Thermal expansion method for lining tantalum alloy tubing with tungsten
NASA Technical Reports Server (NTRS)
Watson, G. K.; Whittenberger, J. D.; Mattson, W. F.
1973-01-01
A differential-thermal expansion method was developed to line T-111 (tantalum - 8 percent tungsten - 2 percent hafnium) tubing with a tungsten diffusion barrier as part of a fuel element fabrication study for a space power nuclear reactor concept. This method uses a steel mandrel, which has a larger thermal expansion than T-111, to force the tungsten against the inside of the T-111 tube. Variables investigated include lining temperature, initial assembly gas size, and tube length. Linear integrity increased with increasing lining temperature and decreasing gap size. The method should have more general applicability where cylinders must be lined with a thin layer of a second material.
Dumpa, Vikramaditya; Adler, Bonny; Allen, Delena; Bowman, Deborah; Gram, Amy; Ford, Pat; Sannoh, Sulaiman
2016-01-01
Advances in neonatology led to survival of micro-preemies, who need central lines. Central line-associated bloodstream infection (CLABSI) causes prolonged hospitalization, morbidities, and mortality. Health care team education decreases CLABSIs. The objective was to decrease CLABSIs using evidence-based measures. The retrospective review compared CLABSI incidence during and after changes in catheter care. In April 2011, intravenous (IV) tubing changed from Interlink to Clearlink; IV tubing changing interval increased from 24 to 72 hours. CLABSIs increased. The following measures were implemented: July 2011, reeducation of neonatal intensive care staff on Clearlink; August 2011, IV tubing changing interval returned to 24 hours; September 2011, changed from Clearlink back to Interlink; November 2011, review of entire IV process and in-service on hand hygiene; December 2011, competencies on IV access for all nurses. CLABSIs were compared during and after interventions. Means were compared using the t test and ratios using the χ(2) test; P <.05. CLABSIs decreased from 4.4/1000 to 0/1000 catheter-days; P < .05. Evidence-based interventions reduced CLABSIs. © The Author(s) 2014.
NASA Astrophysics Data System (ADS)
Dev, A. A.; Atrey, M. D.; Vanapalli, S.
2017-02-01
A transfer line between a pulse tube cold head and a pressure wave generator is usually required to isolate the cold head from the vibrations of the compressor. Although it is a common practice to use a thin and narrow straight tube, a bent tube would allow design flexibility and easy mounting of the cold head, such as in a split Stirling type pulse tube cryocooler. In this paper, we report a preliminary investigation on the effect of the bending of the tube on the flow transfer characteristics. A numerical study using commercial computational fluid dynamics model is performed to gain insight into the flow characteristics in the bent tube. Oscillating flow experiments are performed with a straight and a bent tube at a filling pressure of 15 bar and an operating frequency of 40, 50 and 60 Hz. The data and the corresponding numerical simulations point to the hypothesis that the secondary flow in the bent tube causes a decrease in flow at a fixed pressure amplitude.
Proximal suction tracheotomy tube reduces aspiration volume.
Coffman, Heather M S; Rees, Catherine J; Sievers, Ann E F; Belafsky, Peter C
2008-04-01
Conventional cuffed tracheotomy tubes do not prevent aspiration of secretions. Aspiration of saliva may be decreased with the use of a subglottic suction port. Prospective. Shiley Disposable Cuffed Tracheotomy (DCT) tubes sizes 4, 6, and 8 (Tyco Healthcare, Pleasanton, CA) were compared to Portex Blue Line Ultra Suctionaid (BLUS) tracheotomy tubes sizes 6, 7, and 8 (Fig 1; Smiths Medical, Watford, UK). All tubes were tested in a simulated tracheal model using 10 cc of human saliva with no suction, intermittent suction, and constant suction (15 minutes). There was a significant decrease in aspirate between the larger Shiley and BLUS tubes with intermittent suction (mean 8.38 mL Shiley 6 vs 1.60 mL BLUS 7; 8.50 mL Shiley 8 vs 2.80 mL BLUS 8). There was a significant decrease in aspirate between all sizes of Shiley and BLUS tubes with continuous suction. For BLUS 7 and 8, there was a significant difference between intermittent suction (mean, 1.60 mL, 2.80 mL, respectively) and continuous suction (mean, 0.20 mL, 0.60 mL respectively). Shiley and BLUS without suction were equivalent. Subglottic suction tracheotomy tubes reduce the risk of aspiration beyond the cuff in a bench-top model.
Crushing characteristics of composite tubes with 'near-elliptical' cross sections
NASA Astrophysics Data System (ADS)
Farley, Gary L.; Jones, Robert M.
1992-01-01
An experimental investigation was conducted to determine whether the energy-absorption capability of near-elliptical cross-section composite tubular specimens is a function of included angle. Each half of the near-elliptical cross-section tube is a segment of a circle. The included angle is the angle created by radial lines extending from the center of the circular segment to the ends of the circular segment. Graphite- and Kevlar-reinforced epoxy material was used to fabricate specimens. Tube internal diameters were 2.54, 3.81, and 7.62 cm, and included angles were 180, 160, 135, and 90 degrees. Based upon the test results from these tubes, energy-absorption capability increased between 10 and 30 percent as included angle decreased between 180 and 90 degrees for the materials evaluated. Energy-absorption capability was a decreasing nonlinear function of the ratio of tube internal diameter to wall thickness.
Nitrogen gas propagation in a liquid helium cooled vacuum tube following a sudden vacuum loss
NASA Astrophysics Data System (ADS)
Dhuley, R. C.; Van Sciver, S. W.
2017-02-01
We present experimental measurements and analysis of propagation of the nitrogen gas that was vented to a high vacuum tube immersed in liquid helium (LHe). The scenario resembles accidental venting of atmospheric air to a SRF beam-line and was investigated to understand how the in-flowing air would propagate in such geometry. The gas front propagation speed in the tube was measured using pressure probes and thermometers installed at regular intervals over the tube length. The experimental data show the front speed to decrease along the vacuum tube. The empirical and analytical models developed to characterize the front deceleration are summarized.
Using higher doses to compensate for tubing residuals in extended-infusion piperacillin-tazobactam.
Lam, Wendy J; Bhowmick, Tanaya; Gross, Alan; Vanschooneveld, Trevor C; Weinstein, Melvin P
2013-06-01
To mathematically assess drug losses due to infusion line residuals and evaluate methods to compensate for drug loss due to residual volumes in intravenous pump tubing. Literature was accessed through Ovid MEDLINE (1996-February 2013), using combinations of the search terms tubing residuals, residual volume, residual medication, intravenous infusions, intravenous injections, piperacillin, piperacillin-tazobactam, β-lactams, equipment design, infusion pumps, extended infusion, extended administration, and prolonged infusion. In addition, select reference citations from publications identified were reviewed. All articles that involved extended-infusion piperacillin-tazobactam implementation strategies were included in the review. Infusion pump characteristics and tubing residuals can affect extended-infusion piperacillin-tazobactam dosing strategies. Two studies addressing tubing residuals were identified. Both studies recommended increasing infusion volumes to compensate for tubing residuals. One study also recommended decreasing infusion-line dead space by using alternative infusion pump systems. Study calculations suggest that higher doses of piperacillin-tazobactam may be used to account for medication left in tubing residuals if alternative infusion pump systems cannot be obtained, and increased infusion volumes are not an option. Extended-infusion piperacillin-tazobactam has been used as a method of maximizing pharmacodynamic target attainment. Use of higher doses of piperacillin-tazobactam may be a reasonable method to compensate for drug loss due to residual volumes in large-bore intravenous pump tubing.
Surfactant effects on contact line alteration of a liquid drop in a capillary tube
NASA Astrophysics Data System (ADS)
Yulianti, K.; Marwati, R.
2018-05-01
In this paper, the effect of an insoluble surfactant on the moving contact line of an interface between two fluids filling a capillary tube is studied. The governing equations are the incompressible Navier-Stokes equations with the couple of Eulerian fluid variables and Lagrangian interfacial markers. In our model, capillary force plays a role in the fluids motion. Here, we propose that besides lowering the interfacial tension which affects the capillary force, the surfactant also decreases the surface tension between fluids and a solid surface. That condition is applied to the unbalanced Young condition at the contact line. The front-tracking method is used to solve numerically the free boundary motion of the interface. Results show that the surfactant has a significant effect on the motion of the contact line.
Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year.
Porteous, N; Dang, S; Schoolfield, J; Sun, Y
2016-03-01
The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student's t-tests. An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used.
Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year
Porteous, N.; Dang, S.; Schoolfield, J.; Sun, Y.
2017-01-01
Objective The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). Methods A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student’s t-tests. Results An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. Conclusions No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used. PMID:28390212
Erosion by flowing lava: Geochemical evidence in the Cave Basalt, Mount St. Helens, Washington
Williams, D.A.; Kadel, S.D.; Greeley, R.; Lesher, C.M.; Clynne, M.A.
2004-01-01
We sampled basaltic lava flows and underlying dacitic tuff deposits in or near lava tubes of the Cave Basalt, Mount St. Helens, Washington to determine whether the Cave Basalt lavas contain geochemical evidence of substrate contamination by lava erosion. The samples were analyzed using a combination of wavelength-dispersive X-ray fluorescence spectrometry and inductively-coupled plasma mass spectrometry. The results indicate that the oldest, outer lava tube linings in direct contact with the dacitic substrate are contaminated, whereas the younger, inner lava tube linings are uncontaminated and apparently either more evolved or enriched in residual liquid. The most heavily contaminated lavas occur closer to the vent and in steeper parts of the tube system, and the amount of contamination decreases with increasing distance downstream. These results suggest that erosion by lava and contamination were limited to only the initially emplaced flows and that erosion was localized and enhanced by vigorous laminar flow over steeper slopes. After cooling, the initial Cave Basalt lava flows formed an insulating lining within the tubes that prevented further erosion by later flows. This interpretation is consistent with models of lava erosion that predict higher erosion rates closer to sources and over steeper slopes. A greater abundance of xenoliths and xenocrysts relative to xenomelts in hand samples indicates that mechanical erosion rather than thermal erosion was the dominant erosional process in the Cave Basalt, but further sampling and petrographic analyses must be performed to verify this hypothesis. ?? Springer-Verlag 2003.
Gas propagation in a liquid helium cooled vacuum tube following a sudden vacuum loss
NASA Astrophysics Data System (ADS)
Dhuley, Ram C.
This dissertation describes the propagation of near atmospheric nitrogen gas that rushes into a liquid helium cooled vacuum tube after the tube suddenly loses vacuum. The loss-of-vacuum scenario resembles accidental venting of atmospheric air to the beam-line of a superconducting radio frequency particle accelerator and is investigated to understand how in the presence of condensation, the in-flowing air will propagate in such geometry. In a series of controlled experiments, room temperature nitrogen gas (a substitute for air) at a variety of mass flow rates was vented to a high vacuum tube immersed in a bath of liquid helium. Pressure probes and thermometers installed on the tube along its length measured respectively the tube pressure and tube wall temperature rise due to gas flooding and condensation. At high mass in-flow rates a gas front propagated down the vacuum tube but with a continuously decreasing speed. Regression analysis of the measured front arrival times indicates that the speed decreases nearly exponentially with the travel length. At low enough mass in-flow rates, no front propagated in the vacuum tube. Instead, the in-flowing gas steadily condensed over a short section of the tube near its entrance and the front appeared to `freeze-out'. An analytical expression is derived for gas front propagation speed in a vacuum tube in the presence of condensation. The analytical model qualitatively explains the front deceleration and flow freeze-out. The model is then simplified and supplemented with condensation heat/mass transfer data to again find the front to decelerate exponentially while going away from the tube entrance. Within the experimental and procedural uncertainty, the exponential decay length-scales obtained from the front arrival time regression and from the simplified model agree.
Gray, G.W.; Jensen, A.S.
1957-10-22
A pulse-height analyzer system of improved design for sorting and counting a series of pulses, such as provided by a scintillation detector in nuclear radiation measurements, is described. The analyzer comprises a main transmission line, a cathode-ray tube for each section of the line with its deflection plates acting as the line capacitance; means to bias the respective cathode ray tubes so that the beam strikes a target only when a prearranged pulse amplitude is applied, with each tube progressively biased to respond to smaller amplitudes; pulse generating and counting means associated with each tube to respond when the beam is deflected; a control transmission line having the same time constant as the first line per section with pulse generating means for each tube for initiating a pulse on the second transmission line when a pulse triggers the tube of corresponding amplitude response, the former pulse acting to prevent successive tubes from responding to the pulse under test. This arrangement permits greater deflection sensitivity in the cathode ray tube and overcomes many of the disadvantages of prior art pulse-height analyzer circuits.
Experimental investigation of two-phase flow patterns in minichannels at horizontal orientation
NASA Astrophysics Data System (ADS)
Saljoshi, P. S.; Autee, A. T.
2017-09-01
Two-phase flow is the simplest case of multiphase flow in which two phases are present for a pure component. The mini channel is considered as diameter below 3.0-0.2 mm and conventional channel is considered diameter above 3.0 mm. An experiment was conducted to study the adiabatic two-phase flow patterns in the circular test section with inner diameter of 1.1, 1.63, 2.0, 2.43 and 3.0 mm for horizontal orientation using air and water as a fluid. Different types of flow patterns found in the experiment. The parameters that affect most of these patterns and their transitions are channel size, phase superficial velocities (air and liquid) and surface tension. The superficial velocity of liquid and gas ranges from 0.01 to 66.70 and 0.01 to 3 m/s respectively. Two-phase flow pattern photos were recorded using a high speed CMOS camera. In this experiment different flow patterns were identified for different tube diameters that confirm the diameter effect on flow patterns in two-phase flows. Stratified flow was not observed for tube diameters less than 3.0 mm. Similarly, wavy-annular flow pattern was not observed in 1.6 and 1.0 mm diameter tubes due to the surface-tension effect and decrease in tube diameter. Buoyancy effects were clearly visible in 2.43 and 3.0 mm diameter tubes flow pattern. It has also observed that as the test-section diameter decreases the transition lines shift towards the higher gas and liquid velocity. However, the result of flow pattern lines in the present study has good agreement with the some of the existing flow patterns maps.
Neural Tube Defects, Folic Acid and Methylation
Imbard, Apolline; Benoist, Jean-François; Blom, Henk J.
2013-01-01
Neural tube defects (NTDs) are common complex congenital malformations resulting from failure of the neural tube closure during embryogenesis. It is established that folic acid supplementation decreases the prevalence of NTDs, which has led to national public health policies regarding folic acid. To date, animal studies have not provided sufficient information to establish the metabolic and/or genomic mechanism(s) underlying human folic acid responsiveness in NTDs. However, several lines of evidence suggest that not only folates but also choline, B12 and methylation metabolisms are involved in NTDs. Decreased B12 vitamin and increased total choline or homocysteine in maternal blood have been shown to be associated with increased NTDs risk. Several polymorphisms of genes involved in these pathways have also been implicated in risk of development of NTDs. This raises the question whether supplementation with B12 vitamin, betaine or other methylation donors in addition to folic acid periconceptional supplementation will further reduce NTD risk. The objective of this article is to review the role of methylation metabolism in the onset of neural tube defects. PMID:24048206
Impact of tubing length on hemodynamics in a simulated neonatal extracorporeal life support circuit.
Qiu, Feng; Uluer, Mehmet C; Kunselman, Allen; Clark, J Brian; Myers, John L; Undar, Akif
2010-11-01
During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8Fr Biomedicus arterial and a 10Fr Biomedicus venous cannula were connected to the pseudopatient. One-fourth inch tubing was used for both the arterial and the venous line. A Hoffman clamp was located upstream from the pseudopatient to maintain a certain patient pressure. Three pressure transducers were placed at different sites: postoxygenator, prearterial cannula, and postarterial cannula. The system was primed with Lactated Ringer's solution; human blood was then added to maintain a hematocrit of 40%. The volume of the pseudopatient was 500mL. We hemodynamically evaluated three circuits with different lengths of tubing: 6, 4, and 2 feet (182.88, 121.92, and 60.96 cm, respectively) for both arterial and venous lines; the priming volumes including all of the components of the circuits were 195, 155, and 115mL, respectively. In each circuit, we measured the pressure drops of the arterial tubing and the arterial cannula, as well as the flow rates at different rpm (1750-3000, 250 intervals) under three patient pressures (40, 60, and 80mm Hg). All the experiments were conducted at 37°C. The pressure drop across the arterial cannula is much larger than that of arterial tubing in all set-ups, especially under high flow rates. Upon cutting the tubing from 6 to 2 feet, the pressure drop of the arterial tubing decreased by half, while the pressure drop of the arterial cannula increased due to the slightly higher flow rates. These results suggest that compared to the arterial tubing, the arterial cannula has a larger impact on the hemodynamics of the circuit. There is a little influence of tubing length on the circuit flow rate. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Method for producing titanium aluminide weld rod
Hansen, Jeffrey S.; Turner, Paul C.; Argetsinger, Edward R.
1995-01-01
A process for producing titanium aluminide weld rod comprising: attaching one end of a metal tube to a vacuum line; placing a means between said vacuum line and a junction of the metal tube to prevent powder from entering the vacuum line; inducing a vacuum within the tube; placing a mixture of titanium and aluminum powder in the tube and employing means to impact the powder in the tube to a filled tube; heating the tube in the vacuum at a temperature sufficient to initiate a high-temperature synthesis (SHS) reaction between the titanium and aluminum; and lowering the temperature to ambient temperature to obtain a intermetallic titanium aluminide alloy weld rod.
The effect of welding line heat-affected-zone on the formability of tube hydroforming process
NASA Astrophysics Data System (ADS)
ChiuHuang, Cheng-Kai; Hsu, Cheng-En; Lee, Ping-Kun
2016-08-01
Tube hydroforming has been used as a lightweight design approach to reduce CO2 emission for the automotive industry. For the high strength steel tube, the strength and quality of the welding line is very important for a successful tube hydroforming process. This paper aims to investigate the effect of the welding line's strength and the width of the heat-affected zone on the tube thinning during the hydroforming process. The simulation results show that both factors play an important role on the thickness distribution during the tube expansion.
Plasma dynamics on current-carrying magnetic flux tubes. II - Low potential simulation
NASA Technical Reports Server (NTRS)
Swift, Daniel W.
1992-01-01
The evolution of plasma in a current-carrying magnetic flux tube of variable cross section is investigated using a one-dimensional numerical simulation. The flux tube is narrow at the two ends and broad in the middle. The middle part of the flux tube is loaded with a hot, magnetically trapped population, and the two ends have a more dense, gravitationally bound population. A potential difference larger than the gravitational potential but less than the energy of the hot population is applied across the domain. The general result is that the potential change becomes distributed along the anode half of the domain, with negligible potential change on the cathode half. The potential is supported by the mirror force of magnetically trapped particles. The simulations show a steady depletion of plasma on the anode side of the flux tube. The current steadily decreases on a time scale of an ion transit time. The results may provide an explanation for the observed plasma depletions on auroral field lines carrying upward currents.
NASA Technical Reports Server (NTRS)
Sams, E. W.
1952-01-01
An investigation of forced-convection heat transfer and associated pressure drops was conducted with air flowing through electrically heated Inconel tubes having various degrees of square-thread-type roughness, an inside diameter of 1/2 inch, and a length of 24 inches. were obtained for tubes having conventional roughness ratios (height of thread/radius of tube) of 0 (smooth tube), 0.016, 0.025, and 0.037 over ranges of bulk Reynolds numbers up to 350,000, average inside-tube-wall temperatures up to 1950deg R, and heat-flux densities up to 115,000 Btu per hour per square foot. Data The experimental data showed that both heat transfer and friction increased with increase in surface roughness, becoming more pronounced with increase in Reynolds number; for a given roughness, both heat transfer and friction were also influenced by the tube wall-to-bulk temperature ratio. Good correlation of the heat-transfer data for all the tubes investigated was obtained by use of a modification of the conventional Nusselt correlation parameters wherein the mass velocity in the Reynolds number was replaced by the product of air density evaluated at the average film temperature and the so-called friction velocity; in addition, the physical properties of air were evaluated at the average film temperature. The isothermal friction data for the rough tubes, when plotted in the conventional manner, resulted in curves similar to those obtained by other investigators; that is, the curve for a given roughness breaks away from the Blasius line (representing turbulent flow in smooth tubes) at some value of Reynolds number, which decreases with increase in surface roughness, and then becomes a horizontal line (friction coefficient independent of Reynolds number). A comparison of the friction data for the rough tubes used herein indicated that the conventional roughness ratio is not an adequate measure of relative roughness for tubes having a square-thread-type element. The present data, as well as those of other investigators, were used to isolate the influence of ratios of thread height to width, thread spacing to width, and the conventional roughness ratio on the friction coefficient. A fair correlation of the friction data was obtained for each tube with heat addition when the friction coefficient and Reynolds number were defined on the basis of film properties; however, the data for each tube retained the curve characteristic of that particular roughness. The friction data for all the rough tubes could be represented by a single line for the complete turbulence region by incorporating a roughness parameter in the film correlation. No correlation was obtained for the region of incomplete turbulence.
Vortex line topology during vortex tube reconnection
NASA Astrophysics Data System (ADS)
McGavin, P.; Pontin, D. I.
2018-05-01
This paper addresses reconnection of vortex tubes, with particular focus on the topology of the vortex lines (field lines of the vorticity). This analysis of vortex line topology reveals key features of the reconnection process, such as the generation of many small flux rings, formed when reconnection occurs in multiple locations in the vortex sheet between the tubes. Consideration of three-dimensional reconnection principles leads to a robust measurement of the reconnection rate, even once instabilities break the symmetry. It also allows us to identify internal reconnection of vortex lines within the individual vortex tubes. Finally, the introduction of a third vortex tube is shown to render the vortex reconnection process fully three-dimensional, leading to a fundamental change in the topological structure of the process. An additional interesting feature is the generation of vorticity null points.
Irradiation of orderly multiline spectra from linear plasma formed by vacuum discharge capillary
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Hayasi, Yasuomi; Germer, Rudolf; Ojima, Hidenori; Takayama, Kazuyoshi; Ido, Hideaki
2005-03-01
The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments are primarily performed in order to generate intense soft x rays. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbomolecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -11.5 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 μm aluminum filter were less than 30 μs. In the spectrum measurement, we observed orderly multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. The line number decreased with corresponding decreases in the capillary length.
Ultra-fast framing camera tube
Kalibjian, Ralph
1981-01-01
An electronic framing camera tube features focal plane image dissection and synchronized restoration of the dissected electron line images to form two-dimensional framed images. Ultra-fast framing is performed by first streaking a two-dimensional electron image across a narrow slit, thereby dissecting the two-dimensional electron image into sequential electron line images. The dissected electron line images are then restored into a framed image by a restorer deflector operated synchronously with the dissector deflector. The number of framed images on the tube's viewing screen is equal to the number of dissecting slits in the tube. The distinguishing features of this ultra-fast framing camera tube are the focal plane dissecting slits, and the synchronously-operated restorer deflector which restores the dissected electron line images into a two-dimensional framed image. The framing camera tube can produce image frames having high spatial resolution of optical events in the sub-100 picosecond range.
Ultraviolet and Optical Line Profile Variations in the Spectrum of epsilon Persei
1999-11-01
hollow cathode tube via two optical Ðbers that place the comparison spec- trum above and below the stellar spectra on each exposure. An additional...of adding a new sinus- oid can be determined by the size of the decrease between AIC(N) and AIC(N ] 1). In practice, however, statistical criteria are
Patchy reconnection in the solar corona
NASA Astrophysics Data System (ADS)
Guidoni, Silvina Esther
2011-05-01
Magnetic reconnection in plasmas, a process characterized by a change in connectivity of field lines that are broken and connected to other ones with different topology, owes its usefulness to its ability to unify a wide range of phenomena within a single universal principle. There are newly observed phenomena in the solar corona that cannot be reconciled with two-dimensional or steady-state standard models of magnetic reconnection. Supra-arcade downflows (SADs) and supra-arcade downflowing loops (SADLs) descending from reconnection regions toward solar post-flare arcades seem to be two different observational signatures of retracting, isolated reconnected flux tubes with irreducible three-dimensional geometries. This dissertation describes work in refining and improving a novel model of patchy reconnection, where only a small bundle of field lines is reconnected across a current sheet (magnetic discontinuity) and forms a reconnected thin flux tube. Traditional models have not been able to explain why some of the observed SADs appear to be hot and relatively devoid of plasma. The present work shows that plasma depletion naturally occurs in flux tubes that are reconnected across nonuniform current sheets and slide trough regions of decreasing magnetic field magnitude. Moreover, through a detailed theoretical analysis of generalized thin flux tube equations, we show that the addition to the model of pressure-driven parallel dynamics, as well as temperature-dependent, anisotropic viscosity and thermal conductivity is essential for self-consistently producing gas-dynamic shocks inside reconnected tubes that heat and compress plasma to observed temperatures and densities. The shock thickness can be as long as the entire tube and heat can be conducted along tube's legs, possibly driving chromospheric evaporation. We developed a computer program that solves numerically the thin flux tube equations that govern the retraction of reconnected tubes. Simulations carried out with this program corroborate our theoretical predictions. A comparison of these simulations with fully three-dimensional magnetohydrodynamic simulations is presented to assess the validity of the thin flux tube model. We also present an observational method based on total emission measure and mean temperature to determine where in the current sheet a tube was reconnected.
NASA Astrophysics Data System (ADS)
Marchenkov, N. V.; Chukhovskii, F. N.; Blagov, A. E.
2015-03-01
The rocking curves (RCs) for Mo K α1 h Mo K α2 characteristic X-ray lines have been experimentally and theoretically studied in the nondispersive scheme of an X-ray double-crystal TPC-K diffractometer. The results of measurements and theoretical calculations of double-crystal RCs for characteristic X-rays from tubes with a molybdenum anode and different widths of slits show that a decrease in the slit width leads to an increase in the relative contribution of the Mo K α2-line RC in comparison with the intensity of the tails of the Mo K α1-line RC. It is shown that the second peak of the Mo K α2 line becomes increasingly pronounced in the tail of the Mo K α1-line RC with a decrease in the slit width. Two plane-parallel Si plates (input faces {110}, diffraction vector h <220>) were used as a monochromator crystal and a sample. The results of measuring double-crystal RCs are in good agreement with theoretical calculations.
Using Nonlinearity and Contact Lines to Control Fluid Flow in Microgravity
NASA Technical Reports Server (NTRS)
Perlin, M.; Schultz, W. W.; Bian, X.; Agarwal, M.
2002-01-01
Slug flows in a tube are affected by surface tension and contact lines, especially under microgravity. Numerical analyses and experiments are conducted of slug flows in small-diameter tubes with horizontal, inclined and vertical orientations. A PID-controlled, meter-long platform capable of following specified motions is used. An improved understanding of the contact line boundary condition for steady and unsteady contact-line motion is expected. Lastly, a direct fluid-handling method using nonlinear oscillatory motion of a tube is presented.
Two Heat-Transfer Improvements for Gas Liquefiers
NASA Technical Reports Server (NTRS)
Martin, Jerry L.
2005-01-01
Two improvements in heat-transfer design have been investigated with a view toward increasing the efficiency of refrigerators used to liquefy gases. The improvements could contribute to the development of relatively inexpensive, portable oxygen liquefiers for medical use. A description of the heat-transfer problem in a pulse-tube refrigerator is prerequisite to a meaningful description of the first improvement. In a pulse-tube refrigerator in particular, one of in-line configuration heat must be rejected from two locations: an aftercooler (where most of the heat is rejected) and a warm heat exchanger (where a small fraction of the total input power must be rejected as heat). Rejection of heat from the warm heat exchanger can be problematic because this heat exchanger is usually inside a vacuum vessel. When an acoustic-inertance tube is used to provide a phase shift needed in the pulse-tube cooling cycle, another problem arises: Inasmuch as the acoustic power in the acoustic-inertance tube is dissipated over the entire length of the tube, the gas in the tube must be warmer than the warm heat exchanger in order to reject heat at the warm heat exchanger. This is disadvantageous because the increase in viscosity with temperature causes an undesired increase in dissipation of acoustic energy and an undesired decrease in the achievable phase shift. Consequently, the overall performance of the pulse-tube refrigerator decreases with increasing temperature in the acoustic-inertance tube. In the first improvement, the acoustic-inertance tube is made to serve as the warm heat exchanger and to operate in an approximately isothermal condition at a lower temperature, thereby increasing the achievable phase shift and the overall performance of the refrigerator. This is accomplished by placing the acoustic-inertance tube inside another tube and pumping a cooling fluid (e.g., water) in the annular space between the tubes. Another benefit of this improvement is added flexibility of design to locate the warm heat-rejection components outside the vacuum vessel. The second improvement is the development of a compact radial-flow condenser characterized by a very high heat transfer coefficient and a small pressure drop.
Special wrench for B-nuts reduces torque stress in tubing
NASA Technical Reports Server (NTRS)
Stein, J. A.
1970-01-01
Gear-driven torque wrench with bearing support is used to tighten B-nut connection of partially supported fluid line with minimum stress to adjacent tubing and fittings. Wrench is useful for working with weak or brittle lines such as glass tubing.
Excitation condition analysis of guided wave on PFA tubes for ultrasonic flow meter.
Li, Xuan; Xiao, Xufeng; Cao, Li
2016-12-01
Impurity accumulation, which decreases the accuracy of flow measurement, is a critical problem when applying Z-shaped or U-shaped ultrasonic flow meters on straight PFA tubes. It can be expected that the guided wave can be used to implement flow measurement on straight PFA tubes. In this paper, the propagation of guided wave is explained by finite element simulations for the flow meter design. Conditions of guided wave generation, including the excitation frequency and the wedge structure, are studied in the simulations. The wedge is designed as a cone which is friendly to be manufactured and installed. The cone angle, the piezoelectric wafer's resonant frequency and the vibration directions are studied in the simulations. The simulations shows that the propagation of guided wave in thin PFA tubes is influenced by the piezoelectric wafers' resonant frequency and the vibration direction when the mode is on the 'water line'. Based on the results of the simulations, an experiment is conducted to verify the principles of excitation conditions, which performs flow measurement on a straight PFA tube well. Copyright © 2016 Elsevier B.V. All rights reserved.
Therapeutic effects of eustachian tube surfactant in barotitis media in guinea pigs.
Feng, Li-Ning; Chen, Wen-Xian; Cong, Rui; Gou, Lin
2003-07-01
Previous research has shown that the eustachian tube (ET) in animals and humans is lined with a substance that lowers surface tension and thus facilitates the opening of the eustachian tube and aeration of the middle ear. The aims of the present study were to observe the role of eustachian tube surfactant (ETS) on the opening of the ET and to explore the therapeutic effect of natural and artificial ETS on barotitis media (BOM). BOM was successfully established in 50 guinea pigs by simulated ascent in an altitude chamber. Subsets of the affected ears were treated by flushing with natural ETS, artificial ETS, artificial phospholipid, or saline. The effects were evaluated by measuring eustachian tube pressure opening level (POL). Other animals with BOM were treated with artificial ETS on one side and saline in the other, after which the clinical signs were observed. The POL of the saline group remained unchanged. Natural ETS decreased the POL from 11.98 to 6.11 kPa (p < 0.01); artificial ETS reduced the POL from 11.91 to 6.67 kPa (p < 0.01); there was no significant difference between the two treatments. Artificial phospholipid was less effective, decreasing POL from 11.86 to 8.61 kPa (p < 0.05). Clinical observations showed that after 1 wk of treatment with artificial ETS, the congestion in the tympanic membrane was alleviated, the hearing threshold improved, and the effusion in tympanic cavity diminished. Artificial ETS was as effective as natural ETS in facilitating the opening of eustachian tube and had definite therapeutic effects on BOM in this model.
Laser Ultrasonic System for On-Line Steel Tube Gauging
NASA Astrophysics Data System (ADS)
Monchalin, Jean-Pierre; Choquet, Marc; Padioleau, Christian; Néron, Christian; Lévesque, Daniel; Blouin, Alain; Corbeil, Christian; Talbot, Richard; Bendada, Abdelhakim; Lamontagne, Mario; Kolarik, Robert V.; Jeskey, Gerald V.; Dominik, Erich D.; Duly, Larry J.; Samblanet, Kenneth J.; Agger, Steven E.; Roush, Kenneth J.; Mester, Michael L.
2003-03-01
A laser-ultrasonic system has been installed on a seamless tubing production line of The Timken Company and is being used to measure on-line the wall thickness of tubes during processing. The seamless process consists essentially in forcing a mandrel through a hot cylindrical billet in rotation and typically results in fairly large wall thickness variations that should be minimized and controlled to respect specifications. The system includes a Q-switched Nd-YAG laser for generation of ultrasound by ablation, a long pulse very stable Nd-YAG laser for detection coupled to a confocal Fabry-Perot interferometer, a pyrometer to measure tube temperature and two laser Doppler velocimeters to measure the coordinates of the probing location at the tube surface. The laser, data acquisition and processing units are housed in a cabin off line and connected to a front coupling head located over the passing tube by optical fibers. The system has been integrated into the plant computer network and provides in real time thickness data to the plant operators. It allow much faster mill setups, has been used since its deployment for inspecting more than 100,000 tubes and has demonstrated very significant savings.
Nicholls, Colin I.
1992-07-14
An on-line product sampling apparatus and method for measuring product samples from a product stream (12) in a flow line (14) having a sampling aperture (11), includes a sampling tube (18) for containing product samples removed from flow line (14). A piston (22) removes product samples from the product stream (12) through the sampling aperture (11) and returns samples to product stream (12). A sensor (20) communicates with sample tube (18), and senses physical properties of samples while the samples are within sample tube (18). In one embodiment, sensor (20) comprises a hydrogen transient nuclear magnetic resonance sensor for measuring physical properties of hydrogen molecules.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marchenkov, N. V., E-mail: marchenkov@ns.crys.ras.ru; Chukhovskii, F. N.; Blagov, A. E.
2015-03-15
The rocking curves (RCs) for MoK{sub α1} and MoK{sub α2} characteristic X-ray lines have been experimentally and theoretically studied in the nondispersive scheme of an X-ray double-crystal TPC-K diffractometer. The results of measurements and theoretical calculations of double-crystal RCs for characteristic X-rays from tubes with a molybdenum anode and different widths of slits show that a decrease in the slit width leads to an increase in the relative contribution of the MoK{sub α2}-line RC in comparison with the intensity of the tails of the MoK{sub α1}-line RC. It is shown that the second peak of the MoK{sub α2} line becomesmore » increasingly pronounced in the tail of the MoK{sub α1}-line RC with a decrease in the slit width. Two plane-parallel Si plates (input faces (110), diffraction vector h 〈220〉) were used as a monochromator crystal and a sample. The results of measuring double-crystal RCs are in good agreement with theoretical calculations.« less
Characteristics of a capillary-discharge flash x-ray generator
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Hayasi, Yasuomi; Usuki, Tatsumi; Sato, Koetsu; Takayama, Kazuyoshi; Ido, Hideaki
2002-11-01
The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments are primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 0.2 μF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damp oscillations. The peak values of the voltage and current increased when the charging voltage was increased and their maximum values were -10.8 kV and 4.7 kV, respectively. The x-ray durations observed by a 1.6 μm aluminum filter were less than 30 μs, and we detected the aluminum characteristic x-ray intensity using a 6.8 μm aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in teh condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted greatly after pass through two slits.
77 FR 70114 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-23
... assemblies, which were caused by the fuel return line assembly rubbing against the right steering tube assembly during full rudder pedal actuation. This AD requires you to inspect the fuel return line assembly... the fuel return line assembly and both the right steering tube assembly and the airplane structure...
Pulsating flow past a tube bundle
NASA Astrophysics Data System (ADS)
Molochnikov, V. M.; Mikheev, N. I.; Vazeev, T. A.; Paereliy, A. A.
2017-11-01
Visualization of the pulsating cross-flow past the in-line and staggered tube bundles has been performed. The frequency and amplitude of forced flow pulsations and the tube pitch in the bundle varied in the experiments. The main attention was focused on the flow pattern in the near wake of the third-row tube. The most indicative regimes of flow past a tube in a bundle have been revealed depending on forced flow unsteadiness parameters. The obtained data have been generalized in the flow maps in the space of dimensionless frequency (Strouhal number, St) and relative pulsation amplitude, β, individually for the in-line and staggered tube arrangement. Three most indicative regimes of pulsating flow past the tubes in a bundle have been singled out in each flow map.
NASA Astrophysics Data System (ADS)
Moorthy, P.; Oumer, A. N.; Ishak, M.
2018-03-01
The aim of this paper is to investigate the effect of fin shapes on the performance of compact finned flat tube heat exchangers. Three types of fin shapes namely plain, wavy, and rectangular grooved fins attached to three by three arrays of flat tube banks were considered. Moreover, the tubes were deployed in in-line and staggered arrangements. In addition to the fin shapes, the air velocity and the tube inclination angles were varied and the thermal-hydraulic performance was analysed. On the other hand, the temperatures at the tube surfaces were kept constant to produce constant heat flux throughout the study. The results showed that as flowrate increases, the heat transfer increases, however, the friction factor decreases. Staggered arrangement produces higher heat transfer and friction factor than inline fin. Moreover, the rectangular fin is the best in terms of high heat transfer however the drawback of high friction factor leads the fin to have the least efficiency of all. On the other hand, plain fin had the least heat transfer performance however the highest efficiency was achieved. Therefore, plain fin should be used when efficiency is prioritized and rectangular fin when high heat transfer is desired.
Bilska-Kos, Anna; Szczepanik, Jarosław; Sowiński, Paweł
2016-10-20
Chilling stress is known to affect the water balance in plants, which often manifests itself in the decrease of the water potential in different organs. Relationships between chilling, assimilate transport and water balance are far from being understood. Although aquaporins play a key role in regulating water balance in plants, especially under stress conditions, the role of individual aquaporins in stress response remains unclear. In this report we show the specific localization within plasma membranes of one of the aquaporins (PIP2;3) in the leaves of two maize inbred lines differing in their chilling-sensitivity. This form of aquaporin has been also observed in thick-walled sieve elements - an additional type of sieve tubes of unclear function found only in monocotyledons. Moderate chilling (about 15°C) caused significant reduction of labelling in these cells accompanied by a steep decrease in the water potential in leaves of chilling-sensitive maize line. Our results suggest that both PIP2;3 and thick-walled sieve tubes may be an unknown element of the mechanism of the response of maize to cold stress. Copyright © 2016 Elsevier GmbH. All rights reserved.
50 CFR 679.24 - Gear limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... material that is brightly colored, UV-protected plastic tubing or 3/8 inch polyester line or material of an... tubing or 3/8 inch polyester line or material of an equivalent density. (iv) Snap gear streamer standard...
21 CFR 872.1850 - Lead-lined position indicator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a... dental x-ray tube and intended to aid in positioning the tube, to prevent the misfocusing of the x-rays...
High gradient lens for charged particle beam
Chen, Yu-Jiuan
2014-04-29
Methods and devices enable shaping of a charged particle beam. A dynamically adjustable electric lens includes a series of alternating a series of alternating layers of insulators and conductors with a hollow center. The series of alternating layers when stacked together form a high gradient insulator (HGI) tube to allow propagation of the charged particle beam through the hollow center of the HGI tube. A plurality of transmission lines are connected to a plurality of sections of the HGI tube, and one or more voltage sources are provided to supply an adjustable voltage value to each transmission line of the plurality of transmission lines. By changing the voltage values supplied to each section of the HGI tube, any desired electric field can be established across the HGI tube. This way various functionalities including focusing, defocusing, acceleration, deceleration, intensity modulation and others can be effectuated on a time varying basis.
1941-04-01
measured with a bank of pitot -yaw tubes-connected to a direct-reading multiple-tube manometer. The- bank of pitot -yaw tubes was so mounted as- to...neutral and deflected 60°. These Surveys were made on a cross-tunnel line 2.26 inches above the fuselage center line, and the pitot -yaw tubes were...Langley Field-, 7a-., January 30, 1941. NACA Technical Note So. 804 17 REFERENCES 1. Pearson, Henry A., and Jones, Robert T. : Theoretical
Textures and traction: how tube-dwelling polychaetes get a leg up
Merz, Rachel Ann
2015-01-01
By controlling the traction between its body and the tube wall, a tube-dwelling polychaete can move efficiently from one end of its tube to the other, brace its body during normal functions (e.g., ventilation and feeding), and anchor within its tube avoiding removal by predators. To examine the potential physical interaction between worms and the tubes they live in, scanning electron microscopy was used to reveal and quantify the morphology of worm bodies and the tubes they produce for species representing 13 families of tube-dwelling polychaetes. In the tubes of most species there were macroscopic or nearly macroscopic (∼10 μm–1 mm) bumps or ridges that protruded slightly into the lumen of the tube; these could provide purchase as a worm moves or anchors. At this scale (∼10 μm-1 mm), the surfaces of the chaetal heads that interact with the tube wall were typically small enough to fit within spaces between these bumps (created by the inward projection of exogenous materials incorporated into the tube wall) or ridges (made by secretions on the interior surface of the tube). At a finer scale (0.01–10 μm), there was a second overlap in size, usually between the dentition on the surfaces of chaetae that interact with the tube walls and the texture provided by the secreted strands or microscopic inclusions of the inner linings. These linings had a surprising diversity of micro-textures. The most common micro-texture was a “fabric” of secreted threads, but there were also orderly micro-ridges, wrinkles, and rugose surfaces provided by microorganisms incorporated into the inner tube lining. Understanding the fine structures of tubes in conjunction with the morphologies of the worms that build them gives insight into how tubes are constructed and how worms live within them. PMID:25834379
Weng, Chih-Chiang; Liao, Juinn-Der; Chen, Hsin-Hung; Lin, Tung-Yi; Huang, Chih-Ling
2011-09-01
An aqueous solution containing Escherichia coli can be completely inactivated within a short treatment time using a capillary-tube-based oxygen/argon micro-plasma source. A capillary-tube-based oxygen/argon micro-plasma system with a hollow inner electrode was ignited by a 13.56 MHz radio frequency power supply with a matching network and characterised by optical emission spectroscopy. An aqueous solution containing E. coli was then treated at various the working distances, plasma exposure durations, and oxygen ratios in argon micro-plasma. The treated bacteria were then assessed and qualitatively investigated. The morphologies of treated bacteria were examined using a scanning electron microscope (SEM). In the proposed oxygen/argon micro-plasma system, the intensities of the main emission lines of the excited species, nitric oxide (NO), hydrated oxide (OH), argon (Ar), and atomic oxygen (O), fluctuated with the addition of oxygen to argon micro-plasma. Under a steady state of micro-plasma generation, the complete inactivation of E. coli in aqueous solution was achieved within 90 s of argon micro-plasma exposure time with a working distance of 3 mm. SEM micrographs reveal obvious morphological damage to the treated E. coli. The addition of oxygen to argon micro-plasma increased the variety of O-containing excited species. At a given supply power, the relative intensities of the excited species, NO and OH, correlated with the ultraviolet (UV) intensity, decreased. For the proposed capillary-tube-based micro-plasma system with a hollow inner electrode, the oxygen/argon micro-plasma source is efficient in inactivating E. coli in aqueous solution. The treatment time required for the inactivation process decreases with decreasing working distance or the increasing synthesised effect of reactive species and UV intensity.
Thanasai, Jongkonnee; Limpaiboon, Temduang; Jearanaikoon, Patcharee; Sripa, Banchob; Pairojkul, Chawalit; Tantimavanich, Srisurang; Miwa, Masanao
2010-01-01
AIM: To evaluate the role of thymidine phosphorylase (TP) in cholangiocarcinoma using small interfering RNA (siRNA). METHODS: A human cholangiocarcinoma-derived cell line KKU-M139, which has a naturally high level of endogenous TP, had TP expression transiently knocked down using siRNA. Cell growth, migration, in vitro angiogenesis, apoptosis, and cytotoxicity were assayed in TP knockdown and wild-type cell lines. RESULTS: TP mRNA and protein expression were decreased by 87.1% ± 0.49% and 72.5% ± 3.2%, respectively, compared with control cells. Inhibition of TP significantly decreased migration of KKU-M139, and suppressed migration and tube formation of human umbilical vein endothelial cells. siRNA also reduced the ability of TP to resist hypoxia-induced apoptosis, while suppression of TP reduced the sensitivity of KKU-M139 to 5-fluorouracil. CONCLUSION: Inhibition of TP may be beneficial in decreasing angiogenesis-dependent growth and migration of cholangiocarcinoma but may diminish the response to 5-fluorouracil chemotherapy. PMID:20355241
Recurrent white thrombi formation in hemodialysis tubing: a case report.
Sathe, Kiran P; Yeo, Wee-Song; Liu, Isaac Desheng; Ekambaram, Sudha; Azar, Mohammed; Yap, Hui-Kim; Ng, Kar-Hui
2015-01-15
While the appearance of red clots in the dialyzer is a common phenomenon in every hemodialysis unit, the occurrence of white thrombi in the tubing is relatively rare. We describe an adolescent male with recurrent white thrombi formation in the hemodialysis tubing. This patient had chronic renal failure from focal segmental glomerulosclerosis, but was no longer nephrotic at the time of the thrombi formation. He had a history of recurrent thrombosis of his vascular access. However, no pro-thrombotic risk factors could be identified. White particulate matter, measuring 1 to 3mm in size, and adherent to the arterial and venous blood tubing lines was found during the rinse back of a hemodialysis session. This was associated with a 60% decrease in his platelet count. Light microscopic examination of the deposits revealed the presence of platelet aggregates. He subsequently developed thrombosis of his arteriovenous graft six hours later. The white thrombi recurred at the next dialysis session, as well as six months later. These episodes occurred regardless of the type of dialysis machine or tubing, and appeared to resolve with an increase in heparin dose. Recurrent white thrombi formation can occur in the hemodialysis tubing of a patient with no identifiable pro-thrombotic factors. The white thrombi may be a harbinger of arteriovenous graft thrombosis and may be prevented by an increase in heparin dose.
Porteous, Nuala; Luo, Jie; Hererra, Monica; Schoolfield, John; Sun, Yuyu
2011-01-01
This study examined bacterial growth and type on biofilm-controlling dental unit waterline (DUWL) tubing (T) and control manufacturer's tubing (C) in a laboratory DUWL model using ultrapure source water that was cycled through the lines. Sections of tubing lines were detached and examined for biofilm growth using SEM imaging at six sampling periods. Bacteria from inside surfaces of T and C, source unit, and reservoir were cultured and enumerated. At six months, organisms were molecularly identified from the alignment matches obtained from the top three BLAST searches for the 16S region. There was a 1–3 log increase in organism growth in a clean, nonsterile reservoir within an hour. Biofilm was established on the inside surfaces of C within three weeks, but not on T. Proteobacteria, and Sphingomonas spp. were identified in the source reservoir and C line, and a variation of the genera was found in T line. PMID:22220171
Severson, Wayne J.
1976-01-01
The overflow line for the reactor vessel of a liquid-metal-cooled nuclear reactor includes means for establishing and maintaining a continuous bleed flow of coolant amounting to 5 to 10% of the total coolant flow through the overflow line to prevent thermal shock to the overflow line when the reactor is restarted following a trip. Preferably a tube is disposed concentrically just inside the overflow line extending from a point just inside the reactor vessel to an overflow tank and a suction line is provided opening into the body of liquid metal in the reactor vessel and into the annulus between the overflow line and the inner tube.
Paramecium swimming in capillary tube
NASA Astrophysics Data System (ADS)
Jana, Saikat; Um, Soong Ho; Jung, Sunghwan
2012-04-01
Swimming organisms in their natural habitat need to navigate through a wide range of geometries and chemical environments. Interaction with boundaries in such situations is ubiquitous and can significantly modify the swimming characteristics of the organism when compared to ideal laboratory conditions. We study the different patterns of ciliary locomotion in glass capillaries of varying diameter and characterize the effect of the solid boundaries on the velocities of the organism. Experimental observations show that Paramecium executes helical trajectories that slowly transition to straight lines as the diameter of the capillary tubes decreases. We predict the swimming velocity in capillaries by modeling the system as a confined cylinder propagating longitudinal metachronal waves that create a finite pressure gradient. Comparing with experiments, we find that such pressure gradient considerations are necessary for modeling finite sized ciliary organisms in restrictive geometries.
Flux transfer events: Reconnection without separators. [magnetopause
NASA Technical Reports Server (NTRS)
Hesse, M.; Birn, J.; Schindler, K.
1989-01-01
A topological analysis of a simple model magnetic field of a perturbation at the magnetopause modeling an apparent flux transfer event is presented. It is shown that a localized perturbation at the magnetopause can in principle open a closed magnetosphere by establishing magnetic connections across the magnetopause. Although the model field exhibits neutral points, these are not involved in the magnetic connection of the flux tubes. The topological substructure of a localized perturbation is analyzed in a simpler configuration. The presence of both signs of the magnetic field component normal to the magnetopause leads to a linkage of topologically different flux tubes, described as a flux knot, and a filamentary substructure of field lines of different topological types which becomes increasingly complicated for decreasing magnetic shear at the magnetopause.
Leakproof Swaged Joints in Thin-Wall Tubing
NASA Technical Reports Server (NTRS)
Stuckenberg, F. H.; Crockett, L. K.; Snyder, W. E.
1986-01-01
Tubular inserts reinforce joints, reducing incidence of leaks. In new swaging technique, tubular inserts placed inside ends of both tubes to be joined. Made from thicker-wall tubing with outside diameter that matches inside diameter of thin tubing swaged, inserts support tube ends at joint. They ensure more uniform contact between swage fitting and tubing. New swaging technique developed for Al/Ti/V-alloy hydraulic supply lines.
Coolant monitoring apparatus for nuclear reactors
Tokarz, Richard D.
1983-01-01
A system for monitoring coolant conditions within a pressurized vessel. A length of tubing extends outward from the vessel from an open end containing a first line restriction at the location to be monitored. The flowing fluid is cooled and condensed before passing through a second line restriction. Measurement of pressure drop at the second line restriction gives an indication of fluid condition at the first line restriction. Multiple lengths of tubing with open ends at incremental elevations can measure coolant level within the vessel.
77 FR 50054 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-20
... rubbing against the right steering tube assembly during full rudder pedal actuation. This proposed AD would require you to inspect the fuel return line assembly for chafing; replace the fuel return line... right steering tube assembly and the airplane structure; and adjustment as necessary. We are proposing...
77 FR 72250 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... rubbing against the right steering tube assembly during rudder pedal actuation. This proposed AD would require you to install the forward and aft fuel return line support clamps and brackets; inspect for a minimum clearance between the fuel return line assembly and the steering tube assembly and clearance...
Investigation of heat transfer of tube line of staggered tube bank in two-phase flow
NASA Astrophysics Data System (ADS)
Jakubcionis, Mindaugas
2015-06-01
This article presents the results of experimental investigation of heat transfer process, carried out using the model of heat exchanger. Two-phase statically stable foam flow was used as a heat transfer fluid. Heat exchanger model consisted of staggered tube bank. Experimental results are presented with the focus on influence of tube position in the line of the bank, volumetric void component and velocity of gas component of the foam. The phenomena of liquid draining in cellular foam flow and its influence on heat transfer rate has also been discussed. The experimental results have been generalized by relationship between Nusselt, Reynolds and Prandtl numbers.
Novel Biophysical Marker of Aggressive Prostate Cancer Cells
2013-06-01
needle. Once the entire contents of the syringe is passed through the needle (considered one passage) and (B) collected in a 15 mL polypropylene tube cut ...tissue culture media for the cell line analyzed unless otherwise indicated. 4 mL of suspension is placed into a 14 mL polypropylene round-bottom tubes...BD Falcon #352059) cut down to the 5 mL line (collection tube) and loaded into a 5 mL syringe (BD Biosciences #309603) by slowly drawing up the cells
Standardizing adult tracheostomy tube styles: what is the clinical and cost-effective impact?
Crimlisk, Janet T; O'Donnell, Charles; Grillone, Gregory A
2006-01-01
Tracheostomy tubes are made of a variety of materials, components, and styles. In a recent merger of our hospitals, we noted a large assortment of tubes available for clinicians. The different tubes resulted in complaints from staff, which included confusion, delays in obtaining preferred tubes, and inconsistent shelf stock. A multidisciplinary task force was formed to recommend standardizing the styles of tracheostomy tubes. A comparison of tracheotomy procedures, tracheostomy tube usage, and tube costs were done 6 months before and 6 months after the standardization. The number of tube styles decreased from 9 to 4; specialty extra-long tubes decreased from 3 to 2. There were no cost savings in standardizing the tracheostomy tubes.
Model development of supersonic trough wind with shocks
NASA Technical Reports Server (NTRS)
Grebowsky, J. M.
1972-01-01
The time dependent one dimensional hydrodynamic equations describe the evolution of the thermal plasma flow along closed magnetic field lines outside of the plasmasphere. The convection of the supersonic polar wind onto a closed fieldline results in the assumed formation of collisionless plasma shocks. These shocks move earthward as the field line with its frozen-in plasma remains fixed or contracts with time to smaller L coordinates. The high equatorial plasma temperature (of the order of electron volts) produced by the shock process decreases with time if the flow is isothermal but it will increase if the contraction is under adiabatic conditions. Assuming adiabaticity a peak in the temperature forms at the equator in conjunction with a depression in the ion density. After an initial contraction, if the flux tube drifts to higher L coordinates the direction of the shock motion can be reversed so that the supersonic region will expand along the field line towards the state characterizing the supersonic polar wind. A rapid expansion will lower the equatorial density while the temperature decreases with time under adiabatic but not isothermal conditions.
Tubing Cutter is Activated Hydraulically
NASA Technical Reports Server (NTRS)
Mcsmith, D. G.; Richardson, J. I.
1983-01-01
Hydraulically-actuated tubing cutter severs tubing when operator squeezes handle grip. "Gooseneck" extension enables cutter to be used in areas where accessiblity is limited. Cutter has potential as flight-line tool and is useful in automobile and fire rescue work.
Gas insulated transmission line having low inductance intercalated sheath
Cookson, Alan H.
1978-01-01
A gas insulated transmission line including an outer sheath, an inner conductor disposed within the outer sheath, and an insulating gas between the inner conductor and the outer sheath. The outer sheath comprises an insulating tube having first and second ends, and having interior and exterior surfaces. A first electrically conducting foil is secured to the interior surface of the insulating tube, is spirally wound from one tube end to the second tube end, and has a plurality of overlapping turns. A second electrically conducting foil is secured to the exterior surface of the insulating tube, and is spirally wound in the opposite direction from the first electrically conducting foil. By winding the foils in opposite directions, the inductances within the intercalated sheath will cancel each other out.
Note: Development of target changeable palm-top pyroelectric x-ray tube
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imashuku, Susumu; Kawai, Jun
2012-01-15
A target changeable palm-top size x-ray tube was realized using pyroelectric crystal and detachable vacuum flanges. The target metals can be exchanged easily by attaching them on the brass stage with carbon tape. When silver and titanium palates (area: 10 mm{sup 2}) were used as targets, silver L{alpha} and titanium K lines were clearly observed by bombarding electrons on the targets for 90 s. The intensities were the same or higher than those of previously reported pyroelectric x-ray tubes. Chromium, iron, nickel, copper, and zinc K lines in the x-ray tube (stainless steel and brass) disappeared by replacing the brassmore » stage and the stainless steel vacuum flange with a carbon stage and a glass tube, respectively.« less
Effects of the Canopy and Flux Tube Anchoring on Evaporation Flow of a Solar Flare
NASA Astrophysics Data System (ADS)
Unverferth, John; Longcope, Dana
2018-06-01
Spectroscopic observations of flare ribbons typically show chromospheric evaporation flows, which are subsonic for their high temperatures. This contrasts with many numerical simulations where evaporation is typically supersonic. These simulations typically assume flow along a flux tube with a uniform cross-sectional area. A simple model of the magnetic canopy, however, includes many regions of low magnetic field strength, where flux tubes achieve local maxima in their cross-sectional area. These are analgous to a chamber in a flow tube. We find that one-third of all field lines in a model have some form of chamber through which evaporation flow must pass. Using a one-dimensional isothermal hydrodynamic code, we simulated supersonic flow through an assortment of chambers and found that a subset of solutions exhibit a stationary standing shock within the chamber. These shocked solutions have slower and denser upflows than a flow through a uniform tube would. We use our solution to construct synthetic spectral lines and find that the shocked solutions show higher emission and lower Doppler shifts. When these synthetic lines are combined into an ensemble representing a single canopy cell, the composite line appears slower, even subsonic, than expected due to the outsized contribution from shocked solutions.
The Current Driven Kink Instability and its Relationship to Delta-Spot Active Regions
NASA Astrophysics Data System (ADS)
Linton, Mark George
The current driven kink instability may be the cause of both the unusual morphology of solar δ-spot active regions and the tendency of these regions to be significantly more flare active than most active regions. We investigate the current driven kink instability of flux tubes in the solar interior both with a linear stability analysis and with nonlinear MHD simulations. The linear analysis shows that there is a critical twist, which depends on the axial magnetic field profile, that a flux tube needs to become kink unstable. This critical twist decreases as the tube expands, so twisted flux tubes will become increasingly unstable as they rise through the convection zone. The nonlinear simulations show that a twisted tube excited by a single unstable kink mode will evolve to a helical equilibrium state. The emergence through the photosphere of such a kinked tube would create an active region which was tilted with respect to Hale's law and which would rotate as it evolved, as δ-spots are observed to do. We then find that, when excited by multiple unstable kink modes, highly twisted flux tubes develop concentrated kinks. These concentrated kinks would produce more of the observed characteristics of δ-spot active regions. They would create active regions which, in addition to emerging tilted and then rotating, would remain compact as they evolved, and develop strong shear along their magnetic neutral line. Finally, we find that a strong concentrated kink develops a current sheet at which the magnetic field reconnects, which may be the cause of the high flare activity of δ-spots.
Some considerations on instability of combined loaded thin-walled tubes with a crack
NASA Astrophysics Data System (ADS)
Shariati, M.; Akbarpour, A.
2016-05-01
Instability of a thin-walled stainless steel tube with a crack-shaped defect under combined loading is studied in this paper. Furthermore, the effects of the tube length, crack orientation, and crack length on the buckling behavior of tubes are investigated. The behavior of tubes subjected to combined is analyzed by using the finite element method (by Abaqus software). For cracked tubes with a fixed thickness, the buckling load decreases as the tube length and the ratio of the tube length to its diameter increase. Moreover, the buckling load of cracked tubes under combined loading also decreases with increasing crack length.
Direct measurements of flux tube inclinations in solar plages.
NASA Astrophysics Data System (ADS)
Bernasconi, P. N.; Keller, C. U.; Povel, H. P.; Stenflo, J. O.
1995-10-01
Observations of the full Stokes vector in three spectral lines indicate that flux tubes in solar plages have an average inclination in the photosphere of 14^o^ with respect to the local vertical. Most flux tubes are inclined in the eastwards direction, i.e., opposite to the solar rotation. We have recorded the Stokes vector of the FeI 5247.1A, FeI 5250.2A, and FeI 5250.7A lines in nine different plages with the polarization-free 20cm Zeiss coronagraph at the Arosa Astrophysical Observatory of ETH Zuerich. The telescope has been modified for solar disk observations. The chosen spectral lines are particularly sensitive to magnetic field strength and temperature. To determine the field strength and geometry of the flux tubes in the observed plages we use an inversion code that numerically solves the radiative transfer equations and derives the emergent Stokes profiles for one-dimensional model atmospheres consisting of a flux tube and its surrounding non-magnetic atmosphere. Our results confirm earlier indirect estimates of the inclination of the magnetic fields in plages.
