and from damaged skin. Therefore, WoundStat™ should be subject to further evaluation using an in vitro model of damaged skin. Copyright © 2014 Crown copyright. Journal of Applied Toxicology © 2014 John Wiley & Sons, Ltd.
Purge- and intensive-purge decontamination of dental units contaminated with biofilm
Kramer, Axel; Assadian, Ojan; Bachfeld, Danny; Meyer, Georg
2012-01-01
Introduction: During hygienic-microbiological monitoring of the water quality in dental units, the total bacterial colony count was found to exceed the limits for drinking water quality; in addition, mold contamination was detected. The presumed cause was irregular decontamination of the units through purging and intensive decontamination. Methods: To decontaminate the units, the manufacturer’s recommended program for cleaning and intensive decontamination was intensified by shortened intervals over a 2-week period. For Sirona units, instead of once a day, the automatic purge program was run every morning and evening for 20 min each time, and instead of once a month, intensive decontamination was performed every two weeks; this schedule has been maintained since then. For KaVo units, cleaning with the hydroclean function was carried out for 2.5 min every morning and evening. The automatic intensive decontamination was run daily instead of weekly. A maintenance log book was introduced, in which decontamination/cleaning was confirmed by the operator’s signature. Results: Within 5 weeks, all previously contaminated units were decontaminated. Discussion: By shortening the cleaning and intensive decontamination intervals in a 2-week period with subsequent control that the recommended maintenance intervals were kept, it was possible to guarantee drinking-water quality in the dental units of both manufacturers. PMID:22558045
Assessing cost and effectiveness of radiation decontamination in Fukushima Prefecture, Japan.
Yasutaka, Tetsuo; Naito, Wataru
2016-01-01
Despite the enormous cost of radiation decontamination in Fukushima Prefecture, it is not clear what levels of reduction in external radiation exposure are possible in the Special Decontamination Area, the Intensive Contamination Survey Areas and the whole of Fukushima. The objective of this study was to evaluate the cost and effectiveness of radiation decontamination in Fukushima Prefecture in its entirety. Using a geographic information system, we calculated the costs of removal, storage containers, transport, and temporary and interim storage facilities as well as the reduction in air dose rate for a cumulative external exposure for 9000 1 km × 1 km mesh units incorporating 51 municipalities. The decontamination cost for the basic scenario, for which forested areas within 20 m of habitation areas were decontaminated, was JPY2.53-5.12 trillion; the resulting reduction in annual external dose was about 2500 person-Sv. The transport, storage, and administrative costs of decontamination waste and removed soil reached JPY1.55-2.12 trillion under this scenario. Although implementing decontamination of all forested areas provides some major reductions in the external radiation dose for the average inhabitant, decontamination costs could potentially exceed JPY16 trillion. These results indicate that technologies for reducing the volume of decontamination waste and removed soil should be considered to reduce storage costs and that further discussions about forest decontamination policies are needed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Decontamination of chemical tracers in droplets by a submerging thin film flow
NASA Astrophysics Data System (ADS)
Landel, Julien R.; McEvoy, Harry; Dalziel, Stuart B.
2016-11-01
We investigate the decontamination of chemical tracers contained in small viscous drops by a submerging falling film. This problem has applications in the decontamination of hazardous chemicals, following accidental releases or terrorist attacks. Toxic droplets lying on surfaces are cleaned by spraying a liquid decontaminant over the surface. The decontaminant film submerges the droplets, without detaching them, in order to neutralize toxic chemicals in the droplets. The decontamination process is controlled by advection, diffusion and reaction processes near the drop-film interface. Chemical tracers dissolve into the film flow forming a thin diffusive boundary layer at the interface. The chemical tracers are then neutralized through a reaction with a chemical decontaminant transported in the film. We assume in this work that the decontamination process occurs mainly in the film phase owing to low solubility of the decontaminant in the drop phase. We analyze the impact of the reaction time scale, assuming first-order reaction, in relation with the characteristic advection and diffusion time scales in the case of a single droplet. Using theoretical, numerical and experimental means, we find that the reaction time scale need to be significantly smaller than the characteristic time scale in the diffusive boundary layer in order to enhance noticeably the decontamination of a single toxic droplet. We discuss these results in the more general case of the decontamination of a large number of droplets. This material is based upon work supported by the Defense Threat Reduction Agency under Contract No. HDTRA1-12-D-0003-0001.
40 CFR 170.150 - Decontamination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Decontamination. 170.150 Section 170... PROTECTION STANDARD Standard for Workers § 170.150 Decontamination. (a)(1) Requirement. The agricultural employer must provide decontamination supplies for workers in accordance with this section whenever: (i...
Nastou, Aikaterini; Rhoades, Jonathan; Smirniotis, Petros; Makri, Ioanna; Kontominas, Michael; Likotrafiti, Eleni
2012-10-15
The efficacy of household decontamination methods at reducing Listeria monocytogenes on fresh lettuce (Lactuca sativa), cucumber (Cucumis sativus) and parsley (Petroselinum sativum) was studied. Inoculated vegetable pieces were immersed in washing solutions and surviving L. monocytogenes enumerated. Parameters investigated were storage temperature prior to washing, dipping water temperature, agitation, acetic acid concentration and immersion time. The results indicated that the storage temperature significantly affects the efficacy of dipping vegetables in water for the control of L. monocytogenes, as the reduction in count was greatest when products had been stored at cooler temperatures. Decontamination with acetic acid (up to 2.0% v/v) was shown to have some effect in most cases, but the highest observed decrease in count was 2.6 log cfu/g. Experiments investigating the effect of exposure time to acetic acid (0.5% and 1.0% v/v, up to 30 min immersion) indicated that immersing the vegetables for more than 10 min is of minimal benefit. The most significant factor affecting washing and decontamination efficacy was the vegetable itself: L. monocytogenes colonizing cucumber epidermis was far more resistant to removal by washing and to acid treatment than that on the leafy vegetables, and L. monocytogenes on parsley was the most susceptible. This shows that published decontamination experiments (often performed with lettuce) cannot necessarily be extrapolated to other vegetables. Copyright © 2012 Elsevier B.V. All rights reserved.
Decontamination of Subway Railcar and Related Materials ...
Report In the event of a biological incident in a transportation hub such as a subway system, effective remediation of railcars, subway tunnels and stations will require the use of various decontamination approaches. One potential decontamination tool that could be used in such an event is the fogging of sporicidal liquids. The study described in this report builds on previous fogging decontamination research, but with a focus on decontaminating subway railcars and related materials.
Horby, P.; Murray, V.; Cummins, A.; Mackway-Jones, K.; Euripidou, R.
2000-01-01
Objectives—To evaluate the capability of accident and emergency (A&E) departments in six health regions of England to safely decontaminate casualties exposed to hazardous chemicals. Methods—In January 1999 a postal questionnaire was sent to the clinical director of all A&E departments in Trent, North and South Thames, South and West, North West and, Anglia and Oxford Health Regions. The questionnaire inquired about characteristics of the department, decontamination facilities and equipment, and staff training. Non-responders were sent a second questionnaire and contacted by telephone if they failed to respond to the second mailing. Results—308 of 326 departments identified (94%) returned a questionnaire. There was no significant difference in response rate by region (p = 0.99). Analysis was restricted to 154 major departments seeing more than 20 000 new attendances per year. Of these 154 departments, 109 (71%) had a written chemical incident plan but only 55 (36%) maintained a list of nearby industrial chemical sites. Fifty nine departments (38%) stated that members of staff had received training in the management of chemically contaminated casualties in the preceding year. Eighteen departments (12%) possessed the level of personal protective equipment (PPE) recommended for decontamination by the Ambulance Services Association. Ninety six departments (62%) had a designated decontamination room but only seven (7%) of them incorporated all the features generally considered necessary for safe decontamination. Forty one units (27%) had the capability to decontaminate casualties outside of the department either with warm water from a shower attachment or with a mobile decontamination unit. Thirty six departments (23%) had neither a decontamination room nor the ability to decontaminate casualties outside the department. Only 16 units (10%) had both adequate PPE and either a decontamination room or the capability to decontaminate outside the department. Conclusions—This study has identified deficiencies in the current NHS capability to respond to chemical incidents. To resolve this, nationally recognised standards for decontamination facilities, equipment and training should be formulated, agreed and implemented. PMID:11005405
NASA Astrophysics Data System (ADS)
Giusti, J. S. M.; Santos-Pinto, L.; Pizzolitto, A. C.; Kurachi, C.; Bagnato, V. S.
2006-05-01
The aim of this study was the evaluation of the effectiveness of photodynamic therapy on the decontamination of artificially induced carious bovine dentin, using Photogem® as the photosensitizer agent and an LED device as a light source. Dentin samples obtained from bovine incisors were immersed in sterile broth supplemented by Lactobacillus acidophillus 108 colony formation units (CFU) and Streptococcus mutans 108 CFU. Different concentrations of photosensitizer, PA = 1 mg/ml, PB = 2 mg/ml, and PC = 3 mg/ml, and two fluences, D = 24 J/cm2 and D = 48 J/cm2, were investigated. After CFU counting per milligram of carious dentin and statistical analysis, we observed that the photodynamic therapy (PDT) parameters used were effective for bacterial reduction in the in vitro model under study. The best result was achieved with the application of Photogem® at 2 mg/ml and photoactivated under 24 J/cm2 showing a survival factor of 0.14. At higher photosensitizer concentrations, a higher dark toxicity was observed. We propose a simple mathematical expression for the determination of PDT parameters of photosensitizer concentration and light fluence for different survival factor values. Since LED devices are simpler and cheaper compared to laser systems, it would be interesting to verify their efficacy as a light source in photodynamic therapy for the decontamination of carious dentin.
Wang, Yaxing; Lu, Huangjie; Dai, Xing; Duan, Tao; Bai, Xiaojing; Cai, Yawen; Yin, Xuemiao; Chen, Lanhua; Diwu, Juan; Du, Shiyu; Zhou, Ruhong; Chai, Zhifang; Albrecht-Schmitt, Thomas E; Liu, Ning; Wang, Shuao
2018-02-19
The coexistence of radioactive contaminants (e.g., thorium, uranium, and their daughters) in rare earth minerals introduces significant environmental, economic, and technological hurdles in modern rare earth production. Efficient, low cost, and green decontamination strategies are therefore desired to ameliorate this problem. We report here a single-step and quantitative decontamination strategy of thorium from rare earths based on a unique periodic trend in the formation of crystalline selenite compounds across the lanthanide series, where Ce(III) is fully oxidized in situ to Ce(IV). This gives rise to a crystallization system that is highly selective to trap tetravalent f-blocks while all other trivalent lanthanides completely remain in solution when coexist. These results are bolstered by first-principles calculations of lattice energies and an examination of bonding in these compounds. This system is contrasted with typical natural and synthetic systems, where trivalent and tetravalent f-block elements often cocrystallize. The separation factors after one round of crystallization were determined from binary systems of Th(IV)/La(III), Th(IV)/Eu(III), and Th(IV)/Yb(III) to reach 2.1 × 10 5 , 1.2 × 10 5 , and 9 × 10 4 , respectively. Selective crystallization of thorium from a simulated monazite composite yields a separation factor of 1.9 × 10 3 with nearly quantitative removal of thorium.
Krauter, Paula; Edwards, Donna; Yang, Lynn; Tucker, Mark
2011-09-01
Decontamination and recovery of a facility or outdoor area after a wide-area biological incident involving a highly persistent agent (eg, Bacillus anthracis spores) is a complex process that requires extensive information and significant resources, which are likely to be limited, particularly if multiple facilities or areas are affected. This article proposes a systematic methodology for evaluating information to select the decontamination or alternative treatments that optimize use of resources if decontamination is required for the facility or area. The methodology covers a wide range of approaches, including volumetric and surface decontamination, monitored natural attenuation, and seal and abandon strategies. A proposed trade-off analysis can help decision makers understand the relative appropriateness, efficacy, and labor, skill, and cost requirements of the various decontamination methods for the particular facility or area needing treatment--whether alone or as part of a larger decontamination effort. Because the state of decontamination knowledge and technology continues to evolve rapidly, the methodology presented here is designed to accommodate new strategies and materials and changing information.
Carter, Holly; Amlôt, Richard
2016-01-01
Introduction: Mass casualty decontamination is an intervention employed by first responders at the scene of an incident involving noxious contaminants. Many countries have sought to address the challenge of decontaminating large numbers of affected casualties through the provision of rapidly deployable temporary showering structures, with accompanying decontamination protocols. In this paper we review decontamination guidance for emergency responders and associated research evidence, in order to establish to what extent psychosocial aspects of casualty management have been considered within these documents. The review focuses on five psychosocial aspects of incident management: likely public behaviour; responder management style; communication strategy; privacy/ modesty concerns; and vulnerable groups. Methods: Two structured literature reviews were carried out; one to identify decontamination guidance documents for first responders, and another to identify evidence which is relevant to the understanding of the psychosocial aspects of mass decontamination. The guidance documents and relevant research were reviewed to identify whether the guidance documents contain information relating to psychosocial issues and where it exists, that the guidance is consistent with the existing evidence-base. Results: Psychosocial aspects of incident management receive limited attention in current decontamination guidance. In addition, our review has identified a number of gaps and inconsistencies between guidance and research evidence. For each of the five areas we identify: what is currently presented in guidance documents, to what extent this is consistent with the existing research evidence and where it diverges. We present a series of evidence-based recommendations for updating decontamination guidance to address the psychosocial aspects of mass decontamination. Conclusions: Effective communication and respect for casualties’ needs are critical in ensuring decontamination is completed quickly and effectively. We identify a number of areas requiring further research including: identifying effective methods for communicating in an emergency; better understanding of the needs of vulnerable groups during decontamination; effective training for emergency responders on psychosocial issues, and pre-incident public education for incidents involving emergency decontamination. It is essential that the psychosocial aspects of mass decontamination are not neglected in the pursuit of solely technical solutions. PMID:27790383
RSDL decontamination of human skin contaminated with the nerve agent VX.
Thors, L; Lindberg, S; Johansson, S; Koch, B; Koch, M; Hägglund, L; Bucht, A
2017-03-05
Dermal exposure to low volatile organophosphorus compounds (OPC) may lead to penetration through the skin and uptake in the blood circulation. Skin decontamination of toxic OPCs, such as pesticides and chemical warfare nerve agents, might therefore be crucial for mitigating the systemic toxicity following dermal exposure. Reactive skin decontamination lotion (RSDL) has been shown to reduce toxic effects in animals dermally exposed to the nerve agent VX. In the present study, an in vitro flow-through diffusion cell was utilized to evaluate the efficacy of RSDL for decontamination of VX exposed to human epidermis. In particular, the impact of timing in the initiation of decontamination and agent dilution in water was studied. The impact of the lipophilic properties of VX in the RSDL decontamination was additionally addressed by comparing chemical degradation in RSDL and decontamination efficacy between the VX and the hydrophilic OPC triethyl phosphonoacetate (TEPA). The epidermal membrane was exposed to 20, 75 or 90% OPC diluted in deionized water and the decontamination was initiated 5, 10, 30, 60 or 120min post-exposure. Early decontamination of VX with RSDL, initiated 5-10min after skin exposure, was very effective. Delayed decontamination initiated 30-60min post-exposure was less effective but still the amount of penetrated agent was significantly reduced, while further delayed start of decontamination to 120min resulted in very low efficacy. Comparing RSDL decontamination of VX with that of TEPA showed that the decontamination efficacy at high agent concentrations was higher for VX. The degradation mechanism of VX and TEPA during decontamination was dissected by 31 P NMR spectroscopy of the OPCs following reactions with RSDL and its three nucleophile components. The degradation rate was clearly associated with the high pH of the specific solution investigated; i.e. increased pH resulted in a more rapid degradation. In addition, the solubility of the OPC in RSDL also influenced the degradation rate since the degradation of VX was significantly faster when the NMR analysis was performed in the organic solvent acetonitrile compared to water. In conclusion, we have applied the in vitro flow-through diffusion cell for evaluation of skin decontamination procedures of human epidermis exposed to OPCs. It was demonstrated that early decontamination is crucial for efficient mitigation of epidermal penetration of VX and that almost complete removal of the nerve agent from the skin surface is possible. Our data also indicate that the pH of RSDL together with the solubility of OPC in RSDL are of primary importance for the decontamination efficacy. Copyright © 2017 Elsevier B.V. All rights reserved.
Gross decontamination experiment report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, R.; Kinney, K.; Dettorre, J.
1983-07-01
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established formore » the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.« less
46 CFR 154.1410 - Decontamination shower.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Decontamination shower. 154.1410 Section 154.1410... Equipment § 154.1410 Decontamination shower. When Table 4 references this section, a vessel carrying the listed cargo must have a decontamination shower and an eye wash that: (a) Are on the weatherdeck; and (b...
46 CFR 154.1410 - Decontamination shower.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Decontamination shower. 154.1410 Section 154.1410... Equipment § 154.1410 Decontamination shower. When Table 4 references this section, a vessel carrying the listed cargo must have a decontamination shower and an eye wash that: (a) Are on the weatherdeck; and (b...
Developments in Decontamination Technologies of Military Personnel and Equipment
NASA Astrophysics Data System (ADS)
Sata, Utkarsh R.; Ramkumar, Seshadri S.
Individual protection is important for warfighters, first responders and civilians to meet the current threat of toxic chemicals and chemical warfare (CW) agents. Within the realm of individual protection, decontamination of warfare agents is not only required on the battlefield but also in laboratory, pilot plants, production and agent destruction sites. It is of high importance to evaluate various decontaminants and decontamination techniques for implementing the best practices in varying scenarios such as decontamination of personnel, sites and sensitive equipment.
Mercury bioaccumulation and decontamination kinetics in the edible cockle Cerastoderma edule.
Cardoso, P G; Grilo, T F; Pereira, E; Duarte, A C; Pardal, M A
2013-02-01
Mercury bioaccumulation and decontamination kinetics in the edible cockle Cerastoderma edule were studied through a mesocosms experiment after a medium-term exposure to the metal. The results revealed that the bivalve presented distinct bioaccumulation kinetics according to the different tissues. While the gills showed a linear accumulation pattern, the digestive gland and the entire organism presented a saturation model, with higher accumulation during the first 7d of exposure and lower during the rest of the time. In addition, the bioaccumulation rate was not proportional to the Hg concentration, since the organisms under lower contamination presented higher bioconcentration factors than the ones under higher contamination. Gills were the tissues with higher mercury accumulation capability. Concerning the decontamination phase, C. edule lost approximately 80% of the mercury after 24h exposure in clean seawater. Nevertheless, never reached the original condition, showing in the final (20 d detox), Hg levels (>0.5 ppm) higher than those allowed by the legislation regulating human food consumption. This represents a matter of concern for Human health. Copyright © 2012 Elsevier Ltd. All rights reserved.
Results of chemical decontamination of DOE`s uranium-enrichment scrap metal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levesque, R.G.
1997-02-01
The CORPEX{reg_sign} Nuclear Decontamination Processes were used to decontaminate representative scrap metal specimens obtained from the existing scrap metal piles located at the Department of Energy (DOE) Portsmouth Gaseous Diffusion Plant (PORTS), Piketon, Ohio. In September 1995, under contract to Lockheed Martin Energy Systems, MELE Associates, Inc. performed the on-site decontamination demonstration. The decontamination demonstration proved that significant amounts of the existing DOE scrap metal can be decontaminated to levels where the scrap metal could be economically released by DOE for beneficial reuse. This simple and environmentally friendly process can be used as an alternative, or in addition to, smeltingmore » radiologically contaminated scrap metal.« less
Wada, Koji; Yoshikawa, Toru; Murata, Masaru
2012-01-01
This article describes occupational health measures for workers involved in decontamination of radioactive material discharged around Fukushima Dai-ichi Nuclear Power Plant after the explosions in 2011. Decontamination is performed by removing radioactive particles (mainly cesium) from surfaces of soil, grass and trees, and buildings. Measurement of radiation doses is necessary to reduce exposure, and to determine whether workers can work below dose limits. Protective equipment for decontamination is determined based on the concentration of radiation in contaminated soil and the exposure to dust. Health examinations by physicians are mandated for decontamination workers upon hiring and every 6 months. While there is no possibility of acute radiation injury from decontamination, workers may be anxious about the unclear effects of chronic low level radiation exposure on health. Measures to protect the decontamination workers are the top priority.
Schwartz, M D; Hurst, C G; Kirk, M A; Reedy, S J D; Braue, E H
2012-08-01
Rapid decontamination of the skin is the single most important action to prevent dermal absorption of chemical contaminants in persons exposed to chemical warfare agents (CWA) and toxic industrial chemicals (TICs) as a result of accidental or intentional release. Chemicals on the skin may be removed by mechanical means through the use of dry sorbents or water. Recent interest in decontamination systems which both partition contaminants away from the skin and actively neutralize the chemical has led to the development of several reactive decontamination solutions. This article will review the recently FDA-approved Reactive Skin Decontamination Lotion (RSDL) and will summarize the toxicity and efficacy studies conducted to date. Evidence of RSDL's superior performance against vesicant and organophosphorus chemical warfare agents compared to water, bleach, and dry sorbents, suggests that RSDL may have a role in mass human exposure chemical decontamination in both the military and civilian arenas.
A rapid and inexpensive bioassay to evaluate the decontamination of organophosphates.
Claborn, David M; Martin-Brown, Skylar A; Sagar, Sanjay Gupta; Durham, Paul
2012-01-01
An inexpensive and rapid bioassay using adult red flour beetles was developed for use in assessing the decontamination of environments containing organophosphates and related chemicals. A decontamination protocol was developed which demonstrated that 2 to 3 applications of 5% bleach solution were required to obtain nearly complete decontamination of malathion. The bioassay was also used to screen common household cleaners as potential decontaminating agents, but only 5% bleach was effective at improving survival of insects on steel plates treated with 25% malathion. A toxic degradation product (malaoxon) was detected using gas chromatography/mass spectrophotometry; this toxin affected the decontamination efficacy and resulted in continued toxicity to the beetles until subsequent decontaminations. The bioassay provides evidence to support the use of red flour beetles as a sensitive, less expensive method for determining safety levels of environments contaminated with malathion and other toxins, and may have application in the study of chemical warfare agents.
Silver, G.L.
1980-09-24
The present invention provides a process for decontaminating a radioactive liquid containing a radioactive element capable of forming a hydroxide. This process includes the steps of contacting the radioactive liquid with a decontaminating composition and separating the resulting radioactive sludge from the resulting liquid. The decontaminating composition contains calcium cyanamide.
Hopkins, F B; Gravett, M R; Self, A J; Wang, M; Chua, Hoe-Chee; Hoe-Chee, C; Lee, H S Nancy; Sim, N Lee Hoi; Jones, J T A; Timperley, C M; Riches, J R
2014-08-01
Detailed chemical analysis of solutions used to decontaminate chemical warfare agents can be used to support verification and forensic attribution. Decontamination solutions are amongst the most difficult matrices for chemical analysis because of their corrosive and potentially emulsion-based nature. Consequently, there are relatively few publications that report their detailed chemical analysis. This paper describes the application of modern analytical techniques to the analysis of decontamination solutions following decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). We confirm the formation of N,N-diisopropylformamide and N,N-diisopropylamine following decontamination of VX with hypochlorite-based solution, whereas they were not detected in extracts of hydroxide-based decontamination solutions by nuclear magnetic resonance (NMR) spectroscopy or gas chromatography-mass spectrometry. We report the electron ionisation and chemical ionisation mass spectroscopic details, retention indices, and NMR spectra of N,N-diisopropylformamide and N,N-diisopropylamine, as well as analytical methods suitable for their analysis and identification in solvent extracts and decontamination residues.
Misik, Jan; Pavlikova, Ruzena; Josse, Denis; Cabal, Jiri; Kuca, Kamil
2012-09-01
Misuse of various chemicals, such as chemical warfare agents, industrial chemicals or pesticides during warfare or terrorists attacks requires adequate protection. Thus, development and evaluation of novel decontamination dispositives and techniques are needed. In this study, in vitro permeation and decontamination of a potentially hazardous compound paraoxon, an active metabolite of organophosphorus pesticide parathion, was investigated. Skin permeation and decontamination experiments were carried out in modified Franz diffusion cells. Pig skin was used as a human skin model. Commercially produced detergent-based washing solutions FloraFree(™) and ArgosTM were used as decontamination means. The experiments were done under "warm", "cold", "dry" and "wet" skin conditions in order to determine an effect of various physical conditions on skin permeation of paraoxon and on a subsequent decontamination process. There was no significant difference in skin permeation of paraoxon under warm, cold and dry conditions, whereas wet conditions provided significantly higher permeation rates. In the selected conditions, decontamination treatments performed 1 h after a skin exposure did not decrease the agent volume that permeated through the skin. An exception were wet skin conditions with non-significant decontamination efficacy 18 and 28% for the FloraFree(™) and Argos(™) treatment, respectively. In contrast, the skin permeation of paraoxon under warm, cold and dry conditions increased up to 60-290% following decontamination compared to non-decontaminated controls. This has previously been described as a skin wash-in effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pirro, J.
This report presents the results of a technical assessment of decontamination alternative prepared for the Western New York Nuclear Service Center (WNYNSC). The purpose of the assessment is to determine the recommended method for decontamination of cell surfaces and decontamination and removal of fuel reprocessing cell equipment to permit manual entry into the cells for the installation of waste solidification equipment. The primary cells of interest are the PMC, GPC, and CPC because they offer the largest usable volume for the solidification program. The secondary cells include XC-1, XC-2, XC-3 and the PPC which may be needed to support themore » solidification program. Five decontamination assessments were evaluated (A-E). The assessments included the estimated cost, occupational exposure, duration, manpower, waste volume generated, and final cell radiation levels achieved with the alternative decontamination methods. The methods varied from thorough destructive decontamination to equipment removal without decontamination followed by cell wall and floor decontamination. The recommended method for the primary cells is to utilize the remote manipulators and cranes to the maximum extent possible to decontaminate equipment and cell surfaces remotely, and to remove the equipment for temporary on-site storage. The recommended method for secondary cell decontamination is to remotely decontaminate the cells to the maximum extent possible prior to manned entry for contact-removal of the fuel reprocessing equipment (Assessment D). Assessment A is expected to cost $8,713,500 in 1980 dollars (including a 25% contingency) and will result in an occupational exposure of 180.3 manRem. Assessment D is expected to cost $11,039,800 and will result in an occupational exposure of 259 manRems.« less
Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G James; Williams, Richard
2014-01-01
The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) 'Theory-based communication': Health-focused explanations about decontamination, and sufficient practical information; 2) 'Standard practice communication': No health-focused explanations about decontamination, sufficient practical information; 3) 'Brief communication': No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with responders, which in turn resulted in higher levels of expected compliance during a real incident, and increased willingness to help other members of the public. This study shows that an understanding of the social identity approach facilitates the development of effective responder communication strategies for incidents involving mass decontamination.
Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G. James; Williams, Richard
2014-01-01
The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) ‘Theory-based communication’: Health-focused explanations about decontamination, and sufficient practical information; 2) ‘Standard practice communication’: No health-focused explanations about decontamination, sufficient practical information; 3) ‘Brief communication’: No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with responders, which in turn resulted in higher levels of expected compliance during a real incident, and increased willingness to help other members of the public. This study shows that an understanding of the social identity approach facilitates the development of effective responder communication strategies for incidents involving mass decontamination. PMID:24595097
Braue, Ernest H; Smith, Kelly H; Doxzon, Bryce F; Lumpkin, Horace L; Clarkson, Edward D
2011-03-01
This report, the second in a series of five, directly compares the efficacy of Reactive Skin Decontamination Lotion (RSDL), the M291 Skin Decontamination Kit (SDK), 0.5% bleach (sodium or calcium hypochlorite solution), 1% soapy water, and Skin Exposure Reduction Paste Against Chemical Warfare Agents (SERPACWA) in the haired guinea pig model following exposure to soman (GD). In all experiments, guinea pigs were close-clipped and given anesthesia. In the decontamination experiments, the animals were challenged with GD and decontaminated after a 2-minute delay for the standard procedure or at longer times for the delayed-decontamination experiments. Positive control animals were challenged with GD in the same manner as the treated animals, except that they received no treatment. All animals were observed during the first 4 hours and again at 24 hours after exposure for signs of toxicity and death. The protective ratio (PR, defined as the median lethal dose [LD(50)] of the treatment group divided by the LD(50) of the untreated positive control animals) was calculated from the derived probit dose-response curves established for each treatment group and nontreated control animals. SERPACWA was applied as a thin coating (0.1 mm thick), allowed to dry for 15 minutes, and challenged with GD. After a 2-hour challenge, any remaining GD was blotted off the animal, but no additional decontamination was done. Significance in this report is defined as p <.05. Neat (undiluted) GD was used to challenge all animals in these studies. In the standard 2-minute GD decontamination experiments, the calculated PRs for RSDL, 0.5% bleach, 1% soapy water, and M291 SDK were 14, 2.7, 2.2, and 2.6, respectively. RSDL was by far the most effective decontamination product tested and significantly better than any of the other products. Bleach, soapy water, and the M291 SDK provided equivalent and modest protection. Since only RSDL provided at least good protection (PR > 5), it was the only decontamination product evaluated for delayed decontamination. In the GD delayed-decontamination experiments, the calculated LT(50) (the delayed-decontamination time at which 50% of the animals die in the test population following a 5-LD(50) challenge) value for RSDL was only 4.0 minutes. Several conclusions can be drawn from this study: 1) Reactive Skin Decontamination Lotion provided superior protection against GD compared with the other products tested; 2) The 0.5% bleach solution, the 1% soapy water solution, and the M291 SDK were less effective than RSDL, but still provided modest (2 < PR < 5) protection against GD; 3) Reactive Skin Decontamination Lotion, the best product tested, did not provide significant protection against GD when decontamination was delayed for more than 3 minutes; 4) Skin Exposure Reduction Paste Against Chemical Warfare Agents provided significant, but modest, protection against GD; 5) There was good correlation between using the rabbit model and the guinea pig model for decontamination efficacy evaluations; and 6) Soman (GD) is an agent of real concern because it is very difficult to decontaminate and the effects of exposure are difficult to treat.
Decontamination of VX, GD, and HD on a surface using modified vaporized hydrogen peroxide.
Wagner, George W; Sorrick, David C; Procell, Lawrence R; Brickhouse, Mark D; Mcvey, Iain F; Schwartz, Lewis I
2007-01-30
Vaporized hydrogen peroxide (VHP) has proven efficacy for biological decontamination and is a common gaseous sterilant widely used by industry. Regarding chemical warfare agent decontamination, VHP is also effective against HD and VX, but not GD. Simple addition of ammonia gas to VHP affords reactivity toward GD, while maintaining efficacy for HD (and bioagents) and further enhancing efficacy for VX. Thus, modified VHP is a broad-spectrum CB decontaminant suitable for fumigant-type decontamination scenarios, i.e., building, aircraft, and vehicle interiors and sensitive equipment. Finally, as an interesting aside to the current study, commercial ammonia-containing cleaners are also shown to be effective surface decontaminants for GD, but not for VX or HD.
Planetary Quarantine Annual Review, Space Technology and Research, July 1971 - July 1972
NASA Technical Reports Server (NTRS)
1973-01-01
The effects of planetary quarantine constraints are assessed for advanced missions and unmanned planetary sample return missions. Considered are natural space environment factors, post launch recontamination effects, spacecraft microbial burden estimation and prediction, and spacecraft cleaning and decontamination techniques.
Decontamination of Soil Contaminated with Bacillus anthracis ...
Technical Brief This technical summary will provide decontamination personnel rapid access to information on which decontamination approaches are most effective for soils contaminated with B anthracis.
ICU-acquired candidemia within selective digestive decontamination studies: a meta-analysis.
Hurley, James C
2015-11-01
To estimate the direct and indirect (contextual) effects of the factorized constituents of selective digestive decontamination and selective oropharyngeal decontamination (SDD/SOD), being topical antibiotic (TA) and protocolized antifungal prophylaxis (PAFP), on ICU-acquired candidemia. A broad range of ICU candidemia incidence studies were sourced to serve as points of reference. The candidemia incidence was extracted from component (control and intervention) groups decanted from studies of various designs (concurrent or non-concurrent) and whether investigating SDD/SOD versus non-TA methods of ICU infection prevention. The candidemia incidences were summarized in regression models using generalized estimating equation (GEE) methods. Groups derived from observational studies (no prevention method under study) provided an overarching external benchmark candidemia incidence for calibration. Within studies investigating SDD/SOD, the mean (and 95% confidence interval) candidemia incidence among concurrent component groups (40 control; 2.4%; 1.7-3.2% and 43 intervention groups; 2.4%; 1.6-3.1%), but not non-concurrent control groups (11 groups; 1.6%; 0.1-2.7%), is higher than that of the benchmark candidemia incidence derived from 54 observational groups (1.5%; 1.2-1.9%). The TA constituent within SDD/SOD has significant direct and indirect (contextual) effects in GEE models even after adjusting for the publication year and the group-wide presence of either candidemia risk factors or PAFP use. The TA constituent of SDD/SOD is associated with a contextual effect on candidemia incidence which is similar in magnitude to that of the conventional candidemia risk factors and against which PAFP partially attenuates. This increase is inapparent within individual SDD/SOD studies examined in isolation.
Chilcott, Robert P; Mitchell, Hannah; Matar, Hazem
2018-05-30
The UK's Initial Operational Response (IOR) is a new process for improving the survival of multiple casualties following a chemical, biological, radiological or nuclear incident. Whilst the introduction of IOR represents a patient-focused response for ambulant casualties, there is currently no provision for disrobe and dry decontamination of nonambulant casualties. Moreover, the current specialist operational response (SOR) protocol for nonambulant casualty decontamination (also referred to as "clinical decontamination") has not been subject to rigorous evaluation or development. Therefore, the aim of this study was to confirm the effectiveness of putatively optimized dry (IOR) and wet (SOR) protocols for nonambulant decontamination in human volunteers. Dry and wet decontamination protocols were objectively evaluated using human volunteers. Decontamination effectiveness was quantified by liquid chromatography-mass spectrometry analysis of the recovery of a chemical warfare agent simulant (methylsalicylate) from skin and hair of volunteers, with whole-body fluorescence imaging to quantify the skin distribution of residual simulant. Both the dry and wet decontamination processes were rapid (3 and 4 min, respectively) and were effective in removing simulant from the hair and skin of volunteers, with no observable adverse effects related to skin surface spreading of contaminant. Further studies are required to assess the combined effectiveness of dry and wet decontamination under more realistic conditions and to develop appropriate operational procedures that ensure the safety of first responders.
2007-05-10
objective is achieved through consequence management and fixed-site decontamination operations. The effectiveness of CBRN consequence management...decontamination operations. The effectiveness of CBRN consequence management and fixed-site decontamination executed in the Joint Security Area can be...when faced with Chemical, Biological, Radiological, or Nuclear (CBRN) contaminated ports of debarkation. The effectiveness of CBRN consequence
Benefits of automated surface decontamination of a radioiodine ward.
Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan
2012-02-01
A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.
Nuclear reactor cooling system decontamination reagent regeneration. [PWR; BWR
Anstine, L.D.; James, D.B.; Melaika, E.A.; Peterson, J.P. Jr.
1980-06-06
An improved method for decontaminating the coolant system of water-cooled nuclear power reactors and for regenerating the decontamination solution is described. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution.
Nuclear reactor cooling system decontamination reagent regeneration
Anstine, Larry D.; James, Dean B.; Melaika, Edward A.; Peterson, Jr., John P.
1985-01-01
An improved method for decontaminating the coolant system of water-cooled nuclear power reactors and for regenerating the decontamination solution. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution.
Barraoui, Driss; Labrecque, Michel; Blais, Jean-François
2008-03-01
Given the fact that, according to our knowledge, no study has compared the agro-environmental use of decontaminated with non-decontaminated sludge, a greenhouse experiment was carried out to test the growth of maize (Zea mays L., G-4011 Hybrid) and bioaccumulation of metals in the presence of four different sludges (MUC, QUC, BEC and DAI), before and after their decontamination by a novel process (METIX-AC). Data showed that decontaminated sludge ameliorated plant growth and biomass production, and decreased bioaccumulation of metals, more than control soil, inorganic chemical fertilization, or conventional non-decontaminated sludge. Since chemicals used by the METIX-AC process contained S and Fe, decontaminated sludge introduced large amounts of these elements, while the overall presence of metals was reduced. Often, sludge dose also affected maize growth and bioaccumulation of metals. Overall, no toxicity to plants was noticed and bioaccumulation and transfer of many metals remained below the limits reported in the literature.
Anthrax Sampling and Decontamination: Technology Trade-Offs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Phillip N.; Hamachi, Kristina; McWilliams, Jennifer
2008-09-12
The goal of this project was to answer the following questions concerning response to a future anthrax release (or suspected release) in a building: 1. Based on past experience, what rules of thumb can be determined concerning: (a) the amount of sampling that may be needed to determine the extent of contamination within a given building; (b) what portions of a building should be sampled; (c) the cost per square foot to decontaminate a given type of building using a given method; (d) the time required to prepare for, and perform, decontamination; (e) the effectiveness of a given decontamination methodmore » in a given type of building? 2. Based on past experience, what resources will be spent on evaluating the extent of contamination, performing decontamination, and assessing the effectiveness of the decontamination in abuilding of a given type and size? 3. What are the trade-offs between cost, time, and effectiveness for the various sampling plans, sampling methods, and decontamination methods that have been used in the past?« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other thanmore » lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 22,100 (114% RSD). The bulk chemistry of the DSSHT and SEHT samples does not show any signs of unusual behavior, other thanmore » lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.« less
Xu, Yunwei; Huang, Zhihong; Corner, George
2016-09-28
Corrosion of surgical instruments provides a seat for contamination and prevents proper sterilisation, placing both patients and medical staff at risk of infection. Corrosion can also compromise the structural integrity of instruments and lead to mechanical failure in use. It is essential to understand the various factors affecting corrosion resistance of surgical instruments and how it can be minimised.This paper investigates the effect on corrosion resistance from the clinical washing decontamination (WD) process, specifically by studying the changes in surface roughness and Cr/Fe ratio. Results indicate that the WD process provides a positive effect on smooth polished samples, while a lesser positive effect was observed on rough reflection reduced samples.
2006-04-01
b. Principles of Decontamination Operations. Decontaminate immediately for an agent on the skin . Perform higher levels of decontamination as a...the mask and hood with paper towels or rags. NOTE: Cool, soapy water is not as effective for removing contamination, but it can be used if you scrub ...N/A N/A 5 N/A Sponge, cellulose II Each As required N/A N/A N/A N/A 2 N/A 4 6 Brush, scrub II Each As required N/A N/A N/A N/A 2 N/A 2 N/A Towels
Understanding Contamination; Twenty Years of Simulating Radiological Contamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Emily Snyder; John Drake; Ryan James
A wide variety of simulated contamination methods have been developed by researchers to reproducibly test radiological decontamination methods. Some twenty years ago a method of non-radioactive contamination simulation was proposed at the Idaho National Laboratory (INL) that mimicked the character of radioactive cesium and zirconium contamination on stainless steel. It involved baking the contamination into the surface of the stainless steel in order to 'fix' it into a tenacious, tightly bound oxide layer. This type of contamination was particularly applicable to nuclear processing facilities (and nuclear reactors) where oxide growth and exchange of radioactive materials within the oxide layer becamemore » the predominant model for material/contaminant interaction. Additional simulation methods and their empirically derived basis (from a nuclear fuel reprocessing facility) are discussed. In the last ten years the INL, working with the Defense Advanced Research Projects Agency (DARPA) and the National Homeland Security Research Center (NHSRC), has continued to develop contamination simulation methodologies. The most notable of these newer methodologies was developed to compare the efficacy of different decontamination technologies against radiological dispersal device (RDD, 'dirty bomb') type of contamination. There are many different scenarios for how RDD contamination may be spread, but the most commonly used one at the INL involves the dispersal of an aqueous solution containing radioactive Cs-137. This method was chosen during the DARPA projects and has continued through the NHSRC series of decontamination trials and also gives a tenacious 'fixed' contamination. Much has been learned about the interaction of cesium contamination with building materials, particularly concrete, throughout these tests. The effects of porosity, cation-exchange capacity of the material and the amount of dirt and debris on the surface are very important factors. The interaction of the contaminant/substrate with the particular decontamination technology is also very important. Results of decontamination testing from hundreds of contaminated coupons have lead to certain conclusions about the contamination and the type of decontamination methods being deployed. A recent addition to the DARPA initiated methodology simulates the deposition of nuclear fallout. This contamination differs from previous tests in that it has been developed and validated purely to simulate a 'loose' type of contamination. This may represent the first time that a radiologically contaminated 'fallout' stimulant has been developed to reproducibly test decontamination methods. While no contaminant/methodology may serve as a complete example of all aspects that could be seen in the field, the study of this family of simulation methods provides insight into the nature of radiological contamination.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demmer, Rick; Boxall, Colin
Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societalmore » importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well-meaning marketers to define our decontamination problems by what products they are trying to sell; often a “one size fits all” type approach. Knowing even a little bit about the character of the decontamination problem will save time and money and increase the efficacy of decontamination.« less
1988-10-01
sample these ducts. This judgement was based on the following factors : 1. The ducts were open to the atmosphere. 2. RMA records of building area samples...selected based on several factors including piping arrangements, volume to be sampled, sampling equipment flow rates, and the flow rate necessary for...effective sampling. Therefore, each sampling point strategy and procedure was customized based on these factors . The individual specific sampling
Kumar, Vinod; Goel, Rajeev; Chawla, Raman; Silambarasan, M.; Sharma, Rakesh Kumar
2010-01-01
Chemical, biological, radiological, and nuclear (CBRN) decontamination is the removal of CBRN material from equipment or humans. The objective of the decontamination is to reduce radiation burden, salvage equipment, and materials, remove loose CBRN contaminants, and fix the remaining in place in preparation for protective storage or permanent disposal work activities. Decontamination may be carried out using chemical, electrochemical, and mechanical means. Like materials, humans may also be contaminated with CBRN contamination. Changes in cellular function can occur at lower radiation doses and exposure to chemicals. At high dose, cell death may take place. Therefore, decontamination of humans at the time of emergency while generating bare minimum waste is an enormous task requiring dedication of large number of personnel and large amount of time. General principles of CBRN decontamination are discussed in this review with emphasis on radiodecontamination. PMID:21829318
Decontamination of dental implant surface in peri-implantitis treatment: A literature review
Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.
2013-01-01
Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023
[Decontamination of chemical and biological warfare agents].
Seto, Yasuo
2009-01-01
Chemical and biological warfare agents (CBWA's) are diverse in nature; volatile acute low-molecular-weight toxic compounds, chemical warfare agents (CWA's, gaseous choking and blood agents, volatile nerve gases and blister agents, nonvolatile vomit agents and lacrymators), biological toxins (nonvolatile low-molecular-weight toxins, proteinous toxins) and microbes (bacteria, viruses, rickettsiae). In the consequence management against chemical and biological terrorism, speedy decontamination of victims, facilities and equipment is required for the minimization of the damage. In the present situation, washing victims and contaminated materials with large volumes of water is the basic way, and additionally hypochlorite salt solution is used for decomposition of CWA's. However, it still remains unsolved how to dispose large volumes of waste water, and the decontamination reagents have serious limitation of high toxicity, despoiling nature against the environments, long finishing time and non-durability in effective decontamination. Namely, the existing decontamination system is not effective, nonspecifically affecting the surrounding non-target materials. Therefore, it is the urgent matter to build up the usable decontamination system surpassing the present technologies. The symposiast presents the on-going joint project of research and development of the novel decontamination system against CBWA's, in the purpose of realizing nontoxic, fast, specific, effective and economical terrorism on-site decontamination. The projects consists of (1) establishment of the decontamination evaluation methods and verification of the existing technologies and adaptation of bacterial organophosphorus hydrolase, (2) development of adsorptive elimination technologies using molecular recognition tools, and (4) development of deactivation technologies using photocatalysis.
