A support vector machine approach for classification of welding defects from ultrasonic signals
NASA Astrophysics Data System (ADS)
Chen, Yuan; Ma, Hong-Wei; Zhang, Guang-Ming
2014-07-01
Defect classification is an important issue in ultrasonic non-destructive evaluation. A layered multi-class support vector machine (LMSVM) classification system, which combines multiple SVM classifiers through a layered architecture, is proposed in this paper. The proposed LMSVM classification system is applied to the classification of welding defects from ultrasonic test signals. The measured ultrasonic defect echo signals are first decomposed into wavelet coefficients by the wavelet packet transform. The energy of the wavelet coefficients at different frequency channels are used to construct the feature vectors. The bees algorithm (BA) is then used for feature selection and SVM parameter optimisation for the LMSVM classification system. The BA-based feature selection optimises the energy feature vectors. The optimised feature vectors are input to the LMSVM classification system for training and testing. Experimental results of classifying welding defects demonstrate that the proposed technique is highly robust, precise and reliable for ultrasonic defect classification.
Bidra, Avinash S; Jacob, Rhonda F; Taylor, Thomas D
2012-04-01
Maxillectomy defects are complex and involve a number of anatomic structures. Several maxillectomy defect classifications have been proposed with no universal acceptance among surgeons and prosthodontists. Established criteria for describing the maxillectomy defect are lacking. This systematic review aimed to evaluate classification systems in the available literature, to provide a critical appraisal, and to identify the criteria necessary for a universal description of maxillectomy and midfacial defects. An electronic search of the English language literature between the periods of 1974 and June 2011 was performed by using PubMed, Scopus, and Cochrane databases with predetermined inclusion criteria. Key terms included in the search were maxillectomy classification, maxillary resection classification, maxillary removal classification, maxillary reconstruction classification, midfacial defect classification, and midfacial reconstruction classification. This was supplemented by a manual search of selected journals. After application of predetermined exclusion criteria, the final list of articles was reviewed in-depth to provide a critical appraisal and identify criteria for a universal description of a maxillectomy defect. The electronic database search yielded 261 titles. Systematic application of inclusion and exclusion criteria resulted in identification of 14 maxillectomy and midfacial defect classification systems. From these articles, 6 different criteria were identified as necessary for a universal description of a maxillectomy defect. Multiple deficiencies were noted in each classification system. Though most articles described the superior-inferior extent of the defect, only a small number of articles described the anterior-posterior and medial-lateral extent of the defect. Few articles listed dental status and soft palate involvement when describing maxillectomy defects. No classification system has accurately described the maxillectomy defect, based on criteria that satisfy both surgical and prosthodontic needs. The 6 criteria identified in this systematic review for a universal description of a maxillectomy defect are: 1) dental status; 2) oroantral/nasal communication status; 3) soft palate and other contiguous structure involvement; 4) superior-inferior extent; 5) anterior-posterior extent; and 6) medial-lateral extent of the defect. A criteria-based description appears more objective and amenable for universal use than a classification-based description. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Jiang, Hongquan; Liang, Zeming; Gao, Jianmin; Dang, Changying
2016-03-01
Improving the efficiency and accuracy of weld defect classification is an important technical problem in developing the radiographic testing system. This paper proposes a novel weld defect classification method based on information fusion technology, Dempster-Shafer evidence theory. First, to characterize weld defects and improve the accuracy of their classification, 11 weld defect features were defined based on the sub-pixel level edges of radiographic images, four of which are presented for the first time in this paper. Second, we applied information fusion technology to combine different features for weld defect classification, including a mass function defined based on the weld defect feature information and the quartile-method-based calculation of standard weld defect class which is to solve a sample problem involving a limited number of training samples. A steam turbine weld defect classification case study is also presented herein to illustrate our technique. The results show that the proposed method can increase the correct classification rate with limited training samples and address the uncertainties associated with weld defect classification.
Classification of weld defect based on information fusion technology for radiographic testing system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Hongquan; Liang, Zeming, E-mail: heavenlzm@126.com; Gao, Jianmin
Improving the efficiency and accuracy of weld defect classification is an important technical problem in developing the radiographic testing system. This paper proposes a novel weld defect classification method based on information fusion technology, Dempster–Shafer evidence theory. First, to characterize weld defects and improve the accuracy of their classification, 11 weld defect features were defined based on the sub-pixel level edges of radiographic images, four of which are presented for the first time in this paper. Second, we applied information fusion technology to combine different features for weld defect classification, including a mass function defined based on the weld defectmore » feature information and the quartile-method-based calculation of standard weld defect class which is to solve a sample problem involving a limited number of training samples. A steam turbine weld defect classification case study is also presented herein to illustrate our technique. The results show that the proposed method can increase the correct classification rate with limited training samples and address the uncertainties associated with weld defect classification.« less
Maxillectomy defects: a suggested classification scheme.
Akinmoladun, V I; Dosumu, O O; Olusanya, A A; Ikusika, O F
2013-06-01
The term "maxillectomy" has been used to describe a variety of surgical procedures for a spectrum of diseases involving a diverse anatomical site. Hence, classifications of maxillectomy defects have often made communication difficult. This article highlights this problem, emphasises the need for a uniform system of classification and suggests a classification system which is simple and comprehensive. Articles related to this subject, especially those with specified classifications of maxillary surgical defects were sourced from the internet through Google, Scopus and PubMed using the search terms maxillectomy defects classification. A manual search through available literature was also done. The review of the materials revealed many classifications and modifications of classifications from the descriptive, reconstructive and prosthodontic perspectives. No globally acceptable classification exists among practitioners involved in the management of diseases in the mid-facial region. There were over 14 classifications of maxillary defects found in the English literature. Attempts made to address the inadequacies of previous classifications have tended to result in cumbersome and relatively complex classifications. A single classification that is based on both surgical and prosthetic considerations is most desirable and is hereby proposed.
Context-based automated defect classification system using multiple morphological masks
Gleason, Shaun S.; Hunt, Martin A.; Sari-Sarraf, Hamed
2002-01-01
Automatic detection of defects during the fabrication of semiconductor wafers is largely automated, but the classification of those defects is still performed manually by technicians. This invention includes novel digital image analysis techniques that generate unique feature vector descriptions of semiconductor defects as well as classifiers that use these descriptions to automatically categorize the defects into one of a set of pre-defined classes. Feature extraction techniques based on multiple-focus images, multiple-defect mask images, and segmented semiconductor wafer images are used to create unique feature-based descriptions of the semiconductor defects. These feature-based defect descriptions are subsequently classified by a defect classifier into categories that depend on defect characteristics and defect contextual information, that is, the semiconductor process layer(s) with which the defect comes in contact. At the heart of the system is a knowledge database that stores and distributes historical semiconductor wafer and defect data to guide the feature extraction and classification processes. In summary, this invention takes as its input a set of images containing semiconductor defect information, and generates as its output a classification for the defect that describes not only the defect itself, but also the location of that defect with respect to the semiconductor process layers.
NASA Astrophysics Data System (ADS)
Zhu, Jun; Chen, Lijun; Ma, Lantao; Li, Dejian; Jiang, Wei; Pan, Lihong; Shen, Huiting; Jia, Hongmin; Hsiang, Chingyun; Cheng, Guojie; Ling, Li; Chen, Shijie; Wang, Jun; Liao, Wenkui; Zhang, Gary
2014-04-01
Defect review is a time consuming job. Human error makes result inconsistent. The defects located on don't care area would not hurt the yield and no need to review them such as defects on dark area. However, critical area defects can impact yield dramatically and need more attention to review them such as defects on clear area. With decrease in integrated circuit dimensions, mask defects are always thousands detected during inspection even more. Traditional manual or simple classification approaches are unable to meet efficient and accuracy requirement. This paper focuses on automatic defect management and classification solution using image output of Lasertec inspection equipment and Anchor pattern centric image process technology. The number of mask defect found during an inspection is always in the range of thousands or even more. This system can handle large number defects with quick and accurate defect classification result. Our experiment includes Die to Die and Single Die modes. The classification accuracy can reach 87.4% and 93.3%. No critical or printable defects are missing in our test cases. The missing classification defects are 0.25% and 0.24% in Die to Die mode and Single Die mode. This kind of missing rate is encouraging and acceptable to apply on production line. The result can be output and reloaded back to inspection machine to have further review. This step helps users to validate some unsure defects with clear and magnification images when captured images can't provide enough information to make judgment. This system effectively reduces expensive inline defect review time. As a fully inline automated defect management solution, the system could be compatible with current inspection approach and integrated with optical simulation even scoring function and guide wafer level defect inspection.
NASA Astrophysics Data System (ADS)
Kuo, Chung-Feng Jeffrey; Lai, Chun-Yu; Kao, Chih-Hsiang; Chiu, Chin-Hsun
2018-05-01
In order to improve the current manual inspection and classification process for polarizing film on production lines, this study proposes a high precision automated inspection and classification system for polarizing film, which is used for recognition and classification of four common defects: dent, foreign material, bright spot, and scratch. First, the median filter is used to remove the impulse noise in the defect image of polarizing film. The random noise in the background is smoothed by the improved anisotropic diffusion, while the edge detail of the defect region is sharpened. Next, the defect image is transformed by Fourier transform to the frequency domain, combined with a Butterworth high pass filter to sharpen the edge detail of the defect region, and brought back by inverse Fourier transform to the spatial domain to complete the image enhancement process. For image segmentation, the edge of the defect region is found by Canny edge detector, and then the complete defect region is obtained by two-stage morphology processing. For defect classification, the feature values, including maximum gray level, eccentricity, the contrast, and homogeneity of gray level co-occurrence matrix (GLCM) extracted from the images, are used as the input of the radial basis function neural network (RBFNN) and back-propagation neural network (BPNN) classifier, 96 defect images are then used as training samples, and 84 defect images are used as testing samples to validate the classification effect. The result shows that the classification accuracy by using RBFNN is 98.9%. Thus, our proposed system can be used by manufacturing companies for a higher yield rate and lower cost. The processing time of one single image is 2.57 seconds, thus meeting the practical application requirement of an industrial production line.
Improvement in defect classification efficiency by grouping disposition for reticle inspection
NASA Astrophysics Data System (ADS)
Lai, Rick; Hsu, Luke T. H.; Chang, Peter; Ho, C. H.; Tsai, Frankie; Long, Garrett; Yu, Paul; Miller, John; Hsu, Vincent; Chen, Ellison
2005-11-01
As the lithography design rule of IC manufacturing continues to migrate toward more advanced technology nodes, the mask error enhancement factor (MEEF) increases and necessitates the use of aggressive OPC features. These aggressive OPC features pose challenges to reticle inspection due to high false detection, which is time-consuming for defect classification and impacts the throughput of mask manufacturing. Moreover, higher MEEF leads to stricter mask defect capture criteria so that new generation reticle inspection tool is equipped with better detection capability. Hence, mask process induced defects, which were once undetectable, are now detected and results in the increase of total defect count. Therefore, how to review and characterize reticle defects efficiently is becoming more significant. A new defect review system called ReviewSmart has been developed based on the concept of defect grouping disposition. The review system intelligently bins repeating or similar defects into defect groups and thus allows operators to review massive defects more efficiently. Compared to the conventional defect review method, ReviewSmart not only reduces defect classification time and human judgment error, but also eliminates desensitization that is formerly inevitable. In this study, we attempt to explore the most efficient use of ReviewSmart by evaluating various defect binning conditions. The optimal binning conditions are obtained and have been verified for fidelity qualification through inspection reports (IRs) of production masks. The experiment results help to achieve the best defect classification efficiency when using ReviewSmart in the mask manufacturing and development.
Scanning electron microscope automatic defect classification of process induced defects
NASA Astrophysics Data System (ADS)
Wolfe, Scott; McGarvey, Steve
2017-03-01
With the integration of high speed Scanning Electron Microscope (SEM) based Automated Defect Redetection (ADR) in both high volume semiconductor manufacturing and Research and Development (R and D), the need for reliable SEM Automated Defect Classification (ADC) has grown tremendously in the past few years. In many high volume manufacturing facilities and R and D operations, defect inspection is performed on EBeam (EB), Bright Field (BF) or Dark Field (DF) defect inspection equipment. A comma separated value (CSV) file is created by both the patterned and non-patterned defect inspection tools. The defect inspection result file contains a list of the inspection anomalies detected during the inspection tools' examination of each structure, or the examination of an entire wafers surface for non-patterned applications. This file is imported into the Defect Review Scanning Electron Microscope (DRSEM). Following the defect inspection result file import, the DRSEM automatically moves the wafer to each defect coordinate and performs ADR. During ADR the DRSEM operates in a reference mode, capturing a SEM image at the exact position of the anomalies coordinates and capturing a SEM image of a reference location in the center of the wafer. A Defect reference image is created based on the Reference image minus the Defect image. The exact coordinates of the defect is calculated based on the calculated defect position and the anomalies stage coordinate calculated when the high magnification SEM defect image is captured. The captured SEM image is processed through either DRSEM ADC binning, exporting to a Yield Analysis System (YAS), or a combination of both. Process Engineers, Yield Analysis Engineers or Failure Analysis Engineers will manually review the captured images to insure that either the YAS defect binning is accurately classifying the defects or that the DRSEM defect binning is accurately classifying the defects. This paper is an exploration of the feasibility of the utilization of a Hitachi RS4000 Defect Review SEM to perform Automatic Defect Classification with the objective of the total automated classification accuracy being greater than human based defect classification binning when the defects do not require multiple process step knowledge for accurate classification. The implementation of DRSEM ADC has the potential to improve the response time between defect detection and defect classification. Faster defect classification will allow for rapid response to yield anomalies that will ultimately reduce the wafer and/or the die yield.
Wauters, Lauri D J; Miguel-Moragas, Joan San; Mommaerts, Maurice Y
2015-11-01
To gain insight into the methodology of different computer-aided design-computer-aided manufacturing (CAD-CAM) applications for the reconstruction of cranio-maxillo-facial (CMF) defects. We reviewed and analyzed the available literature pertaining to CAD-CAM for use in CMF reconstruction. We proposed a classification system of the techniques of implant and cutting, drilling, and/or guiding template design and manufacturing. The system consisted of 4 classes (I-IV). These classes combine techniques used for both the implant and template to most accurately describe the methodology used. Our classification system can be widely applied. It should facilitate communication and immediate understanding of the methodology of CAD-CAM applications for the reconstruction of CMF defects.
Defect detection and classification of machined surfaces under multiple illuminant directions
NASA Astrophysics Data System (ADS)
Liao, Yi; Weng, Xin; Swonger, C. W.; Ni, Jun
2010-08-01
Continuous improvement of product quality is crucial to the successful and competitive automotive manufacturing industry in the 21st century. The presence of surface porosity located on flat machined surfaces such as cylinder heads/blocks and transmission cases may allow leaks of coolant, oil, or combustion gas between critical mating surfaces, thus causing damage to the engine or transmission. Therefore 100% inline inspection plays an important role for improving product quality. Although the techniques of image processing and machine vision have been applied to machined surface inspection and well improved in the past 20 years, in today's automotive industry, surface porosity inspection is still done by skilled humans, which is costly, tedious, time consuming and not capable of reliably detecting small defects. In our study, an automated defect detection and classification system for flat machined surfaces has been designed and constructed. In this paper, the importance of the illuminant direction in a machine vision system was first emphasized and then the surface defect inspection system under multiple directional illuminations was designed and constructed. After that, image processing algorithms were developed to realize 5 types of 2D or 3D surface defects (pore, 2D blemish, residue dirt, scratch, and gouge) detection and classification. The steps of image processing include: (1) image acquisition and contrast enhancement (2) defect segmentation and feature extraction (3) defect classification. An artificial machined surface and an actual automotive part: cylinder head surface were tested and, as a result, microscopic surface defects can be accurately detected and assigned to a surface defect class. The cycle time of this system can be sufficiently fast that implementation of 100% inline inspection is feasible. The field of view of this system is 150mm×225mm and the surfaces larger than the field of view can be stitched together in software.
Validity and reliability of the Paprosky acetabular defect classification.
Yu, Raymond; Hofstaetter, Jochen G; Sullivan, Thomas; Costi, Kerry; Howie, Donald W; Solomon, Lucian B
2013-07-01
The Paprosky acetabular defect classification is widely used but has not been appropriately validated. Reliability of the Paprosky system has not been evaluated in combination with standardized techniques of measurement and scoring. This study evaluated the reliability, teachability, and validity of the Paprosky acetabular defect classification. Preoperative radiographs from a random sample of 83 patients undergoing 85 acetabular revisions were classified by four observers, and their classifications were compared with quantitative intraoperative measurements. Teachability of the classification scheme was tested by dividing the four observers into two groups. The observers in Group 1 underwent three teaching sessions; those in Group 2 underwent one session and the influence of teaching on the accuracy of their classifications was ascertained. Radiographic evaluation showed statistically significant relationships with intraoperative measurements of anterior, medial, and superior acetabular defect sizes. Interobserver reliability improved substantially after teaching and did not improve without it. The weighted kappa coefficient went from 0.56 at Occasion 1 to 0.79 after three teaching sessions in Group 1 observers, and from 0.49 to 0.65 after one teaching session in Group 2 observers. The Paprosky system is valid and shows good reliability when combined with standardized definitions of radiographic landmarks and a structured analysis. Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
HVM die yield improvement as a function of DRSEM ADC
NASA Astrophysics Data System (ADS)
Maheshwary, Sonu; Haas, Terry; McGarvey, Steve
2010-03-01
Given the current manufacturing technology roadmap and the competitiveness of the global semiconductor manufacturing environment in conjunction with the semiconductor manufacturing market dynamics, the market place continues to demand a reduced die manufacturing cost. This continuous pressure on lowering die cost in turn drives an aggressive yield learning curve, a key component of which is defect reduction of manufacturing induced anomalies. In order to meet and even exceed line and die yield targets there is a need to revamp defect classification strategies and place a greater emphasize on increasing the accuracy and purity of the Defect Review Scanning Electron Microscope (DRSEM) Automated Defect Classification (ADC) results while placing less emphasis on the ADC results of patterned/un-patterned wafer inspection systems. The increased emphasis on DRSEM ADC results allows for a high degree of automation and consistency in the classification data and eliminates variance induced by the manufacturing staff. This paper examines the use of SEM based Auto Defect Classification in a high volume manufacturing environment as a key driver in the reduction of defect limited yields.
Rule-driven defect detection in CT images of hardwood logs
Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt
2000-01-01
This paper deals with automated detection and identification of internal defects in hardwood logs using computed tomography (CT) images. We have developed a system that employs artificial neural networks to perform tentative classification of logs on a pixel-by-pixel basis. This approach achieves a high level of classification accuracy for several hardwood species (...
Automatic parquet block sorting using real-time spectral classification
NASA Astrophysics Data System (ADS)
Astrom, Anders; Astrand, Erik; Johansson, Magnus
1999-03-01
This paper presents a real-time spectral classification system based on the PGP spectrograph and a smart image sensor. The PGP is a spectrograph which extracts the spectral information from a scene and projects the information on an image sensor, which is a method often referred to as Imaging Spectroscopy. The classification is based on linear models and categorizes a number of pixels along a line. Previous systems adopting this method have used standard sensors, which often resulted in poor performance. The new system, however, is based on a patented near-sensor classification method, which exploits analogue features on the smart image sensor. The method reduces the enormous amount of data to be processed at an early stage, thus making true real-time spectral classification possible. The system has been evaluated on hardwood parquet boards showing very good results. The color defects considered in the experiments were blue stain, white sapwood, yellow decay and red decay. In addition to these four defect classes, a reference class was used to indicate correct surface color. The system calculates a statistical measure for each parquet block, giving the pixel defect percentage. The patented method makes it possible to run at very high speeds with a high spectral discrimination ability. Using a powerful illuminator, the system can run with a line frequency exceeding 2000 line/s. This opens up the possibility to maintain high production speed and still measure with good resolution.
NASA Astrophysics Data System (ADS)
Yathapu, Nithin; McGarvey, Steve; Brown, Justin; Zhivotovsky, Alexander
2016-03-01
This study explores the feasibility of Automated Defect Classification (ADC) with a Surface Scanning Inspection System (SSIS). The defect classification was based upon scattering sensitivity sizing curves created via modeling of the Bidirectional Reflectance Distribution Function (BRDF). The BRDF allowed for the creation of SSIS sensitivity/sizing curves based upon the optical properties of both the filmed wafer samples and the optical architecture of the SSIS. The elimination of Polystyrene Latex Sphere (PSL) and Silica deposition on both filmed and bare Silicon wafers prior to SSIS recipe creation and ADC creates a challenge for light scattering surface intensity based defect binning. This study explored the theoretical maximal SSIS sensitivity based on native defect recipe creation in conjunction with the maximal sensitivity derived from BRDF modeling recipe creation. Single film and film stack wafers were inspected with recipes based upon BRDF modeling. Following SSIS recipe creation, initially targeting maximal sensitivity, selected recipes were optimized to classify defects commonly found on non-patterned wafers. The results were utilized to determine the ADC binning accuracy of the native defects and evaluate the SSIS recipe creation methodology. A statistically valid sample of defects from the final inspection results of each SSIS recipe and filmed substrate were reviewed post SSIS ADC processing on a Defect Review Scanning Electron Microscope (SEM). Native defect images were collected from each statistically valid defect bin category/size for SEM Review. The data collected from the Defect Review SEM was utilized to determine the statistical purity and accuracy of each SSIS defect classification bin. This paper explores both, commercial and technical, considerations of the elimination of PSL and Silica deposition as a precursor to SSIS recipe creation targeted towards ADC. Successful integration of SSIS ADC in conjunction with recipes created via BRDF modeling has the potential to dramatically reduce the workload requirements of a Defect Review SEM and save a significant amount of capital expenditure for 450mm SSIS recipe creation.
Automatic classification of blank substrate defects
NASA Astrophysics Data System (ADS)
Boettiger, Tom; Buck, Peter; Paninjath, Sankaranarayanan; Pereira, Mark; Ronald, Rob; Rost, Dan; Samir, Bhamidipati
2014-10-01
Mask preparation stages are crucial in mask manufacturing, since this mask is to later act as a template for considerable number of dies on wafer. Defects on the initial blank substrate, and subsequent cleaned and coated substrates, can have a profound impact on the usability of the finished mask. This emphasizes the need for early and accurate identification of blank substrate defects and the risk they pose to the patterned reticle. While Automatic Defect Classification (ADC) is a well-developed technology for inspection and analysis of defects on patterned wafers and masks in the semiconductors industry, ADC for mask blanks is still in the early stages of adoption and development. Calibre ADC is a powerful analysis tool for fast, accurate, consistent and automatic classification of defects on mask blanks. Accurate, automated classification of mask blanks leads to better usability of blanks by enabling defect avoidance technologies during mask writing. Detailed information on blank defects can help to select appropriate job-decks to be written on the mask by defect avoidance tools [1][4][5]. Smart algorithms separate critical defects from the potentially large number of non-critical defects or false defects detected at various stages during mask blank preparation. Mechanisms used by Calibre ADC to identify and characterize defects include defect location and size, signal polarity (dark, bright) in both transmitted and reflected review images, distinguishing defect signals from background noise in defect images. The Calibre ADC engine then uses a decision tree to translate this information into a defect classification code. Using this automated process improves classification accuracy, repeatability and speed, while avoiding the subjectivity of human judgment compared to the alternative of manual defect classification by trained personnel [2]. This paper focuses on the results from the evaluation of Automatic Defect Classification (ADC) product at MP Mask Technology Center (MPMask). The Calibre ADC tool was qualified on production mask blanks against the manual classification. The classification accuracy of ADC is greater than 95% for critical defects with an overall accuracy of 90%. The sensitivity to weak defect signals and locating the defect in the images is a challenge we are resolving. The performance of the tool has been demonstrated on multiple mask types and is ready for deployment in full volume mask manufacturing production flow. Implementation of Calibre ADC is estimated to reduce the misclassification of critical defects by 60-80%.
NASA Astrophysics Data System (ADS)
Dwi Cahyono, Bagus; Ainur, Chandra
2018-04-01
The development of science and technology has a direct impact on the preparation of qualified workers, including the preparation of vocational high school graduates. Law Number 20 the Year 2003 on National Education System explains that the purpose of vocational education is to prepare learners to be ready to work in certain fields. One of the learning materials in Vocational High School is welding and detecting welding defects. Introduction of welding and detecting welding defects, one way that can be done is by ultrasonic testing will be very difficult if only capitalize the book only. Therefore this study aims to adopt ultrasonic testing in a computer system. This system is called Delphi Program-based Ultrasonic Testing Expert System. This system is used to determine the classification and type of welding defects of the welded defect indicator knew. In addition to the system, there is a brief explanation of the notion of ultrasonic testing, calibration procedures and inspection procedures ultrasonic testing. In this system, ultrasonic input data testing that shows defects entered into the computer manually. This system is built using Delphi 7 software and Into Set Up Compiler as an installer. The method used in this research is Research and Development (R & D), with the following stages: (1) preliminary research; (2) manufacture of software design; (3) materials collection; (4) early product development; (5) validation of instructional media experts; (6) product analysis and revision; (8) media trials in learning; And (9) result of end product of instructional media. The result of the research shows that: (1) the result of feasibility test according to ultrasonic material testing expert that the system is feasible to be used as instructional media in welding material subject and welding defect detection in vocational education environment, because it contains an explanation about detection method of welding defect using method Ultrasonic testing in detail; (2) feasibility test results according to media experts, that this system has a very attractive visual, user friendly, compatible with windows and Linux and media size that is not too large; And (3) result of test by using data of indication of welding defect in PT PAL Surabaya, obtained classification data of welding defect in accordance with calculation of welding defect classification.
Technical and investigative support for high density digital satellite recording systems
NASA Technical Reports Server (NTRS)
Schultz, R. A.
1982-01-01
Dropout and defect classification are discussed with emphasis on how surface defects responsible for electronic dropouts were identified, what affect various defects could have on the application of tapes to satellite tape recorders (STR), and what type of defects might be field correctable after production of the tape but prior to installation in the STR.
Particle Swarm Optimization approach to defect detection in armour ceramics.
Kesharaju, Manasa; Nagarajah, Romesh
2017-03-01
In this research, various extracted features were used in the development of an automated ultrasonic sensor based inspection system that enables defect classification in each ceramic component prior to despatch to the field. Classification is an important task and large number of irrelevant, redundant features commonly introduced to a dataset reduces the classifiers performance. Feature selection aims to reduce the dimensionality of the dataset while improving the performance of a classification system. In the context of a multi-criteria optimization problem (i.e. to minimize classification error rate and reduce number of features) such as one discussed in this research, the literature suggests that evolutionary algorithms offer good results. Besides, it is noted that Particle Swarm Optimization (PSO) has not been explored especially in the field of classification of high frequency ultrasonic signals. Hence, a binary coded Particle Swarm Optimization (BPSO) technique is investigated in the implementation of feature subset selection and to optimize the classification error rate. In the proposed method, the population data is used as input to an Artificial Neural Network (ANN) based classification system to obtain the error rate, as ANN serves as an evaluator of PSO fitness function. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Paracha, Shazad; Goodman, Eliot; Eynon, Benjamin G.; Noyes, Ben F.; Ha, Steven; Kim, Jong-Min; Lee, Dong-Seok; Lee, Dong-Heok; Cho, Sang-Soo; Ham, Young M.; Vacca, Anthony D.; Fiekowsky, Peter J.; Fiekowsky, Daniel I.
2014-10-01
IC fabs inspect critical masks on a regular basis to ensure high wafer yields. These requalification inspections are costly for many reasons including the capital equipment, system maintenance, and labor costs. In addition, masks typically remain in the "requal" phase for extended, non-productive periods of time. The overall "requal" cycle time in which reticles remain non-productive is challenging to control. Shipping schedules can slip when wafer lots are put on hold until the master critical layer reticle is returned to production. Unfortunately, substituting backup critical layer reticles can significantly reduce an otherwise tightly controlled process window adversely affecting wafer yields. One major requal cycle time component is the disposition process of mask inspections containing hundreds of defects. Not only is precious non-productive time extended by reviewing hundreds of potentially yield-limiting detections, each additional classification increases the risk of manual review techniques accidentally passing real yield limiting defects. Even assuming all defects of interest are flagged by operators, how can any person's judgment be confident regarding lithographic impact of such defects? The time reticles spend away from scanners combined with potential yield loss due to lithographic uncertainty presents significant cycle time loss and increased production costs An automatic defect analysis system (ADAS), which has been in fab production for numerous years, has been improved to handle the new challenges of 14nm node automate reticle defect classification by simulating each defect's printability under the intended illumination conditions. In this study, we have created programmed defects on a production 14nm node critical-layer reticle. These defects have been analyzed with lithographic simulation software and compared to the results of both AIMS optical simulation and to actual wafer prints.
Weak scratch detection and defect classification methods for a large-aperture optical element
NASA Astrophysics Data System (ADS)
Tao, Xian; Xu, De; Zhang, Zheng-Tao; Zhang, Feng; Liu, Xi-Long; Zhang, Da-Peng
2017-03-01
Surface defects on optics cause optic failure and heavy loss to the optical system. Therefore, surface defects on optics must be carefully inspected. This paper proposes a coarse-to-fine detection strategy of weak scratches in complicated dark-field images. First, all possible scratches are detected based on bionic vision. Then, each possible scratch is precisely positioned and connected to a complete scratch by the LSD and a priori knowledge. Finally, multiple scratches with various types can be detected in dark-field images. To classify defects and pollutants, a classification method based on GIST features is proposed. This paper uses many real dark-field images as experimental images. The results show that this method can detect multiple types of weak scratches in complex images and that the defects can be correctly distinguished with interference. This method satisfies the real-time and accurate detection requirements of surface defects.
Ding, Qian; Zhang, Lei; Geraets, Wil; Wu, Wuqing; Zhou, Yongsheng; Wismeijer, Daniel; Xie, Qiufei
The present study aimed to explore the association between marginal bone loss and type of peri-implant bony defect determined using a new peri-implant bony defect classification system. A total of 110 patients with implant-supported mandibular overdentures were involved. Clinical information was collected, including gender, age, smoking habit, and the overdenture attachment system used. Peri-implant bony defect types and marginal distances (ie, distance between the marginal bone level and the top of the implant shoulder) of all sites were identified on panoramic radiographs by a single experienced observer. The associations between marginal distance and peri-implant bony defect type, gender, age, smoking habit, attachment system, and time after implantation were investigated using marginal generalized linear models and regression analysis. A total of 83 participants were included in the final sample with a total of 224 implants involving 3,124 implant sites. The mean observation time was 10.7 years. All peri-implant bony defect types except Type 5 (slit-like) were significantly related to marginal distance in all models (P < .01). Smoking and time after implantation were significantly related to marginal distance while gender, age, and the overdenture attachment system used were not. The peri-implant bony defect type, determined using the new classification system, is associated with the extent of marginal bone loss.
An Analysis of the Magneto-Optic Imaging System
NASA Technical Reports Server (NTRS)
Nath, Shridhar
1996-01-01
The Magneto-Optic Imaging system is being used for the detection of defects in airframes and other aircraft structures. The system has been successfully applied to detecting surface cracks, but has difficulty in the detection of sub-surface defects such as corrosion. The intent of the grant was to understand the physics of the MOI better, in order to use it effectively for detecting corrosion and for classifying surface defects. Finite element analysis, image classification, and image processing are addressed.
Study on on-machine defects measuring system on high power laser optical elements
NASA Astrophysics Data System (ADS)
Luo, Chi; Shi, Feng; Lin, Zhifan; Zhang, Tong; Wang, Guilin
2017-10-01
The influence of surface defects on high power laser optical elements will cause some harm to the performances of imaging system, including the energy consumption and the damage of film layer. To further increase surface defects on high power laser optical element, on-machine defects measuring system was investigated. Firstly, the selection and design are completed by the working condition analysis of the on-machine defects detection system. By designing on processing algorithms to realize the classification recognition and evaluation of surface defects. The calibration experiment of the scratch was done by using the self-made standard alignment plate. Finally, the detection and evaluation of surface defects of large diameter semi-cylindrical silicon mirror are realized. The calibration results show that the size deviation is less than 4% that meet the precision requirement of the detection of the defects. Through the detection of images the on-machine defects detection system can realize the accurate identification of surface defects.
Photomask quality assessment solution for 90-nm technology node
NASA Astrophysics Data System (ADS)
Ohira, Katsumi; Chung, Dong Hoon P.; Nobuyuki, Yoshioka; Tateno, Motonari; Matsumura, Kenichi; Chen, Jiunn-Hung; Luk-Pat, Gerard T.; Fukui, Norio; Tanaka, Yoshio
2004-08-01
As 90 nm LSI devices are about to enter pre-production, the cost and turn-around time of photomasks for such devices will be key factors for success in device production. Such devices will be manufactured with state-of-the-art 193nm photolithography systems. Photomasks for these devices are being produced with the most advanced equipment, material and processing technologies and yet, quality assurance still remains an issue for volume production. These issues include defect classification and disposition due to the insufficient resolution of the defect inspection system at conventional review and classification processes and to aggressive RETs, uncertainty of the impact the defects have on the printed feature as well as inconsistencies of classical defect specifications as applied in the sub-wavelength era are becoming a serious problem. Simulation-based photomask qualification using the Virtual Stepper System is widely accepted today as a reliable mask quality assessment tool of mask defects for both the 180 nm and 130 nm technology nodes. This study examines the extendibility of the Virtual Stepper System to 90nm technology node. The proposed method of simulation-based mask qualification uses aerial image defect simulation in combination with a next generation DUV inspection system with shorter wavelength (266nm) and small pixel size combined with DUV high-resolution microscope for some defect cases. This paper will present experimental results that prove the applicability for enabling 90nm technology nodes. Both contact and line/space patterns with varies programmed defects on ArF Attenuated PSM will be used. This paper will also address how to make the strategy production-worthy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sikora, R.; Chady, T.; Baniukiewicz, P.
2010-02-22
Nondestructive testing and evaluation are under continuous development. Currently researches are concentrated on three main topics: advancement of existing methods, introduction of novel methods and development of artificial intelligent systems for automatic defect recognition (ADR). Automatic defect classification algorithm comprises of two main tasks: creating a defect database and preparing a defect classifier. Here, the database was built using defect features that describe all geometrical and texture properties of the defect. Almost twenty carefully selected features calculated for flaws extracted from real radiograms were used. The radiograms were obtained from shipbuilding industry and they were verified by qualified operator. Twomore » weld defect's classifiers based on artificial neural networks were proposed and compared. First model consisted of one neural network model, where each output neuron corresponded to different defect group. The second model contained five neural networks. Each neural network had one neuron on output and was responsible for detection of defects from one group. In order to evaluate the effectiveness of the neural networks classifiers, the mean square errors were calculated for test radiograms and compared.« less
NASA Astrophysics Data System (ADS)
Sikora, R.; Chady, T.; Baniukiewicz, P.; Caryk, M.; Piekarczyk, B.
2010-02-01
Nondestructive testing and evaluation are under continuous development. Currently researches are concentrated on three main topics: advancement of existing methods, introduction of novel methods and development of artificial intelligent systems for automatic defect recognition (ADR). Automatic defect classification algorithm comprises of two main tasks: creating a defect database and preparing a defect classifier. Here, the database was built using defect features that describe all geometrical and texture properties of the defect. Almost twenty carefully selected features calculated for flaws extracted from real radiograms were used. The radiograms were obtained from shipbuilding industry and they were verified by qualified operator. Two weld defect's classifiers based on artificial neural networks were proposed and compared. First model consisted of one neural network model, where each output neuron corresponded to different defect group. The second model contained five neural networks. Each neural network had one neuron on output and was responsible for detection of defects from one group. In order to evaluate the effectiveness of the neural networks classifiers, the mean square errors were calculated for test radiograms and compared.
Kim, Jeong Tae; Kim, Youn Hwan; Ghanem, Ali M
2015-11-01
Complex defects present structural and functional challenges to reconstructive surgeons. When compared to multiple free flaps or staged reconstruction, the use of chimeric flaps to reconstruct such defects have many advantages such as reduced number of operative procedures and donor site morbidity as well as preservation of recipient vessels. With increased popularity of perforator flaps, chimeric flaps' harvest and design has benefited from 'perforator concept' towards more versatile and better reconstruction solutions. This article discusses perforator based chimeric flaps and presents a practice based classification system that incorporates the perforator flap concept into "Perforator Chimerism". The authors analyzed a variety of chimeric patterns used in 31 consecutive cases to present illustrative case series and their new classification system. Accordingly, chimeric flaps are classified into four types. Type I: Classical Chimerism, Type II: Anastomotic Chimerism, Type III: Perforator Chimerism and Type IV Mixed Chimerism. Types I on specific source vessel anatomy whilst Type II requires microvascular anastomosis to create the chimeric reconstructive solution. Type III chimeric flaps utilizes the perforator concept to raise two components of tissues without microvascular anastomosis between them. Type IV chimeric flaps are mixed type flaps comprising any combination of Types I to III. Incorporation of the perforator concept in planning and designing chimeric flaps has allowed safe, effective and aesthetically superior reconstruction of complex defects. The new classification system aids reconstructive surgeons and trainees to understand chimeric flaps design, facilitating effective incorporation of this important reconstructive technique into the armamentarium of the reconstruction toolbox. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ryu, Sung Jae; Lim, Sung Taek; Vacca, Anthony; Fiekowsky, Peter; Fiekowsky, Dan
2013-09-01
IC fabs inspect critical masks on a regular basis to ensure high wafer yields. These requalification inspections are costly for many reasons including the capital equipment, system maintenance, and labor costs. In addition, masks typically remain in the "requal" phase for extended, non-productive periods of time. The overall "requal" cycle time in which reticles remain non-productive is challenging to control. Shipping schedules can slip when wafer lots are put on hold until the master critical layer reticle is returned to production. Unfortunately, substituting backup critical layer reticles can significantly reduce an otherwise tightly controlled process window adversely affecting wafer yields. One major requal cycle time component is the disposition process of mask inspections containing hundreds of defects. Not only is precious non-productive time extended by reviewing hundreds of potentially yield-limiting detections, each additional classification increases the risk of manual review techniques accidentally passing real yield limiting defects. Even assuming all defects of interest are flagged by operators, how can any person's judgment be confident regarding lithographic impact of such defects? The time reticles spend away from scanners combined with potential yield loss due to lithographic uncertainty presents significant cycle time loss and increased production costs. Fortunately, a software program has been developed which automates defect classification with simulated printability measurement greatly reducing requal cycle time and improving overall disposition accuracy. This product, called ADAS (Auto Defect Analysis System), has been tested in both engineering and high-volume production environments with very successful results. In this paper, data is presented supporting significant reduction for costly wafer print checks, improved inspection area productivity, and minimized risk of misclassified yield limiting defects.
The classification of phocomelia.
Tytherleigh-Strong, G; Hooper, G
2003-06-01
We studied 24 patients with 44 phocomelic upper limbs. Only 11 limbs could be grouped in the classification system of Frantz and O' Rahilly. The non-classifiable limbs were further studied and their characteristics identified. It is confirmed that phocomelia is not an intercalary defect.
Yarn-dyed fabric defect classification based on convolutional neural network
NASA Astrophysics Data System (ADS)
Jing, Junfeng; Dong, Amei; Li, Pengfei; Zhang, Kaibing
2017-09-01
Considering that manual inspection of the yarn-dyed fabric can be time consuming and inefficient, we propose a yarn-dyed fabric defect classification method by using a convolutional neural network (CNN) based on a modified AlexNet. CNN shows powerful ability in performing feature extraction and fusion by simulating the learning mechanism of human brain. The local response normalization layers in AlexNet are replaced by the batch normalization layers, which can enhance both the computational efficiency and classification accuracy. In the training process of the network, the characteristics of the defect are extracted step by step and the essential features of the image can be obtained from the fusion of the edge details with several convolution operations. Then the max-pooling layers, the dropout layers, and the fully connected layers are employed in the classification model to reduce the computation cost and extract more precise features of the defective fabric. Finally, the results of the defect classification are predicted by the softmax function. The experimental results show promising performance with an acceptable average classification rate and strong robustness on yarn-dyed fabric defect classification.
Kesharaju, Manasa; Nagarajah, Romesh
2015-09-01
The motivation for this research stems from a need for providing a non-destructive testing method capable of detecting and locating any defects and microstructural variations within armour ceramic components before issuing them to the soldiers who rely on them for their survival. The development of an automated ultrasonic inspection based classification system would make possible the checking of each ceramic component and immediately alert the operator about the presence of defects. Generally, in many classification problems a choice of features or dimensionality reduction is significant and simultaneously very difficult, as a substantial computational effort is required to evaluate possible feature subsets. In this research, a combination of artificial neural networks and genetic algorithms are used to optimize the feature subset used in classification of various defects in reaction-sintered silicon carbide ceramic components. Initially wavelet based feature extraction is implemented from the region of interest. An Artificial Neural Network classifier is employed to evaluate the performance of these features. Genetic Algorithm based feature selection is performed. Principal Component Analysis is a popular technique used for feature selection and is compared with the genetic algorithm based technique in terms of classification accuracy and selection of optimal number of features. The experimental results confirm that features identified by Principal Component Analysis lead to improved performance in terms of classification percentage with 96% than Genetic algorithm with 94%. Copyright © 2015 Elsevier B.V. All rights reserved.
Defect inspection using a time-domain mode decomposition technique
NASA Astrophysics Data System (ADS)
Zhu, Jinlong; Goddard, Lynford L.
2018-03-01
In this paper, we propose a technique called time-varying frequency scanning (TVFS) to meet the challenges in killer defect inspection. The proposed technique enables the dynamic monitoring of defects by checking the hopping in the instantaneous frequency data and the classification of defect types by comparing the difference in frequencies. The TVFS technique utilizes the bidimensional empirical mode decomposition (BEMD) method to separate the defect information from the sea of system errors. This significantly improve the signal-to-noise ratio (SNR) and moreover, it potentially enables reference-free defect inspection.
A One-Versus-All Class Binarization Strategy for Bearing Diagnostics of Concurrent Defects
Ng, Selina S. Y.; Tse, Peter W.; Tsui, Kwok L.
2014-01-01
In bearing diagnostics using a data-driven modeling approach, a concern is the need for data from all possible scenarios to build a practical model for all operating conditions. This paper is a study on bearing diagnostics with the concurrent occurrence of multiple defect types. The authors are not aware of any work in the literature that studies this practical problem. A strategy based on one-versus-all (OVA) class binarization is proposed to improve fault diagnostics accuracy while reducing the number of scenarios for data collection, by predicting concurrent defects from training data of normal and single defects. The proposed OVA diagnostic approach is evaluated with empirical analysis using support vector machine (SVM) and C4.5 decision tree, two popular classification algorithms frequently applied to system health diagnostics and prognostics. Statistical features are extracted from the time domain and the frequency domain. Prediction performance of the proposed strategy is compared with that of a simple multi-class classification, as well as that of random guess and worst-case classification. We have verified the potential of the proposed OVA diagnostic strategy in performance improvements for single-defect diagnosis and predictions of BPFO plus BPFI concurrent defects using two laboratory-collected vibration data sets. PMID:24419162
A one-versus-all class binarization strategy for bearing diagnostics of concurrent defects.
Ng, Selina S Y; Tse, Peter W; Tsui, Kwok L
2014-01-13
In bearing diagnostics using a data-driven modeling approach, a concern is the need for data from all possible scenarios to build a practical model for all operating conditions. This paper is a study on bearing diagnostics with the concurrent occurrence of multiple defect types. The authors are not aware of any work in the literature that studies this practical problem. A strategy based on one-versus-all (OVA) class binarization is proposed to improve fault diagnostics accuracy while reducing the number of scenarios for data collection, by predicting concurrent defects from training data of normal and single defects. The proposed OVA diagnostic approach is evaluated with empirical analysis using support vector machine (SVM) and C4.5 decision tree, two popular classification algorithms frequently applied to system health diagnostics and prognostics. Statistical features are extracted from the time domain and the frequency domain. Prediction performance of the proposed strategy is compared with that of a simple multi-class classification, as well as that of random guess and worst-case classification. We have verified the potential of the proposed OVA diagnostic strategy in performance improvements for single-defect diagnosis and predictions of BPFO plus BPFI concurrent defects using two laboratory-collected vibration data sets.
On-loom, real-time, noncontact detection of fabric defects by ultrasonic imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chien, H. T.
1998-09-08
A noncontact, on-loom ultrasonic inspection technique was developed for real-time 100% defect inspection of fabrics. A prototype was built and tested successfully on loom. The system is compact, rugged, low cost, requires minimal maintenance, is not sensitive to fabric color and vibration, and can easily be adapted to current loom configurations. Moreover, it can detect defects in both the pick and warp directions. The system is capable of determining the size, location, and orientation of each defect. To further improve the system, air-coupled transducers with higher efficiency and sensitivity need to be developed. Advanced detection algorithms also need to bemore » developed for better classification and categorization of defects in real-time.« less
Classification of Partial Discharge Measured under Different Levels of Noise Contamination.
Jee Keen Raymond, Wong; Illias, Hazlee Azil; Abu Bakar, Ab Halim
2017-01-01
Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.
"SAFEGUARDING THE INTERESTS OF THE STATE" FROM DEFECTIVE DELINQUENT GIRLS.
Sohasky, Kate E
2016-01-01
The 1911 mental classification, "defective delinquent," was created as a temporary legal-medical category in order to identify a peculiar class of delinquent girls in a specific institutional setting. The defective delinquent's alleged slight mental defect, combined with her appearance of normalcy, rendered her a "dangerous" and "incurable" citizen. At the intersection of institutional history and the history of ideas, this article explores the largely overlooked role of borderline mental classifications of near-normalcy in the medicalization of intelligence and criminality during the first third of the twentieth-century United States. Borderline classifications served as mechanisms of control over women's bodies through the criminalization of their minds, and the advent of psychometric tests legitimated and facilitated the spread of this classification beyond its original and intended context. The borderline case of the defective delinquent girl demonstrates the significance of marginal mental classifications to the policing of bodies through the medicalization of intellect. © 2015 Wiley Periodicals, Inc.
Arc-Welding Spectroscopic Monitoring based on Feature Selection and Neural Networks.
Garcia-Allende, P Beatriz; Mirapeix, Jesus; Conde, Olga M; Cobo, Adolfo; Lopez-Higuera, Jose M
2008-10-21
A new spectral processing technique designed for application in the on-line detection and classification of arc-welding defects is presented in this paper. A noninvasive fiber sensor embedded within a TIG torch collects the plasma radiation originated during the welding process. The spectral information is then processed in two consecutive stages. A compression algorithm is first applied to the data, allowing real-time analysis. The selected spectral bands are then used to feed a classification algorithm, which will be demonstrated to provide an efficient weld defect detection and classification. The results obtained with the proposed technique are compared to a similar processing scheme presented in previous works, giving rise to an improvement in the performance of the monitoring system.
An Automated Classification Technique for Detecting Defects in Battery Cells
NASA Technical Reports Server (NTRS)
McDowell, Mark; Gray, Elizabeth
2006-01-01
Battery cell defect classification is primarily done manually by a human conducting a visual inspection to determine if the battery cell is acceptable for a particular use or device. Human visual inspection is a time consuming task when compared to an inspection process conducted by a machine vision system. Human inspection is also subject to human error and fatigue over time. We present a machine vision technique that can be used to automatically identify defective sections of battery cells via a morphological feature-based classifier using an adaptive two-dimensional fast Fourier transformation technique. The initial area of interest is automatically classified as either an anode or cathode cell view as well as classified as an acceptable or a defective battery cell. Each battery cell is labeled and cataloged for comparison and analysis. The result is the implementation of an automated machine vision technique that provides a highly repeatable and reproducible method of identifying and quantifying defects in battery cells.
Reconstruction of maxillectomy and midfacial defects with free tissue transfer.
Santamaria, Eric; Cordeiro, Peter G
2006-11-01
The maxillary bones are part of the midfacial skeleton and are closely related to the eyeglobe, nasal airway, and oral cavity. Together with the overlying soft tissues, the two maxillae are responsible to a large extent for facial contour. Maxillectomy defects become more complex when critical structures such as the orbit, globe, and cranial base are resected, and reconstruction with distant tissues become essential. In this article, we describe a classification system and algorithm for reconstruction of these complex defects using various pedicled and free flaps. Most defects that involve resection of the maxilla and adjacent soft tissues may be classified into one of the following four types: Type I defects, Limited maxillectomy; Type II defects, Subtotal maxillectomy; Type III defects, Total maxillectomy; and Type IV defects, Orbitomaxillectomy. Using this classification, reconstruction of maxillectomy and midfacial defects may be approached considering the relationship between volume and surface area requirements, that is, addressing the bony defect first, followed by assessment of the associated soft tissue, skin, palate, and cheek-lining deficits. In our experience, most complex maxillectomy defects are best reconstructed using free tissue transfer. The rectus abdominis and radial forearm free flap in combination with immediate bone grafting or as an osteocutaneous flap reliably provide the best aesthetic and functional results. A temporalis muscle pedicled flap is used for reconstruction of maxillectomy defects only in those patients who are not candidates for a microsurgical procedure.
Reconstruction Using Locoregional Flaps for Large Skull Base Defects.
Hatano, Takaharu; Motomura, Hisashi; Ayabe, Shinobu
2015-06-01
We present a modified locoregional flap for the reconstruction of large anterior skull base defects that should be reconstructed with a free flap according to Yano's algorithm. No classification of skull base defects had been proposed for a long time. Yano et al suggested a new classification in 2012. The lb defect of Yano's classification extends horizontally from the cribriform plate to the orbital roof. According to Yano's algorithm for subsequent skull base reconstructive procedures, a lb defect should be reconstructed with a free flap such as an anterolateral thigh free flap or rectus abdominis myocutaneous free flap. However, our modified locoregional flap has also enabled reconstruction of lb defects. In this case series, we used a locoregional flap for lb defects. No major postoperative complications occurred. We present our modified locoregional flap that enables reconstruction of lb defects.
Classification of Partial Discharge Measured under Different Levels of Noise Contamination
2017-01-01
Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination. PMID:28085953
Infrared machine vision system for the automatic detection of olive fruit quality.
Guzmán, Elena; Baeten, Vincent; Pierna, Juan Antonio Fernández; García-Mesa, José A
2013-11-15
External quality is an important factor in the extraction of olive oil and the marketing of olive fruits. The appearance and presence of external damage are factors that influence the quality of the oil extracted and the perception of consumers, determining the level of acceptance prior to purchase in the case of table olives. The aim of this paper is to report on artificial vision techniques developed for the online estimation of olive quality and to assess the effectiveness of these techniques in evaluating quality based on detecting external defects. This method of classifying olives according to the presence of defects is based on an infrared (IR) vision system. Images of defects were acquired using a digital monochrome camera with band-pass filters on near-infrared (NIR). The original images were processed using segmentation algorithms, edge detection and pixel value intensity to classify the whole fruit. The detection of the defect involved a pixel classification procedure based on nonparametric models of the healthy and defective areas of olives. Classification tests were performed on olives to assess the effectiveness of the proposed method. This research showed that the IR vision system is a useful technology for the automatic assessment of olives that has the potential for use in offline inspection and for online sorting for defects and the presence of surface damage, easily distinguishing those that do not meet minimum quality requirements. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.
Evolutionary fuzzy ARTMAP neural networks for classification of semiconductor defects.
Tan, Shing Chiang; Watada, Junzo; Ibrahim, Zuwairie; Khalid, Marzuki
2015-05-01
Wafer defect detection using an intelligent system is an approach of quality improvement in semiconductor manufacturing that aims to enhance its process stability, increase production capacity, and improve yields. Occasionally, only few records that indicate defective units are available and they are classified as a minority group in a large database. Such a situation leads to an imbalanced data set problem, wherein it engenders a great challenge to deal with by applying machine-learning techniques for obtaining effective solution. In addition, the database may comprise overlapping samples of different classes. This paper introduces two models of evolutionary fuzzy ARTMAP (FAM) neural networks to deal with the imbalanced data set problems in a semiconductor manufacturing operations. In particular, both the FAM models and hybrid genetic algorithms are integrated in the proposed evolutionary artificial neural networks (EANNs) to classify an imbalanced data set. In addition, one of the proposed EANNs incorporates a facility to learn overlapping samples of different classes from the imbalanced data environment. The classification results of the proposed evolutionary FAM neural networks are presented, compared, and analyzed using several classification metrics. The outcomes positively indicate the effectiveness of the proposed networks in handling classification problems with imbalanced data sets.
Chungsomprasong, Paweena; Bositthipichet, Densiri; Ketsara, Salisa; Titaram, Yuttapon; Chanthong, Prakul; Kanjanauthai, Supaluck
2018-01-01
Objective To compare survival of patients with newly diagnosed pulmonary arterial hypertension associated with congenital heart disease (PAH-CHD) according to various clinical classifications with classifications of anatomical-pathophysiological systemic to pulmonary shunts in a single-center cohort. Methods All prevalent cases of PAH-CHD with hemodynamic confirmation by cardiac catheterization in 1995–2015 were retrospectively reviewed. Patients who were younger than three months of age, or with single ventricle following surgery were excluded. Baseline characteristics and clinical outcomes were retrieved from the database. The survival analysis was performed at the end of 2016. Prognostic factors were identified using multivariate analysis. Results A total of 366 consecutive patients (24.5 ± 17.6 years of age, 40% male) with PAH-CHD were analyzed. Most had simple shunts (85 pre-tricuspid, 105 post-tricuspid, 102 combined shunts). Patients with pre-tricuspid shunts were significantly older at diagnosis in comparison to post-tricuspid, combined, and complex shunts. Clinical classifications identified patients as having Eisenmenger syndrome (ES, 26.8%), prevalent left to right shunt (66.7%), PAH with small defect (3%), or PAH following defect correction (3.5%). At follow-up (median = 5.9 years; 0.1–20.7 years), no statistically significant differences in survival rate were seen among the anatomical-pathophysiological shunts (p = 0.1). Conversely, the clinical classifications revealed that patients with PAH-small defect had inferior survival compared to patients with ES, PAH post-corrective surgery, or PAH with prevalent left to right shunt (p = 0.01). Significant mortality risks were functional class III, age < 10 years, PAH-small defect, elevated right atrial pressure > 15 mmHg, and baseline PVR > 8 WU•m.2 Conclusion Patients with PAH-CHD had a modest long-term survival. Different anatomical-pathophysiological shunts affect the natural presentation, while clinical classifications indicate treatment strategies and survival. Contemporary therapy improves survival in deliberately selected patients. PMID:29664959
High-speed potato grading and quality inspection based on a color vision system
NASA Astrophysics Data System (ADS)
Noordam, Jacco C.; Otten, Gerwoud W.; Timmermans, Toine J. M.; van Zwol, Bauke H.
2000-03-01
A high-speed machine vision system for the quality inspection and grading of potatoes has been developed. The vision system grades potatoes on size, shape and external defects such as greening, mechanical damages, rhizoctonia, silver scab, common scab, cracks and growth cracks. A 3-CCD line-scan camera inspects the potatoes in flight as they pass under the camera. The use of mirrors to obtain a 360-degree view of the potato and the lack of product holders guarantee a full view of the potato. To achieve the required capacity of 12 tons/hour, 11 SHARC Digital Signal Processors perform the image processing and classification tasks. The total capacity of the system is about 50 potatoes/sec. The color segmentation procedure uses Linear Discriminant Analysis (LDA) in combination with a Mahalanobis distance classifier to classify the pixels. The procedure for the detection of misshapen potatoes uses a Fourier based shape classification technique. Features such as area, eccentricity and central moments are used to discriminate between similar colored defects. Experiments with red and yellow skin-colored potatoes have shown that the system is robust and consistent in its classification.
An open-architecture approach to defect analysis software for mask inspection systems
NASA Astrophysics Data System (ADS)
Pereira, Mark; Pai, Ravi R.; Reddy, Murali Mohan; Krishna, Ravi M.
2009-04-01
Industry data suggests that Mask Inspection represents the second biggest component of Mask Cost and Mask Turn Around Time (TAT). Ever decreasing defect size targets lead to more sensitive mask inspection across the chip, thus generating too many defects. Hence, more operator time is being spent in analyzing and disposition of defects. Also, the fact that multiple Mask Inspection Systems and Defect Analysis strategies would typically be in use in a Mask Shop or a Wafer Foundry further complicates the situation. In this scenario, there is a need for a versatile, user friendly and extensible Defect Analysis software that reduces operator analysis time and enables correct classification and disposition of mask defects by providing intuitive visual and analysis aids. We propose a new vendor-neutral defect analysis software, NxDAT, based on an open architecture. The open architecture of NxDAT makes it easily extensible to support defect analysis for mask inspection systems from different vendors. The capability to load results from mask inspection systems from different vendors either directly or through a common interface enables the functionality of establishing correlation between inspections carried out by mask inspection systems from different vendors. This capability of NxDAT enhances the effectiveness of defect analysis as it directly addresses the real-life scenario where multiple types of mask inspection systems from different vendors co-exist in mask shops or wafer foundries. The open architecture also potentially enables loading wafer inspection results as well as loading data from other related tools such as Review Tools, Repair Tools, CD-SEM tools etc, and correlating them with the corresponding mask inspection results. A unique concept of Plug-In interface to NxDAT further enhances the openness of the architecture of NxDAT by enabling end-users to add their own proprietary defect analysis and image processing algorithms. The plug-in interface makes it possible for the end-users to make use of their collected knowledge through the years of experience in mask inspection process by encapsulating the knowledge into software utilities and plugging them into NxDAT. The plug-in interface is designed with the intent of enabling the pro-active mask defect analysis teams to build competitive differentiation into their defect analysis process while protecting their knowledge internally within their company. By providing interface with all major standard layout and mask data formats, NxDAT enables correlation of defect data on reticles with design and mask databases, further extending the effectiveness of defect analysis for D2DB inspection. NxDAT also includes many other advanced features for easy and fast navigation, visual display of defects, defect selection, multi-tier classification, defect clustering and gridding, sophisticated CD and contact measurement analysis, repeatability analysis such as adder analysis, defect trend, capture rate etc.
Studer, S; Naef, R; Schärer, P
1997-12-01
Esthetically correct treatment of a localized alveolar ridge defect is a frequent prosthetic challenge. Such defects can be overcome not only by a variety of prosthetic means, but also by several periodontal surgical techniques, notably soft tissue augmentations. Preoperative classification of the localized alveolar ridge defect can be greatly useful in evaluating the prognosis and technical difficulties involved. A semiquantitative classification, dependent on the severity of vertical and horizontal dimensional loss, is proposed to supplement the recognized qualitative classification of a ridge defect. Various methods of soft tissue augmentation are evaluated, based on initial volumetric measurements. The roll flap technique is proposed when the problem is related to ridge quality (single-tooth defect with little horizontal and vertical loss). Larger defects in which a volumetric problem must be solved are corrected through the subepithelial connective tissue technique. Additional mucogingival problems (eg, insufficient gingival width, high frenum, gingival scarring, or tattoo) should not be corrected simultaneously with augmentation procedures. In these cases, the onlay transplant technique is favored.
Cho, Jeong-Seok; Bae, Hyung-Jin; Cho, Byoung-Kwan; Moon, Kwang-Deog
2017-04-01
Qualitative properties of roasting defect coffee beans and their classification methods were studied using hyperspectral imaging (HSI). The roasting defect beans were divided into 5 groups: medium roasting (Cont), under developed (RD-1), over roasting (RD-2), interior under developed (RD-3), and interior scorching (RD-4). The following qualitative properties were assayed: browning index (BI), moisture content (MC), chlorogenic acid (CA), trigonelline (TG), and caffeine (CF) content. Their HSI spectra (1000-1700nm) were also analysed to develop the classification methods of roasting defect beans. RD-2 showed the highest BI and the lowest MC, CA, and TG content. The accuracy of classification model of partial least-squares discriminant was 86.2%. The most powerful wavelength to classify the defective beans was approximately 1420nm (related to OH bond). The HSI reflectance values at 1420nm showed similar tendency with MC, enabling the use of this technology to classify the roasting defect beans. Copyright © 2016. Published by Elsevier Ltd.
Advanced defect classification by smart sampling, based on sub-wavelength anisotropic scatterometry
NASA Astrophysics Data System (ADS)
van der Walle, Peter; Kramer, Esther; Ebeling, Rob; Spruit, Helma; Alkemade, Paul; Pereira, Silvania; van der Donck, Jacques; Maas, Diederik
2018-03-01
We report on advanced defect classification using TNO's RapidNano particle scanner. RapidNano was originally designed for defect detection on blank substrates. In detection-mode, the RapidNano signal from nine azimuth angles is added for sensitivity. In review-mode signals from individual angles are analyzed to derive additional defect properties. We define the Fourier coefficient parameter space that is useful to study the statistical variation in defect types on a sample. By selecting defects from each defect type for further review by SEM, information on all defects can be obtained efficiently.