Study of argon-oxygen flowing afterglow
NASA Astrophysics Data System (ADS)
Mazánková, V.; Trunec, D.; Navrátil, Z.; Raud, J.; Krčma, F.
2016-06-01
The reaction kinetics in argon-oxygen flowing afterglow (post-discharge) was studied using NO titration and optical emission spectroscopy. The flowing DC post-discharge in argon-oxygen mixture was created in a quartz tube at the total gas pressure of 1000 Pa and discharge power of 90 W. The O(3P) atom concentration was determined by NO titration at different places along the flow tube. The optical emission spectra were also measured along the flow tube. Argon spectral lines, oxygen lines at 777 nm and 844.6 nm and atmospheric A-band of {{\\text{O}}2} were identified in the spectra. Rotational temperature of {{\\text{O}}2} was determined from the oxygen atmospheric A-band and also the outer wall temperature of the flow tube was measured by a thermocouple and by an IR thermometer. A zero-dimensional kinetic model for the reactions in the afterglow was developed. This model allows the time dependencies of particle concentrations and of gas temperature to be calculated. The wall recombination probability for O(3P) atoms {γ\\text{O≤ft(\\text{P}\\right)}}=≤ft(1.63+/- 0.06\\right)× {{10}-3} and wall deactivation probability for {{\\text{O}}2} (b {{}1}Σ\\text{g}+ ) molecules {γ{{\\text{O}2}≤ft(\\text{b}\\right)}}=≤ft(1.7+/- 0.1\\right)× {{10}-3} were determined from the fit of model results to experimental data. Sensitivity analysis was applied for the analysis of kinetic model in order to reveal the most important reactions in the model. The calculated gas temperature increases in the afterglow and then decreases at later afterglow times after reaching the maximum. This behavior is in good agreement with the spatial rotational temperature dependence. A similar trend was also observed at outer wall temperature measurement.
Boiler Tube Corrosion Characterization with a Scanning Thermal Line
NASA Technical Reports Server (NTRS)
Cramer, K. Elliott; Jacobstein, Ronald; Reilly, Thomas
2001-01-01
Wall thinning due to corrosion in utility boiler water wall tubing is a significant operational concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. Unfortunately, ultrasonic inspection is very manpower intense and slow. Therefore, thickness measurements are typically taken over a relatively small percentage of the total boiler wall and statistical analysis is used to determine the overall condition of the boiler tubing. Other inspection techniques, such as electromagnetic acoustic transducer (EMAT), have recently been evaluated, however they provide only a qualitative evaluation - identifying areas or spots where corrosion has significantly reduced the wall thickness. NASA Langley Research Center, in cooperation with ThermTech Services, has developed a thermal NDE technique designed to quantitatively measure the wall thickness and thus determine the amount of material thinning present in steel boiler tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed and accuracy for large structures such as boiler water walls. A theoretical basis for the technique will be presented to establish the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of the application of this technology to actual water wall tubing samples and in-situ inspections will be presented.
Explosive instability and erupting flux tubes in a magnetized plasma
Cowley, S. C.; Cowley, B.; Henneberg, S. A.; Wilson, H. R.
2015-01-01
The eruption of multiple flux tubes in a magnetized plasma is proposed as a mechanism for explosive release of energy in plasmas. A significant fraction of the linearly stable isolated flux tubes are shown to be metastable in a box model magnetized atmosphere in which ends of the field lines are embedded in conducting walls. The energy released by destabilizing such field lines can be a large proportion of the gravitational energy stored in the system. This energy can be released in a fast dynamical time. PMID:26339193
Recirculation bubbler for glass melter apparatus
Guerrero, Hector [Evans, GA; Bickford, Dennis [Folly Beach, SC
2007-06-05
A gas bubbler device provides enhanced recirculation of molten glass within a glass melter apparatus. The bubbler device includes a tube member disposed within a pool of molten glass contained in the melter. The tube member includes a lower opening through which the molten glass enters and upper slots disposed close to (above or below) the upper surface of the pool of molten glass and from which the glass exits. A gas (air) line is disposed within the tube member and extends longitudinally thereof. A gas bubble distribution device, which is located adjacent to the lower end of the tube member and is connected to the lower end of the gas line, releases gas through openings therein so as to produce gas bubbles of a desired size in the molten glass and in a distributed pattern across the tube member.
Coaxial tube array space transmission line characterization
NASA Technical Reports Server (NTRS)
Switzer, Colleen A.; Bents, David J.
1987-01-01
The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.
Coaxial tube array space transmission line characterization
NASA Astrophysics Data System (ADS)
Switzer, Colleen A.; Bents, David J.
The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.
NASA Technical Reports Server (NTRS)
Cramer, K. Elliott; Winfree, William P.
2000-01-01
Wall thinning in utility boiler waterwall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used lor inspection of these tubes. This technique has proved to be very labor intensive and slow. This has resulted in a "spot check" approach to inspections, making thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source, coupled with this analysis technique, represents a significant improvement in the inspection speed for large structures such as boiler waterwalls while still providing high-resolution thickness measurements. A theoretical basis for the technique will be presented thus demonstrating the quantitative nature of the technique. Further, results of laboratory experiments on flat Panel specimens with fabricated material loss regions will be presented.
Lagrangian transport near perturbed periodic lines in three-dimensional unsteady flows
NASA Astrophysics Data System (ADS)
Speetjens, Michel
2015-11-01
Periodic lines formed by continuous strings of periodic points are key organizing entities in the Lagrangian flow topology of certain three-dimensional (3D) time-periodic flows. Such lines generically consist of elliptic and/or hyperbolic points and thus give rise to 3D flow topologies made up of families of concentric closed trajectories embedded in chaotic regions. Weak perturbation destroys the periodic lines and causes said trajectories to coalesce into families of concentric tubes. However, emergence of isolated periodic points near the disintegrating periodic lines and/or partitioning of the original lines into elliptic and hyperbolic segments interrupt the tube formation. This yields incomplete tubes that interact with the (chaotic) environment through their open ends, resulting in intricate and essentially 3D flow topologies These phenomena have been observed in various realistic flows yet the underlying mechanisms are to date only partially understood. This study deepens insight into the (perturbed) Lagrangian dynamics of these flows by way of a linearized representation of the equations of motion near the periodic lines. Predictions on the basis of this investigation are in full (qualitative) agreement with observed behavior in the actual flows
NASA Technical Reports Server (NTRS)
Cramer, K. Elliott; Winfree, William P.
2000-01-01
Localized wall thinning due to corrosion in utility boiler water-wall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. This technique has proven to be very manpower and time intensive. This has resulted in a spot check approach to inspections, documenting thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed for large structures such as boiler water-walls. A theoretical basis for the technique will be presented which explains the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of applying this technology to actual water-wall tubing samples and in situ inspections will be presented.
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer—Health Professional Version
Ovarian epithelial, fallopian tube, and peritoneal cancers are diseases in which malignant cells form in the tissue covering the ovary, lining the fallopian tube, or peritoneum. Find evidence-based information on ovarian cancer treatment, causes and prevention, screening, research, genetics and statistics.
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... The device consists of a powered suction pump (containing a microbial filter on the exhaust and a microbial in-line filter in the connecting tubing between the collection bottle and the safety trap), collection bottle, cannula, and connecting tube. The microbial filters, tubing, collection bottle, and...
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... The device consists of a powered suction pump (containing a microbial filter on the exhaust and a microbial in-line filter in the connecting tubing between the collection bottle and the safety trap), collection bottle, cannula, and connecting tube. The microbial filters, tubing, collection bottle, and...
An Ichor-dependent apical extracellular matrix regulates seamless tube shape and integrity
Rosa, Jeffrey B.; Metzstein, Mark M.
2018-01-01
During sprouting angiogenesis in the vertebrate vascular system, and primary branching in the Drosophila tracheal system, specialized tip cells direct branch outgrowth and network formation. When tip cells lumenize, they form subcellular (seamless) tubes. How these seamless tubes are made, shaped and maintained remains poorly understood. Here we characterize a Drosophila mutant called ichor (ich), and show that ich is essential for the integrity and shape of seamless tubes in tracheal terminal cells. We find that Ich regulates seamless tubulogenesis via its role in promoting the formation of a mature apical extracellular matrix (aECM) lining the lumen of the seamless tubes. We determined that ich encodes a zinc finger protein (CG11966) that acts, as a transcriptional activator required for the expression of multiple aECM factors, including a novel membrane-anchored trypsin protease (CG8213). Thus, the integrity and shape of seamless tubes are regulated by the aECM that lines their lumens. PMID:29309404
The structure, energy balance, and winds of cool stars
NASA Technical Reports Server (NTRS)
Linsky, J. L.
1982-01-01
The phenomena associated with magnetic fields in the Sun are summarized and it is shown that similar phenomena occur in cool stars. High dispersion spectra are providing unique information concerning densities, atmospheric extension, and emission line widths. A recent unanticipated discovery is that the transition lines are redshifted (an antiwind) in beta Dra (G2 Ib) and perhaps other stars. This is interpreted as indicating downflows in closed magnetic flux tubes as are seen in the solar flux tubes above sunspots. The G and K giants and supergiants are classified as active stars, quiet stars, or hybrid stars depending on whether their atmospheres are dominated by closed magnetic flux tubes, open field geometries, or a predominately open geometry with a few closed flux tubes embedded.
Origami tubes with reconfigurable polygonal cross-sections.
Filipov, E T; Paulino, G H; Tachi, T
2016-01-01
Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings.
Origami tubes with reconfigurable polygonal cross-sections
Filipov, E. T.; Paulino, G. H.; Tachi, T.
2016-01-01
Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings. PMID:26997894
ZHAO, BING; HU, MENGCAI
2013-01-01
Gallic acid is a trihydroxybenzoic acid, also known as 3,4,5-trihydroxybenzoic acid, which is present in plants worldwide, including Chinese medicinal herbs. Gallic acid has been shown to have cytotoxic effects in certain cancer cells, without damaging normal cells. The objective of the present study was to determine whether gallic acid is able to inhibit human cervical cancer cell viability, proliferation and invasion and suppress cervical cancer cell-mediated angiogenesis. Treatment of HeLa and HTB-35 human cancer cells with gallic acid decreased cell viability in a dose-dependent manner. BrdU proliferation and tube formation assays indicated that gallic acid significantly decreased human cervical cancer cell proliferation and tube formation in human umbilical vein endothelial cells, respectively. Additionally, gallic acid decreased HeLa and HTB-35 cell invasion in vitro. Western blot analysis demonstrated that the expression of ADAM17, EGFR, p-Akt and p-Erk was suppressed by gallic acid in the HeLa and HTB-35 cell lines. These data indicate that the suppression of ADAM17 and the downregulation of the EGFR, Akt/p-Akt and Erk/p-Erk signaling pathways may contribute to the suppression of cancer progression by Gallic acid. Gallic acid may be a valuable candidate for the treatment of cervical cancer. PMID:24843386
DISTRIBUTED AMPLIFIER INCORPORATING FEEDBACK
Bell, P.R. Jr.
1958-10-21
An improved distributed amplifier system employing feedback for stabilization is presented. In accordance with the disclosed invention, a signal to be amplified is applled to one end of a suitable terminated grid transmission line. At intervals along the transmission line, the signal is fed to stable, resistance-capacitance coupled amplifiers incorporating feedback loops therein. The output current from each amplifier is passed through an additional tube to minimize the electrostatic capacitance between the tube elements of the last stage of the amplifier, and fed to appropriate points on an output transmission line, similar to the grid line, but terminated at the opposite (input) end. The output taken from the unterminated end of the plate transmission line is proportional to the input voltage impressed upon the grid line.
Exogenous bacterial contamination of donor blood.
Rock, G; Westwood, J C
1977-05-07
The Canadian Red Cross blood transfusion service has followed a set protocol for phlebotomy and collection of a unit of blood. Recent requirements for automated testing have necessitated that a second tube of blood be obtained from the blood line following collection of the unit. Evaluation of the techniques used, however, has indicated the possibility of bacterial contamination from the skin of donors, from insertion of the needle through an unsterile rubber stopper, and through backflow from a nonsterile vacuum tube. To test these possibilities swabs were taken from skin and stoppers of vacuum tubes. Further, vacuum tubes were deliberately contaminated with Escherichia coli. The normal sampling procedure, which involves stripping the donor line to refill and mix the blood, was then followed. This resulted in contamination of the segments and even the blood bag. These findings led to modification of the standard bleeding technique, whereby stripping was eliminated and sterile vacuum tubes were to be used at all times.
Nagamine, Shuji; Fujibuchi, Toshioh; Umezu, Yoshiyuki; Himuro, Kazuhiko; Awamoto, Shinichi; Tsutsui, Yuji; Nakamura, Yasuhiko
2017-03-01
In this study, we estimated the ambient dose equivalent rate (hereafter "dose rate") in the fluoro-2-deoxy-D-glucose (FDG) administration room in our hospital using Monte Carlo simulations, and examined the appropriate medical-personnel locations and a shielding method to reduce the dose rate during FDG injection using a lead glass shield. The line source was assumed to be the FDG feed tube and the patient a cube source. The dose rate distribution was calculated with a composite source that combines the line and cube sources. The dose rate distribution was also calculated when a lead glass shield was placed in the rear section of the lead-acrylic shield. The dose rate behind the automatic administration device decreased by 87 % with respect to that behind the lead-acrylic shield. Upon positioning a 2.8-cm-thick lead glass shield, the dose rate behind the lead-acrylic shield decreased by 67 %.
Tube-in-tube thermophotovoltaic generator
Ashcroft, John; Campbell, Brian; DePoy, David
1998-01-01
A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.
Mechanism of tonal noise generation from circular cylinder with spiral fin
NASA Astrophysics Data System (ADS)
Yamashita, Ryo; Hayashi, Hidechito; Okumura, Tetsuya; Hamakawa, Hiromitsu
2014-12-01
The pitch of the spiral finned tube influences seriously to the acoustic resonance in the heat exchanger. In this research, the flow characteristics in relating to the aeolian tone from the finned cylinder are studied by the numerical simulation. It is observed that the tonal noise generated from the finned tube at two pitch spaces. The ratio of the fin pitch to the cylinder diameter is changed at 0.11 and 0.27. The tone level increases and the frequency decreases with the pitch shorter. The separation flow from the cylinder generates the span-wise vortices, Karman vortices, and the separation flow from the fin generates the stream-wise vortices. When the fin pitch ratio is small, the stream-wise vortices line up to span-wise and become weak rapidly. Only the Karman vortices are remained and integrate in span. So the Karman vortex became large. This causes the low frequency and the large aeolian tone.
Reduction of Secondary Flow in Inclined Orifice Pulse Tubes by Addition of DC Flow
NASA Astrophysics Data System (ADS)
Shiraishi, M.; Fujisawa, Y.; Murakami, M.; Nanako, A.
2004-06-01
The effect of using a second orifice valve to reduce convective losses caused by gravity-driven convective secondary flow in inclined orifice pulse tube refrigerators was investigated. The second orifice valve was installed between a reservoir and a low-pressure line of a compressor. When the valve was open, an additional DC flow directed to the hot end of the refrigerator was generated to counterbalance the convective secondary flow in the core region by opening the valve. Experimental results indicated that with increasing additional DC flow to an optimum level, the convective secondary flow decreased and the cooling performance improved, although further increase of the DC flow over the level caused the cooling performance to degrade. In summary, the second orifice valve was effective in reducing both the convective losses without affecting the cooling performance at an inclination angle < 70° where convective losses were negligibly small.
Aircraft Hydraulic Systems Dynamic Analysis Component Data Handbook
1980-04-01
82 13. QUINCKE TUBE ...................................... 85 14. 11EAT EXCHANGER ............. ................... 90...Input Parameters ....... ........... .7 61 )uincke Tube Input Parameters with Hole Locat ions 87 62 "rototype Quincke Tube Data ........... 89 6 3 Fo-,:ed...Elasticity (Line 3) PSI 1.6E7 FIGURE 58 HSFR INPUT DATA FOR PULSCO TYPE ACOUSTIC FILTER 84 13. QUINCKE TUBE A means to dampen acoustic noise at resonance
Outplanting long tubes with the expandable stinger: A new treatment for riparian restoration
David E. Steinfeld; Thomas D. Landis; Dan Culley
2002-01-01
Long tubes are a new stock type developed specifically for restoration of challenging sites such as disturbed riparian areas. Constructed out of polyvinyl chloride plastic pipe, long tubes have a Vexar lining to promote good root growth and easier extraction. The expandable stinger is a new invention that was developed to outplant long tubes. The stinger is attached to...
2017-08-21
Borderline Ovarian Mucinous Tumor; Ovarian Mucinous Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer
Feasiblity study for a 34 GHz (Ka band) gyroamplifier
NASA Technical Reports Server (NTRS)
Stone, D. S.; Bier, R. E.; Caplan, M.; Huey, H. E.; Pirkle, D. R.; Robinson, J. D.; Thompson, L.
1984-01-01
The feasibility of using a gyroklystron power tube as the final amplifier in a 400 kW CW 34 GHz transmitter on the Goldstone Antenna is investigated. A conceptual design of the gyroklystron and the transmission line connecting it with the antenna feed horn is presented. The performance characteristics of the tube and transmission line are compared to the transmitter requirements for a deep space radar system. Areas of technical risk for a follow-on hardware development program for the gyroklystron amplifier and overmoded transmission line components are discussed.
Cisneros-López, Ma Eugenia; Mendoza-Onofre, Leopoldo E; González-Hernández, Víctor A; Zavaleta-Mancera, H Araceli; Mora-Aguilera, Gustavo; Hernández-Martínez, Miguel; Córdova-Téllez, Leobigildo
2010-04-01
Sorghum ergot (caused by Claviceps africana) is a disease that affects sorghum seed development and yield. The interaction between pollen tube growth and hyphal development determines whether ovaries will be fertilized or colonized. Thus their respective deposition times on the stigma are critical. The effect of the time interval between pollination and inoculation on stigma receptivity and seed production was measured under field conditions in the male-sterile line A9 at Montecillo, State of México (2240m altitude). Pollination and inoculation treatments, from simultaneous application to 2 and 4h difference, were imposed when all stigmas on the panicle had emerged. Control panicles were either only pollinated or only inoculated. Eighteen hours later, pollen grains that adhered to, and germinated within the stigma, pollen tubes in the style and ovary, and fertilized pistils were counted. Pistils showing some disease expression (germinated spores, mycelium growth, or tissue necrosis) at 18, 48, and 72h were recorded. The number of diseased florets was registered at the dough growth stage, while number of seeds, grain yield and 100-seeds weight was measured at the physiological maturity. The pathogen applied in a water suspension of macro and secondary conidia caused a decrease in stigma receptivity; the greatest decrease (40-60%) occurred when the pollen and the inoculum were deposited almost simultaneously, regardless of which was deposited first. The route of the pollen tube was also the route for fungal infection. On average, treatments first inoculated had 60% more diseased florets and 36% less grain yield, 30% fewer seeds and seed size decreased 8%, than those first pollinated. Copyright © 2010 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.
Tube-in-tube thermophotovoltaic generator
Ashcroft, J.; Campbell, B.; DePoy, D.
1998-06-30
A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell. 8 figs.
NASA Astrophysics Data System (ADS)
Zimbardo, G.; Pommois, P.; Veltri, P.
2003-09-01
The influence of magnetic turbulence on magnetic field line diffusion has been known since the early days of space and plasma physics. However, the importance of ``stochastic diffusion'' for energetic particles has been challenged on the basis of the fact that sharp gradients of either energetic particles or ion composition are often observed in the solar wind. Here we show that fast transverse field line and particle diffusion can coexist with small magnetic structures, sharp gradients, and with long lived magnetic flux tubes. We show, by means of a numerical realization of three dimensional magnetic turbulence and by use of the concepts of deterministic chaos and turbulent transport, that turbulent diffusion is different from Gaussian diffusion, and that transport can be inhomogeneous even if turbulence homogeneously fills the heliosphere. Several diagnostics of field line transport and flux tube evolution are shown, and the size of small magnetic structures in the solar wind, like gradient scales and flux tube thickness, are estimated and compared to the observations.
Gagner, Michel; Huang, Rose Y
2016-04-01
Placement of a bougie for sleeve sizing during laparoscopic sleeve gastrectomy (LSG) is recommended. We compared this standard with a suction calibration system (SCS) that performs all functions with one insertion, and measured each step's duration. Primary LSG was performed using a bougie and SCS in alternating order. Number of tube movements to achieve optimal placement, durations of decompression, leak testing, and overall operative time, and remnant linear measurements were obtained. LSG was performed in 26 patients (15 women, 11 men; mean age 36.8 years; mean BMI 45.3 kg/m(2)). The mean number of tube movements was significantly greater for the bougie than for the SCS (8.13 vs. 3.58; p < 0.0001). Percent reductions achieved using the SCS were: time to full decompression of the stomach, 62% (21 vs. 8 s; p < 0.138); tube placement, 51% (101 vs. 49 s; p < 0.0001); leak testing, 78% (119 vs. 26 s; p < 0.0003); and mean operative duration (from tube insertion to end of stapling), 21% (875 vs. 697 s; p < 0.019). Variance of the staple-line distance, measured from the greater curvature to the staple line, was 1.64 and 0.92 for the bougie and SCS, respectively, indicating a reduction in corkscrewing, for a 43.9% straighter sleeve. SCS maintained the gastric wall in place, thereby preventing corkscrewing, and reducing total operating time. Reducing the number of tube insertions may prevent esophageal damage and accidental tube stapling.
Occludin as a functional marker of vascular endothelial cells on tube-forming activity.
Kanayasu-Toyoda, Toshie; Ishii-Watabe, Akiko; Kikuchi, Yutaka; Kitagawa, Hiroko; Suzuki, Hiroko; Tamura, Hiroomi; Tada, Minoru; Suzuki, Takuo; Mizuguchi, Hiroyuki; Yamaguchi, Teruhide
2018-02-01
Cell therapy using endothelial progenitor cells (EPCs) is a promising strategy for the treatment of ischemic diseases. Two types of EPCs have been identified: early EPCs and late EPCs. Late EPCs are able to form tube structure by themselves, and have a high proliferative ability. The functional marker(s) of late EPCs, which relate to their therapeutic potential, have not been fully elucidated. Here we compared the gene expression profiles of several human cord blood derived late EPC lines which exhibit different tube formation activity, and we observed that the expression of occludin (OCLN) in these lines correlated with the tube formation ability, suggesting that OCLN is a candidate functional marker of late EPCs. When OCLN was knocked down by transfecting siRNA, the tube formation on Matrigel, the S phase + G 2 /M phase in the cell cycle, and the spheroid-based sprouting of late EPCs were markedly reduced, suggesting the critical role of OCLN in tube formation, sprouting, and proliferation. These results indicated that OCLN plays a novel role in neovascularization and angiogenesis. © 2017 Wiley Periodicals, Inc.
Failure Analysis of T-38 Aircraft Burst Hydraulic Aileron Return Line
NASA Technical Reports Server (NTRS)
Martinez, J. E.; Figert, J. D.; Paton, R. M.; Nguyen, S. D.; Flint, A.
2012-01-01
During maintenance troubleshooting for fluctuating hydraulic pressures, a technician found that a right hand aileron return line, on the flight hydraulic side, was ruptured (Fig. 1, 2). This tubing is part of the Hydraulic Flight Control Aileron Return Reducer to Aileron Manifold and is suspected to be original to the T-38 Talon trainer aircraft. Ailerons are small hinged sections on the outboard portion of a wing used to generate rolling motion thereby banking the aircraft. The ailerons work by changing the effective shape of the airfoil of the outer portion of the wing [1]. The drawing, Northrop P/N 3-43033-55 (6/1960), specifies that the line is made from 0.375 inch OD, aluminum 5052-0 tubing with a 0.049 inch wall thickness. WW-T-787 requires the tube shall be seamless and uniform in quality and temper [2]. The test pressure for this line is 3000 psi, and the operational pressure for this line is estimated to be between 45 psi and 1500 psi based on dynamic loading during flight. Examination of the fracture surface found evidence of arrest bands originating on the inner diameter (Fig 3). Ductile dimples are observed on the tube fractures (Fig. 4). The etched cross-section revealed thinning and work-hardening in the burst region (Fig. 5). The wall thickness just outside the work-hardened fracture region measured 0.035". Barlow's Formula: P = 2St/D, where P is burst pressure, S is allowable stress, t is wall thickness and D is the outer diameter of tube. Using the ultimate tensile strength of 28 ksi and a measured wall thickness of 0.035 inches at burst, P = 5.2 ksi (burst pressure). Using the yield of 13 ksi (YS) for aluminum 5052-0, plastic deformation will happen at P = 2.4 ksi suggesting plastic deformation occurred at a proof pressure of 3.0 ksi. Conclusion: The burst resulted from high stress, low-cycle fatigue. Evidence of arrest bands originating on the inner diameter. Fracture is predominately shear dimples, characteristic of high load ductile fractures (Fig 6). Section wall reduction in the burst region. Plastic deformation and thinning of the out-of-specification tube wall likely happened during the initial proof testing years ago. Metallography of tubing away from rupture site confirmed tubing was seamless. Based on the tube microstructure, it is likely that the initial wall thickness was about 30 % thinner than the requirement of 0.049 inches. Fracture initiated on the ID and progressed to the OD (shear lip). The tube is made of the correct material of 5052-0 aluminum as verified using Optical Emission Spectroscopy (Table 2). The tubing hardness tested 77 HV100 (77 HRE). This hardness is slightly above the requirement for 70 HRE maximum for aluminum 5052-0 in AMS 2658C [3].
Ultrasonic liquid-in-line detector for tubes
Piper, Thomas C.
1991-01-01
An apparatus and method for detecting the presence of liquid in pipes or tubes using ultrasonic techniques A first piezoelectric crystal is coupled to the outside of the pipe or tube at the location where liquid in the tube is to be detected. A second piezoelectric crystal is coupled to the outside of the pipe or tube at the same location along the tube but circumferentially displaced from the first crystal by an angle around the pipe or tube of less than 180.degree.. Liquid in the pipe or tube is detected by measuring the attenuation of an ultrasonic signal sent by the first piezoelectric crystal and received by the second piezoelectric crystal.
Low heat-leak cryogenic envelope
DeHaan, James R.
1976-10-19
A plurality of cryogenic envelope sections are joined together to form a power transmission line. Each of the sections is comprised of inner and outer tubes having multilayer metalized plastic spirally wrapped within a vacuum chamber formed between the inner and outer tubes. A refrigeration tube traverses the vacuum chamber, but exits one section and enters another through thermal standoffs for reducing heat-leak from the outer tube to the refrigeration tube. The refrigeration tube passes through a spirally wrapped shield within each section's vacuum chamber in a manner so that the refrigeration tube is in close thermal contact with the shield, but is nevertheless slideable with respect thereto.
Wang, L; Chang, S; Guan, J; Shangguan, S; Lu, X; Wang, Z; Wu, L; Zou, J; Zhao, H; Bao, Y; Qiu, Z; Niu, B; Zhang, T
2015-01-01
Epigenetic regulation of long interspersed nucleotide element-1 (LINE-1) retrotransposition events plays crucial roles during early development. Previously we showed that LINE-1 hypomethylation in neuronal tissues is associated with pathogenesis of neural tube defect (NTD). Herein, we further evaluated LINE-1 Homo sapiens (L1Hs) methylation in tissues derived from three germ layers of stillborn NTD fetuses, to define patterns of tissue specific methylation and site-specific hypomethylation at CpG sites within an L1Hs promoter region. Stable, tissue-specific L1Hs methylation patterns throughout three germ layer lineages of the fetus, placenta, and maternal peripheral blood were observed. Samples from maternal peripheral blood exhibited the highest level of L1Hs methylation (64.95%) and that from placenta showed the lowest (26.82%). Between samples from NTDs and controls, decrease in L1Hs methylation was only significant in NTD-affected brain tissue at 7.35%, especially in females (8.98%). L1Hs hypomethylation in NTDs was also associated with a significant increase in expression level of an L1Hs-encoded transcript in females (r = -0.846, p = 0.004). This could be due to genomic DNA instability and alternation in chromatins accessibility resulted from abnormal L1Hs hypomethylation, as showed in this study with HCT-15 cells treated with methylation inhibitor 5-Aza.
Miller, Melissa A; Arndt, Jennifer L; Konkle, Mark A; Chenoweth, Carol E; Iwashyna, Theodore J; Flaherty, Kevin R; Hyzy, Robert C
2011-06-01
The aim of this study was to determine whether the use of a polyurethane-cuffed endotracheal tube would result in a decrease in ventilator-associated pneumonia rate. We replaced conventional endotracheal tube with a polyurethane-cuff endotracheal tube (Microcuff, Kimberly-Clark Corporation, Rosewell, Ga) in all adult mechanically ventilated patients throughout our large academic hospital from July 2007 to June 2008. We retrospectively compared the rates of ventilator-associated pneumonia before, during, and after the intervention year by interrupted time-series analysis. Ventilator-associated pneumonia rates decreased from 5.3 per 1000 ventilator days before the use of the polyurethane-cuffed endotracheal tube to 2.8 per 1000 ventilator days during the intervention year (P = .0138). During the first 3 months after return to conventional tubes, the rate of ventilator-associated pneumonia was 3.5/1000 ventilator days. Use of the polyurethane-cuffed endotracheal tube was associated with an incidence risk ratio of ventilator-associated pneumonia of 0.572 (95% confidence interval, 0.340-0.963). In statistical regression analysis controlling for other possible alterations in the hospital environment, as measured by rate of tracheostomy-ventilator-associated pneumonia, the incidence risk ratio of ventilator-associated pneumonia in patients intubated with polyurethane-cuffed endotracheal tube was 0.565 (P = .032; 95% confidence interval, 0.335-0.953). Use of a polyurethane-cuffed endotracheal tube was associated with a significant decrease in the rate of ventilator-associated pneumonia in our study. Copyright © 2011 Elsevier Inc. All rights reserved.
Chan, Vera B. S.; Thiyagarajan, Vengatesen; Lu, Xing Wen; Zhang, Tong; Shih, Kaimin
2013-01-01
The majority of marine benthic invertebrates protect themselves from predators by producing calcareous tubes or shells that have remarkable mechanical strength. An elevation of CO2 or a decrease in pH in the environment can reduce intracellular pH at the site of calcification and thus interfere with animal’s ability to accrete CaCO3. In nature, decreased pH in combination with stressors associated with climate change may result in the animal producing severely damaged and mechanically weak tubes. This study investigated how the interaction of environmental drivers affects production of calcareous tubes by the serpulid tubeworm, Hydroides elegans. In a factorial manipulative experiment, we analyzed the effects of pH (8.1 and 7.8), salinity (34 and 27‰), and temperature (23°C and 29°C) on the biomineral composition, ultrastructure and mechanical properties of the tubes. At an elevated temperature of 29°C, the tube calcite/aragonite ratio and Mg/Ca ratio were both increased, the Sr/Ca ratio was decreased, and the amorphous CaCO3 content was reduced. Notably, at elevated temperature with decreased pH and reduced salinity, the constructed tubes had a more compact ultrastructure with enhanced hardness and elasticity compared to decreased pH at ambient temperature. Thus, elevated temperature rescued the decreased pH-induced tube impairments. This indicates that tubeworms are likely to thrive in early subtropical summer climate. In the context of climate change, tubeworms could be resilient to the projected near-future decreased pH or salinity as long as surface seawater temperature rise at least by 4°C. PMID:24265732
High-sensitivity interference-free diagnostic for measurement of methane in shock tubes
NASA Astrophysics Data System (ADS)
Sur, Ritobrata; Wang, Shengkai; Sun, Kai; Davidson, David F.; Jeffries, Jay B.; Hanson, Ronald K.
2015-05-01
A sensitive CW laser absorption diagnostic for in-situ measurement of methane mole fraction at high temperatures is developed. The selected transitions for the diagnostic are a cluster of lines near 3148.8 cm-1 from the R-branch of the ν3 band of the CH4 absorption spectrum. The selected transitions have 2-3 times more sensitivity to CH4 concentration than the P-branch in the 3.3 μm region, lower interference from major interfering intermediate species in most hydrocarbon reactions, and applicability over a wide range of pressures and temperatures. Absorption cross-sections for a broad collection of hydrocarbons were simulated to evaluate interference absorption, and were generally found to be negligible near 3148.8 cm-1. However, minor interference from hot bands of C2H2 and C2H4 was observed and was characterized experimentally, revealing a weak dependence on wavelength. To eliminate such interferences, a two-color on-line and off-line measurement scheme is proposed to determine CH4 concentration. The colors selected, i.e., for on-line (3148.81 cm-1) and off-line (3148.66 cm-1), are characterized between 0.2-4 atm and 500 K-2100 K by absorption coefficient measurements in a shock tube. Minimum detectable levels of CH4 in shock tube experiments are reported for this range of temperatures and pressures. An example measurement is shown for sensitive detection of CH4 in a shock tube chemical kinetics experiment.
Improving Paper Machine Efficiency/Productivity through On-line Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cyrus K Aidun
2007-08-31
This project involves implementing a new technology, microforming, in a headbox to produce an isotropic sheet with significant reductions in the MD/CD stiffness ratio (increasing CD specific STFI) and improved sheet uniformity. Microforming involves generating axial vorticity (i.e., swirl) prior to the converging nozzle of the headbox by retrofitting an existing tube block with swirl generation devices referred to as Vortigen system. The Vortigen system developed in this project is a retrofit technology to a hydraulic headbox tube block. The tubes in the tube block are re-designed to generate axial vorticity (or swirl) in the tubes. This type of flowmore » results in higher intensity small-scale turbulence in the forming jet at the slice. The net effect, as demonstrated in pilot and commercial trials, is improvement in formation and surface smoothness, lower MD/CD tensile ratio, and consequently, higher CD strength properties such as CD STFI, Ring Crush and tensile or breaking length. The objective of this project is to implement microforming by developing the retrofit technology for generation and on-line control of axial vorticity in the tubes to optimize turbulent scale and intensity, and consequently, fiber network structure properties in the sheet. This technology results in significant improvements in the performance and capital effectiveness of the paper machine (PM) for a fraction of the cost to replace a headbox. In this project we have developed and demonstrated the concept of generating axial vorticity to control the fiber orientation in the converging zone of the headbox, and to produce a sheet with isotropic fiber orientation. The technology developed here has been demonstrated in static form on several pilot trials and two series of commercial trials. The economic feasibility of this technology is based primarily on fiber savings in cases where a more isotropic fiber orientation can be used to reduce the basis weight of the product. Even a 5% decrease in basis weight will results in substantial savings covering the cost of a commercial retrofit in 6 months or less in a medium size machine. The project also resulted in significant amount of information on fiber orientation in turbulent flow and in a converging nozzle where the results can be used in other applications, such as formation of composite materials. Several MS and Ph.D. students and postdoctoral associates have been trained as part of this project.« less
Effect of the superposition of a dielectric barrier discharge onto a premixed gas burner flame
NASA Astrophysics Data System (ADS)
Zaima, Kazunori; Takada, Noriharu; Sasaki, Koichi
2011-10-01
We are investigating combustion control with the help of nonequilibrium plasma. In this work, we examined the effect of dielectric barrier discharge (DBD) on a premixed burner flame with CH4/O2/Ar gas mixture. The premixed burner flame was covered with a quartz tube. A copper electrode was attached on the outside of the quartz tube, and it was connected to a high-voltage power supply. DBD inside the quartz tube was obtained between the copper electrode and the grounded nozzle of the burner which was placed at the bottom of the quartz tube. We clearly observed that the flame length was shortened by superposing DBD onto the bottom part of the flame. The shortened flame length indicates the enhancement of the burning velocity. We measured the optical emission spectra from the bottom region of the flame. As a result, we observed clear line emissions from Ar, which were never observed from the flame without DBD. We evaluated the rotational temperatures of OH and CH radicals by spectral fitting. As a result, the rotational temperature of CH was not changed, and the rotational temperature of OH was decreased by the superposition of DBD. According to these results, it is considered that the enhancement of the burning velocity is not caused by gas heating. New reaction pathways are suggested.
Wang, Shigang; Rosenthal, Tami; Kunselman, Allen R; Ündar, Akif
2015-01-01
The objective of this study is to evaluate three different diameters of arterial tubing and three diameters of arterial cannulae in terms of pressure drop, and hemodynamic energy delivery in simulated neonatal/pediatric cardiopulmonary bypass (CPB) circuits. The CPB circuit consisted of a Terumo Capiox Baby FX05 oxygenator (Terumo Corporation, Tokyo, Japan), arterial tubing (1/4 in, 3/16 in, or 1/8 in × 150 cm), and a Medtronic Bio-Medicus arterial cannula (8, 10, or 12 Fr; Medtronic, Inc., Minneapolis, MN, USA). The pseudo patient's pressure was maintained at 50 mm Hg. The circuit was primed using lactated Ringer's solution and heparinized packed human red blood cells (hematocrit 30%). Trials were conducted at different flow rates and temperatures (35 and 28°C). Flow and pressure data were collected using a custom-based data acquisition system. Using 8 Fr arterial cannula at 500 mL/min, small diameter arterial tubing generated higher circuit pressure (294.6 ± 0.1 mm Hg [1/8 in], 213.5 ± 0.5 mm Hg [3/16 in], 208.4 ± 0.4 mm Hg [1/4 in] at 35°C) and arterial line pressure drop (158.3 ± 0.1 mm Hg [1/8 in], 79.6 ± 0.1 mm Hg [3/16 in], 62.1 ± 0.1 mm Hg [1/4 in] at 35°C). Using 10 Fr arterial cannula at 1000 mL/min, pre-oxygenator pressures were 266.8 ± 0.2 mm Hg (3/16 in) and 248.0 ± 0.3 mm Hg (1/4 in); arterial line pressure drops were 111.6 ± 0.0 mm Hg (3/16 in) and 74.0 ± 0.1 mm Hg (1/4 in) at 35°C. When using 12 Fr arterial cannula at 1500 mL/min, preoxygenator pressures reached 324.4 ± 0.3 mm Hg (3/16 in) and 302.5 ± 0.4 mm Hg (1/4 in); arterial line pressure drops were 154.0 ± 0.1 mm Hg (3/16 in) and 92.0 ± 0.2 mm Hg (1/4 in) at 35°C. Pressure drops across arterial line tubing were main CPB circuit pressure drops. High flow rate, hypothermia, small diameter arterial tubing. and arterial cannula created more hemodynamic energy at the preoxygenator site, but energy loss across CPB circuit also increased. Although small diameter (<1/4 in ID) arterial tubing may decrease total CPB priming volume, it also led to significantly higher circuit pressure, higher pressure drop, and more hemodynamic energy loss across CPB circuit. Larger diameter arterial cannula had less pressure drop and allowed more hemodynamic energy delivery to the patient. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Self-monitoring high voltage transmission line suspension insulator
Stemler, Gary E.; Scott, Donald N.
1981-01-01
A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John
2007-07-15
The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary studymore » on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM in neonates and young children was found to be lower than that obtained for adults. Therefore, on-line TCM should work as an additional means to reduce dose and should not replace other conventional means of reducing dose, especially in neonates and young children.« less
Jensen, A.S.; Gray, G.W.
1958-07-01
Beam deflection tubes are described for use in switching or pulse amplitude analysis. The salient features of the invention reside in the target arrangement whereby outputs are obtained from a plurality of collector electrodes each correspondlng with a non-overlapping range of amplitudes of the input sigmal. The tube is provded with mcans for deflecting the electron beam a1ong a line in accordance with the amplitude of an input signal. The target structure consists of a first dymode positioned in the path of the beam wlth slots spaced a1ong thc deflection line, and a second dymode posltioned behind the first dainode. When the beam strikes the solid portions along the length of the first dymode the excited electrons are multiplied and collected in separate collector electrodes spaced along the beam line. Similarly, the electrons excited when the beam strikes the second dynode are multiplied and collected in separate electrodes spaced along the length of the second dyode.
CALANDRIA TYPE SODIUM GRAPHITE REACTOR
Peterson, R.M.; Mahlmeister, J.E.; Vaughn, N.E.; Sanders, W.J.; Williams, A.C.
1964-02-11
A sodium graphite power reactor in which the unclad graphite moderator and fuel elements are contained within a core tank is described. The core tank is submersed in sodium within the reactor vessel. Extending longitudinally through the core thnk are process tubes with fuel elements positioned therein. A bellows sealing means allows axial expansion and construction of the tubes. Within the core tank, a leakage plenum is located below the graphite, and above the graphite is a gas space. A vent line regulates the gas pressure in the space, and another line removes sodium from the plenum. The sodium coolant flows from the lower reactor vessel through the annular space between the fuel elements and process tubes and out into the reactor vessel space above the core tank. From there, the heated coolant is drawn off through an outlet line and sent to the heat exchange. (AEC)
The utilization of intravenous therapy programs in community long-term care nursing facilities.
Weinberg, A D; Pals, J K; Wei, J Y
1997-01-01
To determine if non-federal Boston-area long-term care nursing facilities are actively using intravenous (IV) therapy as a form of treatment, the specific design of such programs and to assess the availability of central line IVs, percutaneous endoscopic gastrostomy (PEG) tubes and hypodermoclysis for hydration in this setting. DESIGN/SETTINGS: A prospective telephone survey of 100 Boston-area skilled nursing facilities, each with a minimum of 50 beds and representing a total of 12,763 beds, certified to provide both Medicaid (Title-19) and Medicare services, to ascertain their ability to provide IV and other modes of hydration for their residents. A series of questions were asked of a member of the staff knowledgeable in the operations of the nursing facility. Questions included whether an IV program was in existence, duration of the program, provider of IV training for nurses, presence of a subacute unit, whether IVs were administered in non-subacute areas, frequency of IV usage, the ability to manage central lines and the use of PEG tubes or hypodermoclysis for hydration. A total of 100 nursing facilities were surveyed between September and October of 1996. A total of 79 nursing facilities had active IV programs (79%) and 54 of those (68%) also managed central lines. However, in those facilities with active IV programs, 73% (N = 58) reported administering a total of less than five IVs per month. Training for 82% of the nursing facilities (N = 65) was by an outside vendor pharmacy and initial training ranged from one to three days in duration. Of the 19 nursing facilities with IV programs available only in subacute or equivalent units, only 26% (N = 5) did not allow direct transfer of residents from other wards into these units. Of the 79 nursing facilities having IV capability, a total of 91% (N = 72) have also used PEG tubes for hydration and nutritional needs although only 6% (N = 5) have ever used hypodermoclysis for hydration. The majority of nursing facilities in the Boston area provide IV programs for their residents, although in limited numbers on a monthly basis. Residents with central lines are admitted in the majority of these nursing facilities although total staff training time is only one to three days. The use of PEG tubes for hydration is quite frequent, although the use of hypodermoclysis was extremely low. Further work is necessary to fully elucidate the clinical implications of whether these programs decrease the need for acute hospitalization or are used mainly in the post-hospitalization (Medicare A-covered) period.
You have two kidneys. They are fist-sized organs on either side of your backbone above your waist. The tubes inside filter and ... blood, taking out waste products and making urine. Kidney cancer forms in the lining of tiny tubes ...
Effect of flow rate and insulin priming on the recovery of insulin from microbore infusion tubing.
Fuloria, M; Friedberg, M A; DuRant, R H; Aschner, J L
1998-12-01
A retrospective medical record review of 13 consecutive, hyperglycemic, extremely low birth weight (ELBW) infants treated with continuous insulin infusions revealed a 14- to 24-hour delay (mean, 19 hours) in blood glucose normalization despite stepwise increases in insulin infusion rates. This in vitro study examined the effects of flow rate and insulin priming on insulin recovery from polyvinyl chloride (PVC) tubing and polyethylene (PE)-lined PVC tubing infused with a standard insulin stock solution. Stock insulin solution (0.2 U/mL) was infused through microbore PVC or PE-lined tubing at flow rates of 0.05 and 0.2 mL/h. To determine if saturation of nonspecific binding sites would alter effluent insulin concentration, we compared insulin recovery from tubing previously flushed with the stock solution and tubing primed with 5 U/mL of insulin for 20 minutes. Effluent samples, which were collected at baseline and at six time points during a 24-hour period, were immediately frozen at -20 degreesC. Insulin concentration was measured by IMx immunoassay. Data were analyzed using general linear modeling with repeated measures. At 0.05 mL/h flow rate, insulin recovery from unprimed PVC tubing at 1, 2, 4, and 8 hours was 17%, 11%, 27%, and 55%, respectively, with 100% recovery at 24 hours. From insulin-primed tubing, insulin recovery was approximately 70% at 1, 2, and 4 hours, and close to 100% at 8 hours. At a faster flow rate of 0.2 mL/h, insulin recovery at 1, 2, 4, and 8 hours was 22%, 38%, 67%, and 75% vs 42%, 85%, 91% and 95% from unprimed and insulin-primed PVC tubing, respectively. Similar results were obtained from unprimed and insulin-primed PE-lined tubing at 0.2 mL/h flow rate. Priming of microbore tubing with 5 U/mL of insulin solution for 20 minutes to block nonspecific binding sites enhances delivery of a standard insulin stock at infusion rates typically used to treat hyperglycemic ELBW infants. We conclude that priming the tubing with a higher concentration of insulin before initiation of standard insulin infusion therapy should accelerate achievement of steady-state insulin delivery and correction of hyperglycemia in ELBW infants.
K2-EDTA and K3-EDTA Greiner Tubes for HbA1c Measurement.
Vrtaric, Alen; Filipi, Petra; Hemar, Marina; Nikolac, Nora; Simundic, Ana-Maria
2016-02-01
To determine whether K2-ethylenediaminetetraacetic acid (EDTA) and K3-EDTA Greiner tubes could be used interchangeably for glycosylated hemoglobin, type A1C (HbA1c) measurement via the Abbott Laboratories ARCHITECT chemiluminescent microparticle HbA1c assay on the ARCHITECT i2000SR immunoanalyzer at our university hospital. We drew blood from a total of 45 outpatients into plastic Greiner Vacuette tubes, some of which were lined with K2-EDTA and others with K3-EDTA anticoagulant. Data are presented as median and interquartile range values. We used the Wilcoxon test and Passing-Bablok regression for tube comparison. For K2-EDTA tubes median HbA1c concentration was 54 mmol/mol (41 to 71 mmol/mol) and for K3-EDTA tubes 56 mmol/mol (43 to 69 mmol/mol). There was no statistically significant difference between K2-EDTA and K3-EDTA (bias= -1.29 mmol/mol; P = 0.24). Passing-Bablok regression showed that there is no constant and proportional error: y = -0.23 (95% CI[-3.52 to 0.69]) + 1.00( 95% CI[0.98 to 1.06]) x. In this study, we provide evidence for the lack of any clinically and statistically significant bias between K2-EDTA and K3-EDTA HbA1c measurements. Thus, Greiner tubes lined with K2-EDTA and those lined with K3-EDTA can safely be used interchangeably to measure HbA1c via the Abbott Laboratories ARCHITECT assay. © American Society for Clinical Pathology, 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Hirsch, Helmut V. B.; Possidente, Debra; Averill, Sarah; Despain, Tamira Palmetto; Buytkins, Joel; Thomas, Valerie; Goebel, W. Paul; Shipp-Hilts, Asante; Wilson, Diane; Hollocher, Kurt; Possidente, Bernard; Lnenicka, Greg; Ruden, Douglas M.
2009-01-01
We developed Drosophila melanogaster as a model to study correlated behavioral, neuronal and genetic effects of the neurotoxin lead, known to affect cognitive and behavioral development in children. We showed that, as in vertebrates, lead affects both synaptic development and complex behaviors (courtship, fecundity, locomotor activity) in Drosophila. By assessing differential behavioral responses to developmental lead exposure among recombinant inbred Drosophila lines (RI), derived from parental lines Oregon R and Russian 2b, we have now identified a genotype by environment interaction (GEI) for a behavioral trait affected by lead. Drosophila Activity Monitors (TriKinetics, Waltham, MA), which measure activity by counting the number of times a single fly in a small glass tube walks through an infrared beam aimed at the middle of the tube, were used to measure activity of flies, reared from eggs to 4 days of adult age on either control or lead-contaminated medium, from each of 75 RI lines. We observed a significant statistical association between the effect of lead on average daytime activity across lines and one marker locus, 30AB, on chromosome 2; we define this as a Quantitative Trait Locus (QTL) associated with behavioral effects of developmental lead exposure. When 30AB was from Russian 2b, lead significantly increased locomotor activity, whereas, when 30AB was from Oregon R, lead decreased it. 30AB contains about 125 genes among which are likely “candidate genes” for the observed lead-dependent behavioral changes. Drosophila are thus a useful, underutilized model for studying behavioral, synaptic and genetic changes following chronic exposure to lead or other neurotoxins during development. PMID:19428504
NASA Astrophysics Data System (ADS)
Hu, Yuanyuan; Xu, Yingying; Hao, Qun; Hu, Yao
2013-12-01
The tubing internal thread plays an irreplaceable role in the petroleum equipment. The unqualified tubing can directly lead to leakage, slippage and bring huge losses for oil industry. For the purpose of improving efficiency and precision of tubing internal thread detection, we develop a new non-contact tubing internal thread measurement system based on the laser triangulation principle. Firstly, considering that the tubing thread had a small diameter and relatively smooth surface, we built a set of optical system with a line structured light to irradiate the internal thread surface and obtain an image which contains the internal thread profile information through photoelectric sensor. Secondly, image processing techniques were used to do the edge detection of the internal thread from the obtained image. One key method was the sub-pixel technique which greatly improved the detection accuracy under the same hardware conditions. Finally, we restored the real internal thread contour information on the basis of laser triangulation method and calculated tubing thread parameters such as the pitch, taper and tooth type angle. In this system, the profile of several thread teeth can be obtained at the same time. Compared with other existing scanning methods using point light and stepper motor, this system greatly improves the detection efficiency. Experiment results indicate that this system can achieve the high precision and non-contact measurement of the tubing internal thread.
Ultrasonic thickness measuring and imaging system and method
Bylenok, Paul J.; Patmos, William M.; Wagner, Thomas A.; Martin, Francis H.
1992-08-04
An ultrasonic thickness measuring and imaging system uses an ultrasonic fsed beam probe for measuring thickness of an object, such as a wall of a tube, a computer for controlling movement of the probe in a scanning pattern within the tube and processing an analog signal produced by the probe which is proportional to the tube wall thickness in the scanning pattern, and a line scan recorder for producing a record of the tube wall thicknesses measured by the probe in the scanning pattern. The probe is moved in the scanning pattern to sequentially scan circumferentially the interior tube wall at spaced apart adjacent axial locations. The computer processes the analog signal by converting it to a digital signal and then quantifies the digital signal into a multiplicity of thickness points with each falling in one of a plurality of thickness ranges corresponding to one of a plurality of shades of grey. From the multiplicity of quantified thickness points, a line scan recorder connected to the computer generates a pictorial map of tube wall thicknesses with each quantified thickness point thus being obtained from a minute area, e.g. 0.010 inch by 0.010 inch, of tube wall and representing one pixel of the pictorial map. In the pictorial map of tube wall thicknesses, the pixels represent different wall thicknesses having different shades of grey.
Ultrasonic thickness measuring and imaging system and method
Bylenok, Paul J.; Patmos, William M.; Wagner, Thomas A.; Martin, Francis H.
1992-01-01
An ultrasonic thickness measuring and imaging system uses an ultrasonic fsed beam probe for measuring thickness of an object, such as a wall of a tube, a computer for controlling movement of the probe in a scanning pattern within the tube and processing an analog signal produced by the probe which is proportional to the tube wall thickness in the scanning pattern, and a line scan recorder for producing a record of the tube wall thicknesses measured by the probe in the scanning pattern. The probe is moved in the scanning pattern to sequentially scan circumferentially the interior tube wall at spaced apart adjacent axial locations. The computer processes the analog signal by converting it to a digital signal and then quantifies the digital signal into a multiplicity of thickness points with each falling in one of a plurality of thickness ranges corresponding to one of a plurality of shades of grey. From the multiplicity of quantified thickness points, a line scan recorder connected to the computer generates a pictorial map of tube wall thicknesses with each quantified thickness point thus being obtained from a minute area, e.g. 0.010 inch by 0.010 inch, of tube wall and representing one pixel of the pictorial map. In the pictorial map of tube wall thicknesses, the pixels represent different wall thicknesses having different shades of grey.
Choice-reaction time to visual motion with varied levels of simultaneous rotary motion
NASA Technical Reports Server (NTRS)
Clark, B.; Stewart, J. D.
1974-01-01
Twelve airline pilots were studied to determine the effects of whole-body rotation on choice-reaction time to the horizontal motion of a line on a cathode-ray tube. On each trial, one of five levels of visual acceleration and five corresponding proportions of rotary acceleration were presented simultaneously. Reaction time to the visual motion decreased with increasing levels of visual motion and increased with increasing proportions of rotary acceleration. The results conflict with general theories of facilitation during double stimulation but are consistent with neural-clock model of sensory interaction in choice-reaction time.
Korczyński, P; Górska, K; Nasiłowski, J; Chazan, R; Krenke, R
2015-01-01
Beside standard chest tube drainage other less invasive techniques have been used in the management of patients with an acute episode of spontaneous pneumothorax. The aim of the study was to evaluate the short term effect of spontaneous pneumothorax treatment with small-bore pleural catheter and manual aspiration as compared to large-bore chest tube drainage. Patients with an episode of pneumothorax who required pleural intervention were enrolled in the study and randomly assigned to one of the treatment arms: (1) small-bore pleural catheter (8 Fr) with manual aspiration; (2) standard chest tube drainage (20-24 Fr). Success rate of the first line treatment, duration of catheter or chest tube drainage, and the need for surgical intervention were the outcome measures. The study group included 49 patients (mean age 46.9±21.3 years); with 22 and 27 allocated to small bore manual aspiration and chest tube drainage groups, respectively. There were no significant differences in the baseline characteristics of patients in both therapeutic arms. First line treatment success rates were 64% and 82% in the manual aspiration and chest tube drainage groups, respectively; the difference was insignificant. Median time of treatment with small bore catheter was significantly shorter than conventional chest tube drainage (2.0 vs. 6.0 days; p<0.05). Our results show that treatment of spontaneous pneumothorax with small-bore pleural catheter and manual aspiration might be similarly effective as is chest tube drainage in terms of immediate lung re-expansion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Qin; Zhao, Qing
Grain boundary engineering (GBE) of nickel-based alloy 825 tubes was carried out with different cold drawing deformations by using a draw-bench on a factory production line and subsequent annealing at various temperatures. The microstructure evolution of alloy 825 during thermal-mechanical processing (TMP) was characterized by means of the electron backscatter diffraction (EBSD) technique to study the TMP effects on the grain boundary network and the evolution of grain boundary character distributions during high temperature annealing. The results showed that the proportion of ∑ 3{sup n} coincidence site lattice (CSL) boundaries of alloy 825 tubes could be increased to > 75%more » by the TMP of 5% cold drawing and subsequent annealing at 1050 °C for 10 min. The microstructures of the partially recrystallized samples and the fully recrystallized samples suggested that the proportion of low ∑ CSL grain boundaries depended on the annealing time. The frequency of low ∑ CSL grain boundaries increases rapidly with increasing annealing time associating with the formation of large-size highly-twinned grains-cluster microstructure during recrystallization. However, upon further increasing annealing time, the frequency of low ∑ CSL grain boundaries decreased markedly during grain growth. So it is concluded that grain boundary engineering is achieved through recrystallization rather than grain growth. - Highlights: •The grain boundary engineering (GBE) is applicable to 825 tubes. •GBE is achieved through recrystallization rather than grain growth. •The low ∑ CSL grain boundaries in 825 tubes can be increased to > 75%.« less
NEUTRONIC REACTOR FUEL ELEMENT
Horning, W.A.; Lanning, D.D.; Donahue, D.J.
1959-10-01
A fuel slug for a reactor which acts as a safety device is described. The fuel slug is an aluminum tube with a foil lining the inside surface of the tube, the foil being fabricated of uranium in a lead matrix.
Study on a 10 W/90 K in-line pulse tube cryocooler
NASA Astrophysics Data System (ADS)
Zhang, Ankuo; Chen, Xi; Wu, Yi Nong; Zhang, Hua; Yang, Kaixiang
2012-12-01
A Stirling-type in-line pulse tube cryocooler (PTC) has been designed, built and tested at Shanghai Institute of Technical Physics (SITP), Chinese Academy of Sciences. This PTC prototype can obtain a low-noise cooling capacity of more than 10 W at around 90 K cold head temperature and is used for cooling a space-borne infrared photo detector. In order to achieve a highly efficient PTC, a simplified numerical simulation model has been established for design and optimization. The simulation results of the regenerator, pulse tube and inertance tube are analyzed in detail. Besides, some key parameters of the PTC are listed in the paper. The PTC's performances are tested at different operating frequencies from 42 Hz to 55 Hz and its reject temperature dependence is observed in the range of 290 K to 320 K. Furthermore, the map of the PTC's performance characteristics is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siegmund, O. H. W.; McPhate, J. B.; Tremsin, A. S.
Novel microchannel plates have been constructed using borosilicate glass micro-capillary array substrates with 20 mu m and 10 mu m pores and coated with resistive, and secondary electron emissive, layers by atomic layer deposition. Microchannel plates in 33 mm, 50 mm and 20 cm square formats have been made and tested. Although their amplification, imaging, and timing properties are comparable to standard glass microchannel plates, the background rates and lifetime characteristics are considerably improved. Sealed tube detectors based on the Planacon tube, and a 25 mm cross delay line readout tube with a GaN(Mg) opaque photocathode deposited on borosilicate microchannelmore » plates have been fabricated. Considerable progress has also been made with 20 cm microchannel plates for a 20 cm format sealed tube sensor with strip-line readout that is being developed for Cherenkov light detection.« less
Goldberg, D.A.; Flood, W.S.; Arthur, A.A.; Voelker, F.
1984-03-20
A broad-band beam bunther is disclosed, comprising an evacuated housing, an electron gun therein for producing an electron beam, a buncher cavity having entrance and exit openings through which the beam is directed, grids across such openings, a source providing a positive DC voltage between the cavity and the electron gun, a drift tube through which the electron beam travels in passing through such cavity, grids across the ends of such drift tube, gaps being provided between the drift tube grids and the entrance and exit grids, a modulator for supplying an ultrahigh frequency modulating signal to the drift tube for producing velocity modulation of the electrons in the beam, a drift space in the housing through which the velocity modulated electron beam travels and in which the beam is bunched, and a discharge opening from such drift tube and having a grid across such opening through which the bunched electron beam is discharged into an accelerator or the like. The buncher cavity and the drift tube may be arranged to constitute an extension of a coaxial transmission line which is employed to deliver the modulating signal from a signal source. The extended transmission line may be terminated in its characteristic impedance to afford a broad-
Free-surface entrainment into a rimming flow containing surfactants
NASA Astrophysics Data System (ADS)
Thoroddsen, S. T.; Tan, Y.-K.
2004-02-01
We study experimentally the free-surface entrainment of tubes into a steady rimming flow formed inside a partially filled horizontally rotating cylinder. The liquid consists of a glycerin-water mixture containing surfactants (fatty acids). The phenomenon does not occur without the surfactants and the details are sensitive to their concentration. The entrainment of numerous closely spaced air tubes and/or surfactant columns can start intermittently along a two-dimensional stagnation line, but is usually associated with the appearance of an axially periodic vortex structure, the so-called shark teeth, which fixes the spanwise location of these tubes. The number of tubes is governed by the three-dimensional shape of the free surface, reducing from more than 10 to only two in each trough, as the rotation rate is increased. The tubes vary in diameter from 10-30 μm and can extend hundreds of diameters into the liquid layer before breaking up into a continuous stream of bubbles and/or drops. The tubes are driven through the stagnation line by the strong viscous shear and are stretched in the downstream direction. The entrainment starts when the Capillary number Ca=μωR/σ≃0.4.