Kassouf, Nick; Syed, Sara; Larner, Joanne; Amlôt, Richard
2017-01-01
The UK’s Initial Operational Response (IOR) is a revised process for the medical management of mass casualties potentially contaminated with hazardous materials. A critical element of the IOR is the introduction of immediate, on-scene disrobing and decontamination of casualties to limit the adverse health effects of exposure. Ad hoc cleansing of the skin with dry absorbent materials has previously been identified as a potential means of facilitating emergency decontamination. The purpose of this study was to evaluate the in vitro oil and water absorbency of a range of materials commonly found in the domestic and clinical environments and to determine the effectiveness of a small, but representative selection of such materials in skin decontamination, using an established ex vivo model. Five contaminants were used in the study: methyl salicylate, parathion, diethyl malonate, phorate and potassium cyanide. In vitro measurements of water and oil absorbency did not correlate with ex vivo measurements of skin decontamination. When measured ex vivo, dry decontamination was consistently more effective than a standard wet decontamination method (“rinse-wipe-rinse”) for removing liquid contaminants. However, dry decontamination was ineffective against particulate contamination. Collectively, these data confirm that absorbent materials such as wound dressings and tissue paper provide an effective, generic capability for emergency removal of liquid contaminants from the skin surface, but that wet decontamination should be used for non-liquid contaminants. PMID:28152053
Virji, M Abbas; Woskie, Susan R; Pepper, Lewis D
2009-02-01
A 2005 regulatory review of the lead in construction standard by the Occupational Safety and Health Administration (OSHA) noted that alternative pathways of exposure can be as significant as inhalation exposure and that noncompliance with the standard pertaining to hygiene facilities and practices was the second most commonly violated section of the standard. Noncompliance with provisions of the standard and unhealthy work and hygiene practices likely increase the likelihood of take-home lead via contaminated clothing, automobiles, and skin, thus contributing to elevated blood lead levels (BLL) among construction workers and their family members. We performed a cross-sectional study of bridge painters working for small contractors in Massachusetts to investigate causes of persistent elevated BLLs and to assess lead exposures. Thirteen work sites were evaluated for a 2-week period during which surface and skin wipe samples were collected and qualitative information was obtained on personal hygiene practices, decontamination and hand wash facilities, and respiratory protection programs. Results showed lead contamination on workers' skin, respirators, personal automobiles, and the decontamination unit, indicating a significant potential for take-home lead exposure. Overall, the geometric mean (GM) skin lead levels ranged from 373 microg on workers' faces at end of shift to 814 microg on hands at break time. The overall GM lead level inside respirators was 143 microg before work and 286 microg after work. Lead contamination was also present inside workers' personal vehicles as well as on surfaces inside the clean side of the decontamination unit. Review of the respiratory protection programs, work site decontamination and hand wash facilities, and personal hygiene practices indicated that these factors had significant impact on skin and surface contamination levels and identified significant opportunities for improving work site facilities and personal practices. Elevated lead exposure and BLL can be minimized by strict adherence to the OSHA provisions for functioning decontamination and hygiene facilities and healthy personal hygiene practices.
Love, Adam H; Bailey, Christopher G; Hanna, M Leslie; Hok, Saphon; Vu, Alex K; Reutter, Dennis J; Raber, Ellen
2011-11-30
Bench-scale testing was used to evaluate the efficacy of four decontamination formulations on typical indoor surfaces following exposure to the liquid chemical warfare agents sarin (GB), soman (GD), sulfur mustard (HD), and VX. Residual surface contamination on coupons was periodically measured for up to 24h after applying one of four selected decontamination technologies [0.5% bleach solution with trisodium phosphate, Allen Vanguard Surface Decontamination Foam (SDF™), U.S. military Decon Green™, and Modec Inc. and EnviroFoam Technologies Sandia Decontamination Foam (DF-200)]. All decontamination technologies tested, except for the bleach solution, performed well on nonporous and nonpermeable glass and stainless-steel surfaces. However, chemical agent residual contamination typically remained on porous and permeable surfaces, especially for the more persistent agents, HD and VX. Solvent-based Decon Green™ performed better than aqueous-based bleach or foams on polymeric surfaces, possibly because the solvent is able to penetrate the polymer matrix. Bleach and foams out-performed Decon Green for penetrating the highly polar concrete surface. Results suggest that the different characteristics needed for an ideal and universal decontamination technology may be incompatible in a single formulation and a strategy for decontaminating a complex facility will require a range of technologies. Copyright © 2011 Elsevier B.V. All rights reserved.
Elias, Shlomi; Saphier, Sigal; Columbus, Ishay; Zafrani, Yossi
2014-01-01
Among the chemical warfare agents, the extremely toxic nerve agent VX (O-ethyl S-2-(diisopropylamino)ethyl methylphosphonothioate) is a target of high importance in the development of decontamination methods, due to its indefinite persistence on common environmental surfaces. Liquid decontaminants are mostly characterized by high corrosivity, usually offer poor coverage, and tend to flow and accumulate in low areas. Therefore, the development of a noncorrosive decontaminant, sufficiently viscous to resist dripping from the contaminated surface, is necessary. In the present paper we studied different polysaccharides-thickened fluoride aqueous solutions as noncorrosive decontaminants for rapid and efficient VX degradation to the nontoxic product EMPA (ethyl methylphosphonic acid). Polysaccharides are environmentally benign, natural, and inexpensive. Other known decontaminants cannot be thickened by polysaccharides, due to the sensitivity of the latter toward basic or oxidizing agents. We found that the efficiency of VX degradation in these viscous solutions in terms of kinetics and product identity is similar to that of KF aqueous solutions. Guar gum (1.5 wt %) with 4 wt % KF was chosen for further evaluation. The benign nature, rheological properties, adhering capabilities to different surfaces, and decontamination from a porous matrix were examined. This formulation showed promising properties for implementation as a spray decontaminant for common and sensitive environmental surfaces.
Decontamination and management of human remains following incidents of hazardous chemical release.
Hauschild, Veronique D; Watson, Annetta; Bock, Robert
2012-01-01
To provide specific guidance and resources for systematic and orderly decontamination of human remains resulting from a chemical terrorist attack or accidental chemical release. A detailed review and health-based decision criteria protocol is summarized. Protocol basis and logic are derived from analyses of compound-specific toxicological data and chemical/physical characteristics. Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present, such as sites of transportation accidents, terrorist operations, or medical examiner processing points. Guidance is developed from data-characterizing controlled experiments with laboratory animals, fabrics, and materiel. Logic and specific procedures for decontamination and management of remains, protection of mortuary affairs personnel, and decision criteria to determine when remains are sufficiently decontaminated are presented. Established procedures as well as existing materiel and available equipment for decontamination and verification provide reasonable means to mitigate chemical hazards from chemically exposed remains. Unique scenarios such as those involving supralethal concentrations of certain liquid chemical warfare agents may prove difficult to decontaminate but can be resolved in a timely manner by application of the characterized systematic approaches. Decision criteria and protocols to "clear" decontaminated remains for transport and processing are also provided. Once appropriate decontamination and verification have been accomplished, normal procedures for management of remains and release can be followed.
Misik, Jan; Jost, Petr; Pavlikova, Ruzena; Vodakova, Eva; Cabal, Jiri; Kuca, Kamil
2013-06-01
The genotoxic vesicant sulphur mustard [bis-2-(chloroethyl)sulphide] is a chemical warfare agent which is easily available due to its relatively simple synthesis. Thus, sulphur mustard is a potential agent for mass contamination. In this study, we focused on sulphur mustard toxicity and decontamination in a rat model using commercially available detergent mixtures for dermal decontamination. Male Wistar rats were percutaneously treated with sulphur mustard and subjected to wet decontamination 2 min postexposure. Commercially produced detergents Neodekont™, Argos™, Dermogel™ and FloraFree™ were tested for their decontamination efficacy against an exposed group and their protective ratios determined. The results showed that all tested detergent solutions produced an increase in the median lethal dose [LD(50) = 9.83 (5.87-13.63) mg·kg(-1)] in comparison to controls, which led to increased survival of experimental animals. In general, all tested detergents provided modest decontamination efficacy (PR = 2.0-5.7). The highest protective ratio (5.7) was consistently achieved with Argos™. Accordingly, Argos™ should be considered in further investigation of mass casualty decontamination.
Gravett, M R; Hopkins, F B; Self, A J; Webb, A J; Timperley, C M; Riches, J R
2014-08-01
In the event of alleged use of organophosphorus nerve agents, all kinds of environmental samples can be received for analysis. These might include decontaminated and charred matter collected from the site of a suspected chemical attack. In other scenarios, such matter might be sampled to confirm the site of a chemical weapon test or clandestine laboratory decontaminated and burned to prevent discovery. To provide an analytical capability for these contingencies, we present a preliminary investigation of the effect of accelerant-based fire and liquid decontamination on soil contaminated with the nerve agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). The objectives were (a) to determine if VX or its degradation products were detectable in soil after an accelerant-based fire promoted by aviation fuel, including following decontamination with Decontamination Solution 2 (DS2) or aqueous sodium hypochlorite, (b) to develop analytical methods to support forensic analysis of accelerant-soaked, decontaminated and charred soil and (c) to inform the design of future experiments of this type to improve analytical fidelity. Our results show for the first time that modern analytical techniques can be used to identify residual VX and its degradation products in contaminated soil after an accelerant-based fire and after chemical decontamination and then fire. Comparison of the gas chromatography-mass spectrometry (GC-MS) profiles of VX and its impurities/degradation products from contaminated burnt soil, and burnt soil spiked with VX, indicated that the fire resulted in the production of diethyl methylphosphonate and O,S-diethyl methylphosphonothiolate (by an unknown mechanism). Other products identified were indicative of chemical decontamination, and some of these provided evidence of the decontaminant used, for example, ethyl 2-methoxyethyl methylphosphonate and bis(2-methoxyethyl) methylphosphonate following decontamination with DS2. Sample preparation procedures and analytical methods suitable for investigating accelerant and decontaminant-soaked soil samples are presented. VX and its degradation products and/or impurities were detected under all the conditions studied, demonstrating that accelerant-based fire and liquid-based decontamination and then fire are unlikely to prevent the retrieval of evidence of chemical warfare agent (CWA) testing. This is the first published study of the effects of an accelerant-based fire on a CWA in environmental samples. The results will inform defence and security-based organisations worldwide and support the verification activities of the Organisation for the Prohibition of Chemical Weapons (OPCW), winner of the 2013 Nobel Peace Prize for its extensive efforts to eliminate chemical weapons.
Decontamination and Management of Human Remains Following Incidents of Hazardous Chemical Release
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hauschild, Veronique; Watson, Annetta Paule; Bock, Robert Eldon
2012-01-01
Abstract Objective: To provide specific procedural guidance and resources for identification, assessment, control, and mitigation of compounds that may contaminate human remains resulting from chemical attack or release. Design: A detailed technical, policy, and regulatory review is summarized. Setting: Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present. Settings would include sites of transportation accidents, natural disasters, terrorist or military operations, mortuary affairs or medical examiner processing and decontamination points, and similar. Patients, Participants: While recommended procedures have not been validated with actual human remains, guidance has been developed frommore » data characterizing controlled experiments with fabrics, materiel, and laboratory animals. Main Outcome Measure(s): Presentation of logic and specific procedures for remains management, protection and decontamination of mortuary affairs personnel, as well as decision criteria for determining when remains are sufficiently decontaminated so as to pose no chemical health hazard. Results: Established procedures and existing equipment/materiel available for decontamination and verification provide appropriate and reasonable means to mitigate chemical hazards from remains. Extensive characterization of issues related to remains decontamination indicates that supra-lethal concentrations of liquid chemical warfare agent VX may prove difficult to decontaminate and verify in a timely fashion. Specialized personnel can and should be called upon to assist with monitoring necessary to clear decontaminated remains for transport and processing. Conclusions: Once appropriate decontamination and verification have been accomplished, normal procedures for remains processing and transport to the decedent s family and the continental United States can be followed.« less
Pichler, G; Pux, C; Babeluk, R; Hermann, B; Stoiser, E; De Campo, A; Grisold, A; Zollner-Schwetz, I; Krause, R; Schippinger, W
2018-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) decontamination regimens predominantly use chlorhexidine bathing in combination with mupirocin nasal ointment. However, resistances in Staphylococcus aureus strains are increasingly common and there is a need of alternative, safe and feasible protocols. This interventional cohort study performed at the Albert Schweitzer Hospital in Graz, Austria, aimed to (1) determine MRSA prevalence at different body sites and (2) assess the efficacy of the decontamination using octenidine-based leave-on products added to existing robust infection control measures. All inpatients of this tertiary care hospital being treated in geriatric medical wards (GWs) and apallic care units (ACUs) were screened for MRSA and decontamination rates were determined after one, two or three decontamination cycles, respectively. At baseline, MRSA was detected in 25 of the 126 patients screened (19.8%). We found MRSA in 13/126 (10.3%) swabs from nasal vestibules, in 12/126 (9.5%) skin swabs, in 11/51 (21.6%) swabs from PEG-stomata or suprapubic catheters and in 8/13 (61.5%) tracheostomata swabs. A maximum of three 5-day decontamination cycles reduced the number of MRSA positive patients by 68.0%. Excluding non-compliant and deceased patients, decontamination reduced MRSA carriage by 93.3% (n = 15). No adverse events related to the applied decontamination regimen occurred. Exclusive screening of the nose might underreport MRSA prevalence rates. In this study, decontamination with octenidine-based leave-on products was safe and effective in a critical patient population.
Hui, Xiaoying; Lamel, Sonia; Qiao, Peter; Maibach, Howard I
2013-03-01
Cutaneously directed chemical warfare agents can elicit significant morbidity and mortality. The optimization of prophylactic and therapeutic interventions counteracting these agents is crucial, and the development of decontamination protocols and methodology of post dermal exposure risk assessments would be additionally applicable to common industrial and consumer dermatotoxicants. Percutaneous (PC) penetration is often considered a simple one-step diffusion process but presently consists of at least 15 steps. The systemic exposure to an agent depends on multiple factors and the second part of this review covers absorption and excretion kinetics, wash and rub effects, skin substantivity and transfer, among others. Importantly, the partitioning behavior and diffusion through the stratum corneum (SC) of a wide physicochemical array of compounds shows that many compounds have approximately the same diffusion coefficient which determines their percutaneous absorption in vivo. After accounting for anatomical variation of the SC, the penetration flux value of a substance depends mainly on its SC/vehicle partition coefficient. Additionally, the SC acts as a 'reservoir' for topically applied molecules, and tape stripping methodology can quantify the remaining chemical in the SC which can predict the total molecular penetration in vivo. The determination of ideal decontamination protocols is of utmost importance to reduce morbidity and mortality. However, even expeditious standard washing procedures post dermal chemical exposure often fails to remove chemicals. The second part of this overview continues to review percutaneous penetration extending insights into the complexities of penetration, decontamination and potential newer assays that may be of practical importance. Copyright © 2012 John Wiley & Sons, Ltd.
Contamination control through filtration of microorganisms
NASA Technical Reports Server (NTRS)
Stabekis, P. D.; Lyle, R. G.
1972-01-01
A description is given of the various kinds of gas and liquid filters used in decontamination and sterilization procedures. Also discussed are filtration mechanisms, characteristics of filter materials, and the factors affecting filter performance. Summaries are included for filter testing and evaluation techniques and the possible application of the filters to spacecraft sterilization.
Cold plasma rapid decontamination of food contact surfaces contaminated with Salmonella biofilms
USDA-ARS?s Scientific Manuscript database
Cross-contamination of fresh produce and other foods from persistent pathogen reservoirs is a known risk factor in processing environments. Industry requires a rapid, waterless, zero-contact, chemical-free method for removing pathogens from food-contact surfaces. Cold plasma was tested for its abili...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iseki, Tadahiro; Inaba, Makoto; Takahashi, Naoki
During the second and third steps of Active Test at Rokkasho Reprocessing Plant (RRP), the performances of the Separation Facility have been checked; (A) diluent washing efficiency, (B) plutonium stripping efficiency, (C) decontamination factor of fission products and (D) plutonium and uranium leakage into raffinate and spent solvent. Test results were equivalent to or better than expected. (authors)
Assessing Ecosystem Impacts from Simulant and Decontaminant Use
1988-05-01
on the relationship between metak- olism and body weight, W: DMAN = DANIMAL (WANIMAL/WMAN) 0.25 (7) Values of the scaling factor, (WANIMAL/WMAN)P’ 25...chemical. Structure-activity analysis is a relatively new field, and the available tools are still crude. The user must exercise scientific judgment in
Farrell, H P; Garvey, M; Cormican, M; Laffey, J G; Rowan, N J
2010-05-01
To investigate critical electrical and biological factors governing the efficacy of pulsed light (PL) for the in vitro inactivation of bacteria isolated from the clinical environment. Development of this alternative PL decontamination approach is timely, as the incidence of health care-related infections remains unacceptably high. Predetermined cell numbers of clinically relevant Gram-positive and Gram-negative bacteria were inoculated separately on agar plates and were flashed with
Long lasting decontamination foam
Demmer, Ricky L.; Peterman, Dean R.; Tripp, Julia L.; Cooper, David C.; Wright, Karen E.
2010-12-07
Compositions and methods for decontaminating surfaces are disclosed. More specifically, compositions and methods for decontamination using a composition capable of generating a long lasting foam are disclosed. Compositions may include a surfactant and gelatin and have a pH of less than about 6. Such compositions may further include affinity-shifting chemicals. Methods may include decontaminating a contaminated surface with a composition or a foam that may include a surfactant and gelatin and have a pH of less than about 6.
Symposium on Toxic Substance Control: Decontamination, April 22 - 24, 1980, Columbus, Ohio.
1981-06-01
standard decontaminants is used. TABLE 1. Standard Chemical Decontaminants Decontaminant Agents Used On STB Blister and nerve agents DS-2 All chemical... agents M258 Kit Sodium Hydroxide, Ethanol, G-Series nerve agents Phenol, Water Chloramine B, ZnCI2, Blister ana V-Series Ethanol, Water nerve agents A...is a point source alarm that actively samples ambient air and reacts to low concentrations of nerve agents . The M-8 alarm detector also detects several
2016-01-01
DC) product following cutaneous exposure to VX was affected by the DC procedure. Fur-clipped, male, unanesthetized guinea pigs were used as subjects...RSDL) Following Cutaneous VX Exposure in Guinea Pigs Irwin Koplovitz Susan Schulz Julia Morgan Robert Reed Edward Clarkson C. Gary Hurst...Decontamination Procedures Using Reactive Skin 5a. CONTRACT NUMBER Decontamination Lotion (RSDL) Following Cutaneous VX Exposure in Guinea Pigs 5b
1988-12-30
LIMITING ACTIVATED ZOLUTION OF HYPOCHLORITE), SADS (SURFACE ACTIVE DISPLACEMENT SYSTEMS ), SACRIFICIAL COAT!ý:GS, MICRO EMULSIONS , DS2, STB SLURRY...CURRENT SYSTEMS AND THOSE IN DEVELOPMENT WITH NOT MEET ALL DECONTAMINATION NEEDS. ITEMS TO BE FIELDED WILL INCLUDE: AN EMULSION BSED DECONTAMINATION...DECONTAMINATION SYSTEM FOR AIRCRAFT EXTERIORS; MICROEMULSIONS CONTAINING REACTIVE DECONTAMINANTS (FORMULATION, EFFICACY, AND 181 OPTIMIZATION); COOLING OF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joiner, R.L.; Keys, W.B.; Harroff, H.H.
1988-02-18
A task was assigned to Battelle's Medical Research and Evaluation Facility(MREF) to evaluate the effectiveness of two candidate decontamination systems when compared to the standard dual component M258A1 decontamination system currently fielded by the U.S. Army. The chemical surety material (CSM) used in the evaluation were the organophosphates Soman (GD), polymer thickened GD (TGD), and VX, and the vesicants sulfur mustard (HD) and Lewisite (LS). The efficacies of the two candidate decontamination systems were evaluated in such a manner as to determine the LD50 and protective ratio (PR) for each decontaminant against each organophosphate CSM as compared to the standardmore » M258A1 decontamination system LD50. The PR constituted a comparison for each candidate system against the M258A1 standard. In the vesicant phase of the screen, the efficacies of the candidate systems were evaluated in a side-by-side comparison to the M258A1 decontamination system to determine whether the candidates were as good as or better than the standard dual component system.« less
Planning guidance for nuclear-power-plant decontamination. [PWR; BWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munson, L.F.; Divine, J.R.; Martin, J.B.
1983-06-01
Direct and indirect costs of decontamination are considered in the benefit-cost analysis. A generic form of the benefit-cost ratio is evaluated in monetary and nonmonetary terms, and values of dollar per man-rem are cited. Federal and state agencies that may have jurisiction over various aspects of decontamination and waste disposal activities are identified. Methods of decontamination, their general effectiveness, and the advantages and disadvantages of each are outlined. Dilute or concentrated chemical solutions are usually used in-situ to dissolve the contamination layer and a thin layer of the underlying substrate. Electrochemical techniques are generally limited to components but show highmore » decontamination effectiveness with uniform corrosion. Mechanical agents are particularly appropriate for certain out-of-system surfaces and disassembled parts. These processes are catagorized and specific concerns are discussed. The treatment, storage, and disposal or discharge or discharge of liquid, gaseous, and solid wastes generated during the decontamination process are discussed. Radioactive and other hazardous chemical wastes are considered. The monitoring, treatment, and control of radioactive and nonradioactive effluents, from both routine operations and possible accidents, are discussed. Protecting the health and safety of personnel onsite during decontamination is of prime importance and should be considered in each facet of the decontamination process. The radiation protection philosophy of reducing exposure to levels as low as reasonably achievable should be stressed. These issues are discussed.« less
Bashir, Mina; Ahmed, Mahjabeen; Weinmaier, Thomas; Ciobanu, Doina; Ivanova, Natalia; Pieber, Thomas R.; Vaishampayan, Parag A.
2016-01-01
Strict planetary protection practices are implemented during spacecraft assembly to prevent inadvertent transfer of earth microorganisms to other planetary bodies. Therefore, spacecraft are assembled in cleanrooms, which undergo strict cleaning and decontamination procedures to reduce total microbial bioburden. We wanted to evaluate if these practices selectively favor survival and growth of hardy microorganisms, such as pathogens. Three geographically distinct cleanrooms were sampled during the assembly of three NASA spacecraft: The Lockheed Martin Aeronautics' Multiple Testing Facility during DAWN, the Kennedy Space Center's Payload Hazardous Servicing Facility (KSC-PHSF) during Phoenix, and the Jet Propulsion Laboratory's Spacecraft Assembly Facility during Mars Science Laboratory. Sample sets were collected from the KSC-PHSF cleanroom at three time points: before arrival of the Phoenix spacecraft, during the assembly and testing of the Phoenix spacecraft, and after removal of the spacecraft from the KSC-PHSF facility. All samples were subjected to metagenomic shotgun sequencing on an Illumina HiSeq 2500 platform. Strict decontamination procedures had a greater impact on microbial communities than sampling location Samples collected during spacecraft assembly were dominated by Acinetobacter spp. We found pathogens and potential virulence factors, which determine pathogenicity in all the samples tested during this study. Though the relative abundance of pathogens was lowest during the Phoenix assembly, potential virulence factors were higher during assembly compared to before and after assembly, indicating a survival advantage. Decreased phylogenetic and pathogenic diversity indicates that decontamination and preventative measures were effective against the majority of microorganisms and well implemented, however, pathogen abundance still increased over time. Four potential pathogens, Acinetobacter baumannii, Acinetobacter lwoffii, Escherichia coli and Legionella pneumophila, and their corresponding virulence factors were present in all cleanroom samples. This is the first functional metagenomics study describing presence of pathogens and their corresponding virulence factors in cleanroom environments. The results of this study should be considered for microbial monitoring of enclosed environments such as schools, homes, hospitals and more isolated habitation such the International Space Station and future manned missions to Mars. PMID:27667984
DISPOSAL OF RESIDUES FROM BUILDING DECONTAMINATION ACTIVITIES
After a building has gone through decontamination activities from a chemical attack there will be a significant amount of building decontamination residue that will need to undergo disposal. This project consists of a fundamental study to investigate the desorption of simulated c...
Braue, Ernest H; Smith, Kelly H; Doxzon, Bryce F; Lumpkin, Horace L; Clarkson, Edward D
2011-03-01
This report, first in a series of five, directly compares the efficacy of 4 decontamination products and Skin Exposure Reduction Paste Against Chemical Warfare Agents (SERPACWA) in the haired guinea pig model following exposure to VX. In all experiments, guinea pigs were close-clipped and given anesthesia. In the decontamination experiments, the animals were challenged with VX and decontaminated after a 2-minute delay for the standard procedure or at longer times for the delayed-decontamination experiments. Skin Exposure Reduction Paste Against Chemical Warfare Agents was applied as a thin coating (0.1 mm thick), allowed to dry for 15 minutes, and challenged with VX. After a 2-hour challenge, any remaining VX was blotted off the animal, but no additional decontamination was done. Positive control animals were challenged with VX in the same manner as the treated animals, except that they received no treatment. In addition, the positive control animals were always challenged with 5% VX in isopropyl alcohol (IPA) solution, whereas the treatment animals received either neat (undiluted) VX or 5% VX in IPA solution. All animals were observed during the first 4 hours and again at 24 hours after exposure for signs of toxicity and death. The protective ratio (PR, defined as the median lethal dose [LD(50)] of the treatment group divided by the LD(50) of the untreated positive control animals) was calculated from the probit dose-response curves established for each treatment group and nontreated control animals. Significance in this report was defined as p < .05. In the standard 2-minute neat VX decontamination experiments, the calculated PRs for Reactive Skin Decontamination Lotion (RSDL), 0.5% bleach, 1% soapy water, and the M291 Skin Decontamination Kit (SDK) were 66, 17, 16, and 1.1, respectively. Reactive Skin Decontamination Lotion was by far the most effective decontamination product tested and was significantly better than any of the other products. Bleach and soapy water provided equivalent and good (PR > 5) protection. They were both significantly better than the M291 SDK. The M291 SDK did not provide significant protection compared with positive controls. In the neat VX delayed-decontamination experiments, the calculated LT(50) (the delayed-decontamination time at which 50% of the animals died in the test population following a 5-LD(50) challenge) values for RSDL, 0.5% bleach, and 1% soapy water were 31, 48, and 26 minutes, respectively. The results showed that SERPACWA provided significant, but modest (PR < 5), protection against neat VX, with a PR of 2.1. Several conclusions can be drawn from this study: 1) RSDL provided superior protection against VX compared with the other products tested; 2) 0.5% bleach and 1% soapy water were less effective than RSDL, but still provided good protection against VX; 3) the M291 SDK was the least effective decontamination product and did not provide significant protection against VX; 4) the agent was observed to streak when using the M291 SDK, and efficacy may improve if the agent is first blotted, followed by wiping with a new or clean part of the M291 SDK pad; 5) RSDL, 0.5% bleach, and 1% soapy water provided significant protection against a 5-LD(50) challenge of VX, even when decontamination was delayed for up to about 30 minutes; and 6) SERPACWA provided significant, but modest, protection against VX.
Ayabe, Yoshiko; Hijii, Naoki; Takenaka, Chisato
2017-09-01
We investigated whether local-scale decontamination (removal of the litter layer, superficial soil layer, and understory) in a secondary forest contaminated by the Fukushima nuclear power plant accident reduced 137 Cs contamination of the soil and litter. We also measured 137 Cs concentrations in plants and in the web-building spider Nephila clavata (Nephilidae: Arachnida), as an indicator species, to examine 137 Cs contamination in arthropods. One month after decontamination, the total 137 Cs contamination (soil + litter) was reduced by 20% (100 kBq·m -2 ) relative to that in an adjacent untreated (i.e., contaminated) area, which was however not statistically significant. Four months after decontamination, 137 Cs in the decontaminated area had increased to a level similar to those in the untreated area, and the air radiation dose in the decontaminated area was about 2.1 μSv·h -1 , significantly higher than that in the untreated area (1.9 μSv·h -1 ). This may have been attributed to a torrential rain event. Although no statistically significant reduction was observed, most spiders had a lower 137 Cs contamination than that before the decontamination. This implied that the decontamination may have reduced 137 Cs transfer from soil via litter to N. clavata through the detrital food chains, but may not have reduced the amount of 137 Cs transfer through grazing food chains because the concentration of 137 Cs in living tree leaves was not reduced by the decontamination. In autumn, about 2 kBq·m -2 of 137 Cs was supplied from foliage to the ground by litterfall. The results suggested that removal of the litter and superficial soil layers in a contaminated forest may be ineffective. The present study suggests that the local-scale decontamination in a secondary forest had no effect on the reduction of 137 Cs contamination in the treated area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reducing Risk of Salmonellosis through Egg Decontamination Processes.
Keerthirathne, Thilini Piushani; Ross, Kirstin; Fallowfield, Howard; Whiley, Harriet
2017-03-22
Eggs have a high nutritional value and are an important ingredient in many food products. Worldwide foodborne illnesses, such as salmonellosis linked to the consumption of eggs and raw egg products, are a major public health concern. This review focuses on previous studies that have investigated the procedures for the production of microbiologically safe eggs. Studies exploring pasteurization and decontamination methods were investigated. Gamma irradiation, freeze drying, hot air, hot water, infra-red, atmospheric steam, microwave heating and radiofrequency heating are all different decontamination methods currently considered for the production of microbiologically safe eggs. However, each decontamination procedure has different effects on the properties and constituents of the egg. The pasteurization processes are the most widely used and best understood; however, they influence the coagulation, foaming and emulsifying properties of the egg. Future studies are needed to explore combinations of different decontamination methods to produce safe eggs without impacting the protein structure and usability. Currently, eggs which have undergone decontamination processes are primarily used in food prepared for vulnerable populations. However, the development of a decontamination method that does not affect egg properties and functionality could be used in food prepared for the general population to provide greater public health protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watkins, R.M.
1959-03-01
Developments relative to decontamination achieved under the Yankee Reasearch and Development program are reported. The decontamination of a large test loop which had been used to conduct corrosion rate studies for the Yankee reactor program is described. The basic permanganate-citrate decontamination procedure suggested for application in Yankee reactor primary system cleanup was used. A study of the chemistry of this decontamination operation is presented, together with conclusions pertaining to the effectiveness of the solutions under the conditions studied. In an attempt to further improve the efficiency of the procedure, an additional series of static and dynamic tests was performcd usingmore » contaminated sections of stainless steel tubing from the original SlW steam generator. Survival variables in the process (reagent composition, contact time, temperature, and flow velocity) were studied. The changes in decontamination efficiency produced by these variations are discussed and compared with results obtained throughthe use of similar procedures. Based on the observations made, conclusions are drawn concerning the optimum conditions for this cleanup process, a new set of suggested basic permanganate-citrate decontamination instructions is presented, and recommendations are made concerning future studies involving this procedure. (auth)« less
Reducing Risk of Salmonellosis through Egg Decontamination Processes
Keerthirathne, Thilini Piushani; Ross, Kirstin; Fallowfield, Howard; Whiley, Harriet
2017-01-01
Eggs have a high nutritional value and are an important ingredient in many food products. Worldwide foodborne illnesses, such as salmonellosis linked to the consumption of eggs and raw egg products, are a major public health concern. This review focuses on previous studies that have investigated the procedures for the production of microbiologically safe eggs. Studies exploring pasteurization and decontamination methods were investigated. Gamma irradiation, freeze drying, hot air, hot water, infra-red, atmospheric steam, microwave heating and radiofrequency heating are all different decontamination methods currently considered for the production of microbiologically safe eggs. However, each decontamination procedure has different effects on the properties and constituents of the egg. The pasteurization processes are the most widely used and best understood; however, they influence the coagulation, foaming and emulsifying properties of the egg. Future studies are needed to explore combinations of different decontamination methods to produce safe eggs without impacting the protein structure and usability. Currently, eggs which have undergone decontamination processes are primarily used in food prepared for vulnerable populations. However, the development of a decontamination method that does not affect egg properties and functionality could be used in food prepared for the general population to provide greater public health protection. PMID:28327524
Existing decontamination procedures are time-consuming, labor-intensive, and produce low-yielding results, and they have a high risk of personnel exposure and equipment damage. Foster-Miller, Inc., has teamed with Lawrence Livermore National Laboratory and other reagent suppl...
Integrated decontamination process for metals
Snyder, Thomas S.; Whitlow, Graham A.
1991-01-01
An integrated process for decontamination of metals, particularly metals that are used in the nuclear energy industry contaminated with radioactive material. The process combines the processes of electrorefining and melt refining to purify metals that can be decontaminated using either electrorefining or melt refining processes.
Dataset shows the calculation of reported decontamination efficacies from the raw data (i.e., measured amount of chemical recovered from test coupons and positive controls) to actual decontamination efficacy for all chemicals and decontaminantsThis dataset is associated with the following publication:Oudejans , L., J. O'Kelly, A. Evans, B. Barbara Wyrzykowska-Ceradini, A. Toauati, D. Tabor , and E. Snyder. Efficacy of decontaminant solutions for remediation on TICs on PPE materials. JOURNAL OF HAZARDOUS MATERIALS. Elsevier Science Ltd, New York, NY, USA, 1-5, (2016).
2000-12-01
interpretation of the May 7, 1996 meeting with Carl Olson, Tim Hayes, Tom Dreier, Dave Stitcher , and Frances Reid. This procedure of decontamination and proof...with Carl Olson, Tim Hayes, Tom Dreier, Dave Stitcher , and Frances Reid. TASK 33 DECONTAMINATION PROCEDURE AND PROOF OF DECONTAMINATION Decontamination...two of you, Mr. Stitcher and Dr. Estep to share our results and resolve any safety issues. Thanks, and M-3 have a good weekend! John S. Graham John S
Tucker, Mark D [Albuquerque, NM
2011-09-20
A reduced weight decontamination formulation that utilizes a solid peracid compound (sodium borate peracetate) and a cationic surfactant (dodecyltrimethylammonium chloride) that can be packaged with all water removed. This reduces the packaged weight of the decontamination formulation by .about.80% (as compared to the "all-liquid" DF-200 formulation) and significantly lowers the logistics burden on the warfighter. Water (freshwater or saltwater) is added to the new decontamination formulation at the time of use from a local source.
2016-01-01
products in the haired guinea pig model following exposure to GF (EA1212). 15. SUBJECT TERMS decontamination, delayed decontamination, Reactive Skin...the four listed decontamination products in the haired guinea pig model following exposure to GF (EA1212). In all experiments, guinea pigs were close...the four listed decontamination products and SERPACWA in the haired guinea pig model following exposure to GF [cyclosarin, EA1212, Cyclohexyl
2016-01-01
listed decontamination products in the haired guinea pig model following exposure to VR (Russian VX, EA4243). 15. SUBJECT TERMS decontamination...the efficacy of the barrier skin cream SERPACWA and the four listed decontamination products in the haired guinea pig model following exposure to VR...four listed decontamination products and SERPACWA in the haired guinea pig model following exposure to VR (Russian VX, EA4243, Soviet V-gas
Material Compatibility for Historic Items Decontaminated with ...
Report This project continued research of the effects of decontamination methods for biological agents on materials identified as representative of types of irreplaceable objects or works of art found in museums and/or archive settings. In the previous research, surrogate materials were checked for compatibility with four decontamination methods: chlorine dioxide, hydrogen peroxide vapor, methyl bromide, and ethylene oxide gas. This project investigated the effects of gamma irradiation, which has also been shown to be an effective decontamination method for biological agents, on the surrogate test materials.
Pruvost, Mélanie; Bennett, E. Andrew; Grange, Thierry; Geigl, Eva-Maria
2010-01-01
Background PCR amplification of minute quantities of degraded DNA for ancient DNA research, forensic analyses, wildlife studies and ultrasensitive diagnostics is often hampered by contamination problems. The extent of these problems is inversely related to DNA concentration and target fragment size and concern (i) sample contamination, (ii) laboratory surface contamination, (iii) carry-over contamination, and (iv) contamination of reagents. Methodology/Principal Findings Here we performed a quantitative evaluation of current decontamination methods for these last three sources of contamination, and developed a new procedure to eliminate contaminating DNA contained in PCR reagents. We observed that most current decontamination methods are either not efficient enough to degrade short contaminating DNA molecules, rendered inefficient by the reagents themselves, or interfere with the PCR when used at doses high enough to eliminate these molecules. We also show that efficient reagent decontamination can be achieved by using a combination of treatments adapted to different reagent categories. Our procedure involves γ- and UV-irradiation and treatment with a mutant recombinant heat-labile double-strand specific DNase from the Antarctic shrimp Pandalus borealis. Optimal performance of these treatments is achieved in narrow experimental conditions that have been precisely analyzed and defined herein. Conclusions/Significance There is not a single decontamination method valid for all possible contamination sources occurring in PCR reagents and in the molecular biology laboratory and most common decontamination methods are not efficient enough to decontaminate short DNA fragments of low concentration. We developed a versatile multistrategy decontamination procedure for PCR reagents. We demonstrate that this procedure allows efficient reagent decontamination while preserving the efficiency of PCR amplification of minute quantities of DNA. PMID:20927390
Timing of decontamination and treatment in case of percutaneous VX poisoning: a mini review.
Joosen, Marloes J A; van der Schans, Marcel J; Kuijpers, Willem C; van Helden, Herman P M; Noort, Daan
2013-03-25
Low volatile organophosphorous nerve agents such as VX, will most likely enter the body via the skin. The pharmacokinetics of drugs such as oximes, atropine and diazepam, are not aligned with the variable and persistent toxicokinetics of the agent. Repeated administration of these drugs showed to improve treatment efficacy compared to a single injection treatment. Because of the effectiveness of continuous treatment, it was investigated to what extent a subchronic pretreatment with carbamate (pyridostigmine or physostigmine combined with either procyclidine or scopolamine) would protect against percutaneous VX exposure. Inclusion of scopolamine in the pretreatment prevented seizures in all animals, but none of the pretreatments affected survival time or the onset time of cholinergic signs. These results indicate that percutaneous poisoning with VX requires additional conventional treatment in addition to the current pretreatment regimen. Decontamination of VX-exposed skin is one of the most important countermeasures to mitigate the effects of the exposure. To evaluate the window of opportunity for decontamination, the fielded skin decontaminant Reactive Skin Decontaminant Lotion (RSDL) was tested at different times in hairless guinea pigs percutaneously challenged with 4× LD50 VX in IPA. The results showed that RSDL decontamination at 15 min after exposure could not prevent progressive blood cholinesterase inhibition and therefore would still require additional treatment. A similar decontamination regimen with RSDL at 90 min showed that it still might effectively increase the time window of opportunity for treatment. In conclusion, the delay in absorption presents a window of opportunity for decontamination and treatment. The continuous release of VX from the skin presents a significant challenge for efficacious therapy, which should ideally consist of thorough decontamination and continuous treatment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent.
Waysbort, Daniel; McGarvey, David J; Creasy, William R; Morrissey, Kevin M; Hendrickson, David M; Durst, H Dupont
2009-01-30
A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Greentrade mark, has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO(4)(-2)) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t(1/2) < or = 4 min), 1:10 for HD (t(1/2) < 2 min with molybdate), and 1:10 for GD (t(1/2) < 2 min). The vapor concentrations of GD above the dry sorbent and the sorbent with decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD.
Leonardi, Natalia M; Tesán, Fiorella C; Zubillaga, Marcela B; Salgueiro, María J
2014-12-01
In accord with as-low-as-reasonably-achievable and good-manufacturing-practice concepts, the present study evaluated the efficiency of radioactivity decontamination of materials commonly used in laboratory surfaces and whether solvent spills on these materials affect the findings. Four materials were evaluated: stainless steel, a surface comprising one-third acrylic resin and two-thirds natural minerals, an epoxy cover, and vinyl-based multipurpose flooring. Radioactive material was eluted from a (99)Mo/(99m)Tc generator, and samples of the surfaces were control-contaminated with 37 MBq (100 μL) of this eluate. The same procedure was repeated with samples of surfaces previously treated with 4 solvents: methanol, methyl ethyl ketone, acetone, and ethanol. The wet radioactive contamination was allowed to dry and then was removed with cotton swabs soaked in soapy water. The effectiveness of decontamination was defined as the percentage of activity removed per cotton swab, and the efficacy of decontamination was defined as the total percentage of activity removed, which was obtained by summing the percentages of activity in all the swabs required to complete the decontamination. Decontamination using our protocol was most effective and most efficacious for stainless steel and multipurpose flooring. Moreover, treatment with common organic solvents seemed not to affect the decontamination of these surfaces. Decontamination of the other two materials was less efficient and was interfered with by the organic solvents; there was also great variability in the overall results obtained for these other two materials. In expanding our laboratory, it is possible for us to select those surface materials on which our decontamination protocol works best. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
Commercial Cleaning Products for Chemical Decontamination: A Scoping Study
2014-05-01
way to decontaminate food preparation surfaces in homes, restaurants, and processing plants that are tainted with ricin (http://www.acs.org/content...acs/en/pressroom/newsreleases/2011/march/hou sehold-bleach-can-decontaminate-food-prep-surfaces-in- ricin -bioterrorist- attack.html). Israel also
Skin decontamination cream for radiological contaminants: Formulation development and evaluation
Khan, Abdul Wadood; Kotta, Sabna; Rana, Sudha; Ansari, Shahid Husain; Sharma, Rakesh Kumar; Ali, Javed
2013-01-01
Background: Increased use of the radioactive materials in the field of research, medical, nuclear power plant, and industry has increased the risk of accidental exposure. Intentional use of the radioisotopes by terrorist organizations could cause exposure/contamination of a number of the population. In view of the accidental contamination, there is a need to develop self-usable decontamination formulations that could be used immediately after contamination is suspected. Materials and Methods: Present work was planned to optimize and develop self-usable radiation decontamination cream formulation. Various pharmaceutical parameters were characterized. 99mTc-sodium pertechnetate was used as radiocontaminant. Static counts were recorded before and after decontamination using single photon emission computed tomography. Results: Decontamination efficacy of the cream was found to be 42% ± 3% at 0-0.5 h after the exposure. Primary skin irritancy test was satisfactory as no erythema or edema was observed visually after 2 weeks of the formulation application. Conclusion: The decontamination studies proved the potential of EDTA to remove the radiological contaminants effectively. PMID:23799206
All-Weather Hydrogen Peroxide-Based Decontamination of CBRN Contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, George W.; Procell, Lawrence R.; Sorrick, David C.
2010-03-11
A hydrogen peroxide-based decontaminant, Decon Green, is efficacious for the decontamination of chemical agents VX (S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate), GD (Soman, pinacolyl methylphosphonofluoridate), and HD (mustard, bis(2-chloroethyl) sulfide); the biological agent anthrax (Bacillus anthracis); and radiological isotopes Cs-137 and Co-60; thus demonstrating the ability of this decontamination approach to ameliorate the aftermath of all three types of weapons of mass destruction (WMD). Reaction mechanisms afforded for the chemical agents are discussed as are rationales for the enhanced removal efficacy of recalcitrant 60Co on certain surfaces. Decontaminants of this nature can be deployed, and are effective, at very low temperatures (-32 °C),more » as shown for studies done with VX and HD simulants, without the need for external heat sources. Finally, the efficacy of a lower-logistics, dry decontaminant powder concentrate (utilizing the solid active-oxygen compounds peracetyl borate and Peroxydone) which can be reconstituted with water in the field prior to use, is presented.« less
Aerosol tests conducted at Aberdeen Proving Grounds MD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brockmann, John E.; Lucero, Daniel A.; Servantes, Brandon Lee
Test data are reported that demonstrate the deposition from a spray dispersion system (Illinois Tool Works inductively charging rotary atomization nozzle) for application of decontamination solution to various surfaces in the passenger cabin of a Boeing 737 aircraft. The decontamination solution (EnviroTru) was tagged with a known concentration of fluorescein permitting determination of both airborne decontaminant concentration and surface deposited decontaminant solution so that the effective deposition rates and surface coverage could be determined and correlated with the amount of material sprayed. Six aerosol dispersion tests were conducted. In each test, aluminum foil deposition coupons were set out throughout themore » passenger area and the aerosol was dispersed. The aerosol concentration was measured with filter samplers as well as with optical techniques Average aerosol deposition ranged from 3 to 15 grams of decontamination solution per square meter. Some disagreement was observed between various instruments utilizing different measurement principles. These results demonstrate a potentially effective method to disperse decontaminant to interior surfaces of a passenger aircraft.« less
NASA Astrophysics Data System (ADS)
Varady, Mark; Mantooth, Brent; Pearl, Thomas; Willis, Matthew
2014-03-01
A continuum model of reactive decontamination in absorbing polymeric thin film substrates exposed to the chemical warfare agent O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (known as VX) was developed to assess the performance of various decontaminants. Experiments were performed in conjunction with an inverse analysis method to obtain the necessary model parameters. The experiments involved contaminating a substrate with a fixed VX exposure, applying a decontaminant, followed by a time-resolved, liquid phase extraction of the absorbing substrate to measure the residual contaminant by chromatography. Decontamination model parameters were uniquely determined using the Levenberg-Marquardt nonlinear least squares fitting technique to best fit the experimental time evolution of extracted mass. The model was implemented numerically in both a 2D axisymmetric finite element program and a 1D finite difference code, and it was found that the more computationally efficient 1D implementation was sufficiently accurate. The resulting decontamination model provides an accurate quantification of contaminant concentration profile in the material, which is necessary to assess exposure hazards.