Real-time color-based texture analysis for sophisticated defect detection on wooden surfaces
NASA Astrophysics Data System (ADS)
Polzleitner, Wolfgang; Schwingshakl, Gert
2004-10-01
We describe a scanning system developed for the classification and grading of surfaces of wooden tiles. The system uses color imaging sensors to analyse the surfaces of either hard- or softwood material in terms of the texture formed by grain lines (orientation, spatial frequency, and color), various types of colorization, and other defects like knots, heart wood, cracks, holes, etc. The analysis requires two major tracks: the assignment of a tile to its texture class (like A, B, C, 1, 2, 3, Waste), and the detection of defects that decrease the commercial value of the tile (heart wood, knots, etc.). The system was initially developed under the international IMS program (Intelligent Manufacturing Systems) by an industry consortium. During the last two years it has been further developed, and several industrial systems have been installed, and are presently used in production of hardwood flooring. The methods implemented reflect some of the latest developments in the field of pattern recognition: genetic feature selection, two-dimensional second order statistics, special color space transforms, and classification by neural networks. In the industrial scenario we describe, many of the features defining a class cannot be described mathematically. Consequently a focus was the design of a learning architecture, where prototype texture samples are presented to the system, which then automatically finds the internal representation necessary for classification. The methods used in this approach have a wide applicability to problems of inspection, sorting, and optimization of high-value material typically used in the furniture, flooring, and related wood manufacturing industries.
Developmental defects in zebrafish for classification of EGF pathway inhibitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pruvot, Benoist; Curé, Yoann; Djiotsa, Joachim
2014-01-15
One of the major challenges when testing drug candidates targeted at a specific pathway in whole animals is the discrimination between specific effects and unwanted, off-target effects. Here we used the zebrafish to define several developmental defects caused by impairment of Egf signaling, a major pathway of interest in tumor biology. We inactivated Egf signaling by genetically blocking Egf expression or using specific inhibitors of the Egf receptor function. We show that the combined occurrence of defects in cartilage formation, disturbance of blood flow in the trunk and a decrease of myelin basic protein expression represent good indicators for impairmentmore » of Egf signaling. Finally, we present a classification of known tyrosine kinase inhibitors according to their specificity for the Egf pathway. In conclusion, we show that developmental indicators can help to discriminate between specific effects on the target pathway from off-target effects in molecularly targeted drug screening experiments in whole animal systems. - Highlights: • We analyze the functions of Egf signaling on zebrafish development. • Genetic blocking of Egf expression causes cartilage, myelin and circulatory defects. • Chemical inhibition of Egf receptor function causes similar defects. • Developmental defects can reveal the specificity of Egf pathway inhibitors.« less
High-throughput automatic defect review for 300mm blank wafers with atomic force microscope
NASA Astrophysics Data System (ADS)
Zandiatashbar, Ardavan; Kim, Byong; Yoo, Young-kook; Lee, Keibock; Jo, Ahjin; Lee, Ju Suk; Cho, Sang-Joon; Park, Sang-il
2015-03-01
While feature size in lithography process continuously becomes smaller, defect sizes on blank wafers become more comparable to device sizes. Defects with nm-scale characteristic size could be misclassified by automated optical inspection (AOI) and require post-processing for proper classification. Atomic force microscope (AFM) is known to provide high lateral and the highest vertical resolution by mechanical probing among all techniques. However, its low throughput and tip life in addition to the laborious efforts for finding the defects have been the major limitations of this technique. In this paper we introduce automatic defect review (ADR) AFM as a post-inspection metrology tool for defect study and classification for 300 mm blank wafers and to overcome the limitations stated above. The ADR AFM provides high throughput, high resolution, and non-destructive means for obtaining 3D information for nm-scale defect review and classification.
Yarn-dyed fabric defect classification based on convolutional neural network
NASA Astrophysics Data System (ADS)
Jing, Junfeng; Dong, Amei; Li, Pengfei
2017-07-01
Considering that the manual inspection of the yarn-dyed fabric can be time consuming and less efficient, a convolutional neural network (CNN) solution based on the modified AlexNet structure for the classification of the yarn-dyed fabric defect is proposed. CNN has powerful ability of feature extraction and feature fusion which can simulate the learning mechanism of the human brain. In order to enhance computational efficiency and detection accuracy, the local response normalization (LRN) layers in AlexNet are replaced by the batch normalization (BN) layers. In the process of the network training, through several convolution operations, the characteristics of the image are extracted step by step, and the essential features of the image can be obtained from the edge features. And the max pooling layers, the dropout layers, the fully connected layers are also employed in the classification model to reduce the computation cost and acquire more precise features of fabric defect. Finally, the results of the defect classification are predicted by the softmax function. The experimental results show the capability of defect classification via the modified Alexnet model and indicate its robustness.
Wavelet packet-based insufficiency murmurs analysis method
NASA Astrophysics Data System (ADS)
Choi, Samjin; Jiang, Zhongwei
2007-12-01
In this paper, the aortic and mitral insufficiency murmurs analysis method using the wavelet packet technique is proposed for classifying the valvular heart defects. Considering the different frequency distributions between the normal sound and insufficiency murmurs in frequency domain, we used two properties such as the relative wavelet energy and the Shannon wavelet entropy which described the energy information and the entropy information at the selected frequency band, respectively. Then, the signal to murmur ratio (SMR) measures which could mean the ratio between the frequency bands for normal heart sounds and for aortic and mitral insufficiency murmurs allocated to 15.62-187.50 Hz and 187.50-703.12 Hz respectively, were employed as a classification manner to identify insufficiency murmurs. The proposed measures were validated by some case studies. The 194 heart sound signals with 48 normal and 146 abnormal sound cases acquired from 6 healthy volunteers and 30 patients were tested. The normal sound signals recorded by applying a self-produced wireless electric stethoscope system to subjects with no history of other heart complications were used. Insufficiency murmurs were grouped into two valvular heart defects such as aortic insufficiency and mitral insufficiency. These murmur subjects included no other coexistent valvular defects. As a result, the proposed insufficiency murmurs detection method showed relatively very high classification efficiency. Therefore, the proposed heart sound classification method based on the wavelet packet was validated for the classification of valvular heart defects, especially insufficiency murmurs.
NASA Astrophysics Data System (ADS)
Mirapeix, J.; García-Allende, P. B.; Cobo, A.; Conde, O.; López-Higuera, J. M.
2007-07-01
A new spectral processing technique designed for its application in the on-line detection and classification of arc-welding defects is presented in this paper. A non-invasive fiber sensor embedded within a TIG torch collects the plasma radiation originated during the welding process. The spectral information is then processed by means of two consecutive stages. A compression algorithm is first applied to the data allowing real-time analysis. The selected spectral bands are then used to feed a classification algorithm, which will be demonstrated to provide an efficient weld defect detection and classification. The results obtained with the proposed technique are compared to a similar processing scheme presented in a previous paper, giving rise to an improvement in the performance of the monitoring system.
Fan, Mengbao; Wang, Qi; Cao, Binghua; Ye, Bo; Sunny, Ali Imam; Tian, Guiyun
2016-01-01
Eddy current testing is quite a popular non-contact and cost-effective method for nondestructive evaluation of product quality and structural integrity. Excitation frequency is one of the key performance factors for defect characterization. In the literature, there are many interesting papers dealing with wide spectral content and optimal frequency in terms of detection sensitivity. However, research activity on frequency optimization with respect to characterization performances is lacking. In this paper, an investigation into optimum excitation frequency has been conducted to enhance surface defect classification performance. The influences of excitation frequency for a group of defects were revealed in terms of detection sensitivity, contrast between defect features, and classification accuracy using kernel principal component analysis (KPCA) and a support vector machine (SVM). It is observed that probe signals are the most sensitive on the whole for a group of defects when excitation frequency is set near the frequency at which maximum probe signals are retrieved for the largest defect. After the use of KPCA, the margins between the defect features are optimum from the perspective of the SVM, which adopts optimal hyperplanes for structure risk minimization. As a result, the best classification accuracy is obtained. The main contribution is that the influences of excitation frequency on defect characterization are interpreted, and experiment-based procedures are proposed to determine the optimal excitation frequency for a group of defects rather than a single defect with respect to optimal characterization performances. PMID:27164112
Fan, Mengbao; Wang, Qi; Cao, Binghua; Ye, Bo; Sunny, Ali Imam; Tian, Guiyun
2016-05-07
Eddy current testing is quite a popular non-contact and cost-effective method for nondestructive evaluation of product quality and structural integrity. Excitation frequency is one of the key performance factors for defect characterization. In the literature, there are many interesting papers dealing with wide spectral content and optimal frequency in terms of detection sensitivity. However, research activity on frequency optimization with respect to characterization performances is lacking. In this paper, an investigation into optimum excitation frequency has been conducted to enhance surface defect classification performance. The influences of excitation frequency for a group of defects were revealed in terms of detection sensitivity, contrast between defect features, and classification accuracy using kernel principal component analysis (KPCA) and a support vector machine (SVM). It is observed that probe signals are the most sensitive on the whole for a group of defects when excitation frequency is set near the frequency at which maximum probe signals are retrieved for the largest defect. After the use of KPCA, the margins between the defect features are optimum from the perspective of the SVM, which adopts optimal hyperplanes for structure risk minimization. As a result, the best classification accuracy is obtained. The main contribution is that the influences of excitation frequency on defect characterization are interpreted, and experiment-based procedures are proposed to determine the optimal excitation frequency for a group of defects rather than a single defect with respect to optimal characterization performances.
Sinha, S K; Karray, F
2002-01-01
Pipeline surface defects such as holes and cracks cause major problems for utility managers, particularly when the pipeline is buried under the ground. Manual inspection for surface defects in the pipeline has a number of drawbacks, including subjectivity, varying standards, and high costs. Automatic inspection system using image processing and artificial intelligence techniques can overcome many of these disadvantages and offer utility managers an opportunity to significantly improve quality and reduce costs. A recognition and classification of pipe cracks using images analysis and neuro-fuzzy algorithm is proposed. In the preprocessing step the scanned images of pipe are analyzed and crack features are extracted. In the classification step the neuro-fuzzy algorithm is developed that employs a fuzzy membership function and error backpropagation algorithm. The idea behind the proposed approach is that the fuzzy membership function will absorb variation of feature values and the backpropagation network, with its learning ability, will show good classification efficiency.
Detection of defects on apple using B-spline lighting correction method
NASA Astrophysics Data System (ADS)
Li, Jiangbo; Huang, Wenqian; Guo, Zhiming
To effectively extract defective areas in fruits, the uneven intensity distribution that was produced by the lighting system or by part of the vision system in the image must be corrected. A methodology was used to convert non-uniform intensity distribution on spherical objects into a uniform intensity distribution. A basically plane image with the defective area having a lower gray level than this plane was obtained by using proposed algorithms. Then, the defective areas can be easily extracted by a global threshold value. The experimental results with a 94.0% classification rate based on 100 apple images showed that the proposed algorithm was simple and effective. This proposed method can be applied to other spherical fruits.
NASA Astrophysics Data System (ADS)
Xiao, Zhitao; Leng, Yanyi; Geng, Lei; Xi, Jiangtao
2018-04-01
In this paper, a new convolution neural network method is proposed for the inspection and classification of galvanized stamping parts. Firstly, all workpieces are divided into normal and defective by image processing, and then the defective workpieces extracted from the region of interest (ROI) area are input to the trained fully convolutional networks (FCN). The network utilizes an end-to-end and pixel-to-pixel training convolution network that is currently the most advanced technology in semantic segmentation, predicts result of each pixel. Secondly, we mark the different pixel values of the workpiece, defect and background for the training image, and use the pixel value and the number of pixels to realize the recognition of the defects of the output picture. Finally, the defect area's threshold depended on the needs of the project is set to achieve the specific classification of the workpiece. The experiment results show that the proposed method can successfully achieve defect detection and classification of galvanized stamping parts under ordinary camera and illumination conditions, and its accuracy can reach 99.6%. Moreover, it overcomes the problem of complex image preprocessing and difficult feature extraction and performs better adaptability.
Distribution of female genital tract anomalies in two classifications.
Heinonen, Pentti K
2016-11-01
This study assessed the distribution of Müllerian duct anomalies in two verified classifications of female genital tract malformations, and the presence of associated renal defects. 621 women with confirmed female genital tract anomalies were retrospectively grouped under the European (ESHRE/ESGE) and the American (AFS) classification. The diagnosis of uterine malformation was based on findings in hysterosalpingography, two-dimensional ultrasonography, endoscopies, laparotomy, cesarean section and magnetic resonance imaging in 97.3% of cases. Renal status was determined in 378 patients, including 5 with normal uterus and vagina. The European classification covered all 621 women studied. Uterine anomalies without cervical or vaginal anomaly were found in 302 (48.6%) patients. Uterine anomaly was associated with vaginal anomaly in 45.2%, and vaginal anomaly alone was found in 26 (4.2%) cases. Septate uterus was the most common (49.1%) of all genital tract anomalies, followed by bicorporeal uteri (18.2%). The American classification covered 590 (95%) out of the 621 women with genital tract anomalies. The American system did not take into account vaginal anomalies in 170 (34.7%) and cervical anomalies in 174 (35.5%) out of 490 cases with uterine malformations. Renal abnormalities were found in 71 (18.8%) out of 378 women, unilateral renal agenesis being the most common defect (12.2%), also found in 4 women without Müllerian duct anomaly. The European classification sufficiently covered uterine and vaginal abnormalities. The distribution of the main uterine anomalies was equal in both classifications. The American system missed cervical and vaginal anomalies associated with uterine anomalies. Evaluation of renal system is recommended for all patients with genital tract anomalies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Regenerative Medicine for Battlefield Injuries
2013-10-01
across a critical size defect (CSD) in the fibula, using the axolotl , Abystoma mexicanum as a model system. The scope of the research is to...successful because they initiated the whole cascade of events required for cartilage development. These results indicate that the axolotl fibula can be used...TERMS Regeneration across a critical size defect in axolotl fibula, efficacy of growth factor combinations 16. SECURITY CLASSIFICATION OF: 17
Velidedeoglu, Mehmet; Arikan, Akif Enes; Uludag, Sezgin Server; Olgun, Deniz Cebi; Kilic, Fahrettin; Kapan, Metin
2015-05-01
Due to being a severe complication, iatrogenic bile duct injury is still a challenging issue for surgeons in gallbladder surgery. However, a commonly accepted classification describing the type of injury has not been available yet. This study aims to evaluate ability of six current classification systems to discriminate bile duct injury patterns. Twelve patients, who were referred to our clinic because of iatrogenic bile duct injury after laparoscopic cholecystectomy were reviewed retrospectively. We described type of injury for each patient according to current six different classifications. 9 patients underwent definitive biliary reconstruction. Bismuth, Strasberg-Bismuth, Stewart-Way and Neuhaus classifications do not consider vascular involvement, Siewert system does, but only for the tangential lesions without structural loss of duct and lesion with a structural defect of hepatic or common bile duct. Siewert, Neuhaus and Stewart-Way systems do not discriminate between lesions at or above bifurcation of the hepatic duct. The Hannover classification may resolve the missing aspects of other systems by describing additional vascular involvement and location of the lesion at or above bifurcation.
Strongly localized donor level in oxygen doped gallium nitride
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetzel, C.; Suski, T.; Ager, J.W. III
1996-08-01
A classification in terms of localization of donor defects in GaN is performed by Raman spectroscopy under large hydrostatic pressure. We observe a significant decrease of free carrier concentration in highly O doped GaN epitaxial films at 22 GPa, indicating the presence of a strongly localized donor defect at large pressure. Monitoring the phonon plasmon coupled mode, we find similarities with results on highly n-type bulk crystals. We refine the model of localized defects in GaN and transfer it to the AlGaN system.
Real-time ultrasonic weld evaluation system
NASA Astrophysics Data System (ADS)
Katragadda, Gopichand; Nair, Satish; Liu, Harry; Brown, Lawrence M.
1996-11-01
Ultrasonic testing techniques are currently used as an alternative to radiography for detecting, classifying,and sizing weld defects, and for evaluating weld quality. Typically, ultrasonic weld inspections are performed manually, which require significant operator expertise and time. Thus, in recent years, the emphasis is to develop automated methods to aid or replace operators in critical weld inspections where inspection time, reliability, and operator safety are major issues. During this period, significant advances wee made in the areas of weld defect classification and sizing. Very few of these methods, however have found their way into the market, largely due to the lack of an integrated approach enabling real-time implementation. Also, not much research effort was directed in improving weld acceptance criteria. This paper presents an integrated system utilizing state-of-the-art techniques for a complete automation of the weld inspection procedure. The modules discussed include transducer tracking, classification, sizing, and weld acceptance criteria. Transducer tracking was studied by experimentally evaluating sonic and optical position tracking techniques. Details for this evaluation are presented. Classification is obtained using a multi-layer perceptron. Results from different feature extraction schemes, including a new method based on a combination of time and frequency-domain signal representations are given. Algorithms developed to automate defect registration and sizing are discussed. A fuzzy-logic acceptance criteria for weld acceptance is presented describing how this scheme provides improved robustness compared to the traditional flow-diagram standards.
Inline inspection of textured plastics surfaces
NASA Astrophysics Data System (ADS)
Michaeli, Walter; Berdel, Klaus
2011-02-01
This article focuses on the inspection of plastics web materials exhibiting irregular textures such as imitation wood or leather. They are produced in a continuous process at high speed. In this process, various defects occur sporadically. However, current inspection systems for plastics surfaces are able to inspect unstructured products or products with regular, i.e., highly periodic, textures, only. The proposed inspection algorithm uses the local binary pattern operator for texture feature extraction. For classification, semisupervised as well as supervised approaches are used. A simple concept for semisupervised classification is presented and applied for defect detection. The resulting defect-maps are presented to the operator. He assigns class labels that are used to train the supervised classifier in order to distinguish between different defect types. A concept for parallelization is presented allowing the efficient use of standard multicore processor PC hardware. Experiments with images of a typical product acquired in an industrial setting show a detection rate of 97% while achieving a false alarm rate below 1%. Real-time tests show that defects can be reliably detected even at haul-off speeds of 30 m/min. Further applications of the presented concept can be found in the inspection of other materials.
Automatic casting surface defect recognition and classification
NASA Astrophysics Data System (ADS)
Wong, Boon K.; Elliot, M. P.; Rapley, C. W.
1995-03-01
High integrity castings require surfaces free from defects to reduce, if not eliminate, vulnerability to component failure from such as physical or thermal fatigue or corrosion attack. Previous studies have shown that defects on casting surfaces can be optically enhanced from the surrounding randomly textured surface by liquid penetrants, magnetic particle and other methods. However, very little has been reported on recognition and classification of the defects. The basic problem is one of shape recognition and classification, where the shape can vary in size and orientation as well as in actual shape generally within an envelope that classifies it as a particular defect. The initial work done towards this has focused on recognizing and classifying standard shapes such as the circle, square, rectangle and triangle. Various approaches were tried and this led eventually to a series of fuzzy logic based algorithms from which very good results were obtained. From this work fuzzy logic memberships were generated for the detection of defects found on casting surfaces. Simulated model shapes of such as the quench crack, mechanical crack and hole have been used to test the generated algorithm and the results for recognition and classification are very encouraging.
Research on defects inspection of solder balls based on eddy current pulsed thermography.
Zhou, Xiuyun; Zhou, Jinlong; Tian, Guiyun; Wang, Yizhe
2015-10-13
In order to solve tiny defect detection for solder balls in high-density flip-chip, this paper proposed feasibility study on the effect of detectability as well as classification based on eddy current pulsed thermography (ECPT). Specifically, numerical analysis of 3D finite element inductive heat model is generated to investigate disturbance on the temperature field for different kind of defects such as cracks, voids, etc. The temperature variation between defective and non-defective solder balls is monitored for defects identification and classification. Finally, experimental study is carried on the diameter 1mm tiny solder balls by using ECPT and verify the efficacy of the technique.
NASA Astrophysics Data System (ADS)
McClanahan, James Patrick
Eddy Current Testing (ECT) is a Non-Destructive Examination (NDE) technique that is widely used in power generating plants (both nuclear and fossil) to test the integrity of heat exchanger (HX) and steam generator (SG) tubing. Specifically for this research, laboratory-generated, flawed tubing data were examined. The purpose of this dissertation is to develop and implement an automated method for the classification and an advanced characterization of defects in HX and SG tubing. These two improvements enhanced the robustness of characterization as compared to traditional bobbin-coil ECT data analysis methods. A more robust classification and characterization of the tube flaw in-situ (while the SG is on-line but not when the plant is operating), should provide valuable information to the power industry. The following are the conclusions reached from this research. A feature extraction program acquiring relevant information from both the mixed, absolute and differential data was successfully implemented. The CWT was utilized to extract more information from the mixed, complex differential data. Image Processing techniques used to extract the information contained in the generated CWT, classified the data with a high success rate. The data were accurately classified, utilizing the compressed feature vector and using a Bayes classification system. An estimation of the upper bound for the probability of error, using the Bhattacharyya distance, was successfully applied to the Bayesian classification. The classified data were separated according to flaw-type (classification) to enhance characterization. The characterization routine used dedicated, flaw-type specific ANNs that made the characterization of the tube flaw more robust. The inclusion of outliers may help complete the feature space so that classification accuracy is increased. Given that the eddy current test signals appear very similar, there may not be sufficient information to make an extremely accurate (>95%) classification or an advanced characterization using this system. It is necessary to have a larger database fore more accurate system learning.
The history of female genital tract malformation classifications and proposal of an updated system.
Acién, Pedro; Acién, Maribel I
2011-01-01
A correct classification of malformations of the female genital tract is essential to prevent unnecessary and inadequate surgical operations and to compare reproductive results. An ideal classification system should be based on aetiopathogenesis and should suggest the appropriate therapeutic strategy. We conducted a systematic review of relevant articles found in PubMed, Scopus, Scirus and ISI webknowledge, and analysis of historical collections of 'female genital malformations' and 'classifications'. Of 124 full-text articles assessed for eligibility, 64 were included because they contained original general, partial or modified classifications. All the existing classifications were analysed and grouped. The unification of terms and concepts was also analysed. Traditionally, malformations of the female genital tract have been catalogued and classified as Müllerian malformations due to agenesis, lack of fusion, the absence of resorption and lack of posterior development of the Müllerian ducts. The American Fertility Society classification of the late 1980s included seven basic groups of malformations also considering the Müllerian development and the relationship of the malformations to fertility. Other classifications are based on different aspects: functional, defects in vertical fusion, embryological or anatomical (Vagina, Cervix, Uterus, Adnex and Associated Malformation: VCUAM classification). However, an embryological-clinical classification system seems to be the most appropriate. Accepting the need for a new classification system of genitourinary malformations that considers the experience gained from the application of the current classification systems, the aetiopathogenesis and that also suggests the appropriate treatment, we proposed an update of our embryological-clinical classification as a new system with six groups of female genitourinary anomalies.
Safety assessment for In-service Pressure Bending Pipe Containing Incomplete Penetration Defects
NASA Astrophysics Data System (ADS)
Wang, M.; Tang, P.; Xia, J. F.; Ling, Z. W.; Cai, G. Y.
2017-12-01
Incomplete penetration defect is a common defect in the welded joint of pressure pipes. While the safety classification of pressure pipe containing incomplete penetration defects, according to periodical inspection regulations in present, is more conservative. For reducing the repair of incomplete penetration defect, a scientific and applicable safety assessment method for pressure pipe is needed. In this paper, the stress analysis model of the pipe system was established for the in-service pressure bending pipe containing incomplete penetration defects. The local finite element model was set up to analyze the stress distribution of defect location and the stress linearization. And then, the applicability of two assessment methods, simplified assessment and U factor assessment method, to the assessment of incomplete penetration defects located at pressure bending pipe were analyzed. The results can provide some technical supports for the safety assessment of complex pipelines in the future.
Reconstruction of the midface and maxilla.
Dalgorf, Dustin; Higgins, Kevin
2008-08-01
To review the current classification systems and reconstructive options available for restoration of maxillectomy defects. Defects involving the midface can have a great functional and aesthetic impact on the patient. Adequate restoration of the complex three-dimensional maxillary structure is required to replace form and function of the native tissue. An in-depth discussion of appropriate recipient vessel selection and reconstructive options are included in this article. The superficial temporal vessel system is presented as a reliable anastomosis site for restoration of midfacial defects. In addition, the complications of vein grafting, arteriovenous fistula loops and alternative recipient vessels sites are addressed to manage the challenge of the vessel-depleted neck. The current indications, advantages and disadvantages of local, regional and free-flap reconstructive options available for maxillectomy defects are highlighted in order to aid the surgeon in appropriate flap selection. A myriad of reconstructive options are available to restore maxillectomy defects. The surgeon must consider each defect and the needs of the individual patient when choosing the best suited reconstructive technique.
7 CFR 51.652 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Classification of defects. 51.652 Section 51.652 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.652 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Classification of defects. 51.652 Section 51.652 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.1877 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Classification of defects. 51.1877 Section 51.1877 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.652 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Classification of defects. 51.652 Section 51.652 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.713 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Classification of defects. 51.713 Section 51.713 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.713 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Classification of defects. 51.713 Section 51.713 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.652 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Classification of defects. 51.652 Section 51.652 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.713 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Classification of defects. 51.713 Section 51.713 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.713 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Classification of defects. 51.713 Section 51.713 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.1877 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Classification of defects. 51.1877 Section 51.1877 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.1877 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Classification of defects. 51.1877 Section 51.1877 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.713 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Classification of defects. 51.713 Section 51.713 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.1877 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Classification of defects. 51.1877 Section 51.1877 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
7 CFR 51.652 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Classification of defects. 51.652 Section 51.652 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...
Evaluation of articulation simulation system using artificial maxillectomy models.
Elbashti, M E; Hattori, M; Sumita, Y I; Taniguchi, H
2015-09-01
Acoustic evaluation is valuable for guiding the treatment of maxillofacial defects and determining the effectiveness of rehabilitation with an obturator prosthesis. Model simulations are important in terms of pre-surgical planning and pre- and post-operative speech function. This study aimed to evaluate the acoustic characteristics of voice generated by an articulation simulation system using a vocal tract model with or without artificial maxillectomy defects. More specifically, we aimed to establish a speech simulation system for maxillectomy defect models that both surgeons and maxillofacial prosthodontists can use in guiding treatment planning. Artificially simulated maxillectomy defects were prepared according to Aramany's classification (Classes I-VI) in a three-dimensional vocal tract plaster model of a subject uttering the vowel /a/. Formant and nasalance acoustic data were analysed using Computerized Speech Lab and the Nasometer, respectively. Formants and nasalance of simulated /a/ sounds were successfully detected and analysed. Values of Formants 1 and 2 for the non-defect model were 675.43 and 976.64 Hz, respectively. Median values of Formants 1 and 2 for the defect models were 634.36 and 1026.84 Hz, respectively. Nasalance was 11% in the non-defect model, whereas median nasalance was 28% in the defect models. The results suggest that an articulation simulation system can be used to help surgeons and maxillofacial prosthodontists to plan post-surgical defects that will be facilitate maxillofacial rehabilitation. © 2015 John Wiley & Sons Ltd.
Automated stent defect detection and classification with a high numerical aperture optical system
NASA Astrophysics Data System (ADS)
Bermudez, Carlos; Laguarta, Ferran; Cadevall, Cristina; Matilla, Aitor; Ibañez, Sergi; Artigas, Roger
2017-06-01
Stent quality control is a highly critical process. Cardiovascular stents have to be inspected 100% so as no defective stent is implanted in a human body. However, this visual control is currently performed manually and every stent could need tenths of minutes to be inspected. In this paper, a novel optical inspection system is presented. By the combination of a high numerical aperture (NA) optical system, a rotational stage and a line-scan camera, unrolled sections of the outer and inner surfaces of the stent are obtained and image-processed at high speed. Defects appearing in those surfaces and also in the edges are extremely contrasted due to the shadowing effect of the high NA illumination and acquisition approach. Therefore by means of morphological operations and a sensitivity parameter, defects are detected. Based on a trained defect library, a binary classifier sorts each kind of defect through a set of scoring vectors, providing the quality operator with all the required information to finally take a decision. We expect this new approach to make defect detection completely objective and to dramatically reduce the time and cost of stent quality control stage.
Little string origin of surface defects
NASA Astrophysics Data System (ADS)
Haouzi, Nathan; Schmid, Christian
2017-05-01
We derive a large class of codimension-two defects of 4d \\mathcal{N}=4 Super Yang-Mills (SYM) theory from the (2, 0) little string. The origin of the little string is type IIB theory compactified on an ADE singularity. The defects are D-branes wrapping the 2-cycles of the singularity. We use this construction to make contact with the description of SYM defects due to Gukov and Witten [1]. Furthermore, we provide a geometric perspective on the nilpotent orbit classification of codimension-two defects, and the connection to ADE-type Toda CFT. The only data needed to specify the defects is a set of weights of the algebra obeying certain constraints, which we give explicitly. We highlight the differences between the defect classification in the little string theory and its (2 , 0) CFT limit.
Classification and printability of EUV mask defects from SEM images
NASA Astrophysics Data System (ADS)
Cho, Wonil; Price, Daniel; Morgan, Paul A.; Rost, Daniel; Satake, Masaki; Tolani, Vikram L.
2017-10-01
Classification and Printability of EUV Mask Defects from SEM images EUV lithography is starting to show more promise for patterning some critical layers at 5nm technology node and beyond. However, there still are many key technical obstacles to overcome before bringing EUV Lithography into high volume manufacturing (HVM). One of the greatest obstacles is manufacturing defect-free masks. For pattern defect inspections in the mask-shop, cutting-edge 193nm optical inspection tools have been used so far due to lacking any e-beam mask inspection (EBMI) or EUV actinic pattern inspection (API) tools. The main issue with current 193nm inspection tools is the limited resolution for mask dimensions targeted for EUV patterning. The theoretical resolution limit for 193nm mask inspection tools is about 60nm HP on masks, which means that main feature sizes on EUV masks will be well beyond the practical resolution of 193nm inspection tools. Nevertheless, 193nm inspection tools with various illumination conditions that maximize defect sensitivity and/or main-pattern modulation are being explored for initial EUV defect detection. Due to the generally low signal-to-noise in the 193nm inspection imaging at EUV patterning dimensions, these inspections often result in hundreds and thousands of defects which then need to be accurately reviewed and dispositioned. Manually reviewing each defect is difficult due to poor resolution. In addition, the lack of a reliable aerial dispositioning system makes it very challenging to disposition for printability. In this paper, we present the use of SEM images of EUV masks for higher resolution review and disposition of defects. In this approach, most of the defects detected by the 193nm inspection tools are first imaged on a mask SEM tool. These images together with the corresponding post-OPC design clips are provided to KLA-Tencor's Reticle Decision Center (RDC) platform which provides ADC (Automated Defect Classification) and S2A (SEM-to-Aerial printability) analysis of every defect. First, a defect-free or reference mask SEM is rendered from the post-OPC design, and the defective signature is detected from the defect-reference difference image. These signatures help assess the true nature of the defect as evident in e-beam imaging; for example, excess or missing absorber, line-edge roughness, contamination, etc. Next, defect and reference contours are extracted from the grayscale SEM images and fed into the simulation engine with an EUV scanner model to generate corresponding EUV defect and reference aerial images. These are then analyzed for printability and dispositioned using an Aerial Image Analyzer (AIA) application to automatically measure and determine the amount of CD errors. Thus by integrating EUV ADC and S2A applications together, every defect detection is characterized for its type and printability which is essential for not only determining which defects to repair, but also in monitoring the performance of EUV mask process tools. The accuracy of the S2A print modeling has been verified with other commercially-available simulators, and will also be verified with actual wafer print results. With EUV lithography progressing towards volume manufacturing at 5nm technology, and the likelihood of EBMI inspectors approaching the horizon, the EUV ADC-S2A system will continue serving an essential role of dispositioning defects off e-beam imaging.
Saludes-Rodil, Sergio; Baeyens, Enrique; Rodríguez-Juan, Carlos P
2015-04-29
An unsupervised approach to classify surface defects in wire rod manufacturing is developed in this paper. The defects are extracted from an eddy current signal and classified using a clustering technique that uses the dynamic time warping distance as the dissimilarity measure. The new approach has been successfully tested using industrial data. It is shown that it outperforms other classification alternatives, such as the modified Fourier descriptors.
Deep sub-wavelength metrology for advanced defect classification
NASA Astrophysics Data System (ADS)
van der Walle, P.; Kramer, E.; van der Donck, J. C. J.; Mulckhuyse, W.; Nijsten, L.; Bernal Arango, F. A.; de Jong, A.; van Zeijl, E.; Spruit, H. E. T.; van den Berg, J. H.; Nanda, G.; van Langen-Suurling, A. K.; Alkemade, P. F. A.; Pereira, S. F.; Maas, D. J.
2017-06-01
Particle defects are important contributors to yield loss in semi-conductor manufacturing. Particles need to be detected and characterized in order to determine and eliminate their root cause. We have conceived a process flow for advanced defect classification (ADC) that distinguishes three consecutive steps; detection, review and classification. For defect detection, TNO has developed the Rapid Nano (RN3) particle scanner, which illuminates the sample from nine azimuth angles. The RN3 is capable of detecting 42 nm Latex Sphere Equivalent (LSE) particles on XXX-flat Silicon wafers. For each sample, the lower detection limit (LDL) can be verified by an analysis of the speckle signal, which originates from the surface roughness of the substrate. In detection-mode (RN3.1), the signal from all illumination angles is added. In review-mode (RN3.9), the signals from all nine arms are recorded individually and analyzed in order to retrieve additional information on the shape and size of deep sub-wavelength defects. This paper presents experimental and modelling results on the extraction of shape information from the RN3.9 multi-azimuth signal such as aspect ratio, skewness, and orientation of test defects. Both modeling and experimental work confirm that the RN3.9 signal contains detailed defect shape information. After review by RN3.9, defects are coarsely classified, yielding a purified Defect-of-Interest (DoI) list for further analysis on slower metrology tools, such as SEM, AFM or HIM, that provide more detailed review data and further classification. Purifying the DoI list via optical metrology with RN3.9 will make inspection time on slower review tools more efficient.
Pang, Kun-Jing; Meng, Hong; Hu, Sheng-Shou; Wang, Hao; Hsi, David; Hua, Zhong-Dong; Pan, Xiang-Bin; Li, Shou-Jun
2017-08-01
Selecting an appropriate surgical approach for double-outlet right ventricle (DORV), a complex congenital cardiac malformation with many anatomic variations, is difficult. Therefore, we determined the feasibility of using an echocardiographic classification system, which describes the anatomic variations in more precise terms than the current system does, to determine whether it could help direct surgical plans. Our system includes 8 DORV subtypes, categorized according to 3 factors: the relative positions of the great arteries (normal or abnormal), the relationship between the great arteries and the ventricular septal defect (committed or noncommitted), and the presence or absence of right ventricular outflow tract obstruction (RVOTO). Surgical approaches in 407 patients were based on their DORV subtype, as determined by echocardiography. We found that the optimal surgical management of patients classified as normal/committed/no RVOTO, normal/committed/RVOTO, and abnormal/committed/no RVOTO was, respectively, like that for patients with large ventricular septal defects, tetralogy of Fallot, and transposition of the great arteries without RVOTO. Patients with abnormal/committed/RVOTO anatomy and those with abnormal/noncommitted/RVOTO anatomy underwent intraventricular repair and double-root translocation. For patients with other types of DORV, choosing the appropriate surgical approach and biventricular repair techniques was more complex. We think that our classification system accurately groups DORV patients and enables surgeons to select the best approach for each patient's cardiac anatomy.
Ultrasonic sensor based defect detection and characterisation of ceramics.
Kesharaju, Manasa; Nagarajah, Romesh; Zhang, Tonzhua; Crouch, Ian
2014-01-01
Ceramic tiles, used in body armour systems, are currently inspected visually offline using an X-ray technique that is both time consuming and very expensive. The aim of this research is to develop a methodology to detect, locate and classify various manufacturing defects in Reaction Sintered Silicon Carbide (RSSC) ceramic tiles, using an ultrasonic sensing technique. Defects such as free silicon, un-sintered silicon carbide material and conventional porosity are often difficult to detect using conventional X-radiography. An alternative inspection system was developed to detect defects in ceramic components using an Artificial Neural Network (ANN) based signal processing technique. The inspection methodology proposed focuses on pre-processing of signals, de-noising, wavelet decomposition, feature extraction and post-processing of the signals for classification purposes. This research contributes to developing an on-line inspection system that would be far more cost effective than present methods and, moreover, assist manufacturers in checking the location of high density areas, defects and enable real time quality control, including the implementation of accept/reject criteria. Copyright © 2013 Elsevier B.V. All rights reserved.
MR-defecography in obstructed defecation syndrome (ODS): technique, diagnostic criteria and grading.
Piloni, V; Tosi, P; Vernelli, M
2013-10-01
The aim of this study was to evaluate the use of a magnetic resonance (MR)-based classification system of obstructive defecation syndrome (ODS) to guide physicians in patient management. The medical records and imaging series of 105 consecutive patients (90 female, 15 male, aged 21-78 years, mean age 46.1 ± 5.1 years) referred to our center between April 2011 and January 2012 for symptoms of ODS were retrospectively examined. After history taking and a complete clinical examination, patients underwent MR imaging according to a standard protocol using a 0.35 T permanent field, horizontally oriented open-configuration magnet. Static and dynamic MR-defecography was performed using recognized parameters and well-established diagnostic criteria. Sixty-seven out of 105 (64 %) patients found the prone position more comfortable for the evacuation of rectal contrast while 10/105 (9.5 %) were unable to empty their rectum despite repeated attempts. Increased hiatus size, anterior rectocele and focal or extensive defects of the levator ani muscle were the most frequent abnormalities (67.6, 60.0 and 51.4 %, respectively). An MR-based classification was developed based on the combinations of abnormalities found: Grade 1 = functional abnormality, including paradoxical contraction of the puborectalis muscle, without anatomical defect affecting the musculo-fascial structures; Grade 2 = functional defect associated with a minor anatomical defect such as rectocele ≤ 2 cm in size and/or first-degree intussusception; Grade 3 = severe defects confined to the posterior anatomical compartment, including >2 cm rectocele, second- or higher-degree intussusception, full-thickness external rectal prolapse, poor mesorectal posterior fixation, rectal descent >5 cm, levator ani muscle rupture, ballooning of the levator hiatus and focal detachment of the endopelvic fascia; Grade 4 = combined defects of two or three pelvic floor compartments, including cystocele, hysterocele, enlarged urogenital hiatus, fascial tears enterocele or peritoneocele; Grade 5 = changes after failed surgical repair abscess/sinus tracts, rectal pockets, anastomotic strictures, small uncompliant rectum, kinking and/or lateral shift of supra-anastomotic portion and pudendal nerve entrapment. According to our classification, Grades 1 and 2 may be amenable to conservative therapy; Grade 3 may require surgical intervention by a coloproctologist; Grade 4 would need a combined urogynecological and coloproctological approach; and Grade 5 may require an even more complex multidisciplinary approach. Validation studies are needed to assess whether this MR-based classification system leads to a better management of patients with ODS.
High-speed atomic force microscopy and peak force tapping control
NASA Astrophysics Data System (ADS)
Hu, Shuiqing; Mininni, Lars; Hu, Yan; Erina, Natalia; Kindt, Johannes; Su, Chanmin
2012-03-01
ITRS Roadmap requires defect size measurement below 10 nanometers and challenging classifications for both blank and patterned wafers and masks. Atomic force microscope (AFM) is capable of providing metrology measurement in 3D at sub-nanometer accuracy but has long suffered from drawbacks in throughput and limitation of slow topography imaging without chemical information. This presentation focus on two disruptive technology developments, namely high speed AFM and quantitative nanomechanical mapping, which enables high throughput measurement with capability of identifying components through concurrent physical property imaging. The high speed AFM technology has allowed the imaging speed increase by 10-100 times without loss of the data quality. Such improvement enables the speed of defect review on a wafer to increase from a few defects per hour to nearly 100 defects an hour, approaching the requirements of ITRS Roadmap. Another technology development, Peak Force Tapping, substantially simplified the close loop system response, leading to self-optimization of most challenging samples groups to generate expert quality data. More importantly, AFM also simultaneously provides a series of mechanical property maps with a nanometer spatial resolution during defect review. These nanomechanical maps (including elastic modulus, hardness, and surface adhesion) provide complementary information for elemental analysis, differentiate defect materials by their physical properties, and assist defect classification beyond topographic measurements. This paper will explain the key enabling technologies, namely high speed tip-scanning AFM using innovative flexure design and control algorithm. Another critical element is AFM control using Peak Force Tapping, in which the instantaneous tip-sample interaction force is measured and used to derive a full suite of physical properties at each imaging pixel. We will provide examples of defect review data on different wafers and media disks. The similar AFM-based defect review capacity was also applied to EUV masks.
Reshchikov, M. A.; McNamara, J. D.; Toporkov, M.; Avrutin, V.; Morkoç, H.; Usikov, A.; Helava, H.; Makarov, Yu.
2016-01-01
Point defects in high-purity GaN layers grown by hydride vapor phase epitaxy are studied by steady-state and time-resolved photoluminescence (PL). The electron-capture coefficients for defects responsible for the dominant defect-related PL bands in this material are found. The capture coefficients for all the defects, except for the green luminescence (GL1) band, are independent of temperature. The electron-capture coefficient for the GL1 band significantly changes with temperature because the GL1 band is caused by an internal transition in the related defect, involving an excited state acting as a giant trap for electrons. By using the determined electron-capture coefficients, the concentration of free electrons can be found at different temperatures by a contactless method. A new classification system is suggested for defect-related PL bands in undoped GaN. PMID:27901025
On the relationship between topological and geometric defects.
Griffin, Sinéad M; Spaldin, Nicola A
2017-08-31
The study of topology in solids is undergoing a renaissance following renewed interest in the properties of ferroic domain walls as well as recent discoveries regarding skyrmionic lattices. Each of these systems possess a property that is 'protected' in a symmetry sense, and is defined rigorously using a branch of mathematics known as topology. In this article we review the formal definition of topological defects as they are classified in terms of homotopy theory, and discuss the precise symmetry-breaking conditions that lead to their formation. We distinguish topological defects from defects that arise from the details of the stacking or structure of the material but are not protected by symmetry, and we propose the term 'geometric defects' to describe the latter. We provide simple material examples of both topological and geometric defect types, and discuss the implications of the classification on the resulting material properties.
Classification of symmetry-protected phases for interacting fermions in two dimensions
NASA Astrophysics Data System (ADS)
Cheng, Meng; Bi, Zhen; You, Yi-Zhuang; Gu, Zheng-Cheng
2018-05-01
Recently, it has been established that two-dimensional bosonic symmetry-protected topological (SPT) phases with on-site unitary symmetry G can be completely classified by the group cohomology H3( G ,U (1 ) ) . Later, group supercohomology was proposed as a partial classification for SPT phases of interacting fermions. In this work, we revisit this problem based on the algebraic theory of symmetry and defects in two-dimensional topological phases. We reproduce the partial classifications given by group supercohomology, and we also show that with an additional H1(G ,Z2) structure, a complete classification of SPT phases for two-dimensional interacting fermion systems with a total symmetry group G ×Z2f is obtained. We also discuss the classification of interacting fermionic SPT phases protected by time-reversal symmetry.
A 3D Laser Profiling System for Rail Surface Defect Detection
Li, Qingquan; Mao, Qingzhou; Zou, Qin
2017-01-01
Rail surface defects such as the abrasion, scratch and peeling often cause damages to the train wheels and rail bearings. An efficient and accurate detection of rail defects is of vital importance for the safety of railway transportation. In the past few decades, automatic rail defect detection has been studied; however, most developed methods use optic-imaging techniques to collect the rail surface data and are still suffering from a high false recognition rate. In this paper, a novel 3D laser profiling system (3D-LPS) is proposed, which integrates a laser scanner, odometer, inertial measurement unit (IMU) and global position system (GPS) to capture the rail surface profile data. For automatic defect detection, first, the deviation between the measured profile and a standard rail model profile is computed for each laser-imaging profile, and the points with large deviations are marked as candidate defect points. Specifically, an adaptive iterative closest point (AICP) algorithm is proposed to register the point sets of the measured profile with the standard rail model profile, and the registration precision is improved to the sub-millimeter level. Second, all of the measured profiles are combined together to form the rail surface through a high-precision positioning process with the IMU, odometer and GPS data. Third, the candidate defect points are merged into candidate defect regions using the K-means clustering. At last, the candidate defect regions are classified by a decision tree classifier. Experimental results demonstrate the effectiveness of the proposed laser-profiling system in rail surface defect detection and classification. PMID:28777323
Ensemble of classifiers for confidence-rated classification of NDE signal
NASA Astrophysics Data System (ADS)
Banerjee, Portia; Safdarnejad, Seyed; Udpa, Lalita; Udpa, Satish
2016-02-01
Ensemble of classifiers in general, aims to improve classification accuracy by combining results from multiple weak hypotheses into a single strong classifier through weighted majority voting. Improved versions of ensemble of classifiers generate self-rated confidence scores which estimate the reliability of each of its prediction and boost the classifier using these confidence-rated predictions. However, such a confidence metric is based only on the rate of correct classification. In existing works, although ensemble of classifiers has been widely used in computational intelligence, the effect of all factors of unreliability on the confidence of classification is highly overlooked. With relevance to NDE, classification results are affected by inherent ambiguity of classifica-tion, non-discriminative features, inadequate training samples and noise due to measurement. In this paper, we extend the existing ensemble classification by maximizing confidence of every classification decision in addition to minimizing the classification error. Initial results of the approach on data from eddy current inspection show improvement in classification performance of defect and non-defect indications.
Maugans, Todd; Sheridan, Rachel M; Adams, Denise; Gupta, Anita
2011-07-01
Lumbosacral cutaneous vascular anomalies associated with neural tube defects are frequently described in the literature as "hemangiomas." The classification system for pediatric vascular anomalies developed by the International Society for the Study of Vascular Anomalies provides a framework to accurately diagnose these lesions. To apply this classification to vascular cutaneous anomalies overlying myelodysplasias. A retrospective analysis of patients with neural tube defects and lumbosacral cutaneous vascular lesions was performed. All eligible patients had detailed histopathologic analysis of skin and spinal cord/placode lesions. Clinical and radiologic features were analyzed. Conventional histology and GLUT-1 immunostaining were performed to differentiate infantile capillary hemangiomas from capillary vascular malformations. Ten cases with cutaneous lesions associated with neural tube defects were reviewed. Five lesions were diagnosed as infantile capillary hemangiomas based upon histology and positive GLUT-1 endothelial reactivity. These lesions had a strong association with dermal sinus tracts. No reoperations were required for residual intraspinal vascular lesions, and overlying cutaneous vascular anomalies involuted with time. The remaining 5 lesions were diagnosed as capillary malformations. These occurred with both open and closed neural tube defects, did not involute, and demonstrated enlargement and darkening due to vascular congestion. The International Society for the Study of Vascular Anomalies scheme should be used to describe the cutaneous vascular lesions associated with neural tube defects: infantile capillary hemangiomas and capillary malformations. We advocate that these lesions be described as "vascular anomalies" or "stains" pending accurate diagnosis by clinical, histological, and immunohistochemical evaluations.
The SCHEIE Visual Field Grading System
Sankar, Prithvi S.; O’Keefe, Laura; Choi, Daniel; Salowe, Rebecca; Miller-Ellis, Eydie; Lehman, Amanda; Addis, Victoria; Ramakrishnan, Meera; Natesh, Vikas; Whitehead, Gideon; Khachatryan, Naira; O’Brien, Joan
2017-01-01
Objective No method of grading visual field (VF) defects has been widely accepted throughout the glaucoma community. The SCHEIE (Systematic Classification of Humphrey visual fields-Easy Interpretation and Evaluation) grading system for glaucomatous visual fields was created to convey qualitative and quantitative information regarding visual field defects in an objective, reproducible, and easily applicable manner for research purposes. Methods The SCHEIE grading system is composed of a qualitative and quantitative score. The qualitative score consists of designation in one or more of the following categories: normal, central scotoma, paracentral scotoma, paracentral crescent, temporal quadrant, nasal quadrant, peripheral arcuate defect, expansive arcuate, or altitudinal defect. The quantitative component incorporates the Humphrey visual field index (VFI), location of visual defects for superior and inferior hemifields, and blind spot involvement. Accuracy and speed at grading using the qualitative and quantitative components was calculated for non-physician graders. Results Graders had a median accuracy of 96.67% for their qualitative scores and a median accuracy of 98.75% for their quantitative scores. Graders took a mean of 56 seconds per visual field to assign a qualitative score and 20 seconds per visual field to assign a quantitative score. Conclusion The SCHEIE grading system is a reproducible tool that combines qualitative and quantitative measurements to grade glaucomatous visual field defects. The system aims to standardize clinical staging and to make specific visual field defects more easily identifiable. Specific patterns of visual field loss may also be associated with genetic variants in future genetic analysis. PMID:28932621
Feature extraction for ultrasonic sensor based defect detection in ceramic components
NASA Astrophysics Data System (ADS)
Kesharaju, Manasa; Nagarajah, Romesh
2014-02-01
High density silicon carbide materials are commonly used as the ceramic element of hard armour inserts used in traditional body armour systems to reduce their weight, while providing improved hardness, strength and elastic response to stress. Currently, armour ceramic tiles are inspected visually offline using an X-ray technique that is time consuming and very expensive. In addition, from X-rays multiple defects are also misinterpreted as single defects. Therefore, to address these problems the ultrasonic non-destructive approach is being investigated. Ultrasound based inspection would be far more cost effective and reliable as the methodology is applicable for on-line quality control including implementation of accept/reject criteria. This paper describes a recently developed methodology to detect, locate and classify various manufacturing defects in ceramic tiles using sub band coding of ultrasonic test signals. The wavelet transform is applied to the ultrasonic signal and wavelet coefficients in the different frequency bands are extracted and used as input features to an artificial neural network (ANN) for purposes of signal classification. Two different classifiers, using artificial neural networks (supervised) and clustering (un-supervised) are supplied with features selected using Principal Component Analysis(PCA) and their classification performance compared. This investigation establishes experimentally that Principal Component Analysis(PCA) can be effectively used as a feature selection method that provides superior results for classifying various defects in the context of ultrasonic inspection in comparison with the X-ray technique.
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.1175 Classification of defects. Table I Factor Injury Damage Serious damage Very serious... mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of... 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.784 Classification of defects. Table I Factor Injury Damage Serious damage Very serious.../4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or the equivalent of...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.784 Classification of defects. Table I Factor Injury Damage Serious damage Very serious.../4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or the equivalent of...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.1837 Classification of defects. Table I Factor Damage Serious damage Very serious damage... segments more than 1/8 inch (3.2 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or...
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.1175 Classification of defects. Table I Factor Injury Damage Serious damage Very serious... mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of... 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.1837 Classification of defects. Table I Factor Damage Serious damage Very serious damage... segments more than 1/8 inch (3.2 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or...
Maxillary reconstruction: Current concepts and controversies
Iyer, Subramania; Thankappan, Krishnakumar
2014-01-01
Maxillary reconstruction is still an evolving art when compared to the reconstruction of the mandible. The defects of maxilla apart from affecting the functions of the speech, swallowing and mastication also cause cosmetic disfigurement. Rehabilitation of the form and function in patients with maxillary defects is either by using an obturator prosthesis or by a surgical reconstruction. Literature is abundant with a variety of reconstructive methods. The classification systems are also varied, with no universal acceptance of any one of them. The oncologic safety of these procedures is still debated, and conclusive evidence in this regard has not emerged yet. Management of the orbit is also not yet addressed properly. Tissue engineering, that has been hyped to be one of the possible solutions for this vexing reconstructive problem, has not come out with reliable and reproducible results so far. This review article discusses the rationale and oncological safety of the reconstructing the maxillary defects, critically analyzes the classification systems, offers the different reconstructive methods and touches upon the controversies in this subject. The management of the retained and exenterated orbit associated with maxillectomy is reviewed. The surgical morbidity, complications and the recent advances in this field are also looked into. An algorithm, based on our experience, is presented. PMID:24987199
Classification of product inspection items using nonlinear features
NASA Astrophysics Data System (ADS)
Talukder, Ashit; Casasent, David P.; Lee, H.-W.
1998-03-01
Automated processing and classification of real-time x-ray images of randomly oriented touching pistachio nuts is discussed. The ultimate objective is the development of a system for automated non-invasive detection of defective product items on a conveyor belt. This approach involves two main steps: preprocessing and classification. Preprocessing locates individual items and segments ones that touch using a modified watershed algorithm. The second stage involves extraction of features that allow discrimination between damaged and clean items (pistachio nuts). This feature extraction and classification stage is the new aspect of this paper. We use a new nonlinear feature extraction scheme called the maximum representation and discriminating feature (MRDF) extraction method to compute nonlinear features that are used as inputs to a classifier. The MRDF is shown to provide better classification and a better ROC (receiver operating characteristic) curve than other methods.
A Novel Machine Vision System for the Inspection of Micro-Spray Nozzle
Huang, Kuo-Yi; Ye, Yu-Ting
2015-01-01
In this study, we present an application of neural network and image processing techniques for detecting the defects of an internal micro-spray nozzle. The defect regions were segmented by Canny edge detection, a randomized algorithm for detecting circles and a circle inspection (CI) algorithm. The gray level co-occurrence matrix (GLCM) was further used to evaluate the texture features of the segmented region. These texture features (contrast, entropy, energy), color features (mean and variance of gray level) and geometric features (distance variance, mean diameter and diameter ratio) were used in the classification procedures. A back-propagation neural network classifier was employed to detect the defects of micro-spray nozzles. The methodology presented herein effectively works for detecting micro-spray nozzle defects to an accuracy of 90.71%. PMID:26131678
A Novel Machine Vision System for the Inspection of Micro-Spray Nozzle.
Huang, Kuo-Yi; Ye, Yu-Ting
2015-06-29
In this study, we present an application of neural network and image processing techniques for detecting the defects of an internal micro-spray nozzle. The defect regions were segmented by Canny edge detection, a randomized algorithm for detecting circles and a circle inspection (CI) algorithm. The gray level co-occurrence matrix (GLCM) was further used to evaluate the texture features of the segmented region. These texture features (contrast, entropy, energy), color features (mean and variance of gray level) and geometric features (distance variance, mean diameter and diameter ratio) were used in the classification procedures. A back-propagation neural network classifier was employed to detect the defects of micro-spray nozzles. The methodology presented herein effectively works for detecting micro-spray nozzle defects to an accuracy of 90.71%.
Marx, Ítala; Rodrigues, Nuno; Dias, Luís G; Veloso, Ana C A; Pereira, José A; Drunkler, Deisy A; Peres, António M
2017-01-01
Table olives are highly appreciated and consumed worldwide. Different aspects are used for trade category classification being the sensory assessment of negative defects present in the olives and brines one of the most important. The trade category quality classification must follow the International Olive Council directives, requiring the organoleptic assessment of defects by a trained sensory panel. However, the training process is a hard, complex and sometimes subjective task, being the low number of samples that can be evaluated per day a major drawback considering the real needs of the olive industry. In this context, the development of electronic tongues as taste sensors for defects' sensory evaluation is of utmost relevance. So, an electronic tongue was used for table olives classification according to the presence and intensity of negative defects. Linear discrimination models were established based on sub-sets of sensor signals selected by a simulated annealing algorithm. The predictive potential of the novel approach was first demonstrated for standard solutions of chemical compounds that mimic butyric, putrid and zapateria defects (≥93% for cross-validation procedures). Then its applicability was verified; using reference table olives/brine solutions samples identified with a single intense negative attribute, namely butyric, musty, putrid, zapateria or winey-vinegary defects (≥93% cross-validation procedures). Finally, the E-tongue coupled with the same chemometric approach was applied to classify table olive samples according to the trade commercial categories (extra, 1 st choice, 2 nd choice and unsuitable for consumption) and an additional quality category (extra free of defects), established based on sensory analysis data. Despite the heterogeneity of the samples studied and number of different sensory defects perceived, the predictive linear discriminant model established showed sensitivities greater than 86%. So, the overall performance achieved showed that the electrochemical device could be used as a taste sensor for table olives organoleptic trade successful classification, allowing a preliminary quality assessment, which could facilitate, in the future, the complex task of sensory panelists. Copyright © 2016 Elsevier B.V. All rights reserved.
Study of amended reports to evaluate and improve surgical pathology processes.
Meier, Frederick A; Varney, Ruan C; Zarbo, Richard J
2011-09-01
: Amended surgical pathology reports record defects in the process of transforming tissue specimens into diagnostic information. : Systematic study of amended reports tests 2 hypotheses: (a) that tracking amendment frequencies and the distribution of amendment types reveals relevant aspects of quality in surgical pathology's daily transformation of specimens into diagnoses and (b) that such tracking measures the effect, or lack of effect, of efforts to improve surgical pathology processes. : We applied a binary definition of altered reports as either amendments or addenda and a taxonomy of defects that caused amendments as misidentifications, specimen defects, misinterpretations, and report defects. During the introduction of a LEAN process improvement approach-the Henry Ford Productions System-we followed trends in amendment rates and defect fractions to (a) evaluate specific interventions, (b) sort case-by-case root causes of misidentifications, specimen defects, and misinterpretations, and (c) audit the ongoing accuracy of the classification of changed reports. LEAN is the management and production system of the Toyota Motor Corporation that promotes continuous improvement; it considers wasted resources expended for purposes other than creating value for end customers and targets such expenditures for elimination. : Introduction of real-time editing of amendments saw annual amendment rates increase from 4.8/1000 to 10.1/1000 and then decrease in an incremental manner to 5.6/1000 as Henry Ford Productions System-specific interventions were introduced. Before introduction of HFPS interventions, about a fifth of the amendments were due to misidentifications, a 10th were due to specimen defects, a quarter due to misinterpretation, and almost half were due to report defects. During the period of the initial application of HFPS, the fraction of amendments due to misidentifications decreased as those due to report defects increased, in a statistically linked manner. As HFPS interventions took hold, misidentifications fell from 16% to 9%, specimen defect rates remained variable, ranging between 2% and 11%, and misinterpretations fell from 18% to 3%. Reciprocally, report defects rose from 64% to 83% of all amendment-causing defects. A case-by-case study of misidentifications, specimen defects, and misinterpretations found that (a) intervention at the specimen collection level had disappointingly little effect on patient misidentifications; (b) standardization of specimen accession and gross examination reduced only specimen defects surrounding ancillary testing; but (c) a double review of breast and prostate cases was associated with drastically reduced misinterpretation defects. Finally, audit of both amendments and addenda demonstrated that 10% of the so-called addenda actually qualified as amendments. : Monitored by the consistent taxonomy, rates of amended reports first rose, then fell. Examining specific defect categories provided information for evaluating specific LEAN interventions. Tracking the downward trend of amendment rates seemed to document the overall success of surgical pathology quality improvement efforts. Process improvements modestly decreased fractions of misidentifications and markedly decreased misinterpretation fractions. Classification integrity requires real time, independent editing of both amendments (changed reports) and addenda (addition to reports).
Cheng, Shaobo; Li, Jun; Han, Myung-Geun; ...
2017-04-05
Here, we report structural transformation of sixfold vortex domains into two-, four-, and eightfold vortices via a different type of topological defect in hexagonal manganites. Combining high-resolution electron microscopy and Landau-theory-based numerical simulations, we also investigate the remarkable atomic arrangement and the intertwined relationship between the vortex structures and the topological defects. The roles of their displacement field, formation temperature, and nucleation sites are revealed. All conceivable vortices in the system are topologically classified using homotopy group theory, and their origins are identified.
7 CFR 51.2954 - Tolerances for grade defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... grades as indicated. Terms in quotation marks refer to color classifications illustrated on the color chart. Tolerances for Grade Defects Grade External (shell) defects Internal (kernel) defects Color of... tolerance to reduce the required 70 pct of “light amber” kernels or the required 40 pct of “light” kernels...
7 CFR 51.2954 - Tolerances for grade defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... meet the requirements of the respective grades as indicated. Terms in quotation marks refer to color classifications illustrated on the color chart. Tolerances for Grade Defects Grade External (shell) defects Internal (kernel) defects Color of kernel U.S. No. 1. 10 pct, by count for splits. 5 pct. by count, for...
7 CFR 51.2954 - Tolerances for grade defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... meet the requirements of the respective grades as indicated. Terms in quotation marks refer to color classifications illustrated on the color chart. Tolerances for Grade Defects Grade External (shell) defects Internal (kernel) defects Color of kernel U.S. No. 1. 10 pct, by count for splits. 5 pct. by count, for...
Defects in Amorphous Semiconductors: The Case of Amorphous Indium Gallium Zinc Oxide
NASA Astrophysics Data System (ADS)
de Jamblinne de Meux, A.; Pourtois, G.; Genoe, J.; Heremans, P.