Collecting maple sap with unvented spouts, using aerial and ground lines
H. Clay Smith; Carter B. Gibbs
1971-01-01
Two methods of using plastic tubing to collect sugar maple sap were tried: aerial lines and ground lines. Unvented spouts were used in both. We found that the sap yields collected from the aerial and ground lines were not statistically different from each other.
NASA Technical Reports Server (NTRS)
Weilmuenster, K. J.
1974-01-01
Experimental measurements of boundary-layer transition in an expansion-tube test-gas flow are presented along with radial distributions of pitot pressure. An integral method for calculating constant Reynolds number lines for an expansion-tube flow is introduced. Comparison of experimental data and constant Reynolds number calculations has shown that for given conditions, wall boundary-layer transition occurs at a constant Reynolds number in an expansion-tube flow. Operating conditions in the expansion tube were chosen so that the effects of test-gas nonequilibrium on boundary-layer transition could be studied.
Evidence for siphon flows with shocks in solar magnetic flux tubes
NASA Technical Reports Server (NTRS)
Degenhardt, D.; Solanki, S. K.; Montesinos, B.; Thomas, J. H.
1993-01-01
We synthesize profiles of the infrared line Fe I 15648.5 A (g = 3) for a recently developed theoretical model of siphon flows along photospheric magnetic loops. The synthesized line profiles are compared with the observations from which Rueedi et al. (1992) deduced the presence of such flows across the neutral line of an active region plage. This comparison supports the interpretation of Rueedi et al. (1992). It also suggests that the average footpoint separation of the observed loops carrying the siphon flow is 8-15 sec and that the siphon flow experiences a standing tube shock in the downstream leg near the top of the arch.
Tubbs, Kyle J; Silva, Rodrigo C; Ramirez, Harvey E; Castleman, William L; Collins, William O
2013-01-01
Balloon dilation is accepted as a first line treatment of acute subglottic stenosis, but its effects on the subglottic tissue remain largely unknown. We aimed to develop an animal model of acute subglottic stenosis using endoscopic techniques. Once developed, this model was used to compare the immediate effects of balloon dilation and endotracheal tube dilation on subglottic tissue. Prospective randomized animal study. Acute subglottic injury was induced in 10 ferrets by endoscopic cauterization with silver nitrate. After 48-72 hours of observation, eight animals were randomized to undergo subglottic dilation with either a 5-mm balloon or endotracheal tubes of increasing diameter. These eight ferrets were euthanized within 10 minutes after dilation. The other two ferrets served as controls and were euthanized following observation only. The larynx from each ferret was harvested, and the subglottis was examined histologically by a pathologist blinded to the treatment arms. Acute subglottic stenosis was induced in all 10 ferrets using the endoscopic technique. Both balloon and endotracheal tube dilation resulted in comparable improvement in the subglottic airway diameter. A decreased thickness of submucosa/lamina propria was seen in the balloon dilation group. Acute subglottic stenosis can be reliably induced in ferrets using endoscopic techniques. Multiple dilation methods can be used to relieve acute obstruction. Balloon dilators seem to improve airway patency, in part, by decreasing the thickness of the submucosa and lamina propria. Further research is needed to determine how this impacts later stages of wound healing and final outcomes. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Liu, Xijing; Chen, Hongqin; Kong, Weiqi; Zhang, Yanping; Cao, Liyuan; Gao, Linbo; Zhou, Rong
2017-01-01
Preeclampsia is a pregnancy-specific syndrome and is one of the main causes of maternal, fetal, and neonatal morbidity and mortality. Inadequate trophoblast invasion and failure of uterine spiral artery remodeling exert a major role in the development of preeclampsia, especially the early-onset one. LncRNA-ATB is verified to be aberrantly expressed in many cancers and promote the invasion-metastasis and proliferation cascades. But little is known of lncRNA-ATB's role in preeclampsia. The aim of current study is to identify the changes of lncRNA-ATB in preeclampsia and its effects on trophoblast. The lncRNA-ATB levels were decreased in placental samples collected from preeclampsia women (n = 51) compared to those of healthy pregnant women (n = 40) by qRT-PCR analysis. Besides, it is demonstrated that lncRNA-ATB was intense stained in the trophoblast of the placenta by performing in-situ hybridization. By designing RNA interference species to suppress lncRNA-ATB and specific plasmids designed to overexpress lncRNA-ATB, we identify the role of lncRNA-ATB on the functions of trophoblast cell-line, HTR-8/SVneo. Inhibition of endogenous lncRNA-ATB decreased migration, proliferation, tube-formation of HTR-8/SVneo cells. In addition, overexpression of lncRNA-ATB promoted migration, proliferation, and tube-formation of HTR-8/SVneo cells. Therefore, lncRNA-ATB might be involved in the pathogenesis of preeclampsia by regulating the process of trophoblast invasion and endovascular formation. Copyright © 2016 Elsevier Ltd. All rights reserved.
HEAVY WATER MODERATED NEUTRONIC REACTOR
Szilard, L.
1958-04-29
A nuclear reactor of the type which utilizes uranium fuel elements and a liquid coolant is described. The fuel elements are in the form of elongated tubes and are disposed within outer tubes extending through a tank containing heavy water, which acts as a moderator. The ends of the fuel tubes are connected by inlet and discharge headers, and liquid bismuth is circulated between the headers and through the fuel tubes for cooling. Helium is circulated through the annular space between the outer tubes in the tank and the fuel tubes to cool the water moderator to prevent boiling. The fuel tubes are covered with a steel lining, and suitable control means, heat exchange means, and pumping means for the coolants are provided to complete the reactor assembly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Facteau, T.J.; Wang, S.Y.; Rowe, K.E.
1973-05-01
Increased fluoride (F) fumigation levels resulted in decrease in percent Royal Ann pollen germination and pollen tube growth. As dose (hour x concentration in ..mu.. gF/m/sup 3/) increased, Van pollen tube growth in vivo decreased. A linear relationship between increased dose and fluoride residue in the flowers was shown. 14 references, 5 figures.
Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendler, O J; Takeuchi, K; Young, M Y
1986-10-01
The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results.
Oxytropism: a new twist in pollen tube orientation
NASA Technical Reports Server (NTRS)
Blasiak, J.; Mulcahy, D. L.; Musgrave, M.
2001-01-01
Chemical gradients and structural features within the pistil have been previously proposed as factors determining the directionality of pollen tube growth. In this study, we examine the behavior of pollen of eight species germinated in a dynamic oxygen gradient. While the germination rates of some species decreased directly with decreasing oxygen tension, other species showed no decrease in germination at oxygen tensions as low as 2 kPa. In one species, germination was consistently greater at decreased oxygen tensions than at ambient atmospheric levels. In three of the eight species tested, the developing pollen tube showed clear directional growth away from the more-oxygenated regions of the growth medium, while in one species growth was towards the more-oxygenated region. The remaining four species showed random tube growth. The pattern of oxytropic responses among the taxa suggests that this tropic behavior is both widespread and phylogenetically unpredictable.
Ceramic tube seals cut heat loss, achieve six month payback
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-11-01
The methane reformer at the Celanese Chemical Company's Bishop, TX plant operates at approximately 1900/sup 0/F. The reformer has 32 tubes (9'' diameter) that pass through the firebox. Openings around the tubes measure 11'' in diameter to accommodate horizontal and vertical thermal expansion and movement as well as to facilitate tube removal. The gaps around the tubes permitted cool air to be drawn into the firebox (caused by slight negative pressure) and also allowed radiant heat to escape causing the reformer to operate at a lower than desired level of thermal efficiency. Celanese contracted to retrofit the old rigid firebrickmore » roof in the methane reformer with a 10'' thick ceramic fiber module lining. The gaps around the tubes were sealed by using a special tube seal made from Nextel woven ceramic fiber fabric, a 1984 CHEMICAL PROCESSING Vaaler Award winner (Mid-November 1984, p.52). The Nextel fabric used in this application is a heat resistant textile that has a continuous use temperature of 2200/sup 0/F - well above the 1900/sup 0/F operating temperature of the reformer. The tube seals have been working exactly as intended, verified by observation through inspection ports. Temperatures in the penthouse area above the roof dropped from 240/sup 0/F to 150/sup 0/F. The reduction in heat losses has been attributed to the elimination of the gaps around each tube by the seals and to the improved K-factor of the ceramic module lining. The tube seals have paid for themselves within six months of installation. At that time, the seal boots were inspected and showed no signs of wear. With these results, the improved efficiency of the methane reformer promises to yield additional economic benefits.« less
Lagacé, L; Jacques, M; Mafu, A A; Roy, D
2006-05-25
The bacterial microflora of maple sap and biofilms in collection system tubing were studied through the use of bacterial counts, scanning electron microscopy (SEM) of surfaces and the analysis of 16S rRNA gene by denaturing gradient gel electrophoresis (DGGE). Samples were taken at five times during the 2002 and 2003 seasons in order to follow the changes in the microflora of this complex ecosystem. Bacterial counts showed the growth of bacterial populations as the season advanced. These populations were mainly composed of psychrotrophic bacteria and Pseudomonas spp. SEM results confirmed the suspected presence of biofilms on the inner surfaces of tubing samples. Bacterial colonization and biofilm formation progressively increased during the season for both lateral and main line surfaces, and biofilms were mainly composed of rod shape bacteria. The bacterial microflora profiles obtained for sap and corresponding biofilm by DGGE showed up to 12 major bands. The Shannon-Weaver index of diversity (H) calculated from DGGE bands were statistically higher for sap samples compared to biofilm. The diversity index was relatively stable or increasing for lateral line sap and biofilm samples during the season while the diversity index for sap and biofilm samples of the main line showed a decreasing profile as the season progressed. Sequence analysis of major DGGE bands revealed the predominance of bacteria from the genera Pseudomonas, Rahnella and another, unidentified genus. The results describe the composition of sap collection system microflora as well as the formation of biofilms and will be useful for further studies on factors affecting maple product quality.
Dengler, V; Wilde, P; Byhahn, C; Mack, M G; Schalk, R
2011-02-01
Laryngeal tubes (LT) are increasingly being used for emergency airway management. This article reports on two patients in whom out-of-hospital intubation with a single-lumen LT was associated with massive pulmonary aspiration in one patient and gastric overinflation in the other. In both cases peak inspiratory pressures exceeded the LT leak pressure of approximately 35 mbar. This resulted in gastric inflation and decreased pulmonary compliance and increased inspiratory pressure further, thereby creating a vicious circle. It is therefore recommended that laryngeal tube suction (LTS) should be used in all cases of emergency airway management and a gastric drain tube be inserted through the dedicated second lumen. Apart from gastric overinflation, incorrect LT/LTS placement must be detected and immediately corrected, e.g. in cases of difficult or impossible gastric tube placement, permanent drainage of air from the gastric tube, decreasing minute ventilation or an ascending capnography curve.
NASA Astrophysics Data System (ADS)
Wang, Xinyi; Shen, Jialong; Liu, Xinbo
2018-01-01
Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.
Experimental and analytical studies in fluids
NASA Technical Reports Server (NTRS)
Goglia, Gene L.; Ibrahim, Adel
1984-01-01
The first objective was to analyze and design a true airspeed sensor which will replace the conventional pitot-static pressure transducer for small commercial aircraft. The second objective was to obtain a numerical solution and predict the frequency response which is generated by the vortex whistle at a certain airspeed. It was concluded flow rate measurements indicate that the vortex tube sound frequency is linearly proportional to the frequency response. The vortex tube whistle frequency is dependent upon geometrical parameters to such an extent that: an increase in vortex tube length produces a decrease in frequency response and that an increase in the exhaust nozzle length produces an increase in the frequency precession. An increase in the vortex tube diameter produces a decrease in frequency precession. An increase in swirler diameter produces a decrease in frequency. An increase in the location distance of the microphone pickup signal point from the inside edge of the exit nozzle produces an increase in frequency response. The experimental results indicate that those parameters most significantly effecting frequency are in descending order of importance microphone location, vortex tube diameter, exit nozzle length, vortex tube length, and swirler diameter.
Gas propagation following a sudden loss of vacuum in a pipe cooled by He I and He II.
NASA Astrophysics Data System (ADS)
Garceau, N.; Guo, W.; Dodamead, T.
2017-12-01
Many cryogenic systems around the world are concerned with the sudden catastrophic loss of vacuum for cost, preventative damage, safety or other reasons. The experiments in this paper were designed to simulate the sudden vacuum break in the beam-line pipe of a liquid helium cooled superconducting particle accelerator. This paper expands previous research conducted at the National High Magnetic Field Laboratory and evaluates the differences between normal helium (He I) and superfluid helium (He II). For the experiments, a straight pipe and was evacuated and immersed in liquid helium at 4.2 K and below 2.17 K. Vacuum loss was simulated by opening a solenoid valve on a buffer tank filled nitrogen gas. Gas front arrival was observed by a temperature rise of the tube. Preliminary results suggested that the speed of the gas front through the experiment decreased exponentially along the tube for both normal liquid helium and super-fluid helium. The system was modified to a helical pipe system to increase propagation length. Testing and analysis on these two systems revealed there was minor difference between He I and He II despite the difference between the two distinct helium phases heat transfer mechanisms: convection vs thermal counterflow. Furthermore, the results indicated that the temperature of the tube wall above the LHe bath also plays a significant role in the initial front propagation. More systematic measurements are planned in with the helical tube system to further verify the results.
Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu
2011-01-01
A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer's tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1 : 10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity.
Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu
2015-01-01
Objective A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. Methods A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer’s tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1:10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Results Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. Conclusion N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity. PMID:22403982
Dual manifold heat pipe evaporator
Adkins, Douglas R.; Rawlinson, K. Scott
1994-01-01
An improved evaporator section for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes.
High-Voltage, High-Impedance Ion Beam Production
2009-06-01
the anode tube with a loosely-crumpled, thin aluminized- mylar foil. This spoils the virtual cathode and greatly reduces the neutron signal, as seen...ions follow ballistic (straight-line) trajectories in the drift tube (see Sec. VIII), then (except for the small displacement associated with bending...mTorr) ambient in the drift tube . Based on our previous experience, we would expect charge, but not necessarily current, neutralization of the beam
1970-01-01
design and experimentation. I. The Shock- Tube Method Smiley [546] introduced the use of shock waves...one of the greatest disadvantages of this technique. Both the unique adaptability of the shock tube method for high -temperature measurement of...Line-Source Flow Method H. The Hot-Wire Thermal Diffusion Column Method I. The Shock- Tube Method J. The Arc Method K. The Ultrasonic Method .
Variation of the pressure limits of flame propagation with tube diameter for propane-air mixtures
NASA Technical Reports Server (NTRS)
Belles, Frank E; Simon, Dorothy M
1951-01-01
An investigation was made of the variation of the pressure limits of flame propagation with tube diameter for quiescent propane with tube diameter for quiescent propane-air mixtures. Pressure limits were measured in glass tubes of six different inside diameters, with a precise apparatus. Critical diameters for flame propagation were calculated and the effect of pressure was determined. The critical diameters depended on the pressure to the -0.97 power for stoichiometric mixtures. The pressure dependence decreased with decreasing propane concentration. Critical diameters were related to quenching distance, flame speeds, and minimum ignition energy.
Zhao, Ting; Ding, Xinchun; Du, Hong; Yan, Cong
2014-01-01
The underlying mechanisms that lysosomal acid lipase (LAL) deficiency causes infiltration of myeloid-derived suppressor cells (MDSCs) in multiple organs and subsequent inflammation remain incompletely understood. Endothelial cells (ECs), lining the inner layer of blood vessels, constitute barriers regulating leukocytes transmigration to the site of inflammation. Therefore, we hypothesized that ECs are dysfunctional in LAL-deficient (lal−/−) mice. We found that Ly6G+ cells transmigrated more efficiently across lal−/− ECs than wild-type (lal+/+) ECs, which was associated with increased level of platelet endothelial cell adhesion molecule-1 (PECAM-1) and monocyte chemoattractant protein-1 (MCP-1) in lal−/− ECs. In addition, lal−/−ECs showed enhanced migration and proliferation, decreased apoptosis, but impaired tube formation and angiogenesis. lal−/− ECs also suppressed T cell proliferation in vitro. Interestingly, lal−/− Ly6G+ cells promoted in vivo angiogenesis (including a tumor model), EC tube formation and proliferation. Finally, the mammalian target of rapamycin (mTOR) pathway was activated in lal−/− ECs, and inhibition of mTOR reversed EC dysfunctions, including decreasing Ly6G+ cell transmigration, delaying migration, and relieving suppression of T cell proliferation, which was mediated by decreasing production of reactive oxygen species (ROS). Our results indicate that LAL regulates EC functions through interaction with MDSCs and modulation of the mTOR pathway, which may provide a mechanistic basis for targeting MDSCs or mTOR to rejuvenate EC functions in LAL-deficiency related diseases. PMID:25000979
Peng, Wenyan; Yu, Ying; Li, Tiejun; Zhu, Yuanyuan
2013-01-01
Purpose Tissue factor (TF) plays an important role in neovascularization (NV). This study aimed to determine whether small interfering RNA–targeting TF (TF-siRNA) could knock down TF expression and inhibit cell proliferation, cell migration, and tube formation in an in vitro model of NV. Methods Lipopolysaccharide (LPS) was used to stimulate human umbilical vein endothelial cell (HUVEC) lines to express TF and mimic certain phenotypes of NV in vitro. HUVECs were transfected with TF-siRNAs and control siRNAs using LipofectamineTM 2000. The inhibitory effect of the siRNAs on the expression of TF mRNA and protein was evaluated by quantitative reverse transcriptase polymerase chain reaction (RT-qPCR) and western blot analysis. The effects on the cell viability, migration, and tube formation of siRNA-treated cells were examined by MTT assay, wound-healing assay, and Matrigel-induced capillary tube formation. Results Lipopolysaccharide treatment increased the expression of TF. TF-siRNAs effectively knocked down TF expression, with the most efficient TF-siRNA reducing 78.9% of TF expression. TF protein was also notably curtailed by TF-siRNA. The MTT and wound-healing assays showed that the TF-siRNA substantially inhibited the proliferation and migration of HUVECs. Tube formation was decreased by 47.4% and 59.4% in cells treated with the TF-siRNA and vascular endothelial growth factor–siRNA, respectively, compared with the blank control. Conclusions TF-siRNA can knockdown TF expression and inhibit cell proliferation, migration, and tube formation in vitro. TF-siRNA may provide a novel therapeutic candidate for NV-related diseases. PMID:23805036
NASA Technical Reports Server (NTRS)
Clark, B.; Stewart, J. D.
1974-01-01
This experiment was concerned with the effects of rotary acceleration on choice reaction time (RTc) to the motion of a luminous line on a cathode-ray tube. Specifically, it compared the (RTc) to rotary acceleration alone, visual acceleration alone, and simultaneous, double stimulation by both rotary and visual acceleration. Thirteen airline pilots were rotated about an earth-vertical axis in a precision rotation device while they observed a vertical line. The stimuli were 7 rotary and visual accelerations which were matched for rise time. The pilot responded as quickly as possible by displacing a vertical controller to the right or left. The results showed a decreasing (RTc) with increasing acceleration for all conditions, while the (RTc) to rotary motion alone was substantially longer than for all other conditions. The (RTc) to the double stimulation was significantly longer than that for visual acceleration alone.
NASA Astrophysics Data System (ADS)
Quintero Noda, C.; Kato, Y.; Katsukawa, Y.; Oba, T.; de la Cruz Rodríguez, J.; Carlsson, M.; Shimizu, T.; Orozco Suárez, D.; Ruiz Cobo, B.; Kubo, M.; Anan, T.; Ichimoto, K.; Suematsu, Y.
2017-11-01
In this publication, we continue the work started in Quintero Noda et al., examining this time a numerical simulation of a magnetic flux tube concentration. Our goal is to study if the physical phenomena that take place in it, in particular, the magnetic pumping, leaves a specific imprint on the examined spectral lines. We find that the profiles from the interior of the flux tube are periodically doppler shifted following an oscillation pattern that is also reflected in the amplitude of the circular polarization signals. In addition, we analyse the properties of the Stokes profiles at the edges of the flux tube discovering the presence of linear polarization signals for the Ca II lines, although they are weak with an amplitude around 0.5 per cent of the continuum intensity. Finally, we compute the response functions to perturbations in the longitudinal field, and we estimate the field strength using the weak-field approximation. Our results indicate that the height of formation of the spectral lines changes during the magnetic pumping process, which makes the interpretation of the inferred magnetic field strength and its evolution more difficult. These results complement those from previous works, demonstrating the capabilities and limitations of the 850-nm spectrum for chromospheric Zeeman polarimetry in a very dynamic and complex atmosphere.
Powerful glow discharge excilamp
Tarasenko, Victor F.; Panchenko, Aleksey N.; Skakun, Victor S.; Sosnin, Edward A.; Wang, Francis T.; Myers, Booth R.; Adamson, Martyn G.
2002-01-01
A powerful glow discharge lamp comprising two coaxial tubes, the outer tube being optically transparent, with a cathode and anode placed at opposite ends of the tubes, the space between the tubes being filled with working gas. The electrodes are made as cylindrical tumblers placed in line to one other in such a way that one end of the cathode is inserted into the inner tube, one end of the anode coaxially covers the end of the outer tube, the inner tube penetrating and extending through the anode. The increased electrodes' surface area increases glow discharge electron current and, correspondingly, average radiation power of discharge plasma. The inner tube contains at least one cooling liquid tube placed along the axis of the inner tube along the entire lamp length to provide cathode cooling. The anode has a circumferential heat extracting radiator which removes heat from the anode. The invention is related to lighting engineering and can be applied for realization of photostimulated processes under the action of powerful radiation in required spectral range.
Brgoch, M. S.; Dodson, K. M.; Kim, T. C.; Kim, D. M.; Rhodes, J. L.
2015-01-01
Background: Chronic otitis media with effusion is a persistent complication essentially universal in children with cleft palate. The prevalence of chronic otitis media with effusion is hypothesized to be a result of Eustachian tube dysfunction secondary to the anomalous insertion of the palatal musculature. This study was designed to evaluate the timing of tympanostomy tube placement and the effect of primary palatoplasty technique on the recovery of Eustachian tube function and resolution of chronic otitis media with effusion. Methods: We performed a retrospective, cross-sectional analysis of the previous 99 consecutive patients who underwent a palatoplasty at our institution. Variables included timing of initial tympanostomy tube placement, palatoplasty technique, cleft type, and gender. These were then evaluated to assess their impact on the resolution of chronic otitis media with effusion. Resolution was established as an inverse function of the number of tympanostomy tubes placed in correlation with available audiometric/tympanographic data. For all models, a generalized linear mixed model was applied using a Poisson distribution and a log-link function where the outcome variable was the total number of tympanostomy tubes. For all tests, a P = .05 level of significance was used. Results: Of 99 palatoplasties performed, 94 patients were included in the study. Ninety-one percent of patients had documented chronic otitis media with effusion at the time of palatoplasty. Forty-four percent underwent straight-line repair with aggressive intravelar veloplasty, 36% had Furlow double z-plasty, 20% had straight-line repair without intravelar veloplasty. There was a statistically significant difference (F2,83 = 5.36, P = .0065) between the 3 types of repair. The mean number of tubes placed was 0.6000 ± 0.1225, 0.8519 ± 0.1776, and 1.4737 ± 0.2785 for intravelar veloplasty, Furlow double z-plasty, and straight line without intravelar veloplasty, respectively . With regard to the timing of tympanostomy tube placement, there was a trend toward statistical significant (F2,83 = 3.02, P = .0540) in the mean number of tube insertions was 1.4286 ± 0.4518, 0.6964 ± 0.1115, and 1.1304 ± 0.2217 when the initial set was placed before palatoplasty, at the time of palatoplasty, and after palatoplasty, respectively. Conclusions: Despite its inherent limitations, this study suggests that palatal musculature reconstruction via intravelar veloplasty or reorientation via Furlow double z-plasty may improve Eustachian tube function and lower the need for tympanostomy tubes in this population. In comparison with other time points, patients who underwent initial tympanostomy tube placement at the time of palatoplasty trended toward improved chronic otitis media with effusion. PMID:26240670
Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs
NASA Technical Reports Server (NTRS)
Rubin, Leslie; Federico, Frank; Formato, Richard; Larouco, John; Slager, William
2004-01-01
Tubes made from biaxially oriented liquid-crystal polymers (LCPs) have been developed for use as penetrations on cryogenic tanks. ( Penetrations in this context denotes feed lines, vent lines, and sensor tubes, all of which contribute to the undesired conduction of heat into the tanks.) In comparison with corresponding prior cryogenic-tank penetrations made from stainless steels and nickel alloys, the LCP penetrations offer advantages of less weight and less thermal conduction. An additional major advantage of LCP components is that one can tailor their coefficients of thermal expansion (CTEs). The estimated cost of continuous production of LCP tubes of typical sizes is about $1.27/ft ($4.17/m) [based on 1998 prices]. LCP tubes that are compatible with liquid oxygen and that feature tailored biaxial molecular orientation and quasi-isotropic properties (including quasi-isotropic CTE) have been fabricated by a combination of proprietary and patented techniques that involve the use of counterrotating dies (CRDs). Tailoring of the angle of molecular orientation is what makes it possible to tailor the CTE over a wide range to match the CTEs of adjacent penetrations of other tank components; this, in turn, makes it possible to minimize differential-thermal expansion stresses that arise during thermal cycling. The fabrication of biaxially oriented LCP tubes by use of CRDs is not new in itself. The novelty of the present development lies in tailoring the orientations and thus the CTEs and other mechanical properties of the LCPs for the intended cryogenic applications and in modifications of the CRDs for this purpose. The LCP tubes and the 304-stainless-steel tubes that the LCP tubes were intended to supplant were tested with respect to burst strength, permeability, thermal conductivity, and CTE.
Hard- and software problems of spaced meteor observations by optical electronics
NASA Technical Reports Server (NTRS)
Shafiev, R. I.; Mukhamednazarov, S.; Ataev, A. SH.
1987-01-01
An optical electronic facility is being used for meteor observations along with meteor radars and astronomical TV. The main parts of the facility are cameras using UM-92 optical electronic image tubes. The three cascade optical electronic image tube with magnetic focusing has a 40 mm cathode and resolution in the center of up to 30 pairs of lines/mm. The photocathode is of a multislit S-20 type. For meteor spectra observations, replica gratings of 200 and 300 lines/mm are used as the dispersive element.
DEVICE FOR CHARGING OR DISCHARGING
Untemeyer, S.; Hutter, E.
1959-01-13
A loading and unloading device is presented for loading objects into and unloading them from an apparatus in which fluid under pressure is employed, such as a heterogeneous rcactor wherein the fuel elements are in the form of slugs. This device is comprised essentially of a cylindrical member disposed coaxially with and as an accessible extension of an internal tube member of the apparatus in which the objects, or fuel elements, are normally disposed in use. The outermost end of the cylindrical extension is closed by a removable seal plug. The lower end of the cylindrical extension is separated from the intennal tube by a disk valve which is operated externally. A source of pressure fluid and a drain line are provided in communication with the interior of the cylindrical extension. To load an object into the internal tube, the disk valve is closed, the seal plug is renmoved, an object is placed in the cylindrical extension, and the seal plug is replaced. The disk valve is then opened and ihe pressure of the fluid within the cylindrical extension is increased until it is greater than the pressure within the internal tube and forces the object out of the cylindrical extension into the internal tube. To remove an object from the tube the disk valve is opened and the intenior of thc cylindnical extension is connected to the drain line whereby the operating pressure within the intennal tube forces the object out of the internal tube and up into the cylindrical extension. The disk valve is then closed and the seal plug is removed to permit removal of the object.
Anderson, Louis W.; Fitzsimmons, William A.
1978-01-01
A pulsed gas laser is constituted by Blumlein circuits wherein space metal plates function both as capacitors and transmission lines coupling high frequency oscillations to a gas filled laser tube. The tube itself is formed by spaced metal side walls which function as connections to the electrodes to provide for a high frequency, high voltage discharge in the tube to cause the gas to lase. Also shown is a spark gap switch having structural features permitting a long life.
[How to do - the chest tube drainage].
Klopp, Michael; Hoffmann, Hans; Dienemann, Hendrik
2015-03-01
A chest tube is used to drain the contents of the pleural space to reconstitute the physiologic pressures within the pleural space and to allow the lungs to fully expand. Indications for chest tube placement include pneumothorax, hemothorax, pleural effusion, pleural empyema, and major thoracic surgery. The most appropriate site for chest tube placement is the 4th or 5th intercostal space in the mid- or anterior- axillary line. Attention to technique in placing the chest tube is vital to avoid complications from the procedure. Applying the step-by-step technique presented, placement of a chest tube is a quick and safe procedure. Complications - frequently occurring when the tube is inserted with a steel trocar - include hemothorax, dislocation, lung lacerations, and injury to organs in the thoracic or abdominal cavity." © Georg Thieme Verlag KG Stuttgart · New York.
Dual manifold heat pipe evaporator
Adkins, D.R.; Rawlinson, K.S.
1994-01-04
An improved evaporator section is described for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes. 1 figure.
Control of water and nutrients using a porous tube - A method for growing plants in space
NASA Technical Reports Server (NTRS)
Dreschel, Thomas W.; Sager, John C.
1989-01-01
A plant nutrient delivery system that uses a microporous, hydrophilic tube was developed with potential application for crop production in the microgravity of space. The tube contains a nutrient solution and delivers it to the roots. Pumps attached to the tubing create a very small suction that holds the solution within the tube. This system was used to grow wheat for 107 d in a controlled environment at suctions of 0.40, 1.48, or 2.58 kPa. The water absorbed through the pores of the tube by baby diaper sections decreased as suction increased. Correspondingly, final plant biomass, seed number, and spikelet number also tended to decrease as suction increased. The reduced yield at higher suction suggests that the plants experienced water stress, although all suctions were below those typical of soils at field capacity.
O'Doherty, Jim; Chilcott, Anna; Dunn, Joel
2015-11-01
Arterial sampling with dispersion correction is routinely performed for kinetic analysis of PET studies. Because of the the advent of PET-MRI systems, non-MR safe instrumentation will be required to be kept outside the scan room, which requires the length of the tubing between the patient and detector to increase, thus worsening the effects of dispersion. We examined the effects of dispersion in idealized radioactive blood studies using various lengths of tubing (1.5, 3, and 4.5 m) and applied a well-known transmission-dispersion model to attempt to correct the resulting traces. A simulation study was also carried out to examine noise characteristics of the model. The model was applied to patient traces using a 1.5 m acquisition tubing and extended to its use at 3 m. Satisfactory dispersion correction of the blood traces was achieved in the 1.5 m line. Predictions on the basis of experimental measurements, numerical simulations and noise analysis of resulting traces show that corrections of blood data can also be achieved using the 3 m tubing. The effects of dispersion could not be corrected for the 4.5 m line by the selected transmission-dispersion model. On the basis of our setup, correction of dispersion in arterial sampling tubing up to 3 m by the transmission-dispersion model can be performed. The model could not dispersion correct data acquired using a 4.5 m arterial tubing.
Lin, Sue; Dong, Heng; Zhang, Fang; Qiu, Lin; Wang, Fangzhan; Cao, Jiashu; Huang, Li
2014-01-01
Background and Aims The arabinogalactan protein (AGP) gene family is involved in plant reproduction. However, little is known about the function of individual AGP genes in pollen development and pollen tube growth. In this study, Brassica campestris male fertility 8 (BcMF8), a putative AGP-encoding gene previously found to be pollen specific in Chinese cabbage (B. campestris ssp. chinensis), was investigated. Methods Real-time reverse transcription–PCR and in situ hybridization were used to analyse the expression pattern of BcMF8 in pistils. Prokaryotic expression and western blots were used to ensure that BcMF8 could encode a protein. Antisense RNA technology was applied to silence gene expression, and morphological and cytological approaches (e.g. scanning electron microscopy and transmission electron microscopy) were used to reveal abnormal phenotypes caused by gene silencing. Key Results The BcMF8 gene encoded a putative AGP protein that was located in the cell wall, and was expressed in pollen grains and pollen tubes. The functional interruption of BcMF8 by antisense RNA technology resulted in slipper-shaped and bilaterally sunken pollen with abnormal intine development and aperture formation. The inhibition of BcMF8 led to a decrease in the percentage of in vitro pollen germination. In pollen that did germinate, the pollen tubes were unstable, abnormally shaped and burst more frequently relative to controls, which corresponded to an in vivo arrest of pollen germination at the stigma surface and retarded pollen tube growth in the stylar transmitting tissues. Conclusions The phenotypic defects of antisense BcMF8 RNA lines (bcmf8) suggest a crucial function of BcMF8 in modulating the physical nature of the pollen wall and in helping in maintaining the integrity of the pollen tube wall matrix. PMID:24489019
Decreasing Use of Percutaneous Endoscopic Gastrostomy Tube Feeding in Japan.
Komiya, Kosaku; Usagawa, Yuko; Kadota, Jun-Ichi; Ikegami, Naoki
2018-05-25
To identify trends in percutaneous endoscopic gastrostomy (PEG) tube placement and intravenous hyperalimentation (IVH) in nonhospital settings (as a potential alternative to tube feeding for nutrition) and to summarize published reports concerning the decision-making process for PEG placement. National survey and systematic review. Japan. All Japanese people. Data on numbers of individuals with a PEG tube and IVH were obtained from the website of the Japanese Ministry of Health, Labour, and Welfare and published reports concerning the decision-making process for PEG placement in Japan were summarized. The number of PEG tube placements peaked in 2007 and has been decreasing since Japan experienced the Great East Japan Earthquake in 2011. A further decline was seen in 2015 after the Japanese Ministry of Health, Labour and Welfare revised the fee schedule in 2014. More than half of individuals who had tubes were aged 80 and older during the years observed. In contrast, the number of individuals receiving IVH was lowest in the same year as PEG tube placement peaked and has been increasing ever since. Four studies reported that the decision-making process included consideration of not only the underlying disease, but also the individual's age and social barriers and the physician's personal philosophy. The number of PEG tube placements has been decreasing since its peak in 2007, and the number of individuals receiving IVH has been increasing. Many factors influence the decision-making process for PEG tube placement. Physicians in Japan may be realizing that there is little evidence to support the use of tube feeding in frail elderly adults. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.
78 FR 9796 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-12
... against the right steering tube assembly during rudder pedal actuation. This AD requires you to install... between the fuel return line assembly and the steering tube assembly and clearance between the fuel return...://www.cessnasupport.com . You may review copies of the referenced service information at the FAA, Small...
Reading between the Lines: Accessing Information via "Youtube's" Automatic Captioning
ERIC Educational Resources Information Center
Smith, Chad; Allman, Tamby; Crocker, Samantha
2017-01-01
This study and discussion center upon the use of "YouTube's" automatic captioning feature with college-age adult readers. The study required 75 participants with college experience to view brief middle school science videos with automatic captioning on "YouTube" and answer comprehension questions based on material presented…
30 CFR 75.331 - Auxiliary fans and tubing.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (a) When auxiliary fans and tubing are used for face ventilation, each auxiliary fan shall be— (1... auxiliary fan is stopped— (1) Line brattice or other face ventilation control devices shall be used to maintain ventilation to affected faces; and (2) Electrical equipment in the affected working places shall...
30 CFR 75.331 - Auxiliary fans and tubing.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (a) When auxiliary fans and tubing are used for face ventilation, each auxiliary fan shall be— (1... auxiliary fan is stopped— (1) Line brattice or other face ventilation control devices shall be used to maintain ventilation to affected faces; and (2) Electrical equipment in the affected working places shall...
30 CFR 75.331 - Auxiliary fans and tubing.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (a) When auxiliary fans and tubing are used for face ventilation, each auxiliary fan shall be— (1... auxiliary fan is stopped— (1) Line brattice or other face ventilation control devices shall be used to maintain ventilation to affected faces; and (2) Electrical equipment in the affected working places shall...
Dumont, Marie; Lehner, Arnaud; Bouton, Sophie; Kiefer-Meyer, Marie Christine; Voxeur, Aline; Pelloux, Jérôme; Lerouge, Patrice; Mollet, Jean-Claude
2014-10-01
Rhamnogalacturonan-II (RG-II) is one of the pectin motifs found in the cell wall of all land plants. It contains sugars such as 2-keto-3-deoxy-d-lyxo-heptulosaric acid (Dha) and 2-keto-3-deoxy-d-manno-octulosonic acid (Kdo), and within the wall RG-II is mostly found as a dimer via a borate diester cross-link. To date, little is known regarding the biosynthesis of this motif. Here, after a brief review of our current knowledge on RG-II structure, biosynthesis and function in plants, this study explores the implications of the presence of a Golgi-localized sialyltransferase-like 2 (SIA2) protein that is possibly involved in the transfer of Dha or Kdo in the RG-II of Arabidopsis thaliana pollen tubes, a fast-growing cell type used as a model for the study of cell elongation. Two heterozygous mutant lines of arabidopsis (sia2-1+/- and qrt1 × sia2-2+/-) were investigated. sia2-2+/- was in a quartet1 background and the inserted T-DNA contained the reporter gene β-glucuronidase (GUS) under the pollen-specific promoter LAT52. Pollen germination and pollen tube phenotype and growth were analysed both in vitro and in vivo by microscopy. Self-pollination of heterozygous lines produced no homozygous plants in the progeny, which may suggest that the mutation could be lethal. Heterozygous mutants displayed a much lower germination rate overall and exhibited a substantial delay in germination (20 h of delay to reach 30 % of pollen grain germination compared with the wild type). In both lines, mutant pollen grains that were able to produce a tube had tubes that were either bursting, abnormal (swollen or dichotomous branching tip) or much shorter compared with wild-type pollen tubes. In vivo, mutant pollen tubes were restricted to the style, whereas the wild-type pollen tubes were detected at the base of the ovary. This study highlights that the mutation in arabidopsis SIA2 encoding a sialyltransferase-like protein that may transfer Dha or Kdo on the RG-II motif has a dramatic effect on the stability of the pollen tube cell wall. © The Author 2014. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
50 CFR 229.32 - Atlantic large whale take reduction plan regulations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... marked with thin colored whipping line, thin colored plastic, or heat-shrink tubing, or other material... be dyed, painted, or marked with thin colored whipping line, thin colored plastic, or heat-shrink...
50 CFR 229.32 - Atlantic large whale take reduction plan regulations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... marked with thin colored whipping line, thin colored plastic, or heat-shrink tubing, or other material... be dyed, painted, or marked with thin colored whipping line, thin colored plastic, or heat-shrink...
Flooding Experiments and Modeling for Improved Reactor Safety
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solmos, M.; Hogan, K. J.; Vierow, K.
2008-09-14
Countercurrent two-phase flow and “flooding” phenomena in light water reactor systems are being investigated experimentally and analytically to improve reactor safety of current and future reactors. The aspects that will be better clarified are the effects of condensation and tube inclination on flooding in large diameter tubes. The current project aims to improve the level of understanding of flooding mechanisms and to develop an analysis model for more accurate evaluations of flooding in the pressurizer surge line of a Pressurized Water Reactor (PWR). Interest in flooding has recently increased because Countercurrent Flow Limitation (CCFL) in the AP600 pressurizer surge linemore » can affect the vessel refill rate following a small break LOCA and because analysis of hypothetical severe accidents with the current flooding models in reactor safety codes shows that these models represent the largest uncertainty in analysis of steam generator tube creep rupture. During a hypothetical station blackout without auxiliary feedwater recovery, should the hot leg become voided, the pressurizer liquid will drain to the hot leg and flooding may occur in the surge line. The flooding model heavily influences the pressurizer emptying rate and the potential for surge line structural failure due to overheating and creep rupture. The air-water test results in vertical tubes are presented in this paper along with a semi-empirical correlation for the onset of flooding. The unique aspects of the study include careful experimentation on large-diameter tubes and an integrated program in which air-water testing provides benchmark knowledge and visualization data from which to conduct steam-water testing.« less
Stakeholder Values and Perspectives when Implementing Led Lights on Navy Ships
2014-06-01
Additionally, the M1 IntelliTube is a retrofit lamp , 32 which works with line power or any of the legacy ballasts.” ( LED /IntelliTube NAVSEA: LED ...only factor taken into consideration, then break-even point for LED lighting, Navy- wide, is approximately one hour to change the lamp . Of note...Energy Focus. (2013, July 3). Energy Focus: Specifications: IntelliTube LED replacement lamp , 24”, T12 LED lamp . Retrieved from http
Zhang, Qiyang; Gong, Maojun
2014-01-01
Integrated microfluidic systems coupled with electrophoretic separations have broad application in biological and chemical analysis. Interfaces for the connection of various functional parts play a major role in the performance of a system. Here we developed a rapid prototyping method to fabricate monolithic poly(dimethylsiloxane) (PDMS) Interfaces for flow-gated injection, online reagent mixing, and tube-to-tube connection in an integrated capillary electrophoresis (CE) system. The basic idea was based on the properties of PDMS: elasticity, transparency, and suitability for prototyping. The molds for these interfaces were prepared by using commercially available stainless steel wires and nylon lines or silica capillaries. A steel wire was inserted through the diameter of a nylon line and a cross format was obtained as the mold for PDMS casting of flow gates and 4-way mixers. These interfaces accommodated tubing connection through PDMS elasticity and provided easy visual trouble shooting. The flow gate used smaller channel diameters thus reducing flow rate by 25 fold for effective gating compared with mechanically machined counterparts. Both PDMS mixers and the tube-to-tube connectors could minimize the sample dead volume by using an appropriate capillary configuration. As a whole, the prototyped PDMS interfaces are reusable, inexpensive, convenient for connection, and robust when integrated with the CE detection system. Therefore, these interfaces could see potential applications in CE and CE-coupled systems. PMID:24331370
Goldberg, David A.; Flood, William S.; Arthur, Allan A.; Voelker, Ferdinand
1986-01-01
A broad-band beam buncher is disclosed, comprising an evacuated housing, an electron gun therein for producing an electron beam, a buncher cavity having entrance and exit openings through which the beam is directed, grids across such openings, a source providing a positive DC voltage between the cavity and the electron gun, a drift tube through which the electron beam travels in passing through such cavity, grids across the ends of such drift tube, gaps being provided between the drift tube grids and the entrance and exit grids, a modulator for supplying an ultrahigh frequency modulating signal to the drift tube for producing velocity modulation of the electrons in the beam, a drift space in the housing through which the velocity modulated electron beam travels and in which the beam is bunched, and a discharge opening from such drift tube and having a grid across such opening through which the bunched electron beam is discharged into an accelerator or the like. The buncher cavity and the drift tube may be arranged to constitute an extension of a coaxial transmission line which is employed to deliver the modulating signal from a signal source. The extended transmission line may be terminated in its characteristic impedance to afford a broad-band response and the device as a whole designed to effect broad-band beam coupling, so as to minimize variations of the output across the response band.
Álvarez, José M; Cortizo, Millán; Ordás, Ricardo J
2012-01-01
Pinus pinaster is one of the most economically important conifers in the world. Somatic embryogenesis is a powerful tool in breeding programmes because it allows the generation of a great number of different clonal lines from seeds of superior genotypes. Unfortunately, embryogenic competence decreases with the age of cultures. Therefore, it is necessary to have a cryopreservation protocol that ensures a continuous supply of juvenile mass while allowing good maturation and conversion rates into vigorously growing plants. In this work we studied the influence of several cryopreservation parameters, such as cryoprotectant solution and pre-cooling temperature, on embryogenic culture regrowth and embryo maturation. Recovery of rewarmed samples after cryopreservation in a -150 degree C freezer depended on the cooling temperature reached prior to plunging the tubes into liquid nitrogen. As a result, we present an optimised cryopreservation protocol that ensures high recovery and embryo maturation rates. The protocol presented is a simple and fast alternative and enabled successful cryopreservation and recovery of 100 percent of the lines tested. Cryopreserved lines presented the same maturation rates as non-cryopreserved controls.
Automating data analysis during the inspection of boiler tubes using line scanning thermography
NASA Astrophysics Data System (ADS)
Ley, Obdulia; Momeni, Sepand; Ostroff, Jason; Godinez, Valery
2012-05-01
Failures in boiler waterwalls can occur when a relatively small amount of corrosion and loss of metal have been experienced. This study presents our efforts towards the application of Line Scanning Thermography (LST) for the analysis of thinning in boiler waterwall tubing. LST utilizes a line heat source to thermally excite the surface to be inspected and an infrared detector to record the transient surface temperature increase observed due to the presence of voids, thinning or other defects. In waterwall boiler tubes the defects that can be detected using LST correspond to corrosion pitting, hydrogen damage and wall thinning produced by inadequate burner heating or problems with the water chemistry. In this paper we discuss how the LST technique is implemented to determine thickness from the surface temperature data, and we describe our efforts towards developing a semiautomatic analysis tool to speed up the time between scanning, reporting and implementing repairs. We compare the density of data produced by the common techniques used to assess wall thickness and the data produced by LST.
Fuel cell tubes and method of making same
Borglum, Brian P.
1999-11-30
A method of manufacturing porous ceramic tubes for fuel cells with improved properties and higher manufacturing yield is disclosed. The method involves extruding a closed end fuel cell tube, such as an air electrode of a solid oxide fuel cell, in which the closed end also functions as the sintering support. The resultant fuel cell tube has a superior porosity distribution which allows improved diffusion of oxygen at the closed end of the tube during operation of the fuel cell. Because this region has the highest current density, performance enhancement and improved reliability of the fuel cell tube result. Furthermore, the higher manufacturing yield associated with the present method decreases the overall fuel cell cost. A method of manufacturing porous ceramic tubes for fuel cells with improved properties and higher manufacturing yield is disclosed. The method involves extruding a closed end fuel cell tube, such as an air electrode of a solid oxide fuel cell, in which the closed end also functions as the sintering support. The resultant fuel cell tube has a superior porosity distribution which allows improved diffusion of oxygen at the closed end of the tube during operation of the fuel cell. Because this region has the highest current density, performance enhancement and improved reliability of the fuel cell tube result. Furthermore, the higher manufacturing yield associated with the present method decreases the overall fuel cell cost.
Dynamics of Magnetic Flux Tubes in an Advective Flow around a Black Hole
NASA Astrophysics Data System (ADS)
Deb, Arnab; Chakrabarti, Sandip Kumar; Giri, Kinsuk
2016-07-01
Magnetic fields cannibalized by an accretion flow would very soon have a dominant toroidal component. Without changing the topology, we study the movements of these flux tubes inside a geometrically thick advective disk which undergo centrifugal pressure supported shocks. We also consider the effects of the flux tubes on the flow. We use a finite element method (Total Variation Diminishing) for this purpose and specifically focussed whether the flux tubes contribute to changes in outflow properties in terms of its collimation and outflow rates. It is seen that depending upon the cross sectional radius of the flux tubes (which control the drag force), these field lines may move towards the central object or oscillate vertically before eventually escaping out of the funnel wall (pressure zero surface). These interesting results obtained with and without flux tubes point to the role the flux tubes play in collimation of jets and outflows.
Guzman, Marco; Laukkanen, Anne-Maria; Traser, Louisa; Geneid, Ahmed; Richter, Bernhard; Muñoz, Daniel; Echternach, Matthias
2017-10-01
This study investigated the influence of tube phonation into water on vocal fold vibration. Eight participants were analyzed via high-speed digital imaging while phonating into a silicon tube with the free end submerged into water. Two test sequences were studied: (1) phonation pre, during, and post tube submerged 5 cm into water; and (2) phonation into tube submerged 5 cm, 10 cm, and 18 cm into water. Several glottal area parameters were calculated using phonovibrograms. The results showed individual differences. However, certain trends were possible to identify based on similar results found for the majority of participants. Amplitude-to-length ratio, harmonic-to-noise ratio, and spectral flatness (derived from glottal area) decreased for all tube immersion depths, while glottal closing quotient increased for 10 cm immersion and contact quotient for 18 cm immersion. Closed quotient decreased during phonation into the tube at 5 cm depth, and jitter decreased during and after it. Results suggest that the depth of tube submersion appears to have an effect on phonation. Shallow immersion seems to promote smoother and more stable phonation, while deeper immersion may involve increased respiratory and glottal effort to compensate for the increased supraglottal resistance. This disparity, which is dependent upon the degree of flow resistance, should be considered when choosing treatment exercises for patients with various diagnoses, namely hyperfunctional or hypofunctional dysphonia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inoue, S.; Magara, T.; Choe, G. S.
2015-04-20
We clarify a relationship between the dynamics of a solar flare and a growing coronal mass ejection (CME) by investigating the dynamics of magnetic fields during the X2.2-class flare taking place in the solar active region 11158 on 2011 February 15, based on simulation results obtained from Inoue et al. We found that the strongly twisted lines formed through tether-cutting reconnection in the twisted lines of a nonlinear force-free field can break the force balance within the magnetic field, resulting in their launch from the solar surface. We further discover that a large-scale flux tube is formed during the eruptionmore » as a result of the tether-cutting reconnection between the eruptive strongly twisted lines and these ambient weakly twisted lines. The newly formed large flux tube exceeds the critical height of the torus instability. Tether-cutting reconnection thus plays an important role in the triggering of a CME. Furthermore, we found that the tangential fields at the solar surface illustrate different phases in the formation of the flux tube and its ascending phase over the threshold of the torus instability. We will discuss these dynamics in detail.« less
Line focus x-ray tubes—a new concept to produce high brilliance x-rays
NASA Astrophysics Data System (ADS)
Bartzsch, Stefan; Oelfke, Uwe
2017-11-01
Currently hard coherent x-ray radiation at high photon fluxes can only be produced with large and expensive radiation sources, such as 3rd generation synchrotrons. Especially in medicine, this limitation prevents various promising developments in imaging and therapy from being translated into clinical practice. Here we present a new concept of highly brilliant x-ray sources, line focus x-ray tubes (LFXTs), which may serve as a powerful and cheap alternative to synchrotrons and a range of other existing technologies. LFXTs employ an extremely thin focal spot and a rapidly rotating target for the electron beam which causes a change in the physical mechanism of target heating, allowing higher electron beam intensities at the focal spot. Monte Carlo simulations and numeric solutions of the heat equation are used to predict the characteristics of the LFXT. In terms of photon flux and coherence length, the performance of the line focus x-ray tube compares with inverse Compton scattering sources. Dose rates of up to 180 Gy s-1 can be reached in 50 cm distance from the focal spot. The results demonstrate that the line focus tube can serve as a powerful compact source for phase contrast imaging and microbeam radiation therapy. The production of a prototype seems technically feasible.
NASA Astrophysics Data System (ADS)
Kim, Young Sik; Park, Sujin; Chang, Hyun Young
2014-01-01
When sea water was used as cooling water for water condenser of nuclear power plants, commercial stainless steels can not be applied because chloride concentration exceeds 20,000 ppm. There are many opinions for the materials selection of tube and tube sheets of a condenser. This work reviewed the application guide line of stainless steels for sea-water facilities and the estimation equations of lifespan were proposed from the analyses of both field data for sea water condenser and experimental results of corrosion. Empirical equations for lifespan estimation were derived from the pit initiation time and re-tubing time of stainless steel tubing in sea water condenser of nuclear power plants. The lifespan of seal-welded super austenitic stainless steel tube/tube sheet was calculated from these equations. Critical pitting temperature of seal-welded PRE 50 grade super stainless steel was evaluated as 60 °C. Using the proposed equation in engineering aspect, tube pitting corrosion time of seal-welded tube/tube sheet was calculated as 69.8 years and re-tubing time was estimated as 82.0 years.
Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.
Porcel, José M
2018-04-01
Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.
Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists
2018-01-01
Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629
Kellie, Scott P; Scott, Michael J; Cavallazzi, Rodrigo; Wiemken, Tim L; Goss, Linda; Parker, Deanna; Saad, Mohamed
2014-01-01
Implementing best practice guidelines for ventilator-associated pneumonia (VAP) and central line-associated blood stream infection (CLA-BSI) has variable success. Our institution was concerned with high rates of VAP and CLA-BSI. This retrospective study was undertaken to see whether implementation of the below practices would reduce the rates of VAP and CLA-BSI without resorting to more expensive interventions such as subglottic endotracheal (ET) tube suctioning or silver-impregnated ET tubes. We utilized easily collectable data (standardized infection ratios [SIRs]) to rapidly assess whether interventions already in place were successful. This avoided cumbersome data collection and review. Retrospective data review calculated SIRs using National Healthcare Safety Network benchmarks. Rates and SIRs were compared using z tests with P values <.05 considered statistically significant. This data review attempted to examine the impact of education campaigns, staff meetings, in-services, physician checklist, nurse checklist, charge nurse checklist implementation, and chlorhexidine gluconate oral care addition to the VAP bundle. Additionally, central line insertion required nursing supervision, a checklist, and physician signature. The incidence rate of VAP went from 9.88 occurrences/1000 vent days in 2009 to 0 occurrences/1000 vent days in 2010 (P < .001). The CLA-BSI occurrences/1000 line days were 2.86 in 2009 and 0.97 in 2010 (P = .0187). The SIR for VAP was 4.12 in 2009 and 0 in 2010 (P < .001). For CLA-BSI, the SIR was 1.1 in 2009 and 0.37 in 2010 (P = .04). Efforts to improve physician, patient, and staff education, and checklist implementation resulted in a decrease in VAP and CLA-BSI. This study confirms the applicability of best practice guidelines and suggests a benefit to the use of checklists. We utilize a practical approach for examining the success of these changes.
Interchange Slip-Running Reconnection and Sweeping SEP-Beams
NASA Technical Reports Server (NTRS)
Masson, S.; Aulanier, G.; Pariat, E.; Klein, K.-L.
2011-01-01
We present a new model to explain how particles, accelerated at a reconnection site that is not magnetically connected to the Earth, could eventually propagate along the well-connected open flux tube. Our model is based on the results of a low-beta resistive magnetohydrodynamics simulation of a three-dimensional line-tied and initially current-free bipole, that is embedded in a non-uniform open potential field. The topology of this configuration is that of an asymmetric coronal null-point, with a closed fan surface and an open outer spine. When driven by slow photospheric shearing motions, field lines, initially fully anchored below the fan dome, reconnect at the null point, and jump to the open magnetic domain. This is the standard interchange mode as sketched and calculated in 2D. The key result in 3D is that, reconnected open field lines located in the vicinity of the outer spine, keep reconnecting continuously, across an open quasi-separatrix layer, as previously identified for non-open-null-point reconnection. The apparent slipping motion of these field lines leads to form an extended narrow magnetic flux tube at high altitude. Because of the slip-running reconnection, we conjecture that if energetic particles would be travelling through, or be accelerated inside, the diffusion region, they would be successively injected along continuously reconnecting field lines that are connected farther and farther from the spine. At the scale of the full Sun, owing to the super-radial expansion of field lines below 3 solar radius, such energetic particles could easily be injected in field lines slipping over significant distances, and could eventually reach the distant flux tube that is well-connected to the Earth.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-10
... Carbon and Alloy Seamless Standard, Line, and Pressure Pipe From Japan: Extension of Time Limit for... review of the antidumping duty order on certain large diameter carbon and alloy seamless standard, line... manufacturers/exporters: JFE Steel Corporation; Nippon Steel Corporation; NKK Tubes; and Sumitomo Metal...
Novel plasma source for safe beryllium spectral line studies in the presence of beryllium dust
NASA Astrophysics Data System (ADS)
Stankov, B. D.; Vinić, M.; Gavrilović Božović, M. R.; Ivković, M.
2018-05-01
Plasma source for beryllium spectral line studies in the presence of beryllium dust particles was realised. The guideline during construction was to prevent exposure to formed dust, considering the toxicity of beryllium. Plasma source characterization through determination of optimal working conditions is described. The necessary conditions for Be spectral line appearance and optimal conditions for line shape measurements are found. It is proven experimentally that under these conditions dust appears coincidently with the second current maximum. The electron density measured after discharge current maximum is determined from the peak separation of the hydrogen Balmer beta spectral line, and the electron temperature is determined from the ratios of the relative intensities of Be spectral lines emitted from successive ionized stages of atoms. Maximum values of electron density and temperature are measured to be 9.3 × 1022 m-3 and 16 800 K, respectively. Construction details and testing of the BeO discharge tube in comparison with SiO2 and Al2O3 discharge tubes are also presented in this paper.
Recent Development Status of Stirling Type Pulse Tube Cryocooler for HTS
NASA Astrophysics Data System (ADS)
Hiratsuka, Y.; Nakano, K.; Kato, T.
2014-05-01
Sumitomo Heavy Industries, Ltd. (SHI) has been developing a high power stirling type pulse tube cryocooler. For the purpose of cooling high-temperature superconductor (HTS) devices, such as superconductor motor, SMES and current fault limiter, requested specifications from the devices to a cryocooler are compact size, light weight, high efficiency and high reliability. Especially, the cryocooler must be demanded COP > 0.1 in the efficiency. The experimental results of prototype pulse tube cryocooler were reported in June 2012 [1]. For an In-line type expander, the cooling capacity was 210 W at 77 K and the minimum temperature was 37 K when the compressor input power was 3.8 kW and the operating frequency was 49 Hz. Accordingly, COP was about 0.055. Moreover, for miniaturization a U type expander was tested and the performance is about 10 % less than that of an In-line type expander. After that, we have estimated that the cooling performance is influenced by the environment such as the effect of the pulse-tube inclination, the temperature and the flowing quantity of cooling water. The detailed results are reported in this paper.
The evaluation of energy efficiency of convective heat transfer surfaces in tube bundles
NASA Astrophysics Data System (ADS)
Grigoriev, B. A.; Pronin, V. A.; Salohin, V. I.; Sidenkov, D. V.
2017-11-01
When evaluating the effectiveness of the heat exchange surfaces in the main considered characteristics such as heat flow (Q, Watt), the power required for pumps (N, Watt), and surface area of heat transfer (F, m2). The most correct comparison provides a comparison “ceteris paribus”. Carried out performance comparison “ceteris paribus” in-line and staggered configurations of bundles with a circular pipes can serve as a basis for the development of physical models of flow and heat transfer in tube bundles with tubes of other geometric shapes, considering intertubular stream with attached eddies. The effect of longitudinal and transverse steps of the pipes on the energy efficiency of different configurations would take into account by mean of physical relations between the structure of shell side flow with attached eddies and intensity of transfer processes of heat and momentum. With the aim of energy-efficient placement of tubes, such an approach opens up great opportunities for the synthesis of a plurality of tubular heat exchange surfaces, in particular, the layout of the twisted and in-line-diffuser type with a drop-shaped pipes.
Modulators for the S-band test linac at DESY
NASA Astrophysics Data System (ADS)
Bieler, M.; Choroba, S.; Hameister, J.; Lewin, H.-Ch.
1995-07-01
The development of adequate modulators for high peak power klystrons is one of the focus points for linear collider R&D programs. For the DESY/THD S-band linear collider study 150 MW rf-pulse power at 50 Hz repetition rate and 3 μs pulse duration is required [1]. Two different modulator schemes are under investigation. One is the conventional line type pulser, using a pulse forming network and a step up transformer, the other one is a hard tube pulser, using a dc power source at the full klystron voltage and a switch tube. This paper is focused on the modulator development for the S-band Test Linac at DESY. After a short overview over the test linac and a brief description of the 150 MW S-band klystron the circuitry of the line type pulse (LTP) is given. A hard tube pulser (HTP), which switches the high voltage directly from a storage capacitor to the klystron, has been built up at DESY. Circuitry and the results of the commissioning of the switch tube are reported.