Decontamination Technologies, Task 3, Urban Remediation and Response Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heiser,J.; Sullivan, T.
In the aftermath of a Radiological Dispersal Device (RDD, also known as a dirty bomb) it will be necessary to remediate the site including building exteriors and interiors, equipment, pavement, vehicles, personal items etc. Remediation will remove or reduce radioactive contamination from the area using a combination of removing and disposing of many assets (including possible demolition of buildings), decontaminating and returning to service other assets, and fixing in place or leaving in place contamination that is deemed 'acceptable'. The later will require setting acceptable dose standards, which will require negotiation with all involved parties and a balance of riskmore » and cost to benefit. To accomplish the first two, disposal or decontamination, a combination of technologies will be deployed that can be loosely classified as: Decontamination; Equipment removal and size reduction; and Demolition. This report will deal only with the decontamination technologies that will be used to return assets to service or to reduce waste disposal. It will not discuss demolition, size reduction or removal technologies or equipment (e.g., backhoe mounted rams, rock splitter, paving breakers and chipping hammers, etc.). As defined by the DOE (1994), decontamination is removal of radiological contamination from the surfaces of facilities and equipment. Expertise in this field comes primarily from the operation and decommissioning of DOE and commercial nuclear facilities as well as a small amount of ongoing research and development closely related to RDD decontamination. Information related to decontamination of fields, buildings, and public spaces resulting from the Goiania and Chernobyl incidents were also reviewed and provide some meaningful insight into decontamination at major urban areas. In order to proceed with decontamination, the item being processed needs to have an intrinsic value that exceeds the cost of the cleaning and justifies the exposure of any workers during the decontamination process(es). In the case of an entire building, the value may be obvious; it's costly to replace the structure. For a smaller item such as a vehicle or painting, the cost versus benefit of decontamination needs to be evaluated. This will be determined on a case by case basis and again is beyond the scope of this report, although some thoughts on decontamination of unique, personal and high value items are given. But, this is clearly an area that starting discussions and negotiations early on will greatly benefit both the economics and timeliness of the clean up. In addition, high value assets might benefit from pre-event protection such as protective coatings or HEPA filtered rooms to prevent contaminated outside air from entering the room (e.g., an art museum).« less
The radio frequency (RF) heating process can be used to volumetrically heat and thus decontaminate uncontrolled landfills and hazardous substances from spills. After the landfills are heated, decontamination of the hazardous substances occurs due to thermal decomposition, vaporiz...
40 CFR 761.79 - Decontamination standards and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... disassembled electrical equipment), concrete, and non-porous surfaces covered with a porous surface, such as... person decontaminating porous surfaces other than concrete under paragraph (b)(4) of this section and non..., concrete, or non-porous surfaces. (1) The decontamination standard for water containing PCBs is: (i) Less...
40 CFR 761.79 - Decontamination standards and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... disassembled electrical equipment), concrete, and non-porous surfaces covered with a porous surface, such as... person decontaminating porous surfaces other than concrete under paragraph (b)(4) of this section and non..., concrete, or non-porous surfaces. (1) The decontamination standard for water containing PCBs is: (i) Less...
40 CFR 761.79 - Decontamination standards and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... disassembled electrical equipment), concrete, and non-porous surfaces covered with a porous surface, such as... person decontaminating porous surfaces other than concrete under paragraph (b)(4) of this section and non..., concrete, or non-porous surfaces. (1) The decontamination standard for water containing PCBs is: (i) Less...
40 CFR 761.79 - Decontamination standards and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... disassembled electrical equipment), concrete, and non-porous surfaces covered with a porous surface, such as... person decontaminating porous surfaces other than concrete under paragraph (b)(4) of this section and non..., concrete, or non-porous surfaces. (1) The decontamination standard for water containing PCBs is: (i) Less...
40 CFR 761.79 - Decontamination standards and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... disassembled electrical equipment), concrete, and non-porous surfaces covered with a porous surface, such as... person decontaminating porous surfaces other than concrete under paragraph (b)(4) of this section and non..., concrete, or non-porous surfaces. (1) The decontamination standard for water containing PCBs is: (i) Less...
Prior to re-entering a building following a chemical attack, decontamination and testing must be conducted to determine whether toxic agents have been eliminated or reduced to safe levels. Building contents must also be decontaminated and tested or destroyed. Recent incidents i...
USDA-ARS?s Scientific Manuscript database
Cross-contamination of fresh produce from persistent pathogen reservoirs is a known risk factor in processing environments. Industry requires a waterless, zero-contact, chemical-free method for removing pathogens from food-contact surfaces. Cold plasma was tested for its ability to remove biofilms f...
40 CFR 265.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2010 CFR
2010-07-01
... equipment, structures and soils. 265.114 Section 265.114 Protection of Environment ENVIRONMENTAL PROTECTION... decontamination of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soil must be properly disposed of, or decontaminated unless specified otherwise in...
40 CFR 265.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equipment, structures and soils. 265.114 Section 265.114 Protection of Environment ENVIRONMENTAL PROTECTION... decontamination of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soil must be properly disposed of, or decontaminated unless specified otherwise in...
40 CFR 265.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipment, structures and soils. 265.114 Section 265.114 Protection of Environment ENVIRONMENTAL PROTECTION... decontamination of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soil must be properly disposed of, or decontaminated unless specified otherwise in...
40 CFR 265.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2013 CFR
2013-07-01
... equipment, structures and soils. 265.114 Section 265.114 Protection of Environment ENVIRONMENTAL PROTECTION... decontamination of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soil must be properly disposed of, or decontaminated unless specified otherwise in...
40 CFR 265.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment, structures and soils. 265.114 Section 265.114 Protection of Environment ENVIRONMENTAL PROTECTION... decontamination of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soil must be properly disposed of, or decontaminated unless specified otherwise in...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-18
... and initiated a survey and decontamination of the Facility. Based on the Licensee's historical... decontamination activities, in accordance with their NRC-approved, operating radiation safety procedures, were... survey, the Licensee conducted decontamination activities, as necessary, in the areas of the Facility...
SURFACE DECONTAMINATION EFFICACY STUDIES FOR ...
Technical Brief This Technical Brief summarizes the findings from three studies in which the decontamination efficacy was determined for various liquid contaminants when applied to various surfaces that are contaminated with blister agents (vesicants).This may provide decision-makers with practical information on surface decontaminations options during a blister agent response.
Recent developments in chemical decontamination technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, C.J.
1995-03-01
Chemical decontamination of parts of reactor coolant systems is a mature technology, used routinely in many BWR plants, but less frequently in PWRs. This paper reviews recent developments in the technology - corrosion minimization, waste processing and full system decontamination, including the fuel. Earlier work was described in an extensive review published in 1990.
Precipitation-adsorption process for the decontamination of nuclear waste supernates
Lee, Lien-Mow; Kilpatrick, Lester L.
1984-01-01
High-level nuclear waste supernate is decontaminated of cesium by precipitation of the cesium and potassium with sodium tetraphenyl boron. Simultaneously, strontium-90 is removed from the waste supernate sorption of insoluble sodium titanate. The waste solution is then filtered to separate the solution decontaminated of cesium and strontium.
Precipitation-adsorption process for the decontamination of nuclear waste supernates
Lee, L.M.; Kilpatrick, L.L.
1982-05-19
High-level nuclear waste supernate is decontaminated of cesium by precipitation of the cesium and potassium with sodium tetraphenyl boron. Simultaneously, strontium-90 is removed from the waste supernate sorption of insoluble sodium titanate. The waste solution is then filtered to separate the solution decontaminated of cesium and strontium.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the validation study and subsequent use during decontamination. 761.386 Section 761.386 Protection of... (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Comparison Study for... experimental conditions for the validation study and subsequent use during decontamination. The following...
Code of Federal Regulations, 2010 CFR
2010-07-01
... the validation study and subsequent use during decontamination. 761.386 Section 761.386 Protection of... (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Comparison Study for... experimental conditions for the validation study and subsequent use during decontamination. The following...
Code of Federal Regulations, 2014 CFR
2014-07-01
... the validation study and subsequent use during decontamination. 761.386 Section 761.386 Protection of... experimental conditions for the validation study and subsequent use during decontamination. The following experimental conditions apply for any solvent: (a) Temperature and pressure. Conduct the validation study and...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the validation study and subsequent use during decontamination. 761.386 Section 761.386 Protection of... experimental conditions for the validation study and subsequent use during decontamination. The following experimental conditions apply for any solvent: (a) Temperature and pressure. Conduct the validation study and...
Code of Federal Regulations, 2013 CFR
2013-07-01
... the validation study and subsequent use during decontamination. 761.386 Section 761.386 Protection of... experimental conditions for the validation study and subsequent use during decontamination. The following experimental conditions apply for any solvent: (a) Temperature and pressure. Conduct the validation study and...
The pharmacological activity of medical herbs after microbiological decontamination by irradiation
NASA Astrophysics Data System (ADS)
Owczarczyk, H. B.; Migdał, W.; K ȩdzia, B.
2000-03-01
In the Institute of Nuclear Chemistry and Technology research on microbiological decontamination of medicinal herbs by irradiation has been carried out since 1996. It was shown that using ionizing radiation (a dose of 10 kGy) can obtain satisfactory results of microbiological decontamination of these products. The content of essential biologically active substances such as essential oils, flavonoids, glycosides, anthocyans, antra-compounds, poliphenoloacids, triterpene saponins, oleanosides and plants mucus did not change significantly after irradiation. Pharmacological activity of medicinal herbs has been found satisfactory after microbiological decontamination by irradiation.
Skin decontamination: principles and perspectives.
Chan, Heidi P; Zhai, Hongbo; Hui, Xiaoying; Maibach, Howard I
2013-11-01
Skin decontamination is the primary intervention needed in chemical, biological and radiological exposures, involving immediate removal of the contaminant from the skin performed in the most efficient way. The most readily available decontamination system on a practical basis is washing with soap and water or water only. Timely use of flushing with copious amounts of water may physically remove the contaminant. However, this traditional method may not be completely effective, and contaminants left on the skin after traditional washing procedures can have toxic consequences. This article focuses on the principles and practices of skin decontamination.
Koenig, Kristi L; Boatright, Connie J; Hancock, John A; Denny, Frank J; Teeter, David S; Kahn, Christopher A; Schultz, Carl H
2008-01-01
Since the US terrorist attacks of September 11, 2001, concern regarding use of chemical, biological, or radiological weapons is heightened. Many victims of such an attack would present directly to health care facilities without first undergoing field decontamination. This article reviews basic tenets and recommendations for health care facility-based decontamination, including regulatory concerns, types of contaminants, comprehensive decontamination procedures (including crowd control, triage, removal of contaminated garments, cleaning of body contaminants, and management of contaminated materials and equipment), and a discussion of methods to achieve preparedness.
Microbiological Burden on the Surfaces of Explorer XXXIII Spacecraft1
Powers, Edmund M.
1967-01-01
The Explorer XXXIII Spacecraft (Anchored Interplanetary Monitoring Platform, or AIMP) was decontaminated to prevent gross contamination of the moon with terrestrial microorganisms. Assay of the total spacecraft surface before and after decontamination showed that the decontamination procedure reduced the viable microbiological burden from 1.40 × 106 to 3.60 × 104. However, assembly of parts which were not decontaminated for engineering reasons or were not assembled under cleanroom conditions increased the viable microbial burden at the time of launch to 2.62 × 105. Images Fig. 2 PMID:6053173
Improvement in ultraviolet based decontamination rate using meta-materials
NASA Astrophysics Data System (ADS)
Enaki, Nicolae A.; Bazgan, Sergiu; Ciobanu, Nellu; Turcan, Marina; Paslari, Tatiana; Ristoscu, Carmen; Vaseashta, Ashok; Mihailescu, Ion N.
2017-09-01
We propose a method of decontamination using photon-crystals consisting of microspheres and fiber optics structures with various geometries. The efficient decontamination using the surface of the evanescent zone of meta-materials opens a new perspective in the decontamination procedures. We propose different topological structures of meta-materials to increase the contact surface of UV radiation with contaminated liquid. Recent observation of the trapping of dielectric particles along the fibers help us propose a new perspective on the new possibilities to trap the viruses, bacteria and other microorganisms from liquids, in this special zone, where the effective UV coherent Raman decontamination becomes possible. The nonlinear theory of the excitation of vibration modes of bio-molecule of viruses and bacteria is revised, taking into consideration the bimodal coherent states in coherent Raman excitation of biomolecules.
Hairy skin exposure to VX in vitro: effectiveness of delayed decontamination.
Rolland, P; Bolzinger, M-A; Cruz, C; Josse, D; Briançon, S
2013-02-01
The chemical warfare agents such as VX represent a threat for both military and civilians, which involves an immediate need of effective decontamination systems. Since human scalp is usually unprotected compared to other body regions covered with clothes, it could be a preferential site of exposure in case of terrorist acts. The purpose of this study was to determine if skin decontamination could be efficient when performed more than 1h after exposure. In addition, the impact of hairs in skin contamination was investigated. By using in vitro skin models, we demonstrated that about 75% of the applied quantity of VX was recovered on the skin surface 2h after skin exposition, which means that it is worth decontaminating even if contamination occurred 2h before. The stratum corneum reservoir for VX was quickly established and persistent. In addition, the presence of hairs modified the percutaneous penetration of the nerve agent by binding of VX to hairs. Hair shaft has thus to be taken into account in the decontamination process. Reactive Skin Decontamination Lotion (RSDL) and Fuller's Earth (FE) were active in the skin decontamination 45min post-exposure, but RSDL was more efficient in reducing the amount of VX either in the skin or in the hair. Copyright © 2012 Elsevier Ltd. All rights reserved.
Comparison of four different fuller's earth formulations in skin decontamination.
Roul, Annick; Le, Cong-Anh-Khanh; Gustin, Marie-Paule; Clavaud, Emmanuel; Verrier, Bernard; Pirot, Fabrice; Falson, Françoise
2017-12-01
Industrial accidents, wars and terrorist threats are potential sources of skin contamination by highly toxic chemical warfare agents and manufacturing compounds. We have compared the time-dependent adsorption capacity and decontamination efficiency of fuller's earth (FE) for four different formulations for the molecular tracer, 4-cyanophenol (4-CP), in vitro and ex vivo using water decontamination as standard. The adsorption capacity of FE was assessed in vitro for 4-CP aqueous solutions whereas decontamination efficiency was investigated ex vivo by tracking porcine skin 4-CP content using attenuated total reflectance Fourier transform infrared spectroscopy. Decontamination was performed on short time, exposed porcine skin to 4-CP by application of FE: (1) as free powder; (2) loaded on adhesive tape; (3) on powdered glove; or (4) in suspension. Removal rate of 4-CP from aqueous solutions correlates with the amount of FE and its contact time. Decontamination efficiency estimated by the percentage of 4-CP recovery from contaminated porcine skin, achieved 54% with water, ranged between ~60 and 70% with dry FE and reached ~90% with FE suspension. Successful decontamination of the FE suspension, enabling a dramatic reduction of skin contamination after a brief exposure scenario, appears to be rapid, reliable and should be formulated in a new device ready to use for self-application. Copyright © 2017 John Wiley & Sons, Ltd.
Kauppinen, Ari; Ikonen, Jenni; Pursiainen, Anna; Pitkänen, Tarja; Miettinen, Ilkka T
2012-09-01
A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.
Novel Prevention Strategies for Bacterial Infections in Cirrhosis
Yan, Kathleen; Garcia-Tsao, Guadalupe
2016-01-01
Introduction Bacterial infections are a serious complication of cirrhosis, as they can lead to decompensation, multiple organ failure, and/or death. Preventing infections is therefore very relevant. Because gut bacterial translocation is their main pathogenic mechanism, prevention of infections is mostly based on the use of orally administered poorly absorbed antibiotics such as norfloxacin (selective intestinal decontamination). However, antibiotic prophylaxis leads to antibiotic resistance, limiting therapy and increasing morbidity and mortality. Prevention of bacterial infections in cirrhosis should therefore move away from antibiotics. Areas Covered This review focuses on various potentially novel methods to prevent infections in cirrhosis focusing on non-antibiotic strategies. The use of probiotics, nonselective intestinal decontamination with rifaximin, prokinetics and beta-blockers or fecal microbiota transplant as means of targeting altered gut microbiota, bile acids and FXR agonists are all potential alternatives to selective intestinal decontamination. Prokinetics and beta-blockers can improve intestinal motility, while bile acids and FXR agonists help by improving the intestinal barrier. Finally, granulocyte colony stimulating factor (G-CSF) and statins are emerging therapeutic strategies that may improve immune dysfunction in cirrhosis. Expert Opinion Evidence for these strategies has been restricted to animal studies and proof-of concept studies but we expect this to change in coming years. PMID:26799197
Methods of preventing bacterial sepsis and wound complications after liver transplantation.
Gurusamy, Kurinchi Selvan; Nagendran, Myura; Davidson, Brian R
2014-03-05
Bacterial sepsis and wound complications after liver transplantation increase mortality, morbidity, or hospital stay and are likely to increase overall transplant costs. All liver transplantation patients receive antibiotic prophylaxis. This is an update of our 2008 Cochrane systematic review on the same topic in which we identified seven randomised clinical trials. To assess the benefits and harms of different methods aimed at preventing bacterial sepsis and wound complications in people undergoing liver transplantation. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and Science Citation Index Expanded to February 2013. We included only randomised clinical trials irrespective of language or publication status. We excluded quasi-randomised and other observational studies for assessment of benefits, but not for harms. Two review authors collected the data independently. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI) using fixed-effect and the random-effects models based on available-case analysis. We identified only seven trials for inclusion, including 614 participants. Only one trial was of low risk of bias risk. Overall, the quality of evidence was very low. There were five comparisons in the seven trials: selective bowel decontamination versus inactive control; selective bowel decontamination versus prebiotics with probiotics; selective bowel decontamination versus prebiotics; prebiotics with probiotics versus prebiotics; and granulocyte-colony stimulating factor (G-CSF) versus control. Four trials compared selective bowel decontamination versus placebo or no treatment. In one trial, participants were randomised to selective bowel decontamination, active lactobacillus with fibres (probiotic with prebiotic), or to inactivated lactobacillus with fibres (prebiotic). In one trial, active lactobacillus with fibres (probiotic with prebiotic) was compared with inactive lactobacillus with fibres (prebiotic). In the remaining trial, different doses of G-CSF and placebo were compared. There was no trial comparing different antibiotic prophylactic regimens in people undergoing liver transplantation. Most trials included adults undergoing elective liver transplantation. There was no significant difference in proportion of people who died or required retransplantation between the intervention and control groups in any of the five comparison groups. MORTALITY There were no differences between 190 participants (three trials); 5/87 (adjusted proportion: 6.2%) in selective bowel decontamination group versus 7/103 (6.8%) in inactive control group; RR 0.91 (95% CI 0.31 to 2.72); 63 participants (one trial); 0/32 (0%) in selective bowel decontamination group versus 0/31 (0%) in prebiotics with probiotics group; RR - not estimable; 64 participants (one trial); 0/32 (0%) in selective bowel decontamination group versus 0/32 (0%) in prebiotics group; RR - not estimable; 129 participants (two trials); 0/64 (0%) in prebiotics with probiotics group versus 0/65 (0%) in prebiotics group; RR - not estimable; and 194 participants (one trial); 22/124 (17.7%) in G-CSF group versus 10/70 (14.3%) in placebo group; RR 1.24 (95% 0.62 to 2.47). RETRANSPLANTATION There were no differences between 132 participants (two trials); 4/58 (adjusted proportion: 6.9%) in selective bowel decontamination group versus 6/74 (8.1%) in inactive control group; RR 0.85 (95% CI 0.26 to 2.85); 63 participants (one trial); 1/32 (3.1%) in selective bowel decontamination group versus 0/31 (0%) in prebiotics with probiotics group; RR 2.91 (0.12 to 68.81); 64 participants (one trial); 1/32 (3.1%) in selective bowel decontamination group versus 0/32 (0%) in prebiotics group; RR 3.00 (95% CI 0.13 to 71.00); 129 participants (two trials); 0/64 (0%) in prebiotics with probiotics group versus 1/65 (1.5%) in prebiotics group; RR 0.33 (95% CI 0.01 to 7.9); and 194 participants (one trial); 10/124 (7.1%) in G-CSF group versus 5/70 (7.1%) in placebo group; RR 1.13 (95% CI 0.4 to 3.17).There was no significant difference in the graft rejections, intensive therapy unit stay, or hospital stay between the intervention and control groups in any of the comparisons. Overall, 193/611 participants (31.6%) developed infective complications. The proportion of people who developed infective complications and the number of infective complication episodes were significantly higher in the selective bowel decontamination group than in the prebiotics with probiotics group (1 study; 63 participants; 15/32 (46.9%) in selective bowel decontamination group versus 4/31 (12.9%) in prebiotics with probiotics group; RR 3.63; 95% CI 1.36 to 9.74 and 23/32 participants (0.72 infective complications per participant) in selective bowel decontamination group versus 4/31 participants (0.13 infective complications per participant) in prebiotics with probiotics group; rate ratio 5.58; 95% CI 1.94 to 16.09). There was no significant difference between the proportion of participants who developed infection and the number of infection episodes between the intervention group and control group in any of the other comparisons.No trials reported quality of life and overall serious adverse events. Currently, there is no clear evidence for any intervention offering significant benefits in the reduction of bacterial infections and wound complications in liver transplantation. Selective bowel decontamination may even increase the rate of infections compared with prebiotics with probiotics. The confidence intervals were wide and further randomised clinical trials of low risk of bias are necessary.
Skin decontamination efficacy of potassium ketoxime on rabbits exposed to sulfur mustard.
Sun, Jing-Hai; Sun, Pei-Pei; Zheng, Wei; Han, Song; Ying, Ying; Liu, Hong-Yan; Zhang, Cheng; Zhao, Bao-Quan; Zuo, Guo-Min; Lu, Hong; Zhong, Yu-Xu
2015-03-01
The chemical weapon sulfur mustard (SM) is a blister agent, and currently, there is no effective antidote. To evaluate the decontamination efficacy of potassium ketoxime against SM and preliminarily elucidate its decontamination mechanism. Potassium ketoxime reacted with SM, and SM residues were tested at different time intervals by T-135 colorimetry after the reaction. Rabbit skin was topically exposed to 2 mg/cm(2) SM, treated with potassium ketoxime 1 min later, and observed after 6, 12, and 24 h. Gas chromatography-mass spectroscopy was employed to screen and identify the main products of potassium ketoxime decontamination of SM. Potassium ketoxime had a great effect against SM contamination. With a mass ratio of decontaminant: SM of 50:1, decontamination rates against SM were 87.5% after 30 s, 95.9% after 1 min, and 99.0% after 5 min. Fifteen minutes after exposure to SM, the untreated group showed clear erythema lesions, whereas the experimental group showed no clear erythema lesions within 6 h. After 12 and 24 h, the areas of damaged skin in the experimental group were 0.038 and 0.125 cm(2), respectively, compared with 2.21 and 2.65 cm(2) in the control group. Histopathological analysis revealed that treatment with potassium ketoxime also reduced inflammation-induced damage. The results of this study indicate that potassium ketoxime reacted rapidly and completely with SM, and thus, it was found to be a suitable and effective skin decontaminant against SM. The decontamination reaction mechanism is mainly related to nucleophilic substitution.
Southworth, P M
2014-11-01
Reusable surgical instruments provide a potential route for the transmission of pathogenic agents between patients in healthcare facilities. As such, the decontamination process between uses is a vital component in the prevention of healthcare-associated infections. This article reviews reported outbreaks and incidents associated with inappropriate, inadequate, or unsuccessful decontamination of surgical instruments, indicating potential pitfalls of decontamination practices worldwide. To the author's knowledge, this is the first review of surgical instrument decontamination failures. Databases of medical literature, Medline and Embase, were searched systematically. Articles detailing incidents associated with unsuccessful decontamination of surgical instruments were identified. Twenty-one articles were identified reporting incidents associated with failures in decontamination. A large proportion of incidents involved the attempted disinfection, rather than sterilization, of surgical instruments (43% of articles), counter to a number of national guidelines. Instruments used in eye surgery were most frequently reported to be associated with decontamination failures (29% of articles). Of the few articles detailing potential or confirmed pathogenic transmission, Pseudomonas aeruginosa and Mycobacterium spp. were most represented. One incident of possible variant Creutzfeldt-Jakob disease transmission was also identified. Limitations of analysing only published incidents mean that the likelihood of under-reporting (including reluctance to publish failure) must be considered. Despite these limitations, the small number of articles identified suggests a relatively low risk of cross-infection through reusable surgical instruments when cleaning/sterilization procedures are adhered to. The diverse nature of reported incidents also suggests that failures are not systemic. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Poornejad, Nafiseh; Nielsen, Jeffery J; Morris, Ryan J; Gassman, Jason R; Reynolds, Paul R; Roeder, Beverly L; Cook, Alonzo D
2016-03-01
Engineering whole organs from porcine decellularized extracellular matrix and human cells may lead to a plentiful source of implantable organs. Decontaminating the porcine decellularized extracellular matrix scaffolds is an essential step prior to introducing human cells. However, decontamination of whole porcine kidneys is a major challenge because the decontamination agent or irradiation needs to diffuse deep into the structure to eliminate all microbial contamination while minimizing damage to the structure and composition of the decellularized extracellular matrix. In this study, we compared four decontamination treatments that could be applicable to whole porcine kidneys: 70% ethanol, 0.2% peracetic acid in 1 M NaCl, 0.2% peracetic acid in 4% ethanol, and gamma (γ)-irradiation. Porcine kidneys were decellularized by perfusion of 0.5% (w/v) aqueous solution of sodium dodecyl sulfate and the four decontamination treatments were optimized using segments (n = 60) of renal tissue to ensure a consistent comparison. Although all four methods were successful in decontamination, γ-irradiation was very damaging to collagen fibers and glycosaminoglycans, leading to less proliferation of human renal cortical tubular epithelium cells within the porcine decellularized extracellular matrix. The effectiveness of the other three optimized solution treatments were then all confirmed using whole decellularized porcine kidneys (n = 3). An aqueous solution of 0.2% peracetic acid in 1 M NaCl was determined to be the best method for decontamination of porcine decellularized extracellular matrix. © The Author(s) 2015.
Evaluation of Microwave Steam Bags for the Decontamination of Filtering Facepiece Respirators
Fisher, Edward M.; Williams, Jessica L.; Shaffer, Ronald E.
2011-01-01
Reusing filtering facepiece respirators (FFRs) has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers' instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9% effective for inactivating MS2 on FFRs; however, more research is required to determine the effectiveness against respiratory pathogens. PMID:21525995
NASA Astrophysics Data System (ADS)
Shtripling, L. O.; Kholkin, E. G.
2018-01-01
The article presents the procedure for determining the basic geometrical setting parameters for the oil-contaminated soils decontamination with reagent encapsulation method. An installation is considered for the operational elimination of the emergency consequences accompanied with oil spills, and the installation is adapted to winter conditions. In the installations exothermic process thermal energy of chemical neutralization of oil-contaminated soils released during the decontamination is used to thaw frozen subsequent portions of oil-contaminated soil. Installation for oil-contaminated soil decontamination as compared with other units has an important advantage, and it is, if necessary (e.g., in winter) in using the heat energy released at each decontamination process stage of oil-contaminated soil, in normal conditions the heat is dispersed into the environment. In addition, the short-term forced carbon dioxide delivery at the decontamination process final stage to a high concentration directly into the installation allows replacing the long process of microcapsule shells formation and hardening that occur in natural conditions in the open air.
Novel Laser Ablation Technology for Surface Decontamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Chung H.
2004-06-01
Laser ablation for surface cleaning has been pursued for the removal of paint on airplanes. It has also been pursued for the cleaning of semiconductor surfaces. However, all these approaches have been pursued by laser ablation in air. For highly contaminated surface, laser ablation in air can easily cause secondary contamination. Thus it is not suitable to apply to achieve surface decontamination for DOE facilities since many of these facilities have radioactive contaminants on the surface. Any secondary contamination will be a grave concern. The objective of this project is to develop a novel technology for laser ablation in liquidmore » for surface decontamination. It aims to achieve more efficient surface decontamination without secondary contamination and to evaluate the economic feasibility for large scale surface decontamination with laser ablation in liquid. When laser ablation is pursued in the solution, all the desorbed contaminants will be confined in liquid. The contaminants can be precipitated and subsequently contained in a small volume for disposal. It can reduce the risk of the decontamination workers. It can also reduce the volume of contaminants dramatically.« less
Study on hot melt pressure sensitive coil material for removing surface nuclear pollution dust
NASA Astrophysics Data System (ADS)
Wang, Jing; Li, Jiao; Wang, Jianhui; Zheng, Li; Li, Jian; Lv, Linmei
2018-02-01
A new method for removing surface nuclear pollution by using hot melt pressure sensitive membrane was presented. The hot melt pressure sensitive membrane was designed and prepared by screening hot melt pressure sensitive adhesive and substrate. The simulated decontamination test of the hot melt pressure sensitive membrane was performed by using 100 mesh and 20 mesh standard sieve dust for simulation of nuclear explosion fall ash and radioactive contaminated particles, respectively. It was found that the single decontamination rate of simulated fall ash and contaminated particles were both above 80% under pressure conditions of 25kPa or more at 140°C. And the maximum single decontamination rate was 92.5%. The influence of heating temperature and pressure on the decontamination rate of the membrane was investigated at the same time. The results showed that higher heating temperature could increase the decontamination rate by increasing the viscosity of the adhesive. When the adhesive amount of the adhesive layer reached saturation, a higher pressure could increase the single decontamination rate also.
Enhancing activated-peroxide formulations for porous materials: Test methods and results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krauter, Paula; Tucker, Mark D.; Tezak, Matthew S.
2012-12-01
During an urban wide-area incident involving the release of a biological warfare agent, the recovery/restoration effort will require extensive resources and will tax the current capabilities of the government and private contractors. In fact, resources may be so limited that decontamination by facility owners/occupants may become necessary and a simple decontamination process and material should be available for this use. One potential process for use by facility owners/occupants would be a liquid sporicidal decontaminant, such as pHamended bleach or activated-peroxide, and simple application devices. While pH-amended bleach is currently the recommended low-tech decontamination solution, a less corrosive and toxic decontaminantmore » is desirable. The objective of this project is to provide an operational assessment of an alternative to chlorine bleach for low-tech decontamination applications activated hydrogen peroxide. This report provides the methods and results for activatedperoxide evaluation experiments. The results suggest that the efficacy of an activated-peroxide decontaminant is similar to pH-amended bleach on many common materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoyt, K.R.; Pavelek, M.D. II
1987-01-01
Following the accident at Three Mile Island Unit 2 (TMI-2) substantial areas in the auxiliary and fuel-handling buildings were contaminated. Overflowing sumps backed up floor drains and contaminated a substantial portion of the 282-ft elevation floor. In addition, contamination was spread into the overheads when the nitrogen purge system, which had become internally contaminated, was relieved of overpressure. Operating experience with the Kelly Decontamination System has been exceptional. The system has been defined as a tool of the trade for labor personnel to operate as part of their duties. A detailed training program was provided by the Kelly Division ofmore » Container Products Corporation for the engineers who then trained labor personnel in the operation of the equipment. There were very few problems with personnel on the equipment for routine decontamination operations. The Kelly Decontamination System has proven to be a dose and cost-effective alternative to hands-on decontamination techniques at TMI-2 and should have wide application for large-scale decontamination operations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dill, G.S.; Leonard, R.D.
1991-04-01
A study was performed to determine the effect of three commonly used field decontaminants, DS2, super tropical bleach (STB), and the M270 Decontaminating Kit, Individual (DKIE), on the Resuscitation Device, Chemical, Individual (RDIC). The RDIC system was analyzed to determine which components were accessible to chemical agents and could be degraded by them. The chemical agent susceptibility of the silicone rubber components is the weakest point in the RDIC system. The lack of accessibility of key components to the wetted DKIE wipes and the deterioration of key components by DS2 eliminates these two methods as possible decontaminant methods. STB hadmore » no noticeable effects on the RDIC and is recommended as the best field decontamination method.« less
Jacquet, Pauline; Daudé, David; Bzdrenga, Janek; Masson, Patrick; Elias, Mikael; Chabrière, Eric
2016-05-01
Organophosphorus chemicals are highly toxic molecules mainly used as pesticides. Some of them are banned warfare nerve agents. These compounds are covalent inhibitors of acetylcholinesterase, a key enzyme in central and peripheral nervous systems. Numerous approaches, including chemical, physical, and biological decontamination, have been considered for developing decontamination methods against organophosphates (OPs). This work is an overview of both validated and emerging strategies for the protection against OP pollution with special attention to the use of decontaminating enzymes. Considerable efforts have been dedicated during the past decades to the development of efficient OP degrading biocatalysts. Among these, the promising biocatalyst SsoPox isolated from the archaeon Sulfolobus solfataricus is emphasized in the light of recently published results. This hyperthermostable enzyme appears to be particularly attractive for external decontamination purposes with regard to both its catalytic and stability properties.
An improved method for emergent decontamination of ocular and dermal hydrofluoric acid splashes.
Soderberg, Kjell; Kuusinen, Petri; Mathieu, Laurence; Hall, Alan H
2004-08-01
Accidental hydrofluoric acid (HF) splashes often occur in industrial settings. HF easily penetrates into tissues by initial acid action allowing fluoride ions to penetrate deeply, chelating calcium and magnesium. Resultant hypocalcemia and hypomagnesemia can be fatal. This report describes the utilization of Hexafluorine--a hypertonic, amphoteric, chelating decontamination solution--in workplaces where water decontamination followed by calcium gluconate inunction failed to prevent HF burns and systemic toxicity. Between 1998 and 1999, 16 cases of ocular and dermal HF splashes with either 70% HF or 6% HF/15% nitric acid (HNO3) were decontaminated with Hexafluorine at the worksite. HF burns did not develop and medical treatment other than initial decontamination was not reQuired in 12/16 (75%). In 7/16 (44%) cases, lost work time corresponded to duration of hospital observation (mean < 1 d).
Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Chojecka, Agnieszka; Zmuda-Baranowska, Magdalena; Kanclerski, Krzysztof
2012-01-01
Effective decontamination of instruments is a key element of infection control and the provision of high quality in dental care. The aim of the study was to evaluate the efficiency of decontamination procedures including cleaning, disinfection and sterilization of re-usable instruments in dental practices in Poland. The efficiency of disinfection and sterilization processes have been evaluated on the results of the questionnaires. The following information were taken into account: setting where disinfection and sterilization had been performed, preparation of dental equipment for sterilization (disinfection, washing and cleaning, packaging), the types of autoclaves and used types of sterilization cycles, routine monitoring and documentation of sterilization processes, treatment of handpieces and the frequency of surface decontamination. Data were collected from 43 dental practices (35 dental offices and 8 clinics). Disinfection and cleaning processes were performed manually in 63% of dental offices and ultrasonic baths were used in 53% of settings. Washer disinfectors were used in 23% of dental practices: in every researched clinic and in a few dental offices. All sterilization processes were performed in steam autoclaves, mainly in small steam sterilizers (81%). Dental handpieces were sterilized in 72% of practices, but only 33% of them performed sterilization in recommended cycle B. Sterilization processes were monitored with chemical indicators in 33% of practices. Biological monitoring of the processes was carried out at different intervals. Incorrect documentation of instruments and surfaces decontamination was recorded in several settings. There is still a need for improvement of decontamination processes in dental practice in Poland. Areas for improvement include: replacement of manual cleaning and disinfection processes with automatic processes, sterilization of dental handpieces after each patient, monitoring of a sterilization process with chemical and biological indicators. Reported incorrect procedures in decontamination of medical devices performed by questioned dentists and lack or inadequate response to asked questions indicate the lack of adequate knowledge about decontamination. Personnel who performs decontamination processes should be continuously trained.
Skin decontamination with mineral cationic carrier against sarin determined in vivo.
Vucemilović, Ante; Hadzija, Mirko; Jukić, Ivan
2009-06-01
Our Institute's nuclear, biological, and chemical defense research team continuously investigates and develops preparations for skin decontamination against nerve agents. In this in vivo study, we evaluated skin decontamination efficacy against sarin by a synthetic preparation called Mineral Cationic Carrier (MCC) with known ion exchange, absorption efficacy and bioactive potential. Mice were treated with increasing doses of sarin applied on their skin, and MCC was administered immediately after contamination. The results showed that decontamination with MCC could achieve therapeutic efficacy corresponding to 3 x LD(50) of percutaneous sarin and call for further research.
NATIONAL RESPONSE TEAM TECHNICAL ASSISTANCE ...
This document provides technical information on a wide range of activities to aid in response to intentional release of anthrax in urban environments. It includes initial actions when a potential release is discovered, health and safety issues for responders, sampling and analysis methods, decontamination technologies, decontamination waste disposal, and communication with public. This document provides technical information on a wide range of activities to aid in response to intentional release of anthrax in urban environments. It includes initial actions when a potential release is discovered, health and safety issues for responders, sampling and analysis methods, decontamination technologies, decontamination waste disposal, and communication with public.
Health investigations of depleted-uranium clean-up workers.
Milacic, Snezana
2008-01-01
The soil contaminated by depleted uranium (238U) ammunition during the NATO bombing of Serbia and Montenegro was cleaned-up for four months in 2002. A team of 11 clean-up workers (expert members) were medically examined three times: before decontamination as a preliminary medical check-up, immediately after decontamination, and four years after cleaning up contaminated ground. This short report presents investigations and health risk assessments of clean-up workers in radioactive decontamination operations and an assessment of the environmental health perspectives for citizens living in surrounding areas. The method of initial health disorders was used, analyzing the most sensitive biological materials, such as blood cells or chromosome damage, DNA strand breaks, radio-toxicological examination of urine. The total number of blood cells did not change, but variations of the relative number (percentage) of cells in the leukocyte formula were observed. The total number of DNA alterations was higher immediately after decontamination than before decontamination. Four years after decontamination the number of DNA alterations had decreased. However, the number of damaged cells (lymphocytes containing chromosome lesions) was higher in both medical examinations, immediately after and four years after decontamination. Disease or tumours due to 238U did not develop in the group of depleted uranium clean-up workers during the investigation period of four years. Further monitoring of haematological and chromosomal effects and the health condition of workers is necessary.
Report of decontamination at Tominari Elementary School.
Katsumi, S
2016-12-01
On 19 April 2011, the Ministry of Education, Culture, Sports, Science, and Technology designated 13 elementary schools, including Tominari Elementary School in Date city, as high-dose schools that needed to restrict outdoor activities due to the effects of the accident at Fukushima Daiichi nuclear power plant. Approximately 1 week later, the municipal government took action to remove the topsoil from the school grounds, and the prohibition of outdoor activities at Tominari Elementary School was lifted. The school staff continued to work on decontaminating the surrounding areas using high-pressure washers and brushes. There were certain positive outcomes, but a more effective decontamination method was required. In July 2011, the municipal government started an environmental remediation project, both inside and outside the school buildings, with researchers and decontamination workers at Tominari Elementary School, involving members of the Parent-Teacher Association (PTA), local communities, and volunteers using various effective and specialised forms of decontamination. As a result, Tominari Elementary School was able to recommence swimming lessons at the end of the first semester, which had been thought to be impossible. This article will provide information about the importance of 'dialogue' for decontamination, how engagement of the experts gave members of the PTA and the local community a feeling of 'security and safety', and how the decontamination work was an ever-expanding collaborative work of a large number of people.
Ardizzoni, E; Mulders, W; Sanchez-Padilla, E; Varaine, F; de Jong, B C; Rigouts, L
2014-08-01
Long transportation times of samples to culture laboratories can lead to higher contamination rates and significant loss of viability, resulting in lower culture positivity rates. Thin-layer agar (TLA) is a sensitive culture method for the isolation of Mycobacterium tuberculosis that has been optimised with N-acetyl-L-cysteine-sodium hydroxide (NALC-NaOH) decontaminated samples. The combination of the TLA culture method and other decontamination procedures has not been extensively validated. Among 390 smear-positive samples, we compared the culture positivity of samples decontaminated using the Petroff method vs. NALC-NaOH neutralised with phosphate buffer (PBS), applied to samples preserved with cetylpyridinium chloride (CPC) or CPC-free, and then of CPC-preserved samples decontaminated with NALC-NaOH neutralised using Difco neutralising buffer. The sediments were inoculated on TLA, and then on MGIT 960 or Löwenstein-Jensen (LJ) as gold standards. Decontamination with NALC-NaOH yielded higher culture positivity in TLA than in the Petroff method, which was further enhanced by neutralising CPC with the Difco buffer. Surprisingly, culture positivity on LJ also increased after using Difco buffer, suggesting that CPC may not be completely neutralised in egg-based medium. After transportation in CPC, decontamination using NALC-NaOH followed by neutralisation using Difco buffer resulted in the best recovery rates for samples inoculated on TLA and on LJ.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of biological agents on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some biological agents, but data gaps remain. Data on bacterial spore persistence on common water infrastructure materials such as iron and cement-mortar lined iron show that spores can be persistent for weeks after contamination. Decontamination data show that common disinfectants such as free chlorine have limited effectiveness. Decontamination results with germinant and alternate disinfectants such as chlorine dioxide are more promising. Persistence and decontamination data were collected on vegetative bacteria, such as coliforms, Legionella and Salmonella. Vegetative bacteria are less persistent than spores and more susceptible to disinfection, but the surfaces and water quality conditions in many studies were only marginally related to drinking water systems. However, results of real-world case studies on accidental contamination of water systems with E. coli and Salmonella contamination show that flushing and chlorination can help return a water system to service. Some viral persistence data were found, but decontamination data were lacking. Future research suggestions focus on expanding the available biological persistence data to other common infrastructure materials. Further exploration of non-traditional drinking water disinfectants is recommended for future studies. Published by Elsevier Ltd.
Chemical Decontaminant Testing
2014-10-20
make certain that the amine group on the VX is entirely in the freebase form needed for complete extraction into the chloroform. (3) When other...information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for information on ...material effects of decontaminants on fielded military equipment (material effects are defined as hardness). Mechanisms of decontaminating equipment
Enzymatic Decontamination of Environmental Organophosphorus Compounds
2006-12-04
ABSTRACT (Maximum 200 words) The abstract is below since many authors do not follow the 200 word limit 14. SUBJECT TERMS organophosphorus compounds ...5404 Enzymatic decontamination of environmental organophosphorus compounds REPORT DOCUMENTATION PAGE 18. SECURITY CLASSIFICATION ON THIS PAGE...239-18 298-102 15. NUMBER OF PAGES 20. LIMITATION OF ABSTRACT UL - 4-Dec-2006 Enzymatic decontamination of environmental organophosphorus compounds
Evaluation of Hydrogel Technologies for the Decontamination ...
Report This current research effort was developed to evaluate intermediate level (between bench-scale and large-scale or wide-area implementation) decontamination procedures, materials, technologies, and techniques used to remove radioactive material from different surfaces. In the event of such an incident, application of this technology would primarily be intended for decontamination of high-value buildings, important infrastructure, and landmarks.