2018-05-01
Based on a rational classification of defects in amorphous materials, we propose a simplified model to describe intrinsic defects and hydrogen impurities in amorphous indium gallium zinc oxide (a -IGZO). The proposed approach consists of organizing defects into two categories: point defects, generating structural anomalies such as metal—metal or oxygen—oxygen bonds, and defects emerging from changes in the material stoichiometry, such as vacancies and interstitial atoms. Based on first-principles simulations, it is argued that the defects originating from the second group always act as perfect donors or perfect acceptors. This classification simplifies and rationalizes the nature of defects in amorphous phases. In a -IGZO, the most important point defects are metal—metal bonds (or small metal clusters) and peroxides (O - O single bonds). Electrons are captured by metal—metal bonds and released by the formation of peroxides. The presence of hydrogen can lead to two additional types of defects: metal-hydrogen defects, acting as acceptors, and oxygen-hydrogen defects, acting as donors. The impact of these defects is linked to different instabilities observed in a -IGZO. Specifically, the diffusion of hydrogen and oxygen is connected to positive- and negative-bias stresses, while negative-bias illumination stress originates from the formation of peroxides.
New feature extraction method for classification of agricultural products from x-ray images
NASA Astrophysics Data System (ADS)
Talukder, Ashit; Casasent, David P.; Lee, Ha-Woon; Keagy, Pamela M.; Schatzki, Thomas F.
1999-01-01
Classification of real-time x-ray images of randomly oriented touching pistachio nuts is discussed. The ultimate objective is the development of a system for automated non- invasive detection of defective product items on a conveyor belt. We discuss the extraction of new features that allow better discrimination between damaged and clean items. This feature extraction and classification stage is the new aspect of this paper; our new maximum representation and discrimination between damaged and clean items. This feature extraction and classification stage is the new aspect of this paper; our new maximum representation and discriminating feature (MRDF) extraction method computes nonlinear features that are used as inputs to a new modified k nearest neighbor classifier. In this work the MRDF is applied to standard features. The MRDF is robust to various probability distributions of the input class and is shown to provide good classification and new ROC data.
Defect inspection and printability study for 14 nm node and beyond photomask
NASA Astrophysics Data System (ADS)
Seki, Kazunori; Yonetani, Masashi; Badger, Karen; Dechene, Dan J.; Akima, Shinji
2016-10-01
Two different mask inspection techniques are developed and compared for 14 nm node and beyond photomasks, High resolution and Litho-based inspection. High resolution inspection is the general inspection method in which a 19x nm wavelength laser is used with the High NA inspection optics. Litho-based inspection is a new inspection technology. This inspection uses the wafer lithography information, and as such, this method has automatic defect classification capability which is based on wafer printability. Both High resolution and Litho-based inspection methods are compared using 14 nm and 7 nm node programmed defect and production design masks. The defect sensitivity and mask inspectability is compared, in addition to comparing the defect classification and throughput. Additionally, the Cost / Infrastructure comparison is analyzed and the impact of each inspection method is discussed.
Intentional defect array wafers: their practical use in semiconductor control and monitoring systems
NASA Astrophysics Data System (ADS)
Emami, Iraj; McIntyre, Michael; Retersdorf, Michael
2003-07-01
In the competitive world of semiconductor manufacturing today, control of the process and manufacturing equipment is paramount to success of the business. Consistent with the need for rapid development of process technology, is a need for development wiht respect to equipment control including defect metrology tools. Historical control methods for defect metrology tools included a raw count of defects detected on a characterized production or test wafer with little or not regard to the attributes of the detected defects. Over time, these characterized wafers degrade with multiple passes on the tools and handling requiring the tool owner to create and characterize new samples periodically. With the complex engineering software analysis systems used today, there is a strong reliance on the accuracy of defect size, location, and classification in order to provide the best value when correlating the in line to sort type of data. Intentional Defect Array (IDA) wafers were designed and manufacturered at International Sematech (ISMT) in Austin, Texas and is a product of collaboration between ISMT member companies and suppliers of advanced defect inspection equipment. These wafers provide the use with known defect types and sizes in predetermined locations across the entire wafer. The wafers are designed to incorporate several desired flows and use critical dimensions consistent with current and future technology nodes. This paper briefly describes the design of the IDA wafer and details many practical applications in the control of advanced defect inspection equipment.
Establishing of National Birth Defects Registry in Thailand.
Pangkanon, Suthipong; Sawasdivorn, Siraporn; Kuptanon, Chulaluck; Chotigeat, Uraiwan; Vandepitte, Warunee
2014-06-01
Deaths attributed to birth defects are a major cause of infant and under-five mortality as well as lifetime disabilities among those who survive. In Thailand, birth defects contribute to 21% of neonatal deaths. There is currently no systematic registry for congenital anomalies in Thailand. Queen Sirikit National Institute of Child Health has initiated a Thailand Birth Defects Registry to capture birth defects among newborn infants. To establish the national birth defects registry in order to determine the burden of birth defects in Thailand. The birth defects data come from four main sources: National Birth Registry Database; National Health Security Office's reimbursement database; Online Birth Defect Registry Database designed to capture new cases that were detected later; and birth defects data from 20 participated hospitals. All data are linked by unique 13-digit national identification number and International Classification of Diseases (ICD)-10 codes. This registry includes 19 common structural birth defects conditions and pilots in 20 hospitals. The registry is hospital-based, hybrid reporting system, including only live births whose information was collected up to 1 year of age. 3,696 infants out of 67,813 live births (8.28% of total live births in Thailand) were diagnosed with congenital anomalies. The prevalence rate of major anomalies was 26.12 per 1,000 live births. The five most common birth defects were congenital heart defects, limb anomalies, cleft lip/cleft palate, Down syndrome, and congenital hydrocephalus respectively. The present study established the Birth Defects Registry by collecting data from four databases in Thailand. Information obtained from this registry and surveillance is essential in the planning for effective intervention programs for birth defects. The authors suggest that this program should be integrated in the existing public health system to ensure sustainability.
Management of A Rare Case of Communicating Internal-External Inflammatory Resorption.
Arora, Suraj; Gill, Gurdeep Singh; Saluja, Priyanka; Setia, Vikas
2015-05-01
The present case describes the successful management of a rare case of communicating internal-external resorption in which both internal and external resorption seem to develop independent of each other. The case report highlights the importance of correct diagnosis and need of revision of classification system of resorptive defects.
Management of A Rare Case of Communicating Internal-External Inflammatory Resorption
Arora, Suraj; Saluja, Priyanka; Setia, Vikas
2015-01-01
The present case describes the successful management of a rare case of communicating internal-external resorption in which both internal and external resorption seem to develop independent of each other. The case report highlights the importance of correct diagnosis and need of revision of classification system of resorptive defects. PMID:26155588
Cao, Lu; Graauw, Marjo de; Yan, Kuan; Winkel, Leah; Verbeek, Fons J
2016-05-03
Endocytosis is regarded as a mechanism of attenuating the epidermal growth factor receptor (EGFR) signaling and of receptor degradation. There is increasing evidence becoming available showing that breast cancer progression is associated with a defect in EGFR endocytosis. In order to find related Ribonucleic acid (RNA) regulators in this process, high-throughput imaging with fluorescent markers is used to visualize the complex EGFR endocytosis process. Subsequently a dedicated automatic image and data analysis system is developed and applied to extract the phenotype measurement and distinguish different developmental episodes from a huge amount of images acquired through high-throughput imaging. For the image analysis, a phenotype measurement quantifies the important image information into distinct features or measurements. Therefore, the manner in which prominent measurements are chosen to represent the dynamics of the EGFR process becomes a crucial step for the identification of the phenotype. In the subsequent data analysis, classification is used to categorize each observation by making use of all prominent measurements obtained from image analysis. Therefore, a better construction for a classification strategy will support to raise the performance level in our image and data analysis system. In this paper, we illustrate an integrated analysis method for EGFR signalling through image analysis of microscopy images. Sophisticated wavelet-based texture measurements are used to obtain a good description of the characteristic stages in the EGFR signalling. A hierarchical classification strategy is designed to improve the recognition of phenotypic episodes of EGFR during endocytosis. Different strategies for normalization, feature selection and classification are evaluated. The results of performance assessment clearly demonstrate that our hierarchical classification scheme combined with a selected set of features provides a notable improvement in the temporal analysis of EGFR endocytosis. Moreover, it is shown that the addition of the wavelet-based texture features contributes to this improvement. Our workflow can be applied to drug discovery to analyze defected EGFR endocytosis processes.
1992-01-10
VIRUSES AND CHLAMYDIAE 0888 08889 OTHER SPECIFIED ARTHROPOD-BORNE DISEASE 0904 09040 JUVENILE NEUROSYPHILIS, UNSPECIFIED 0915 09150 SYPHILITIC UVEITIS...RETINAL DETACHMENT WITH RETINAL DEFECT, UNSPECIFIED 3611 36110 RETINOSCHISIS , UNSPECIFIED 3613 36130 RETINAL DEFECT, UNSPECIFIED 3618 36189 OTHER FORMS OF...ARTHROPATHIES, SITE UNSPECIFIED 7129 71290 UNSPECIFIED CRYSTAL ARTHROPATHY, SITE UNSPECIFIED 7143 71430 CHRONIC OR UNSPECIFIED POLYARTICULAR JUVENILE RHEUMATOI
Hoffmann, Jürgen; Wallwiener, Diethelm
2009-04-08
One of the basic prerequisites for generating evidence-based data is the availability of classification systems. Attempts to date to classify breast cancer operations have focussed on specific problems, e.g. the avoidance of secondary corrective surgery for surgical defects, rather than taking a generic approach. Starting from an existing, simpler empirical scheme based on the complexity of breast surgical procedures, which was used in-house primarily in operative report-writing, a novel classification of ablative and breast-conserving procedures initially needed to be developed and elaborated systematically. To obtain proof of principle, a prospectively planned analysis of patient records for all major breast cancer-related operations performed at our breast centre in 2005 and 2006 was conducted using the new classification. Data were analysed using basic descriptive statistics such as frequency tables. A novel two-type, six-tier classification system comprising 12 main categories, 13 subcategories and 39 sub-subcategories of oncological, oncoplastic and reconstructive breast cancer-related surgery was successfully developed. Our system permitted unequivocal classification, without exception, of all 1225 procedures performed in 1166 breast cancer patients in 2005 and 2006. Breast cancer-related surgical procedures can be generically classified according to their surgical complexity. Analysis of all major procedures performed at our breast centre during the study period provides proof of principle for this novel classification system. We envisage various applications for this classification, including uses in randomised clinical trials, guideline development, specialist surgical training, continuing professional development as well as quality of care and public health research.
Karimi, Mohammad H; Asemani, Davud
2014-05-01
Ceramic and tile industries should indispensably include a grading stage to quantify the quality of products. Actually, human control systems are often used for grading purposes. An automatic grading system is essential to enhance the quality control and marketing of the products. Since there generally exist six different types of defects originating from various stages of tile manufacturing lines with distinct textures and morphologies, many image processing techniques have been proposed for defect detection. In this paper, a survey has been made on the pattern recognition and image processing algorithms which have been used to detect surface defects. Each method appears to be limited for detecting some subgroup of defects. The detection techniques may be divided into three main groups: statistical pattern recognition, feature vector extraction and texture/image classification. The methods such as wavelet transform, filtering, morphology and contourlet transform are more effective for pre-processing tasks. Others including statistical methods, neural networks and model-based algorithms can be applied to extract the surface defects. Although, statistical methods are often appropriate for identification of large defects such as Spots, but techniques such as wavelet processing provide an acceptable response for detection of small defects such as Pinhole. A thorough survey is made in this paper on the existing algorithms in each subgroup. Also, the evaluation parameters are discussed including supervised and unsupervised parameters. Using various performance parameters, different defect detection algorithms are compared and evaluated. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Verechagin, V.; Kris, R.; Schwarzband, I.; Milstein, A.; Cohen, B.; Shkalim, A.; Levy, S.; Price, D.; Bal, E.
2018-03-01
Over the years, mask and wafers defects dispositioning has become an increasingly challenging and time consuming task. With design rules getting smaller, OPC getting complex and scanner illumination taking on free-form shapes - the probability of a user to perform accurate and repeatable classification of defects detected by mask inspection tools into pass/fail bins is reducing. The critical challenging of mask defect metrology for small nodes ( < 30 nm) was reviewed in [1]. While Critical Dimension (CD) variation measurement is still the method of choice for determining a mask defect future impact on wafer, the high complexity of OPCs combined with high variability in pattern shapes poses a challenge for any automated CD variation measurement method. In this study, a novel approach for measurement generalization is presented. CD variation assessment performance is evaluated on multiple different complex shape patterns, and is benchmarked against an existing qualified measurement methodology.
Vision-based in-line fabric defect detection using yarn-specific shape features
NASA Astrophysics Data System (ADS)
Schneider, Dorian; Aach, Til
2012-01-01
We develop a methodology for automatic in-line flaw detection in industrial woven fabrics. Where state of the art detection algorithms apply texture analysis methods to operate on low-resolved ({200 ppi) image data, we describe here a process flow to segment single yarns in high-resolved ({1000 ppi) textile images. Four yarn shape features are extracted, allowing a precise detection and measurement of defects. The degree of precision reached allows a classification of detected defects according to their nature, providing an innovation in the field of automatic fabric flaw detection. The design has been carried out to meet real time requirements and face adverse conditions caused by loom vibrations and dirt. The entire process flow is discussed followed by an evaluation using a database with real-life industrial fabric images. This work pertains to the construction of an on-loom defect detection system to be used in manufacturing practice.
Evaluation and integration of disparate classification systems for clefts of the lip
Wang, Kathie H.; Heike, Carrie L.; Clarkson, Melissa D.; Mejino, Jose L. V.; Brinkley, James F.; Tse, Raymond W.; Birgfeld, Craig B.; Fitzsimons, David A.; Cox, Timothy C.
2014-01-01
Orofacial clefting is a common birth defect with wide phenotypic variability. Many systems have been developed to classify cleft patterns to facilitate diagnosis, management, surgical treatment, and research. In this review, we examine the rationale for different existing classification schemes and determine their inter-relationships, as well as strengths and deficiencies for subclassification of clefts of the lip. The various systems differ in how they describe and define attributes of cleft lip (CL) phenotypes. Application and analysis of the CL classifications reveal discrepancies that may result in errors when comparing studies that use different systems. These inconsistencies in terminology, variable levels of subclassification, and ambiguity in some descriptions may confound analyses and impede further research aimed at understanding the genetics and etiology of clefts, development of effective treatment options for patients, as well as cross-institutional comparisons of outcome measures. Identification and reconciliation of discrepancies among existing systems is the first step toward creating a common standard to allow for a more explicit interpretation that will ultimately lead to a better understanding of the causes and manifestations of phenotypic variations in clefting. PMID:24860508
NASA Technical Reports Server (NTRS)
Shull, Forrest; Godfrey, Sally; Bechtel, Andre; Feldmann, Raimund L.; Regardie, Myrna; Seaman, Carolyn
2008-01-01
A viewgraph presentation describing the NASA Software Assurance Research Program (SARP) project, with a focus on full life-cycle defect management, is provided. The topics include: defect classification, data set and algorithm mapping, inspection guidelines, and tool support.
Di Spiezio Sardo, A; Campo, R; Gordts, S; Spinelli, M; Cosimato, C; Tanos, V; Brucker, S; Li, T C; Gergolet, M; De Angelis, C; Gianaroli, L; Grimbizis, G
2015-05-01
How comprehensive is the recently published European Society of Human Reproduction and Embryology (ESHRE)/European Society for Gynaecological Endoscopy (ESGE) classification system of female genital anomalies? The ESHRE/ESGE classification provides a comprehensive description and categorization of almost all of the currently known anomalies that could not be classified properly with the American Fertility Society (AFS) system. Until now, the more accepted classification system, namely that of the AFS, is associated with serious limitations in effective categorization of female genital anomalies. Many cases published in the literature could not be properly classified using the AFS system, yet a clear and accurate classification is a prerequisite for treatment. The CONUTA (CONgenital UTerine Anomalies) ESHRE/ESGE group conducted a systematic review of the literature to examine if those types of anomalies that could not be properly classified with the AFS system could be effectively classified with the use of the new ESHRE/ESGE system. An electronic literature search through Medline, Embase and Cochrane library was carried out from January 1988 to January 2014. Three participants independently screened, selected articles of potential interest and finally extracted data from all the included studies. Any disagreement was discussed and resolved after consultation with a fourth reviewer and the results were assessed independently and approved by all members of the CONUTA group. Among the 143 articles assessed in detail, 120 were finally selected reporting 140 cases that could not properly fit into a specific class of the AFS system. Those 140 cases were clustered in 39 different types of anomalies. The congenital anomaly involved a single organ in 12 (30.8%) out of the 39 types of anomalies, while multiple organs and/or segments of Müllerian ducts (complex anomaly) were involved in 27 (69.2%) types. Uterus was the organ most frequently involved (30/39: 76.9%), followed by cervix (26/39: 66.7%) and vagina (23/39: 59%). In all 39 types, the ESHRE/ESGE classification system provided a comprehensive description of each single or complex anomaly. A precise categorization was reached in 38 out of 39 types studied. Only one case of a bizarre uterine anomaly, with no clear embryological defect, could not be categorized and thus was placed in Class 6 (un-classified) of the ESHRE/ESGE system. The review of the literature was thorough but we cannot rule out the possibility that other defects exist which will also require testing in the new ESHRE/ESGE system. These anomalies, however, must be rare. The comprehensiveness of the ESHRE/ESGE classification adds objective scientific validity to its use. This may, therefore, promote its further dissemination and acceptance, which will have a positive outcome in clinical care and research. None. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology.
Neural attractor network for application in visual field data classification.
Fink, Wolfgang
2004-07-07
The purpose was to introduce a novel method for computer-based classification of visual field data derived from perimetric examination, that may act as a 'counsellor', providing an independent 'second opinion' to the diagnosing physician. The classification system consists of a Hopfield-type neural attractor network that obtains its input data from perimetric examination results. An iterative relaxation process determines the states of the neurons dynamically. Therefore, even 'noisy' perimetric output, e.g., early stages of a disease, may eventually be classified correctly according to the predefined idealized visual field defect (scotoma) patterns, stored as attractors of the network, that are found with diseases of the eye, optic nerve and the central nervous system. Preliminary tests of the classification system on real visual field data derived from perimetric examinations have shown a classification success of over 80%. Some of the main advantages of the Hopfield-attractor-network-based approach over feed-forward type neural networks are: (1) network architecture is defined by the classification problem; (2) no training is required to determine the neural coupling strengths; (3) assignment of an auto-diagnosis confidence level is possible by means of an overlap parameter and the Hamming distance. In conclusion, the novel method for computer-based classification of visual field data, presented here, furnishes a valuable first overview and an independent 'second opinion' in judging perimetric examination results, pointing towards a final diagnosis by a physician. It should not be considered a substitute for the diagnosing physician. Thanks to the worldwide accessibility of the Internet, the classification system offers a promising perspective towards modern computer-assisted diagnosis in both medicine and tele-medicine, for example and in particular, with respect to non-ophthalmic clinics or in communities where perimetric expertise is not readily available.
Microsurgical reconstruction of large nerve defects using autologous nerve grafts.
Daoutis, N K; Gerostathopoulos, N E; Efstathopoulos, D G; Misitizis, D P; Bouchlis, G N; Anagnostou, S K
1994-01-01
Between 1986 and 1993, 643 patients with peripheral nerve trauma were treated in our clinic. Primary neurorraphy was performed in 431 of these patients and nerve grafting in 212 patients. We present the functional results after nerve grafting in 93 patients with large nerve defects who were followed for more than 2 years. Evaluation of function was based on the Medical Research Council (MRC) classification for motor and sensory recovery. Factors affecting functional outcome, such as age of the patient, denervation time, length of the defect, and level of the injury were noted. Good results according to the MRC classification were obtained in the majority of cases, although function remained less than that of the uninjured side.
Nonlinear features for product inspection
NASA Astrophysics Data System (ADS)
Talukder, Ashit; Casasent, David P.
1999-03-01
Classification of real-time X-ray images of randomly oriented touching pistachio nuts is discussed. The ultimate objective is the development of a system for automated non-invasive detection of defective product items on a conveyor belt. We discuss the extraction of new features that allow better discrimination between damaged and clean items (pistachio nuts). This feature extraction and classification stage is the new aspect of this paper; our new maximum representation and discriminating feature (MRDF) extraction method computes nonlinear features that are used as inputs to a new modified k nearest neighbor classifier. In this work, the MRDF is applied to standard features (rather than iconic data). The MRDF is robust to various probability distributions of the input class and is shown to provide good classification and new ROC (receiver operating characteristic) data.
Chen, Min-Jie; Yang, Chi; Zheng, Ji-Si; Bai, Guo; Han, Zi-Xiang; Wang, Yi-Wen
2018-06-01
We sought to introduce our classification and reconstruction protocol for skull base erosions in the temporomandibular joint and skull base region. Patients with neoplasms in the temporomandibular joint and skull base region treated from January 2006 to March 2017 were reviewed. Skull base erosion was classified into 3 types according to the size of the defect. We included 33 patients, of whom 5 (15.2%) had type I defects (including 3 in whom free fat grafts were placed and 2 in whom deep temporal fascial fat flaps were placed). There were 8 patients (24.2%) with type II defects, all of whom received deep temporal fascial fat flaps. A total of 20 patients (60.6%) had type III defects, including 17 in whom autogenous bone grafts were placed, 1 in whom titanium mesh was placed, and 2 who received total alloplastic joints. The mean follow-up period was 50 months. All of the patients exhibited stable occlusion and good facial symmetry. No recurrence was noted. Our classification and reconstruction principles allowed reliable morpho-functional skull base reconstruction. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Influence of ECG measurement accuracy on ECG diagnostic statements.
Zywietz, C; Celikag, D; Joseph, G
1996-01-01
Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.
Tower, Amanda M; Frishman, Gary N
2013-01-01
The gynecologic sequelae due to deficient uterine scar healing after cesarean section are only recently being identified and described. These include conditions such as abnormal bleeding, pelvic pain, infertility, and cesarean scar ectopic pregnancy, as well as a potentially higher risk of complications and difficulties during gynecologic procedures such as uterine evacuation, hysterectomy, endometrial ablation, and insertion of an intrauterine device. The proposed mechanism of abnormal uterine bleeding is a pouch or "isthmocele" in the lower uterine segment that causes delayed menstrual bleeding. The prevalence of symptomatic or clinically relevant cesarean scar defects (CSDs) ranges from 19.4% to 88%. Possible risk factors for CSD include number of cesarean sections, uterine position, labor before cesarean section, and surgical technique used to close the uterine incision. There are no accepted guidelines for the diagnostic criteria of CSD. We propose that a CSD be defined on transvaginal ultrasound or saline infusion sonohysterography as a triangular hypoechoic defect in the myometrium at the site of the previous hysterotomy. We also propose a classification system to aid in standardized classification for future research. Surgical techniques for repair of CSD include laparoscopic excision, resectoscopic treatment, vaginal revision, and endometrial ablation. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.
A robust probabilistic collaborative representation based classification for multimodal biometrics
NASA Astrophysics Data System (ADS)
Zhang, Jing; Liu, Huanxi; Ding, Derui; Xiao, Jianli
2018-04-01
Most of the traditional biometric recognition systems perform recognition with a single biometric indicator. These systems have suffered noisy data, interclass variations, unacceptable error rates, forged identity, and so on. Due to these inherent problems, it is not valid that many researchers attempt to enhance the performance of unimodal biometric systems with single features. Thus, multimodal biometrics is investigated to reduce some of these defects. This paper proposes a new multimodal biometric recognition approach by fused faces and fingerprints. For more recognizable features, the proposed method extracts block local binary pattern features for all modalities, and then combines them into a single framework. For better classification, it employs the robust probabilistic collaborative representation based classifier to recognize individuals. Experimental results indicate that the proposed method has improved the recognition accuracy compared to the unimodal biometrics.
Oral function after maxillectomy and reconstruction with an obturator.
Kreeft, A M; Krap, M; Wismeijer, D; Speksnijder, C M; Smeele, L E; Bosch, S D; Muijen, M S A; Balm, A J M
2012-11-01
Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and maximal mouth opening). Outcomes were related to the extent of the resection (Brown maxillectomy classification), dentition and history of adjuvant radiotherapy. Maxillectomy defects ranged from 2-1 to 4B on the Brown classification, and most had a defect graded as 2-A or 2-B. Mean mixing ability test after 10 chewing strokes was 24.2 and after 20 chewing strokes 19.7, which compares to edentulous healthy individuals. None of the outcomes was influenced by Brown classification. Radiotherapy negatively influenced mean maximal mouth opening (29.1mm versus 40.9 mm, p=0.017) and subjective outcomes. Edentate obturated patients had worse outcomes than dentate patients, measured by mixing ability test and questionnaire. In conclusion, mastication after obturator reconstruction of a maxillectomy defect is comparable to mastication with full dentures. Size of the maxillectomy defect did not significantly influence functional outcome, but adjuvant radiotherapy resulted in worse mouth opening and self-reported oral and swallowing problems. Residual dentition had a positive influence on mastication and subjective outcomes. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
McDonald, Linda S; Panozzo, Joseph F; Salisbury, Phillip A; Ford, Rebecca
2016-01-01
Field peas (Pisum sativum L.) are generally traded based on seed appearance, which subjectively defines broad market-grades. In this study, we developed an objective Linear Discriminant Analysis (LDA) model to classify market grades of field peas based on seed colour, shape and size traits extracted from digital images. Seeds were imaged in a high-throughput system consisting of a camera and laser positioned over a conveyor belt. Six colour intensity digital images were captured (under 405, 470, 530, 590, 660 and 850nm light) for each seed, and surface height was measured at each pixel by laser. Colour, shape and size traits were compiled across all seed in each sample to determine the median trait values. Defective and non-defective seed samples were used to calibrate and validate the model. Colour components were sufficient to correctly classify all non-defective seed samples into correct market grades. Defective samples required a combination of colour, shape and size traits to achieve 87% and 77% accuracy in market grade classification of calibration and validation sample-sets respectively. Following these results, we used the same colour, shape and size traits to develop an LDA model which correctly classified over 97% of all validation samples as defective or non-defective.
McDonald, Linda S.; Panozzo, Joseph F.; Salisbury, Phillip A.; Ford, Rebecca
2016-01-01
Field peas (Pisum sativum L.) are generally traded based on seed appearance, which subjectively defines broad market-grades. In this study, we developed an objective Linear Discriminant Analysis (LDA) model to classify market grades of field peas based on seed colour, shape and size traits extracted from digital images. Seeds were imaged in a high-throughput system consisting of a camera and laser positioned over a conveyor belt. Six colour intensity digital images were captured (under 405, 470, 530, 590, 660 and 850nm light) for each seed, and surface height was measured at each pixel by laser. Colour, shape and size traits were compiled across all seed in each sample to determine the median trait values. Defective and non-defective seed samples were used to calibrate and validate the model. Colour components were sufficient to correctly classify all non-defective seed samples into correct market grades. Defective samples required a combination of colour, shape and size traits to achieve 87% and 77% accuracy in market grade classification of calibration and validation sample-sets respectively. Following these results, we used the same colour, shape and size traits to develop an LDA model which correctly classified over 97% of all validation samples as defective or non-defective. PMID:27176469
Development of algorithms for detecting citrus canker based on hyperspectral reflectance imaging.
Li, Jiangbo; Rao, Xiuqin; Ying, Yibin
2012-01-15
Automated discrimination of fruits with canker from other fruit with normal surface and different type of peel defects has become a helpful task to enhance the competitiveness and profitability of the citrus industry. Over the last several years, hyperspectral imaging technology has received increasing attention in the agricultural products inspection field. This paper studied the feasibility of classification of citrus canker from other peel conditions including normal surface and nine peel defects by hyperspectal imaging. A combination algorithm based on principal component analysis and the two-band ratio (Q(687/630)) method was proposed. Since fewer wavelengths were desired in order to develop a rapid multispectral imaging system, the canker classification performance of the two-band ratio (Q(687/630)) method alone was also evaluated. The proposed combination approach and two-band ratio method alone resulted in overall classification accuracy for training set samples and test set samples of 99.5%, 84.5% and 98.2%, 82.9%, respectively. The proposed combination approach was more efficient for classifying canker against various conditions under reflectance hyperspectral imagery. However, the two-band ratio (Q(687/630)) method alone also demonstrated effectiveness in discriminating citrus canker from normal fruit and other peel diseases except for copper burn and anthracnose. Copyright © 2011 Society of Chemical Industry.
SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.
Liu, Zhenjiang; Yuan, Zhengwei; Zhao, Qun
2014-01-01
Neural tube defects (NTDs) are common birth defects, whose specific biomarkers are needed. The purpose of this pilot study is to determine whether protein profiling in NTD-mothers differ from normal controls using SELDI-TOF-MS. ProteinChip Biomarker System was used to evaluate 82 maternal serum samples, 78 urine samples and 76 amniotic fluid samples. The validity of classification tree was then challenged with a blind test set including another 20 NTD-mothers and 18 controls in serum samples, and another 19 NTD-mothers and 17 controls in urine samples, and another 20 NTD-mothers and 17 controls in amniotic fluid samples. Eight proteins detected in serum samples were up-regulated and four proteins were down-regulated in the NTD group. Four proteins detected in urine samples were up-regulated and one protein was down-regulated in the NTD group. Six proteins detected in amniotic fluid samples were up-regulated and one protein was down-regulated in the NTD group. The classification tree for serum samples separated NTDs from healthy individuals, achieving a sensitivity of 91% and a specificity of 97% in the training set, and achieving a sensitivity of 90% and a specificity of 97% and a positive predictive value of 95% in the test set. The classification tree for urine samples separated NTDs from controls, achieving a sensitivity of 95% and a specificity of 94% in the training set, and achieving a sensitivity of 89% and a specificity of 82% and a positive predictive value of 85% in the test set. The classification tree for amniotic fluid samples separated NTDs from controls, achieving a sensitivity of 93% and a specificity of 89% in the training set, and achieving a sensitivity of 90% and a specificity of 88% and a positive predictive value of 90% in the test set. These suggest that SELDI-TOF-MS is an additional method for NTDs pregnancies detection.
Occurrence of Conotruncal Heart Birth Defects in Texas: A Comparison of Urban/Rural Classifications
ERIC Educational Resources Information Center
Langlois, Peter H.; Jandle, Leigh; Scheuerle, Angela; Horel, Scott A.; Carozza, Susan E.
2010-01-01
Purpose: (1) Determine if there is an association between 3 conotruncal heart birth defects and urban/rural residence of mother. (2) Compare results using different methods of measuring urban/rural status. Methods: Data were taken from the Texas Birth Defects Registry, 1999-2003. Poisson regression was used to compare crude and adjusted birth…
Di Spiezio Sardo, A.; Campo, R.; Gordts, S.; Spinelli, M.; Cosimato, C.; Tanos, V.; Brucker, S.; Li, T. C.; Gergolet, M.; De Angelis, C.; Gianaroli, L.; Grimbizis, G.
2015-01-01
STUDY QUESTION How comprehensive is the recently published European Society of Human Reproduction and Embryology (ESHRE)/European Society for Gynaecological Endoscopy (ESGE) classification system of female genital anomalies? SUMMARY ANSWER The ESHRE/ESGE classification provides a comprehensive description and categorization of almost all of the currently known anomalies that could not be classified properly with the American Fertility Society (AFS) system. WHAT IS KNOWN ALREADY Until now, the more accepted classification system, namely that of the AFS, is associated with serious limitations in effective categorization of female genital anomalies. Many cases published in the literature could not be properly classified using the AFS system, yet a clear and accurate classification is a prerequisite for treatment. STUDY DESIGN, SIZE AND DURATION The CONUTA (CONgenital UTerine Anomalies) ESHRE/ESGE group conducted a systematic review of the literature to examine if those types of anomalies that could not be properly classified with the AFS system could be effectively classified with the use of the new ESHRE/ESGE system. An electronic literature search through Medline, Embase and Cochrane library was carried out from January 1988 to January 2014. Three participants independently screened, selected articles of potential interest and finally extracted data from all the included studies. Any disagreement was discussed and resolved after consultation with a fourth reviewer and the results were assessed independently and approved by all members of the CONUTA group. PARTICIPANTS/MATERIALS, SETTING, METHODS Among the 143 articles assessed in detail, 120 were finally selected reporting 140 cases that could not properly fit into a specific class of the AFS system. Those 140 cases were clustered in 39 different types of anomalies. MAIN RESULTS AND THE ROLE OF CHANCE The congenital anomaly involved a single organ in 12 (30.8%) out of the 39 types of anomalies, while multiple organs and/or segments of Müllerian ducts (complex anomaly) were involved in 27 (69.2%) types. Uterus was the organ most frequently involved (30/39: 76.9%), followed by cervix (26/39: 66.7%) and vagina (23/39: 59%). In all 39 types, the ESHRE/ESGE classification system provided a comprehensive description of each single or complex anomaly. A precise categorization was reached in 38 out of 39 types studied. Only one case of a bizarre uterine anomaly, with no clear embryological defect, could not be categorized and thus was placed in Class 6 (un-classified) of the ESHRE/ESGE system. LIMITATIONS, REASONS FOR CAUTION The review of the literature was thorough but we cannot rule out the possibility that other defects exist which will also require testing in the new ESHRE/ESGE system. These anomalies, however, must be rare. WIDER IMPLICATIONS OF THE FINDINGS The comprehensiveness of the ESHRE/ESGE classification adds objective scientific validity to its use. This may, therefore, promote its further dissemination and acceptance, which will have a positive outcome in clinical care and research. STUDY FUNDING/COMPETING INTEREST(S) None. PMID:25788565
A low-cost machine vision system for the recognition and sorting of small parts
NASA Astrophysics Data System (ADS)
Barea, Gustavo; Surgenor, Brian W.; Chauhan, Vedang; Joshi, Keyur D.
2018-04-01
An automated machine vision-based system for the recognition and sorting of small parts was designed, assembled and tested. The system was developed to address a need to expose engineering students to the issues of machine vision and assembly automation technology, with readily available and relatively low-cost hardware and software. This paper outlines the design of the system and presents experimental performance results. Three different styles of plastic gears, together with three different styles of defective gears, were used to test the system. A pattern matching tool was used for part classification. Nine experiments were conducted to demonstrate the effects of changing various hardware and software parameters, including: conveyor speed, gear feed rate, classification, and identification score thresholds. It was found that the system could achieve a maximum system accuracy of 95% at a feed rate of 60 parts/min, for a given set of parameter settings. Future work will be looking at the effect of lighting.
Luminescent Method for Porcelain Identification
NASA Astrophysics Data System (ADS)
Platova, R. A.; Rassulov, V. A.; Platov, Yu. T.
2018-05-01
Porcelain identification according to the material type (hard, soft, and bone) was reduced to a system of classification functions that were constructed based on interrelationships of luminescence band intensities of optically active impurity centers (Fe3+ and Mn2+), a molecular center ({UO}_2^{2+}) , and intrinsic defects (O*, oxygen center). Porcelains with different compositions and calcination conditions had different combinations and intensity ratios of bands of optically active centers.
Micro-bridge defects: characterization and root cause analysis
NASA Astrophysics Data System (ADS)
Santoro, Gaetano; Van den Heuvel, Dieter; Braggin, Jennifer; Rosslee, Craig; Leray, Philippe J.; Cheng, Shaunee; Jehoul, Christiane; Schreutelkamp, Robert; Hillel, Noam
2010-03-01
Defect review of advanced lithography processes is becoming more and more challenging as feature sizes decrease. Previous studies using a defect review SEM on immersion lithography generated wafers have resulted in a defect classification scheme which, among others, includes a category for micro-bridges. Micro-bridges are small connections between two adjacent lines in photo-resist and are considered device killing defects. Micro-bridge rates also tend to increase as feature sizes decrease, making them even more important for the next technology nodes. Especially because micro-bridge defects can originate from different root causes, the need to further refine and split up the classification of this type of defect into sub groups may become a necessity. This paper focuses on finding the correlation of the different types of micro-bridge defects to a particular root cause based on a full characterization and root cause analysis of this class of defects, by using advanced SEM review capabilities like high quality imaging in very low FOV, Multi Perspective SEM Imaging (MPSI), tilted column and rotated stage (Tilt&Rotation) imaging and Focused Ion Beam (FIB) cross sectioning. Immersion lithography material has been mainly used to generate the set of data presented in this work even though, in the last part of the results, some EUV lithography data will be presented as part of the continuing effort to extend the micro-bridge defect characterization to the EUV technology on 40 nm technology node and beyond.
A developmental and genetic classification for midbrain-hindbrain malformations
Millen, Kathleen J.; Dobyns, William B.
2009-01-01
Advances in neuroimaging, developmental biology and molecular genetics have increased the understanding of developmental disorders affecting the midbrain and hindbrain, both as isolated anomalies and as part of larger malformation syndromes. However, the understanding of these malformations and their relationships with other malformations, within the central nervous system and in the rest of the body, remains limited. A new classification system is proposed, based wherever possible, upon embryology and genetics. Proposed categories include: (i) malformations secondary to early anteroposterior and dorsoventral patterning defects, or to misspecification of mid-hindbrain germinal zones; (ii) malformations associated with later generalized developmental disorders that significantly affect the brainstem and cerebellum (and have a pathogenesis that is at least partly understood); (iii) localized brain malformations that significantly affect the brain stem and cerebellum (pathogenesis partly or largely understood, includes local proliferation, cell specification, migration and axonal guidance); and (iv) combined hypoplasia and atrophy of putative prenatal onset degenerative disorders. Pertinent embryology is discussed and the classification is justified. This classification will prove useful for both physicians who diagnose and treat patients with these disorders and for clinical scientists who wish to understand better the perturbations of developmental processes that produce them. Importantly, both the classification and its framework remain flexible enough to be easily modified when new embryologic processes are described or new malformations discovered. PMID:19933510
Borràs, Eva; Ferré, Joan; Boqué, Ricard; Mestres, Montserrat; Aceña, Laura; Calvo, Angels; Busto, Olga
2016-07-15
Three instrumental techniques, headspace-mass spectrometry (HS-MS), mid-infrared spectroscopy (MIR) and UV-visible spectrophotometry (UV-vis), have been combined to classify virgin olive oil samples based on the presence or absence of sensory defects. The reference sensory values were provided by an official taste panel. Different data fusion strategies were studied to improve the discrimination capability compared to using each instrumental technique individually. A general model was applied to discriminate high-quality non-defective olive oils (extra-virgin) and the lowest-quality olive oils considered non-edible (lampante). A specific identification of key off-flavours, such as musty, winey, fusty and rancid, was also studied. The data fusion of the three techniques improved the classification results in most of the cases. Low-level data fusion was the best strategy to discriminate musty, winey and fusty defects, using HS-MS, MIR and UV-vis, and the rancid defect using only HS-MS and MIR. The mid-level data fusion approach using partial least squares-discriminant analysis (PLS-DA) scores was found to be the best strategy for defective vs non-defective and edible vs non-edible oil discrimination. However, the data fusion did not sufficiently improve the results obtained by a single technique (HS-MS) to classify non-defective classes. These results indicate that instrumental data fusion can be useful for the identification of sensory defects in virgin olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wood industrial application for quality control using image processing
NASA Astrophysics Data System (ADS)
Ferreira, M. J. O.; Neves, J. A. C.
1994-11-01
This paper describes an application of image processing for the furniture industry. It uses an input data, images acquired directly from wood planks where defects were previously marked by an operator. A set of image processing algorithms separates and codes each defect and detects a polygonal approach of the line representing them. For such a purpose we developed a pattern classification algorithm and a new technique of segmenting defects by carving the convex hull of the binary shape representing each isolated defect.
Houyel, Lucile; Khoshnood, Babak; Anderson, Robert H; Lelong, Nathalie; Thieulin, Anne-Claire; Goffinet, François; Bonnet, Damien
2011-10-03
Classification of the overall spectrum of congenital heart defects (CHD) has always been challenging, in part because of the diversity of the cardiac phenotypes, but also because of the oft-complex associations. The purpose of our study was to establish a comprehensive and easy-to-use classification of CHD for clinical and epidemiological studies based on the long list of the International Paediatric and Congenital Cardiac Code (IPCCC). We coded each individual malformation using six-digit codes from the long list of IPCCC. We then regrouped all lesions into 10 categories and 23 subcategories according to a multi-dimensional approach encompassing anatomic, diagnostic and therapeutic criteria. This anatomic and clinical classification of congenital heart disease (ACC-CHD) was then applied to data acquired from a population-based cohort of patients with CHD in France, made up of 2867 cases (82% live births, 1.8% stillbirths and 16.2% pregnancy terminations). The majority of cases (79.5%) could be identified with a single IPCCC code. The category "Heterotaxy, including isomerism and mirror-imagery" was the only one that typically required more than one code for identification of cases. The two largest categories were "ventricular septal defects" (52%) and "anomalies of the outflow tracts and arterial valves" (20% of cases). Our proposed classification is not new, but rather a regrouping of the known spectrum of CHD into a manageable number of categories based on anatomic and clinical criteria. The classification is designed to use the code numbers of the long list of IPCCC but can accommodate ICD-10 codes. Its exhaustiveness, simplicity, and anatomic basis make it useful for clinical and epidemiologic studies, including those aimed at assessment of risk factors and outcomes.
Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee
2017-08-01
Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.
New nonlinear features for inspection, robotics, and face recognition
NASA Astrophysics Data System (ADS)
Casasent, David P.; Talukder, Ashit
1999-10-01
Classification of real-time X-ray images of randomly oriented touching pistachio nuts is discussed. The ultimate objective is the development of a system for automated non- invasive detection of defective product items on a conveyor belt. We discuss the extraction of new features that allow better discrimination between damaged and clean items (pistachio nuts). This feature extraction and classification stage is the new aspect of this paper; our new maximum representation and discriminating feature (MRDF) extraction method computes nonlinear features that are used as inputs to a new modified k nearest neighbor classifier. In this work, the MRDF is applied to standard features (rather than iconic data). The MRDF is robust to various probability distributions of the input class and is shown to provide good classification and new ROC (receiver operating characteristic) data. Other applications of these new feature spaces in robotics and face recognition are also noted.
Signal processing for non-destructive testing of railway tracks
NASA Astrophysics Data System (ADS)
Heckel, Thomas; Casperson, Ralf; Rühe, Sven; Mook, Gerhard
2018-04-01
Increased speed, heavier loads, altered material and modern drive systems result in an increasing number of rail flaws. The appearance of these flaws also changes continually due to the rapid change in damage mechanisms of modern rolling stock. Hence, interpretation has become difficult when evaluating non-destructive rail testing results. Due to the changed interplay between detection methods and flaws, the recorded signals may result in unclassified types of rail flaws. Methods for automatic rail inspection (according to defect detection and classification) undergo continual development. Signal processing is a key technology to master the challenge of classification and maintain resolution and detection quality, independent of operation speed. The basic ideas of signal processing, based on the Glassy-Rail-Diagram for classification purposes, are presented herein. Examples for the detection of damages caused by rolling contact fatigue also are given, and synergetic effects of combined evaluation of diverse inspection methods are shown.
21 CFR 864.8100 - Bothrops atrox reagent.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Identification. A Bothrops atrox reagent is a device made from snake venom and used to determine blood fibrinogen... the treatment of thrombosis) or as an aid in the classification of dysfibrinogenemia (presence in the plasma of functionally defective fibrinogen). (b) Classification. Class II (performance standards). [45...
21 CFR 864.8100 - Bothrops atrox reagent.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Identification. A Bothrops atrox reagent is a device made from snake venom and used to determine blood fibrinogen... the treatment of thrombosis) or as an aid in the classification of dysfibrinogenemia (presence in the plasma of functionally defective fibrinogen). (b) Classification. Class II (performance standards). [45...
Sibiude, Jeanne; Mandelbrot, Laurent; Blanche, Stéphane; Le Chenadec, Jérôme; Boullag-Bonnet, Naima; Faye, Albert; Dollfus, Catherine; Tubiana, Roland; Bonnet, Damien; Lelong, Nathalie; Khoshnood, Babak; Warszawski, Josiane
2014-01-01
Background Antiretroviral therapy (ART) has major benefits during pregnancy, both for maternal health and to prevent mother-to-child transmission of HIV. Safety issues, including teratogenic risk, need to be evaluated. We estimated the prevalence of birth defects in children born to HIV-infected women receiving ART during pregnancy, and assessed the independent association of birth defects with each antiretroviral (ARV) drug used. Methods and Findings The French Perinatal Cohort prospectively enrolls HIV-infected women delivering in 90 centers throughout France. Children are followed by pediatricians until 2 y of age according to national guidelines. We included 13,124 live births between 1994 and 2010, among which, 42% (n = 5,388) were exposed to ART in the first trimester of pregnancy. Birth defects were studied using both European Surveillance of Congenital Anomalies (EUROCAT) and Metropolitan Atlanta Congenital Defects Program (MACDP) classifications; associations with ART were evaluated using univariate and multivariate logistic regressions. Correction for multiple comparisons was not performed because the analyses were based on hypotheses emanating from previous findings in the literature and the robustness of the findings of the current study. The prevalence of birth defects was 4.4% (95% CI 4.0%–4.7%), according to the EUROCAT classification. In multivariate analysis adjusting for other ARV drugs, maternal age, geographical origin, intravenous drug use, and type of maternity center, a significant association was found between exposure to zidovudine in the first trimester and congenital heart defects: 2.3% (74/3,267), adjusted odds ratio (AOR) = 2.2 (95% CI 1.3–3.7), p = 0.003, absolute risk difference attributed to zidovudine +1.2% (95% CI +0.5; +1.9%). Didanosine and indinavir were associated with head and neck defects, respectively: 0.5%, AOR = 3.4 (95% CI 1.1–10.4), p = 0.04; 0.9%, AOR = 3.8 (95% CI 1.1–13.8), p = 0.04. We found a significant association between efavirenz and neurological defects (n = 4) using the MACDP classification: AOR = 3.0 (95% CI 1.1–8.5), p = 0.04, absolute risk +0.7% (95% CI +0.07%; +1.3%). But the association was not significant using the less inclusive EUROCAT classification: AOR = 2.1 (95% CI 0.7–5.9), p = 0.16. No association was found between birth defects and lopinavir or ritonavir with a power >85% for an odds ratio of 1.5, nor for nevirapine, tenofovir, stavudine, or abacavir with a power >70%. Limitations of the present study were the absence of data on termination of pregnancy, stillbirths, tobacco and alcohol intake, and concomitant medication. Conclusions We found a specific association between in utero exposure to zidovudine and heart defects; the mechanisms need to be elucidated. The association between efavirenz and neurological defects must be interpreted with caution. For the other drugs not associated with birth defects, the results were reassuring. Finally, whatever the impact that some ARV drugs may have on birth defects, it is surpassed by the major role of ART in the successful prevention of mother-to-child transmission of HIV. Please see later in the article for the Editors' Summary PMID:24781315
Recognition and defect detection of dot-matrix text via variation-model based learning
NASA Astrophysics Data System (ADS)
Ohyama, Wataru; Suzuki, Koushi; Wakabayashi, Tetsushi
2017-03-01
An algorithm for recognition and defect detection of dot-matrix text printed on products is proposed. Extraction and recognition of dot-matrix text contains several difficulties, which are not involved in standard camera-based OCR, that the appearance of dot-matrix characters is corrupted and broken by illumination, complex texture in the background and other standard characters printed on product packages. We propose a dot-matrix text extraction and recognition method which does not require any user interaction. The method employs detected location of corner points and classification score. The result of evaluation experiment using 250 images shows that recall and precision of extraction are 78.60% and 76.03%, respectively. Recognition accuracy of correctly extracted characters is 94.43%. Detecting printing defect of dot-matrix text is also important in the production scene to avoid illegal productions. We also propose a detection method for printing defect of dot-matrix characters. The method constructs a feature vector of which elements are classification scores of each character class and employs support vector machine to classify four types of printing defect. The detection accuracy of the proposed method is 96.68 %.
[Incidence and evolution of congenital heart disease in Spain from 2003 until 2012].
Pérez-Lescure Picarzo, Javier; Mosquera González, Margarita; Latasa Zamalloa, Pello; Crespo Marcos, David
2018-03-29
Congenital heart disease (CHD) represents the most common congenital malformation. The objective of this study was to analyse the incidence of CHD in Spain, and it is the first nationwide study so far. A retrospective observational study was performed in order to evaluate the incidence of CHD in Spain. The administrative database (minimum basic data set) from 2003 to 2012 was analysed in children less than one year old admitted to hospital with codes of CHD (International Classification of Diseases, 9th Revision, clinical modification). Cumulative incidence, Incidence relative risk, and standardised incidence ratio were calculated to study geographic variations. There were 64,831 infants with CHD among the 4,766,325 births analysed during the period studied, with an incidence of 13.6‰. The incidence excluding atrial septal defect was 7.29 ‰.The most frequent CHD were atrial septal defect (6.31‰), ventricular septal defect (3.48‰), patent ductus arteriosus (2.71‰), coarctation of the aorta (0.55‰), pulmonary stenosis (0.50‰), transposition of the great arteries (0.49‰), atrioventricular septal defect (0.45‰), and tetralogy of Fallot (0.41‰). Castilla and Leon, together with Extremadura, showed the highest risks for severe and very severe CHD, while Madrid and Cantabria showed the lowest. An increase of mild CHD was observed during the period analysed. This could have been influenced by improvements in diagnostic techniques, extended use of echocardiography, and the International Classification of Diseases, 9th Revision, clinical modification coding system, and to a decrease in very severe CHD, which is less influenced by external factors. Significant geographical differences were found in the incidence of severe and very severe CHD. Copyright © 2018. Publicado por Elsevier España, S.L.U.
7 CFR 51.1439 - Tolerances for defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... for shell, center wall, and foreign material; (2) 3 percent for portions of kernels which are “dark amber” or darker color, or darker than any specified lighter color classification but which are not... which are “dark amber” or darker color, or darker than any specified lighter color classification. (b) U...
7 CFR 51.1439 - Tolerances for defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... for shell, center wall, and foreign material; (2) 3 percent for portions of kernels which are “dark amber” or darker color, or darker than any specified lighter color classification but which are not... which are “dark amber” or darker color, or darker than any specified lighter color classification. (b) U...
Giacomelli, Roberto; Di Cesare, Ernesto; Cipriani, Paola; Ruscitti, Piero; Di Sibio, Alessandra; Liakouli, Vasiliki; Gennarelli, Antonio; Carubbi, Francesco; Splendiani, Alessandra; Berardicurti, Onorina; Di Benedetto, Paola; Ciccia, Francesco; Guggino, Giuliana; Radchenko, Ganna; Triolo, Giovanni; Masciocchi, Carlo
2017-09-01
To evaluate occult cardiac involvement in asymptomatic systemic sclerosis (SSc) patients by pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance (CMR), for a very early identification of patients at higher risk of cardiac-related mortality. Sixteen consecutive patients with definite SSc, fulfilling the American College of Rheumatology/European League Against Rheumatism 2013 classification criteria in less than 1 year from the onset of Raynaud's phenomenon, underwent pharmacological stress, rest perfusion and delayed enhancement CMR. At enrollment, no patient showed signs and/or symptoms suggestive for cardiac involvement. No patient showed traditional cardiovascular risk factors. Both the 12-lead electrocardiogram examination and echocardiographic evaluation did not show any alterations in our cohort. Stress perfusion defects of left ventricle were detected in six out of 16 (37.5%) patients and these defects did not match with the coronary flow distribution. The results showed the presence of two different patterns of stress perfusion defects: sub-endocardial and/or a midmyocardial. The presence of stress perfusion defects did not correlate with any clinical feature of enrolled patients. Myocardial stress perfusion defects may be detected early by pharmacological stress perfusion CMR, a reliable and sensitive technique for the noninvasive evaluation of SSc heart disease, in patients with SSc of recent onset. These defects seem to be independent from traditional risk factors and associated comorbidities, suggesting they are a specific hallmark of the disease. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.
Furenäs, Eva; Eriksson, Peter; Wennerholm, Ulla-Britt; Dellborg, Mikael
2017-09-15
There is an increasing prevalence of women with congenital heart defects reaching childbearing age. In western countries women tend to give birth at a higher age compared to some decades ago. We evaluated the CARdiac disease in PREGnancy (CARPREG) and modified World Health Organization (mWHO) risk classifications for cardiac complications during pregnancies in women with congenital heart defects and analyzed the impact of age on risk of obstetric and fetal outcome. A single-center observational study of cardiac, obstetric, and neonatal complications with data from cardiac and obstetric records of pregnancies in women with congenital heart disease. Outcomes of 496 pregnancies in 232 women, including induced abortion, miscarriage, stillbirth, and live birth were analyzed regarding complications, maternal age, mode of delivery, and two risk classifications: CARPREG and mWHO. There were 28 induced abortions, 59 fetal loss, 409 deliveries with 412 neonates. Cardiac (14%), obstetric (14%), and neonatal (15%) complications were noted, including one maternal death and five stillbirths. The rate of cesarean section was 19%. Age above 35years was of borderline importance for cardiac complications (p=0.054) and was not a significant additional risk factor for obstetric or neonatal complications. Both risk classifications had moderate clinical utility, with area under the curve (AUC) 0.71 for CARPREG and 0.65 for mWHO on cardiac complications. Pregnancy complications in women with congenital heart disease are common but severe complications are rare. Advanced maternal age does not seem to affect complication rate. Existing risk classification systems are insufficient in predicting complications. Copyright © 2017 Elsevier B.V. All rights reserved.
Log Defect Recognition Using CT-images and Neural Net Classifiers
Daniel L. Schmoldt; Pei Li; A. Lynn Abbott
1995-01-01
Although several approaches have been introduced to automatically identify internal log defects using computed tomography (CT) imagery, most of these have been feasibility efforts and consequently have had several limitations: (1) reports of classification accuracy are largely subjective, not statistical, (2) there has been no attempt to achieve real-time operation,...
Barth, Albert D; Waldner, Cheryl L
2002-04-01
Breeding soundness evaluation records from 2110 beef bulls, for the period of 1986 to 1999, were analyzed to determine the prevalence and importance of factors affecting breeding soundness classification. The percentage of all bulls classified as satisfactory ranged from 49.0% in January to 73.3% in May. The percentage of physically normal bulls with satisfactory semen quality ranged from 65.7% in January to 87.5% in June. Poor body condition or excessive body condition, below average or below the recommended minimum scrotal circumference, lameness, and severe scrotal frostbite significantly reduced the probability of a satisfactory breeding soundness classification. The percentage of sperm with midpiece defects declined significantly and the percentage of sperm with head defects increased significantly with the approach of summer. Photoperiod, cold stress, poor or excessive body condition, and reduced feed quality may interact to reduce semen quality in the winter months.
Kim, Young-Ho
2017-09-01
The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.
2018-03-01
computational parameters needs to be established. We used density functional theory to compute defect formation energies of the neutral and charged hh... energies for the 3A to 3E transition (absorption, zero phonon lines, and emission), which is essential for optical initialization and read-out. We...PBE, defect formation energy , charge transition levels, absorption, zero phonon lines, emission 16. SECURITY CLASSIFICATION OF: 17. LIMITATION
Characterization and classification of zebrafish brain morphology mutants
Lowery, Laura Anne; De Rienzo, Gianluca; Gutzman, Jennifer H.; Sive, Hazel
2010-01-01
The mechanisms by which the vertebrate brain achieves its three-dimensional structure are clearly complex, requiring the functions of many genes. Using the zebrafish as a model, we have begun to define genes required for brain morphogenesis, including brain ventricle formation, by studying 16 mutants previously identified as having embryonic brain morphology defects. We report the phenotypic characterization of these mutants at several time-points, using brain ventricle dye injection, imaging, and immunohistochemistry with neuronal markers. Most of these mutants display early phenotypes, affecting initial brain shaping, while others show later phenotypes, affecting brain ventricle expansion. In the early phenotype group, we further define four phenotypic classes and corresponding functions required for brain morphogenesis. Although we did not use known genotypes for this classification, basing it solely on phenotypes, many mutants with defects in functionally related genes clustered in a single class. In particular, class 1 mutants show midline separation defects, corresponding to epithelial junction defects; class 2 mutants show reduced brain ventricle size; class 3 mutants show midbrain-hindbrain abnormalities, corresponding to basement membrane defects; and class 4 mutants show absence of ventricle lumen inflation, corresponding to defective ion pumping. Later brain ventricle expansion requires the extracellular matrix, cardiovascular circulation, and transcription/splicing-dependent events. We suggest that these mutants define processes likely to be used during brain morphogenesis throughout the vertebrates. PMID:19051268
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1837 Classification of...) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Florida Grapefruit Definitions § 51.784 Classification of.... Dryness or mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the... more than 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1837 Classification of...) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS) United States Standards for Grades of Florida Grapefruit Definitions § 51.784 Classification of... discoloration permitted in the grade Very deep or very rough aggregating more than a circle 1/2 inch (12.7 mm) in diameter; deep or rough aggregating more than a circle 1 inch (25.4 mm) in diameter; slightly...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1837 Classification of....1828.] Deep or rough aggregating more than a circle 1/4 inch (6.4 mm) in diameter; slightly rough with... slight depth aggregating more than a circle 11/8 inches (28.6 mm) in diameter Deep or rough aggregating...
Adaptive classifier for steel strip surface defects
NASA Astrophysics Data System (ADS)
Jiang, Mingming; Li, Guangyao; Xie, Li; Xiao, Mang; Yi, Li
2017-01-01
Surface defects detection system has been receiving increased attention as its precision, speed and less cost. One of the most challenges is reacting to accuracy deterioration with time as aged equipment and changed processes. These variables will make a tiny change to the real world model but a big impact on the classification result. In this paper, we propose a new adaptive classifier with a Bayes kernel (BYEC) which update the model with small sample to it adaptive for accuracy deterioration. Firstly, abundant features were introduced to cover lots of information about the defects. Secondly, we constructed a series of SVMs with the random subspace of the features. Then, a Bayes classifier was trained as an evolutionary kernel to fuse the results from base SVMs. Finally, we proposed the method to update the Bayes evolutionary kernel. The proposed algorithm is experimentally compared with different algorithms, experimental results demonstrate that the proposed method can be updated with small sample and fit the changed model well. Robustness, low requirement for samples and adaptive is presented in the experiment.
Defect inspection in hot slab surface: multi-source CCD imaging based fuzzy-rough sets method
NASA Astrophysics Data System (ADS)
Zhao, Liming; Zhang, Yi; Xu, Xiaodong; Xiao, Hong; Huang, Chao
2016-09-01
To provide an accurate surface defects inspection method and make the automation of robust image region of interests(ROI) delineation strategy a reality in production line, a multi-source CCD imaging based fuzzy-rough sets method is proposed for hot slab surface quality assessment. The applicability of the presented method and the devised system are mainly tied to the surface quality inspection for strip, billet and slab surface etcetera. In this work we take into account the complementary advantages in two common machine vision (MV) systems(line array CCD traditional scanning imaging (LS-imaging) and area array CCD laser three-dimensional (3D) scanning imaging (AL-imaging)), and through establishing the model of fuzzy-rough sets in the detection system the seeds for relative fuzzy connectedness(RFC) delineation for ROI can placed adaptively, which introduces the upper and lower approximation sets for RIO definition, and by which the boundary region can be delineated by RFC region competitive classification mechanism. For the first time, a Multi-source CCD imaging based fuzzy-rough sets strategy is attempted for CC-slab surface defects inspection that allows an automatic way of AI algorithms and powerful ROI delineation strategies to be applied to the MV inspection field.
Hyperspectral range imaging for transportation systems evaluation
NASA Astrophysics Data System (ADS)
Bridgelall, Raj; Rafert, J. B.; Atwood, Don; Tolliver, Denver D.
2016-04-01
Transportation agencies expend significant resources to inspect critical infrastructure such as roadways, railways, and pipelines. Regular inspections identify important defects and generate data to forecast maintenance needs. However, cost and practical limitations prevent the scaling of current inspection methods beyond relatively small portions of the network. Consequently, existing approaches fail to discover many high-risk defect formations. Remote sensing techniques offer the potential for more rapid and extensive non-destructive evaluations of the multimodal transportation infrastructure. However, optical occlusions and limitations in the spatial resolution of typical airborne and space-borne platforms limit their applicability. This research proposes hyperspectral image classification to isolate transportation infrastructure targets for high-resolution photogrammetric analysis. A plenoptic swarm of unmanned aircraft systems will capture images with centimeter-scale spatial resolution, large swaths, and polarization diversity. The light field solution will incorporate structure-from-motion techniques to reconstruct three-dimensional details of the isolated targets from sequences of two-dimensional images. A comparative analysis of existing low-power wireless communications standards suggests an application dependent tradeoff in selecting the best-suited link to coordinate swarming operations. This study further produced a taxonomy of specific roadway and railway defects, distress symptoms, and other anomalies that the proposed plenoptic swarm sensing system would identify and characterize to estimate risk levels.
A Method for Automatic Surface Inspection Using a Model-Based 3D Descriptor.