The Effect of Condensate Inundation on Steam Condensation Heat Transfer in a Tube Bundle.
1985-06-01
predicted by Nusselt [Ref. 10] were measured. This increase was attributed to the effect of surface tension drawing the condensate to the wire and acting...analysis of film condensation on a horizontal tube was set forth by Nusselt in 1916. His analy- sis was, however, for laminar film condensation on a single...temperature. Jakob [Ref. 17] extended the Nusselt analysis to film condensation on a vertical in-line column of horizontal tubes by assuming that all
Observation of a Coulomb flux tube
NASA Astrophysics Data System (ADS)
Greensite, Jeff; Chung, Kristian
2018-03-01
In Coulomb gauge there is a longitudinal color electric field associated with a static quark-antiquark pair. We have measured the spatial distribution of this field, and find that it falls off exponentially with transverse distance from a line joining the two quarks. In other words there is a Coulomb flux tube, with a width that is somewhat smaller than that of the minimal energy flux tube associated with the asymptotic string tension. A confinement criterion for gauge theories with matter fields is also proposed.
NASA Technical Reports Server (NTRS)
Buzzard, R. J.; Metroka, R. R.
1974-01-01
The effects were studied of a thin tungsten liner on the tensile properties of T-111 tubing considered for fuel cladding in a space power nuclear reactor concept. The results indicate that the metallurgically bonded liner had no appreciable effects on the properties of the T-111 tubing. A hot isostatic pressing method used to apply the liners is described along with a means for overcoming the possible embrittling effects of hydrogen contamination.
Stackable In-Line Surface Missile Launch System for a Modular Payload Bay
2004-11-08
stacked modules 14 are connected 8 and sealed to form a single long continuous missile tube . 9 Flexible seals may be used at the base of each missile...vehicles, such as missiles, 22 both through vertical launch via specialized launch tubes on the 23 submarine, and horizontal launch via the submarine’s...torpedo 24 tubes . In some cases, the missiles are quite large, such as the 1 1 Tomahawk missile, which requires sufficient support for the 2 large
Device and method for shortening reactor process tubes
Frantz, C.E.; Alexander, W.K.; Lander, W.E.B.
A device and method are described for in situ shortening of nuclear reactor zirconium alloy process tubes which have grown as a result of radiation exposure. An upsetting technique is utilized which involves inductively heating a short band of a process tube with simultaneous application of an axial load sufficient to cause upsetting with an attendant decrease in length of the process tube.
The Successful Treatment of Pulmonary Pleomorphic Carcinoma with Pembrolizumab: A Case Report
Matsumoto, Yoko; Miura, Tamaki; Horiuchi, Hajime; Usui, Kazuhiro
2017-01-01
Pulmonary pleomorphic carcinomas are rare malignant tumors, and no standard treatments have been established. We herein report the successful treatment of a patient with pulmonary pleomorphic carcinoma with pembrolizumab. A 51-year-old man who was a current smoker presented to our hospital due to dyspnea and hemosputum. Chest X-ray showed right-sided pneumothorax with pleural effusion; chest tube drainage was therefore performed. Computed tomography after chest tube drainage showed a cavitary nodule in the right upper lobe and right hilar and bilateral mediastinal lymphadenopathy. Surgery was performed for the diagnosis and treatment. He was eventually diagnosed with pulmonary pleomorphic carcinoma corresponding to clinical stage IVB (cT2aN2M1c [PLE, ADR, HEP]). The giant cells strongly expressed programmed death ligand-1, and the tumor proportion score was more than 50%. Therefore, pembrolizumab was introduced as the first-line therapy. After 3 cycles of pembrolizumab, his right hilar and bilateral mediastinal lymphadenopathy and pleural dissemination notably decreased. Pembrolizumab might be an effective therapy for pulmonary pleomorphic carcinoma. PMID:28878661
Chest tube management following pulmonary lobectomy: change of protocol results in fewer air leaks.
Bertholet, Joost W M; Joosten, Joris J A; Keemers-Gels, Mariël E; van den Wildenberg, Frits J H; Barendregt, Wouter B
2011-01-01
Much controversy exists regarding the management of chest tubes following pulmonary lobectomy. The objective of this study was to analyse the effect of a new chest tube management protocol on clinical features, such as postoperative air leak, drain characteristics, 30-day postoperative complications and length of hospital stay. We retrospectively analysed 133 patients who underwent pulmonary lobectomy, from January 2005 to December 2008. A new chest tube protocol was introduced on 1 January 2007 and included placement of a single chest tube and early conversion to water seal. The chest tube was removed when air leak had resolved and (non-chylous) fluid drainage was <400 ml/day. The results of patients in the old (n=68) and the new protocol (n=65) were compared. In the new protocol group the median duration of air leak and duration of chest tube drainage declined significantly. Also the length of hospital stay decreased significantly to a median of eight days. The number of reinterventions and 30-day morbidity and mortality rates did not differ significantly. Our data suggest that placement of a single chest tube and early conversion to water seal decreases the duration of air leak and chest tube drainage and length of hospital stay.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Jia; Duan Xinhui; Christner, Jodie A.
2011-11-15
Purpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, organ-based tube current modulation (TCM) and global tube current reduction. Methods: Semi-anthropomorphic thorax phantoms of four different sizes (15, 30, 35, and 40 cm lateral width) were used for dose measurement and image quality assessment. Four scans were performed on each phantom using 100 or 120 kV with a clinical CT scanner: (1) reference scan; (2) scan with bismuth breast shield of an appropriate thickness; (3) scan with organ-based TCM; and (4)more » scan with a global reduction in tube current chosen to match the dose reduction from bismuth shielding. Dose to the breast was measured with an ion chamber on the surface of the phantom. Image quality was evaluated by measuring the mean and standard deviation of CT numbers within the lung and heart regions. Results: Compared to the reference scan, dose to the breast region was decreased by about 21% for the 15-cm phantom with a pediatric (2-ply) shield and by about 37% for the 30, 35, and 40-cm phantoms with adult (4-ply) shields. Organ-based TCM decreased the dose by 12% for the 15-cm phantom, and 34-39% for the 30, 35, and 40-cm phantoms. Global lowering of the tube current reduced breast dose by 23% for the 15-cm phantom and 39% for the 30, 35, and 40-cm phantoms. In phantoms of all four sizes, image noise was increased in both the lung and heart regions with bismuth shielding. No significant increase in noise was observed with organ-based TCM. Decreasing tube current globally led to similar noise increases as bismuth shielding. Streak and beam hardening artifacts, and a resulting artifactual increase in CT numbers, were observed for scans with bismuth shields, but not for organ-based TCM or global tube current reduction. Conclusions: Organ-based TCM produces dose reduction to the breast similar to that achieved with bismuth shielding for both pediatric and adult phantoms. However, organ-based TCM does not affect image noise or CT number accuracy, both of which are adversely affected by bismuth shielding. Alternatively, globally decreasing the tube current can produce the same dose reduction to the breast as bismuth shielding, with a similar noise increase, yet without the streak artifacts and CT number errors caused by the bismuth shields. Moreover, globally decreasing the tube current reduces the dose to all tissues scanned, not simply to the breast.« less
Biocompatibility of Tygon® tubing in microfluidic cell culture.
Jiang, Xiao; Jeffries, Rex E; Acosta, Miguel A; Tikunov, Andrey P; Macdonald, Jeffrey M; Walker, Glenn M; Gamcsik, Michael P
2015-02-01
Growth of the MDA-MB-231 breast cancer cell line in microfluidic channels was inhibited when culture media was delivered to the channels via microbore Tygon® tubing. Culture media incubated within this tubing also inhibited growth of these cells in conventional 96-well plates. These detrimental effects were not due to depletion of critical nutrients due to adsorption of media components onto the tubing surface. A pH change was also ruled out as a cause. Nuclear magnetic resonance spectroscopy of the cell growth media before and after incubation in the tubing confirmed no detectable loss of media components but did detect the presence of additional unidentified signals in the aliphatic region of the spectrum. These results indicate leaching of a chemical species from microbore Tygon® tubing that can affect cell growth in microfluidic devices.
White Thrombus Formation in Blood Tubing Lines in a Chronic Hemodialysis Unit
Watnick, Suzanne; Stooksbury, Michael; Winter, Rolf; Riscoe, Michael; Cohen, David M.
2008-01-01
Background and objectives: Previous reports have described white particulate matter in banked blood components, but no prior public reports describe such matter in blood tubing during the course of routine in-center hemodialysis. This report describes the events, investigations, and preliminary conclusions associated with the spontaneous formation of adherent white thrombus in the venous and arterial blood lines during routine in-center hemodialysis treatments. Design setting, participants, & measurements: This investigation occurred at the Portland Veterans Administration Medical Center (PVAMC) Hemodialysis Unit from October 2006 through April 2007. Sixty-eight variables regarding demographics, medical history and dialysis treatments were collected on our 34 chronic hemodialysis outpatients. Results: Over a 5-wk interval, 62% (21 of 34) of the chronic hemodialysis patients unexpectedly developed a white precipitate adhering to the lumenal surface of their dialysis blood tubing, with 73 of 580 chronic dialysis treatments exhibiting the phenomenon. Microscopic and biochemical analyses were consistent with white thrombus, formed by an aggregation of platelets and fibrin. An alert was issued and other in-center hemodialysis units noted similar findings. This was remedied by the removal of specific tubing. Conclusions: Both patient-specific and tubing-specific factors may have been operative. Although patient safety was not adversely affected, assessment of clinical and manufacturing variables potentially affecting platelet activation is warranted. PMID:18184880
White thrombus formation in blood tubing lines in a chronic hemodialysis unit.
Watnick, Suzanne; Stooksbury, Michael; Winter, Rolf; Riscoe, Michael; Cohen, David M
2008-03-01
Previous reports have described white particulate matter in banked blood components, but no prior public reports describe such matter in blood tubing during the course of routine in-center hemodialysis. This report describes the events, investigations, and preliminary conclusions associated with the spontaneous formation of adherent white thrombus in the venous and arterial blood lines during routine in-center hemodialysis treatments. Design setting, participants, & measurements: This investigation occurred at the Portland Veterans Administration Medical Center (PVAMC) Hemodialysis Unit from October 2006 through April 2007. Sixty-eight variables regarding demographics, medical history and dialysis treatments were collected on our 34 chronic hemodialysis outpatients. Over a 5-wk interval, 62% (21 of 34) of the chronic hemodialysis patients unexpectedly developed a white precipitate adhering to the lumenal surface of their dialysis blood tubing, with 73 of 580 chronic dialysis treatments exhibiting the phenomenon. Microscopic and biochemical analyses were consistent with white thrombus, formed by an aggregation of platelets and fibrin. An alert was issued and other in-center hemodialysis units noted similar findings. This was remedied by the removal of specific tubing. Both patient-specific and tubing-specific factors may have been operative. Although patient safety was not adversely affected, assessment of clinical and manufacturing variables potentially affecting platelet activation is warranted.
Experimental investigation of nozzle/plume aerodynamics at hypersonic speeds
NASA Technical Reports Server (NTRS)
Bogdanoff, David W.; Cambier, Jean-Luc
1993-01-01
Work continued on the improvement of 16-Inch Shock Tunnel. This comprised studies of ways of improving driver gas ignition, an improved driver gas mixing system, an axial translation system for the driver tube, improved diaphragm materials (carbon steel vs. stainless steel), a copper liner for the part of the driven tube near the nozzle, the use of a buffer gas between the driver and driven gases, the use of N2O in the driven tube, the use of a converging driven tube, operation of the facility as a non-reflected shock tunnel and expansion tube, operation with heated hydrogen or helium driver gas, the use of detonations in the driver and the construction of an enlarged test section. Maintenance and developmental work continued on the scramjet combustor continued. New software which greatly speeds up data analysis has been written and brought on line. In particular, software which provides very rapid generation of model surface heat flux profiles has been brought on line. A considerable amount of theoretical work was performed in connection with upgrading the 16 Inch Shock Tunnel Facility. A one-dimensional Godunov code for very high velocities and any equation of state is intended to add viscous effects in studying the operation of the Shock Tunnel and also of two-stage light gas guns.
CORROSION EXPERIENCE WITH ALUMINUM POWDER PRODUCTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Draley, J.E.; Ruther, W.E.; Greenberg, S.
1963-11-01
Extrusions of aluminum alloy powder products were obtained from several sources and evaluated for corrosion resistance to high-temperature (260-- 350 deg C) water. Several types of tubing impact-extruded by ALCOA were tested. The stronger tabing (M655) failed very rapidly. The weaker tubing suffered extensive localized surface attack and penetration of the corrosion attack along the extrusion direction after prolonged ( approximates 3 months) exposure to 290 deg C water. A precorrosion heat treatment was effective in reducing both types of attack on the weaker tubing. Armour Research Foundation supplied several types of tubing extraded through a bridge die. All tubesmore » failed on prolonged ( approximates 8 months) corrosion in 290 deg C water at the longitudinal bond lines. These lines were formed by the rejoining of the metal streams passing over the mandrel supports in the die during extrusion. Directly extruded tubing supplied by the Torrance Brass Company also failed on extended exposure to 290 deg C water. Many experimental rod extrusions (from Armour Research Foundation and Trefimetaux) exhibited corrosion resistance to static 290 deg C water equivalent to that of wrought alloys. The Trefimetaux specimens were also tested in rapidly flowing water at 315 deg C. Under these conditions a corrosion rate significantly faster than for the wrought alloy was measured. (auth)« less
Vibration analysis of the tympanic membrane with a ventilation tube and a perforation by holography
NASA Astrophysics Data System (ADS)
Maeta, Manabu; Kawakami, Shinichiro; Ogawara, Toshiaki; Masuda, Yu
1991-08-01
For severe otitis media with effusion, insertion of a ventilation tube is performed for the purpose of ventilation of the middle ear cavity and normalization of the eustachian tubular function and middle ear mucosa. The ventilation tube is left in place for as long as several months or even a few years. However, the influence of the indwelling tube on vibration of the tympanic membrane is unknown. Therefore, the authors observed the influence by means of time-averaged holography using human tympanic membranes. The following results were obtained. After insertion of a ventilation tube, vibration pattern of the tympanic membrane was not obviously changed, but the vibration amplitude of the tympanic membrane was decreased, especially at 500 Hz. Generally speaking, the change caused by insertion of a ventilation tube was very small. Also, the vibration pattern of perforated tympanic membrane was not changed, but the vibration amplitude of perforated tympanic membrane was decreased at the low frequency area.
Cut-and-connect of two antiparallel vortex tubes
NASA Technical Reports Server (NTRS)
Melander, Mogens V.; Hussain, Fazle
1988-01-01
Motivated by an early conjecture that vortex cut-and-connect plays a key role in mixing and production of turbulence, helicity and aerodynamic noise, the cross-linking of two antiparallel viscous vortex tubes via direct numerical simulation is studied. The Navier-Stokes equations are solved by a dealiased pseudo-spectral method with 64 cubed grid points in a periodic domain for initial Reynolds numbers Re up to 1000. The vortex tubes are given an initial sinusoidal perturbation to induce a collision and keep the two tubes pressed against each other as annihilation continues. Cross-sectional and wire plots of various properties depict three stages of evolution: (1) Inviscid induction causing vortex cores to first approach and form a contact zone with a dipole cross-section, and then to flatten and stretch; (2) Vorticity annihilation in the contact zone accompanied by bridging between the two vortices at both ends of the contact zone due to a collection of cross-linked vortex lines, now orthogonal to the initial vortex tubes. The direction of dipole advection in the contact zone reverses; and (3) Threading of the remnants of the original vortices in between the bridges as they pull apart. The crucial stage 2 is shown to be a simple consequence of vorticity annihilation in the contact zone, link-up of the un-annihilated parts of vortex lines, and stretching and advection by the vortex tube swirl of the cross-linked lines, which accumulate at stagnation points in front of the annihilating vortex dipole. It is claimed that bridging is the essence of any vorticity cross-linking and that annihilation is sustained by stretching of the dipole by the bridges. Vortex reconnection details are found to be insensitive to asymmetry. Modeling of the reconnection process is briefly examined. The 3D spatial details of scalar transport (at unity Schmidt number), enstrophy production, dissipation and helicity are also examined.
Stability of levothyroxine injection in glass, polyvinyl chloride, and polyolefin containers.
Frenette, Anne Julie; MacLean, Robert D; Williamson, David; Marsolais, Pierre; Donnelly, Ronald F
2011-09-15
The 24-hour stability of a levothyroxine solution admixed and stored in three common infusion containers and infused through polyvinyl chloride (PVC) tubing was evaluated. Levothyroxine sodium 1-μg/mL injection prepared in glass bottles and PVC and polyolefin bags were assayed using high-performance liquid chromatography at 0, 1, 3, 6, 12, and 24 hours; samples drawn directly from the containers, as well as from the distal end of attached PVC tubing, were assayed. The area under the time-versus-concentration curve (AUC) for predicted and delivered doses was calculated; analysis of variance was used for comparison of the percentages of predicted and actual AUC values. The levothyroxine concentration was stable in glass bottles and polyolefin bags through 24 hours (mean ± S.D. percentage of initial concentration remaining, 103.5% ± 2.5% and 100.0% ± 2.9%, respectively). In the PVC infusion bags, the amount of drug decreased to 90% of the initial concentration within 1 hour and then rose and remained within acceptability limits. The levothyroxine concentration of the samples infused through PVC line from glass and polyolefin containers decreased after 1 hour by about 13%; the loss of the drug from the samples infused from PVC bags was higher (18%), presumably due to additive adsorptive effects. In all samples tested, the drug concentration rebounded and remained above 90% to the end of the study. Levothyroxine sodium 1-μg/mL solution was stable for 24 hours in glass bottles and polyolefin bags but when stored in PVC bags, the concentration decreased by 10% after 1 hour.
Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint
Kommineni, P.R.
1983-01-25
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent. 3 figs.
Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint
Kommineni, Prasad R.
1983-01-25
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent.
The Propagation of a Liquid Bolus Through an Elastic Tube and Airway Reopening
NASA Technical Reports Server (NTRS)
Howell, Peter D.; Grotberg, James B.
1996-01-01
We use lubrication theory and matched asymptotic expansions to model the quasi-steady propagation of a liquid bridge through an elastic tube. In the limit of small capillary number, asymptotic expressions are found for the pressure drop across the bridge and the thickness of the liquid film left behind, as functions of the capillary number, the thickness of the liquid lining ahead of the bridge and the elastic characteristics of the tube wall. For a given precursor thickness, we find a critical propagation speed, and hence a critical imposed pressure drop, above which the bridge will eventually burst, and hence the tube will reopen.
Development of a Low Cost High Frequency Pulse Tube Cryocooler
NASA Astrophysics Data System (ADS)
Wang, C.; Caughley, A. J.; Haywood, D. J.
2008-03-01
In cooperation with Industrial Research Ltd (IRL), Cryomech, Inc. is developing a low cost high frequency pulse tube cryocooler. The valveless compressor, developed at IRL, employs two S.S. diaphragms and a novel kinematics driven mechanism. The pulse tube cold head has co-axial configuration. It is separated from the compressor with a SS flexible line of 1 meter long. The test results demonstrate a very small orientation effect of the cold head (<3 K at any orientation). This pulse tube cryocooler provides flexibility for user's integration. It can provide 108W at 77K with an electric input power of 3.7 kW in the primary test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert V. Kolarik II
2002-10-23
A system for the online, non-contact measurement of wall thickness in steel seamless mechanical tubing has been developed and demonstrated at a tubing production line at the Timken Company in Canton, Ohio. The system utilizes laser-generation of ultrasound and laser-detection of time of flight with interferometry, laser-doppler velocimetry and pyrometry, all with fiber coupling. Accuracy (<1% error) and precision (1.5%) are at targeted levels. Cost and energy savings have exceeded estimates. The system has shown good reliability in measuring over 200,000 tubes in its first six months of deployment.
Effects of Convection Electric Fields on Modeled Plasmaspheric Densities and ccc Temperatures
NASA Technical Reports Server (NTRS)
Comfort, Richard H.; Richards, Phil G.; Liao, Jin-Hua; Craven, Paul D.
1998-01-01
This paper examines the effects of convection electric fields on plasmaspheric H+, O+, He+, and N+ densities and electron and ion temperatures. These effects are studied with the aid of the Field Line Interhemispheric Plasma (FLIP) model, which has recently been extended to include the effects of ExB drifts. The FLIP model solves the continuity and momentum equations for the major ion species as well as the energy equations for ions and electrons along entire drifting flux tubes from 100 km altitude in the northern hemisphere to 100 km altitude in the southern hemisphere. Electron heating in the ionosphere and plasmasphere is provided by the solution of two-stream equations for photoelectrons. The dawn-dusk electric field imposed by the solar wind causes changes in plasmaspheric density and temperature as the plasma drifts onto flux tubes having different volumes. In an idealized convection model, outward drifts in the afternoon cause decreases in the plasmasphere density and temperature while inward drifts in the evening cause increases in plasmasphere density and temperature. In this paper we examine the effects of convection electric fields on the rate of refilling of flux tubes and investigate the hypothesis that convection electric fields are responsible for the unusually high evening electron temperatures and the post-midnight density maxima often observed in the winter ionosphere above Millstone Hill.
Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube
NASA Technical Reports Server (NTRS)
Meyer, Scott Andrew
1995-01-01
The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.
Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube
NASA Technical Reports Server (NTRS)
Meyer, Scott Andrew
1995-01-01
The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.
Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube
NASA Technical Reports Server (NTRS)
Meyer, Scott Andrew
1995-01-01
The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.
Low gravity transfer line chilldown
NASA Technical Reports Server (NTRS)
Antar, Basil N.; Collins, Frank G.; Kawaji, Masahiro
1992-01-01
The progress to date is presented in providing predictive capabilities for the transfer line chilldown problem in low gravity environment. A low gravity experimental set up was designed and flown onboard the NASA/KC-135 airplane. Some results of this experimental effort are presented. The cooling liquid for these experiments was liquid nitrogen. The boiling phenomenon was investigated in this case using flow visualization techniques as well as recording wall temperatures. The flow field was established by injecting cold liquid in a heated tube whose temperature was set above saturation values. The tubes were vertically supported with the liquid injected from the lower end of the tube. The results indicate substantial differences in the flow patterns established during boiling between the ground based, (1-g), experiments and the flight experiments, (low-g). These differences in the flow patterns will be discussed and some explanations will be offered.
Fluid Mechanics of Capillary-Elastic Instabilities in Microgravity Environment
NASA Technical Reports Server (NTRS)
Grotberg, James B.
2002-01-01
The aim of this project is to investigate the closure and reopening of lung airways due to surface tension forces, coupled with airway elasticity. Airways are liquid-lined, flexible tubes and closure of airways can occur by a Rayleigh instability of the liquid lining, or an instability of the elastic support for the airway as the surface tension of the air-liquid interface pulls the tube shut, or both. Regardless of the mechanism, the airway is closed because the liquid lining has created a plug that prevents axial gas exchange. In the microgravity environment, surface tension forces dominate lung mechanics and would lead to more prevalent, and more uniformly distributed air-way closure, thereby creating a potential for respiratory problems for astronauts. Once closed the primary option for reopening an airway is by deep inspiration. This maneuver will pull the flexible airways open and force the liquid plug to flow distally by the incoming air stream. Airway reopening depends to a large extent on this plug flow and how it may lead to plug rupture to regain the continuity of gas between the environment and the alveoli. In addition to mathematical modeling of plug flows in liquid-lined, flexible tubes, this work has involved benchtop studies of propagating liquid plugs down tube networks that mimic the human airway tree. We have extended the work to involve animal models of liquid plug propagation in rat lungs. The liquid is radio-opaque and x-ray video imaging is used to ascertain the movement and distribution of the liquid plugs so that comparisons to theory may be made. This research has other uses, such as the delivery of liquids or drugs into the lung that may be used for surfactant replacement therapy or for liquid ventilation.
Effect of Body Mass Index on Postoperative Transfusions and 24-Hour Chest-Tube Output
Nolan, Heather R.; Ramaiah, Chandrashekhar
2011-01-01
An increasing obese population in the United States focuses attention on the effect of obesity on surgical outcomes. Our objective was to see if obesity, determined by body mass index (BMI), contributed to bleeding in coronary artery bypass graft (CABG) surgery as measured by intraoperative and postoperative packed red blood cell transfusion frequency and amount and 24-hour chest-tube output. A retrospective chart review examined 150 subjects undergoing single-surgeon off-pump or on-pump CABG surgery between September 2006 and April 2009. BMI groups included normal-weight (BMI <25), overweight (BMI 25 to 29), and obese (BMI ≥30). Analyses used a chi-square test to determine variances in number of transfusions, and ANOVA for transfusion amount and 24-hour chest-tube amount. The percentage of subjects receiving intraoperative transfusions varied significantly by BMI group (p = 0.022). The percentage of subjects receiving transfusions in the 72-hour postoperative period showed a decreasing linear trend based on BMI group (p = 0.054). The percentage of subjects receiving transfusions in the combined intraoperative or 72-hour postoperative period showed a decreasing linear trend based on BMI group (p = 0.054). The transfusion amount during the 72-hour postoperative period varied significantly between BMI groups (p = 0.021), and the test for a linear decrease across groups was significant (p = 0.020). Twenty-four hour chest-tube output showed variation across all three BMI categories (p = 0.018) with chest-tube output decreasing with increasing obesity in a linear fashion (p = 0.006). Transfusion rate and amount indicate total blood loss is decreased in the obese, and chest-tube output findings give a direct measurable indicator of blood loss from the surgical site indicating increasing BMI is linearly correlated with decreasing postoperative bleeding. PMID:22654469
Device and method for shortening reactor process tubes
Frantz, Charles E.; Alexander, William K.; Lander, Walter E. B.
1980-01-01
This disclosure describes a device and method for in situ shortening of nuclear reactor zirconium alloy process tubes which have grown as a result of radiation exposure. An upsetting technique is utilized which involves inductively heating a short band of a process tube with simultaneous application of an axial load sufficient to cause upsetting with an attendant decrease in length of the process tube.
Rotary roller of no. 2 seamless line in bays 19 ...
Rotary roller of no. 2 seamless line in bays 19 and 20 of the main pipe mill building looking north. - U.S. Steel National Tube Works, Main Pipe Mill Building, Along Monongahela River, McKeesport, Allegheny County, PA
Rotary roller mandrel of no. 2 seamless line in bays ...
Rotary roller mandrel of no. 2 seamless line in bays 19 and 20 of the main pipe mill building looking south. - U.S. Steel National Tube Works, Main Pipe Mill Building, Along Monongahela River, McKeesport, Allegheny County, PA
Taylorwilson four roll straightener of the no. 1 seamless line ...
Taylor-wilson four roll straightener of the no. 1 seamless line in bay 12 of the main pipe mill building. - U.S. Steel National Tube Works, Main Pipe Mill Building, Along Monongahela River, McKeesport, Allegheny County, PA
Luís, Ana L; Rodrigues, Jorge M; Geuna, Stefano; Amado, Sandra; Shirosaki, Yuki; Lee, Jennifer M; Fregnan, Federica; Lopes, Maria A; Veloso, Antonio P; Ferreira, Antonio J; Santos, Jose D; Armada-Da-silva, Paulo A S; Varejão, Artur S P; Maurício, Ana Colette
2008-06-01
Poly(lactic-co-glycolic acid) (PLGA) nerve tube guides, made of a novel proportion (90:10) of the two polymers, poly(L-lactide): poly(glycolide) and covered with a neural cell line differentiated in vitro, were tested in vivo for promoting nerve regeneration across a 10-mm gap of the rat sciatic nerve. Before in vivo testing, the PLGA 90:10 tubes were tested in vitro for water uptake and mass loss and compared with collagen sheets. The water uptake of the PLGA tubes was lower, and the mass loss was more rapid and higher than those of the collagen sheets when immersed in phosphate-buffered saline (PBS) solution. The pH values of immersing PBS did not change after soaking the collagen sheets and showed to be around 7.4. On the other hand, the pH values of PBS after soaking PLGA tubes decreased gradually during 10 days reaching values around 3.5. For the in vivo testing, 22 Sasco Sprague adult rats were divided into four groups--group 1: gap not reconstructed; group 2: gap reconstructed using an autologous nerve graft; group 3: gap reconstructed with PLGA 90:10 tube guides; group 4: gap reconstructed with PLGA 90:10 tube guides covered with neural cells differentiated in vitro. Motor and sensory functional recovery was evaluated throughout a healing period of 20 weeks using sciatic functional index, static sciatic index, extensor postural thrust, withdrawal reflex latency, and ankle kinematics. Stereological analysis was carried out on regenerated nerve fibers. Both motor and sensory functions improved significantly in the three experimental nerve repair groups, although the rate and extent of recovery was significantly higher in the group where the gap was reconstructed using the autologous graft. The presence of neural cells covering the inside of the PLGA tube guides did not make any difference in the functional recovery. By contrast, morphometric analysis showed that the introduction of N1E-115 cells inside PLGA 90:10 tube guides led to a significant lower number and size of regenerated nerve fibers, suggesting thus that this approach is not adequate for promoting peripheral nerve repair. Further studies are warranted to assess the role of other cellular systems as a foreseeable therapeutic strategy in peripheral nerve regeneration.
Propagation of atmospheric-pressure ionization waves along the tapered tube
NASA Astrophysics Data System (ADS)
Xia, Yang; Wang, Wenchun; Liu, Dongping; Yan, Wen; Bi, Zhenhua; Ji, Longfei; Niu, Jinhai; Zhao, Yao
2018-02-01
Gas discharge in a small radius dielectric tube may result in atmospheric pressure plasma jets with high energy and density of electrons. In this study, the atmospheric pressure ionization waves (IWs) were generated inside a tapered tube. The propagation behaviors of IWs inside the tube were studied by using a spatially and temporally resolved optical detection system. Our measurements show that both the intensity and velocity of the IWs decrease dramatically when they propagate to the tapered region. After the taper, the velocity, intensity, and electron density of the IWs are improved with the tube inner diameter decreasing from 4.0 to 0.5 mm. Our analysis indicates that the local gas conductivity and surface charges may play a role in the propagation of the IWs under such a geometrical constraint, and the difference in the dynamics of the IWs after the taper can be related to the restriction in the size of IWs.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-26
... duty order on seamless carbon and alloy steel standard, line, and pressure pipe from the People's... the antidumping duty order on seamless carbon and alloy steel standard, line, and pressure pipe from... Making Co., Ltd.; Wuxi Seamless Special Pipe Co., Ltd.; Wuxi Sifang Steel Tube Co., Ltd.; Wuxi Zhenda...
Code of Federal Regulations, 2010 CFR
2010-10-01
... the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be of the... as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank... copper tubing or a short length of flexible hose must be installed in the fuel supply line at or near the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
..., expanded end, crimped end, threaded), coating (e.g., plastic, paint), insulation, attachments (e.g., plain... ``line sets'' of seamless refined copper tubes (with or without fittings or insulation) suitable for connecting an outdoor air conditioner or heat pump to an indoor evaporator unit. The phrase ``all sets of...
Superconducting Technology Assessment
2005-08-01
designing a single compressor pulse tube between the high pump frequency which produces good efficiency at the higher...noise models must be extended to sub-micron JJs. Transmission line models must be extended to the high frequency regime. VHDL models and methods ...temperatures and the low frequencies needed at low temperatures. Hybrid Sterling- pulse tube coolers allow the higher efficiency of a Sterling high
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-12
... providing video description for educational program content delivered via the Internet (e.g., YouTube, YouTube EDU, Second Life, and virtual on-line courses) or through technological devices (e.g., smart.... Box 22207, Alexandria, VA 22304. Telephone, toll free: 1-877-433-7827. FAX: (703) 605-6794. If you use...
Automated Chromium Plating Line for Gun Barrels
1979-09-01
consistent pretreatments and bath dwell times. Some of the advantages of automated processing include increased productivity (average of 20^) due to...when automated processing procedures’ are used. The current method of applying chromium electrodeposits to gun tubes is a manual, batch operation...currently practiced with rotary swaged gun tubes would substantially reduce the difficulties in automated processing . RECOMMENDATIONS
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-26
... end, expanded end, crimped end, threaded), coating (e.g., plastic, paint), insulation, attachments (e... products, including ``line sets'' of seamless refined copper tubes (with or without fittings or insulation) suitable for connecting an outdoor air conditioner or heat pump to an indoor evaporator unit. The phrase...
Chronic stress effects and their reversibility on the Fallopian tubes and uterus in rats.
Divyashree, S; Yajurvedi, H N
2018-01-01
The durational effects of chronic stress on the Fallopian tubes and uterus were studied by exposing rats to stressors in the form of restraint (1h) and forced swimming (15min) daily for 4, 8 or 12 weeks. One group of stressed rats from each time period was then maintained without exposure to stressors for a further 4 weeks to assess their ability to recover from stress. All time periods of stress exposure resulted in decreased weight of the body and Fallopian tubes; however, the relative weight of the uterus and serum concentrations of oestradiol and insulin increased significantly. The antioxidant potential was decreased with increased malondialdehyde concentrations in the Fallopian tubes following all durations of exposure and after 4 and 8 weeks of stress exposure in the uterus. Interestingly, rats stressed for 12 weeks showed an increase in serum testosterone concentration and antioxidant enzyme activities with a decrease in malondialdehyde concentration in the uterus. The antioxidant enzyme activities and malondialdehyde concentration in the Fallopian tubes of all recovery group rats were similar to stressed rats. However, in the uterus these parameters were similar to controls in recovery group rats after 4 weeks or 8 weeks of exposure, but after 12 weeks of stress exposure these parameters did not return to control levels following the recovery period. These results reveal, for the first time, that chronic stress elicits an irreversible decrease in antioxidant defence in the Fallopian tubes irrespective of exposure duration, whereas the uterus develops reversible oxidative stress under short-term exposure but increased antioxidant potential with endometrial proliferation following long-term exposure.
NASA Technical Reports Server (NTRS)
Suess, Steven T.; Wang, A. H.; Wu, Shi T.; Nerney, S.
1998-01-01
Evaporation is the consequence of slow plasma heating near the tops of streamers where the plasma is only weakly contained by the magnetic field. The form it takes is the slow opening of field lines at the top of the streamer and transient formation of new solar wind. It was discovered in polytropic model calculations, where due to the absence of other energy loss mechanisms in magnetostatic streamers, its ultimate endpoint is the complete evaporation of the streamer. This takes, for plausible heating rates, weeks to months in these models. Of course streamers do not behave this way, for more than one reason. One is that there are losses due to thermal conduction to the base of the streamer and radiation from the transition region. Another is that streamer heating must have a characteristic time constant and depend on the ambient physical conditions. We use our global Magnetohydrodynamics (MHD) model with thermal conduction to examine a few examples of the effect of changing the heating scale height and of making ad hoc choices for how the heating depends on ambient conditions. At the same time, we apply and extend the analytic model of streamers, which showed that streamers will be unable to contain plasma for temperatures near the cusp greater than about 2xl0(exp 6) K. Slow solar wind is observed to come from streamers through transient releases. A scenario for this that is consistent with the above physical process is that heating increases the near-cusp temperature until field lines there are forced open. The subsequent evacuation of the flux tubes by the newly forming slow wind decreases the temperature and heating until the flux tubes are able to reclose. Then, over a longer time scale, heating begins to again refill the flux tubes with plasma and increase the temperature until the cycle repeats itself. The calculations we report here are first steps towards quantitative evaluation of this scenario.
[A project to reduce the incidence of intubation care errors among foreign health aides].
Chen, Mei-Ju; Lu, Yu-Hua; Chen, Chiu-Chun; Li, Ai-Cheng
2014-08-01
Foreign health aides are the main providers of care for the elderly and the physically disabled in Taiwan. Correct care skills improve patient safety. In 2010, the incidence of mistakes among foreign health aides in our hospital unit was 58% for nasogastric tube care and 57% for tracheostomy tube care. A survey of foreign health aides and nurses in the unit identified the main causes of these mistakes as: communication difficulties, inaccurate instructions given to patients, and a lack of standard operating procedures given to the foreign health aides. This project was designed to reduce the rates of improper nasogastric tube care and improper tracheostomy tube care to 20%, respectively. This project implemented several appropriate measures. We produced patient instruction hand-outs in Bahasa Indonesia, established a dedicated file holder for Bahasa Indonesian tube care reference information, produced Bahasa Indonesian tube-care-related posters, produced a short film about tube care in Bahasa Indonesian, and established a standardized operating procedure for tube care in our unit. Between December 15th and 31st, 2011, we audited the performance of a total of 32 foreign health aides for proper execution of nasogastric tube care (21 aides) and of proper execution of tracheostomy tube care (11 aides). Patients with concurrent nasogastric and tracheostomy tubes were inspected separately for each care group. The incidence of improper care decreased from 58% to 18% nasogastric intubation and 57% to 18% for tracheostomy intubation. This project decreased significantly the incidence of improper tube care by the foreign health aides in our unit. Furthermore, the foreign health aides improved their tube nursing care skills. Therefore, this project improved the quality of patient care.
Mitate, Eiji; Kubota, Kensuke; Ueki, Kenji; Inoue, Rumi; Inoue, Ryosuke; Momii, Kenta; Sugimori, Hiroshi; Maehara, Yoshihiko; Nakamura, Seiji
2015-01-01
Communication is a serious problem for patients with ventilator-dependent tetraplegia. A 73-year-old man was presented at the emergency room in cardiopulmonary arrest after falling from a height of 2 m. After successful resuscitation, fractures of the cervical spine and cervical spinal cord injury were found. Due to paralysis of the respiratory muscles, a mechanical ventilator with a tracheostomy tube was required. First, a cuffed tracheostomy tube and a speaking tracheostomy tube were inserted, and humidified oxygen was introduced via the suction line. Using these tubes, the patient could produce speech sounds, but use was limited to 10 min due to discomfort. Second, a mouthstick stylus, fixed on a mouthpiece that fits over the maxillary teeth, was used. The patient used both a communication board and a touch screen device with this mouthstick stylus. The speaking tracheostomy tube and mouthstick stylus greatly improved his ability to communicate.
Priddy, Tommy G.
1988-01-01
An inflatable wing is formed from a pair of tapered, conical inflatable tubes in bonded tangential contact with each other. The tubes are further connected together by means of top and bottom reinforcement boards having corresponding longitudinal edges lying in the same central diametral plane passing through the associated tube. The reinforcement boards are made of a stiff reinforcement material, such as Kevlar, collapsible in a direction parallel to the spanwise wing axis upon deflation of the tubes. The stiff reinforcement material cooperates with the inflated tubes to impart structural I-beam characteristics to the composite structure for transferring inflation pressure-induced tensile stress from the tubes to the reinforcement boards. A plurality of rigid hoops shaped to provide airfoil definition are spaced from each other along the spanwise axis and are connected to the top and bottom reinforcement boards. Tension lines are employed for stabilizing the hoops along the trailing and leading edges thereof.
Russell, Harold C.
1979-01-01
This disclosure describes a device for repeatably scribing a V-shaped scratch having sharply defined dimensions on the interior surface of a nuclear reactor fuel rod tube. A cutting tool having a V-shaped cutting tip is supported within the fuel rod tube so that the V-shaped cutting tip can be pivoted about an axis and scribe a scratch on the interior surface of the fuel rod tube. Lengthwise the scratch runs parallel to a line drawn through the axis of the fuel rod tube and is in the shape of an arc, and widthwise the scratch is V-shaped. This shape is used because the dimensions of the scratch can be plugged into appropriate formulas to calculate stress intensity of cracks in fuel rod tubes. Since the fuel rod tubes which are to be scribed may be radioactive, the scratching assembly is designed for use in a fixture which allows it to be operated in a cave by remote control handling devices.
High power linear pulsed beam annealer
Strathman, Michael D.; Sadana, Devendra K.; True, Richard B.
1983-01-01
A high power pulsed electron beam is produced in a system comprised of an electron gun having a heated cathode, control grid, focus ring, and a curved drift tube. The drift tube is maintained at a high positive voltage with respect to the cathode to accelerate electrons passing through the focus ring and to thereby eliminate space charge. A coil surrounding the curved drift tube provides a magnetic field which maintains the electron beam focused about the axis of the tube and imparts motion on electrons in a spiral path for shallow penetration of the electrons into a target. The curvature of the tube is selected so there is no line of sight between the cathode and a target holder positioned within a second drift tube spaced coaxially from the curved tube. The second tube and the target holder are maintained at a reference voltage that decelerates the electrons. A second coil surrounding the second drift tube maintains the electron beam focused about the axis of the second drift tube and compresses the electron beam to the area of the target. The target holder can be adjusted to position the target where the cross section of the beam matches the area of the target.
The influence of focal spot blooming on high-contrast spatial resolution in CT imaging.
Grimes, Joshua; Duan, Xinhui; Yu, Lifeng; Halaweish, Ahmed F; Haag, Nicole; Leng, Shuai; McCollough, Cynthia
2015-10-01
The objective of this work was to investigate focal spot blooming effects on the spatial resolution of CT images and to evaluate an x-ray tube that uses dynamic focal spot control for minimizing focal spot blooming. The influence of increasing tube current at a fixed tube potential of 80 kV on high-contrast spatial resolution of seven different CT scanner models (scanners A-G), including one scanner that uses dynamic focal spot control to reduce focal spot blooming (scanner A), was evaluated. Spatial resolution was assessed using a wire phantom for the modulation transfer function (MTF) calculation and a copper disc phantom for measuring the slice sensitivity profile (SSP). The impact of varying the tube potential was investigated on two scanner models (scanners A and B) by measuring the MTF and SSP and also by using the resolution bar pattern module of the ACR CT phantom. The phantoms were scanned at 70-150 kV on scanner A and 80-140 kV on scanner B, with tube currents from 100 mA up to the maximum tube current available on each scanner. The images were reconstructed using a slice thickness of 0.6 mm with both smooth and sharp kernels. Additionally, focal spot size at varying tube potentials and currents was directly measured using pinhole and slit camera techniques. Evaluation of the MTF and SSP data from the 7 CT scanner models evaluated demonstrated decreased focal spot blooming for newer scanners, as evidenced by decreasing deviations in MTF and SSP as tube current varied. For scanners A and B, where focal spot blooming effects as a function of tube potential were assessed, the spatial resolution variation in the axial plane was much smaller on scanner A compared to scanner B as tube potential and current changed. On scanner A, the 50% MTF never decreased by more than 2% from the 50% MTF measured at 100 mA. On scanner B, the 50% MTF decreased by as much as 19% from the 50% MTF measured at 100 mA. Assessments of the SSP, the bar patterns in the ACR phantom and the pinhole and slit camera measurements were consistent with the MTF calculations. Focal spot blooming has a noticeable effect on spatial resolution in CT imaging. The focal spot shaping technology of scanner A greatly reduced blooming effects.
A position- and time-sensitive photon-counting detector with delay- line read-out
NASA Astrophysics Data System (ADS)
Jagutzki, Ottmar; Dangendorf, Volker; Lauck, Ronald; Czasch, Achim; Milnes, James
2007-05-01
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy.
Development of the Miniature Pulse Tube Cryocooler
NASA Astrophysics Data System (ADS)
Matsumoto, N.; Yasukawa, Y.; Ohshima, K.; Toyama, K.; Tsukahara, Y.; Kamoshita, T.; Takeuchi, T.
2004-06-01
Fuji Electric has developed a pulse tube cryocooler (PTC) with in-line configuration with a cooling capacity of 3 W at 70 K and requiring 100 W of electrical input power. The emphasis has been on compactness, lightweight, high performance and low cost. In particular, the dimensions of the PTC have been reduced to a width of 190 mm and a height of 300 mm. Presently, we are developing a U-shaped PTC based on the technology of the in-line PTC. The advantage of the U-shaped PTC is that the cold head is located at the end for easy accessing. The key issue for developing the U-shaped PTC is the design of the flow straightener at the cold head. As a first step in the development we visualized the inside of the pulse tube by using particle image velocimetry (PIV). The design of the flow straightener is based on the visualization results. Preliminary tests indicated that the cooling performance of the U-shaped PTC is 2 W at 70 K while requiring 51 W PV power. We will present the test results on the U-shaped PTC as well as the in-line PTC.
NASA Technical Reports Server (NTRS)
Robertson, Glen A. (Inventor)
1993-01-01
A fluid separator for separating particulate matter such as contaminates is provided which includes a series of spiral tubes of progressively decreasing cross sectional area connected in series. Each tube has an outlet on the outer curvature of the spiral. As fluid spirals down a tube, centrifugal force acts to force the heavier particulate matter to the outer wall of the tube, where it exits through the outlet. The remaining, and now cleaner, fluid reaches the next tube, which is smaller in cross sectional area, where the process is repeated. The fluid which comes out the final tube is diminished of particulate matter.
Determination of Material Properties Near the Glass Transition Temperature for an Isogrid Boom
NASA Technical Reports Server (NTRS)
Blandino, Joseph R.; Woods-Vedeler, Jessica A. (Technical Monitor)
2002-01-01
Experiments were performed and results obtained to determine the temperature dependence of the modulus of elasticity for a thermoplastic isogrid tube. The isogrid tube was subjected to axial tensile loads of 0-100 lbf and strain was measured at room and elevated temperatures of 100, 120, 140, 160, 180, 190, and 200 F. These were based on tube manufacturer specifying an incorrect glass transition temperature of 210 F. Two protocols were used. For the first protocol the tube was brought to temperature and a tensile test performed. The tube was allowed to cool between tests. For the second protocol the tube was ramped to the desired test temperature and held. A tensile test was performed and the tube temperature ramped to the next test temperature. The second protocol spanned the entire test range. The strain rate was constant at 0.008 in/min. Room temperature tests resulted in the determination of an average modulus of 2.34 x 106 Psi. The modulus decreased above 100 F. At 140 F the modulus had decreased by 7.26%. The two test protocols showed good agreement below 160 F. At this point the glass transition temperature had been exceeded. The two protocols were not repeated because the tube failed.
Pulse tube cryocoolers for industrial applications
NASA Astrophysics Data System (ADS)
Martin, J. L.; Martin, C. M.
2002-05-01
Stirling-type, high frequency pulse tube cryocoolers have received considerable interest in the past decade due to their high reliability, low vibration, and high efficiency. Most of the previous development of Stirling-type pulse tube cryocoolers has focused on relatively small machines with cooling powers in the range of 5 W at 80 K. In this paper, we discuss the extension of Stirling-type pulse tube cryocoolers to higher capacities for industrial applications. Mesoscopic Devices is currently developing a family of pulse tube cryocoolers with capacities ranging from 10 W at 80 K to over 1300 W at 80 K. Each of these machines uses a 50 or 60 Hz moving magnet linear compressor, inertance tube phase shift network, and either in-line or coaxial pulse tube expanders. With input powers of up to 20 kW, these large cryocoolers require different heat exchanger and regenerator designs to efficiently exchange heat with the load and environment. Design and construction techniques for the expander and heat exchangers are discussed.
Patel, Shreya; Lalwani, Kirk; Koh, Jeffrey; Wu, Lei; Fu, Rongwei
2014-06-01
Uncuffed endotracheal tubes are still preferred over cuffed tubes in certain situations in pediatric anesthesia. Inaccurately sized uncuffed endotracheal tubes may lead to inadequate ventilation or tracheal mucosal damage during anesthesia. Endotracheal tube size in children is usually assessed by measuring the audible leak pressure; if the fit of the tube and the leak pressure decrease significantly with time, reintubation during surgery as a result of inability to ventilate effectively may be challenging, and could lead to patient morbidity. There is no evidence to indicate whether leak pressure increases or decreases with time following endotracheal intubation with uncuffed tubes in children. We measured leak pressure for 30 min following tracheal intubation in 46 ASA I children age 0-7 years after excluding factors known to modify leak pressure. The largest mean change in leak pressure occurred between time points 0 and 15 min, an increase of 3.5 cmH2O. Endotracheal tube size and type of procedure were associated with the leak pressure. In the final linear mixed model, there were no statistically significant variations in leak pressure over time (P = 0.129) in this group of children. We did not identify a consistent change in leak pressure within 30 min following tracheal intubation with uncuffed endotracheal tubes in this group of children.
Microfluidic platform for optimization of crystallization conditions
NASA Astrophysics Data System (ADS)
Zhang, Shuheng; Gerard, Charline J. J.; Ikni, Aziza; Ferry, Gilles; Vuillard, Laurent M.; Boutin, Jean A.; Ferte, Nathalie; Grossier, Romain; Candoni, Nadine; Veesler, Stéphane
2017-08-01
We describe a universal, high-throughput droplet-based microfluidic platform for crystallization. It is suitable for a multitude of applications, due to its flexibility, ease of use, compatibility with all solvents and low cost. The platform offers four modular functions: droplet formation, on-line characterization, incubation and observation. We use it to generate droplet arrays with a concentration gradient in continuous long tubing, without using surfactant. We control droplet properties (size, frequency and spacing) in long tubing by using hydrodynamic empirical relations. We measure droplet chemical composition using both an off-line and a real-time on-line method. Applying this platform to a complicated chemical environment, membrane proteins, we successfully handle crystallization, suggesting that the platform is likely to perform well in other circumstances. We validate the platform for fine-gradient screening and optimization of crystallization conditions. Additional on-line detection methods may well be integrated into this platform in the future, for instance, an on-line diffraction technique. We believe this method could find applications in fields such as fluid interaction engineering, live cell study and enzyme kinetics.
Experimental and numerical investigations on melamine wedges.
Schneider, S
2008-09-01
Melamine wedges are often used as acoustic lining material for anechoic chambers. It was proposed here to study the effects of the mounting conditions on the acoustic properties of the melamine wedges used in the large anechoic chamber at the LMA. The results of the impedance tube measurements carried out show that the mounting conditions must be taken into account when assessing the quality of an acoustic lining. As it can be difficult to simulate these mounting conditions in impedance tube experiments, a numerical method was developed, which can be used to complete the experiments or for parametric studies. By combining the finite and the boundary element method, it is possible to investigate acoustic linings with almost no restrictions as to the geometry, material behavior, or mounting conditions. The numerical method presented here was used to study the acoustic properties of the acoustic lining installed in the anechoic chamber at the LMA. Further experiments showed that the behavior of the melamine foam is anisotropic. Numerical simulations showed that this anisotropy can be used to advantage when designing an acoustic lining.
Development of an engineering model traveling wave tube amplifier for space communication systems
NASA Technical Reports Server (NTRS)
Eallonardo, C. M.; Songli, J.; Basiulis, A.
1972-01-01
A design has been made of a 100 watt traveling-wave tube amplifier for use in space communication applications. The features of very high overall efficiency and heat rejection of waste heat at low thermal densities were predominant in the design concept. The design concept was proven by building a series of tubes, operating at efficiencies up to 50%. These tubes utilized heat pipe cooling and heat distribution such that 150 watts of waste heat was rejected at a density of less than 1.5 watts per square inch. A power supply to convert a 28 volt primary line of the needs of the TWT was built and operated at 85% efficiency.
Estimating probable flaw distributions in PWR steam generator tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorman, J.A.; Turner, A.P.L.
1997-02-01
This paper describes methods for estimating the number and size distributions of flaws of various types in PWR steam generator tubes. These estimates are needed when calculating the probable primary to secondary leakage through steam generator tubes under postulated accidents such as severe core accidents and steam line breaks. The paper describes methods for two types of predictions: (1) the numbers of tubes with detectable flaws of various types as a function of time, and (2) the distributions in size of these flaws. Results are provided for hypothetical severely affected, moderately affected and lightly affected units. Discussion is provided regardingmore » uncertainties and assumptions in the data and analyses.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... countervailing duty order on seamless carbon and alloy steel standard, line, and pressure pipe from the People's... administrative review of the countervailing duty order on seamless carbon and alloy steel standard, line, and... Making Co., Ltd., Wuxi Seamless Special Pipe Co., Ltd., Wuxi Sifang Steel Tube Co., Ltd., Wuxi Zhenda...
The Effects of a History-Based Instructional Material on the Students' Understanding of Field Lines
ERIC Educational Resources Information Center
Pocovi, M. Cecilia
2007-01-01
Many students in physics courses fail to achieve a desired conceptual change because they assign an incorrect ontology to the to-be-learned concept. This situation has been detected in previous research for the case of field lines: many college students assign material properties to the lines and describe them, for example, as tubes that contain…
Fin-and-tube heat exchanger material and inlet velocity effect under frosting conditions
NASA Astrophysics Data System (ADS)
Keryakos, Elie; Toubassy, Joseph; Danlos, Amélie; Clodic, Denis; Descombes, Georges
2017-02-01
The frosting fin-and-tube heat exchanger used in this study is implemented in the dehydration process of a biogas upgrading pilot. Water is separated from the biogas by frosting it at very low temperatures on the cold surfaces of the fin-and-tube heat exchanger. Once frosted, a defrosting system is used to remove water from the process. The main interest of this study is the frosting system. The effects of the biogas velocity, fin material, tube material and frost layer thickness on the performance of the fin-and-tube heat exchanger are investigated. Increasing the biogas velocity tends to increase the frosting layer thickness and the external pressure drop. This will lead to decrease the heat exchanger performance and the frosting cycle duration. The thermal conductivity of the fins and tubes has a major effect on the performance of the heat exchanger. Higher thermal conductivity decreases the heat exchanged surface. A numerical model has been developed, then numerical and experimental results extracted from a biogas upgrading pilot are compared.
Weld joint concepts for on-orbit repair of Space Station Freedom fluid system tube assemblies
NASA Technical Reports Server (NTRS)
Jolly, Steven D.
1993-01-01
Because Space Station Freedom (SSF) is an independent satellite, not depending upon another spacecraft for power, attitude control, or thermal regulation, it has a variety of tubular, fluid-carrying assemblies on-board. The systems of interest in this analysis provide breathing air (oxygen and nitrogen), a working fluid (two-phase anhydrous ammonia) for thermal control, and a monopropellant (hydrazine) for station reboost. The tube assemblies run both internally and externally with respect to the habitats. They are found in up to 50 ft. continuous lengths constructed of mostly AISI 316L stainless steel tubing, but also including some Inconel 625 nickel-iron and Monel 400 nickel-copper alloy tubing. The outer diameters (OD) of the tubes range from 0.25-1.25 inches, and the wall thickness between 0.028-.095 inches. The system operational pressures range from 377 psi (for the thermal control system) to 3400 psi (for the high pressure oxygen and nitrogen supply lines in the ECLSS). SSF is designed for a fifteen to thirty year mission. It is likely that the tubular assemblies (TA's) will sustain damage or fail during this lifetime such that they require repair or replacement. The nature of the damage will be combinations of punctures, chips, scratches, and creases and may be cosmetic or actually leaking. The causes of these hypothetical problems are postulated to be: (1) faulty or fatigued fluid joints--both QD's and butt-welds; (2) micro-meteoroid impacts; (3) collison with another man-made object; and (4) over-pressure strain or burst (system origin). While the current NASA baseline may be to temporarily patch the lines by clamping metal c-sections over the defect, and then perform high pressure injection of a sealing compound, it is clear that permanent repair of the line(s) is necessary. This permanent repair could be to replace the entire TA in the segment, or perhaps the segment itself, both alternatives being extremely expensive and risky. The former would likely require extensive EVA to release TA clamps and pose great risk to other engineering subsystems, and the latter would require major de-servicing of the Station.
On-line measurement of diameter of hot-rolled steel tube
NASA Astrophysics Data System (ADS)
Zhu, Xueliang; Zhao, Huiying; Tian, Ailing; Li, Bin
2015-02-01
In order to design a online diameter measurement system for Hot-rolled seamless steel tube production line. On one hand, it can play a stimulate part in the domestic pipe measuring technique. On the other hand, it can also make our domestic hot rolled seamless steel tube enterprises gain a strong product competitiveness with low input. Through the analysis of various detection methods and techniques contrast, this paper choose a CCD camera-based online caliper system design. The system mainly includes the hardware measurement portion and the image processing section, combining with software control technology and image processing technology, which can complete online measurement of heat tube diameter. Taking into account the complexity of the actual job site situation, it can choose a relatively simple and reasonable layout. The image processing section mainly to solve the camera calibration and the application of a function in Matlab, to achieve the diameter size display directly through the algorithm to calculate the image. I build a simulation platform in the design last phase, successfully, collect images for processing, to prove the feasibility and rationality of the design and make error in less than 2%. The design successfully using photoelectric detection technology to solve real work problems
NASA Technical Reports Server (NTRS)
Luna, M.; Diaz, A. J.; Oliver, R.; Terradas, J.; Karpen, J.
2016-01-01
Solar prominences are subject to both field-aligned (longitudinal) and transverse oscillatory motions, as evidenced by an increasing number of observations. Large-amplitude longitudinal motions provide valuable information on the geometry of the filament channel magnetic structure that supports the cool prominence plasma against gravity. Our pendulum model, in which the restoring force is the gravity projected along the dipped field lines of the magnetic structure, best explains these oscillations. However, several factors can influence the longitudinal oscillations, potentially invalidating the pendulum model. Aims. The aim of this work is to study the influence of large-scale variations in the magnetic field strength along the field lines, i.e., variations of the cross-sectional area along the flux tubes supporting prominence threads. Methods. We studied the normal modes of several flux tube configurations, using linear perturbation analysis, to assess the influence of different geometrical parameters on the oscillation properties. Results. We found that the influence of the symmetric and asymmetric expansion factors on longitudinal oscillations is small.Conclusions. We conclude that the longitudinal oscillations are not significantly influenced by variations of the cross-section of the flux tubes, validating the pendulum model in this context.
Why do aged fluorescent tubes flicker?
NASA Astrophysics Data System (ADS)
Plihon, Nicolas; Ferrand, Jérémy; Guyomar, Tristan; Museur, Flavien; Taberlet, Nicolas
2017-11-01
Our everyday experience of aged and defective fluorescent tubes or bulbs informs us that they may flicker and emit a clicking sound while struggling to light up. In this article, the physical mechanisms controlling the initial illumination of a functioning fluorescent tube are investigated using a simple and affordable experimental setup. Thermionic emission from the electrodes of the tube controls the startup of fluorescent tubes. The origin of the faulty startup of aged fluorescent tubes is discussed and flickering regimes using functional tubes are artificially produced using a dedicated setup that decreases electron emission by the thermionic effect in a controlled manner. The physical parameters controlling the occurrence of flickering light are discussed, and their temporal statistics are reported.
Passive Fuel Tank Inerting Systems for Ground Combat Vehicles
1988-09-01
elastomers and sealants used in currently fielded equipment and redesign of selected hydraulic and gun recoil systems would be necessary to...constraint~s or access problems. "* Fuel Lines.- Fuel lines are routed to use the least amount of line possible. Fuel lines are high-pressure braided ...steel and rubber hose or steel tube construction. "* Fuel Pumps. Fuel pumps are usually mounted internal to the fuel tanks, are of heavy-duty commercial
Method Of Making Closed End Ceramic Fuel Cell Tubes
Borglum, Brian P.
2002-04-30
A method of manufacturing closed end ceramic fuel cell tubes with improved properties and higher manufacturing yield is disclosed. The method involves bonding an unfired cap to a hollow unfired tube to form a compound joint. The assembly is then fired to net shape without subsequent machining. The resultant closed end tube is superior in that it provides a leak-tight seal and its porosity is substantially identical to that of the tube wall. The higher manufacturing yield associated with the present method decreases overall fuel cell cost significantly.