Comparison of impact of two decontamination solutions on the viability of the cells in human amnion.
Smeringaiova, Ingrida; Trosan, Peter; Mrstinova, Miluse Berka; Matecha, Jan; Burkert, Jan; Bednar, Jan; Jirsova, Katerina
2017-09-01
Human amniotic membrane (HAM) is used as an allograft in regenerative medicine or as a source of pluripotent cells for stem cell research. Various decontamination protocols and solutions are used to sterilize HAM before its application, but little is known about the toxicity of disinfectants on HAM cells. In this study, we tested two decontamination solutions, commercial (BASE·128) and laboratory decontamination solution (LDS), with an analogous content of antimycotic/antibiotics for their cytotoxic effect on HAM epithelial (EC) and mesenchymal stromal cells (MSC). HAM was processed in a standard way, placed on nitrocellulose scaffold, and decontaminated, following three protocols: (1) 6 h, 37 °C; (2) 24 h, room temperature; (3) 24 h, 4 °C. The viability of EC was assessed via trypan blue staining. The apoptotic cells were detected using terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL). The mean % (±SD) of dead EC (%DEC) from six fresh placentas was 12.9 ± 18.1. Decontamination increased %DEC compared to culture medium. Decontamination with BASE·128 for 6 h, 37 °C led to the highest EC viability (81.7%). Treatment with LDS at 24 h, 4 °C resulted in the lowest EC viability (55.9%) in the set. MSC were more affected by apoptosis than EC. Although the BASE·128 expresses lower toxicity compared to LDS, we present LDS as an alternative decontamination solution with a satisfactory preservation of cell viability. The basic formula of LDS will be optimised by enrichment with nutrient components, such as glucose or vitamins, to improve cell viability.
Tesfaye, Tamrat; Sithole, Bruce; Ramjugernath, Deresh; Ndlela, Luyanda
2018-02-01
Commercially processed, untreated chicken feathers are biologically hazardous due to the presence of blood-borne pathogens. Prior to valorisation, it is crucial that they are decontaminated to remove the microbial contamination. The present study focuses on evaluating the best technologies to decontaminate and pre-treat chicken feathers in order to make them suitable for valorisation. Waste chicken feathers were washed with three surfactants (sodium dodecyl sulphate) dimethyl dioctadecyl ammonium chloride, and polyoxyethylene (40) stearate) using statistically designed experiments. Process conditions were optimised using response surface methodology with a Box-Behnken experimental design. The data were compared with decontamination using an autoclave. Under optimised conditions, the microbial counts of the decontaminated and pre-treated chicken feathers were significantly reduced making them safe for handling and use for valorisation applications. Copyright © 2017 Elsevier Ltd. All rights reserved.
Okumura, Tetsu; Kondo, Hisayoshi; Nagayama, Hitomi; Makino, Toshiro; Yoshioka, Toshiharu; Yamamoto, Yasuhiro
2007-01-01
The efficiency and speed with which first responders, paramedics, and emergency physicians respond to an event caused by the release of a chemical is an important concern in all modern cities worldwide. A system for the initial triage and decontamination of victims of a chemical release was developed using colored clothes pegs of the following seven colors: red, yellow, green, black, white, and blue. Red indicates the need for emergency care, yellow for semi-emergency care, green for non-emergency care, black for expectant, white for dry decontamination, and blue for wet decontamination. The system can be employed as one of the techniques directed at improving the efficiency of decontamination in countries where there is a risk of chemical releases. It is recommended that this system should be adopted internationally and used for both drills and actual events.
Sterilization and disinfection in the physician's office.
Drummond, D C; Skidmore, A G
1991-01-01
OBJECTIVE: To review the principles and practice of sterilization and disinfection of medical instruments in the office setting. DATA SOURCES: Searches of MEDLINE for articles published from 1980 to 1990 on disinfection, sterilization, cross infection, surgical instruments and iatrogenic disease, bibliographies, standard texts and reference material located in a central processing department. STUDY SELECTION: We reviewed surveys of decontamination practices in physicians' offices, reviews of current recommendations for office decontamination procedures, case reports of cross infection in offices and much of the standard reference material on decontamination theory and practice. DATA SYNTHESIS: There have been few surveys of physicians' decontamination practices and few case reports of cross infection. Office practitioners have little access to practical information on sterilization and disinfection. CONCLUSION: The increasing threat of cross infection from medical instruments calls for greater knowledge about decontamination. We have adapted material from various sources and offer a primer on the subject. PMID:1913427
Decontaminating soil organic pollutants with manufactured nanoparticles.
Li, Qi; Chen, Xijuan; Zhuang, Jie; Chen, Xin
2016-06-01
Organic pollutants in soils might threaten the environmental and human health. Manufactured nanoparticles are capable to reduce this risk efficiently due to their relatively large capacity of sorption and degradation of organic pollutants. Stability, mobility, and reactivity of nanoparticles are prerequisites for their efficacy in soil remediation. On the basis of a brief introduction of these issues, this review provides a comprehensive summary of the application and effectiveness of various types of manufactured nanoparticles for removing organic pollutants from soil. The main categories of nanoparticles include iron (oxides), titanium dioxide, carbonaceous, palladium, and amphiphilic polymeric nanoparticles. Their advantages (e.g., unique properties and high sorption capacity) and disadvantages (e.g., high cost and low recovery) for soil remediation are discussed with respect to the characteristics of organic pollutants. The factors that influence the decontamination effects, such as properties, surfactants, solution chemistry, and soil organic matter, are addressed.
Dieguez-Elizondo, Pedro M; Gil-Lopez, Tomas; O'Donohoe, Paul G; Castejon-Navas, Juan; Galvez-Huerta, Miguel A
2017-02-01
This work focuses on studying concentration distribution of 222 Rn radioisotope in a granite processing plant. Using Computational Fluid Dynamic Techniques (CFD), the exposure of the workers to radiation was assessed and, in order to minimise this exposure, different decontamination scenarios using ventilation were analysed. Natural ventilation showed not sufficient to maintain radon concentration below acceptable limits, so a forced ventilation was used instead. Position of the granite blocks also revealed as a determining factor in the radioactive level distribution. Thus, a correct layout of the stored material and an adequate ventilation system can guarantee free of exposure to radiation zones within the studied workshop. This leads to a drastic fall in the exposure of the workers and consequently minimises their risk of developing aggressive illness like lung cancer. Copyright © 2016 Elsevier Ltd. All rights reserved.
Microbial decontamination of cosmetic raw materials and personal care products by irradiation
NASA Astrophysics Data System (ADS)
Katušin-Ražem, Branka; Mihaljević, Branka; Ražem, Dušan
2003-03-01
Typical levels of sporadically occurring (dynamic) microbial contamination of cosmetic raw materials: pigments, abrasives and liposomes, as well as of final products for personal care: toothpaste, crayons, shampoos, cleansers and creams, were evaluated. In most cases the contamination was dominated by a single population of microorganisms, either Gram-negative bacteria or molds. The feasibility of microbial decontamination by irradiation was studied by determining the resistance to gamma radiation of contaminating microflora in situ. It was expressed as a dose required for the first 90% reduction, D first 90% red . The values in the range 1-2 kGy for molds and 0.1-0.6 kGy for Gram-negative bacteria were obtained. This relatively high susceptibility to irradiation allowed inactivation factors close to 6 to be achieved with doses generally not exceeding 3 kGy, and yielding endpoint contamination less than 10/g.
Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments
2015-08-01
elements: • Expendable items: including materials such as stainless steel mixing bowls/spoons, decontamination supplies (buckets, brushes, distilled...PE samplers. Traditional sediment sampling equipment would include items such as decontamination fluids, stainless steel mixing bowls and spoons...hazardous/hazardous wastes (excess sediment, decontamination fluids). There is not expected to be a big difference in solid waste disposal costs
Small-Item Vapor Test Method, FY11 Release
2012-07-01
to this test procedure is provided alphabetically in the following list: absorption: The uptake of a contaminant INTO the volume of a material. The... powders , wipes), or gas-phase (fumigants, including aerosols). decontamination process: The process of making any person, object, or area safe by...with another contaminant. Generally, bare metals and glass are nonsorptive materials for some agents. operational decontamination: Decontamination
Decontamination Equipment Standards Workshop for Civilian First Responders
2009-12-01
Hazardous Materials Decontamination Radiological Survey Nuclear Chemical 16. SECURITY CLASSIFICATION OF: a. REPORT u b. ABSTRACT u c. THIS...Washington, DC) sponsored the production of this material under an Interagency Agreement with the National Institute of Standards and Technology...responders currently use wet decontamination (i.e., soap and water) to remove contamination from personnel, the standard will not be specific to the
Understanding Mechanism of Photocatalytic Microbial Decontamination of Environmental Wastewater
Regmi, Chhabilal; Joshi, Bhupendra; Ray, Schindra K.; Gyawali, Gobinda; Pandey, Ramesh P.
2018-01-01
Several photocatalytic nanoparticles are synthesized and studied for potential application for the degradation of organic and biological wastes. Although these materials degrade organic compounds by advance oxidation process, the exact mechanisms of microbial decontamination remains partially known. Understanding the real mechanisms of these materials for microbial cell death and growth inhibition helps to fabricate more efficient semiconductor photocatalyst for large-scale decontamination of environmental wastewater or industries and hospitals/biomedical labs generating highly pathogenic bacteria and toxic molecules containing liquid waste by designing a reactor. Recent studies on microbial decontamination by photocatalytic nanoparticles and their possible mechanisms of action is highlighted with examples in this mini review. PMID:29541632
Method and apparatus for the gas phase decontamination of chemical and biological agents
O'Neill, Hugh J.; Brubaker, Kenneth L.
2003-10-07
An apparatus and method for decontaminating chemical and biological agents using the reactive properties of both the single atomic oxygen and the hydroxyl radical for the decontamination of chemical and biological agents. The apparatus is self contained and portable and allows for the application of gas reactants directly at the required decontamination point. The system provides for the use of ultraviolet light of a specific spectral range to photolytically break down ozone into molecular oxygen and hydroxyl radicals where some of the molecular oxygen is in the first excited state. The excited molecular oxygen will combine with water vapor to produce two hydroxyl radicals.
Rogers, J V; Sabourin, C L K; Choi, Y W; Richter, W R; Rudnicki, D C; Riggs, K B; Taylor, M L; Chang, J
2005-01-01
To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. Bacillus anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to > or =1000 ppm hydrogen peroxide gas for 20 min. Hydrogen peroxide exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials except G. stearothermophilus on industrial carpet. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with both surrogates. The effectiveness of gaseous hydrogen peroxide on the growth of biological indicators and spore strips was evaluated in parallel as a qualitative assessment of decontamination. At 1 and 7 days postexposure, decontaminated biological indicators and spore strips exhibited no growth, while the nondecontaminated samples displayed growth. Significant differences in decontamination efficacy of hydrogen peroxide gas on porous and nonporous surfaces were observed when comparing the mean log reduction in B. anthracis spores with B. subtilis and G. stearothermophilus spores. These results provide comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using hydrogen peroxide gas.
Laser decontamination and decomposition of PCB-containing paint
NASA Astrophysics Data System (ADS)
Anthofer, A.; Kögler, P.; Friedrich, C.; Lippmann, W.; Hurtado, A.
2017-01-01
Decontamination of concrete surfaces contaminated with paint containing polychlorinated biphenyls is an elaborate and complex task that must be performed within the scope of nuclear power plant dismantling as well as conventional pollutant cleanup in buildings. The state of the art is mechanical decontamination, which generates dust as well as secondary waste and is both dangerous and physically demanding. Moreover, the ablated PCB-containing paint has to be treated in a separate process step. Laser technology offers a multitude of possibilities for contactless surface treatment with no restoring forces and a high potential for automation. An advanced experimental setup was developed for performing standard laser decontamination investigations on PCB-painted concrete surfaces. As tested with epoxy paints, a high-power diode laser with a laser power of 10 kW in continuous wave (CW) mode was implemented and resulted in decontamination of the concrete surfaces as well as significant PCB decomposition. The experimental results showed PCB removal of 96.8% from the concrete surface and PCB decomposition of 88.8% in the laser decontamination process. Significant PCDD/F formation was thereby avoided. A surface ablation rate of approx. 7.2 m2/h was realized.
Leary, Adam D; Schwartz, Michael D; Kirk, Mark A; Ignacio, Joselito S; Wencil, Elaine B; Cibulsky, Susan M
2014-06-01
Decontaminating patients who have been exposed to hazardous chemicals can directly benefit the patients' health by saving lives and reducing the severity of toxicity. While the importance of decontaminating patients to prevent the spread of contamination has long been recognized, its role in improving patient health outcomes has not been as widely appreciated. Acute chemical toxicity may manifest rapidly-often minutes to hours after exposure. Patient decontamination and emergency medical treatment must be initiated as early as possible to terminate further exposure and treat the effects of the dose already absorbed. In a mass exposure chemical incident, responders and receivers are faced with the challenges of determining the type of care that each patient needs (including medical treatment, decontamination, and behavioral health support), providing that care within the effective window of time, and protecting themselves from harm. The US Department of Health and Human Services and Department of Homeland Security have led the development of national planning guidance for mass patient decontamination in a chemical incident to help local communities meet these multiple, time-sensitive health demands. This report summarizes the science on which the guidance is based and the principles that form the core of the updated approach.
Park, Shin-Young; Kim, Kyoung-Hwa; Shin, Seung-Yun; Koo, Ki-Tae; Lee, Yong-Moo; Chung, Chong-Pyoung; Seol, Yang-Jo
2015-06-01
This study evaluated decontamination methods using a dental water jet and dental floss on microthreaded implants for regenerative periimplantitis therapy. In 6 beagle dogs, experimental periimplantitis was induced, and decontamination procedures, including manual saline irrigation (control group), saline irrigation using a dental water jet (group 1) and saline irrigation using a dental water jet with dental flossing (group 2), were performed. After in situ decontamination procedures, some of the implant fixtures (n = 4 per group) were retrieved for analysis by SEM, whereas other fixtures (n = 4 per group) underwent regenerative therapy. After 3 months of healing, the animals were killed. The SEM examination indicated that decontamination of the implant surfaces was the most effective in group 2, with no changes in implant surface morphology. The histological examination also revealed that group 2 achieved significantly greater amounts of newly formed bone (6.75 ± 2.19 mm; P = 0.018), reosseointegration (1.88 ± 1.79 mm; P = 0.038), and vertical bone fill (26.69 ± 18.42%; P = 0.039). Decontamination using a dental water jet and dental floss on microthreaded implants showed positive mechanical debridement effects and positive bone regeneration effects.
Lemieux, P; Wood, J; Drake, J; Minamyer, S; Silvestri, E; Yund, C; Nichols, T; Ierardi, M; Amidan, B
2016-01-01
The Bio-response Operational Testing and Evaluation (BOTE) Project was a cross-government effort designed to operationally test and evaluate a response to a biological incident (release of Bacillus anthracis [Ba] spores, the causative agent for anthrax) from initial public health and law enforcement response through environmental remediation. The BOTE Project was designed to address site remediation after the release of a Ba simulant, Bacillus atrophaeus spp. globigii (Bg), within a facility, drawing upon recent advances in the biological sampling and decontamination areas. A key component of response to a biological contamination incident is the proper management of wastes and residues, which is woven throughout all response activities. Waste is generated throughout the response and includes items like sampling media packaging materials, discarded personal protective equipment, items removed from the facility either prior to or following decontamination, aqueous waste streams, and materials generated through the application of decontamination technologies. The amount of residual contaminating agent will impact the available disposal pathways and waste management costs. Waste management is an integral part of the decontamination process and should be included through "Pre-Incident" response planning. Overall, the pH-adjusted bleach decontamination process generated the most waste from the decontamination efforts, and fumigation with chlorine dioxide generated the least waste. A majority of the solid waste generated during pH-adjusted bleach decontamination was the nonporous surfaces that were removed, bagged, decontaminated ex situ, and treated as waste. The waste during the two fumigation rounds of the BOTE Project was associated mainly with sampling activities. Waste management activities may represent a significant contribution to the overall cost of the response/recovery operation. This paper addresses the waste management activities for the BOTE field test. Management of waste is a critical element of activities dealing with remediation of buildings and outdoor areas following a biological contamination incident. Waste management must be integrated into the overall remediation process, along with sampling, decontamination, resource management, and other important response elements, rather than being a stand-alone activity. The results presented in this paper will provide decision makers and emergency planners at the federal/state/tribal/local level information that can be used to integrate waste management into an overall systems approach to planning and response activities.
Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.
Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402
Posttransplant complications in adult recipients of intestine grafts without bowel decontamination.
Clouse, Jared W; Kubal, Chandrashekhar A; Fridell, Jonathan A; Mangus, Richard S
2018-05-01
Selective digestive decontamination is commonly used to decrease lumenal bacterial flora. Preoperative bowel decontamination may be associated with a lower wound infection rate but has not been shown to decrease risk of intra-abdominal abscess or lower leak rate for enteric anastomoses. Alternatively, the decontamination disrupts the normal flora of the gastrointestinal tract and may affect normal physiology, including immunologic function. This study reports complication rates of an intestine transplant program that has never used bowel decontamination. All adult patients who underwent intestine transplant from 2003 to 2015 at a single center were reviewed. Posttransplant complications included intra-abdominal abscess, enteric fistula, and leak from the enteric anastomosis. Viral, fungal, and bacterial infections in the first year after transplant are reported. There were 184 adult patients who underwent deceased donor intestine transplant during the study period. Among these patients, 30% developed an infected postoperative fluid collection, 4 developed an enteric fistula (2%), and 16 had an enteric or anastomotic leak (8%). The rate of any bacterial infection was 91% in the first year, with a wound infection rate of 25%. Fungal infection occurred in 47% of patients. Rejection rates were 55% at 1 y for isolated intestine patients and 17% for multivisceral (liver inclusive) patients. Among this population of intestine transplant patients in which no bowel decontamination was used, rates of surgical complications, infections, and rejection were similar to those reported by other centers. Bowel decontamination provides no identifiable benefit in intestine transplantation. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Taniguchi, K.; Onda, Y.; Yoshimura, K.; Smith, H.; Brake, W.; Kubo, T.; Kuramoto, T.; Sato, T.; Onuma, S.
2016-12-01
Radionuclides such as Cs-134 and Cs-137 were widely distributed in the area affected by the accident at Fukushima Daiichi nuclear power plant. The radionuclides were deposited on the surface, absorbed by soil particles, and transported via river systems to Pacific Ocean due to rainfall events. In order to reduce air dose rate surrounding residential area, decontamination works have been conducted between 2013 and 2016 Fiscal Years. In paddy field and farmland contaminated by the fallout, 5 cm of surface soil was stripped, and then clean sands put on the surface. This work could reduce radiocaesium inventory, while the coverage of vegetation was significantly decreased. Therefore, runoff characteristics in the decontaminated area were different before and after the decontamination. Activity concentrations of particulate Cs-137 were measured in Abukuma river system and 8 small catchments located in coastal zone of Fukushima affected area. In all monitoring sites, Cs-137 concentrations have decreased over an entire monitoring period. Kuchibuto river, which is a tributary of Abukuma river showed significant effect of decontamination. In Yamakiya district, in the watershed of the tributary, the decontamination work had conducted from 2013 FY to December 2015. Particulate Cs-137 concentration at two monitoring sites located in the district showed around 30% of decline in the beginning of 2014 FY whereas the decline was not so significant at sites in lower reach of the tributary. Decontaminated paddy field and farmland can be judged as the important source of suspended sediments in the tributary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, R.P.; Hazelton, R.F.
1984-12-01
A study was conducted to evaluate the technical and economic feasibility of using in-situ decontamination techniques to convert glove boxes and other large TRU-contaminated components directly into LLW. The results of the technical evaluation indicate that in-situ decontamination of these types of components to non-TRU levels is technically feasible. Applicable decontamination techniques include electropolishing, hand scrubbing, chemical washes/sprays, strippable coatings and Freon spray-cleaning. The removal of contamination from crevices and other holdup areas remains a problem, but may be solved through further advances in decontamination technology. Also, the increase in the allowable maximum TRU level from 10 nCi/g to 100more » nCi/g as defined in DOE Order 5820.2 reduces the removal requirement and facilitates measurement of the remaining quantities. The major emphasis of the study was on a cost/benefit evaluation that included a review and update of previous analyses and evaluations of TRU-waste volume reduction and conversion options. The results of the economic evaluation show, for the assumptions used, that there is a definite cost incentive to size reduce large components, and that decontamination of sectioned material has become cost competitive with the size reduction options. In-situ decontamination appears to be the lowest cost option when based on routine-type operations conducted by well-trained and properly equipped personnel. 16 references, 1 figure, 7 tables.« less
Decontamination and disposal of PCB wastes.
Johnston, L E
1985-01-01
Decontamination and disposal processes for PCB wastes are reviewed. Processes are classed as incineration, chemical reaction or decontamination. Incineration technologies are not limited to the rigorous high temperature but include those where innovations in use of oxident, heat transfer and residue recycle are made. Chemical processes include the sodium processes, radiant energy processes and low temperature oxidations. Typical processing rates and associated costs are provided where possible. PMID:3928363
PROCESS OF DECONTAMINATING MATERIAL CONTAMINATED WITH RADIOACTIVITY
Overholt, D.C.; Peterson, M.D.; Acken, M.F.
1958-09-16
A process is described for decontaminating metallic objects, such as stainless steel equipment, which consists in contacting such objects with nltric acid in a concentration of 35 to 60% to remove the major portion of the contamination; and thereafter contacting the partially decontaminated object with a second solution containing up to 20% of alkali metal hydroxide and up to 20% sodium tartrate to remove the remaining radioactive contaminats.
2017-06-07
AUTHORS 7. PERFORMING ORGANIZATION NAMES AND ADDRESSES 15. SUBJECT TERMS b. ABSTRACT 2. REPORT TYPE 17. LIMITATION OF ABSTRACT 15. NUMBER OF PAGES 5d...Insight Into Multifunctional Reactive Adsorbents: Engaging Chemistry , Porosity, Photoactivity and Conductivity into Decontamination Process The...Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 CWA decontamination, multifunctional adsorbents, porosity, surface chemistry
2006-06-01
Decontamination assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surfaces using a hydrogen...resistant to commonly used disinfectants and require the use of chemical sterilants † to effectively decontaminate exposed areas. Since anthrax...spores can aerosolise the use of vaporous sterilants in the remediation of contaminated areas is desirable. A number of vaporous sterilants exist which
2017-12-13
Omniphobic Covalently Attached Liquid (SOCAL) December 13, 2017 Approved for public release; distribution is unlimited. Brandy J. White Brian J. Melde...Bioinspired Surface Treatments for Improved Decontamination: Slippery Omniphobic Covalently Attached Liquid (SOCAL) Brandy J. White, Brian J. Melde, Anthony...decontamination capabilities for painted surfaces. This report details results for evaluation of a slippery omniphobic covalently attached liquid (SOCAL) and
Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Arae, Hideki; Sahoo, Sarata Kumar; Janik, Miroslaw; Hosoda, Masahiro; Tokonami, Shinji
2014-02-18
Several studies have estimated inhalation doses for the public because of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Most of them were based on measurement of radioactivity in outdoor air and included the assumption that people stayed outdoors all day. Although this assumption gives a conservative estimate, it is not realistic. The "air decontamination factor" (ratio of indoor to outdoor air radionuclide concentrations) was estimated from simultaneous sampling of radioactivity in both inside and outside air of one building. The building was a workplace and located at the National Institute of Radiological Sciences (NIRS) in Chiba Prefecture, Japan. Aerosol-associated radioactive materials in air were collected onto filters, and the filters were analyzed by γ spectrometry at NIRS. The filter sampling was started on March 15, 2011 and was continued for more than 1 year. Several radionuclides, such as (131)I, (134)Cs, and (137)Cs were found by measuring the filters with a germanium detector. The air decontamination factor was around 0.64 for particulate (131)I and 0.58 for (137)Cs. These values could give implications for the ratio of indoor to outdoor radionuclide concentrations after the FDNPP accident for a similar type of building.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from several of the ''microbatches'' of Integrated Salt Disposition Project (ISDP) Salt Batch (''Macrobatch'') 6 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results from the current microbatch samples are similar to those from comparable samples in Macrobatch 5. From a bulk chemical point of view, the ICPES results do not vary considerably between this and the previous macrobatch. The titanium results in the DSSHT samples continue tomore » indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST in ARP continues to occur. Both the CST and CWT samples indicate that the target Free OH value of 0.03 has been surpassed. While at this time there is no indication that this has caused an operational problem, the CST should be adjusted into specification. The {sup 137}Cs results from the SRNL as well as F/H lab data indicate a potential decline in cesium decontamination factor. Further samples will be carefully monitored to investigate this.« less
Lahodny, G E; Gautam, R; Ivanek, R
2015-01-01
Indirect transmission through the environment, pathogen shedding by infectious hosts, replication of free-living pathogens within the environment, and environmental decontamination are suspected to play important roles in the spread and control of environmentally transmitted infectious diseases. To account for these factors, the classic Susceptible-Infectious-Recovered-Susceptible epidemic model is modified to include a compartment representing the amount of free-living pathogen within the environment. The model accounts for host demography, direct and indirect transmission, replication of free-living pathogens in the environment, and removal of free-living pathogens by natural death or environmental decontamination. Based on the assumptions of the deterministic model, a continuous-time Markov chain model is developed. An estimate for the probability of disease extinction or a major outbreak is obtained by approximating the Markov chain with a multitype branching process. Numerical simulations illustrate important differences between the deterministic and stochastic counterparts, relevant for outbreak prevention, that depend on indirect transmission, pathogen shedding by infectious hosts, replication of free-living pathogens, and environmental decontamination. The probability of a major outbreak is computed for salmonellosis in a herd of dairy cattle as well as cholera in a human population. An explicit expression for the probability of disease extinction or a major outbreak in terms of the model parameters is obtained for systems with no direct transmission or replication of free-living pathogens.
Large-Scale Urban Decontamination; Developments, Historical Examples and Lessons Learned
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rick Demmer
2007-02-01
Recent terrorist threats and actual events have lead to a renewed interest in the technical field of large scale, urban environment decontamination. One of the driving forces for this interest is the real potential for the cleanup and removal of radioactive dispersal device (RDD or “dirty bomb”) residues. In response the U. S. Government has spent many millions of dollars investigating RDD contamination and novel decontamination methodologies. Interest in chemical and biological (CB) cleanup has also peaked with the threat of terrorist action like the anthrax attack at the Hart Senate Office Building and with catastrophic natural events such asmore » Hurricane Katrina. The efficiency of cleanup response will be improved with these new developments and a better understanding of the “old reliable” methodologies. Perhaps the most interesting area of investigation for large area decontamination is that of the RDD. While primarily an economic and psychological weapon, the need to cleanup and return valuable or culturally significant resources to the public is nonetheless valid. Several private companies, universities and National Laboratories are currently developing novel RDD cleanup technologies. Because of its longstanding association with radioactive facilities, the U. S. Department of Energy National Laboratories are at the forefront in developing and testing new RDD decontamination methods. However, such cleanup technologies are likely to be fairly task specific; while many different contamination mechanisms, substrate and environmental conditions will make actual application more complicated. Some major efforts have also been made to model potential contamination, to evaluate both old and new decontamination techniques and to assess their readiness for use. Non-radioactive, CB threats each have unique decontamination challenges and recent events have provided some examples. The U. S. Environmental Protection Agency (EPA), as lead agency for these emergency cleanup responses, has a sound approach for decontamination decision-making that has been applied several times. The anthrax contamination at the U. S. Hart Senate Office Building and numerous U. S. Post Office facilities are examples of employing novel technical responses. Decontamination of the Hart Office building required development of a new approach for high level decontamination of biological contamination as well as techniques for evaluating the technology effectiveness. The World Trade Center destruction also demonstrated the need for, and successful implementation of, appropriate cleanup methodologies. There are a number of significant lessons that can be gained from a look at previous large scale cleanup projects. Too often we are quick to apply a costly “package and dispose” method when sound technological cleaning approaches are available. Understanding historical perspectives, advanced planning and constant technology improvement are essential to successful decontamination.« less
Oxidative Tritium Decontamination System
Gentile, Charles A. , Guttadora, Gregory L. , Parker, John J.
2006-02-07
The Oxidative Tritium Decontamination System, OTDS, provides a method and apparatus for reduction of tritium surface contamination on various items. The OTDS employs ozone gas as oxidizing agent to convert elemental tritium to tritium oxide. Tritium oxide vapor and excess ozone gas is purged from the OTDS, for discharge to atmosphere or transport to further process. An effluent stream is subjected to a catalytic process for the decomposition of excess ozone to diatomic oxygen. One of two configurations of the OTDS is employed: dynamic apparatus equipped with agitation mechanism and large volumetric capacity for decontamination of light items, or static apparatus equipped with pressurization and evacuation capability for decontamination of heavier, delicate, and/or valuable items.
Chemical decontamination technical resources at Los Alamos National Laboratory (2008)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, Murray E
This document supplies information resources for a person seeking to create planning or pre-planning documents for chemical decontamination operations. A building decontamination plan can be separated into four different sections: Pre-planning, Characterization, Decontamination (Initial response and also complete cleanup), and Clearance. Of the identified Los Alamos resources, they can be matched with these four sections: Pre-planning -- Dave Seidel, EO-EPP, Emergency Planning and Preparedness; David DeCroix and Bruce Letellier, D-3, Computational fluids modeling of structures; Murray E. Moore, RP-2, Aerosol sampling and ventilation engineering. Characterization (this can include development projects) -- Beth Perry, IAT-3, Nuclear Counterterrorism Response (SNIPER database); Fernandomore » Garzon, MPA-11, Sensors and Electrochemical Devices (development); George Havrilla, C-CDE, Chemical Diagnostics and Engineering; Kristen McCabe, B-7, Biosecurity and Public Health. Decontamination -- Adam Stively, EO-ER, Emergency Response; Dina Matz, IHS-IP, Industrial hygiene; Don Hickmott, EES-6, Chemical cleanup. Clearance (validation) -- Larry Ticknor, CCS-6, Statistical Sciences.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manthei, J.H.; Heitkamp, D.H.; Buettner, L.C.
1992-07-01
The acute percutaneous (bare skin) LD50 was determined for EA 2192 in the rabbit. Also established were the effective doses (ED50s) for the major toxic signs observed. Dermal, Department of Transportation (DOT), tests with rabbits indicated that VX/HTH decontaminated waste is a Class B poison after being aged only 24 hr following initiation of the decontamination procedure. The same reaction, when allowed to age through about 2 half-lives (28-30 days), was no longer a Class B poison and was nonhazardous by Code of Maryland Regulations (COMAR) toxicity criteria. The DOT tests with OXONE decontaminated/neutralized VX showed this solution to bemore » less than a Class B poison by all three routes of administration (rat oral, rat inhalation, and rabbit dermal) after only 24-hr aging and a nonhazardous material by COMAR toxicity criteria.... vx, Rat, Half-life, ED50, EA 2192, Rabbit, COMAR, Decontaminated/Neutralized, HTH, OXONE, LD50.« less
Atmospheric-pressure plasma decontamination/sterilization chamber
Herrmann, Hans W.; Selwyn, Gary S.
2001-01-01
An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.
Selective decontamination of the digestive tract.
Krueger, Wolfgang A; Unertl, Klaus E
2002-04-01
Ventilator-associated pneumonia usually originates from the patient's oropharyngeal microflora. In selective digestive decontamination, topical antibiotics are applied to the oropharynx and stomach for prevention of pneumonia and other infections, possibly reducing infection-related mortality. Selective digestive decontamination is also used for the prevention of gut-derived infections in acute necrotizing pancreatitis and liver transplantation. Despite numerous clinical trials, selective digestive decontamination remains controversial. Reduction of the incidence of pneumonia is accepted, but the extent of reduction is debated. Mortality was not reduced in most individual trials, but this finding was calculated in meta-analyses, especially for combined use of topical and systemic antibiotics in surgical ICU patients. Some investigators reported increased resistance and a shift to Gram-positive pathogens. Today, it appears that selective means not only selective suppression of pathogenic bacteria but also selection of appropriate groups of patients for underlying diseases and severity of illness, and selection of ICUs, where the endemic resistance patterns might allow the use of selective digestive decontamination at a relatively low risk for increased selection pressure.
Carter, Holly; Amlôt, Richard; Williams, Richard; Rubin, G James; Drury, John
2016-09-15
This short report presents a response to an article written by Cibulsky et al. (2016). The paper by Cibulsky et al. presents a useful and timely overview of the evidence surrounding the technical and operational aspects of mass casualty decontamination. It identifies three priority targets for future research, the third of which is how casualties' needs can be met in ways that best support compliance with and effectiveness of casualty decontamination. While further investigation into behavioural, communication and privacy issues during mass decontamination is warranted, there is now a substantial body of research in this area which is not considered in detail in the succinct summary provided by Cibulsky et al. (2016). In this short report, we summarise the available evidence around likely public behaviour during mass decontamination, effective communication strategies, and potential issues resulting from a lack of privacy. Our intention is to help further focus the research needs in this area and highlight topics on which more research is needed.
Carter, Holly; Amlôt, Richard; Williams, Richard; Rubin, G. James; Drury, John
2016-01-01
This short report presents a response to an article written by Cibulsky et al. (2016). The paper by Cibulsky et al. presents a useful and timely overview of the evidence surrounding the technical and operational aspects of mass casualty decontamination. It identifies three priority targets for future research, the third of which is how casualties' needs can be met in ways that best support compliance with and effectiveness of casualty decontamination. While further investigation into behavioural, communication and privacy issues during mass decontamination is warranted, there is now a substantial body of research in this area which is not considered in detail in the succinct summary provided by Cibulsky et al. (2016). In this short report, we summarise the available evidence around likely public behaviour during mass decontamination, effective communication strategies, and potential issues resulting from a lack of privacy. Our intention is to help further focus the research needs in this area and highlight topics on which more research is needed. PMID:27790381
Method and coating composition for protecting and decontaminating surfaces
Overhold, D C; Peterson, M D
1959-03-10
A protective coating useful in the decontamination of surfaces exposed to radioactive substances is described. This coating is placed on the surface before use and is soluble in water, allowing its easy removal in the event decontamination becomes necessary. Suitable coating compositions may be prepared by mixing a water soluble carbohydrate such as sucrose or dextrin, together with a hygroscopic agent such as calcium chloride or zinc chloride.
METHOD AND COATING COMPOSITION FOR PROTECTING AND DECONTAMINATING SURFACES
Overhold, D.C.; Peterson, M.D.
1959-03-10
A protective coating useful in the decontamination of surfaces exposed to radioactive substances is presented. This coating is placed on the surface before use and is soluble in waters allowing its easy removal in the event decontamination becomes necessary. Suitable coating compositions may be prepared by mixing a water soluble carbohydrate such as sucrose or dextrin, together with a hygroscopic agent such as calcium chloride or zinc chloride.
2009-01-01
surfaces in buildings following a terrorist attack using CB agents. Vaporized hydrogen peroxide ( VHP ) and Cl02 are decontamination technologies that...decontaminant. The focus of this technical report is the evaluation of the building interior materials and the Steris VHP technology. 15. SUBJECT...TERMS Material Compatibility VHP vaporized hydrogen peroxide 16. SECURITY CLASSIFICATION OF: a. REPORT U b. ABSTRACT U c. THIS PAGE U 17
A Survey and Evaluation of Chemical Warfare Agent-Decontaminants and Decontamination
1984-10-15
0.21 citric acid monohydrate, 0.05% detergent, and 98.251 water) all contain calcium hypochlorite and have been used for decontaminating agents from...water repellent chemicals consist of an aluminum salt of a saturated carboxylic acid (such as format, acetate, palmitate, or stearate) mixed with...been conducted. Sawdust, soil, silicone, coal dust, amine or sulfonic acid -containing polymers, organic and inorganic ion-exchange materials, and metal
Efficacy of decontamination protocol by antimicrobial treatment in Iranian Tissue Bank (ITB).
Dashti-Khavidaki, Simin; Dabardani, Fariba; Mahdavi-Mazdeh, Mitra; Ravanasa, Elham; Hosseini, Seyed Kazem
2015-09-01
Iranian Tissue Bank established in 1994 provides soft tissues for implantation in Iran. This study was designed to evaluate the efficacy of decontamination process of cardiac and soft tissues in Iranian Tissue Bank. In this bank after initial assessments, the tissues were incubated in a 5-antibiotic cocktail at room temperature for 24 h and then at 4 °C for 14 days. Contamination status was compared before and after antibiotic cocktail incubation. Of 3,315 assessed tissues, 1,057 were pericardia, 1,051 were fascia and 1,207 were other soft tissues including tibialis and aorta. The initial contamination rate was 36.86%. Pericardia showed the highest contamination rate. Klebsiella species was the most prevalent organism causing contamination. Decontamination rate after antibiotic incubation was 86.91% with the highest successful decontamination rate for fascia tissue. Klebsiella species was the major source of contamination in tissues that remained contaminated after antibiotic incubation. This may be due to resistance of this organism to applied antibiotics in the decontamination cocktail possibly due to a negative drug interaction between aminoglycoside and penicillin derivatives in this antibiotic cocktail. In conclusion collected data shows comparable efficacy of the decontamination process that is used in ITB compared with homograft banks of other countries.
Modelling Mass Casualty Decontamination Systems Informed by Field Exercise Data
Egan, Joseph R.; Amlôt, Richard
2012-01-01
In the event of a large-scale chemical release in the UK decontamination of ambulant casualties would be undertaken by the Fire and Rescue Service (FRS). The aim of this study was to track the movement of volunteer casualties at two mass decontamination field exercises using passive Radio Frequency Identification tags and detection mats that were placed at pre-defined locations. The exercise data were then used to inform a computer model of the FRS component of the mass decontamination process. Having removed all clothing and having showered, the re-dressing (termed re-robing) of casualties was found to be a bottleneck in the mass decontamination process during both exercises. Computer simulations showed that increasing the capacity of each lane of the re-robe section to accommodate 10 rather than five casualties would be optimal in general, but that a capacity of 15 might be required to accommodate vulnerable individuals. If the duration of the shower was decreased from three minutes to one minute then a per lane re-robe capacity of 20 might be necessary to maximise the throughput of casualties. In conclusion, one practical enhancement to the FRS response may be to provide at least one additional re-robe section per mass decontamination unit. PMID:23202768
Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte‐Davidson, Raquel
2017-01-01
Abstract Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non‐toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty‐two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. PMID:28990191
A multi-parametric assessment of decontamination protocols for the subglacial Lake Ellsworth probe.
Magiopoulos, I; McQuillan, J S; Burd, C L; Mowlem, M; Tsaloglou, M-N
2016-04-01
Direct measurement and sampling of pristine environments, such as subglacial lakes, without introducing contaminating microorganisms and biomolecules from the surface, represents a significant engineering and microbiological challenge. In this study, we compare methods for decontamination of titanium grade 5 surfaces, the material extensively used to construct a custom-made probe for reaching, measuring and sampling subglacial Lake Ellsworth in West Antarctica. Coupons of titanium were artificially contaminated with Pseudomonas fluorescens bacteria and then exposed to a number of decontamination procedures. The most effective sterilants were (i) hydrogen peroxide vapour, and (ii) Biocleanse™, a commercially available, detergent-based biocidal solution. After each decontamination procedure the bacteria were incapable of proliferation, and showed no evidence of metabolic activity based on the generation of adenosine triphosphate (ATP). The use of ultraviolet irradiation or ethyl alcohol solution was comparatively ineffective for sterilisation. Hydrogen peroxide vapour and ultraviolet irradiation, which directly damage nucleic acids, were the most effective methods for removing detectable DNA, which was measured using 16S rRNA gene copy number and fluorescence-based total DNA quantification. Our results have not only been used to tailor the Ellsworth probe decontamination process, but also hold value for subsequent engineering projects, where high standards of decontamination are required. Copyright © 2016 Elsevier B.V. All rights reserved.
MRSA decontamination using octenidine-based products.
Danilevicius, Mindaugas; Juzéniené, Audra; Juzénaité-Karneckiené, Indré; Veršinina, Anželika
Methicillin-resistant Staphylococcus aureus (MRSA) infections are an increasing problem worldwide with a high risk of severe illness and mortality in hospitalised patients. Patients with chronic wounds are at particular risk of developing MRSA infections. As octenidine-based products have shown promising success in decontamination in the past, the aim of the present study was to determine its efficacy, safety, and tolerability in decontaminating hospitalised MRSA-positive patients. From 1 April 2011 until 9 November 2012, 36 patients were screened MRSA-positive at the Republican Vilnius University Hospital, Vilnius, Lithuania. At least three swab tests were performed for each patient to screen for MRSA, one from each nostril and one from the perineum. In patients with wounds, an additional swab was taken from the wound surface. In the affected patients octenidine-based products were used in one or two cycles of 7 days each. In addition, adverse events were recorded and the tolerability was assessed using a 4-point scale ranging from 'very good' to 'poor'. Complete decontamination was achieved in 24 patients (67%) following treatment with the octenidine-based products. None of the patients experienced side-effects or secondary symptoms such as skin irritation or allergic reactions during the course of the study. In addition, octenidine was very well tolerated in the majority of patients (n=31; 86%). The results demonstrate that octenidine-based products are highly efficient in the multifaceted decontamination of hospitalised MRSA-positive patients. Having a range of products that can be used for full body decontamination (including the scalp and nasal passages) is of particular significance when developing an MRSA decontamination protocol, as multiple parts of the body can be affected. Combined with a favourable safety and tolerability profile, octenidine-based products thus represent a good choice in multifaceted MRSA decontamination regimes, which are necessary to curb the increasing problem of severe infections.
Time-Dependent Effects of Chlorhexidine Soaks on Grossly Contaminated Bone
2012-10-01
decontaminate . Methods: Fifty four bone segments were harvested from fresh frozen porcine legs. Each specimen was dropped onto a Mueller Hinton medium that was...P, 0.0001) and no difference between the 2%CHLand 4%CHLgroups. Conclusions: This study provides new data supporting the use of CHL to decontaminate ...bone may expedite the process of biofilm formation.1,6,7 Therefore, grossly contaminated bone seg- ments should be decontaminated with effective
Characteristics and Sampling Efficiencies of Two Personal Aerosol Samplers
2007-07-01
stainless steel and plastic; therefore, it can be decontaminated easily by immersing in decontamination solution. 9 PAS-2 PAS-1 Figure 3. Picture of PAS...portable, and easy to use for decontamination . The sampling efficiency tests were conducted with monodisperse 0.5-, 1-, and 2.1-gtm fluorescent...Scientific, Corp., Palo Alto, CA). The PSL aerosols were generated using a 24 jet Collison nebulizer and then passed through a radioactive isotope (Kr-85
1983-02-01
Phosphoric, citric or other acids may be used as coupling agent/solvents in the cleaning tank. Decontamination solutions may also be used. Ultrasonics may be...111-54 "THERMAL DECOMPOSITION USING CO2 LASER . . . . . . . . . . . . . . 111-63 >’HYDROBLASTING. III-70 (-7, ACID ETCH/ NUTRALIZATION...111-192 NITRIC ACID . . .*. . . . .\\. . . . . . . . . . . . . . . TII-197 AMMONIA • • . . . • . . . . • . . . . . .... . ...... . 111-202 DANC .1
2011-04-21
various paints , metals, and polymers.2, 11 Furthermore, some CWAs are resistant to a certain decontamination formula or react with the decontamination...The use of solid-state decontaminants increases portability, decreases weight, and could potentially be incorporated into coatings or paints and...enclosure with weather stripping . Figure 2.8: Front and top views of the focusing optics enclosure. The dashed line indicates IR beam path. A
Decontamination of Subway Infrastructure Materials ...
Report This report provides the results of an assessment to determine the decontamination efficacy of methyl bromide (MB) fumigant in inactivating Bacillus anthracis (B.a.; causative agent for anthrax) spores on materials typically found in subway system infrastructure. To facilitate future decontaminations employing MB in a subway environment, this investigation focused on finding efficacious conditions when using MB at temperatures that may be encountered in an underground subway system (i.e., temperatures lower than used in previous studies).