Madrigal, Carlos A; Branch, John W; Restrepo, Alejandro; Mery, Domingo
2017-10-02
Automatic visual inspection allows for the identification of surface defects in manufactured parts. Nevertheless, when defects are on a sub-millimeter scale, detection and recognition are a challenge. This is particularly true when the defect generates topological deformations that are not shown with strong contrast in the 2D image. In this paper, we present a method for recognizing surface defects in 3D point clouds. Firstly, we propose a novel 3D local descriptor called the Model Point Feature Histogram (MPFH) for defect detection. Our descriptor is inspired from earlier descriptors such as the Point Feature Histogram (PFH). To construct the MPFH descriptor, the models that best fit the local surface and their normal vectors are estimated. For each surface model, its contribution weight to the formation of the surface region is calculated and from the relative difference between models of the same region a histogram is generated representing the underlying surface changes. Secondly, through a classification stage, the points on the surface are labeled according to five types of primitives and the defect is detected. Thirdly, the connected components of primitives are projected to a plane, forming a 2D image. Finally, 2D geometrical features are extracted and by a support vector machine, the defects are recognized. The database used is composed of 3D simulated surfaces and 3D reconstructions of defects in welding, artificial teeth, indentations in materials, ceramics and 3D models of defects. The quantitative and qualitative results showed that the proposed method of description is robust to noise and the scale factor, and it is sufficiently discriminative for detecting some surface defects. The performance evaluation of the proposed method was performed for a classification task of the 3D point cloud in primitives, reporting an accuracy of 95%, which is higher than for other state-of-art descriptors. The rate of recognition of defects was close to 94%.
A Method for Automatic Surface Inspection Using a Model-Based 3D Descriptor
Branch, John W.
2017-01-01
Automatic visual inspection allows for the identification of surface defects in manufactured parts. Nevertheless, when defects are on a sub-millimeter scale, detection and recognition are a challenge. This is particularly true when the defect generates topological deformations that are not shown with strong contrast in the 2D image. In this paper, we present a method for recognizing surface defects in 3D point clouds. Firstly, we propose a novel 3D local descriptor called the Model Point Feature Histogram (MPFH) for defect detection. Our descriptor is inspired from earlier descriptors such as the Point Feature Histogram (PFH). To construct the MPFH descriptor, the models that best fit the local surface and their normal vectors are estimated. For each surface model, its contribution weight to the formation of the surface region is calculated and from the relative difference between models of the same region a histogram is generated representing the underlying surface changes. Secondly, through a classification stage, the points on the surface are labeled according to five types of primitives and the defect is detected. Thirdly, the connected components of primitives are projected to a plane, forming a 2D image. Finally, 2D geometrical features are extracted and by a support vector machine, the defects are recognized. The database used is composed of 3D simulated surfaces and 3D reconstructions of defects in welding, artificial teeth, indentations in materials, ceramics and 3D models of defects. The quantitative and qualitative results showed that the proposed method of description is robust to noise and the scale factor, and it is sufficiently discriminative for detecting some surface defects. The performance evaluation of the proposed method was performed for a classification task of the 3D point cloud in primitives, reporting an accuracy of 95%, which is higher than for other state-of-art descriptors. The rate of recognition of defects was close to 94%. PMID:28974037
Ultrasound pallet part evaluator/grader and cant scanner
Mohammed F. Kabir; Philip A. Araman; Daniel L. Schmoldt; Mark E. Schafer
2002-01-01
Sorting and grading of wooden pallet parts are key factors for manufacturing quality and durable pallets. The feasibility of ultrasonic scanning for defect detection and classification has been examined in this report. Defects, such as sound and unsound knots, decay, bark pockets, wane, and holes were scanned on both red oak (Quercus rubra, L.) and yellow-poplar (...
Developing a database management system to support birth defects surveillance in Florida.
Salemi, Jason L; Hauser, Kimberlea W; Tanner, Jean Paul; Sampat, Diana; Correia, Jane A; Watkins, Sharon M; Kirby, Russell S
2010-01-01
The value of any public health surveillance program is derived from the ways in which data are managed and used to improve the public's health. Although birth defects surveillance programs vary in their case volume, budgets, staff, and objectives, the capacity to operate efficiently and maximize resources remains critical to long-term survival. The development of a fully-integrated relational database management system (DBMS) can enrich a surveillance program's data and improve efficiency. To build upon the Florida Birth Defects Registry--a statewide registry relying solely on linkage of administrative datasets and unconfirmed diagnosis codes-the Florida Department of Health provided funding to the University of South Florida to develop and pilot an enhanced surveillance system in targeted areas with a more comprehensive approach to case identification and diagnosis confirmation. To manage operational and administrative complexities, a DBMS was developed, capable of managing transmission of project data from multiple sources, tracking abstractor time during record reviews, offering tools for defect coding and case classification, and providing reports to DBMS users. Since its inception, the DBMS has been used as part of our surveillance projects to guide the receipt of over 200 case lists and review of 12,924 fetuses and infants (with associated maternal records) suspected of having selected birth defects in over 90 birthing and transfer facilities in Florida. The DBMS has provided both anticipated and unexpected benefits. Automation of the processes for managing incoming case lists has reduced clerical workload considerably, while improving accuracy of working lists for field abstraction. Data quality has improved through more effective use of internal edits and comparisons with values for other data elements, while simultaneously increasing abstractor efficiency in completion of case abstraction. We anticipate continual enhancement to the DBMS in the future. While we have focused on enhancing the capacity of our DBMS for birth defects surveillance, many of the tools and approaches we have developed translate directly to other public health and clinical registries.
McTrusty, Alice D; Cameron, Lorraine A; Perperidis, Antonios; Brash, Harry M; Tatham, Andrew J; Agarwal, Pankaj K; Murray, Ian C; Fleck, Brian W; Minns, Robert A
2017-09-01
We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by masked graders as: 0, normal; 1, paracentral defect; 2, nasal step; 3, arcuate defect; 4, altitudinal; 5, biarcuate; and 6, end-stage field loss. SVOP and SAP classifications were cross-tabulated. Subjects completed a questionnaire on their opinions of each test. We analyzed 142 (v1) and 111 (v2) SVOP and SAP test pairs. SVOP v2 had a sensitivity of 97.7% and specificity of 77.9% for identifying normal versus abnormal visual fields. SAP and SVOP v2 classifications showed complete agreement in 54% of glaucoma patients, with a further 23% disagreeing by one category. On repeat testing, 86% of SVOP v2 classifications agreed with the previous test, compared to 91% of SAP classifications; 71% of subjects preferred SVOP compared to 20% who preferred SAP. Eye-tracking perimetry can be used to obtain threshold visual field sensitivity values in patients with glaucoma and produce maps of visual field defects, with patterns exhibiting close agreement to SAP. Patients preferred eye-tracking perimetry compared to SAP. This first report of threshold eye tracking perimetry shows good agreement with conventional automated perimetry and provides a benchmark for future iterations.
Yang, Yun-fa; Xu, Zhong-he; Zhang, Guang-ming; Wang, Jian-wei; Hu, Si-wang; Hou, Zhi-qi; Xu, Da-chuan
2013-11-01
Posttraumatic infected massive bone defects in lower extremities are difficult to repair because they frequently exhibit massive bone and/or soft tissue defects, serious bone infection, and excessive scar proliferation. This study aimed to determine whether these defects could be classified and repaired at a single stage. A total of 51 cases of posttraumatic infected massive bone defect in lower extremity were included in this study. They were classified into four types on the basis of the conditions of the bone defects, soft tissue defects, and injured limb length, including Type A (without soft tissue defects), Type B (with soft tissue defects of 10 × 20 cm or less), Type C (with soft tissue defects of 10 × 20 cm or more), and Type D (with the limb shortening of 3 cm or more). Four types of single-stage microsurgical repair protocols were planned accordingly and implemented respectively. These protocols included the following: Protocol A, where vascularized fibular graft was implemented for Type A; Protocol B, where vascularized fibular osteoseptocutaneous graft was implemented for Type B; Protocol C, where vascularized fibular graft and anterior lateral thigh flap were used for Type C; and Protocol D, where limb lengthening and Protocols A, B, or C were used for Type D. There were 12, 33, 4, and 2 cases of Types A, B, C, and D, respectively, according to this classification. During the surgery, three cases of planned Protocol B had to be shifted into Protocol C; however, all microsurgical repairs were completed. With reference to Johner-Wruhs evaluation method, the total percentage of excellent and good results was 82.35% after 6 to 41 months of follow-up. It was concluded that posttraumatic massive bone defects could be accurately classified into four types on the basis of the conditions of bone defects, soft tissue coverage, and injured limb length, and successfully repaired with the single-stage repair protocols after thorough debridement. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Imaging of juvenile idiopathic arthritis. Part I: Clinical classifications and radiographs
Matuszewska, Genowefa; Gietka, Piotr; Płaza, Mateusz; Walentowska-Janowicz, Marta
2016-01-01
Juvenile idiopathic arthritis is the most common autoimmune systemic disease of the connective tissue affecting individuals at the developmental age. Radiography is the primary modality employed in the diagnostic imaging in order to identify changes typical of this disease entity and rule out other bone-related pathologies, such as neoplasms, posttraumatic changes, developmental defects and other forms of arthritis. The standard procedure involves the performance of comparative joint radiographs in two planes. Radiographic changes in juvenile idiopathic arthritis are detected in later stages of the disease. Bone structures are assessed in the first place. Radiographs can also indirectly indicate the presence of soft tissue inflammation (i.e. in joint cavities, sheaths and bursae) based on swelling and increased density of the soft tissue as well as dislocation of fat folds. Signs of articular cartilage defects are also seen in radiographs indirectly – based on joint space width changes. The first part of the publication presents the classification of juvenile idiopathic arthritis and discusses its radiographic images. The authors list the affected joints as well as explain the spectrum and specificity of radiographic signs resulting from inflammatory changes overlapping with those caused by the maturation of the skeletal system. Moreover, certain dilemmas associated with the monitoring of the disease are reviewed. The second part of the publication will explain issues associated with ultrasonography and magnetic resonance imaging, which are more and more commonly applied in juvenile idiopathic arthritis for early detection of pathological features as well as the disease complications. PMID:27679726
Automatic Detection of Welding Defects using Deep Neural Network
NASA Astrophysics Data System (ADS)
Hou, Wenhui; Wei, Ye; Guo, Jie; Jin, Yi; Zhu, Chang'an
2018-01-01
In this paper, we propose an automatic detection schema including three stages for weld defects in x-ray images. Firstly, the preprocessing procedure for the image is implemented to locate the weld region; Then a classification model which is trained and tested by the patches cropped from x-ray images is constructed based on deep neural network. And this model can learn the intrinsic feature of images without extra calculation; Finally, the sliding-window approach is utilized to detect the whole images based on the trained model. In order to evaluate the performance of the model, we carry out several experiments. The results demonstrate that the classification model we proposed is effective in the detection of welded joints quality.
Wood texture classification by fuzzy neural networks
NASA Astrophysics Data System (ADS)
Gonzaga, Adilson; de Franca, Celso A.; Frere, Annie F.
1999-03-01
The majority of scientific papers focusing on wood classification for pencil manufacturing take into account defects and visual appearance. Traditional methodologies are base don texture analysis by co-occurrence matrix, by image modeling, or by tonal measures over the plate surface. In this work, we propose to classify plates of wood without biological defects like insect holes, nodes, and cracks, by analyzing their texture. By this methodology we divide the plate image in several rectangular windows or local areas and reduce the number of gray levels. From each local area, we compute the histogram of difference sand extract texture features, given them as input to a Local Neuro-Fuzzy Network. Those features are from the histogram of differences instead of the image pixels due to their better performance and illumination independence. Among several features like media, contrast, second moment, entropy, and IDN, the last three ones have showed better results for network training. Each LNN output is taken as input to a Partial Neuro-Fuzzy Network (PNFN) classifying a pencil region on the plate. At last, the outputs from the PNFN are taken as input to a Global Fuzzy Logic doing the plate classification. Each pencil classification within the plate is done taking into account each quality index.
Defect-Engineered Metal–Organic Frameworks
Fang, Zhenlan; Bueken, Bart; De Vos, Dirk E; Fischer, Roland A
2015-01-01
Defect engineering in metal–organic frameworks (MOFs) is an exciting concept for tailoring material properties, which opens up novel opportunities not only in sorption and catalysis, but also in controlling more challenging physical characteristics such as band gap as well as magnetic and electrical/conductive properties. It is challenging to structurally characterize the inherent or intentionally created defects of various types, and there have so far been few efforts to comprehensively discuss these issues. Based on selected reports spanning the last decades, this Review closes that gap by providing both a concise overview of defects in MOFs, or more broadly coordination network compounds (CNCs), including their classification and characterization, together with the (potential) applications of defective CNCs/MOFs. Moreover, we will highlight important aspects of “defect-engineering” concepts applied for CNCs, also in comparison with relevant solid materials such as zeolites or COFs. Finally, we discuss the future potential of defect-engineered CNCs. PMID:26036179
Feature extraction in MFL signals of machined defects in steel tubes
NASA Astrophysics Data System (ADS)
Perazzo, R.; Pignotti, A.; Reich, S.; Stickar, P.
2001-04-01
Thirty defects of various shapes were machined on the external and internal wall surfaces of a 177 mm diameter ferromagnetic steel pipe. MFL signals were digitized and recorded at a frequency of 4 Khz. Various magnetizing currents and relative tube-probe velocities of the order of 2m/s were used. The identification of the location of the defect by a principal component/neural network analysis of the signal is shown to be more effective than the standard procedure of classification based on the average signal frequency.
NASA Astrophysics Data System (ADS)
Linares, Rodrigo; Vergara, German; Gutiérrez, Raúl; Fernández, Carlos; Villamayor, Víctor; Gómez, Luis; González-Camino, Maria; Baldasano, Arturo; Castro, G.; Arias, R.; Lapido, Y.; Rodríguez, J.; Romero, Pablo
2015-05-01
The combination of flexibility, productivity, precision and zero-defect manufacturing in future laser-based equipment are a major challenge that faces this enabling technology. New sensors for online monitoring and real-time control of laserbased processes are necessary for improving products quality and increasing manufacture yields. New approaches to fully automate processes towards zero-defect manufacturing demand smarter heads where lasers, optics, actuators, sensors and electronics will be integrated in a unique compact and affordable device. Many defects arising in laser-based manufacturing processes come from instabilities in the dynamics of the laser process. Temperature and heat dynamics are key parameters to be monitored. Low cost infrared imagers with high-speed of response will constitute the next generation of sensors to be implemented in future monitoring and control systems for laser-based processes, capable to provide simultaneous information about heat dynamics and spatial distribution. This work describes the result of using an innovative low-cost high-speed infrared imager based on the first quantum infrared imager monolithically integrated with Si-CMOS ROIC of the market. The sensor is able to provide low resolution images at frame rates up to 10 KHz in uncooled operation at the same cost as traditional infrared spot detectors. In order to demonstrate the capabilities of the new sensor technology, a low-cost camera was assembled on a standard production laser welding head, allowing to register melting pool images at frame rates of 10 kHz. In addition, a specific software was developed for defect detection and classification. Multiple laser welding processes were recorded with the aim to study the performance of the system and its application to the real-time monitoring of laser welding processes. During the experiments, different types of defects were produced and monitored. The classifier was fed with the experimental images obtained. Self-learning strategies were implemented with very promising results, demonstrating the feasibility of using low-cost high-speed infrared imagers in advancing towards a real-time / in-line zero-defect production systems.
Automatic classification of DMSA scans using an artificial neural network
NASA Astrophysics Data System (ADS)
Wright, J. W.; Duguid, R.; Mckiddie, F.; Staff, R. T.
2014-04-01
DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA scans as positive or negative for defects using a representative sample of 257 previously reported images. The trained network was then independently tested using a further 193 scans and achieved a binary classification accuracy of 95.9%. The performance of the network was compared with three qualified expert observers who were asked to grade each scan in the 193 image testing set on a six point defect scale, from ‘definitely normal’ to ‘definitely abnormal’. A receiver operating characteristic analysis comparison between a consensus operator, generated from the scores of the three expert observers, and the network revealed a statistically significant increase (α < 0.05) in performance between the network and operators. A further result from this work was that when suitably optimized, a negative predictive value of 100% for renal defects was achieved by the network, while still managing to identify 93% of the negative cases in the dataset. These results are encouraging for application of such a network as a screening tool or quality assurance assistant in clinical practice.
[Reconstruction of tangential and circular infected bone defects].
Schmidt, H G; Neikes, M; Zimmer, W
1987-12-01
In the treatment of bone infections the reconstruction and rehabilitation of bone defects is a problem that often requires treatment secondary to curative treatment of the infection. For the reconstruction of smaller and more extensive defects we used predominantly (92.7%) autogenous (autologous) untreated spongiosa and in only 7% of the cases allogenic (homologous) spongiosa from an organ bank, this being added if necessary. Recently the additionally introduced vascularized bone chip has become a useful extension of the therapy concept. The problems and complications of defect reconstruction are demonstrated for 705 cases of bone infection with 472 defects of different sizes, based on a comprehensive classification with defect calculation. Surgical technical approach and special aspects of after-treatment are described, as well as the results for every group of cases. We achieved stability and freedom from infection in a total of 93.7% of the patients. As was to be expected, the problems grow with the size of the defect. Particularly problematic are joint infections with adjacent extensive circular defect.
Yu, Xiao; Ding, Enjie; Chen, Chunxu; Liu, Xiaoming; Li, Li
2015-01-01
Because roller element bearings (REBs) failures cause unexpected machinery breakdowns, their fault diagnosis has attracted considerable research attention. Established fault feature extraction methods focus on statistical characteristics of the vibration signal, which is an approach that loses sight of the continuous waveform features. Considering this weakness, this article proposes a novel feature extraction method for frequency bands, named Window Marginal Spectrum Clustering (WMSC) to select salient features from the marginal spectrum of vibration signals by Hilbert–Huang Transform (HHT). In WMSC, a sliding window is used to divide an entire HHT marginal spectrum (HMS) into window spectrums, following which Rand Index (RI) criterion of clustering method is used to evaluate each window. The windows returning higher RI values are selected to construct characteristic frequency bands (CFBs). Next, a hybrid REBs fault diagnosis is constructed, termed by its elements, HHT-WMSC-SVM (support vector machines). The effectiveness of HHT-WMSC-SVM is validated by running series of experiments on REBs defect datasets from the Bearing Data Center of Case Western Reserve University (CWRU). The said test results evidence three major advantages of the novel method. First, the fault classification accuracy of the HHT-WMSC-SVM model is higher than that of HHT-SVM and ST-SVM, which is a method that combines statistical characteristics with SVM. Second, with Gauss white noise added to the original REBs defect dataset, the HHT-WMSC-SVM model maintains high classification accuracy, while the classification accuracy of ST-SVM and HHT-SVM models are significantly reduced. Third, fault classification accuracy by HHT-WMSC-SVM can exceed 95% under a Pmin range of 500–800 and a m range of 50–300 for REBs defect dataset, adding Gauss white noise at Signal Noise Ratio (SNR) = 5. Experimental results indicate that the proposed WMSC method yields a high REBs fault classification accuracy and a good performance in Gauss white noise reduction. PMID:26540059
Yu, Xiao; Ding, Enjie; Chen, Chunxu; Liu, Xiaoming; Li, Li
2015-11-03
Because roller element bearings (REBs) failures cause unexpected machinery breakdowns, their fault diagnosis has attracted considerable research attention. Established fault feature extraction methods focus on statistical characteristics of the vibration signal, which is an approach that loses sight of the continuous waveform features. Considering this weakness, this article proposes a novel feature extraction method for frequency bands, named Window Marginal Spectrum Clustering (WMSC) to select salient features from the marginal spectrum of vibration signals by Hilbert-Huang Transform (HHT). In WMSC, a sliding window is used to divide an entire HHT marginal spectrum (HMS) into window spectrums, following which Rand Index (RI) criterion of clustering method is used to evaluate each window. The windows returning higher RI values are selected to construct characteristic frequency bands (CFBs). Next, a hybrid REBs fault diagnosis is constructed, termed by its elements, HHT-WMSC-SVM (support vector machines). The effectiveness of HHT-WMSC-SVM is validated by running series of experiments on REBs defect datasets from the Bearing Data Center of Case Western Reserve University (CWRU). The said test results evidence three major advantages of the novel method. First, the fault classification accuracy of the HHT-WMSC-SVM model is higher than that of HHT-SVM and ST-SVM, which is a method that combines statistical characteristics with SVM. Second, with Gauss white noise added to the original REBs defect dataset, the HHT-WMSC-SVM model maintains high classification accuracy, while the classification accuracy of ST-SVM and HHT-SVM models are significantly reduced. Third, fault classification accuracy by HHT-WMSC-SVM can exceed 95% under a Pmin range of 500-800 and a m range of 50-300 for REBs defect dataset, adding Gauss white noise at Signal Noise Ratio (SNR) = 5. Experimental results indicate that the proposed WMSC method yields a high REBs fault classification accuracy and a good performance in Gauss white noise reduction.
Studying post-etching silicon crystal defects on 300mm wafer by automatic defect review AFM
NASA Astrophysics Data System (ADS)
Zandiatashbar, Ardavan; Taylor, Patrick A.; Kim, Byong; Yoo, Young-kook; Lee, Keibock; Jo, Ahjin; Lee, Ju Suk; Cho, Sang-Joon; Park, Sang-il
2016-03-01
Single crystal silicon wafers are the fundamental elements of semiconductor manufacturing industry. The wafers produced by Czochralski (CZ) process are very high quality single crystalline materials with known defects that are formed during the crystal growth or modified by further processing. While defects can be unfavorable for yield for some manufactured electrical devices, a group of defects like oxide precipitates can have both positive and negative impacts on the final device. The spatial distribution of these defects may be found by scattering techniques. However, due to limitations of scattering (i.e. light wavelength), many crystal defects are either poorly classified or not detected. Therefore a high throughput and accurate characterization of their shape and dimension is essential for reviewing the defects and proper classification. While scanning electron microscopy (SEM) can provide high resolution twodimensional images, atomic force microscopy (AFM) is essential for obtaining three-dimensional information of the defects of interest (DOI) as it is known to provide the highest vertical resolution among all techniques [1]. However AFM's low throughput, limited tip life, and laborious efforts for locating the DOI have been the limitations of this technique for defect review for 300 mm wafers. To address these limitations of AFM, automatic defect review AFM has been introduced recently [2], and is utilized in this work for studying DOI on 300 mm silicon wafer. In this work, we carefully etched a 300 mm silicon wafer with a gaseous acid in a reducing atmosphere at a temperature and for a sufficient duration to decorate and grow the crystal defects to a size capable of being detected as light scattering defects [3]. The etched defects form a shallow structure and their distribution and relative size are inspected by laser light scattering (LLS). However, several groups of defects couldn't be properly sized by the LLS due to the very shallow depth and low light scattering. Likewise, SEM cannot be used effectively for post-inspection defect review and classification of these very shallow types of defects. To verify and obtain accurate shape and three-dimensional information of those defects, automatic defect review AFM (ADR AFM) is utilized for accurate locating and imaging of DOI. In ADR AFM, non-contact mode imaging is used for non-destructive characterization and preserving tip sharpness for data repeatability and reproducibility. Locating DOI and imaging are performed automatically with a throughput of many defects per hour. Topography images of DOI has been collected and compared with SEM images. The ADR AFM has been shown as a non-destructive metrology tool for defect review and obtaining three-dimensional topography information.
A definitional framework for the human/biometric sensor interaction model
NASA Astrophysics Data System (ADS)
Elliott, Stephen J.; Kukula, Eric P.
2010-04-01
Existing definitions for biometric testing and evaluation do not fully explain errors in a biometric system. This paper provides a definitional framework for the Human Biometric-Sensor Interaction (HBSI) model. This paper proposes six new definitions based around two classifications of presentations, erroneous and correct. The new terms are: defective interaction (DI), concealed interaction (CI), false interaction (FI), failure to detect (FTD), failure to extract (FTX), and successfully acquired samples (SAS). As with all definitions, the new terms require a modification to the general biometric model developed by Mansfield and Wayman [1].
Eisenmenger ventricular septal defect in a Humboldt penguin (Spheniscus humboldti).
Laughlin, D S; Ialeggio, D M; Trupkiewicz, J G; Sleeper, M M
2016-09-01
The Eisenmenger ventricular septal defect is an uncommon type of ventricular septal defect characterised in humans by a traditionally perimembranous ventricular septal defect, anterior deviation (cranioventral deviation in small animal patients) of the muscular outlet septum causing malalignment relative to the remainder of the muscular septum, and overriding of the aortic valve. This anomaly is reported infrequently in human patients and was identified in a 45-day-old Humboldt Penguin, Spheniscus humboldti, with signs of poor growth and a cardiac murmur. This case report describes the findings in this penguin and summarises the anatomy and classification of this cardiac anomaly. To the authors' knowledge this is the first report of an Eisenmenger ventricular septal defect in a veterinary patient. Copyright © 2016 Elsevier B.V. All rights reserved.
Atomistic and Ab Initio Calculations or Ternary II-IV-V2 Semiconductors
1999-12-07
consisting of two- and three-body terms is developed reproducing crystal lattice constants, elastic and dielectric constants very well. The calculated...the lattice . This difference may well be due to defect-induced lattice distortion which plays a key role in stabilizing the hole states in the... lattice . 15. SUBJECT TERMS Chalcopyrites, Defects, Atomistic and AB Initio Calculations 16. SECURITY CLASSIFICATION OF: a. REPORT u b. ABSTRACT U
[Acquired disorders of color vision].
Lascu, Lidia; Balaş, Mihaela
2002-01-01
This article is a general view of acquired disorders of color vision. The revision of the best known methods and of the etiopathogenic classification is not very important in ophthalmology but on the other hand, the detection of the blue defect advertise and associated ocular pathology. There is a major interest in serious diseases as multiple sclerosis, AIDS, diabetes melitus, when the first ocular sign can be a defect in the color vision.
[Difficulties of the methods for studying environmental exposure and neural tube defects].
Borja-Aburto, V H; Bermúdez-Castro, O; Lacasaña-Navarro, M; Kuri, P; Bustamante-Montes, P; Torres-Meza, V
1999-01-01
To discuss the attitudes in the assessment of environmental exposures as risk factors associated with neural tube defects, and to present the main risk factors studied to date. Environmental exposures have been suggested to have a roll in the genesis of birth defects. However, studies conducted in human populations have found difficulties in the design and conduction to show such an association for neural tube defects (anencephaly, espina bifida and encephalocele) because of problems raised from: a) the frequency measures used to compare time trends and communities, b) the classification of heterogeneous malformations, c) the inclusion of maternal, paternal and fetal factors as an integrated process and, d) the assessment of environmental exposures. Hypothetically both maternal and paternal environmental exposures can produce damage before and after conception by direct action on the embryo and the fetus-placenta complex. Therefore, in the assessment of environmental exposures we need to take into account: a) both paternal and maternal exposures; b) the critical exposure period, three months before conception for paternal exposures and one month around the conceptional period for maternal exposures; c) quantitatively evaluate environmental exposures when possible, avoiding a dichotomous classification; d) the use of biological markers of exposure is highly recommended as well as markers of genetic susceptibility.
An investigation on defect-generation conditions in immersion lithography
NASA Astrophysics Data System (ADS)
Tomita, Tadatoshi; Shimoaoki, Takeshi; Enomoto, Masashi; Kyoda, Hideharu; Kitano, Junichi; Suganaga, Toshifumi
2006-03-01
As a powerful candidate for a lithography technique that can accommodate the scaling-down of semiconductors, 193-nm immersion lithography-which realizes a high numerical aperture (NA) and uses deionized water as the medium between the lens and wafer in the exposure system-has been developing at a rapid pace and has reached the stage of practical application. In regards to defects that are a cause for concern in the case of 193-nm immersion lithography, however, many components are still unclear and many problems remain to be solved. It has been pointed out, for example, that in the case of 193-nm immersion lithography, immersion of the resist film in deionized water during exposure causes infiltration of moisture into the resist film, internal components of the resist dissolve into the deionized water, and residual water generated during exposure affects post-processing. Moreover, to prevent this influence of directly immersing the resist in de-ionized water, application of a protective film is regarded as effective. However, even if such a film is applied, it is still highly likely that the above-mentioned defects will still occur. Accordingly, to reduce these defects, it is essential to identify the typical defects occurring in 193-nm immersion lithography and to understand the condition for generation of defects by using some kinds of protective films and resist materials. Furthermore, from now onwards, with further scaling down of semiconductors, it is important to maintain a clear understanding of the relation between defect-generation conditions and critical dimensions (CD). Aiming to extract typical defects occurring in 193-nm immersion lithography, the authors carried out a comparative study with dry exposure lithography, thereby confirming several typical defects associated with immersion lithography. We then investigated the conditions for generation of defects in the case of some kinds of protective films. In addition to that, by investigating the defect-generation conditions and comparing the classification data between wet and dry exposure, we were able to determine the origin of each particular defect involved in immersion lithography. Furthermore, the comparison of CD for wet and dry processing could indicate the future defectivity levels to be expected with shrinking immersion process critical dimensions.
Machine learning vortices at the Kosterlitz-Thouless transition
NASA Astrophysics Data System (ADS)
Beach, Matthew J. S.; Golubeva, Anna; Melko, Roger G.
2018-01-01
Efficient and automated classification of phases from minimally processed data is one goal of machine learning in condensed-matter and statistical physics. Supervised algorithms trained on raw samples of microstates can successfully detect conventional phase transitions via learning a bulk feature such as an order parameter. In this paper, we investigate whether neural networks can learn to classify phases based on topological defects. We address this question on the two-dimensional classical XY model which exhibits a Kosterlitz-Thouless transition. We find significant feature engineering of the raw spin states is required to convincingly claim that features of the vortex configurations are responsible for learning the transition temperature. We further show a single-layer network does not correctly classify the phases of the XY model, while a convolutional network easily performs classification by learning the global magnetization. Finally, we design a deep network capable of learning vortices without feature engineering. We demonstrate the detection of vortices does not necessarily result in the best classification accuracy, especially for lattices of less than approximately 1000 spins. For larger systems, it remains a difficult task to learn vortices.
Legal and medical aspects of body dysmorphic disorder.
Nachshoni, Tali; Kotler, Moshe
2007-12-01
Body Dysmorphic Disorder (BDD), a preoccupation with an imagined defect in physical appearance has a rich clinical history, but officially appeared with diagnostic criteria only in the DSM-III-R classification system. Prevalence of BDD in plastic and cosmetic dermatology ranges between 7-15% due to the obsession with imagined imperfections. The emotional "defect" causes dissatisfaction with nonpsychiatric medical procedures, and often recourse into legal action. We present a case study of BDD developing after cosmetic surgery and debate whether this is an actual possibility and the legal consequences of this possibility. We question whether surgery was a traumatic event and its relationship to the patient's premorbid "eggshell personality". The difficulty in determining causation of psychiatric disorders for the purpose of deciding issues of compensation is discussed. A practical algorithm is offered in order to avoid litigation and to maintain the legitimate medical ideal of "first do no harm".
A Generic Deep-Learning-Based Approach for Automated Surface Inspection.
Ren, Ruoxu; Hung, Terence; Tan, Kay Chen
2018-03-01
Automated surface inspection (ASI) is a challenging task in industry, as collecting training dataset is usually costly and related methods are highly dataset-dependent. In this paper, a generic approach that requires small training data for ASI is proposed. First, this approach builds classifier on the features of image patches, where the features are transferred from a pretrained deep learning network. Next, pixel-wise prediction is obtained by convolving the trained classifier over input image. An experiment on three public and one industrial data set is carried out. The experiment involves two tasks: 1) image classification and 2) defect segmentation. The results of proposed algorithm are compared against several best benchmarks in literature. In the classification tasks, the proposed method improves accuracy by 0.66%-25.50%. In the segmentation tasks, the proposed method reduces error escape rates by 6.00%-19.00% in three defect types and improves accuracies by 2.29%-9.86% in all seven defect types. In addition, the proposed method achieves 0.0% error escape rate in the segmentation task of industrial data.
NASA Astrophysics Data System (ADS)
Castaneda-Lopez, Homero
A methodology for detecting and locating defects or discontinuities on the outside covering of coated metal underground pipelines subjected to cathodic protection has been addressed. On the basis of wide range AC impedance signals for various frequencies applied to a steel-coated pipeline system and by measuring its corresponding transfer function under several laboratory simulation scenarios, a physical laboratory setup of an underground cathodic-protected, coated pipeline was built. This model included different variables and elements that exist under real conditions, such as soil resistivity, soil chemical composition, defect (holiday) location in the pipeline covering, defect area and geometry, and level of cathodic protection. The AC impedance data obtained under different working conditions were used to fit an electrical transmission line model. This model was then used as a tool to fit the impedance signal for different experimental conditions and to establish trends in the impedance behavior without the necessity of further experimental work. However, due to the chaotic nature of the transfer function response of this system under several conditions, it is believed that non-deterministic models based on pattern recognition algorithms are suitable for field condition analysis. A non-deterministic approach was used for experimental analysis by applying an artificial neural network (ANN) algorithm based on classification analysis capable of studying the pipeline system and differentiating the variables that can change impedance conditions. These variables include level of cathodic protection, location of discontinuities (holidays), and severity of corrosion. This work demonstrated a proof-of-concept for a well-known technique and a novel algorithm capable of classifying impedance data for experimental results to predict the exact location of the active holidays and defects on the buried pipelines. Laboratory findings from this procedure are promising, and efforts to develop it for field conditions should continue.
Huang, Tao; Li, Xiao-yu; Jin, Rui; Ku, Jing; Xu, Sen-miao; Xu, Meng-ling; Wu, Zhen-zhong; Kong, De-guo
2015-04-01
The present paper put forward a non-destructive detection method which combines semi-transmission hyperspectral imaging technology with manifold learning dimension reduction algorithm and least squares support vector machine (LSSVM) to recognize internal and external defects in potatoes simultaneously. Three hundred fifteen potatoes were bought in farmers market as research object, and semi-transmission hyperspectral image acquisition system was constructed to acquire the hyperspectral images of normal external defects (bud and green rind) and internal defect (hollow heart) potatoes. In order to conform to the actual production, defect part is randomly put right, side and back to the acquisition probe when the hyperspectral images of external defects potatoes are acquired. The average spectrums (390-1,040 nm) were extracted from the region of interests for spectral preprocessing. Then three kinds of manifold learning algorithm were respectively utilized to reduce the dimension of spectrum data, including supervised locally linear embedding (SLLE), locally linear embedding (LLE) and isometric mapping (ISOMAP), the low-dimensional data gotten by manifold learning algorithms is used as model input, Error Correcting Output Code (ECOC) and LSSVM were combined to develop the multi-target classification model. By comparing and analyzing results of the three models, we concluded that SLLE is the optimal manifold learning dimension reduction algorithm, and the SLLE-LSSVM model is determined to get the best recognition rate for recognizing internal and external defects potatoes. For test set data, the single recognition rate of normal, bud, green rind and hollow heart potato reached 96.83%, 86.96%, 86.96% and 95% respectively, and he hybrid recognition rate was 93.02%. The results indicate that combining the semi-transmission hyperspectral imaging technology with SLLE-LSSVM is a feasible qualitative analytical method which can simultaneously recognize the internal and external defects potatoes and also provide technical reference for rapid on-line non-destructive detecting of the internal and external defects potatoes.
Cosgrove, Casey M; Tritchler, David L; Cohn, David E; Mutch, David G; Rush, Craig M; Lankes, Heather A; Creasman, William T.; Miller, David S; Ramirez, Nilsa C; Geller, Melissa A; Powell, Matthew A; Backes, Floor J; Landrum, Lisa M; Timmers, Cynthia; Suarez, Adrian A; Zaino, Richard J; Pearl, Michael L; DiSilvestro, Paul A; Lele, Shashikant B; Goodfellow, Paul J
2017-01-01
Objectives The purpose of this study was to assess the prognostic significance of a simplified, clinically accessible classification system for endometrioid endometrial cancers combining Lynch syndrome screening and molecular risk stratification. Methods Tumors from NRG/GOG GOG210 were evaluated for mismatch repair defects (MSI, MMR IHC, and MLH1 methylation), POLE mutations, and loss of heterozygosity. TP53 was evaluated in a subset of cases. Tumors were assigned to four molecular classes. Relationships between molecular classes and clinicopathologic variables were assessed using contingency tests and Cox proportional methods. Results Molecular classification was successful for 982 tumors. Based on the NCI consensus MSI panel assessing MSI and loss of heterozygosity combined with POLE testing, 49% of tumors were classified copy number stable (CNS), 39% MMR deficient, 8% copy number altered (CNA) and 4% POLE mutant. Cancer-specific mortality occurred in 5% of patients with CNS tumors; 2.6% with POLE tumors; 7.6% with MMR deficient tumors and 19% with CNA tumors. The CNA group had worse progression-free (HR 2.31, 95%CI 1.53–3.49) and cancer-specific survival (HR 3.95; 95%CI 2.10–7.44). The POLE group had improved outcomes, but the differences were not statistically significant. CNA class remained significant for cancer-specific survival (HR 2.11; 95%CI 1.04–4.26) in multivariable analysis. The CNA molecular class was associated with TP53 mutation and expression status. Conclusions A simple molecular classification for endometrioid endometrial cancers that can be easily combined with Lynch syndrome screening provides important prognostic information. These findings support prospective clinical validation and further studies on the predictive value of a simplified molecular classification system. PMID:29132872
Perception of olive oils sensory defects using a potentiometric taste device.
Veloso, Ana C A; Silva, Lucas M; Rodrigues, Nuno; Rebello, Ligia P G; Dias, Luís G; Pereira, José A; Peres, António M
2018-01-01
The capability of perceiving olive oils sensory defects and intensities plays a key role on olive oils quality grade classification since olive oils can only be classified as extra-virgin if no defect can be perceived by a human trained sensory panel. Otherwise, olive oils may be classified as virgin or lampante depending on the median intensity of the defect predominantly perceived and on the physicochemical levels. However, sensory analysis is time-consuming and requires an official sensory panel, which can only evaluate a low number of samples per day. In this work, the potential use of an electronic tongue as a taste sensor device to identify the defect predominantly perceived in olive oils was evaluated. The potentiometric profiles recorded showed that intra- and inter-day signal drifts could be neglected (i.e., relative standard deviations lower than 25%), being not statistically significant the effect of the analysis day on the overall recorded E-tongue sensor fingerprints (P-value = 0.5715, for multivariate analysis of variance using Pillai's trace test), which significantly differ according to the olive oils' sensory defect (P-value = 0.0084, for multivariate analysis of variance using Pillai's trace test). Thus, a linear discriminant model based on 19 potentiometric signal sensors, selected by the simulated annealing algorithm, could be established to correctly predict the olive oil main sensory defect (fusty, rancid, wet-wood or winey-vinegary) with average sensitivity of 75 ± 3% and specificity of 73 ± 4% (repeated K-fold cross-validation variant: 4 folds×10 repeats). Similarly, a linear discriminant model, based on 24 selected sensors, correctly classified 92 ± 3% of the olive oils as virgin or lampante, being an average specificity of 93 ± 3% achieved. The overall satisfactory predictive performances strengthen the feasibility of the developed taste sensor device as a complementary methodology for olive oils' defects analysis and subsequent quality grade classification. Furthermore, the capability of identifying the type of sensory defect of an olive oil may allow establishing helpful insights regarding bad practices of olives or olive oils production, harvesting, transport and storage. Copyright © 2017 Elsevier B.V. All rights reserved.
7 CFR 51.3416 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely... discoloration (Heat Necrosis) Not more than the equivalent of 3 scattered spots 1/8 inch in diameter in a potato...
7 CFR 51.3416 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely... discoloration (Heat Necrosis) Not more than the equivalent of 3 scattered spots 1/8 inch in diameter in a potato...
NASA Astrophysics Data System (ADS)
Balbin, Jessie R.; Hortinela, Carlos C.; Garcia, Ramon G.; Baylon, Sunnycille; Ignacio, Alexander Joshua; Rivera, Marco Antonio; Sebastian, Jaimie
2017-06-01
Pattern recognition of concrete surface crack defects is very important in determining stability of structure like building, roads or bridges. Surface crack is one of the subjects in inspection, diagnosis, and maintenance as well as life prediction for the safety of the structures. Traditionally determining defects and cracks on concrete surfaces are done manually by inspection. Moreover, any internal defects on the concrete would require destructive testing for detection. The researchers created an automated surface crack detection for concrete using image processing techniques including Hough transform, LoG weighted, Dilation, Grayscale, Canny Edge Detection and Haar Wavelet Transform. An automatic surface crack detection robot is designed to capture the concrete surface by sectoring method. Surface crack classification was done with the use of Haar trained cascade object detector that uses both positive samples and negative samples which proved that it is possible to effectively identify the surface crack defects.
Identification of bearing faults using time domain zero-crossings
NASA Astrophysics Data System (ADS)
William, P. E.; Hoffman, M. W.
2011-11-01
In this paper, zero-crossing characteristic features are employed for early detection and identification of single point bearing defects in rotating machinery. As a result of bearing defects, characteristic defect frequencies appear in the machine vibration signal, normally requiring spectral analysis or envelope analysis to identify the defect type. Zero-crossing features are extracted directly from the time domain vibration signal using only the duration between successive zero-crossing intervals and do not require estimation of the rotational frequency. The features are a time domain representation of the composite vibration signature in the spectral domain. Features are normalized by the length of the observation window and classification is performed using a multilayer feedforward neural network. The model was evaluated on vibration data recorded using an accelerometer mounted on an induction motor housing subjected to a number of single point defects with different severity levels.
Aptel, Florent; Aryal-Charles, Nischal; Tamisier, Renaud; Pépin, Jean-Louis; Lesoin, Antoine; Chiquet, Christophe
2017-06-01
To evaluate whether obstructive sleep apnea (OSA) is responsible for the visual field defects found in the fellow eyes of patients with non-arteritic ischemic optic neuropathy (NAION). Prospective cross-sectional study. The visual fields of the fellow eyes of NAION subjects with OSA were compared to the visual fields of control OSA patients matched for OSA severity. All patients underwent comprehensive ophthalmological and general examination including Humphrey 24.2 SITA-Standard visual field and polysomnography. Visual field defects were classified according the Ischemic Optic Neuropathy Decompression Trial (IONDT) classification. From a cohort of 78 consecutive subjects with NAION, 34 unaffected fellow eyes were compared to 34 control eyes of subjects matched for OSA severity (apnea-hypopnea index [AHI] 35.5 ± 11.6 vs 35.4 ± 9.4 events per hour, respectively, p = 0.63). After adjustment for age and body mass index, all visual field parameters were significantly different between the NAION fellow eyes and those of the control OSA groups, including mean deviation (-4.5 ± 3.7 vs -1.3 ± 1.8 dB, respectively, p < 0.05), visual field index (91.6 ± 10 vs 97.4 ± 3.5%, respectively, p = 0.002), pattern standard deviation (3.7 ± 2.3 vs 2.5 ± 2 dB, respectively, p = 0.015), and number of subjects with at least one defect on the IONDT classification (20 vs 10, respectively, p < 0.05). OSA alone does not explain the visual field defects frequently found in the fellow eyes of NAION patients.
García-Rey, R M; García-Olmo, J; De Pedro, E; Quiles-Zafra, R; Luque de Castro, M D
2005-06-01
The potential of visible and near infrared spectroscopy to predict texture and colour of dry-cured ham samples was investigated. Sensory evaluation was performed on 117 boned and cross-sectioned dry-cured ham samples. Slices of approximate thickness 4cm were cut, vacuum-packaged and kept under frozen storage until spectral analysis. Then, Biceps femoris muscle from the thawed slices was taken and scanned (400-2200nm) using a fiber optic probe. The exploratory analysis using principal component analysis shows that there are two ham groups according to the appearance or not of defects. Then, a K nearest neighbours was used to classify dry-cured hams into defective or no defective classes. The overall accuracy of the classification as a function of pastiness was 88.5%; meanwhile, according to colour was 79.7%. Partial least squares regression was used to formulate prediction equations for pastiness and colour. The correlation coefficients of calibration and cross-validation were 0.97 and 0.86 for optimal equation predicting pastiness, and 0.82 and 0.69 for optimal equation predicting colour. The standard error of cross-validation for predicting pastiness and colour is between 1 and 2 times the standard deviation of the reference method (the error involved in the sensory evaluation by the experts). The magnitude of this error demonstrates the good precision of the methods for predicting pastiness and colour. Furthermore, the samples were classified into defective or no defective classes, with a correct classification of 94.2% according to pasty texture evaluation and 75.7% as regard to colour evaluation.
Automated real-time detection of defects during machining of ceramics
Ellingson, W.A.; Sun, J.
1997-11-18
Apparatus for the automated real-time detection and classification of defects during the machining of ceramic components employs an elastic optical scattering technique using polarized laser light. A ceramic specimen is continuously moved while being machined. Polarized laser light is directed onto the ceramic specimen surface at a fixed position just aft of the machining tool for examination of the newly machined surface. Any foreign material near the location of the laser light on the ceramic specimen is cleared by an air blast. As the specimen is moved, its surface is continuously scanned by the polarized laser light beam to provide a two-dimensional image presented in real-time on a video display unit, with the motion of the ceramic specimen synchronized with the data acquisition speed. By storing known ``feature masks`` representing various surface and sub-surface defects and comparing measured defects with the stored feature masks, detected defects may be automatically characterized. Using multiple detectors, various types of defects may be detected and classified. 14 figs.
Automated real-time detection of defects during machining of ceramics
Ellingson, William A.; Sun, Jiangang
1997-01-01
Apparatus for the automated real-time detection and classification of defects during the machining of ceramic components employs an elastic optical scattering technique using polarized laser light. A ceramic specimen is continuously moved while being machined. Polarized laser light is directed onto the ceramic specimen surface at a fixed position just aft of the machining tool for examination of the newly machined surface. Any foreign material near the location of the laser light on the ceramic specimen is cleared by an air blast. As the specimen is moved, its surface is continuously scanned by the polarized laser light beam to provide a two-dimensional image presented in real-time on a video display unit, with the motion of the ceramic specimen synchronized with the data acquisition speed. By storing known "feature masks" representing various surface and sub-surface defects and comparing measured defects with the stored feature masks, detected defects may be automatically characterized. Using multiple detectors, various types of defects may be detected and classified.
Experience with peroneus brevis muscle flaps for reconstruction of distal leg and ankle defects
Bajantri, Babu; Bharathi, Ravindra; Ramkumar, Sanjai; Latheef, Latheesh; Dhane, Smitha; Sabapathy, S. Raja
2013-01-01
Objective: Peroneus brevis is a muscle in the leg which is expendable without much functional deficit. The objective of this study was to find out its usefulness in coverage of the defects of the lower leg and ankle. Patients and Methods: A retrospective analysis of the use of 39 pedicled peroneus brevis muscle flaps used for coverage of defects of the lower leg and ankle between November 2010 and December 2012 was carried out. The flaps were proximally based for defects of the lower third of the leg in 12 patients and distally based for reconstruction of defects of the ankle in 26 patients, with one patient having flaps on both ankles. Results: Partial flap loss in critical areas was found in four patients requiring further flap cover and in non-critical areas in two patients, which were managed with a skin graft. Three of the four critical losses occurred when we used it for covering defects over the medial malleolus. There was no complete flap loss in any of the patients. Conclusion: This flap has a unique vascular pattern and fails to fit into the classification of the vasculature of muscles by Mathes and Nahai. The unusual feature is an axial vessel system running down the deep aspect of the muscle and linking the perforators from the peroneal artery and anterior tibial artery, which allows it to be raised proximally or distally on a single perforator. The flap is simple to raise and safe for the reconstruction of small-to moderate-sized skin defects of the distal third of the tibia and all parts of the ankle except the medial malleolus, which is too far from the pedicle of the distally based flap. The donor site can be closed primarily to provide a linear scar. The muscle flap thins with time to provide a good result aesthetically at the primary defect. PMID:23960305
Facial clefts and facial dysplasia: revisiting the classification.
Mazzola, Riccardo F; Mazzola, Isabella C
2014-01-01
Most craniofacial malformations are identified by their appearance. The majority of the classification systems are mainly clinical or anatomical, not related to the different levels of development of the malformation, and underlying pathology is usually not taken into consideration. In 1976, Tessier first emphasized the relationship between soft tissues and the underlying bone stating that "a fissure of the soft tissue corresponds, as a general rule, with a cleft of the bony structure". He introduced a cleft numbering system around the orbit from 0 to 14 depending on its relationship to the zero line (ie, the vertical midline cleft of the face). The classification, easy to understand, became widely accepted because the recording of the malformations was simple and communication between observers facilitated. It represented a great breakthrough in identifying craniofacial malformations, named clefts by him. In the present paper, the embryological-based classification of craniofacial malformations, proposed in 1983 and in 1990 by us, has been revisited. Its aim was to clarify some unanswered questions regarding apparently atypical or bizarre anomalies and to establish as much as possible the moment when this event occurred. In our opinion, this classification system may well integrate the one proposed by Tessier and tries at the same time to find a correlation between clinical observation and morphogenesis.Terminology is important. The overused term cleft should be reserved to true clefts only, developed from disturbances in the union of the embryonic facial processes, between the lateronasal and maxillary process (or oro-naso-ocular cleft); between the medionasal and maxillary process (or cleft of the lip); between the maxillary processes (or cleft of the palate); and between the maxillary and mandibular process (or macrostomia).For the other types of defects, derived from alteration of bone production centers, the word dysplasia should be used instead. Facial dysplasias have been ranged in a helix form and named after the site of the developmental arrest. Thus, an internasal, nasal, nasomaxillary, maxillary and malar dysplasia, depending on the involved area, have been identified.The classification may provide a useful guide in better understanding the morphogenesis of rare craniofacial malformations.
Parnell, Aimee S.; Shults, Justine; Gaynor, J. William; Leonard, Mary B.; Dai, Dingwei; Feudtner, Chris
2015-01-01
Background Administrative data is increasingly used to evaluate clinical outcomes and quality of care in pediatric congenital heart surgery (CHS) programs. Several published analyses of large pediatric administrative datasets have relied on the All Patient Refined Diagnosis Related Groups (APR-DRG, version 24) diagnostic classification system. The accuracy of this classification system for patients undergoing CHS is unclear. Methods We performed a retrospective cohort study of all 14,098 patients 0-5 years of age undergoing any of six selected congenital heart operations, ranging in complexity from isolated closure of a ventricular septal defect to single ventricle palliation, at 40 tertiary care pediatric centers in the Pediatric Health Information Systems database between 2007 and 2010. Assigned APR-DRGs (cardiac versus non-cardiac) were compared using chi-squared or Fisher's exact tests between those patients admitted during the first day of life versus later and between those receiving extracorporeal membrane oxygenation support versus not. Recursive partitioning was used to assess the greatest determinants of APR-DRG type in the model. Results Every patient admitted on day of life 1 was assigned to a non-cardiac APR-DRG (p < 0.001 for each procedure). Similarly, use of extracorporeal membrane oxygenation was highly associated with misclassification of congenital heart surgery patients into a non-cardiac APR-DRG (p < 0.001 for each procedure). Cases misclassified into a non-cardiac APR-DRG experienced a significantly increased mortality (p < 0.001). Conclusions In classifying patients undergoing congenital heart surgery, APR-DRG coding has systematic misclassifications, which may result in inaccurate reporting of CHS case volumes and mortality. PMID:24200398
Morphological evaluation of clefts of the lip, palate, or both in dogs.
Peralta, Santiago; Fiani, Nadine; Kan-Rohrer, Kimi H; Verstraete, Frank J M
2017-08-01
OBJECTIVE To systematically characterize the morphology of cleft lip, cleft palate, and cleft lip and palate in dogs. ANIMALS 32 client-owned dogs with clefts of the lip (n = 5), palate (23), or both (4) that had undergone a CT or cone-beam CT scan of the head prior to any surgical procedures involving the oral cavity or face. PROCEDURES Dog signalment and skull type were recorded. The anatomic form of each defect was characterized by use of a widely used human oral-cleft classification system on the basis of CT findings and clinical images. Other defect morphological features, including shape, relative size, facial symmetry, and vomer involvement, were also recorded. RESULTS 9 anatomic forms of cleft were identified. Two anatomic forms were identified in the 23 dogs with cleft palate, in which differences in defect shape and size as well as vomer abnormalities were also evident. Seven anatomic forms were observed in 9 dogs with cleft lip or cleft lip and palate, and most of these dogs had incisive bone abnormalities and facial asymmetry. CONCLUSIONS AND CLINICAL RELEVANCE The morphological features of congenitally acquired cleft lip, cleft palate, and cleft lip and palate were complex and varied among dogs. The features identified here may be useful for surgical planning, developing of clinical coding schemes, or informing genetic, embryological, or clinical research into birth defects in dogs and other species.
7 CFR 51.1877 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 FRESH FRUITS, VEGETABLES AND OTHER PRODUCTS 1,2 (INSPECTION, CERTIFICATION, AND...
Defect reduction of patterned media templates and disks
NASA Astrophysics Data System (ADS)
Luo, Kang; Ha, Steven; Fretwell, John; Ramos, Rick; Ye, Zhengmao; Schmid, Gerard; LaBrake, Dwayne; Resnick, Douglas J.; Sreenivasan, S. V.
2010-05-01
Imprint lithography has been shown to be an effective technique for the replication of nano-scale features. Acceptance of imprint lithography for manufacturing will require a demonstration of defect levels commensurate with cost-effective device production. This work summarizes the results of defect inspections of hard disks patterned using Jet and Flash Imprint Lithography (J-FILTM). Inspections were performed with optical based automated inspection tools. For the hard drive market, it is important to understand the defectivity of both the template and the imprinted disk. This work presents a methodology for automated pattern inspection and defect classification for imprint-patterned media. Candela CS20 and 6120 tools from KLA-Tencor map the optical properties of the disk surface, producing highresolution grayscale images of surface reflectivity and scattered light. Defects that have been identified in this manner are further characterized according to the morphology. The imprint process was tested after optimizing both the disk cleaning and adhesion layers processes that precede imprinting. An extended imprint run was performed and both the defect types and trends are reported.
Understanding and reduction of defects on finished EUV masks
NASA Astrophysics Data System (ADS)
Liang, Ted; Sanchez, Peter; Zhang, Guojing; Shu, Emily; Nagpal, Rajesh; Stivers, Alan
2005-05-01
To reduce the risk of EUV lithography adaptation for the 32nm technology node in 2009, Intel has operated a EUV mask Pilot Line since early 2004. The Pilot Line integrates all the necessary process modules including common tool sets shared with current photomask production as well as EUV specific tools. This integrated endeavor ensures a comprehensive understanding of any issues, and development of solutions for the eventual fabrication of defect-free EUV masks. Two enabling modules for "defect-free" masks are pattern inspection and repair, which have been integrated into the Pilot Line. This is the first time we are able to look at real defects originated from multilayer blanks and patterning process on finished masks over entire mask area. In this paper, we describe our efforts in the qualification of DUV pattern inspection and electron beam mask repair tools for Pilot Line operation, including inspection tool sensitivity, defect classification and characterization, and defect repair. We will discuss the origins of each of the five classes of defects as seen by DUV pattern inspection tool on finished masks, and present solutions of eliminating and mitigating them.
Dirt detection on brown eggs by means of color computer vision.
Mertens, K; De Ketelaere, B; Kamers, B; Bamelis, F R; Kemps, B J; Verhoelst, E M; De Baerdemaeker, J G; Decuypere, E M
2005-10-01
In the last 20 yr, different methods for detecting defects in eggs were developed. Until now, no satisfying technique existed to sort and quantify dirt on eggshells. The work presented here focuses on the design of an off-line computer vision system to differentiate and quantify the presence of different dirt stains on brown eggs: dark (feces), white (uric acid), blood, and yolk stains. A system that provides uniform light exposure around the egg was designed. In this uniform light, pictures of dirty and clean eggs were taken, stored, and analyzed. The classification was based on a few standard logical operators, allowing for a quick implementation in an online set-up. In an experiment, 100 clean and 100 dirty eggs were used to validate the classification algorithm. The designed vision system showed an accuracy of 99% for the detection of dirt stains. Two percent of the clean eggs had a light-colored eggshell and were subsequently mistaken for showing large white stains. The accuracy of differentiation of the different kinds of dirt stains was 91%. Of the eggs with dark stains, 10.81% were mistaken for having bloodstains, and 33.33% of eggs with bloodstains were mistaken for having dark stains. The developed system is possibly a first step toward an on line dirt evaluation technique for brown eggs.
In-TFT-array-process micro defect inspection using nonlinear principal component analysis.
Liu, Yi-Hung; Wang, Chi-Kai; Ting, Yung; Lin, Wei-Zhi; Kang, Zhi-Hao; Chen, Ching-Shun; Hwang, Jih-Shang
2009-11-20
Defect inspection plays a critical role in thin film transistor liquid crystal display (TFT-LCD) manufacture, and has received much attention in the field of automatic optical inspection (AOI). Previously, most focus was put on the problems of macro-scale Mura-defect detection in cell process, but it has recently been found that the defects which substantially influence the yield rate of LCD panels are actually those in the TFT array process, which is the first process in TFT-LCD manufacturing. Defect inspection in TFT array process is therefore considered a difficult task. This paper presents a novel inspection scheme based on kernel principal component analysis (KPCA) algorithm, which is a nonlinear version of the well-known PCA algorithm. The inspection scheme can not only detect the defects from the images captured from the surface of LCD panels, but also recognize the types of the detected defects automatically. Results, based on real images provided by a LCD manufacturer in Taiwan, indicate that the KPCA-based defect inspection scheme is able to achieve a defect detection rate of over 99% and a high defect classification rate of over 96% when the imbalanced support vector machine (ISVM) with 2-norm soft margin is employed as the classifier. More importantly, the inspection time is less than 1 s per input image.
Defect classification in sparsity-based structural health monitoring
NASA Astrophysics Data System (ADS)
Golato, Andrew; Ahmad, Fauzia; Santhanam, Sridhar; Amin, Moeness G.
2017-05-01
Guided waves have gained popularity in structural health monitoring (SHM) due to their ability to inspect large areas with little attenuation, while providing rich interactions with defects. For thin-walled structures, the propagating waves are Lamb waves, which are a complex but well understood type of guided waves. Recent works have cast the defect localization problem of Lamb wave based SHM within the sparse reconstruction framework. These methods make use of a linear model relating the measurements with the scene reflectivity under the assumption of point-like defects. However, most structural defects are not perfect points but tend to assume specific forms, such as surface cracks or internal cracks. Knowledge of the "type" of defects is useful in the assessment phase of SHM. In this paper, we present a dual purpose sparsity-based imaging scheme which, in addition to accurately localizing defects, properly classifies the defects present simultaneously. The proposed approach takes advantage of the bias exhibited by certain types of defects toward a specific Lamb wave mode. For example, some defects strongly interact with the anti-symmetric modes, while others strongly interact with the symmetric modes. We build model based dictionaries for the fundamental symmetric and anti-symmetric wave modes, which are then utilized in unison to properly localize and classify the defects present. Simulated data of surface and internal defects in a thin Aluminum plate are used to validate the proposed scheme.
Murad-Regadas, S M; Karbage, S A; Bezerra, L S; Regadas, F S P; da Silva Vilarinho, A; Borges, L B; Regadas Filho, F S P; Veras, L B
2017-07-01
The aim of this study was to evaluate the role of dynamic translabial ultrasound (TLUS) in the assessment of pelvic floor dysfunction and compare the results with echodefecography (EDF) combined with the endovaginal approach. Consecutive female patients with pelvic floor dysfunction were eligible. Each patient was assessed with EDF combined with the endovaginal approach and TLUS. The diagnostic accuracy of the TLUS was evaluated using the results of EDF as the standard for comparison. A total of 42 women were included. Four sphincter defects were identified with both techniques, and EDF clearly showed if the defect was partial or total and additionally identified the pubovisceral muscle defect. There was substantial concordance regarding normal relaxation and anismus. Perfect concordance was found with rectocele and cystocele. The rectocele depth was measured with TLUS and quantified according to the EDF classification. Fair concordance was found for intussusception. There was no correlation between the displacement of the puborectal muscle at maximum straining on EDF with the displacement of the anorectal junction (ARJ), compared at rest with maximal straining on TLUS to determine perineal descent (PD). The mean ARJ displacement was similar in patients with normal and those with excessive PD on TLUS. Both modalities can be used as a method to assess pelvic floor dysfunction. The EDF using 3D anorectal and endovaginal approaches showed advantages in identification of the anal sphincters and pubodefects (partial or total). There was good correlation between the two techniques, and a TLUS rectocele classification based on size that corresponds to the established classification using EDF was established.
NASA Astrophysics Data System (ADS)
Zhang, Zhifen; Chen, Huabin; Xu, Yanling; Zhong, Jiyong; Lv, Na; Chen, Shanben
2015-08-01
Multisensory data fusion-based online welding quality monitoring has gained increasing attention in intelligent welding process. This paper mainly focuses on the automatic detection of typical welding defect for Al alloy in gas tungsten arc welding (GTAW) by means of analzing arc spectrum, sound and voltage signal. Based on the developed algorithms in time and frequency domain, 41 feature parameters were successively extracted from these signals to characterize the welding process and seam quality. Then, the proposed feature selection approach, i.e., hybrid fisher-based filter and wrapper was successfully utilized to evaluate the sensitivity of each feature and reduce the feature dimensions. Finally, the optimal feature subset with 19 features was selected to obtain the highest accuracy, i.e., 94.72% using established classification model. This study provides a guideline for feature extraction, selection and dynamic modeling based on heterogeneous multisensory data to achieve a reliable online defect detection system in arc welding.