Maize pollen coat xylanase facilitates pollen tube penetration into silk during sexual reproduction.
Suen, Der Fen; Huang, Anthony H C
2007-01-05
Cell wall hydrolases are well documented to be present on pollen, but their roles on the stigma during sexual reproduction have not been previously demonstrated. We explored the function of the tapetum-synthesized xylanase, ZmXYN1, on maize (Zea mays L.) pollen. Transgenic lines (xyl-less) containing little or no xylanase in the pollen coat were generated with use of an antisense construct of the xylanase gene-coding region driven by the XYN1 gene promoter. Xyl-less and wild-type plants had similar vegetative growth. Electron microscopy revealed no appreciable morphological difference in anther cells and pollen between xyl-less lines and the wild type, whereas immunofluorescence microscopy and biochemical analyses indicated an absence of xylanase on xyl-less pollen. Xyl-less pollen germinated as efficiently as wild-type pollen in vitro in a liquid medium but less so on gel media of increasing solidity or on silk, which is indicative of partial impaired water uptake. Once germinated in vitro or on silk, the xyl-less and wild-type pollen tubes elongated at comparable rates. Tubes of germinated xyl-less pollen on silk did not penetrate into the silk as efficiently as tubes of wild-type pollen, and this lower efficiency could be overcome by the addition of xylanase to the silk. For wild-type pollen, coat xylanase activity on oat spelled xylan in vitro and tube penetration into silk were inhibited by xylose but not glucose. The overall findings indicate that maize pollen coat xylanase facilitates pollen tube penetration into silk via enzymatic xylan hydrolysis.
Effects Of Frame Rates In Video Displays
NASA Technical Reports Server (NTRS)
Kellogg, Gary V.; Wagner, Charles A.
1991-01-01
Report describes experiment on subjective effects of rates at which display on cathode-ray tube in flight simulator updated and refreshed. Conducted to learn more about jumping, blurring, flickering, and multiple lines that observer perceives when line moves at high speed across screen of a calligraphic CRT.
Ultrasonic technique for detection of liquids in copper tubing process lines
NASA Astrophysics Data System (ADS)
Dudley, W. A.
1980-10-01
An ultrasonic pulse-echo method developed for semiquantitative measurement of liquid levels in copper tubing is described. This ultrasonic approach is of particular value when used as a pre-maintenance diagnostic tool in repairing process lines containing hazardous liquids. Performance tests show that water and similar liquids can be directly detected to fill levels as low as 1/16 in. For water fills below 1/16 in., direct level detection is impractical because of signal resolution limitations. However, this fill condition is indirectly measurable and is detected by the effect of observed degradation of the adjacent wall echo pattern. Fill conditions for liquids associated with high sound attenuation such as oil can be indirectly determined.
Hurley, J.P.; McCollor, D.P.; Selle, S.J.
1994-07-26
A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during soot blowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon. 8 figs.
Hurley, John P.; McCollor, Don P.; Selle, Stanley J.
1994-01-01
A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during sootblowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon.
50 CFR 679.24 - Gear limitations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... contrasting color visible above the water line and shall be maintained so the markings are clearly visible. (b... material that is brightly colored, UV-protected plastic tubing or 3/8 inch polyester line or material of an... of wind. (7) Have streamers constructed of material that is brightly colored, UV-protected plastic...
French Regulatory practice and experience feedback on steam generator tube integrity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandon, G.
1997-02-01
This paper summarizes the way the French Safety Authority applies regulatory rules and practices to the problem of steam generator tube cracking in French PWR reactors. There are 54 reactors providing 80% of French electrical consumption. The Safety Authority closely monitors the performance of tubes in steam generators, and requires application of a program which deals with problems prior to the actual development of leakage. The actual rules regarding such performance are flexible, responding to the overall performance of operating steam generators. In addition there is an inservice inspection service to examine tubes during shutdown, and to monitor steam generatorsmore » for leakage during operation, with guidelines for when generators must be pulled off line.« less
Coolant tube curvature effects on film cooling as detected by infrared imagery
NASA Technical Reports Server (NTRS)
Papell, S. S.; Graham, R. W.
1979-01-01
Reported herein are comparative thermal film cooling footprints observed by infrared imagery from straight, curved and looped coolant tube geometries. It was hypothesized that the difference in secondary flow and turbulence structure of flow through these three tubes should influence the mixing properties between the coolant and mainstream. The coolant was injected across an adiabatic plate through a hole angled at 30 deg to the surface in line with the free stream flow. The data cover a range of blowing rates from 0.37 to 1.25 (mass flow per unit area of coolant divided by free stream). Average temperature difference between coolant and tunnel air was 25 C. Data comparisons confirmed that coolant tube curvature significantly influences film cooling effectiveness.
Ambient occlusion effects for combined volumes and tubular geometry.
Schott, Mathias; Martin, Tobias; Grosset, A V Pascal; Smith, Sean T; Hansen, Charles D
2013-06-01
This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.
Analytical and numerical performance models of a Heisenberg Vortex Tube
NASA Astrophysics Data System (ADS)
Bunge, C. D.; Cavender, K. A.; Matveev, K. I.; Leachman, J. W.
2017-12-01
Analytical and numerical investigations of a Heisenberg Vortex Tube (HVT) are performed to estimate the cooling potential with cryogenic hydrogen. The Ranque-Hilsch Vortex Tube (RHVT) is a device that tangentially injects a compressed fluid stream into a cylindrical geometry to promote enthalpy streaming and temperature separation between inner and outer flows. The HVT is the result of lining the inside of a RHVT with a hydrogen catalyst. This is the first concept to utilize the endothermic heat of para-orthohydrogen conversion to aid primary cooling. A review of 1st order vortex tube models available in the literature is presented and adapted to accommodate cryogenic hydrogen properties. These first order model predictions are compared with 2-D axisymmetric Computational Fluid Dynamics (CFD) simulations.
Ambient Occlusion Effects for Combined Volumes and Tubular Geometry
Schott, Mathias; Martin, Tobias; Grosset, A.V. Pascal; Smith, Sean T.; Hansen, Charles D.
2013-01-01
This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed. PMID:23559506
Lava Tube Seismicity at Kilauea
NASA Astrophysics Data System (ADS)
Hoblitt, R. P.; Battaglia, J.; Kauahikaua, J. P.; Okubo, P. G.
2002-12-01
We have begun to collect seismic data on lava tubes at Kilauea volcano in an effort to develop a real-time method for monitoring lava tube flux. Utilizing seismometers whose responses collectively vary from about 1 Hz to 1000 Hz, we find that most tube signals range between about 1 to 150 Hz, though some sites exhibit transient signals that range upward to several hundred Hz or more. Part of the lower frequency band--perhaps 1-10 Hz--may be volcanic tremor from Pu`u `O`o, the source of the lava flowing in the tubes. We attribute the higher frequencies to flowing lava, though wind noise and helicopter noise complicate interpretation. At a given site, both the amplitude and frequency spectrum change with time. We strongly suspect that at least some of the changes are related to changes in lava velocity and/or lava flux. Our strongest evidence that the part of the spectrum greater than 10 Hz contains velocity/flux information is that the signal amplitude of this band decreased by about 90 percent when the independently measured VLF (Very Low Frequency) tube flux decreased from about 300,000 m3/day in early February, 2002 to less than 5,000 m3/day in late August. Qualitative field observations of this tube system are in agreement with the VLF measurements.
Four cavity efficiency enhanced magnetically insulated line oscillator
Lemke, Raymond W.; Clark, Miles C.; Calico, Steve E.
1998-04-21
A four cavity, efficient magnetically insulated line oscillator (C4-E MILO) having seven vanes and six cavities formed within a tube-like structure surrounding a cathode. The C4-E MILO has a primary slow wave structure which is comprised of four vanes and the four cavities located near a microwave exit end of the tube-like structure. The primary slow wave structure is the four cavity (C4) portion of the magnetically insulated line oscillator (MILO). An RF choke is provided which is comprised of three of the vanes and two of the cavities. The RF choke is located near a pulsed power source portion of the tube-like structure surrounding the cathode. The RF choke increases feedback in the primary slow wave structure, prevents microwaves generated in the primary slow wave structure from propagating towards the pulsed power source and modifies downstream electron current so as to enhance microwave power generation. A beam dump/extractor is located at the exit end of the oscillator tube for extracting microwave power from the oscillator, and in conjunction with an RF extractor vane, which comprises the fourth vane of the primary slow wave structure (nearest the exit) having a larger gap radius than the other vanes of the primary SWS, comprises an RF extractor. Uninsulated electron flow is returned downstream towards the exit along an anode/beam dump region located between the beam dump/extractor and the exit where the RF is radiated at said RF extractor vane located near the exit and the uninsulated electron flow is disposed at the beam dump/extractor.
Four cavity efficiency enhanced magnetically insulated line oscillator
Lemke, R.W.; Clark, M.C.; Calico, S.E.
1998-04-21
A four cavity, efficient magnetically insulated line oscillator (C4-E MILO) having seven vanes and six cavities formed within a tube-like structure surrounding a cathode is disclosed. The C4-E MILO has a primary slow wave structure which is comprised of four vanes and the four cavities located near a microwave exit end of the tube-like structure. The primary slow wave structure is the four cavity portion of the magnetically insulated line oscillator (MILO). An RF choke is provided which is comprised of three of the vanes and two of the cavities. The RF choke is located near a pulsed power source portion of the tube-like structure surrounding the cathode. The RF choke increases feedback in the primary slow wave structure, prevents microwaves generated in the primary slow wave structure from propagating towards the pulsed power source and modifies downstream electron current so as to enhance microwave power generation. A beam dump/extractor is located at the exit end of the oscillator tube for extracting microwave power from the oscillator, and in conjunction with an RF extractor vane, which comprises the fourth vane of the primary slow wave structure (nearest the exit) having a larger gap radius than the other vanes of the primary SWS, comprises an RF extractor. Uninsulated electron flow is returned downstream towards the exit along an anode/beam dump region located between the beam dump/extractor and the exit where the RF is radiated at said RF extractor vane located near the exit and the uninsulated electron flow is disposed at the beam dump/extractor. 34 figs.
Smith, Simeon L.; Titze, Ingo R.
2016-01-01
Objectives To characterize the pressure-flow relationship of tubes used for semi-occluded vocal tract voice training/therapy, as well as to answer these major questions: (1) What is the relative importance of tube length to tube diameter? (2) What is the range of oral pressures achieved with tubes at phonation flow rates? (3) Does mouth configuration behind the tubes matter? Methods Plastic tubes of various diameters and lengths were mounted in line with an upstream pipe, and the pressure drop across each tube was measured at stepwise increments in flow rate. Basic flow theory and modified flow theory equations were used to describe the pressure-flow relationship of the tubes based on diameter and length. Additionally, the upstream pipe diameter was varied to explore how mouth shape affects tube resistance. Results The modified equation provided an excellent prediction of the pressure-flow relationship across all tube sizes (6% error compared to the experimental data). Variation in upstream pipe diameter yielded up to 10% deviation in pressure for tube sizes typically used in voice training/therapy. Conclusions Using the presented equations, resistance can be characterized for any tube based on diameter, length, and flow rate. With regard to the original questions, we found that: (1) For commonly used tubes, diameter is the critical variable for governing flow resistance; (2) For phonation flow rates, a range of tube dimensions produced pressures between 0 and 7.0 kPa; (3) The mouth pressure behind the lips will vary slightly with different mouth shapes, but this effect can be considered relatively insignificant. PMID:27133001
An improved water-filled impedance tube.
Wilson, Preston S; Roy, Ronald A; Carey, William M
2003-06-01
A water-filled impedance tube capable of improved measurement accuracy and precision is reported. The measurement instrument employs a variation of the standardized two-sensor transfer function technique. Performance improvements were achieved through minimization of elastic waveguide effects and through the use of sound-hard wall-mounted acoustic pressure sensors. Acoustic propagation inside the water-filled impedance tube was found to be well described by a plane wave model, which is a necessary condition for the technique. Measurements of the impedance of a pressure-release terminated transmission line, and the reflection coefficient from a water/air interface, were used to verify the system.
Operating a Geiger Müller tube using a PC sound card
NASA Astrophysics Data System (ADS)
Azooz, A. A.
2009-01-01
In this paper, a simple MATLAB-based PC program that enables the computer to function as a replacement for the electronic scalar-counter system associated with a Geiger-Müller (GM) tube is described. The program utilizes the ability of MATLAB to acquire data directly from the computer sound card. The signal from the GM tube is applied to the computer sound card via the line in port. All standard GM experiments, pulse shape and statistical analysis experiments can be carried out using this system. A new visual demonstration of dead time effects is also presented.
Han, K. J.; McCormick, M. E.; Derouen, S. M.; Blouin, D. C.
2014-01-01
In southeastern regions of the US, herbage systems are primarily based on grazing or hay feeding with low nutritive value warm-season perennial grasses. Nutritious herbage such as annual ryegrass (Lolium multiflorum Lam.) may be more suitable for preserving as baleage for winter feeding even with more intensive production inputs. Emerging in-line wrapped baleage storage systems featuring rapid wrapping and low polyethylene film requirements need to be tested for consistency of storing nutritive value of a range of annual ryegrass herbage. A ryegrass storage trial was conducted with 24-h wilted ‘Marshall’ annual ryegrass harvested at booting, heading and anthesis stages using three replicated in-line wrapped tubes containing ten round bales per tube. After a six-month storage period, nutritive value changes and fermentation end products differed significantly by harvest stage but not by bale location. Although wilted annual ryegrass exhibited a restricted fermentation across harvest stages characterized by high pH and low fermentation end product concentrations, butyric acid concentrations were less than 1 g/kg dry matter, and lactic acid was the major organic acid in the bales. Mold coverage and bale aroma did not differ substantially with harvest stage or bale location. Booting and heading stage-harvested ryegrass baleage were superior in nutritive value to anthesis stage-harvested herbage. Based on the investigated nutritive value and fermentation characteristics, individual bale location within in-line tubes did not significantly affect preservation quality of ryegrass round bale silages. PMID:25178371
Han, K J; McCormick, M E; Derouen, S M; Blouin, D C
2014-09-01
In southeastern regions of the US, herbage systems are primarily based on grazing or hay feeding with low nutritive value warm-season perennial grasses. Nutritious herbage such as annual ryegrass (Lolium multiflorum Lam.) may be more suitable for preserving as baleage for winter feeding even with more intensive production inputs. Emerging in-line wrapped baleage storage systems featuring rapid wrapping and low polyethylene film requirements need to be tested for consistency of storing nutritive value of a range of annual ryegrass herbage. A ryegrass storage trial was conducted with 24-h wilted 'Marshall' annual ryegrass harvested at booting, heading and anthesis stages using three replicated in-line wrapped tubes containing ten round bales per tube. After a six-month storage period, nutritive value changes and fermentation end products differed significantly by harvest stage but not by bale location. Although wilted annual ryegrass exhibited a restricted fermentation across harvest stages characterized by high pH and low fermentation end product concentrations, butyric acid concentrations were less than 1 g/kg dry matter, and lactic acid was the major organic acid in the bales. Mold coverage and bale aroma did not differ substantially with harvest stage or bale location. Booting and heading stage-harvested ryegrass baleage were superior in nutritive value to anthesis stage-harvested herbage. Based on the investigated nutritive value and fermentation characteristics, individual bale location within in-line tubes did not significantly affect preservation quality of ryegrass round bale silages.
NASA Astrophysics Data System (ADS)
Minato, Shohei; Ghose, Ranajit; Tsuji, Takeshi; Ikeda, Michiharu; Onishi, Kozo
2016-04-01
Tube waves are low frequency guided waves that propagate along a fluid-filled borehole. The analysis of tube waves is a promising approach to image and characterize hydraulic fractures intersecting a borehole. It exploits tube waves generated by an external seismic wavefield which compresses fractures and injects fluid into the borehole. It also utilizes the attenuation of tube waves due to fluid exchange between the fracture and the borehole, which creates scattered waves (reflection and transmission). Conventional approaches consider tube waves due to a single fracture. However, when the spacing between multiple fractures is short relative to the wavelength of the tube waves, the generated and scattered tube waves interfere with each other, making it difficult to isolate the effect of a single fracture. The analysis of closely spaced fractures is important in highly fractured areas, such as a fault zone. In this study, we explore the possibility of prediction and utilization of generated and scattered tube waves due to multiple fractures. We derive a new integral equation of the full tube wavefield using 1D wavefield representation theory incorporating nonwelded interfaces. We adapt the recent developments in modeling tube wave generation/scattering at a fracture. In these models, a fracture is represented as a parallel wall or a thin poloelastic layer. This allowed us to consider the effects of a dynamic fracture aperture with fracture compliances and the permeability. The representation also leads to a new imaging method for the hydraulic fractures, using multiply-generated and scattered tube waves. This is achieved by applying an inverse operator to the observed tube waves, which focuses the tube waves to the depth where they are generated and/or scattered. The inverse operator is constructed by a tube wave Green's function with a known propagation velocity. The Median Tectonic Line (MTL) is the most significant fault in Japan, extending NE-SW for over 1000 km across the Japanese Islands. We observed multiple tube waves in a P-wave VSP experiment in a 250 m deep, vertical borehole located on the MTL at Shikoku, Japan. The borehole televiewer and the core studies show that below 40 m depth, the Sambagawa metamorphic rocks contain highly fractured zones which consist of more than 100 open fractures and more than 30 cataclasites. We predict the full tube wavefield using the values of fracture depth and thickness known from the borehole televiewer. We model the open fractures as parallel-wall fractures and the cataclasites as thin poroelastic layers. Furthermore, we estimate the depth of the hydraulic fractures by applying the inverse operator. The results show that the tube waves could be generated and scattered at these permeable structures. Our preliminary results also indicate the possibility that the effect of the open fractures is more dominant in the generation and scattering of tube waves than that of the cataclasites in this field. The formulation and the results presented in this study and the following discussion will be useful in analysis of tube waves in highly fractured zones, in order to localize and characterize hydraulic fractures.
Cryogenic thermal emittance measurements on small-diameter stainless steel tubing
NASA Astrophysics Data System (ADS)
Jahromi, Amir E.; Tuttle, James G.; Canavan, Edgar R.
2017-12-01
The Mid Infrared Instrument aboard the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of ~2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by running a warm gas through the lines to sublimate the frozen water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the absorptance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 280 K. These values lead to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing
NASA Technical Reports Server (NTRS)
Jahromi, Amir E.; Tuttle, James G.; Canavan, Edgar R.
2017-01-01
The Mid Infrared Instrument aboard the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by running a warm gas through the lines to sublimate the frozen water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the absorptance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 280 K. These values lead to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
NASA Astrophysics Data System (ADS)
Caughley, A.; Meier, J.; Nation, M.; Reynolds, H.; Boyle, C.; Tanchon, J.
2017-12-01
Fabrum Solutions, in collaboration with Absolut System and Callaghan Innovation, produce a range of large pulse tube cryocoolers based on metal diaphragm pressure wave generator technology (DPWG). The largest cryocooler consists of three in-line pulse tubes working in parallel on a 1000 cm3 swept volume DPWG. It has demonstrated 1280 W of refrigeration at 77 K, from 24 kW of input power and was subsequently incorporated into a liquefaction plant to produce liquid nitrogen for an industrial customer. The pulse tubes on the large cryocooler each produced 426 W of refrigeration at 77 K. However, pulse tubes can produce more refrigeration with higher efficiency at higher temperatures. This paper presents the results from experiments to increase overall liquefaction throughput by operating one or more pulse tubes at a higher temperature to pre-cool the incoming gas. The experiments showed that the effective cooling increased to 1500 W resulting in an increase in liquefaction rate from 13 to 16 l/hour.
NASA Astrophysics Data System (ADS)
Minato, Shohei; Ghose, Ranajit; Tsuji, Takeshi; Ikeda, Michiharu; Onishi, Kozo
2017-10-01
Fluid-filled fractures and fissures often determine the pathways and volume of fluid movement. They are critically important in crustal seismology and in the exploration of geothermal and hydrocarbon reservoirs. We introduce a model for tube wave scattering and generation at dipping, parallel-wall fractures intersecting a fluid-filled borehole. A new equation reveals the interaction of tube wavefield with multiple, closely spaced fractures, showing that the fracture dip significantly affects the tube waves. Numerical modeling demonstrates the possibility of imaging these fractures using a focusing analysis. The focused traces correspond well with the known fracture density, aperture, and dip angles. Testing the method on a VSP data set obtained at a fault-damaged zone in the Median Tectonic Line, Japan, presents evidences of tube waves being generated and scattered at open fractures and thin cataclasite layers. This finding leads to a new possibility for imaging, characterizing, and monitoring in situ hydraulic properties of dipping fractures using the tube wavefield.
Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing
NASA Technical Reports Server (NTRS)
Jahromi, A. E.; Tuttle, J. G.; Canavan, E. R.
2017-01-01
The Mid Infrared Instrument aboard the James Webb Space Telescoep includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of approximately 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by a running a warm gas through the lines to sublimate the water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the abosprtance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 300 K. This value leads to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
Dynamics of magnetic flux tubes in an advective flow around a black hole
NASA Astrophysics Data System (ADS)
Deb, Arnab; Giri, Kinsuk; Chakrabarti, Sandip K.
2017-12-01
Entangled magnetic fields entering into an accretion flow would very soon be stretched into a dominant toroidal component due to strong differentially rotating motion inside the accretion disc. This is particularly true for weakly viscous, low angular momentum transonic or advective discs. We study the trajectories of toroidal flux tubes inside a geometrically thick flow that undergoes a centrifugal force supported shock. We also study effects of these flux tubes on the dynamics of the inflow and the outflow. We use a finite difference method (total variation diminishing) for this purpose and specifically focused on whether these flux tubes significantly affect the properties of the outflows such as its collimation and the rate. It is seen that depending upon the cross-sectional radius of the flux tubes that control the drag force, these field lines may move towards the central object or oscillate vertically before eventually escaping out of the funnel wall (pressure zero surfaces) along the vertical direction. A comparison of results obtained with and without flux tubes show these flux tubes could play a pivotal role in collimation and acceleration of jets and outflows.
Energy-absorption capability and scalability of square cross section composite tube specimens
NASA Technical Reports Server (NTRS)
Farley, Gary L.
1987-01-01
Static crushing tests were conducted on graphite/epoxy and Kevlar/epoxy square cross section tubes to study the influence of specimen geometry on the energy-absorption capability and scalability of composite materials. The tube inside width-to-wall thickness (W/t) ratio was determined to significantly affect the energy-absorption capability of composite materials. As W/t ratio decreases, the energy-absorption capability increases nonlinearly. The energy-absorption capability of Kevlar epoxy tubes was found to be geometrically scalable, but the energy-absorption capability of graphite/epoxy tubes was not geometrically scalable.
Density Enhancements and Voids Following Patchy Reconnection
NASA Astrophysics Data System (ADS)
Guidoni, S. E.; Longcope, D. W.
2011-04-01
We show, through a simple patchy reconnection model, that retracting reconnected flux tubes may present elongated regions relatively devoid of plasma, as well as long lasting, dense central hot regions. Reconnection is assumed to happen in a small patch across a Syrovatskiiˇ (non-uniform) current sheet (CS) with skewed magnetic fields. The background magnetic pressure has its maximum at the center of the CS plane and decreases toward its edges. The reconnection patch creates two V-shaped reconnected tubes that shorten as they retract in opposite directions, due to magnetic tension. One of them moves upward toward the top edge of the CS, and the other one moves downward toward the top of the underlying arcade. Rotational discontinuities (RDs) propagate along the legs of the tubes and generate parallel supersonic flows that collide at the center of the tube. There, gas-dynamic shocks that compress and heat the plasma are launched outwardly. The descending tube moves through the bottom part of the CS where it expands laterally in response to the decreasing background magnetic pressure. This effect may decrease plasma density by 30%-50% of background levels. This tube will arrive at the top of the arcade that will slow it to a stop. Here, the perpendicular dynamics is halted, but the parallel dynamics continues along its legs; the RDs are shut down, and the gas is rarified to even lower densities. The hot post-shock regions continue evolving, determining a long lasting hot region on top of the arcade. We provide an observational method based on total emission measure and mean temperature that indicates where in the CS the tube has been reconnected.
Experimental Characterisation of a Pulse Tube Cryocooler for Ground Applications
NASA Astrophysics Data System (ADS)
Charles, I.; Duband, L.; Martin, J.-Y.; Mullié, J. C.; Bruins, P. C.
2004-06-01
Developments on high frequency high heat lift pulse tubes are carried out at CEA/SBT. Based on a previous study on an in line configuration, two new pulse tube cold fingers have been manufactured: a coaxial configuration and a U-shape configuration. Measurements performed with the coaxial configuration have demonstrated cooling power in excess of 6 W at 80 K with 140 W of mechanical input power. The results obtained with these two configurations are presented. The impact of the rejection temperature has also been studied and is discussed. In parallel, a new compressor with pistons supported by flexure bearings has been designed and manufactured. This compressor has been coupled with the pulse tube. Tests performed with the new developed flexure-bearing compressors and a conventional compressor are presented and compared. The pulse tube cold finger associated with the new compressor leads to a reliable and low vibration cooler.
a High Frequency Thermoacoustically-Driven Pulse Tube Cryocooler with Coaxial Resonator
NASA Astrophysics Data System (ADS)
Yu, G. Y.; Wang, X. T.; Dai, W.; Luo, E. C.
2010-04-01
High frequency thermoacoustically-driven pulse tube cryocoolers are quite promising due to their compact size and high reliability, which can find applications in space use. With continuous effort, a lowest cold head temperature of 68.3 K has been obtained on a 300 Hz pulse tube cryocooler driven by a standing-wave thermoacoustic heat engine with 4.0 MPa helium gas and 750 W heat input. To further reduce the size of the system, a coaxial resonator was designed and the two sub-systems, i.e., the pulse tube cryocooler and the standing-wave thermoacoustic heat engine were properly coupled through an acoustic amplifier tube, which leads to a system axial length of only about 0.7 m. The performance of the system with the coaxial resonator was tested, and shows moderate degradation compared to that with the in-line resonator, which might be attributed to the large flow loss of the 180 degree corner.
Recirculating 1-K-Pot for Pulse-Tube Cryostats
NASA Technical Reports Server (NTRS)
Paine, Christopher T.; Naylor, Bret J.; Prouve, Thomas
2013-01-01
A paper describes a 1-K-pot that works with a commercial pulse tube cooler for astrophysics instrumentation testbeds that require temperatures <1.7 K. Pumped liquid helium-4 cryostats were commonly used to achieve this temperature. However, liquid helium-4 cryostats are being replaced with cryostats using pulse tube coolers. The closed-cycle 1K-pot system for the pulse tube cooler requires a heat exchanger on the pulse tube, a flow restriction, pump-out line, and pump system that recirculates helium-4. The heat exchanger precools and liquefies helium- 4 gas at the 2.5 to 3.5 K pulse tube cold head. This closed-cycle 1-K-pot system was designed to work with commercially available laboratory pulse tube coolers. It was built using common laboratory equipment such as stainless steel tubing and a mechanical pump. The system is self-contained and requires only common wall power to operate. The lift of 15 mW at 1.1 K and base temperature of 0.97 K are provided continuously. The system can be scaled to higher heat lifts of .30 to 50 mW if desired. Ground-based telescopes could use this innovation to improve the efficiency of existing cryo
A Safe and Interactive Method of Illuminating Discharge Tubes for Studying Emission Spectra
ERIC Educational Resources Information Center
Lu, Zhe
2012-01-01
Discharge tubes are useful tools for teaching emission spectra and the discrete energy levels of the Bohr model. A new setup uses a plasma globe to illuminate the discharge tube and allows a higher degree of interactivity owing to the omission of a traditional, high-voltage power source. The decreased power consumption also reduces the heating of…
Crespo, Elena; Devasena, Samudrala; Sikkens, Cor; Centeno, Raymund; Cristescu, Simona M; Harren, Frans J M
2012-04-30
When performing trace gas analysis, it is not always possible to bring the source of volatiles and the gas analyzer together. In these cases, volatile storage containers, such as thermal desorption (TD) tubes, can be used for off-line measurement. TD is routinely combined with gas chromatography/mass spectrometry (GC/MS), but so far not with proton-transfer reaction mass spectrometry (PTRMS), which has a faster response. A PTR-quadrupole-MS instrument and a PTR-ion-trap-MS instrument were separately coupled to a TD unit for off-line analysis of trace volatiles in air. Carbograph 1TD/Carbopack X sorbent tubes were filled with different concentrations of a trace gas mixture containing low molecular weight volatiles (32 g/mol up to 136 g/mol) and measured with the above-mentioned combinations. The carrier gas in the TD unit was changed from helium to nitrogen to be able to combine this instrument with the mass spectrometer. Good linearity and reproducibility with the amount of gas stored were obtained. The storage capacity over time (up to 14 days) showed larger variability (<11% for all compounds, except for acetone 27%). Several tubes were filled with breath of different persons, and the breath of a smoker showed increased levels of acetonitrile and benzene. The combination of the PTR ion-trap instrument with the TD unit was also investigated. Due to its higher sampling rate, the ion-trap system showed higher throughput capabilities than the quadrupole system. The combination of TD with PTRMS using both a quadrupole and an ion trap for off-line volatile analysis has been validated. TD tubes can be a robust and compact volatile storage method when the mass spectrometry and the sampling cannot be performed in the same place, for example in large screening studies. In addition, a higher measurement throughput than with GC/MS could be obtained. Copyright © 2012 John Wiley & Sons, Ltd.
Maury, Eric; Vitry, Paola; Galbois, Arnauld; Ait-Oufella, Hafid; Baudel, Jean-Luc; Guidet, Bertrand; Offenstadt, Georges
2012-06-14
We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device. We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin]. Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71-48.8; p < 0.001). The administration of on-demand medication through tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutton, R.D.
1994-01-01
As part of the particle- and momentum-tagging instrumentation required for the test beam lines of the Superconducting Super Collider (SSC), the synchrotron radiation detector (SRD) was designed to provide electron tagging at momentum above 75 GeV. In a parallel effort to the three test beam lines at the SSC, schedule demands required testing and calibration operations to be initiated at Fermilab. Synchrotron radiation detectors also were to be installed in the NM and MW beam lines at Femilab before the test beam lines at the SSC would become operational. The SRD is the last instrument in a series of threemore » used in the SSC test beam fines. It follows a 20-m drift section of beam tube downstream of the last silicon strip detector. A bending dipole just in of the last silicon strip detector produces the synchrotron radiation that is detected in a 50-mm-square cross section NaI crystal. A secondary scintillator made of Bicron BC-400 plastic is used to discriminate whether it is synchrotron radiation or a stray particle that causes the triggering of the NaI crystal`s photo multiplier tube (PMT).« less
Comparison of δ18O measurements in nitrate by different combustion techniques
Revesz, Kinga; Böhlke, John Karl
2002-01-01
Three different KNO3 salts with δ18O values ranging from about −31 to +54‰ relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with δ18O values in the midpoint of the δ18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25‰). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the δ18O scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with δ18O values far from that of atmospheric O2, to improve interlaboratory comparability.
Project SQUID. Quarterly Progress Report
1949-07-01
the sodium line reversal method for flame temperature determination ., Determination of Point Temperatures in Turbulent Flames Using the Sodium Line...taken to determine the approximate position of the line. Then, with the G-M tube in position and using the photo graph as an indicator, the region... beams are wide, the latter yielding a greater source of X-rays. Hence, by using that window yielding the broadest beam greater intensity of X-rays
Froelich, Daniel R; Mullendore, Daniel L; Jensen, Kåre H; Ross-Elliott, Tim J; Anstead, James A; Thompson, Gary A; Pélissier, Hélène C; Knoblauch, Michael
2011-12-01
Since the first ultrastructural investigations of sieve tubes in the early 1960s, their structure has been a matter of debate. Because sieve tube structure defines frictional interactions in the tube system, the presence of P protein obstructions shown in many transmission electron micrographs led to a discussion about the mode of phloem transport. At present, it is generally agreed that P protein agglomerations are preparation artifacts due to injury, the lumen of sieve tubes is free of obstructions, and phloem flow is driven by an osmotically generated pressure differential according to Münch's classical hypothesis. Here, we show that the phloem contains a distinctive network of protein filaments. Stable transgenic lines expressing Arabidopsis thaliana Sieve-Element-Occlusion-Related1 (SEOR1)-yellow fluorescent protein fusions show that At SEOR1 meshworks at the margins and clots in the lumen are a general feature of living sieve tubes. Live imaging of phloem flow and flow velocity measurements in individual tubes indicate that At SEOR1 agglomerations do not markedly affect or alter flow. A transmission electron microscopy preparation protocol has been generated showing sieve tube ultrastructure of unprecedented quality. A reconstruction of sieve tube ultrastructure served as basis for tube resistance calculations. The impact of agglomerations on phloem flow is discussed.
Froelich, Daniel R.; Mullendore, Daniel L.; Jensen, Kåre H.; Ross-Elliott, Tim J.; Anstead, James A.; Thompson, Gary A.; Pélissier, Hélène C.; Knoblauch, Michael
2011-01-01
Since the first ultrastructural investigations of sieve tubes in the early 1960s, their structure has been a matter of debate. Because sieve tube structure defines frictional interactions in the tube system, the presence of P protein obstructions shown in many transmission electron micrographs led to a discussion about the mode of phloem transport. At present, it is generally agreed that P protein agglomerations are preparation artifacts due to injury, the lumen of sieve tubes is free of obstructions, and phloem flow is driven by an osmotically generated pressure differential according to Münch’s classical hypothesis. Here, we show that the phloem contains a distinctive network of protein filaments. Stable transgenic lines expressing Arabidopsis thaliana Sieve-Element-Occlusion-Related1 (SEOR1)–yellow fluorescent protein fusions show that At SEOR1 meshworks at the margins and clots in the lumen are a general feature of living sieve tubes. Live imaging of phloem flow and flow velocity measurements in individual tubes indicate that At SEOR1 agglomerations do not markedly affect or alter flow. A transmission electron microscopy preparation protocol has been generated showing sieve tube ultrastructure of unprecedented quality. A reconstruction of sieve tube ultrastructure served as basis for tube resistance calculations. The impact of agglomerations on phloem flow is discussed. PMID:22198148
Kauahikaua, J.; Mangan, M.; Heliker, C.; Mattox, T.
1996-01-01
The Kupaianaha vent, the source of the 48th episode of the 1983-to-present Pu'u 'O'o-Kupaianaha eruption, erupted nearly continuously from July 1986 until February 1992. This investigation documents the geophysical and geologic monitoring of the final 10 months of activity at the Kupaianaha vent. Detailed very low frequency (VLF) electromagnetic profiles across the single lava tube transporting lava from the vent were used to determine the cross-sectional area of the molten lava within the tube. Combined with measurements of lava velocity, these data provide an estimate of the lava output of Kupaianaha. In addition, lava temperatures (calculated from analysis of quenched glass) and bulk-rock chemistry were obtained for samples taken from the tube at the same site. The combined data set shows the lava flux from Kupaianaha vent declining linearly from 250000 m3/day in April 1991 to 54000 m3/day by November 1991. During that time surface breakouts of lava from weak points along the tube occurred progressively closer to the vent, consistent with declining efficiency in lava transport. There were no significant changes in lava temperature or in bulk MgO content during this period. Another eruptive episode (the 49th) began uprift of Kupaianaha on 8 November 1991 and erupted lava concurrently with Kupaianaha for 18 days. Lava flux from Kupaianaha decreased in response to this new episode, but the response was delayed by approximately 1 day. After 14 November 1991, lava velocities were no longer measurable in the tube because the lava stream beneath the skylight had crusted over; however, the VLF-derived electrical conductances documented the decreasing flux of molten lava through the tube. Kupaianaha remained active, but output continued to decrease until early February 1992 when the last active surface flows were seen. In November 1991 we used the linearly decreasing effusion rate to accurately predict the date for the death of the Kupaianaha vent. The linear nature of the decline in lava tube conductance and the delayed and slow response of the Waha'ula tube conductances to the 49th eruptive episode led us to speculate that (a) the Kupaianaha vent shut down because of a decrease in driving pressure and not because of a freeze-up of the vent, and (b) that Pu'u 'O'o, episode 49, and Kupaianaha were fed nearly vertically from a source deep within the rift zone.
NASA Astrophysics Data System (ADS)
Kauahikaua, J.; Mangan, M.; Heliker, C.; Mattox, T.
1996-07-01
The Kupaianaha vent, the source of the 48th episode of the 1983-to-present Pu'u 'O'o Kupaianaha eruption, erupted nearly continuously from July 1986 until February 1992. This investigation documents the geophysical and geologic monitoring of the final 10 months of activity at the Kupaianaha vent. Detailed very low frequency (VLF) electromagnetic profiles across the single lava tube transporting lava from the vent were used to determine the cross-sectional area of the molten lava within the tube. Combined with measurements of lava velocity, these data provide an estimate of the lava output of Kupaianaha. In addition, lava temperatures (calculated from analysis of quenched glass) and bulk-rock chemistry were obtained for samples taken from the tube at the same site. The combined data set shows the lava flux from Kupaianaha vent declining linearly from 250 000 m3/day in April 1991 to 54 000 m3/day by November 1991. During that time surface breakouts of lava from weak points along the tube occurred progressively closer to the vent, consistent with declining efficiency in lava transport. There were no significant changes in lava temperature or in bulk MgO content during this period. Another eruptive episode (the 49th) began uprift of Kupaianaha on 8 November 1991 and erupted lava concurrently with Kupaianaha for 18 days. Lava flux from Kupaianaha decreased in response to this new episode, but the response was delayed by approximately 1 day. After 14 November 1991, lava velocities were no longer measurable in the tube because the lava stream beneath the skylight had crusted over; however, the VLF-derived electrical conductances documented the decreasing flux of molten lava through the tube. Kupaianaha remained active, but output continued to decrease until early February 1992 when the last active surface flows were seen. In November 1991 we used the linearly decreasing effusion rate to accurately predict the date for the death of the Kupaianaha vent. The linear nature of the decline in lava tube conductance and the delayed and slow response of the Waha'ula tube conductances to the 49th eruptive episode led us to speculate that (a) the Kupaianaha vent shut down because of a decrease in driving pressure and not because of a freeze-up of the vent, and (b) that Pu'u 'O'o, episode 49, and Kupaianaha were fed nearly vertically from a source deep within the rift zone.
Sequentially pulsed traveling wave accelerator
Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA
2009-08-18
A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.
Adjustable Powder Injector For Vacuum Plasma Sprayer
NASA Technical Reports Server (NTRS)
Burns, D. H.; Woodford, W. H.; Mckechnie, T. N.; Mcferrin, D. C.; Davis, W. M.; Beason, G. P., Jr.
1993-01-01
Attachment for plasma spray gun provides four degrees of freedom for adjustment of position and orientation at which powder injected externally into plasma flame. Manipulator provides for adjustment of pitch angle of injection tube: set to inject powder at any angle ranging from perpendicular to parallel to cylindrical axis. Scribed lines on extension bar and manipulator indicate pitch angle of extension tube. Collar changed to adapt injector to different gun.
Plasma spectroscopy of uranium and tungsten, part 1
NASA Technical Reports Server (NTRS)
Wilkerson, T. D.
1973-01-01
Results of research on uranium and tungsten spectra are summarized. Measurements of visible line spectra and opacities were carried out on shock tube plasmas which, prior to shock compression, were mixtures of rare gases and UF6 or WF6. Opacities were compared to theoretical predictions. Feasibility of light source methods other than the shock tube was explored for future applications in the spectroscopy of heavy metals and ions.
Evaluation of DCS III Transmission Alternatives, Phase 1B.
1980-09-30
Most commonly used measure are straight and precision tubing, dielectric lining, and helix construction. These measures make the millimeter waveguide...channel tran- sistorized and microprocessor-controlled L5E. The broadband signal, either analog or digital, can be transmitted over a coaxial cable...kilowatts. One kind of mm source is travelling wave tubes ( TWT ) which are currently under development in the frequency range from 20 to 50 GHz with
Failure Surfaces for the Design of Ceramic-Lined Gun Tubes
2004-12-01
density than steel making them attractive candidates as gun tube liners . A new design approach is necessary to address the large variability in strength...systems. Having established the failure criterion for the ceramic liner as the Weibull probability of failure, the need for a suitable failure...Report AMMRC SP-82-1, Materials Technology Laboratory, Watertown, Massachusetts, 1982. 7 R. Katz, Ceramic Gun Barrel Liners : Retrospect and Prospect
A decrease in nasal CO2 stimulates breathing in the tegu lizard.
Coates, E L; Furilla, R A; Ballam, G O; Bartlett, D
1991-10-01
Tegu lizards decrease ventilatory frequency (f) when constant CO2, as low as 0.4%, is delivered to the nasal cavities. In contrast, CO2, as high as 6%, pulsed into the nasal cavities during the expiratory phase of the breathing cycle does not alter f. The purpose of the present study was to investigate further the effect of nasal CO2 pattern on f in tegu lizards. Specifically, we tested: (1) whether f was affected by CO2 delivered to the nasal cavities during the inspiratory phase of the breathing cycle, and (2) whether pulsed decreases in nasal CO2 from 4% to 2% and from 4% to 0% would remove the f inhibition caused by constant nasal CO2. Ventilation was measured using a pneumotachograph and pressure transducer in-line with an endotracheal T-tube inserted through the glottis. CO2 was delivered to the nasal cavities through small tubes inserted into the external nares. Ventilatory frequency was not significantly altered when 4% CO2 was pulsed into the nasal cavities during inspiration. Dropping the CO2 in the nasal cavities from 4% to 0% at either 15 cycles/min (0.25 Hz) or for one cycle stimulated breathing. There was no significant difference between the f response to a drop in CO2 from 4% to 0% and that to a drop in CO2 from 4% to 2%. The failure to link the phasic CO2 ventilatory response to a phase in the respiratory cycle indicates that the nasal CO2 receptors do not participate in the breath-by-breath regulation of breathing in these lizards. The observation that small decreases in nasal CO2 abolished the f inhibition caused by constant nasal CO2 provides further evidence for the ability of the nasal CO2 receptors to distinguish between pulsed and constant CO2.
Bennett, Charles L.
2010-06-15
A solar thermal power generator includes an inclined elongated boiler tube positioned in the focus of a solar concentrator for generating steam from water. The boiler tube is connected at one end to receive water from a pressure vessel as well as connected at an opposite end to return steam back to the vessel in a fluidic circuit arrangement that stores energy in the form of heated water in the pressure vessel. An expander, condenser, and reservoir are also connected in series to respectively produce work using the steam passed either directly (above a water line in the vessel) or indirectly (below a water line in the vessel) through the pressure vessel, condense the expanded steam, and collect the condensed water. The reservoir also supplies the collected water back to the pressure vessel at the end of a diurnal cycle when the vessel is sufficiently depressurized, so that the system is reset to repeat the cycle the following day. The circuital arrangement of the boiler tube and the pressure vessel operates to dampen flow instabilities in the boiler tube, damp out the effects of solar transients, and provide thermal energy storage which enables time shifting of power generation to better align with the higher demand for energy during peak energy usage periods.
A simple on-line arterial time-activity curve detector for [O-15] water PET studies
NASA Astrophysics Data System (ADS)
Wollenweber, S. D.; Hichwa, R. D.; Ponto, L. L. B.
1997-08-01
A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAG) for bolus-injection [O-15] water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.
NASA Astrophysics Data System (ADS)
Yu, Z. J.; Russell, C. T.; Kivelson, M. G.; Khurana, K. K.
2000-10-01
Massloading of the jovian magnetosphere by the addition of ions at the moon Io is the ultimate engine of the circulation of the magnetospheric plasma. In steady state the radial density profile enables the radial outflow velocity to be calculated from the mass addition rate. Some of these ions are lost from the field lines through pitch angle diffusion. Expected loss rates can be calculated from the fluctuation level in the magnetic field. Radial velocities can be calculated from observations of the Europa wake and force balance in the magnetodisk. The resulting transport times are shorter than the pitch angle scattering loss times so that most of the plasma is transported to the tail and lost by magnetic island formation. In turn the island formation process (reconnection) depletes magnetic field lines making them buoyant and allowing them to "float" back to the inner magnetosphere. In the torus these depleted flux tubes can be seen as thin tubes with stronger than the ambient field strength, implying plasma pressures about 2% of the magnetic field and ion temperatures principally in the range 30-150 eV. When the depleted flux tubes reach the orbit of Io where the energy density of the plasma drops these depleted flux tubes become indistinguishable from the ambient plasma, completing the circulation loop.
Qu, Haiyong; Guan, Yaqin; Wang, Yongzhang; Zhang, Shaolin
2017-01-01
Among the Rosaceae species, the gametophytic self-incompatibility (GSI) is controlled by a single multi-allelic S locus, which is composed of the pistil-S and pollen-S genes. The pistil-S gene encodes a polymorphic ribonuclease (S-RNase), which is essential for identifying self-pollen. However, the S-RNase system has not been fully characterized. In this study, the self-S-RNase inhibited the Ca2+-permeable channel activity at pollen tube apices and the selectively decreased phospholipase C (PLC) activity in the plasma membrane of Pyrus pyrifolia pollen tubes. Self-S-RNase decreased the Ca2+ influx through a PLC-mediated signaling pathway. Phosphatidylinositol-specific PLC has a 26-amino acid insertion in pollen tubes of the ‘Jinzhuili’ cultivar, which is a spontaneous self-compatible mutant of the ‘Yali’ cultivar. ‘Yali’ plants exhibit a typical S-RNase-based GSI. Upon self-pollination, PLC gene expression is significantly higher in ‘Jinzhuili’ pollen tubes than that in ‘Yali’ pollen tubes. Moreover, the PLC in pollen tubes can only interact with one of the two types of S-RNase from the style. In the Pyrus x bretschneideri Rehd, the PLC directly interacted with the S7-RNase in the pollen tube, but not with the S34-RNase. Collectively, our results reveal that the effects of S-RNase on PLC activity are required for S-specific pollen rejection, and that PLC-IP3 participates in the self-incompatibility reaction of Pyrus species. PMID:28729872
Qu, Haiyong; Guan, Yaqin; Wang, Yongzhang; Zhang, Shaolin
2017-01-01
Among the Rosaceae species, the gametophytic self-incompatibility (GSI) is controlled by a single multi-allelic S locus, which is composed of the pistil-S and pollen-S genes. The pistil-S gene encodes a polymorphic ribonuclease (S-RNase), which is essential for identifying self-pollen. However, the S-RNase system has not been fully characterized. In this study, the self-S-RNase inhibited the Ca 2+ -permeable channel activity at pollen tube apices and the selectively decreased phospholipase C ( PLC ) activity in the plasma membrane of Pyrus pyrifolia pollen tubes. Self-S-RNase decreased the Ca 2+ influx through a PLC -mediated signaling pathway. Phosphatidylinositol-specific PLC has a 26-amino acid insertion in pollen tubes of the 'Jinzhuili' cultivar, which is a spontaneous self-compatible mutant of the 'Yali' cultivar. 'Yali' plants exhibit a typical S-RNase-based GSI. Upon self-pollination, PLC gene expression is significantly higher in 'Jinzhuili' pollen tubes than that in 'Yali' pollen tubes. Moreover, the PLC in pollen tubes can only interact with one of the two types of S-RNase from the style. In the Pyrus x bretschneideri Rehd, the PLC directly interacted with the S 7 -RNase in the pollen tube, but not with the S 34 -RNase. Collectively, our results reveal that the effects of S-RNase on PLC activity are required for S-specific pollen rejection, and that PLC -IP 3 participates in the self-incompatibility reaction of Pyrus species.
NASA Astrophysics Data System (ADS)
Kitazaki, Satoshi; Hayashi, Nobuya
2009-10-01
Oxygen and water vapor plasmas inside a narrow long tube were produced using an AC HV glow discharge at low pressure in order to sterilize the inner surface of a tube. In order to produce plasma inside a narrow tube, an AC high voltage was adopted. The material of the tube used in this experiment was silicon rubber. The length and diameter of the tubes ranged from 300 to 1,000 mm and from 1 to 4 mm, respectively. The tube was placed in a stainless steel vacuum chamber and was evacuated to 10 Pa using a rotary pump. The material gas for plasma and radical productions was pure oxygen or water vapor, which was introduced to the chamber from a gas cylinder or water reservoir. Light emission spectral lines of oxygen and OH radicals were observed at 777 nm and 306 nm, respectively. The chemical indicator was inserted into the tube and turned to a yellowish color (from the original red) after a treatment, which indicates the generation of sufficient oxygen on OH radicals for sterilization. A tube with the length of 500 mm and diameter of 4 mm is sterilized using oxygen plasma by 10 minutes treatment. Also a tube with the length of 300 mm and diameter of 2 mm is sterilized using water vapor plasma by 5 minutes treatment.
A shock-tube measurement of the SiO/E 1 Sigma + - X 1 Sigma +/ transition moment
NASA Technical Reports Server (NTRS)
Park, C.
1978-01-01
The sum of the squares of the electronic transition moments for the (E 1 Sigma +) - (X 1 Sigma +) band system of SiO has been determined from absorption measurements conducted in the reflected-shock region of a shock tube. The test gas produced by shock-heating a mixture of SiCl4, N2O, and Ar, and the spectra were recorded photographically in the 150-230-nm wavelength range. The values of the sum of the squares were determined by comparing the measured absorption spectra with those produced by a line-by-line synthetic spectrum calculation. The value so deduced at an r-centroid value of 3.0 bohr was 0.86 + or - 0.10 atomic unit.
Absorption Of Crushing Energy In Square Composite Tubes
NASA Technical Reports Server (NTRS)
Farley, Gary L.
1992-01-01
Report describes investigation of crash-energy-absorbing capabilities of square-cross-section tubes of two matrix/fiber composite materials. Both graphite/epoxy and Kevlar/epoxy tubes crushed in progressive and stable manner. Ratio between width of cross section and thickness of wall determined to affect energy-absorption significantly. As ratio decreases, energy-absorption capability increases non-linearly. Useful in building energy-absorbing composite structures.
The progamic phase of an early-divergent angiosperm, Annona cherimola (Annonaceae)
Lora, J.; Hormaza, J. I.; Herrero, M.
2010-01-01
Background and Aims Recent studies of reproductive biology in ancient angiosperm lineages are beginning to shed light on the early evolution of flowering plants, but comparative studies are restricted by fragmented and meagre species representation in these angiosperm clades. In the present study, the progamic phase, from pollination to fertilization, is characterized in Annona cherimola, which is a member of the Annonaceae, the largest extant family among early-divergent angiosperms. Beside interest due to its phylogenetic position, this species is also an ancient crop with a clear niche for expansion in subtropical climates. Methods The kinetics of the reproductive process was established following controlled pollinations and sequential fixation. Gynoecium anatomy, pollen tube pathway, embryo sac and early post-fertilization events were characterized histochemically. Key Results A plesiomorphic gynoecium with a semi-open carpel shows a continuous secretory papillar surface along the carpel margins, which run from the stigma down to the obturator in the ovary. The pollen grains germinate in the stigma and compete in the stigma-style interface to reach the narrow secretory area that lines the margins of the semi-open stylar canal and is able to host just one to three pollen tubes. The embryo sac has eight nuclei and is well provisioned with large starch grains that are used during early cellular endosperm development. Conclusions A plesiomorphic simple gynoecium hosts a simple pollen–pistil interaction, based on a support–control system of pollen tube growth. Support is provided through basipetal secretory activity in the cells that line the pollen tube pathway. Spatial constraints, favouring pollen tube competition, are mediated by a dramatic reduction in the secretory surface available for pollen tube growth at the stigma–style interface. This extramural pollen tube competition contrasts with the intrastylar competition predominant in more recently derived lineages of angiosperms. PMID:19939980
Surveys of arthropod and gastropod diversity in the geothermal resource subzones, Puna, Hawaii
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, S.E.; Burgett, J.; Bruegmann, M.
1995-04-01
The invertebrate surveys reported here were carried out as part of ecological studies funded by the Department of Energy in support of their environmental impact statement (EIS) for the Hawaii Geothermal Project. Currently, preparation of the EIS has been suspended, and all supporting information is being archived and made available to the public. The invertebrate surveys reported here assessed diversity and abundance of the arthropod and gastropod fauna in forested habitat and lava tubes in or near the three geothermal resource subzones. Recommendations for conservation of these organisms are given in this report. Surveys were conducted along three 100-m transectmore » lines at each of the six forested locations. Malaise traps, baited pitfall traps, yellow pan traps, baited sponge lures, and visual examination of vegetation were used to assess invertebrate diversity along each transect line. Three of these locations were adjacent to roads, and three were adjacent to lava flows. Two of these lava-forest locations (Keauohana Forest Reserve and Pu`u O`o) were relatively remote from direct human impacts. The third location (Southeast Kula) was near a low-density residential area. Two lava tubes were surveyed. The forest over one of these tubes (Keokea tube) had recently been burned away. This tube was used to assess the effects of loss of forest habitat on the subterranean fauna. An undisturbed tube (Pahoa tube) was used as a control. Recommendations offered in this report direct geothermal development away from areas of high endemic diversity and abundance, and toward areas where natural Hawaiian biotic communities have already been greatly disturbed. These disturbed areas are mainly found in the lower half of the Kamaili (middle) geothermal subzone and throughout most of the Kapoho (lower) geothermal subzone. These recommendation may also generally apply to other development projects in the Puna District.« less
Scanning electron microscope observations of sublimates from Merapi Volcano, Indonesia
Symonds, R.
1993-01-01
Sublimates were sampled from high-temperature (up to 800??C) fumaroles at Merapi volcano in January 1984. Sampling is accomplished by inserting silica tubes into high-temperature vents. Volcanic glass flows through the tubes and sublimates precipitate on the inner walls in response to the temperature gradient. With decreasing temperature (800-500??C) in the tubes, there are five sublimate zones. Texturally, the sublimate phases grade from large, well-formed crystals at their highest-temperature occurrence to more numerous, smaller crystals that are less perfect at lower temperatures. These changes imply that the crystal nucleation and growth rates increase and decrease, respectively, as temperature decreases. Overall, the textural data suggest that the gas is saturated or slightly super-saturated with the phases at their hottest occurrence, but that the gas becomes increasingly super-saturated with the phases at lower temperatures. -from Author
Commissaris, R L; Ardayfio, P A; McQueen, D A; Gilchrist, G A; Overstreet, D H
2000-09-01
The high DPAT sensitivity (HDS) and low DPAT sensitivity (LDS) rat lines are the result of selective breeding for differences in the hypothermic response to acute treatment with the 5-HT(1A) receptor agonist 8-hydroxydipropylaminotetralin (8-OHDPAT). The HDS rats exhibit a much greater hypothermic response than do the LDS rats. The present study examined conflict anxiety-like behavior and the effects of acute challenges with 8-OHDPAT and phenobarbital (PhB) on conflict behavior in HDS and LDS rats. Water-restricted (24-h deprivation) HDS and LDS rats were trained to drink from a tube that was occasionally electrified. The 5-s bouts of drinking tube electrification occurred on a fixed interval (FI) 30-s schedule and were signaled by the presence of a tone. Under this schedule, responding is suppressed approximately 10-fold during the tone-on periods compared to the no-tone periods. After two weeks of training in this repeated measures drink suppression conflict paradigm, the effects of acute challenges with 8-OHDPAT (30-500 microg/kg, SC, +10 min) or PhB (20 mg/kg, IP, +10 min) were determined. In control (i.e. , non-drug) conflict test sessions, rats of the HDS line accepted significantly fewer shocks than did rats of the LDS line. Acute treatment with 8-OHDPAT resulted in a modest increase in punished responding (maximum increase: +30-40 shocks/session) in both lines at doses of 60 and 125 microg/kg. Higher doses produced significant general behavioral disruption and substantial reductions in water intake (unpunished responding) in both HDS and LDS rats. Neither the increase in shocks received nor the decrease in water intake produced by these 8-OHDPAT challenges differed between HDS and LDS rats. In both lines, acute PhB treatment resulted in a more dramatic increase in punished responding than did 8-OHDPAT (+55-65 shocks/session) and an increase in water intake. The effects of PhB also did not differ between HDS and LDS rats. These data suggest that the HDS and LDS rats exhibit differences in baseline anxiety-like behavior in the conflict task, but do not differ in their response to acute challenges with PhB or 8-OHDPAT.
Tubing misconnections: normalization of deviance.
Simmons, Debora; Symes, Lene; Guenter, Peggi; Graves, Krisanne
2011-06-01
Accidental connection of an enteral system to an intravenous (IV) system frequently results in the death of the patient. Misconnections are commonly attributed to the presence of universal connectors found in the majority of patient care tubing systems. Universal connectors allow for tubing misconnections between physiologically incompatible systems. The purpose of this review of case studies of tubing misconnections and of current expert recommendations for safe tubing connections was to answer the following questions: In tubing connections that have the potential for misconnections between enteral and IV tubing, what are the threats to safety? What are patient outcomes following misconnections between enteral and IV tubing? What are the current recommendations for preventing misconnections between enteral and IV tubing? Following an extensive literature search and guided by 2 models of threats and errors, the authors analyzed case studies and expert opinions to identify technical, organizational, and human errors; patient-related threats; patient outcomes; and recommendations. A total of 116 case studies were found in 34 publications. Each involved misconnections of tubes carrying feedings, intended for enteral routes, to IV lines. Overwhelmingly, the recommendations were for redesign to eliminate universal connectors and prevent misconnections. Other recommendations were made, but the analysis indicates they would not prevent all misconnections. This review of the published case studies and current expert recommendations supports a redesign of connectors to ensure incompatibility between enteral and IV systems. Despite the cumulative evidence, little progress has been made to safeguard patients from tubing misconnections.
NASA Astrophysics Data System (ADS)
Sadanaga, Yasuhiro; Takaji, Ryo; Ishiyama, Ayana; Nakajima, Kazuo; Matsuki, Atsushi; Bandow, Hiroshi
2016-07-01
A thermal dissociation cavity attenuated phase shift spectroscopy (TD-CAPS) instrument was developed for measuring total peroxy nitrates (PNs) and organic nitrates (ONs) concentrations in the clean atmosphere. This instrument is easy to operate and can be applied to continuous measurement of PNs and ONs. A continuously measurable system is convenient to perform observations, especially in remote areas. Three lines (NO2, PNs, and ONs lines) were used for thermal dissociation. The NO2 line contains a quartz tube that is not heated, while the PN and ON lines contain quartz tubes that are heated at 433 K and 633 K, respectively. The concentrations of NO2, NO2 + PNs, and NO2 + PNs + ONs can be obtained from the NO2, PN, and ON lines, respectively. The lower limit values of the detection limit (3σ) for PNs and ONs were estimated to be 21 parts per trillion by volume with an integration time of 2 min. PNs were selectively thermally decomposed in the PNs line and formed NO2 quantitatively. In the ONs line, both PNs and ONs were thermally decomposed to produce NO2 quantitatively, but partial decomposition of HNO3 at 633 K interfered with the ONs measurement. Therefore, a HNO3 scrubber is required before the ONs line. Continuous observations were conducted with the TD-CAPS instrument in a remote area, and the instrument performed well for obtaining PNs and ONs concentrations.