1997-01-01
of Chemical Decontamination Inventors Philip W. Bartram, Noel C. Dibona , James H. Buchanan and Dennis K. Rohrbaugh Abstract An absorption process of...Decontamination Inventors Philip W. Bartram, Noel C. Dibona , James H. Buchanan and Dennis K. Rohrbaugh Abstract An improved method of decontaminating a...Using a Macro-reticular Strong Acid Resin Inventors Philip W. Bartram, Noel C. Dibona , James H. Buchanan, and Dennis K. Rohrbaugh Abstract A
Fighting Ebola with novel spore decontamination technologies for the military
Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth; ...
2015-08-12
Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). Here, the basis for effectuating sterilization with FDKs is chlorine dioxide (ClO 2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercializedmore » as a dry mixed-chemical for bacterial spore decontamination.« less
NASA Astrophysics Data System (ADS)
Machhour, Hasna; El Hadrami, Ismail; Imziln, Boujamaa; Mouhib, Mohamed; Mahrouz, Mostafa
2011-04-01
Peppermint was inoculated with Escherichia coli and its decontamination was carried out by gamma irradiation at low irradiation doses (0.5, 1.0 and 2.66 kGy). The efficiency of this decontamination method was evaluated and its impact on the quality parameters of peppermint, such as the color and ash content, as well as the effect on fingerprint components such as phenols and essential oils, was studied. Gas chromatography coupled to mass spectrometry (GC/MS) and High Performance Liquid Chromatography (HPLC) were used to characterize essential oils and phenolic compounds, respectively. The results indicated a complete decontamination of peppermint after the low dose gamma irradiation without a significant loss in quality attributes.
Decontamination of biological warfare agents by a microwave plasma torch
NASA Astrophysics Data System (ADS)
Lai, Wilson; Lai, Henry; Kuo, Spencer P.; Tarasenko, Olga; Levon, Kalle
2005-02-01
A portable arc-seeded microwave plasma torch running stably with airflow is described and applied for the decontamination of biological warfare agents. Emission spectroscopy of the plasma torch indicated that this torch produced an abundance of reactive atomic oxygen that could effectively oxidize biological agents. Bacillus cereus was chosen as a simulant of Bacillus anthracis spores for biological agent in the decontamination experiments. Decontamination was performed with the airflow rate of 0.393l/s, corresponding to a maximum concentration of atomic oxygen produced by the torch. The experimental results showed that all spores were killed in less than 8 s at 3 cm distance, 12 s at 4 cm distance, and 16 s at 5 cm distance away from the nozzle of the torch.
Fighting Ebola with novel spore decontamination technologies for the military
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth
Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). Here, the basis for effectuating sterilization with FDKs is chlorine dioxide (ClO 2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercializedmore » as a dry mixed-chemical for bacterial spore decontamination.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joiner, R.L.; Harroff, H.H.; Snider, H.
1987-12-04
A rabbit model has been developed and validated for screening noninvasive candidate decontamination systems for their efficacies against topical exposure to the organophosphage chemical surety materiel (CSM), GD, polymer-thickened GD (TGD), and VX. CSM was applied to rabbits in groups of 8 on their clipped dorsa over a range of doses. Dose sites were decontaminated beginning 2 minutes after exposure with both components of the M258A1 standard field kit in the recommended sequence. Replicate LD50s were calculated for each CSM with probit analyses of the doses and lethality rates from replicate studies. A composite LD50 was calculated from the datamore » pooled across replicates for each CSM. The composite LD50 was validated for each CSM by comparing the lethality rate obtained in three replicates of 8 animals each with the population mean of 50 percent. The LD50 values obtained for the three CSM tested produced valid mortality ratios when compared to the population mean. Thus the screen is ready to test candidate decontamination systems. The screen compares the lethality rate obtained from 8 animals each dosed at the established M258A1 LD50 and decontaminated according to the manufacturer's instructions with a candidate system against the population mean of 50 percent. An M258A1-decontaminated control group of 8 animals is included to check for drift via a control chart method. Any candidate decontamination system that is as effective as or more effective than the dual-component M258A1 standard passes the screen and is a candidate for further testing.« less
Raber, Ellen; Burklund, Alison
2010-01-01
Five parameters were evaluated with surrogates of Bacillus anthracis spores to determine effective decontamination alternatives for use in a contaminated drinking water supply. The parameters were as follows: (i) type of Bacillus spore surrogate (B. thuringiensis or B. atrophaeus), (ii) spore concentration in suspension (102 and 106 spores/ml), (iii) chemical characteristics of the decontaminant (sodium dichloro-S-triazinetrione dihydrate [Dichlor], hydrogen peroxide, potassium peroxymonosulfate [Oxone], sodium hypochlorite, and VirkonS), (iv) decontaminant concentration (0.01% to 5%), and (v) exposure time to decontaminant (10 min to 1 h). Results from 138 suspension tests with appropriate controls are reported. Hydrogen peroxide at a concentration of 5% and Dichlor or sodium hypochlorite at a concentration of 2% were highly effective at spore inactivation regardless of spore type tested, spore exposure time, or spore concentration evaluated. This is the first reported study of Dichlor as an effective decontaminant for B. anthracis spore surrogates. Dichlor's desirable characteristics of high oxidation potential, high level of free chlorine, and a more neutral pH than that of other oxidizers evaluated appear to make it an excellent alternative. All three oxidizers were effective against B. atrophaeus spores in meeting the EPA biocide standard of greater than a 6-log kill after a 10-min exposure time and at lower concentrations than typically reported for biocide use. Solutions of 5% VirkonS and Oxone were less effective as decontaminants than other options evaluated in this study and did not meet the EPA's efficacy standard for a biocide, although they were found to be as effective for concentrations of 102 spores/ml. Differences in methods and procedures reported by other investigators make quantitative comparisons among studies difficult. PMID:20709855
Cao, Jie; Wang, Tong; Pu, Yinfei; Tang, Zhihui; Meng, Huanxin
2018-03-01
To investigate the effects of different decontamination treatments on microstructure of titanium (Ti) surface as well as proliferation and adhesion of human gingival fibroblasts (HGFs). Ti discs with machined (M) and sand blasted, acid etched (SAE) surfaces were treated with five different decontamination treatments: (1) stainless steel curette (SSC), ultrasonic system with (2) straight carbon fiber tip (UCF) or (3) metal tip (UM), (4) rotating Ti brush (RTB), and (5) Er:YAG laser (30 mJ/pulse at 30 Hz). Surface roughness was analyzed under optical interferometry. HGFs were cultured on each disc. Proliferation and adhesive strength were analyzed. qRT-PCR and ELISA were performed to detect the RNA and protein expression of FAK, ITGB1, COL1A1, and FN1 respectively from different Ti surfaces. Surface roughness increased on M surface. Proliferation, adhesive strength and gene expression were higher on M surface than SAE surface. Decontamination treatments affected surface parameters significantly (P < 0.001), making M surface less smooth while SAE surface became less rough. SSC, UCF, UM and RTB decreased proliferation on M surfaces significantly (P < 0.05). UCF, RTB and laser increased proliferation on SAE surface significantly (P < 0.05). UM decreased adhesive strength on M surface significantly and laser increased adhesive strength on SAE surface significantly (P < 0.05). Gene expression increased with time and was altered by decontamination treatments significantly (P < 0.001). Decontamination treatments influence surface roughness and cell behavior of HGFs. Laser might be an optimal decontamination treatment which has the least negative effect on M surface and the most positive effect on SAE surface. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lastel, Marie-Laure; Fournier, Agnès; Jurjanz, Stefan; Thomé, Jean-Pierre; Joaquim-Justo, Célia; Archimède, Harry; Mahieu, Maurice; Feidt, Cyril; Rychen, Guido
2018-02-01
Sixteen weaned male Alpine kids (Capra hircus) were subjected to a 21-day oral daily exposure of 0.05 mg kg -1 BW. d -1 of chlordecone (CLD) and 0.30 μg kg -1 BW. d -1 of each non-dioxin-like polychlorinated biphenyls (NDL-PCBs, congeners 28, 52, 101, 138, 153 and 180). Four kids, identified as the CONTA group, were slaughtered at the end of the exposure, while the remaining animals (n = 12) were fed with specific diets for an additional 21-day decontamination period before slaughtering. Kids from the DECONTA (n = 4) group were fed a control diet, while those from the AC10% and PO8% group received pellets supplemented with 10% activated carbon (AC) and 8% paraffin oil (PO), respectively. CLD and NDL-PCB levels in blood, liver, peri-renal fat and muscles from different groups were analysed to compare the decontamination dynamics of the pollutants and to determine the efficiency of AC and PO to decrease the body levels of pollutants. After the decontamination period, the CLD levels considerably decreased (more than 60%) in blood, liver, muscles and fat. Concerning NDL-PCBs, the decontamination process was much lower. Overall, CLD appeared to be less retained in kids' organism compared with NDL-PCBs, and the decontamination dynamics of these pollutants appeared to be different because of their specific physicochemical properties and lipophilicity. Furthermore, the dietary supplementation with AC or PO did not significantly affect the decontamination dynamics. Copyright © 2017 Elsevier Ltd. All rights reserved.
Berhe, Birhane; Bugssa, Gessessew; Bayisa, Sena; Alemu, Megbaru
2018-03-02
Intestinal protozoa are parasites transmitted by consumption of contaminated water and food and mainly affect children and elder people and cause considerable health problems. They are the leading causes of outpatient morbidity due to diarrhea in the developing countries. So, assessing water and food source of diarrheal patients and identifying the main associated factors for transmission of protozoan parasitic infections help for effective control measures of protozoan infections. Hence, the current study was aimed at determining the prevalence of foodborne intestinal protozoa infections and associated factors among diarrheic patients in North Ethiopia. A health facility based cross-sectional study was conducted among 223 patients with watery diarrhea in four selected government health facilities in North Ethiopia from November 2016-June 2017. A structured questionnaire was used to collect data on socio-demography of study participants and factors associated with foodborne protozoa infections. The diarrheic stool samples were collected, transported, and processed using direct wet mount, formal-ether concentration and modified ZiehlNeelson staining methods. The data were analyzed using SPSS version 21 and descriptive statistics, bi-variate, and multivariate logistic regressions were computed. P-value < 0.05 at 95% confidence interval was considered statistically significant. The overall prevalence of foodborne protozoa infection was 101 (45.3%). The predominant protozoa species identified was Entamoeba histolytica/dispar 55 (24.7%), followed by Giardia intestinalis 25 (11.2%) and Cryptosporidium species 5 (2.2%). The highest proportion of protozoa infection was observed among males (23.3%) and the age group 15-24 years (13.5%). Statistically significant associations were observed between foodborne protozoan infection and not using any type of recipe to decontaminate salads and fruits (AOR = 2.64, 95 CI: 1.34-5.19, P = 0.005) and using vinegar as a decontaminant (AOR = 2.83, 95 CI: 1.24-6.48, P = 0.014). Eating out (meals at a restaurant) on the other hand was found to be protective for foodborne protozoan infection (AOR = 0.43, 95 CI: 0.23-0.78, P = 0.006). Our study revealed that foodborne protozoa infections are of public health significance in the study area. Vinegar, which is frequently used as a recipe for decontaminating salads and fruits, is inversely related to foodborne protozoa parasite infection .
2016-02-11
process ( gas /vapor or liquid ), sampling will be conducted as soon as possible. Samples will be incubated for 12 to 48 hours (depending on the...Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 08-2-065 Developmental Testing of Liquid and Gaseous...biological decontamination protocol to analyze the efficacy of liquid and gaseous/vaporous decontaminants on military-relevant surfaces. The
Sawano, Toyoaki; Tsubokura, Masaharu; Ozaki, Akihiko; Leppold, Claire; Nomura, Shuhei; Shimada, Yuki; Ochi, Sae; Tsukada, Manabu; Nemoto, Tsuyoshi; Kato, Shigeaki; Kanazawa, Yukio; Ohira, Hiromichi
2016-12-14
To assess the prevalence of non-communicable diseases (NCDs), and whether NCDs were treated or not, among hospitalised decontamination workers who moved to radio-contaminated areas after Japan's 2011 Fukushima Daiichi Nuclear Power Plant disaster. We retrospectively extracted records of decontamination workers admitted to Minamisoma Municipal General Hospital between 1 June 2012 and 31 August 2015, from hospital records. We investigated the incidence of underlying NCDs such as hypertension, dyslipidaemia and diabetes among the decontamination workers, and their treatment status, in addition to the reasons for their hospital admission. A total of 113 decontamination workers were admitted to the hospital (112 male patients, median age of 54 years (age range: 18-69 years)). In terms of the demographics of underlying NCDs in this population, 57 of 72 hypertensive patients (79.2%), 37 of 45 dyslipidaemic patients (82.2%) and 18 of 27 hyperglycaemic patients (66.7%) had not been treated for their NCDs before admission to the hospital. A high burden of underlying NCDs was found in hospitalised decontamination workers in Fukushima. Managing underlying diseases such as hypertension, hyperlipidaemia and diabetes mellitus is essential among this population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
James, Thomas; Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte-Davidson, Raquel
2018-01-01
Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non-toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty-two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. © 2017 Crown Copyright. Journal of Applied Toxicology published by John Wiley & Sons, Ltd.
Taysse, L; Dorandeu, F; Daulon, S; Foquin, A; Perrier, N; Lallement, G; Breton, P
2011-06-01
Using the hairless mouse screening model presented in the companion paper(1) the aim of this study was to assess two skin decontaminating systems: Fuller's earth (FE) and Reactive Skin Decontamination Lotion (RSDL) against two extremely toxic chemical warfare agents that represent a special percutaneous hazard, sulphur mustard (SM) and O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX). Five minutes after being exposed on the back to either 2 µL of neat sulphur mustard or 50 µg.kg(-1) of diluted VX, mice were decontaminated. Both systems were able to reduce blisters 3 days after SM exposure. However, RSDL was found to be more efficient than FE in reducing the necrosis of the epidermis and erosion. In the case of VX exposure, RSDL, whatever the ratio of decontaminant to toxicant used (RSDL 10, 20, 50), was not able to sufficiently prevent the inhibition of plasma cholinesterases taken as a surrogate marker of exposure and toxicity. Only FE reduced significantly the ChE inhibition. Some of these observations are different from our previous results obtained in domestic swine and these changes are thus discussed in the perspective of using SKH-1 hairless mice for the initial in vivo screening of decontaminants.
Nurses' infection-control practice: hand decontamination, the use of gloves and sharp instruments.
Gould, D; Wilson-Barnett, J; Ream, E
1996-04-01
Infection is an acknowledged hospital problem. Micro-organisms are disseminated mainly via hands but there is evidence that hand decontamination, the most important means of prevention, is performed too seldom, and not always after activities likely to result in heavy contamination. Nurses themselves are exposed to risks of infection, chiefly through contact with blood and body fluids, yet it has also been reported that gloves are not always worn during contact with patients' secretions and that the handling and disposal of sharp instruments may be performed unsafely. The study reported in this paper documents nursing behaviour in relation to hand decontamination, the use of gloves and sharps, taking into consideration a number of variables which could influence practice: availability of the expertise afforded by an infection-control nurse, clinical setting, nursing workload, knowledge and the resources available to control infection. Hands were decontaminated after 28.78% of patient contacts. Hands were decontaminated after 49.85% of activities likely to result in heavy contamination. Performance was related to nursing workload and the availability of hand decontaminating agents, especially when the nurses became busy. Use of gloves when they were available also proved good, with little evidence of wasteful use. The handling and disposal of sharps were commendable for most subjects but a few grossly unsafe incidents were nevertheless witnessed, apparently not associated with any of the variables examined.
40 CFR 761.398 - Reporting and recordkeeping.
Code of Federal Regulations, 2014 CFR
2014-07-01
... into a standard operating procedure (SOP) for reference whenever the decontamination procedure is used... new solvents and validated decontamination procedures in the Federal Register. (b) Any person may...
40 CFR 761.398 - Reporting and recordkeeping.
Code of Federal Regulations, 2011 CFR
2011-07-01
... into a standard operating procedure (SOP) for reference whenever the decontamination procedure is used... new solvents and validated decontamination procedures in the Federal Register. (b) Any person may...
40 CFR 761.398 - Reporting and recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
... into a standard operating procedure (SOP) for reference whenever the decontamination procedure is used... new solvents and validated decontamination procedures in the Federal Register. (b) Any person may...
40 CFR 761.398 - Reporting and recordkeeping.
Code of Federal Regulations, 2013 CFR
2013-07-01
... into a standard operating procedure (SOP) for reference whenever the decontamination procedure is used... new solvents and validated decontamination procedures in the Federal Register. (b) Any person may...
40 CFR 761.398 - Reporting and recordkeeping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... into a standard operating procedure (SOP) for reference whenever the decontamination procedure is used... new solvents and validated decontamination procedures in the Federal Register. (b) Any person may...
Abis, Gabor S A; Stockmann, Hein B A C; van Egmond, Marjolein; Bonjer, Hendrik J; Vandenbroucke-Grauls, Christina M J E; Oosterling, Steven J
2013-12-01
Gastrointestinal surgery is associated with a high incidence of infectious complications. Selective decontamination of the digestive tract is an antimicrobial prophylaxis regimen that aims to eradicate gastrointestinal carriage of potentially pathogenic microorganisms and represents an adjunct to regular prophylaxis in surgery. Relevant studies were identified using bibliographic searches of MEDLINE, EMBASE, and the Cochrane database (period from 1970 to November 1, 2012). Only studies investigating selective decontamination of the digestive tract in gastrointestinal surgery were included. Two randomized clinical trials and one retrospective case-control trial showed significant benefit in terms of infectious complications and anastomotic leakage in colorectal surgery. Two randomized controlled trials in esophageal surgery and two randomized clinical trials in gastric surgery reported lower levels of infectious complications. Selective decontamination of the digestive tract reduces infections following esophageal, gastric, and colorectal surgeries and also appears to have beneficial effects on anastomotic leakage in colorectal surgery. We believe these results provide the basis for a large multicenter prospective study to investigate the role of selective decontamination of the digestive tract in colorectal surgery.
α-Conotoxin Decontamination Protocol Evaluation: What Works and What Doesn’t
Turner, Matthew W.; Cort, John R.; McDougal, Owen M.
2017-01-01
Nine publically available biosafety protocols for safely handling conotoxin peptides were tested to evaluate their decontamination efficacy. Circular dichroism (CD) spectroscopy and mass spectrometry (MS) were used to assess the effect of each chemical treatment on the secondary and primary structure of α-CTx MII (L10V, E11A). Of the nine decontamination methods tested, treatment with 1% (m/v) solution of the enzymatic detergent Contrex™ EZ resulted in a 76.8% decrease in α-helical content as assessed by the mean residue ellipticity at 222 nm, and partial peptide digestion was demonstrated using high performance liquid chromatography mass spectrometry (HPLC-MS). Additionally, treatment with 6% sodium hypochlorite (m/v) resulted in 80.5% decrease in α-helical content and complete digestion of the peptide. The Contrex™ EZ treatment was repeated with three additional α-conotoxins (α-CTxs), α-CTxs LvIA, ImI and PeIA, which verified the decontamination method was reasonably robust. These results support the use of either 1% Contrex™ EZ solution or 6% sodium hypochlorite in biosafety protocols for the decontamination of α-CTxs in research laboratories. PMID:28906461
Decontamination and decorporation: the clinical experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poda, G.A.
1979-01-01
Decontamination and decorporation are quite interrelated when dealing with a contaminated person. Some clinical experiences from a transuranium production facility are offered. Skin decontamination is accomplished by washing with detergent and water. Stubborn cases are treated with sodium hypochlorite followed by rinsing, and emery cloth is used on more stubborn nail or finger pad contamination. If inhaled, the usual skin cleansing followed by nasal douche with normal saline decontaminates reachable areas and one of the DTPA salts given via aerosol both decontaminates and decorporates the inner recesses. Saline laxative reduces the time inhaled, and ingested particles remain in the gastro-intestinalmore » tract. Conservatism prevails in general, but most persons found to have inhaled contamination are given a single chelation within the hour of discovery and if subsequently found to have over 10% M.P.P.B. of a soluble actinide are offered further chelation. Single dose chelation has been found to be relatively innocuous and usually sufficient. The longest case of chelation therapy spanned 2-1/4 years and encompassed 123 doses of CaNa-DTPA.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abrams, W.T.; Cope, A.W.; Orsulak, R.M.
The overall objective of Task 1 was to demonstrate an effective method for removing tenacious corrosion products in a pressurized water reactor steam generator and thus significantly reduce radiation exposure during subsequent maintenance activities. Various decontamination methods were evaluated and a multistep, low concentration chemical process originated by Kraftwerk Union A.G. (KWU) of the Federal Republic of Germany was selected. The process was further developed and tested by C-E and KWU in West Germany and at C-E's facilities in Windsor, Connecticut. C-E designed, fabricated and tested a portable system to apply the process at Millstone Point II. The decontamination ofmore » the primary channel heads of the two Millstone steam generators was performed by C-E and NUSCO during the 1983 refueling shutdown of Millstone Point II plant. Results of the decontamination were very satisfactory. NUSCO determined that a net savings of 3660 man-rem of personnel exposure was realized during the decontamination demonstration and the subsequent maintenance work on the steam generators.« less
Systems analysis of decontamination options for civilian vehicles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foltz, Greg W.; Hoette, Trisha Marie
2010-11-01
The objective of this project, which was supported by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) Chemical and Biological Division (CBD), was to investigate options for the decontamination of the exteriors and interiors of vehicles in the civilian setting in order to restore those vehicles to normal use following the release of a highly toxic chemical. The decontamination of vehicles is especially challenging because they often contain sensitive electronic equipment, multiple materials some of which strongly adsorb chemical agents, and in the case of aircraft, have very rigid material compatibility requirements (i.e., they cannot be exposedmore » to reagents that may cause even minor corrosion). A systems analysis approach was taken examine existing and future civilian vehicle decontamination capabilities.« less
Effectiveness of Spray-Based Decontamination Methods for ...
Report The objective of this project was to assess the effectiveness of spray-based common decontamination methods for inactivating Bacillus (B.) atrophaeus (surrogate for B. anthracis) spores and bacteriophage MS2 (surrogate for foot and mouth disease virus [FMDV]) on selected test surfaces (with or without a model agricultural soil load). Relocation of viable viruses or spores from the contaminated coupon surfaces into aerosol or liquid fractions during the decontamination methods was investigated. This project was conducted to support jointly held missions of the U.S. Department of Homeland Security (DHS) and the U.S. Environmental Protection Agency (EPA). Within the EPA, the project supports the mission of EPA’s Homeland Security Research Program (HSRP) by providing relevant information pertinent to the decontamination of contaminated areas resulting from a biological incident.
Yair, Simo; Ofer, Butnaro; Arik, Eisenkraft; Shai, Shrot; Yossi, Rosman; Tzvika, Dushnitsky; Amir, Krivoy
2008-01-01
One of the major challenges in dealing with chemical warfare agent (CWA) dispersal, whether in the battlefield or after a terror act, is decontamination and rehabilitation of any contaminated area. Organophosphates (OPs) are considered to be among the deadliest CWAs to date. Other OPs are used as pesticides in modern agriculture, and are considered environmentally hazardous. Current methods for OP decontamination are either dangerous or insufficiently effective. As a promising solution for this problem, bioremediation--the use of biocomponents for environmental remediation--is a potentially effective, safe, and environment-friendly method. The technology relies on several enzymatic mechanisms, and can be applied in various ways. We will review recent achievements and potential applications, such as biocatalyst-containing foams and an enzymatic sponge, for environmental as well as personal exterior decontamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
G. N. Doyle
Corrective Action Unit (CAU) 254 is located in Area 25 of the Nevada Test Site (NTS), approximately 100 kilometers (km) (62 miles) northwest of Las Vegas, Nevada. The site is located within the Reactor Maintenance, Assembly and Disassembly (R-MAD) compound and consists of Building 3126, two outdoor decontamination pads, and surrounding areas within an existing fenced area measuring approximately 50 x 37 meters (160 x 120 feet). The site was used from the early 1960s to the early 1970s as part of the Nuclear Rocket Development Station program to decontaminate test-car hardware and tooling. The site was reactivated in themore » early 1980s to decontaminate a radiologically contaminated military tank. This Closure Report (CR) describes the closure activities performed to allow un-restricted release of the R-MAD Decontamination Facility.« less
Electrolytic decontamination of conductive materials for hazardous waste management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wedman, D.E.; Martinez, H.E.; Nelson, T.O.
1996-12-31
Electrolytic removal of plutonium and americium from stainless steel and uranium surfaces has been demonstrated. Preliminary experiments were performed on the electrochemically based decontamination of type 304L stainless steel in sodium nitrate solutions to better understand the metal removal effects of varying cur-rent density, pH, and nitrate concentration parameters. Material removal rates and changes in surface morphology under these varying conditions are reported. Experimental results indicate that an electropolishing step before contamination removes surface roughness, thereby simplifying later electrolytic decontamination. Sodium nitrate based electrolytic decontamination produced the most uniform stripping of material at low to intermediate pH and at sodiummore » nitrate concentrations of 200 g L{sup -1} and higher. Stirring was also observed to increase the uniformity of the stripping process.« less
Economic analysis of recycling contaminated concrete
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stephen, A.; Ayers, K.W.; Boren, J.K.
1997-02-01
Decontamination and Decommissioning activities in the DOE complex generate large volumes of radioactively contaminated and uncontaminated concrete. Currently, this concrete is usually decontaminated, the contaminated waste is disposed of in a LLW facility and the decontaminated concrete is placed in C&D landfills. A number of alternatives to this practice are available including recycling of the concrete. Cost estimates for six alternatives were developed using a spreadsheet model. The results of this analysis show that recycling alternatives are at least as economical as current practice.
Development of Nanocrystalline Zeolite Materials for the Decontamination of Chemical Warfare Agents
2008-11-17
phosphite (CH3O)2P(O)H or DMP. There is -40-20020406080100 In te ns ity ppm a) b) c) d) * ** ** ** * * 33 37 1225 9 Figure 6. 31P MAS NMR spectra...The main objective of this research is to use novel nanocrystalline zeolite materials synthesized in our laboratories for the decontamination of...nanocrystalline zeolite materials. In these studies, we have focused our attention on the decontamination of 2-CEES and DMMP, two simulants for mustard gas
DECONTAMINATION OF NEUTRON-IRRADIATED REACTOR FUEL
Buyers, A.G.; Rosen, F.D.; Motta, E.E.
1959-12-22
A pyrometallurgical method of decontaminating neutronirradiated reactor fuel is presented. In accordance with the invention, neutron-irradiated reactor fuel may be decontaminated by countercurrently contacting the fuel with a bed of alkali and alkaine fluorides under an inert gas atmosphere and inductively melting the fuel and tracking the resulting descending molten fuel with induction heating as it passes through the bed. By this method, a large, continually fresh surface of salt is exposed to the descending molten fuel which enhances the efficiency of the scrubbing operation.
Decontamination of metals using chemical etching
Lerch, Ronald E.; Partridge, Jerry A.
1980-01-01
The invention relates to chemical etching process for reclaiming contaminated equipment wherein a reduction-oxidation system is included in a solution of nitric acid to contact the metal to be decontaminated and effect reduction of the reduction-oxidation system, and includes disposing a pair of electrodes in the reduced solution to permit passage of an electrical current between said electrodes and effect oxidation of the reduction-oxidation system to thereby regenerate the solution and provide decontaminated equipment that is essentially radioactive contamination-free.
2003-05-01
I I I I FINAL • Composition B (TNT, RDX and wax), • Tetryl, • Smokeless Powder ( Nitrocellulose /Nitrogylcerin), and • HBX (TNT, RDX, aluminum...operating-cost system. Because of its temporary, on-site configuration, this is an inherently low-cost method to decontaminate range residue. On... methods ) were evaluated and progressively improved during each test run. 022/masterdocument.doc 4-12 I I I I I I I I I I I I I I I I
Electron beam irradiation for biological decontamination of Spirulina platensis
NASA Astrophysics Data System (ADS)
Brasoveanu, Mirela; Nemtanu, Monica; Minea, R.; Grecu, Maria Nicoleta; Mazilu, Elena; Radulescu, Nora
2005-10-01
The Cyanobacterium Spirulina is commercialized for its use in health foods and for therapeutic purposes due to its valuable constituents particularly proteins and vitamins. The aim of the paper is to study the Spirulina platensis behaviour when it is electron beam irradiated for biological decontamination. Microbial load, antioxidant activity, enzymatic inhibition, electron spin resonance (ESR) and UV-Vis spectra were measured for doses up to 80 kGy. The results were correlated with doses in order to find where decontamination is efficient, keeping the Spirulina qualities.
1985-06-21
mild steel, unpainted mild steel, and porous (i.e., concrete and unglazed porcelain ) test coupons contaminated with agent to a hot-gas composition near...unpainted *’ mild steel, painted stainless steel, concrete, and unglazed porcelain * coupons contaminated with HD, GB, or VX. The detectable limit for the Sub...similar decontamination efficiency was observable in the concrete and unglazed porcelain tests for an initial dose level of 1.8 mg agent/g of material
Decontamination, decommissioning, and vendor advertorial issue, 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agnihotri, Newal
The focus of the July-August issue is on Decontamination, decommissioning, and vendor advertorials. Major articles/reports in this issue include: An interesting year ahead of us, by Tom Christopher, AREVA NP Inc.; U.S.-India Civil Nuclear Cooperation; Decontamination and recycling of retired components, by Sean P. Brushart, Electric Power Research Institute; and, ANO is 33 and going strong, by Tyler Lamberts, Entergy Nuclear Operations, Inc. The industry innovation article is: Continuous improvement process, by ReNae Kowalewski, Arkansas Nuclear One.
Ijaz, M Khalid; Zargar, Bahram; Wright, Kathryn E; Rubino, Joseph R; Sattar, Syed A
2016-09-02
Indoor air can be an important vehicle for a variety of human pathogens. This review provides examples of airborne transmission of infectious agents from experimental and field studies and discusses how airborne pathogens can contaminate other parts of the environment to give rise to secondary vehicles leading air-surface-air nexus with possible transmission to susceptible hosts. The following groups of human pathogens are covered because of their known or potential airborne spread: vegetative bacteria (staphylococci and legionellae), fungi (Aspergillus, Penicillium, and Cladosporium spp and Stachybotrys chartarum), enteric viruses (noro- and rotaviruses), respiratory viruses (influenza and coronaviruses), mycobacteria (tuberculous and nontuberculous), and bacterial spore formers (Clostridium difficile and Bacillus anthracis). An overview of methods for experimentally generating and recovering airborne human pathogens is included, along with a discussion of factors that influence microbial survival in indoor air. Available guidelines from the U.S. Environmental Protection Agency and other global regulatory bodies for the study of airborne pathogens are critically reviewed with particular reference to microbial surrogates that are recommended. Recent developments in experimental facilities to contaminate indoor air with microbial aerosols are presented, along with emerging technologies to decontaminate indoor air under field-relevant conditions. Furthermore, the role that air decontamination may play in reducing the contamination of environmental surfaces and its combined impact on interrupting the risk of pathogen spread in both domestic and institutional settings is discussed. Copyright © 2016. Published by Elsevier Inc.
Falciglia, Pietro P; Ingrao, Carlo; De Guidi, Guido; Catalfo, Alfio; Finocchiaro, Guglielmo; Farina, Marcello; Liali, Maria; Lorenzano, Giuseppe; Valastro, Gaetano; Vagliasindi, Federico G A
2018-04-01
The potential ability of microwave heating (MWH) for the remediation of marine sediments affected by severe hydrocarbon (HC) contamination was investigated. Decontamination effectiveness and environmental sustainability through a comparative Life Cycle Assessment (LCA) were addressed. Main results revealed that the application of a 650-W MWH treatment resulted in a rapid (15min) HC removal. A citric acid (CA) dose of 0.1M led to enhanced-HC removals of 76.9, 96.5 and 99.7% after 5, 10 and 15min of MW irradiation, respectively. The increase in CA dose to 0.2M resulted in a shorter successful remediation time of 10min. The exponential kinetic model adopted showed a good correlation with the experimental data with R 2 values in the 0.913-0.987 range. The nature of the MW treatment was shown to differently influence the HC fraction concentration after the irradiation process. Achieved HC removals in such a short remediation time are hardly possible by other clean-up techniques, making the studied treatment a potential excellent choice. Removal mechanisms, which allowed the enhanced-MWH to operate as a highly effective multi-step technique (pure thermal desorption+chemical washing), undoubtedly represent a key factor in the whole remediation process. The LCA highlighted that the MW technology is the most environmentally sustainable alternative for sediment decontamination applications, with a total damage, which was 75.74% lower than that associated with the EK (0.0503pt). Copyright © 2017 Elsevier B.V. All rights reserved.
Hidaka, Tomoo; Kakamu, Takeyasu; Hayakawa, Takehito; Kumagai, Tomohiro; Jinnouchi, Takanobu; Sato, Sei; Tsuji, Masayoshi; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2016-05-25
To reveal the effect of age and other factors on perceived anxiety over radiation exposure among decontamination workers in Fukushima Prefecture, Japan. A survey questionnaire was sent to 1505 workers, with questions regarding age, presence of a written employment contract, previous residence, radiation passbook ownership, presence of close persons for consultation, knowledge of how to access public assistance, and a four-point scale of radiation-related anxiety (1= "Very much," 2= "Somewhat," 3= "A little bit," and 4= "None" ). The relationships between the degree of anxiety and variables were analyzed using the chi-square test and residual analysis. In all, 512 participants responded to the questionnaire. The mean age of participants was 46.2 years (SD: 13.1, range: 18-77). Of them, 50, 233, 168, and 61 workers chose "Very much," "Somewhat," "A little bit," and "None," respectively, on the anxiety scale. Chi-square test showed that participants aged 61 years and over had higher degrees of anxiety (p<0.001). Ordinal logistic regression showed that the degree of anxiety increased if they did not have a written contract (p=0.042) or persons to consult (p=0.034) and if they routinely checked the dose rate (p=0.046). Decontamination workers who do not have a written contract or who are in socially isolated situations have greater anxiety over radiation exposure. Thus, it is important to both create supportive human relationships for consultation and enhance labor management in individual companies.
Chai, Lay-Ching; Lee, Hai-Yen; Ghazali, Farinazleen Mohd; Abu Bakar, Fatimah; Malakar, Pradeep Kumar; Nishibuchi, Mitsuaki; Nakaguchi, Yoshitsugu; Radu, Son
2008-12-01
Campylobacter jejuni was found to occur at high prevalence in the raw salad vegetables examined. Previous reports describe cross-contamination involving meat; here we investigated the occurrence of cross-contamination and decontamination events in the domestic kitchen via C. jejuni-contaminated vegetables during salad preparation. This is the first report concerning quantitative cross-contamination and decontamination involving naturally contaminated produce. The study was designed to simulate the real preparation of salad in a household kitchen, starting with washing the vegetables in tap water, then cutting the vegetables on a cutting board, followed by slicing cucumber and blanching (heating in hot water) the vegetables in 85 degrees C water. Vegetables naturally contaminated with C. jejuni were used throughout the simulation to attain realistic quantitative data. The mean of the percent transfer rates for C. jejuni from vegetable to wash water was 30.1 to 38.2%; from wash water to cucumber, it was 26.3 to 47.2%; from vegetables to cutting board, it was 1.6 to 10.3%; and from cutting board to cucumber, it was 22.6 to 73.3%. The data suggest the wash water and plastic cutting board as potential risk factors in C. jejuni transmission to consumers. Washing of the vegetables with tap water caused a 0.4-log reduction of C. jejuni attached to the vegetables (most probable number/gram), while rapid blanching reduced the number of C. jejuni organisms to an undetectable level.
Selective decontamination of the digestive tract reduces pneumonia and mortality.
Haas, Lenneke E M; Schultz, Marcus J
2010-01-01
Selective decontamination of the digestive tract (SDD) has been subject of numerous randomized controlled trials in critically ill patients. Almost all clinical trials showed SDD to prevent pneumonia. Nevertheless, SDD has remained a controversial strategy. One reason for why clinicians remained reluctant to implement SDD into daily practice could be that mortality was reduced in only 2 trials. Another reason could be the heterogeneity of trials of SDD. Indeed, many different prophylactic antimicrobial regimes were tested, and dissimilar diagnostic criteria for pneumonia were applied amongst the trials. This heterogeneity impeded interpretation and comparison of trial results. Two other hampering factors for implementation of SDD have been concerns over the risk of antimicrobial resistance and fear for escalation of costs associated with the use of prophylactic antimicrobials. This paper describes the concept of SDD, summarizes the results of published trials of SDD in mixed medical-surgical intensive care units, and rationalizes the risk of antimicrobial resistance and rise of costs associated with this potentially life-saving preventive strategy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.
2016-02-23
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). The Salt Batch 9 characterization results were previously reported. An Extraction-Scrub-Strip (ESS) test was performed to determine cesium distribution ratios (D (Cs)) and cesium concentration in the strip effluent and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a blend solvent prepared by SRNL that mimics the solvent composition currently being used atmore » the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D (Cs) value of 52.4. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This compares well against the predicted value of 56.5 from a recently created D (Cs) model« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modularmore » Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.« less
Field Equipment Cleaning and Decontamination
EPA Region 4 Science and Ecosystem Support Division (SESD), Nov. 1, 2007, document describes general and specific procedures, methods and considerations when cleaning and decontaminating sampling equipment during the course of field investigations.
40 CFR 761.378 - Decontamination, reuse, and disposal of solvents, cleaners, and equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Double Wash/Rinse Method for Decontaminating Non...
Gitteh, Ensa; Kweku Otu, Jacob; Jobarteh, Tijan; Mendy, Francis; Faal-Jawara, Isatou Tutty; Ofori-Anyinam, Nana Boatema; Ayorinde, Abigail; Secka, Ousman; Gehre, Florian
2016-12-01
To determine the culture yield and time to detection of mycobacterial growth between samples decontaminated using 0.7% chlorhexidine and sodium hydroxide-N-acetyl-l-cysteine (NaOH-NALC) and cultured on the Löwenstein-Jensen (LJ) medium. We also aimed to determine the contamination rate between the 0.7% chlorhexidine and NaOH-NALC decontamination methods. The study was carried out on 68 sputa samples (42 smear positives and 26 smear negatives). Of these 68 samples, 46 were collected from men and 26 from women with an approximate average age of 27years. All the sputum samples were decontaminated using the standard NaOH-NALC and 0.7% chlorhexidine methods. The concentrates were cultured in parallel on LJ media in which reading of the slope for mycobacterial growth was obtained daily for the first 2weeks and then weekly until week 8. The mycobacterial recovery rate, time to detection, and contamination rate were then compared. The overall recovery rate of mycobacterial growth on samples treated with both decontamination methods inoculated on LJ media is 51.5% (35/68). Specifically, mycobacterial growth rates on samples treated with 0.7% chlorhexidine and standard NaOH-NALC on LJ media were 61.8% (42/68) and 54.4% (37/68), respectively. However, the growth of Mycobacterium tuberculosis complex was faster on samples treated with 0.7% chlorhexidine than those treated with NaOH-NALC (average, 32±5days vs. 33±5.2days, respectively). The contamination rate on samples treated with 0.7% chlorhexidine was 1.5% (1/68), whereas on those treated with NaOH-NALC, the rate was 4.4% (3/68). The 0.7% chlorhexidine decontamination method is rapid and has less contamination rate in terms of mycobacterial recovery compared with the standard NaOH-NALC method. Therefore, the 0.7% chlorhexidine decontamination method would be an ideal alternative option for decontamination of sputum samples and recovery/isolation of M. tuberculosis in resource-poor countries. Copyright © 2016.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-03
... from organic chemical manufacturing, soil decontamination, and polyester resin operations. We are... Rule 464 (Organic Chemical Manufacturing Operations), VCAPCD Rule 74.29 (Soil Decontamination), and...
NASA Astrophysics Data System (ADS)
Pottage, Thomas; Walker, James; Bennett, Allan; Vrublevskis, John; Hovland, Scott
This study, funded by the European Space Agency (ESA) and undertaken by the Health Protec-tion Agency, UK supported by Systems Engineering and Assessment Ltd., was devised to select suitable current decontamination technologies for development for future manned missions to the Moon and Mars. There is a requirement to decontaminate the habitat module due to the concerns about astronaut ill health, microbial deterioration of materials and potential forward contamination in the case of Mars. In the case of the MIR space station, biodeterioration of components and materials occurred, and dangerous levels of airborne microorganisms were detected during air sampling procedures which lead to the introduction of microbial exposure limits (as MORD SSP 50260) to ensure the health of the crew. COSPAR planetary protection guidelines highlight the need to reduce any potential forward or backwards contamination issues that may occur through the use of Extra Vehicular Activity (EVA) suits whilst on Mars. Decontamination of the suit exterior must be completed before any EVA activity on Mars, whilst a further decontamination cycle must be completed after entry to the airlock following EVA. Technologies and techniques have also been investigated for the microbial reduction of the interior surfaces of the EVA suit to stop biodeterioration of the materials and protect the user from pathogenic microbe accumulation. The first work package reviewed the systems description and requirements as detailed in the statement of work. The requirements were broken down into 12 further requirement sections, where they were updated and expanded, resulted in Technical Note (TN) 1 which was then used as the base document for WP2 and WP3. WP2 investigated the current technologies available for the decontamination of the habitat module interior on missions of up to 6 months and missions that have durations of greater than 6 months. A comprehensive review was carried out for the different methods that could be employed singularly and in combination to decontaminate the habitat. From this review a trade off matrix was compiled scoring each technology on a determined set of parameters. The highest score indicated the most suitable technology. For missions up to 6 months surface cleaning using disinfectant wipes were recommended in combination with an air disinfection/filtration system. For missions greater than 6 months these techniques would be complemented by the addition of a gaseous decontamination system, which could be periodically used to reduce microbial load from inaccessible surfaces. WP3 reviewed the current technologies that could be used for the decontamination of the EVA suit, both external surfaces (after use on the Lunar and Martian surfaces) and internal surfaces. Trade off matrices were constructed to reflect the new parameters for these uses. Only physical decontamination of the exterior surface of the EVA suit is needed for Lunar mission, but for Martian missions this must be enhanced with a gaseous disinfection technology. The interior of the suit can be decontaminated using passive antimicrobial fabrics and active cleaning using disinfectant wipes. WP4 summarised the previous TNs, and included estimates of costs and timelines for the development, based on technology readiness levels, of technologies that need to be flight proven before use on a mission.
Hepiegne, P; Dall'ava, D; Clement, R; Degros, J P
1995-06-01
A chemical separation method has been developed for the determination of (99)Tc in various types of radioactive wastes. Such a method includes (i) fusion with NaOH, (ii) extraction in a column containing methyltrioctylammonium chloride, (iii) extraction by solvent with N-benzoyl-N-phenylhydroxylamine and, (iv) measurement by inductively-coupled plasma mass spectrometry (ICP-MS). From the performance standpoint, the recovery of (99)Tc, using (99m)Tc as a yield tracer, is higher than 70%. This analytical method, as developed, ensures effective decontamination with respect to the radionuclides, insofar the decontamination factors are greater than 10(+5), whenever the residual activity may be measured. Taking into account a 3sigma counting error, the detection limit obtained with the ICP-MS technique is 1.9 mBq/ml; the method enabling hence to detect activities as low as 0.3 Bq/g, with analysed samples of 0.2 g and a radiochemical yield of 70%. Studies have been dedicated to the (99)Tc measurement, using the electrothermal vaporization ICP-MS technique, which lowers the detection limit by a factor 10, with the standard solution (0.3 pg/ml), compared with the previous ICP-MS technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.; Washington, A; . Fondeur, F.