Cosgrove, Casey M; Cohn, David E; Hampel, Heather; Frankel, Wendy L; Jones, Dan; McElroy, Joseph P; Suarez, Adrian A; Zhao, Weiqiang; Chen, Wei; Salani, Ritu; Copeland, Larry J; O'Malley, David M; Fowler, Jeffrey M; Yilmaz, Ahmet; Chassen, Alexis S; Pearlman, Rachel; Goodfellow, Paul J; Backes, Floor J
2017-09-01
To determine the relationship between mismatch repair (MMR) classification and clinicopathologic features including tumor volume, and explore outcomes by MMR class in a contemporary cohort. Single institution cohort evaluating MMR classification for endometrial cancers (EC). MMR immunohistochemistry (IHC)±microsatellite instability (MSI) testing and reflex MLH1 methylation testing was performed. Tumors with MMR abnormalities by IHC or MSI and MLH1 methylation were classified as epigenetic MMR deficiency while those without MLH1 methylation were classified as probable MMR mutations. Clinicopathologic characteristics were analyzed. 466 endometrial cancers were classified; 75% as MMR proficient, 20% epigenetic MMR defects, and 5% as probable MMR mutations. Epigenetic MMR defects were associated with advanced stage, higher grade, presence of lymphovascular space invasion, and older age. MMR class was significantly associated with tumor volume, an association not previously reported. The epigenetic MMR defect tumors median volume was 10,220mm 3 compared to 3321mm 3 and 2,846mm 3 , for MMR proficient and probable MMR mutations respectively (P<0.0001). Higher tumor volume was associated with lymph node involvement. Endometrioid EC cases with epigenetic MMR defects had significantly reduced recurrence-free survival (RFS). Among advanced stage (III/IV) endometrioid EC the epigenetic MMR defect group was more likely to recur compared to the MMR proficient group (47.7% vs 3.4%) despite receiving similar adjuvant therapy. In contrast, there was no difference in the number of early stage recurrences for the different MMR classes. MMR testing that includes MLH1 methylation analysis defines a subset of tumors that have worse prognostic features and reduced RFS. Copyright © 2017 Elsevier Inc. All rights reserved.
Öcal, Gönül; Berberoğlu, Merih; Sıklar, Zeynep; Aycan, Zehra; Hacıhamdioglu, Bülent; Savas Erdeve, Şenay; Çamtosun, Emine; Kocaay, Pınar; Ruhi, Hatice I; Kılıç, Birim G; Tukun, Ajlan
2015-02-01
The aim of our study was to determine the etiologic distribution of 46,XX disorder of sexual development (DSD) according to the new DSD classification system and to evaluate the clinical features of this DSD subgroup in our patient cohort. The evaluation criteria and clinical findings of 95 46,XX patients were described by clinical presentation, gonadal morphology, genital anatomy, associated dysmorphic features, presence during prenatal period with/without postnatal virilization, hormonal characteristics, and presence or absence of steroidogenic defects among 319 patients with DSD. Types and ratios of each presentation of our 95 patients with 46,XX DSD were as follows: 82 had androgen excess (86.3%): (74 had classical congenital adrenal hyperplasia, 2 had CAH variant possibility of P450-oxidoreductase gene defect), 6 had disorders of ovarian development (6.3%): (1 patient had gonadal dysgenesis with virilization at birth with bilateral streak gonad, 4 patients had complete gonadal dysgenesis, and 1 patient had ovotesticular DSD) and 7 had other 46,XX DSD. Two sisters, who had 46,XX complete gonadal dysgenesis,were diagnosed with Perrault Syndrome with ovarian failure due to streak gonads and associated with sensorineural deafness. 46,XX DSD are usually derived from intrauterine virilization and CAH is the most common cause of 46,XX DSD due to fetal androgen exposure. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
A new computer-based Farnsworth Munsell 100-hue test for evaluation of color vision.
Ghose, Supriyo; Parmar, Twinkle; Dada, Tanuj; Vanathi, Murugesan; Sharma, Sourabh
2014-08-01
To evaluate a computer-based Farnsworth-Munsell (FM) 100-hue test and compare it with a manual FM 100-hue test in normal and congenital color-deficient individuals. Fifty color defective subjects and 200 normal subjects with a best-corrected visual acuity ≥ 6/12 were compared using a standard manual FM 100-hue test and a computer-based FM 100-hue test under standard operating conditions as recommended by the manufacturer after initial trial testing. Parameters evaluated were total error scores (TES), type of defect and testing time. Pearson's correlation coefficient was used to determine the relationship between the test scores. Cohen's kappa was used to assess agreement of color defect classification between the two tests. A receiver operating characteristic curve was used to determine the optimal cut-off score for the computer-based FM 100-hue test. The mean time was 16 ± 1.5 (range 6-20) min for the manual FM 100-hue test and 7.4 ± 1.4 (range 5-13) min for the computer-based FM 100-hue test, thus reducing testing time to <50 % (p < 0.05). For grading color discrimination, Pearson's correlation coefficient for TES between the two tests was 0.91 (p < 0.001). For color defect classification, Cohen's agreement coefficient was 0.98 (p < 0.01). The computer-based FM 100-hue is an effective and rapid method for detecting, classifying and grading color vision anomalies.
Neural-Fuzzy model Based Steel Pipeline Multiple Cracks Classification
NASA Astrophysics Data System (ADS)
Elwalwal, Hatem Mostafa; Mahzan, Shahruddin Bin Hj.; Abdalla, Ahmed N.
2017-10-01
While pipes are cheaper than other means of transportation, this cost saving comes with a major price: pipes are subject to cracks, corrosion etc., which in turn can cause leakage and environmental damage. In this paper, Neural-Fuzzy model for multiple cracks classification based on Lamb Guide Wave. Simulation results for 42 sample were collected using ANSYS software. The current research object to carry on the numerical simulation and experimental study, aiming at finding an effective way to detection and the localization of cracks and holes defects in the main body of pipeline. Considering the damage form of multiple cracks and holes which may exist in pipeline, to determine the respective position in the steel pipe. In addition, the technique used in this research a guided lamb wave based structural health monitoring method whereas piezoelectric transducers will use as exciting and receiving sensors by Pitch-Catch method. Implementation of simple learning mechanism has been developed specially for the ANN for fuzzy the system represented.
Nonlinear, non-stationary image processing technique for eddy current NDE
NASA Astrophysics Data System (ADS)
Yang, Guang; Dib, Gerges; Kim, Jaejoon; Zhang, Lu; Xin, Junjun; Udpa, Lalita
2012-05-01
Automatic analysis of eddy current (EC) data has facilitated the analysis of large volumes of data generated in the inspection of steam generator tubes in nuclear power plants. The traditional procedure for analysis of EC data includes data calibration, pre-processing, region of interest (ROI) detection, feature extraction and classification. Accurate ROI detection has been enhanced by pre-processing, which involves reducing noise and other undesirable components as well as enhancing defect indications in the raw measurement. This paper presents the Hilbert-Huang Transform (HHT) for feature extraction and support vector machine (SVM) for classification. The performance is shown to significantly better than the existing rule based classification approach used in industry.
Classification of defects in honeycomb composite structure of helicopter rotor blades
NASA Astrophysics Data System (ADS)
Balaskó, M.; Sváb, E.; Molnár, Gy.; Veres, I.
2005-04-01
The use of non-destructive testing methods to qualify the state of rotor blades with respect to their expected flight hours, with the aim to extend their lifetime without any risk of breakdown, is an important financial demand. In order to detect the possible defects in the composite structure of Mi-8 and Mi-24 type helicopter rotor blades used by the Hungarian Army, we have performed combined neutron- and X-ray radiography measurements at the Budapest Research Reactor. Several types of defects were detected, analysed and typified. Among the most frequent and important defects observed were cavities, holes and/or cracks in the sealing elements on the interface of the honeycomb structure and the section boarders. Inhomogeneities of the resin materials (resin-rich or starved areas) at the core-honeycomb surfaces proved to be an other important point. Defects were detected at the adhesive filling, and water percolation was visualized at the sealing interfaces of the honeycomb sections. Corrosion effects, and metal inclusions have also been detected.
In-TFT-Array-Process Micro Defect Inspection Using Nonlinear Principal Component Analysis
Liu, Yi-Hung; Wang, Chi-Kai; Ting, Yung; Lin, Wei-Zhi; Kang, Zhi-Hao; Chen, Ching-Shun; Hwang, Jih-Shang
2009-01-01
Defect inspection plays a critical role in thin film transistor liquid crystal display (TFT-LCD) manufacture, and has received much attention in the field of automatic optical inspection (AOI). Previously, most focus was put on the problems of macro-scale Mura-defect detection in cell process, but it has recently been found that the defects which substantially influence the yield rate of LCD panels are actually those in the TFT array process, which is the first process in TFT-LCD manufacturing. Defect inspection in TFT array process is therefore considered a difficult task. This paper presents a novel inspection scheme based on kernel principal component analysis (KPCA) algorithm, which is a nonlinear version of the well-known PCA algorithm. The inspection scheme can not only detect the defects from the images captured from the surface of LCD panels, but also recognize the types of the detected defects automatically. Results, based on real images provided by a LCD manufacturer in Taiwan, indicate that the KPCA-based defect inspection scheme is able to achieve a defect detection rate of over 99% and a high defect classification rate of over 96% when the imbalanced support vector machine (ISVM) with 2-norm soft margin is employed as the classifier. More importantly, the inspection time is less than 1 s per input image. PMID:20057957
Parnell, Aimee S; Shults, Justine; Gaynor, J William; Leonard, Mary B; Dai, Dingwei; Feudtner, Chris
2014-02-01
Administrative data are increasingly used to evaluate clinical outcomes and quality of care in pediatric congenital heart surgery (CHS) programs. Several published analyses of large pediatric administrative data sets have relied on the All Patient Refined Diagnosis Related Groups (APR-DRG, version 24) diagnostic classification system. The accuracy of this classification system for patients undergoing CHS is unclear. We performed a retrospective cohort study of all 14,098 patients 0 to 5 years of age undergoing any of six selected congenital heart operations, ranging in complexity from isolated closure of a ventricular septal defect to single-ventricle palliation, at 40 tertiary-care pediatric centers in the Pediatric Health Information Systems database between 2007 and 2010. Assigned APR-DRGs (cardiac versus noncardiac) were compared using χ2 or Fisher's exact tests between those patients admitted during the first day of life versus later and between those receiving extracorporeal membrane oxygenation support versus those not. Recursive partitioning was used to assess the greatest determinants of APR-DRG type in the model. Every patient admitted on day 1 of life was assigned to a noncardiac APR-DRG (p<0.001 for each procedure). Similarly, use of extracorporeal membrane oxygenation was highly associated with misclassification of CHS patients into a noncardiac APR-DRG (p<0.001 for each procedure). Cases misclassified into a noncardiac APR-DRG experienced a significantly increased mortality (p<0.001). In classifying patients undergoing CHS, APR-DRG coding has systematic misclassifications, which may result in inaccurate reporting of CHS case volumes and mortality. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Applications of color machine vision in the agricultural and food industries
NASA Astrophysics Data System (ADS)
Zhang, Min; Ludas, Laszlo I.; Morgan, Mark T.; Krutz, Gary W.; Precetti, Cyrille J.
1999-01-01
Color is an important factor in Agricultural and the Food Industry. Agricultural or prepared food products are often grade by producers and consumers using color parameters. Color is used to estimate maturity, sort produce for defects, but also perform genetic screenings or make an aesthetic judgement. The task of sorting produce following a color scale is very complex, requires special illumination and training. Also, this task cannot be performed for long durations without fatigue and loss of accuracy. This paper describes a machine vision system designed to perform color classification in real-time. Applications for sorting a variety of agricultural products are included: e.g. seeds, meat, baked goods, plant and wood.FIrst the theory of color classification of agricultural and biological materials is introduced. Then, some tools for classifier development are presented. Finally, the implementation of the algorithm on real-time image processing hardware and example applications for industry is described. This paper also presented an image analysis algorithm and a prototype machine vision system which was developed for industry. This system will automatically locate the surface of some plants using digital camera and predict information such as size, potential value and type of this plant. The algorithm developed will be feasible for real-time identification in an industrial environment.
Digitized Speech Characteristics in Patients with Maxillectomy Defects.
Elbashti, Mahmoud E; Sumita, Yuka I; Hattori, Mariko; Aswehlee, Amel M; Taniguchi, Hisashi
2017-12-06
Accurate evaluation of speech characteristics through formant frequency measurement is important for proper speech rehabilitation in patients after maxillectomy. This study aimed to evaluate the utility of digital acoustic analysis and vowel pentagon space for the prediction of speech ability after maxillectomy, by comparing the acoustic characteristics of vowel articulation in three classes of maxillectomy defects. Aramany's classifications I, II, and IV were used to group 27 male patients after maxillectomy. Digital acoustic analysis of five Japanese vowels-/a/, /e/, /i/, /o/, and /u/-was performed using a speech analysis system. First formant (F1) and second formant (F2) frequencies were calculated using an autocorrelation method. Data were plotted on an F1-F2 plane for each patient, and the F1 and F2 ranges were calculated. The vowel pentagon spaces were also determined. One-way ANOVA was applied to compare all results between the three groups. Class II maxillectomy patients had a significantly higher F2 range than did Class I and Class IV patients (p = 0.002). In contrast, there was no significant difference in the F1 range between the three classes. The vowel pentagon spaces were significantly larger in class II maxillectomy patients than in Class I and Class IV patients (p = 0.014). The results of this study indicate that the acoustic characteristics of maxillectomy patients are affected by the defect area. This finding may provide information for obturator design based on vowel articulation and defect class. © 2017 by the American College of Prosthodontists.
Supramolecular structure of polymer binders and composites: targeted control based on the hierarchy
NASA Astrophysics Data System (ADS)
Matveeva, Larisa; Belentsov, Yuri
2017-10-01
The article discusses the problem of targeted control over properties by modifying the supramolecular structure of polymer binders and composites based on their hierarchy. Control over the structure formation of polymers and introduction of modifying additives should be tailored to the specific hierarchical structural levels. Characteristics of polymer materials are associated with structural defects, which also display a hierarchical pattern. Classification of structural defects in polymers is presented. The primary structural level (nano level) of supramolecular formations is of great importance to the reinforcement and regulation of strength characteristics.
Empirical Mode Decomposition and Neural Networks on FPGA for Fault Diagnosis in Induction Motors
Garcia-Perez, Arturo; Osornio-Rios, Roque Alfredo; Romero-Troncoso, Rene de Jesus
2014-01-01
Nowadays, many industrial applications require online systems that combine several processing techniques in order to offer solutions to complex problems as the case of detection and classification of multiple faults in induction motors. In this work, a novel digital structure to implement the empirical mode decomposition (EMD) for processing nonstationary and nonlinear signals using the full spline-cubic function is presented; besides, it is combined with an adaptive linear network (ADALINE)-based frequency estimator and a feed forward neural network (FFNN)-based classifier to provide an intelligent methodology for the automatic diagnosis during the startup transient of motor faults such as: one and two broken rotor bars, bearing defects, and unbalance. Moreover, the overall methodology implementation into a field-programmable gate array (FPGA) allows an online and real-time operation, thanks to its parallelism and high-performance capabilities as a system-on-a-chip (SoC) solution. The detection and classification results show the effectiveness of the proposed fused techniques; besides, the high precision and minimum resource usage of the developed digital structures make them a suitable and low-cost solution for this and many other industrial applications. PMID:24678281
Empirical mode decomposition and neural networks on FPGA for fault diagnosis in induction motors.
Camarena-Martinez, David; Valtierra-Rodriguez, Martin; Garcia-Perez, Arturo; Osornio-Rios, Roque Alfredo; Romero-Troncoso, Rene de Jesus
2014-01-01
Nowadays, many industrial applications require online systems that combine several processing techniques in order to offer solutions to complex problems as the case of detection and classification of multiple faults in induction motors. In this work, a novel digital structure to implement the empirical mode decomposition (EMD) for processing nonstationary and nonlinear signals using the full spline-cubic function is presented; besides, it is combined with an adaptive linear network (ADALINE)-based frequency estimator and a feed forward neural network (FFNN)-based classifier to provide an intelligent methodology for the automatic diagnosis during the startup transient of motor faults such as: one and two broken rotor bars, bearing defects, and unbalance. Moreover, the overall methodology implementation into a field-programmable gate array (FPGA) allows an online and real-time operation, thanks to its parallelism and high-performance capabilities as a system-on-a-chip (SoC) solution. The detection and classification results show the effectiveness of the proposed fused techniques; besides, the high precision and minimum resource usage of the developed digital structures make them a suitable and low-cost solution for this and many other industrial applications.
NASA Astrophysics Data System (ADS)
Garcia-Allende, Pilar Beatriz; Conde, Olga M.; Madruga, Francisco J.; Cubillas, Ana M.; Lopez-Higuera, Jose M.
2008-03-01
A non-intrusive infrared sensor for the detection of spurious elements in an industrial raw material chain has been developed. The system is an extension to the whole near infrared range of the spectrum of a previously designed system based on the Vis-NIR range (400 - 1000 nm). It incorporates a hyperspectral imaging spectrograph able to register simultaneously the NIR reflected spectrum of the material under study along all the points of an image line. The working material has been different tobacco leaf blends mixed with typical spurious elements of this field such as plastics, cardboards, etc. Spurious elements are discriminated automatically by an artificial neural network able to perform the classification with a high degree of accuracy. Due to the high amount of information involved in the process, Principal Component Analysis is first applied to perform data redundancy removal. By means of the extension to the whole NIR range of the spectrum, from 1000 to 2400 nm, the characterization of the material under test is highly improved. The developed technique could be applied to the classification and discrimination of other materials, and, as a consequence of its non-contact operation it is particularly suitable for food quality control.
Purcaro, Giorgia; Cordero, Chiara; Liberto, Erica; Bicchi, Carlo; Conte, Lanfranco S
2014-03-21
This study investigates the applicability of an iterative approach aimed at defining a chemical blueprint of virgin olive oil volatiles to be correlated to the product sensory quality. The investigation strategy proposed allows to fully exploit the informative content of a comprehensive multidimensional gas chromatography (GC×GC) coupled to a mass spectrometry (MS) data set. Olive oil samples (19), including 5 reference standards, obtained from the International Olive Oil Council, and commercial samples, were submitted to a sensory evaluation by a Panel test, before being analyzed in two laboratories using different instrumentation, column set, and software elaboration packages in view of a cross-validation of the entire methodology. A first classification of samples based on untargeted peak features information, was obtained on raw data from two different column combinations (apolar×polar and polar×apolar) by applying unsupervised multivariate analysis (i.e., principal component analysis-PCA). However, to improve effectiveness and specificity of this classification, peak features were reliably identified (261 compounds), on the basis of the MS spectrum and linear retention index matching, and subjected to successive pair-wise comparisons based on 2D patterns, which revealed peculiar distribution of chemicals correlated with samples sensory classification. The most informative compounds were thus identified and collected in a "blueprint" of specific defects (or combination of defects) successively adopted to discriminate Extra Virgin from defected oils (i.e., lampante oil) with the aid of a supervised approach, i.e., partial least squares-discriminant analysis (PLS-DA). In this last step, the principles of sensomics, which assigns higher information potential to analytes with lower odor threshold proved to be successful, and a much more powerful discrimination of samples was obtained in view of a sensory quality assessment. Copyright © 2014 Elsevier B.V. All rights reserved.
Sensory properties of Californian and imported extra virgin olive oils.
Delgado, Claudia; Guinard, Jean-Xavier
2011-04-01
Production and consumption of extra-virgin olive has been increasing in the United States, particularly in California. The objective of this study was to compare the sensory characteristics of 22 extra virgin olive oils (EVOO) from California, Italy, Spain, Chile, and Australia using a generic descriptive analysis. A total of 22 sensory attributes were identified and defined by the descriptive panel. With the exception of thick and citrus, all sensory attributes were significantly different among the oils. Canonical Variate Analysis (CVA) showed that California oils differed from some imported EVOOs, mainly by their absence of defects. A second analysis, of only those attributes included in the International Olive Council (IOC) official scorecard, provided a less detailed description of the samples and did not allow for a full characterization of the oils. While the IOC attributes allowed for faster classification in terms of clean versus defective EVOOs, the more comprehensive descriptive analysis provided both more information and a more refined classification of the samples. Variety and region of origin were important factors in the classification of both Californian and imported EVOOs. Measuring olive oil sensory quality using the IOC method-positive attributes of fruitiness, bitterness, and pungency, and defects including fusty, musty, winey, and rancid-allows for the certification of oils as extra virgin but it provides limited information on the sensory characteristics of the oils. A full descriptive profile, on the other hand, provides information that can be used by producers in the processing and marketing of their oils, and is a useful tool in the education of consumers about the wide range of (positive) sensory attributes in EVOO and the various sensory styles of EVOO.
Sphincter lesions observed on ultrasound after transanal endoscopic surgery.
Mora López, Laura; Serra-Aracil, Xavier; Navarro Soto, Salvador
2015-12-14
To assess the morphological impact of transanal endoscopic surgery on the sphincter apparatus using the modified Starck classification. A prospective, observational study of 118 consecutive patients undergoing Transanal Endoscopic Operation/Transanal Endoscopic Microsurgery (TEO/TEM) from March 2013 to May 2014 was performed. All the patients underwent an endoanal ultrasound prior to surgery and one and four months postoperatively in order to measure sphincter width, identify sphincter defects and to quantify them in terms of the level, depth and size of the affected anal canal. To assess the lesions, we used the "modified" Starck classification, which incorporates the variable "sphincter fragmentation". The results were correlated with the Wexner incontinence questionnaire. Of the 118 patients, twelve (sphincter lesions) were excluded. The results of the 106 patients were as follows after one month: 31 (29.2%) lesions found on ultrasound after one month, median overall Starck score of 4 (range 3-6); 10 (9.4%) defects in the internal anal sphincter (IAS) and 3 (2.8%) in the external anal sphincter (EAS); 17 patients (16%) had fragmentation of the sphincter apparatus with both sphincters affected in one case. At four months: 7 (6.6%) defects, all in the IAS, overall median Starck score of 4 (range 3-6). Mean IAS widths were 3.5 mm (SD 1.14) preoperatively, 4.38 mm (SD 2.1) one month postoperatively and 4.03 mm (SD 1.46) four months postoperatively. The only statistically significant difference in sphincter width in the IAS measurements was between preoperatively and one month postoperatively. No incontinence was reported, even in cases of ultrasound abnormalities. TEO/TEM may produce ultrasound abnormalities but this is not accompanied by clinical changes in continence. The modified Starck classification is useful for describing and managing these disorders.
Optical method and apparatus for detection of surface and near-subsurface defects in dense ceramics
Ellingson, William A.; Brada, Mark P.
1995-01-01
A laser is used in a non-destructive manner to detect surface and near-subsurface defects in dense ceramics and particularly in ceramic bodies with complex shapes such as ceramic bearings, turbine blades, races, and the like. The laser's wavelength is selected based upon the composition of the ceramic sample and the laser can be directed on the sample while the sample is static or in dynamic rotate or translate motion. Light is scattered off surface and subsurface defects using a preselected polarization. The change in polarization angle is used to select the depth and characteristics of surface/subsurface defects. The scattered light is detected by an optical train consisting of a charge coupled device (CCD), or vidicon, television camera which, in turn, is coupled to a video monitor and a computer for digitizing the image. An analyzing polarizer in the optical train allows scattered light at a given polarization angle to be observed for enhancing sensitivity to either surface or near-subsurface defects. Application of digital image processing allows subtraction of digitized images in near real-time providing enhanced sensitivity to subsurface defects. Storing known "feature masks" of identified defects in the computer and comparing the detected scatter pattern (Fourier images) with the stored feature masks allows for automatic classification of detected defects.
Inspection of imprint lithography patterns for semiconductor and patterned media
NASA Astrophysics Data System (ADS)
Resnick, Douglas J.; Haase, Gaddi; Singh, Lovejeet; Curran, David; Schmid, Gerard M.; Luo, Kang; Brooks, Cindy; Selinidis, Kosta; Fretwell, John; Sreenivasan, S. V.
2010-03-01
Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Acceptance of imprint lithography for manufacturing will require demonstration that it can attain defect levels commensurate with the requirements of cost-effective device production. This work summarizes the results of defect inspections of semiconductor masks, wafers and hard disks patterned using Jet and Flash Imprint Lithography (J-FILTM). Inspections were performed with optical and e-beam based automated inspection tools. For the semiconductor market, a test mask was designed which included dense features (with half pitches ranging between 32 nm and 48 nm) containing an extensive array of programmed defects. For this work, both e-beam inspection and optical inspection were used to detect both random defects and the programmed defects. Analytical SEMs were then used to review the defects detected by the inspection. Defect trends over the course of many wafers were observed with another test mask using a KLA-T 2132 optical inspection tool. The primary source of defects over 2000 imprints were particle related. For the hard drive market, it is important to understand the defectivity of both the template and the imprinted disk. This work presents a methodology for automated pattern inspection and defect classification for imprint-patterned media. Candela CS20 and 6120 tools from KLA-Tencor map the optical properties of the disk surface, producing highresolution grayscale images of surface reflectivity, scattered light, phase shift, etc. Defects that have been identified in this manner are further characterized according to the morphology
Turan, Serap
2017-01-01
Disorders related to parathyroid hormone (PTH) resistance and PTH signaling pathway impairment are historically classified under the term of pseudohypoparathyroidism (PHP). The disease was first described and named by Fuller Albright and colleagues in 1942. Albright hereditary osteodystrophy (AHO) is described as an associated clinical entity with PHP, characterized by brachydactyly, subcutaneous ossifications, round face, short stature and a stocky build. The classification of PHP is further divided into PHP-Ia, pseudo-PHP (pPHP), PHP-Ib, PHP-Ic and PHP-II according to the presence or absence of AHO, together with an in vivo response to exogenous PTH and the measurement of Gsα protein activity in peripheral erythrocyte membranes in vitro. However, PHP classification fails to differentiate all patients with different clinical and molecular findings for PHP subtypes and classification become more complicated with more recent molecular characterization and new forms having been identified. So far, new classifications have been established by the EuroPHP network to cover all disorders of the PTH receptor and its signaling pathway. Inactivating PTH/PTH-related protein signaling disorder (iPPSD) is the new name proposed for a group of these disorders and which can be further divided into subtypes - iPPSD1 to iPPSD6. These are termed, starting from PTH receptor inactivation mutation (Eiken and Blomstrand dysplasia) as iPPSD1, inactivating Gsα mutations (PHP-Ia, PHP-Ic and pPHP) as iPPSD2, loss of methylation of GNAS DMRs (PHP-Ib) as iPPSD3, PRKAR1A mutations (acrodysostosis type 1) as iPPSD4, PDE4D mutations (acrodysostosis type 2) as iPPSD5 and PDE3A mutations (autosomal dominant hypertension with brachydactyly) as iPPSD6. iPPSDx is reserved for unknown molecular defects and iPPSDn+1 for new molecular defects which are yet to be described. With these new classifications, the aim is to clarify the borders of each different subtype of disease and make the classification according to molecular pathology. The iPPSD group is designed to be expandable and new classifications will readily fit into it as necessary. PMID:29280743
Turan, Serap
2017-12-30
Disorders related to parathyroid hormone (PTH) resistance and PTH signaling pathway impairment are historically classified under the term of pseudohypoparathyroidism (PHP). The disease was first described and named by Fuller Albright and colleagues in 1942. Albright hereditary osteodystrophy (AHO) is described as an associated clinical entity with PHP, characterized by brachydactyly, subcutaneous ossifications, round face, short stature and a stocky build. The classification of PHP is further divided into PHP-Ia, pseudo-PHP (pPHP), PHP-Ib, PHP-Ic and PHP-II according to the presence or absence of AHO, together with an in vivo response to exogenous PTH and the measurement of Gsα protein activity in peripheral erythrocyte membranes in vitro. However, PHP classification fails to differentiate all patients with different clinical and molecular findings for PHP subtypes and classification become more complicated with more recent molecular characterization and new forms having been identified. So far, new classifications have been established by the EuroPHP network to cover all disorders of the PTH receptor and its signaling pathway. Inactivating PTH/PTH-related protein signaling disorder (iPPSD) is the new name proposed for a group of these disorders and which can be further divided into subtypes - iPPSD1 to iPPSD6. These are termed, starting from PTH receptor inactivation mutation (Eiken and Blomstrand dysplasia) as iPPSD1, inactivating Gsα mutations (PHP-Ia, PHP-Ic and pPHP) as iPPSD2, loss of methylation of GNAS DMRs (PHP-Ib) as iPPSD3, PRKAR1A mutations (acrodysostosis type 1) as iPPSD4, PDE4D mutations (acrodysostosis type 2) as iPPSD5 and PDE3A mutations (autosomal dominant hypertension with brachydactyly) as iPPSD6. iPPSDx is reserved for unknown molecular defects and iPPSDn+1 for new molecular defects which are yet to be described. With these new classifications, the aim is to clarify the borders of each different subtype of disease and make the classification according to molecular pathology. The iPPSD group is designed to be expandable and new classifications will readily fit into it as necessary.
Vasculitic wheel - an algorithmic approach to cutaneous vasculitides.
Ratzinger, Gudrun; Zelger, Bettina Gudrun; Carlson, J Andrew; Burgdorf, Walter; Zelger, Bernhard
2015-11-01
Previous classifications of vasculitides suffer from several defects. First, classifications may follow different principles including clinicopathologic findings, etiology, pathogenesis, prognosis, or therapeutic options. Second, authors fail to distinguish between vasculitis and coagulopathy. Third, vasculitides are systemic diseases. Organ-specific variations make morphologic findings difficult to compare. Fourth, subtle changes are recognized in the skin, but may be asymptomatic in other organs. Our aim was to use the skin and subcutis as a model and the clinicopathologic correlation as the basic process for classification. We use an algorithmic approach with pattern analysis, which allows for consistent reporting of microscopic findings. We first differentiate between small and medium vessel vasculitis. In the second step, we differentiate the subtypes of small (capillaries versus postcapillary venules) and medium-sized (arterioles/arteries versus veins) vessels. In the final step, we differentiate, according to the predominant cell type, into leukocytoclastic and/or granulomatous vasculitis. Starting from leukocytoclastic vasculitis as a central reaction pattern of cutaneous small/medium vessel vasculitides, its relations or variations may be arranged around it like spokes of a wheel around the hub. This may help establish some basic order in this rather complex realm of cutaneous vasculitides, leading to a better understanding in a complicated field. © 2015 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.
7 CFR 51.3416 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... ring Internal Black Spot, Internal Discoloration, Vascular Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely within the vascular ring Hollow Heart or... diameter in a 10 ounce potato. 1 Internal Brown Spot and similar discoloration (Heat Necrosis) Not more...
7 CFR 51.3416 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... ring Internal Black Spot, Internal Discoloration, Vascular Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely within the vascular ring Hollow Heart or... diameter in a 10 ounce potato. 1 Internal Brown Spot and similar discoloration (Heat Necrosis) Not more...
7 CFR 51.3416 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Maximum allowed for U.S. No. 2 processing Occurring outside of or not entirely confined to the vascular ring Internal Black Spot, Internal Discoloration, Vascular Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely within the vascular ring Hollow Heart or...
Cleft Palate; A Multidiscipline Approach.
ERIC Educational Resources Information Center
Stark, Richard B., Ed.
Nineteen articles present a multidisciplinary approach to the management of facial clefts. The following subjects are discussed: the history of cleft lip and cleft palate surgery; cogenital defects; classification; the operation of a cleft palate clinic; physical examination of newborns with cleft lip and/or palate; nursing care; anesthesia;…
Disorders of Articulation. Prentice-Hall Foundations of Speech Pathology Series.
ERIC Educational Resources Information Center
Carrell, James A.
Designed for students of speech pathology and audiology and for practicing clinicians, the text considers the nature of the articulation process, criteria for diagnosis, and classification and etiology of disorders. Also discussed are phonetic characteristics, including phonemic errors and configurational and contextual defects; and functional…
A new classification scheme for treating blunt aortic injury.
Starnes, Benjamin W; Lundgren, Rachel S; Gunn, Martin; Quade, Samantha; Hatsukami, Thomas S; Tran, Nam T; Mokadam, Nahush; Aldea, Gabriel
2012-01-01
There are numerous questions about the treatment of blunt aortic injury (BAI), including the management of small intimal tears, what injury characteristics are predictive of death from rupture, and which patients actually need intervention. We used our experience in treating BAI during the past decade to create a classification scheme based on radiographic and clinical data and to provide clear treatment guidelines. The records of patients admitted with BAI from 1999 to 2008 were retrospectively reviewed. Patients with a radiographically or operatively confirmed diagnosis (echocardiogram, computed tomography, or angiography) of BAI were included. We created a classification system based on the presence or absence of an aortic external contour abnormality, defined as an alteration in the symmetric, round shape of the aorta: (1) intimal tear (IT)-absence of aortic external contour abnormality and intimal defect and/or thrombus of <10 mm in length or width; (2) large intimal flap (LIF)-absence of aortic external contour abnormality and intimal defect and/or thrombus of ≥10 mm in length or width; (3) pseudoaneurysm-presence of aortic external contour abnormality and contained rupture; (4) rupture-presence of aortic external contour abnormality and free contrast extravasation or hemothorax at thoracotomy. We identified 140 patients with BAI. Most injuries were pseudoaneurysm (71%) at the isthmus (70%), 16.4% had an IT, 5.7% had a LIF, and 6.4% had a rupture. Survival rates by classification were IT, 87%; LIF, 100%; pseudoaneurysm, 76%; and rupture, 11% (one patient). Of the ITs, LIFs, and pseudoaneurysms treated nonoperatively, none worsened, and 65% completely healed. No patient with an IT or LIF died. Most patients with ruptures lost vital signs before presentation or in the emergency department and did not survive. Hypotension before or at hospital presentation and size of the periaortic hematoma at the level of the aortic arch predicted likelihood of death from BAI. As a result of this new classification scheme, no patient without an external aortic contour abnormality died of their BAI. ITs can be managed nonoperatively. BAI patients with rupture will die, and resources could be prioritized elsewhere. Those with LIFs do well, and currently, most at our institution are treated with a stent graft. If a pseudoaneurysm is going to rupture, it does so early. Hematoma at the arch on computed tomography scan and hypotension before or at arrival help to predict which pseudoaneurysms need urgent repair. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Nie, Baisheng; Huang, Xin; Xue, Fei; Chen, Jiang; Liu, Xiaobing; Meng, Yangyang; Huang, Jinxin
2018-06-01
In order to enhance Chinese workers' occupational safety awareness, it is essential to learn from developed countries' experiences. This article investigates thoroughly occupational safety and health (OSH) in China and the UK; moreover, the article performs a comparison of Chinese and British OSH training-related laws, regulations and education system. The following conclusions are drawn: China's work safety continues to improve, but there is still a large gap compared with the UK. In China a relatively complete vocational education and training (VET) system has been established. However, there exist some defects in OSH. In the UK, the employer will not only pay attention to employees' physiological health, but also to their mental health. The UK's VET is characterized by classification and grading management, which helps integrate OSH into the whole education system. China can learn from the UK in the development of policies, VET and OSH training.
Characteristics of FDA drug recalls: A 30-month analysis.
Hall, Kelsey; Stewart, Tyler; Chang, Jongwha; Freeman, Maisha Kelly
2016-02-15
The characteristics of drug recalls issued over 30 months by the Food and Drug Administration (FDA) were analyzed. All FDA-issued recalls for drugs (prescription and nonprescription, including dietary supplements) and biological products issued from June 20, 2012, to December 31, 2014, were included in this retrospective analysis. Data for all drug recalls were downloaded and sorted by the inclusion criteria from weekly FDA enforcement reports. The following data were analyzed: product type, recall firm, type of recall firm (compounding or noncompounding), country, voluntary or involuntary recall, method of communication of recall, recall number, FDA recall classification (class I, II, or III), product availability (prescription or nonprescription), reason for recall, recall initiation date, and recall report date. A total of 21,120 products were recalled during the 30-month study period. Of these, 3,045 drug products (14.4%) met the inclusion criteria and were analyzed. A total of 348 total manufacturers were associated with recalled drug products. The 5 firms most frequently involved in recalls accounted for 299, 273, 212, 118, and 112 recalls. The most common reasons for recalls were contamination, mislabeling, adverse reaction, defective product, and incorrect potency. There was a significant association between FDA recall classification and the following outcomes: reasons for recall, product availability, type of recall firm, and form of communication. An investigation of FDA drug recalls revealed that the five most common recall reasons were contamination, mislabeling, adverse reaction, defective product, and incorrect potency. Compounding firms were associated more frequently with contamination than were noncompounding firms. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Congenital cardiac disease in the newborn infant: past, present, and future.
Sadowski, Sharyl L
2009-03-01
Congenital heart defects are the most common of all congenital malformations, with a review of the literature reporting the incidence at 6 to 8 per 1000 live births. The Centers for Disease Control reports cyanotic heart defects occurred in 56.9 per 100,000 live births in the United States in 2005, with higher rates noted when maternal age exceeded 40 years. The incidence of congenital heart disease in premature infants is 12.5 per 1000 live births, excluding isolated patent ductus arteriosus and atrial septal defect. Despite advances in detection and treatment, congenital heart disease accounts for 3% of all infant deaths and 46% of death from congenital malformations. This article discusses the embryology, pathogenesis, clinical presentation, incidence, classifications, and management of congenital heart diseases.
Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya
2012-11-01
Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.
Photomask quality evaluation using lithography simulation and multi-detector MVM-SEM
NASA Astrophysics Data System (ADS)
Ito, Keisuke; Murakawa, Tsutomu; Fukuda, Naoki; Shida, Soichi; Iwai, Toshimichi; Matsumoto, Jun; Nakamura, Takayuki; Matsushita, Shohei; Hagiwara, Kazuyuki; Hara, Daisuke
2013-06-01
The detection and management of mask defects which are transferred onto wafer becomes more important day by day. As the photomask patterns becomes smaller and more complicated, using Inverse Lithography Technology (ILT) and Source Mask Optimization (SMO) with Optical Proximity Correction (OPC). To evaluate photomask quality, the current method uses aerial imaging by optical inspection tools. This technique at 1Xnm node has a resolution limit because small defects will be difficult to detect. We already reported the MEEF influence of high-end photomask using wide FOV SEM contour data of "E3630 MVM-SEM®" and lithography simulator "TrueMask® DS" of D2S Inc. in the prior paper [1]. In this paper we evaluate the correlation between our evaluation method and optical inspection tools as ongoing assessment. Also in order to reduce the defect classification work, we can compose the 3 Dimensional (3D) information of defects and can judge whether repairs of defects would be required. Moreover, we confirm the possibility of wafer plane CD measurement based on the combination between E3630 MVM-SEM® and 3D lithography simulation.
Branching points in the low-temperature dipolar hard sphere fluid
NASA Astrophysics Data System (ADS)
Rovigatti, Lorenzo; Kantorovich, Sofia; Ivanov, Alexey O.; Tavares, José Maria; Sciortino, Francesco
2013-10-01
In this contribution, we investigate the low-temperature, low-density behaviour of dipolar hard-sphere (DHS) particles, i.e., hard spheres with dipoles embedded in their centre. We aim at describing the DHS fluid in terms of a network of chains and rings (the fundamental clusters) held together by branching points (defects) of different nature. We first introduce a systematic way of classifying inter-cluster connections according to their topology, and then employ this classification to analyse the geometric and thermodynamic properties of each class of defects, as extracted from state-of-the-art equilibrium Monte Carlo simulations. By computing the average density and energetic cost of each defect class, we find that the relevant contribution to inter-cluster interactions is indeed provided by (rare) three-way junctions and by four-way junctions arising from parallel or anti-parallel locally linear aggregates. All other (numerous) defects are either intra-cluster or associated to low cluster-cluster interaction energies, suggesting that these defects do not play a significant part in the thermodynamic description of the self-assembly processes of dipolar hard spheres.
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the surface. Creasing Materially weakens the skin, or extends over more than one-third of the surface Seriously weakens the skin, or extends over more than one-half of the surface Very seriously weakens the skin, or is distributed over practically the entire surface. Dryness or mushy condition Affecting all...
Optical method and apparatus for detection of surface and near-subsurface defects in dense ceramics
Ellingson, W.A.; Brada, M.P.
1995-06-20
A laser is used in a non-destructive manner to detect surface and near-subsurface defects in dense ceramics and particularly in ceramic bodies with complex shapes such as ceramic bearings, turbine blades, races, and the like. The laser`s wavelength is selected based upon the composition of the ceramic sample and the laser can be directed on the sample while the sample is static or in dynamic rotate or translate motion. Light is scattered off surface and subsurface defects using a preselected polarization. The change in polarization angle is used to select the depth and characteristics of surface/subsurface defects. The scattered light is detected by an optical train consisting of a charge coupled device (CCD), or vidicon, television camera which, in turn, is coupled to a video monitor and a computer for digitizing the image. An analyzing polarizer in the optical train allows scattered light at a given polarization angle to be observed for enhancing sensitivity to either surface or near-subsurface defects. Application of digital image processing allows subtraction of digitized images in near real-time providing enhanced sensitivity to subsurface defects. Storing known ``feature masks`` of identified defects in the computer and comparing the detected scatter pattern (Fourier images) with the stored feature masks allows for automatic classification of detected defects. 29 figs.
Locating and classifying defects using an hybrid data base
NASA Astrophysics Data System (ADS)
Luna-Avilés, A.; Hernández-Gómez, L. H.; Durodola, J. F.; Urriolagoitia-Calderón, G.; Urriolagoitia-Sosa, G.; Beltrán Fernández, J. A.; Díaz Pineda, A.
2011-07-01
A computational inverse technique was used in the localization and classification of defects. Postulated voids of two different sizes (2 mm and 4 mm diameter) were introduced in PMMA bars with and without a notch. The bar dimensions are 200×20×5 mm. One half of them were plain and the other half has a notch (3 mm × 4 mm) which is close to the defect area (19 mm × 16 mm).This analysis was done with an Artificial Neural Network (ANN) and its optimization was done with an Adaptive Neuro Fuzzy Procedure (ANFIS). A hybrid data base was developed with numerical and experimental results. Synthetic data was generated with the finite element method using SOLID95 element of ANSYS code. A parametric analysis was carried out. Only one defect in such bars was taken into account and the first five natural frequencies were calculated. 460 cases were evaluated. Half of them were plain and the other half has a notch. All the input data was classified in two groups. Each one has 230 cases and corresponds to one of the two sort of voids mentioned above. On the other hand, experimental analysis was carried on with PMMA specimens of the same size. The first two natural frequencies of 40 cases were obtained with one void. The other three frequencies were obtained numerically. 20 of these bars were plain and the others have a notch. These experimental results were introduced in the synthetic data base. 400 cases were taken randomly and, with this information, the ANN was trained with the backpropagation algorithm. The accuracy of the results was tested with the 100 cases that were left. In the next stage of this work, the ANN output was optimized with ANFIS. Previous papers showed that localization and classification of defects was reduced as notches were introduced in such bars. In the case of this paper, improved results were obtained when a hybrid data base was used.
Hardware Neural Network for a Visual Inspection System
NASA Astrophysics Data System (ADS)
Chun, Seungwoo; Hayakawa, Yoshihiro; Nakajima, Koji
The visual inspection of defects in products is heavily dependent on human experience and instinct. In this situation, it is difficult to reduce the production costs and to shorten the inspection time and hence the total process time. Consequently people involved in this area desire an automatic inspection system. In this paper, we propose a hardware neural network, which is expected to provide high-speed operation for automatic inspection of products. Since neural networks can learn, this is a suitable method for self-adjustment of criteria for classification. To achieve high-speed operation, we use parallel and pipelining techniques. Furthermore, we use a piecewise linear function instead of a conventional activation function in order to save hardware resources. Consequently, our proposed hardware neural network achieved 6GCPS and 2GCUPS, which in our test sample proved to be sufficiently fast.
New data clustering for RBF classifier of agriculture products from x-ray images
NASA Astrophysics Data System (ADS)
Casasent, David P.; Chen, Xuewen
1999-08-01
Classification of real-time x-ray images of randomly oriented touching pistachio nuts is discussed. The ultimate objective is the development of a subsystem for automated non-invasive detection of defective product items on a conveyor belt. We discuss the use of clustering and how it is vital to achieve useful classification. New clustering methods using class identify and new cluster classes are advanced and shown to be of use for this application. Radial basis function neural net classifiers are emphasized. We expect our results to be of use for other classifiers and applications.
Current Strategies in Reconstruction of Maxillectomy Defects
Andrades, Patricio; Militsakh, Oleg; Hanasono, Matthew M.; Rieger, Jana; Rosenthal, Eben L.
2014-01-01
Objective To outline a contemporary review of defect classification and reconstructive options. Design Review article. Setting Tertiary care referral centers. Results Although prosthetic rehabilitation remains the standard of care in many institutions, the discomfort of wearing, removing, and cleaning a prosthesis; the inability to retain a prosthesis in large defects; and the frequent need for readjustments often limit the value of this cost-effective and successful method of restoring speech and mastication. However, flap reconstruction offers an option for many, although there is no agreement as to which techniques should be used for optimal reconstruction. Flap reconstruction also involves a longer recovery time with increased risk of surgical complications, has higher costs associated with the procedure, and requires access to a highly experienced surgeon. Conclusion The surgeon and reconstructive team must make individualized decisions based on the extent of the maxillectomy defect (eg, the resection of the infraorbital rim, the extent of palate excision, skin compromise) and the need for radiation therapy. PMID:21844415
Applied algorithm in the liner inspection of solid rocket motors
NASA Astrophysics Data System (ADS)
Hoffmann, Luiz Felipe Simões; Bizarria, Francisco Carlos Parquet; Bizarria, José Walter Parquet
2018-03-01
In rocket motors, the bonding between the solid propellant and thermal insulation is accomplished by a thin adhesive layer, known as liner. The liner application method involves a complex sequence of tasks, which includes in its final stage, the surface integrity inspection. Nowadays in Brazil, an expert carries out a thorough visual inspection to detect defects on the liner surface that may compromise the propellant interface bonding. Therefore, this paper proposes an algorithm that uses the photometric stereo technique and the K-nearest neighbor (KNN) classifier to assist the expert in the surface inspection. Photometric stereo allows the surface information recovery of the test images, while the KNN method enables image pixels classification into two classes: non-defect and defect. Tests performed on a computer vision based prototype validate the algorithm. The positive results suggest that the algorithm is feasible and when implemented in a real scenario, will be able to help the expert in detecting defective areas on the liner surface.
Lionel Penrose and the concept of normal variation in human intelligence.
Valles, Sean A
2012-03-01
Lionel Penrose (1898-1972) was an important leader during the mid-20th century decline of eugenics and the development of modern medical genetics. However, historians have paid little attention to his radical theoretical challenges to mainline eugenic concepts of mental disease. Working from a classification system developed with his colleague, E. O. Lewis, Penrose developed a statistically sophisticated and clinically grounded refutation of the popular position that low intelligence is inherently a disease state. In the early 1930s, Penrose advocated dividing "mental defect" (low intelligence) into two categories: "pathological mental defect," which is a disease state that can be traced to a distinct genetic or environmental cause, and "subcultural mental defect," which is not an inherent disease state, but rather a statistically necessary manifestation of human variation in intelligence. I explore the historical context and theoretical import of this contribution, discussing its rejection of typological thinking and noting that it preceded Theodosius Dobzhansky's better-known defense of human diversity. I illustrate the importance of Penrose's contribution with a discussion of an analogous situation in contemporary medicine, the controversial practice of using human growth hormone injections to treat "idiopathic short stature" (mere diminutive height, with no distinct cause). I show how Penrose's contributions to understanding human variation make such treatments appear quite misguided. Copyright © 2011 Elsevier Ltd. All rights reserved.
Optical classification for quality and defect analysis of train brakes
NASA Astrophysics Data System (ADS)
Glock, Stefan; Hausmann, Stefan; Gerke, Sebastian; Warok, Alexander; Spiess, Peter; Witte, Stefan; Lohweg, Volker
2009-06-01
In this paper we present an optical measurement system approach for quality analysis of brakes which are used in high-speed trains. The brakes consist of the so called brake discs and pads. In a deceleration process the discs will be heated up to 500°C. The quality measure is based on the fact that the heated brake discs should not generate hot spots inside the brake material. Instead, the brake disc should be heated homogeneously by the deceleration. Therefore, it makes sense to analyze the number of hot spots and their relative gradients to create a quality measure for train brakes. In this contribution we present a new approach for a quality measurement system which is based on an image analysis and classification of infra-red based heat images. Brake images which are represented in pseudo-color are first transformed in a linear grayscale space by a hue-saturation-intensity (HSI) space. This transform is necessary for the following gradient analysis which is based on gray scale gradient filters. Furthermore, different features based on Haralick's measures are generated from the gray scale and gradient images. A following Fuzzy-Pattern-Classifier is used for the classification of good and bad brakes. It has to be pointed out that the classifier returns a score value for each brake which is between 0 and 100% good quality. This fact guarantees that not only good and bad bakes can be distinguished, but also their quality can be labeled. The results show that all critical thermal patterns of train brakes can be sensed and verified.
Halliday, Jane; Collins, Veronica; Riley, Merilyn; Youssef, Danielle; Muggli, Evelyne
2009-01-01
With this study we aimed to compare survival rates for children with Down syndrome in 2 time periods, 1 before prenatal screening (1988-1990) and 1 contemporaneous with screening (1998-2000), and to examine the frequency of comorbidities and their influence on survival rates. Record-linkage was performed between the population-based Victorian Birth Defects Register and records of deaths in children up to 15 years of age collected under the auspice of the Consultative Council on Obstetric and Pediatric Mortality and Morbidity. Cases of Down syndrome were coded according to the presence or absence of comorbidities by using the International Classification of Diseases, Ninth Revision classification of birth defects. Kaplan-Meier survival functions and log rank tests for equality of survival distributions were performed. Of infants liveborn with Down syndrome in 1998-2000, 90% survived to 5 years of age, compared with 86% in the earlier cohort. With fetal deaths excluded, the proportion of isolated Down syndrome cases in the earlier cohort was 48.7% compared with 46.1% in the most recent cohort. In 1988-1990 there was at least 1 cardiac defect in 41.1% of cases and in 45.4% in 1998-2000. There was significant variation in survival rates for the different comorbidity groupings in the 1988-1990 cohort, but this was not so evident in the 1998-2000 cohort. Survival of children with Down syndrome continues to improve, and there is an overall survival figure of 90% to at least 5 years of age. It is clear from this study that prenatal screening technologies are not differentially ascertaining fetuses with Down syndrome and additional defects, because there has been no proportional increase in births of isolated cases with Down syndrome.
NASA Astrophysics Data System (ADS)
Ghanta, Sindhu; Shahini Shamsabadi, Salar; Dy, Jennifer; Wang, Ming; Birken, Ralf
2015-04-01
Around 3,000,000 million vehicle miles are annually traveled utilizing the US transportation systems alone. In addition to the road traffic safety, maintaining the road infrastructure in a sound condition promotes a more productive and competitive economy. Due to the significant amounts of financial and human resources required to detect surface cracks by visual inspection, detection of these surface defects are often delayed resulting in deferred maintenance operations. This paper introduces an automatic system for acquisition, detection, classification, and evaluation of pavement surface cracks by unsupervised analysis of images collected from a camera mounted on the rear of a moving vehicle. A Hessian-based multi-scale filter has been utilized to detect ridges in these images at various scales. Post-processing on the extracted features has been implemented to produce statistics of length, width, and area covered by cracks, which are crucial for roadway agencies to assess pavement quality. This process has been realized on three sets of roads with different pavement conditions in the city of Brockton, MA. A ground truth dataset labeled manually is made available to evaluate this algorithm and results rendered more than 90% segmentation accuracy demonstrating the feasibility of employing this approach at a larger scale.
Marini, Joan C; Forlino, Antonella; Bächinger, Hans Peter; Bishop, Nick J; Byers, Peter H; Paepe, Anne De; Fassier, Francois; Fratzl-Zelman, Nadja; Kozloff, Kenneth M; Krakow, Deborah; Montpetit, Kathleen; Semler, Oliver
2017-08-18
Skeletal deformity and bone fragility are the hallmarks of the brittle bone dysplasia osteogenesis imperfecta. The diagnosis of osteogenesis imperfecta usually depends on family history and clinical presentation characterized by a fracture (or fractures) during the prenatal period, at birth or in early childhood; genetic tests can confirm diagnosis. Osteogenesis imperfecta is caused by dominant autosomal mutations in the type I collagen coding genes (COL1A1 and COL1A2) in about 85% of individuals, affecting collagen quantity or structure. In the past decade, (mostly) recessive, dominant and X-linked defects in a wide variety of genes encoding proteins involved in type I collagen synthesis, processing, secretion and post-translational modification, as well as in proteins that regulate the differentiation and activity of bone-forming cells have been shown to cause osteogenesis imperfecta. The large number of causative genes has complicated the classic classification of the disease, and although a new genetic classification system is widely used, it is still debated. Phenotypic manifestations in many organs, in addition to bone, are reported, such as abnormalities in the cardiovascular and pulmonary systems, skin fragility, muscle weakness, hearing loss and dentinogenesis imperfecta. Management involves surgical and medical treatment of skeletal abnormalities, and treatment of other complications. More innovative approaches based on gene and cell therapy, and signalling pathway alterations, are under investigation.
7 CFR 51.1439 - Tolerances for defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... foreign material; (2) 3 percent for portions of kernels which are “dark amber” or darker color, or darker... of this tolerance may be applied to increase the tolerance for kernels which are “dark amber” or darker color, or darker than any specified lighter color classification. (b) U.S. Commercial Halves, U.S...
7 CFR 51.1439 - Tolerances for defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... foreign material; (2) 3 percent for portions of kernels which are “dark amber” or darker color, or darker... of this tolerance may be applied to increase the tolerance for kernels which are “dark amber” or darker color, or darker than any specified lighter color classification. (b) U.S. Commercial Halves, U.S...
NASA Astrophysics Data System (ADS)
Wang, Ke; Guo, Ping; Luo, A.-Li
2017-03-01
Spectral feature extraction is a crucial procedure in automated spectral analysis. This procedure starts from the spectral data and produces informative and non-redundant features, facilitating the subsequent automated processing and analysis with machine-learning and data-mining techniques. In this paper, we present a new automated feature extraction method for astronomical spectra, with application in spectral classification and defective spectra recovery. The basic idea of our approach is to train a deep neural network to extract features of spectra with different levels of abstraction in different layers. The deep neural network is trained with a fast layer-wise learning algorithm in an analytical way without any iterative optimization procedure. We evaluate the performance of the proposed scheme on real-world spectral data. The results demonstrate that our method is superior regarding its comprehensive performance, and the computational cost is significantly lower than that for other methods. The proposed method can be regarded as a new valid alternative general-purpose feature extraction method for various tasks in spectral data analysis.
Machine vision based quality inspection of flat glass products
NASA Astrophysics Data System (ADS)
Zauner, G.; Schagerl, M.
2014-03-01
This application paper presents a machine vision solution for the quality inspection of flat glass products. A contact image sensor (CIS) is used to generate digital images of the glass surfaces. The presented machine vision based quality inspection at the end of the production line aims to classify five different glass defect types. The defect images are usually characterized by very little `image structure', i.e. homogeneous regions without distinct image texture. Additionally, these defect images usually consist of only a few pixels. At the same time the appearance of certain defect classes can be very diverse (e.g. water drops). We used simple state-of-the-art image features like histogram-based features (std. deviation, curtosis, skewness), geometric features (form factor/elongation, eccentricity, Hu-moments) and texture features (grey level run length matrix, co-occurrence matrix) to extract defect information. The main contribution of this work now lies in the systematic evaluation of various machine learning algorithms to identify appropriate classification approaches for this specific class of images. In this way, the following machine learning algorithms were compared: decision tree (J48), random forest, JRip rules, naive Bayes, Support Vector Machine (multi class), neural network (multilayer perceptron) and k-Nearest Neighbour. We used a representative image database of 2300 defect images and applied cross validation for evaluation purposes.
Schimke immuno-osseous dysplasia: case report and review of 25 patients
Saraiva, J.; Dinis, A.; Resende, C.; Faria, E.; Gomes, C.; Correia, A; Gil, J.; da Fonseca, N.
1999-01-01
Immuno-osseous dysplasia is characterised by spondyloepiphyseal dysplasia, lymphopenia with defective cellular immunity, and progressive renal disease. We describe a patient with a severe form of the disease, review the features of another 24 patients, and discuss the previous classification. The differences between the two groups are not striking, and although similarities are greater between affected sibs, the same diagnosis of Schimke immuno-osseous dysplasia should apply to them all. The aetiology and physiopathology of this rare osteochondrodysplasia of presumed autosomal recessive inheritance remain unknown. Keywords: osteochondrodysplasia; immuno-osseous dysplasia; spondyloepiphyseal dysplasia; defective cellular immunity PMID:10528861
[New options in reconstructive pelvic floor surgery and surgery in urogynecology].
Martan, A
2006-12-01
The aim of this paper is to provide a brief update review of reconstructive pelvic floor surgery and surgery in urogynecology, including the application of surgical implants. Review article. Gynecological and Obstetric Clinic, 1 LF UK and VFN, Prague. Summarization, compilation and classification of recent findings, opinions and recommendations on new options in surgical procedures of reconstructive pelvic floor surgery and surgery in gynecology, with emphasis on the use of implants and their introduction into common clinical practice. From the beginning of the 1990s, the view of pelvic floor defects and urinary incontinence in women started to change significantly. The validity of De Lancey's classification of vaginal fixation into 3 basic levels was confirmed, with resulting modifications in surgical procedures. The etiology of pelvic floor defects comprises not only labor trauma or incorrectly performed previous operations (e.g. hysterectomy), but also hereditary influences and changes in the metabolism of the connective tissue. When comparing patients with or without descensus, there is a significant difference in the composition of collagen connective tissue; these findings, and the frequency of recurrence in up to 40% of patients within 3 years after the operations, resulted in the introduction of allogenous implants--meshes in the surgical treatment. These have been used for a long time in surgical treatment of abdominal wall defects, and for the above reasons the polypropylene meshes were introduced in pelvic floor defects surgery, while their safety has been proved in accordance with the principles of Evidence Based Medicine. In gynecology, these materials are already used in the laparoscopic approach to treat female stress incontinence. Pelvic floor defects occur either isolated, or combined (a defect of anterior, posterior or medial segment, or combination of all), while the patients may at the same time suffer from a stress type of urinary incontinence (SI). In surgical treatment of this type of urinary incontinence (TVT, TVT-O, TVT-S) allogenous implants--tapes--are frequently used. The results of studies suggest that one factor affecting the success of the operation using allogenous implants is the surgeon's erudition and experience in pelvic and vaginal surgery, while the long-term effect of the operation also depends on the surgical procedure involved, i.e. on the correct selection of operation methods and decision whether to use an implant or not. The effect of various operations using implants may differ as well, especially there is a difference between operations where the implant is placed freely under the bladder, and those where it is stabilized by fixing the arms of the implant under the lower arms of symphysis. Another factor to consider is the material of the implant used. Material currently recommended according to Evidence Based Medicine is: a lightweight, flexible polypropylene; and according to Amid's classification: type 1, i.e. macro-porous, monofilament material. The advantage of surgical treatment of pelvic floor defect using implants consists in a low percentage of recurrence of the descensus; there is, however, a certain risk of rejection (around 5%) and shrinking of tissues provoked by the implant.
Johnson, Sally C.; Elbogen, Eric B.
2013-01-01
Personality disorders have a complex relationship with the law that in many ways reflects their complexity within the clinical and research communities. This paper addresses expert testimony about personality disorders, outlines how personality disorders are assessed in forensic cases, and describes how personality disorders are viewed in different legal contexts. Reasons are identified why personality disorders are not generally accepted as significant mental illness within the legal system, including high incidence of personality dysfunction in criminal populations, frequent comorbidity of personality disorders making it difficult to determine direct causation, and difficulty determining where on a continuum personality traits should be defined as illness (or not). In summary, the legal system, to a significant degree, mirrors the clinical conception of personality disorders as not severe mental diseases or defects, not likely to change, and most often, under volitional control. PMID:24174894
Johnson, Sally C; Elbogen, Eric B
2013-06-01
Personality disorders have a complex relationship with the law that in many ways reflects their complexity within the clinical and research communities. This paper addresses expert testimony about personality disorders, outlines how personality disorders are assessed in forensic cases, and describes how personality disorders are viewed in different legal contexts. Reasons are identified why personality disorders are not generally accepted as significant mental illness within the legal system, including high incidence of personality dysfunction in criminal populations, frequent comorbidity of personality disorders making it difficult to determine direct causation, and difficulty determining where on a continuum personality traits should be defined as illness (or not). In summary, the legal system, to a significant degree, mirrors the clinical conception of personality disorders as not severe mental diseases or defects, not likely to change, and most often, under volitional control.