Warton, Kristina; Yuwono, Nicole L; Cowley, Mark J; McCabe, Mark J; So, Alwin; Ford, Caroline E
2017-10-01
Blood samples for studies of circulating DNA in disease are often collected in clinical settings where prompt processing of samples is not possible. In order to avoid problems associated with leukocyte lysis after prolonged blood storage, stabilised blood tubes have been developed containing preservatives that prevent cell lysis. We evaluated Streck BCT tubes and PAXgene ccfDNA tubes, as well as standard EDTA blood collection tubes, in terms of DNA yield and fragment size. Blood was collected in EDTA, Streck BCT or PAXgene ccfDNA tubes and stored for 1 h at 4 °C, or 4 days at room temperature. DNA was extracted using the QIAamp Circulating Nucleic Acids kit, and visualised on an agarose gel or quantitated by qPCR. Ratios of a 247-base and a 115-base amplicon of the Alu repetitive element were used to infer size distribution. While plasma DNA in EDTA tube blood samples increased by ~10- to 20-fold after 4 days of storage at room temperature, both Streck BCT tubes and PAXgene ccfDNA tubes maintained stable plasma DNA concentrations. A slight decrease in DNA yield following 1 h of blood storage at 4 °C was observed in Streck BCT and PAXgene ccfDNA tubes relative to EDTA tubes. This decrease was reversed by increasing the proteinase digest step of the DNA extraction protocol to 60 min, as recommended by Streck tube product literature. Visualisation of the extracted DNA on an agarose gel showed that after 4 days of room temperature storage, samples collected in EDTA tubes contained abundant high-molecular weight DNA, which was partially fragmented in a ladder pattern. A slight increase in high-molecular weight DNA in samples stored for 4 days at room temperature in Streck BCT tubes was also observed, but this was not reflected in a change in large and small Alu fragment ratios as measured by qPCR. Tubes containing preservative to prevent cell lysis can extend the scope for blood collection in clinical settings; however, slight differences between samples collected in different tube types underscore the requirement for standardised protocols, as well as attention to sample handling.
Material Compatability with Threshold Limit Value Levels of Monomethyl Hydrazine
1988-10-26
supply was house- compressed air conditioned by passing through a series of demisters, a hot Hopcalite catalyst bed, a reciprocating dual-tower...recorded. At the end of a test, the tubing was rinsed with methanol and dried with compressed breathing air . Cleaning the tubing material between tests had...niecessary and identify by block wbr -’Materials were evaluated for potential use as ambient air sample lines for hydrazines. Fluorinated poly- mers
Fireproof Hydraulic Brake System.
1985-10-01
MLBT elastomer personnel recommended the use of Firestone’s Phosphonitrilic Fluoroelastomer (PNF) for elastomeric O-rings in the CTFE fluid system. C.E...resealed with modified "PNF" (phosphonitrilic fluoroelastomer) elastomer Ŕ" rings. The hoses are PTFE lined for compatibility with the CTFE...Plus 65-42808-6 Nylon Braid )* AN837-8 Elbow (on Truck) 61-11536-1 Tube Assy (Strut/Truck Hose to Truck Tee)* 290 -7. 61-11530-1 Tube Assy (Truck Tee
Evaluation of DCS III Transmission Alternatives. Phase 1A Report.
1980-05-26
to be used to construct the waveguide. Most commonly used measures are straight and precision tubing, dielectric lining, and helix construction. These...controlled L5E. 3-11 The broadband signal, either analog or digital, can be transmitted over a coaxial cable. Although economic reasons as well as high...or another with power capability ranging from milliwatts up to several hundred kilowatts. One kind of mm source is travelling wave tubes ( TWT ) which
Decreasing radiation exposure on pediatric portable chest radiographs.
Hawking, Nancy G; Sharp, Ted D
2013-01-01
To determine whether additional shielding designed for pediatric patients during portable chest exams that ascertain endotracheal tube placement would significantly decrease the amount of scatter radiation. Children aged 24 months or younger were intubated and received daily morning chest radiographs to determine endotracheal tube placement. For each measurement, the amount of scatter radiation decreased by more than 20% from a nonshielded exposure to a shielded exposure. There was a significant decrease in scatter radiation when using the lead shielding device along with appropriate collimation vs appropriate collimation alone. These results suggest that applying additional shielding to appropriately collimated chest radiographs could significantly reduce scatter radiation and therefore the overall dose to young children.
Ueshima, Chiyuki; Kataoka, Tatsuki R; Hirata, Masahiro; Sugimoto, Akihiko; Iemura, Yoshiki; Minamiguchi, Sachiko; Nomura, Takashi; Haga, Hironori
2018-06-01
The involvement of mast cells in the establishment of pregnancy is unclear. Herein, we found that human mast cells are present in the decidual tissues of parous women and expressed a human-specific protein killer cell Ig-like receptor (KIR) 2DL4, a receptor for human leukocyte antigen G expressed on human trophoblasts. In contrast, decreased numbers of decidual mast cells and reduced KIR2DL4 expression were observed in these cells of infertile women who had undergone long-term corticosteroid treatment. Co-culture of the human mast cell line, LAD2, and human trophoblast cell line, HTR-8/SVneo, accelerated the migration and tube formation of HTR-8/SVneo cells in a KIR2DL4-dependent manner. These observations suggest the possible involvement of human mast cells in the establishment of pregnancy via KIR2DL4 and that long-term corticosteroid treatment may cause infertility by influencing the phenotypes of decidual mast cells. Copyright © 2018 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Concept of modernization of input device of oil and gas separator
NASA Astrophysics Data System (ADS)
Feodorov, A. B.; Afanasov, V. I.; Miroshnikov, R. S.; Bogachev, V. V.
2017-10-01
The process of defoaming in oil production is discussed. This technology is important in oil and gas fields. Today, the technology of separating the gas fraction is based on chemical catalysis. The use of mechanical technologies improves the economics of the process. Modernization of the separator input device is based on the use of long thin tubes. The chosen length of the tubes is two orders of magnitude larger than the diameter. The separation problem is solved by creating a high centrifugal acceleration. The tubes of the input device are connected in parallel and divide the input stream into several arms. The separated fluid flows are directed tangentially into the working tubes to create a vortex motion. The number of tubes connected in parallel is calculated in accordance with the flow rate of the fluid. The connection of the working tubes to the supply line is made in the form of a flange. This connection allows carrying out maintenance without stopping the flow of fluid. An important feature of this device is its high potential for further modernization. It is concerned with the determination of the parameters of the tubes and the connection geometry in the construction of a single product.
The role of retinoic acid in the morphogenesis of the neural tube.
Wilson, L; Gale, E; Maden, M
2003-10-01
We have examined the role of the signalling molecule, retinoic acid, in the process of neurulation and the subsequent growth and differentiation of the central nervous system using quail embryos that have developed in the absence of retinoic acid. Such retinoic acid-free embryos undergo abnormal neural tube formation in terms of its shape and structure, but the embryos do not display spina bifida or exencephaly. The neural tubes have a wider floor plate, a thicker roof plate and a different dorsoventral shape. Phalloidin staining and electron microscopy revealed alterations in the actin filaments and the junctional complexes of the cell layer lining the lumen. Initially the neural tubes proliferated at the same rate as normal, but later the proliferation rate declined drastically and neuronal differentiation was highly deficient. There were very few motoneurons extending neurites into the periphery, and within the neural tube axon trajectories were chaotic. These results reveal several functions for retinoic acid in the morphogenesis and growth of the neural tube, many of which can be explained by defective notochord signalling, but they do not suggest that this molecule plays a role in neural tube closure.
Assessment of a low-cost, point-of-use, ultraviolet water disinfection technology.
Brownell, Sarah A; Chakrabarti, Alicia R; Kaser, Forest M; Connelly, Lloyd G; Peletz, Rachel L; Reygadas, Fermin; Lang, Micah J; Kammen, Daniel M; Nelson, Kara L
2008-03-01
We describe a point-of-use (POU) ultraviolet (UV) disinfection technology, the UV Tube, which can be made with locally available resources around the world for under $50 US. Laboratory and field studies were conducted to characterize the UV Tube's performance when treating a flowrate of 5 L/min. Based on biological assays with MS2 coliphage, the UV Tube delivered an average fluence of 900+/-80 J/m(2) (95% CI) in water with an absorption coefficient of 0.01 cm(-1). The residence time distribution in the UV Tube was characterized as plug flow with dispersion (Peclet Number = 19.7) and a mean hydraulic residence time of 36 s. Undesirable compounds were leached or produced from UV Tubes constructed with unlined ABS, PVC, or a galvanized steel liner. Lining the PVC pipe with stainless steel, however, prevented production of regulated halogenated organics. A small field study in two rural communities in Baja California Sur demonstrated that the UV Tube reduced E. coli concentrations to less than 1/100 ml in 65 out of 70 samples. Based on these results, we conclude that the UV Tube is a promising technology for treating household drinking water at the point of use.
Heat conduction in double-walled carbon nanotubes with intertube additional carbon atoms.
Cui, Liu; Feng, Yanhui; Tan, Peng; Zhang, Xinxin
2015-07-07
Heat conduction of double-walled carbon nanotubes (DWCNTs) with intertube additional carbon atoms was investigated for the first time using a molecular dynamics method. By analyzing the phonon vibrational density of states (VDOS), we revealed that the intertube additional atoms weak the heat conduction along the tube axis. Moreover, the phonon participation ratio (PR) demonstrates that the heat transfer in DWCNTs is dominated by low frequency modes. The added atoms cause the mode weight factor (MWF) of the outer tube to decrease and that of the inner tube to increase, which implies a lower thermal conductivity. The effects of temperature, tube length, and the number and distribution of added atoms were studied. Furthermore, an orthogonal array testing strategy was designed to identify the most important structural factor. It is indicated that the tendencies of thermal conductivity of DWCNTs with added atoms change with temperature and length are similar to bare ones. In addition, thermal conductivity decreases with the increasing number of added atoms, more evidently for atom addition concentrated at some cross-sections rather than uniform addition along the tube length. Simultaneously, the number of added atoms at each cross-section has a considerably more remarkable impact, compared to the tube length and the density of chosen cross-sections to add atoms.
The effect of tubing dwell time on insulin adsorption during intravenous insulin infusions.
Thompson, Cecilia D; Vital-Carona, Jessica; Faustino, E Vincent S
2012-10-01
Insulin adsorbs to plastic tubing, which decreases the concentration of an insulin solution delivered from an intravenous infusion set. Dwelling insulin within tubing before starting the infusion decreases adsorption but delays treatment initiation and wastes time in infusion preparation. The lack of data on dwell time effects results in wide variability in practice. We aim to determine the effect of dwell time on insulin concentration from intravenous infusion tubing. In this in vitro study, we used insulin solutions with concentrations of 0.1 unit/mL, 1 unit/mL, and 10 units/mL. Each solution dwelled in intravenous infusion sets for 0, 15, 30, or 60 min. After the dwell, we measured insulin concentrations from the solution bags and tubing. We repeated each insulin concentration-dwell time combination five times. Comparisons were performed using analyses of variance. For each of the three insulin concentrations, the mean insulin concentrations from the tubing were not significantly different between dwell times. Duration of dwell time did not affect insulin adsorption in polypropylene intravenous infusion sets. We recommend that following a 20-mL flush, insulin infusions can be started without any dwell time. Removal of dwell times may improve clinical practice by minimizing preparation time and will allow faster initiation of insulin infusion therapy.
Kiba, Nobutoshi; Ito, Seiji; Tachibana, Masaki; Tani, Kazue; Koizumi, Hitoshi
2003-12-01
A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d., 75 cm) and the tube was placed in front of a photomultipier tube as a flow cell. Two-peak response was obtained by one injection of the sample solution. The first and second peaks were dependent on the concentrations of Ch and ACh, respectively. The influence of some experimental parameters such as flow rate, amounts of immobilized enzymes on the behavior of the sensor was studied in order to optimize the sensitivity, sample throughput and resolution. Calibration curves were linear at 1 - 1000 nM for Ch and 3 - 3000 nM for ACh. The sample throughput was 25/h without carryover. The FI system was applied to the simultaneous determination of Ch and ACh in rabbit brain tissue homogenates.
Harris, William G.
1985-01-01
A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.
Buise, Marc P; Ince, Can; Tilanus, Hugo W; Klein, Jan; Gommers, Diederik; van Bommel, Jasper
2005-04-01
Esophagectomy followed by gastric tube reconstruction is the surgical treatment of choice for patients with esophageal cancer. Complications of the cervical anastomosis are associated with impaired microvascular blood flow (MBF) and ischemia in the gastric fundus. The aim of the present study was to differentiate whether the decrease in MBF is a result of arterial insufficiency or of venous congestion. To do this we assessed MBF, microvascular hemoglobin oxygen saturation (muHbSo(2)), and microvascular hemoglobin concentration (muHbcon) simultaneously during different stages of gastric tube reconstruction. In 14 patients, MBF was determined with laser Doppler flowmetry, and muHbSo(2) and muHbcon were determined with reflectance spectro- photometry. After completion of the anastomosis, nitroglycerin was applied at the fundus. Although MBF did not change significantly in the pylorus, MBF decreased progressively during surgery in the fundus from 210 +/- 18 Arbitrary Units at baseline (normal stomach) to 52 +/- 9 Arbitrary Units after completion of reconstruction (mean +/- sem; P < 0.05). There was no change in muHbSo(2) and muHbcon during the reconstruction. After application of nitroglycerin, MBF doubled. We conclude that MBF decreases during gastric tube reconstruction but that muHbSo(2) and muHbcon do not. This decrease might be the result of venous congestion, which can partly be counteracted by application of nitroglycerin.
NASA Astrophysics Data System (ADS)
Pech-Canul, M. A.; Guía-Tello, J. C.; Pech-Canul, M. I.; Aguilar, J. C.; Gorocica-Díaz, J. A.; Arana-Guillén, R.; Puch-Bleis, J.
An aluminum automotive condenser was designed to exhibit high corrosion resistance in the seawater acetic acid test (SWAAT) combining zinc coated microchannel tubes and fins made with AA4343/AA3003(Zn)/AA4343 brazing sheet. Electrochemical measurements in SWAAT solution were carried out under laboratory conditions using tube-fin assembly and individual fin and tube samples withdrawn from the condenser core. The aim was to gain information on the protective role of the zinc sacrificial layer and about changes in corrosion behavior as a function of immersion time. External corrosion of the tube-fin system was simulated by immersion of mini-core samples under open circuit conditions. The corrosion rate increased rapidly during the first 6 h and slowly afterwards. The short time behavior was related to the dissolution of the oxide film and fast dissolution of the outermost part of the zinc diffusion layer. With the aid of cross-sectional depth corrosion potential profiles, it was shown that as the sacrificial layer gets dissolved, the surface concentration of zinc decreases and the potential shifts to less negative values. The results of galvanic coupling of tube and fins in a mini-cell showed that the tube became the anode while the fins exhibited cathodic behavior. An evolution in the galvanic interaction was observed, due to the progressive dissolution of the sacrificial zinc layer. The difference of uncoupled potentials between tube and fins decreased from 71 mV to 32 mV after 84 h of galvanic coupling. At the end of such period there was still a part of the zinc sacrificial layer remaining which would serve for protection of the tube material for even longer periods and there were indications of slight corrosion in the fins.
Bourdeaux, Daniel; Sautou-Miranda, Valérie; Bagel-Boithias, Sandrine; Boyer, Anne; Chopineau, Jean
2004-04-01
Di(2-ethylhexyl)phthalate (DEHP), a plasticiser present in infusion equipment, is known to be harmful to human health. Various studies have shown that DEHP is released into drug solutions from polyvinyl chloride (PVC) infusion lines. New multi-layer tubing has therefore been marketed to overcome this problem. We assessed the inertness of this tubing when placed in contact with a solution of CELLTOP. Chromatographic assay of DEHP showed no significant difference in DEHP levels in the solution when placed in contact with PVC and with multi-layer tubing. Analysis by infrared spectrometry showed that DEHP was initially present in the polyethylene layer of the multi-layer tubing even before contact with the drug solution. Contact with the solution results in release of DEHP from the container into the contents. The substance responsible for this release is in fact an excipient of CELLTOP, polysorbate. This release of DEHP further proves to depend on parameters such as temperature, time of contact between solution and tubing, and the concentration of polysorbate in the infused drug solution.
Heating rates in furnace atomic absorption using the L'vov platform
Koirtyohann, S.R.; Giddings, R.C.; Taylor, Howard E.
1984-01-01
Heating rate profiles for the furnace tube wall, the furnace atmosphere, and a L'vov platform were established for a range of conditions in a cyclically heated graphite atomizer. The tube wall profile was made by direct observation with a recording optical pyrometer. The sodium line reversal method was used to establish the heating rate of the furnace atmosphere, and appearance temperatures for a series metals of differing volatility was used to establish platform profiles. The tube wall heating rate was nearly linear at 2240??C s- until the desired temperature was reached after which the temperature remained constant. The furnace atmosphere reached a given temperature 0.2-0.4 s later than the tube wall through most of the atomize cycle. The platform lagged the tube wall 0.5-0.8 s. Under typical operating conditions the furnace atmosphere was 100-200??C cooler than the tube wall and at nearly constant temperature when the analyte vaporized from the platform. The L'vov platform causes the cyclically heated commercial furnace to approximate the behavior of a constant temperature furnace during atomization. ?? 1984.
Yang, Hee-Jin; Wang, Kyu-Chang; Chi, Je G; Lee, Myung-Sook; Lee, Yun-Jin; Kim, Seung-Ki; Cho, Byung-Kyu
2003-04-14
In an attempt to understand the events in the secondary neurulation in embryonic stage, we investigated morphological changes in the tail bud of normal developing chick embryos. Hamburger and Hamilton stage 16-45 embryos were harvested and processed for light microscopic studies. The secondary neural tube is formed by aggregation of the caudal cell mass. Cells are arranged into a cord-like mass (medullary cord), which is continuous with the primary neural tube. Multiple small cavities develop in the medullary cord, and these cavities coalesce into one single lumen. The process of coalescence is completed by stage 35, and the whole neural tube is transformed into one tube with a single continuous lumen. At this stage, the terminal portion of the neural tube is bulged dorsally. Thereafter, the caudal portion of the neural tube regresses, and the proximal portion develops into normal spinal cord. Transient occlusion of the central canal was observed at stage 40 in one sample. The sequence of events elucidated in this study can be used as base-line data for experiments concerning congenital malformations involving secondary neurulation.
Tethered nuclear power for the Space Station
NASA Technical Reports Server (NTRS)
Bents, D. J.
1985-01-01
A nuclear space power system the SP-100 is being developed for future missions where large amounts of electrical power will be required. Although it is primarily intended for unmanned spacecraft, it can be adapted to a manned space platform by tethering it above the station through an electrical transmission line which isolates the reactor far away from the inhabited platform and conveys its power back to where it is needed. The transmission line, used in conjunction with an instrument rate shield, attenuates reactor radiation in the vicinity of the space station to less than one-one hundredth of the natural background which is already there. This combination of shielding and distance attenuation is less than one-tenth the mass of boom-mounted or onboard man-rated shields that are required when the reactor is mounted nearby. This paper describes how connection is made to the platform (configuration, operational requirements) and introduces a new element the coaxial transmission tube which enables efficient transmission of electrical power through long tethers in space. Design methodology for transmission tubes and tube arrays is discussed. An example conceptual design is presented that shows SP-100 at three power levels 100 kWe, 300 kWe, and 1000 kWe connected to space station via a 2 km HVDC transmission line/tether. Power system performance, mass, and radiation hazard are estimated with impacts on space station architecture and operation.
Tethered nuclear power for the space station
NASA Technical Reports Server (NTRS)
Bents, D. J.
1985-01-01
A nuclear space power system the SP-100 is being developed for future missions where large amounts of electrical power will be required. Although it is primarily intended for unmanned spacecraft, it can be adapted to a manned space platform by tethering it above the station through an electrical transmission line which isolates the reactor far away from the inhabited platform and conveys its power back to where it is needed. The transmission line, used in conjunction with an instrument rate shield, attenuates reactor radiation in the vicinity of the space station to less than one-one hundredth of the natural background which is already there. This combination of shielding and distance attenuation is less than one-tenth the mass of boom-mounted or onboard man-rated shields that are required when the reactor is mounted nearby. This paper describes how connection is made to the platform (configuration, operational requirements) and introduces a new element the coaxial transmission tube which enables efficient transmission of electrical power through long tethers in space. Design methodology for transmission tubes and tube arrays is discussed. An example conceptual design is presented that shows SP-100 at three power levels 100 kWe, 300 kWe, and 1000 kWe connected to space station via a 2 km HVDC transmission line/tether. Power system performance, mass, and radiation hazard are estimated with impacts on space station architecture and operation.
NASA Technical Reports Server (NTRS)
Taleghani, Barmac K.; Pappa, Richard S.
1996-01-01
Structural materials in the form of graphite epoxy composites with embedded rubber layers are being used to reduce vibrations in rocket motor tubes. Four filament-wound, graphite epoxy tubes were studied to evaluate the effects of the rubber layer on the modal parameters (natural vibration frequencies, damping, and mode shapes). Tube 1 contained six alternating layers of 30-degree helical wraps and 90-degree hoop wraps. Tube 2 was identical to tube 1 with the addition of an embedded 0.030-inch-thick rubber layer. Tubes 3 and 4 were identical to tubes 1 and 2, respectively, with the addition of a Textron Kelpoxy elastomer. This report compares experimental modal parameters obtained by impact testing with analytical modal parameters obtained by NASTRAN finite-element analysis. Four test modes of tube 1 and five test modes of tube 3 correlate highly with corresponding analytical predictions. Unsatisfactory correlation of test and analysis results occurred for tubes 2 and 4 and these comparisons are not shown. Work is underway to improve the analytical models of these tubes. Test results clearly show that the embedded rubber layers significantly increase structural modal damping as well as decrease natural vibration frequencies.
A novel investigation of heat transfer characteristics in rifled tubes
NASA Astrophysics Data System (ADS)
Jegan, C. Dhayananth; Azhagesan, N.
2018-05-01
The experimental investigation of heat transfer of water flowing in a rifled tube was explored at different pressures and at various operating conditions in a rifled tube heat exchanger. The specifications for the inner and outer diameters of the inner tube are 25.8 and 50.6 mm, respectively. The working fluids used in shell side and tube side are cold and hot water. The rifled tube was made of the stainless steel with 4 ribs, 50.6 mm outer diameter, 0.775 mm rib height, 58o helix angle and the length 1500 mm. The effect of pressure, wall heat flux and friction factor were discussed. The results confirm that even at low pressures the rifled tubes has an obvious enhancement in heat transfer compared with smooth tube. Results depicts that the Nusselt number increases with Reynolds number and the friction factor decreases with increase in Reynolds number and the heat transfer rate is higher for the rifled tube when compared to smooth tube, because of strong swirl flow due to centrifugal action. It also confirms that, the friction factor obtained from the rifled tube is significantly higher than that of smooth tube.
Energy Absorption of Expansion Tube Considering Local Buckling Characteristics
NASA Astrophysics Data System (ADS)
Ahn, Kwang-Hyun; Kim, Jin-Sung; Huh, Hoon
This paper deals with the crash energy absorption and the local buckling characteristics of the expansion tube during the tube expanding processes. In order to improve energy absorption capacity of expansion tubes, local buckling characteristics of an expansion tube must be considered. The local buckling load and the absorbed energy during the expanding process were calculated for various types of tubes and punch shapes with finite element analysis. The energy absorption capacity of the expansion tube is influenced by the tube and the punch shape. The material properties of tubes are also important parameter for energy absorption. During the expanding process, local buckling occurs in some cases, which causes significant decreasing the absorbed energy of the expansion tube. Therefore, it is important to predict the local buckling load accurately to improve the energy absorption capacity of the expansion tube. Local buckling takes place relatively easily at the large punch angle and expansion ratio. Local buckling load is also influenced by both the tube radius and the thickness. In prediction of the local buckling load, modified Plantema equation was used for strain hardening and strain rate hardening. The modified Plantema equation shows a good agreement with the numerical result.
Sea urchin tube feet are photosensory organs that express a rhabdomeric-like opsin and PAX6
Lesser, Michael P.; Carleton, Karen L.; Böttger, Stefanie A.; Barry, Thomas M.; Walker, Charles W.
2011-01-01
All echinoderms have unique hydraulic structures called tube feet, known for their roles in light sensitivity, respiration, chemoreception and locomotion. In the green sea urchin, the most distal portion of these tube feet contain five ossicles arranged as a light collector with its concave surface facing towards the ambient light. These ossicles are perforated and lined with pigment cells that express a PAX6 protein that is universally involved in the development of eyes and sensory organs in other bilaterians. Polymerase chain reaction (PCR)-based sequencing and real time quantitative PCR (qPCR) also demonstrate the presence and differential expression of a rhabdomeric-like opsin within these tube feet. Morphologically, nerves that could serve to transmit information to the test innervate the tube feet, and the differential expression of opsin transcripts in the tube feet is inversely, and significantly, related to the amount of light that tube feet are exposed to depending on their location on the test. The expression of these genes, the differential expression of opsin based on light exposure and the unique morphological features at the distal portion of the tube foot strongly support the hypothesis that in addition to previously identified functional roles of tube feet they are also photosensory organs that detect and respond to changes in the underwater light field. PMID:21450733
Sampling Artifacts from Conductive Silicone Tubing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Timko, Michael T.; Yu, Zhenhong; Kroll, Jesse
2009-05-15
We report evidence that carbon impregnated conductive silicone tubing used in aerosol sampling systems can introduce two types of experimental artifacts: 1) silicon tubing dynamically absorbs carbon dioxide gas, requiring greater than 5 minutes to reach equilibrium and 2) silicone tubing emits organic contaminants containing siloxane that adsorb onto particles traveling through it and onto downstream quartz fiber filters. The consequence can be substantial for engine exhaust measurements as both artifacts directly impact calculations of particulate mass-based emission indices. The emission of contaminants from the silicone tubing can result in overestimation of organic particle mass concentrations based on real-time aerosolmore » mass spectrometry and the off-line thermal analysis of quartz filters. The adsorption of siloxane contaminants can affect the surface properties of aerosol particles; we observed a marked reduction in the water-affinity of soot particles passed through conductive silicone tubing. These combined observations suggest that the silicone tubing artifacts may have wide consequence for the aerosol community and should, therefore, be used with caution. Gentle heating, physical and chemical properties of the particle carriers, exposure to solvents, and tubing age may influence siloxane uptake. The amount of contamination is expected to increase as the tubing surface area increases and as the particle surface area increases. The effect is observed at ambient temperature and enhanced by mild heating (<100 oC). Further evaluation is warranted.« less
May, T.W.; Wiedmeyer, Ray H.
1998-01-01
The CETAC ADX-500 autodiluter system was tested with ELAN?? v 2.1 software and the ELAN 6000 ICP-MS instrument to determine on-line automated dilution performance during analysis of standard solutions containing nine analytes representative of the mass spectral range (mass 9 to mass 238). Two or more dilution schemes were tested for each of 5 test tube designs. Dilution performance was determined by comparison of analyte concentration means of diluted and non-diluted standards. Accurate dilutions resulted with one syringe pump addition of diluent in small diameter round-bottomed (13 mm OD) or conical-tipped (18 mm OD) tubes and one or more syringe pump additions in large diameter (28 mm OD) conical-tipped tubes. Inadequate dilution mixing which produced high analyte concentration means was observed for all dilutions conducted in flat-bottomed tubes, and for dilutions requiring multiple syringe additions of diluent in small diameter round-bottomed and conical tipped tubes. Effective mixing of diluted solutions was found to depend largely upon tube diameter and liquid depth: smaller tube diameters and greater liquid depth resulted in ineffective mixing, whereas greater tube diameter and shallower liquid depth facilitated effective mixing. Two design changes for the autodiluter were suggested that would allow effective mixing to occur using any dilution scheme and tube design.
NASA Astrophysics Data System (ADS)
Yao, Shunchun; Xu, Jialong; Dong, Xuan; Zhang, Bo; Zheng, Jianping; Lu, Jidong
2015-08-01
The on-line measurement of coal is extremely useful for emission control and combustion process optimization in coal-fired plant. Laser-induced breakdown spectroscopy was employed to directly analyze coal particle flow. A set of tapered tubes were proposed for beam-focusing the coal particle flow to different diameters. For optimizing the measurement of coal particle flow, the characteristics of laser-induced plasma, including optical breakdown, the relative standard deviation of repeated measurement, partial breakdown spectra ratio and line intensity, were carefully analyzed. The comparison of the plasma characteristics among coal particle flow with different diameters showed that air breakdown and the random change in plasma position relative to the collection optics could significantly influence on the line intensity and the reproducibility of measurement. It is demonstrated that the tapered tube with a diameter of 5.5 mm was particularly useful to enrich the coal particles in laser focus spot as well as to reduce the influence of air breakdown and random changes of plasma in the experiment.
Investigation of the tone-burst tube for duct lining attenuation measurement
NASA Technical Reports Server (NTRS)
Soffel, A. R.; Morrow, P. F.
1972-01-01
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
Effect of oxide films on hydrogen permeability of candidate Stirling engine heater head tube alloys
NASA Technical Reports Server (NTRS)
Schuon, S. R.; Misencik, J. A.
1981-01-01
The effect of oxide films developed in situ from CO/CO2 doped hydrogen on high pressure hydrogen permeability at 820 C was studied on N-155, A-286, IN 800, 19-9DL, Nitronic 40, HS-188, and IN 718 tubing in a Stirling materials simulator. The hydrogen permeability decreased with increasing dopant levels of CO or CO2 and corresponding decreases in oxide porosity. Minor reactive alloying elements strongly influenced permeability. At high levels of CO or CO2, a liquid oxide formed on alloys with greater than 50 percent Fe. This caused increased permeability. The oxides formed on the inside tube walls were analyzed and their effective permeabilities were calculated.
Anti-angiogenic and cytotoxicity studies of some medicinal plants.
Ng, Kwok-Wen; Salhimi, Salizawati Muhamad; Majid, Amin Malik; Chan, Kit-Lam
2010-06-01
Angiogenesis plays an important role in tumor formation and proliferation. The development of anti-angiogenic agents to block new blood vessel growth will inhibit metastasis and induce apoptosis of the cancer cells. Nine medicinal plants, Strobilanthes crispus, Phyllanthus niruri, Phyllanthus pulcher, Phyllanthus urinaria, Ailanthus malabarica, Irvingia malayana, Smilax myosotiflora, Tinospora crispa and blumea balsamifera were screened for anti-angiogenic properties using the rat aortic ring assay. Of these, the methanol extracts of Phyllanthus species and Irvingia malayana exhibited the highest activity. At 100 microg/mL, P. pulcher, P. niruri, P. urinaria and I. malayana recorded an inhibition of 78.8 %, 59.5 %, 56.7 % and 46.4 %, respectively, against rat aortic vascular growth. Their activities were further investigated by the tube formation assay involving human umbilical vein endothelial cells (HUVEC) on Matrigel. I. malayana, P. niruri and P. urinaria showed a significant decrease of 45.5, 37.9 and 35.6 %, respectively, whilst P. pulcher showed a much lower decrease of 15.5 % when compared with that of the rat aortic ring assay. All the plant extracts were evaluated for cytotoxicity on a panel of human cancer cell lines using the MTT assay. None of them displayed acute cytotoxicity. The HPLC of P. niruri, P. urinaria and P. pulcher indicated the extracts contained some identical chromatographic peaks of lignans. Further fractionation of I. malayana yielded betulinic acid reported in this plant for the first time and at 100 microg/mL it exhibited a 67.3 % inhibition of vessel outgrowth and 46.5 % inhibition of tube formation. Georg Thieme Verlag KG Stuttgart-New York.
NASA Astrophysics Data System (ADS)
Abdelatief, Mohamed A.; Sayed Ahmed, Sayed Ahmed E.; Mesalhy, Osama M.
2018-03-01
The present work evaluates, experimentally and numerically, by the aid of commercial code FLUENT 6.3.26, the effects of relative locations (ΔX or ΔY), heights (hw), and span-angle (θ) of winglet-vortex-generators (WVGs) on thermal-hydraulic performance enhancement for down-stream and/or up-stream wing-shaped-tubes bundle heat exchangers for air Re ranging from 1.85 × 103 to 9.7 × 103 while water Re = 5 × 102. hw is set as 5 mm, 7.5 mm and 10 mm. For tube down-stream, θ is set as 0° (Base-line-case) and from 5° to 45° clockwise common-flow up (CFUp) and counterclockwise common-flow down (CFDn) while for tube up-stream it is set as -5°, -10° and -15° CFUp. Results show that the increase of θ counterclockwise-(CFDn) or clockwise-(CFUp) leads to increase the values of Nu number. Using WVGs with (+5 ° ≤ θ ≤ +45°) results in increasing Nu number by about from 34 to 48% comparing with that of base-line-case. The lowest values of drag coefficient ( f) for tube down-stream are obtained at +5° CFDn and -15° CFUp with respect to the base-line case. For tube up-stream, Nu number increases by increasing θ from 0° to -5° and the values of Nu number for θ varying from -5° to -15° have no significant changes. ( f) increases with hw and has negligible effect on ha. Furthermore, optimization analyses of θ and longitudinal fin (LF) are utilized, in four cases, for finding the optimum combination and maximum efficiency. The highest values of heat transfer parameters such as effectiveness (ɛ), area goodness factor (G) and efficiency index (η) and the lowest values of fluid-flow parameters like ( f) and hence the best efficiency, are achieved for -15° CFUp down-stream, ("case 3" of -15° CFUp down-stream and 6 mm LF height) and +5° CFDn down-stream. Correlations of Nu number, ( f) and (ɛ) as a function of θ and Re for the studied cases are performed.
Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... of cancer, including ovarian cancer, or other conditions. Studies have also shown that ... Screening tests have risks. The risks of ovarian, fallopian tube, ...
NASA Technical Reports Server (NTRS)
Curry, Robert E.; Gilyard, Glenn B.
1989-01-01
A flight experiment was conducted to evaluate a pressure measurement system which uses pneumatic tubing and remotely located electronically scanned pressure transducer modules for in-flight unsteady aerodynamic studies. A parametric study of tubing length and diameter on the attenuation and lag of the measured signals was conducted. The hardware was found to operate satisfactorily at rates of up to 500 samples/sec per port in flight. The signal attenuation and lag due to tubing were shown to increase with tubing length, decrease with tubing diameter, and increase with altitude over the ranges tested. Measurable signal levels were obtained for even the longest tubing length tested, 4 ft, at frequencies up to 100 Hz. This instrumentation system approach provides a practical means of conducting detailed unsteady pressure surveys in flight.
BOILING WATER REACTOR WITH FEED WATER INJECTION NOZZLES
Treshow, M.
1963-04-30
This patent covers the use of injection nozzles for pumping water into the lower ends of reactor fuel tubes in which water is converted directly to steam. Pumping water through fuel tubes of this type of boiling water reactor increases its power. The injection nozzles decrease the size of pump needed, because the pump handles only the water going through the nozzles, additional water being sucked into the tubes by the nozzles independently of the pump from the exterior body of water in which the fuel tubes are immersed. The resulting movement of exterior water along the tubes holds down steam formation, and thus maintains the moderator effectiveness, of the exterior body of water. (AEC)
Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.
Luo, Jie; Porteous, Nuala; Sun, Yuyu
2011-08-01
A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 in., or 1.6 mm) to diffuse DCP into the tubing's inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications.
Challenges in contrast-enhanced spectral mammography interpretation: artefacts lexicon.
Yagil, Y; Shalmon, A; Rundstein, A; Servadio, Y; Halshtok, O; Gotlieb, M; Sklair-Levy, M
2016-05-01
To review and describe commonly encountered artefacts in contrast-enhanced spectral mammography (CESM). This retrospective study included 200 women who underwent CESM examinations for screening and diagnostic purposes. Analysis was performed on the image data sets of these women, comprising of a total of 774 subtracted images. Images were reviewed with focus on the presence of four artefacts: rim ("breast within breast"), ripple (black and white lines), axillary line, and skin-line enhancement (skin-line highlighting). Statistical cross-correlation and association with acquisition parameters (tube current, tube voltage, compression force, breast thickness, paddle size) was compared using Fisher's exact test and t-test. The rim artefact was highly common (97-99%) in every projection. The ripple artefact was increasingly more common on the oblique projections (80-82%) and found to be associated with higher breast thickness values. The axillary line artefact was detected only on oblique projections (63%) and associated with the use of a small compression paddle. The skin-line enhancement artefact was seen in 19-46% of projections. None of the artefacts interfered with image interpretation. Two main artefacts commonly seen on CESM are rim and ripple artefacts. They do not hamper with image interpretation. It is important to be aware of them and prevent misinterpretation of these artefacts as real breast pathology. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Simulation studies on Tube End Expansion of AA2014 Alloy Tubes
NASA Astrophysics Data System (ADS)
Venugopal, L.; Prasad, N. E. C.; Geeta Krishna, P.; Praveen, L.
2018-03-01
End forming is defined as forming the end of tubular forms either by inverting the tube or by expanding it. It finds application in many fields such as in automotive and aerospace sectors as power transmission elements, fuel lines, exhaust pipes etc. The main aim of the present work is to expand the AA2014 alloy tubes with different die sets without any fracture. Deform 2D software was used for performing simulations on expanding the tubes with different die set (punch) values having differed forming angles (α = 15°, 30° and 45°) and expansion ratios (rp/r0 = 1.39, 1.53 and 1.67). Experiments were also conducted and the results correlate with the simulation results. The results shows that for the punch having less cone angle (α) values the linear displacement is more rather than higher cone angles. But in the case of higher cone angles the radial displacement is more than the linear displacement.
... of placement carefully with your physician and surgeon. Methods of Feeding Enteral feeding means the gastrointestinal (digestive) ... unable to absorb nutrients from enteral feeds. This method of feeding requires a central intravenous line. A ...
absorption sensor for sensitive temperature and species measurements in high-temperature gases
NASA Astrophysics Data System (ADS)
Spearrin, R. M.; Ren, W.; Jeffries, J. B.; Hanson, R. K.
2014-09-01
A continuous-wave laser absorption diagnostic, based on the infrared CO2 bands near 4.2 and 2.7 μm, was developed for sensitive temperature and concentration measurements in high-temperature gas systems using fixed-wavelength methods. Transitions in the respective R-branches of both the fundamental υ 3 band (~2,350 cm-1) and combination υ 1 + υ 3 band (~3,610 cm-1) were chosen based on absorption line-strength, spectral isolation, and temperature sensitivity. The R(76) line near 2,390.52 cm-1 was selected for sensitive CO2 concentration measurements, and a detection limit of <5 ppm was achieved in shock tube kinetics experiments (~1,300 K). A cross-band, two-line thermometry technique was also established utilizing the R(96) line near 2,395.14 cm-1, paired with the R(28) line near 3,633.08 cm-1. This combination yields high temperature sensitivity (ΔE" = 3,305 cm-1) and expanded range compared with previous intra-band CO2 sensors. Thermometry performance was validated in a shock tube over a range of temperatures (600-1,800 K) important for combustion. Measured temperature accuracy was demonstrated to be better than 1 % over the entire range of conditions, with a standard error of ~0.5 % and µs temporal resolution.
Jang, Cheongjae; Ha, Junhyoung; Dupont, Pierre E.; Park, Frank Chongwoo
2017-01-01
Although existing mechanics-based models of concentric tube robots have been experimentally demonstrated to approximate the actual kinematics, determining accurate estimates of model parameters remains difficult due to the complex relationship between the parameters and available measurements. Further, because the mechanics-based models neglect some phenomena like friction, nonlinear elasticity, and cross section deformation, it is also not clear if model error is due to model simplification or to parameter estimation errors. The parameters of the superelastic materials used in these robots can be slowly time-varying, necessitating periodic re-estimation. This paper proposes a method for estimating the mechanics-based model parameters using an extended Kalman filter as a step toward on-line parameter estimation. Our methodology is validated through both simulation and experiments. PMID:28717554
Dynamics of explosively imploded pressurized tubes
NASA Astrophysics Data System (ADS)
Szirti, Daniel; Loiseau, Jason; Higgins, Andrew; Tanguay, Vincent
2011-04-01
The detonation of an explosive layer surrounding a pressurized thin-walled tube causes the formation of a virtual piston that drives a precursor shock wave ahead of the detonation, generating very high temperatures and pressures in the gas contained within the tube. Such a device can be used as the driver for a high energy density shock tube or hypervelocity gas gun. The dynamics of the precursor shock wave were investigated for different tube sizes and initial fill pressures. Shock velocity and standoff distance were found to decrease with increasing fill pressure, mainly due to radial expansion of the tube. Adding a tamper can reduce this effect, but may increase jetting. A simple analytical model based on acoustic wave interactions was developed to calculate pump tube expansion and the resulting effect on the shock velocity and standoff distance. Results from this model agree quite well with experimental data.
Influence of bio-fuels on passenger car vehicle emissions
NASA Astrophysics Data System (ADS)
Petrea, M.; Kapernaum, M.; Wahl, C.
2009-04-01
In order to reduce the emissions of air pollutants, vehicles design and fuel formulation have changed. Ultra clean vehicle technologies started to be used in increased number. As a result, the emissions composition is expected to change as well. The use of new technologies and new fuels require new emissions tests especially for non-regulated compounds. The interest in using bio fuels as alternative fuels for petroleum-based ones has increased constantly in the last years. The advantages of the bio fuels usage is given by their similar proprieties, characteristics of renew ability, biodegradability and potential beneficial effects on the exhaust emission. The study involved measurements on a roller test facility of a reference passenger car representing new technologies (emission standards, injection system). The vehicle operated by use of reference gasoline and reference gasoline blended (10 and 20%) with bio-ethanol (EtOH). The measurements used different driving cycles: ARTEMIS cycle, real world driving cycle, NEDC cycle, the standard European driving cycle and additionally, a driving cycle consisting in Idle, 30, 50, 90 km/h. The sampling positions were before and after the catalyst and in the exhaust pipe. The detailed speciation of NMVOC' (non methane volatile organic compounds) was completed by use of active carbon tubes, DNPH (2,4-dinitrophenylhydrazine) tubes and cold traps. The particles were monitored by use of an on-line EEPS (Engine Exhaust Particle Sizer). CO2, NO, NO2 and NOX (NO +NO2) were continuously monitored by use of an on- line FTIR (Fourier transform infrared spectroscopy)- MEXA system. The investigations reveal that among the carbonylic compounds 15 oxygenated species were found in engine out exhaust and only 3 in tailpipe emissions, namely formaldehyde, acetaldehyde and acroleine. These are of great interest due to their impacts on human health. The hydrocarbons emissions decrease by increased of EtOH content. New compounds were observed. The nitro-compounds found in the after engine position by increased EtOH were no more found in the exhaust gas. The results show that total particle concentration, mass and diameter decreased substantially after catalyst and filter by increased ethanol blend.
Filmwise Condensation of Steam on Externally-Finned Horizontal Tubes.
1983-12-01
via gravity to the boiler. The auxiliary condenser was constructed of two 9.5-mm (3/8-in) water- cooled ccpper lines helically coiled to a height of...34. " . .. . ’ . .- .. ’. .. .- . . . i . ’ -, - NPS69-83-003 - m NAVAL POSTGRADUATE SCHOOL Monterey, California THESIS FILMWISE CONDENSATION OF STEAM ON EXTERNALLY-FINNED...and SubEtee) 5. TYPE OF REPORT & PERIOD COVERED Filmwise Condensation of Steam on Master Thesis; Externally-Finned Horizontal Tubes D e r1 6
Asiabi, Hamid; Yamini, Yadollah; Seidi, Shahram; Esrafili, Ali; Rezaei, Fatemeh
2015-06-05
In this work, a novel and efficient on-line in-tube solid phase microextraction method followed by high performance liquid chromatography was developed for preconcentration and determination of trace amounts of parabens. A nanostructured polyaniline-polypyrrole composite was electrochemically deposited on the inner surface of a stainless steel tube and used as the extraction phase. Several important factors that influence the extraction efficiency, including type of solid-phase coating, extraction and desorption times, flow rates of the sample solution and eluent, pH, and ionic strength of the sample solution were investigated and optimized. Under the optimal conditions, the limits of detection were in the range of 0.02-0.04 μg L(-1). This method showed good linearity for parabens in the range of 0.07-50 μg L(-1), with coefficients of determination better than 0.998. The intra- and inter-assay precisions (RSD%, n=3) were in the range of 5.9-7.0% and 4.4-5.7% at three concentration levels of 2, 10, and 20 μg L(-1), respectively. The extraction recovery values for the spiked samples were in the acceptable range of 80.3-90.2%. The validated method was successfully applied for analysis of methyl-, ethyl-, and propyl parabens in some water, milk, and juice samples. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kivotides, Demosthenes
2018-03-01
The interactions between vortex tubes and magnetic-flux rings in incompressible magnetohydrodynamics are investigated at high kinetic and magnetic Reynolds numbers, and over a wide range of the interaction parameter. The latter is a measure of the turnover time of the large-scale fluid motions in units of the magnetic damping time, or of the strength of the Lorentz force in units of the inertial force. The small interaction parameter results, which are related to kinematic turbulent dynamo studies, indicate the evolution of magnetic rings into flattened spirals wrapped around the vortex tubes. This process is also observed at intermediate interaction parameter values, only now the Lorentz force creates new vortical structures at the magnetic spiral edges, which have a striking solenoid vortex-line structure, and endow the flattened magnetic-spiral surfaces with a curvature. At high interaction parameter values, the decisive physical factor is Lorentz force effects. The latter create two (adjacent to the magnetic ring) vortex rings that reconnect with the vortex tube by forming an intriguing, serpentinelike, vortex-line structure, and generate, in turn, two new magnetic rings, adjacent to the initial one. In this regime, the morphologies of the vorticity and magnetic field structures are similar. The effects of these structures on kinetic and magnetic energy spectra, as well as on the direction of energy transfer between flow and magnetic fields, are also indicated.
APPARATUS FOR VACUUM DEPOSITION OF METALS
Milleron, N.
1962-03-13
An apparatus and a method are described for continuous vacuum deposition of metals for metallic coatings, for ultra-high vacuum work, for purification of metals, for maintaining high-density electron currents, and for other uses. The apparatus comprises an externally cooled feeder tube extending into a container and adapted to feed metal wire or strip so that it emerges in a generally vertical position therein. The tube also provides shielding from the heat produced by an electron beam therein focused to impinge from a vertical direction upon the tip of the emerging wire. By proper control of the wire feed, coolant feed, and electron beam intensity, a molten ball of metal forms upon the emerging tip and remains self-supported thereon by the interaction of various forces. The metal is vaporized and travels in a line of sight direction, while additional wire is fed from the tube, so that the size of the molten ball remains constant. In the preferred embodiments, the wire is selected from a number of gettering metals and is degassed by electrical resistance in an adjacent chamber which is also partially evacuated. The wire is then fed through the feed tube into the electron beam and vaporizes and adsorbs gases to provide pumping action while being continuously deposited upon surfaces within the chamber. Ion pump electrodes may also be provided within line of sight of the vaporizing metal source to enhance the pumping action. (AEC)
Shear thinning effects on blood flow in straight and curved tubes
NASA Astrophysics Data System (ADS)
Cherry, Erica M.; Eaton, John K.
2013-07-01
Simulations were performed to determine the magnitude and types of errors one can expect when approximating blood in large arteries as a Newtonian fluid, particularly in the presence of secondary flows. This was accomplished by running steady simulations of blood flow in straight and curved tubes using both Newtonian and shear-thinning viscosity models. In the shear-thinning simulations, the viscosity was modeled as a shear rate-dependent function fit to experimental data. Simulations in straight tubes were modeled after physiologically relevant arterial flows, and flow parameters for the curved tube simulations were chosen to examine a variety of secondary flow strengths. The diameters ranged from 1 mm to 10 mm and the Reynolds numbers from 24 to 1500. Pressure and velocity data are reported for all simulations. In the straight tube simulations, the shear-thinning flows had flattened velocity profiles and higher pressure gradients compared to the Newtonian simulations. In the curved tube flows, the shear-thinning simulations tended to have blunted axial velocity profiles, decreased secondary flow strengths, and decreased axial vorticity compared to the Newtonian simulations. The cross-sectionally averaged pressure drops in the curved tubes were higher in the shear-thinning flows at low Reynolds number but lower at high Reynolds number. The maximum deviation in secondary flow magnitude averaged over the cross sectional area was 19% of the maximum secondary flow and the maximum deviation in axial vorticity was 25% of the maximum vorticity.
Mahmoodpoor, Ata; Hamishehkar, Hadi; Hamidi, Masoud; Shadvar, Kamran; Sanaie, Sarvin; Golzari, Samad Ej; Khan, Zahid Hussain; Nader, Nader D
2017-04-01
Endotracheal tube placement is necessary for the control of the airway in patients who are mechanically ventilated. However, prolonged duration of endotracheal tube placement contributes to the development of ventilator-associated pneumonias (VAPs). The aim of this study was to evaluate whether subglottic suctioning using TaperGuard EVAC tubes was effective in decreasing the frequency of VAP. A total of 276 mechanically ventilated patients for more than 72 hours were randomly assigned to group E (EVAC tube) and group C (conventional tube). All patients received routine care including VAP prevention measures during their intensive care unit stay. In group E, subglottic suctioning was performed every 6 hours. Outcome variables included incidence VAP, intensive care unit length of stay, and mortality. Frequency of intraluminal suction, mechanical ventilation-free days, reintubation, the ratio of arterial oxygen partial pressure to fractional inspired oxygen and mortality rate were similar between the 2 groups (P > .05). The mean cuff pressure in group E was significantly less than that in group C (P < .001). Ventilator-associated pneumonia was significantly less in group E compared with group C (P = .015). The use of intermittent subglottic secretion suctioning was associated with a significant decrease in the incidence of the VAP in critically ill patients. However, larger multicenter trials are required to arrive at a concrete decision on routine usage of TaperGuard tubes in critical care settings. Published by Elsevier Inc.
Surface roughness effects on contact line motion with small capillary number
NASA Astrophysics Data System (ADS)
Yang, Feng-Chao; Chen, Xiao-Peng; Yue, Pengtao
2018-01-01
In this work, we investigate how surface roughness influences contact line dynamics by simulating forced wetting in a capillary tube. The tube wall is decorated with microgrooves and is intrinsically hydrophilic. A phase-field method is used to capture the fluid interface and the moving contact line. According to the numerical results, a criterion is proposed to judge whether the grooves are entirely wetted or not at vanishing capillary numbers. When the contact line moves over a train of grooves, the apparent contact angle exhibits a periodic nature, no matter whether the Cassie-Baxter or the Wenzel state is achieved. The oscillation amplitude of apparent contact angle is analyzed and found to be inversely proportional to the interface area. The contact line motion can be characterized as stick-jump-slip in the Cassie-Baxter state and stick-slip in the Wenzel state. By comparing to the contact line dynamics on smooth surfaces, equivalent microscopic contact angles and slip lengths are obtained. The equivalent slip length in the Cassie-Baxter state agrees well with the theoretical model in the literature. The equivalent contact angles are, however, much greater than the predictions of the Cassie-Baxter model and the Wenzel model for equilibrium stable states. Our results reveal that the pinning of the contact line at surface defects effectively enhances the hydrophobicity of rough surfaces, even when the surface material is intrinsically hydrophilic and the flow is under the Wenzel state.
The Stereo Electron Spikes and the Interplanetary Magnetic Field
NASA Astrophysics Data System (ADS)
Jokipii, J. R.; Sheeley, N. R., Jr.; Wang, Y. M.; Giacalone, J.
2016-12-01
A recent paper (Klassen etal, 2015) discussed observations of a spike event of 55-65 keV electrons which occurred very nearly simultaneously at STEREO A and STEREO B, which at the time were separated in longitude by 38 degrees. The authors associated the spikes with a flare at the Sun near the footpoint of the nominal Archimedean spiral magnetic field line passing through STEREO A. The spike at STEREO A was delayed by 2.2 minutes from that at STEREOB. We discuss the observations in terms of a model in which the electrons, accelerated at the flare, propagate without significant scattering along magnetic field lines which separate or diverge as a function of radial distance from the Sun. The near simultaneity of the spikes at the two spacecraft is a natural consequence of this model. We interpret the divergence of the magnetic field lines as a consequence of field-line random walk and flux-tube expansion. We show that the field-line random walk in the absence of flux-tube expansion produces an rms spread of field lines significantly less than that which is required to produce to observed divergence. We find that observations of the solar wind and its source region at the time of the event can account for the observations in terms of propagation along interplanetary magnetic field-lines. Klassen, A., Dresing, N., Gomez-Herrero, R, and Heber, B., A&A 580, A115 (2015) Financial support for NS and YMW was provided by NASA and CNR.
Ryska, Pavel; Kvasnicka, Tomas; Jandura, Jiri; Klzo, Ludovit; Grepl, Jakub; Zizka, Jan
2014-06-01
To compare the effective and eye lens radiation dose in helical MDCT brain examinations using automatic tube current modulation in conjunction with either standard filtered back projection (FBP) technique or iterative reconstruction in image space (IRIS). Of 400 adult brain MDCT examinations, 200 were performed using FBP and 200 using IRIS with the following parameters: tube voltage 120 kV, rotation period 1 second, pitch factor 0.55, automatic tube current modulation in both transverse and longitudinal planes with reference mAs 300 (FBP) and 200 (IRIS). Doses were calculated from CT dose index and dose length product values utilising ImPACT software; the organ dose to the lens was derived from the actual tube current-time product value applied to the lens. Image quality was assessed by two independent readers blinded to the type of image reconstruction technique. The average effective scan dose was 1.47±0.26 mSv (FBP) and 0.98±0.15 mSv (IRIS), respectively (33.3% decrease). The average organ dose to the eye lens decreased from 40.0±3.3 mGy (FBP) to 26.6±2.0 mGy (IRIS, 33.5% decrease). No significant change in diagnostic image quality was noted between IRIS and FBP scans (P=0.17). Iterative reconstruction of cerebral MDCT examinations enables reduction of both effective and organ eye lens dose by one third without signficant loss of image quality.
Effect of layerwise structural inhomogeneity on stress- corrosion cracking of steel tubes
NASA Astrophysics Data System (ADS)
Perlovich, Yu A.; Krymskaya, O. A.; Isaenkova, M. G.; Morozov, N. S.; Fesenko, V. A.; Ryakhovskikh, I. V.; Esiev, T. S.
2016-04-01
Based on X-ray texture and structure analysis data of the material of main gas pipelines it was shown that the layerwise inhomogeneity of tubes is formed during their manufacturing. The degree of this inhomogeneity affects on the tendency of tubes to stress- corrosion cracking under exploitation. Samples of tubes were cut out from gas pipelines located under various operating conditions. Herewith the study was conducted both for sections with detected stress-corrosion defects and without them. Distributions along tube wall thickness for lattice parameters and half-width of X-ray lines were constructed. Crystallographic texture analysis of external and internal tube layers was also carried out. Obtained data testifies about considerable layerwise inhomogeneity of all samples. Despite the different nature of the texture inhomogeneity of gas pipeline tubes, the more inhomogeneous distribution of texture or structure features causes the increasing of resistance to stress- corrosion. The observed effect can be explained by saturation with interstitial impurities of the surface layer of the hot-rolled sheet and obtained therefrom tube. This results in rising of lattice parameters in the external layer of tube as compared to those in underlying metal. Thus, internal layers have a compressive effect on external layers in the rolling plane that prevents cracks opening at the tube surface. Moreover, the high mutual misorientation of grains within external and internal layers of tube results in the necessity to change the moving crack plane, so that the crack growth can be inhibited when reaching the layer with a modified texture.
Risks of Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... of cancer, including ovarian cancer, or other conditions. Studies have also shown that ... Screening tests have risks. The risks of ovarian, fallopian tube, ...
Effect of gravity on liquid plug transport through an airway bifurcation model.
Zheng, Y; Anderson, J C; Suresh, V; Grotberg, J B
2005-10-01
Many medical therapies require liquid plugs to be instilled into and delivered throughout the pulmonary airways. Improving these treatments requires a better understanding of how liquid distributes throughout these airways. In this study, gravitational and surface mechanisms determining the distribution of instilled liquids are examined experimentally using a bench-top model of a symmetrically bifurcating airway. A liquid plug was instilled into the parent tube and driven through the bifurcation by a syringe pump. The effect of gravity was adjusted by changing the roll angle (phi) and pitch angle (gamma) of the bifurcation (phi = gamma =0 deg was isogravitational). Phi determines the relative gravitational orientation of the two daughter tubes: when phi not equal to 0 deg, one daughter tube was lower (gravitationally favored) compared to the other. Gamma determines the component of gravity acting along the axial direction of the parent tube: when gamma not equal to 0 deg, a nonzero component of gravity acts along the axial direction of the parent tube. A splitting ratio Rs, is defined as the ratio of the liquid volume in the upper daughter to the lower just after plug splitting. We measured the splitting ratio, Rs, as a function of: the parent-tube capillary number (Cap); the Bond number (Bo); phi; gamma; and the presence of pre-existing plugs initially blocking either daughter tube. A critical capillary number (Cac) was found to exist below which no liquid entered the upper daughter (Rs = 0), and above which Rs increased and leveled off with Cap. Cac increased while Rs decreased with increasing phi, gamma, and Bo for blocked and unblocked cases at a given Cap > Ca,. Compared to the nonblockage cases, Rs decreased (increased) at a given Cap while Cac increased (decreased) with an upper (lower) liquid blockage. More liquid entered the unblocked daughter with a blockage in one daughter tube, and this effect was larger with larger gravity effect. A simple theoretical model that predicts Rs and Cac is in qualitative agreement with the experiments over a wide range of parameters.
Transport Loss Estimation of Fine Particulate Matter in Sampling Tube Based on Numerical Computation
NASA Astrophysics Data System (ADS)
Luo, L.; Cheng, Z.
2016-12-01
In-situ measurement of PM2.5 physical and chemical properties is one substantial approach for the mechanism investigation of PM2.5 pollution. Minimizing PM2.5 transport loss in sampling tube is essential for ensuring the accuracy of the measurement result. In order to estimate the integrated PM2.5 transport efficiency in sampling tube and optimize tube designs, the effects of different tube factors (length, bore size and bend number) on the PM2.5 transport were analyzed based on the numerical computation. The results shows that PM2.5 mass concentration transport efficiency of vertical tube with flowrate at 20.0 L·min-1, bore size at 4 mm, length at 1.0 m was 89.6%. However, the transport efficiency will increase to 98.3% when the bore size is increased to 14 mm. PM2.5 mass concentration transport efficiency of horizontal tube with flowrate at 1.0 L·min-1, bore size at 4mm, length at 10.0 m is 86.7%, increased to 99.2% with length at 0.5 m. Low transport efficiency of 85.2% for PM2.5 mass concentration is estimated in bend with flowrate at 20.0 L·min-1, bore size at 4mm, curvature angle at 90o. Laminar flow of air in tube through keeping the ratio of flowrate (L·min-1) and bore size (mm) less than 1.4 is beneficial to decrease the PM2.5 transport loss. For the target of PM2.5 transport efficiency higher than 97%, it is advised to use vertical sampling tubes with length less than 6.0 m for the flowrates of 2.5, 5.0, 10.0 L·min-1 and bore size larger than 12 mm for the flowrates of 16.7 or 20.0 L·min-1. For horizontal sampling tubes, tube length is decided by the ratio of flowrate and bore size. Meanwhile, it is suggested to decrease the amount of the bends in tube of turbulent flow.