2011-09-29
Savannah River National Laboratory (SRNL) periodically analyses solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 have been previously reported. MCU has experienced a modest decline in cesium removal efficiency while processing the current feed, 'Macrobatch 3'. While the target decontamination factor (DF) is 200, the fiscal year 2011 DF average is 161. The results of the prior solvent analysis report did notmore » identify a specific factor that would correlate with the poor cesium decontamination beyond a low concentration of the suppressor, trioctylamine. New analyses of the quarterly sample are reported in this document, as well as a cross-check of {sup 137}Cs measurements for SRNL and F/H lab. Furthermore, in an attempt to discover the reason for the decline in DF at MCU, SRNL was tasked with analyzing numerous Caustic Wash Tank (CWT) and chemical feed samples.« less
Enhanced toxic cloud knockdown spray system for decontamination applications
Betty, Rita G [Rio Rancho, NM; Tucker, Mark D [Albuquerque, NM; Brockmann, John E [Albuquerque, NM; Lucero, Daniel A [Albuquerque, NM; Levin, Bruce L [Tijeras, NM; Leonard, Jonathan [Albuquerque, NM
2011-09-06
Methods and systems for knockdown and neutralization of toxic clouds of aerosolized chemical or biological warfare (CBW) agents and toxic industrial chemicals using a non-toxic, non-corrosive aqueous decontamination formulation.
Experimental assessment of disinfection procedures for eradication of Aspergillus fumigatus in food.
Gangneux, Jean-Pierre; Noussair, Latifa; Bouakline, Adel; Roux, Nicole; Lacroix, Claire; Derouin, Francis
2004-10-01
Aspergillus fumigatus spores in food may represent an infectious risk for neutropenic patients. We examined the efficiency of disinfection procedures applicable to foods for eradication of A fumigatus. Boiling and microwave treatment fully decontaminated an experimental spore suspension and naturally contaminated liquid foods (reconstituted dried food, herbal tea). Full decontamination of experimentally contaminated surfaces was only obtained with 70% ethanol or heating at 220 degrees C for 15 minutes. Pepper was decontaminated when heated for 15 minutes at 220 degrees C but not by microwaving. Fruit skin was partially decontaminated by 70% ethanol. We conclude that A fumigatus spores can be eradicated from food by heating to a temperature of at least 100 degrees C. When foods cannot be exposed to high temperature or microwaving, ethanol only partially reduces the level of surface contamination.
PYROCHEMICAL DECONTAMINATION METHOD FOR REACTOR FUEL
Buyers, A.G.
1959-06-30
A pyro-chemical method is presented for decontaminating neutron irradiated uranium and separating plutonium therefrom by contact in the molten state with a metal chloride salt. Uranium trichloride and uranium tetrachloride either alone or in admixture with alkaline metal and alkaline eanth metal fluorides under specified temperature and specified phase ratio conditions extract substantially all of the uranium from the irradiated uranium fuel together with certain fission products. The phases are then separated leaving purified uranium metal. The uranium and plutonium in the salt phase can be reduced to forin a highly decontaminated uraniumplutonium alloy. The present method possesses advantages for economically decontaminating irradiated nuclear fuel elements since irradiated fuel may be proccessed immediately after withdrawal from the reactor and the uranium need not be dissolved and later reduced to the metallic form. Accordingly, the uranium may be economically refabricated and reinserted into the reactor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bito, T.; Takase, A.
Decontamination of the living oyster was studied by Y/sup 90/or Y/sup 91/ -labeled coliform bacteria. At low temperature, precultural temperature affected the contamination of the oyster but the uptake of bacteria by the oyster was distinctly observed below 5 deg C. In a study on elapsing change of contamination, it was determined that the whole bacterial load of the oyster depended mainly on the gill, but was not negligible on the digestive tract. The contaminating rate of the oyster was successfully measured by automatic recording of the shift of radioactivity in the contaminated cultural water with a dip-type G-M countermore » ratemeter and chart recorder, because the bacterial concentration of the closed cultural water decrease according to the bacterial uptake of the oyster. On decontamination of the oyster, it was observed that the most effective temperature existed in the region of 15 to 25 deg C, and at the upper or lower of this region the decontaminating efficiency decreased. As for the exchange rate of the culture water, the decontaminating effect on the oyster was proportional to an increase of the rate to 7.5 times per hour. However, more was of no effect. An increase in the cultured water volume was harmful for the decontamination of the oyster because of the exchanging efficiency of the water. (P.C.H.)« less
Offin, Douglas G; Birkin, Peter R; Leighton, Timothy G
2014-03-14
Electrochemical and high-speed imaging techniques are used to study the abilities of ultrasonically-activated bubbles to clean out micropores. Cylindrical pores with dimensions (diameter × depth) of 500 μm × 400 μm (aspect ratio 0.8), 125 μm × 350 μm (aspect ratio 2.8) and 50 μm × 200 μm (aspect ratio 4.0) are fabricated in glass substrates. Each pore is contaminated by filling it with an electrochemically inactive blocking organic material (thickened methyl salicylate) before the substrate is placed in a solution containing an electroactive species (Fe(CN)6(3-)). An electrode is fabricated at the base of each pore and the Faradaic current is used to monitor the decontamination as a function of time. For the largest pore, decontamination driven by ultrasound (generated by a horn type transducer) and bulk fluid flow are compared. It is shown that ultrasound is much more effective than flow alone, and that bulk fluid flow at the rates used cannot decontaminate the pore completely, but that ultrasound can. In the case of the 125 μm pore, high-speed imaging is used to elucidate the cleaning mechanisms involved in ultrasonic decontamination and reveals that acoustic bubble entrapment is a key feature. The smallest pore is used to explore the limits of decontamination and it is found that ultrasound is still effective at this size under the conditions employed.
Potential biodefense model applications for portable chlorine dioxide gas production.
Stubblefield, Jeannie M; Newsome, Anthony L
2015-01-01
Development of decontamination methods and strategies to address potential infectious disease outbreaks and bioterrorism events are pertinent to this nation's biodefense strategies and general biosecurity. Chlorine dioxide (ClO2) gas has a history of use as a decontamination agent in response to an act of bioterrorism. However, the more widespread use of ClO2 gas to meet current and unforeseen decontamination needs has been hampered because the gas is too unstable for shipment and must be prepared at the application site. Newer technology allows for easy, onsite gas generation without the need for dedicated equipment, electricity, water, or personnel with advanced training. In a laboratory model system, 2 unique applications (personal protective equipment [PPE] and animal skin) were investigated in the context of potential development of decontamination protocols. Such protocols could serve to reduce human exposure to bacteria in a decontamination response effort. Chlorine dioxide gas was capable of reducing (2-7 logs of vegetative and spore-forming bacteria), and in some instances eliminating, culturable bacteria from difficult to clean areas on PPE facepieces. The gas was effective in eliminating naturally occurring bacteria on animal skin and also on skin inoculated with Bacillus spores. The culturable bacteria, including Bacillus spores, were eliminated in a time- and dose-dependent manner. Results of these studies suggested portable, easily used ClO2 gas generation systems have excellent potential for protocol development to contribute to biodefense strategies and decontamination responses to infectious disease outbreaks or other biothreat events.
Alcock, Joseph P; Barbour, Michele E; Sandy, Jonathan R; Ireland, Anthony J
2009-08-01
The purpose of this research was to investigate the effects of decontamination and clinical exposure on the elastic moduli, hardness and surface roughness of two frequently used orthodontic archwires, namely 0.020in.x0.020in. heat activated (martensitic active) nickel titanium archwires and 0.019in.x0.025in. austenitic stainless steel archwires. This study was a prospective clinical trial in which 20 consecutive patients requiring an archwire change as part of their course of orthodontic fixed appliance therapy, had either a nickel titanium or stainless steel archwire fitted as deemed clinically necessary. The effect of clinical use was determined by comparing distal end cuts of the "as received" archwires before and after decontamination, with the same retrieved archwires following clinical use and decontamination. Hardness, elastic modulus and surface roughness were determined using an atomic force microscope (AFM) coupled with a nanoindenter. The results showed that the decontamination regimen and clinical use had no statistically significant effect on the nickel titanium archwires, but did have a statistically significant effect on the steel archwires. Decontamination of the steel wires significantly increased the observed surface hardness (p=0.01) and reduced the surface roughness (p=0.02). Clinical use demonstrated a statistically significant increase in the observed elastic modulus (p<0.001) and a decrease in surface roughness (p=0.001). At present it is difficult to predict the clinical significance of these statistically significant changes in archwire properties on orthodontic tooth movement.
α-Conotoxin Decontamination Protocol Evaluation: What Works and What Doesn’t
Turner, Matthew; Cort, John; McDougal, Owen
2017-09-14
Nine publically available biosafety protocols for safely handling conotoxin peptides were tested to evaluate their decontamination efficacy. Circular dichroism (CD) spectroscopy and mass spectrometry (MS) were used to assess the effect of each chemical treatment on the secondary and primary structure of α-CTx MII [L10V, E11A]. Of the nine decontamination methods tested, treatment with 1% (m/v) solution of the enzymatic detergent Contrex™ EZ resulted in a 76.8% decrease in α-helical content as assessed by the mean residue ellipticity at 222 nm, and partial peptide digestion was demonstrated using high performance liquid chromatography mass spectrometry (HPLC-MS). Additionally, treatment with 6% sodiummore » hypochlorite (m/v) resulted in 80.5% decrease in α-helical content and complete digestion of the peptide. The Contrex™ EZ treatment was repeated with three additional α-conotoxins (α-CTxs), α-CTxs LvIA, ImI and PeIA, which verified the decontamination method was reasonably robust. These results support the use of either 1% Contrex™ EZ solution or 6% sodium hypochlorite in biosafety protocols for the decontamination of α- CTxs in research laboratories.« less
α-Conotoxin Decontamination Protocol Evaluation: What Works and What Doesn’t
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, Matthew; Cort, John; McDougal, Owen
Nine publically available biosafety protocols for safely handling conotoxin peptides were tested to evaluate their decontamination efficacy. Circular dichroism (CD) spectroscopy and mass spectrometry (MS) were used to assess the effect of each chemical treatment on the secondary and primary structure of α-CTx MII [L10V, E11A]. Of the nine decontamination methods tested, treatment with 1% (m/v) solution of the enzymatic detergent Contrex™ EZ resulted in a 76.8% decrease in α-helical content as assessed by the mean residue ellipticity at 222 nm, and partial peptide digestion was demonstrated using high performance liquid chromatography mass spectrometry (HPLC-MS). Additionally, treatment with 6% sodiummore » hypochlorite (m/v) resulted in 80.5% decrease in α-helical content and complete digestion of the peptide. The Contrex™ EZ treatment was repeated with three additional α-conotoxins (α-CTxs), α-CTxs LvIA, ImI and PeIA, which verified the decontamination method was reasonably robust. These results support the use of either 1% Contrex™ EZ solution or 6% sodium hypochlorite in biosafety protocols for the decontamination of α- CTxs in research laboratories.« less
Pesticides water decontamination in oxygen-limited conditions.
Suciu, Nicoleta Alina; Ferrari, Federico; Vasileiadis, Sotirios; Merli, Annalisa; Capri, Ettore; Trevisan, Marco
2013-01-01
This study was undertaken to develop a laboratory bioreactor, with a functioning principle similar with that of biobed systems but working in oxygen-limited conditions, suitable for decontaminating wastewater mixtures with pesticides. The system is composed by two cylindrical plastic containers. The first one, where the pesticides solution is collected, is open, whereas the second one, where the biomass is disposed, is closed. The pesticides solution was pumped at the biomass surface and subsequently recollected and disposed in the first container. Four pesticides with different physical-chemical characteristics were tested. The results obtained showed a relatively good capacity of the developed prototype to decontaminate waste water containing the mixture of pesticides. The time of the experiment, the number of cycles that the solution made in the system and the environmental temperature have a significantly influence for the decontamination of acetochlor and chlorpyrifos whereas for the decontamination of terbuthylazine and metalaxyl no significant influence was observed. Even if the present prototype could represent a valid solution to manage the water pesticides residues in a farm and to increase the confidence of bystanders and residents, the practical difficulties when replacing the biomass could represent a limit of the system.
Food decontamination using nanomaterials
USDA-ARS?s Scientific Manuscript database
The research indicates that nanomaterials including nanoemulsions are promising decontamination media for the reduction of food contaminating pathogens. The inhibitory effect of nanoparticles for pathogens could be due to deactivate cellular enzymes and DNA; disrupting of membrane permeability; and/...
Decontamination Supplies Under the Worker Protection Standard
Employers at agricultural establishments must make sure that decontamination supplies for washing off pesticides and pesticide residues are available to workers and handlers. Learn about specific requirements for the type and location of these supplies.
2010-04-01
PAB 17 2.5.2 PAB/SPC Mixtures 17 2.5.3 PAB/SPC Mixtures with Ethylene Carbonate 19 2.5.4 Peroxydone/PAB Mixtures 19 2.5.4.1 Chem Agent Testing 19...Effect of Surfactant and Ethylene Carbonate (EC) Penetrant on Decontamination of HD on CARC Painted Panels 20 5. Effect of Surfactant, Alone, on...previous peroxide-based decontaminants7 (i.e., Triton® X-100 (non-ionic surfactant) and propylene carbonate [PC]) could not be used. However, there
1985-03-01
gallons for Building 2. -... The system must be capable of wit standing caustic corrosion. • Either stainless steel or lined mild steel may be used. As...assumed that spent charcoal could be disposed in some safe manner arid would be re- placed as used. Additional costs were in luded for sampling and analysis...decontamination of all three explosives could be effected by further sequential treatment of the spent explosives decontami- nation solutions with acidic ferrous
1995-11-01
Thickener (25% naphthenic acids) (25% oleic acid) Source: NUS 1987, Departments of the Army and Air Force 1963 2-8 TOO/TBL0025 07/21/94 11:45 am bpw S-60...Assessment does not state whether incineration occurred at SWMU 1 or elsewhere. The AC containers were decontaminated at SWMU 1 by rinsing with caustic ... caustic decontaminating agents that may have been applied during disposal. Decontaminating agents used include DANC (a mixture of sodium hydroxide and
Efficacy of mineral cationic carrier against sulphur mustard in skin decontamination.
Vucemilović, Ante; Hadzija, Mirko; Jukić, Ivan
2008-12-01
The aim of this study was to evaluate decontamination (absorption) efficacy of a preparation called Mineral Cationic Carrier (MCC) against skin contamination with sulphur mustard in vivo. MCC is a synthetic preparation with known ion exchange, absorption efficiency, and bioactive potential. CBA mice were applied increasing doses of sulphur mustard on their skin and MCC was administered immediately after skin contamination. The results have confirmed the decontamination efficacy of MCC preparation, corresponding to 8.4 times the LD50 of percutaneous sulphur mustard, and call for further investigation.
Brent, Jeffrey
2013-01-01
The intention is to assess whether the fundamental principle ("the solution to pollution is dilution") should be the guide for the initial medical management of corrosive dermal exposures. The US National Library of Medicine Pubmed database was searched utilizing all combinations of the search terms "decontamination", "corrosive", and "dermal". A separate search was done specifically related to hydrofluoric acid. These searches found 69 relevant papers. Only four controlled clinical studies comparing early and intensive water decontamination with no or less dilution treatment have been published on human corrosive dermal exposures. Although the authors' conclusion in the first study of 273 patients was that those that had more intensive water irrigation tended to have less time to skin grafting and shorter periods of hospitalization, the results were not statistically significant. In the second study of 51 patients, those who had "adequate" decontamination (immediate dilution or neutralization therapy) had shortened length of stay (7.2 vs. 16.2 days), lower mortality (9.5% vs. 21%), and fewer skin grafts (19% vs. 36%) despite having slightly greater burn surface area (19.7% vs. 17.2%). However, no statistical analysis was provided. The third and fourth studies were conducted in the same center. In the third study of 35 patients, those who had "immediate" water lavage (done within 10 min of exposure and continued for at least 15 min) had significantly fewer burns that progressed to full thickness (12.5% vs. 63%; p < 0.01) and significantly shorter mean hospital stays (7.7 days vs. 20.5 days; p < 0.01) than those who did not, despite the mean total burn surface area being twice as large in the adequate water decontamination group (12% vs. 6%; p < 0.05). In the fourth study of 83 patients (35 of whom had been reported in the previous study), those who had copious water lavage within 3 min of injury were less likely to progress to full thickness burns (13.5% vs. 60.8%; p < 0.01), had fewer delayed complications (5.4% vs. 30.4%; p < 0.01) and shorter lengths of stay (6.2 vs. 22 days; p < 0.01), compared with those who did not. In a further study, water was compared to the proprietary agent Diphoterine(®) in a controlled prospective cohort study of 180 dermal alkali exposures. The Diphoterine(®) first group was decontaminated significantly faster than the water first group (median times to irrigation 1 vs. 5 min; p < 0.001). No analysis adjusted for time to decontamination was provided, so the study demonstrated that only those individuals who decontaminated early did better than those who decontaminated later. The data support water as the best decontaminating solution. It has been shown to be efficacious in clinical trials, is widely available, and inexpensive.
In vivo decontamination of the nerve agent VX using the domestic swine model.
Misik, Jan; Pavlik, Michal; Novotny, Ladislav; Pavlikova, Ruzena; Chilcott, Robert P; Cabal, Jiri; Kuca, Kamil
2012-11-01
The purpose of this in vivo study was to assess a new, putatively optimised method for mass casualty decontamination ("ORCHIDS protocol") for effectiveness in removing the chemical warfare agent VX from the skin of anaesthetised, domestic white pigs. ORCHIDS protocol consists of a 1.5-minute shower with a mild detergent (Argos™) supplemented by physical removal. A standard method of wet decontamination was used for comparison. Experimental animals were divided into four groups (A-D). Two groups were exposed to a supra-lethal percutaneous dose (5 × LD(50); 300 μg kg(-1)) of VX for 1 h prior to decontamination with either the ORCHIDS (C) or standard protocol (D). A third (B, positive control) group was exposed but not subject to decontamination. Blank controls (A) received anaesthesia and the corresponding dose of normal saline instead of VX. Observations of the clinical signs of intoxication were supplemented by measurements of whole blood cholinesterase (ChE) performed on samples of arterial blood acquired at 30-minute intervals for the duration of the study (up to 6 h). Untreated (B) animals displayed typical cholinergic signs consistent with VX intoxication (local fasciculation, mastication, salivation, pilo-erection and motor convulsions) and died 165-240 min post exposure. All animals in both decontamination treatment groups (C, D) survived the duration of the study and exhibited less severe signs of cholinergic poisoning. Thus, both the standard and ORCHIDS protocol were demonstrably effective against exposure to the potent nerve agent VX, even after a delay of 1 h. A critical advantage of the ORCHIDS protocol is the relatively short shower duration (1½ min compared to 3 min). In practice, this could substantially improve the rate at which individuals could be decontaminated by emergency responders following exposure to toxic materials such as chemical warfare agents.
Gon Ryu, Sam; Wan Lee, Hae
2015-01-01
The nerve agent, O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (VX) must be promptly eliminated following its release into the environment because it is extremely toxic, can cause death within a few minutes after exposure, acts through direct skin contact as well as inhalation, and persists in the environment for several weeks after release. A mixture of hydrogen peroxide vapor and ammonia gas was examined as a decontaminant for the removal of VX on solid surfaces at ambient temperature, and the reaction products were analyzed by gas chromatography-mass spectrometry (GC-MS) and nuclear magnetic resonance spectrometry (NMR). All the VX on glass wool filter disks was found to be eliminated after 2 h of exposure to the decontaminant mixtures, and the primary decomposition product was determined to be non-toxic ethyl methylphosphonic acid (EMPA); no toxic S-[2-(diisopropylamino)ethyl] methylphosphonothioic acid (EA-2192), which is usually produced in traditional basic hydrolysis systems, was found to be formed. However, other by-products, such as toxic O-ethyl S-vinyl methylphosphonothioate and (2-diisopropylaminoethyl) vinyl disulfide, were detected up to 150 min of exposure to the decontaminant mixture; these by-products disappeared after 3 h. The two detected vinyl byproducts were identified first in this study with the decontamination system of liquid VX on solid surfaces using a mixture of hydrogen peroxide vapor and ammonia gas. The detailed decontamination reaction networks of VX on solid surfaces produced by the mixture of hydrogen peroxide vapor and ammonia gas were suggested based on the reaction products. These findings suggest that the mixture of hydrogen peroxide vapor and ammonia gas investigated in this study is an efficient decontaminant mixture for the removal of VX on solid surfaces at ambient temperature despite the formation of a toxic by-product in the reaction process.
Code of Federal Regulations, 2010 CFR
2010-01-01
... enactment of UMTRCA to perform decontamination, decommissioning, reclamation, and other remedial action... contaminated soil, disposal of process wastes, removal actions, air pollution abatement measures, mill and... subpart C of this part. Decontamination, decommissioning, reclamation, and other remedial action means...
Defending Against Biological and Chemical Attacks
2010-08-01
addition, we field integrated installation consequence management response capabilities to select installations both at home and abroad. Just as...decon- tamination, like self-decontaminating or strippable coat- ings for vehicles; we are developing technologies to focus decontamination on the
The invention concerns novel clothing fabrics containing microcapsules in a resin finish comprising reactive chemical decontamination agents...allowing the toxic chemicals to diffuse into the microcapsules where they undergo irreversible detoxifying chemical reactions.
de Vries-Hospers, H G; Sleijfer, D T; Mulder, N H; van der Waaij, D; Neiweg, H O; van Saene, H K
1981-01-01
We describe the bacteriological results of a controlled clinical trial of selective decontamination of the digestive tract as a method of infection prevention in granulocytopenic patients. Selective elimination of Enterobacteriaceae and Pseudomonadaceae species was accomplished by the oral administration of nalidixic acid, co-trimoxazole, or polymyxin. Yeasts were eliminated selectively by amphotericin B or nystatin treatment. The drugs used in this study were chosen because of their capacities to selectively eliminate gram-negative rods and yeast without affecting the anaerobic part of the gut flora which is responsible for colonization resistance. Compared with the control group, the selectively decontaminated patients had significantly fewer (P less than 0.0005) gram-negative rods or yeasts or both in their throat swab cultures and in their feces. This reduction may explain the clinical effectiveness of selective decontamination. PMID:7027923
Athiban, Prakash P; Borthakur, Bikash Jyoti; Ganesan, S; Swathika, B
2012-07-01
The aim of this study was to evaluate the antimicrobial efficacy of Aloe vera and to determine its effectiveness in decontaminating gutta percha cones. A concentrated extract of Aloe vera was used to check for the antimicrobial efficacy using the agar well diffusion method. Presence of zones' of diffusion was identified against three common GP contaminants namely, E.coli, E.faecalis and Staph. aureus. New GP Cones, freshly taken out of the packet were then decontaminated for 1minute using Aloe vera gel and then placed in thioglycolate broth to check for the presence of turbidity. The zones of inhibition on the agar plate were measured as 24mm,21mm and 24mm respectively. The broth remained clear even after 48 hours of incubation. We conclude that Aloe vera is indeed effective as a GP decontaminant and it holds a promising future as a medium for storage of GP cones.
Full Scale Drinking Water System Decontamination at the Water Security Test Bed.
Szabo, Jeffrey; Hall, John; Reese, Steve; Goodrich, Jim; Panguluri, Sri; Meiners, Greg; Ernst, Hiba
2018-03-20
The EPA's Water Security Test Bed (WSTB) facility is a full-scale representation of a drinking water distribution system. In collaboration with the Idaho National Laboratory (INL), EPA designed the WSTB facility to support full-scale evaluations of water infrastructure decontamination, real-time sensors, mobile water treatment systems, and decontamination of premise plumbing and appliances. The EPA research focused on decontamination of 1) Bacillus globigii (BG) spores, a non-pathogenic surrogate for Bacillus anthracis and 2) Bakken crude oil. Flushing and chlorination effectively removed most BG spores from the bulk water but BG spores still remained on the pipe wall coupons. Soluble oil components of Bakken crude oil were removed by flushing although oil components persisted in the dishwasher and refrigerator water dispenser. Using this full-scale distribution system allows EPA to 1) test contaminants without any human health or ecological risk and 2) inform water systems on effective methodologies responding to possible contamination incidents.
DECONTAMINATION AND BENEFICIAL USE OF DREDGED MATERIALS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
STERN, E.A.; LODGE, J.; JONES, K.W.
2000-12-03
Our group is leading a large-sale demonstration of dredged material decontamination technologies for the New York/New Jersey Harbor. The goal of the project is to assemble a complete system for economic transformation of contaminated dredged material into an environmentally-benign material used in the manufacture of a variety of beneficial use products. This requires the integration of scientific, engineering, business, and policy issues on matters that include basic knowledge of sediment properties, contaminant distribution visualization, sediment toxicity, dredging and dewatering techniques, decontamination technologies, and product manufacturing technologies and marketing. A summary of the present status of the system demonstrations including themore » use of both existing and new manufacturing facilities is given here. These decontamination systems should serve as a model for use in dredged material management plans of regions other than NY/NJ Harbor, such as Long Island Sound, where new approaches to the handling of contaminated sediments are desirable.« less
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
Dwell time considerations for large area cold plasma decontamination
NASA Astrophysics Data System (ADS)
Konesky, Gregory
2009-05-01
Atmospheric discharge cold plasmas have been shown to be effective in the reduction of pathogenic bacteria and spores and in the decontamination of simulated chemical warfare agents, without the generation of toxic or harmful by-products. Cold plasmas may also be useful in assisting cleanup of radiological "dirty bombs." For practical applications in realistic scenarios, the plasma applicator must have both a large area of coverage, and a reasonably short dwell time. However, the literature contains a wide range of reported dwell times, from a few seconds to several minutes, needed to achieve a given level of reduction. This is largely due to different experimental conditions, and especially, different methods of generating the decontaminating plasma. We consider these different approaches and attempt to draw equivalencies among them, and use this to develop requirements for a practical, field-deployable plasma decontamination system. A plasma applicator with 12 square inches area and integral high voltage, high frequency generator is described.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of chemical contamination on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some chemical contaminants, but important data gaps remain. In general, data on chemical persistence on drinking water infrastructure is available for inorganics such as arsenic and mercury, as well as select organics such as petroleum products, pesticides and rodenticides. Data specific to chemical warfare agents and pharmaceuticals was not found and data on toxins is scant. Future research suggestions focus on expanding the available chemical persistence data to other common drinking water infrastructure materials. Decontaminating agents that successfully removed persistent contamination from one infrastructure material should be used in further studies. Methods for sampling or extracting chemical agents from water infrastructure surfaces are needed. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Ioanid, E. G.; Dunca, S.; Rusu, D.; Tǎnase, C.
2012-04-01
Documents decontamination using dry methods, less invasive than the wet ones implying toxic nocuous substances for cellulose-based materials, has been the object of numerous studies. In recent years mixed researchers teams have been studying the possibility of one-step document decontamination performed by a dry treatment, the risks of repeated wet manipulation thus being reduced. Among physical methods appropriate to this end, high-frequency cold plasma and corona effect can be mentioned. Our studies were carried out on samples taken from ancient books with no cultural heritage value. The decontamination efficiency and the impact on paper of the two types of treatments were determined by: microbiological analysis, scanning electron microscopy, FTIR, chromatic alterations and gloss determination. The above-mentioned procedures eliminate the use of chemical conservation substances, nocuous for the paper support. At the same time the health risk for conservators, restorers, archivists or archive's users is removed.
NASA Astrophysics Data System (ADS)
Sentis, Marc L.; Delaporte, Philippe C.; Marine, Wladimir; Uteza, Olivier P.
2000-04-01
The application of excimer laser ablation process to the decontamination of radioactive surfaces is discussed. This technology is very attractive because it allows to efficiently remove the contaminated particles without secondary waste production. To demonstrate the capability of such technology to efficiently decontaminate large area, we studied and developed a prototype which include a XeCl laser, an optical fiber delivery system and an ablated particles collection cell. The main physical processes taking place during UV laser ablation will be explained. The influence of laser wavelength, pulse duration and absorption coefficient of material will be discussed. Special studies have been performed to understand the processes which limit the transmission of high average power excimer laser through optical fiber, and to determine the laser conditions to optimize the value of this transmission. An in-situ spectroscopic analysis of laser ablation plasma allows the real time control of the decontamination. The results obtained for painting or metallic oxides removal from stainless steel surfaces will be presented.
Rana, Sudha; Sharma, Navneet; Ojha, Himanshu; Shivkumar, Hosakote Gurumalappa; Sultana, Sarwat; Sharma, Rakesh Kumar
2014-05-01
This study aimed to develop p-tertbutylcalix[4]arene o/w nanoemulsion for decontamination of radioisotopes from skin. Formulation was characterized using dynamic light scattering (DLS), transmission electron microscopy (TEM), multi-photon confocal microscopy techniques and in vitro dissolution studies. In vivo evaluation of nano-emulsion was done using nuclear medicine technique. Stability studies and dermal toxicity studies were also carried out. Comparative decontamination efficacy (DE) studies were performed on synthetic human tissue equivalent material and Sprague Dawley rat against three commonly used medical radioisotopes, i.e., Technetium-99m ((99m)Tc), Iodine-131 ((131)I) and Thallium-201 ((201)Tl). Decontamination was performed using cotton swabs soaked in nanoemulsion at different time intervals of contaminants exposure. Whole body imaging and static counts were recorded using gamma camera before and after each decontamination attempt data was analyzed using one way analysis of variance (ANOVA) and found to be statistically significant (p<0.05). DE of the nanoemulsion loaded with p-tertbutylcalix[4]arene was observed to be 88±5%, 90±3% and 89±3% for (99m)Tc, (131)I and (201)Tl respectively. Dermal toxicity studies revealed no significant differences between treated and control animals. Skin histopathology slides with and without API (Active pharmaceutical ingredients) also found to be comparable. p-Tertbutylcalix[4]arene loaded nanoemulsion shows great promise for skin decontamination against broad ranges of radiological contaminants besides being stable and safe. Copyright © 2014 Elsevier B.V. All rights reserved.
de Waal, Yvonne C M; Raghoebar, Gerry M; Huddleston Slater, James J R; Meijer, Henny J A; Winkel, Edwin G; van Winkelhoff, Arie Jan
2013-02-01
The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. Thirty patients (79 implants) with peri-implantitis were treated with resective surgical treatment consisting of apically re-positioned flap, bone re-contouring and surface debridement and decontamination. Patients were randomly allocated to decontamination with 0.12% CHX + 0.05% CPC (test-group) or a placebo-solution (without CHX/CPC, placebo-group). Microbiological parameters were recorded during surgery; clinical and radiographical parameters were recorded before (pre-) treatment (baseline), and at 3, 6 and 12 months after treatment. Nine implants in two patients in the placebo-group were lost due to severe persisting peri-implantitis. Both decontamination procedures resulted in significant reductions of bacterial load on the implant surface, but the test-group showed a significantly greater reduction than the placebo-group (log 4.21 ± 1.89 versus log 2.77 ± 2.12, p = 0.006). Multilevel analysis showed no differences between both groups in the effect of the intervention on bleeding, suppuration, probing pocket depth and radiographical bone loss over time. Implant surface decontamination with 0.12% CHX + 0.05% CPC in resective surgical treatment of peri-implantitis leads to a greater immediate suppression of anaerobic bacteria on the implant surface than a placebo-solution, but does not lead to superior clinical results. The long-term microbiological effect remains unknown. © 2012 John Wiley & Sons A/S.
Biofilm on the tracheoesophageal voice prosthesis: considerations for oral decontamination.
Somogyi-Ganss, Eszter; Chambers, Mark S; Lewin, Jan S; Tarrand, Jeffrey J; Hutcheson, Katherine A
2017-01-01
The tracheoesophageal puncture (TEP) restores verbal communication after total laryngectomy using a one-way valved voice prosthesis (VP). Microbial colonization can shorten VP device life. Our aims were to investigate patterns of prosthetic and oral colonization, and record changes in VP device life after targeted decontamination. We conducted a retrospective review of TEP clinic patients who underwent microbial analysis of the VP between 01/2003 and 07/2013. Two subgroups were analyzed: (1) patients with microbial analysis of the VP and the mouth were analyzed to identify patterns of common contamination, and (2) patients who were prescribed targeted oral decontamination on the basis of the microbial analysis of the VP were analyzed to evaluate effects on device life. Among 42 patients, 3 patients had only fungal, 5 only bacterial, and 33 had polyspecies fungal and bacterial colonization. In the TEP-oral microflora subgroup (n = 15), 7 had common microorganisms in the mouth and on the VP. Among the decontamination subgroup (n = 23), 6 patients received broad spectrum rinse, 16 antifungal agents and 13 antibiotics, or a combination thereof. After targeted decontamination, the median device life of prostheses improved from 7.89 to 10.82 weeks (p = 0.260). The majority of patients with a suboptimal VP device life in this pilot had polyspecies bacterial and fungal colonization. VPs rarely had fungal contamination alone (3 %), and non-albicans fungal species were more common than expected. For these reasons, we are exploring the use of targeted decontamination regimens that were associated with 1.4-fold improvement in VP duration.
Pathogen Decontamination of Food Crop Soil: A Review.
Gurtler, Joshua B
2017-09-01
The purpose of this review is to delineate means of decontaminating soil. This information might be used to mitigate soil-associated risks of foodborne pathogens. The majority of the research in the published literature involves inactivation of plant pathogens in soil, i.e., those pathogens harmful to fruit and vegetable production and ornamental plants. Very little has been published regarding the inactivation of foodborne human pathogens in crop soil. Nevertheless, because decontamination techniques for plant pathogens might also be useful methods for eliminating foodborne pathogens, this review also includes inactivation of plant pathogens, with appropriate discussion and comparisons, in the hopes that these methods may one day be validated against foodborne pathogens. Some of the major soil decontamination methods that have been investigated and are covered include chemical decontamination (chemigation), solarization, steaming, biofumigation, bacterial competitive exclusion, torch flaming, microwave treatment, and amendment with biochar. Other innovative means of inactivating foodborne pathogens in soils may be discovered and explored in the future, provided that these techniques are economically feasible in terms of chemicals, equipment, and labor. Food microbiology and food safety researchers should reach out to soil scientists and plant pathologists to create links where they do not currently exist and strengthen relationships where they do exist to take advantage of multidisciplinary skills. In time, agricultural output and the demand for fresh produce will increase. With advances in the sensitivity of pathogen testing and epidemiological tracebacks, the need to mitigate preharvest bacterial contamination of fresh produce will become paramount. Hence, soil decontamination technologies may become more economically feasible and practical in light of increasing the microbial safety of fresh produce.
Nuclear decontamination technology evaluation to address contamination of a municipal water system
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFee, J.; Langsted, J.; Young, M.
The US Environmental Protection Agency (EPA) and US Department of Homeland Security (DHS) are considering the impact and recovery from contamination of municipal water systems, including intentional contamination of those systems. Industrial chemicals, biological agents, drugs, pesticides, chemical warfare agents, and radionuclides all could be introduced into a municipal water system to create detrimental health effects and disrupt a community. Although unintentional, the 1993 cryptosporidium contamination of the Milwaukee WS water system resulted in 100 fatalities and disrupted the city for weeks. Shaw Environmental and Infrastructure Inc, (Shaw), as a subcontractor on a DHS contract with Michael Baker Jr., Inc.,more » was responsible for evaluation of the impact and recovery from radionuclide contamination in a municipal water system distribution system. Shaw was tasked to develop a matrix of nuclear industry decontamination technologies and evaluate applicability to municipal water systems. Shaw expanded the evaluation to include decontamination methods commonly used in the drinking water supply. The matrix compared all technologies for implementability, effectiveness, and cost. To address the very broad range of contaminants and contamination scenarios, Shaw bounded the problem by identification of specific contaminant release scenario(s) for specific water system architecture(s). A decontamination technology matrix was developed containing fifty-nine decontamination technologies potentially applicable to the water distribution system piping, pumps, tanks, associated equipment, and/or contaminated water. Qualitatively, the majority of the nuclear industry decontamination technologies were eliminated from consideration due to implementability concerns. However, inclusion of the municipal water system technologies supported recommendations that combined the most effective approaches in both industries. (authors)« less
Applying Crowd Psychology to Develop Recommendations for the Management of Mass Decontamination
Drury, John; Rubin, G. James; Williams, Richard; Amlôt, Richard
2015-01-01
Mass decontamination is a public health intervention employed by emergency responders following a chemical, biological, or radiological release. It involves a crowd of people whose interactions with each other and with the emergency responders managing the incident are likely to affect the success of the decontamination process. The way in which members of the public collectively experience decontamination is likely to affect their behavior and hence is crucial to the success of the decontamination process. Consequently, responders and the responsible authorities need to understand crowd psychology during mass emergencies and disasters. Recently, the social identity approach to crowd psychology has been applied to explain public perceptions and behavior during mass emergencies. This approach emphasizes that crowd events are characteristically intergroup encounters, in which the behavior of one group can affect the perceptions and behavior of another. We summarize the results from a program of research in which the social identity approach was applied to develop and test recommendations for the management of mass decontamination. The findings from this program of research show that (1) responders' perceptions of crowd behavior matter; (2) participants value greater communication and this affects their compliance; and (3) social identity processes explain the relationship between effective responder communication and relevant outcome variables, such as public compliance, public cooperation, and public anxiety. Based on this program of research, we recommend 4 responder management strategies that focus on increasing public compliance, increasing orderly and cooperative behavior among members of the public, reducing public anxiety, and respecting public needs for privacy. PMID:25812428
Li, Yanqin; Gao, Qi; Zhang, Lijuan; Zhou, Yunshan; Zhong, Yuxu; Ying, Ying; Zhang, Mingcai; Huang, Chunqian; Wang, Yong'an
2018-05-08
Currently extensive effort is compulsively expended to decontaminate efficiently banned chemical war agents. In this work, H5PV2Mo10O40 molecules have been encapsulated in mesoporous MIL-101(Cr), which features two types of mesoporous cages (internal diameters of 29 Å and 34 Å) and microporous windows (diameters of 12 Å and 16 Å), leading to the formation of a new composite H5PV2Mo10O40@MIL-101(Cr) through a simple impregnation method. The composite was characterized thoroughly by elemental analysis, FT-IR spectroscopy, powder X-ray diffraction, scanning electron microscopy, energy dispersive X-ray spectroscopy, TG/DTA, and textural analysis thereby confirming the encapsulation of the H5PV2Mo10O40 into MIL-101(Cr). The decontamination efficiency of sulfur mustard (4 μL HD in 40 μL of petroleum ether) by 20 mg of the composite is found to be 97.39% in 120 min under ambient conditions. GC-MS analysis on the decontaminated products using 2-chloroethyl ethyl sulfide (CEES), which has been widely used as a simulant of sulfur mustard, showed that MIL-101(Cr) just decontaminates CEES by adsorption, while CEES can be decontaminated under ambient conditions by a synergetic combination of adsorption of MIL-101(Cr) and subsequent chemical oxidation degradation to nontoxic 2-chloroethyl ethyl sulfoxide (CEESO) due to the presence of highly dispersed H5PV2Mo10O40 within the composites.
André, Carolina Bosso; Dos Santos, Andressa; Pfeifer, Carmem Silvia; Giannini, Marcelo; Girotto, Emerson Marcelo; Ferracane, Jack Liborio
2018-04-01
This study evaluated three different sterilization/disinfection techniques for resin composites on bacterial growth and surface modification after decontamination. Two resin composites were sterilized/disinfected with three different techniques: UV light, 1% chloramine T, and 70% ethanol. Four different times were used for each technique to determine the shortest time that the solution or UV light was effective. The influence of sterilization/disinfection technique on bacterial growth was evaluated by analyzing the metabolic activity, using the AlamarBlue™ assay, bacterial viability, and SEM images from biofilms of Streptococcus mutans. The surface change, after the process, was analyzed with ATR/FTIR and SEM images. The solutions used for decontamination (1% chloramine-T and 70% ethanol) were analyzed with 1 H-NMR to identify any resin compounds leached during the process. One minute of decontamination was efficient for all three methods tested. Chloramine-T increased the surface porosity on resin composites, no changes were observed for UV light and 70% ethanol, however, 1 H-NMR identified leached monomers only when 70% ethanol was used. No chemical change of the materials was found under ATR/FTIR analyses after the decontamination process. Chloramine-T, with no previous wash, increased the bacterial viability for both resin composites and increased the bacterial metabolism for the resin composite without fluoride. UV light had no interference on the resin composites properties tested using 1 min of exposure compared to the other decontamination methods. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 945-953, 2018. © 2017 Wiley Periodicals, Inc.
Nonacid meat decontamination technologies: model studies and commercial applications.
Sofos, J N; Smith, G C
1998-11-10
Increased consumer awareness and concern about microbial foodborne diseases has resulted in intensified efforts to reduce contamination of raw meat, as evidenced by new meat and poultry inspection regulations being implemented in the United States. In addition to requiring operation of meat and poultry slaughtering and processing plants under the principles of the hazard analysis critical control point (HACCP) system, the new regulations have established microbiological testing criteria for Escherichia coli and Salmonella, as a means of evaluating plant performance. These developments have renewed and intensified interest in the development and commercial application of meat and poultry decontamination procedures. Technologies developed and evaluated for decontamination include live animal cleaning/washing, chemical dehairing, carcass knife-trimming to remove physical contaminants, steam/hot water-vacuuming for spot-cleaning/decontamination of carcasses, spray washing/rinsing of carcasses with water of low or high pressures and temperatures or chemical solutions, and exposure of carcass sides to pressurized steam. Under appropriate conditions, the technologies applied to carcasses may reduce mean microbiological counts by approximately one-three log colony forming units (cfu)/cm2, and some of them have been approved and are employed in commercial applications (i.e., steam-vacuuming; carcass spray-washing with water, chlorine, organic acid or trisodium phosphate solutions; hot water deluging/spraying/rinsing, and pressurized steam). The contribution of these decontamination technologies to the enhancement of food safety will be determined over the long term, as surveillance data on microbial foodborne illness are collected. This review examines carcass decontamination technologies, other than organic acids, with emphasis placed on recent advances and commercial applications.
Moore, C A; Wilkinson, S C; Blain, P G; Dunn, M; Aust, G A; Williams, F M
2014-08-17
Organophosphates (OPs) are widely used in agriculture. Many studies have investigated the capability of personal protective equipment (PPE) to reduce chemical exposure; however, investigations into the protective effect of 'every-day' clothing are rare. The purpose of this study was to investigate the protective effect of 'every-day' clothing against dermal exposure and to measure early decontamination of skin following exposure to chlorpyrifos and dichlorvos. Using human skin in vitro, absorption of (14)C-labelled chlorpyrifos (500 ng/cm(2)), was shown to be significantly reduced when applied to clothed skin (cotton shirt), regardless of application vehicle (isopropanol (IPA) or propylene glycol (PG)). The majority of applied dose was retained within the clothing after 4 h exposure. Significant reduction in absorption of chlorpyrifos (in PG) was seen through clothed skin when supplemented with skin decontamination at 4 h, compared with clothed skin decontaminated after 24 h, however, this was not observed with IPA. Absorption of dichlorvos (5 μg/cm(2)) was greater through unclothed skin than chlorpyrifos for all vehicles (IPA, isopropyl myristate (IPM) and PG). Significant reduction in absorption was observed when decontaminating clothed skin at 30 min, compared with decontamination at 24 h (post-exposure) for all vehicles. indicate that 'every-day' clothing is effective at reducing exposure to chemicals in contact with skin. Washing the skin surface immediately following removal of exposed clothing can further reduce exposure, depending on the properties of the chemical and vehicle applied. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Applying crowd psychology to develop recommendations for the management of mass decontamination.
Carter, Holly; Drury, John; Rubin, G James; Williams, Richard; Amlôt, Richard
2015-01-01
Mass decontamination is a public health intervention employed by emergency responders following a chemical, biological, or radiological release. It involves a crowd of people whose interactions with each other and with the emergency responders managing the incident are likely to affect the success of the decontamination process. The way in which members of the public collectively experience decontamination is likely to affect their behavior and hence is crucial to the success of the decontamination process. Consequently, responders and the responsible authorities need to understand crowd psychology during mass emergencies and disasters. Recently, the social identity approach to crowd psychology has been applied to explain public perceptions and behavior during mass emergencies. This approach emphasizes that crowd events are characteristically intergroup encounters, in which the behavior of one group can affect the perceptions and behavior of another. We summarize the results from a program of research in which the social identity approach was applied to develop and test recommendations for the management of mass decontamination. The findings from this program of research show that (1) responders' perceptions of crowd behavior matter; (2) participants value greater communication and this affects their compliance; and (3) social identity processes explain the relationship between effective responder communication and relevant outcome variables, such as public compliance, public cooperation, and public anxiety. Based on this program of research, we recommend 4 responder management strategies that focus on increasing public compliance, increasing orderly and cooperative behavior among members of the public, reducing public anxiety, and respecting public needs for privacy.