Case report: waardenburg syndrome.
Dumayas, Grace Lea; Capó-Aponte, José E
2015-03-01
A case of Waardenburg syndrome type 1 is described and relevant literature is reviewed to raise awareness about this rare syndrome, including the classification of each subtype and the differentiating clinical manifestations. A 44-year-old African-American female presented for a routine evaluation with hearing loss, dystopia canthorum (W index = 2.74), and almost complete gray hair. In addition, she presented with heterochromia irides, different fundus pigmentation between eyes. The patient did not have any upper limbs defect, cranial skeletal abnormalities, or intestinal disorders. Facial abnormalities and a white forelock are prominent features difficult to overlook during a routine ophthalmological examination. A careful medical history in patients with suspected Waardenburg syndrome is important to accurately classify this rare condition and to identify potential systemic implications associated to each subtype. The associated systemic complications can be addressed and managed through referral to the appropriate subspecialties. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
USDA-ARS?s Scientific Manuscript database
It is challenging to achieve rapid and accurate processing of large amounts of hyperspectral image data. This research was aimed to develop a novel classification method by employing deep feature representation with the stacked sparse auto-encoder (SSAE) and the SSAE combined with convolutional neur...
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Definitions § 51.1175... segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or...
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Definitions § 51.1175... segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or...
7 CFR 52.1008 - Absence of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... PROCESSED FOOD PRODUCTS 1 United States Standards for Grades of Dates Factors of Quality § 52.1008 Absence.... Dates that fall into this classification shall not be graded above U.S. Grade B or U.S. Choice or U.S. Grade B (Dry) or U.S. Choice (Dry), whichever is applicable, regardless of the total score for the...
7 CFR 51.2340 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... or discoloration of the flesh extends more than 1/16 inch (1.6 mm) in depth When surface of fruit is indented and discoloration of the flesh extends deeper than 1/8 inch (3.2 mm), or causing slight discoloration exceeding the area of a circle 3/8 inch (9.5 mm) in diameter, or lesser bruises aggregating an...
7 CFR 51.2340 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... or discoloration of the flesh extends more than 1/16 inch (1.6 mm) in depth When surface of fruit is indented and discoloration of the flesh extends deeper than 1/8 inch (3.2 mm), or causing slight discoloration exceeding the area of a circle 3/8 inch (9.5 mm) in diameter, or lesser bruises aggregating an...
Connected component analysis of review-SEM images for sub-10nm node process verification
NASA Astrophysics Data System (ADS)
Halder, Sandip; Leray, Philippe; Sah, Kaushik; Cross, Andrew; Parisi, Paolo
2017-03-01
Analysis of hotspots is becoming more and more critical as we scale from node to node. To define true process windows at sub-14 nm technology nodes, often defect inspections are being included to weed out design weak spots (often referred to as hotspots). Defect inspection sub 28 nm nodes is a two pass process. Defect locations identified by optical inspection tools need to be reviewed by review-SEM's to understand exactly which feature is failing in the region flagged by the optical tool. The images grabbed by the review-SEM tool are used for classification but rarely for quantification. The goal of this paper is to see if the thousands of review-SEM images which are existing can be used for quantification and further analysis. More specifically we address the SEM quantification problem with connected component analysis.
Congenital heart defects: the 10-year experience at a single center.
Aydin, Emine; Aypar, Ebru; Oktem, Ahmet; Ozyuncu, Ozgur; Yurdakok, Murat; Guvener, Murat; Demircin, Metin; Beksac, M Sinan
2018-06-18
We aimed to evaluate congenital heart disease (CHD) cases according to EUROCAT subgroup classification that were diagnosed during the prenatal period in our center. CHDs that were prenatally diagnosed using ultrasonography and confirmed by fetal echocardiography were reviewed over a 10-year period. Subgroup classification was finalized at the post-partum period in terms of the EUROCAT guide 1.3. Congenital heart defect subtypes and obstetric outcomes (gestational week at delivery, birth weight, gender, extracardiac structural abnormalities, karyotype results if performed) were analyzed. The data of 180 cases with CHD was examined. Left ventricular outflow tract obstruction (LVOT) was the most common CHD subtype (57/180; 31.6%), which included 48, five, and four cases of hypoplastic left heart syndrome (HLHS), coarctation of the aorta, and aortic valve atresia/stenosis, respectively. Eighteen pregnancies were terminated; the most common CHD subtype among patients of terminated pregnancies was hypoplastic left heart syndrome (HLHS) (n = 7, 38.8%). The most common extracardiac malformations were a single umbilical artery, esophageal atresia, and situs inversus in our study group. Eighteen of the 96 (18.75%) neonates with CHD died during the neonatal period. The most common CHD subtype was HLHS (7/18; 38%) among the newborns who died after birth. Prenatal diagnosis of a CHD and subgroup classification is very important for clinical decision making, including prenatal management, recommendations for termination of the pregnancy, postnatal management of the patient, and for early referral to pediatric cardiology and cardiovascular surgery centers.
Cerebro-costo-mandibular syndrome: prognosis and proposal for classification.
Nagasawa, Hiroyuki; Yamamoto, Yutaka; Kohno, Yoshinori
2010-09-01
Cerebro-costo-mandibular syndrome (CCMS) is a very rare syndrome characterized by micrognathia and posterior rib gap, with a poor prognosis. To date, only 75 cases have been reported worldwide. The overall survival rate for patients with this disorder has not been reported, and a classification of the patients on the basis of the prognosis is not yet available. The present study analyzed the figures and prognoses of past patients and documented a new case of CCMS. Formerly published case reports and personal communications were used to reveal the prognosis and classification of CCMS. The occurrence ratios of rib gap defects and of missing ribs were examined. Patients were divided into the following three groups according to their life span: lethal type, where the patients died before 1 month; severe type, where the patients lived for 1-12 months; and mild type, where they survived for more than 1 year. A comparison was made of the number of rib gaps, missing ribs, and the rib gap ratio (defined as the number of rib gaps divided by the number of all existing ribs) among these three groups. A significant difference in the number of rib defects between the lethal type and other types was noted. Short life span of severe type patients, compared to mild type, was attributed to their subjection to severe respiratory infection. CCMS can be classified into three categories--lethal, severe, and mild--according to the severity of the symptoms and prognosis.
Simulation based mask defect repair verification and disposition
NASA Astrophysics Data System (ADS)
Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo
2009-10-01
As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple optical model can be used to get simulated aerial image intensity in the AOI. With built-in contour analysis functions, the SMDD software can easily compare the contour (or intensity) differences between defect pattern and normal pattern. With user provided judging criteria, this software can be easily disposition the defect based on contour comparison. In addition, process sensitivity properties, like MEEF and NILS, can be readily obtained in the AOI with a lithography model, which will make mask defect disposition criteria more intelligent.
Flexible mobile robot system for smart optical pipe inspection
NASA Astrophysics Data System (ADS)
Kampfer, Wolfram; Bartzke, Ralf; Ziehl, Wolfgang
1998-03-01
Damages of pipes can be inspected and graded by TV technology available on the market. Remotely controlled vehicles carry a TV-camera through pipes. Thus, depending on the experience and the capability of the operator, diagnosis failures can not be avoided. The classification of damages requires the knowledge of the exact geometrical dimensions of the damages such as width and depth of cracks, fractures and defect connections. Within the framework of a joint R&D project a sensor based pipe inspection system named RODIAS has been developed with two partners from industry and research institute. It consists of a remotely controlled mobile robot which carries intelligent sensors for on-line sewerage inspection purpose. The sensor is based on a 3D-optical sensor and a laser distance sensor. The laser distance sensor is integrated in the optical system of the camera and can measure the distance between camera and object. The angle of view can be determined from the position of the pan and tilt unit. With coordinate transformations it is possible to calculate the spatial coordinates for every point of the video image. So the geometry of an object can be described exactly. The company Optimess has developed TriScan32, a special software for pipe condition classification. The user can start complex measurements of profiles, pipe displacements or crack widths simply by pressing a push-button. The measuring results are stored together with other data like verbal damage descriptions and digitized images in a data base.
Development of an automated ultrasonic testing system
NASA Astrophysics Data System (ADS)
Shuxiang, Jiao; Wong, Brian Stephen
2005-04-01
Non-Destructive Testing is necessary in areas where defects in structures emerge over time due to wear and tear and structural integrity is necessary to maintain its usability. However, manual testing results in many limitations: high training cost, long training procedure, and worse, the inconsistent test results. A prime objective of this project is to develop an automatic Non-Destructive testing system for a shaft of the wheel axle of a railway carriage. Various methods, such as the neural network, pattern recognition methods and knowledge-based system are used for the artificial intelligence problem. In this paper, a statistical pattern recognition approach, Classification Tree is applied. Before feature selection, a thorough study on the ultrasonic signals produced was carried out. Based on the analysis of the ultrasonic signals, three signal processing methods were developed to enhance the ultrasonic signals: Cross-Correlation, Zero-Phase filter and Averaging. The target of this step is to reduce the noise and make the signal character more distinguishable. Four features: 1. The Auto Regressive Model Coefficients. 2. Standard Deviation. 3. Pearson Correlation 4. Dispersion Uniformity Degree are selected. And then a Classification Tree is created and applied to recognize the peak positions and amplitudes. Searching local maximum is carried out before feature computing. This procedure reduces much computation time in the real-time testing. Based on this algorithm, a software package called SOFRA was developed to recognize the peaks, calibrate automatically and test a simulated shaft automatically. The automatic calibration procedure and the automatic shaft testing procedure are developed.
Automatic OPC repair flow: optimized implementation of the repair recipe
NASA Astrophysics Data System (ADS)
Bahnas, Mohamed; Al-Imam, Mohamed; Word, James
2007-10-01
Virtual manufacturing that is enabled by rapid, accurate, full-chip simulation is a main pillar in achieving successful mask tape-out in the cutting-edge low-k1 lithography. It facilitates detecting printing failures before a costly and time-consuming mask tape-out and wafer print occur. The OPC verification step role is critical at the early production phases of a new process development, since various layout patterns will be suspected that they might to fail or cause performance degradation, and in turn need to be accurately flagged to be fed back to the OPC Engineer for further learning and enhancing in the OPC recipe. At the advanced phases of the process development, there is much less probability of detecting failures but still the OPC Verification step act as the last-line-of-defense for the whole RET implemented work. In recent publication the optimum approach of responding to these detected failures was addressed, and a solution was proposed to repair these defects in an automated methodology and fully integrated and compatible with the main RET/OPC flow. In this paper the authors will present further work and optimizations of this Repair flow. An automated analysis methodology for root causes of the defects and classification of them to cover all possible causes will be discussed. This automated analysis approach will include all the learning experience of the previously highlighted causes and include any new discoveries. Next, according to the automated pre-classification of the defects, application of the appropriate approach of OPC repair (i.e. OPC knob) on each classified defect location can be easily selected, instead of applying all approaches on all locations. This will help in cutting down the runtime of the OPC repair processing and reduce the needed number of iterations to reach the status of zero defects. An output report for existing causes of defects and how the tool handled them will be generated. The report will with help further learning and facilitate the enhancement of the main OPC recipe. Accordingly, the main OPC recipe can be more robust, converging faster and probably in a fewer number of iterations. This knowledge feedback loop is one of the fruitful benefits of the Automatic OPC Repair flow.
Spencer, Brian A; Dolinskas, Carol A; Seymour, Peter A; Thomas, Stephen J; Abboud, Joseph A
2013-09-01
The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Bashiri, Azadeh; Shahmoradi, Leila; Beigy, Hamid; Savareh, Behrouz A; Nosratabadi, Masood; N Kalhori, Sharareh R; Ghazisaeedi, Marjan
2018-06-01
Quantitative EEG gives valuable information in the clinical evaluation of psychological disorders. The purpose of the present study is to identify the most prominent features of quantitative electroencephalography (QEEG) that affect attention and response control parameters in children with attention deficit hyperactivity disorder. The QEEG features and the Integrated Visual and Auditory-Continuous Performance Test ( IVA-CPT) of 95 attention deficit hyperactivity disorder subjects were preprocessed by Independent Evaluation Criterion for Binary Classification. Then, the importance of selected features in the classification of desired outputs was evaluated using the artificial neural network. Findings uncovered the highest rank of QEEG features in each IVA-CPT parameters related to attention and response control. Using the designed model could help therapists to determine the existence or absence of defects in attention and response control relying on QEEG.
Information support of monitoring of technical condition of buildings in construction risk area
NASA Astrophysics Data System (ADS)
Skachkova, M. E.; Lepihina, O. Y.; Ignatova, V. V.
2018-05-01
The paper presents the results of the research devoted to the development of a model of information support of monitoring buildings technical condition; these buildings are located in the construction risk area. As a result of the visual and instrumental survey, as well as the analysis of existing approaches and techniques, attributive and cartographic databases have been created. These databases allow monitoring defects and damages of buildings located in a 30-meter risk area from the object under construction. The classification of structures and defects of these buildings under survey is presented. The functional capabilities of the developed model and the field of it practical applications are determined.
NASA Technical Reports Server (NTRS)
Sastri, Sankar
1990-01-01
The purpose of this experiment is to familiarize the student with magnetic particle inspection and relate it to classification of various defects. Magnetic particle inspection is a method of detecting the presence of cracks, laps, tears, inclusions, and similar discontinuities in ferromagnetic materials such as iron and steel. This method will most clearly show defects that are perpendicular to the magnetic field. The Magnaglo method uses a liquid which is sprayed on the workpiece to be inspected, and the part is magnetized at the same time. The workpiece is then viewed under a black light, and the presence of discontinuity is shown by the formation of a bright indication formed by the magnetic particles over the discontinuity. The equipment and experimental procedures are described.
NASA Astrophysics Data System (ADS)
Madrigal, Carlos A.; Restrepo, Alejandro; Branch, John W.
2016-09-01
3D reconstruction of small objects is used in applications of surface analysis, forensic analysis and tissue reconstruction in medicine. In this paper, we propose a strategy for the 3D reconstruction of small objects and the identification of some superficial defects. We applied a technique of projection of structured light patterns, specifically sinusoidal fringes and an algorithm of phase unwrapping. A CMOS camera was used to capture images and a DLP digital light projector for synchronous projection of the sinusoidal pattern onto the objects. We implemented a technique based on a 2D flat pattern as calibration process, so the intrinsic and extrinsic parameters of the camera and the DLP were defined. Experimental tests were performed in samples of artificial teeth, coal particles, welding defects and surfaces tested with Vickers indentation. Areas less than 5cm were studied. The objects were reconstructed in 3D with densities of about one million points per sample. In addition, the steps of 3D description, identification of primitive, training and classification were implemented to recognize defects, such as: holes, cracks, roughness textures and bumps. We found that pattern recognition strategies are useful, when quality supervision of surfaces has enough quantities of points to evaluate the defective region, because the identification of defects in small objects is a demanding activity of the visual inspection.
Chu, Stephen J; Sarnachiaro, Guido O; Hochman, Mark N; Tarnow, Dennis P
2015-01-01
Immediate implant therapy involving implants placed into intact Type 1 extraction sockets has become a consistent clinical technique. The classification of Type 2 extraction sockets, where the mucosal tissues are present but there is a midfacial osseous dehiscence defect, has been described according to the extent of the buccal bone plate absence. The literature has offered different techniques in the treatment of Type 2 sockets; however, the extent of the defect has never been defined or delineated. In this article, the authors describe a subclassification of Type 2 sockets: Type 2A presents with a dehiscence defect roughly 5 mm to 6 mm from the free gingival margin (FGM) involving the coronal one-third of the labial bone plate; Type 2B presents with a dehiscence defect involving the middle one-third of the labial plate, approximately 7 mm to 9 mm from the FGM; and in Type 2C the dehiscence defect involves the apical one-third of the labial osseous plate roughly 10 mm or greater from the FGM. The authors also offer a protocol and technique employing immediate implant placement, guided bone regeneration, and bone graft containment with a custom two-piece healing abutment that can lead to consistent and satisfactory clinical outcomes in low-smile-line patients. The treatment protocol and sequence is outlined in a clinical case presentation involving a Type 2B socket.
Gutierrez-Quintana, Rodrigo; Guevar, Julien; Stalin, Catherine; Faller, Kiterie; Yeamans, Carmen; Penderis, Jacques
2014-01-01
Congenital vertebral malformations are common in brachycephalic "screw-tailed" dog breeds such as French bulldogs, English bulldogs, Boston terriers, and pugs. The aim of this retrospective study was to determine whether a radiographic classification scheme developed for use in humans would be feasible for use in these dog breeds. Inclusion criteria were hospital admission between September 2009 and April 2013, neurologic examination findings available, diagnostic quality lateral and ventro-dorsal digital radiographs of the thoracic vertebral column, and at least one congenital vertebral malformation. Radiographs were retrieved and interpreted by two observers who were unaware of neurologic status. Vertebral malformations were classified based on a classification scheme modified from a previous human study and a consensus of both observers. Twenty-eight dogs met inclusion criteria (12 with neurologic deficits, 16 with no neurologic deficits). Congenital vertebral malformations affected 85/362 (23.5%) of thoracic vertebrae. Vertebral body formation defects were the most common (butterfly vertebrae 6.6%, ventral wedge-shaped vertebrae 5.5%, dorsal hemivertebrae 0.8%, and dorso-lateral hemivertebrae 0.5%). No lateral hemivertebrae or lateral wedge-shaped vertebrae were identified. The T7 vertebra was the most commonly affected (11/28 dogs), followed by T8 (8/28 dogs) and T12 (8/28 dogs). The number and type of vertebral malformations differed between groups (P = 0.01). Based on MRI, dorsal, and dorso-lateral hemivertebrae were the cause of spinal cord compression in 5/12 (41.6%) of dogs with neurologic deficits. Findings indicated that a modified human radiographic classification system of vertebral malformations is feasible for use in future studies of brachycephalic "screw-tailed" dogs. © 2014 American College of Veterinary Radiology.
Qu, Jinfeng; Velaga, Swetha Bindu; Hariri, Amir H; Nittala, Muneeswar Gupta; Sadda, Srinivas
2017-08-22
The junctional zone at the border of areas of geographic atrophy (GA) in eyes with nonneovascular age-related macular degeneration is an important target region for future therapeutic strategies. The goal of this study was to perform a detailed classification and quantitative characterization of the junctional zone using spectral domain optical coherence tomography. Spectral domain optical coherence tomography volume cube scans (Spectralis OCT, 1024 × 37, Automatic Real Time > 9) were obtained from 15 eyes of 11 patients with GA because of nonneovascular age-related macular degeneration. Volume optical coherence tomography data were imported into previously described validated grading software (3D-OCTOR), and manual segmentation of the retinal pigment epithelium (RPE) and photoreceptor layers was performed on all B-scans (total of 555). Retinal pigment epithelium and photoreceptor defect maps were produced for each case. The borders of the photoreceptor defect area and RPE defect area were delineated individually on separate annotation layers. The two outlines were then superimposed to compare the areas of overlap and nonoverlap. The perimeter of the RPE defect area was calculated by the software in pixels. The superimposed outline of the photoreceptor defect area and the RPE defect area was scrutinized to classify the overlap configuration of the junctional zone into one of three categories: Type 0, exact correspondence between the edge of the RPE defect and photoreceptor defect; Type 1, loss of photoreceptors outside and beyond the edge of the RPE defect; Type 2, preservation of photoreceptors beyond the edge of the RPE defect. The relative proportion of the various border configurations was expressed as a percentage of the perimeter of the RPE defect. Each configuration was then classified into four subgroups according to irregularity of the RPE band and the presence of debris. Fifteen eyes of 11 patients (mean age: 79.3 ± 4.3 years; range: 79-94 years) were included in this study. Seventeen GA lesions were analyzed. Two hundred and thirty-two B-scans were found to pass through the GA lesions, yielding 612 individual GA borders which were separately analyzed and classified. The mean area of the RPE defect was 4.0 ± 4.4 mm, which was significantly smaller than that of the photoreceptor defect which measured 4.4 ± 4.1 mm (paired t test, P = 0.037). On average, 18.0 ± 9.6% (range, 2.3-36.6%) of the junctional zone was of the Type 0 configuration, 57.3 ± 19.0% (range, 21.3-96.8%) was Type 1, and 24.7 ± 18.0% (range, 0.9-64.4%) was Type 2. Type 1 was more prevalent than Type 0 and 2 (analysis of variance, P = 0.000). Debris was present at the margin of the defect in 24.3% (149 of 612) of all assessed junctional zones; 20.0% (14 of 70) of Type 0 junctions, 28.7% (120 of 418) of Type 1, and 12.1% (15 of 124) of Type 2. Debris was more common in Type 1 than Type 2 junctions (P < 0.001). Retinal pigment epithelial irregularity was present at the margin of the defect in 34.8% (213 of 612) of all assessed junctional zones; 52.9% (37 of 70) of Type 0 junctions, 38.0% (159 of 418) of Type 1, and 13.7% (17 of 124) of Type 2. Retinal pigment epithelial irregularity was present more often at Type 0 and Type 1 than at Type 2 junctions (P < 0.001 for both). The size of the optical coherence tomography-visible RPE and photoreceptor defect in GA lesions differ significantly. There were significant areas where the photoreceptor outer segments were preserved despite the absence of visible RPE cells, and also areas of photoreceptor outer segment loss despite apparent RPE preservation. These findings have implications for development of therapeutic strategies, particularly cell-replacement approaches.
Creating a Canonical Scientific and Technical Information Classification System for NCSTRL+
NASA Technical Reports Server (NTRS)
Tiffany, Melissa E.; Nelson, Michael L.
1998-01-01
The purpose of this paper is to describe the new subject classification system for the NCSTRL+ project. NCSTRL+ is a canonical digital library (DL) based on the Networked Computer Science Technical Report Library (NCSTRL). The current NCSTRL+ classification system uses the NASA Scientific and Technical (STI) subject classifications, which has a bias towards the aerospace, aeronautics, and engineering disciplines. Examination of other scientific and technical information classification systems showed similar discipline-centric weaknesses. Traditional, library-oriented classification systems represented all disciplines, but were too generalized to serve the needs of a scientific and technically oriented digital library. Lack of a suitable existing classification system led to the creation of a lightweight, balanced, general classification system that allows the mapping of more specialized classification schemes into the new framework. We have developed the following classification system to give equal weight to all STI disciplines, while being compact and lightweight.
Angle-Beam Shear Wave Scattering from Buried Crack-like Defects in Bonded Specimens (Postprint)
2017-02-01
wavenumber filtering and spatial windowing is proposed and implemented as an alternative approach to quantify scattering from damage. 15. SUBJECT...TERMS Backscattering . Ultrasonography . Spatial filtering . Ultrasonic scattering . Scattering measurement 16. SECURITY CLASSIFICATION OF: 17...of frequency- wavenumber filtering and spatial windowing is proposed and implemented as an alternative approach to quantify scattering from damage
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... diameter, caused by scale Aggregating more than 1/3 of the surface, caused by scale. Oil spots Aggregating... surface. Sprouting More than six seeds have sprouts of more than 1/4 inch (6.4 mm) in length, or more than 3 seeds with sprouts over 3/4 inch (19.1 mm) in length More than six seeds have sprouts of more than...
Some technical aspects of trimming lumber in the planing mill
Peter Koch
1952-01-01
This paper discusses four classes of lumber timming machines applicable to the planning mill. The classification is made according to function as follows: Irregularity or defect removal to increase the value of residual portion. Double end trimming to a length standard acceptable by the trade, trimming to specified length of the higher grades of stock after it has been...
7 CFR 51.2340 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... flesh extends more than 1/16 inch (1.6 mm) in depth When surface of fruit is indented and discoloration of the flesh extends deeper than 1/8 inch (3.2 mm), or causing slight discoloration exceeding the area of a circle 3/8 inch (9.5 mm) in diameter, or lesser bruises aggregating an area of a circle 3/8...
7 CFR 51.2340 - Classification of defects.
Code of Federal Regulations, 2010 CFR
2010-01-01
... flesh extends more than 1/16 inch (1.6 mm) in depth When surface of fruit is indented and discoloration of the flesh extends deeper than 1/8 inch (3.2 mm), or causing slight discoloration exceeding the area of a circle 3/8 inch (9.5 mm) in diameter, or lesser bruises aggregating an area of a circle 3/8...
7 CFR 51.2340 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... flesh extends more than 1/16 inch (1.6 mm) in depth When surface of fruit is indented and discoloration of the flesh extends deeper than 1/8 inch (3.2 mm), or causing slight discoloration exceeding the area of a circle 3/8 inch (9.5 mm) in diameter, or lesser bruises aggregating an area of a circle 3/8...
[Principles of management of periprosthetic fractures].
Röderer, G; Gebhard, F; Scola, A
2016-03-01
The increasing numbers of primary total hip and knee replacements have subsequently led to growing rates of periprosthetic fractures. In many cases geriatric patients with osteopenia or osteoporotic bone quality are affected. The goal of treatment is the retention or reconstruction of joint function using open reduction and internal fixation or a revision prosthesis. The aim of this article is a description of the basic principles of treatment of periprosthetic fractures of the lower extremities. An exact description of the fracture using current classification systems with imaging diagnostics is mandatory. This also includes an assessment of the stability of the prosthesis. In the case of a stable prosthesis and a good bone stock open reduction and internal fixation should be performed. In these cases locking plates are standard procedure. If fracture reduction is possible minimally invasive procedures can be performed which help to reduce the surgical trauma and accelerate rehabilitation. If the prosthesis is loose it has to be exchanged for a revision implant. If vast bony defects result they can be augmented using wedges. Conservative treatment plays only a subordinate role in selected cases. Periprosthetic fractures show an increasing incidence and occur more frequently in the geriatric patient population. Due to comorbidities and poor bone quality surgical treatment is a challenge. The fracture must be exactly classified using the appropriate classification system in order to clarify if the prosthesis can be retained or if it has to be exchanged.
Two-dimensional PSF prediction of multiple-reflection optical systems with rough surfaces
NASA Astrophysics Data System (ADS)
Tayabaly, Kashmira; Spiga, Daniele; Sironi, Giorgia; Pareschi, Giovani; Lavagna, Michele
2016-09-01
The focusing accuracy in reflective optical systems, usually expressed in terms of the Point Spread Function (PSF) is chiefly determined by two factors: the deviation of the mirror shape from the nominal design and the surface finishing. While the effects of the former are usually well described by the geometrical optics, the latter is diffractive/interferential in nature and determined by a distribution of defects that cover several decades in the lateral scale (from a few millimeters to a few microns). Clearly, reducing the level of scattered light is crucial to improve the focusing of the collected radiation, particularly for astronomical telescopes that aim to detect faint light signals from our Universe. Telescopes are typically arranged in multiple reflections configuration and the behavior of the multiply-scattered radiation becomes difficult to predict and control. Also it is difficult to disentangle the effect of surface scattering from the PSF degradation caused by the shape deformation of the optical elements. This paper presents a simple and unifying method for evaluating the contribution of optical surfaces defects to the two-dimensional PSF of a multi-reflections system, regardless of the classification of a spectral range as "geometry" or "roughness". This method, entirely based on Huygens-Fresnel principle in the far-field approximation, was already applied in grazing-incidence X-ray mirrors and experimentally validated for a single reflection system, accounting for the real surface topography of the optics. In this work we show the extension of this formalism to a double reflection system and introducing real microroughness data. The formalism is applied to a MAGIC-I panel mirror that was fully characterized, allowing us to predict the PSF and the validation with real measurements of the double reflection ASTRI telescope, a prototype of CTA-SST telescope.
Alam, Daniel; Ali, Yaseen; Klem, Christopher; Coventry, Daniel
2016-11-01
Orbito-malar reconstruction after oncological resection represents one of the most challenging facial reconstructive procedures. Until the last few decades, rehabilitation was typically prosthesis based with a limited role for surgery. The advent of microsurgical techniques allowed large-volume tissue reconstitution from a distant donor site, revolutionizing the potential approaches to these defects. The authors report a novel surgery-based algorithm and a classification scheme for complete midface reconstruction with a foundation in the Gillies principles of like-to-like reconstruction and with a significant role of computer-aided virtual planning. With this approach, the authors have been able to achieve significantly better patient outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.
Concrete Condition Assessment Using Impact-Echo Method and Extreme Learning Machines
Zhang, Jing-Kui; Yan, Weizhong; Cui, De-Mi
2016-01-01
The impact-echo (IE) method is a popular non-destructive testing (NDT) technique widely used for measuring the thickness of plate-like structures and for detecting certain defects inside concrete elements or structures. However, the IE method is not effective for full condition assessment (i.e., defect detection, defect diagnosis, defect sizing and location), because the simple frequency spectrum analysis involved in the existing IE method is not sufficient to capture the IE signal patterns associated with different conditions. In this paper, we attempt to enhance the IE technique and enable it for full condition assessment of concrete elements by introducing advanced machine learning techniques for performing comprehensive analysis and pattern recognition of IE signals. Specifically, we use wavelet decomposition for extracting signatures or features out of the raw IE signals and apply extreme learning machine, one of the recently developed machine learning techniques, as classification models for full condition assessment. To validate the capabilities of the proposed method, we build a number of specimens with various types, sizes, and locations of defects and perform IE testing on these specimens in a lab environment. Based on analysis of the collected IE signals using the proposed machine learning based IE method, we demonstrate that the proposed method is effective in performing full condition assessment of concrete elements or structures. PMID:27023563
Automatic crack detection and classification method for subway tunnel safety monitoring.
Zhang, Wenyu; Zhang, Zhenjiang; Qi, Dapeng; Liu, Yun
2014-10-16
Cracks are an important indicator reflecting the safety status of infrastructures. This paper presents an automatic crack detection and classification methodology for subway tunnel safety monitoring. With the application of high-speed complementary metal-oxide-semiconductor (CMOS) industrial cameras, the tunnel surface can be captured and stored in digital images. In a next step, the local dark regions with potential crack defects are segmented from the original gray-scale images by utilizing morphological image processing techniques and thresholding operations. In the feature extraction process, we present a distance histogram based shape descriptor that effectively describes the spatial shape difference between cracks and other irrelevant objects. Along with other features, the classification results successfully remove over 90% misidentified objects. Also, compared with the original gray-scale images, over 90% of the crack length is preserved in the last output binary images. The proposed approach was tested on the safety monitoring for Beijing Subway Line 1. The experimental results revealed the rules of parameter settings and also proved that the proposed approach is effective and efficient for automatic crack detection and classification.
Automatic Crack Detection and Classification Method for Subway Tunnel Safety Monitoring
Zhang, Wenyu; Zhang, Zhenjiang; Qi, Dapeng; Liu, Yun
2014-01-01
Cracks are an important indicator reflecting the safety status of infrastructures. This paper presents an automatic crack detection and classification methodology for subway tunnel safety monitoring. With the application of high-speed complementary metal-oxide-semiconductor (CMOS) industrial cameras, the tunnel surface can be captured and stored in digital images. In a next step, the local dark regions with potential crack defects are segmented from the original gray-scale images by utilizing morphological image processing techniques and thresholding operations. In the feature extraction process, we present a distance histogram based shape descriptor that effectively describes the spatial shape difference between cracks and other irrelevant objects. Along with other features, the classification results successfully remove over 90% misidentified objects. Also, compared with the original gray-scale images, over 90% of the crack length is preserved in the last output binary images. The proposed approach was tested on the safety monitoring for Beijing Subway Line 1. The experimental results revealed the rules of parameter settings and also proved that the proposed approach is effective and efficient for automatic crack detection and classification. PMID:25325337
NASA Astrophysics Data System (ADS)
Lin, Y.; Chen, X.
2016-12-01
Land cover classification systems used in remote sensing image data have been developed to meet the needs for depicting land covers in scientific investigations and policy decisions. However, accuracy assessments of a spate of data sets demonstrate that compared with the real physiognomy, each of the thematic map of specific land cover classification system contains some unavoidable flaws and unintended deviation. This work proposes a web-based land cover classification system, an integrated prototype, based on an ontology model of various classification systems, each of which is assigned the same weight in the final determination of land cover type. Ontology, a formal explication of specific concepts and relations, is employed in this prototype to build up the connections among different systems to resolve the naming conflicts. The process is initialized by measuring semantic similarity between terminologies in the systems and the search key to produce certain set of satisfied classifications, and carries on through searching the predefined relations in concepts of all classification systems to generate classification maps with user-specified land cover type highlighted, based on probability calculated by votes from data sets with different classification system adopted. The present system is verified and validated by comparing the classification results with those most common systems. Due to full consideration and meaningful expression of each classification system using ontology and the convenience that the web brings with itself, this system, as a preliminary model, proposes a flexible and extensible architecture for classification system integration and data fusion, thereby providing a strong foundation for the future work.
Gür Güngör, Sirel; Akman, Ahmet; Sarıgül Sezenöz, Almila; Tanrıaşıkı, Gülşah
2016-12-01
The presence of retinal nerve fiber layer (RNFL) split bundles was recently described in normal eyes scanned using scanning laser polarimetry and by histologic studies. Split bundles may resemble RNFL loss in healthy eyes. The aim of our study was to determine the prevalence of nerve fiber layer split bundles in healthy people. We imaged 718 eyes of 359 healthy persons with the spectral domain optical coherence tomography in this cross-sectional study. All eyes had intraocular pressure of 21 mmHg or less, normal appearance of the optic nerve head, and normal visual fields (Humphrey Field Analyzer 24-2 full threshold program). In our study, a bundle was defined as 'split' when there is localized defect not resembling a wedge defect in the RNFL deviation map with a symmetrically divided RNFL appearance on the RNFL thickness map. The classification was performed by two independent observers who used an identical set of reference examples to standardize the classification. Inter-observer consensus was reached in all cases. Bilateral superior split bundles were seen in 19 cases (5.29%) and unilateral superior split was observed in 15 cases (4.16%). In 325 cases (90.52%) there was no split bundle. Split nerve fiber layer bundles, in contrast to single nerve fiber layer bundles, are not common findings in healthy eyes. In eyes with normal optic disc appearance, especially when a superior RNFL defect is observed in RNFL deviation map, the RNLF thickness map and graphs should also be examined for split nerve fiber layer bundles.
42 CFR 412.620 - Patient classification system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Patient classification system. 412.620 Section 412... Inpatient Rehabilitation Hospitals and Rehabilitation Units § 412.620 Patient classification system. (a) Classification methodology. (1) A patient classification system is used to classify patients in inpatient...
42 CFR 412.620 - Patient classification system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Patient classification system. 412.620 Section 412... Inpatient Rehabilitation Hospitals and Rehabilitation Units § 412.620 Patient classification system. (a) Classification methodology. (1) A patient classification system is used to classify patients in inpatient...
Intra- and Interobserver Reliability of Three Classification Systems for Hallux Rigidus.
Dillard, Sarita; Schilero, Christina; Chiang, Sharon; Pham, Peter
2018-04-18
There are over ten classification systems currently used in the staging of hallux rigidus. This results in confusion and inconsistency with radiographic interpretation and treatment. The reliability of hallux rigidus classification systems has not yet been tested. The purpose of this study was to evaluate intra- and interobserver reliability using three commonly used classifications for hallux rigidus. Twenty-one plain radiograph sets were presented to ten ACFAS board-certified foot and ankle surgeons. Each physician classified each radiograph based on clinical experience and knowledge according to the Regnauld, Roukis, and Hattrup and Johnson classification systems. The two-way mixed single-measure consistency intraclass correlation was used to calculate intra- and interrater reliability. The intrarater reliability of individual sets for the Roukis and Hattrup and Johnson classification systems was "fair to good" (Roukis, 0.62±0.19; Hattrup and Johnson, 0.62±0.28), whereas the intrarater reliability of individual sets for the Regnauld system bordered between "fair to good" and "poor" (0.43±0.24). The interrater reliability of the mean classification was "excellent" for all three classification systems. Conclusions Reliable and reproducible classification systems are essential for treatment and prognostic implications in hallux rigidus. In our study, Roukis classification system had the best intrarater reliability. Although there are various classification systems for hallux rigidus, our results indicate that all three of these classification systems show reliability and reproducibility.
Polydispersity-driven topological defects as order-restoring excitations.
Yao, Zhenwei; Olvera de la Cruz, Monica
2014-04-08
The engineering of defects in crystalline matter has been extensively exploited to modify the mechanical and electrical properties of many materials. Recent experiments on manipulating extended defects in graphene, for example, show that defects direct the flow of electric charges. The fascinating possibilities offered by defects in two dimensions, known as topological defects, to control material properties provide great motivation to perform fundamental investigations to uncover their role in various systems. Previous studies mostly focus on topological defects in 2D crystals on curved surfaces. On flat geometries, topological defects can be introduced via density inhomogeneities. We investigate here topological defects due to size polydispersity on flat surfaces. Size polydispersity is usually an inevitable feature of a large variety of systems. In this work, simulations show well-organized induced topological defects around an impurity particle of a wrong size. These patterns are not found in systems of identical particles. Our work demonstrates that in polydispersed systems topological defects play the role of restoring order. The simulations show a perfect hexagonal lattice beyond a small defective region around the impurity particle. Elasticity theory has demonstrated an analogy between the elementary topological defects named disclinations to electric charges by associating a charge to a disclination, whose sign depends on the number of its nearest neighbors. Size polydispersity is shown numerically here to be an essential ingredient to understand short-range attractions between like-charge disclinations. Our study suggests that size polydispersity has a promising potential to engineer defects in various systems including nanoparticles and colloidal crystals.
Park, Myoung-Ok
2017-02-01
[Purpose] The purpose of this study was to determine effects of Gross Motor Function Classification System and Manual Ability Classification System levels on performance-based motor skills of children with spastic cerebral palsy. [Subjects and Methods] Twenty-three children with cerebral palsy were included. The Assessment of Motor and Process Skills was used to evaluate performance-based motor skills in daily life. Gross motor function was assessed using Gross Motor Function Classification Systems, and manual function was measured using the Manual Ability Classification System. [Results] Motor skills in daily activities were significantly different on Gross Motor Function Classification System level and Manual Ability Classification System level. According to the results of multiple regression analysis, children categorized as Gross Motor Function Classification System level III scored lower in terms of performance based motor skills than Gross Motor Function Classification System level I children. Also, when analyzed with respect to Manual Ability Classification System level, level II was lower than level I, and level III was lower than level II in terms of performance based motor skills. [Conclusion] The results of this study indicate that performance-based motor skills differ among children categorized based on Gross Motor Function Classification System and Manual Ability Classification System levels of cerebral palsy.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
...-AM78 Prevailing Rate Systems; North American Industry Classification System Based Federal Wage System... 2007 North American Industry Classification System (NAICS) codes currently used in Federal Wage System... (OPM) issued a final rule (73 FR 45853) to update the 2002 North American Industry Classification...
Understanding the Role of TSC1/2 in Cerebellar Purkinje Neurons
2016-09-01
development of new pharmacotherapy for TSC-patients with autism . 15. SUBJECT TERMS autism , tuberous sclerosis, cerebellum 16. SECURITY CLASSIFICATION...patients with TSC display symptoms of autism spectrum disorder (ASD). Although much research has been conducted, the neural circuitry and molecular...mechanism underlying autism remain unclear. Specific cerebellar defects have been seen in TSC patients, suggesting a crucial role for the cerebellum
Imaging Gallium Nitride High Electron Mobility Transistors to Identify Point Defects
2014-03-01
streamline the sample preparation procedure to maximize the yield of successful samples to be analyzed chemically in an energy dispersive spectrometry...transmission electron microscope (STEM), sample preparation 15. NUMBER OF PAGES 103 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT...Computer Engineering iii THIS PAGE INTENTIONALLY LEFT BLANK iv ABSTRACT The purpose of this thesis is to streamline the sample preparation
Novel Therapy for Bone Regeneration in Large Segmental Defects
2017-12-01
on fracture healing. Clin Orthop Relat Res. 1998;355(Suppl):S230–8. 37. Pape HC, Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4...BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...2, TPO, or saline control. 2. KEYWORDS: Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone
Mechanisms of Mitochondrial Defects in Gulf War Syndrome
2012-08-01
oxidized; POR: porin; TCA: Tricarboxylic acid cycle ( Kreb cycle ). Page 2 Body: YEAR 1 of research (10/13/2009-7/14/2010) (9 months): Human... mitochondria , fatigue, myalgias 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON...abnormalities in genes that are related to mitochondrial function. Hence, investigation of mitochondrial dysfunction in GWS is a priority. Mitochondria
Strain Engineering Defect Concentrations in Reduced Ceria for Improved Electro-Catalytic Performance
2014-06-30
coupling, curvature relaxation, lanthanum strontium ferrite, ceria. oxygen surface exchange 16. SECURITY CLASSIFICATION OF: 17. LlMITATJON OF a. REPORT...Temperature Lanthanum Strontium Ferrite Oxygen Surface Exchange Coefficient Measurements by Curvature Relaxation. 225th Meeting of the Electrochemical...Manuscripts Received Paper TOTAL: Received Paper TOTAL: 06/30/2014 Received Paper 1.00 Qing Yang, Jason Nicholas. Porous Thick Film Lanthanum Strontium
Pullout Performances of Grouted Rockbolt Systems with Bond Defects
NASA Astrophysics Data System (ADS)
Xu, Chang; Li, Zihan; Wang, Shanyong; Wang, Shuren; Fu, Lei; Tang, Chunan
2018-03-01
This paper presents a numerical study on the pullout behaviour of fully grouted rockbolts with bond defects. The cohesive zone model (CZM) is adopted to model the bond-slip behaviour between the rockbolt and grout material. Tensile tests were also conducted to validate the numerical model. The results indicate that the defect length can obviously influence the load and stress distributions along the rockbolt as well as the load-displacement response of the grouted system. Moreover, a plateau in the stress distribution forms due to the bond defect. The linear limit and peak load of the load-displacement response decrease as the defect length increases. A bond defect located closer to the loaded end leads to a longer nonlinear stage in the load-displacement response. However, the peak loads measured from the specimens made with various defect locations are almost approximately the same. The peak load for a specimen with the defects equally spaced along the bolt is higher than that for a specimen with defects concentrated in a certain zone, even with the same total defect length. Therefore, the dispersed pattern of bond defects would be much safer than the concentrated pattern. For the specimen with dispersed defects, the peak load increases with an increase in the defect spacing, even if the total defect length is the same. The peak load for a grouted rockbolt system with defects increases with an increases in the bolt diameter. This work leads to a better understanding of the load transfer mechanism for grouted rockbolt systems with bond defects, and paves the way towards developing a general evaluation method for damaged rockbolt grouted systems.
Hereditary rickets. How genetic alterations explain the biochemical and clinical phenotypes.
Papadopoulou, Anna; Gole, Evaggelia; Nicolaidou, Polyxeni
2013-12-01
The reemergence of vitamin D deficiency in the industrialized countries resurrects the "threat" of nutritional rickets, especially among pediatric populations, a fact that may lead to underdiagnosis of hereditary rickets. Today, hereditary rickets may be subdivided into two main groups according to their biochemical profile: the one associated with defects in vitamin D synthesis and action and the second associated with abnormal phosphorus metabolism. The classification of the patients in a particular group of hereditary rickets is determinative of the treatment to follow. This review, through the recent advances on vitamin D and P metabolism, discusses the molecular and biochemical defects associated to each group of inherited rickets, as well as the clinical phenotypes and the recommended therapeutic approaches.
Rodríguez, Juan; Durán, Cristhian; Reyes, Adriana
2010-01-01
Electronic noses (ENs), are used for many applications, but we must emphasize the importance of their application to foodstuffs like coffee. This paper presents a research study about the analysis of Colombian coffee samples for the detection and classification of defects (i.e., using “Cup Tests”), which was conducted at the Almacafé quality control laboratory in Cúcuta, Colombia. The results obtained show that the application of an electronic nose called “A-NOSE”, may be used in the coffee industry for the cupping tests. The results show that e-nose technology can be a useful tool for quality control to evaluate the excellence of the Colombian coffee produced by National Federation of Coffee Growers. PMID:22315525
Rodríguez, Juan; Durán, Cristhian; Reyes, Adriana
2010-01-01
Electronic noses (ENs), are used for many applications, but we must emphasize the importance of their application to foodstuffs like coffee. This paper presents a research study about the analysis of Colombian coffee samples for the detection and classification of defects (i.e., using "Cup Tests"), which was conducted at the Almacafé quality control laboratory in Cúcuta, Colombia. The results obtained show that the application of an electronic nose called "A-NOSE", may be used in the coffee industry for the cupping tests. The results show that e-nose technology can be a useful tool for quality control to evaluate the excellence of the Colombian coffee produced by National Federation of Coffee Growers.
Montanini, R; Freni, F; Rossi, G L
2012-09-01
This paper reports one of the first experimental results on the application of ultrasound activated lock-in vibrothermography for quantitative assessment of buried flaws in complex cast parts. The use of amplitude modulated ultrasonic heat generation allowed selective response of defective areas within the part, as the defect itself is turned into a local thermal wave emitter. Quantitative evaluation of hidden damages was accomplished by estimating independently both the area and the depth extension of the buried flaws, while x-ray 3D computed tomography was used as reference for sizing accuracy assessment. To retrieve flaw's area, a simple yet effective histogram-based phase image segmentation algorithm with automatic pixels classification has been developed. A clear correlation was found between the thermal (phase) signature measured by the infrared camera on the target surface and the actual mean cross-section area of the flaw. Due to the very fast cycle time (<30 s/part), the method could potentially be applied for 100% quality control of casting components.
Defect engineering in Multinary Semiconductors
NASA Astrophysics Data System (ADS)
Radautsan, S. I.
1993-12-01
The last two decades have shown a rapid increase both in our knowledge of the multinary compounds and their applications in engineering. The remarkable scientific leaders from different countries Prof. N.A.Goryunova, M.Rodot, A. Rabenau, E. Parthe, P. Manca, K. Matsumoto, C. Schwab, R. Tomlinson, J. Woolley, W.T. Kim, T. Irie, A. Zunger, N. Joshi, E. Sato et al. made their valuable contribution to the problems of the classification,crystal chemistry,growing processes and characterizations of multinary compounds [1-3]. Most of them were technologically difficult and as a result it was very hard to obtain the crystals with reproducible parameters. It was therefore obvious the well coordinated efforts in the field of chemistry,physics and electronics to be required. In this paper we review some of the major original results to get the defective compounds suitable for fundamental research and electronic applications. The main attention is paid to such effects as non-stoichiometry, order-disorder phase transitions as well as to non-equilibrium treatment by employing different methods of the defect engineering.
PSO/ACO algorithm-based risk assessment of human neural tube defects in Heshun County, China.
Liao, Yi Lan; Wang, Jin Feng; Wu, Ji Lei; Wang, Jiao Jiao; Zheng, Xiao Ying
2012-10-01
To develop a new technique for assessing the risk of birth defects, which are a major cause of infant mortality and disability in many parts of the world. The region of interest in this study was Heshun County, the county in China with the highest rate of neural tube defects (NTDs). A hybrid particle swarm optimization/ant colony optimization (PSO/ACO) algorithm was used to quantify the probability of NTDs occurring at villages with no births. The hybrid PSO/ACO algorithm is a form of artificial intelligence adapted for hierarchical classification. It is a powerful technique for modeling complex problems involving impacts of causes. The algorithm was easy to apply, with the accuracy of the results being 69.5%±7.02% at the 95% confidence level. The proposed method is simple to apply, has acceptable fault tolerance, and greatly enhances the accuracy of calculations. Copyright © 2012 The Editorial Board of Biomedical and Environmental Sciences. Published by Elsevier B.V. All rights reserved.
A first principles calculation and statistical mechanics modeling of defects in Al-H system
NASA Astrophysics Data System (ADS)
Ji, Min; Wang, Cai-Zhuang; Ho, Kai-Ming
2007-03-01
The behavior of defects and hydrogen in Al was investigated by first principles calculations and statistical mechanics modeling. The formation energy of different defects in Al+H system such as Al vacancy, H in institution and multiple H in Al vacancy were calculated by first principles method. Defect concentration in thermodynamical equilibrium was studied by total free energy calculation including configuration entropy and defect-defect interaction from low concentration limit to hydride limit. In our grand canonical ensemble model, hydrogen chemical potential under different environment plays an important role in determing the defect concentration and properties in Al-H system.
Strudwick, Gillian; Hardiker, Nicholas R
2016-10-01
In the era of evidenced based healthcare, nursing is required to demonstrate that care provided by nurses is associated with optimal patient outcomes, and a high degree of quality and safety. The use of standardized nursing terminologies and classification systems are a way that nursing documentation can be leveraged to generate evidence related to nursing practice. Several widely-reported nursing specific terminologies and classifications systems currently exist including the Clinical Care Classification System, International Classification for Nursing Practice(®), Nursing Intervention Classification, Nursing Outcome Classification, Omaha System, Perioperative Nursing Data Set and NANDA International. However, the influence of these systems on demonstrating the value of nursing and the professions' impact on quality, safety and patient outcomes in published research is relatively unknown. This paper seeks to understand the use of standardized nursing terminology and classification systems in published research, using the International Classification for Nursing Practice(®) as a case study. A systematic review of international published empirical studies on, or using, the International Classification for Nursing Practice(®) were completed using Medline and the Cumulative Index for Nursing and Allied Health Literature. Since 2006, 38 studies have been published on the International Classification for Nursing Practice(®). The main objectives of the published studies have been to validate the appropriateness of the classification system for particular care areas or populations, further develop the classification system, or utilize it to support the generation of new nursing knowledge. To date, most studies have focused on the classification system itself, and a lesser number of studies have used the system to generate information about the outcomes of nursing practice. Based on the published literature that features the International Classification for Nursing Practice, standardized nursing terminology and classification systems appear to be well developed for various populations, settings and to harmonize with other health-related terminology systems. However, the use of the systems to generate new nursing knowledge, and to validate nursing practice is still in its infancy. There is an opportunity now to utilize the well-developed systems in their current state to further what is know about nursing practice, and how best to demonstrate improvements in patient outcomes through nursing care. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, C.-H.; Tan, T. Y.
1995-10-01
Using the theoretically calculated point-defect total-energy values of Baraff and Schlüter in GaAs, an amphoteric-defect model has been proposed by Walukiewicz to explain a large number of experimental results. The suggested amphoteric-defect system consists of two point-defect species capable of transforming into each other: the doubly negatively charged Ga vacancy V {Ga/2-} and the triply positively charged defect complex (ASGa+ V As)3+, with AsGa being the antisite defect of an As atom occupying a Ga site and V As being an As vacancy. When present in sufficiently high concentrations, the amphoteric defect system V {Ga/2-}/(AsGa+ V As)3+ is supposed to be able to pin the GaAs Fermi level at approximately the E v +0.6 eV level position, which requires that the net free energy of the V Ga/(AsGa+ V As) defect system to be minimum at the same Fermi-level position. We have carried out a quantitative study of the net energy of this defect system in accordance with the individual point-defect total-energy results of Baraff and Schlüter, and found that the minimum net defect-system-energy position is located at about the E v +1.2 eV level position instead of the needed E v +0.6 eV position. Therefore, the validity of the amphoteric-defect model is in doubt. We have proposed a simple criterion for determining the Fermi-level pinning position in the deeper part of the GaAs band gap due to two oppositely charged point-defect species, which should be useful in the future.
Dennis L. Mengel; D. Thompson Tew; [Editors
1991-01-01
Eighteen papers representing four categories-Regional Overviews; Classification System Development; Classification System Interpretation; Mapping/GIS Applications in Classification Systems-present the state of the art in forest-land classification and evaluation in the South. In addition, nine poster papers are presented.
42 CFR 412.513 - Patient classification system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Patient classification system. 412.513 Section 412... Long-Term Care Hospitals § 412.513 Patient classification system. (a) Classification methodology. CMS...-DRGs. (1) The classification of a particular discharge is based, as appropriate, on the patient's age...
42 CFR 412.513 - Patient classification system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Patient classification system. 412.513 Section 412... Long-Term Care Hospitals § 412.513 Patient classification system. (a) Classification methodology. CMS...-DRGs. (1) The classification of a particular discharge is based, as appropriate, on the patient's age...
Key Questions in Building Defect Prediction Models in Practice
NASA Astrophysics Data System (ADS)
Ramler, Rudolf; Wolfmaier, Klaus; Stauder, Erwin; Kossak, Felix; Natschläger, Thomas
The information about which modules of a future version of a software system are defect-prone is a valuable planning aid for quality managers and testers. Defect prediction promises to indicate these defect-prone modules. However, constructing effective defect prediction models in an industrial setting involves a number of key questions. In this paper we discuss ten key questions identified in context of establishing defect prediction in a large software development project. Seven consecutive versions of the software system have been used to construct and validate defect prediction models for system test planning. Furthermore, the paper presents initial empirical results from the studied project and, by this means, contributes answers to the identified questions.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera.
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-10-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-01-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods. PMID:28974031
Increased prevalence of some birth defects in Korea, 2009-2010.
Lamichhane, Dirga Kumar; Leem, Jong-Han; Park, Myungsook; Kim, Jung Ae; Kim, Hwan Cheol; Kim, Jin Hee; Hong, Yun-Chul
2016-03-22
Birth defects are a leading cause of neonatal and infant mortality, and several studies have indicated an increase in the prevalence of birth defects; more recent investigations have suggested that the trends of some defects are increasing in rapidly industrialized areas. This study estimates the prevalence rate and types of birth defects in Korea. This study used medical insurance benefit data of 403,250 infants aged less than one year from the National Health Insurance Corporation from seven metropolitan areas in Korea for 2009 and 2010. The prevalence rate of birth defects was 548.3 per 10,000 births (95% CI: 541.1-555.6), 306.8 among boys and 241.5 among girls. Anomalies of the circulatory system (particularly septal defects) were the most common (180.8 per 10,000), followed by defects of the genitourinary tract (130.1 per 10,000) (particularly obstructive genitourinary and undescended testis), musculoskeletal system (105.7 per 10,000), digestive system (24.7 per 10,000), and central nervous system (15.6 per 10,000). Relatively higher rates of some birth defects were found in the metropolitan areas. The high differences of birth prevalences for septal heart defects and undescended testis are probably due in part to progress in clinical management and more frequent prenatal diagnosis. Environmental exposure might play a critical role in the development of some birth defects. In attempting to describe the prevalence and spatio-temporal variations of birth defects in Korea, establishment of a registry system of birth defects and environmental surveillance are needed.
Maternal butalbital use and selected defects in the national birth defects prevention study.
Browne, Marilyn L; Van Zutphen, Alissa R; Botto, Lorenzo D; Louik, Carol; Richardson, Sandra; Druschel, Charlotte M
2014-01-01
Butalbital is a barbiturate contained in combination products with caffeine and an analgesic prescribed for the treatment of migraine and tension-type headaches. Controversy exists as to whether butalbital should continue to be prescribed in the United States because of the potential for abuse, overuse headache, and withdrawal syndromes. Butalbital crosses the placenta but there is limited information about potential teratogenicity. To evaluate associations between butalbital and a wide range of specific birth defects. The National Birth Defects Prevention Study is an ongoing, case-control study of nonsyndromic, major birth defects conducted in 10 states. The detailed case classification and large number of cases in the National Birth Defects Prevention Study allowed us to examine the association between maternal self-reported butalbital use and specific birth defects. We conducted an analysis of 8373 unaffected controls and 21,090 case infants with estimated dates of delivery between 1997 and 2007; included were birth defects with 250 or more cases. An exploratory analysis examined groups with 100 to 249 cases. Seventy-three case mothers and 15 control mothers reported periconceptional butalbital use. Of 30 specific defect groups evaluated, adjusted odds ratios for maternal periconceptional butalbital use were statistically significant for 3 congenital heart defects: tetralogy of Fallot (adjusted odds ratio = 3.04; 95% confidence interval = 1.07-8.62), pulmonary valve stenosis (adjusted odds ratio = 5.73; 95% confidence interval = 2.25-14.62), and secundum-type atrial septal defect (adjusted odds ratio = 3.06; 95% confidence interval = 1.07-8.79). In the exploratory analysis, an elevated odds ratio was detected for 1 congenital heart defect, single ventricle. We observed relationships between maternal periconceptional butalbital use and certain congenital heart defects. These associations have not been reported before, and some may be spurious. Butalbital use was rare and despite the large size of the National Birth Defects Prevention Study, the number of exposed case and control infants was small. However, if confirmed in additional studies, our findings will be useful in weighing the risks and benefits of butalbital for the treatment of migraine and tension-type headaches. © Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
Berlth, Felix; Bollschweiler, Elfriede; Drebber, Uta; Hoelscher, Arnulf H; Moenig, Stefan
2014-01-01
Several pathohistological classification systems exist for the diagnosis of gastric cancer. Many studies have investigated the correlation between the pathohistological characteristics in gastric cancer and patient characteristics, disease specific criteria and overall outcome. It is still controversial as to which classification system imparts the most reliable information, and therefore, the choice of system may vary in clinical routine. In addition to the most common classification systems, such as the Laurén and the World Health Organization (WHO) classifications, other authors have tried to characterize and classify gastric cancer based on the microscopic morphology and in reference to the clinical outcome of the patients. In more than 50 years of systematic classification of the pathohistological characteristics of gastric cancer, there is no sole classification system that is consistently used worldwide in diagnostics and research. However, several national guidelines for the treatment of gastric cancer refer to the Laurén or the WHO classifications regarding therapeutic decision-making, which underlines the importance of a reliable classification system for gastric cancer. The latest results from gastric cancer studies indicate that it might be useful to integrate DNA- and RNA-based features of gastric cancer into the classification systems to establish prognostic relevance. This article reviews the diagnostic relevance and the prognostic value of different pathohistological classification systems in gastric cancer. PMID:24914328
Sequential segmental classification of feline congenital heart disease.
Scansen, Brian A; Schneider, Matthias; Bonagura, John D
2015-12-01
Feline congenital heart disease is less commonly encountered in veterinary medicine than acquired feline heart diseases such as cardiomyopathy. Understanding the wide spectrum of congenital cardiovascular disease demands a familiarity with a variety of lesions, occurring both in isolation and in combination, along with an appreciation of complex nomenclature and variable classification schemes. This review begins with an overview of congenital heart disease in the cat, including proposed etiologies and prevalence, examination approaches, and principles of therapy. Specific congenital defects are presented and organized by a sequential segmental classification with respect to their morphologic lesions. Highlights of diagnosis, treatment options, and prognosis are offered. It is hoped that this review will provide a framework for approaching congenital heart disease in the cat, and more broadly in other animal species based on the sequential segmental approach, which represents an adaptation of the common methodology used in children and adults with congenital heart disease. Copyright © 2015 Elsevier B.V. All rights reserved.
An Analysis of Mission Critical Computer Software in Naval Aviation
1991-03-01
No. Task No. Work Unit Accesion Number 11. TITLE (Include Security Classification) AN ANALYSIS OF MISSION CRITICAL COMPUTER SOFTWARE IN NAVAL AVIATION...software development schedules were sustained without a milestone change being made. Also, software that was released to the fleet had no major...fleet contain any major defects? This research has revealed that only about half of the original software development schedules were sustained without a
A Fundamental Classification of Atomization Processes
2007-10-12
spontaneous dewetting [41, 42], the extra surface tension created by the wall contact would slow any breakdown of perforations into droplets thus...important role in the type and size of the disturbance formed. Small defects can lead to spontaneous dewetting where a perforation is formed [41, 42...Films also may ―spontaneously‖ rupture or dewet due to microscopic surface imperfections or forces on a molecular level [41, 42]. Films are
Novel Therapy for Bone Regeneration in Large Segmental Defects
2016-10-01
Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4):S1–2. 38. Wenda K, Ritter G, Degreif J, Rudigier J. Pathogenesis of pul- monary... fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...saline control. 2. KEYWORDS: Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig
Complete atrioventricular canal.
Calabrò, Raffaele; Limongelli, Giuseppe
2006-04-05
Complete atrioventricular canal (CAVC), also referred to as complete atrioventricular septal defect, is characterised by an ostium primum atrial septal defect, a common atrioventricular valve and a variable deficiency of the ventricular septum inflow. CAVC is an uncommon congenital heart disease, accounting for about 3% of cardiac malformations. Atrioventricular canal occurs in two out of every 10,000 live births. Both sexes are equally affected and a striking association with Down syndrome was found. Depending on the morphology of the superior leaflet of the common atrioventricular valve, 3 types of CAVC have been delineated (type A, B and C, according to Rastelli's classification). CAVC results in a significant interatrial and interventricular systemic-to-pulmonary shunt, thus inducing right ventricular pressure and volume overload and pulmonary hypertension. It becomes symptomatic in infancy due to congestive heart failure and failure to thrive. Diagnosis of CAVC might be suspected from electrocardiographic and chest X-ray findings. Echocardiography confirms it and gives anatomical details. Over time, pulmonary hypertension becomes irreversible, thus precluding the surgical therapy. This is the reason why cardiac catheterisation is not mandatory in infants (less than 6 months) but is indicated in older patients if irreversible pulmonary hypertension is suspected. Medical treatment (digitalis, diuretics, vasodilators) plays a role only as a bridge toward surgery, usually performed between the 3rd and 6th month of life.