Study on Influence of Tube Arrays on Fluid Elastic Instability
NASA Astrophysics Data System (ADS)
Ishihara, Kunihiko; Kitayama, Gen
The tube bank is used in boilers, heat exchangers in power plants and steam generators in nuclear plants. These tubes sometimes vibrate violently and come to the fatigue failure due to the flow induced vibration which is caused by the cross flow. This phenomenon is that the large vibrations arise at the critical flow velocity and it is called fluid elastic instability. However the relation between the onset velocity of fluid elastic instability and the tube array's geometry has not been clarified sufficiently. There is a few reference related to the relation between the pitch to diameter ratio and the onset velocity even in the lattice arrays. In this paper, the influence of tube arrays on fluid elastic instability is examined by experiments. As a result, it is clarified that the tube vibrations become large as T/D increases and L/D decreases, and the tube vibrations strongly depend on the dynamic characteristics of tubes such as the natural frequency and the damping ability.
Studies on equatorial shock formation during plasmaspheric refilling
NASA Technical Reports Server (NTRS)
Singh, N.
1994-01-01
Investigations based on small-scale simulations of microprocesses occurring when a magnetic flux tube refills with a cold plasma are summarized. Results of these investigations are reported in the following attached papers: (1) 'Numerical Simulation of Filling a Magnetic Flux Tube with a Cold Plasma: The Role of Ion Beam-Driven Instabilities'; and (2) 'Numerical Simulation of Filling a Magnetic Flux Tube with a Cold Plasma: Effects of Magnetically Trapped Hot Plasma'. Other papers included are: 'Interaction of Field-Aligned Cold Plasma Flows with an Equatorially-Trapped Hot Plasma: Electrostatic Shock Formation'; and 'Comparison of Hydrodynamic and Semikinetic Treatments for a Plasma Flow along Closed Field Lines'. A proposal for further research is included.
Ionization tube simmer current circuit
Steinkraus, R.F. Jr.
1994-12-13
A highly efficient flash lamp simmer current circuit utilizes a fifty percent duty cycle square wave pulse generator to pass a current over a current limiting inductor to a full wave rectifier. The DC output of the rectifier is then passed over a voltage smoothing capacitor through a reverse current blocking diode to a flash lamp tube to sustain ionization in the tube between discharges via a small simmer current. An alternate embodiment of the circuit combines the pulse generator and inductor in the form of an FET off line square wave generator with an impedance limited step up output transformer which is then applied to the full wave rectifier as before to yield a similar simmer current. 6 figures.
METAL SPRAYER FOR USE IN VACUUM OR INERT ATMOSPHERE
Monroe, R.E.
1958-10-14
A metal sprayer is described for use in a vacuum or inert atmosphere with a straight line wire feed and variable electrode contact angle. This apparatus comprises two wires which are fed through straight tubes of two mechanisms positioned on opposite sides of a central tube to which an inert gas is fed. The two mechanisms and the wires being fed constitute electrodes to which electrical current is supplied so that the wires are melted by the electric are formed at their contacting region and sprayed by the gas supplied by the central tube. This apparatus is designed specifically to apply a zirconium coating to uranium in an inert atmosphere and without the use of an oxidizing flame.
Ionization tube simmer current circuit
Steinkraus, Jr., Robert F.
1994-01-01
A highly efficient flash lamp simmer current circuit utilizes a fifty percent duty cycle square wave pulse generator to pass a current over a current limiting inductor to a full wave rectifier. The DC output of the rectifier is then passed over a voltage smoothing capacitor through a reverse current blocking diode to a flash lamp tube to sustain ionization in the tube between discharges via a small simmer current. An alternate embodiment of the circuit combines the pulse generator and inductor in the form of an FET off line square wave generator with an impedance limited step up output transformer which is then applied to the full wave rectifier as before to yield a similar simmer current.
Remotely Triggered Cisplatin Release from Carbon Nanocapsules by Radiofrequency Fields
Raoof, Mustafa; Cisneros, Brandon T.; Guven, Adem; Corr, Stuart J.; Wilson, Lon J.; Curley, Steven A.
2013-01-01
The efficacy of nanoparticle-mediated drug delivery is limited by its peri-vascular sequestration, thus necessitating a strategy to trigger drug release from such intra-tumoral nanocarrier-drug depots. In our efforts to explore remotely-activated nanocarriers, we have developed carbon nanocapsules comprised of an ultrashort carbon nanotube shell (US-tubes) loaded with cisplatin (CDDP@US-tubes) and covered with a Pluronic surfactant wrapping to minimize passive release. We demonstrate here that non-invasive radiofrequency (RF) field activation of the CDDP@US-tubes produces heat that causes Pluronic disruption which triggers cisplatin release in an RF-dependent manner. Furthermore, release-dependent cytotoxicity is demonstrated in human hepatocellular carcinoma cell lines. PMID:23228421
NASA Astrophysics Data System (ADS)
Kenchington, Ellen L. R.; Gilkinson, Kent D.; MacIsaac, Kevin G.; Bourbonnais-Boyce, Cynthia; Kenchington, Trevor J.; Smith, Stephen J.; Gordon, Donald C., Jr.
2006-10-01
The effects of otter trawling on a hard-bottom ecosystem on Western Bank on Canada's Scotian Shelf were examined experimentally from 1997 to 1999 with an asymmetrical BACI design. The site was located within an area that had been closed to fishing since 1987 to protect juvenile haddock. An experimental line was trawled 12-14 times on three separate occasions over a 20 month period. The benthic macrofauna and megafauna were sampled before and after trawling on both impact and control lines with both a grab and a photographic system. The 100 grab samples collected contained 341 taxa, primarily polychaetes, amphipods and molluscs, the majority (60%) of which were epifaunal. Biomass was dominated by the horse-mussel Modiolus modiolus, a long-lived bivalve, while the tube-building amphipod Ericthonius fasciatus was the most abundant species. Through the study period the benthos on the control lines showed little qualitative or quantitative change in individual taxa or community metrics. However, the abundance of 24 individual taxa (polychaetes, amphipods, echinoderms and molluscs) changed significantly, with the majority of these increasing. This resulted in a significantly different relative abundance of taxa between years as detected through ANOSIM. A significant change in relative biomass amongst the taxa was also observed. Trawling had few detectable immediate effects on the abundance or biomass of individual taxa and none on community composition. A few taxa, primarily a mixture of polychaetes and amphipods, decreased significantly after trawling and data from fish stomachs collected during the experiment (Kenchington, E.L., Gordon Jr., D.C., Bourbonnais-Boyce, C., MacIsaac, K.G., Gilkinson, K.D., McKeown, D.L., Vass, W.P., 2005. Effects of experimental otter trawling on the feeding of demersal fish on Western Bank, Nova Scotia. Amer. Fish. Soc. Symp. 41, 391-409) showed that some of these were scavenged by demersal fish. Fifteen taxa showed significant decreases after trawling when the cumulative effects of trawling were considered. As in the analyses of individual years the species affected were primarily high turn-over species such as polychaetes and amphipods. Dominance curves prepared for both control and impact samples before trawling in 1997 and after trawling in 1999 showed a marked decrease in the biomass values of the highest ranking taxa, particularly of the first species, M. modiolus, only on the impact line at the conclusion of the experiment. The proportion of epifaunal biomass also declined significantly from 90% to 77% on the impact line by the conclusion of the experiment. These changes are in part due to trawl-induced damage and subsequent predation by demersal fish of the top ranking species. Analysis of the photographic images showed that the three top-ranking species in terms of biomass, M. modiolus, the tube-building polychaete Thelepus cincinnatus, and the brachiopod Terebratulina septentrionalis, were visibly damaged more than other species by the trawl gear. Two of these species, M. modiolus and T. cincinnatus, were preyed upon by scavenging demersal fish. The use of multiple sampling devices at the experimental site (grab, photographic system reported here and trawl and fish stomachs reported by Kenchington, E.L., Gordon Jr., D.C., Bourbonnais-Boyce, C., MacIsaac, K.G., Gilkinson, K.D., McKeown, D.L., Vass, W.P., 2005. Effects of experimental otter trawling on the feeding of demersal fish on Western Bank, Nova Scotia. Amer. Fish. Soc. Symp. 41, 391-409) enabled us to link trawl-induced changes to the benthos to predation by demersal fish.
Breckenridge, R Reid; Bartholomew, Luanna R; Crosson, Craig E; Kent, Alexander R
2004-10-01
To determine outflow resistance of the Baerveldt glaucoma implant using different tube configurations. Outflow resistance of 6 tube configurations (C1- C6) of Baerveldt implants was measured under conditions of constant pressure perfusion. Pressures ranged from 2 to 55 mm Hg. Venting slits were created using a 7-0 Vicryl, spatulated suture-needle. Seton tubes were occluded by threading a retrograde suture approximately 1.5 cm into the lumen. At pressures between 2 and 55 mm Hg, mean outflow resistance of the normally configured seton (ie, open tube; C1) was 0.41 (+/- 0.6) mm Hg/microL/min. Resistance was unchanged (mean 0.41 (+/- 0.4) mm Hg/microL/min) by the addition of 4 venting slits (C2) to the seton tube. Occlusion of the open seton tube with a 3-0 Supramid suture (C3) significantly increased (P < 0.001) mean outflow resistance to 14.99 (+/- 0.6) mm Hg/microL/min. Occlusion of the tube with a 4-0 Supramid suture (C4) significantly increased (P < 0.001) mean outflow resistance to 1.09 (+/- 0.5) mm Hg/microL/min. In implants where tubes were occluded with a 3-0 Supramid suture, the addition of venting slits (C5) significantly decreased (P = 0.038) mean outflow resistance to 8.98 (+/- 0.4) mm Hg/microL/min. In tubes occluded with a 4-0 Supramid suture, the addition of venting slits (C6) decreased mean outflow resistance to 0.98 (+/- 0.6) mm Hg/microL/min. Although these results cannot be directly correlated to the clinical setting, they do show that outflow resistance can be modified at the time of surgery by changing tube configuration of the Baerveldt glaucoma implant. Configuration C5 (3-0 Supramid with venting slits) closely approximates the outflow rate in the normal intraocular pressure range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Amours, Guillaume; Rahem, Ahmed; Mayer, Robert
2007-05-17
The motivation to reduce overall vehicle weight within the automotive sector drives the substitution of lightweight materials such as aluminium alloys for structural components. Such a substitution requires a significant amount of development to manufacture structurally parts such that the energy absorption characteristics are not sacrificed in the event of crash. The effects of the manufacturing processes on the crash performance of automotive structural components must be better understood to ensure improved crashworthiness. This paper presents results of an experimental and numerical investigation of the crash response and energy absorption properties of impacted hydroformed aluminium alloy tubes. Crash experiments onmore » hydroformed tubes were performed using a deceleration sled test at the General Motors Technical Center. Results from axial crush testing showed that an important parameter that influences the energy absorption characteristics during crash was the thickness reduction caused by circumferential expansion of the tube during hydroforming. It was found that that the energy absorption decreased as the corner radius decreased, which results because of increased thinning. Sensitivity studies of end feeding parameters, such as end feed level and profile, were carried out to evaluate their impact on the energy absorption of the aluminium tubes.« less
NASA Astrophysics Data System (ADS)
D'Amours, Guillaume; Rahem, Ahmed; Mayer, Robert; Williams, Bruce; Worswick, Michael
2007-05-01
The motivation to reduce overall vehicle weight within the automotive sector drives the substitution of lightweight materials such as aluminium alloys for structural components. Such a substitution requires a significant amount of development to manufacture structurally parts such that the energy absorption characteristics are not sacrificed in the event of crash. The effects of the manufacturing processes on the crash performance of automotive structural components must be better understood to ensure improved crashworthiness. This paper presents results of an experimental and numerical investigation of the crash response and energy absorption properties of impacted hydroformed aluminium alloy tubes. Crash experiments on hydroformed tubes were performed using a deceleration sled test at the General Motors Technical Center. Results from axial crush testing showed that an important parameter that influences the energy absorption characteristics during crash was the thickness reduction caused by circumferential expansion of the tube during hydroforming. It was found that that the energy absorption decreased as the corner radius decreased, which results because of increased thinning. Sensitivity studies of end feeding parameters, such as end feed level and profile, were carried out to evaluate their impact on the energy absorption of the aluminium tubes.
Optical and UV Sensing Sealed Tube Microchannel Plate Imaging Detectors with High Time Resolution
NASA Astrophysics Data System (ADS)
Siegmund, O.; Vallerga, J.; Tremsin, A.; Hull, J.; Elam, J.; Mane, A.
2014-09-01
Microchannel plate (MCP) based imaging, photon time tagging detector sealed tube schemes have a unique set of operational features that enable high time resolution astronomical and remote sensing applications to be addressed. New detectors using the cross strip (XS), cross delay line (XDL), or stripline anode readouts, a wide range of photocathode types, and advanced MCP technologies have been implemented to improve many performance characteristics. A variety of sealed tubes have been developed including 18mm XS readout devices with GaAs and SuperGenII photocathodes, 25mm XDL readout devices with SuperGenII and GaN photocathodes, and 20 x 20 cm sealed tubes with bialkali photocathodes and strip line readout. One key technology that has just become viable is the ability to make MCPs using atomic layer deposition (ALD) techniques. This employs nanofabrication of the active layers of an MCP on a microcapillary array. This technique opens new performance opportunities, including, very large MCP areas (>20cm), very low intrinsic background, lower radiation induced background, much longer overall lifetime and gain stability, and markedly lower outgassing which can improve the sealed tube lifetime and ease of fabrication. The XS readout has been implemented in formats of 22mm, 50mm and 100mm, and uses MCP charge signals detected on two orthogonal layers of conductive fingers to encode event X-Y positions. We have achieved spatial resolution XS detectors better than 25 microns FWHM, with good image linearity while at low gain (<10^6), substantially increasing local counting rate capabilities and the overall tube lifetime. XS tubes with updated electronics can encode event rates of >5 MHz with ~12% dead time and event timing accuracy of ~100ps. XDL sealed tubes in 25mm format demonstrate ~40 micron spatial resolution at up to ~2 MHz event rates, and have been developed with SupergenII visible regime photocathodes. The XDL tubes also achieve ~100 ps time resolution. Most recently ALD MCPs with an opaque GaN photocathode (100-350nm range) on the MCP surface has been demonstrated in a sealed tube configuration. These ALD MCPs show a stable and permanent 10x gain increase during tube processing. Efforts are also underway to establish ALD MCP configurations with large area sealed tubes from 5cm up to 20cm in size. We will discuss these efforts and their performance characteristics. We will discuss how we are applying these detector system developments to a number of applications. This includes ground based instruments for observations of transient and variable astronomical objects, as well as implementation in satellite instruments for earth atmospheric and solar observations. The XS 18mm sealed tube detectors are being implemented for night time remote reconnaissance and biological single-molecule fluorescence lifetime imaging microscopy. Related efforts also include development of large (20cm) sealed tubes for Cherenkov light detection and large area focal plane imagers, and GaN sealed tube devices are candidates for future astronomical space based UV imaging and spectroscopy.
2016-01-01
Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with S-nitroso-N-acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10–10 mol min–1 cm–2 for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species (Staphylococcus epidermidis and Proteus mirabilis) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs. PMID:26462294
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-06
... tubes that would be incorporated into the dyke; (5) a 69 kilovolt transmission line conveying the....asp . You must include your name and contact information at the end of your comments. For assistance...
Blood Transfusions (For Teens)
... person usually gets a blood transfusion through an intravenous line , a tiny tube that is inserted into ... blood cells. So some people getting treatment for cancer might need a transfusion of red blood cells ...
Nonlinear acoustic streaming in straight and tapered tubes
NASA Astrophysics Data System (ADS)
Tuttle, Brian C.
In thermoacoustic and Stirling devices such as the pulse-tube refrigerator, efficiency is diminished by the formation of a second-order mean velocity known as Rayleigh streaming. This flow emerges from the interaction of the working gas with the wall of the tube in a thin boundary layer. Recent studies have suggested that streaming velocity can be decreased in a tube by tapering it slightly. This research investigates that claim through the development of a numerical model of Rayleigh streaming in variously tapered tubes. It is found that the numerical simulation of streaming in a straight tube compares well with theory, and the application of different thermal boundary conditions at the tube wall shows that for pressurized helium, inner streaming vortices which appear near an adiabatic tube wall do not develop near an isothermal wall. An order analysis indicates that the temperature dependence of viscosity and thermal conductivity contributes appreciably to an accurate numerical model of streaming. Comparison of Rayleigh streaming in tapered tubes shows the effects of taper angle on the circulation and velocity of the mean flow.
Leakage effect analysis on the performance of a cylindrical adjustable inertance tube
NASA Astrophysics Data System (ADS)
Zhou, Wenjie; Pfotenhauer, John M.; Zhi, Xiaoqin
2018-04-01
The inertance tube plays a significant role in improving the performance of the Stirling type pulse tube cryocooler by providing the desired phase angle between the mass flow and pressure wave. The phase angle is highly depended on the inertance tube geometry, such as diameter and length. A cylindrical threaded root device with variable thread depth on the outer screw and inner screw creates an adjustable inertance tube whose diameter and length can be adjusted in the real time. However, due to its geometry imperfectness, the performance of this threaded inertance tube is reduced by the leaks through the roots between the two screws. Its phase angle shift ability is decreased by 30% with the leakage clearance thickness of 15.5 μm according to both the theoretical prediction and the experimental verification.
NASA Astrophysics Data System (ADS)
Choi, Yong; Hong, Sun I.
2014-12-01
Nano-tubes of titanium and zirconium alloys like Ti-6Al-4V-1Nb and Zr-1Nb were prepared by anodization followed by coating with hydroxylapatite (HA) and their bio-mineralization behaviors were compared to develop a bio-compatible material for implants in orthopedics, dentistry and cardiology. Ti-6Al-4V-1Nb weight gain in a simulated body solution increased gradually. The bigger tube diameter was, the heavier HA was deposited. Surface roughness of both alloys increased highly with the increasing diameter of nano-tube. Their surface roughness decreased by HA deposition due to the removal of the empty space of the nano-tubes. Zr-1Nb alloy had faster growth of nano-tubes layers more than Ti-6Al-4V-1Nb alloy.
The Effect of Tubing Dwell Time on Insulin Adsorption During Intravenous Insulin Infusions
Vital-Carona, Jessica; Faustino, E. Vincent S.
2012-01-01
Abstract Background Insulin adsorbs to plastic tubing, which decreases the concentration of an insulin solution delivered from an intravenous infusion set. Dwelling insulin within tubing before starting the infusion decreases adsorption but delays treatment initiation and wastes time in infusion preparation. The lack of data on dwell time effects results in wide variability in practice. We aim to determine the effect of dwell time on insulin concentration from intravenous infusion tubing. Materials and Methods In this in vitro study, we used insulin solutions with concentrations of 0.1 unit/mL, 1 unit/mL, and 10 units/mL. Each solution dwelled in intravenous infusion sets for 0, 15, 30, or 60 min. After the dwell, we measured insulin concentrations from the solution bags and tubing. We repeated each insulin concentration–dwell time combination five times. Comparisons were performed using analyses of variance. Results For each of the three insulin concentrations, the mean insulin concentrations from the tubing were not significantly different between dwell times. Duration of dwell time did not affect insulin adsorption in polypropylene intravenous infusion sets. Conclusions We recommend that following a 20-mL flush, insulin infusions can be started without any dwell time. Removal of dwell times may improve clinical practice by minimizing preparation time and will allow faster initiation of insulin infusion therapy. PMID:22746979
Water Relations, Gas Exchange, and Nutrient Response to a Long Term Constant Water Deficit
NASA Technical Reports Server (NTRS)
Berry, Wade L.; Goldstein, Guillermo; Dreschel, Thomas W.; Wheeler, Raymond M.; Sager, John C.; Knott, William M.
1992-01-01
Wheat plants (Triticum aestivum) were grown for 43 days in a micro-porous tube nutrient delivery system. Roots were unable to penetrate the microporous tube, but grew on the surface and maintained capillary contact with the nutrient solution on the inside of the tube through the 5-microns pores of the porous tube. Water potential in the system was controlled at -0.4, -0.8, and -3.0 kPa by adjusting the applied pressure (hydrostatic head) to the nutrient solution flowing through the microporous tubes. A relatively small decrease in applied water potential from -0.4 to -3.0 kPa resulted in a 34% reduction of shoot growth but only a moderate reduction in the mid-day leaf water potential from - 1.3 to - 1.7 MPa. Carbon dioxide assimilation decreased and water use efficiency increased with the more negative applied water Potentials, while intercellular C02 concentration remained constant. The physiological responses observed in this study in response to small constant differences in applied water potentials were much greater than expected from either the applied water potential or the observed plant water potential. Even though the micro-porous tube may not represent natural conditions and could possibly introduce morphological and physiological artifacts , it enables a high degree of control of water potential that facilitates the investigation of many aspects of water relations not practical with other experimental systems.
Ai, Zhijiu; Sun, Xu; Fu, Biwei
2016-01-01
Analytical buckling models are important for down-hole operations to ensure the structural integrity of the drill string. A literature survey shows that most published analytical buckling models do not address the effects of inclination angle, boundary conditions or friction. The objective of this paper is to study the effects of boundary conditions, friction and angular inclination on the helical buckling of coiled tubing in an inclined wellbore. In this paper, a new theoretical model is established to describe the buckling behavior of coiled tubing. The buckling equations are derived by applying the principles of virtual work and minimum potential energy. The proper solution for the post-buckling configuration is determined based on geometric and natural boundary conditions. The effects of angular inclination and boundary conditions on the helical buckling of coiled tubing are considered. Many significant conclusions are obtained from this study. When the dimensionless length of the coiled tubing is greater than 40, the effects of the boundary conditions can be ignored. The critical load required for helical buckling increases as the angle of inclination and the friction coefficient increase. The post-buckling behavior of coiled tubing in different configurations and for different axial loads is determined using the proposed analytical method. Practical examples are provided that illustrate the influence of the angular inclination on the axial force. The rate of change of the axial force decreases with increasing angular inclination. Moreover, the total axial friction also decreases with an increasing inclination angle. These results will help researchers to better understand helical buckling in coiled tubing. Using this knowledge, measures can be taken to prevent buckling in coiled tubing during down-hole operations. PMID:27649535
Gong, Yinchun; Ai, Zhijiu; Sun, Xu; Fu, Biwei
2016-01-01
Analytical buckling models are important for down-hole operations to ensure the structural integrity of the drill string. A literature survey shows that most published analytical buckling models do not address the effects of inclination angle, boundary conditions or friction. The objective of this paper is to study the effects of boundary conditions, friction and angular inclination on the helical buckling of coiled tubing in an inclined wellbore. In this paper, a new theoretical model is established to describe the buckling behavior of coiled tubing. The buckling equations are derived by applying the principles of virtual work and minimum potential energy. The proper solution for the post-buckling configuration is determined based on geometric and natural boundary conditions. The effects of angular inclination and boundary conditions on the helical buckling of coiled tubing are considered. Many significant conclusions are obtained from this study. When the dimensionless length of the coiled tubing is greater than 40, the effects of the boundary conditions can be ignored. The critical load required for helical buckling increases as the angle of inclination and the friction coefficient increase. The post-buckling behavior of coiled tubing in different configurations and for different axial loads is determined using the proposed analytical method. Practical examples are provided that illustrate the influence of the angular inclination on the axial force. The rate of change of the axial force decreases with increasing angular inclination. Moreover, the total axial friction also decreases with an increasing inclination angle. These results will help researchers to better understand helical buckling in coiled tubing. Using this knowledge, measures can be taken to prevent buckling in coiled tubing during down-hole operations.
Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.
Canby-Hagino, E D; Caballero, R D; Harmon, W J
1999-12-01
Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.
Copper Tube Pitting in Santa Fe Municipal Water Caused by Microbial Induced Corrosion.
Burleigh, Thomas D; Gierke, Casey G; Fredj, Narjes; Boston, Penelope J
2014-06-05
Many copper water lines for municipal drinking water in Santa Fe, New Mexico USA, have developed pinhole leaks. The pitting matches the description of Type I pitting of copper, which has historically been attributed to water chemistry and to contaminants on the copper tubing surface. However, more recent studies attribute copper pitting to microbial induced corrosion (MIC). In order to test for microbes, the copper tubing was fixed in hexamethyldisilazane (HMDS), then the tops of the corrosion mounds were broken open, and the interior of the corrosion pits were examined with scanning electron microscopy (SEM). The analysis found that microbes resembling actinobacteria were deep inside the pits and wedged between the crystallographic planes of the corroded copper grains. The presence of actinobacteria confirms the possibility that the cause of this pitting corrosion was MIC. This observation provides better understanding and new methods for preventing the pitting of copper tubing in municipal water.
Thin liquid film in polymer tubing : dynamics and dewetting in partial wetting condition
NASA Astrophysics Data System (ADS)
Hayoun, Pascaline; Letailleur, Alban; Teisseire, Jérémie; Verneuil, Emilie; Lequeux, François; Barthel, Etienne
2015-11-01
Polymers such as PVC and Silicone are low cost materials widely used in industry to produce tubing for fluid transport. Most of these applications involve repeated, intermittent flow of liquids which can lead to unwanted contamination. This study aims at better understanding contamination mechanisms during intermittent flow in polymer tubing, and at elucidating the relation between flow, wetting and contamination. We experimentally and theoretically investigate, flow regimes as well as dewetting process at the triple line induced by gravity flow of a vertical liquid slug in a cylindrical geometry. Our results for Newtonian fluids evidence a succession of thick film formation, hydraulic jump creation in the thickness profile, oscillatory regime and destabilization leading to substrate contamination. In order to understand theoretically the flow, one crucial quantity to assess is the film thickness in the inside of the tube. Based on an absorption measurement method, we provide explanations for behaviors and flow regimes observed experimentally.
Copper Tube Pitting in Santa Fe Municipal Water Caused by Microbial Induced Corrosion
Burleigh, Thomas D.; Gierke, Casey G.; Fredj, Narjes; Boston, Penelope J.
2014-01-01
Many copper water lines for municipal drinking water in Santa Fe, New Mexico USA, have developed pinhole leaks. The pitting matches the description of Type I pitting of copper, which has historically been attributed to water chemistry and to contaminants on the copper tubing surface. However, more recent studies attribute copper pitting to microbial induced corrosion (MIC). In order to test for microbes, the copper tubing was fixed in hexamethyldisilazane (HMDS), then the tops of the corrosion mounds were broken open, and the interior of the corrosion pits were examined with scanning electron microscopy (SEM). The analysis found that microbes resembling actinobacteria were deep inside the pits and wedged between the crystallographic planes of the corroded copper grains. The presence of actinobacteria confirms the possibility that the cause of this pitting corrosion was MIC. This observation provides better understanding and new methods for preventing the pitting of copper tubing in municipal water. PMID:28788679
NASA Astrophysics Data System (ADS)
Wang, Guoliang; Zheng, Tianlun; Lu, Tongxia; Wang, Yinong; Yu, Hong; Jin, Shan
2002-10-01
The bacterial flora in the digestive tube of Bullacta exarata Philippi and its rearing shoal were investigated. A total of 157 strains of heterotrophic bacteria, isolated from crop, stomach intestine and other parts of the digestive tube, mainly belong to the genera Photobacterium, Bacillus, Pseudomonas Vibrio and some genera of the family Enterobacteriaceae. There are significantly more varieties of bacteria in crop than in stomach and intestine. A total of 173 strains of bacteria were isolated from the rearing shoal, belonging to 13 genera. The 5 predominant genera, such as Bacillus and Photobacterium, are the same as those in the digestive tube, but greatly differ in percentages. The number of heterotrophic bacteria and Vibrio in rearing shoal change in line with the alteration of the temperature, and are significantly affected by the use of pesticides.
Unique methods for on-orbit structural repair, maintenance, and assembly
NASA Technical Reports Server (NTRS)
Anderson, Ray; Fuson, Phil
1994-01-01
This paper reviews the MDA independent research and development (IRAD) efforts since 1986 in the development of two distinctly different approaches to on-orbit tube repair: (1) one-piece mechanical tube fittings that are forced, under pressure, onto the tube outer surface to effect the repair; and (2) electron beam weldings as demonstrated with the Paton-developed universal hand tool (UHT) space welding system for the repair of fluid lines and tubular components. Other areas of potential on-orbit repair using the UHT include damage to the flat or curved surfaces of habitation modules and truss assemblies. This paper will also address MDA evaluation of the Paton UHT system for on-orbit coating, cleaning, brazing, and cutting of metals. MDA development of an on-orbit compatible nondestructive evaluation (NDE) system for the inspection of tube welds is an important part of this complete space welding capability and will be discussed in a separate paper.
Feng, Benny; Tang, Patricia; Leung, Sharon Shui Yee; Dhanani, Jayesh; Chan, Hak-Kim
2017-04-01
Mechanically ventilated patients commonly suffer from ventilator-associated pneumonia, hypoxemia, and other lower respiratory tract infection as a result of pathogen colonization and poor sputum clearance. Consequently, there is a high rate of morbidity and mortality in these patients. Dry powder mannitol increases sputum clearance, and therefore, we developed a system to administer it to mechanically ventilated patients without disconnection from the ventilator. The inspiratory line from a ventilator was split by using a three-way valve into two parallel lines where one contains a humidifier for normal breathing cycle and the other line contains a dry powder inhaler (Osmohaler™). The inspiratory air went through the dry powder line and aerosolized the mannitol powder only when its administration to a patient is required. We determined the delivered dose and particle size distributions of emitted aerosols in vitro from 9.5 mm endotracheal and 7.5 mm tracheostomy tubes, with inspiratory airflow of 60, 70, and 80 L/min. This novel setup was able to deliver 24.6% ± 3.33% of the 160 mg loaded dose mannitol powder (4 × 40 mg capsules) and 26.7% ± 2.19% of the 320 mg dose (4 × 80 mg capsules) when the endotracheal tube was used. With the shorter tracheostomy tube, the delivery dose increased to 35.6% ± 3.01% and 39.5% ± 2.04% of the 160 and 320 mg doses, respectively. The volume median diameters of the aerosols were in the respirable range with the largest value being 5.17 ± 0.87 μm. This delivery system has been shown to consistently deliver a high respirable dose of mannitol powder. Since this setup does not require disconnection of patients from the ventilator, it is safer for hypoxemic patients and easier to be adapted in a real clinical use.
1990-11-15
degradation or magneto Fo -longer length (L) 1the survival probabilty is hydrodynamic effect. The polymeric materials may also outgas dissolved hydrogen or...pressure tube, together with the methcd of will outgas up to 8cc(H 2)/km. This gives an waterblocking the tube bore, will be identical increase in optical...lines Relative humidity: up to 100% (@ 350 C) not exceeding 200 km. These cables traditionally consist of quads with Second-generation long-distance
Improvement of a Continuous-Culture Apparatus for Long-Term Use1
Taub, Frieda B.; Dollar, Alexander M.
1968-01-01
A glass and plastic apparatus was designed to meet requirements for continuous culture of cells. Some of the improvements incorporated into this apparatus include an all-glass growth vessel with a self-cleaning bottom, special compression fittings to connect tubing to glass tubing, a removable yield reservoir, and a nonwetting gas exhaust assembly. All portions of the system can be autoclaved for sterilization, and medium bottles and pump lines are replaced aseptically. Images Fig. 1 PMID:5645410
Flexible collapse-resistant and length-stable vaccum hose
Kashy, David H.
2003-08-19
A hose for containing a vacuum, which hose has an impermeable flexible tube capable of holding a vacuum and a braided or interwoven flexible interior wall, said wall providing support to said interior wall of said impermeable flexible tube. Optionally, an exterior braided or woven wall may be provided to the hose for protection or to allow the hose to be used as a pressure hose. The hose may delimit a vacuum space through which may travel a thermal transfer line containing, for example, cryogenic fluid.
2007-03-01
use. At the end of these lines, two high temperature hoses provide flexibility for connection. 57 Figure 28: Heater emergency shutoff...stainless steel braided , Teflon tubing. This enables the probe to be easily positioned as required. The oil temperature is measured by a K-type...used to cool emissions probe. The sample gases exit the probe into a 1/4” piece of braided , flexible Teflon tubing to provide for probe
Hybrid indirect/direct contactor for thermal management of counter-current processes
Hornbostel, Marc D.; Krishnan, Gopala N.; Sanjurjo, Angel
2018-03-20
The invention relates to contactors suitable for use, for example, in manufacturing and chemical refinement processes. In an aspect is a hybrid indirect/direct contactor for thermal management of counter-current processes, the contactor comprising a vertical reactor column, an array of interconnected heat transfer tubes within the reactor column, and a plurality of stream path diverters, wherein the tubes and diverters are configured to block all straight-line paths from the top to bottom ends of the reactor column.
The vagina is the female body part that connects the womb (uterus) and cervix to the outside of the ... The vagina is a muscular tube lined with mucous membranes. Its opening is between the urethra (where urine leaves ...
Plasma discharge elemental detector for a mass spectrometer
NASA Astrophysics Data System (ADS)
Heppner, R. A.
1983-06-01
A material to be analyzed is injected into a mirowave-induced plasma discharge unit, in which the material is carried with a flow of buffer gas through an intense microwave energy field which produces a plasma discharge in the buffer gas. As the material exits from the plasma discharge, the material is sampled and conveyed along a capillary transfer tube to a mass spectrometer where it is analyzed. The plasma discharge causes dissociation of complex organic molecules into simpler molecules which return to the neutral ground state before they are analyzed in the mass spectrometer. The buffer gas is supplied to one end portion of the discharge tube and is withdrawn from the other end portion by a vacuum pump which maintains a subatmospheric pressure in the discharge tube. The sample material is injected by a capillary injection tube into the buffer gas flow as it enters the plasma discharge zone. The dissociated materials are sampled by an axial sampling tube having an entrance where the buffer gas exits from the plasma discharge zone. The sample material may be supplied by a gas chromatography having a capillary effluent line connected to the capillary injection tube, so that the effluent material is injected into the microwave induced plasma discharge. The microwave field is produced by a cavity resonator through which the discharge tube passes.
Cutright, Dan; Medich, David; Ring, Joseph
2012-04-01
Eppendorf tubes often are used in biomedical research labs and contain radioactive tracers. Although the associated direct contact finger doses are typically small, it is suggested (and in line with the principle of ALARA) to handle these tubes from the cap of the tube. When containing radioactive material, handling a tube near the bottom conical section would unnecessarily increase the skin dose to the fingers. This investigation modeled a 2.0-mL Eppendorf tube containing various individual beta emitting isotopes commonly used in a biomedical research environment (i.e., (14)C, (3)H, (131)I, (32)P, and (35)S) to determine the skin dose when directly handling the tube at the cap end and when handling it at the bottom conical section. The primary goal of this paper is to assess how significantly this dose is altered by handling geometry. The skin dose to a single finger was calculated with Monte Carlo simulations using MCNP5 and determined at a depth of 0.007 cm(2) in water averaged over 10 cm as described in 10CFR20. Results show that the dose rate may vary by as much as a factor of 700 depending on handling geometry.
Rechargeable Biofilm-Controlling Tubing Materials for Use in Dental Unit Water Lines
Luo, Jie; Porteous, Nuala; Sun, Yuyu
2011-01-01
A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 inch, or 1.6 mm) to diffuse DCP into the tube’s inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications. PMID:21721534
De Waele, Michèle; Agzarian, John; Hanna, Waël C; Schieman, Colin; Finley, Christian J; Macri, Joseph; Schneider, Laura; Schnurr, Terri; Farrokhyar, Forough; Radford, Katherine; Nair, Parameswaran; Shargall, Yaron
2017-06-01
Prolonged air leak and high-volume pleural drainage are the most common causes for delays in chest tube removal following lung resection. While digital pleural drainage systems have been successfully used in the management of post-operative air leak, their effect on pleural drainage and inflammation has not been studied before. We hypothesized that digital drainage systems (as compared to traditional analog continuous suction), using intermittent balanced suction, are associated with decreased pleural inflammation and postoperative drainage volumes, thus leading to earlier chest tube removal. One hundred and three [103] patients were enrolled and randomized to either analog (n=50) or digital (n=53) drainage systems following oncologic lung resection. Chest tubes were removed according to standardized, pre-defined protocol. Inflammatory mediators [interleukin-1B (IL-1B), 6, 8, tumour necrosis factor-alpha (TNF-α)] in pleural fluid and serum were measured and analysed. The primary outcome of interest was the difference in total volume of postoperative fluid drainage. Secondary outcome measures included duration of chest tube in-situ, prolonged air-leak incidence, length of hospital stay and the correlation between pleural effusion formation, degree of inflammation and type of drainage system used. There was no significant difference in total amount of fluid drained or length of hospital stay between the two groups. A trend for shorter chest tube duration was found with the digital system when compared to the analog (P=0.055). Comparison of inflammatory mediator levels revealed no significant differences between digital and analog drainage systems. The incidence of prolonged post-operative air leak was significantly higher when using the analog system (9 versus 2 patients; P=0.025). Lobectomy was associated with longer chest tube duration (P=0.001) and increased fluid drainage when compared to sub-lobar resection (P<0.001), regardless of drainage system. Use of post-lung resection digital drainage does not appear to decrease pleural fluid formation, but is associated with decreased prolonged air leaks. Total pleural effusion volumes did not differ with the type of drainage system used. These findings support previously established benefits of the digital system in decreasing prolonged air leaks, but the advantages do not appear to extend to decreased pleural fluid formation.
Novel synthetic curcumin analogs as potent antiangiogenic agents in colorectal cancer.
Rajitha, Balney; Nagaraju, Ganji Purnachandra; Shaib, Walid L; Alese, Olatunji B; Snyder, James P; Shoji, Mamoru; Pattnaik, Subasini; Alam, Afroz; El-Rayes, Bassel F
2017-01-01
The transcription factor NF-κB plays a central role in angiogenesis in colorectal cancer (CRC). Curcumin is a natural dietary product that inhibits NF-κB. The objective of this study is to evaluate the antiangiogenic effects of curcumin and two potent synthetic analogues (EF31 and UBS109) in CRC. IC 50 values for curcumin, EF31, and UBS109 were determined in the HCT116 and HT-29 cell lines. HUVEC tube formation, egg CAM assay, and matrigel plug assays revealed decreased angiogenesis in cell lines treated with curcumin, EF31, or UBS109. Curcumin and its analogues significantly inhibited VEGF-A synthesis and secretion in both cell lines in association with loss of HIF-1α, COX-2, and p-STAT-3 expression. Nuclear NF-κB expression was inhibited by curcumin, EF31, and UBS109. Transfection of p65-NF-κB in HCT116 and HT-29 cells resulted in increased expression of HIF-1α, COX-2, STAT-3, and VEGF-A. Treatment with curcumin, EF31, or UBS109 inhibited these effects in transfected cell lines. In mice carrying HCT116 and HT-29 cell xenografts, EF31 and UBS109 inhibited subcutaneous tumor growth and potentiated the effects of oxaliplatin and 5-FU. Tumors from treated animals revealed inhibition of HIF-1α, COX-2, p-STAT-3, and VEGF expression. Our findings suggest that inhibition of NF-κB leading to decreased transcription and expression of HIF-1α, COX-2, STAT-3, and VEGF is a rational approach for antiangiogenic therapy in CRC. The distinctive properties of EF31 and UBS109 make them promising therapeutic agents for development in CRC as single agents or as part of combination chemotherapy regimens. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Koptyug, Igor V; Sagdeev, Dmitry R; Gerkema, Edo; Van As, Henk; Sagdeev, Renad Z
2005-07-01
Multidimensional images of Al2O3 pellets, cordierite monolith, glass tube, polycrystalline V2O5 and other materials have been detected by 27Al, 51V, and 23Na NMR imaging using techniques and instrumentation conventionally employed for imaging of liquids. These results demonstrate that, contrary to the widely accepted opinion, imaging of "rigid" solids does not necessarily require utilization of solid state NMR imaging approaches, pulse sequences and hardware even for quadrupolar nuclei which exhibit line widths in excess of 100 kHz, such as 51V in polycrystalline V2O5. It is further demonstrated that both 27Al NMR signal intensity and spin-lattice relaxation time decrease with increasing temperature and thus can potentially serve as temperature sensitive parameters for spatially resolved NMR thermometry.
NASA Astrophysics Data System (ADS)
Nieschke, Kathleen; Mittag, Anja; Golab, Karolina; Bocsi, Jozsef; Pierzchalski, Arkadiusz; Kamysz, Wojciech; Tarnok, Attila
2014-03-01
Toxicity test of new chemicals belongs to the first steps in the drug screening, using different cultured cell lines. However, primary human cells represent the human organism better than cultured tumor derived cell lines. We developed a very gentle toxicity assay for isolation and incubation of human peripheral blood leukocytes (PBL) and tested it using different bioactive oligopeptides (OP). Effects of different PBL isolation methods (red blood cell lysis; Histopaque isolation among others), different incubation tubes (e.g. FACS tubes), anticoagulants and blood sources on PBL viability were tested using propidium iodide-exclusion as viability measure (incubation time: 60 min, 36°C) and flow cytometry. Toxicity concentration and time-depended effects (10-60 min, 36 °C, 0-100 μg /ml of OP) on human PBL were analyzed. Erythrocyte lysis by hypotonic shock (dH2O) was the fastest PBL isolation method with highest viability (>85%) compared to NH4Cl-Lysis (49%). Density gradient centrifugation led to neutrophil granulocyte cell loss. Heparin anticoagulation resulted in higher viability than EDTA. Conical 1.5 mL and 2 mL micro-reaction tubes (both polypropylene (PP)) had the highest viability (99% and 97%) compared to other tubes, i.e. three types of 5.0 mL round-bottom tubes PP (opaque-60%), PP (blue-62%), Polystyrene (PS-64%). Viability of PBL did not differ between venous and capillary blood. A gentle reproducible preparation and analytical toxicity-assay for human PBL was developed and evaluated. Using our assay toxicity, time-course, dose-dependence and aggregate formation by OP could be clearly differentiated and quantified. This novel assay enables for rapid and cost effective multiparametric toxicological screening and pharmacological testing on primary human PBL and can be adapted to high-throughput-screening.°z
Losada, Juan M; Herrero, Maria
2017-04-01
Within the ovary, the obturator bridges the pathway of the pollen tube from the style to the ovule. Despite its widespread presence among flowering plants, its function has only been studied in a handful of species, and the molecules involved in pollen tube-obturator cross-talk have not been explored hitherto. This work evaluates the involvement of glucans and glycoproteins on pollen tube growth in the obturator of apple flowers ( Malus × domestica) . Pollen tube kinetics were sequentially examined in the pistil and related to changes occurring on the obturator using histochemistry and inmunocytochemistry. To discriminate between changes in the obturator induced by pollen tubes from those developmentally regulated, both pollinated and unpollinated pistils were examined. Pollen tube growth rates were slow in the stigma, faster in the style and slow again in the ovary. The arrival of pollen tubes at the obturator was concomitant with the secretion of proteins, saccharides and glycoprotein epitopes belonging to extensins and arabinogalactan proteins (AGPs). While some of these secretions - extensins and AGPs labelled by JIM13 - were developmentally regulated, others - AGPs labelled by JIM8 - were elicited by the presence of pollen tubes. Following pollen tube passage, all these glycoproteins were depleted. The results show a timely secretion of glycoproteins on the obturator surface concomitant with pollen tube arrival at this structure. The fact that their secretion is depleted following pollen tube passage strongly suggests their role in regulating pollen tube access to the ovule. Remarkably, both the regulation of the secretion of the different glycoproteins, as well as their association with the performance of pollen tubes exhibit similarities with those observed in the stigma, in line with their common developmental origin. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Preservative loss from silicone tubing during filling processes.
Saller, Verena; Matilainen, Julia; Rothkopf, Christian; Serafin, Daniel; Bechtold-Peters, Karoline; Mahler, Hanns-Christian; Friess, Wolfgang
2017-03-01
Significant loss of preservative was observed during filling of drug products during filling line stops. This study evaluated the losses of three commonly used preservatives in protein drugs, i.e. benzyl alcohol, phenol, and m-cresol. Concentration losses during static incubation were quantified and interpreted with regard to the potential driving forces for the underlying sorption, diffusion, and desorption steps. Partitioning from the solution into the silicone polymer was identified as the most decisive parameter for the extent of preservative loss. Additionally, the influence of tubing inner diameter, starting concentration as well as silicone tubing type was evaluated. Theoretical calculations assuming equilibrium between solution and tubing inner surface and one-directional diffusion following Fick's first law were used to approximate experimental data. Since significant losses were found already after few minutes, adequate measures must be taken to avoid deviations during filling of preservative-containing protein solutions that may impact product quality or antimicrobial efficacy. As a possible alternative to the highly permeable silicone tubing, a specific make of fluoropolymer tubing was identified being suitable for peristaltic pumps and not showing any preservative losses. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Lingtong; Zheng, Canhui; Kuang, Baijan; Wei, Liqin; Yan, Longfeng; Wang, Tai
2016-01-01
During sexual reproduction of flowering plants, the pollen tube grows fast and over a long distance within the pistil to deliver two sperms for double fertilization. Growing plant cells need to communicate constantly with external stimuli as well as monitor changes in surface tension of the cell wall and plasma membrane to coordinate these signals and internal growth machinery; however, the underlying mechanisms remain largely unknown. Here we show that the rice member of plant-specific receptor-like kinase CrRLK1Ls subfamily, Ruptured Pollen tube (RUPO), is specifically expressed in rice pollen. RUPO localizes to the apical plasma membrane and vesicle of pollen tubes and is required for male gamete transmission. K+ levels were greater in pollen of homozygous CRISPR-knockout lines than wild-type plants, and pollen tubes burst shortly after germination. We reveal the interaction of RUPO with high-affinity potassium transporters. Phosphorylation of RUPO established and dephosphorylation abolished the interaction. These results have revealed the receptor-like kinase as a regulator of high-affinity potassium transporters via phosphorylation-dependent interaction, and demonstrated a novel receptor-like kinase signaling pathway that mediates K+ homeostasis required for pollen tube growth and integrity. PMID:27447945
Leakage of fluid in different types of tracheal tubes.
Winklmaier, U; Wüst, K; Schiller, S; Wallner, F
2006-10-01
The aim of this study was to evaluate leakage of liquids, i.e., water and saliva, past low-pressure cuffs of tracheostomy tubes. Three different types of tracheostomy tubes, TRACOE vario (TRACOE Medical GmbH, Germany), Rüsch Ultra-Tracheoflex (Rüsch GmbH, Germany), and Portex Blue Line Ultra (Smiths Medical, UK) were tested in isolated pig tracheas. Sixty samples (10 tubes each of 7- and 8-mm inner diameter of each type) were used. Four different experiments were devised: type 1 (water and artificial ventilation), type 2 (water and no artificial ventilation), type 3 (saliva and artificial ventilation), and type 4 (saliva and no artificial ventilation). Six milliliters of water or artificial saliva were infused over the cuff and the volume of fluid that leaked past the cuff was measured after 5, 10, and 15 min. Intracuff pressure was also measured three times. The saliva experiments resulted in less leakage than the water experiments. Leakage after treatment with water or artificial saliva is higher without artificial ventilation than with ventilation. The amount of leakage among the tubes with respect to manufacturer showed statistically significant results. However, there were no differences among tracheostomy tubes with respect to internal diameter.
NASA Astrophysics Data System (ADS)
Powell, J. G.
1990-07-01
A nuclear qualified in-containment electrical connection is presented that comprises: (1) an insulated, sheathed instrument lead having electrical conductors extending from one end thereof to provide two exposed lead wires; (2) a watertight cable having electrical conducting wires therein and extending from one end of the cable to provide two lead wires therefrom; (3) two butt splice connectors each connecting the ends of respective ones of the lead wires from the instrument lead and cable; (4) a length of heat shrinkable plastic tubing positioned over each butt splice connector and an adjacent portion of a respective lead wire from the cable and heat shrunk into position; and (5) a length of heat shrinkable plastic tubing on the end portion of the instrument lead adjacent the lead wires therefrom, heat shrunk thereon, with a length of outer heat shrinkable plastic tubing. The plastic tubing extends over the end portion of the instrument lead and the heat shrinkable tubing and over the butt splice connectors and a portion of the cable adjacent the cable lead lines. The outer heat shrinkable tubing is heat shrunk into sealing position on the instrument lead and cable.
46 CFR 56.50-70 - Gasoline fuel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (1) Fuel supply piping to the engines shall be of seamless drawn annealed copper pipe or tubing... sharp edges. Where passing through steel decks or bulkheads, fuel lines shall be protected by close...
46 CFR 56.50-70 - Gasoline fuel systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... (1) Fuel supply piping to the engines shall be of seamless drawn annealed copper pipe or tubing... sharp edges. Where passing through steel decks or bulkheads, fuel lines shall be protected by close...
46 CFR 56.50-70 - Gasoline fuel systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... (1) Fuel supply piping to the engines shall be of seamless drawn annealed copper pipe or tubing... sharp edges. Where passing through steel decks or bulkheads, fuel lines shall be protected by close...
46 CFR 56.50-70 - Gasoline fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... (1) Fuel supply piping to the engines shall be of seamless drawn annealed copper pipe or tubing... sharp edges. Where passing through steel decks or bulkheads, fuel lines shall be protected by close...
46 CFR 56.50-70 - Gasoline fuel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (1) Fuel supply piping to the engines shall be of seamless drawn annealed copper pipe or tubing... sharp edges. Where passing through steel decks or bulkheads, fuel lines shall be protected by close...
A pulse-tube refrigerator using variable-resistance orifice
NASA Astrophysics Data System (ADS)
Huang, B. J.; Sun, B. W.
2003-01-01
In the present study, we propose a new design of orifice pulse-tube refrigerator (VROPT) using a variable-resistance valve to replace the conventional orifice. The variable-resistance orifice (VRO) is basically a high-speed solenoidal valve similar to the fuel jet device widely used in automobile engines. By changing the frequency and periods of ON and OFF of the valve through an electronic device, we can change the flow resistance of the VRO. This thus provides a possibility for an OPT to be controlled on-line during operation. From the results obtained in the present study, we have shown that VROPT is able to achieve on-line control by regulating the duty cycle d or frequency fv of the VRO. We also show that VROPT will not loss its thermal performance as compared to conventional OPT.
Water Relations, Gas Exchange, and Nutrient Response to a Long Term Constant Water Deficit
NASA Technical Reports Server (NTRS)
Berry, Wade L.; Goldstein, Guillermo; Dreschel, Thomas W.; Wheeler, Raymond M.; Sager, John C.; Knott, William M.
1992-01-01
Wheat plants (Triticum aestivum) were grown for 43 days in a micro-porous tube nutrient delivery system. Roots were unable to penetrate the microporous tube, but grew on the surface and maintained capillary contact with the nutrient solution on the inside of the tube through the 5-micron pores of the porous tube. Water potential in the system was controlled at -0.4, -0.8, and -3.0 kPa by adjusting the applied pressure (hydrostatic head) to the nutrient solution flowing through the microporous tubes. A relatively small decrease in applied water potential from -0.4 to -3.0 kPa resulted in a 34% reduction of shoot growth but only a moderate reduction in the midday leaf water potential from -1.3 to -1.7 MPa. Carbon dioxide assimilation decreased and water use efficiency increased with the more negative applied water potentials, while intercellular CO2 concentration remained constant. This was associated with a decrease in stomatal conductance to water vapor from 1.90 to 0.98 mol/(sq m sec) and a decrease in total apparent hydraulic conductance from 47 to 12 (micro)mol/(sec MPa). Although the applied water potentials were in the -0.4 to -3.0 kPa range, the actual water potential perceived by the plant roots appeared to be in the range of -0.26 to -0.38 MPa as estimated by the leaf water potential of bagged plants. The amount of K, Ca, Mg, Zn, Cu, and B accumulated with each unit of transpired water increased as the applied water potential became less negative. The increase in accumulation ranged from 1.4-fold for K to 2.2-fold for B. The physiological responses observed in this study in response to small constant differences in applied water potentials were much greater than expected from either the applied water potential or the observed plant water potential. Even though the micro-porous tube may not represent natural conditions and could possibly introduce morphological and physiological artifacts, it enables a high degree of control of water potential that facilitates the investigation of many aspects of water relations not practical with other experimental systems.
Non-intrusive ultrasonic liquid-in-line detector for small diameter tubes
Piper, Thomas C.
1982-01-01
An arrangement for deleting liquid in a line, using non-intrusive ultrasonic techniques is disclosed. In this arrangement, four piezoelectric crystals are arranged in pairs about a 0.072 inch o.d. pipe. An ultrasonic tone burst is transmitted along the pipe, between crystal pairs, and the amplitude of the received tone burst indicates the absence/presence of liquid in the pipe.
Non-intrusive ultrasonic liquid-in-line detector for small diameter tubes. [Patent application
Piper, T.C.
1980-09-24
An arrangement for detecting liquids in a line, using non-intrusive ultrasonic techniques is disclosed. In this arrangement, four piezoelectric crystals are arranged in pairs about a 0.078 inch o.d. pipe. An ultrasonic tone burst is transmitted along the pipe, between crystal pairs, and the amplitude of the received tone burst indicates the absence/presence of liquid in the pipe.
Engineering of multi-segmented light tunnel and flattop focus with designed axial lengths and gaps
NASA Astrophysics Data System (ADS)
Yu, Yanzhong; Huang, Han; Zhou, Mianmian; Zhan, Qiwen
2018-01-01
Based on the radiation pattern from a sectional-uniform line source antenna, a three-dimensional (3D) focus engineering technique for the creation of multi-segmented light tunnel and flattop focus with designed axial lengths and gaps is proposed. Under a 4Pi focusing system, the fields radiated from sectional-uniform magnetic and electromagnetic current line source antennas are employed to generate multi-segmented optical tube and flattop focus, respectively. Numerical results demonstrate that the produced light tube and flattop focus remain homogeneous along the optical axis; and their lengths of the nth segment and the nth gap between consecutive segments can be easily adjusted and only depend on the sizes of the nth section and the nth blanking between adjacent sectional antennas. The optical tube is a pure azimuthally polarized field but for the flattop focus the longitudinal polarization is dominant on the optical axis. To obtain the required pupil plane illumination for constructing the above focal field with prescribed characteristics, the inverse problem of the antenna radiation field is solved. These peculiar focusing fields might find potential applications in multi-particle acceleration, multi-particle trapping and manipulation.
Triggers and Manifestations of Flare Energy Release in the Low Atmosphere
NASA Astrophysics Data System (ADS)
Kosovichev, A. G.; Sharykin, I. N.; Sadykov, V. M.; Vargas, S.; Zimovets, I. V.
2016-12-01
The main goal is to understand triggers and manifestations of the flare energy release in the lower layers of the solar atmosphere (the photosphere and chromosphere) using high-resolution optical observations and magnetic field measurements. As a case study we present results for an M-class flare. We analyze optical images, HMI Dopplergrams and vector magnetograms, and use Non-Linear Force-Free Field (NLFFF) extrapolation for reconstruction of the magnetic topology. The NLFFF modelling reveals interaction of oppositely directed magnetic flux-tubes in the Polarity Inversion Line (PIL). These two interacting magnetic flux tubes are observed as a compact sheared arcade along the PIL in the high-resolution broad-band continuum images from New Solar Telescope (NST). In the vicinity of the PIL, the NST H-alpha observations reveal formation of a thin three-ribbon structure corresponding to the small-scale photospheric magnetic arcade. Magnetic reconnection is triggered by two interacting magnetic flux tubes with forming current sheet extended along the PIL. Presented observational results evidence in favor of location of the primary energy release site in the dense chromosphere where plasma is partially ionized in the region of strong electric currents concentrated near the polarity inversion line.
Liquid scintillation sample analysis in microcentrifuge tubes.
Elliott, J C
1993-01-01
Local regulations prohibiting drain disposal of "biodegradable" liquid scintillation cocktails prompted investigation of volume reduction for these materials. Microcentrifuge tubes were used with aqueous and filter media samples of 3H, 14C, 32P, and 125I. Backgrounds, counting efficiencies, figures of merit, and spectral distributions obtained for microcentrifuge tubes compared favorably to conventional vials. Differences in 32P spectra for solid support samples appeared related to filter material and sample volume. Decreases in sample costs and waste volume and disposal costs were approximately 50-75%.
Analysis of a deflating soap bubble
NASA Astrophysics Data System (ADS)
Jackson, David P.; Sleyman, Sarah
2010-10-01
A soap bubble on the end of a cylindrical tube is seen to deflate as the higher pressure air inside the bubble escapes through a tube. We perform an experiment to measure the radius of the slowly deflating bubble and observe that the radius decreases to a minimum before quickly increasing. This behavior reflects the fact that the bubble ends up as a flat surface over the end of the tube. A theoretical analysis reproduces this behavior and compares favorably with the experimental data.
Performance of three systems for warming intravenous fluids at different flow rates.
Satoh, J; Yamakage, M; Wasaki, S I; Namiki, A
2006-02-01
This study compared the intravenous fluid warming capabilities of three systems at different flow rates. The devices studied were a water-bath warmer, a dry-heat plate warmer, and an intravenous fluid tube warmer Ambient temperature was controlled at 22 degrees to 24 degrees C. Normal saline (0.9% NaCl) at either room temperature (21 degrees to 23 degrees C) or at ice-cold temperature (3 degrees to 5 degrees C) was administered through each device at a range of flow rates (2 to 100 ml/min). To mimic clinical conditions, the temperature of the fluid was measured with thermocouples at the end of a one metre tube connected to the outflow of the warmer for the first two devices and at the end of the 1.2 m warming tubing for the intravenous fluid tube warmer The temperature of fluid delivered by the water bath warmer increased as the flow rate was increased up to 15 to 20 ml/min but decreased with greater flow rates. The temperature of the fluid delivered by the dry-heat plate warmer significantly increased as the flow rate was increased within the range tested (due to decreased cooling after leaving the device at higher flow rates). The temperature of fluid delivered by the intravenous fluid tube warmer did not depend on the flow rate up to 20 ml/min but significantly and fluid temperature-dependently decreased at higher flow rates (>30 ml/min). Under the conditions of our testing, the dry heat plate warmer delivered the highest temperature fluid at high flow rates.
Transpyloric Feeding Tube Placement Using Electromagnetic Placement Device in Children.
Goggans, Margaret; Pickard, Sharon; West, Alina Nico; Shah, Samir; Kimura, Dai
2017-04-01
Transpyloric feeding tubes (TPT) are often recommended in critically ill children. Blind tube placement, however, can be difficult, be time-consuming, and incur multiple radiation exposures. An electromagnetic device (EMD) is available for confirmation of successful placement of TPTs. We conducted a retrospective cohort study to evaluate the efficacy of an EMD for TPT placement in children and determine its impact on placement success, radiation exposure, confirmation time, and cost for tube placement compared with traditional blind TPT placement. Retrospective data were collected in patients receiving a TPT before (pre-EMD group) and after implementation of an EMD (EMD group). Need for radiographic exposure decreased significantly in the EMD group (n = 40) compared with the pre-EMD group (n = 38) (0.6 vs 1.6 x-rays, P < .001). TPTs were placed and confirmed without abdominal x-ray in 21 of 40 patients in the EMD group. There were no serious adverse events such as misplacement into the lung or pneumothorax or perforation injury of the stomach. Successful tube confirmation took a significantly shorter time in the EMD group than in the pre-EMD group (1.45 vs 4.59 hours, P < .0001). There was an estimated cost savings of $245.10 per placement associated with decreased x-ray and fluoroscopy. The use of an EMD in children significantly decreased radiation exposure and confirmation time while maintaining TPT placement success. The use of an EMD can potentially offer large cost savings. Elimination of abdominal x-ray with EMD during TPT placement was achieved without any serious complications in approximately half of the children.