Kellner, Sophia Ricarda; Schulze-Geisthoevel, Sophia Veronika; Hack, Sylvia; Engelhart, Steffen; Bodenstein, Isabel; Al-Sabti, Nahed; Reif, Marion; Fimmers, Rolf; Körber-Irrgang, Barbara; Harlizius, Jürgen; Hoerauf, Achim; Exner, Martin; Bierbaum, Gabriele; Petersen, Brigitte
2015-01-01
Colonization of livestock with bacteria resistant to antibiotics is considered a risk for the entry of drug-resistant pathogens into the food chain. For this reason, there is a need for novel concepts to address the eradication of drug-resistant commensals on farms. In the present report, we evaluated the decontamination measures taken on a farm contaminated with methicillin-resistant Staphylococcus aureus (MRSA) and Enterobacteriaceae expressing extended-spectrum β-lactamases (ESBL-E). The decontamination process preceded the conversion from piglet breeding to gilt production. Microbiological surveillance showed that the decontamination measures eliminated the MRSA and ESBL-E strains that were detected on the farm before the complete removal of pigs, cleaning and disinfection of the stable, and construction of an additional stable meeting high-quality standards. After pig production was restarted, ESBL-E remained undetectable over 12 months, but MRSA was recovered from pigs and the environment within the first 2 days. However, spa (Staphylococcus aureus protein A gene) typing revealed acquisition of an MRSA strain (type t034) that had not been detected before decontamination. Interestingly, we observed that a farmworker who had been colonized with the prior MRSA strain (t2011) acquired the new strain (t034) after 2 months. In summary, this report demonstrates that decontamination protocols similar to those used here can lead to successful elimination of contaminating MRSA and ESBL-E in pigs and the stable environment. Nevertheless, decontamination protocols do not prevent the acquisition of new MRSA strains. PMID:26341200
Schmithausen, Ricarda Maria; Kellner, Sophia Ricarda; Schulze-Geisthoevel, Sophia Veronika; Hack, Sylvia; Engelhart, Steffen; Bodenstein, Isabel; Al-Sabti, Nahed; Reif, Marion; Fimmers, Rolf; Körber-Irrgang, Barbara; Harlizius, Jürgen; Hoerauf, Achim; Exner, Martin; Bierbaum, Gabriele; Petersen, Brigitte; Bekeredjian-Ding, Isabelle
2015-11-01
Colonization of livestock with bacteria resistant to antibiotics is considered a risk for the entry of drug-resistant pathogens into the food chain. For this reason, there is a need for novel concepts to address the eradication of drug-resistant commensals on farms. In the present report, we evaluated the decontamination measures taken on a farm contaminated with methicillin-resistant Staphylococcus aureus (MRSA) and Enterobacteriaceae expressing extended-spectrum β-lactamases (ESBL-E). The decontamination process preceded the conversion from piglet breeding to gilt production. Microbiological surveillance showed that the decontamination measures eliminated the MRSA and ESBL-E strains that were detected on the farm before the complete removal of pigs, cleaning and disinfection of the stable, and construction of an additional stable meeting high-quality standards. After pig production was restarted, ESBL-E remained undetectable over 12 months, but MRSA was recovered from pigs and the environment within the first 2 days. However, spa (Staphylococcus aureus protein A gene) typing revealed acquisition of an MRSA strain (type t034) that had not been detected before decontamination. Interestingly, we observed that a farmworker who had been colonized with the prior MRSA strain (t2011) acquired the new strain (t034) after 2 months. In summary, this report demonstrates that decontamination protocols similar to those used here can lead to successful elimination of contaminating MRSA and ESBL-E in pigs and the stable environment. Nevertheless, decontamination protocols do not prevent the acquisition of new MRSA strains. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
ETV REPORT: CERTEK, INC. 1414RH FORMALDEHYDE GENERATOR/NEUTRALIZER
The Environmental Technology Verification report discusses the technology and performance of the 1414RH Formaldehyde Generator/Neuralizer, a biological decontamination device manufactured by CERTEK, Inc. The unit was tested by evaluating its ability to decontaminate seven types ...
2010 US Environmental Protection Agency (EPA) ...
Report The U.S. Environmental Protection Agency (EPA) held the “2010 EPA Decontamination Research and Development Conference” to enable participants from throughout the world to discuss decontamination issues. In addition to the Plenary Session, the meeting addressed nine topic areas.
Transfer of radio-cesium from forest soil to woodchips using fungal activities
NASA Astrophysics Data System (ADS)
Kaneko, Nobuhiro; Huang, Yao; Tanaka, Yoichiro; Fujiwara, Yoshihiro; Sasaki, Michiko; Toda, Hiroto; Takahashi, Terumasa; Kobayashi, Tatsuaki; Harada, Naoki; Nonaka, Masahiro
2014-05-01
Raido-cesium released to terrestrial ecosystems by nuclear accidents is know to accumulate forest soil and organic layer on the soil. Forests in Japan are not exceptions. Practically it is impossible to decontaminate large area of forests. However, there is a strong demand from local people, who has been using secondary forests (Satoyama) around croplands in hilly areas, to decontaminate radio-cesium, because those people used to collect wild mushrooms and edible plants, and there are active cultures of mushrooms using logs and sawdusts. These natural resource uses consist substantial part of their economical activities, Therefore it is needed to decontaminate some selected part of forests in Japan to local economy. Clear cutting and scraping surface soil and organic matter are common methods of decontamination. However the efficiency of decontamination is up to 30% reduction of aerial radiation, and the cost to preserve contaminated debris is not affordable. In this study we used wood chips as a growth media for saprotrophic fungi which are known to accumulate redio-cesium. There are many studies indicated that mushrooms accumulated redio-cesium from forest soil and organic layer. It is not practical to collect mushrooms to decontaminate redio-cesium, because biomass of mushrooms are not enough to collect total contaminants. Mushrooms are only minor part of saprotrophic fungi. Fungal biomass in forest soil is about 1% of dead organic matter on forest floor. Our previous study to observe Cs accumulation to decomposing leaf litter indicated 18% absorption of total soil radio-Cs to litter during one year field incubation (Kaneko et al., 2013), and Cs concentration was proportional to fungal biomass on litter. This result indicated that fungi transferred radio-cesium around newly supplied leaf litter free of contamination. Therefore effective decontamination will be possible if we can provide large amount of growth media for saprotrophic fungi, and the media can be removed from forests with fungal bodies. We covered forest floor using wood chips, and observed Cs accumulation, and found that up to 50% of soil radio-cesium was transferred from soil to wood chips after 6-month of field incubation. Therefore this method is effective to decontaminate forest using ecological process. Kaneko N, Huang Y, Nakamori T, Tanaka Y, Nonaka M. Radio-cesium accumulation during decomposition of leaf litter in a deciduous forest after the Fukushima NPP accident. Geophysical Research Abstracts. 2013;15(EGU2013):7809.
Price, E; Weaver, G; Hoffman, P; Jones, M; Gilks, J; O'Brien, V; Ridgway, G
2016-03-01
A variety of methods are in use for decontaminating breast pump milk collection kits and related items associated with infant feeding. This paper aims to provide best practice guidance for decontamination of this equipment at home and in hospital. It has been compiled by a joint Working Group of the Healthcare Infection Society and the Infection Prevention Society. The guidance has been informed by a search of the literature in Medline, the British Nursing Index, the Cumulative Index to Nursing & Allied Health Literature, Midwifery & Infant Care and the results of two surveys of UK neonatal units in 2002/3 and 2006, and of members of the Infection Prevention Society in 2014. Since limited good quality evidence was available from these sources much of the guidance represents good practice based on the consensus view of the Working Group. Breast pump milk collection kits should not be reused by different mothers unless they have been sterilized in a Sterile Services Department between these different users.When used by the same mother, a detergent wash followed by thorough rinsing and drying after each use gives acceptable decontamination for most circumstances, as long as it is performed correctly.Additional decontamination precautions to washing, rinsing and drying may be used if indicated by local risk assessments and on advice from the departmental clinicians and Infection Prevention and Control Teams. The microbiological quality of the rinse water is an important consideration, particularly for infants on neonatal units.If bottle brushes or breast/nipple shields are used, they should be for use by one mother only. Decontamination should be by the processes used for breast pump milk collection kits.Dummies (soothers, pacifiers or comforters) needed for non-nutritive sucking by infants on neonatal units, should be for single infant use. Manufacturers should provide these dummies ready-to-use and individually packaged. They must be discarded at least every 24 hours or immediately if soiled with anything other than the baby's saliva. No attempt should be made to decontaminate the dummies, either before or during use. This guidance provides practical recommendations to support the safe decontamination of breast pump milk collection kits for healthcare professionals to use and communicate to other groups such as parents and carers.
Price, E; Weaver, G; Hoffman, P; Jones, M; Gilks, J; O’Brien, V; Ridgway, G
2015-01-01
Introduction: A variety of methods are in use for decontaminating breast pump milk collection kits and related items associated with infant feeding. This paper aims to provide best practice guidance for decontamination of this equipment at home and in hospital. It has been compiled by a joint Working Group of the Healthcare Infection Society and the Infection Prevention Society. Methods: The guidance has been informed by a search of the literature in Medline, the British Nursing Index, the Cumulative Index to Nursing & Allied Health Literature, Midwifery & Infant Care and the results of two surveys of UK neonatal units in 2002/3 and 2006, and of members of the Infection Prevention Society in 2014. Since limited good quality evidence was available from these sources much of the guidance represents good practice based on the consensus view of the Working Group. Key recommendations: Breast pump milk collection kits should not be reused by different mothers unless they have been sterilized in a Sterile Services Department between these different users. When used by the same mother, a detergent wash followed by thorough rinsing and drying after each use gives acceptable decontamination for most circumstances, as long as it is performed correctly. Additional decontamination precautions to washing, rinsing and drying may be used if indicated by local risk assessments and on advice from the departmental clinicians and Infection Prevention and Control Teams. The microbiological quality of the rinse water is an important consideration, particularly for infants on neonatal units. If bottle brushes or breast/nipple shields are used, they should be for use by one mother only. Decontamination should be by the processes used for breast pump milk collection kits. Dummies (soothers, pacifiers or comforters) needed for non-nutritive sucking by infants on neonatal units, should be for single infant use. Manufacturers should provide these dummies ready-to-use and individually packaged. They must be discarded at least every 24 hours or immediately if soiled with anything other than the baby’s saliva. No attempt should be made to decontaminate the dummies, either before or during use. Conclusion: This guidance provides practical recommendations to support the safe decontamination of breast pump milk collection kits for healthcare professionals to use and communicate to other groups such as parents and carers. PMID:28989455
Hidaka, Tomoo; Kakamu, Takeyasu; Hayakawa, Takehito; Kumagai, Tomohiro; Jinnouchi, Takanobu; Sato, Sei; Tsuji, Masayoshi; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2016-01-01
Objectives: To reveal the effect of age and other factors on perceived anxiety over radiation exposure among decontamination workers in Fukushima Prefecture, Japan. Methods: A survey questionnaire was sent to 1505 workers, with questions regarding age, presence of a written employment contract, previous residence, radiation passbook ownership, presence of close persons for consultation, knowledge of how to access public assistance, and a four-point scale of radiation-related anxiety (1= "Very much," 2= "Somewhat," 3= "A little bit," and 4= "None" ). The relationships between the degree of anxiety and variables were analyzed using the chi-square test and residual analysis. Results: In all, 512 participants responded to the questionnaire. The mean age of participants was 46.2 years (SD: 13.1, range: 18-77). Of them, 50, 233, 168, and 61 workers chose "Very much," "Somewhat," "A little bit," and "None," respectively, on the anxiety scale. Chi-square test showed that participants aged 61 years and over had higher degrees of anxiety (p<0.001). Ordinal logistic regression showed that the degree of anxiety increased if they did not have a written contract (p=0.042) or persons to consult (p=0.034) and if they routinely checked the dose rate (p=0.046). Conclusions: Decontamination workers who do not have a written contract or who are in socially isolated situations have greater anxiety over radiation exposure. Thus, it is important to both create supportive human relationships for consultation and enhance labor management in individual companies. PMID:27010088
del Río, Elena; González de Caso, Beatriz; Prieto, Miguel; Alonso-Calleja, Carlos; Capita, Rosa
2008-10-01
Various chemical compounds are currently under review for final approval as poultry decontaminants in the European Union (EU). Concentration is among the factors considered by the EU authorities in the evaluation of these treatments. The aim of this research was to compare the growth parameters for pathogenic and spoilage bacteria in presence of high and low concentrations of poultry decontaminants to assess whether such treatments could involve a potential sanitary risk for consumers. Growth curves for Salmonella enterica serotype Enteritidis, Listeria monocytogenes, Pseudomonas fluorescens and Brochothrix thermosphacta were obtained at different levels of trisodium phosphate (TSP; 1.74%; 0.58%), acidified sodium chlorite (ASC; 210 ppm; 70 ppm) and citric acid (CA; 0.27%; 0.09%). The modified Gompertz equation was used as primary model to fit observed data. ASC and TSP were the most effective compounds in increasing lag phase (L) and reducing maximum growth rate (mu) in Gram-negative bacteria. Gram-positive bacteria were more influenced by CA. At high TSP levels, mu for Salmonella decreased. Low TSP levels increased mu for Salmonella and Listeria relative to control samples. In presence of 0.27% CA, Brochothrix showed the highest L and the lowest mu among strains tested. These results suggest that low TSP and high CA concentrations could favour the outgrowth of pathogenic bacteria (e.g. Salmonella) relative to spoilage bacteria, rending these treatments potentially dangerous for consumers. The findings of this study may be useful to the EU authorities and meat processors in their efforts to select adequate treatments for control of bacteria on poultry.
Code of Federal Regulations, 2014 CFR
2014-01-01
... ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF... account in the U.S. Treasury referred to as the Uranium Enrichment Decontamination and Decommissioning... separative work unit, the common measure by which uranium enrichment services are sold. TESS means the Toll...
Code of Federal Regulations, 2012 CFR
2012-01-01
... ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF... account in the U.S. Treasury referred to as the Uranium Enrichment Decontamination and Decommissioning... separative work unit, the common measure by which uranium enrichment services are sold. TESS means the Toll...
Code of Federal Regulations, 2013 CFR
2013-01-01
... ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF... account in the U.S. Treasury referred to as the Uranium Enrichment Decontamination and Decommissioning... separative work unit, the common measure by which uranium enrichment services are sold. TESS means the Toll...
Code of Federal Regulations, 2011 CFR
2011-01-01
... ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF... account in the U.S. Treasury referred to as the Uranium Enrichment Decontamination and Decommissioning... separative work unit, the common measure by which uranium enrichment services are sold. TESS means the Toll...
This document is a report describing the assessment of seven alternative treatment processes that show potential for decontaminating polychlorinated biphenyl (PCB)-contaminated sediments. The processes are KPEG, MODAR Supercritical Water Oxidation, Bio-Clean, Ultrasonics/UV, C...
48 CFR 1523.303-71 - Decontamination of Government-furnished property.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Decontamination of Government-furnished property. 1523.303-71 Section 1523.303-71 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY SOCIOECONOMIC PROGRAMS ENVIRONMENTAL, CONSERVATION, OCCUPATIONAL SAFETY, AND...
COMPILATION OF AVAILABLE DATA ON BUILDING DECONTAMINATION ALTERNATIVES
The report presents an analysis of selected technologies that have been tested for their potential effectiveness in decontaminating a building that has been attacked using biological or chemical warfare agents, or using toxic industrial compounds. The technologies selected to be ...
78 FR 48428 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
... program are General Dynamics Land System of Sterling Heights, Michigan; Karcher Futuretech of Schwailheim... Chemical Reconnaissance Vehicles, DECON 3000 Decontamination Systems, M26 Commercial Joint Service Transportable Decontamination Systems (JSTDS), AN/VRC-89 Single Channel Ground and Airborne Radio Systems...
Decontamination of Bacillus spores adhered to iron and ...
Journal Article This study examines the effectiveness of decontaminating Bacillus globigii spores attached to corroded iron and cement-mortar coupons with free chlorine at two pH levels, monochloramine, chlorine dioxide, ozone, peracetic acid (PAA) and acidified nitrite, followed by flushing.
DECONTAMINATION OF STRUCTURES AND DEBRIS AT SUPERFUND SITES
Two building decontamination technologies were demonstrated and evaluated: a method for in situ degradation of PCB's requiring application of an alkali metal/polyethylene glycolate mixture directly on concrete surfaces; and a shotblasting technique using steel shot to cut away co...
Concrete decontamination by Electro-Hydraulic Scabbling (EHS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-11-01
EHS is being developed for decontaminating concrete structures from radionuclides, organic substances, and hazardous metals. EHS involves the generation of powerful shock waves and intense cavitation by a strong pulsed electric discharge in a water layer at the concrete surface; high impulse pressure results in stresses which crack and peel off a concrete layer of controllable thickness. Scabbling produces contaminated debris of relatively small volume which can be easily removed, leaving clean bulk concrete. Objective of Phase I was to prove the technical feasibility of EH for controlled scabbling and decontamination of concrete. Phase I is complete.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
This report documents the second phase of the Remote Operated Vehicle with CO{sub 2} Blasting (ROVCO{sub 2}) Program. The ROVCO{sub 2} Program`s goal is to develop and demonstrate a tool to improve the productivity of concrete floor decontamination. The second phase integrated non-developmental subsystems on to the ROVCO{sub 2} system and performed quantitative decontamination effectiveness, productivity, and reliability testings. The report documents these development activities and the analysis of cost and performance. The results show that the ROVCO{sub 2} system is an efficient decontamination tool.
Cold plasma decontamination using flexible jet arrays
NASA Astrophysics Data System (ADS)
Konesky, Gregory
2010-04-01
Arrays of atmospheric discharge cold plasma jets have been used to decontaminate surfaces of a wide range of microorganisms quickly, yet not damage that surface. Its effectiveness in decomposing simulated chemical warfare agents has also been demonstrated, and may also find use in assisting in the cleanup of radiological weapons. Large area jet arrays, with short dwell times, are necessary for practical applications. Realistic situations will also require jet arrays that are flexible to adapt to contoured or irregular surfaces. Various large area jet array prototypes, both planar and flexible, are described, as is the application to atmospheric decontamination.
Decontamination of 2-chloroethyl ethylsulfide using titanate nanoscrolls
NASA Astrophysics Data System (ADS)
Kleinhammes, Alfred; Wagner, George W.; Kulkarni, Harsha; Jia, Yuanyuan; Zhang, Qi; Qin, Lu-Chang; Wu, Yue
2005-08-01
Titanate nanoscrolls, a recently discovered variant of TiO 2 nanocrystals, are tested as reactive sorbent for chemical warfare agent (CWA) decontamination. The large surface area of the uncapped tubules provides the desired rapid absorption of the contaminant while water molecules, intrinsic constituents of titanate nanoscrolls, provide the necessary chemistry for hydrolytic reaction. In this study the decomposition of 2-chloroethyl ethylsulfide (CEES), a simulant for the CWA mustard, was monitored using 13C NMR. The NMR spectra reveal reaction products as expected from the hydrolysis of CEES. This demonstrates that titanate nanoscrolls could potentially be employed as a decontaminant for CWAs.
A comparative study for radiological decontamination of laboratory fume hood materials.
Thomas, Elizabeth; Sweet, Lucas; MacFarlan, Paul; McNamara, Bruce; Kerschner, Harrison
2012-08-01
The efficacy for radiological decontamination of the laboratory standard fume hood as constructed of stainless steel, compared to that of powder-coated carbon steel is described. While the chemical inertness of powder-coated surfaces is good, faced with everyday abrasion, aggressive inorganic solutions and vapors, and penetrating organics commonly employed in government laboratory fume hoods, radiological decontamination of powder-coated steel surfaces was found to be similar to those made of stainless steel for easily solubilized or digestible radionuclides. Plutonium was difficult to remove from stainless steel and powder-coated surfaces, especially after prolonged contact times.
1988-11-01
results. On the contrary, the active decon moiety in both cases is the hydroxyl ion (0OH), and the agent being decontaminated reacts exactly the same...methods. A review of method3 utilized to determine the concentration of active material before and after the decontamination process. Included are the most...isolation of acid A, acid B will probably be excluded by the forces active in the crystallization process. Acid B will therefore be missed in the overall
Development of Personal Decontamination System Final Report CRADA No. TC-02078-04
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, W. J.; O'Dell, P.
2017-09-27
This was a collaborative effort between The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL) and O’Dell Engineering, Ltd. (O’Dell) to develop an improved low-cost personal decontamination system for Toxic Industrial Chemicals (TICs) and chemical agents. The significant change to the project was that COTS (Commercial Off-the Shelf Components) were identified that performed as well, or better than, the proprietary materials created and tested as part of this CRADA. These COTS components were combined to create a new LPDS (low-cost personal decontamination system) that met all specifications.
Buhr, T L; Young, A A; Barnette, H K; Minter, Z A; Kennihan, N L; Johnson, C A; Bohmke, M D; DePaola, M; Cora-Laó, M; Page, M A
2015-11-01
To develop test methods and evaluate survival of Bacillus anthracis ∆Sterne or Bacillus thuringiensis Al Hakam on materials contaminated with dirty spore preparations after exposure to hot, humid air using response surface modelling. Spores (>7 log10 ) were mixed with humic acid + spent sporulation medium (organic debris) or kaolin (dirt debris). Spore samples were then dried on five different test materials (wiring insulation, aircraft performance coating, anti-skid, polypropylene, and nylon). Inoculated materials were tested with 19 test combinations of temperature (55, 65, 75°C), relative humidity (70, 80, 90%) and time (1, 2, 3 days). The slowest spore inactivation kinetics was on nylon webbing and/or after addition of organic debris. Hot, humid air effectively decontaminates materials contaminated with dirty Bacillus spore preparations; debris and material interactions create complex decontamination kinetic patterns; and B. thuringiensis Al Hakam is a realistic surrogate for B. anthracis. Response surface models of hot, humid air decontamination were developed which may be used to select decontamination parameters for contamination scenarios including aircraft. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Lydon, Helen L; Hall, Charlotte A; Dalton, Christopher H; Chipman, J Kevin; Graham, John S; Chilcott, Robert P
2017-08-01
Previous studies have demonstrated that haemostatic products with an absorptive mechanism of action retain their clotting efficiency in the presence of toxic materials and are effective in decontaminating chemical warfare (CW) agents when applied to normal, intact skin. The purpose of this in vitro study was to assess three candidate haemostatic products for effectiveness in the decontamination of superficially damaged porcine skin exposed to the radiolabelled CW agents, soman (GD), VX and sulphur mustard (HD). Controlled physical damage (removal of the upper 100 μm skin layer) resulted in a significant enhancement of the dermal absorption of all three CW agents. Of the haemostatic products assessed, WoundStat™ was consistently the most effective, being equivalent in performance to a standard military decontaminant (fuller's earth). These data suggest that judicious application of haemostatic products to wounds contaminated with CW agents may be a viable option for the clinical management of casualties presenting with contaminated, haemorrhaging injuries. Further studies using a relevant animal model are required to confirm the potential clinical efficacy of WoundStat™ for treating wounds contaminated with CW agents. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
A decontamination study of simulated chemical and biological agents
NASA Astrophysics Data System (ADS)
Uhm, Han S.; Lee, Han Y.; Hong, Yong C.; Shin, Dong H.; Park, Yun H.; Hong, Yi F.; Lee, Chong K.
2007-07-01
A comprehensive decontamination scheme of the chemical and biological agents, including airborne agents and surface contaminating agents, is presented. When a chemical and biological attack occurs, it is critical to decontaminate facilities or equipments to an acceptable level in a very short time. The plasma flame presented here may provide a rapid and effective elimination of toxic substances in the interior air in isolated spaces. As an example, a reaction chamber, with the dimensions of a 22cm diameter and 30cm length, purifies air with an airflow rate of 5000l/min contaminated with toluene, the simulated chemical agent, and soot from a diesel engine, the simulated aerosol for biological agents. Although the airborne agents in an isolated space are eliminated to an acceptable level by the plasma flame, the decontamination of the chemical and biological agents cannot be completed without cleaning surfaces of the facilities. A simulated sterilization study of micro-organisms was carried out using the electrolyzed ozone water. The electrolyzed ozone water very effectively kills endospores of Bacillus atrophaeus (ATCC 9372) within 3min. The electrolyzed ozone water also kills the vegetative micro-organisms, fungi, and virus. The electrolyzed ozone water, after the decontamination process, disintegrates into ordinary water and oxygen without any trace of harmful materials to the environment.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of radiological agents on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some important radiological agents (cesium, strontium and cobalt), but important data gaps remain. Although some targeted experiments have been published on cesium, strontium and cobalt persistence on drinking water infrastructure, most of the data comes from nuclear clean-up sites. Furthermore, the studies focused on drinking water systems use non-radioactive surrogates. Non-radioactive cobalt was shown to be persistent on iron due to oxidation with free chlorine in drinking water and precipitation on the iron surface. Decontamination with acidification was an effective removal method. Strontium persistence on iron was transient in tap water, but adherence to cement-mortar has been demonstrated and should be further explored. Cesium persistence on iron water infrastructure was observed when flow was stagnant, but not with water flow present. Future research suggestions focus on expanding the available cesium, strontium and cobalt persistence data to other common infrastructure materials, specifically cement-mortar. Further exploration chelating agents and low pH treatment is recommended for future decontamination studies. Published by Elsevier Ltd.
Calfee, M W; Wendling, M
2015-11-01
Five commercially available liquid antimicrobials were evaluated for their ability to decontaminate common environmental surface materials, contaminated with Burkholderia pseudomallei, using a spray-based disinfectant delivery procedure. Tests were conducted at both an ambient temperature (c. 20°C) and a lower temperature (c. 12°C) condition. Nonporous materials (glass and aluminium) were more easily decontaminated than porous materials (wood, concrete and carpet). Citric acid (1%) demonstrated poor efficacy in all test conditions. Bleach (pH-adjusted), ethanol (70%), quaternary ammonium and PineSol®, demonstrated high (>6 log10 reduction) efficacies on glass and aluminium at both temperatures, but achieved varying results for wood, carpet and concrete. Temperature had minimal effect on decontamination efficacy during these tests. Much of the antimicrobial efficacy data for pathogenic micro-organisms are generated with testing that utilizes hard nonporous surface materials. These data are not directly translatable for decontaminant selection following an incident whereby complex and porous environmental surfaces are contaminated. This study presents efficacy data for spray-applied antimicrobial liquids, when used to decontaminate common environmental surfaces contaminated with Burkholderia pseudomallei. These data can help responders develop effective remediation strategies following an environmental contamination incident involving B. pseudomallei. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Lumia, Margaret E.; Gentile, Charles; Gochfeld, Michael; Efthimion, Philip; Robson, Mark
2015-01-01
This study evaluates a new decontamination technique for the mitigation and abatement of hazardous particulates. The traditional decontamination methods used to clean facilities and equipment are time-consuming, prolonging workers' exposure time, may generate airborne hazards, and can be expensive. The use of removable thin film coating as a decontamination technique for surface contamination proved to be a more efficient method of decontamination. This method was tested at three different sites on different hazardous metals. One application of the coating reduced the levels of these metals 90% and had an average reduction of one magnitude. The paired t-tests that were performed for each metal demonstrated that there was a statistically significant reduction of the metal after the use of the coating: lead (p = 0.03), beryllium (p = 0.05), aluminum (p = 0.006), iron (p = 0.0001), and copper (p = 0.004). The Kendall tau-b correlation coefficient demonstrates that there was a positive correlation between the initial levels of contamination and the removal efficiency for all the samples taken from different locations on the floor for each of the three sites. This new decontamination technique worked efficiently, requiring only one application, which decreased exposure time and did not generate any airborne dust. PMID:19437305
DEVELOPMENT OF ELECTRO-ACOUSTIC SOIL DECONTAMINATION (ESD) FOR IN-SITU APPLICATIONS
The technical feasibility of electro-acoustic soil decontamination process through lab experiments demonstrated the removal/-concentration of heavy metals such as cadmium and zinc. Results of the decane contaminated soils were, however, inconclusive. The ESD process is based on t...
Decontaminating metal surfaces
Childs, E.L.
1984-01-23
Radioactively contaminated surfaces can be electrolytically decontaminated with greatly increased efficiencies by using electrolytes containing higher than heretofore conventional amounts of nitrate, e.g., >600 g/1 of NaNO/sub 3/, or by using nitrate-containing electrolytes which are acidic, e.g., of a pH < 6.
The Environmental Technology Verification report discusses the technology and performance of the Clarus C Hydrogen Peroxide Gas Generator, a biological decontamination device manufactured by BIOQUELL, Inc. The unit was tested by evaluating its ability to decontaminate seven types...
Decontaminating metal surfaces
Childs, Everett L.
1984-11-06
Radioactively contaminated surfaces can be electrolytically decontaminated with greatly increased efficiencies by using electrolytes containing higher than heretofore conventional amounts of nitrate, e.g.,>600 g/l of NaNO.sub.3, or by using nitrate-containing electrolytes which are acidic, e.g., of a pH<6.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Purpose. 766.1 Section 766.1 Energy DEPARTMENT OF ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF DOMESTIC... Assessment of domestic utilities for the Uranium Enrichment Decontamination and Decommissioning Fund pursuant...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Purpose. 766.1 Section 766.1 Energy DEPARTMENT OF ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF DOMESTIC... Assessment of domestic utilities for the Uranium Enrichment Decontamination and Decommissioning Fund pursuant...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Purpose. 766.1 Section 766.1 Energy DEPARTMENT OF ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF DOMESTIC... Assessment of domestic utilities for the Uranium Enrichment Decontamination and Decommissioning Fund pursuant...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Purpose. 766.1 Section 766.1 Energy DEPARTMENT OF ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF DOMESTIC... Assessment of domestic utilities for the Uranium Enrichment Decontamination and Decommissioning Fund pursuant...
CATALYTIC ENZYME-BASED METHODS FOR WATER TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION
Current chemistry-based decontaminants for chemical or biological warfare agents and related toxic materials are caustic and have the potential for causing material and environmental damage. In addition, most are bulk liquids that require significant logistics and storage capabil...
Szabo, Jeffrey G; Muhammad, Nur; Heckman, Lee; Rice, Eugene W; Hall, John
2012-04-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone.
VERIFICATION OF THE PERFORMANCE OF DECONTAMINATION TECHNOLOGIES IN EPA'S SAFE BUILDINGS PROGRAM
The paper describes initial progress in identifying and testing technologies applicable for decontaminating workplaces and other buildings that may be subject to chemical or biological attack. The EPA is using the process established in its Environmental Technology Verification (...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Purpose. 766.1 Section 766.1 Energy DEPARTMENT OF ENERGY URANIUM ENRICHMENT DECONTAMINATION AND DECOMMISSIONING FUND; PROCEDURES FOR SPECIAL ASSESSMENT OF DOMESTIC... Assessment of domestic utilities for the Uranium Enrichment Decontamination and Decommissioning Fund pursuant...
Minimal impact, waterless decontamination technologies for improving food safety
USDA-ARS?s Scientific Manuscript database
Pathogen contamination of produce, meats, poultry, shellfish, and other foods remains an ongoing concern. Chemical sanitizers are widely employed for foods and food contact surfaces. However, there is growing interest in the development of minimal impact, waterless decontamination processes that wil...
Mastracchio installs MSG LSAH Decontamination System
2014-02-10
ISS038-E-044829 (10 Feb. 2014) --- NASA astronaut Rick Mastracchio, Expedition 38 flight engineer, prepares to use an ultraviolet light to decontaminate hardware used for life science experiments inside the Microgravity Science Glovebox (MSG) in the Destiny laboratory of the International Space Station.
Expedient Approaches for the Management of Wastes ...
Report The current study sought to determine waste decontamination conditions that would achieve complete kill for all material types. For these tests, more stringent decontamination procedures were evaluated specifically using pAB amended with a surfactant and/or waste submersion procedures involving agitation.
Lydon, Helen; Hall, Charlotte; Matar, Hazem; Dalton, Christopher; Chipman, J Kevin; Graham, John S; Chilcott, Robert P
2018-03-01
This study used a damaged skin, porcine model to evaluate the in vivo efficacy of WoundStat™ for the decontamination of superficial, nerve agent-contaminated wounds. Anaesthetized animals were randomly assigned to either control (n = 7), no decontamination (n = 12) or WoundStat™ (n = 12) treatment groups. Pigs were exposed to a 5× LD 50 dose of neat, radiolabelled S-[2-(diisopropylamino)ethyl]-O-ethyl methyl-phosphonothioate (VX; or equivalent volume of sterile saline for the control group) via an area of superficially damaged skin on the ear. WoundStat™ was applied at 30 seconds post-exposure to assigned animals. The VX contaminant (or saline) and decontaminant remained in place for the duration of the study (up to 6 hours). Physiological parameters and signs of intoxication were recorded during the exposure period. Skin and organ samples were taken post mortem for 14 C-VX distribution analyses. Blood samples were taken periodically for toxicokinetic and whole-blood acetylcholinesterase (AChE) activity analyses. VX exposure was accompanied by a rapid decrease in AChE activity in all animals, regardless of decontamination. However, decontamination significantly improved survival rate and time and reduced the severity of signs of intoxication. In addition, the distribution of 14 C-VX in key internal organs and post mortem blood samples was significantly lower in the WoundStat™ treatment group. This study demonstrates that WoundStat™ may be a suitable medical countermeasure for increasing both survival rate and time following VX exposure. The results also suggest that AChE activity is not a useful prognostic indicator. Copyright © 2017 John Wiley & Sons, Ltd.
Koff, Matthew D; Brown, Jeremiah R; Marshall, Emily J; O'Malley, A James; Jensen, Jens T; Heard, Stephen O; Longtine, Karen; O'Neill, Melissa; Longtine, Jaclyn; Houston, Donna; Robison, Cindy; Moulton, Eric; Patel, Hetal M; Loftus, Randy W
2016-08-01
BACKGROUND Healthcare provider hands are an important source of intraoperative bacterial transmission events associated with postoperative infection development. OBJECTIVE To explore the efficacy of a novel hand hygiene improvement system leveraging provider proximity and individual and group performance feedback in reducing 30-day postoperative healthcare-associated infections via increased provider hourly hand decontamination events. DESIGN Randomized, prospective study. SETTING Dartmouth-Hitchcock Medical Center in New Hampshire and UMass Memorial Medical Center in Massachusetts. PATIENTS Patients undergoing surgery. METHODS Operating room environments were randomly assigned to usual intraoperative hand hygiene or to a personalized, body-worn hand hygiene system. Anesthesia and circulating nurse provider hourly hand decontamination events were continuously monitored and reported. All patients were followed prospectively for the development of 30-day postoperative healthcare-associated infections. RESULTS A total of 3,256 operating room environments and patients (1,620 control and 1,636 treatment) were enrolled. The mean (SD) provider hand decontamination event rate achieved was 4.3 (2.9) events per hour, an approximate 8-fold increase in hand decontamination events above that of conventional wall-mounted devices (0.57 events/hour); P<.001. Use of the hand hygiene system was not associated with a reduction in healthcare-associated infections (odds ratio, 1.07 [95% CI, 0.82-1.40], P=.626). CONCLUSIONS The hand hygiene system evaluated in this study increased the frequency of hand decontamination events without reducing 30-day postoperative healthcare-associated infections. Future work is indicated to optimize the efficacy of this hand hygiene improvement strategy. Infect Control Hosp Epidemiol 2016;37:888-895.
Microbial flora on cell-phones in an orthopedic surgery room before and after decontamination.
Murgier, J; Coste, J-F; Cavaignac, E; Bayle-Iniguez, X; Chiron, P; Bonnevialle, P; Laffosse, J-M
2016-12-01
Cell-phones are the typical kind of object brought into the operating room from outside by hospital staff. A great effort is made to reduce the level of potentially contaminating bacteria in the operating room, and introducing these devices may run counter to good practice. The study hypothesis was that cell-phones are colonized by several strains of bacteria and may constitute a source of nosocomial contamination. The main study objective was to screen for bacterial colonies on the surfaces of cell-phones introduced in an orthopedic surgery room. The secondary objective was to assess the efficacy of decontamination. Samples were taken from the cell-phones of hospital staff (surgeons, anaesthetists, nurses, radiology operators, and external medical representatives) entering the operating room of the university hospital center orthopedic surgery department, Toulouse (France). Sampling used Count Tact ® contact gel, without wiping the phone down in advance. Both sides of the phone were sampled, before and after decontamination with a pad imbibed with 0.25% Surfanios ® Premium disinfectant. A nasal sample was also taken to investigate the correlation between Staphylococcus aureus in the nasal cavities and on the cell-phone. Fifty-two cell-phones were sampled. Before decontamination, the mean number of colony-forming units (CFU) was 258 per phone (range, 0-1,664). After decontamination, it was 127 (range, 0-800) (P=0.0001). Forty-nine cell-phones bore CFUs before decontamination (94%), and 39 after (75%) (P=0.02). Cell-phones are CFU carriers and may thus lead to contamination. Guidelines should be drawn up to encourage cleaning phones regularly and to reduce levels of use within the operating room. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
de Waal, Y C M; Raghoebar, G M; Meijer, H J A; Winkel, E G; van Winkelhoff, A J
2015-09-01
The objective of this randomized, double-blind, controlled trial was to evaluate the clinical, radiographic, and microbiological effects of implant surface decontamination with a 2% chlorhexidine (CHX) solution in comparison with a 0.12% chlorhexidine + 0.05% cetylpyridinium chloride (CPC) solution during resective surgical peri-implantitis treatment. Forty-four patients (108 implants) with peri-implantitis were treated with resective surgical treatment consisting of bone re-contouring, surface debridement and chemical decontamination, and apically repositioned flap. Patients were randomly allocated to decontamination with a 2% CHX solution (test group) or 0.12% CHX + 0.05% CPC (control group). Clinical and radiographic parameters were recorded before treatment (baseline), and at 3, 6, and 12 months after treatment. Microbiological parameters were recorded during surgery. Multilevel analysis showed no significant differences in bleeding, suppuration, probing pocket depth, and radiographic bone loss between control and test group over three follow-up measurements (3, 6, and 12 months) from baseline. Both decontamination procedures resulted in significant reductions in anaerobic bacterial counts on the implant surface, but no significant difference was noted between control and test group (mean log 3.37 ± 2.34 vs. 3.65 ± 2.87, P = 0.99). The use of a 2% CHX solution for implant surface decontamination during resective peri-implantitis therapy does not lead to improved clinical, radiographic, or microbiological results compared with a 0.12% CHX + 0.05% CPC solution. Overall, the additional use of CHX reduces anaerobic bacterial load on the implant surface better than mechanical debridement alone, but does not seem to enhance clinical treatment outcomes (ClinicalTrials.gov number NCT01852253). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cao, Yachao; Elmahdy, Akram; Zhu, Hanjiang; Hui, Xiaoying; Maibach, Howard
2018-05-01
Six chemical warfare agent simulants (trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate) were studied in in vitro human skin to explore relationship between dermal penetration/absorption and the mechanisms of simulant partitioning between stratum corneum (SC) and water as well as between dermal decontamination gel (DDGel) and water. Both binding affinity to and decontamination of simulants using DDGel were studied. Partition coefficients of six simulants between SC and water (Log P SC/w ) and between DDGel and water (Log P DDGel/w ) were determined. Results showed that DDGel has a similar or higher binding affinity to each simulant compared to SC. The relationship between Log P octanol/water and Log P SC/w as well as between Log P octanol/water and Log P DDGel/w demonstrated that partition coefficient of simulants correlated to their lipophilicity or hydrophilicity. Decontamination efficiency results with DDGel for these simulants were consistent with binding affinity results. Amounts of percentage dose of chemicals in DDGel of trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate were determined to be 61.15, 85.67, 75.91, 53.53, 89.89 and 76.58, with corresponding amounts absorbed in skin of 0.96, 0.65, 1.68, 0.72, 0.57 and 1.38, respectively. In vitro skin decontamination experiments coupled with a dermal absorption study demonstrated that DDGel can efficiently remove chemicals from skin surface, back-extract from the SC, and significantly reduced chemical penetration into skin or systemic absorption for all six simulants tested. Therefore, DDGel offers a great potential as a NextGen skin Decon platform technology for both military and civilian use. Copyright © 2018 John Wiley & Sons, Ltd.
An evaluation of selected methods for the decontamination of cattle hides prior to skinning.
Small, A; Wells-Burr, B; Buncic, S
2005-02-01
The effectiveness of different decontamination treatments in reducing microbial loads on cattle hides was assessed. The 10-s hide treatments were conducted using a wet-and-dry vacuum cleaner filled with one of the liquids (heated to 50 °C) indicated below, followed or not by 10-min drying in the air. Also, the hide was clipped, followed or not by 10-s singeing using a hand-held blowtorch. Before and after each decontamination treatment, the hide was sampled (100 cm(2) areas) by a sponge-swabbing method to compare the total viable counts of bacteria (TVC). The largest bacterial reduction (P<0.001; 2.31log(10) cfu/cm(2)) was achieved by singeing of previously clipped hide. Treatment of hide with a food industry sanitizer solution (10% Betane Plus) resulted in significant reductions of 1.80 (P<0.001) and 1.98log(10) cfu/cm(2) (P<0.001) without and with subsequent drying, respectively. Treatment of hide with a food industry disinfectant (P3-Topactive DES) significantly reduced TVC by 0.97 (P<0.001) and 1.18log(10) cfu/cm(2) (P<0.001) without and with subsequent drying, respectively. Treatments of hide with water alone or with a food-safe detergent solution (Formula 963B), or hide clipping alone, did not produce significant decontamination effects. Since hide contamination is associated with microbial contamination of the carcasses, the results indicate that post-killing/pre-skinning hide decontamination (used alone, or in combination with carcass decontamination) has a potential to improve microbial meat safety. Nevertheless, further research is required to optimise the efficacy of these treatments in the reduction of specific pathogens under commercial conditions.
Facilities for chemical decontamination in accident and emergency departments in the United Kingdom
George, G; Ramsay, K; Rochester, M; Seah, R; Spencer, H; Vijayasankar, D; Vasicuro, L
2002-01-01
Objective: To audit the facilities for chemical decontamination, with special reference to cyanide poisoning, in all major accident and emergency departments in the UK. Method: A simple postal questionnaire was used to audit planning, premises, equipment, protection for staff, and stocks of specific antidotes to cyanide poisoning. Results: 227 questionnaires from 261 departments (87%) were returned and used in the survey. Of the 227 departments who responded, 151 (66%) had a written plan; 168 (74%) departments had premises for decontamination; 55 (24%) were judged to have satisfactory premises; 146 (64%) departments had a shower or hose for decontamination; 60 (26%) departments had a decontamination trolley suitable for "stretcher" patients; 203 (89%) had some protective equipment for staff but only 77 (34%) had complete protection—that is, goggles, chemical resistant clothing, and breathing apparatus. In the authors' opinion only seven (3%) departments had satisfactory premises and equipment to treat "stretcher" patients and full protection for staff. A further 11 (5%) departments were equipped to manage ambulant patients at a similar level. Some 205 (90%) departments stocked one or more antidotes to cyanide and 77 (34%) stocked all four antidotes. Thirty four (15%) departments held all four antidotes to cyanide and had full protection for staff. Only five (2%) departments had satisfactory premises and equipment to treat "stretcher" patients, full protection for staff, and at least three of four antidotes. Conclusions: Most departments had some equipment for chemical decontamination. However, there were major inconsistencies in the range of equipment held and these limited its usefulness. Only a small minority of departments was satisfactorily equipped to deal with a serious chemical incident. PMID:12205006
2015-06-01
California EMSA, National Incident Management System, NIMS, hospital preparedness program, Nursing Home Incident Command System, NHICS, Hospital...The International Journal of Trauma Nursing published an article in 2007 entitled “Organization of a Hospital-based Victim Decontamination Plan...Journal of Trauma Nursing 5, no. 4 (October– November 2007): 119–123. 32 Ellen Lanser May, “Scarred but Smarter: Lessons Learned from Florida’s 2004
Production and separation of carrier-free 7Be
Gharibyan, N.; Moody, K. J.; Tumey, S. J.; ...