Agopian, A J; Lupo, Philip J; Herdt-Losavio, Michele L; Langlois, Peter H; Rocheleau, Carissa M; Mitchell, Laura E
2012-10-01
To describe differences in four high risk periconceptional behaviors (lack of folic acid supplementation, lack of early prenatal care, smoking, and drinking) by maternal occupation. Analyses were conducted among women in the National Birth Defects Prevention Study who delivered liveborn infants without birth defects. Periconceptional occupational data were collected using a computer-assisted telephone interview and occupational coding was performed using the 2000 Standard Occupational Classification System. Logistic regression analyses were conducted to determine whether prevalence of behaviors differed between occupational groups. Subjects included 5153 women employed during early pregnancy from 1997 to 2007. Compared to women in management, business, science, and arts occupations, women in other occupations (e.g., service occupations) were significantly more likely to engage in all four high risk behaviors. Specifically, women in food preparation/serving-related occupations were significantly more likely to engage in all four behaviors compared to women in all other occupational groups (odds ratios: 1.8-3.0), while women in education/training/library occupations were significantly less likely to do so (odds ratios: 0.2-0.5). We identified several occupational groups with an increased prevalence of high-risk maternal behaviors during pregnancy. Our findings could aid in developing interventions targeted towards women in these occupational groups. Copyright © 2012 Elsevier Inc. All rights reserved.
Bearing damage assessment using Jensen-Rényi Divergence based on EEMD
NASA Astrophysics Data System (ADS)
Singh, Jaskaran; Darpe, A. K.; Singh, S. P.
2017-03-01
An Ensemble Empirical Mode Decomposition (EEMD) and Jensen Rényi divergence (JRD) based methodology is proposed for the degradation assessment of rolling element bearings using vibration data. The EEMD decomposes vibration signals into a set of intrinsic mode functions (IMFs). A systematic methodology to select IMFs that are sensitive and closely related to the fault is proposed in the paper. The change in probability distribution of the energies of the sensitive IMFs is measured through JRD which acts as a damage identification parameter. Evaluation of JRD with sensitive IMFs makes it largely unaffected by change/fluctuations in operating conditions. Further, an algorithm based on Chebyshev's inequality is applied to JRD to identify exact points of change in bearing health and remove outliers. The identified change points are investigated for fault classification as possible locations where specific defect initiation could have taken place. For fault classification, two new parameters are proposed: 'α value' and Probable Fault Index, which together classify the fault. To standardize the degradation process, a Confidence Value parameter is proposed to quantify the bearing degradation value in a range of zero to unity. A simulation study is first carried out to demonstrate the robustness of the proposed JRD parameter under variable operating conditions of load and speed. The proposed methodology is then validated on experimental data (seeded defect data and accelerated bearing life test data). The first validation on two different vibration datasets (inner/outer) obtained from seeded defect experiments demonstrate the effectiveness of JRD parameter in detecting a change in health state as the severity of fault changes. The second validation is on two accelerated life tests. The results demonstrate the proposed approach as a potential tool for bearing performance degradation assessment.
Classification System for Individualized Treatment of Adult Buried Penis Syndrome.
Tausch, Timothy J; Tachibana, Isamu; Siegel, Jordan A; Hoxworth, Ronald; Scott, Jeremy M; Morey, Allen F
2016-09-01
The authors present their experience with reconstructive strategies for men with various manifestations of adult buried penis syndrome, and propose a comprehensive anatomical classification system and treatment algorithm based on pathologic changes in the penile skin and involvement of neighboring abdominal and/or scrotal components. The authors reviewed all patients who underwent reconstruction of adult buried penis syndrome at their referral center between 2007 and 2015. Patients were stratified by location and severity of involved anatomical components. Procedures performed, demographics, comorbidities, and clinical outcomes were reviewed. Fifty-six patients underwent reconstruction of buried penis at the authors' center from 2007 to 2015. All procedures began with a ventral penile release. If the uncovered penile skin was determined to be viable, a phalloplasty was performed by anchoring penoscrotal skin to the proximal shaft, and the ventral shaft skin defect was closed with scrotal flaps. In more complex patients with circumferential nonviable penile skin, the penile skin was completely excised and replaced with a split-thickness skin graft. Complex patients with severe abdominal lipodystrophy required adjacent tissue transfer. For cases of genital lymphedema, the procedure involved complete excision of the lymphedematous tissue, and primary closure with or without a split-thickness skin graft, also often involving the scrotum. The authors' overall success rate was 88 percent (49 of 56), defined as resolution of symptoms without the need for additional procedures. Successful correction of adult buried penis often necessitates an interdisciplinary, multimodal approach. Therapeutic, IV.
Topological crystalline materials: General formulation, module structure, and wallpaper groups
NASA Astrophysics Data System (ADS)
Shiozaki, Ken; Sato, Masatoshi; Gomi, Kiyonori
2017-06-01
We formulate topological crystalline materials on the basis of the twisted equivariant K theory. Basic ideas of the twisted equivariant K theory are explained with application to topological phases protected by crystalline symmetries in mind, and systematic methods of topological classification for crystalline materials are presented. Our formulation is applicable to bulk gapful topological crystalline insulators/superconductors and their gapless boundary and defect states, as well as bulk gapless topological materials such as Weyl and Dirac semimetals, and nodal superconductors. As an application of our formulation, we present a complete classification of topological crystalline surface states, in the absence of time-reversal invariance. The classification works for gapless surface states of three-dimensional insulators, as well as full gapped two-dimensional insulators. Such surface states and two-dimensional insulators are classified in a unified way by 17 wallpaper groups, together with the presence or the absence of (sublattice) chiral symmetry. We identify the topological numbers and their representations under the wallpaper group operation. We also exemplify the usefulness of our formulation in the classification of bulk gapless phases. We present a class of Weyl semimetals and Weyl superconductors that are topologically protected by inversion symmetry.
Waring, R; Knight, R
2013-01-01
Children with speech sound disorders (SSD) form a heterogeneous group who differ in terms of the severity of their condition, underlying cause, speech errors, involvement of other aspects of the linguistic system and treatment response. To date there is no universal and agreed-upon classification system. Instead, a number of theoretically differing classification systems have been proposed based on either an aetiological (medical) approach, a descriptive-linguistic approach or a processing approach. To describe and review the supporting evidence, and to provide a critical evaluation of the current childhood SSD classification systems. Descriptions of the major specific approaches to classification are reviewed and research papers supporting the reliability and validity of the systems are evaluated. Three specific paediatric SSD classification systems; the aetiologic-based Speech Disorders Classification System, the descriptive-linguistic Differential Diagnosis system, and the processing-based Psycholinguistic Framework are identified as potentially useful in classifying children with SSD into homogeneous subgroups. The Differential Diagnosis system has a growing body of empirical support from clinical population studies, across language error pattern studies and treatment efficacy studies. The Speech Disorders Classification System is currently a research tool with eight proposed subgroups. The Psycholinguistic Framework is a potential bridge to linking cause and surface level speech errors. There is a need for a universally agreed-upon classification system that is useful to clinicians and researchers. The resulting classification system needs to be robust, reliable and valid. A universal classification system would allow for improved tailoring of treatments to subgroups of SSD which may, in turn, lead to improved treatment efficacy. © 2012 Royal College of Speech and Language Therapists.
Late Causes of Death After Pediatric Cardiac Surgery: A 60-Year Population-Based Study.
Raissadati, Alireza; Nieminen, Heta; Haukka, Jari; Sairanen, Heikki; Jokinen, Eero
2016-08-02
Comprehensive information regarding causes of late post-operative death following pediatric congenital cardiac surgery is lacking. The study sought to analyze late causes of death after congenital cardiac surgery by era and defect severity. We obtained data from a nationwide pediatric cardiac surgery database and Finnish population registry regarding patients who underwent cardiac surgery at <15 years of age at 1 of 5 universities or 1 district hospital in Finland from 1953 to 2009. Noncyanotic and cyanotic defects were classified as simple and severe, respectively. Causes of death were determined using International Classification of Diseases diagnostic codes. Deaths among the study population were compared to a matched control population. Overall, 10,964 patients underwent 14,079 operations, with 98% follow-up. Early mortality (<30 days) was 5.6% (n = 613). Late mortality was 10.4% (n = 1,129). Congenital heart defect (CHD)-related death rates correlated with defect severity. Heart failure was the most common mode of CHD-related death, but decreased after surgeries performed between 1990 and 2009. Sudden death after surgery for atrial septal defect, ventricular septal defect, tetralogy of Fallot, and transposition of the great arteries decreased to zero following operations from 1990 to 2009. Deaths from neoplasms, respiratory, neurological, and infectious disease were significantly more common among study patients than controls. Pneumonia caused the majority of non-CHD-related deaths among the study population. CHD-related deaths have decreased markedly but remain a challenge after surgery for severe cardiac defects. Premature deaths are generally more common among patients than the control population, warranting long-term follow-up after congenital cardiac surgery. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
[Birth defects in Rio de Janeiro, Brazil: an evaluation through birth certificates (2000-2004)].
Guerra, Fernando Antônio Ramos; Llerena, Juan Clinton; Gama, Silvana Granado Nogueira da; Cunha, Cynthia Braga da; Theme Filha, Mariza Miranda
2008-01-01
To evaluate the occurrence of birth defects in the city of Rio de Janeiro, Brazil, using the Live Birth Information System (SINASC), we performed a cross-sectional study on all live newborns with birth defects from January 1, 2000, to December 31, 2004. The variables referred to birth defects (presence and system affected), type of health service, mothers, gestations, live births, and deliveries. Prevalence of birth defects was 83/10,000 live births. The most frequent birth defects involved the musculoskeletal system, central nervous system, cleft lip and palate, and chromosomal anomalies. The majority of cases were born in public (municipal) and private maternity hospitals, with the highest prevalence in the Fernandes Figueira Insitute, Oswaldo Cruz Foundation. Older women and those with less schooling had more live born infants with birth defects. The proportion of reports with missing information was high, reaching 21% in some institutions. Wider dissemination of SINASC data on birth defects should be encouraged. Reliability studies are recommended for better use of these reports.
Modell, Vicki; Orange, Jordan S; Quinn, Jessica; Modell, Fred
2018-05-09
Primary immunodeficiencies (PI) are genetic defects of the immune system that result in chronic, serious, and often life-threatening infections, if not diagnosed and treated. Many patients with PI are undiagnosed, underdiagnosed, or misdiagnosed. In fact, recent studies have shown that PI may be more common than previously estimated and that as many as 1% of the population may be affected with a PI when all types and varieties are considered. In order to raise awareness of PI with the overall goal of reducing associated morbidity and mortality, the Jeffrey Modell Foundation (JMF) established a network of specialized centers that could better identify, diagnose, treat, and follow patients with PI disorders. Over the past decade, the Jeffrey Modell Centers Network (JMCN) has provided the infrastructure to accept referrals, provide diagnosis, and offer treatments. Currently, the network consists of 792 Expert Physicians at 358 institutions, in 277 cities, and 86 countries spanning 6 continents. JMF developed an annual survey for physician experts within the JMCN, using the categories and gene defects identified by the International Union of Immunological Societies Expert Committee for the Classification of PI, to report on the number of patients identified with PI; treatment modalities, including immunoglobulins, transplantation, and gene therapy; and data on gender and age. Center Directors also provided physician-reported outcomes and differentials pre- and post-diagnosis. The current physician-reported data reflect an increase in diagnosed patients, as well as those receiving treatment. Suspected patients are being identified and referred so that they can receive early and appropriate diagnosis and treatment. The significant increase in patients identified with a PI is due, in part, to expanding education and awareness initiatives, newborn screening, and the expansion of molecular diagnosis and sequencing. To our knowledge, this is the most extensive single physician report on patients with PI around the world.
5 CFR 9701.231 - Conversion of positions and employees to the DHS classification system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the DHS classification system. 9701.231 Section 9701.231 Administrative Personnel DEPARTMENT OF... MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Transitional Provisions § 9701.231 Conversion of positions and employees to the DHS classification system. (a) This...
Randall, Brad B.; Wadee, Sabbir A.; Sens, Mary Ann; Kinney, Hannah C.; Folkerth, Rebecca D.; Odendaal, Hein J.; Dempers, Johan J.
2012-01-01
Although the rate of the sudden infant death syndrome (SIDS) has decreased over the last two decades, medical examiners and coroners are increasingly unwilling to use the SIDS diagnosis, particularly when there is an unsafe sleeping environment that might pose a risk for asphyxia. In order to reliably classify the infant deaths studied in a research setting in the mixed ancestory population in Cape Town, South Africa, we tested a classification system devised by us that incorporates the uncertainty of asphyxial risks at an infant death scene. We classified sudden infant deaths as: A) SIDS (where only a trivial potential for an overt asphyxial event existed); B) Unclassified—Possibly Asphyxial-Related (when any potential for an asphyxial death existed); C) Unclassified—Non-Asphyxial-Related (e.g., hyperthermia); D) Unclassified—No autopsy and/or death scene investigation; and E) Known Cause of Death. Ten infant deaths were classified according to the proposed schema as: SIDS, n = 2; Unclassified—Possibly Asphyxial-Related, n = 4; and Known Cause, n = 4. A conventional schema categorized the deaths as 6 cases, SIDS, and 4 cases, Known Cause, indicating that 4/6 (67%) of deaths previously classified as SIDS are considered related importantly to asphyxia and warrant their own subgroup. This new classification schema applies a simpler, more qualitative approach to asphyxial risk in infant deaths. It also allows us to test hypotheses about the role of asphyxia in sudden infant deaths, such as in brainstem defects in a range of asphyxial challenges. PMID:19484508
Defects formation and wave emitting from defects in excitable media
NASA Astrophysics Data System (ADS)
Ma, Jun; Xu, Ying; Tang, Jun; Wang, Chunni
2016-05-01
Abnormal electrical activities in neuronal system could be associated with some neuronal diseases. Indeed, external forcing can cause breakdown even collapse in nervous system under appropriate condition. The excitable media sometimes could be described by neuronal network with different topologies. The collective behaviors of neurons can show complex spatiotemporal dynamical properties and spatial distribution for electrical activities due to self-organization even from the regulating from central nervous system. Defects in the nervous system can emit continuous waves or pulses, and pacemaker-like source is generated to perturb the normal signal propagation in nervous system. How these defects are developed? In this paper, a network of neurons is designed in two-dimensional square array with nearest-neighbor connection type; the formation mechanism of defects is investigated by detecting the wave propagation induced by external forcing. It is found that defects could be induced under external periodical forcing under the boundary, and then the wave emitted from the defects can keep balance with the waves excited from external forcing.
Pattern centric design based sensitive patterns and process monitor in manufacturing
NASA Astrophysics Data System (ADS)
Hsiang, Chingyun; Cheng, Guojie; Wu, Kechih
2017-03-01
When design rule is mitigating to smaller dimension, process variation requirement is tighter than ever and challenges the limits of device yield. Masks, lithography, etching and other processes have to meet very tight specifications in order to keep defect and CD within the margins of the process window. Conventionally, Inspection and metrology equipments are utilized to monitor and control wafer quality in-line. In high throughput optical inspection, nuisance and review-classification become a tedious labor intensive job in manufacturing. Certain high-resolution SEM images are taken to validate defects after optical inspection. These high resolution SEM images catch not only optical inspection highlighted point, also its surrounding patterns. However, this pattern information is not well utilized in conventional quality control method. Using this complementary design based pattern monitor not only monitors and analyzes the variation of patterns sensitivity but also reduce nuisance and highlight defective patterns or killer defects. After grouping in either single or multiple layers, systematic defects can be identified quickly in this flow. In this paper, we applied design based pattern monitor in different layers to monitor process variation impacts on all kinds of patterns. First, the contour of high resolutions SEM image is extracted and aligned to design with offset adjustment and fine alignment [1]. Second, specified pattern rules can be applied on design clip area, the same size as SEM image, and form POI (pattern of interest) areas. Third, the discrepancy of contour and design measurement at different pattern types in measurement blocks. Fourth, defective patterns are reported by discrepancy detection criteria and pattern grouping [4]. Meanwhile, reported pattern defects are ranked by number and severity by discrepancy. In this step, process sensitive high repeatable systematic defects can be identified quickly Through this design based process pattern monitor method, most of optical inspection nuisances can be filtered out at contour to design discrepancy measurement. Daily analysis results are stored at database as reference to compare with incoming data. Defective pattern library contains existing and known systematic defect patterns which help to catch and identify new pattern defects or process impacts. On the other hand, this defect pattern library provides extra valuable information for mask, pattern and defects verification, inspection care area generation, further OPC fix and process enhancement and investigation.
Chiral photonic crystals with an anisotropic defect layer.
Gevorgyan, A H; Harutyunyan, M Z
2007-09-01
In the present paper we consider some properties of defect modes in chiral photonic crystals with an anisotropic defect layer. We solved the problem by Ambartsumian's layer addition method. We investigated the influence of the defect layer thickness variation and its location in the chiral photonic crystal (CPC) and also its optical axes orientation, as well as of CPC thickness variation on defect mode properties. Variations of the optical thickness of the defect layer have its impact on the defect mode linewidth and the light accumulation in the defect. We obtain that CPCs lose their base property at certain defect layer thicknesses; namely, they lose their diffraction reflection dependence on light polarization. We also show that the circular polarization handedness changes from right-handed to left-handed if the defect layer location is changed, and therefore, such systems can be used to create sources of elliptically polarized light with tunable ellipticity. Some nonreciprocity properties of such systems are investigated, too. In particular, it is also shown that such a system can work as a practically ideal wide band optical diode for circularly polarized incident light provided the defect layer thickness is properly chosen, and it can work as a narrow band diode at small defect layer thicknesses.
Quality Assurance By Laser Scanning And Imaging Techniques
NASA Astrophysics Data System (ADS)
SchmalfuB, Harald J.; Schinner, Karl Ludwig
1989-03-01
Laser scanning systems are well established in the world of fast industrial in-process quality inspection systems. The materials inspected by laser scanning systems are e.g. "endless" sheets of steel, paper, textile, film or foils. The web width varies from 50 mm up to 5000 mm or more. The web speed depends strongly on the production process and can reach several hundred meters per minute. The continuous data flow in one of different channels of the optical receiving system exceeds ten Megapixels/sec. Therefore it is clear that the electronic evaluation system has to process these data streams in real time and no image storage is possible. But sometimes (e.g. first installation of the system, change of the defect classification) it would be very helpful to have the possibility for a visual look on the original, i.e. not processed sensor data. At first we show the principle set up of a standard laser scanning system. Then we will introduce a large image memory especially designed for the needs of high-speed inspection sensors. This image memory co-operates with the standard on-line evaluation electronics and provides therefore an easy comparison between processed and non-processed data. We will discuss the basic system structure and we will show the first industrial results.
Waltho, Daniel; Hatchell, Alexandra; Thoma, Achilleas
2017-03-01
Gynecomastia is a common deformity of the male breast, where certain cases warrant surgical management. There are several surgical options, which vary depending on the breast characteristics. To guide surgical management, several classification systems for gynecomastia have been proposed. A systematic review was performed to (1) identify all classification systems for the surgical management of gynecomastia, and (2) determine the adequacy of these classification systems to appropriately categorize the condition for surgical decision-making. The search yielded 1012 articles, and 11 articles were included in the review. Eleven classification systems in total were ascertained, and a total of 10 unique features were identified: (1) breast size, (2) skin redundancy, (3) breast ptosis, (4) tissue predominance, (5) upper abdominal laxity, (6) breast tuberosity, (7) nipple malposition, (8) chest shape, (9) absence of sternal notch, and (10) breast skin elasticity. On average, classification systems included two or three of these features. Breast size and ptosis were the most commonly included features. Based on their review of the current classification systems, the authors believe the ideal classification system should be universal and cater to all causes of gynecomastia; be surgically useful and easy to use; and should include a comprehensive set of clinically appropriate patient-related features, such as breast size, breast ptosis, tissue predominance, and skin redundancy. None of the current classification systems appears to fulfill these criteria.
The National Birth Defects Prevention Study: a review of the methods
Reefhuis, Jennita; Gilboa, Suzanne M.; Anderka, Marlene; Browne, Marilyn L.; Feldkamp, Marcia L.; Hobbs, Charlotte A.; Jenkins, Mary M.; Langlois, Peter H.; Newsome, Kimberly B.; Olshan, Andrew F.; Romitti, Paul A.; Shapira, Stuart K.; Shaw, Gary M.; Tinker, Sarah C.; Honein, Margaret A.
2015-01-01
Background The National Birth Defects Prevention Study (NBDPS) is a large population-based multi-center case-control study of major birth defects in the United States. Methods Data collection took place from 1998 through 2013 on pregnancies ending between October 1997 and December 2011. Cases could be live born, stillborn or induced terminations, and were identified from birth defects surveillance programs in Arkansas, California, Georgia, Iowa, Massachusetts, New Jersey, New York, North Carolina, Texas and Utah. Controls were live born infants without major birth defects identified from the same geographical regions and time periods as cases via either vital records or birth hospitals. Computer-assisted telephone interviews were completed with women between 6 weeks and 24 months after the estimated date of delivery. After completion of interviews, families received buccal cell collection kits for the mother, father and infant (if living). Results There were 47,832 eligible cases and 18,272 eligible controls. Among these, 32,187 (67%) and 11,814 (65%) respectively, provided interview information about their pregnancies. Buccal cell collection kits with a cytobrush for at least one family member were returned by 19,065 case and 6,211 control families (65% and 59% of those who were sent a kit). More than 500 projects have been proposed by the collaborators and over 200 manuscripts published using data from the NBDPS through December 2014. Conclusion The NBDPS has made substantial contributions to the field of birth defects epidemiology through its rigorous design, including case classification, detailed questionnaire and specimen collection, large study population, and collaborative activities across Centers. PMID:26033852
The National Birth Defects Prevention Study: A review of the methods.
Reefhuis, Jennita; Gilboa, Suzanne M; Anderka, Marlene; Browne, Marilyn L; Feldkamp, Marcia L; Hobbs, Charlotte A; Jenkins, Mary M; Langlois, Peter H; Newsome, Kimberly B; Olshan, Andrew F; Romitti, Paul A; Shapira, Stuart K; Shaw, Gary M; Tinker, Sarah C; Honein, Margaret A
2015-08-01
The National Birth Defects Prevention Study (NBDPS) is a large population-based multicenter case-control study of major birth defects in the United States. Data collection took place from 1998 through 2013 on pregnancies ending between October 1997 and December 2011. Cases could be live born, stillborn, or induced terminations, and were identified from birth defects surveillance programs in Arkansas, California, Georgia, Iowa, Massachusetts, New Jersey, New York, North Carolina, Texas, and Utah. Controls were live born infants without major birth defects identified from the same geographical regions and time periods as cases by means of either vital records or birth hospitals. Computer-assisted telephone interviews were completed with women between 6 weeks and 24 months after the estimated date of delivery. After completion of interviews, families received buccal cell collection kits for the mother, father, and infant (if living). There were 47,832 eligible cases and 18,272 eligible controls. Among these, 32,187 (67%) and 11,814 (65%), respectively, provided interview information about their pregnancies. Buccal cell collection kits with a cytobrush for at least one family member were returned by 19,065 case and 6,211 control families (65% and 59% of those who were sent a kit). More than 500 projects have been proposed by the collaborators and over 200 manuscripts published using data from the NBDPS through December 2014. The NBDPS has made substantial contributions to the field of birth defects epidemiology through its rigorous design, including case classification, detailed questionnaire and specimen collection, large study population, and collaborative activities across Centers. © 2015 Wiley Periodicals, Inc.
Risk of central nervous system defects in offspring of women with and without mental illness.
Ayoub, Aimina; Fraser, William D; Low, Nancy; Arbour, Laura; Healy-Profitós, Jessica; Auger, Nathalie
2018-02-22
We sought to determine the relationship between maternal mental illness and the risk of having an infant with a central nervous system defect. We analyzed a cohort of 654,882 women aged less than 20 years between 1989 and 2013 who later delivered a live born infant in any hospital in Quebec, Canada. The primary exposure was mental illness during pregnancy or hospitalization for mental illness before pregnancy. The outcomes were neural and non-neural tube defects of the central nervous system in any offspring. We computed risk ratios (RR) and 95% confidence intervals (CI) for the association between mental disorders and risk of central nervous system defects in log-binomial regression models adjusted for age at delivery, total parity, comorbidity, socioeconomic deprivation, place of residence, and time period. Maternal mental illness was associated with an increased risk of nervous system defects in offspring (RR 1.76, 95% CI 1.64-1.89). Hospitalization for any mental disorder was more strongly associated with non-neural tube (RR 1.84, 95% CI 1.71-1.99) than neural tube defects (RR 1.31, 95% CI 1.08-1.59). Women at greater risk of nervous system defects in offspring tended to be diagnosed with multiple mental disorders, have more than one hospitalization for mental disease, or be 17 or older at first hospitalization. A history of mental illness is associated with central nervous system defects in offspring. Women hospitalized for mental illness may merit counseling at first symptoms to prevent central nervous system defects at pregnancy.
van der Heijden, Martijn; Dikkers, Frederik G; Halmos, Gyorgy B
2015-12-01
Laryngomalacia is the most common cause of dyspnea and stridor in newborn infants. Laryngomalacia is a dynamic change of the upper airway based on abnormally pliable supraglottic structures, which causes upper airway obstruction. In the past, different classification systems have been introduced. Until now no classification system is widely accepted and applied. Our goal is to provide a simple and complete classification system based on systematic literature search and our experiences. Retrospective cohort study with literature review. All patients with laryngomalacia under the age of 5 at time of diagnosis were included. Photo and video documentation was used to confirm diagnosis and characteristics of dynamic airway change. Outcome was compared with available classification systems in literature. Eighty-five patients were included. In contrast to other classification systems, only three typical different dynamic changes have been identified in our series. Two existing classification systems covered 100% of our findings, but there was an unnecessary overlap between different types in most of the systems. Based on our finding, we propose a new a classification system for laryngomalacia, which is purely based on dynamic airway changes. The groningen laryngomalacia classification is a new, simplified classification system with three types, based on purely dynamic laryngeal changes, tested in a tertiary referral center: Type 1: inward collapse of arytenoids cartilages, Type 2: medial displacement of aryepiglottic folds, and Type 3: posterocaudal displacement of epiglottis against the posterior pharyngeal wall. © 2015 Wiley Periodicals, Inc.
Ryu, Sunmin; Brus, Louis E.; Steigerwald, Michael L.; Liu, Haitao
2012-09-25
Systems and methods are disclosed herein for forming defects on graphitic materials. The methods for forming defects include applying a radiation reactive material on a graphitic material, irradiating the applied radiation reactive material to produce a reactive species, and permitting the reactive species to react with the graphitic material to form defects. Additionally, disclosed are methods for removing defects on graphitic materials.
Novel Therapy for Bone Regeneration in Large Segmental Defects
2017-12-01
HC, Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4):S1–2. 38. Wenda K, Ritter G, Degreif J, Rudigier J. Pathogenesis of pul...morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17... fracture healing, bone regeneration, minipig, pig 3. OVERALL PROJECT SUMMARY: Project start date 30/09/2013 Project end date 29/09/2017 (with 1 year NCE
First-Principles Study of Defects in GaN, AlN and Their Alloys
2010-08-31
Compounds 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Same as Report (SAR) 18. NUMBER OF PAGES 65 19a. NAME OF RESPONSIBLE... compounds because we would like to systematically study the trend of the elastic constants and sound velocities with respect to the ionicity of material...Singapore International Convention & Exhibition Centre, Singapore [C6] “First Principles Study of Gallium -Frenkel Pairs in Gallium Nitride” at the
Comment on ’Single Pentacene Molecules Detected by Fluorescence Excitation in a P-Terphenyl Crystal’
1990-12-10
8217 NO 11 TITLE (include Security Classification) Comment on "Single Pentacene Molecules Detected by Fluorescence Excitation in a p-Terphenyl Crystal" 12...8217 {Continue on reverse it necessary and identify by block numboer) Using h--,Ihly efficient Fluorescence excitation spectroscov of individual pentacene ...molecular impurities in p-terphenvl crystals, we have observed that some pentacene defects exhibit spcntaneous spectral jumps in their resonance frequency at
Nevin, N C; McDonald, J R; Walby, A L
1978-12-01
The efficiency of two systems for recording congenital malformations has been compared; one system, the Registrar General's Congenital Malformation Notification, is based on registering all malformed infants, and the other, the Child Health System, records all births. In Northern Ireland for three years [1974--1976], using multiple sources of ascertainment, a total of 686 infants with neural tube defects was identified among 79 783 live and stillbirths. The incidence for all neural tube defects in 8 60 per 1 000 births. The Registrar General's Congenital Malformation Notification System identified 83.6% whereas the Child Health System identified only 63.3% of all neural tube defects. Both systems together identified 86.2% of all neural tube defects. The two systems are suitable for monitoring of malformations and the addition of information from the Genetic Counselling Clinics would enhance the data for epidemiological studies.
Designing and Implementation of River Classification Assistant Management System
NASA Astrophysics Data System (ADS)
Zhao, Yinjun; Jiang, Wenyuan; Yang, Rujun; Yang, Nan; Liu, Haiyan
2018-03-01
In an earlier publication, we proposed a new Decision Classifier (DCF) for Chinese river classification based on their structures. To expand, enhance and promote the application of the DCF, we build a computer system to support river classification named River Classification Assistant Management System. Based on ArcEngine and ArcServer platform, this system implements many functions such as data management, extraction of river network, river classification, and results publication under combining Client / Server with Browser / Server framework.
Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
Rowe, Fiona J.; Rowlands, Alison
2014-01-01
Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983
A comparison of techniques for myelomeningocele defect closure in the neonatal period.
Kobraei, Edward M; Ricci, Joseph A; Vasconez, Henry C; Rinker, Brian D
2014-09-01
Numerous techniques have been described for repair of myelomeningoceles, but outcome data is scarce. A retrospective review was performed in 32 consecutive patients who underwent neonatal myelomeningocele repair and extra-dural closure to determine the influence of repair type on outcome. All procedures for myelomeningocele closure were classified into one of three groups, which included primary closure, myocutaneous flaps, and fasciocutaneous flaps. Defect size ranged from 1 to 48 cm(2). Primary skin closure was performed in 3 patients, fasciocutaneous flaps in 13 patients, and myocutaneous flaps in 16 patients. The overall complication rate was 18%. No difference in the complication rates among the primary closure, myocutaneous, and fasciocutaneous flap groups was observed in our analysis. While not statistically significant, our data documents an association of fasciocutaneous flaps with postoperative complications that were not evident with primary skin closure or myocutaneous flaps (odds ratio 3.8; p = 0.15). The occurrence of one or more complications was associated with a longer hospital stay. Myocutaneous flaps provide a secure repair and should be considered for smaller myelomeningocele defects in addition to the larger defects where they are more traditionally used. We propose a tissue-based classification of closure techniques strictly for multi-institution outcome comparison that may ultimately inform clinical decision-making.
42 CFR 412.10 - Changes in the DRG classification system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Changes in the DRG classification system. 412.10... § 412.10 Changes in the DRG classification system. (a) General rule. CMS issues changes in the DRG classification system in a Federal Register notice at least annually. Except as specified in paragraphs (c) and...
42 CFR 412.10 - Changes in the DRG classification system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Changes in the DRG classification system. 412.10... § 412.10 Changes in the DRG classification system. (a) General rule. CMS issues changes in the DRG classification system in a Federal Register notice at least annually. Except as specified in paragraphs (c) and...
ERIC Educational Resources Information Center
Hidecker, Mary Jo Cooley; Ho, Nhan Thi; Dodge, Nancy; Hurvitz, Edward A.; Slaughter, Jaime; Workinger, Marilyn Seif; Kent, Ray D.; Rosenbaum, Peter; Lenski, Madeleine; Messaros, Bridget M.; Vanderbeek, Suzette B.; Deroos, Steven; Paneth, Nigel
2012-01-01
Aim: To investigate the relationships among the Gross Motor Function Classification System (GMFCS), Manual Ability Classification System (MACS), and Communication Function Classification System (CFCS) in children with cerebral palsy (CP). Method: Using questionnaires describing each scale, mothers reported GMFCS, MACS, and CFCS levels in 222…
NASA Astrophysics Data System (ADS)
Warren, Sean N.; Kallu, Raj R.; Barnard, Chase K.
2016-11-01
Underground gold mines in Nevada are exploiting increasingly deeper ore bodies comprised of weak to very weak rock masses. The Rock Mass Rating (RMR) classification system is widely used at underground gold mines in Nevada and is applicable in fair to good-quality rock masses, but is difficult to apply and loses reliability in very weak rock mass to soil-like material. Because very weak rock masses are transition materials that border engineering rock mass and soil classification systems, soil classification may sometimes be easier and more appropriate to provide insight into material behavior and properties. The Unified Soil Classification System (USCS) is the most likely choice for the classification of very weak rock mass to soil-like material because of its accepted use in tunnel engineering projects and its ability to predict soil-like material behavior underground. A correlation between the RMR and USCS systems was developed by comparing underground geotechnical RMR mapping to laboratory testing of bulk samples from the same locations, thereby assigning a numeric RMR value to the USCS classification that can be used in spreadsheet calculations and geostatistical analyses. The geotechnical classification system presented in this paper including a USCS-RMR correlation, RMR rating equations, and the Geo-Pick Strike Index is collectively introduced as the Weak Rock Mass Rating System (W-RMR). It is the authors' hope that this system will aid in the classification of weak rock masses and more usable design tools based on the RMR system. More broadly, the RMR-USCS correlation and the W-RMR system help define the transition between engineering soil and rock mass classification systems and may provide insight for geotechnical design in very weak rock masses.
Medehouenou, Thierry Comlan Marc; Ayotte, Pierre; St-Jean, Audray; Meziou, Salma; Roy, Cynthia; Muckle, Gina; Lucas, Michel
2015-07-01
Little is known about the suitability of three commonly used body mass index (BMI) classification system for Indigenous children. This study aims to estimate overweight and obesity prevalence among school-aged Nunavik Inuit children according to International Obesity Task Force (IOTF), Centers for Disease Control and Prevention (CDC), and World Health Organization (WHO) BMI classification systems, to measure agreement between those classification systems, and to investigate whether BMI status as defined by these classification systems is associated with levels of metabolic and inflammatory biomarkers. Data were collected on 290 school-aged children (aged 8-14 years; 50.7% girls) from the Nunavik Child Development Study with data collected in 2005-2010. Anthropometric parameters were measured and blood sampled. Participants were classified as normal weight, overweight, and obese according to BMI classification systems. Weighted kappa (κw) statistics assessed agreement between different BMI classification systems, and multivariate analysis of variance ascertained their relationship with metabolic and inflammatory biomarkers. The combined prevalence rate of overweight/obesity was 26.9% (with 6.6% obesity) with IOTF, 24.1% (11.0%) with CDC, and 40.4% (12.8%) with WHO classification systems. Agreement was the highest between IOTF and CDC (κw = .87) classifications, and substantial for IOTF and WHO (κw = .69) and for CDC and WHO (κw = .73). Insulin and high-sensitivity C-reactive protein plasma levels were significantly higher from normal weight to obesity, regardless of classification system. Among obese subjects, higher insulin level was observed with IOTF. Compared with other systems, IOTF classification appears to be more specific to identify overweight and obesity in Inuit children. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Stroke subtyping for genetic association studies? A comparison of the CCS and TOAST classifications.
Lanfranconi, Silvia; Markus, Hugh S
2013-12-01
A reliable and reproducible classification system of stroke subtype is essential for epidemiological and genetic studies. The Causative Classification of Stroke system is an evidence-based computerized algorithm with excellent inter-rater reliability. It has been suggested that, compared to the Trial of ORG 10172 in Acute Stroke Treatment classification, it increases the proportion of cases with defined subtype that may increase power in genetic association studies. We compared Trial of ORG 10172 in Acute Stroke Treatment and Causative Classification of Stroke system classifications in a large cohort of well-phenotyped stroke patients. Six hundred ninety consecutively recruited patients with first-ever ischemic stroke were classified, using review of clinical data and original imaging, according to the Trial of ORG 10172 in Acute Stroke Treatment and Causative Classification of Stroke system classifications. There was excellent agreement subtype assigned by between Trial of ORG 10172 in Acute Stroke Treatment and Causative Classification of Stroke system (kappa = 0·85). The agreement was excellent for the major individual subtypes: large artery atherosclerosis kappa = 0·888, small-artery occlusion kappa = 0·869, cardiac embolism kappa = 0·89, and undetermined category kappa = 0·884. There was only moderate agreement (kappa = 0·41) for the subjects with at least two competing underlying mechanism. Thirty-five (5·8%) patients classified as undetermined by Trial of ORG 10172 in Acute Stroke Treatment were assigned to a definite subtype by Causative Classification of Stroke system. Thirty-two subjects assigned to a definite subtype by Trial of ORG 10172 in Acute Stroke Treatment were classified as undetermined by Causative Classification of Stroke system. There is excellent agreement between classification using Trial of ORG 10172 in Acute Stroke Treatment and Causative Classification of Stroke systems but no evidence that Causative Classification of Stroke system reduced the proportion of patients classified to undetermined subtypes. The excellent inter-rater reproducibility and web-based semiautomated nature make Causative Classification of Stroke system suitable for multicenter studies, but the benefit of reclassifying cases already classified using the Trial of ORG 10172 in Acute Stroke Treatment system on existing databases is likely to be small. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.
Liya Thomas; R. Edward Thomas
2011-01-01
We have developed an automated defect detection system and a state-of-the-art Graphic User Interface (GUI) for hardwood logs. The algorithm identifies defects at least 0.5 inch high and at least 3 inches in diameter on barked hardwood log and stem surfaces. To summarize defect features and to build a knowledge base, hundreds of defects were measured, photographed, and...
2014-01-01
Background The inter-patient classification schema and the Association for the Advancement of Medical Instrumentation (AAMI) standards are important to the construction and evaluation of automated heartbeat classification systems. The majority of previously proposed methods that take the above two aspects into consideration use the same features and classification method to classify different classes of heartbeats. The performance of the classification system is often unsatisfactory with respect to the ventricular ectopic beat (VEB) and supraventricular ectopic beat (SVEB). Methods Based on the different characteristics of VEB and SVEB, a novel hierarchical heartbeat classification system was constructed. This was done in order to improve the classification performance of these two classes of heartbeats by using different features and classification methods. First, random projection and support vector machine (SVM) ensemble were used to detect VEB. Then, the ratio of the RR interval was compared to a predetermined threshold to detect SVEB. The optimal parameters for the classification models were selected on the training set and used in the independent testing set to assess the final performance of the classification system. Meanwhile, the effect of different lead configurations on the classification results was evaluated. Results Results showed that the performance of this classification system was notably superior to that of other methods. The VEB detection sensitivity was 93.9% with a positive predictive value of 90.9%, and the SVEB detection sensitivity was 91.1% with a positive predictive value of 42.2%. In addition, this classification process was relatively fast. Conclusions A hierarchical heartbeat classification system was proposed based on the inter-patient data division to detect VEB and SVEB. It demonstrated better classification performance than existing methods. It can be regarded as a promising system for detecting VEB and SVEB of unknown patients in clinical practice. PMID:24981916
A Sensor System for Detection of Hull Surface Defects
Navarro, Pedro; Iborra, Andrés; Fernández, Carlos; Sánchez, Pedro; Suardíaz, Juan
2010-01-01
This paper presents a sensor system for detecting defects in ship hull surfaces. The sensor was developed to enable a robotic system to perform grit blasting operations on ship hulls. To achieve this, the proposed sensor system captures images with the help of a camera and processes them in real time using a new defect detection method based on thresholding techniques. What makes this method different is its efficiency in the automatic detection of defects from images recorded in variable lighting conditions. The sensor system was tested under real conditions at a Spanish shipyard, with excellent results. PMID:22163590
Munirah, S; Samsudin, O C; Chen, H C; Salmah, S H Sharifah; Aminuddin, B S; Ruszymah, B H I
2008-07-01
Chondrocytes were isolated from articular cartilage biopsy and were cultivated in vitro. Approximately 30 million of cultured chondrocytes per ml were incorporated with autologous plasma-derived fibrin to form three-dimensional construct. Full-thickness punch hole defects were created in lateral and medial femoral condyles. The defects were implanted either with the autologous 'chondrocytes-fibrin' construct (ACFC), autologous chondrocytes (ACI) or fibrin blank (AF). Sheep were euthanized after 12 weeks. The gross morphology of all defects treated with ACFC implantation, ACI and AF exhibited median scores which correspond to a nearly normal appearance according to the International Cartilage Repair Society (ICRS) classification. ACFC significantly enhanced cartilage repair compared to ACI and AF in accordance with the modified O'Driscoll histological scoring scale. The relative sulphated glycosaminoglycans content (%) was significantly higher (p < 0.05) in ACFC when compared to control groups; ACI vs. fibrin only vs. untreated (blank). Results showed that ACFC implantation exhibited superior cartilage-like tissue regeneration compared to ACI. If the result is applicable to the human, it possibly will improve the existing treatment approaches for cartilage restoration in orthopaedic surgery.
An assessment of maintainability of elevator system to improve facilities management knowledge-base
NASA Astrophysics Data System (ADS)
Siti, N. A.; Asmone, A. S.; Chew, M. Y. L.
2018-02-01
Elevator system is a highly specialized machinery that requires technicians that have a wider array of knowledge in maintaining the system to be safe and reliable. While attaining reliable data of elevator malfunction become challenges, this study has filled the gap by gathering the management-maintenance issues and operational defects of elevator system. Forty-three types of operation defects were found and the consequence defects and their possible causes of occurrences were discussed. To respond to the prime challenges of maintaining elevator system provided by the industry players’ perspective, a theoretical framework is established as a recommendation to improve knowledge base of defects in elevator system which comprises good practices, and solutions to rectify each defects found. Hence, this research paper has theoretically improved the knowledge base of maintainability of elevator system and provide meaningful guidelines in practical senses to the industry professionals.
Sultan, Torky; Khedr, Ayman E; Sayed, Mostafa
2013-01-01
NONE DECLARED Defect tracking systems play an important role in the software development organizations as they can store historical information about defects. There are many research in defect tracking models and systems to enhance their capabilities to be more specifically tracking, and were adopted with new technology. Furthermore, there are different studies in classifying bugs in a step by step method to have clear perception and applicable method in detecting such bugs. This paper shows a new proposed defect tracking model for the purpose of classifying the inserted defects reports in a step by step method for more enhancement of the software quality.
Extensions to the Speech Disorders Classification System (SDCS)
ERIC Educational Resources Information Center
Shriberg, Lawrence D.; Fourakis, Marios; Hall, Sheryl D.; Karlsson, Heather B.; Lohmeier, Heather L.; McSweeny, Jane L.; Potter, Nancy L.; Scheer-Cohen, Alison R.; Strand, Edythe A.; Tilkens, Christie M.; Wilson, David L.
2010-01-01
This report describes three extensions to a classification system for paediatric speech sound disorders termed the Speech Disorders Classification System (SDCS). Part I describes a classification extension to the SDCS to differentiate motor speech disorders from speech delay and to differentiate among three sub-types of motor speech disorders.…
A vibroacoustic diagnostic system as an element improving road transport safety.
Komorska, Iwona
2013-01-01
Mechanical defects of a vehicle driving system can be dangerous on the road. Diagnostic systems, which monitor operations of electric and electronic elements and devices of vehicles, are continuously developed and improved, while defects of mechanical systems are still not managed properly. This article proposes supplementing existing on-board diagnostics with a system of diagnosing selected defects to minimize their impact. It presents a method of diagnosing mechanical defects of the engine, gearbox and other elements of the driving system on the basis of a model of the vibration signal obtained adaptively. This method is suitable for engine valves, engine head gasket, main gearbox, joints, etc.
Comparison of Danish dichotomous and BI-RADS classifications of mammographic density.
Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My; Vejborg, Ilse; Andersen, Zorana Jovanovic
2014-06-01
In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. To compare the Danish dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. Of the 120 women, 32 (26.7%) were classified as having fatty and 88 (73.3%) as mixed/dense mammographic density, according to Danish dichotomous classification. According to BI-RADS density classification, 12 (10.0%) women were classified as having predominantly fatty (BI-RADS code 1), 46 (38.3%) as having scattered fibroglandular (BI-RADS code 2), 57 (47.5%) as having heterogeneously dense (BI-RADS 3), and five (4.2%) as having extremely dense (BI-RADS code 4) mammographic density. The inter-rater variability assessed by weighted kappa statistic showed a substantial agreement (0.75). The dichotomous mammographic density classification system utilized in early years of Copenhagen's mammographic screening program (1991-2001) agreed well with the BI-RADS density classification system.
Muth-Köhne, Elke; Wichmann, Arne; Delov, Vera; Fenske, Martina
2012-07-01
Rodents are widely used to test the developmental neurotoxicity potential of chemical substances. The regulatory test procedures are elaborate and the requirement of numerous animals is ethically disputable. Therefore, non-animal alternatives are highly desirable, but appropriate test systems that meet regulatory demands are not yet available. Hence, we have developed a new developmental neurotoxicity assay based on specific whole-mount immunostainings of primary and secondary motor neurons (using the monoclonal antibodies znp1 and zn8) in zebrafish embryos. By classifying the motor neuron defects, we evaluated the severity of the neurotoxic damage to individual primary and secondary motor neurons caused by chemical exposure and determined the corresponding effect concentration values (EC₅₀). In a proof-of-principle study, we investigated the effects of three model compounds thiocyclam, cartap and disulfiram, which show some neurotoxicity-indicating effects in vertebrates, and the positive controls ethanol and nicotine and the negative controls 3,4-dichloroaniline (3,4-DCA) and triclosan. As a quantitative measure of the neurotoxic potential of the test compounds, we calculated the ratios of the EC₅₀ values for motor neuron defects and the cumulative malformations, as determined in a zebrafish embryo toxicity test (zFET). Based on this index, disulfiram was classified as the most potent and thiocyclam as the least potent developmental neurotoxin. The index also confirmed the control compounds as positive and negative neurotoxicants. Our findings demonstrate that this index can be used to reliably distinguish between neurotoxic and non-neurotoxic chemicals and provide a sound estimate for the neurodevelopmental hazard potential of a chemical. The demonstrated method can be a feasible approach to reduce the number of animals used in developmental neurotoxicity evaluation procedures. Copyright © 2012 Elsevier Inc. All rights reserved.
Dental enamel defect diagnosis through different technology-based devices.
Kobayashi, Tatiana Yuriko; Vitor, Luciana Lourenço Ribeiro; Carrara, Cleide Felício Carvalho; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Oliveira, Thais Marchini
2018-06-01
Dental enamel defects (DEDs) are faulty or deficient enamel formations of primary and permanent teeth. Changes during tooth development result in hypoplasia (a quantitative defect) and/or hypomineralisation (a qualitative defect). To compare technology-based diagnostic methods for detecting DEDs. Two-hundred and nine dental surfaces of anterior permanent teeth were selected in patients, 6-11 years of age, with cleft lip with/without cleft palate. First, a conventional clinical examination was conducted according to the modified Developmental Defects of Enamel Index (DDE Index). Dental surfaces were evaluated using an operating microscope and a fluorescence-based device. Interexaminer reproducibility was determined using the kappa test. To compare groups, McNemar's test was used. Cramer's V test was used for comparing the distribution of index codes obtained after classification of all dental surfaces. Cramer's V test revealed statistically significant differences (P < .0001) in the distribution of index codes obtained using the different methods; the coefficients were 0.365 for conventional clinical examination versus fluorescence, 0.961 for conventional clinical examination versus operating microscope and 0.358 for operating microscope versus fluorescence. The sensitivity of the operating microscope and fluorescence method was statistically significant (P = .008 and P < .0001, respectively). Otherwise, the results did not show statistically significant differences in accuracy and specificity for either the operating microscope or the fluorescence methods. This study suggests that the operating microscope performed better than the fluorescence-based device and could be an auxiliary method for the detection of DEDs. © 2017 FDI World Dental Federation.
Mone, Fionnuala; Walsh, Colin; Mulcahy, Cecelia; McMahon, Colin J; Farrell, Sinead; MacTiernan, Aoife; Segurado, Ricardo; Mahony, Rhona; Higgins, Shane; Carroll, Stephen; McParland, Peter; McAuliffe, Fionnuala M
2015-06-01
The aim of this study is to document the detection of fetal congenital heart defect (CHD) in relation to the following: (1) indication for referral, (2) chromosomal and (3) extracardiac abnormalities. All fetal echocardiograms performed in our institution from 2007 to 2011 were reviewed retrospectively. Indication for referral, cardiac diagnosis based on the World Health Organization International Classification of Diseases tenth revision criteria and the presence of chromosomal and extracardiac defects were recorded. Of 1262 echocardiograms, 287 (22.7%) had CHD. Abnormal anatomy scan in pregnancies originally considered to be at low risk of CHD was the best indicator for detecting CHD (91.2% of positive cardiac diagnoses), compared with other indications of family history (5.6%) or maternal medical disorder (3.1%). Congenital anomalies of the cardiac septa comprised the largest category (n = 89), within which atrioventricular septal defects were the most common anomaly (n = 36). Invasive prenatal testing was performed for 126 of 287 cases, of which 44% (n = 55) had a chromosomal abnormality. Of 232 fetuses without chromosomal abnormalities, 31% had an extracardiac defect (n = 76). Most CHDs occur in pregnancies regarded to be at low risk, highlighting the importance of a routine midtrimester fetal anatomy scan. Frequent association of fetal CHD and chromosomal and extracardiac pathology emphasises the importance of thorough evaluation of any fetus with CHD. © 2015 John Wiley & Sons, Ltd.
Dobbs, Bruce M; Cazzell, Shawn M; Dini, Monara
2011-01-01
Osteochondral lesions of the talus have been documented, reported, and studied since as early as the 19th century. The evolution of classification systems has allowed surgeons to better manage osseous lesions. Most osteochondral lesions of the talus have been categorized as anterolateral, posteromedial, or central with respect to the talar dome and its articulating surface. The complexity of the aforementioned lesions each present their own set of obstacles and, hence, management. Specifically, surgery on a central talar dome lesion is complicated by poor exposure and limited access, proving to be a challenging operation. Preoperative planning, including exhaustive imaging before any talar dome surgery, is imperative. We present a case study that involves the need for a distal tibial chevron (wedge) talus, with incorporation of a cadaveric allograft to fill the defect.
Four Pillars for Improving the Quality of Safety-Critical Software-Reliant Systems
2013-04-01
Studies of safety-critical software-reliant systems developed using the current practices of build-then-test show that requirements and architecture ... design defects make up approximately 70% of all defects, many system level related to operational quality attributes, and 80% of these defects are
Defect inspection of actuator lenses using swept-source optical coherence tomography
NASA Astrophysics Data System (ADS)
Lee, Jaeyul; Shirazi, Muhammad Faizan; Park, Kibeom; Jeon, Mansik; Kim, Jeehyun
2017-12-01
Actuator lens industries have gained an enormous interest with the enhancement of various latest communication devices, such as mobile phone and notebooks. The quality of the aforementioned devices can be degraded due to the internal defects of actuator lenses. Therefore, in this study, we implemented swept-source optical coherence tomography (SS-OCT) system to inspect defects of actuator lenses. Owing to the high-resolution of the SS-OCT system, defected foreign substances between the actuator lenses, defective regions of lenses and surface stains were more clearly distinguished through three-dimensional (3D) and two-dimensional (2D) cross-sectional OCT images. Therefore, the implemented SS-OCT system can be considered as a potential application to defect inspection of actuator lens.
Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei
2015-12-01
Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.
Prototype Expert System for Climate Classification.
ERIC Educational Resources Information Center
Harris, Clay
Many students find climate classification laborious and time-consuming, and through their lack of repetition fail to grasp the details of classification. This paper describes an expert system for climate classification that is being developed at Middle Tennessee State University. Topics include: (1) an introduction to the nature of classification,…
NASA Astrophysics Data System (ADS)
Rana, Narender; Chien, Chester
2018-03-01
A key sensor element in a Hard Disk Drive (HDD) is the read-write head device. The device is complex 3D shape and its fabrication requires over thousand process steps with many of them being various types of image inspection and critical dimension (CD) metrology steps. In order to have high yield of devices across a wafer, very tight inspection and metrology specifications are implemented. Many images are collected on a wafer and inspected for various types of defects and in CD metrology the quality of image impacts the CD measurements. Metrology noise need to be minimized in CD metrology to get better estimate of the process related variations for implementing robust process controls. Though there are specialized tools available for defect inspection and review allowing classification and statistics. However, due to unavailability of such advanced tools or other reasons, many times images need to be manually inspected. SEM Image inspection and CD-SEM metrology tools are different tools differing in software as well. SEM Image inspection and CD-SEM metrology tools are separate tools differing in software and purpose. There have been cases where a significant numbers of CD-SEM images are blurred or have some artefact and there is a need for image inspection along with the CD measurement. Tool may not report a practical metric highlighting the quality of image. Not filtering CD from these blurred images will add metrology noise to the CD measurement. An image classifier can be helpful here for filtering such data. This paper presents the use of artificial intelligence in classifying the SEM images. Deep machine learning is used to train a neural network which is then used to classify the new images as blurred and not blurred. Figure 1 shows the image blur artefact and contingency table of classification results from the trained deep neural network. Prediction accuracy of 94.9 % was achieved in the first model. Paper covers other such applications of the deep neural network in image classification for inspection, review and metrology.
5 CFR 9901.221 - Classification requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 9901.221 Administrative Personnel DEPARTMENT OF DEFENSE HUMAN RESOURCES MANAGEMENT AND LABOR RELATIONS SYSTEMS (DEPARTMENT OF DEFENSE-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF DEFENSE NATIONAL SECURITY PERSONNEL SYSTEM (NSPS) Classification Classification Process § 9901.221 Classification...
5 CFR 9701.221 - Classification requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 9701.221 Administrative Personnel DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.221 Classification...
5 CFR 9701.221 - Classification requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 9701.221 Administrative Personnel DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.221 Classification...
5 CFR 9701.221 - Classification requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 9701.221 Administrative Personnel DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.221 Classification...
5 CFR 9701.221 - Classification requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 9701.221 Administrative Personnel DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.221 Classification...
Martín-Biedma, Benjamín; Varela-Patiño, Purificación; Ruíz-Piñón, Manuel; Castelo-Baz, Pablo
2017-01-01
Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-crack generated at the point of maximum canal curvature. Material and Methods 60 human mandibular premolars with curvatures between 30–49° and radii between 2–4 mm were used. The root canals were instrumented using the Protaper Universal® and Protaper NEXT® systems, with the aid of the Proglider® system. The obtained samples were sectioned transversely before subsequent analysis with LED transillumination at 2 mm and 8 mm from the apex and at the point of maximum canal curvature. Defects were scored: 0 for no defects; and 1 for micro-cracks. Results Root defects were not observed in the control group. The ProTaper NEXT system caused fewer defects (16.7%) than the ProTaper Universal system (40%) (P<0.05). The ProTaper Universal system caused significantly more micro-cracks at the point of maximum canal curvature than the ProTaper NEXT system (P<0.05). Conclusions Rotary instrumentation systems often generate root defects, but the ProTaper NEXT system generated fewer dentinal defects than the ProTaper Universal system. A higher prevalence of defects was found at the point of maximum curvature in the ProTaper Universal group. Key words:Curved root, Micro-crack, point of maximum canal curvature, ProTaper NEXT, ProTaper Universal, Vertical root fracture. PMID:29167712
NASA Astrophysics Data System (ADS)
Fitriana, R.; Saragih, J.; Luthfiana, N.
2017-12-01
R Bakery company is a company that produces bread every day. Products that produced in that company have many different types of bread. Products are made in the form of sweet bread and wheat bread which have different tastes for every types of bread. During the making process, there were defects in the products which the defective product turns into reject product. Types of defects that are produced include burnt, sodden bread and shapeless bread. To find out the information about the defects that have been produced then by applying a designed model business intelligence system to create database and data warehouse. By using model business Intelligence system, it will generate useful information such as how many defect that produced by each of the bakery products. To make it easier to obtain such information, it can be done by using data mining method which data that we get is deep explored. The method of data mining is using k-means clustering method. The results of this intelligence business model system are cluster 1 with little amount of defect, cluster 2 with medium amount of defect and cluster 3 with high amount of defect. From OLAP Cube method can be seen that the defect generated during the 7 months period of 96,744 pieces.
The capability of lithography simulation based on MVM-SEM® system
NASA Astrophysics Data System (ADS)
Yoshikawa, Shingo; Fujii, Nobuaki; Kanno, Koichi; Imai, Hidemichi; Hayano, Katsuya; Miyashita, Hiroyuki; Shida, Soichi; Murakawa, Tsutomu; Kuribara, Masayuki; Matsumoto, Jun; Nakamura, Takayuki; Matsushita, Shohei; Hara, Daisuke; Pang, Linyong
2015-10-01
The 1Xnm technology node lithography is using SMO-ILT, NTD or more complex pattern. Therefore in mask defect inspection, defect verification becomes more difficult because many nuisance defects are detected in aggressive mask feature. One key Technology of mask manufacture is defect verification to use aerial image simulator or other printability simulation. AIMS™ Technology is excellent correlation for the wafer and standards tool for defect verification however it is difficult for verification over hundred numbers or more. We reported capability of defect verification based on lithography simulation with a SEM system that architecture and software is excellent correlation for simple line and space.[1] In this paper, we use a SEM system for the next generation combined with a lithography simulation tool for SMO-ILT, NTD and other complex pattern lithography. Furthermore we will use three dimension (3D) lithography simulation based on Multi Vision Metrology SEM system. Finally, we will confirm the performance of the 2D and 3D lithography simulation based on SEM system for a photomask verification.
High-speed autoverifying technology for printed wiring boards
NASA Astrophysics Data System (ADS)
Ando, Moritoshi; Oka, Hiroshi; Okada, Hideo; Sakashita, Yorihiro; Shibutani, Nobumi
1996-10-01
We have developed an automated pattern verification technique. The output of an automated optical inspection system contains many false alarms. Verification is needed to distinguish between minor irregularities and serious defects. In the past, this verification was usually done manually, which led to unsatisfactory product quality. The goal of our new automated verification system is to detect pattern features on surface mount technology boards. In our system, we employ a new illumination method, which uses multiple colors and multiple direction illumination. Images are captured with a CCD camera. We have developed a new algorithm that uses CAD data for both pattern matching and pattern structure determination. This helps to search for patterns around a defect and to examine defect definition rules. These are processed with a high speed workstation and a hard-wired circuits. The system can verify a defect within 1.5 seconds. The verification system was tested in a factory. It verified 1,500 defective samples and detected all significant defects with only a 0.1 percent of error rate (false alarm).
The Bellevue Classification System: nursing's voice upon the library shelves*†
Mages, Keith C
2011-01-01
This article examines the inspiration, construction, and meaning of the Bellevue Classification System (BCS), created during the 1930s for use in the Bellevue School of Nursing Library. Nursing instructor Ann Doyle, with assistance from librarian Mary Casamajor, designed the BCS after consulting with library leaders and examining leading contemporary classification systems, including the Dewey Decimal Classification and Library of Congress, Ballard, and National Health Library classification systems. A close textual reading of the classes, subclasses, and subdivisions of these classification systems against those of the resulting BCS, reveals Doyle's belief that the BCS was created not only to organize the literature, but also to promote the burgeoning intellectualism and professionalism of early twentieth-century American nursing. PMID:21243054
Estevez-Ordonez, Dagoberto; Dewan, Michael C; Feldman, Michael J; Montalvan-Sanchez, Eleazar E; Montalvan-Sanchez, Daniela M; Rodriguez-Murillo, Aida A; Urrutia-Argueta, Samuel A; Cherry, Charlotte B; Morgan, Douglas R; Alvarez-Rodriguez, Roberto; Bonfield, Christopher M
2017-11-01
Central nervous system (CNS) malformations, including neural tube defects (NTDs), are the second most common type of birth defects worldwide and are major causes of childhood disability and mortality. We report the first analysis of birth prevalence in Western Honduras of CNS malformations including NTDs over 6 consecutive years. Data from all patients with congenital CNS malformations and total live births for the period 2010-2015 were obtained through institution and regional registries from all 3 public referral hospitals in Western Honduras, representing 67 municipalities. Cases were identified using the International Classification of Diseases, Tenth Revision CNS malformation codes. Birth prevalence was calculated as cases per 10,000 live births. From 123,903 live births, 275 cases of CNS malformations were identified (54% females, 58% NTDs). Six-year birth prevalence of CNS malformations was 13.9-31.1. Spina bifida variants and anencephaly represented 80% and 19% of reported NTDs, respectively. Total 6-year prevalence of NTDs in Western Honduras was 7.0-17.4 over years studied. In 6 municipalities, average prevalence was >30 (maximum 49.0). This is the first study reporting disease burden of CNS malformations in Western Honduras. The nationwide birth prevalence of NTDs in rural Honduras may have decreased since the implementation of prenatal health policies in 2005. However, we identified regions with unexpectedly elevated prevalence, indicating high regional prevalence that could be targeted for improved preventive efforts, ultimately decreasing the burden of these conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
DOT National Transportation Integrated Search
1996-02-01
This study reviewed the low volume road (LVR) classifications in Kansas in conjunction with the State A, B, C, D, E road classification system and addressed alignment of these differences. As an extension to the State system, an F, G, H classificatio...