Research on Annular Frictional Pressure Loss of Hydraulic-Fracturing in Buckling Coiled Tubing
NASA Astrophysics Data System (ADS)
Liu, Bin; Cai, Meng; Li, Junliang; Xu, Yongquan; Wang, Peng
2018-01-01
Compared with conventional hydraulic fracturing, coiled tubing (CT) annular delivery sand fracturing technology is a new method to enhance the recovery ratio of low permeability reservoir. Friction pressure loss through CT has been a concern in fracturing. The small diameter of CT limits the cross-sectional area open to flow, therefore, to meet large discharge capacity, annular delivery sand technology has been gradually developed in oilfield. Friction pressure is useful for determining the required pump horsepower and fracturing construction design programs. Coiled tubing can buckle when the axial compressive load acting on the tubing is greater than critical buckling load, then the geometry shape of annular will change. Annular friction pressure loss elevates dramatically with increasing of discharge capacity, especially eccentricity and CT buckling. Despite the frequency occurrence of CT buckling in oilfield operations, traditionally annular flow frictional pressure loss considered concentric and eccentric annuli, not discussing the effects of for discharge capacity and sand ratio varying degree of CT buckling. The measured data shows that the factors mentioned above cannot be ignored in the prediction of annular pressure loss. It is necessary to carry out analysis of annulus flow pressure drop loss in coiled tubing annular with the methods of theoretical analysis and numerical simulation. Coiled tubing buckling has great influence on pressure loss of fracturing fluid. Therefore, the correlations have been developed for turbulent flow of Newtonian fluids and Two-phase flow (sand-liquid), and that improve the friction pressure loss estimation in coiled tubing operations involving a considerable level of buckling. Quartz sand evidently increases pressure loss in buckling annular, rising as high as 40%-60% more than fresh water. Meanwhile, annulus flow wetted perimeter increases with decreasing helical buckling pitch of coiled tubing, therefore, the annulus flow frictional pressure loss rapidly increases with decreasing helical buckling pitch. The research achievement provides theoretical guidance for coiled tubing annular delivery sand fracturing operation and design.
Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo
2016-01-01
We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01). Compared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
de Abreu, Emanuelle Maria Sávio; Machado, Carla Jorge; Pastore Neto, Mario; de Rezende Neto, João Baptista; Sanches, Marcelo Dias
2015-01-01
to investigate the effect of standardized interventions in the management of tube thoracostomy patients and to assess the independent effect of each intervention. A chest tube management protocol was assessed in a retrospective cohort study. The tube thoracostomy protocol (TTP) was implemented in August 2012, and consisted of: antimicrobial prophylaxis, chest tube insertion in the operating room (OR), admission post chest tube thoracostomy (CTT) in a hospital floor separate from the emergency department (ED), and daily respiratory therapy (RT) sessions post-CTT. The inclusion criteria were, hemodynamic stability, patients between the ages of 15 and 59 years, and injury severity score (ISS) < 17. All patients had isolated injuries to the chest wall, lung, and pleura. During the study period 92 patients were managed according to the standardized protocol. The outcomes of those patients were compared to 99 patients treated before the TTP. Multivariate logistic regression analysis was performed to assess the independent effect of each variable of the protocol on selected outcomes. Demographics, injury severity, and trauma mechanisms were similar among the groups. As expected, protocol compliance increased after the implementation of the TTP. There was a significant reduction (p<0.05) in the incidence of retained hemothoraces, empyemas, pneumonias, surgical site infections, post-procedural complications, hospital length of stay, and number of chest tube days. Respiratory therapy was independently linked to significant reduction (p<0.05) in the incidence of seven out of eight undesired outcomes after CTT. Antimicrobial prophylaxis was linked to a significant decrease (p<0.05) in retained hemothoraces, despite no significant (p<0.10) reductions in empyema and surgical site infections. Conversely, OR chest tube insertion was associated with significant (p<0.05) reduction of both complications, and also significantly decreased the incidence of pneumonias. Implementation of a TTP effectively reduced complications after CTT in trauma patients.
Adsorption of multilamellar tubes with a temperature tunable diameter at the air/water interface.
Fameau, Anne-Laure; Douliez, Jean-Paul; Boué, François; Ott, Frédéric; Cousin, Fabrice
2011-10-15
The ethanolamine salt of 12-hydroxy stearic acid is known to form tubes having a temperature tunable diameter. Here, we study the behavior of those tubes at the air/water interface by using Neutron Reflectivity. We observed that tubes indeed adsorbed at this interface below a fatty acid monolayer and exhibit the same temperature behavior as in bulk. There is however a peculiar behavior at around 50 °C for which the increase of the diameter of the tubes at the interface yields an unfolding of those tubes into a multilamellar layer. Upon further heating, the tubes re-fold and their diameter re-decreases after which they melt into micelles as observed in the bulk. All structural transitions at the interface are nevertheless reversible. This provides to the system a high interest for its interfacial properties because the structure at the air/water interface can be tuned easily by the temperature. Copyright © 2011 Elsevier Inc. All rights reserved.
García-Fragoso, Lourdes; García-García, Inés; de la Vega, Alberto; Renta, Jessicca; Cadilla, Carmen L
2002-01-01
Folic acid supplementation can reduce the incidence of neural tube defects. The first reported genetic risk factor for neural tube defects is a C677T mutation in the 5,10-methylenetetrahydrofolate reductase gene, resulting in decreased activity of the enzyme. We examined the enzyme mutation role of methylenetetrahydrofolate reductase in the etiology of neural tube defects in our population. The study group consisted of 204 Puerto Rican individuals including 37 pregnant females with a prenatal diagnosis of neural tube defects in their fetuses, 31 newborns, 36 fathers, and 100 healthy adults. The prevalence of the C677T mutation was examined. Homozygosity for the alanine to valine substitution (TT) was observed in 9% of the controls and 19% of the mothers with children with neural tube defects. Our results indicate that the presence of the T allele at the methylenetetrahydrofolate reductase 677 position may increase the risk of giving birth to an infant with a neural tube defect.
NASA Astrophysics Data System (ADS)
Kim, Nae-Hyun
2016-12-01
R-410A condensation heat transfer and pressure drop data are provided for a 7.0 mm O.D. microfin tube at low mass fluxes (50-250 kg/m2 s). The heat transfer coefficient of the microfin tube shows a minimum behavior with the mass flux. At a low mass flux, where flow pattern is stratified, condensation induced by surface tension by microfins overwhelms condensation induced by shear, and the heat transfer coefficient decreases as mass flux increases. At a high mass flux, where flow pattern is annular, condensation induced by shear governs the heat transfer, and the heat transfer coefficient increases as mass flux increases. The pressure drop of the microfin tube is larger than that of the smooth tube at the annular flow regime. On the contrary, the pressure drop of the smooth tube is larger than that of the microfin tube at the stratified flow regime.
Myelin structures formed by thermotropic smectic liquid crystals
NASA Astrophysics Data System (ADS)
Peddireddy, Karthik Reddy; Kumar, Pramoda; Thutupalli, Shashi; Herminghaus, Stephan; Bahr, Christian
2014-03-01
We report on transient structures, formed by thermotropic smectic-A liquid crystals, resembling the myelin figures of lyotropic lamellar liquid crystals. The thermotropic myelin structures form during the solubilization of a smectic-A droplet in an aqueous phase containing a cationic surfactant at concentrations above the critical micelle concentration. Similar to the lyotropic myelin figures, the thermotropic myelins appear in an optical microscope as flexible tube-like structures growing at the smectic/aqueous interface. Polarizing microscopy and confocal fluorescence microscopy show that the smectic layers are parallel to the tube surface and form a cylindrically bent arrangement around a central line defect in the tube. We study the growth behavior of this new type of myelins and discuss similarities and differences to the classical lyotropic myelin figures.
Raytheon Stirling/pulse Tube Cryocooler Development
NASA Astrophysics Data System (ADS)
Kirkconnell, C. S.; Hon, R. C.; Kesler, C. H.; Roberts, T.
2008-03-01
The first generation flight-design Stirling/pulse tube "hybrid" two-stage cryocooler has entered initial performance and environmental testing. The status and early results of the testing are presented. Numerous improvements have been implemented as compared to the preceding brassboard versions to improve performance, extend life, and enhance launch survivability. This has largely been accomplished by incorporating successful flight-design features from the Raytheon Stirling one-stage cryocooler product line. These design improvements are described. In parallel with these mechanical cryocooler development efforts, a third generation electronics module is being developed that will support hybrid Stirling/pulse tube and Stirling cryocoolers. Improvements relative to the second generation design relate to improved radiation hardness, reduced parts count, and improved vibration cancellation capability. Progress on the electronics is also presented.
Experimental Investigation on the Resonance of a Liquid Column in a Capillary Tube.
Hilpert; Miller
1999-11-01
Using a visualization technique, we observed the resonance of a water column trapped in a vertically oriented capillary tube due to acoustic excitation. The analysis of the quasi-static response suggests that the upper nonvisible meniscus followed the imposed flow by means of a sliding contact line without changing its shape. We compared the experiments with a previously developed theoretical model that addresses dissipation by assuming an axially symmetric and incompressible flow field that is spatially constant along the tube axis. Whereas the model agrees well with the measured quasi-static response, the deviations in the dynamic response reveal shortcomings of the model due to the simplified treatment of the viscous dissipation. Copyright 1999 Academic Press.
ATLS: Catheter and tube placement
NASA Technical Reports Server (NTRS)
Gosbee, John; Krupa, Debra T.; Pepper, L.; Orsak, Debra
1991-01-01
The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.
Imaging Fluorescent Combustion Species in Gas Turbine Flame Tubes: On Complexities in Real Systems
NASA Technical Reports Server (NTRS)
Hicks, Y. R.; Locke, R. J.; Anderson, R. C.; Zaller, M.; Schock, H. J.
1997-01-01
Planar laser-induced fluorescence (PLIF) is used to visualize the flame structure via OH, NO, and fuel imaging in kerosene- burning gas turbine combustor flame tubes. When compared to simple gaseous hydrocarbon flames and hydrogen flames, flame tube testing complexities include spectral interferences from large fuel fragments, unknown turbulence interactions, high pressure operation, and the concomitant need for windows and remote operation. Complications of these and other factors as they apply to image analysis are considered. Because both OH and gas turbine engine fuels (commercial and military) can be excited and detected using OH transition lines, a narrowband and a broadband detection scheme are compared and the benefits and drawbacks of each method are examined.
Ovarian Epithelial Inclusions With Mucinous Differentiation: A Clinicopathologic Study of 42 Cases.
Seidman, Jeffrey D; Krishnan, Jayashree
2017-07-01
Ovarian epithelial inclusions lined by mucinous epithelium are rare and of uncertain origin. Ovaries containing such inclusions were studied in 42 women. The inclusions were divided into 3 groups: serous epithelial lined with typical ciliated morphology but with distinct basophilic cytoplasmic mucin in some or all of the lining cells, those lined by typical mucinous epithelium, and those lined by a combination of typical mucinous epithelium and serous epithelium. The mean patient age was 61.5 years. Pure mucinous inclusions were found in 27 patients, serous-type inclusions with cytoplasmic mucin in 20, and mixed type in 10. All 3 types of inclusions were found in 1 patient. Two types of inclusions were found in 13. Four patients had associated mucinous neoplasms (1 mucinous cystadenoma, 1 atypical proliferative seromucinous tumor, and 2 seromucinous cystadenomas), and 11 patients (26%) had endometriosis. The fallopian tubes in 4 patients (9.5%) also displayed mucinous metaplasia; this was not significantly different from the 3.1% we found in our previously reported series of unselected tubes from the same population. These findings suggest that mucinous inclusions may arise as a direct metaplastic change in serous-type inclusions. Other possible origins of mucinous inclusions in the ovarian cortex include endometriosis and Brenner (transitional cell) nests. Whether such inclusions can be a source of mucinous ovarian neoplasms as are Brenner tumors and mature cystic teratomas is unknown and may warrant further investigation.
Study of nitrogen flowing afterglow with mercury vapor injection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazánková, V., E-mail: mazankova@fch.vutbr.cz; Krčma, F.; Trunec, D.
2014-10-21
The reaction kinetics in nitrogen flowing afterglow with mercury vapor addition was studied by optical emission spectroscopy. The DC flowing post-discharge in pure nitrogen was created in a quartz tube at the total gas pressure of 1000 Pa and discharge power of 130 W. The mercury vapors were added into the afterglow at the distance of 30 cm behind the active discharge. The optical emission spectra were measured along the flow tube. Three nitrogen spectral systems – the first positive, the second positive, and the first negative, and after the mercury vapor addition also the mercury resonance line at 254more » nm in the spectrum of the second order were identified. The measurement of the spatial dependence of mercury line intensity showed very slow decay of its intensity and the decay rate did not depend on the mercury concentration. In order to explain this behavior, a kinetic model for the reaction in afterglow was developed. This model showed that the state Hg(6 {sup 3}P{sub 1}), which is the upper state of mercury UV resonance line at 254 nm, is produced by the excitation transfer from nitrogen N{sub 2}(A{sup 3}Σ{sup +}{sub u}) metastables to mercury atoms. However, the N{sub 2}(A{sup 3}Σ{sup +}{sub u}) metastables are also produced by the reactions following the N atom recombination, and this limits the decay of N{sub 2}(A{sup 3}Σ{sup +}{sub u}) metastable concentration and results in very slow decay of mercury resonance line intensity. It was found that N atoms are the most important particles in this late nitrogen afterglow, their volume recombination starts a chain of reactions which produce excited states of molecular nitrogen. In order to explain the decrease of N atom concentration, it was also necessary to include the surface recombination of N atoms to the model. The surface recombination was considered as a first order reaction and wall recombination probability γ = (1.35 ± 0.04) × 10{sup −6} was determined from the experimental data. Also sensitivity analysis was applied for the analysis of kinetic model in order to reveal the main control parameters in the model.« less
Xia, Yu-Fang; Pei, Gui-Hua; Wang, Ning; Che, Yan-Ci; Yu, Feng-Sheng; Yin, Fu-Fen; Liu, Hai-Xia; Luo, Bing; Wang, Yan-Kui
2017-02-04
Cervical cancer (CC) is the second most common cancer in females in developing countries. The two viral oncoproteins E6 and E7 mediate the oncogenic activities of high-risk human papillomavirus (HR-HPV), and HR-HPV, especially HPV16 or/and HPV18 (HPV16/18) play critical roles in CC through different pathways. microRNAs (miRNAs) may be associated with CC pathogenesis. Researches have indicated that human papillomavirus (HPV) may regulate cellular miRNA expression through viral E6 and E7. Herein, the purposes of this study were to identify the relationship between HPV infection and aberrantly expressed miRNAs and to investigate their pathogenic roles in CC. miRNA expression was assessed using a microRNAs microarray in HPV16 E6- and E7-integrated HPV-negative HT-3 cell lines and mock vector-transfected HT-3 cells. The microarray results were validated, and the expression of miR-3156-3p was identified in HPV-positive and -negative CC cell lines as well as primary CC and normal cervical epithelium tissues using quantitative reverse-transcription polymerase chain reaction (qRT-PCR). Cell Counting Kit-8 (CCK8), flow cytometry, transwell analysis, tube formation, and Western blotting were used to identify the functional role of miR-3156-3p in CaSki, SiHa, and HeLa cell lines. Six underexpressed microRNAs (miR-3156-3p, 6779-3p, 4779-3p, 6841-3p, 454-5p and 656-5p) were consistently identified in HPV16 E6- and E7-integrated HT-3 cells. Further investigation confirmed a significant decrease of miR-3156-3p in HPV16/18 positive CC lesions. CCK8, flow cytometry, transwell analysis, tube formation assays, and Western blotting of the CC cell lines with miR-3156-3p over/under-expression in vitro showed that miR-3156-3p was involved in cell proliferation, apoptosis, migration, neovascularization, and SLC6A6 regulation. Our findings indicate that miR-3156-3p plays a suppressor-miRNA role in CC and that its expression is associated with HR-HPV infection.
Li, Xue; Tang, Jingyu; Bao, Luhan; Chen, Lin; Hong, Feng F
2017-12-15
In order to improve property of bacterial nano-cellulose (BNC) to achieve the requirements of clinical application as small caliber vascular grafts, chitosan (CH) was deposited into the fibril network of the BNC tubes fabricated in unique Double-Silicone-Tube bioreactors. Heparin (Hep) was then chemically grafted into the BNC-based tubes using EDC/NHS crosslinking to improve performance of anticoagulation and endothelialization. Physicochemical and mechanical property, blood compatibility, and cytocompatibility were compared before and after compositing. The results indicated that strength at break was increased but burst pressure decreased slightly after compositing. Performance of the BNC tubes was improved remarkably after introducing chitosan and heparin. The EDC/NHS crosslinking catalyzed both amide bonds and ester bonds formation in the BNC/CH-Hep composites. Three-dimensional surface structure and roughness were firstly obtained and discussed in relation to the hemocompatibility of BNC-based tubes. This work demonstrates the heparinized BNC-based tubes have great potential in application as small-diameter vascular prosthesis. Copyright © 2017 Elsevier Ltd. All rights reserved.
Magnetic shuffling of coronal downdrafts
NASA Astrophysics Data System (ADS)
Petralia, A.; Reale, F.; Orlando, S.
2017-02-01
Context. Channelled fragmented downflows are ubiquitous in magnetized atmospheres, and have recently been addressed based on an observation after a solar eruption. Aims: We study the possible back-effect of the magnetic field on the propagation of confined flows. Methods: We compared two 3D magnetohydrodynamic simulations of dense supersonic plasma blobs that fall down along a coronal magnetic flux tube. In one, the blobs move strictly along the field lines; in the other, the initial velocity of the blobs is not perfectly aligned with the magnetic field and the field is weaker. Results: The aligned blobs remain compact while flowing along the tube, with the generated shocks. The misaligned blobs are disrupted and merge through the chaotic shuffling of the field lines. They are structured into thinner filaments. Alfvén wave fronts are generated together with shocks ahead of the dense moving front. Conclusions: Downflowing plasma fragments can be chaotically and efficiently mixed if their motion is misaligned with field lines, with broad implications for disk accretion in protostars, coronal eruptions, and rain, for example. Movies associated to Figs. 2 and 3 are available at http://www.aanda.org
Simulation-Based Mastery Learning Improves Central Line Maintenance Skills of ICU Nurses.
Barsuk, Jeffrey H; Cohen, Elaine R; Mikolajczak, Anessa; Seburn, Stephanie; Slade, Maureen; Wayne, Diane B
2015-10-01
This study evaluated the impact of a simulation-based mastery learning (SBML) curriculum on central line maintenance and care among a group of ICU nurses. The intervention included 5 tasks: (a) medication administration, (b) injection cap (needleless connector) changes, (c) tubing changes, (d) blood drawing, and (e) dressing changes. All participants underwent a pretest, engaged in deliberate practice with directed feedback, and completed a posttest. We compared pretest and posttest scores and assessed correlations between demographics, self-confidence, and pretest performance. The number of nurses passing each task at pretest varied from 24 of 49 (49%) for dressing changes to 44 of 49 (90%) for tubing changes. At pretest, scores ranged from a median of 0.0% to 73.1%. At posttest, all scores rose to a median of 100.0%. Total years in nursing and ICU nursing had significant, negative correlations with medication administration pretest performance (r = -0.42, P = .003; r = -0.42, P = .003, respectively). ICU nurses displayed large variability in their ability to perform central line maintenance tasks. After SBML, there was significant improvement, and all nurses reached a predetermined level of competency.
Astaxanthin induces angiogenesis through Wnt/β-catenin signaling pathway.
Xu, Yangyang; Zhang, Jie; Jiang, Wanglin; Zhang, Shuping
2015-07-15
In the present study, we sought to elucidate whether astaxanthin contributes to induce angiogenesis and its mechanisms. To this end, we examined the role of astaxanthin on human brain microvascular endothelial cell line (HBMEC) and rat aortic smooth muscle cell (RASMC) proliferation, invasion and tube formation in vitro. For study of mechanism, the Wnt/β-catenin signaling pathway inhibitor IWR-1-endo was used. HMBECs and RASMCs proliferation were tested by cell counting. Scratch adhesion test was used to assess the ability of invasion. A matrigel tube formation assay was performed to test capillary tube formation ability. The Wnt/β-catenin pathway activation in HMBECs and RASMCs were tested by Western blot. Our data suggested that astaxanthin induces angiogenesis by increasing proliferation, invasion and tube formation in vitro. Wnt and β-catenin expression were increased by astaxanthin and counteracted by IWR-1-endo in HMBECs and RASMCs. Tube formation was increased by astaxanthin and counteracted by IWR-1-endo. It may be suggested that astaxanthin induces angiogenesis in vitro via a programmed Wnt/β-catenin signaling pathway. Copyright © 2015 Elsevier GmbH. All rights reserved.
Powell, J. G.
1991-01-01
A nuclear qualified in-containment electrical connection comprises an insulated, sheathed instrument lead having electrical conductors extending from one end thereof to provide two exposed lead wires, a watertight cable having electrical conducting wires therein and extending from one end of the cable to provide two lead wires therefrom, two butt splice connectors each connecting the ends of respective ones of the lead wires from the instrument lead and cable, a length of heat shrinkable plastic tubing positioned over each butt splice connector and an adjacent portion of a respective lead wire from the cable and heat shrunk into position, a length of heat shrinkable plastic tubing on the end portion of the instrument lead adjacent the lead wires therefrom and heat shrunk thereon and a length of outer heat shrinkable plastic tubing extending over the end portion of the instrument lead and the heat shrinkable tubing thereon and over the butt splice connectors and a portion of the cable adjacent the cable lead lines, the outer heat shrinkable tubing being heat shrunk into sealing position on the instrument lead and cable.
Herrero, Maria
2017-01-01
Background and Aims Within the ovary, the obturator bridges the pathway of the pollen tube from the style to the ovule. Despite its widespread presence among flowering plants, its function has only been studied in a handful of species, and the molecules involved in pollen tube–obturator cross-talk have not been explored hitherto. This work evaluates the involvement of glucans and glycoproteins on pollen tube growth in the obturator of apple flowers (Malus × domestica). Methods Pollen tube kinetics were sequentially examined in the pistil and related to changes occurring on the obturator using histochemistry and inmunocytochemistry. To discriminate between changes in the obturator induced by pollen tubes from those developmentally regulated, both pollinated and unpollinated pistils were examined. Key Results Pollen tube growth rates were slow in the stigma, faster in the style and slow again in the ovary. The arrival of pollen tubes at the obturator was concomitant with the secretion of proteins, saccharides and glycoprotein epitopes belonging to extensins and arabinogalactan proteins (AGPs). While some of these secretions – extensins and AGPs labelled by JIM13 – were developmentally regulated, others – AGPs labelled by JIM8 – were elicited by the presence of pollen tubes. Following pollen tube passage, all these glycoproteins were depleted. Conclusions The results show a timely secretion of glycoproteins on the obturator surface concomitant with pollen tube arrival at this structure. The fact that their secretion is depleted following pollen tube passage strongly suggests their role in regulating pollen tube access to the ovule. Remarkably, both the regulation of the secretion of the different glycoproteins, as well as their association with the performance of pollen tubes exhibit similarities with those observed in the stigma, in line with their common developmental origin. PMID:28137704
Stripe-like Clay Nanotubes Patterns in Glass Capillary Tubes for Capture of Tumor Cells.
Liu, Mingxian; He, Rui; Yang, Jing; Zhao, Wei; Zhou, Changren
2016-03-01
Here, we used capillary tubes to evaporate an aqueous dispersion of halloysite nanotubes (HNTs) in a controlled manner to prepare a patterned surface with ordered alignment of the nanotubes . Sodium polystyrenesulfonate (PSS) was added to improve the surface charges of the tubes. An increased negative charge of HNTs is realized by PSS coating (from -26.1 mV to -52.2 mV). When the HNTs aqueous dispersion concentration is higher than 10%, liquid crystal phenomenon of the dispersion is found. A typical shear flow behavior and decreased viscosity upon shear is found when HNTs dispersions with concentrations higher than 10%. Upon drying the HNTs aqueous dispersion in capillary tubes, a regular pattern is formed in the wall of the tube. The width and spacing of the bands increase with HNTs dispersion concentration and decrease with the drying temperature for a given initial concentration. Morphology results show that an ordered alignment of HNTs is found especially for the sample of 10%. The patterned surface can be used as a model for preparing PDMS molding with regular micro-/nanostructure. Also, the HNTs rough surfaces can provide much higher tumor cell capture efficiency compared to blank glass surfaces. The HNTs ordered surfaces provide promising application for biomedical areas such as biosensors.
Kouno, Takuya; Kuga, Noriyuki; Enzaki, Masahiro; Yamashita, Yuuki; Kitazato, Yumiko; Shimotabira, Haruhiko; Jinnouchi, Takashi; Kusuhara, Kazuo; Kawamura, Shinji
2015-04-01
The aim of this study was to reduce the exposed dose of radiotherapy treatment planning computed tomography (CT) by using low tube voltage technique. We used tube voltages of 80 kV, 100 kV, and 120 kV, respectively. First, we evaluated exposure dose with CT dose index (CTDI) for each voltage. Second, we compared image quality indexes such as modulation transfer function (MTF), noise power spectrum (NPS), and contrast to noise ratio (CNR) of phantom images with each voltage. Third, CT to electron density tables were measured in three voltages and monitor unit value was calculated along with clinical cases. Finally, CT surface exposed dose of chest skin was measured by thermoluminescent dosimeter (TLD). In image evaluation MTF and NPS were approximately equal; CNR slightly decreased, 2.0% for 100 kV. We performed check radiation dose accuracy for each tube voltage with each model phantom. As a result, the difference of MU value was not accepted. Finally, compared with 120 kV, CTDIvol and TLD value showed markedly decreased radiation dose, 60% for 80 kV and 30% for 100 kV. Using a technique with low tube voltages, especially 100 kV, is useful in radiotherapy treatment planning to obtain 20% dose reduction without compromising 120 kV image quality.
Reinforcement for percutaneous nephrostomy tubes with a new technique.
Zhou, Tie; Gao, Xiaofeng; Yang, Cheng; Peng, Yonghan; Xiao, Liang; Xu, Chuanliang; Wang, Linhui; Hou, Jianguo; Sun, Yinghao
2011-01-01
Percutaneous nephrostomy (PCN) still plays a significant role in decompressing the renal collecting system. Percutaneous nephrostomy tubes (PNTs), however, which are flexible and may not be protected well by patients, are vulnerable to mechanical drag, although they are carefully fixed to the skin with silk suture. We developed a simple method to reinforce the nephrostomy tube against dislodgement from the skin. A total of 133 adult patients underwent ultrasonography-guided PCN; 85 patients received a conventional method to fix the tubes, while the other 48 patients received a new one. We used a rubber drainage tube, about 2 cm long, sheared longitudinally, as the outer tube to encase the nephrostomy tube, and then sutured the cutting edges together with the skin suture to reinforce the nephrostomy tube. Compared with the 85 patients who received the conventional method, there was not any tube dislodgement after PCN in the 48 patients who received the new one at the end of 2 weeks (0 vs 7, P=0.049) and 4 weeks (0 vs 10, P=0.014) follow-up. This is a simple, effective, and inexpensive method that can significantly decrease the dislodgement incidence of PNTs and keep them fixed well after surgery.
Ramer, Robert; Fischer, Sascha; Haustein, Maria; Manda, Katrin; Hinz, Burkhard
2014-09-15
Cannabinoids inhibit tumor neovascularization as part of their tumorregressive action. However, the underlying mechanism is still under debate. In the present study the impact of cannabinoids on potential tumor-to-endothelial cell communication conferring anti-angiogenesis was studied. Cellular behavior of human umbilical vein endothelial cells (HUVEC) associated with angiogenesis was evaluated by Boyden chamber, two-dimensional tube formation and fibrin bead assay, with the latter assessing three-dimensional sprout formation. Viability was quantified by the WST-1 test. Conditioned media (CM) from A549 lung cancer cells treated with cannabidiol, Δ(9)-tetrahydrocannabinol, R(+)-methanandamide or the CB2 agonist JWH-133 elicited decreased migration as well as tube and sprout formation of HUVEC as compared to CM of vehicle-treated cancer cells. Inhibition of sprout formation was further confirmed for cannabinoid-treated A549 cells co-cultured with HUVEC. Using antagonists to cannabinoid-activated receptors the antimigratory action was shown to be mediated via cannabinoid receptors or transient receptor potential vanilloid 1. SiRNA approaches revealed a cannabinoid-induced expression of tissue inhibitor of matrix metalloproteinases-1 (TIMP-1) as well as its upstream trigger, the intercellular adhesion molecule-1, to be causally linked to the observed decrease of HUVEC migration. Comparable anti-angiogenic effects were not detected following direct exposure of HUVEC to cannabinoids, but occurred after addition of recombinant TIMP-1 to HUVEC. Finally, antimigratory effects were confirmed for CM of two other cannabinoid-treated lung cancer cell lines (H460 and H358). Collectively, our data suggest a pivotal role of the anti-angiogenic factor TIMP-1 in intercellular tumor-endothelial cell communication resulting in anti-angiogenic features of endothelial cells. Copyright © 2014 Elsevier Inc. All rights reserved.
Herts, Brian R; Baker, Mark E; Obuchowski, Nancy; Primak, Andrew; Schneider, Erika; Rhana, Harpreet; Dong, Frank
2013-06-01
The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.
On the formation of vortex rings in coaxial tubes
NASA Astrophysics Data System (ADS)
Gan, Lian
2011-11-01
The formation of vortex rings within coaxial tubes of different diameter is investigated experimentally and numerically. PIV measurements were carried out in a water tank equipped with a piston-cylinder apparatus used to generate vortex rings inside a series of coaxial tubes with tube to piston diameter ratios, DT / D , ranging from 4 to 1.5. In order to distinguish between the effect confinement has on the formation of isolated vortex rings from those formed with a trailing jet flow, non- dimensional stroke ratios below and above the formation number were investigated, L / D = 2 . 5 and 10 respectively. For DT / D > 2 and L / D s below the formation number the kinematics of the vortex rings follow classical inviscid theory in so much as their self-induced velocity decreases linearly with decreasing tube diameter in accordance with the image theorem. For DT / D <= 2 boundary layer separation along the tube wall begins to interfere with the vortex during its roll-up phase. For vortex rings below the formation number, the vortex core is briefly arrested upon completion of the piston stroke. On the other hand, long L / D s give rise to even more complex dynamics. When DT / D = 2 the interaction between boundary layer and the starting jet acts to suppress vortex ring formation altogether. However, as confinement is increased further to DT / D = 1 . 5 the formation of a lead vortex ring re-appears but with a circulation lower than the formation number before rapidly decaying.
Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li’an; Xia, Liangyu; Qiu, Ling
2015-01-01
Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy. PMID:26420221
Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li'an; Xia, Liangyu; Qiu, Ling
2015-09-30
Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy.
NASA Astrophysics Data System (ADS)
Loan Nguyen, Thu; Dieu Thuy Ung, Thi; Liem Nguyen, Quang
2014-06-01
This paper reports on the fabrication of non-chapped, vertically well aligned titanium dioxide nanotubes (TONTs) by using electrochemical etching method and further heat treatment. Very highly ordered metallic titanium nanotubes (TNTs) were formed by directly anodizing titanium foil at room temperature in an electrolyte composed of ammonium fluoride (NH4F), ethylene glycol (EG), and water. The morphology of as-formed TNTs is greatly dependent on the applied voltage, NH4F content and etching time. Particularly, we have found two interesting points related to the formation of TNTs: (i) the smooth surface without chaps of the largely etched area was dependent on the crystalline orientation of the titanium foil; and (ii) by increasing the anodizing potential from 15 V to 20 V, the internal diameter of TNT was increased from about 50 nm to 60 nm and the tube density decreased from 403 tubes μm-2 down to 339 tubes μm-2, respectively. For the anodizing duration from 1 h to 5 h, the internal diameter of each TNT was increased from ˜30 nm to 60 nm and the tube density decreased from 496 tubes μm-2 down to 403 tubes μm-2. After annealing at 400 °C in open air for 1 h, the TNTs were transformed into TONTs in anatase structure; further annealing at 600 °C showed the structural transformation from anatase to rutile as determined by Raman scattering spectroscopy.
Madureira, Ana Raquel; Campos, Débora A; Oliveira, Ana; Sarmento, Bruno; Pintado, Maria Manuela; Gomes, Ana Maria
2016-03-01
The evaluation of the digestion effects on bioactive solid lipid nanoparticles (SLN) was performed. For this purpose, witepsol and carnauba SLN loaded with rosmarinic acid (RA) were exposed to the simulated gastrointestinal tract (GIT) conditions prevailing in stomach and small intestine. The simulation of intestinal epithelium was made with a dialysis bag and intestinal cell culture lines. Changes on SLN physical properties, RA release and absorption profiles were followed at each step. Combination of digestion pH and enzymes showed a significant effect upon SLN physical properties. Zeta potential values increased at stomach conditions and decreased at small intestine simulation. Also, at intestine, SLN increased their sizes and released 40-60% of RA, maintaining its initial antioxidant activity values. Sustained release of 40% of RA from SLN was also observed in dialysis tube. At CaCo-2 cell line, both types of SLN showed similar absorbed RA % (ca. 30%). Nevertheless, in CaCo-2/HT29x mix cell lines, for carnauba SLN a lower adsorption RA % was observed than for witepsol SLN. Solid lipid nanoparticles protected RA bioactivity (in terms of antioxidant activity) until reaching the intestine. A controlled release of RA from SLN was achieved and a significant absorption was observed at intestinal cells. Overall, SLN produced with witepsol showed a higher stability than carnauba SLN. Copyright © 2015 Elsevier B.V. All rights reserved.
Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu
2018-01-01
Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.
A 3-D analysis of the protympanum in human temporal bones with chronic ear disease.
Pauna, Henrique F; Monsanto, Rafael C; Schachern, Patricia; Paparella, Michael M; Cureoglu, Sebahattin
2017-03-01
Eustachian tube dysfunction is believed to be an important factor to cholesteatoma development and recurrence of disease after surgical treatment. Although many studies have described prognostic factors, evaluation methods, or surgical techniques for Eustachian tube dysfunction, they relied on the soft tissues of its structure; little is known about its bony structure-the protympanum-which connects the Eustachian tube to the tympanic cavity, and can also be affected by several inflammatory conditions, both from the middle ear or from the nasopharynx. We studied temporal bones from patients with cholesteatoma, chronic otitis media (with and without retraction pockets), purulent otitis media, and non-diseased ears, looking for differences between the volume of the protympanum, the diameter of the Eustachian tube isthmus, and the distance between the anterior tympanic annulus and the promontory. Light microscopy and 3-D reconstruction software were used for the measurements. We observed a decrease of volume in the lumen of the four middle ear diseased ears compared to the control group. We observed a significant decrease in the volume of the protympanic space in the cholesteatoma group compared to the chronic otitis media group. We also observed a decrease in the bony space (protympanum space) in cholesteatoma, chronic otitis media with retraction pockets, and purulent otitis media compared to the control group. We found a correlation in middle ear diseases and a decrease in the middle ear space. Our findings may suggest that a smaller bony volume in the protympanic area may trigger middle ear dysventilation problems.
Anand, Rahul J; Whelan, James F; Ferrada, Paula; Duane, Therese M; Malhotra, Ajai K; Aboutanos, Michel B; Ivatury, Rao R
2012-04-01
The factors contributing to the development of pneumothorax after removal of chest tube thoracostomy are not fully understood. We hypothesized that development of post pull pneumothorax (PPP) after chest tube removal would be significantly lower in those patients with thicker chest walls, due to the "protective" layer of adipose tissue. All patients on our trauma service who underwent chest tube thoracostomy from July 2010 to February 2011 were retrospectively reviewed. Patient age, mechanism of trauma, and chest Abbreviated Injury Scale score were analyzed. Thoracic CTs were reviewed to ascertain chest wall thickness (CW). Thickness was measured at the level of the nipple at the midaxillary line, as perpendicular distance between skin and pleural cavity. Chest X-ray reports from immediately prior and after chest tube removal were reviewed for interval development of PPP. Data are presented as average ± standard deviation. Ninety-one chest tubes were inserted into 81 patients. Patients who died before chest tube removal (n = 11), or those without thoracic CT scans (n = 13) were excluded. PPP occurred in 29.9 per cent of chest tube removals (20/67). When PPP was encountered, repeat chest tube was necessary in 20 per cent of cases (4/20). After univariate analysis, younger age, penetrating mechanism, and thin chest wall were found to be significant risk factors for development of PPP. Chest Abbreviated Injury Scale score was similar in both groups. Logistic regression showed only chest wall thickness to be an independent risk factor for development of PPP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-Sykora, Juan; Cheung, Mark C. M.; Moreno-Insertis, Fernando
We study the buoyant rise of magnetic flux tubes embedded in an adiabatic stratification using two-and three-dimensional, magnetohydrodynamic simulations. We analyze the dependence of the tube evolution on the field line twist and on the curvature of the tube axis in different diffusion regimes. To be able to achieve a comparatively high spatial resolution we use the FLASH code, which has a built-in Adaptive Mesh Refinement (AMR) capability. Our 3D experiments reach Reynolds numbers that permit a reasonable comparison of the results with those of previous 2D simulations. When the experiments are run without AMR, hence with a comparatively largemore » diffusivity, the amount of longitudinal magnetic flux retained inside the tube increases with the curvature of the tube axis. However, when a low-diffusion regime is reached by using the AMR algorithms, the magnetic twist is able to prevent the splitting of the magnetic loop into vortex tubes and the loop curvature does not play any significant role. We detect the generation of vorticity in the main body of the tube of opposite sign on the opposite sides of the apex. This is a consequence of the inhomogeneity of the azimuthal component of the field on the flux surfaces. The lift force associated with this global vorticity makes the flanks of the tube move away from their initial vertical plane in an antisymmetric fashion. The trajectories have an oscillatory motion superimposed, due to the shedding of vortex rolls to the wake, which creates a Von Karman street.« less
Knoblauch, Michael; Froelich, Daniel R; Pickard, William F; Peters, Winfried S
2014-04-01
The phloem provides a network of sieve tubes for long-distance translocation of photosynthates. For over a century, structural proteins in sieve tubes have presented a conundrum since they presumably increase the hydraulic resistance of the tubes while no potential function other than sieve tube or wound sealing in the case of injury has been suggested. Here we summarize and critically evaluate current speculations regarding the roles of these proteins. Our understanding suffers from the suggestive power of images; what looks like a sieve tube plug on micrographs may not actually impede translocation very much. Recent reports of an involvement of SEOR (sieve element occlusion-related) proteins, a class of P-proteins, in the sealing of injured sieve tubes are inconclusive; various lines of evidence suggest that, in neither intact nor injured plants, are SEORs determinative of translocation stoppage. Similarly, the popular notion that P-proteins serve in the defence against phloem sap-feeding insects is unsupported by empirical facts; it is conceivable that in functional sieve tubes, aphids actually could benefit from inducing a plug. The idea that rising cytosolic Ca(2+) generally triggers sieve tube blockage by P-proteins appears widely accepted, despite lacking experimental support. Even in forisomes, P-protein assemblages restricted to one single plant family and the only Ca(2+)-responsive P-proteins known, the available evidence does not unequivocally suggest that plug formation is the cause rather than a consequence of translocation stoppage. We conclude that the physiological roles of structural P-proteins remain elusive, and that in vivo studies of their dynamics in continuous sieve tube networks combined with flow velocity measurements will be required to (hopefully) resolve this scientific roadblock.
Mangold, Stefanie; Wichmann, Julian L; Schoepf, U Joseph; Poole, Zachary B; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Bamberg, Fabian; Nikolaou, Konstantin; De Cecco, Carlo N
2016-10-01
To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3(rd) generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥ .0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p < .0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥ .0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤ .0414). Correlation analysis showed a moderate association between tube voltage and BMI (r = .639). ATVS allows individual tube voltage adaptation for CCTA performed with 3(rd) generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. • Automated tube voltage selection allows an individual tube voltage adaption in CCTA. • A tube voltage-based reduction of contrast medium volume is feasible. • Image quality was maintained while radiation exposure was significantly decreased. • A moderate association between tube voltage and body mass index was found.
NASA Astrophysics Data System (ADS)
Nazifah, A.; Norhanna, S.; Shah, S. I.; Zakaria, A.
2014-11-01
This study aimed to investigate the effects of material filter technique on Tc-99m spectra and performance parameters of Philip ADAC forte dual head gamma camera. Thickness of material filter was selected on the basis of percentage attenuation of various gamma ray energies by different thicknesses of zinc material. A cylindrical source tank of NEMA single photon emission computed tomography (SPECT) Triple Line Source Phantom filled with water and Tc-99m radionuclide injected was used for spectra, uniformity and sensitivity measurements. Vinyl plastic tube was used as a line source for spatial resolution. Images for uniformity were reconstructed by filtered back projection method. Butterworth filter of order 5 and cut off frequency 0.35 cycles/cm was selected. Chang's attenuation correction method was applied by selecting 0.13/cm linear attenuation coefficient. Count rate was decreased with material filter from the compton region of Tc-99m energy spectrum, also from the photopeak region. Spatial resolution was improved. However, uniformity of tomographic image was equivocal, and system volume sensitivity was reduced by material filter. Material filter improved system's spatial resolution. Therefore, the technique may be used for phantom studies to improve the image quality.
Factors Influencing the Duration of Urine Leakage following Percutaneous Nephrolithotomy.
Uyeturk, Ugur; Gucuk, Adnan; Kemahli, Eray; Dagistan, Emine; Yildiz, Mevlut; Yilmaz, Burak; Metin, Ahmet
2014-01-01
Purpose. The duration of urine leakage following the removal of the nephrostomy tube after percutaneous nephrolithotomy (PCNL) shows significant variations depending on the techniques used. We aimed to assess the factors likely to influence the duration of urine leakage. Material and Methods. In total, 103 patients who underwent PCNL were reviewed retrospectively. DUL was evaluated regarding patient characteristics, thickness of the access line, presence of hydronephrosis, and residual stones. Results. DUL was significantly prolonged in accordance with a decrease in the thickness of parenchyma tissue (R = -0.716, P < 0.001). DUL was prolonged as the degree of hydronephrosis (R = 0.526, P < 0.001) and the number of patients with residual stones (R = 0.273, P = 0.005) increased. Median DUL was significantly longer in patients with residual stones than those without residual stones (P = 0.002). In the receiving operating curve analysis, the optimum cut-off value of parenchymal thickness for hospitalization ≤12 h was 17.2 mm (sensitivity, 90.2%; specificity, 69.4%; P = 0.001). Conclusions. We found that parenchymal thickness of the access line, hydronephrosis, and residual stones were the most influential factors determining DUL following PCNL, respectively.
Effect of Magnetic Twist on Nonlinear Transverse Kink Oscillations of Line-tied Magnetic Flux Tubes
NASA Astrophysics Data System (ADS)
Terradas, J.; Magyar, N.; Van Doorsselaere, T.
2018-01-01
Magnetic twist is thought to play an important role in many structures of the solar atmosphere. One of the effects of twist is to modify the properties of the eigenmodes of magnetic tubes. In the linear regime standing kink solutions are characterized by a change in polarization of the transverse displacement along the twisted tube. In the nonlinear regime, magnetic twist affects the development of shear instabilities that appear at the tube boundary when it is oscillating laterally. These Kelvin–Helmholtz instabilities (KHI) are produced either by the jump in the azimuthal component of the velocity at the edge of the sharp boundary between the internal and external part of the tube or by the continuous small length scales produced by phase mixing when there is a smooth inhomogeneous layer. In this work the effect of twist is consistently investigated by solving the time-dependent problem including the process of energy transfer to the inhomogeneous layer. It is found that twist always delays the appearance of the shear instability, but for tubes with thin inhomogeneous layers the effect is relatively small for moderate values of twist. On the contrary, for tubes with thick layers, the effect of twist is much stronger. This can have some important implications regarding observations of transverse kink modes and the KHI itself.
Noise analysis in numerical modeling of crossed fields microwave tubes
NASA Astrophysics Data System (ADS)
BłaŻejewicz, Mariusz; Woźniak, Martyna; Szkop, Emil; RóŻycki, Andrzej; Rychlewski, Michał; Baczewski, Dariusz; Laskowski, Dariusz
2018-04-01
One of the most important parameters that characterize microwave tubes with crossed fields, both amplifiers (CFA), and generating tubes like magnetrons is the noise level. This type of tubes are characterized by relatively high noise levels, which is the main factor limiting their current use in radar transmitters. The main source of noise in microwave tubes of this type is the dispersion of the energy of electrons that are in phase with the spatial wave of the electromagnetic field propagating in the delay line (in case of an amplitron) or in the resonant structure (in case of a magnetron).The results of the research presented in the article concern the technique of determination of Signal to Noise Ratio (SNR) based on the analysis of results obtained during the numerical simulations of the effect of electric charge on a high frequency electromagnetic field. Signal to noise ratio was determined by analysing in-phase and quadrature data recorded in the high frequency simulation. In order to assess the accuracy of the method under investigation, the results from the noise analysis obtained from numerical calculations were compared with the results obtained from real tube measurements performed by a spectrum analyser. On the basis of the research, it appears that performing analysis of noise generated in the interaction area may be useful for preliminary evaluation of the tube at the design stage.
A shock-tube determination of the SiO /A 1 Pi - X 1 Sigma +/ transition moment
NASA Technical Reports Server (NTRS)
Park, C.; Arnold, J. O.
1978-01-01
The sum of the squares of the electronic transition moments for the A 1 Pi - X 1 Sigma + band system of SiO has been determined from absorption measurements conducted in the reflected-shock region of a shock tube. The test gas was produced by shock-heating a mixture of N2O, SiCl4, and Ar, and the spectra were recorded photographically in the 260-290-nm wavelength range. The values of the sum as a function of internuclear distance between 2.8 and 3.3 Bohr were determined by comparing the measured absorption spectrum with that produced by a line-by-line synthetic-spectrum calculation which accounted for instrumental broadening. The value of the sum so deduced at an internuclear distance of 3.0 Bohr was 1.0 + or - 0.3 atomic units.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dean, R.S.; Foley, W.J.; Hennick, A.
1989-05-01
Documentation is provided in this report for the closeout of IE Bulletin 83-06 regarding nonconformities of certain materials which were obtained directly or indirectly from the Tube-Line Corporation (T-L) for use in safety-related systems. Closeout is based on the implementation and verification of four (4) required actions by licensees and holders of construction permits of nuclear power reactor and nuclear fuel facilities. From evaluation of responses and NRC/Region inspection reports, it is concluded that the concerns of the bulletin have been resolved. The bulletin is closed for all of the 120 power reactor facilities and for both of the twomore » nuclear fuel facilities to which it was issued for action. Background information is supplied in the Introduction and Appendix A. 3 refs., 5 tabs.« less
Origin and Correction of Magnetic Field Inhomogeneity at the Interface in Biphasic NMR Samples
Martin, Bryan T.; Chingas, G. C.
2012-01-01
The use of susceptibility matching to minimize spectral distortion of biphasic samples layered in a standard 5 mm NMR tube is described. The approach uses magic angle spinning (MAS) to first extract chemical shift differences by suppressing bulk magnetization. Then, using biphasic coaxial samples, magnetic susceptibilities are matched by titration with a paramagnetic salt. The matched phases are then layered in a standard NMR tube where they can be shimmed and examined. Line widths of two distinct spectral lines, selected to characterize homogeneity in each phase, are simultaneously optimized. Two-dimensional distortion-free, slice-resolved spectra of an octanol/water system illustrate the method. These data are obtained using a 2D stepped-gradient pulse sequence devised for this application. Advantages of this sequence over slice-selective methods are that acquisition efficiency is increased and processing requires only conventional software. PMID:22459062
Electronic structure and optical properties of boron nitride nanotube bundles from first principles
NASA Astrophysics Data System (ADS)
Behzad, Somayeh
2015-06-01
The electronic and optical properties of bundled armchair and zigzag boron nitride nanotubes (BNNTs) are investigated by using density functional theory. Owing to the inter-tube coupling, the dispersions along the tube axis and in the plane perpendicular to the tube axis of BNNT bundles are significantly varied, which are characterized by the decrease of band gap, the splitting of the doubly degenerated states, the expansions of valence and conduction bands. The calculated dielectric functions of the armchair and zigzag bundles are similar to that of the isolated tubes, except for the appearance of broadened peaks, small shifts of peak positions about 0.1 eV and increasing of peak intensities.
Design, development and testing twin pulse tube cryocooler
NASA Astrophysics Data System (ADS)
Gour, Abhay Singh; Sagar, Pankaj; Karunanithi, R.
2017-09-01
The design and development of Twin Pulse Tube Cryocooler (TPTC) is presented. Both the coolers are driven by a single Linear Moving Magnet Synchronous Motor (LMMSM) with piston heads at both ends of the mover shaft. Magnetostatic analysis for flux line distribution was carried-out during design and development of LMMSM based pressure wave generator. Based on the performance of PWG, design of TPTC was carried out using Sage and Computational Fluid Dynamics (CFD) analysis. Detailed design, fabrication and testing of LMMSM, TPTC and their integration tests are presented in this paper.
Not Available
1980-03-07
A heat transfer system for a nuclear reactor is described. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.
McGuire, Joseph C.
1982-01-01
A heat transfer system for a nuclear reactor. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.
2010-02-01
the flue gas was measured with an S-type Pitot tube connected to an inclined oil manometer, and the temperature of the flue gas was measured with a...umbilical line, a vacuum pump, a dry gas meter, and a calibrated orifice connected to an inclined oil manometer. The moisture content was less than 2% so...flue gas was measured with an S-type Pitot tube connected to an inclined oil manometer, and the temperature of the flue gas was measured with a chromel
Management of traumatic hemothorax by closed thoracic drainage using a central venous catheter
Yi, Jian-hua; Liu, Hua-bo; Zhang, Mao; Wu, Jun-song; Yang, Jian-xin; Chen, Jin-ming; Xu, Shan-xiang; Wang, Jian-an
2012-01-01
Objective: To evaluate the efficacy and safety of the treatment of traumatic hemothorax by closed pleural drainage using a central venous catheter (CVC), compared with using a conventional chest tube. Methods: A prospective controlled study with the Ethics Committee approval was undertaken. A total of 407 patients with traumatic hemothorax were involved and they were randomly assigned to undergo closed pleural drainage with CVCs (n=214) or conventional chest tubes (n=193). The Seldinger technique was used for drainage by CVC, and the conventional technique for drainage by chest tube. If the residual volume of the hemothorax was less than 200 ml after the daily volume of drainage decreased to below 100 ml for two consecutive days, the treatment was considered successful. The correlative data of efficacy and safety between the two groups were analyzed using t or chi-squared tests with SPSS 13.0. A P value of less than 0.05 was taken as indicating statistical significance. Results: Compared with the chest tube group, the operation time, fraction of analgesic treatment, time of surgical wound healing, and infection rate of surgical wounds were significantly decreased (P<0.05) in the CVC group. There were no significant differences between the two groups in the success rate of treatment and the incidence of serious complications (P>0.05), or in the mean catheter/tube indwelling time and mean medical costs of patients treated successfully (P>0.05). Conclusions: Management of medium or large traumatic hemothoraxes by closed thoracic drainage using CVC is minimally invasive and as effective as using a conventional large-bore chest tube. Its complications can be prevented and it has the potential to replace the large-bore chest tube. PMID:22205619
Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.
Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric
2015-01-01
To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.
Electrical transmission line diametrical retainer
Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe
2004-12-14
The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.
Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.
2011-01-01
Purpose: To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. Materials and Methods: The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0–16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDIvol) or dose–length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Results: Organ dose normalized by tube current–time product or CTDIvol decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current–time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current–time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (<10% variation). Conclusion: The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1 PMID:21467251
Patient-specific radiation dose and cancer risk for pediatric chest CT.
Li, Xiang; Samei, Ehsan; Segars, W Paul; Sturgeon, Gregory M; Colsher, James G; Frush, Donald P
2011-06-01
To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Organ dose normalized by tube current-time product or CTDI(vol) decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (<10% variation). The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1. RSNA, 2011
Bajaj, Pramila; Nanda, Rajan; Goyal, Pradeep KR
2004-10-01
The study was designed to investigate the changes in pressure and volume of a tracheal tube-cuff inflated with air, mixture of N2O + O2, saline and 4% lidocaine during nitrous oxide anesthesia. This study was conducted in 80 patients (33 male & 47 female). The pressure and volume of a tracheal tube cuff increased with air, decreased with mixture of N2O + O2 and almost remained the same with saline and 4% lidocaine. The complications were more in the air group.
Acoustic Resonance and Vortex Shedding from Tube Banks of Boiler Plant
NASA Astrophysics Data System (ADS)
Hamakawa, Hiromitsu; Matsue, Hiroto; Nishida, Eiichi; Fukano, Tohru
This paper focuses on the relationship between acoustic resonance and vortex shedding from the tube banks of a boiler plant. We have built a model similar to the actual boiler plant to clarify the characteristics of acoustic resonance phenomena and vortex shedding. The model used in-line tube banks with a small tube pitch ratio. We examined the relationship between the acoustic resonance of the actual plant and that of the model, and measured the sound pressure level, acoustic pressure mode shape, spectrum of velocity fluctuation, and gap velocity. Gap velocity was defined as the mean velocity in the smallest gaps between two neighboring tubes in the transverse direction. As a result, the resonant frequencies and mode shapes of the acoustic resonances in the actual boiler plant agreed well with those in the similar model. We found many peak frequencies in the sound pressure level spectrum when acoustic resonances occurred. The typical Strouhal numbers at the onset velocity of acoustic resonances were about 0.19, 0.26 and 0.52. Periodic velocity fluctuation caused by vortex shedding was observed inside the tube banks without acoustic resonance. The Strouhal number measured for vortex shedding was 0.15. Acoustic resonances of higher-order modes were generated in this plant.
Pediatric Tubular Pulmonary Heart Valve from Decellularized Engineered Tissue Tubes
Reimer, Jay M.; Syedain, Zeeshan H.; Haynie, Bee H.T.; Tranquillo, Robert T.
2015-01-01
Pediatric patients account for a small portion of the heart valve replacements performed, but a pediatric pulmonary valve replacement with growth potential remains an unmet clinical need. Herein we report the first tubular heart valve made from two decellularized, engineered tissue tubes attached with absorbable sutures, which can meet this need, in principle. Engineered tissue tubes were fabricated by allowing ovine dermal fibroblasts to replace a sacrificial fibrin gel with an aligned, cell-produced collagenous matrix, which was subsequently decellularized. Previously, these engineered tubes became extensively recellularized following implantation into the sheep femoral artery. Thus, a tubular valve made from these tubes may be amenable to recellularization and, ideally, somatic growth. The suture line pattern generated three equi-spaced “leaflets” in the inner tube, which collapsed inward when exposed to back pressure, per tubular valve design. Valve testing was performed in a pulse duplicator system equipped with a secondary flow loop to allow for root distention. All tissue-engineered valves exhibited full leaflet opening and closing, minimal regurgitation (< 5%), and low systolic pressure gradients (< 2.5 mmHg) under pulmonary conditions. Valve performance was maintained under various trans-root pressure gradients and no tissue damage was evident after 2 million cycles of fatigue testing. PMID:26036175
Davis, George E.; Stratman, Amber N.; Sacharidou, Anastasia; Koh, Wonshill
2013-01-01
Many studies reveal a fundamental role for extracellular matrix-mediated signaling through integrins and Rho GTPases as well as matrix metalloproteinases (MMPs) in the molecular control of vascular tube morphogenesis in three-dimensional (3D) tissue environments. Recent work has defined an EC lumen signaling complex of proteins that controls these vascular morphogenic events. These findings reveal a signaling interdependence between Cdc42 and MT1-MMP to control the 3D matrix-specific process of EC tubulogenesis. The EC tube formation process results in the creation of a network of proteolytically-generated vascular guidance tunnels in 3D matrices that are utilized to remodel EC-lined tubes through EC motility and could facilitate processes such as flow-induced remodeling and arteriovenous EC sorting and differentiation. Within vascular guidance tunnels, key dynamic interactions occur between endothelial cells (ECs) and pericytes to affect vessel remodeling, diameter, and vascular basement membrane matrix assembly, a fundamental process necessary for endothelial tube maturation and stabilization. Thus, the EC lumen and tube formation mechanism coordinates the concomitant establishment of a network of vascular tubes within tunnel spaces to allow for flow responsiveness, EC-mural cell interactions, and vascular extracellular matrix assembly to control the development of the functional microcirculation. PMID:21482411
Heating and cooling of the earth's plasma sheet
NASA Technical Reports Server (NTRS)
Goertz, C. K.
1990-01-01
Magnetic-field models based on pressure equilibrium in the quiet magnetotail require nonadiabatic cooling of the plasma as it convects inward or a decrease of the flux tube content. Recent in situ observations of plasma density and temperature indicate that, during quiet convection, the flux tube content may actually increase. Thus the plasma must be cooled during quiet times. The earth plasma sheet is generally significantly hotter after the expansion phase of a substorm than before the plasma sheet thinning begins and cools during the recovery phase. Heating mechanisms such as reconnection, current sheet acceleration, plasma expansion, and resonant absorption of surface waves are discussed. It seems that all mechanisms are active, albeit in different regions of the plasma sheet. Near-earth tail signatures of substorms require local heating as well as a decrease of the flux tube content. It is shown that the resonant absorption of surface waves can provide both.
USDA-ARS?s Scientific Manuscript database
Potatoes are a cool season crop and optimum tuber initiation, development, yield, and quality require growing temperatures between 15 -20°C. At temperatures above 30°C, tuber initiation is delayed or prevented and developing tubers exhibit decreased starch content, increased malformation, chain-tube...
Choice reaction time to visual motion during prolonged rotary motion in airline pilots
NASA Technical Reports Server (NTRS)
Stewart, J. D.; Clark, B.
1975-01-01
Thirteen airline pilots were studied to determine the effect of preceding rotary accelerations on the choice reaction time to the horizontal acceleration of a vertical line on a cathode-ray tube. On each trial, one of three levels of rotary and visual acceleration was presented with the rotary stimulus preceding the visual by one of seven periods. The two accelerations were always equal and were presented in the same or opposite directions. The reaction time was found to increase with increases in the time the rotary acceleration preceded the visual acceleration, and to decrease with increased levels of visual and rotary acceleration. The reaction time was found to be shorter when the accelerations were in the same direction than when they were in opposite directions. These results suggest that these findings are a special case of a general effect that the authors have termed 'gyrovisual modulation'.
Fujiwara, Makoto T; Hashimoto, Haruki; Kazama, Yusuke; Hirano, Tomonari; Yoshioka, Yasushi; Aoki, Seishiro; Sato, Naoki; Itoh, Ryuuichi D; Abe, Tomoko
2010-06-01
The behaviour and multiplication of pollen plastids have remained elusive despite their crucial involvement in cytoplasmic inheritance. Here, we present live images of plastids in pollen grains and growing tubes from transgenic Arabidopsis thaliana lines expressing stroma-localised FtsZ1-green-fluorescent protein fusion in a vegetative cell-specific manner. Vegetative cells in mature pollen contained a morphologically heterogeneous population of round to ellipsoidal plastids, whilst those in late-developing (maturing) pollen included plastids that could have one or two constriction sites. Furthermore, plastids in pollen tubes exhibited remarkable tubulation, stromule (stroma-filled tubule) extension, and back-and-forth movement along the direction of tube growth. Plastid division, which involves the FtsZ1 ring, was rarely observed in mature pollen grains.