2015-10-24
A high-purity carrier-free 7Be was efficiently isolated following proton bombardment of a lithium hydroxide - aluminum target. The separation of beryllium from lithium and aluminum was achieved through a hydrochloric acid elution system utilizing cation exchange chromatography. The beryllium recovery, +99%, was assessed through gamma spectroscopy while the chemical purity was established by mass spectrometry. In conclusion, the decontamination factors of beryllium from lithium and aluminum were determined to be 6900 and 300, respectively.
1990-10-01
involving a heavy artillery barrage, the impact point output alone could consume upwards of 10,000 pages of computer paper. For this reason, AURA provides...but pervasive factor: the asset allocation model must be compatible with the mathematical behavior of the input data. Thus, for example, if assets are...described as expendable during repair or decontamination activities, it must have HOMELINKS which appear in the consuming repair SUBCHAINs
Symposium on the reprocessing of irradiated fuels. Book 2, Session IV
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1958-12-31
Book two of this conference has a single-focused session IV entitled Nonaqueous Processing, with 8 papers. The session deals with fluoride volatility processes and pyrometallurgical or pyrochemical processes. The latter involves either an oxide drossing or molten metal extraction or fused salt extraction technique and results in only partial decontamination. Fluoride volatility processes appear to be especially favorable for recovery of enriched uranium and decontamination factors of 10/sup 7/ to 10/sup 8/ would be achieved by simpler means than those employed in solvent extraction. Data from lab research on the BrF/sub 3/ process and the ClF/sub 3/ process are givenmore » and discussed and pilot plant experience is described, all in connection with natural uranium or slightly enriched uranium processing. Fluoride volatility processes for enriched or high alloy fuels are described step by step. The economic and engineering considerations of both types of nonaqueous processing are treated separately and as fully as present knowledge allows. A comprehensive review of the chemistry of pyrometallurgical processes is included.« less
Veelo, Denise P; Bulut, Tomas; Dongelmans, Dave A; Korevaar, Johanna C; Spronk, Peter E; Schultz, Marcus J
2008-01-01
Tracheotomy is considered to be an independent risk factor for ventilator-associated pneumonia (VAP). Antimicrobial prophylaxis, in particular with coverage of Pseudomonas aeruginosa, is presently advocated. Selective decontamination of the digestive tract (SDD) aims to prevent VAP in critically ill patients, including those after tracheotomy. We determined the incidence and microbial spectrum of VAP after tracheotomy in a SDD-setting. Retrospective analysis of 231 tracheotomized patients during a 2-year period. Thirteen patients (5.6%) developed VAP. The median [IQR] day of onset was 8.0 [3.0-10.5] days after tracheotomy. The most predominant causative pathogen was Methicillin-sensitive Staphylococcus aureus (MSSA). Timing of tracheotomy was not different between patients developing VAP and those who did not. The type of tracheotomy (percutaneous or surgical, 84.6% versus 15.4%) had no significant influence on the incidence of VAP. The incidence of VAP after tracheotomy in a SDD-setting is low, with MSSA as the predominant causative pathogen. Accordingly, if antimicrobial prophylaxis is considered, it may be advisable to cover MSSA in an SDD-setting.
FISSA: A neuropil decontamination toolbox for calcium imaging signals.
Keemink, Sander W; Lowe, Scott C; Pakan, Janelle M P; Dylda, Evelyn; van Rossum, Mark C W; Rochefort, Nathalie L
2018-02-22
In vivo calcium imaging has become a method of choice to image neuronal population activity throughout the nervous system. These experiments generate large sequences of images. Their analysis is computationally intensive and typically involves motion correction, image segmentation into regions of interest (ROIs), and extraction of fluorescence traces from each ROI. Out of focus fluorescence from surrounding neuropil and other cells can strongly contaminate the signal assigned to a given ROI. In this study, we introduce the FISSA toolbox (Fast Image Signal Separation Analysis) for neuropil decontamination. Given pre-defined ROIs, the FISSA toolbox automatically extracts the surrounding local neuropil and performs blind-source separation with non-negative matrix factorization. Using both simulated and in vivo data, we show that this toolbox performs similarly or better than existing published methods. FISSA requires only little RAM, and allows for fast processing of large datasets even on a standard laptop. The FISSA toolbox is available in Python, with an option for MATLAB format outputs, and can easily be integrated into existing workflows. It is available from Github and the standard Python repositories.
Decontamination of drinking water by direct heating in solar panels.
Fjendbo Jørgensen, A J; Nøhr, K; Sørensen, H; Boisen, F
1998-09-01
A device was developed for direct heating of water by solar radiation in a flow-through system of copper pipes. An adjustable thermostat valve prevents water below the chosen temperature from being withdrawn. The results show that it is possible to eliminate coliform and thermotolerant coliform bacteria from naturally contaminated river water by heating to temperatures of 65 degrees C or above. Artificial additions of Salmonella typhimurium, Streptococcus faecalis and Escherichia coli to contaminated river water were also inactivated after heating to 65 degrees C and above. The total viable count could be reduced by a factor of 1000. The heat-resistant bacteria isolated from the Mlalakuva River (Tanzania) were spore-forming bacteria which exhibited greater heat resistance than commonly used test bacteria originating from countries with colder climates. To provide a good safety margin it is recommended that an outlet water temperature of 75 degrees C be used. At that temperature the daily production was about 501 of decontaminated water per m2 of solar panel, an amount that could be doubled by using a heat exchanger to recycle the heat.
Pinela, José; Ferreira, Isabel C F R
2017-07-03
Minimally processed fruits and vegetables are one of the major growing sectors in food industry. This growing demand for healthy and convenient foods with fresh-like properties is accompanied by concerns surrounding efficacy of the available sanitizing methods to appropriately deal with food-borne diseases. In fact, chemical sanitizers do not provide an efficient microbial reduction, besides being perceived negatively by the consumers, dangerous for human health, and harmful to the environment, and the conventional thermal treatments may negatively affect physical, nutritional, or bioactive properties of these perishable foods. For these reasons, the industry is investigating alternative nonthermal physical technologies, namely innovative packaging systems, ionizing and ultraviolet radiation, pulsed light, high-power ultrasound, cold plasma, high hydrostatic pressure, and dense phase carbon dioxide, as well as possible combinations between them or with other preservation factors (hurdles). This review discusses the potential of these novel or emerging technologies for decontamination and shelf-life extension of fresh and minimally processed fruits and vegetables. Advantages, limitations, and challenges related to its use in this sector are also highlighted.
HAZARDOUS WASTE DECONTAMINATION WITH PLASMA REACTORS
The use of electrical energy in the form of plasma has been considered as a potentially efficient means of decontaminating hazardous waste, although to date only a few attempts have been made to do so. There are a number of relative advantages and some potential disadvantages to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... decontamination levels set forth in this policy as constituting adequate cleanup of PCBs. (2) “Standards” refers to the numerical decontamination levels set forth in this policy. Residential/commercial areas means... designated agent (e.g., a facility manager or foreman). Soil means all vegetation, soils and other ground...
Evaluation of the Steris Sensitive Equipment Decontamination (SED) Apparatus on a 463L Pallet
2007-09-01
to decontaminate representative articles of sensitive equipment and operationally relevant materials for biological-warfare agent surrogate... Articles of Sensitive Equipment .................................................................. 25 2.9 Sensitive Equipment Inspection...45 3.6.2 Test Article Initial Inspection .............................................................. 47 3.6.3 Test
Muhammad, Nur; Heckman, Lee; Rice, Eugene W.; Hall, John
2012-01-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone. PMID:22267659
In-situ generation of chlorine dioxide for surface decontamination of produce
USDA-ARS?s Scientific Manuscript database
Fruits and vegetables, particularly fresh-cut products, are frequently contaminated with bacterial pathogens and implicated in foodborne illnesses. The objective of this study was to develop a unique in-situ sequential surface decontamination method for produce using sodium chlorite and acid. The ...
ProDeGe: A computational protocol for fully automated decontamination of genomes
Tennessen, Kristin; Andersen, Evan; Clingenpeel, Scott; ...
2015-06-09
Single amplified genomes and genomes assembled from metagenomes have enabled the exploration of uncultured microorganisms at an unprecedented scale. However, both these types of products are plagued by contamination. Since these genomes are now being generated in a high-throughput manner and sequences from them are propagating into public databases to drive novel scientific discoveries, rigorous quality controls and decontamination protocols are urgently needed. Here, we present ProDeGe (Protocol for fully automated Decontamination of Genomes), the first computational protocol for fully automated decontamination of draft genomes. ProDeGe classifies sequences into two classes—clean and contaminant—using a combination of homology and feature-based methodologies.more » On average, 84% of sequence from the non-target organism is removed from the data set (specificity) and 84% of the sequence from the target organism is retained (sensitivity). Lastly, the procedure operates successfully at a rate of ~0.30 CPU core hours per megabase of sequence and can be applied to any type of genome sequence.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stengl, Vaclav, E-mail: stengl@iic.cas.cz; Bludska, Jana; Oplustil, Frantisek
Highlights: {yields} New nano-dispersive materials for warfare agents decontamination. {yields} 95% decontamination activities for sulphur mustard. {yields} New materials base on titanium and manganese oxides. -- Abstract: Titanium(IV)-manganese(IV) nano-dispersed oxides were prepared by a homogeneous hydrolysis of potassium permanganate and titanium(IV) oxo-sulphate with 2-chloroacetamide. Synthesised samples were characterised using Brunauer-Emmett-Teller (BET) surface area and Barrett-Joiner-Halenda porosity (BJH), X-ray diffraction (XRD), infrared spectroscopy (IR), and scanning electron microscopy (SEM). These oxides were taken for an experimental evaluation of their reactivity with sulphur mustard (HD or bis(2-chloroethyl)sulphide) and soman (GD or (3,3'-dimethylbutan-2-yl)-methylphosphonofluoridate). Mn{sup 4+} content affects the decontamination activity; with increasing Mn{supmore » 4+} content the activity increases for sulphur mustard and decreases for soman. The best decontamination activities for sulphur mustard and soman were observed for samples TiMn{sub 3}7 with 18.6 wt.% Mn and TiMn{sub 5} with 2.1 wt.% Mn, respectively.« less
Assessment of microwave-based clinical waste decontamination unit.
Hoffman, P N; Hanley, M J
1994-12-01
A clinical waste decontamination unit that used microwave-generated heat was assessed for operator safety and efficacy. Tests with loads artificially contaminated with aerosol-forming particles showed that no particles were detected outside the machine provided the seals and covers were correctly seated. Thermometric measurement of a self-generated steam decontamination cycle was used to determine the parameters needed to ensure heat disinfection of the waste reception hopper, prior to entry for maintenance or repair. Bacterial and thermometric test pieces were passed through the machine within a full load of clinical waste. These test pieces, designed to represent a worst case situation, were enclosed in aluminium foil to shield them from direct microwave energy. None of the 100 bacterial test pieces yielded growth on culture and all 100 thermal test pieces achieved temperatures in excess of 99 degrees C during their passage through the decontamination unit. It was concluded that this method may be used to render safe the bulk of of ward-generated clinical waste.
Zirconium Hydroxide-coated Nanofiber Mats for Nerve Agent Decontamination.
Kim, Sohee; Ying, Wu Bin; Jung, Hyunsook; Ryu, Sam Gon; Lee, Bumjae; Lee, Kyung Jin
2017-03-16
Diverse innovative fabrics with specific functionalities have been developed for requirements such as self-decontamination of chemical/biological pollutants and toxic nerve agents. In this work, Zr(OH) 4 -coated nylon-6,6 nanofiber mats were fabricated for the decontamination of nerve agents. Nylon-6,6 fabric was prepared via the electrospinning process, followed by coating with Zr(OH) 4 , which was obtained by the hydrolysis of Zr(OBu) 4 by a sol-gel reaction on nanofiber surfaces. The reaction conditions were optimized by varying the amounts of Zr(OBu) 4 ,the reaction time, and the temperature of the sol-gel reaction. The composite nanofibers show high decontamination efficiency against diisopropylfluorophosphate, which is a nerve agent analogue, due to its high nucleophilicity that aids in the catalysis of the hydrolysis of the phosphonate ester bonds. Composite nanofiber mats have a large potential and can be applied in specific fields such as military and medical markets. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Decontamination of chemical warfare agents by photocatalysis].
Hirakawa, Tsutomu; Mera, Nobuaki; Sano, Taizo; Negishi, Nobuaki; Takeuchi, Koji
2009-01-01
Photocatalysis has been widely applied to solar-energy conversion and environmental purification. Photocatalyst, typically titanium dioxide (TiO(2)), produces active oxygen species under irradiation of ultraviolet light, and can decompose not only conventional pollutants but also different types of hazardous substances at mild conditions. We have recently started the study of photocatalytic decontamination of chemical warfare agents (CWAs) under collaboration with the National Research Institute of Police Science. This article reviews environmental applications of semiconductor photocatalysis, decontamination methods for CWAs, and previous photocatalytic studies applied to CWA degradation, together with some of our results obtained with CWAs and their simulant compounds. The data indicate that photocatalysis, which may not always give a striking power, certainly helps detoxification of such hazardous compounds. Unfortunately, there are not enough data obtained with real CWAs due to the difficulty in handling. We will add more scientific data using CWAs in the near future to develop useful decontamination systems that can reduce the damage caused by possible terrorism.
Athiban, Prakash P; Borthakur, Bikash Jyoti; Ganesan, S; Swathika, B
2012-01-01
Aim: The aim of this study was to evaluate the antimicrobial efficacy of Aloe vera and to determine its effectiveness in decontaminating gutta percha cones. Materials and Methods: A concentrated extract of Aloe vera was used to check for the antimicrobial efficacy using the agar well diffusion method. Presence of zones’ of diffusion was identified against three common GP contaminants namely, E.coli, E.faecalis and Staph. aureus. New GP Cones, freshly taken out of the packet were then decontaminated for 1minute using Aloe vera gel and then placed in thioglycolate broth to check for the presence of turbidity. Results: The zones of inhibition on the agar plate were measured as 24mm,21mm and 24mm respectively. The broth remained clear even after 48 hours of incubation. Conclusion: We conclude that Aloe vera is indeed effective as a GP decontaminant and it holds a promising future as a medium for storage of GP cones. PMID:22876011
Malek, Ammar; Hachemi, Messaoud; Didier, Villemin
2009-10-15
Herein, we describe an original novel method which allows the decontamination of the chromium-containing leather wastes to simplify the recovery of its considerable protein fractions. Organic salts and acids such as potassium oxalate, potassium tartrate, acetic and citric acids were tested for their efficiency to separate the chromium from the leather waste. Our investigation is based on the research of the total reversibility of the tanning process, in order to decontaminate the waste without its previous degradation or digestion. The effect of several influential parameters on the treatment process was also studied. Therefore, the action of chemical agents used in decontamination process seems very interesting. The optimal yield of chromium extraction about 95% is obtained. The aim of the present study is to define a preliminary processing of solid leather waste with two main impacts: Removing with reusing chromium in the tanning process with simple, ecological and economic treatment process and potential valorization of the organic matrix of waste decontaminated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-11-01
This US Nuclear Regulatory Commission report documents the circumstances surrounding the March 26, 1985, confiscation and subsequent decontamination activities related to the use of unauthorized quantities of americium-241 at the John C. Haynes Company (licensee) of Newark, Ohio. It focuses on the period from early February to July 26, 1985. The incident started when NRC Region III recieved information that John C. Haynes possessed unauthorized quantities of americium-241 and was conducting unauthorized activities (diamond irradiation). By July 26, 1985, the decontamination activities at the licensee's laboratory were concluded. The licensee's actions with diamond irradiation resulted in contamination in restricted andmore » unrestricted areas of the facility. The confiscation and decontamination activities required the combined efforts of NRC, Federal Bureau of Investigation, US Department of Energy, Oak Ridge Associated Universities, the State of Ohio, and the US Environmental Protection Agency. The report describes the factual information and significant findings associated with the confiscation and decontamination activities.« less
ProDeGe: A computational protocol for fully automated decontamination of genomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tennessen, Kristin; Andersen, Evan; Clingenpeel, Scott
Single amplified genomes and genomes assembled from metagenomes have enabled the exploration of uncultured microorganisms at an unprecedented scale. However, both these types of products are plagued by contamination. Since these genomes are now being generated in a high-throughput manner and sequences from them are propagating into public databases to drive novel scientific discoveries, rigorous quality controls and decontamination protocols are urgently needed. Here, we present ProDeGe (Protocol for fully automated Decontamination of Genomes), the first computational protocol for fully automated decontamination of draft genomes. ProDeGe classifies sequences into two classes—clean and contaminant—using a combination of homology and feature-based methodologies.more » On average, 84% of sequence from the non-target organism is removed from the data set (specificity) and 84% of the sequence from the target organism is retained (sensitivity). Lastly, the procedure operates successfully at a rate of ~0.30 CPU core hours per megabase of sequence and can be applied to any type of genome sequence.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ribas, Antonio G.S.; Abrao, Alcidio
1970-05-15
This paper describes the studies of decontamination of thorium present as impurity in uranyl nitrate solutions, which was carried out through strong cationic resin where the thorium was partially retained. Then, the final decontamination was performed percolating the uranyl solution on a second cationic resin, after complexation of thorium (and other impurities) with EDTA. The thorium decontamination and the uranium retention were studied as a function of EDTA/U ratio, uranium concentration and acidity of the influent uranyl nitrate. The elution conditions were also studied as a function of eluent flow rate, concentration and acidity. Several tables and graphs showing themore » final results are included. (tr-auth)« less
Radioactive scrap metal decontamination technology assessment report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buckentin, J.M.; Damkroger, B.K.; Schlienger, M.E.
1996-04-01
Within the DOE complex there exists a tremendous quantity of radioactive scrap metal. As an example, it is estimated that within the gaseous diffusion plants there exists in excess of 700,000 tons of contaminated stainless steel. At present, valuable material is being disposed of when it could be converted into a high quality product. Liquid metal processing represents a true recycling opportunity for this material. By applying the primary production processes towards the material`s decontamination and re-use, the value of the strategic resource is maintained while drastically reducing the volume of material in need of burial. Potential processes for themore » liquid metal decontamination of radioactively contaminated metal are discussed and contrasted. Opportunities and technology development issues are identified and discussed. The processes compared are: surface decontamination; size reduction, packaging and burial; melting technologies; electric arc melting; plasma arc centrifugal treatment; air induction melting; vacuum induction melting; and vacuum induction melting and electroslag remelting.« less
Decontamination of Drinking Water Infrastructure ...
Technical Brief This study examines the effectiveness of decontaminating corroded iron and cement-mortar coupons that have been contaminated with spores of Bacillus atrophaeus subsp. globigii (B. globigii), which is often used as a surrogate for pathogenic B. anthracis (anthrax) in disinfection studies. Bacillus spores are persistent on common drinking water material surfaces like corroded iron, requiring physical or chemical methods to decontaminate the infrastructure. In the United States, free chlorine and monochloramine are the primary chemical disinfectants used by the drinking water industry to inactivate microorganisms. Flushing is also a common, easily implemented practice in drinking water distribution systems, although large volumes of contaminated water needing treatment could be generated. Identifying readily available alternative disinfectant formulations for infrastructure decontamination could give water utilities options for responding to specific types of contamination events. In addition to presenting data on flushing alone, which demonstrated the persistence of spores on water infrastructure in the absence of high levels of disinfectants, data on acidified nitrite, chlorine dioxide, free chlorine, monochloramine, ozone, peracetic acid, and followed by flushing are provided.
Electrolytic decontamination of conductive materials
NASA Astrophysics Data System (ADS)
Campbell, George M.; Nelson, Timothy O.; Parker, John L.; Getty, Richard H.; Hergert, Tom R.; Lindahl, Kirk A.; Peppers, Larry G.
1994-10-01
Using the electrolytic method, we have demonstrated removal of Pu and Am from contaminated conductive material. At EG and G /Rocky Flats, we electrolytically decontaminated stainless steel. Results from this work show removal of fixed contamination, including the following geometries: planar, large radius, bolt holes, glove ports, and protruding studs. More specifically, fixed contamination was reduced from levels ranging from greater than 1 000 000 counts per minute (cpm) down to levels ranging from 1500 to 250 cpm using the electrolytic method. More recently, the electrolytic work has continued at Los Alamos National Laboratory as a joint project with EG and G/Rocky Flats. Impressively, electrolytic decontamination of Pu /Am from U surfaces (10 sq cm per side) shows decreases in swipable contamination from 500 000-1 500 000 disintegrations per minute (dpm) down to 0-2 dpm. Moreover, the solid waste product of the electrolytic method is reduced in volume by more than 50 times compared with the liquid waste produced by the previous U decontamination method -- a hot concentrated acid spray leach process.
Fighting Ebola with novel spore decontamination technologies for the military.
Doona, Christopher J; Feeherry, Florence E; Kustin, Kenneth; Olinger, Gene G; Setlow, Peter; Malkin, Alexander J; Leighton, Terrance
2015-01-01
Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC's novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus subtilis mutants to probe mechanisms of spore germination and inactivation. We employ techniques of high-resolution atomic force microscopy and phase contrast microscopy to examine the effects of γ-irradiation on bacterial spores of Bacillus anthracis, Bacillus thuringiensis, and Bacillus atrophaeus spp. and of ClO2 on B. subtilis spores, and present in detail assays using spore bio-indicators to ensure sterility when decontaminating with ClO2.
Tsubokura, Masaharu; Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro
2017-01-01
After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)-4.29 mSv), 0.37 mSv (range: ND-3.61 mSv), 0.22 mSv (range: ND-1.44 mSv), 0.20 mSv (range: ND-1.87 mSv), and 0.17 mSv (range: ND-0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04-0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses.
Lin, Tzu-Hsien; Chen, Chih-Chieh; Kuo, Chung-Wen
2017-01-01
This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority. PMID:29023492
de By, Theo M M H; McDonald, Carl; Süßner, Susanne; Davies, Jill; Heng, Wee Ling; Jashari, Ramadan; Bogers, Ad J J C; Petit, Pieter
2017-11-01
Surgeons needing human cardiovascular tissue for implantation in their patients are confronted with cardiovascular tissue banks that use different methods to identify and decontaminate micro-organisms. To elucidate these differences, we compared the quality of processing methods in 20 tissue banks and 1 reference laboratory. We did this to validate the results for accepting or rejecting tissue. We included the decontamination methods used and the influence of antibiotic cocktails and residues with results and controls. The minor details of the processes were not included. To compare the outcomes of microbiological testing and decontamination methods of heart valve allografts in cardiovascular tissue banks, an international quality round was organized. Twenty cardiovascular tissue banks participated in this quality round. The quality round method was validated first and consisted of sending purposely contaminated human heart valve tissue samples with known micro-organisms to the participants. The participants identified the micro-organisms using their local decontamination methods. Seventeen of the 20 participants correctly identified the micro-organisms; if these samples were heart valves to be released for implantation, 3 of the 20 participants would have decided to accept their result for release. Decontamination was shown not to be effective in 13 tissue banks because of growth of the organisms after decontamination. Articles in the literature revealed that antibiotics are effective at 36°C and not, or less so, at 2-8°C. The decontamination procedure, if it is validated, will ensure that the tissue contains no known micro-organisms. This study demonstrates that the quality round method of sending contaminated tissues and assessing the results of the microbiological cultures is an effective way of validating the processes of tissue banks. Only when harmonization, based on validated methods, has been achieved, will surgeons be able to fully rely on the methods used and have confidence in the consistent sterility of the tissue grafts. Tissue banks should validate their methods so that all stakeholders can trust the outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Berntssen, M H G; Olsvik, P A; Torstensen, B E; Julshamn, K; Midtun, T; Goksøyr, A; Johansen, J; Sigholt, T; Joerum, N; Jakobsen, J-V; Lundebye, A-K; Lock, E-J
2010-09-01
Oily fish are an important source of health promoting nutrients such as the very long chain marine omega-3 (VLC-n3) fatty acids and simultaneously a source of potentially hazardous contaminants. Fish oils that are used in fish feed are the main source for both contaminants and VLC-n3. Decontamination techniques have recently been developed to effectively remove persistent organic contaminants from fish oils. The aim of the present study was to assess the level of potentially hazardous contaminants and the health beneficial fatty acids in Atlantic salmon reared on novel decontaminated feeds. Atlantic salmon were fed for 18 months (an entire seawater production cycle) on diets based on decontaminated or non-treated (control) fish oils until market size (approximately 5 kg). The level of known notorious persistent organic pollutants (POPs, i.e. dioxins, dioxin-like polychlorinated biphenyls (DL-PCBs), non dioxin-like PCBs, poly brominated diphenyl ethers (PBDE), and organochlorine pesticides), as well as fatty acid composition were analysed in fish oils, the two diets, and Atlantic salmon fillet. The oil decontamination process was a two-step procedure using active carbon and short path distillation. The fillet levels of POPs in market size fish were reduced by 68-85% while the concentration of very long chain omega-3 fatty acids was reduced by 4-7%. No differences in biomarkers of dioxin-like component exposures, such as hepatic gene expression of CYP1A or AhR2B, CYP1A protein expression and 7-ethoxyresorufin O-deethylase (EROD) activity, were observed between salmon raised on normal or decontaminated feeds, thus indicating that the difference in POPs levels were of no biological significance to the fish. Atlantic salmon reared on decontaminated feeds had sum polychlorinated dibenzodioxins/furans (PCDD/Fs) and DL-PCB concentrations that were comparable with terrestrial food products such as beef, while the level of marine omega-3 fatty acids remained as high as for commercially farmed Atlantic salmon. (c) 2010 Elsevier Ltd. All rights reserved.
Salerno, Alicia; Devers, Thierry; Bolzinger, Marie-Alexandrine; Pelletier, Jocelyne; Josse, Denis; Briançon, Stéphanie
2017-04-01
Organophosphorus compounds (OP), which mainly penetrate via the percutaneous pathway, represent a threat for both military and civilians. Body surface decontamination is vital to prevent victims poisoning. The development of a cost-effective formulation, which could be efficient and easy to handle in case of mass contamination, is therefore crucial. Metal oxides nanoparticles, due their large surface areas and the large amount of highly reactive sites, present high reactivity towards OP. First, this study aimed at evaluating the reaction of CeO 2 nanoparticles, synthetized by microwave path and calcined at 500 or 600 °C, with Paraoxon (POX) in aqueous solution. Results showed that both nanoparticles degraded 60%-70% of POX. CeO 2 calcined at 500 °C, owing to its larger specific area, was the most effective. Moreover, the degradation was significantly increased under Ultra-Violet irradiation (initial degradation rate doubled). Then, skin decontamination was studied in vitro using the Franz cell method with pig-ear skin samples. CeO 2 powder and an aqueous suspension of CeO 2 (CeO 2 -W) were applied 1 h after POX exposure. The efficiency of decontamination, including removal and/or degradation of POX, was compared to Fuller's earth (FE) and RSDL lotion which are, currently, the most efficient systems for skin decontamination. CeO 2 -W and RSDL were the most efficient to remove POX from the skin surface and decrease skin absorption by 6.4 compared to the control not decontaminated. FE reduced significantly (twice) the absorbed fraction of POX, contrarily to CeO 2 powder. Considering only the degradation rate of POX, the products ranged in the order CeO 2 > RSDL > CeO 2 -W > FE (no degradation). This study showed that CeO 2 nanoparticles are a promising material for skin decontamination of OP if formulated as a dispersion able to remove POX like CeO 2 -W and to degrade it as CeO 2 powder. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Zhengkai; Wang, Haihong; Luo, Zhicai
2017-04-01
Due to the complex coastal topography and energetic ocean dynamics effect, the return echoes are contaminated while the satellite footprint approaches or leaves the coastline. Specular peaks are often induced in the trailing edges of contaminated waveforms, thus leading the error in the determination of the leading edge and associated track offset in the waveform retracking process. We propose an improved algorithm base on Tseng's modification method to decontaminated coastal (0-7 km from coastline) waveforms, thus improving both the utilization and precision of coastal sea surface height (SSH). Using the Envisat/Jason-2 SGDR data, the shortcoming of Tseng's method is pointed out and the novel algorithm is proposed by revising the strategy of selecting reference waveform and determining weight for removing outlier. The reference waveform of the decontaminated technology is closer to the real waveform of the offshore area, which avoids the over-modification problem of Tseng method. The sea-level measurements from tide gauge station and geoid height from EGM2008 model were used to validate the retracking strategy. Experimental results show that decontaminated waveform was more suitable than original and Tseng modified waveform and has uniform performance in both compare to the tide gauge and geoid. The retrieved altimetry data in the 0-1km and 1-7km coastal zone indicate that threshold retracker with decontaminated waveform have STD of 73.8cm and 33cm as compared with in situ gauge data,which correspond to 62.1% and 58% in precession compared to the unretracked altimetry measurements. The retracked SSHs are better in two coastal (0-1 km and 1-7km) zones, which have STD of 11.9cm and 22.7cm as compared with geoid height. Furthermore, the comparisons shows that the precision of decontaminated technology improve 0.3cm and 3.3cm than the best result of PISTACH product in coastal sea. This work is supported by the National Natural Science Foundation of China (Grant Nos. 41174020, 41174021, 41131067) and the open fund of Guangxi Key Laboratory of Spatial Information and Geometrics (Grant No. 15-140-07-26). Index Terms: retracking, Envisat, Jason-2, Coastal sea, decontamination.
Fighting Ebola with novel spore decontamination technologies for the military
Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth; Olinger, Gene G.; Setlow, Peter; Malkin, Alexander J.; Leighton, Terrance
2015-01-01
Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC’s novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus subtilis mutants to probe mechanisms of spore germination and inactivation. We employ techniques of high-resolution atomic force microscopy and phase contrast microscopy to examine the effects of γ-irradiation on bacterial spores of Bacillus anthracis, Bacillus thuringiensis, and Bacillus atrophaeus spp. and of ClO2 on B. subtilis spores, and present in detail assays using spore bio-indicators to ensure sterility when decontaminating with ClO2. PMID:26322021
DOE Office of Scientific and Technical Information (OSTI.GOV)
Millar, J.S.; Pottmeyer, J.A.; Stratton, T.J.
1995-01-01
Purpose of the study was to estimate the amounts of equipment and other materials that are candidates for removal and subsequent processing in a solid waste facility when the Hanford Plutonium Finishing Plant is decontaminated and decommissioned. (Building structure and soil are not covered.) Results indicate that {approximately}5,500 m{sup 3} of solid waste is expected to result from the decontamination and decommissioning of the Pu Finishing Plant. The breakdown of the volumes and percentages of waste by category is 1% dangerous solid waste, 71% low-level waste, 21% transuranic waste, 7% transuranic mixed waste.
NASA Astrophysics Data System (ADS)
Migdal, W.; Owczarczyk, B.; Kedzia, B.; Holderna-Kedzia, E.; Segiet-Kujawa, E.
1998-06-01
Several thousand tons of medical herbs are produced annually by pharmaceutical industry in Poland. This product should be of highest quality and microbial purity. Recently, chemical methods of decontamination are recognized as less safe, thus irradiation technique was chosen to replace them in use. In the Institute of Nuclear Chemistry and Technology the national program on the application of irradiation to the decontamination of medical herbs is in progress now. The purpose of the program is to elaborate, on the basis of research work, the facility standards and technological instructions indispensable for the practice of radiation technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Won-Seok; Nam, Seongsik; Chang, Seeun
Decontamination techniques proposed and used to remove Chalk River unidentified deposit (CRUD) in radioactive waste management. In cases of huge volumes of metal or radionuclides contaminated by CRUD, removal of CRUD by mechanical or chemical decontamination is difficult. An advanced electrokinetic process combined with chemical decontamination was applied to remove CRUD and experimentally evaluated. We used oxalic acid for CRUD removal, and cobalt (Co) released from the CRUD was transferred to the cathode in an electrokinetic reactor. Our results indicate that the combined system is efficient for CRUD removal with enhanced, efficiency by use of the cation exchange membrane andmore » zeolite.« less
Kim, Won-Seok; Nam, Seongsik; Chang, Seeun; ...
2017-08-13
Decontamination techniques proposed and used to remove Chalk River unidentified deposit (CRUD) in radioactive waste management. In cases of huge volumes of metal or radionuclides contaminated by CRUD, removal of CRUD by mechanical or chemical decontamination is difficult. An advanced electrokinetic process combined with chemical decontamination was applied to remove CRUD and experimentally evaluated. We used oxalic acid for CRUD removal, and cobalt (Co) released from the CRUD was transferred to the cathode in an electrokinetic reactor. Our results indicate that the combined system is efficient for CRUD removal with enhanced, efficiency by use of the cation exchange membrane andmore » zeolite.« less
Removal of uranyl ions by p-hexasulfonated calyx[6]arene acid
NASA Astrophysics Data System (ADS)
Popescu (Hoştuc), Ioana-Carmen; Petru, Filip; Humelnicu, Ionel; Mateescu, Marina; Militaru, Ecaterina; Humelnicu, Doina
2014-10-01
Radioactive pollution is a significant threat for the people's health. Therefore highly effective radioactive decontamination methods are required. Ion exchange, biotechnologies and phytoremediation in constructed wetlands have been used as radioactive decontamination technologies for uranium contaminated soil and water remediation. Recently, beside those classical methods the calix[n]arenic derivatives' utilization as radioactive decontaminators has jogged attention. The present work aims to present the preliminary research results of uranyl ion sorption studies on the p-hexasulfonated calyx[6]arenic acid. The effect of temperature, contact time, sorbent amount and uranyl concentration variation on sorption efficiency was investigated. Isotherm models revealed that the sorption process fit better Langmuir isotherm.
40 CFR 264.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment, structures and soils. 264.114 Section 264.114 Protection of Environment ENVIRONMENTAL PROTECTION... of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soils must be properly disposed of or decontaminated unless otherwise specified in...
40 CFR 264.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equipment, structures and soils. 264.114 Section 264.114 Protection of Environment ENVIRONMENTAL PROTECTION... of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soils must be properly disposed of or decontaminated unless otherwise specified in...
40 CFR 264.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipment, structures and soils. 264.114 Section 264.114 Protection of Environment ENVIRONMENTAL PROTECTION... of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soils must be properly disposed of or decontaminated unless otherwise specified in...
40 CFR 264.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2010 CFR
2010-07-01
... equipment, structures and soils. 264.114 Section 264.114 Protection of Environment ENVIRONMENTAL PROTECTION... of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soils must be properly disposed of or decontaminated unless otherwise specified in...
40 CFR 264.114 - Disposal or decontamination of equipment, structures and soils.
Code of Federal Regulations, 2013 CFR
2013-07-01
... equipment, structures and soils. 264.114 Section 264.114 Protection of Environment ENVIRONMENTAL PROTECTION... of equipment, structures and soils. During the partial and final closure periods, all contaminated equipment, structures and soils must be properly disposed of or decontaminated unless otherwise specified in...
WIRELESS ELECTROCHEMICAL CLO2 MONITOR FOR DECONTAMINATION OPERATIONS - PHASE I
The U.S. Environmental Protection Agency has identified the need for an accurate and field-rugged instrument to monitor chlorine dioxide (ClO2) for use in monitoring building decontamination operations.
The proposed Phase I study will evaluate the feasibil...
WIRELESS ELECTROCHEMICAL CLO2 MONITOR FOR DECONTAMINATION OPERATIONS - PHASE II
Recognizing the importance of ClO2 in disinfection and decontamination operations, the U.S. Environmental Protection Agency (EPA) had identified the need for portable, accurate and field-rugged chlorine dioxide (ClO2) monitors for use in monitoring buildi...
To support the Nation's Homeland Security Program, this U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) project is conducted to verify the performance of commercially available products, methods, and equipment for decontamination of hard and...
This page contains information about approvals and notifications for Enviro Jet to Decontaminate PCB-contaminated natural gas pipelines under Title 40 of the Code of Federal Regulations (CFR) Section 761.79(h)
Bebko, Serge P; Green, David M; Awad, Samir S
2015-05-01
Surgical site infections (SSIs), commonly caused by methicillin-resistant Staphylococcus aureus (MRSA), are associated with significant morbidity and mortality, specifically when hardware is implanted in the patient. Previously, we have demonstrated that a preoperative decontamination protocol using chlorhexidine gluconate washcloths and intranasal antiseptic ointment is effective in eradicating MRSA in the nose and on the skin of patients. To examine the effect of a decontamination protocol on SSIs in patients undergoing elective orthopedic surgery with hardware implantation. A prospective database of patients undergoing elective orthopedic surgery with hardware implantation at the Michael E. DeBakey Veterans Affairs Medical Center in Houston, Texas, was analyzed from October 1, 2012, to December 31, 2013. Cohort groups before and after the intervention were compared. Starting in May 2013, during their preoperative visit, all of the patients watched an educational video about MRSA decontamination and were given chlorhexidine washcloths and oral rinse and nasal povidone-iodine solution to be used the night before and the morning of scheduled surgery. Thirty-day SSI rates were collected according to the definitions of the Centers for Disease Control and Prevention National Nosocomial Infections Surveillance. Data on demographics, comorbidities such as chronic obstructive pulmonary disease and coronary artery disease, tobacco use, alcohol use, and body mass index were also collected. Univariate analysis was performed between the 2 groups of patients. Multivariate analysis was used to identify independent predictors of SSI. A total of 709 patients were analyzed (344 controls and 365 patients who were decolonized). Both groups were well matched with no significant differences in age, body mass index, sex, or comorbidities. All of the patients (100%) completed the MRSA decontamination protocol. The SSI rate in the intervention group was significantly lower (1.1%; 4 of 365 patients developed an SSI) than the SSI rate in the control group (3.8%; 13 of 344 patients developed an SSI) (P = .02). Multivariate logistic regression identified MRSA decontamination as an independent predictor of not developing an SSI (adjusted odds ratio, 0.24 [95% CI, 0.08-0.77]; P = .02). Our study demonstrates that preoperative MRSA decontamination with chlorhexidine washcloths and oral rinse and intranasal povidone-iodine decreased the SSI rate by more than 50% among patients undergoing elective orthopedic surgery with hardware implantation. Universal decontamination using this low-cost protocol may be considered as an additional prevention strategy for SSIs in patients undergoing orthopedic surgery with hardware implantation and warrants further study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rick Demmer; John Drake; Ryan James, PhD
Over the last 50 years, the study of radiological contamination and decontamination has expanded significantly. This paper addresses the mechanisms of radiological contamination that have been reported and then discusses which methods have recently been used during performance testing of several different decontamination technologies. About twenty years ago the Idaho Nuclear Technology Engineering Center (INTEC) at the INL began a search for decontamination processes which could minimize secondary waste. In order to test the effectiveness of these decontamination technologies, a new simulated contamination, termed SIMCON, was developed. SIMCON was designed to replicate the types of contamination found on stainless steel,more » spent fuel processing equipment. Ten years later, the INL began research into methods for simulating urban contamination resulting from a radiological dispersal device (RDD). This work was sponsored by the Defense Advanced Research Projects Agency (DARPA) and included the initial development an aqueous application of contaminant to substrate. Since 2007, research sponsored by the US Environmental Protection Agency (EPA) has advanced that effort and led to the development of a contamination method that simulates particulate fallout from an Improvised Nuclear Device (IND). The IND method diverges from previous efforts to create tenacious contamination by simulating a reproducible “loose” contamination. Examining these different types of contamination (and subsequent decontamination processes), which have included several different radionuclides and substrates, sheds light on contamination processes that occur throughout the nuclear industry and in the urban environment.« less
Vandermoere, Frédéric
2008-04-01
This case study examines the hazard and risk perception and the need for decontamination according to people exposed to soil pollution. Using an ecological-symbolic approach (ESA), a multidisciplinary model is developed that draws upon psychological and sociological perspectives on risk perception and includes ecological variables by using data from experts' risk assessments. The results show that hazard perception is best predicted by objective knowledge, subjective knowledge, estimated knowledge of experts, and the assessed risks. However, experts' risk assessments induce an increase in hazard perception only when residents know the urgency of decontamination. Risk perception is best predicted by trust in the risk management. Additionally, need for decontamination relates to hazard perception, risk perception, estimated knowledge of experts, and thoughts about sustainability. In contrast to the knowledge deficit model, objective and subjective knowledge did not significantly relate to risk perception and need for decontamination. The results suggest that residents can make a distinction between hazards in terms of the seriousness of contamination on the one hand, and human health risks on the other hand. Moreover, next to the importance of social determinants of environmental risk perception, this study shows that the output of experts' risk assessments-or the objective risks-can create a hazard awareness rather than an alarming risk consciousness, despite residents' distrust of scientific knowledge.
Dorandeu, F; Taysse, L; Boudry, I; Foquin, A; Hérodin, F; Mathieu, J; Daulon, S; Cruz, C; Lallement, G
2011-06-01
Exposure to lethal chemical warfare agents (CWAs) is no longer only a military issue due to the terrorist threat. Among the CWAs of concern are the organophosphorus nerve agent O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX) and the vesicant sulfur mustard (SM). Although efficient means of decontamination are available, most of them lose their efficacy when decontamination is delayed after exposure of the bare skin. Alternatively, CWA skin penetration can be prevented by topical skin protectants. Active research in skin protection and decontamination is thus paramount. In vivo screening of decontaminants or skin protectants is usually time consuming and may be expensive depending on the animal species used. We were thus looking for a suitable, scientifically sound and cost-effective model, which is easy to handle. The euthymic hairless mouse Crl: SKH-1 (hr/hr) BR is widely used in some skin studies and has previously been described to be suitable for some experiments involving SM or SM analogs. To evaluate the response of this species, we studied the consequences of exposing male anaesthetized SKH-1 mice to either liquid VX or to SM, the latter being used in liquid form or as saturated vapours. Long-term effects of SM burn were also evaluated. The model was then used in the companion paper (Taysse et al.(1)).
Decontamination issues for chemical and biological warfare agents: how clean is clean enough?
Raber, E; Jin, A; Noonan, K; McGuire, R; Kirvel, R D
2001-06-01
The objective of this assessment is to determine what level of cleanup will be required to meet regulatory and stakeholder needs in the case of a chemical and/or biological incident at a civilian facility. A literature review for selected, potential chemical and biological warfare agents shows that dose information is often lacking or controversial. Environmental regulatory limits or other industrial health guidelines that could be used to help establish cleanup concentration levels for such agents are generally unavailable or not applicable for a public setting. Although dose information, cleanup criteria, and decontamination protocols all present challenges to effective planning, several decontamination approaches are available. Such approaches should be combined with risk-informed decision making to establish reasonable cleanup goals for protecting health, property, and resources. Key issues during a risk assessment are to determine exactly what constitutes a safety hazard and whether decontamination is necessary or not for a particular scenario. An important conclusion is that cleanup criteria are site dependent and stakeholder specific. The results of a modeling exercise for two outdoor scenarios are presented to reinforce this conclusion. Public perception of risk to health, public acceptance of recommendations based on scientific criteria, political support, time constraints, and economic concerns must all be addressed in the context of a specific scenario to yield effective and acceptable decontamination.
NASA Astrophysics Data System (ADS)
Herrmann, Hans W.
1998-11-01
The atmospheric pressure plasma jet (APPJ) is a non-thermal, high pressure, uniform glow discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g. He/O_2/H_2O) which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz RF. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains metastables (e.g. O2*, He*) and radicals (e.g. O, OH). These reactive species have been shown to be effective neutralizers of surrogates for anthrax spores, mustard blister agent and VX nerve gas. Unlike conventional, wet decontamination methods, the plasma effluent does not cause corrosion of most surfaces and does not damage wiring, electronics, nor most plastics. This makes it highly suitable for decontamination of high value sensitive equipment such as is found in vehicle interiors (i.e. tanks, planes...) for which there is currently no good decontamination technique. Furthermore, the reactive species rapidly degrade into harmless products leaving no lingering residue or harmful byproducts. Physics of the APPJ will be discussed and results of surface decontamination experiments using simulant and actual CBW agents will be presented.