A novel artificial immune clonal selection classification and rule mining with swarm learning model
NASA Astrophysics Data System (ADS)
Al-Sheshtawi, Khaled A.; Abdul-Kader, Hatem M.; Elsisi, Ashraf B.
2013-06-01
Metaheuristic optimisation algorithms have become popular choice for solving complex problems. By integrating Artificial Immune clonal selection algorithm (CSA) and particle swarm optimisation (PSO) algorithm, a novel hybrid Clonal Selection Classification and Rule Mining with Swarm Learning Algorithm (CS2) is proposed. The main goal of the approach is to exploit and explore the parallel computation merit of Clonal Selection and the speed and self-organisation merits of Particle Swarm by sharing information between clonal selection population and particle swarm. Hence, we employed the advantages of PSO to improve the mutation mechanism of the artificial immune CSA and to mine classification rules within datasets. Consequently, our proposed algorithm required less training time and memory cells in comparison to other AIS algorithms. In this paper, classification rule mining has been modelled as a miltiobjective optimisation problem with predictive accuracy. The multiobjective approach is intended to allow the PSO algorithm to return an approximation to the accuracy and comprehensibility border, containing solutions that are spread across the border. We compared our proposed algorithm classification accuracy CS2 with five commonly used CSAs, namely: AIRS1, AIRS2, AIRS-Parallel, CLONALG, and CSCA using eight benchmark datasets. We also compared our proposed algorithm classification accuracy CS2 with other five methods, namely: Naïve Bayes, SVM, MLP, CART, and RFB. The results show that the proposed algorithm is comparable to the 10 studied algorithms. As a result, the hybridisation, built of CSA and PSO, can develop respective merit, compensate opponent defect, and make search-optimal effect and speed better.
Detection of Partial Discharge Sources Using UHF Sensors and Blind Signal Separation
Boya, Carlos; Parrado-Hernández, Emilio
2017-01-01
The measurement of the emitted electromagnetic energy in the UHF region of the spectrum allows the detection of partial discharges and, thus, the on-line monitoring of the condition of the insulation of electrical equipment. Unfortunately, determining the affected asset is difficult when there are several simultaneous insulation defects. This paper proposes the use of an independent component analysis (ICA) algorithm to separate the signals coming from different partial discharge (PD) sources. The performance of the algorithm has been tested using UHF signals generated by test objects. The results are validated by two automatic classification techniques: support vector machines and similarity with class mean. Both methods corroborate the suitability of the algorithm to separate the signals emitted by each PD source even when they are generated by the same type of insulation defect. PMID:29140267
Net Shape Technology in Aerospace Structures. Volume 1.
1986-11-01
ofI nIo n- destructive evaluation methods, such a s ult rasonic inspection, in detecting otherwise hidden defects in parts made of the material. Pratt...SCHEDULE 4. PERFORMING ORGANIZATION REPORT NUMBER( S ) 5. MONITORING ORGANIZATION REPORT NUMBER( S ) n/a n/a 6a. NAME OF PERFORMING ORGANIZATION 6b...a n/a n/a 11 TITLE (Include Security Classification) Net Shape Technology in Aerospace Structures, Vol. I (U) 12. PERSONAL AUTHOR( S ) 13a. TYPE OF
Role of Water in Proton-Hydroxide Conductance Across Model and Biological Membranes.
1987-11-10
Arlington, VA 22217-5000 61153N RR04108 441K712 11. TITLE (Include Security Classification) Role of water in proton-hydroxide conductance across model and...used the gramicidin channel to test properties of transmembrane strands of hydrogen bonded water which would model such defects. Results are described...Gramicidin as a model "proton wire." 2. Effects of homologous series of alcohols on proton flux in liposomes, and the relationship to their anesthetic
Analysis of the Effects of a gerP Mutation on the Germination of Spores of Bacillus subtilis
2012-11-01
REPORT Analysis of the effects of a gerP mutation on the germination of spores of Bacillus subtilis 14. ABSTRACT 16. SECURITY CLASSIFICATION OF... Bacillus subtilis spores with a gerP mutation triggered spore germination via nutrient germinant receptors (GRs) slowly, although this defect was...gerP, Bacillus subtilis , dipicolinic acid Xuan Y. Butzin, Anthony J. Troiano, William H. Coleman, Keren K. Griffiths, Christopher J. Doona, Florence E
Focused Ion Beam Methods for Research and Control of HEMT Fabrication
NASA Astrophysics Data System (ADS)
Pevtsov, E. Ph; Bespalov, A. V.; Demenkova, T. A.; Luchnikov, P. A.
2017-04-01
The combination of ion-beam spraying and raster electronic microscopy allows to receive images of sections of defects of the growth nature origin in epitaxial films on GaN basis with nanodimensional permission, to carry out their analysis and classification irrespective of conditions of receiving. Results of application of the specified methods for the analysis of technological operations when forming the microwave transistors are considered: formations of locks, receiving of holes and drawing of contacts.
NASA Astrophysics Data System (ADS)
Devillez, Arnaud; Dudzinski, Daniel
2007-01-01
Today the knowledge of a process is very important for engineers to find optimal combination of control parameters warranting productivity, quality and functioning without defects and failures. In our laboratory, we carry out research in the field of high speed machining with modelling, simulation and experimental approaches. The aim of our investigation is to develop a software allowing the cutting conditions optimisation to limit the number of predictive tests, and the process monitoring to prevent any trouble during machining operations. This software is based on models and experimental data sets which constitute the knowledge of the process. In this paper, we deal with the problem of vibrations occurring during a machining operation. These vibrations may cause some failures and defects to the process, like workpiece surface alteration and rapid tool wear. To measure on line the tool micro-movements, we equipped a lathe with a specific instrumentation using eddy current sensors. Obtained signals were correlated with surface finish and a signal processing algorithm was used to determine if a test is stable or unstable. Then, a fuzzy classification method was proposed to classify the tests in a space defined by the width of cut and the cutting speed. Finally, it was shown that the fuzzy classification takes into account of the measurements incertitude to compute the stability limit or stability lobes of the process.
Phase-space topography characterization of nonlinear ultrasound waveforms.
Dehghan-Niri, Ehsan; Al-Beer, Helem
2018-03-01
Fundamental understanding of ultrasound interaction with material discontinuities having closed interfaces has many engineering applications such as nondestructive evaluation of defects like kissing bonds and cracks in critical structural and mechanical components. In this paper, to analyze the acoustic field nonlinearities due to defects with closed interfaces, the use of a common technique in nonlinear physics, based on a phase-space topography construction of ultrasound waveform, is proposed. The central idea is to complement the "time" and "frequency" domain analyses with the "phase-space" domain analysis of nonlinear ultrasound waveforms. A nonlinear time series method known as pseudo phase-space topography construction is used to construct equivalent phase-space portrait of measured ultrasound waveforms. Several nonlinear models are considered to numerically simulate nonlinear ultrasound waveforms. The phase-space response of the simulated waveforms is shown to provide different topographic information, while the frequency domain shows similar spectral behavior. Thus, model classification can be substantially enhanced in the phase-space domain. Experimental results on high strength aluminum samples show that the phase-space transformation provides a unique detection and classification capabilities. The Poincaré map of the phase-space domain is also used to better understand the nonlinear behavior of ultrasound waveforms. It is shown that the analysis of ultrasound nonlinearities is more convenient and informative in the phase-space domain than in the frequency domain. Copyright © 2017 Elsevier B.V. All rights reserved.
Value of Defect Information in Automated Hardwood Edger and Trimmer Systems
Carmen Regalado; D. Earl Kline; Philip A. Araman
1992-01-01
Due to the limited capability of board defect scanners, not all defect information required to make the best edging and trimming decision can be scanned for use in an automated system. The objective of the study presented in this paper was to evaluate the lumber value obtainable from edging and trimming optimization using varying levels of defect information as input....
NASA Astrophysics Data System (ADS)
Guo, Hualing; Zheng, Bin; Liu, Hui
2017-11-01
In the present research, the mechanism governing the interaction between laser-generated ultrasonic wave and the micro-defects on an aluminum plate has been studied by virtue of numerical simulation as well as practical experiments. Simulation results indicate that broadband ultrasonic waves are caused mainly by surface waves, and that the surface waves produced by micro-defects could be utilized for the detection of micro-defects because these waves reflect as much information of the defects as possible. In the research, a laser-generated ultrasonic wave testing system with a surface wave probe has been established for the detection of micro-defects, and the surface waves produced by the defects with different depths on an aluminum plate have been tested by using the system. The interaction between defect depth and the maximum amplitude of the surface wave and that between defect depth and the center frequency of the surface wave have also been analyzed in detail. Research results indicate that, when the defect depth is less than half of the wavelength of the surface wave, the maximum amplitude and the center frequency of the surface wave are in linear proportion to the defect depth. Sound consistency of experimental results with theoretical simulation indicates that the system as established in the present research could be adopted for the quantitative detection of micro-defects.
NASA Astrophysics Data System (ADS)
Sopori, Bhushan; Wei, Chen; Yi, Zhang; Madjdpour, Jamal
2000-03-01
A scanning system for mapping defects, and for measuring their influence on the photovoltaic of Si solar cells, is described. The system uses optical scattering patterns to identify the nature of defects. The local density of the defects is statistically determined from the integrated scattered light. The optical system can also measure the reflectance and the light-induced current which is then used to yield maps of the internal photoresponse of the device.
Khedr, Ayman E.; Sayed, Mostafa
2013-01-01
CONFLICT OF INTEREST: NONE DECLARED Defect tracking systems play an important role in the software development organizations as they can store historical information about defects. There are many research in defect tracking models and systems to enhance their capabilities to be more specifically tracking, and were adopted with new technology. Furthermore, there are different studies in classifying bugs in a step by step method to have clear perception and applicable method in detecting such bugs. This paper shows a new proposed defect tracking model for the purpose of classifying the inserted defects reports in a step by step method for more enhancement of the software quality. PMID:24039334
Automatic cross-sectioning and monitoring system locates defects in electronic devices
NASA Technical Reports Server (NTRS)
Jacobs, G.; Slaughter, B.
1971-01-01
System consists of motorized grinding and lapping apparatus, sample holder, and electronic control circuit. Low power microscope examines device to pinpoint location of circuit defect, and monitor displays output signal when defect is located exactly.
The functionalization of carbon nanosheets
NASA Astrophysics Data System (ADS)
Quinlan, Ronald A.
Carbon nanosheets are a novel two-dimensional nanostructure made up of 2-20 graphene atomic planes oriented with their in-plane axis perpendicular to the growth substrate. Previous efforts in developing nanosheet technology have focused on the characterization of the system and their development as an electron source due to the high atomic enhancement factor (beta) and low turn on field. Further investigation of nanosheets as high surface area electrodes revealed poor wetting by polymeric material and extreme hydrophobic behavior. Because nanosheet technology has promise as a high surface area electrode material, this thesis research has focused on three areas of interest: the enhancement of nanosheets through chemical modification, the incorporation of the nanosheets into a polymeric composite and the delivery of a proof of concept measurement. We have successfully introduced defects into the graphene lattice of the nanosheet system via an acid treatment. Inspection of these defects by x-ray absorption near-edge spectroscopy (XANES) shows the introduction of two features in the spectra assigned to C=O pi* and C-O sigma* transitions. Thermal desorption spectroscopy (TDS) was used to identify the oxygen containing groups created during the functionalization as carboxylic and hydroxyl functional groups. These groups were identified through the combination of carboxylic, hydroxyl, anhydride and lactone peaks in the CO2, CO and H 2O TDS spectra. Deconvolution of the TDS spectra using 1st and 2nd order Polanyi-Wigner equations enables the calculation of desorption energy values for individual features and for the estimation of the number of atoms desorbing from the surface during a particular event. Identification of the exact nature of the functional groups was attempted through high resolution x-ray photoelectron spectroscopy (XPS) of the C(1s) and O(1s) peaks. Though the pairing of sub-peaks with specific functionalities of the system was not possible due to the complexities of the spectra, the trends observed in the data support the data gathered via the XANES and TDS experiments. Also, a procedure for the classification of defect density and exact functionality was outlined. Deconvolution of the TDS spectra using 1 st and 2nd order Polanyi-Wigner equations enabled the calculation of desorption energy values for individual features and for the estimation of the number of atoms desorbing from the surface during a particular event. This information along with the changing sub-peak areas from dedicated and calibrated XPS system would allow for not only a more accurate estimation of defect density, but also for the identification of sub-peaks in the C(1s) and O(1s) spectra. Finally, photoluminescence measurements of poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV) and MEH-PPV/nanosheet systems showed a quenching of three orders of magnitude for the MEH-PPV/nanosheet system suggesting that nanosheets are a viable option for excition separation in organic photovoltaics.
A scanning defect mapping system for semiconductor characterization
NASA Technical Reports Server (NTRS)
Sopori, Bushnan L.
1994-01-01
We have developed an optical scanning system that generates maps of the spatial distributions of defects in single and polycrystalline silicon wafers. This instrument, called Scanning Defect Mapping System, utilizes differences in the scattering characteristics of dislocation etch pits and grain boundaries from a defect-etched sample to identify and count them. This system simultaneously operates in the dislocation mode and the grain boundary (GB) mode. In the 'dislocation mode,' the optical scattering from the etch pits is used to statistically count dislocations, while ignoring the GB's. Likewise, in the 'grain boundary mode' the system only recognizes the local scattering from the GB's to generate grain boundary distributions. The information generated by this instrument is valuable for material quality control, identifying mechanisms of defect generation and the nature of thermal stresses during the crystal growth, and the solar cell process design.
Sato, Takahiro; Orai, Yoshihisa; Suzuki, Yuya; Ito, Hiroyuki; Isshiki, Toshiyuki; Fukui, Munetoshi; Nakamura, Kuniyasu; Schamp, C T
2017-10-01
To improve the reliability of silicon carbide (SiC) electronic power devices, the characteristics of various kinds of crystal defects should be precisely understood. Of particular importance is understanding the correlation between the surface morphology and the near surface dislocations. In order to analyze the dislocations near the surface of 4H-SiC wafers, a dislocation analysis protocol has been developed. This protocol consists of the following process: (1) inspection of surface defects using low energy scanning electron microscopy (LESEM), (2) identification of small and shallow etch pits using KOH low temperature etching, (3) classification of etch pits using LESEM, (4) specimen preparation of several hundred nanometer thick sample using the in-situ focused ion beam micro-sampling® technique, (5) crystallographic analysis using the selected diffraction mode of the scanning transmission electron microscope (STEM), and (6) determination of the Burgers vector using multi-directional STEM (MD-STEM). The results show a correlation between the triangular terrace shaped surface defects and an hexagonal etch pit arising from threading dislocations, linear shaped surface defects and elliptical shaped etch pits arising from basal plane dislocations. Through the observation of the sample from two orthogonal directions via the MD-STEM technique, a basal plane dislocation is found to dissociate into an extended dislocation bound by two partial dislocations. A protocol developed and presented in this paper enables one to correlate near surface defects of a 4H-SiC wafer with the root cause dislocations giving rise to those surface defects. © The Author 2017. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
MECHANISMS IN ENDOCRINOLOGY: Novel genetic causes of short stature.
Wit, Jan M; Oostdijk, Wilma; Losekoot, Monique; van Duyvenvoorde, Hermine A; Ruivenkamp, Claudia A L; Kant, Sarina G
2016-04-01
The fast technological development, particularly single nucleotide polymorphism array, array-comparative genomic hybridization, and whole exome sequencing, has led to the discovery of many novel genetic causes of growth failure. In this review we discuss a selection of these, according to a diagnostic classification centred on the epiphyseal growth plate. We successively discuss disorders in hormone signalling, paracrine factors, matrix molecules, intracellular pathways, and fundamental cellular processes, followed by chromosomal aberrations including copy number variants (CNVs) and imprinting disorders associated with short stature. Many novel causes of GH deficiency (GHD) as part of combined pituitary hormone deficiency have been uncovered. The most frequent genetic causes of isolated GHD are GH1 and GHRHR defects, but several novel causes have recently been found, such as GHSR, RNPC3, and IFT172 mutations. Besides well-defined causes of GH insensitivity (GHR, STAT5B, IGFALS, IGF1 defects), disorders of NFκB signalling, STAT3 and IGF2 have recently been discovered. Heterozygous IGF1R defects are a relatively frequent cause of prenatal and postnatal growth retardation. TRHA mutations cause a syndromic form of short stature with elevated T3/T4 ratio. Disorders of signalling of various paracrine factors (FGFs, BMPs, WNTs, PTHrP/IHH, and CNP/NPR2) or genetic defects affecting cartilage extracellular matrix usually cause disproportionate short stature. Heterozygous NPR2 or SHOX defects may be found in ∼3% of short children, and also rasopathies (e.g., Noonan syndrome) can be found in children without clear syndromic appearance. Numerous other syndromes associated with short stature are caused by genetic defects in fundamental cellular processes, chromosomal abnormalities, CNVs, and imprinting disorders. © 2016 European Society of Endocrinology.
Classifications of Acute Scaphoid Fractures: A Systematic Literature Review.
Ten Berg, Paul W; Drijkoningen, Tessa; Strackee, Simon D; Buijze, Geert A
2016-05-01
Background In the lack of consensus, surgeon-based preference determines how acute scaphoid fractures are classified. There is a great variety of classification systems with considerable controversies. Purposes The purpose of this study was to provide an overview of the different classification systems, clarifying their subgroups and analyzing their popularity by comparing citation indexes. The intention was to improve data comparison between studies using heterogeneous fracture descriptions. Methods We performed a systematic review of the literature based on a search of medical literature from 1950 to 2015, and a manual search using the reference lists in relevant book chapters. Only original descriptions of classifications of acute scaphoid fractures in adults were included. Popularity was based on citation index as reported in the databases of Web of Science (WoS) and Google Scholar. Articles that were cited <10 times in WoS were excluded. Results Our literature search resulted in 308 potentially eligible descriptive reports of which 12 reports met the inclusion criteria. We distinguished 13 different (sub) classification systems based on (1) fracture location, (2) fracture plane orientation, and (3) fracture stability/displacement. Based on citations numbers, the Herbert classification was most popular, followed by the Russe and Mayo classifications. All classification systems were based on plain radiography. Conclusions Most classification systems were based on fracture location, displacement, or stability. Based on the controversy and limited reliability of current classification systems, suggested research areas for an updated classification include three-dimensional fracture pattern etiology and fracture fragment mobility assessed by dynamic imaging.
Holographic Chern-Simons defects
Fujita, Mitsutoshi; Melby-Thompson, Charles M.; Meyer, René; ...
2016-06-28
Here, we study SU(N ) Yang-Mills-Chern-Simons theory in the presence of defects that shift the Chern-Simons level from a holographic point of view by embedding the system in string theory. The model is a D3-D7 system in Type IIB string theory, whose gravity dual is given by the AdS soliton background with probe D7 branes attaching to the AdS boundary along the defects. We holographically renormalize the free energy of the defect system with sources, from which we obtain the correlation functions for certain operators naturally associated to these defects. We find interesting phase transitions when the separation of themore » defects as well as the temperature are varied. We also discuss some implications for the Fractional Quantum Hall Effect and for 2-dimensional QCD.« less
Classification of close binary systems by Svechnikov
NASA Astrophysics Data System (ADS)
Dryomova, G. N.
The paper presents the historical overview of classification schemes of eclipsing variable stars with the foreground of advantages of the classification scheme by Svechnikov being widely appreciated for Close Binary Systems due to simplicity of classification criteria and brevity.
Recursive heuristic classification
NASA Technical Reports Server (NTRS)
Wilkins, David C.
1994-01-01
The author will describe a new problem-solving approach called recursive heuristic classification, whereby a subproblem of heuristic classification is itself formulated and solved by heuristic classification. This allows the construction of more knowledge-intensive classification programs in a way that yields a clean organization. Further, standard knowledge acquisition and learning techniques for heuristic classification can be used to create, refine, and maintain the knowledge base associated with the recursively called classification expert system. The method of recursive heuristic classification was used in the Minerva blackboard shell for heuristic classification. Minerva recursively calls itself every problem-solving cycle to solve the important blackboard scheduler task, which involves assigning a desirability rating to alternative problem-solving actions. Knowing these ratings is critical to the use of an expert system as a component of a critiquing or apprenticeship tutoring system. One innovation of this research is a method called dynamic heuristic classification, which allows selection among dynamically generated classification categories instead of requiring them to be prenumerated.
Dijemeni, Esuabom; D'Amone, Gabriele; Gbati, Israel
2017-12-01
Drug-induced sedation endoscopy (DISE) classification systems have been used to assess anatomical findings on upper airway obstruction, and decide and plan surgical treatments and act as a predictor for surgical treatment outcome for obstructive sleep apnoea management. The first objective is to identify if there is a universally accepted DISE grading and classification system for analysing DISE findings. The second objective is to identify if there is one DISE grading and classification treatment planning framework for deciding appropriate surgical treatment for obstructive sleep apnoea (OSA). The third objective is to identify if there is one DISE grading and classification treatment outcome framework for determining the likelihood of success for a given OSA surgical intervention. A systematic review was performed to identify new and significantly modified DISE classification systems: concept, advantages and disadvantages. Fourteen studies proposing a new DISE classification system and three studies proposing a significantly modified DISE classification were identified. None of the studies were based on randomised control trials. DISE is an objective method for visualising upper airway obstruction. The classification and assessment of clinical findings based on DISE is highly subjective due to the increasing number of DISE classification systems. Hence, this creates a growing divergence in surgical treatment planning and treatment outcome. Further research on a universally accepted objective DISE assessment is critically needed.
A New Tool for Climatic Analysis Using the Koppen Climate Classification
ERIC Educational Resources Information Center
Larson, Paul R.; Lohrengel, C. Frederick, II
2011-01-01
The purpose of climate classification is to help make order of the seemingly endless spatial distribution of climates. The Koppen classification system in a modified format is the most widely applied system in use today. This system may not be the best nor most complete climate classification that can be conceived, but it has gained widespread…
Rubber hose surface defect detection system based on machine vision
NASA Astrophysics Data System (ADS)
Meng, Fanwu; Ren, Jingrui; Wang, Qi; Zhang, Teng
2018-01-01
As an important part of connecting engine, air filter, engine, cooling system and automobile air-conditioning system, automotive hose is widely used in automobile. Therefore, the determination of the surface quality of the hose is particularly important. This research is based on machine vision technology, using HALCON algorithm for the processing of the hose image, and identifying the surface defects of the hose. In order to improve the detection accuracy of visual system, this paper proposes a method to classify the defects to reduce misjudegment. The experimental results show that the method can detect surface defects accurately.
Wong, Wai Keat; Shetty, Subhaschandra
2017-08-01
Parotidectomy remains the mainstay of treatment for both benign and malignant lesions of the parotid gland. There exists a wide range of possible surgical options in parotidectomy in terms of extent of parotid tissue removed. There is increasing need for uniformity of terminology resulting from growing interest in modifications of the conventional parotidectomy. It is, therefore, of paramount importance for a standardized classification system in describing extent of parotidectomy. Recently, the European Salivary Gland Society (ESGS) proposed a novel classification system for parotidectomy. The aim of this study is to evaluate this system. A classification system proposed by the ESGS was critically re-evaluated and modified to increase its accuracy and its acceptability. Modifications mainly focused on subdividing Levels I and II into IA, IB, IIA, and IIB. From June 2006 to June 2016, 126 patients underwent 130 parotidectomies at our hospital. The classification system was tested in that cohort of patient. While the ESGS classification system is comprehensive, it does not cover all possibilities. The addition of Sublevels IA, IB, IIA, and IIB may help to address some of the clinical situations seen and is clinically relevant. We aim to test the modified classification system for partial parotidectomy to address some of the challenges mentioned.
Zhou, Renpeng; Wang, Chen; Qian, Yunliang; Wang, Danru
2015-09-01
Facial defects are multicomponent deficiencies rather than simple soft-tissue defects. Based on different branches of the superficial temporal vascular system, various tissue components can be obtained to reconstruct facial defects individually. From January 2004 to December 2013, 31 patients underwent reconstruction of facial defects with composite flaps based on the superficial temporal vascular system. Twenty cases of nasal defects were repaired with skin and cartilage components, six cases of facial defects were treated with double island flaps of the skin and fascia, three patients underwent eyebrow and lower eyelid reconstruction with hairy and hairless flaps simultaneously, and two patients underwent soft-tissue repair with auricular combined flaps and cranial bone grafts. All flaps survived completely. Donor-site morbidity is minimal, closed primarily. Donor areas healed with acceptable cosmetic results. The final outcome was satisfactory. Combined flaps based on the superficial temporal vascular system are a useful and versatile option in facial soft-tissue reconstruction. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Krause, Fabian G; Di Silvestro, Matthew; Penner, Murray J; Wing, Kevin J; Glazebrook, Mark A; Daniels, Timothy R; Lau, Johnny T C; Younger, Alastair S E
2012-02-01
End-stage ankle arthritis is operatively treated with numerous designs of total ankle replacement and different techniques for ankle fusion. For superior comparison of these procedures, outcome research requires a classification system to stratify patients appropriately. A postoperative 4-type classification system was designed by 6 fellowship-trained foot and ankle surgeons. Four surgeons reviewed blinded patient profiles and radiographs on 2 occasions to determine the interobserver and intraobserver reliability of the classification. Excellent interobserver reliability (κ = .89) and intraobserver reproducibility (κ = .87) were demonstrated for the postoperative classification system. In conclusion, the postoperative Canadian Orthopaedic Foot and Ankle Society (COFAS) end-stage ankle arthritis classification system appears to be a valid tool to evaluate the outcome of patients operated for end-stage ankle arthritis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matteson, A.; Morris, R.; Tate, R.
1993-12-31
The acoustic signal produced by the gas metal arc welding (GMAW) arc contains information about the behavior of the arc column, the molten pool and droplet transfer. It is possible to detect some defect producing conditions from the acoustic signal from the GMAW arc. An intelligent sensor, called the Weld Acoustic Monitor (WAM) has been developed to take advantage of this acoustic information in order to provide real-time quality assessment information for process control. The WAM makes use of an Artificial Neural Network (ANN) to classify the characteristic arc acoustic signals of acceptable and unacceptable welds. The ANN used inmore » the Weld Acoustic Monitor developed its own set of rules for this classification problem by learning a data base of known GMAW acoustic signals.« less
Railroad Classification Yard Technology Manual: Volume II : Yard Computer Systems
DOT National Transportation Integrated Search
1981-08-01
This volume (Volume II) of the Railroad Classification Yard Technology Manual documents the railroad classification yard computer systems methodology. The subjects covered are: functional description of process control and inventory computer systems,...
Teratogens: a public health issue – a Brazilian overview
Mazzu-Nascimento, Thiago; Melo, Débora Gusmão; Morbioli, Giorgio Gianini; Carrilho, Emanuel; Vianna, Fernanda Sales Luiz; da Silva, André Anjos; Schuler-Faccini, Lavinia
2017-01-01
Abstract Congenital anomalies are already the second cause of infant mortality in Brazil, as in many other middle-income countries in Latin America. Birth defects are a result of both genetic and environmental factors, but a multifactorial etiology has been more frequently observed. Here, we address the environmental causes of birth defects – or teratogens – as a public health issue and present their mechanisms of action, categories and their respective maternal-fetal deleterious effects. We also present a survey from 2008 to 2013 of Brazilian cases involving congenital anomalies (annual average of 20,205), fetal deaths (annual average of 1,530), infant hospitalizations (annual average of 82,452), number of deaths of hospitalized infants (annual average of 2,175), and the average cost of hospitalizations (annual cost of $7,758). Moreover, we report on Brazilian cases of teratogenesis due to the recent Zika virus infection, and to the use of misoprostol, thalidomide, alcohol and illicit drugs. Special attention has been given to the Zika virus infection, now proven to be responsible for the microcephaly outbreak in Brazil, with 8,039 cases under investigation (from October 2015 to June 2016). From those cases, 1,616 were confirmed and 324 deaths occurred due to microcephaly complications or alterations on the central nervous system. Congenital anomalies impact life quality and raise costs in specialized care, justifying the classification of teratogens as a public health issue. PMID:28534929
Gunshot injuries due to celebratory gun shootings.
Ozdemir, Mevci; Unlü, Ağahan
2009-01-01
Traditional shooting with guns often occurs and leads to unwanted gunshot injuries in areas where celebrations are held. Such injuries have been classified as celebratory gun shooting injury in the international disease classification system. An 8-year-old female patient presented with respiratory arrest. The heartbeats normalized upon cardiopulmonary resuscitation. On physical examination, the only pathological finding was a skin defect measuring 1 x 1 cm on the midline and located 2 cm in front of the coronal suture. Cranial CT revealed a bone defect of 0.5 cm in the area 2 cm in front of the coronal suture on the midline, tetraventricular and extensive subarachnoid hemorrhage and parenchymal hematoma in the frontal area. It was initially thought to be a gunshot injury; however, on cranial CT, no bullet fragments or bullet exit hole was observed. A cervicothoracal direct graph was obtained and an image that might have been compatible with a bullet core was detected at Th 2-3 vertebra level. Although gunshot injuries are generally well- known, this may not be a very familiar topic for neurosurgeons. The primary aim of this report is to emphasize that a bullet round randomly fired into the air ascends in reverse direction to gravity and after reaching a zero point, it returns to the ground at a high velocity that facilitates its penetration into the skull according to a principal physics law.
Cause of and factors associated with stillbirth: a systematic review of classification systems.
Aminu, Mamuda; Bar-Zeev, Sarah; van den Broek, Nynke
2017-05-01
An estimated 2.6 million stillbirths occur worldwide each year. A standardized classification system setting out possible cause of death and contributing factors is useful to help obtain comparative data across different settings. We undertook a systematic review of stillbirth classification systems to highlight their strengths and weaknesses for practitioners and policymakers. We conducted a systematic search and review of the literature to identify the classification systems used to aggregate information for stillbirth and perinatal deaths. Narrative synthesis was used to compare the range and depth of information required to apply the systems, and the different categories provided for cause of and factors contributing to stillbirth. A total of 118 documents were screened; 31 classification systems were included, of which six were designed specifically for stillbirth, 14 for perinatal death, three systems included neonatal deaths and two included infant deaths. Most (27/31) were developed in and first tested using data obtained from high-income settings. All systems required information from clinical records. One-third of the classification systems (11/31) included information obtained from histology or autopsy. The percentage where cause of death remained unknown ranged from 0.39% using the Nordic-Baltic classification to 46.4% using the Keeling system. Over time, classification systems have become more complex. The success of application is dependent on the availability of detailed clinical information and laboratory investigations. Systems that adopt a layered approach allow for classification of cause of death to a broad as well as to a more detailed level. © 2017 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons Ltd on behalf of Nordic Federation of Societies of Obstetrics and Gynecology (NFOG).
Varney, Michael C M; Jenness, Nathan J; Smalyukh, Ivan I
2014-02-01
Despite the recent progress in physical control and manipulation of various condensed matter, atomic, and particle systems, including individual atoms and photons, our ability to control topological defects remains limited. Recently, controlled generation, spatial translation, and stretching of topological point and line defects have been achieved using laser tweezers and liquid crystals as model defect-hosting systems. However, many modes of manipulation remain hindered by limitations inherent to optical trapping. To overcome some of these limitations, we integrate holographic optical tweezers with a magnetic manipulation system, which enables fully holonomic manipulation of defects by means of optically and magnetically controllable colloids used as "handles" to transfer forces and torques to various liquid crystal defects. These colloidal handles are magnetically rotated around determined axes and are optically translated along three-dimensional pathways while mechanically attached to defects, which, combined with inducing spatially localized nematic-isotropic phase transitions, allow for geometrically unrestricted control of defects, including previously unrealized modes of noncontact manipulation, such as the twisting of disclination clusters. These manipulation capabilities may allow for probing topological constraints and the nature of defects in unprecedented ways, providing the foundation for a tabletop laboratory to expand our understanding of the role defects play in fields ranging from subatomic particle physics to early-universe cosmology.
Searching bioremediation patents through Cooperative Patent Classification (CPC).
Prasad, Rajendra
2016-03-01
Patent classification systems have traditionally evolved independently at each patent jurisdiction to classify patents handled by their examiners to be able to search previous patents while dealing with new patent applications. As patent databases maintained by them went online for free access to public as also for global search of prior art by examiners, the need arose for a common platform and uniform structure of patent databases. The diversity of different classification, however, posed problems of integrating and searching relevant patents across patent jurisdictions. To address this problem of comparability of data from different sources and searching patents, WIPO in the recent past developed what is known as International Patent Classification (IPC) system which most countries readily adopted to code their patents with IPC codes along with their own codes. The Cooperative Patent Classification (CPC) is the latest patent classification system based on IPC/European Classification (ECLA) system, developed by the European Patent Office (EPO) and the United States Patent and Trademark Office (USPTO) which is likely to become a global standard. This paper discusses this new classification system with reference to patents on bioremediation.
The investigation of the lateral interaction effect's on traffic flow behavior under open boundaries
NASA Astrophysics Data System (ADS)
Bouadi, M.; Jetto, K.; Benyoussef, A.; El Kenz, A.
2017-11-01
In this paper, an open boundaries traffic flow system is studied by taking into account the lateral interaction with spatial defects. For a random defects distribution, if the vehicles velocities are weakly correlated, the traffic phases can be predicted by considering the corresponding inflow and outflow functions. Conversely, if the vehicles velocities are strongly correlated, a phase segregation appears inside the system's bulk which induces the maximum current appearance. Such velocity correlation depends mainly on the defects densities and the probabilities of lateral deceleration. However, for a compact defects distribution, the traffic phases are predictable by using the inflow in the system beginning, the inflow entering the defects zone and the outflow function.
Ultrasonic sensing of GMAW: Laser/EMAT defect detection system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, N.M.; Johnson, J.A.; Larsen, E.D.
1992-08-01
In-process ultrasonic sensing of welding allows detection of weld defects in real time. A noncontacting ultrasonic system is being developed to operate in a production environment. The principal components are a pulsed laser for ultrasound generation and an electromagnetic acoustic transducer (EMAT) for ultrasound reception. A PC-based data acquisition system determines the quality of the weld on a pass-by-pass basis. The laser/EMAT system interrogates the area in the weld volume where defects are most likely to occur. This area of interest is identified by computer calculations on a pass-by-pass basis using weld planning information provided by the off-line programmer. Themore » absence of a signal above the threshold level in the computer-calculated time interval indicates a disruption of the sound path by a defect. The ultrasonic sensor system then provides an input signal to the weld controller about the defect condition. 8 refs.« less
Kinetic energy classification and smoothing for compact B-spline basis sets in quantum Monte Carlo
Krogel, Jaron T.; Reboredo, Fernando A.
2018-01-25
Quantum Monte Carlo calculations of defect properties of transition metal oxides have become feasible in recent years due to increases in computing power. As the system size has grown, availability of on-node memory has become a limiting factor. Saving memory while minimizing computational cost is now a priority. The main growth in memory demand stems from the B-spline representation of the single particle orbitals, especially for heavier elements such as transition metals where semi-core states are present. Despite the associated memory costs, splines are computationally efficient. In this paper, we explore alternatives to reduce the memory usage of splined orbitalsmore » without significantly affecting numerical fidelity or computational efficiency. We make use of the kinetic energy operator to both classify and smooth the occupied set of orbitals prior to splining. By using a partitioning scheme based on the per-orbital kinetic energy distributions, we show that memory savings of about 50% is possible for select transition metal oxide systems. Finally, for production supercells of practical interest, our scheme incurs a performance penalty of less than 5%.« less
Kinetic energy classification and smoothing for compact B-spline basis sets in quantum Monte Carlo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krogel, Jaron T.; Reboredo, Fernando A.
Quantum Monte Carlo calculations of defect properties of transition metal oxides have become feasible in recent years due to increases in computing power. As the system size has grown, availability of on-node memory has become a limiting factor. Saving memory while minimizing computational cost is now a priority. The main growth in memory demand stems from the B-spline representation of the single particle orbitals, especially for heavier elements such as transition metals where semi-core states are present. Despite the associated memory costs, splines are computationally efficient. In this paper, we explore alternatives to reduce the memory usage of splined orbitalsmore » without significantly affecting numerical fidelity or computational efficiency. We make use of the kinetic energy operator to both classify and smooth the occupied set of orbitals prior to splining. By using a partitioning scheme based on the per-orbital kinetic energy distributions, we show that memory savings of about 50% is possible for select transition metal oxide systems. Finally, for production supercells of practical interest, our scheme incurs a performance penalty of less than 5%.« less
Kinetic energy classification and smoothing for compact B-spline basis sets in quantum Monte Carlo
NASA Astrophysics Data System (ADS)
Krogel, Jaron T.; Reboredo, Fernando A.
2018-01-01
Quantum Monte Carlo calculations of defect properties of transition metal oxides have become feasible in recent years due to increases in computing power. As the system size has grown, availability of on-node memory has become a limiting factor. Saving memory while minimizing computational cost is now a priority. The main growth in memory demand stems from the B-spline representation of the single particle orbitals, especially for heavier elements such as transition metals where semi-core states are present. Despite the associated memory costs, splines are computationally efficient. In this work, we explore alternatives to reduce the memory usage of splined orbitals without significantly affecting numerical fidelity or computational efficiency. We make use of the kinetic energy operator to both classify and smooth the occupied set of orbitals prior to splining. By using a partitioning scheme based on the per-orbital kinetic energy distributions, we show that memory savings of about 50% is possible for select transition metal oxide systems. For production supercells of practical interest, our scheme incurs a performance penalty of less than 5%.
Kranenburg, Hendrikus A; Lakke, Sandra E; Schmitt, Maarten A; Van der Schans, Cees P
2017-12-01
To obtain consensus-based agreement on a classification system of adverse events (AE) following cervical spinal manipulation. The classification system should be comprised of clear definitions, include patients' and clinicians' perspectives, and have an acceptable number of categories. Design : A three-round Delphi study. Participants : Thirty Dutch participants (medical specialists, manual therapists, and patients) participated in an online survey. Procedure : Participants inventoried AE and were asked about their preferences for either a three- or a four-category classification system. The identified AE were classified by two analysts following the International Classification of Functioning, Disability and Health (ICF), and the International Classification of Diseases and Related Health Problems (ICD-10). Participants were asked to classify the severity for all AE in relation to the time duration. Consensus occurred in a three-category classification system. There was strong consensus for 16 AE in all severities (no, minor, and major AE) and all three time durations [hours, days, weeks]. The 16 AE included anxiety, flushing, skin rash, fainting, dizziness, coma, altered sensation, muscle tenderness, pain, increased pain during movement, radiating pain, dislocation, fracture, transient ischemic attack, stroke, and death. Mild to strong consensus was reached for 13 AE. A consensus-based classification system of AE is established which includes patients' and clinicians' perspectives and has three categories. The classification comprises a precise description of potential AE in accordance with internationally accepted classifications. After international validation, clinicians and researchers may use this AE classification system to report AE in clinical practice and research.
Relating Risk and Reliability Predictions to Design and Development Choices
NASA Technical Reports Server (NTRS)
Feather, Martin S.; Cornford, Steven L.
2006-01-01
In this context there are many possible assurance activities. Some focus on the prevention of defects - for example, up-front planning, adoption of design standards, configuration management, training, etc. Others focus on the detection of defects - either to detect latent defects in a system (and so be able to correct them before actual deployment of the system), or to increase confidence that such defects are not present. For example, a wide gamut of reviews, design walkthroughs, tests, inspections, analyses, etc. can be applied to systems and their components.
van Doorn, Sascha C; Hazewinkel, Y; East, James E; van Leerdam, Monique E; Rastogi, Amit; Pellisé, Maria; Sanduleanu-Dascalescu, Silvia; Bastiaansen, Barbara A J; Fockens, Paul; Dekker, Evelien
2015-01-01
The Paris classification is an international classification system for describing polyp morphology. Thus far, the validity and reproducibility of this classification have not been assessed. We aimed to determine the interobserver agreement for the Paris classification among seven Western expert endoscopists. A total of 85 short endoscopic video clips depicting polyps were created and assessed by seven expert endoscopists according to the Paris classification. After a digital training module, the same 85 polyps were assessed again. We calculated the interobserver agreement with a Fleiss kappa and as the proportion of pairwise agreement. The interobserver agreement of the Paris classification among seven experts was moderate with a Fleiss kappa of 0.42 and a mean pairwise agreement of 67%. The proportion of lesions assessed as "flat" by the experts ranged between 13 and 40% (P<0.001). After the digital training, the interobserver agreement did not change (kappa 0.38, pairwise agreement 60%). Our study is the first to validate the Paris classification for polyp morphology. We demonstrated only a moderate interobserver agreement among international Western experts for this classification system. Our data suggest that, in its current version, the use of this classification system in daily practice is questionable and it is unsuitable for comparative endoscopic research. We therefore suggest introduction of a simplification of the classification system.
5 CFR 9701.222 - Reconsideration of classification decisions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.222...
5 CFR 9701.222 - Reconsideration of classification decisions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.222...
5 CFR 9701.222 - Reconsideration of classification decisions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.222...
5 CFR 9701.222 - Reconsideration of classification decisions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Classification Classification Process § 9701.222...
Atzei, A; Luchetti, R; Garagnani, L
2017-05-01
The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.
Bias and design in software specifications
NASA Technical Reports Server (NTRS)
Straub, Pablo A.; Zelkowitz, Marvin V.
1990-01-01
Implementation bias in a specification is an arbitrary constraint in the solution space. Presented here is a model of bias in software specifications. Bias is defined in terms of the specification process and a classification of the attributes of the software product. Our definition of bias provides insight into both the origin and the consequences of bias. It also shows that bias is relative and essentially unavoidable. Finally, we describe current work on defining a measure of bias, formalizing our model, and relating bias to software defects.
MUSIC imaging method for electromagnetic inspection of composite multi-layers
NASA Astrophysics Data System (ADS)
Rodeghiero, Giacomo; Ding, Ping-Ping; Zhong, Yu; Lambert, Marc; Lesselier, Dominique
2015-03-01
A first-order asymptotic formulation of the electric field scattered by a small inclusion (with respect to the wavelength in dielectric regime or to the skin depth in conductive regime) embedded in composite material is given. It is validated by comparison with results obtained using a Method of Moments (MoM). A non-iterative MUltiple SIgnal Classification (MUSIC) imaging method is utilized in the same configuration to locate the position of small defects. The effectiveness of the imaging algorithm is illustrated through some numerical examples.
Maternal caffeine consumption and risk of cardiovascular malformations.
Browne, Marilyn L; Bell, Erin M; Druschel, Charlotte M; Gensburg, Lenore J; Mitchell, Allen A; Lin, Angela E; Romitti, Paul A; Correa, Adolfo
2007-07-01
The physiologic effects and common use of caffeine during pregnancy call for examination of maternal caffeine consumption and risk of birth defects. Epidemiologic studies have yielded mixed results, but such studies have grouped etiologically different defects and have not evaluated effect modification. The large sample size and precise case classification of the National Birth Defects Prevention Study allowed us to examine caffeine consumption and specific cardiovascular malformation (CVM) case groups. We studied consumption of caffeinated coffee, tea, soda, and chocolate to estimate total caffeine intake and separately examined exposure to each caffeinated beverage. Smoking, alcohol, vasoactive medications, folic acid supplement use, and infant gender were evaluated for effect modification. Maternal interview reports for 4,196 CVM case infants overall and 3,957 control infants were analyzed. We did not identify any significant positive associations between maternal caffeine consumption and CVMs. For tetralogy of Fallot, nonsignificant elevations in risk were observed for moderate (but not high) caffeine intake overall and among nonsmokers (ORs of 1.3 to 1.5). Risk estimates for both smoking and consuming caffeine were less than the sum of the excess risks for each exposure. We observed an inverse trend between coffee intake and risk of atrial septal defect; however, this single significant pattern of association might have been a chance finding. Our study found no evidence for an appreciable teratogenic effect of caffeine with regard to CVMs. (c) 2007 Wiley-Liss, Inc.
Risk-informed radioactive waste classification and reclassification.
Croff, Allen G
2006-11-01
Radioactive waste classification systems have been developed to allow wastes having similar hazards to be grouped for purposes of storage, treatment, packaging, transportation, and/or disposal. As recommended in the National Council on Radiation Protection and Measurements' Report No. 139, Risk-Based Classification of Radioactive and Hazardous Chemical Wastes, a preferred classification system would be based primarily on the health risks to the public that arise from waste disposal and secondarily on other attributes such as the near-term practicalities of managing a waste, i.e., the waste classification system would be risk informed. The current U.S. radioactive waste classification system is not risk informed because key definitions--especially that of high-level waste--are based on the source of the waste instead of its inherent characteristics related to risk. A second important reason for concluding the existing U.S. radioactive waste classification system is not risk informed is there are no general principles or provisions for exempting materials from being classified as radioactive waste which would then allow management without regard to its radioactivity. This paper elaborates the current system for classifying and reclassifying radioactive wastes in the United States, analyzes the extent to which the system is risk informed and the ramifications of its not being so, and provides observations on potential future direction of efforts to address shortcomings in the U.S. radioactive waste classification system as of 2004.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Determining North American Industry Classification System (NAICS) codes and size standards. 219.303 Section 219.303 Federal... Programs 219.303 Determining North American Industry Classification System (NAICS) codes and size standards...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Determining North American Industry Classification System (NAICS) codes and size standards. 219.303 Section 219.303 Federal... Programs 219.303 Determining North American Industry Classification System (NAICS) codes and size standards...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Determining North American Industry Classification System (NAICS) codes and size standards. 219.303 Section 219.303 Federal... Determining North American Industry Classification System (NAICS) codes and size standards. Contracting...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Determining North American Industry Classification System (NAICS) codes and size standards. 219.303 Section 219.303 Federal... Determining North American Industry Classification System (NAICS) codes and size standards. Contracting...
A two-view ultrasound CAD system for spina bifida detection using Zernike features
NASA Astrophysics Data System (ADS)
Konur, Umut; Gürgen, Fikret; Varol, Füsun
2011-03-01
In this work, we address a very specific CAD (Computer Aided Detection/Diagnosis) problem and try to detect one of the relatively common birth defects - spina bifida, in the prenatal period. To do this, fetal ultrasound images are used as the input imaging modality, which is the most convenient so far. Our approach is to decide using two particular types of views of the fetal neural tube. Transcerebellar head (i.e. brain) and transverse (axial) spine images are processed to extract features which are then used to classify healthy (normal), suspicious (probably defective) and non-decidable cases. Decisions raised by two independent classifiers may be individually treated, or if desired and data related to both modalities are available, those decisions can be combined to keep matters more secure. Even more security can be attained by using more than two modalities and base the final decision on all those potential classifiers. Our current system relies on feature extraction from images for cases (for particular patients). The first step is image preprocessing and segmentation to get rid of useless image pixels and represent the input in a more compact domain, which is hopefully more representative for good classification performance. Next, a particular type of feature extraction, which uses Zernike moments computed on either B/W or gray-scale image segments, is performed. The aim here is to obtain values for indicative markers that signal the presence of spina bifida. Markers differ depending on the image modality being used. Either shape or texture information captured by moments may propose useful features. Finally, SVM is used to train classifiers to be used as decision makers. Our experimental results show that a promising CAD system can be actualized for the specific purpose. On the other hand, the performance of such a system would highly depend on the qualities of image preprocessing, segmentation, feature extraction and comprehensiveness of image data.
Code of Federal Regulations, 2012 CFR
2012-01-01
... System biogeographic classification scheme and estuarine typologies. 921.3 Section 921.3 Commerce and... biogeographic classification scheme and estuarine typologies. (a) National Estuarine Research Reserves are... classification scheme based on regional variations in the nation's coastal zone has been developed. The...
Code of Federal Regulations, 2013 CFR
2013-01-01
... System biogeographic classification scheme and estuarine typologies. 921.3 Section 921.3 Commerce and... biogeographic classification scheme and estuarine typologies. (a) National Estuarine Research Reserves are... classification scheme based on regional variations in the nation's coastal zone has been developed. The...
Code of Federal Regulations, 2010 CFR
2010-01-01
... System biogeographic classification scheme and estuarine typologies. 921.3 Section 921.3 Commerce and... biogeographic classification scheme and estuarine typologies. (a) National Estuarine Research Reserves are... classification scheme based on regional variations in the nation's coastal zone has been developed. The...
Code of Federal Regulations, 2014 CFR
2014-01-01
... System biogeographic classification scheme and estuarine typologies. 921.3 Section 921.3 Commerce and... biogeographic classification scheme and estuarine typologies. (a) National Estuarine Research Reserves are... classification scheme based on regional variations in the nation's coastal zone has been developed. The...
Code of Federal Regulations, 2011 CFR
2011-01-01
... System biogeographic classification scheme and estuarine typologies. 921.3 Section 921.3 Commerce and... biogeographic classification scheme and estuarine typologies. (a) National Estuarine Research Reserves are... classification scheme based on regional variations in the nation's coastal zone has been developed. The...
Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya
2016-04-01
Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p < 0.05). Complication of a histological ulcer, large size of the resected specimen and long ESD procedure time were shown to be risk factors for hemorrhage of mucosal defects after ESD on second-look endoscopy by univariate analysis. Multivariate analysis indicated that only large size of the resected specimen was a risk factor. In a specimen size of >35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.
Use of Deo's classification system on rock : final report.
DOT National Transportation Integrated Search
1983-01-01
A shale from a construction site on Route 23 in Wise County, Virginia, was classified using Deo's classification system, and the usefulness of the classification system was evaluated. In addition, rock that had previously been used in the development...
Wangensteen, Arnlaug; Tol, Johannes L; Roemer, Frank W; Bahr, Roald; Dijkstra, H Paul; Crema, Michel D; Farooq, Abdulaziz; Guermazi, Ali
2017-04-01
To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury. Male athletes (n=40) with clinical diagnosis of acute hamstring injury and MRI ≤5days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated. We observed 'substantial' to 'almost perfect' intra- (κ range 0.65-1.00) and interrater reliability (κ range 0.77-1.00) with percentage agreement 83-100% and 88-100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range -0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories. The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated 'substantial' to 'almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Valach, J.; Cacciotti, R.; Kuneš, P.; ČerÅanský, M.; Bláha, J.
2012-04-01
The paper presents a project aiming to develop a knowledge-based system for documentation and analysis of defects of cultural heritage objects and monuments. The MONDIS information system concentrates knowledge on damage of immovable structures due to various causes, and preventive/remedial actions performed to protect/repair them, where possible. The currently built system is to provide for understanding of causal relationships between a defect, materials, external load, and environment of built object. Foundation for the knowledge-based system will be the systemized and formalized knowledge on defects and their mitigation acquired in the process of analysis of a representative set of cases documented in the past. On the basis of design comparability, used technologies, materials and the nature of the external forces and surroundings, the developed software system has the capacity to indicate the most likely risks of new defect occurrence or the extension of the existing ones. The system will also allow for a comparison of the actual failure with similar cases documented and will propose a suitable technical intervention plan. The system will provide conservationists, administrators and owners of historical objects with a toolkit for defect documentation for their objects. Also, advanced artificial intelligence methods will offer accumulated knowledge to users and will also enable them to get oriented in relevant techniques of preventive interventions and reconstructions based on similarity with their case.
Siskind, Dan; Harris, Meredith; Pirkis, Jane; Whiteford, Harvey
2013-06-01
A lack of definitional clarity in supported accommodation and the absence of a widely accepted system for classifying supported accommodation models creates barriers to service planning and evaluation. We undertook a systematic review of existing supported accommodation classification systems. Using a structured system for qualitative data analysis, we reviewed the stratification features in these classification systems, identified the key elements of supported accommodation and arranged them into domains and dimensions to create a new taxonomy. The existing classification systems were mapped onto the new taxonomy to verify the domains and dimensions. Existing classification systems used either a service-level characteristic or programmatic approach. We proposed a taxonomy based around four domains: duration of tenure; patient characteristics; housing characteristics; and service characteristics. All of the domains in the taxonomy were drawn from the existing classification structures; however, none of the existing classification structures covered all of the domains in the taxonomy. Existing classification systems are regionally based, limited in scope and lack flexibility. A domains-based taxonomy can allow more accurate description of supported accommodation services, aid in identifying the service elements likely to improve outcomes for specific patient populations, and assist in service planning.
Krifter, R M; Zweiger, C; Lick-Schiffer, W; Mattiassich, G; Schüller-Weidekamm, C; Radl, R
2013-03-01
Imaging for shoulder surgery varies a lot nowadays. Advantages and disadvantages of possible imaging methods according to the pathology and treatment options are described. Digital projection radiography in 3 planes, ultrasonography, MRI, CT scanning and scintigrams. Special axial view to visualize the glenoid situation, as well as 3-D CT scanning for larger defects and classification. Imaging of the glenoid situation, the version and erosion in axial view x-ray is mandatory to plan and control glenoid replacement. Useful application of imaging methods for the daily routine of orthopedic surgeons. Digital 3 plane x-ray imaging in arthroplasty surgery is the minimum requirement. For rotator cuff lesions ultrasonography is good. In order to gain information on fatty infiltration of rotator muscles MRI is needed as well as for intra-articular lesions. For bony defects CT and reconstruction 3-D are recommended.
Propeller Flaps: A Review of Indications, Technique, and Results
D'Arpa, Salvatore; Toia, Francesca; Pirrello, Roberto; Moschella, Francesco; Cordova, Adriana
2014-01-01
In the last years, propeller flaps have become an appealing option for coverage of a large range of defects. Besides having a more reliable vascular pedicle than traditional flap, propeller flaps allow for great freedom in design and for wide mobilization that extend the possibility of reconstructing difficult wounds with local tissues and minimal donor-site morbidity. They also allow one-stage reconstruction of defects that usually require multiple procedures. Harvesting of a propeller flap requires accurate patient selection, preoperative planning, and dissection technique. Complication rate can be kept low, provided that potential problems are prevented, promptly recognized, and adequately treated. This paper reviews current knowledge on propeller flaps. Definition, classification, and indications in the different body regions are discussed based on a review of the literature and on the authors' experience. Details about surgical technique are provided, together with tips to avoid and manage complications. PMID:24971367
On civil engineering disasters and their mitigation
NASA Astrophysics Data System (ADS)
Xie, Lili; Qu, Zhe
2018-01-01
Civil engineering works such as buildings and infrastructure are the carriers of human civilization. They are, however, also the origins of various types of disasters, which are referred to in this paper as civil engineering disasters. This paper presents the concept of civil engineering disasters, their characteristics, classification, causes, and mitigation technologies. Civil engineering disasters are caused primarily by civil engineering defects, which are usually attributed to improper selection of construction site, hazard assessment, design and construction, occupancy, and maintenance. From this viewpoint, many so-called natural disasters such as earthquakes, strong winds, floods, landslides, and debris flows are substantially due to civil engineering defects rather than the actual natural hazards. Civil engineering disasters occur frequently and globally and are the most closely related to human beings among all disasters. This paper emphasizes that such disasters can be mitigated mainly through civil engineering measures, and outlines the related objectives and scientific and technological challenges.
Defect Inspection of Flip Chip Solder Bumps Using an Ultrasonic Transducer
Su, Lei; Shi, Tielin; Xu, Zhensong; Lu, Xiangning; Liao, Guanglan
2013-01-01
Surface mount technology has spurred a rapid decrease in the size of electronic packages, where solder bump inspection of surface mount packages is crucial in the electronics manufacturing industry. In this study we demonstrate the feasibility of using a 230 MHz ultrasonic transducer for nondestructive flip chip testing. The reflected time domain signal was captured when the transducer scanning the flip chip, and the image of the flip chip was generated by scanning acoustic microscopy. Normalized cross-correlation was used to locate the center of solder bumps for segmenting the flip chip image. Then five features were extracted from the signals and images. The support vector machine was adopted to process the five features for classification and recognition. The results show the feasibility of this approach with high recognition rate, proving that defect inspection of flip chip solder bumps using the ultrasonic transducer has high potential in microelectronics packaging.
Primary disorders of the lymphatic vessels--a unified concept.
Levine, C
1989-03-01
Congenital defects of lymphatics constitute a spectrum of disorders that may manifest with a variety of clinical presentations including lymphedema, chylous effusions, lymphangiomatous malformations with cystic masses and localized gigantism, and intestinal lymphangiectasia with malabsorption. These entities constitute a relatively rare group of disorders, the origin of which remains somewhat controversial, but in some it appears to be due to early lymphatic obstruction. Five cases are described, which demonstrate the anatomical pathology of these entities. A classification and description of the defects is also presented. An attempt is made to present a unified theory of origin for this seemingly diverse group of diseases. While these entities may be challenging from a diagnostic and therapeutic standpoint, a wide variety of imaging modalities, which includes lymphography, computed tomography scanning, and ultrasound, may be used to diagnose the extent and internal structural characteristics of the abnormalities.
Discrete elastic model for two-dimensional melting.
Lansac, Yves; Glaser, Matthew A; Clark, Noel A
2006-04-01
We present a network model for the study of melting and liquid structure in two dimensions, the first in which the presence and energy of topological defects (dislocations and disclinations) and of geometrical defects (elemental voids) can be independently controlled. Interparticle interaction is via harmonic springs and control is achieved by Monte Carlo moves which springs can either be orientationally "flipped" between particles to generate topological defects, or can be "popped" in force-free shape, to generate geometrical defects. With the geometrical defects suppressed the transition to the liquid phase occurs via disclination unbinding, as described by the Kosterlitz-Thouless-Halperin-Nelson-Young model and found in soft potential two-dimensional (2D) systems, such as the dipole-dipole potential [H. H. von Grünberg, Phys. Rev. Lett. 93, 255703 (2004)]. By contrast, with topological defects suppressed, a disordering transition, the Glaser-Clark condensation of geometrical defects [M. A. Glaser and N. A. Clark, Adv. Chem. Phys. 83, 543 (1993); M. A. Glaser, (Springer-Verlag, Berlin, 1990), Vol. 52, p. 141], produces a state that accurately characterizes the local liquid structure and first-order melting observed in hard-potential 2D systems, such as hard disk and the Weeks-Chandler-Andersen (WCA) potentials (M. A. Glaser and co-workers, see above). Thus both the geometrical and topological defect systems play a role in melting. The present work introduces a system in which the relative roles of topological and geometrical defects and their interactions can be explored. We perform Monte Carlo simulations of this model in the isobaric-isothermal ensemble, and present the phase diagram as well as various thermodynamic, statistical, and structural quantities as a function of the relative populations of geometrical and topological defects. The model exhibits a rich phase behavior including hexagonal and square crystals, expanded crystal, dodecagonal quasicrystal, and isotropic liquid phases. In this system the geometrical defects effectively control the melting, reducing the solid-liquid transition temperature by a factor of relative to the topological-only case. The local structure of the dense liquid has been investigated and the results are compared to that from simulations of WCA systems.
A Model Assessment and Classification System for Men and Women in Correctional Institutions.
ERIC Educational Resources Information Center
Hellervik, Lowell W.; And Others
The report describes a manpower assessment and classification system for criminal offenders directed towards making practical training and job classification decisions. The model is not concerned with custody classifications except as they affect occupational/training possibilities. The model combines traditional procedures of vocational…
Nonequilibrium Steady State Generated by a Moving Defect: The Supersonic Threshold
NASA Astrophysics Data System (ADS)
Bastianello, Alvise; De Luca, Andrea
2018-02-01
We consider the dynamics of a system of free fermions on a 1D lattice in the presence of a defect moving at constant velocity. The defect has the form of a localized time-dependent variation of the chemical potential and induces at long times a nonequilibrium steady state (NESS), which spreads around the defect. We present a general formulation that allows recasting the time-dependent protocol in a scattering problem on a static potential. We obtain a complete characterization of the NESS. In particular, we show a strong dependence on the defect velocity and the existence of a sharp threshold when such velocity exceeds the speed of sound. Beyond this value, the NESS is not produced and, remarkably, the defect travels without significantly perturbing the system. We present an exact solution for a δ -like defect traveling with an arbitrary velocity and we develop a semiclassical approximation that provides accurate results for smooth defects.
Aksungur, N; Korkut, E
2018-05-24
We read Atamanalp classification, treatment algorithm and prognosis-estimating systems for sigmoid volvulus (SV) and ileosigmoid knotting (ISK) in Colorectal Disease [1,2]. Our comments relate to necessity and utility of these new classification systems. Classification or staging systems are generally used in malignant or premalignant pathologies such as colorectal cancers [3] or polyps [4]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.